🇵🇱 CENTRUM NAUKOWO-BADAWCZE PL

PCA AB 060 • Józefów k/Otwocka, Poland • 210 methods

Water & wastewater

CENTRUM NAUKOWO-BADAWCZE is a laboratory accredited by PCA under number AB 060 (Józefów k/Otwocka, Poland). Its accreditation scope covers 210 test methods in the following areas: Water & wastewater. Test objects include: Portable fire extinguishers, Portable aerosol dispenser, Mobile fire extinguisher, Components of Fixed Firefighting Systems supplying the extinguishin…. Most frequently used techniques: Templates method, Dry sieving method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 060
  • Methods in scope: 210
  • Types of test objects: 40
  • Techniques used: 9
  • City: Józefów k/Otwocka, Poland
Accreditation number
AB 060
Accreditation body
PCA
Address
OCHRONY PRZECIWPOŻAROWEJ im. Józefa Tuliszkowskiego, - PAŃSTWOWY INSTYTUT BADAWCZY, ZESPÓŁ LABORATORIÓW URZĄDZEŃ I ŚRODKÓW GAŚNICZYCH BU, ul. Nadwiślańska 213, 05-420 Józefów k/Otwocka
City
Józefów k/Otwocka, Poland

What this laboratory tests (40)

Analytical techniques used (9)

Accreditation scope — test methods (210)

No. Test object Methodology / Parameters Technique Reference document
Fire Extinguishing Equipment and Agents Laboratories Group BU
1 Sorbents Oil absorbing capacity PB/BU/901/1 edycja/edition 3 z/of 25.09.2020
2 Sorbents Chemical passivity PB/BU/901/1 edycja/edition 3 z/of 25.09.2020
3 Sorbents Buoyancy PB/BU/901/3 edycja/edition 2 z/of 25.09.2020
4 Sorbents Label dimensions PB/BU/901/2 edycja/edition 2 z/of 25.09.2020
5 Extinguishing powders Resistance to caking PN-EN 615:2009 (EN 615:2009)
6 Extinguishing powders Water repellency PN-EN 615:2009 (EN 615:2009)
7 Extinguishing powders Moisture content PN-EN 615:2009 (EN 615:2009)
8 Extinguishing powders Extinguishing efficiency – class A and B fire PN-EN 615:2009 (EN 615:2009) | PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
9 Portable fire extinguishers Total mass PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
10 Portable fire extinguishers Filling mass PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
11 Portable fire extinguishers Tightness: - gravimetric method - pressure loss method PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
12 Portable fire extinguishers control valve function: - gravimetric method - pressure loss method PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
13 Portable fire extinguishers Minimum operation time PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
14 Portable fire extinguishers - Dispersion of measurement results / Dispersion of measurement results PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
15 Portable fire extinguishers Operation time PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
16 Portable fire extinguishers Residue of extinguishing agent PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
17 Portable fire extinguishers Start of discharge PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
18 Portable fire extinguishers Minimum extinguishing efficiency – class A fire rating Minimum extinguishing efficiency – class B fire rating PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
19 Portable fire extinguishers Minimum extinguishing efficiency – class F fire rating PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
20 Portable fire extinguishers Effective temperature range of operation (-40 to +60) °C PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
21 Portable fire extinguishers Mechanisms/devices controlling operation and emission
Range (0 - 500) N Scope (0 - 500) N
PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
22 Portable fire extinguishers Safety devices PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
23 Portable fire extinguishers Force necessary to unlock safety device
Range (0-500) N Scope (0-500) N
PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
24 Portable fire extinguishers CO2 extinguisher horn resistance to static load PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
25 Portable fire extinguishers Security of CO2 extinguisher horn/hose fixing PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
26 Portable fire extinguishers CO2 extinguisher horn resistance to temperature PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
27 Portable fire extinguishers Pressure gauge scale PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
28 Portable fire extinguishers Control of discharge PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
29 Portable fire extinguishers working position PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
30 Portable fire extinguishers valve position PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
31 Portable fire extinguishers Length of hose with nozzle PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
32 Portable fire extinguishers dimensions of filling opening PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
33 Portable fire extinguishers dimensions of filter for water based extinguishers
Range - Wymiary liniowe do 20000 mm - Wymiary kątowe 0 - 90º - Średnica 0,3 - 10 mm Scope - linear dimensions to 20000 mm - angular dimensions 0 - 90º - diameter 0,3 - 10 mm
PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
34 Portable fire extinguishers Resistance to external corrosion / Resistance to external corrosion PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
35 Portable fire extinguishers Resistance to internal corrosion in water based extinguishers PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
36 Portable fire extinguishers Mounting bracket of portable extinguisher PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
37 Portable fire extinguishers Hose and coupling systems PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
38 Portable fire extinguishers Size of fields, letters and pictograms on the label / Size of fields, letters and pictograms on the label PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
39 Portable fire extinguishers Dielectric test of water based extinguishers / Dielectric test of water based extinguishers PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
40 Portable fire extinguishers Test of 1000 pressure indicator cycles PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
41 Portable fire extinguishers Colour Templates method PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
42 Portable fire extinguishers Measurement of geometric dimensions / Geometric dimensions
Range - Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm Scope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm
PB/BU/701/8 edycja / edition 1 z / of 21.04.2023
43 Mobile fire extinguisher Mass of extinguishing agent (filling mass) (range 20-300 kg) PN-EN 1866-1:2010 (EN 1866-1:2007)
44 Mobile fire extinguisher Tightness: - gravimetric method - pressure loss method PN-EN 1866-1:2010 (EN 1866-1:2007)
45 Mobile fire extinguisher Length of hose and coupling PN-EN 1866-1:2010 (EN 1866-1:2007)
46 Mobile fire extinguisher dimension of filter for water based extinguishers PN-EN 1866-1:2010 (EN 1866-1:2007)
47 Mobile fire extinguisher water jet range
Range - Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm Scope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm
PN-EN 1866-1:2010 (EN 1866-1:2007)
48 Mobile fire extinguisher Working position PN-EN 1866-1:2010 (EN 1866-1:2007)
49 Mobile fire extinguisher Start of discharge time PN-EN 1866-1:2010 (EN 1866-1:2007)
50 Mobile fire extinguisher Operation time PN-EN 1866-1:2010 (EN 1866-1:2007)
51 Mobile fire extinguisher Maximum residue of extinguishing agent PN-EN 1866-1:2010 (EN 1866-1:2007)
52 Mobile fire extinguisher Operation and extinguishing agent emission control devices
Range (0 - 500) N Scope (0 – 500) N
PN-EN 1866-1:2010 (EN 1866-1:2007)
53 Mobile fire extinguisher force necessary to unlock safety device
Range (0-500) N Scope (0-500) N
PN-EN 1866-1:2010 (EN 1866-1:2007)
54 Mobile fire extinguisher Colour Templates method PN-EN 1866-1:2010 (EN 1866-1:2007)
55 Mobile fire extinguisher Measurement of geometric dimensions / Geometric dimensions
Range - Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm Scope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm
PB/BU/702/2 edycja / edition 1 z / of 21.04.2023
56 Mobile fire extinguisher Energy required to trigger (2J) PN-EN 1866-1:2010 (EN 1866-1:2007)
57 Mobile fire extinguisher Effective temperature range of operation (-40 to +60) °C PN-EN 1866-1:2010 (EN 1866-1:2007)
58 Mobile fire extinguisher External corrosion test / External corrosion test PN-EN 1866-1:2010 (EN 1866-1:2007)
59 Mobile fire extinguisher Internal corrosion test of water based fire extinguishers / Internal corrosion test – water based fire extinguishers PN-EN 1866-1:2010 (EN 1866-1:2007)
60 Mobile fire extinguisher Size of fields, letters and pictograms on the label / Size of fields, letters and pictograms on the label PN-EN 1866-1:2010 (EN 1866-1:2007)
61 Mobile fire extinguisher Minimum extinguishing efficiency – class A fire rating PN-EN 1866-1:2010 (EN 1866-1:2007)
62 Mobile fire extinguisher Minimum extinguishing efficiency – class B fire rating PN-EN 1866-1:2010 (EN 1866-1:2007)
63 Mobile fire extinguisher Dielectric test / Dielectric test for water based fire extinguishers PN-EN 1866-1:2010 (EN 1866-1:2007)
64 Mobile fire extinguisher Test of 1000 pressure indicator cycles PN-EN 1866-1:2010 (EN 1866-1:2007)
65 Portable aerosol dispenser Extinguishing efficiency / Extinguishing efficiency PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
66 Portable aerosol dispenser Safety device: -work position -subassemblies PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
67 Portable aerosol dispenser Force necessary to unlock safety device
Range (5-50) N Scope (5-50) N
PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
68 Portable aerosol dispenser Force necessary to actuation
Range (0-50) N Scope (0-50) N
PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
69 Portable aerosol dispenser Resistance to external corrosion PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
70 Portable aerosol dispenser Resistance to internal corrosion PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
71 Portable aerosol dispenser Chemical and pressure stability PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
72 Portable aerosol dispenser Impact resistance PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
73 Portable aerosol dispenser Resistance to shock and mechanical damage PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
74 Portable aerosol dispenser Test pressure PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
75 Portable aerosol dispenser Burst pressure PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
76 Portable aerosol dispenser Media tolerance PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
77 Portable aerosol dispenser Filling pressure PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
78 Portable aerosol dispenser Maximum developed pressure PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
79 Portable aerosol dispenser Delay on operation PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
80 Portable aerosol dispenser Duration of discharge PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
81 Portable aerosol dispenser Minimum discharge of contents PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
82 Portable aerosol dispenser Retention of charge following partial discharge PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
83 Portable aerosol dispenser Effective throw range of the extinguishing agent PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
84 Portable aerosol dispenser Colour, hue / Colour PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
85 Portable aerosol dispenser Marking – primary information PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
86 Portable aerosol dispenser Marking - secondary information PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
87 Portable aerosol dispenser Minimum extinguishing efficiency – class B fire rating BS 6165:2019 zał. H5
88 Portable aerosol dispenser Minimum extinguishing efficiency – class F fire rating BS 6165:2019 zał. H6
89 Portable aerosol dispenser Minimum extinguishing efficiency – class A fire rating BS 6165:2019 zał. H4
90 Fire blankets Dimensions of the blanket PN-EN 1869:2019 (EN 1869:2019)
91 Fire blankets The mass of the blanket PN-EN 1869:2019 (EN 1869:2019)
92 Fire blankets Rolling of the blanket PN-EN 1869:2019 (EN 1869:2019)
93 Fire blankets Unfolding of the fire blanket PN-EN 1869:2019 (EN 1869:2019)
94 Fire blankets Electrical resistance of the blanket material PN-EN 1869:2019 (EN 1869:2019)
95 Fire blankets Fire performance for cooking oil and heptane PN-EN 1869:2019 (EN 1869:2019)
96 Fire blankets Edges of the blanket PN-EN 1869:2019 (EN 1869:2019)
97 Fire blankets Size of fields, letters and pictograms on the label PN-EN 1869:2019 (EN 1869:2019)
98 Fire blankets Blanket handles PN-EN 1869:2019 (EN 1869:2019)
99 Products containing metal components Resistance to neutral salt spray (NSS method) PN-EN ISO 9227:2023 (EN ISO 9227:2022)
100 Extinguishing devices Test fire performance – class A and B fire rating PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
101 Standpipes Dimensions
Range (5,95 - 3000) mm Scope (5,95 - 3000) mm
PN-73/M-51154, p. 5.4.2 | PN-M-51154:2015-04 p.5.3
102 Standpipes Mass
Range (0,02 - 24) kg Scope (0,02 - 24) kg
PN-73/M-51154, p. 5.4.3 | PN-M-51154:2015-04 p.5.4
103 Standpipes Stand tightness
Range do 10 MPa Scope to 10 MPa
PN-73/M-51154, p. 5.4.5 | PN-M-51154:2015-04 p.5.5
104 Standpipes Operation - functional testing PN-73/M-51154, p. 5.4.6 | PN-M-51154:2015-04 p.5.2
105 Standpipes Adhesion - torque
Range do 500 Nm Scope to 500 Nm
PN-73/M-51154, p. 5.4.7 | PN-M-51154:2015-04 p.5.6
106 Underground and pillar hydrants Dimensions
Range (0,001 - 5) m Scope (0,001 - 5) m
PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.2 | PN-EN 14384:2009, p. 5.2 (EN 14339:2005, p. 5.2)
107 Underground and pillar hydrants Mass
Range (0,4 - 150) kg Scope (0,4 - 150) kg
PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016
108 Underground and pillar hydrants Tightness - Resistance to internal pressure - Resistance to pressure difference PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 1074-1:2002, Załącznik A (EN 1074-1:2000, Annex A) | PN-EN 1074-1:2002, Załącznik B (EN 1074-1:2000, Annex B)
109 Underground and pillar hydrants Operation - Duration of the trial - Drainage time - Residual water in a hydrant
Range Czas: do 9 h 59 min 59,99 s. Objętość: do 1000 ml Scope Time: to 9 h 59 min 59,99 s Volume: to 1000 ml
PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.3 (EN 14339:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.6 (EN 1074-6:2008, p. 5.6)
110 Underground and pillar hydrants Kv factor
Range Natężenie przepływu wody: (137 - 4000) l/min Różnica ciśnień: do 130 kPa Scope Water flow rate: (137- 4000) l/min Differential pressure: to 130 kPa
PN-EN 14384:2009, p. 5.3 (EN 14384:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.3 (EN 1074-6:2008, p. 5.3)
111 Underground and pillar hydrants Workload resistance PN-EN 1074-6:2009, Załącznik C (EN 1074-6:2008, Annex C) | PN-EN 1074-2:2002, Załącznik A (EN 1074-2:2000, Annex A)
112 Underground and pillar hydrants Durability PN-EN 1074-6:2009, p. 5.5.1 (EN 1074-6:2008, p. 5.5.1)
113 Underground and pillar hydrants Resistance to disinfectants PN-EN 1074-1:2002 zał. E (EN 1074-1:2000 Annex E)
114 Pillar hydrants Bending resistance
Range do 50 kN Scope to 50 kN
PN-EN 1074-6:2009, p. 5.1.3 (EN 1074-6:2008, p. 5.1.3)
115 Internal hydrants Resistance to external corrosion / Resistance to external corrosion PN-EN 671-1:2012, załącznik B | PN-EN 671-2:2012, załącznik B (EN 671-1-2:2012, Annex B)
116 Internal hydrants Resistance to corrosion of waterways PN-EN 671-1:2012, załącznik D | PN-EN 671-2:2012, załącznik D (PN-EN 671-1-2:2012, Annex D)
117 Internal hydrants Force: - to rotate the reel - to pull out the hose
Range (20 - 500) N Scope (20 – 500) N
PN-EN 671-1:2012, załącznik F.4 (EN 671-1:2012, Annex F.4)
118 Internal hydrants Resistance of a hydrant to burt pressure PN-EN 671-1:2012, załącznik F.8 (EN 671-1:2012, Annex F.8)
119 Internal hydrants Torque of the nozzle
Range 0,3 - 25 Nm Scope 0,3 - 25 Nm
PN-EN 671-1:2012, załącznik E.2 | PN-EN 671-2:2012, załącznik E.2 (EN 671-1-2:2012, Annex E.2)
120 Internal hydrants Durability – bench test PN-EN 671-1:2012, załącznik F.2 (EN 671-1:2012, Annex F.2)
121 Internal hydrants Impact resistance of the nozzle PN-EN 671-1:2012, załącznik E.1 | PN-EN 671-2:2012, załącznik E.1 (EN 671-1-2:2012, Annex E.1)
122 Internal hydrants Throw range of the water jet
Range (0,5 – 30) m Scope (0,5 – 30) m
PN-EN 671-1:2012, załącznik E.4.2 | PN-EN 671-2:2012, załącznik E.4.2 (EN 671-1-2:2012, Annex E.4.2)
123 Internal hydrants Coverage area of the diffuse current PN-EN 671-1:2012, załącznik E.3 | PN-EN 671-2:2012, załącznik E.3 (EN 671-1-2:2012, Annex E.3)
124 Internal hydrants Water flow rate of the jet and spray stream / Water flow rate of dense and diffuse current
Range (10 - 500) l/min Scope (10 – 500) l/min
PN-EN 671-1:2012, załącznik E.4.1 | PN-EN 671-2:2012, załącznik E.4.1 (EN 671-1-2:2012, Annex E.4.1)
125 Internal hydrants Resistance of internal pressure PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)
126 Internal hydrants Resistance of plastic materials to light and scattered water jets PN-EN 671-1:2012, załącznik C | PN-EN 671-2:2012, załącznik C (EN 671-1-2:2012, Annex C)
127 Internal hydrants Impact and load resistance of hose reels and fittings PN-EN 671-1:2012, załącznik F.6 (EN 671-1:2012, Annex F.6)
128 Internal hydrants Dimensions - external diameter of the hose - diameter of the reel disc - diameter of the reel - width of the drum gap - hose length
Range (6 - 30000) mm Scope (6 – 30000) mm
PN-EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3 (EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3) | PN-EN 671-2:2012, p. 5.2.1, 5.4.1, 5.4.3 (EN 671-2:2012, p. 5.2.1, p. 5.4.1, p. 5.4.3)
129 Hydrant valves Corrosion resistance of water channels PN-EN 671-1:2012, załącznik D | PN-EN 671-2:2012, załącznik D (EN 671-1-2:2012, Annex D)
130 Hydrant valves Tightness of the closing PN-EN 671-2:2012, p. 4.3.5 (EN 671-2:2012, p. 4.3.5)
131 Hydrant valves Resistance to internal pressure PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)
132 Sprinklers Water scattering
Range (1 - 50) mm/min Scope (1 – 50) mm/min
PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)
133 Sprayers Water stream geometry
Range (1 - 250) mm Scope (1 – 250) mm
PB/BU/1601/1 edycja/edition 1 z/of 09.06.2016
134 Pumps Tightness (Pump leakage test) also in place indicated by contractor PN-EN 12259-12:2024
135 Pumps Pump casing strength also in place indicated by contractor PN-EN 12259-12:2024
136 Pumps Rotational speed
Range 100 – 30 000 obrotów na minutę Scope 100 – 30 000 rpm
PN-EN 12259-12:2024
137 Sprayers Water spray for upright or pendant sprinklers PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)
138 High expansion foam generators Foam parameters Foam efficiency (from calculation) PN-EN 13565-1:2019-09, zał. G (EN 13565-1:2019, Annex G)
139 Foam poureres, foam chambers Maximum flow and back pressure Check of foam discharge PN-EN 13565-1:2019 zał. J (EN 13565-1:2019 Annex J)
140 Foam sprayers Area coverage PN-EN 13565-1:2019 zał. I (EN 13565-1:2019 Annex I)
141 Water-mist nozzle Stress corrosion cracking of stainless steel nozzle parts (magnesium chloride test) IMO Msc/Circ. 1165 z dn. 10.06.2005 ze zmianami: IMO Msc.1/Circ.1269 z 03.06.2008 | IMO Msc.1/Circ. 1386 z 10.12.2010
142 Water-mist nozzle Coating resistance to temperatures Evaporation test IMO Msc/Circ 1165 z dn. 10.06.2005 r. Ze zmianami IMO MSC/Circ.1269 oraz IMO MSC.1/Circ. 1386
143 Water-mist nozzle Water distribution PN-EN 17450-2:2025 zał. B (EN 17450-2:2025 Annex B)
144 Water-mist nozzle Lateral discharge IMO Msc/Circ 1165 z dn. 10.06.2005 r. Wraz z rezolucją IMO A.800 (19) z dn. 23.11.1995 r.
145 Flexible sprinkler hose with end fittings Resistance to pressure cycling test EAD 100012-00-1106 (April 2020)
146 Flexible sprinkler hose with end fittings Fatigue EAD 100012-00-1106 (April 2020)
147 Flexible sprinkler hose with end fittings Resistance to vibration EAD 100012-00-1106 (April 2020)
148 Flexible sprinkler hose with end fittings Resistance to vaccum test EAD 100012-00-1106 (April 2020)
149 Flexible sprinkler hose with end fittings Friction loss EAD 100012-00-1106 (April 2020)
150 Flexible sprinkler hose with end fittings Hydrostatic strength EAD 100012-00-1106 (April 2020)
151 Flexible sprinkler hose with end fittings Seal inegrity EAD 100012-00-1106 (April 2020)
152 Flexible sprinkler hose with end fittings High pressure flow EAD 100012-00-1106 (April 2020)
153 Flexible sprinkler hose with end fittings Elongation EAD 100012-00-1106 (April 2020)
154 SorbentsE Grain composition Dry sieving method
Range sita 40 μm, 63 μm, 125 μm, 4 mm Scope sieves 40 μm, 63 μm, 125 μm, 4 mm
Regulated area: Flexible scope of accreditation
Dry sieving method Normy (Standards)
155 SorbentsE Bulk density
Regulated area: Flexible scope of accreditation
Normy (Standards)
156 Extinguishing powdersE Bulk density
Regulated area: Flexible scope of accreditation
Normy (Standards)
157 Extinguishing powdersE Grain composition on sieves 40 μm, 63 μm, 125 μm
Regulated area: Flexible scope of accreditation
Normy (Standards)
158 Paints and varnishes, Foam concentrates E Density by pycnometry method Weight method (pycnometer)
Range (0,7 – 1,6) g/cm3 Scope (0,7 – 1,6) g/cm3
Regulated area: Flexible scope of accreditation
Gravimetric method (pycnometer) Normy (Standards)
159 Foam concentrates E Density by aerometric method
Range (0,900-1,300) g/cm3 Scope (0,900-1,300) g/cm3
Regulated area: Flexible scope of accreditation
Normy (Standards)
160 Foam concentrates E Viscosity Hoeppler method
Range (0,6-4 800) mPa·s Scope (0,6-4 800) mPa·s
Regulated area: Flexible scope of accreditation
Hoeppler method Normy (Standards)
161 Foam concentrates E Viscosity of pseudoplastic liquids Rotational method with coaxial cylinders
Range (4 – 4 000) mPa*s Scope (4 – 4 000) mPa*s
Regulated area: Flexible scope of accreditation
Rotational method with coaxial cylinders Normy (Standards)
162 Foam concentrates E pH Potentiometric method
Range 1 - 14 Scope 1 – 14
Regulated area: Flexible scope of accreditation
Potentiometric method PN-EN 1262 (EN 1262) | IMO MSC.1/Circ.1312
163 Foam concentrates E Surface tension / Determination of surface tension Ring and plate method
Range (0 - 999,9) mN/m Scope (0 – 999,9) mN/m
Regulated area: Flexible scope of accreditation
Ring and plate method PN-EN 14370 (EN 14370)
164 Foam concentrates E Dissipation coefficient
Regulated area: Flexible scope of accreditation
IMO MSC.1/Circ.1312
165 Foam concentrates E Sediment content Gravimetric method
Regulated area: Flexible scope of accreditation
Gravimetric method PB/BU/802/1
166 Foam concentrates E Sediment content Volumetric method
Regulated area: Flexible scope of accreditation
Volumetric method PN-EN 1568-1 zał. C | PN-EN 1568-2 zał. C | PN-EN 1568-3 zał. C | PN-EN 1568-4 zał. C (EN 1568-1-4, Annex C) | IMO MSC.1/Circ.1312
167 Foam concentrates E Expansion ratio
Regulated area: Flexible scope of accreditation
PN-78/C-83603/07 | PN-EN1568-1 zał. G | PN-EN 1568-2 zał. G | PN-EN 1568-3 zał. G | PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312
168 Foam concentrates E Extinction time
Regulated area: Flexible scope of accreditation
PB/BU/802/1
169 Foam concentrates E Burn-back time
Regulated area: Flexible scope of accreditation
PB/BU/802/1
170 Foam concentrates E Foam drainage time
Regulated area: Flexible scope of accreditation
PN-78/C-83603/05 | PN-EN1568-1 zał. G | PN-EN 1568-2 zał. G | PN-EN 1568-3 zał. G | PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312
171 Foam concentrates E Extinguishing efficiency / Extinguishing efficiency
Regulated area: Flexible scope of accreditation
PN-EN1568-1 zał. H | PN-EN 1568-2 zał. H | PN-EN 1568-3 zał. H | PN-EN 1568-4 zał. H (EN 1568-1-4, Annex H) | IMO MSC.1/Circ.1312 | ICAO Doc 9137- AN/898 Podręcznik służb portu lotniczego pkt. 8.1.8
172 Foam concentrates E Extinguishing efficiency – class A fire rating
Regulated area: Flexible scope of accreditation
PB/BU/802/1
173 Foam concentrates E Extinguishing efficiency – small scale fire tests
Regulated area: Flexible scope of accreditation
PN-EN 1568-3 zał. I | PN-EN 1568-4 zał. I (EN 1568-3-4, Annex I) | IMO MSC.1/Circ.1312
174 Foam concentrates E Freezing point
Range (-30 - +5)°C Scope (-30 - +5)°C
Regulated area: Flexible scope of accreditation
PN-EN1568-1 zał. J (EN 1568-1, Annex J) | PN-EN 1568-2, zał. I | PN-EN 1568-3 zał. K | PN-EN 1568-4 zał. K (EN 1568-2-4, Annex K)
175 Foam concentrates E Stability/ separation test of foam concentrate
Regulated area: Flexible scope of accreditation
PN-EN 1568-1 zał. K (EN 1568-1 Annex K) | PN-EN 1568-2 zał. J (PN-EN 1568-2 Annex J) | PN-EN 1568-3 zał. M (EN 1568-3 Annex M) | PN-EN 1568-4 zał. L (EN 1568-4 Annex L) | IMO MSC.1/Circ.1312
176 Foam concentrates E Evaluation of film formation
Regulated area: Flexible scope of accreditation
PN-EN 1568-3 zał. L (EN 1568-3 Annex L)
177 Foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportionersE Mechanical strength Hydrostatic pressure test
Regulated area: Flexible scope of accreditation
Normy (Standards) | Procedury własne (Own procedures)
178 Foam generators, branchpipes and foam generators, foam sprayers, foam proportionersE Flow rate Discharge coefficient K (calculated) / Flow rate Discharge coefficient (from calculation)
Regulated area: Flexible scope of accreditation
Normy (Standards) | Procedury własne (Own procedures)
179 Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportioners)E Tightness
Regulated area: Flexible scope of accreditation
Normy (Standards) | Procedury własne (Own procedures)
180 Components of water and foam fixed extinguishing systems (i. e. foam generators, foam chambers, foam pourers, foam makers)E Heat and fire resistance
Regulated area: Flexible scope of accreditation
Normy Standards
181 Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. Sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportioners)E Stress corrosion in ammonia solution
Regulated area: Flexible scope of accreditation
Normy (Standards)
182 Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Corrosion in sulphur dioxide solution
Regulated area: Flexible scope of accreditation
Normy (Standards)
183 Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Resistance to vibration
Regulated area: Flexible scope of accreditation
Normy (Standards)
184 Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles) E Operation of humid air
Regulated area: Flexible scope of accreditation
Normy (Standards)
185 Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor) E Corrosion in salt spray
Regulated area: Flexible scope of accreditation
Normy (Standards)
186 Foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportionersE Internal corrosion
Regulated area: Flexible scope of accreditation
Normy (Standards)
187 Branchpipes and foam generators, water-foam monitor, foam sprayersE Foam parameters
Regulated area: Flexible scope of accreditation
Normy (Standards)
188 Water-foam monitorE Flow rate Discharge coefficient K (calculated)/ Flow rate Discharge coefficient (from calculation)
Range (17 – 9850) dm3/min Scope (17 – 9850) dm3/min
Regulated area: Flexible scope of accreditation
PN-EN 13565-1 załącznik E (EN 13565-1, Annex E)
189 Water-foam monitorE Throw range
Range do 100 m Scope to 100 m
Regulated area: Flexible scope of accreditation
PN-EN 13565-1 załącznik H (EN 13565-1, Annex H)
190 Foam proportionersE Accuracy of proportioning
Regulated area: Flexible scope of accreditation
PN-EN 13565-1 (EN 13565-1)
191 Foam chambersE Vapour seal
Range (0,05 - 2) bar Scope (0,05 - 2) bar
Regulated area: Flexible scope of accreditation
PN-EN 13565-1 (EN 13565-1)
192 Sprayers, foam sprayers, sprinklers E Heat resistance
Range (20 - 1000) º C Scope (20 - 1000) º C
Regulated area: Flexible scope of accreditation
Normy (Standards)
193 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Nominal opening temperaturę
Range (20 - 250) ºC Scope (20 – 250) ºC
Regulated area: Flexible scope of accreditation
Normy (Standards)
194 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Tensile endurance of sprinkler body
Range (0,1 - 6) kN Scope (0,1 – 6) kN
Regulated area: Flexible scope of accreditation
Normy (Standards)
195 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Correct operation at pressures from 0,1 bar to 100 bar
Range Temperatura: (380 - 420) ºC Czas: do 9 h 59 min 59,99 s Ciśnienie: do 100 bar Scope Temperature: (380 – 420) ºC Time: to 9 h 59 min 59,99 s Pressure: to 100 bar
Regulated area: Flexible scope of accreditation
Normy (Standards)
196 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Resistance to thermal shock
Range (5 - 200) ºC Scope (5 – 200) ºC
Regulated area: Flexible scope of accreditation
Normy (Standards)
197 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Outflow constant K from 0,5 to 400 (l/min)/(bar)1/2
Regulated area: Flexible scope of accreditation
Normy (Standards)
198 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Dimensions
Range (0,1 - 1000) mm Scope (0,1 – 1000) mm
Regulated area: Flexible scope of accreditation
Normy (Standards)
199 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Endurance of the sprinkler and sprinkler fixing parts
Regulated area: Flexible scope of accreditation
Normy (Standards)
200 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Endurance of the release element
Regulated area: Flexible scope of accreditation
Normy (Standards)
201 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Resistance to low temperature
Regulated area: Flexible scope of accreditation
Normy (Standards)
202 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Impact test
Regulated area: Flexible scope of accreditation
Normy (Standards)
203 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Heat exposure of uncoated and coated sprinklers
Regulated area: Flexible scope of accreditation
Normy (Standards)
204 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Water distribution above amd below the deflector
Regulated area: Flexible scope of accreditation
Normy (Standards)
205 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E C and RTI coefficient
Regulated area: Flexible scope of accreditation
Normy (Standards)
206 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Resistance to heat
Range (20-250)°C Scope (20 – 250) ºC
Regulated area: Flexible scope of accreditation
Normy (Standards)
207 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Water hammer test
Range (1-60) bar Scope (1 -60) bar
Regulated area: Flexible scope of accreditation
Normy (Standards)
208 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Resistance to low temperatures
Regulated area: Flexible scope of accreditation
Normy (Standards)
209 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E 30-day leakage test
Regulated area: Flexible scope of accreditation
Normy (Standards)
210 Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Vacuum test
Regulated area: Flexible scope of accreditation
Normy (Standards)

Reference standards (112)

BS 6165:2019 zał. H4
BS 6165:2019 zał. H5
BS 6165:2019 zał. H6
EAD 100012-00-1106 (April 2020)
ICAO Doc 9137- AN/898 Podręcznik służb portu lotniczego pkt. 8.1.8
IMO MSC.1/Circ.1312
IMO Msc.1/Circ. 1386 z 10.12.2010
IMO Msc/Circ 1165 z dn. 10.06.2005 r. Wraz z rezolucją IMO A.800 (19) z dn. 23.11.1995 r.
IMO Msc/Circ 1165 z dn. 10.06.2005 r. Ze zmianami IMO MSC/Circ.1269 oraz IMO MSC.1/Circ. 1386
IMO Msc/Circ. 1165 z dn. 10.06.2005 ze zmianami: IMO Msc.1/Circ.1269 z 03.06.2008
Normy (Standards)
Normy Standards
PB/BU/1601/1 edycja/edition 1 z/of 09.06.2016
PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016
PB/BU/701/8 edycja / edition 1 z / of 21.04.2023
PB/BU/702/2 edycja / edition 1 z / of 21.04.2023
PB/BU/802/1
PB/BU/901/1 edycja/edition 3 z/of 25.09.2020
PB/BU/901/2 edycja/edition 2 z/of 25.09.2020
PB/BU/901/3 edycja/edition 2 z/of 25.09.2020
PN-73/M-51154, p. 5.4.2
PN-73/M-51154, p. 5.4.3
PN-73/M-51154, p. 5.4.5
PN-73/M-51154, p. 5.4.6
PN-73/M-51154, p. 5.4.7
PN-78/C-83603/05
PN-78/C-83603/07
PN-EN 1074-1:2002 zał. E (EN 1074-1:2000 Annex E)
PN-EN 1074-1:2002, Załącznik A (EN 1074-1:2000, Annex A)
PN-EN 1074-1:2002, Załącznik B (EN 1074-1:2000, Annex B)
PN-EN 1074-2:2002, Załącznik A (EN 1074-2:2000, Annex A)
PN-EN 1074-6:2009, Załącznik C (EN 1074-6:2008, Annex C)
PN-EN 1074-6:2009, p. 5.1.3 (EN 1074-6:2008, p. 5.1.3)
PN-EN 1074-6:2009, p. 5.3 (EN 1074-6:2008, p. 5.3)
PN-EN 1074-6:2009, p. 5.5.1 (EN 1074-6:2008, p. 5.5.1)
PN-EN 1074-6:2009, p. 5.6 (EN 1074-6:2008, p. 5.6)
PN-EN 12259-12:2024
PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)
PN-EN 1262 (EN 1262)
PN-EN 13565-1 (EN 13565-1)
PN-EN 13565-1 załącznik E (EN 13565-1, Annex E)
PN-EN 13565-1 załącznik H (EN 13565-1, Annex H)
PN-EN 13565-1:2019 zał. I (EN 13565-1:2019 Annex I)
PN-EN 13565-1:2019 zał. J (EN 13565-1:2019 Annex J)
PN-EN 13565-1:2019-09, zał. G (EN 13565-1:2019, Annex G)
PN-EN 14339:2009, p. 5.2
PN-EN 14339:2009, p. 5.3 (EN 14339:2005, p. 5.3)
PN-EN 14370 (EN 14370)
PN-EN 14384:2009, p. 5.2 (EN 14339:2005, p. 5.2)
PN-EN 14384:2009, p. 5.3 (EN 14384:2005, p. 5.3)
PN-EN 1568-1 zał. C
PN-EN 1568-1 zał. K (EN 1568-1 Annex K)
PN-EN 1568-2 zał. C
PN-EN 1568-2 zał. G
PN-EN 1568-2 zał. H
PN-EN 1568-2 zał. J (PN-EN 1568-2 Annex J)
PN-EN 1568-2, zał. I
PN-EN 1568-3 zał. C
PN-EN 1568-3 zał. G
PN-EN 1568-3 zał. H
PN-EN 1568-3 zał. I
PN-EN 1568-3 zał. K
PN-EN 1568-3 zał. L (EN 1568-3 Annex L)
PN-EN 1568-3 zał. M (EN 1568-3 Annex M)
PN-EN 1568-4 zał. C (EN 1568-1-4, Annex C)
PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G)
PN-EN 1568-4 zał. H (EN 1568-1-4, Annex H)
PN-EN 1568-4 zał. I (EN 1568-3-4, Annex I)
PN-EN 1568-4 zał. K (EN 1568-2-4, Annex K)
PN-EN 1568-4 zał. L (EN 1568-4 Annex L)
PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8
PN-EN 17450-2:2025 zał. B (EN 17450-2:2025 Annex B)
PN-EN 1866-1:2010 (EN 1866-1:2007)
PN-EN 1869:2019 (EN 1869:2019)
PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)
PN-EN 615:2009 (EN 615:2009)
PN-EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3 (EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3)
PN-EN 671-1:2012, załącznik B
PN-EN 671-1:2012, załącznik C
PN-EN 671-1:2012, załącznik D
PN-EN 671-1:2012, załącznik E.1
PN-EN 671-1:2012, załącznik E.2
PN-EN 671-1:2012, załącznik E.3
PN-EN 671-1:2012, załącznik E.4.1
PN-EN 671-1:2012, załącznik E.4.2
PN-EN 671-1:2012, załącznik F.2 (EN 671-1:2012, Annex F.2)
PN-EN 671-1:2012, załącznik F.4 (EN 671-1:2012, Annex F.4)
PN-EN 671-1:2012, załącznik F.6 (EN 671-1:2012, Annex F.6)
PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7)
PN-EN 671-1:2012, załącznik F.8 (EN 671-1:2012, Annex F.8)
PN-EN 671-2:2012, p. 4.3.5 (EN 671-2:2012, p. 4.3.5)
PN-EN 671-2:2012, p. 5.2.1, 5.4.1, 5.4.3 (EN 671-2:2012, p. 5.2.1, p. 5.4.1, p. 5.4.3)
PN-EN 671-2:2012, załącznik B (EN 671-1-2:2012, Annex B)
PN-EN 671-2:2012, załącznik C (EN 671-1-2:2012, Annex C)
PN-EN 671-2:2012, załącznik D (EN 671-1-2:2012, Annex D)
PN-EN 671-2:2012, załącznik D (PN-EN 671-1-2:2012, Annex D)
PN-EN 671-2:2012, załącznik E.1 (EN 671-1-2:2012, Annex E.1)
PN-EN 671-2:2012, załącznik E.2 (EN 671-1-2:2012, Annex E.2)
PN-EN 671-2:2012, załącznik E.3 (EN 671-1-2:2012, Annex E.3)
PN-EN 671-2:2012, załącznik E.4.1 (EN 671-1-2:2012, Annex E.4.1)
PN-EN 671-2:2012, załącznik E.4.2 (EN 671-1-2:2012, Annex E.4.2)
PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)
PN-EN ISO 9227:2023 (EN ISO 9227:2022)
PN-EN1568-1 zał. G
PN-EN1568-1 zał. H
PN-EN1568-1 zał. J (EN 1568-1, Annex J)
PN-M-51154:2015-04 p.5.2
PN-M-51154:2015-04 p.5.3
PN-M-51154:2015-04 p.5.4
PN-M-51154:2015-04 p.5.5
PN-M-51154:2015-04 p.5.6
Procedury własne (Own procedures)