🇵🇱 ASPEL S.A. PL
Electronics & EMCConstruction
ASPEL S.A. is a laboratory accredited by PCA under number AB 1604 (Zabierzów, Poland). Its accreditation scope covers 36 test methods in the following areas: Electronics & EMC, Construction. Test objects include: Medical electrical equipment, Electrical, electronic and medical equipment, Electrical and electronic equipment, Industrial, scientific and medical equipment.
At a glance
- Accreditation number: PCA AB 1604
- Methods in scope: 36
- Types of test objects: 8
- City: Zabierzów, Poland
- Accreditation number
- AB 1604
- Accreditation body
- PCA
- Address
- CENTRALNE LABORATORIUM APARATURY MEDYCZNEJ CELAMED, Os. Henryka Sienkiewicza 33, 32-080 Zabierzów
- City
- Zabierzów, Poland
What this laboratory tests (8)
- Medical electrical equipment — 17 methods
- Electrical, electronic and medical equipment — 8 methods
- Electrical and electronic equipment — 3 methods
- Industrial, scientific and medical equipment — 2 methods
- Information technology equipment — 2 methods
- Multimedia equipment — 2 methods
- Medical electrical equipment - electrocardiographs (limitation of the dimensions of the tested object to: (540x540x750) mm) — 1 method
- Medical electrical equipment - electroencephalographs — 1 method
Accreditation scope — test methods (36)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Medical electrical equipment | Power consumption Measuring range: up to 3 kW | PN-EN 60601-1:2011 PN-EN 60601-1/A11:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A12:2014-12 PN-EN 60601-1:2011/A2:2022-03 | ||
| 2 | Medical electrical equipment | Durability of marking | |||
| 3 | Medical electrical equipment | Legibility of marking | |||
| 4 | Medical electrical equipment | Residual voltage Measurement range: up to 1 kV | |||
| 5 | Medical electrical equipment | Leakage currents: earth leakage current Range: (0 – 8000) μA touch leakage current Range: (0 – 8000) μA patient leakage current Range: (0 – 8000) μA patient auxiliary current Range: (0 – 8000) μA patient leakage current (mains voltage on the applied part) Range: (0 – 8000) μA | |||
| 6 | Medical electrical equipment | Electric strength of the insulation Range: (0 – 5) kV AC | |||
| 7 | Medical electrical equipment | Resistance to heat Range: (40 – 150) °C | |||
| 8 | Medical electrical equipment | Creepage distances and clearances | |||
| 9 | Medical electrical equipment | Gaps of trapping zones | |||
| 10 | Medical electrical equipment | Instability of the appliance in the transport position | |||
| 11 | Medical electrical equipment | Instability of the appliance other than in transport | |||
| 12 | Medical electrical equipment | Instability due to horizontal and vertical forces | |||
| 13 | Medical electrical equipment | Force required to set the equipment in motion | |||
| 14 | Medical electrical equipment | Ability of the device to pass over a threshold | |||
| 15 | Medical electrical equipment | Enclosure stiffness (pressure test) Impact resistance Free-fall resistance Ability to: pass over a protruding threshold, descend from a step, withstand the device striking a door frame, | |||
| 16 | Medical electrical equipment | Interruptions in the continuity of the power supply | |||
| 17 | Medical electrical equipment | Humidity preconditioning Temperature range in climatic mode: (20 – 32) °C Humidity range in climatic mode: 98% ± 3% | |||
| 18 | Medical electrical equipment - electroencephalographs | Defibrillation pulse withstand Multichannel crosstalk Input impedance Range and bandwidth of transmitted frequencies | PN-EN 60601-2-26:2015-09 | ||
| 19 | Medical electrical equipment - electrocardiographs (limitation of the dimensions of the tested object to: (540x540x750) mm) | Defibrillation pulse withstand Baseline recovery time Input impedance and lead network impedance Reproduction of the calibration voltage Gain stability Gain accuracy Common mode rejection Overload withstand Baseline (thermal drift, stability, noise level, recording speed and trace width, channel crosstalk, sensitivity/effect on the baseline) Frequency response Linearity and dynamic range Response to a minimum signal Recording speed Use with a cardiac pacemaker (signal distortion, visibility of pacemaker pulses) | PN-EN 60601-2-25:2004 PN-EN 60601-2-47:2015-09 PN-EN 60601-2-51:2005 PN-EN 60601-2-25:2016-01 | ||
| 20 | Electrical, electronic and medical equipment | Immunity to voltage dips, short interruptions and voltage variations Range: 0%U , 40%U , 70%U , Ext T T T | PN-EN 61000-4-11:2020-11 | ||
| 21 | Electrical, electronic and medical equipment | Immunity to electrostatic discharge contact up to 9 kV air up to 16,5 kV | PN-EN 61000-4-2:2011 | ||
| 22 | Electrical, electronic and medical equipment | Immunity to surges Range: (0,2 – 4,4) kV | PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5:2014- 10/A1:2018-01 z wyłączeniem badań szybkich linii telekomunikacyjnych | ||
| 23 | Electrical, electronic and medical equipment | Immunity to electrical fast transient/burst Range: (0,2 – 4,4) kV | PN-EN 61000-4-4:2013-05 z wyłączeniem punktu 6.4 | ||
| 24 | Electrical, electronic and medical equipment | Immunity to power frequency magnetic field Range: (0,1 – 40) A/m | PN-EN 61000-4-8:2010 | ||
| 25 | Electrical, electronic and medical equipment | Immunity to pulse magnetic field Range: (100 – 2200) A/m | PN-EN 61000-4-9:1998 + A1:2003 | ||
| 26 | Electrical, electronic and medical equipment | Immunity to conducted disturbances induced by radio-frequency fields: Range:150 kHz – 230 MHz | PN-EN IEC 61000-4-6:2024-03 | ||
| 27 | Electrical, electronic and medical equipment | Immunity to radiated radio-frequency electromagnetic field: Range: 80 MHz – 3 GHz, disturbance level up to 10 V/m | PN-EN 61000-4-3:2021-06 | ||
| 28 | Electrical and electronic equipment | Emission of electromagnetic disturbances | PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 | ||
| 29 | Electrical and electronic equipment | Current harmonics Range: (0 – 16) A, n = 1, 2, ..., 50 | PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-2:2019-04/A1:2021-08 PN-EN IEC 61000-3-2:2019-04/A2:2024-12 | ||
| 30 | Electrical and electronic equipment | Voltage changes, voltage fluctuations and flicker in public low-voltage supply systems | PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019-10 PN-EN 61000-3-3:2013-10/A2:2022-04 | ||
| 31 | Industrial, scientific and medical equipment | Continuous radio disturbance voltage on mains supply leads Range: 150 kHz – 30 MHz | PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 | ||
| 32 | Industrial, scientific and medical equipment | Electromagnetic field strength Range: 30 MHz – 6 GHz measurement distance 3 m | PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 | ||
| 33 | Information technology equipment | Continuous radio disturbance voltage on mains supply leads Range: 150 kHz – 30 MHz | PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 | ||
| 34 | Information technology equipment | Electromagnetic field strength Range: 30 MHz – 6 GHz measurement distance 3 m | PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 | ||
| 35 | Multimedia equipment | Continuous radio disturbance voltage on mains supply leads Range: 150 kHz – 30 MHz | PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 | ||
| 36 | Multimedia equipment | Electromagnetic field strength Range: 30 MHz – 6 GHz measurement distance 3 m | PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 | ||
Reference standards (20)
PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12
PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12
PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03
PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05
PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03
PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08
PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05
PN-EN 60601-1:2011 PN-EN 60601-1/A11:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A12:2014-12 PN-EN 60601-1:2011/A2:2022-03
PN-EN 60601-2-25:2004 PN-EN 60601-2-47:2015-09 PN-EN 60601-2-51:2005 PN-EN 60601-2-25:2016-01
PN-EN 60601-2-26:2015-09
PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019-10 PN-EN 61000-3-3:2013-10/A2:2022-04
PN-EN 61000-4-11:2020-11
PN-EN 61000-4-2:2011
PN-EN 61000-4-3:2021-06
PN-EN 61000-4-4:2013-05 z wyłączeniem punktu 6.4
PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5:2014- 10/A1:2018-01 z wyłączeniem badań szybkich linii telekomunikacyjnych
PN-EN 61000-4-8:2010
PN-EN 61000-4-9:1998 + A1:2003
PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-2:2019-04/A1:2021-08 PN-EN IEC 61000-3-2:2019-04/A2:2024-12
PN-EN IEC 61000-4-6:2024-03