🇵🇱 Powiatowa Stacja Sanitarno-Epidemiologiczna PL

PCA AB 611 • Starogard Gdański, Poland • 31 methods

Water & wastewaterMicrobiology

Powiatowa Stacja Sanitarno-Epidemiologiczna is a laboratory accredited by PCA under number AB 611 (Starogard Gdański, Poland). Its accreditation scope covers 31 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Swimming pool water, Water, water intended for human consumption, swimming pool water, Bathing water. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 611
  • Methods in scope: 31
  • Types of test objects: 6
  • Techniques used: 11
  • City: Starogard Gdański, Poland
Accreditation number
AB 611
Accreditation body
PCA
Address
w Starogardzie Gdańskim, ul. Kanałowa 5, 83-200 Starogard Gdański
City
Starogard Gdański, Poland

What this laboratory tests (6)

Analytical techniques used (11)

Laboratory sections (2)

Laboratory locations

Certificate information

Issue date
25.05.2026
Issue no.
22

Accreditation scope — test methods (31)

No. Test object Methodology / Parameters Technique Reference document
Laboratory Division; Environmental Testing Laboratory
1 Water, water intended for human consumption Electrical conductivity
Range (100 – 5000) μS/cm
Conductometric method PN-EN 27888:1999
2 Water, water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (6,0 – 800) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
3 Water, water intended for human consumption Colour
Range (2,0 – 40) mg/l Pt
Spectrophotometric method PB_LS_02 edycja 4 z dnia 16.01.2012 r.
4 Water, water intended for human consumption Ammonium ion concentration
Range (0,20 – 4,0) mg/I
Spectrophotometric method PN-C-04576-4:1994
5 Water, water intended for human consumption Nitrite concentration
Range (0,013 – 0,19) mg/I
Spectrophotometric method PN-EN 26777:1999
6 Water, water intended for human consumption Total iron concentration
Range (30 – 4000) μg/I
Spectrophotometric method PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06
7 Water, water intended for human consumption Chloride concentration
Range (6,5 – 350,0) mg/I
Titrimetric method PB_LS_03 edycja 1 z dnia 06.03.2009 r.
8 Water, water intended for human consumption Manganese concentration
Range (10 – 200) μg/I
Spectrophotometric method PB_LS_01 edycja 2 z dnia 24.02.2017r.
9 Water, water intended for human consumption Calcium concentration
Range (2,0 – 100) mg/l
Titrimetric method PN-ISO 6058:1999
10 Water, water intended for human consumption Magnesium concentration (calculated) PN-C 04554-4:1999 zał. A
11 Water, water intended for human consumption, swimming pool water pH
Range 4,0 – 10,0
Potentiometric method PB_LS_04 edycja 4 z dnia 24.02.2017r.
12 Water, water intended for human consumption, swimming pool water Turbidity
Range (0,10 – 20) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
13 Water, water intended for human consumption, swimming pool water Nitrate concentration
Range (0,20 – 50,0) mg/I
Spectrophotometric method PN-82/C-04576-08
14 Water, water intended for human consumption, swimming pool water Permanganate index
Range (1,0 - 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
15 Swimming pool water Oxidation-reduction (redox) potential at an Ag/AgCl 3,5 mol/l KCl electrode
Range (200 - 900) mV
Potentiometric method PB_LS_09 edycja 2 z dnia 03.03.2022r.
16 Swimming pool water Free and total chlorine concentration
Range (0,10 – 5,0) mg/l
Colorimetric method PB_LS_10 edycja 2 z dnia 14.02.2025r.
17 Swimming pool water Combined chlorine concentration (calculated) PB_LS_10 edycja 2 z dnia 14.02.2025r.
18 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
19 Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
20 Water, water intended for human consumption Total count of microorganisms on nutrient agar at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004
21 Water, water intended for human consumption Total count of microorganisms on nutrient agar at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004
22 Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
23 Water, water intended for human consumption Count of bacteria of the genus Legionella
Matrix A: Procedure 5 (medium A) Procedure 7 (medium C-GVPC) Matrix B Procedure 7 (medium C-GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 / Ap1:2019-12
24 Water, water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
25 Bathing water Most probable number of Escherichia coli
Range od 15 NPL/100 ml
Miniaturized method, MPN PN-EN ISO 9308-3:2002
26 Swimming pool water Count of bacteria of the genus Legionella
Matrix B Procedure 7 (medium C-GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 / Ap1:2019-12
27 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12, | PN-EN ISO 9308-1:2014-12 /A1:2017-04
28 Swimming pool water Total count of microorganisms on nutrient agar at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004
29 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
Laboratory Division; Bacteriology Laboratory
30 Human material: Faeces, rectal swab Presence of Salmonella spp. and Shigella spp., Presence of Salmonella Enteritidis, Salmonella Typhimurium Culture method with biochemical and serological confirmation PB_LB_01 edycja 5 z dnia 15.01.2019 r. | na podstawie wydawnictw metodycznych PZH
31 Biological indicators for sterilization efficacy control (sporal S, ampoule test) Presence of the indicator microorganism (Geobacillus stearothermophilus and Bacillus atrophaeus) Culture method PB_LB_02 edycja 2 z dnia 15.01.2019 r. | na podstawie instrukcji producenta testów

Reference standards (30)

PB_LB_01 edycja 5 z dnia 15.01.2019 r.
PB_LB_02 edycja 2 z dnia 15.01.2019 r.
PB_LS_01 edycja 2 z dnia 24.02.2017r.
PB_LS_02 edycja 4 z dnia 16.01.2012 r.
PB_LS_03 edycja 1 z dnia 06.03.2009 r.
PB_LS_04 edycja 4 z dnia 24.02.2017r.
PB_LS_09 edycja 2 z dnia 03.03.2022r.
PB_LS_10 edycja 2 z dnia 14.02.2025r.
PN-82/C-04576-08
PN-C 04554-4:1999 zał. A
PN-C-04576-4:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 11731:2017-08
PN-EN ISO 11731:2017-08 / Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12 /A1:2017-04
PN-EN ISO 9308-1:2014-12,
PN-EN ISO 9308-3:2002
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001
PN-ISO 6332:2001/Ap1:2016-06
na podstawie instrukcji producenta testów
na podstawie wydawnictw metodycznych PZH

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20611