{"lab":{"_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","address":"CENTRALNE LABORATORIUM APARATURY MEDYCZNEJ CELAMED, Os. Henryka Sienkiewicza 33, 32-080 Zabierzów","categories":["electronics","construction"],"city":"Zabierzów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":36,"name":"ASPEL S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1604.pdf"],"scope_summary":"","search_text":"aspel s.a. centralne laboratorium aparatury medycznej celamed, os. henryka sienkiewicza 33, 32-080 zabierzów pharma electronics metrology other environment water construction","status":"active","updated_at":"2026-03-08T14:50:44.369Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:44.369Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201604,podmiot.html","parse_date":"2026-07-17T16:19:16.120Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"E6; E14, E53; E54","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, wyposażenia medycznego, wyrobów i wyposażenia telekomunikacyjnego i wyrobów i wyposażenia elektronicznego","en":"Electric and electronic tests of electrical products and equipment, medical equipment, telecommunication products and equipment, electronic products and equipment"},{"codes":"F6; F14; F53; F54","pl":"Badania kompatybilności elektromagnetycznej wyrobów i wyposażenia elektrycznego, wyposażenia medycznego, wyrobów i wyposażenia telekomunikacyjnego i wyrobów i wyposażenia elektronicznego","en":"Electromagnetic compatibility (EMC) tests of electrical products and equipment, medical equipment, telecommunication products and equipment, electronic products and equipment"},{"codes":"J14","pl":"Badania mechaniczne wyposażenia medycznego","en":"Mechanical tests of medical equipment"},{"codes":"N14","pl":"Badania właściwości fizycznych wyposażenia medycznego","en":"Tests of physical properties of medical equipment"}],"issue":{"no":"15","date":"13.02.2026"},"map_coord":[50.114639,19.799381],"map_geo":"nominatim-city","has_en":true,"category_counts":{"other":22,"electronics":11,"construction":2,"metrology":1,"environment":1},"category_scores":{"other":13.08,"electronics":3.27,"construction":0.11,"metrology":0.03,"environment":0.03},"has_zh":true},"methods":[{"_id":"6a5a56049af9f73f382546ad","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Pobór mocy Zakres pomiarowy: do 3 kW","methodology_en":"Power consumption Measuring range: up to 3 kW","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobór mocy Zakres pomiarowy: do 3 kW","reference":"PN-EN 60601-1:2011 PN-EN 60601-1/A11:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A12:2014-12 PN-EN 60601-1:2011/A2:2022-03","norm_bases":["PN-EN 60601-1:2011 PN-EN 60601-1/A11:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A12:2014-12 PN-EN 60601-1:2011/A2:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Pobór mocy Zakres pomiarowy: do 3 kW PN-EN 60601-1:2011 PN-EN 60601-1/A11:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A12:2014-12 PN-EN 60601-1:2011/A2:2022-03 Medyczne urzadzenia elektryczne Pobor mocy Zakres pomiarowy: do 3 kW PN-EN 60601-1:2011 PN-EN 60601-1/A11:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A12:2014-12 PN-EN 60601-1:2011/A2:2022-03","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Power consumption Measuring range: up to 3 kW PN-EN 60601-1:2011 PN-EN 60601-1/A11:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A12:2014-12 PN-EN 60601-1:2011/A2:2022-03","search_zh":"医用电气设备 PN-EN 60601-1:2011 PN-EN 60601-1/A11:2011 PN-EN 60601-1:2011/A1:2014-02 PN-EN 60601-1:2011/A12:2014-12 PN-EN 60601-1:2011/A2:2022-03","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546ae","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Trwałość oznakowania","methodology_en":"Durability of marking","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość oznakowania","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Trwałość oznakowania Medyczne urzadzenia elektryczne Trwalosc oznakowania","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Durability of marking","search_zh":"医用电气设备 标识耐久性","test_object_zh":"医用电气设备","methodology_zh":"标识耐久性"},{"_id":"6a5a56049af9f73f382546af","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Czytelność oznakowania","methodology_en":"Legibility of marking","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czytelność oznakowania","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Czytelność oznakowania Medyczne urzadzenia elektryczne Czytelnosc oznakowania","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Legibility of marking","search_zh":"医用电气设备 标识的清晰度","test_object_zh":"医用电气设备","methodology_zh":"标识的清晰度"},{"_id":"6a5a56049af9f73f382546b0","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Napięcie resztkowe Zakres pomiarowy: do 1 kV","methodology_en":"Residual voltage Measurement range: up to 1 kV","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie resztkowe Zakres pomiarowy: do 1 kV","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Napięcie resztkowe Zakres pomiarowy: do 1 kV Medyczne urzadzenia elektryczne Napiecie resztkowe Zakres pomiarowy: do 1 kV","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Residual voltage Measurement range: up to 1 kV","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546b1","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Prądy upływu:  prąd upływu uziomowy Zakres: (0 – 8000) μA  prąd upływu dotykowy Zakres: (0 – 8000) μA  prąd upływu pacjenta Zakres: (0 – 8000) μA  prąd pomocniczy pacjenta Zakres: (0 – 8000) μA  prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej) Zakres: (0 – 8000) μA","methodology_en":"Leakage currents:  earth leakage current Range: (0 – 8000) μA  touch leakage current Range: (0 – 8000) μA  patient leakage current Range: (0 – 8000) μA  patient auxiliary current Range: (0 – 8000) μA  patient leakage current (mains voltage on the applied part) Range: (0 – 8000) μA","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Prądy upływu:  prąd upływu uziomowy Zakres: (0 – 8000) μA  prąd upływu dotykowy Zakres: (0 – 8000) μA  prąd upływu pacjenta Zakres: (0 – 8000) μA  prąd pomocniczy pacjenta Zakres: (0 – 8000) μA  prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej) Zakres: (0 – 8000) μA","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Prądy upływu:  prąd upływu uziomowy Zakres: (0 – 8000) μA  prąd upływu dotykowy Zakres: (0 – 8000) μA  prąd upływu pacjenta Zakres: (0 – 8000) μA  prąd pomocniczy pacjenta Zakres: (0 – 8000) μA  prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej) Zakres: (0 – 8000) μA Medyczne urzadzenia elektryczne Prady uplywu:  prad uplywu uziomowy Zakres: (0 – 8000) μA  prad uplywu dotykowy Zakres: (0 – 8000) μA  prad uplywu pacjenta Zakres: (0 – 8000) μA  prad pomocniczy pacjenta Zakres: (0 – 8000) μA  prad uplywu pacjenta (napiecie sieciowe na czesci aplikacyjnej) Zakres: (0 – 8000) μA","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Leakage currents:  earth leakage current Range: (0 – 8000) μA  touch leakage current Range: (0 – 8000) μA  patient leakage current Range: (0 – 8000) μA  patient auxiliary current Range: (0 – 8000) μA  patient leakage current (mains voltage on the applied part) Range: (0 – 8000) μA","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546b2","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Wytrzymałość elektryczna izolacji Zakres: (0 – 5) kV AC","methodology_en":"Electric strength of the insulation Range: (0 – 5) kV AC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna izolacji Zakres: (0 – 5) kV AC","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Wytrzymałość elektryczna izolacji Zakres: (0 – 5) kV AC Medyczne urzadzenia elektryczne Wytrzymalosc elektryczna izolacji Zakres: (0 – 5) kV AC","categories":["construction"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Electric strength of the insulation Range: (0 – 5) kV AC","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546b3","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Odporność na ciepło Zakres: (40 – 150) °C","methodology_en":"Resistance to heat Range: (40 – 150) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na ciepło Zakres: (40 – 150) °C","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Odporność na ciepło Zakres: (40 – 150) °C Medyczne urzadzenia elektryczne Odpornosc na cieplo Zakres: (40 – 150) °C","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Resistance to heat Range: (40 – 150) °C","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546b4","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Odstępy izolacyjne powierzchniowe i powietrzne","methodology_en":"Creepage distances and clearances","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odstępy izolacyjne powierzchniowe i powietrzne","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Odstępy izolacyjne powierzchniowe i powietrzne Medyczne urzadzenia elektryczne Odstepy izolacyjne powierzchniowe i powietrzne","categories":["construction"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Creepage distances and clearances","search_zh":"医用电气设备 爬电距离与电气间隙","test_object_zh":"医用电气设备","methodology_zh":"爬电距离与电气间隙"},{"_id":"6a5a56049af9f73f382546b5","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Szczeliny stref pułapkowych","methodology_en":"Gaps of trapping zones","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczeliny stref pułapkowych","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Szczeliny stref pułapkowych Medyczne urzadzenia elektryczne Szczeliny stref pulapkowych","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Gaps of trapping zones","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546b6","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Niestabilność urządzenia w pozycji transportowej","methodology_en":"Instability of the appliance in the transport position","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Niestabilność urządzenia w pozycji transportowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Niestabilność urządzenia w pozycji transportowej Medyczne urzadzenia elektryczne Niestabilnosc urzadzenia w pozycji transportowej","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Instability of the appliance in the transport position","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546b7","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Niestabilność urządzenia poza transportem","methodology_en":"Instability of the appliance other than in transport","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Niestabilność urządzenia poza transportem","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Niestabilność urządzenia poza transportem Medyczne urzadzenia elektryczne Niestabilnosc urzadzenia poza transportem","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Instability of the appliance other than in transport","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546b8","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Niestabilność w wyniku działania sił poziomych i pionowych","methodology_en":"Instability due to horizontal and vertical forces","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Niestabilność w wyniku działania sił poziomych i pionowych","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Niestabilność w wyniku działania sił poziomych i pionowych Medyczne urzadzenia elektryczne Niestabilnosc w wyniku dzialania sil poziomych i pionowych","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Instability due to horizontal and vertical forces","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546b9","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Siła umożliwiająca wprawienie w ruch urządzenia","methodology_en":"Force required to set the equipment in motion","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła umożliwiająca wprawienie w ruch urządzenia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Siła umożliwiająca wprawienie w ruch urządzenia Medyczne urzadzenia elektryczne Sila umozliwiajaca wprawienie w ruch urzadzenia","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Force required to set the equipment in motion","search_zh":"医用电气设备 使设备启动所需的力","test_object_zh":"医用电气设备","methodology_zh":"使设备启动所需的力"},{"_id":"6a5a56049af9f73f382546ba","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Zdolność urządzenia do przejazdu przez próg","methodology_en":"Ability of the device to pass over a threshold","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność urządzenia do przejazdu przez próg","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Zdolność urządzenia do przejazdu przez próg Medyczne urzadzenia elektryczne Zdolnosc urzadzenia do przejazdu przez prog","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Ability of the device to pass over a threshold","search_zh":"医用电气设备 设备越过门槛的通过能力","test_object_zh":"医用电气设备","methodology_zh":"设备越过门槛的通过能力"},{"_id":"6a5a56049af9f73f382546bb","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Sztywność obudowy (próba nacisku) Wytrzymałość na uderzenie Wytrzymałość na spadek swobodny Zdolność do:  przejazdu przez wystający próg,  zjazdu z uskoku,  uderzenia urządzenia o framugę drzwi,","methodology_en":"Enclosure stiffness (pressure test) Impact resistance Free-fall resistance Ability to:  pass over a protruding threshold,  descend from a step,  withstand the device striking a door frame,","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sztywność obudowy (próba nacisku) Wytrzymałość na uderzenie Wytrzymałość na spadek swobodny Zdolność do:  przejazdu przez wystający próg,  zjazdu z uskoku,  uderzenia urządzenia o framugę drzwi,","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Sztywność obudowy (próba nacisku) Wytrzymałość na uderzenie Wytrzymałość na spadek swobodny Zdolność do:  przejazdu przez wystający próg,  zjazdu z uskoku,  uderzenia urządzenia o framugę drzwi, Medyczne urzadzenia elektryczne Sztywnosc obudowy (proba nacisku) Wytrzymalosc na uderzenie Wytrzymalosc na spadek swobodny Zdolnosc do:  przejazdu przez wystajacy prog,  zjazdu z uskoku,  uderzenia urzadzenia o framuge drzwi,","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Enclosure stiffness (pressure test) Impact resistance Free-fall resistance Ability to:  pass over a protruding threshold,  descend from a step,  withstand the device striking a door frame,","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546bc","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Przerwy w ciągłości zasilania","methodology_en":"Interruptions in the continuity of the power supply","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przerwy w ciągłości zasilania","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Przerwy w ciągłości zasilania Medyczne urzadzenia elektryczne Przerwy w ciaglosci zasilania","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Interruptions in the continuity of the power supply","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546bd","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Wilgotnościowe stabilizowanie wstępne Zakres temperatur w trybie klimat: (20 – 32) °C Zakres wilgotności w trybie klimat: 98% ± 3%","methodology_en":"Humidity preconditioning Temperature range in climatic mode: (20 – 32) °C Humidity range in climatic mode: 98% ± 3%","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wilgotnościowe stabilizowanie wstępne Zakres temperatur w trybie klimat: (20 – 32) °C Zakres wilgotności w trybie klimat: 98% ± 3%","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Wilgotnościowe stabilizowanie wstępne Zakres temperatur w trybie klimat: (20 – 32) °C Zakres wilgotności w trybie klimat: 98% ± 3% Medyczne urzadzenia elektryczne Wilgotnosciowe stabilizowanie wstepne Zakres temperatur w trybie klimat: (20 – 32) °C Zakres wilgotnosci w trybie klimat: 98% ± 3%","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment Humidity preconditioning Temperature range in climatic mode: (20 – 32) °C Humidity range in climatic mode: 98% ± 3%","search_zh":"医用电气设备","test_object_zh":"医用电气设备"},{"_id":"6a5a56049af9f73f382546be","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne  elektroencefalografy","test_object_en":"Medical electrical equipment - electroencephalographs","methodology":"Odporność na impuls defibrylujący Przesłuch wielokanałowy Impedancja wejściowa Zakres i pasmo częstotliwości przenoszonych","methodology_en":"Defibrillation pulse withstand Multichannel crosstalk Input impedance Range and bandwidth of transmitted frequencies","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na impuls defibrylujący Przesłuch wielokanałowy Impedancja wejściowa Zakres i pasmo częstotliwości przenoszonych","reference":"PN-EN 60601-2-26:2015-09","norm_bases":["PN-EN 60601-2-26:2015-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne  elektroencefalografy Odporność na impuls defibrylujący Przesłuch wielokanałowy Impedancja wejściowa Zakres i pasmo częstotliwości przenoszonych PN-EN 60601-2-26:2015-09 Medyczne urzadzenia elektryczne  elektroencefalografy Odpornosc na impuls defibrylujacy Przesluch wielokanalowy Impedancja wejsciowa Zakres i pasmo czestotliwosci przenoszonych PN-EN 60601-2-26:2015-09","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment - electroencephalographs Defibrillation pulse withstand Multichannel crosstalk Input impedance Range and bandwidth of transmitted frequencies PN-EN 60601-2-26:2015-09"},{"_id":"6a5a56049af9f73f382546bf","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne  elektrokardiografy (ograniczenie gabarytów badanego obiektu do wymiarów: (540x540x750) mm)","test_object_en":"Medical electrical equipment - electrocardiographs (limitation of the dimensions of the tested object to: (540x540x750) mm)","methodology":"Odporność na impuls defibrylujący Czas powrotu linii odniesienia Impedancja wejściowa i impedancja sieci odprowadzeń Odtworzenie napięcia kalibracji Stabilność czułości Dokładność czułości Tłumienie sygnału wspólnego Odporność na przeciążenie Linia odniesienia (dryft termiczny, stabilność, poziom szumów, prędkość rejestracji i szerokość śladu zapisu, wzajemne oddziaływanie pomiędzy kanałami, czułość/oddziaływanie na linię odniesienia) Charakterystyka częstotliwościowa Liniowość i zakres dynamiki Reakcja na minimalny sygnał Prędkość zapisu Stosowanie z kardiostymulatorem (zniekształcenia sygnału, widoczność impulsów z kardiostymulatora)","methodology_en":"Defibrillation pulse withstand Baseline recovery time Input impedance and lead network impedance Reproduction of the calibration voltage Gain stability Gain accuracy Common mode rejection Overload withstand Baseline (thermal drift, stability, noise level, recording speed and trace width, channel crosstalk, sensitivity/effect on the baseline) Frequency response Linearity and dynamic range Response to a minimum signal Recording speed Use with a cardiac pacemaker (signal distortion, visibility of pacemaker pulses)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na impuls defibrylujący Czas powrotu linii odniesienia Impedancja wejściowa i impedancja sieci odprowadzeń Odtworzenie napięcia kalibracji Stabilność czułości Dokładność czułości Tłumienie sygnału wspólnego Odporność na przeciążenie Linia odniesienia (dryft termiczny, stabilność, poziom szumów, prędkość rejestracji i szerokość śladu zapisu, wzajemne oddziaływanie pomiędzy kanałami, czułość/oddziaływanie na linię odniesienia) Charakterystyka częstotliwościowa Liniowość i zakres dynamiki Reakcja na minimalny sygnał Prędkość zapisu Stosowanie z kardiostymulatorem (zniekształcenia sygnału, widoczność impulsów z kardiostymulatora)","reference":"PN-EN 60601-2-25:2004 PN-EN 60601-2-47:2015-09 PN-EN 60601-2-51:2005 PN-EN 60601-2-25:2016-01","norm_bases":["PN-EN 60601-2-25:2004 PN-EN 60601-2-47:2015-09 PN-EN 60601-2-51:2005 PN-EN 60601-2-25:2016-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne  elektrokardiografy (ograniczenie gabarytów badanego obiektu do wymiarów: (540x540x750) mm) Odporność na impuls defibrylujący Czas powrotu linii odniesienia Impedancja wejściowa i impedancja sieci odprowadzeń Odtworzenie napięcia kalibracji Stabilność czułości Dokładność czułości Tłumienie sygnału wspólnego Odporność na przeciążenie Linia odniesienia (dryft termiczny, stabilność, poziom szumów, prędkość rejestracji i szerokość śladu zapisu, wzajemne oddziaływanie pomiędzy kanałami, czułość/oddziaływanie na linię odniesienia) Charakterystyka częstotliwościowa Liniowość i zakres dynamiki Reakcja na minimalny sygnał Prędkość zapisu Stosowanie z kardiostymulatorem (zniekształcenia sygnału, widoczność impulsów z kardiostymulatora) PN-EN 60601-2-25:2004 PN-EN 60601-2-47:2015-09 PN-EN 60601-2-51:2005 PN-EN 60601-2-25:2016-01 Medyczne urzadzenia elektryczne  elektrokardiografy (ograniczenie gabarytow badanego obiektu do wymiarow: (540x540x750) mm) Odpornosc na impuls defibrylujacy Czas powrotu linii odniesienia Impedancja wejsciowa i impedancja sieci odprowadzen Odtworzenie napiecia kalibracji Stabilnosc czulosci Dokladnosc czulosci Tlumienie sygnalu wspolnego Odpornosc na przeciazenie Linia odniesienia (dryft termiczny, stabilnosc, poziom szumow, predkosc rejestracji i szerokosc sladu zapisu, wzajemne oddzialywanie pomiedzy kanalami, czulosc/oddzialywanie na linie odniesienia) Charakterystyka czestotliwosciowa Liniowosc i zakres dynamiki Reakcja na minimalny sygnal Predkosc zapisu Stosowanie z kardiostymulatorem (znieksztalcenia sygnalu, widocznosc impulsow z kardiostymulatora) PN-EN 60601-2-25:2004 PN-EN 60601-2-47:2015-09 PN-EN 60601-2-51:2005 PN-EN 60601-2-25:2016-01","categories":["metrology"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Medical electrical equipment - electrocardiographs (limitation of the dimensions of the tested object to: (540x540x750) mm) Defibrillation pulse withstand Baseline recovery time Input impedance and lead network impedance Reproduction of the calibration voltage Gain stability Gain accuracy Common mode rejection Overload withstand Baseline (thermal drift, stability, noise level, recording speed and trace width, channel crosstalk, sensitivity/effect on the baseline) Frequency response Linearity and dynamic range Response to a minimum signal Recording speed Use with a cardiac pacemaker (signal distortion, visibility of pacemaker pulses) PN-EN 60601-2-25:2004 PN-EN 60601-2-47:2015-09 PN-EN 60601-2-51:2005 PN-EN 60601-2-25:2016-01"},{"_id":"6a5a56049af9f73f382546c0","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne, elektroniczne i medyczne","test_object_en":"Electrical, electronic and medical equipment","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia Zakres: 0%U , 40%U , 70%U , Ext T T T","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations Range: 0%U , 40%U , 70%U , Ext T T T","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia Zakres: 0%U , 40%U , 70%U , Ext T T T","reference":"PN-EN 61000-4-11:2020-11","norm_bases":["PN-EN 61000-4-11:2020-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne, elektroniczne i medyczne Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia Zakres: 0%U , 40%U , 70%U , Ext T T T PN-EN 61000-4-11:2020-11 Urzadzenia elektryczne, elektroniczne i medyczne Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia Zakres: 0%U , 40%U , 70%U , Ext T T T PN-EN 61000-4-11:2020-11","categories":["electronics"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, electronic and medical equipment Immunity to voltage dips, short interruptions and voltage variations Range: 0%U , 40%U , 70%U , Ext T T T PN-EN 61000-4-11:2020-11","search_zh":"电气、电子与医疗设备 PN-EN 61000-4-11:2020-11","test_object_zh":"电气、电子与医疗设备"},{"_id":"6a5a56049af9f73f382546c1","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne, elektroniczne i medyczne","test_object_en":"Electrical, electronic and medical equipment","methodology":"Odporność na wyładowania elektrostatyczne  kontaktowe do 9 kV  powietrzne do 16,5 kV","methodology_en":"Immunity to electrostatic discharge  contact up to 9 kV  air up to 16,5 kV","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne  kontaktowe do 9 kV  powietrzne do 16,5 kV","reference":"PN-EN 61000-4-2:2011","norm_bases":["PN-EN 61000-4-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne, elektroniczne i medyczne Odporność na wyładowania elektrostatyczne  kontaktowe do 9 kV  powietrzne do 16,5 kV PN-EN 61000-4-2:2011 Urzadzenia elektryczne, elektroniczne i medyczne Odpornosc na wyladowania elektrostatyczne  kontaktowe do 9 kV  powietrzne do 16,5 kV PN-EN 61000-4-2:2011","categories":["electronics"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, electronic and medical equipment Immunity to electrostatic discharge  contact up to 9 kV  air up to 16,5 kV PN-EN 61000-4-2:2011","search_zh":"电气、电子与医疗设备 PN-EN 61000-4-2:2011","test_object_zh":"电气、电子与医疗设备"},{"_id":"6a5a56049af9f73f382546c2","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne, elektroniczne i medyczne","test_object_en":"Electrical, electronic and medical equipment","methodology":"Odporność na udary Zakres: (0,2 – 4,4) kV","methodology_en":"Immunity to surges Range: (0,2 – 4,4) kV","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na udary Zakres: (0,2 – 4,4) kV","reference":"PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5:2014- 10/A1:2018-01 z wyłączeniem badań szybkich linii telekomunikacyjnych","norm_bases":["PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5:2014- 10/A1:2018-01 z wyłączeniem badań szybkich linii telekomunikacyjnych"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne, elektroniczne i medyczne Odporność na udary Zakres: (0,2 – 4,4) kV PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5:2014- 10/A1:2018-01 z wyłączeniem badań szybkich linii telekomunikacyjnych Urzadzenia elektryczne, elektroniczne i medyczne Odpornosc na udary Zakres: (0,2 – 4,4) kV PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5:2014- 10/A1:2018-01 z wylaczeniem badan szybkich linii telekomunikacyjnych","categories":["electronics"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, electronic and medical equipment Immunity to surges Range: (0,2 – 4,4) kV PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5:2014- 10/A1:2018-01 z wyłączeniem badań szybkich linii telekomunikacyjnych","search_zh":"电气、电子与医疗设备 PN-EN 61000-4-5:2014-10 PN-EN 61000-4-5:2014- 10/A1:2018-01 z wyłączeniem badań szybkich linii telekomunikacyjnych","test_object_zh":"电气、电子与医疗设备"},{"_id":"6a5a56049af9f73f382546c3","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne, elektroniczne i medyczne","test_object_en":"Electrical, electronic and medical equipment","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych Zakres: (0,2 – 4,4) kV","methodology_en":"Immunity to electrical fast transient/burst Range: (0,2 – 4,4) kV","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych Zakres: (0,2 – 4,4) kV","reference":"PN-EN 61000-4-4:2013-05 z wyłączeniem punktu 6.4","norm_bases":["PN-EN 61000-4-4:2013-05 z wyłączeniem punktu 6.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne, elektroniczne i medyczne Odporność na serie szybkich elektrycznych stanów przejściowych Zakres: (0,2 – 4,4) kV PN-EN 61000-4-4:2013-05 z wyłączeniem punktu 6.4 Urzadzenia elektryczne, elektroniczne i medyczne Odpornosc na serie szybkich elektrycznych stanow przejsciowych Zakres: (0,2 – 4,4) kV PN-EN 61000-4-4:2013-05 z wylaczeniem punktu 6.4","categories":["electronics"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, electronic and medical equipment Immunity to electrical fast transient/burst Range: (0,2 – 4,4) kV PN-EN 61000-4-4:2013-05 z wyłączeniem punktu 6.4","search_zh":"电气、电子与医疗设备 PN-EN 61000-4-4:2013-05 z wyłączeniem punktu 6.4","test_object_zh":"电气、电子与医疗设备"},{"_id":"6a5a56049af9f73f382546c4","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne, elektroniczne i medyczne","test_object_en":"Electrical, electronic and medical equipment","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej Zakres: (0,1 – 40) A/m","methodology_en":"Immunity to power frequency magnetic field Range: (0,1 – 40) A/m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej Zakres: (0,1 – 40) A/m","reference":"PN-EN 61000-4-8:2010","norm_bases":["PN-EN 61000-4-8:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne, elektroniczne i medyczne Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej Zakres: (0,1 – 40) A/m PN-EN 61000-4-8:2010 Urzadzenia elektryczne, elektroniczne i medyczne Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej Zakres: (0,1 – 40) A/m PN-EN 61000-4-8:2010","categories":["electronics"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, electronic and medical equipment Immunity to power frequency magnetic field Range: (0,1 – 40) A/m PN-EN 61000-4-8:2010","search_zh":"电气、电子与医疗设备 PN-EN 61000-4-8:2010","test_object_zh":"电气、电子与医疗设备"},{"_id":"6a5a56049af9f73f382546c5","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne, elektroniczne i medyczne","test_object_en":"Electrical, electronic and medical equipment","methodology":"Odporność na impulsowe pole magnetyczne Zakres: (100 – 2200) A/m","methodology_en":"Immunity to pulse magnetic field Range: (100 – 2200) A/m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na impulsowe pole magnetyczne Zakres: (100 – 2200) A/m","reference":"PN-EN 61000-4-9:1998 + A1:2003","norm_bases":["PN-EN 61000-4-9:1998 + A1:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne, elektroniczne i medyczne Odporność na impulsowe pole magnetyczne Zakres: (100 – 2200) A/m PN-EN 61000-4-9:1998 + A1:2003 Urzadzenia elektryczne, elektroniczne i medyczne Odpornosc na impulsowe pole magnetyczne Zakres: (100 – 2200) A/m PN-EN 61000-4-9:1998 + A1:2003","categories":["electronics"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, electronic and medical equipment Immunity to pulse magnetic field Range: (100 – 2200) A/m PN-EN 61000-4-9:1998 + A1:2003","search_zh":"电气、电子与医疗设备 PN-EN 61000-4-9:1998 + A1:2003","test_object_zh":"电气、电子与医疗设备"},{"_id":"6a5a56049af9f73f382546c6","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne, elektroniczne i medyczne","test_object_en":"Electrical, electronic and medical equipment","methodology":"Odporność na zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej: Zakres:150 kHz – 230 MHz","methodology_en":"Immunity to conducted disturbances induced by radio-frequency fields: Range:150 kHz – 230 MHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej: Zakres:150 kHz – 230 MHz","reference":"PN-EN IEC 61000-4-6:2024-03","norm_bases":["PN-EN IEC 61000-4-6:2024-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne, elektroniczne i medyczne Odporność na zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej: Zakres:150 kHz – 230 MHz PN-EN IEC 61000-4-6:2024-03 Urzadzenia elektryczne, elektroniczne i medyczne Odpornosc na zaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej: Zakres:150 kHz – 230 MHz PN-EN IEC 61000-4-6:2024-03","categories":["electronics"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, electronic and medical equipment Immunity to conducted disturbances induced by radio-frequency fields: Range:150 kHz – 230 MHz PN-EN IEC 61000-4-6:2024-03","search_zh":"电气、电子与医疗设备 PN-EN IEC 61000-4-6:2024-03","test_object_zh":"电气、电子与医疗设备"},{"_id":"6a5a56049af9f73f382546c7","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne, elektroniczne i medyczne","test_object_en":"Electrical, electronic and medical equipment","methodology":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej: Zakres: 80 MHz – 3 GHz, poziom zaburzeń do 10 V/m","methodology_en":"Immunity to radiated radio-frequency electromagnetic field: Range: 80 MHz – 3 GHz, disturbance level up to 10 V/m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej: Zakres: 80 MHz – 3 GHz, poziom zaburzeń do 10 V/m","reference":"PN-EN 61000-4-3:2021-06","norm_bases":["PN-EN 61000-4-3:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne, elektroniczne i medyczne Odporność na promieniowane pole elektromagnetyczne o częstotliwości radiowej: Zakres: 80 MHz – 3 GHz, poziom zaburzeń do 10 V/m PN-EN 61000-4-3:2021-06 Urzadzenia elektryczne, elektroniczne i medyczne Odpornosc na promieniowane pole elektromagnetyczne o czestotliwosci radiowej: Zakres: 80 MHz – 3 GHz, poziom zaburzen do 10 V/m PN-EN 61000-4-3:2021-06","categories":["electronics"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, electronic and medical equipment Immunity to radiated radio-frequency electromagnetic field: Range: 80 MHz – 3 GHz, disturbance level up to 10 V/m PN-EN 61000-4-3:2021-06","search_zh":"电气、电子与医疗设备 PN-EN 61000-4-3:2021-06","test_object_zh":"电气、电子与医疗设备"},{"_id":"6a5a56049af9f73f382546c8","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Emisja zaburzeń elektromagnetycznych","methodology_en":"Emission of electromagnetic disturbances","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja zaburzeń elektromagnetycznych","reference":"PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03","norm_bases":["PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Emisja zaburzeń elektromagnetycznych PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 Urzadzenia elektryczne i elektroniczne Emisja zaburzen elektromagnetycznych PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03","categories":["environment","electronics"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment Emission of electromagnetic disturbances PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03","search_zh":"电气与电子设备 PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03","test_object_zh":"电气与电子设备"},{"_id":"6a5a56049af9f73f382546c9","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Harmoniczne prądu Zakres: (0 – 16) A, n = 1, 2, ..., 50","methodology_en":"Current harmonics Range: (0 – 16) A, n = 1, 2, ..., 50","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Harmoniczne prądu Zakres: (0 – 16) A, n = 1, 2, ..., 50","reference":"PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-2:2019-04/A1:2021-08 PN-EN IEC 61000-3-2:2019-04/A2:2024-12","norm_bases":["PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-2:2019-04/A1:2021-08 PN-EN IEC 61000-3-2:2019-04/A2:2024-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Harmoniczne prądu Zakres: (0 – 16) A, n = 1, 2, ..., 50 PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-2:2019-04/A1:2021-08 PN-EN IEC 61000-3-2:2019-04/A2:2024-12 Urzadzenia elektryczne i elektroniczne Harmoniczne pradu Zakres: (0 – 16) A, n = 1, 2, ..., 50 PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-2:2019-04/A1:2021-08 PN-EN IEC 61000-3-2:2019-04/A2:2024-12","categories":["electronics"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment Current harmonics Range: (0 – 16) A, n = 1, 2, ..., 50 PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-2:2019-04/A1:2021-08 PN-EN IEC 61000-3-2:2019-04/A2:2024-12","search_zh":"电气与电子设备 PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-2:2019-04/A1:2021-08 PN-EN IEC 61000-3-2:2019-04/A2:2024-12","test_object_zh":"电气与电子设备"},{"_id":"6a5a56049af9f73f382546ca","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","test_object_en":"Electrical and electronic equipment","methodology":"Zmiany napięcia, wahania napięcia i migotania światła w publicznych sieciach zasilających niskiego napięcia","methodology_en":"Voltage changes, voltage fluctuations and flicker in public low-voltage supply systems","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmiany napięcia, wahania napięcia i migotania światła w publicznych sieciach zasilających niskiego napięcia","reference":"PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019-10 PN-EN 61000-3-3:2013-10/A2:2022-04","norm_bases":["PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019-10 PN-EN 61000-3-3:2013-10/A2:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne i elektroniczne Zmiany napięcia, wahania napięcia i migotania światła w publicznych sieciach zasilających niskiego napięcia PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019-10 PN-EN 61000-3-3:2013-10/A2:2022-04 Urzadzenia elektryczne i elektroniczne Zmiany napiecia, wahania napiecia i migotania swiatla w publicznych sieciach zasilajacych niskiego napiecia PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019-10 PN-EN 61000-3-3:2013-10/A2:2022-04","categories":["electronics"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical and electronic equipment Voltage changes, voltage fluctuations and flicker in public low-voltage supply systems PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019-10 PN-EN 61000-3-3:2013-10/A2:2022-04","search_zh":"电气与电子设备 公用低压供电网中的电压变化、电压波动与闪烁 PN-EN 61000-3-3:2013-10 PN-EN 61000-3-3:2013-10/A1:2019-10 PN-EN 61000-3-3:2013-10/A2:2022-04","test_object_zh":"电气与电子设备","methodology_zh":"公用低压供电网中的电压变化、电压波动与闪烁"},{"_id":"6a5a56049af9f73f382546cb","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia przemysłowe, naukowe i medyczne","test_object_en":"Industrial, scientific and medical equipment","methodology":"Napięcie zaburzeń radioelektrycznych ciągłych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz","methodology_en":"Continuous radio disturbance voltage on mains supply leads Range: 150 kHz – 30 MHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń radioelektrycznych ciągłych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz","reference":"PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12","norm_bases":["PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przemysłowe, naukowe i medyczne Napięcie zaburzeń radioelektrycznych ciągłych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 Urzadzenia przemyslowe, naukowe i medyczne Napiecie zaburzen radioelektrycznych ciaglych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Industrial, scientific and medical equipment Continuous radio disturbance voltage on mains supply leads Range: 150 kHz – 30 MHz PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12","search_zh":"工业、科学与医疗设备 供电网导线上的连续无线电骚扰电压 范围：150 kHz – 30 MHz PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12","test_object_zh":"工业、科学与医疗设备","methodology_zh":"供电网导线上的连续无线电骚扰电压 范围：150 kHz – 30 MHz"},{"_id":"6a5a56049af9f73f382546cc","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia przemysłowe, naukowe i medyczne","test_object_en":"Industrial, scientific and medical equipment","methodology":"Natężenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odległość pomiarowa 3 m","methodology_en":"Electromagnetic field strength Range: 30 MHz – 6 GHz measurement distance 3 m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odległość pomiarowa 3 m","reference":"PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08","norm_bases":["PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przemysłowe, naukowe i medyczne Natężenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odległość pomiarowa 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08 Urzadzenia przemyslowe, naukowe i medyczne Natezenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odleglosc pomiarowa 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Industrial, scientific and medical equipment Electromagnetic field strength Range: 30 MHz – 6 GHz measurement distance 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08","search_zh":"工业、科学与医疗设备 电磁场强度 范围：30 MHz – 6 GHz 测量距离 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55011:2016-05 PN-EN 55011:2016-05/A1:2017-06 PN-EN 55011:2016-05/A2:2021-08","test_object_zh":"工业、科学与医疗设备","methodology_zh":"电磁场强度 范围：30 MHz – 6 GHz 测量距离 3 m"},{"_id":"6a5a56049af9f73f382546cd","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia informatyczne","test_object_en":"Information technology equipment","methodology":"Napięcie zaburzeń radioelektrycznych ciągłych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz","methodology_en":"Continuous radio disturbance voltage on mains supply leads Range: 150 kHz – 30 MHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń radioelektrycznych ciągłych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz","reference":"PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12","norm_bases":["PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia informatyczne Napięcie zaburzeń radioelektrycznych ciągłych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 Urzadzenia informatyczne Napiecie zaburzen radioelektrycznych ciaglych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Information technology equipment Continuous radio disturbance voltage on mains supply leads Range: 150 kHz – 30 MHz PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12","search_zh":"信息技术设备 供电网导线上的连续无线电骚扰电压 范围：150 kHz – 30 MHz PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12","test_object_zh":"信息技术设备","methodology_zh":"供电网导线上的连续无线电骚扰电压 范围：150 kHz – 30 MHz"},{"_id":"6a5a56049af9f73f382546ce","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia informatyczne","test_object_en":"Information technology equipment","methodology":"Natężenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odległość pomiarowa 3 m","methodology_en":"Electromagnetic field strength Range: 30 MHz – 6 GHz measurement distance 3 m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odległość pomiarowa 3 m","reference":"PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03","norm_bases":["PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia informatyczne Natężenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odległość pomiarowa 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 Urzadzenia informatyczne Natezenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odleglosc pomiarowa 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Information technology equipment Electromagnetic field strength Range: 30 MHz – 6 GHz measurement distance 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03","search_zh":"信息技术设备 电磁场强度 范围：30 MHz – 6 GHz 测量距离 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03","test_object_zh":"信息技术设备","methodology_zh":"电磁场强度 范围：30 MHz – 6 GHz 测量距离 3 m"},{"_id":"6a5a56049af9f73f382546cf","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia multimedialne","test_object_en":"Multimedia equipment","methodology":"Napięcie zaburzeń radioelektrycznych ciągłych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz","methodology_en":"Continuous radio disturbance voltage on mains supply leads Range: 150 kHz – 30 MHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń radioelektrycznych ciągłych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz","reference":"PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05","norm_bases":["PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia multimedialne Napięcie zaburzeń radioelektrycznych ciągłych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Napiecie zaburzen radioelektrycznych ciaglych na przewodach sieci zasilania Zakres: 150 kHz – 30 MHz PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Multimedia equipment Continuous radio disturbance voltage on mains supply leads Range: 150 kHz – 30 MHz PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05","search_zh":"多媒体设备 供电网导线上的连续无线电骚扰电压 范围：150 kHz – 30 MHz PN-EN 55016-2-1:2014-09 PN-EN 55016-2-1:2014-09/A1:2017-12 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05","test_object_zh":"多媒体设备","methodology_zh":"供电网导线上的连续无线电骚扰电压 范围：150 kHz – 30 MHz"},{"_id":"6a5a56049af9f73f382546d0","lab_id":"69ad52a3de79e566650fb867","country":"PL","accr_number":"AB 1604","accr_body":"PCA","test_object":"Urządzenia multimedialne","test_object_en":"Multimedia equipment","methodology":"Natężenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odległość pomiarowa 3 m","methodology_en":"Electromagnetic field strength Range: 30 MHz – 6 GHz measurement distance 3 m","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odległość pomiarowa 3 m","reference":"PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05","norm_bases":["PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia multimedialne Natężenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odległość pomiarowa 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Natezenie pola elektromagnetycznego Zakres: 30 MHz – 6 GHz odleglosc pomiarowa 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Multimedia equipment Electromagnetic field strength Range: 30 MHz – 6 GHz measurement distance 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05","search_zh":"多媒体设备 电磁场强度 范围：30 MHz – 6 GHz 测量距离 3 m PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A1:2020-01 PN-EN 55016-2-3:2017-06/A2:2024-03 PN-EN 55032:2015-09 PN-EN 55032:2015-09/A1:2021-05","test_object_zh":"多媒体设备","methodology_zh":"电磁场强度 范围：30 MHz – 6 GHz 测量距离 3 m"}],"has_pdf":true}