{"lab":{"_id":"69ad52a3de79e566650fb0f3","accr_number":"AB 060","country":"PL","accr_body":"PCA","address":"OCHRONY PRZECIWPOŻAROWEJ im. Józefa Tuliszkowskiego, - PAŃSTWOWY INSTYTUT BADAWCZY, ZESPÓŁ LABORATORIÓW URZĄDZEŃ I ŚRODKÓW GAŚNICZYCH BU, ul. Nadwiślańska 213, 05-420 Józefów k/Otwocka","categories":["water"],"city":"Józefów k/Otwocka","imported_at":"2026-03-08T10:42:43.265Z","methods_count":210,"name":"CENTRUM NAUKOWO-BADAWCZE","parse_status":"parsed","parse_version":3,"pdf_files":["AB_060.pdf"],"scope_summary":"","search_text":"centrum naukowo-badawcze ochrony przeciwpożarowej im. józefa tuliszkowskiego, - państwowy instytut badawczy, zespół laboratoriów urządzeń i środków gaśniczych bu, ul. nadwiślańska 213, 05-420 józefów k/otwocka food other water materials metrology electronics pharma environment automotive","status":"active","updated_at":"2026-03-08T14:50:07.664Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:55:45.168Z","parse_date":"2026-08-13T07:55:45.168Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.cnbop.pl/pl/kontakt","fields_of_testing":[{"codes":"C/4; C/17","pl":"Badania chemiczne wyrobów chemicznych, wyrobów innych","en":"Chemical tests of chemical products, other products"},{"codes":"H/5","pl":"Badania ogniowe wyrobów, materiałów, obiektów budowlanych","en":"Fire tests of products, materials, construction objects,"},{"codes":"J/5; J/17; J/21","pl":"Badania mechaniczne, badania metalograficzne wyrobów, materiałów, obiektów budowlanych, wyrobów innych, wyroby z tworzyw sztucznych i gumy","en":"Mechanical tests, metallographic tests of products, materials, construction objects, other products, plastic and rubber products"},{"codes":"M/5","pl":"Badania inne wyrobów, materiałów, obiektów budowlanych","en":"Other tests of products, materials and construction objects"},{"codes":"N/4; N/5; N/13; N/17; N/21; N/23","pl":"Badania właściwości fizycznych wyrobów chemicznych, wyrobów, materiałów, obiektów budowlanych, maszyn i urządzeń, wyrobów innych, wyrobów z tworzyw sztucznych i gumy, tekstyliów I skóry","en":"Tests of physical properties of chemical products, products, materials, construction objects, machinery and devices, other products, plastic and rubber products, textiles and leather"},{"codes":null,"pl":"Przedmiot badań/wyrób / Rodzaj działalności/badane cechy/metoda / Dokumenty odniesienia","en":"Material/product tested / Type of activity/parameter/characteristic tested / Reference documents"},{"codes":null,"pl":"Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","en":"The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity."}],"issue":{"no":"27","date":"23.07.2026"},"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/b0cc08d105aaf869a3ac9c68ed910a07/AB%20060.pdf","has_en":true,"category_counts":{"other":165,"water":35,"materials":4,"petro":2,"food":2,"environment":2,"metrology":1,"automotive":1},"category_scores":{"other":128.42,"water":5.78,"materials":0.08,"petro":0.02,"food":0.02,"environment":0.02,"metrology":0,"automotive":0},"has_zh":true},"methods":[{"_id":"6a7d78810636ba417e419c72","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Sorbenty / Sorbents","methodology":"Zdolność pochłaniania oleju / Oil absorbing capacity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zdolność pochłaniania oleju / Oil absorbing capacity","reference":"PB/BU/901/1 edycja/edition 3 z/of 25.09.2020","norm_bases":["PB/BU/901/1 edycja/edition 3 z/of 25.09.2020"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sorbenty / Sorbents Zdolność pochłaniania oleju / Oil absorbing capacity PB/BU/901/1 edycja/edition 3 z/of 25.09.2020 Sorbenty / Sorbents Zdolnosc pochlaniania oleju / Oil absorbing capacity PB/BU/901/1 edycja/edition 3 z/of 25.09.2020","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Oil absorbing capacity","search_en":"Sorbents Oil absorbing capacity Fire Extinguishing Equipment and Agents Laboratories Group BU PB/BU/901/1 edycja/edition 3 z/of 25.09.2020","test_object_en":"Sorbents","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"吸附剂 / Sorbents 灭火设备与灭火剂实验室组 BU PB/BU/901/1 edycja/edition 3 z/of 25.09.2020","test_object_zh":"吸附剂 / Sorbents"},{"_id":"6a7d78810636ba417e419c73","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Sorbenty / Sorbents","methodology":"Bierność chemiczna / Chemical passivity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Bierność chemiczna / Chemical passivity","reference":"PB/BU/901/1 edycja/edition 3 z/of 25.09.2020","norm_bases":["PB/BU/901/1 edycja/edition 3 z/of 25.09.2020"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sorbenty / Sorbents Bierność chemiczna / Chemical passivity PB/BU/901/1 edycja/edition 3 z/of 25.09.2020 Sorbenty / Sorbents Biernosc chemiczna / Chemical passivity PB/BU/901/1 edycja/edition 3 z/of 25.09.2020","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Chemical passivity","search_en":"Sorbents Chemical passivity Fire Extinguishing Equipment and Agents Laboratories Group BU PB/BU/901/1 edycja/edition 3 z/of 25.09.2020","test_object_en":"Sorbents","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"吸附剂 / Sorbents 灭火设备与灭火剂实验室组 BU PB/BU/901/1 edycja/edition 3 z/of 25.09.2020","test_object_zh":"吸附剂 / Sorbents"},{"_id":"6a7d78810636ba417e419c74","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Sorbenty / Sorbents","methodology":"Pływalność / Buoyancy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pływalność / Buoyancy","reference":"PB/BU/901/3 edycja/edition 2 z/of 25.09.2020","norm_bases":["PB/BU/901/3 edycja/edition 2 z/of 25.09.2020"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sorbenty / Sorbents Pływalność / Buoyancy PB/BU/901/3 edycja/edition 2 z/of 25.09.2020 Sorbenty / Sorbents Plywalnosc / Buoyancy PB/BU/901/3 edycja/edition 2 z/of 25.09.2020","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Buoyancy","search_en":"Sorbents Buoyancy Fire Extinguishing Equipment and Agents Laboratories Group BU PB/BU/901/3 edycja/edition 2 z/of 25.09.2020","test_object_en":"Sorbents","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"吸附剂 / Sorbents 灭火设备与灭火剂实验室组 BU PB/BU/901/3 edycja/edition 2 z/of 25.09.2020","test_object_zh":"吸附剂 / Sorbents"},{"_id":"6a7d78810636ba417e419c75","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Sorbenty / Sorbents","methodology":"Wymiary etykiety / Label dimensions","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary etykiety / Label dimensions","reference":"PB/BU/901/2 edycja/edition 2 z/of 25.09.2020","norm_bases":["PB/BU/901/2 edycja/edition 2 z/of 25.09.2020"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sorbenty / Sorbents Wymiary etykiety / Label dimensions PB/BU/901/2 edycja/edition 2 z/of 25.09.2020 Sorbenty / Sorbents Wymiary etykiety / Label dimensions PB/BU/901/2 edycja/edition 2 z/of 25.09.2020","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Label dimensions","search_en":"Sorbents Label dimensions Fire Extinguishing Equipment and Agents Laboratories Group BU PB/BU/901/2 edycja/edition 2 z/of 25.09.2020","test_object_en":"Sorbents","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"吸附剂 / Sorbents 灭火设备与灭火剂实验室组 BU PB/BU/901/2 edycja/edition 2 z/of 25.09.2020","test_object_zh":"吸附剂 / Sorbents"},{"_id":"6a7d78810636ba417e419c76","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Proszki gaśnicze / Extinguishing powders","methodology":"Odporność na zbrylanie / Resistance to caking","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zbrylanie / Resistance to caking","reference":"PN-EN 615:2009 (EN 615:2009)","norm_bases":["PN-EN 615:2009 (EN 615:2009)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Proszki gaśnicze / Extinguishing powders Odporność na zbrylanie / Resistance to caking PN-EN 615:2009 (EN 615:2009) Proszki gasnicze / Extinguishing powders Odpornosc na zbrylanie / Resistance to caking PN-EN 615:2009 (EN 615:2009)","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to caking","search_en":"Extinguishing powders Resistance to caking Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 615:2009 (EN 615:2009)","test_object_en":"Extinguishing powders","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火干粉 / Extinguishing powders 灭火设备与灭火剂实验室组 BU PN-EN 615:2009 (EN 615:2009)","test_object_zh":"灭火干粉 / Extinguishing powders"},{"_id":"6a7d78810636ba417e419c77","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Proszki gaśnicze / Extinguishing powders","methodology":"Odporność na zwilżanie wodą / Water repellency","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zwilżanie wodą / Water repellency","reference":"PN-EN 615:2009 (EN 615:2009)","norm_bases":["PN-EN 615:2009 (EN 615:2009)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Proszki gaśnicze / Extinguishing powders Odporność na zwilżanie wodą / Water repellency PN-EN 615:2009 (EN 615:2009) Proszki gasnicze / Extinguishing powders Odpornosc na zwilzanie woda / Water repellency PN-EN 615:2009 (EN 615:2009)","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Water repellency","search_en":"Extinguishing powders Water repellency Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 615:2009 (EN 615:2009)","test_object_en":"Extinguishing powders","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火干粉 / Extinguishing powders 灭火设备与灭火剂实验室组 BU PN-EN 615:2009 (EN 615:2009)","test_object_zh":"灭火干粉 / Extinguishing powders"},{"_id":"6a7d78810636ba417e419c78","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Proszki gaśnicze / Extinguishing powders","methodology":"Zawartość wilgoci / Moisture content","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci / Moisture content","reference":"PN-EN 615:2009 (EN 615:2009)","norm_bases":["PN-EN 615:2009 (EN 615:2009)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Proszki gaśnicze / Extinguishing powders Zawartość wilgoci / Moisture content PN-EN 615:2009 (EN 615:2009) Proszki gasnicze / Extinguishing powders Zawartosc wilgoci / Moisture content PN-EN 615:2009 (EN 615:2009)","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Moisture content","search_en":"Extinguishing powders Moisture content Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 615:2009 (EN 615:2009)","test_object_en":"Extinguishing powders","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火干粉 / Extinguishing powders 灭火设备与灭火剂实验室组 BU PN-EN 615:2009 (EN 615:2009)","test_object_zh":"灭火干粉 / Extinguishing powders"},{"_id":"6a7d78810636ba417e419c79","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Proszki gaśnicze / Extinguishing powders","methodology":"Skuteczność gaśnicza w zakresie pożarów grupy A i B / Extinguishing efficiency – class A and B fire","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność gaśnicza w zakresie pożarów grupy A i B / Extinguishing efficiency – class A and B fire","reference":"PN-EN 615:2009 (EN 615:2009) | PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 615:2009 (EN 615:2009)","PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Proszki gaśnicze / Extinguishing powders Skuteczność gaśnicza w zakresie pożarów grupy A i B / Extinguishing efficiency – class A and B fire PN-EN 615:2009 (EN 615:2009) | PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Proszki gasnicze / Extinguishing powders Skutecznosc gasnicza w zakresie pozarow grupy A i B / Extinguishing efficiency – class A and B fire PN-EN 615:2009 (EN 615:2009) | PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Extinguishing efficiency – class A and B fire","search_en":"Extinguishing powders Extinguishing efficiency – class A and B fire Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 615:2009 (EN 615:2009) | PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Extinguishing powders","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火干粉 / Extinguishing powders 灭火设备与灭火剂实验室组 BU PN-EN 615:2009 (EN 615:2009) | PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"灭火干粉 / Extinguishing powders"},{"_id":"6a7d78810636ba417e419c7a","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Masa całkowita / total mass","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Masa całkowita / total mass","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Masa całkowita / total mass PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Masa calkowita / total mass PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Total mass","search_en":"Portable fire extinguishers Total mass Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c7b","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Masa napełnienia / filling mass","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Masa napełnienia / filling mass","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Masa napełnienia / filling mass PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Masa napelnienia / filling mass PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Filling mass","search_en":"Portable fire extinguishers Filling mass Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c7c","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Szczelność / tightness: - metodą ubytku masy/ gravimetric method - metodą ubytku ciśnienia/ pressure loss method","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność / tightness: - metodą ubytku masy/ gravimetric method - metodą ubytku ciśnienia/ pressure loss method","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Szczelność / tightness: - metodą ubytku masy/ gravimetric method - metodą ubytku ciśnienia/ pressure loss method PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Szczelnosc / tightness: - metoda ubytku masy/ gravimetric method - metoda ubytku cisnienia/ pressure loss method PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Tightness: - gravimetric method - pressure loss method","search_en":"Portable fire extinguishers Tightness: - gravimetric method - pressure loss method Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c7d","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Działanie zaworu sterującego: / control valve function: - metodą ubytku masy / gravimetric method - metodą ubytku ciśnienia / pressure loss method","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Działanie zaworu sterującego: / control valve function: - metodą ubytku masy / gravimetric method - metodą ubytku ciśnienia / pressure loss method","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Działanie zaworu sterującego: / control valve function: - metodą ubytku masy / gravimetric method - metodą ubytku ciśnienia / pressure loss method PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Dzialanie zaworu sterujacego: / control valve function: - metoda ubytku masy / gravimetric method - metoda ubytku cisnienia / pressure loss method PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"control valve function: - gravimetric method - pressure loss method","search_en":"Portable fire extinguishers control valve function: - gravimetric method - pressure loss method Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c7e","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Minimalny czas działania / Minimum operation time","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Minimalny czas działania / Minimum operation time","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Minimalny czas działania / Minimum operation time PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Minimalny czas dzialania / Minimum operation time PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Minimum operation time","search_en":"Portable fire extinguishers Minimum operation time Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c7f","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"- Rozrzut wyników pomiarów / Dispersion of measurement results","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"- Rozrzut wyników pomiarów / Dispersion of measurement results","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers - Rozrzut wyników pomiarów / Dispersion of measurement results PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers - Rozrzut wynikow pomiarow / Dispersion of measurement results PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"- Dispersion of measurement results / Dispersion of measurement results","search_en":"Portable fire extinguishers - Dispersion of measurement results / Dispersion of measurement results Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c80","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Czas działania / Operation time","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas działania / Operation time","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Czas działania / Operation time PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Czas dzialania / Operation time PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Operation time","search_en":"Portable fire extinguishers Operation time Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c81","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Pozostałość środka gaśniczego / Residue of extinguishing agent","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pozostałość środka gaśniczego / Residue of extinguishing agent","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Pozostałość środka gaśniczego / Residue of extinguishing agent PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Pozostalosc srodka gasniczego / Residue of extinguishing agent PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Residue of extinguishing agent","search_en":"Portable fire extinguishers Residue of extinguishing agent Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c82","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Początek rozładowywania / Start of discharge","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Początek rozładowywania / Start of discharge","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Początek rozładowywania / Start of discharge PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Poczatek rozladowywania / Start of discharge PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Start of discharge","search_en":"Portable fire extinguishers Start of discharge Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c83","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A, Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class A fire rating Minimum extinguishing efficiency – class B fire rating","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A, Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class A fire rating Minimum extinguishing efficiency – class B fire rating","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A, Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class A fire rating Minimum extinguishing efficiency – class B fire rating PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Minimalna skutecznosc gasnicza – ocena pozaru testowego grupy A, Minimalna skutecznosc gasnicza – ocena pozaru testowego grupy B / Minimum extinguishing efficiency – class A fire rating Minimum extinguishing efficiency – class B fire rating PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Minimum extinguishing efficiency – class A fire rating Minimum extinguishing efficiency – class B fire rating","search_en":"Portable fire extinguishers Minimum extinguishing efficiency – class A fire rating Minimum extinguishing efficiency – class B fire rating Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c84","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy F / Minimum extinguishing efficiency – class F fire rating","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy F / Minimum extinguishing efficiency – class F fire rating","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy F / Minimum extinguishing efficiency – class F fire rating PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Minimalna skutecznosc gasnicza – ocena pozaru testowego grupy F / Minimum extinguishing efficiency – class F fire rating PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Minimum extinguishing efficiency – class F fire rating","search_en":"Portable fire extinguishers Minimum extinguishing efficiency – class F fire rating Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c85","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Efektywny zakres temperatur działania (-40 do +60) °C / Effective temperaturę range of operation (-40 to +60) °C","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Efektywny zakres temperatur działania (-40 do +60) °C / Effective temperaturę range of operation (-40 to +60) °C","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Efektywny zakres temperatur działania (-40 do +60) °C / Effective temperaturę range of operation (-40 to +60) °C PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Efektywny zakres temperatur dzialania (-40 do +60) °C / Effective temperature range of operation (-40 to +60) °C PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Effective temperature range of operation (-40 to +60) °C","search_en":"Portable fire extinguishers Effective temperature range of operation (-40 to +60) °C Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c86","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Mechanizmy/urządzenia sterujące działaniem i emisją / Mechanisms/devices controlling operation and emission","parameters":[{"name":"Zakres","range":"(0 - 500) N"},{"name":"Scope","range":"(0 - 500) N"}],"technique":null,"techniques":[],"computed":[],"activity":"Mechanizmy/urządzenia sterujące działaniem i emisją / Mechanisms/devices controlling operation and emission\nZakres:\nZakres (0 - 500) N\nScope (0 - 500) N","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Mechanizmy/urządzenia sterujące działaniem i emisją / Mechanisms/devices controlling operation and emission\nZakres:\nZakres (0 - 500) N\nScope (0 - 500) N PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Mechanizmy/urzadzenia sterujace dzialaniem i emisja / Mechanisms/devices controlling operation and emission\nZakres:\nZakres (0 - 500) N\nScope (0 - 500) N PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Mechanisms/devices controlling operation and emission","parameters_en":[{"name":"Range","range":"(0 - 500) N"},{"name":"Scope","range":"(0 - 500) N"}],"search_en":"Portable fire extinguishers Mechanisms/devices controlling operation and emission Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0 - 500) N"},{"name":"范围","range":"(0 - 500) N"}],"search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c87","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Urządzenia zabezpieczające / Safety devices","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Urządzenia zabezpieczające / Safety devices","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Urządzenia zabezpieczające / Safety devices PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Urzadzenia zabezpieczajace / Safety devices PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Safety devices","search_en":"Portable fire extinguishers Safety devices Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c88","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Siła wymagana do odbezpieczenia urządzenia zabezpieczającego / Force necessary to unlock safety device","parameters":[{"name":"Zakres","range":"(0-500) N"},{"name":"Scope","range":"(0-500) N"}],"technique":null,"techniques":[],"computed":[],"activity":"Siła wymagana do odbezpieczenia urządzenia zabezpieczającego / Force necessary to unlock safety device\nZakres:\nZakres (0-500) N\nScope (0-500) N","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Siła wymagana do odbezpieczenia urządzenia zabezpieczającego / Force necessary to unlock safety device\nZakres:\nZakres (0-500) N\nScope (0-500) N PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Sila wymagana do odbezpieczenia urzadzenia zabezpieczajacego / Force necessary to unlock safety device\nZakres:\nZakres (0-500) N\nScope (0-500) N PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Force necessary to unlock safety device","parameters_en":[{"name":"Range","range":"(0-500) N"},{"name":"Scope","range":"(0-500) N"}],"search_en":"Portable fire extinguishers Force necessary to unlock safety device Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0-500) N"},{"name":"范围","range":"(0-500) N"}],"search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c89","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Odporność prądownicy gaśnicy CO2 na obciążenia statyczne / Horn resistance to static load","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność prądownicy gaśnicy CO2 na obciążenia statyczne / Horn resistance to static load","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Odporność prądownicy gaśnicy CO2 na obciążenia statyczne / Horn resistance to static load PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Odpornosc pradownicy gasnicy CO2 na obciazenia statyczne / Horn resistance to static load PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"CO2 extinguisher horn resistance to static load","search_en":"Portable fire extinguishers CO2 extinguisher horn resistance to static load Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c8a","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Zabezpieczenie połączeń prądownicy gaśnicy CO2 / Security of horn/hose fixing","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zabezpieczenie połączeń prądownicy gaśnicy CO2 / Security of horn/hose fixing","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Zabezpieczenie połączeń prądownicy gaśnicy CO2 / Security of horn/hose fixing PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Zabezpieczenie polaczen pradownicy gasnicy CO2 / Security of horn/hose fixing PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Security of CO2 extinguisher horn/hose fixing","search_en":"Portable fire extinguishers Security of CO2 extinguisher horn/hose fixing Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c8b","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Odporność termiczna prądownicy gaśnicy CO2 / Horn resistance to temperature","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność termiczna prądownicy gaśnicy CO2 / Horn resistance to temperature","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Odporność termiczna prądownicy gaśnicy CO2 / Horn resistance to temperature PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Odpornosc termiczna pradownicy gasnicy CO2 / Horn resistance to temperature PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"CO2 extinguisher horn resistance to temperature","search_en":"Portable fire extinguishers CO2 extinguisher horn resistance to temperature Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c8c","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Skala ciśnieniomierza / Pressure gauge scale","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skala ciśnieniomierza / Pressure gauge scale","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Skala ciśnieniomierza / Pressure gauge scale PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Skala cisnieniomierza / Pressure gauge scale PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["metrology"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Pressure gauge scale","search_en":"Portable fire extinguishers Pressure gauge scale Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c8d","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Sterowanie rozładowywaniem / Control of discharge","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sterowanie rozładowywaniem / Control of discharge","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Sterowanie rozładowywaniem / Control of discharge PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Sterowanie rozladowywaniem / Control of discharge PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Control of discharge","search_en":"Portable fire extinguishers Control of discharge Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c8e","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Pozycja pracy / working position","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pozycja pracy / working position","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Pozycja pracy / working position PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Pozycja pracy / working position PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"working position","search_en":"Portable fire extinguishers working position Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c8f","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Położenie zaworu / valve position","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Położenie zaworu / valve position","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Położenie zaworu / valve position PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Polozenie zaworu / valve position PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"valve position","search_en":"Portable fire extinguishers valve position Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c90","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Długość węża z dyszą / hose with nozzle","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Długość węża z dyszą / hose with nozzle","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Długość węża z dyszą / hose with nozzle PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Dlugosc weza z dysza / hose with nozzle PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Length of hose with nozzle","search_en":"Portable fire extinguishers Length of hose with nozzle Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c91","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Wymiary otworu do napełniania / dimensions of filling opening","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary otworu do napełniania / dimensions of filling opening","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Wymiary otworu do napełniania / dimensions of filling opening PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Wymiary otworu do napelniania / dimensions of filling opening PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"dimensions of filling opening","search_en":"Portable fire extinguishers dimensions of filling opening Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c92","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Wymiary filtra dla gaśnic wodnych / dimensions of filter for water based extinguishers","parameters":[{"name":"Zakres","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0 - 90º - Średnica 0,3 - 10 mm"},{"name":"Scope","range":"- linear dimensions to 20000 mm - angular dimensions 0 - 90º - diameter 0,3 - 10 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary filtra dla gaśnic wodnych / dimensions of filter for water based extinguishers\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary kątowe 0 - 90º - Średnica 0,3 - 10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0 - 90º - diameter 0,3 - 10 mm","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Wymiary filtra dla gaśnic wodnych / dimensions of filter for water based extinguishers\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary kątowe 0 - 90º - Średnica 0,3 - 10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0 - 90º - diameter 0,3 - 10 mm PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Wymiary filtra dla gasnic wodnych / dimensions of filter for water based extinguishers\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary katowe 0 - 90º - Srednica 0,3 - 10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0 - 90º - diameter 0,3 - 10 mm PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"dimensions of filter for water based extinguishers","parameters_en":[{"name":"Range","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0 - 90º - Średnica 0,3 - 10 mm"},{"name":"Scope","range":"- linear dimensions to 20000 mm - angular dimensions 0 - 90º - diameter 0,3 - 10 mm"}],"search_en":"Portable fire extinguishers dimensions of filter for water based extinguishers Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0 - 90º - Średnica 0,3 - 10 mm"},{"name":"范围","range":"- linear dimensions to 20000 mm - angular dimensions 0 - 90º - diameter 0,3 - 10 mm"}],"search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c93","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Odporność na korozję zewnętrzną / Resistance to external corrosion","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na korozję zewnętrzną / Resistance to external corrosion","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Odporność na korozję zewnętrzną / Resistance to external corrosion PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Odpornosc na korozje zewnetrzna / Resistance to external corrosion PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to external corrosion / Resistance to external corrosion","search_en":"Portable fire extinguishers Resistance to external corrosion / Resistance to external corrosion Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c94","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Odporność na działanie środka gaśniczego w gaśnicach wodnych / Resistance to internal corrosion in water based extinguishers","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie środka gaśniczego w gaśnicach wodnych / Resistance to internal corrosion in water based extinguishers","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Odporność na działanie środka gaśniczego w gaśnicach wodnych / Resistance to internal corrosion in water based extinguishers PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Odpornosc na dzialanie srodka gasniczego w gasnicach wodnych / Resistance to internal corrosion in water based extinguishers PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to internal corrosion in water based extinguishers","search_en":"Portable fire extinguishers Resistance to internal corrosion in water based extinguishers Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c95","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Wspornik mocujący gaśnicy przenośnej (wieszak) / Mounting bracket of portable extinguisher","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wspornik mocujący gaśnicy przenośnej (wieszak) / Mounting bracket of portable extinguisher","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Wspornik mocujący gaśnicy przenośnej (wieszak) / Mounting bracket of portable extinguisher PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Wspornik mocujacy gasnicy przenosnej (wieszak) / Mounting bracket of portable extinguisher PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Mounting bracket of portable extinguisher","search_en":"Portable fire extinguishers Mounting bracket of portable extinguisher Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c96","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Zespoły węża i łącznika / Hose and coupling systems","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zespoły węża i łącznika / Hose and coupling systems","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Zespoły węża i łącznika / Hose and coupling systems PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Zespoly weza i lacznika / Hose and coupling systems PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Hose and coupling systems","search_en":"Portable fire extinguishers Hose and coupling systems Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c97","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Wielkość pól, liter i piktogramów na etykiecie / Size of fields, letters and pictograms on the label","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wielkość pól, liter i piktogramów na etykiecie / Size of fields, letters and pictograms on the label","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Wielkość pól, liter i piktogramów na etykiecie / Size of fields, letters and pictograms on the label PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Wielkosc pol, liter i piktogramow na etykiecie / Size of fields, letters and pictograms on the label PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Size of fields, letters and pictograms on the label / Size of fields, letters and pictograms on the label","search_en":"Portable fire extinguishers Size of fields, letters and pictograms on the label / Size of fields, letters and pictograms on the label Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c98","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Badanie dielektryczne gaśnic wodnych / Dielectric test of water based extinguishers","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie dielektryczne gaśnic wodnych / Dielectric test of water based extinguishers","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Badanie dielektryczne gaśnic wodnych / Dielectric test of water based extinguishers PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Badanie dielektryczne gasnic wodnych / Dielectric test of water based extinguishers PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Dielectric test of water based extinguishers / Dielectric test of water based extinguishers","search_en":"Portable fire extinguishers Dielectric test of water based extinguishers / Dielectric test of water based extinguishers Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c99","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Badanie 1000 cykli wskaźnika ciśnienia / Test of 1000 pressure indicator cycles","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie 1000 cykli wskaźnika ciśnienia / Test of 1000 pressure indicator cycles","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Badanie 1000 cykli wskaźnika ciśnienia / Test of 1000 pressure indicator cycles PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Badanie 1000 cykli wskaznika cisnienia / Test of 1000 pressure indicator cycles PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Test of 1000 pressure indicator cycles","search_en":"Portable fire extinguishers Test of 1000 pressure indicator cycles Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c9a","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Kolor (barwa) / colour","parameters":[],"technique":"Metoda wzorników","techniques":["Metoda wzorników"],"computed":[],"activity":"Kolor (barwa) / colour\nMetoda wzorników","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Kolor (barwa) / colour\nMetoda wzorników PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Gasnice przenosne / Portable fire extinguishers Kolor (barwa) / colour\nMetoda wzornikow PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Colour","search_en":"Portable fire extinguishers Colour Templates method Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","technique_en":"Templates method","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"手提式灭火器 样板法 灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_zh":"手提式灭火器","technique_zh":"样板法"},{"_id":"6a7d78810636ba417e419c9b","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Pomiar wymiarów geometrycznych / Geometric dimensions","parameters":[{"name":"Zakres","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm"},{"name":"Scope","range":"- linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar wymiarów geometrycznych / Geometric dimensions\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm","reference":"PB/BU/701/8 edycja / edition 1 z / of 21.04.2023","norm_bases":["PB/BU/701/8 edycja / edition 1 z / of 21.04.2023"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Pomiar wymiarów geometrycznych / Geometric dimensions\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm PB/BU/701/8 edycja / edition 1 z / of 21.04.2023 Gasnice przenosne / Portable fire extinguishers Pomiar wymiarow geometrycznych / Geometric dimensions\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary katowe 0-90º - Srednica 0,3-10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm PB/BU/701/8 edycja / edition 1 z / of 21.04.2023","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Measurement of geometric dimensions / Geometric dimensions","parameters_en":[{"name":"Range","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm"},{"name":"Scope","range":"- linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm"}],"search_en":"Portable fire extinguishers Measurement of geometric dimensions / Geometric dimensions Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PB/BU/701/8 edycja / edition 1 z / of 21.04.2023","test_object_en":"Portable fire extinguishers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm"},{"name":"范围","range":"- linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm"}],"search_zh":"手提式灭火器 灭火设备与灭火剂实验室组 BU 范围 范围 PB/BU/701/8 edycja / edition 1 z / of 21.04.2023","test_object_zh":"手提式灭火器"},{"_id":"6a7d78810636ba417e419c9c","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Masa środka gaśniczego (masa napełnienia) / mass of extinguishing agent (zakres 20-300 kg)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Masa środka gaśniczego (masa napełnienia) / mass of extinguishing agent (zakres 20-300 kg)","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Masa środka gaśniczego (masa napełnienia) / mass of extinguishing agent (zakres 20-300 kg) PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Masa srodka gasniczego (masa napelnienia) / mass of extinguishing agent (zakres 20-300 kg) PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Mass of extinguishing agent (filling mass) (range 20-300 kg)","search_en":"Mobile fire extinguisher Mass of extinguishing agent (filling mass) (range 20-300 kg) Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419c9d","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Szczelność: / tightness: - metodą ubytku masy/ gravimetric method - metodą ubytku ciśnienia/ pressure loss method","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność: / tightness: - metodą ubytku masy/ gravimetric method - metodą ubytku ciśnienia/ pressure loss method","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Szczelność: / tightness: - metodą ubytku masy/ gravimetric method - metodą ubytku ciśnienia/ pressure loss method PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Szczelnosc: / tightness: - metoda ubytku masy/ gravimetric method - metoda ubytku cisnienia/ pressure loss method PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Tightness: - gravimetric method - pressure loss method","search_en":"Mobile fire extinguisher Tightness: - gravimetric method - pressure loss method Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419c9e","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Długość węża i łącznika / hose and coupling","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Długość węża i łącznika / hose and coupling","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Długość węża i łącznika / hose and coupling PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Dlugosc weza i lacznika / hose and coupling PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Length of hose and coupling","search_en":"Mobile fire extinguisher Length of hose and coupling Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419c9f","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Wymiary otworów filtra dla gaśnic wodnych / dimension of filter for water based extinguishers","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary otworów filtra dla gaśnic wodnych / dimension of filter for water based extinguishers","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Wymiary otworów filtra dla gaśnic wodnych / dimension of filter for water based extinguishers PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Wymiary otworow filtra dla gasnic wodnych / dimension of filter for water based extinguishers PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"dimension of filter for water based extinguishers","search_en":"Mobile fire extinguisher dimension of filter for water based extinguishers Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419ca0","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Długość rzutu strumienia / water jet range","parameters":[{"name":"Zakres","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm"},{"name":"Scope","range":"- linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Długość rzutu strumienia / water jet range\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Długość rzutu strumienia / water jet range\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Dlugosc rzutu strumienia / water jet range\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary katowe 0-90º - Srednica 0,3-10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"water jet range","parameters_en":[{"name":"Range","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm"},{"name":"Scope","range":"- linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm"}],"search_en":"Mobile fire extinguisher water jet range Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm"},{"name":"范围","range":"- linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm"}],"search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419ca1","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Położenie robocze / Working position","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Położenie robocze / Working position","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Położenie robocze / Working position PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Polozenie robocze / Working position PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Working position","search_en":"Mobile fire extinguisher Working position Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419ca2","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Czas rozpoczęcia rozładowania / Start of discharge","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas rozpoczęcia rozładowania / Start of discharge","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Czas rozpoczęcia rozładowania / Start of discharge PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Czas rozpoczecia rozladowania / Start of discharge PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Start of discharge time","search_en":"Mobile fire extinguisher Start of discharge time Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419ca3","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Czas działania / Operation time","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas działania / Operation time","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Czas działania / Operation time PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Czas dzialania / Operation time PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Operation time","search_en":"Mobile fire extinguisher Operation time Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419ca4","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Maksymalna pozostałość środka gaśniczego / Maximum residue of extinguishing agent","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Maksymalna pozostałość środka gaśniczego / Maximum residue of extinguishing agent","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Maksymalna pozostałość środka gaśniczego / Maximum residue of extinguishing agent PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Maksymalna pozostalosc srodka gasniczego / Maximum residue of extinguishing agent PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Maximum residue of extinguishing agent","search_en":"Mobile fire extinguisher Maximum residue of extinguishing agent Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419ca5","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Urządzenie uruchamiające i sterujące strumieniem środka gaśniczego / Operation and emission control devices","parameters":[{"name":"Zakres","range":"(0 - 500) N"},{"name":"Scope","range":"(0 – 500) N"}],"technique":null,"techniques":[],"computed":[],"activity":"Urządzenie uruchamiające i sterujące strumieniem środka gaśniczego / Operation and emission control devices\nZakres:\nZakres (0 - 500) N\nScope (0 – 500) N","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Urządzenie uruchamiające i sterujące strumieniem środka gaśniczego / Operation and emission control devices\nZakres:\nZakres (0 - 500) N\nScope (0 – 500) N PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Urzadzenie uruchamiajace i sterujace strumieniem srodka gasniczego / Operation and emission control devices\nZakres:\nZakres (0 - 500) N\nScope (0 – 500) N PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Operation and extinguishing agent emission control devices","parameters_en":[{"name":"Range","range":"(0 - 500) N"},{"name":"Scope","range":"(0 – 500) N"}],"search_en":"Mobile fire extinguisher Operation and extinguishing agent emission control devices Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0 - 500) N"},{"name":"范围","range":"(0 – 500) N"}],"search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419ca6","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Siła wymagana do odbezpieczenia urządzenia zabezpieczającego / force necessary to unlock safety device","parameters":[{"name":"Zakres","range":"(0-500) N"},{"name":"Scope","range":"(0-500) N"}],"technique":null,"techniques":[],"computed":[],"activity":"Siła wymagana do odbezpieczenia urządzenia zabezpieczającego / force necessary to unlock safety device\nZakres:\nZakres (0-500) N\nScope (0-500) N","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Siła wymagana do odbezpieczenia urządzenia zabezpieczającego / force necessary to unlock safety device\nZakres:\nZakres (0-500) N\nScope (0-500) N PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Sila wymagana do odbezpieczenia urzadzenia zabezpieczajacego / force necessary to unlock safety device\nZakres:\nZakres (0-500) N\nScope (0-500) N PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"force necessary to unlock safety device","parameters_en":[{"name":"Range","range":"(0-500) N"},{"name":"Scope","range":"(0-500) N"}],"search_en":"Mobile fire extinguisher force necessary to unlock safety device Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0-500) N"},{"name":"范围","range":"(0-500) N"}],"search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419ca7","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Kolor (barwa) / colour","parameters":[],"technique":"Metoda wzorników","techniques":["Metoda wzorników"],"computed":[],"activity":"Kolor (barwa) / colour\nMetoda wzorników","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Kolor (barwa) / colour\nMetoda wzorników PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Kolor (barwa) / colour\nMetoda wzornikow PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Colour","search_en":"Mobile fire extinguisher Colour Templates method Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","technique_en":"Templates method","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 样板法 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器","technique_zh":"样板法"},{"_id":"6a7d78810636ba417e419ca8","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Pomiar wymiarów geometrycznych / Geometric dimensions","parameters":[{"name":"Zakres","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm"},{"name":"Scope","range":"- linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar wymiarów geometrycznych / Geometric dimensions\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm","reference":"PB/BU/702/2 edycja / edition 1 z / of 21.04.2023","norm_bases":["PB/BU/702/2 edycja / edition 1 z / of 21.04.2023"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Pomiar wymiarów geometrycznych / Geometric dimensions\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm PB/BU/702/2 edycja / edition 1 z / of 21.04.2023 Gasnice przewozne / Mobile fire extinguisher Pomiar wymiarow geometrycznych / Geometric dimensions\nZakres:\nZakres - Wymiary liniowe do 20000 mm - Wymiary katowe 0-90º - Srednica 0,3-10 mm\nScope - linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm PB/BU/702/2 edycja / edition 1 z / of 21.04.2023","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Measurement of geometric dimensions / Geometric dimensions","parameters_en":[{"name":"Range","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm"},{"name":"Scope","range":"- linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm"}],"search_en":"Mobile fire extinguisher Measurement of geometric dimensions / Geometric dimensions Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PB/BU/702/2 edycja / edition 1 z / of 21.04.2023","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"- Wymiary liniowe do 20000 mm - Wymiary kątowe 0-90º - Średnica 0,3-10 mm"},{"name":"范围","range":"- linear dimensions to 20000 mm - angular dimensions 0-90º - diameter 0,3-10 mm"}],"search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU 范围 范围 PB/BU/702/2 edycja / edition 1 z / of 21.04.2023","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419ca9","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Energia niezbędna do uruchomienia (2 J) / Energy required to trigger (2J)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Energia niezbędna do uruchomienia (2 J) / Energy required to trigger (2J)","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Energia niezbędna do uruchomienia (2 J) / Energy required to trigger (2J) PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Energia niezbedna do uruchomienia (2 J) / Energy required to trigger (2J) PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Energy required to trigger (2J)","search_en":"Mobile fire extinguisher Energy required to trigger (2J) Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419caa","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Efektywny zakres temperatur działania (-40 do +60) °C / Effective temperaturę range of operation (-40 to +60) °C","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Efektywny zakres temperatur działania (-40 do +60) °C / Effective temperaturę range of operation (-40 to +60) °C","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Efektywny zakres temperatur działania (-40 do +60) °C / Effective temperaturę range of operation (-40 to +60) °C PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Efektywny zakres temperatur dzialania (-40 do +60) °C / Effective temperature range of operation (-40 to +60) °C PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Effective temperature range of operation (-40 to +60) °C","search_en":"Mobile fire extinguisher Effective temperature range of operation (-40 to +60) °C Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419cab","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Badanie korozji zewnętrznej / External corrosion test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie korozji zewnętrznej / External corrosion test","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Badanie korozji zewnętrznej / External corrosion test PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Badanie korozji zewnetrznej / External corrosion test PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"External corrosion test / External corrosion test","search_en":"Mobile fire extinguisher External corrosion test / External corrosion test Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419cac","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Badanie korozji wewnętrznej gaśnic wodnych / Internal corrosion test – water based fire extinguishers","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie korozji wewnętrznej gaśnic wodnych / Internal corrosion test – water based fire extinguishers","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Badanie korozji wewnętrznej gaśnic wodnych / Internal corrosion test – water based fire extinguishers PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Badanie korozji wewnetrznej gasnic wodnych / Internal corrosion test – water based fire extinguishers PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Internal corrosion test of water based fire extinguishers / Internal corrosion test – water based fire extinguishers","search_en":"Mobile fire extinguisher Internal corrosion test of water based fire extinguishers / Internal corrosion test – water based fire extinguishers Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419cad","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Wielkość pól, liter i piktogramów na etykiecie / Size of fields, letters and pictograms on the label","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wielkość pól, liter i piktogramów na etykiecie / Size of fields, letters and pictograms on the label","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Wielkość pól, liter i piktogramów na etykiecie / Size of fields, letters and pictograms on the label PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Wielkosc pol, liter i piktogramow na etykiecie / Size of fields, letters and pictograms on the label PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Size of fields, letters and pictograms on the label / Size of fields, letters and pictograms on the label","search_en":"Mobile fire extinguisher Size of fields, letters and pictograms on the label / Size of fields, letters and pictograms on the label Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419cae","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Minimalna skutecznosc gasnicza – ocena pozaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Minimum extinguishing efficiency – class A fire rating","search_en":"Mobile fire extinguisher Minimum extinguishing efficiency – class A fire rating Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419caf","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Minimalna skutecznosc gasnicza – ocena pozaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Minimum extinguishing efficiency – class B fire rating","search_en":"Mobile fire extinguisher Minimum extinguishing efficiency – class B fire rating Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419cb0","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Badanie dielektryczne / Dielectric test for water based fire extinguishers","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie dielektryczne / Dielectric test for water based fire extinguishers","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Badanie dielektryczne / Dielectric test for water based fire extinguishers PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Badanie dielektryczne / Dielectric test for water based fire extinguishers PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Dielectric test / Dielectric test for water based fire extinguishers","search_en":"Mobile fire extinguisher Dielectric test / Dielectric test for water based fire extinguishers Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419cb1","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguisher","methodology":"Badanie 1000 cykli wskaźnika ciśnienia / Test of 1000 pressure indicator cycles","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie 1000 cykli wskaźnika ciśnienia / Test of 1000 pressure indicator cycles","reference":"PN-EN 1866-1:2010 (EN 1866-1:2007)","norm_bases":["PN-EN 1866-1:2010 (EN 1866-1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguisher Badanie 1000 cykli wskaźnika ciśnienia / Test of 1000 pressure indicator cycles PN-EN 1866-1:2010 (EN 1866-1:2007) Gasnice przewozne / Mobile fire extinguisher Badanie 1000 cykli wskaznika cisnienia / Test of 1000 pressure indicator cycles PN-EN 1866-1:2010 (EN 1866-1:2007)","categories":["other"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Test of 1000 pressure indicator cycles","search_en":"Mobile fire extinguisher Test of 1000 pressure indicator cycles Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_en":"Mobile fire extinguisher","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"推车式灭火器 灭火设备与灭火剂实验室组 BU PN-EN 1866-1:2010 (EN 1866-1:2007)","test_object_zh":"推车式灭火器"},{"_id":"6a7d78810636ba417e419cb2","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Skuteczność gaśnicza / Extinguishing efficiency","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność gaśnicza / Extinguishing efficiency","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Skuteczność gaśnicza / Extinguishing efficiency PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Skutecznosc gasnicza / Extinguishing efficiency PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Extinguishing efficiency / Extinguishing efficiency","search_en":"Portable aerosol dispenser Extinguishing efficiency / Extinguishing efficiency Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cb3","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Zabezpieczenie: - pozycja pracy - wyposażenie aerozolu / Safety device: -work position -subassemblies","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zabezpieczenie: - pozycja pracy - wyposażenie aerozolu / Safety device: -work position -subassemblies","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Zabezpieczenie: - pozycja pracy - wyposażenie aerozolu / Safety device: -work position -subassemblies PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Zabezpieczenie: - pozycja pracy - wyposazenie aerozolu / Safety device: -work position -subassemblies PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Safety device: -work position -subassemblies","search_en":"Portable aerosol dispenser Safety device: -work position -subassemblies Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cb4","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Siła niezbędna do usunięcia zabezpieczenia / Force necessary to unlock safety device","parameters":[{"name":"Zakres","range":"(5-50) N"},{"name":"Scope","range":"(5-50) N"}],"technique":null,"techniques":[],"computed":[],"activity":"Siła niezbędna do usunięcia zabezpieczenia / Force necessary to unlock safety device\nZakres:\nZakres (5-50) N\nScope (5-50) N","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Siła niezbędna do usunięcia zabezpieczenia / Force necessary to unlock safety device\nZakres:\nZakres (5-50) N\nScope (5-50) N PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Sila niezbedna do usuniecia zabezpieczenia / Force necessary to unlock safety device\nZakres:\nZakres (5-50) N\nScope (5-50) N PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Force necessary to unlock safety device","parameters_en":[{"name":"Range","range":"(5-50) N"},{"name":"Scope","range":"(5-50) N"}],"search_en":"Portable aerosol dispenser Force necessary to unlock safety device Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(5-50) N"},{"name":"范围","range":"(5-50) N"}],"search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cb5","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Siła uruchomienia / Force necessary to actuation","parameters":[{"name":"Zakres","range":"(0-50) N"},{"name":"Scope","range":"(0-50) N"}],"technique":null,"techniques":[],"computed":[],"activity":"Siła uruchomienia / Force necessary to actuation\nZakres:\nZakres (0-50) N\nScope (0-50) N","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Siła uruchomienia / Force necessary to actuation\nZakres:\nZakres (0-50) N\nScope (0-50) N PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Sila uruchomienia / Force necessary to actuation\nZakres:\nZakres (0-50) N\nScope (0-50) N PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Force necessary to actuation","parameters_en":[{"name":"Range","range":"(0-50) N"},{"name":"Scope","range":"(0-50) N"}],"search_en":"Portable aerosol dispenser Force necessary to actuation Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0-50) N"},{"name":"范围","range":"(0-50) N"}],"search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cb6","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Odporność na korozję zewnętrzną/ Resistance to external corrosion","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na korozję zewnętrzną/ Resistance to external corrosion","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Odporność na korozję zewnętrzną/ Resistance to external corrosion PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Odpornosc na korozje zewnetrzna/ Resistance to external corrosion PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to external corrosion","search_en":"Portable aerosol dispenser Resistance to external corrosion Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cb7","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Odporność na korozję wewnętrzną/ Resistance to internal corrosion","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na korozję wewnętrzną/ Resistance to internal corrosion","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Odporność na korozję wewnętrzną/ Resistance to internal corrosion PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Odpornosc na korozje wewnetrzna/ Resistance to internal corrosion PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to internal corrosion","search_en":"Portable aerosol dispenser Resistance to internal corrosion Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cb8","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Stabilność chemiczna i ciśnieniowa/ Chemical and pressure stability","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stabilność chemiczna i ciśnieniowa/ Chemical and pressure stability","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Stabilność chemiczna i ciśnieniowa/ Chemical and pressure stability PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Stabilnosc chemiczna i cisnieniowa/ Chemical and pressure stability PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Chemical and pressure stability","search_en":"Portable aerosol dispenser Chemical and pressure stability Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cb9","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Odporność na uderzenia/ Impact resistance","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na uderzenia/ Impact resistance","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Odporność na uderzenia/ Impact resistance PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Odpornosc na uderzenia/ Impact resistance PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Impact resistance","search_en":"Portable aerosol dispenser Impact resistance Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cba","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Odporność na wstrząsy i uderzenia mechaniczne/ Resistance to shock and mechanical damage","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wstrząsy i uderzenia mechaniczne/ Resistance to shock and mechanical damage","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Odporność na wstrząsy i uderzenia mechaniczne/ Resistance to shock and mechanical damage PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Odpornosc na wstrzasy i uderzenia mechaniczne/ Resistance to shock and mechanical damage PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to shock and mechanical damage","search_en":"Portable aerosol dispenser Resistance to shock and mechanical damage Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cbb","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Ciśnienie próbne / Test pressure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ciśnienie próbne / Test pressure","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Ciśnienie próbne / Test pressure PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Cisnienie probne / Test pressure PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Test pressure","search_en":"Portable aerosol dispenser Test pressure Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cbc","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Ciśnienie rozrywające / Burst pressure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ciśnienie rozrywające / Burst pressure","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Ciśnienie rozrywające / Burst pressure PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Cisnienie rozrywajace / Burst pressure PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Burst pressure","search_en":"Portable aerosol dispenser Burst pressure Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cbd","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Tolerancja napełnienia / Media tolerance","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Tolerancja napełnienia / Media tolerance","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Tolerancja napełnienia / Media tolerance PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Tolerancja napelnienia / Media tolerance PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Media tolerance","search_en":"Portable aerosol dispenser Media tolerance Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cbe","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Ciśnienie napełnienia/ Filling pressure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ciśnienie napełnienia/ Filling pressure","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Ciśnienie napełnienia/ Filling pressure PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Cisnienie napelnienia/ Filling pressure PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Filling pressure","search_en":"Portable aerosol dispenser Filling pressure Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cbf","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Maksymalne ciśnienie rozrywające / Maximum developed pressure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Maksymalne ciśnienie rozrywające / Maximum developed pressure","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Maksymalne ciśnienie rozrywające / Maximum developed pressure PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Maksymalne cisnienie rozrywajace / Maximum developed pressure PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Maximum developed pressure","search_en":"Portable aerosol dispenser Maximum developed pressure Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cc0","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Opóźnienie w działaniu/ Delay on operation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Opóźnienie w działaniu/ Delay on operation","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Opóźnienie w działaniu/ Delay on operation PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Opoznienie w dzialaniu/ Delay on operation PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Delay on operation","search_en":"Portable aerosol dispenser Delay on operation Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cc1","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Czas działania/ Duration of discharge","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas działania/ Duration of discharge","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Czas działania/ Duration of discharge PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Czas dzialania/ Duration of discharge PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Duration of discharge","search_en":"Portable aerosol dispenser Duration of discharge Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cc2","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Minimalne rozładowanie zawartości / Minimum discharge of contents","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Minimalne rozładowanie zawartości / Minimum discharge of contents","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Minimalne rozładowanie zawartości / Minimum discharge of contents PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Minimalne rozladowanie zawartosci / Minimum discharge of contents PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Minimum discharge of contents","search_en":"Portable aerosol dispenser Minimum discharge of contents Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cc3","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Utrzymanie ładunku po częściowym rozładunku/ Retention of charge following partial discharge","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Utrzymanie ładunku po częściowym rozładunku/ Retention of charge following partial discharge","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Utrzymanie ładunku po częściowym rozładunku/ Retention of charge following partial discharge PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Utrzymanie ladunku po czesciowym rozladunku/ Retention of charge following partial discharge PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Retention of charge following partial discharge","search_en":"Portable aerosol dispenser Retention of charge following partial discharge Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cc4","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Długość rzutu środka gaśniczego / Effective throw range","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Długość rzutu środka gaśniczego / Effective throw range","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Długość rzutu środka gaśniczego / Effective throw range PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Dlugosc rzutu srodka gasniczego / Effective throw range PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Effective throw range of the extinguishing agent","search_en":"Portable aerosol dispenser Effective throw range of the extinguishing agent Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cc5","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Kolor, barwa / Colour","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kolor, barwa / Colour","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Kolor, barwa / Colour PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Kolor, barwa / Colour PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Colour, hue / Colour","search_en":"Portable aerosol dispenser Colour, hue / Colour Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cc6","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Oznakowanie – informacje podstawowe / Marking – primary information","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Oznakowanie – informacje podstawowe / Marking – primary information","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Oznakowanie – informacje podstawowe / Marking – primary information PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Oznakowanie – informacje podstawowe / Marking – primary information PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Marking – primary information","search_en":"Portable aerosol dispenser Marking – primary information Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cc7","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Oznakowanie – informacje dodatkowe / Marking - secondary information","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Oznakowanie – informacje dodatkowe / Marking - secondary information","reference":"PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","norm_bases":["PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Oznakowanie – informacje dodatkowe / Marking - secondary information PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8 Przenosny dozownik aerozoli/ Portable aerosol dispenser Oznakowanie – informacje dodatkowe / Marking - secondary information PN-EN 16856:2020 Z wylaczeniem p.8 (EN 16856:2020) Except p.8","categories":["other"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Marking - secondary information","search_en":"Portable aerosol dispenser Marking - secondary information Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU PN-EN 16856:2020 Z wyłączeniem p.8 (EN 16856:2020) Except p.8","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cc8","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Minimalna skuteczność gaśnicza grupy B/ Minimum extinguishing efficiency – class B fire rating","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Minimalna skuteczność gaśnicza grupy B/ Minimum extinguishing efficiency – class B fire rating","reference":"BS 6165:2019 zał. H5","norm_bases":["BS 6165:2019 zał. H5"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Minimalna skuteczność gaśnicza grupy B/ Minimum extinguishing efficiency – class B fire rating BS 6165:2019 zał. H5 Przenosny dozownik aerozoli/ Portable aerosol dispenser Minimalna skutecznosc gasnicza grupy B/ Minimum extinguishing efficiency – class B fire rating BS 6165:2019 zal. H5","categories":["other"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Minimum extinguishing efficiency – class B fire rating","search_en":"Portable aerosol dispenser Minimum extinguishing efficiency – class B fire rating Fire Extinguishing Equipment and Agents Laboratories Group BU BS 6165:2019 zał. H5","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU BS 6165:2019 zał. H5","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cc9","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Minimalna skuteczność gaśnicza grupy F/ Minimum extinguishing efficiency – class F fire rating","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Minimalna skuteczność gaśnicza grupy F/ Minimum extinguishing efficiency – class F fire rating","reference":"BS 6165:2019 zał. H6","norm_bases":["BS 6165:2019 zał. H6"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Minimalna skuteczność gaśnicza grupy F/ Minimum extinguishing efficiency – class F fire rating BS 6165:2019 zał. H6 Przenosny dozownik aerozoli/ Portable aerosol dispenser Minimalna skutecznosc gasnicza grupy F/ Minimum extinguishing efficiency – class F fire rating BS 6165:2019 zal. H6","categories":["other"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Minimum extinguishing efficiency – class F fire rating","search_en":"Portable aerosol dispenser Minimum extinguishing efficiency – class F fire rating Fire Extinguishing Equipment and Agents Laboratories Group BU BS 6165:2019 zał. H6","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU BS 6165:2019 zał. H6","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419cca","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Przenośny dozownik aerozoli/ Portable aerosol dispenser","methodology":"Minimalna skuteczność gaśnicza grupy A / Minimum extinguishing efficiency – class A fire rating","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Minimalna skuteczność gaśnicza grupy A / Minimum extinguishing efficiency – class A fire rating","reference":"BS 6165:2019 zał. H4","norm_bases":["BS 6165:2019 zał. H4"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przenośny dozownik aerozoli/ Portable aerosol dispenser Minimalna skuteczność gaśnicza grupy A / Minimum extinguishing efficiency – class A fire rating BS 6165:2019 zał. H4 Przenosny dozownik aerozoli/ Portable aerosol dispenser Minimalna skutecznosc gasnicza grupy A / Minimum extinguishing efficiency – class A fire rating BS 6165:2019 zal. H4","categories":["other"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Minimum extinguishing efficiency – class A fire rating","search_en":"Portable aerosol dispenser Minimum extinguishing efficiency – class A fire rating Fire Extinguishing Equipment and Agents Laboratories Group BU BS 6165:2019 zał. H4","test_object_en":"Portable aerosol dispenser","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"便携式气雾喷射器 灭火设备与灭火剂实验室组 BU BS 6165:2019 zał. H4","test_object_zh":"便携式气雾喷射器"},{"_id":"6a7d78810636ba417e419ccb","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Koce gaśnicze / Fire blankets","methodology":"Wymiary koca / Dimensions of the blanket","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary koca / Dimensions of the blanket","reference":"PN-EN 1869:2019 (EN 1869:2019)","norm_bases":["PN-EN 1869:2019 (EN 1869:2019)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koce gaśnicze / Fire blankets Wymiary koca / Dimensions of the blanket PN-EN 1869:2019 (EN 1869:2019) Koce gasnicze / Fire blankets Wymiary koca / Dimensions of the blanket PN-EN 1869:2019 (EN 1869:2019)","categories":["other"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Dimensions of the blanket","search_en":"Fire blankets Dimensions of the blanket Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1869:2019 (EN 1869:2019)","test_object_en":"Fire blankets","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火毯 / Fire blankets 灭火设备与灭火剂实验室组 BU PN-EN 1869:2019 (EN 1869:2019)","test_object_zh":"灭火毯 / Fire blankets"},{"_id":"6a7d78810636ba417e419ccc","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Koce gaśnicze / Fire blankets","methodology":"Masa koca / The mass of the blanket","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Masa koca / The mass of the blanket","reference":"PN-EN 1869:2019 (EN 1869:2019)","norm_bases":["PN-EN 1869:2019 (EN 1869:2019)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koce gaśnicze / Fire blankets Masa koca / The mass of the blanket PN-EN 1869:2019 (EN 1869:2019) Koce gasnicze / Fire blankets Masa koca / The mass of the blanket PN-EN 1869:2019 (EN 1869:2019)","categories":["other"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"The mass of the blanket","search_en":"Fire blankets The mass of the blanket Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1869:2019 (EN 1869:2019)","test_object_en":"Fire blankets","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火毯 / Fire blankets 灭火设备与灭火剂实验室组 BU PN-EN 1869:2019 (EN 1869:2019)","test_object_zh":"灭火毯 / Fire blankets"},{"_id":"6a7d78810636ba417e419ccd","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Koce gaśnicze / Fire blankets","methodology":"Zrolowanie koca / Rolling of the blanket","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zrolowanie koca / Rolling of the blanket","reference":"PN-EN 1869:2019 (EN 1869:2019)","norm_bases":["PN-EN 1869:2019 (EN 1869:2019)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koce gaśnicze / Fire blankets Zrolowanie koca / Rolling of the blanket PN-EN 1869:2019 (EN 1869:2019) Koce gasnicze / Fire blankets Zrolowanie koca / Rolling of the blanket PN-EN 1869:2019 (EN 1869:2019)","categories":["other"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Rolling of the blanket","search_en":"Fire blankets Rolling of the blanket Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1869:2019 (EN 1869:2019)","test_object_en":"Fire blankets","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火毯 / Fire blankets 灭火设备与灭火剂实验室组 BU PN-EN 1869:2019 (EN 1869:2019)","test_object_zh":"灭火毯 / Fire blankets"},{"_id":"6a7d78810636ba417e419cce","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Koce gaśnicze / Fire blankets","methodology":"Rozwinięcie koca / Unfolding of the fire blanket","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rozwinięcie koca / Unfolding of the fire blanket","reference":"PN-EN 1869:2019 (EN 1869:2019)","norm_bases":["PN-EN 1869:2019 (EN 1869:2019)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koce gaśnicze / Fire blankets Rozwinięcie koca / Unfolding of the fire blanket PN-EN 1869:2019 (EN 1869:2019) Koce gasnicze / Fire blankets Rozwiniecie koca / Unfolding of the fire blanket PN-EN 1869:2019 (EN 1869:2019)","categories":["other"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Unfolding of the fire blanket","search_en":"Fire blankets Unfolding of the fire blanket Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1869:2019 (EN 1869:2019)","test_object_en":"Fire blankets","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火毯 / Fire blankets 灭火设备与灭火剂实验室组 BU PN-EN 1869:2019 (EN 1869:2019)","test_object_zh":"灭火毯 / Fire blankets"},{"_id":"6a7d78810636ba417e419ccf","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Koce gaśnicze / Fire blankets","methodology":"Opór elektryczny / Electrical resistance of the blanket material","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Opór elektryczny / Electrical resistance of the blanket material","reference":"PN-EN 1869:2019 (EN 1869:2019)","norm_bases":["PN-EN 1869:2019 (EN 1869:2019)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koce gaśnicze / Fire blankets Opór elektryczny / Electrical resistance of the blanket material PN-EN 1869:2019 (EN 1869:2019) Koce gasnicze / Fire blankets Opor elektryczny / Electrical resistance of the blanket material PN-EN 1869:2019 (EN 1869:2019)","categories":["materials"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Electrical resistance of the blanket material","search_en":"Fire blankets Electrical resistance of the blanket material Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1869:2019 (EN 1869:2019)","test_object_en":"Fire blankets","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火毯 / Fire blankets 灭火设备与灭火剂实验室组 BU PN-EN 1869:2019 (EN 1869:2019)","test_object_zh":"灭火毯 / Fire blankets"},{"_id":"6a7d78810636ba417e419cd0","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Koce gaśnicze / Fire blankets","methodology":"Właściwości gaśnicze oleju spożywczego i heptanu / Fire performance for cooking oil and heptane","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości gaśnicze oleju spożywczego i heptanu / Fire performance for cooking oil and heptane","reference":"PN-EN 1869:2019 (EN 1869:2019)","norm_bases":["PN-EN 1869:2019 (EN 1869:2019)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koce gaśnicze / Fire blankets Właściwości gaśnicze oleju spożywczego i heptanu / Fire performance for cooking oil and heptane PN-EN 1869:2019 (EN 1869:2019) Koce gasnicze / Fire blankets Wlasciwosci gasnicze oleju spozywczego i heptanu / Fire performance for cooking oil and heptane PN-EN 1869:2019 (EN 1869:2019)","categories":["petro"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Fire performance for cooking oil and heptane","search_en":"Fire blankets Fire performance for cooking oil and heptane Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1869:2019 (EN 1869:2019)","test_object_en":"Fire blankets","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火毯 / Fire blankets 灭火设备与灭火剂实验室组 BU PN-EN 1869:2019 (EN 1869:2019)","test_object_zh":"灭火毯 / Fire blankets"},{"_id":"6a7d78810636ba417e419cd1","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Koce gaśnicze / Fire blankets","methodology":"Krawędzie koca / Edges of the blanket","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Krawędzie koca / Edges of the blanket","reference":"PN-EN 1869:2019 (EN 1869:2019)","norm_bases":["PN-EN 1869:2019 (EN 1869:2019)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koce gaśnicze / Fire blankets Krawędzie koca / Edges of the blanket PN-EN 1869:2019 (EN 1869:2019) Koce gasnicze / Fire blankets Krawedzie koca / Edges of the blanket PN-EN 1869:2019 (EN 1869:2019)","categories":["other"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Edges of the blanket","search_en":"Fire blankets Edges of the blanket Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1869:2019 (EN 1869:2019)","test_object_en":"Fire blankets","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火毯 / Fire blankets 灭火设备与灭火剂实验室组 BU PN-EN 1869:2019 (EN 1869:2019)","test_object_zh":"灭火毯 / Fire blankets"},{"_id":"6a7d78810636ba417e419cd2","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Koce gaśnicze / Fire blankets","methodology":"Wielkość pól i liter na etykiecie / Size of fields, letters and pictograms on the label","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wielkość pól i liter na etykiecie / Size of fields, letters and pictograms on the label","reference":"PN-EN 1869:2019 (EN 1869:2019)","norm_bases":["PN-EN 1869:2019 (EN 1869:2019)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koce gaśnicze / Fire blankets Wielkość pól i liter na etykiecie / Size of fields, letters and pictograms on the label PN-EN 1869:2019 (EN 1869:2019) Koce gasnicze / Fire blankets Wielkosc pol i liter na etykiecie / Size of fields, letters and pictograms on the label PN-EN 1869:2019 (EN 1869:2019)","categories":["other"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Size of fields, letters and pictograms on the label","search_en":"Fire blankets Size of fields, letters and pictograms on the label Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1869:2019 (EN 1869:2019)","test_object_en":"Fire blankets","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火毯 / Fire blankets 灭火设备与灭火剂实验室组 BU PN-EN 1869:2019 (EN 1869:2019)","test_object_zh":"灭火毯 / Fire blankets"},{"_id":"6a7d78810636ba417e419cd3","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Koce gaśnicze / Fire blankets","methodology":"Uchwyty koca / Blanket handles","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Uchwyty koca / Blanket handles","reference":"PN-EN 1869:2019 (EN 1869:2019)","norm_bases":["PN-EN 1869:2019 (EN 1869:2019)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koce gaśnicze / Fire blankets Uchwyty koca / Blanket handles PN-EN 1869:2019 (EN 1869:2019) Koce gasnicze / Fire blankets Uchwyty koca / Blanket handles PN-EN 1869:2019 (EN 1869:2019)","categories":["other"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Blanket handles","search_en":"Fire blankets Blanket handles Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1869:2019 (EN 1869:2019)","test_object_en":"Fire blankets","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火毯 / Fire blankets 灭火设备与灭火剂实验室组 BU PN-EN 1869:2019 (EN 1869:2019)","test_object_zh":"灭火毯 / Fire blankets"},{"_id":"6a7d78810636ba417e419cd4","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Wyroby zawierające elementy metalowe / Products containing metal components","methodology":"Odporność na działanie obojętnej mgły solnej (metoda NSS) / Resistance to neutral salt spray (NSS method)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie obojętnej mgły solnej (metoda NSS) / Resistance to neutral salt spray (NSS method)","reference":"PN-EN ISO 9227:2023 (EN ISO 9227:2022)","norm_bases":["PN-EN ISO 9227:2023 (EN ISO 9227:2022)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby zawierające elementy metalowe / Products containing metal components Odporność na działanie obojętnej mgły solnej (metoda NSS) / Resistance to neutral salt spray (NSS method) PN-EN ISO 9227:2023 (EN ISO 9227:2022) Wyroby zawierajace elementy metalowe / Products containing metal components Odpornosc na dzialanie obojetnej mgly solnej (metoda NSS) / Resistance to neutral salt spray (NSS method) PN-EN ISO 9227:2023 (EN ISO 9227:2022)","categories":["materials"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to neutral salt spray (NSS method)","search_en":"Products containing metal components Resistance to neutral salt spray (NSS method) Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN ISO 9227:2023 (EN ISO 9227:2022)","test_object_en":"Products containing metal components","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU PN-EN ISO 9227:2023 (EN ISO 9227:2022)"},{"_id":"6a7d78810636ba417e419cd5","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Urządzenia gaśnicze / Extinguishing devices","methodology":"Skuteczność gaśnicza – pożary grupy A i B / Test fire performance – class A and B fire rating","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność gaśnicza – pożary grupy A i B / Test fire performance – class A and B fire rating","reference":"PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","norm_bases":["PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia gaśnicze / Extinguishing devices Skuteczność gaśnicza – pożary grupy A i B / Test fire performance – class A and B fire rating PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007) Urzadzenia gasnicze / Extinguishing devices Skutecznosc gasnicza – pozary grupy A i B / Test fire performance – class A and B fire rating PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","categories":["other"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Test fire performance – class A and B fire rating","search_en":"Extinguishing devices Test fire performance – class A and B fire rating Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)","test_object_en":"Extinguishing devices","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU PN-EN 3-7+A1:2008 (EN 3-7:2004+A1:2007)"},{"_id":"6a7d78810636ba417e419cd6","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Stojaki hydrantowe / Standpipes","methodology":"Wymiary / Dimensions","parameters":[{"name":"Zakres","range":"(5,95 - 3000) mm"},{"name":"Scope","range":"(5,95 - 3000) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary / Dimensions\nZakres:\nZakres (5,95 - 3000) mm\nScope (5,95 - 3000) mm","reference":"PN-73/M-51154, p. 5.4.2 | PN-M-51154:2015-04 p.5.3","norm_bases":["PN-73/M-51154, p. 5.4.2","PN-M-51154:2015-04 p.5.3"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stojaki hydrantowe / Standpipes Wymiary / Dimensions\nZakres:\nZakres (5,95 - 3000) mm\nScope (5,95 - 3000) mm PN-73/M-51154, p. 5.4.2 | PN-M-51154:2015-04 p.5.3 Stojaki hydrantowe / Standpipes Wymiary / Dimensions\nZakres:\nZakres (5,95 - 3000) mm\nScope (5,95 - 3000) mm PN-73/M-51154, p. 5.4.2 | PN-M-51154:2015-04 p.5.3","categories":["other"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"(5,95 - 3000) mm"},{"name":"Scope","range":"(5,95 - 3000) mm"}],"search_en":"Standpipes Dimensions Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-73/M-51154, p. 5.4.2 | PN-M-51154:2015-04 p.5.3","test_object_en":"Standpipes","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(5,95 - 3000) mm"},{"name":"范围","range":"(5,95 - 3000) mm"}],"search_zh":"消火栓立管 / Standpipes 尺寸 / Dimensions 灭火设备与灭火剂实验室组 BU 范围 范围 PN-73/M-51154, p. 5.4.2 | PN-M-51154:2015-04 p.5.3","test_object_zh":"消火栓立管 / Standpipes","methodology_zh":"尺寸 / Dimensions"},{"_id":"6a7d78810636ba417e419cd7","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Stojaki hydrantowe / Standpipes","methodology":"Masa / Mass","parameters":[{"name":"Zakres","range":"(0,02 - 24) kg"},{"name":"Scope","range":"(0,02 - 24) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"Masa / Mass\nZakres:\nZakres (0,02 - 24) kg\nScope (0,02 - 24) kg","reference":"PN-73/M-51154, p. 5.4.3 | PN-M-51154:2015-04 p.5.4","norm_bases":["PN-73/M-51154, p. 5.4.3","PN-M-51154:2015-04 p.5.4"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stojaki hydrantowe / Standpipes Masa / Mass\nZakres:\nZakres (0,02 - 24) kg\nScope (0,02 - 24) kg PN-73/M-51154, p. 5.4.3 | PN-M-51154:2015-04 p.5.4 Stojaki hydrantowe / Standpipes Masa / Mass\nZakres:\nZakres (0,02 - 24) kg\nScope (0,02 - 24) kg PN-73/M-51154, p. 5.4.3 | PN-M-51154:2015-04 p.5.4","categories":["other"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Mass","parameters_en":[{"name":"Range","range":"(0,02 - 24) kg"},{"name":"Scope","range":"(0,02 - 24) kg"}],"search_en":"Standpipes Mass Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-73/M-51154, p. 5.4.3 | PN-M-51154:2015-04 p.5.4","test_object_en":"Standpipes","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0,02 - 24) kg"},{"name":"范围","range":"(0,02 - 24) kg"}],"search_zh":"消火栓立管 / Standpipes 灭火设备与灭火剂实验室组 BU 范围 范围 PN-73/M-51154, p. 5.4.3 | PN-M-51154:2015-04 p.5.4","test_object_zh":"消火栓立管 / Standpipes"},{"_id":"6a7d78810636ba417e419cd8","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Stojaki hydrantowe / Standpipes","methodology":"Szczelność stojaka / Stand tightness","parameters":[{"name":"Zakres","range":"do 10 MPa"},{"name":"Scope","range":"to 10 MPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność stojaka / Stand tightness\nZakres:\nZakres do 10 MPa\nScope to 10 MPa","reference":"PN-73/M-51154, p. 5.4.5 | PN-M-51154:2015-04 p.5.5","norm_bases":["PN-73/M-51154, p. 5.4.5","PN-M-51154:2015-04 p.5.5"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stojaki hydrantowe / Standpipes Szczelność stojaka / Stand tightness\nZakres:\nZakres do 10 MPa\nScope to 10 MPa PN-73/M-51154, p. 5.4.5 | PN-M-51154:2015-04 p.5.5 Stojaki hydrantowe / Standpipes Szczelnosc stojaka / Stand tightness\nZakres:\nZakres do 10 MPa\nScope to 10 MPa PN-73/M-51154, p. 5.4.5 | PN-M-51154:2015-04 p.5.5","categories":["other"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Stand tightness","parameters_en":[{"name":"Range","range":"do 10 MPa"},{"name":"Scope","range":"to 10 MPa"}],"search_en":"Standpipes Stand tightness Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-73/M-51154, p. 5.4.5 | PN-M-51154:2015-04 p.5.5","test_object_en":"Standpipes","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"do 10 MPa"},{"name":"范围","range":"to 10 MPa"}],"search_zh":"消火栓立管 / Standpipes 灭火设备与灭火剂实验室组 BU 范围 范围 PN-73/M-51154, p. 5.4.5 | PN-M-51154:2015-04 p.5.5","test_object_zh":"消火栓立管 / Standpipes"},{"_id":"6a7d78810636ba417e419cd9","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Stojaki hydrantowe / Standpipes","methodology":"Działanie - badanie funkcjonalne / Operation - functional testing","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Działanie - badanie funkcjonalne / Operation - functional testing","reference":"PN-73/M-51154, p. 5.4.6 | PN-M-51154:2015-04 p.5.2","norm_bases":["PN-73/M-51154, p. 5.4.6","PN-M-51154:2015-04 p.5.2"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stojaki hydrantowe / Standpipes Działanie - badanie funkcjonalne / Operation - functional testing PN-73/M-51154, p. 5.4.6 | PN-M-51154:2015-04 p.5.2 Stojaki hydrantowe / Standpipes Dzialanie - badanie funkcjonalne / Operation - functional testing PN-73/M-51154, p. 5.4.6 | PN-M-51154:2015-04 p.5.2","categories":["other"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Operation - functional testing","search_en":"Standpipes Operation - functional testing Fire Extinguishing Equipment and Agents Laboratories Group BU PN-73/M-51154, p. 5.4.6 | PN-M-51154:2015-04 p.5.2","test_object_en":"Standpipes","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"消火栓立管 / Standpipes 灭火设备与灭火剂实验室组 BU PN-73/M-51154, p. 5.4.6 | PN-M-51154:2015-04 p.5.2","test_object_zh":"消火栓立管 / Standpipes"},{"_id":"6a7d78810636ba417e419cda","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Stojaki hydrantowe / Standpipes","methodology":"Szczepność - moment obrotowy Adhesion - torque","parameters":[{"name":"Zakres","range":"do 500 Nm"},{"name":"Scope","range":"to 500 Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczepność - moment obrotowy Adhesion - torque\nZakres:\nZakres do 500 Nm\nScope to 500 Nm","reference":"PN-73/M-51154, p. 5.4.7 | PN-M-51154:2015-04 p.5.6","norm_bases":["PN-73/M-51154, p. 5.4.7","PN-M-51154:2015-04 p.5.6"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stojaki hydrantowe / Standpipes Szczepność - moment obrotowy Adhesion - torque\nZakres:\nZakres do 500 Nm\nScope to 500 Nm PN-73/M-51154, p. 5.4.7 | PN-M-51154:2015-04 p.5.6 Stojaki hydrantowe / Standpipes Szczepnosc - moment obrotowy Adhesion - torque\nZakres:\nZakres do 500 Nm\nScope to 500 Nm PN-73/M-51154, p. 5.4.7 | PN-M-51154:2015-04 p.5.6","categories":["other"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Adhesion - torque","parameters_en":[{"name":"Range","range":"do 500 Nm"},{"name":"Scope","range":"to 500 Nm"}],"search_en":"Standpipes Adhesion - torque Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-73/M-51154, p. 5.4.7 | PN-M-51154:2015-04 p.5.6","test_object_en":"Standpipes","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"do 500 Nm"},{"name":"范围","range":"to 500 Nm"}],"search_zh":"消火栓立管 / Standpipes 灭火设备与灭火剂实验室组 BU 范围 范围 PN-73/M-51154, p. 5.4.7 | PN-M-51154:2015-04 p.5.6","test_object_zh":"消火栓立管 / Standpipes"},{"_id":"6a7d78810636ba417e419cdb","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty podziemne i nadziemne / Underground and pillar hydrants","methodology":"Wymiary / Dimensions","parameters":[{"name":"Zakres","range":"(0,001 - 5) m"},{"name":"Scope","range":"(0,001 - 5) m"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary / Dimensions\nZakres:\nZakres (0,001 - 5) m\nScope (0,001 - 5) m","reference":"PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.2 | PN-EN 14384:2009, p. 5.2 (EN 14339:2005, p. 5.2)","norm_bases":["PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016","PN-EN 14339:2009, p. 5.2","PN-EN 14384:2009, p. 5.2 (EN 14339:2005, p. 5.2)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty podziemne i nadziemne / Underground and pillar hydrants Wymiary / Dimensions\nZakres:\nZakres (0,001 - 5) m\nScope (0,001 - 5) m PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.2 | PN-EN 14384:2009, p. 5.2 (EN 14339:2005, p. 5.2) Hydranty podziemne i nadziemne / Underground and pillar hydrants Wymiary / Dimensions\nZakres:\nZakres (0,001 - 5) m\nScope (0,001 - 5) m PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.2 | PN-EN 14384:2009, p. 5.2 (EN 14339:2005, p. 5.2)","categories":["other"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"(0,001 - 5) m"},{"name":"Scope","range":"(0,001 - 5) m"}],"search_en":"Underground and pillar hydrants Dimensions Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.2 | PN-EN 14384:2009, p. 5.2 (EN 14339:2005, p. 5.2)","test_object_en":"Underground and pillar hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0,001 - 5) m"},{"name":"范围","range":"(0,001 - 5) m"}],"search_zh":"地下式与地上式消火栓 / Underground and pillar hydrants 尺寸 / Dimensions 灭火设备与灭火剂实验室组 BU 范围 范围 PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.2 | PN-EN 14384:2009, p. 5.2 (EN 14339:2005, p. 5.2)","test_object_zh":"地下式与地上式消火栓 / Underground and pillar hydrants","methodology_zh":"尺寸 / Dimensions"},{"_id":"6a7d78810636ba417e419cdc","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty podziemne i nadziemne / Underground and pillar hydrants","methodology":"Masa / Mass","parameters":[{"name":"Zakres","range":"(0,4 - 150) kg"},{"name":"Scope","range":"(0,4 - 150) kg"}],"technique":null,"techniques":[],"computed":[],"activity":"Masa / Mass\nZakres:\nZakres (0,4 - 150) kg\nScope (0,4 - 150) kg","reference":"PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016","norm_bases":["PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty podziemne i nadziemne / Underground and pillar hydrants Masa / Mass\nZakres:\nZakres (0,4 - 150) kg\nScope (0,4 - 150) kg PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 Hydranty podziemne i nadziemne / Underground and pillar hydrants Masa / Mass\nZakres:\nZakres (0,4 - 150) kg\nScope (0,4 - 150) kg PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016","categories":["other"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Mass","parameters_en":[{"name":"Range","range":"(0,4 - 150) kg"},{"name":"Scope","range":"(0,4 - 150) kg"}],"search_en":"Underground and pillar hydrants Mass Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016","test_object_en":"Underground and pillar hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0,4 - 150) kg"},{"name":"范围","range":"(0,4 - 150) kg"}],"search_zh":"地下式与地上式消火栓 / Underground and pillar hydrants 灭火设备与灭火剂实验室组 BU 范围 范围 PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016","test_object_zh":"地下式与地上式消火栓 / Underground and pillar hydrants"},{"_id":"6a7d78810636ba417e419cdd","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty podziemne i nadziemne / Underground and pillar hydrants","methodology":"Szczelność - Wytrzymałość na ciśnienie wewnętrzne - Wytrzymałość na różnicę ciśnień / Tightness - Resistance to internal pressure - Resistance to pressure difference","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność - Wytrzymałość na ciśnienie wewnętrzne - Wytrzymałość na różnicę ciśnień / Tightness - Resistance to internal pressure - Resistance to pressure difference","reference":"PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 1074-1:2002, Załącznik A (EN 1074-1:2000, Annex A) | PN-EN 1074-1:2002, Załącznik B (EN 1074-1:2000, Annex B)","norm_bases":["PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016","PN-EN 1074-1:2002, Załącznik A (EN 1074-1:2000, Annex A)","PN-EN 1074-1:2002, Załącznik B (EN 1074-1:2000, Annex B)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty podziemne i nadziemne / Underground and pillar hydrants Szczelność - Wytrzymałość na ciśnienie wewnętrzne - Wytrzymałość na różnicę ciśnień / Tightness - Resistance to internal pressure - Resistance to pressure difference PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 1074-1:2002, Załącznik A (EN 1074-1:2000, Annex A) | PN-EN 1074-1:2002, Załącznik B (EN 1074-1:2000, Annex B) Hydranty podziemne i nadziemne / Underground and pillar hydrants Szczelnosc - Wytrzymalosc na cisnienie wewnetrzne - Wytrzymalosc na roznice cisnien / Tightness - Resistance to internal pressure - Resistance to pressure difference PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 1074-1:2002, Zalacznik A (EN 1074-1:2000, Annex A) | PN-EN 1074-1:2002, Zalacznik B (EN 1074-1:2000, Annex B)","categories":["other"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Tightness - Resistance to internal pressure - Resistance to pressure difference","search_en":"Underground and pillar hydrants Tightness - Resistance to internal pressure - Resistance to pressure difference Fire Extinguishing Equipment and Agents Laboratories Group BU PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 1074-1:2002, Załącznik A (EN 1074-1:2000, Annex A) | PN-EN 1074-1:2002, Załącznik B (EN 1074-1:2000, Annex B)","test_object_en":"Underground and pillar hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"地下式与地上式消火栓 / Underground and pillar hydrants 灭火设备与灭火剂实验室组 BU PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 1074-1:2002, Załącznik A (EN 1074-1:2000, Annex A) | PN-EN 1074-1:2002, Załącznik B (EN 1074-1:2000, Annex B)","test_object_zh":"地下式与地上式消火栓 / Underground and pillar hydrants"},{"_id":"6a7d78810636ba417e419cde","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty podziemne i nadziemne / Underground and pillar hydrants","methodology":"Działanie - Czas trwania próby - Czas odwodnienia - Pozostałość wody w hydrancie / Operation - Duration of the trial - Drainage time - Residual water in a hydrant","parameters":[{"name":"Zakres","range":"Czas: do 9 h 59 min 59,99 s. Objętość: do 1000 ml"},{"name":"Scope","range":"Time: to 9 h 59 min 59,99 s Volume: to 1000 ml"}],"technique":null,"techniques":[],"computed":[],"activity":"Działanie - Czas trwania próby - Czas odwodnienia - Pozostałość wody w hydrancie / Operation - Duration of the trial - Drainage time - Residual water in a hydrant\nZakres:\nZakres Czas: do 9 h 59 min 59,99 s. Objętość: do 1000 ml\nScope Time: to 9 h 59 min 59,99 s Volume: to 1000 ml","reference":"PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.3 (EN 14339:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.6 (EN 1074-6:2008, p. 5.6)","norm_bases":["PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016","PN-EN 14339:2009, p. 5.3 (EN 14339:2005, p. 5.3)","PN-EN 1074-6:2009, p. 5.6 (EN 1074-6:2008, p. 5.6)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty podziemne i nadziemne / Underground and pillar hydrants Działanie - Czas trwania próby - Czas odwodnienia - Pozostałość wody w hydrancie / Operation - Duration of the trial - Drainage time - Residual water in a hydrant\nZakres:\nZakres Czas: do 9 h 59 min 59,99 s. Objętość: do 1000 ml\nScope Time: to 9 h 59 min 59,99 s Volume: to 1000 ml PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.3 (EN 14339:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.6 (EN 1074-6:2008, p. 5.6) Hydranty podziemne i nadziemne / Underground and pillar hydrants Dzialanie - Czas trwania proby - Czas odwodnienia - Pozostalosc wody w hydrancie / Operation - Duration of the trial - Drainage time - Residual water in a hydrant\nZakres:\nZakres Czas: do 9 h 59 min 59,99 s. Objetosc: do 1000 ml\nScope Time: to 9 h 59 min 59,99 s Volume: to 1000 ml PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.3 (EN 14339:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.6 (EN 1074-6:2008, p. 5.6)","categories":["water"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Operation - Duration of the trial - Drainage time - Residual water in a hydrant","parameters_en":[{"name":"Range","range":"Czas: do 9 h 59 min 59,99 s. Objętość: do 1000 ml"},{"name":"Scope","range":"Time: to 9 h 59 min 59,99 s Volume: to 1000 ml"}],"search_en":"Underground and pillar hydrants Operation - Duration of the trial - Drainage time - Residual water in a hydrant Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.3 (EN 14339:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.6 (EN 1074-6:2008, p. 5.6)","test_object_en":"Underground and pillar hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"Czas: do 9 h 59 min 59,99 s. Objętość: do 1000 ml"},{"name":"范围","range":"Time: to 9 h 59 min 59,99 s Volume: to 1000 ml"}],"search_zh":"地下式与地上式消火栓 / Underground and pillar hydrants 灭火设备与灭火剂实验室组 BU 范围 范围 PB/BU/321-322/1 edycja/edition 1 z/of 30.06.2016 | PN-EN 14339:2009, p. 5.3 (EN 14339:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.6 (EN 1074-6:2008, p. 5.6)","test_object_zh":"地下式与地上式消火栓 / Underground and pillar hydrants"},{"_id":"6a7d78810636ba417e419cdf","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty podziemne i nadziemne / Underground and pillar hydrants","methodology":"Współczynnik Kv / Kv factor","parameters":[{"name":"Zakres","range":"Natężenie przepływu wody: (137 - 4000) l/min Różnica ciśnień: do 130 kPa"},{"name":"Scope","range":"Water flow rate: (137- 4000) l/min Differential pressure: to 130 kPa"}],"technique":null,"techniques":[],"computed":[],"activity":"Współczynnik Kv / Kv factor\nZakres:\nZakres Natężenie przepływu wody: (137 - 4000) l/min Różnica ciśnień: do 130 kPa\nScope Water flow rate: (137- 4000) l/min Differential pressure: to 130 kPa","reference":"PN-EN 14384:2009, p. 5.3 (EN 14384:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.3 (EN 1074-6:2008, p. 5.3)","norm_bases":["PN-EN 14384:2009, p. 5.3 (EN 14384:2005, p. 5.3)","PN-EN 1074-6:2009, p. 5.3 (EN 1074-6:2008, p. 5.3)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty podziemne i nadziemne / Underground and pillar hydrants Współczynnik Kv / Kv factor\nZakres:\nZakres Natężenie przepływu wody: (137 - 4000) l/min Różnica ciśnień: do 130 kPa\nScope Water flow rate: (137- 4000) l/min Differential pressure: to 130 kPa PN-EN 14384:2009, p. 5.3 (EN 14384:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.3 (EN 1074-6:2008, p. 5.3) Hydranty podziemne i nadziemne / Underground and pillar hydrants Wspolczynnik Kv / Kv factor\nZakres:\nZakres Natezenie przeplywu wody: (137 - 4000) l/min Roznica cisnien: do 130 kPa\nScope Water flow rate: (137- 4000) l/min Differential pressure: to 130 kPa PN-EN 14384:2009, p. 5.3 (EN 14384:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.3 (EN 1074-6:2008, p. 5.3)","categories":["water"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Kv factor","parameters_en":[{"name":"Range","range":"Natężenie przepływu wody: (137 - 4000) l/min Różnica ciśnień: do 130 kPa"},{"name":"Scope","range":"Water flow rate: (137- 4000) l/min Differential pressure: to 130 kPa"}],"search_en":"Underground and pillar hydrants Kv factor Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 14384:2009, p. 5.3 (EN 14384:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.3 (EN 1074-6:2008, p. 5.3)","test_object_en":"Underground and pillar hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"Natężenie przepływu wody: (137 - 4000) l/min Różnica ciśnień: do 130 kPa"},{"name":"范围","range":"Water flow rate: (137- 4000) l/min Differential pressure: to 130 kPa"}],"search_zh":"地下式与地上式消火栓 / Underground and pillar hydrants 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 14384:2009, p. 5.3 (EN 14384:2005, p. 5.3) | PN-EN 1074-6:2009, p. 5.3 (EN 1074-6:2008, p. 5.3)","test_object_zh":"地下式与地上式消火栓 / Underground and pillar hydrants"},{"_id":"6a7d78810636ba417e419ce0","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty podziemne i nadziemne / Underground and pillar hydrants","methodology":"Wytrzymałość na obciążenie robocze / Workload resistance","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na obciążenie robocze / Workload resistance","reference":"PN-EN 1074-6:2009, Załącznik C (EN 1074-6:2008, Annex C) | PN-EN 1074-2:2002, Załącznik A (EN 1074-2:2000, Annex A)","norm_bases":["PN-EN 1074-6:2009, Załącznik C (EN 1074-6:2008, Annex C)","PN-EN 1074-2:2002, Załącznik A (EN 1074-2:2000, Annex A)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty podziemne i nadziemne / Underground and pillar hydrants Wytrzymałość na obciążenie robocze / Workload resistance PN-EN 1074-6:2009, Załącznik C (EN 1074-6:2008, Annex C) | PN-EN 1074-2:2002, Załącznik A (EN 1074-2:2000, Annex A) Hydranty podziemne i nadziemne / Underground and pillar hydrants Wytrzymalosc na obciazenie robocze / Workload resistance PN-EN 1074-6:2009, Zalacznik C (EN 1074-6:2008, Annex C) | PN-EN 1074-2:2002, Zalacznik A (EN 1074-2:2000, Annex A)","categories":["other"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Workload resistance","search_en":"Underground and pillar hydrants Workload resistance Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1074-6:2009, Załącznik C (EN 1074-6:2008, Annex C) | PN-EN 1074-2:2002, Załącznik A (EN 1074-2:2000, Annex A)","test_object_en":"Underground and pillar hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"地下式与地上式消火栓 / Underground and pillar hydrants 灭火设备与灭火剂实验室组 BU PN-EN 1074-6:2009, Załącznik C (EN 1074-6:2008, Annex C) | PN-EN 1074-2:2002, Załącznik A (EN 1074-2:2000, Annex A)","test_object_zh":"地下式与地上式消火栓 / Underground and pillar hydrants"},{"_id":"6a7d78810636ba417e419ce1","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty podziemne i nadziemne / Underground and pillar hydrants","methodology":"Trwałość / Durability","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość / Durability","reference":"PN-EN 1074-6:2009, p. 5.5.1 (EN 1074-6:2008, p. 5.5.1)","norm_bases":["PN-EN 1074-6:2009, p. 5.5.1 (EN 1074-6:2008, p. 5.5.1)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty podziemne i nadziemne / Underground and pillar hydrants Trwałość / Durability PN-EN 1074-6:2009, p. 5.5.1 (EN 1074-6:2008, p. 5.5.1) Hydranty podziemne i nadziemne / Underground and pillar hydrants Trwalosc / Durability PN-EN 1074-6:2009, p. 5.5.1 (EN 1074-6:2008, p. 5.5.1)","categories":["other"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Durability","search_en":"Underground and pillar hydrants Durability Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1074-6:2009, p. 5.5.1 (EN 1074-6:2008, p. 5.5.1)","test_object_en":"Underground and pillar hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"地下式与地上式消火栓 / Underground and pillar hydrants 灭火设备与灭火剂实验室组 BU PN-EN 1074-6:2009, p. 5.5.1 (EN 1074-6:2008, p. 5.5.1)","test_object_zh":"地下式与地上式消火栓 / Underground and pillar hydrants"},{"_id":"6a7d78810636ba417e419ce2","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty podziemne i nadziemne / Underground and pillar hydrants","methodology":"Odporność na środki dezynfekcyjne/ Resistance to disinfectants","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na środki dezynfekcyjne/ Resistance to disinfectants","reference":"PN-EN 1074-1:2002 zał. E (EN 1074-1:2000 Annex E)","norm_bases":["PN-EN 1074-1:2002 zał. E (EN 1074-1:2000 Annex E)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty podziemne i nadziemne / Underground and pillar hydrants Odporność na środki dezynfekcyjne/ Resistance to disinfectants PN-EN 1074-1:2002 zał. E (EN 1074-1:2000 Annex E) Hydranty podziemne i nadziemne / Underground and pillar hydrants Odpornosc na srodki dezynfekcyjne/ Resistance to disinfectants PN-EN 1074-1:2002 zal. E (EN 1074-1:2000 Annex E)","categories":["other"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to disinfectants","search_en":"Underground and pillar hydrants Resistance to disinfectants Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 1074-1:2002 zał. E (EN 1074-1:2000 Annex E)","test_object_en":"Underground and pillar hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"地下式与地上式消火栓 / Underground and pillar hydrants 灭火设备与灭火剂实验室组 BU PN-EN 1074-1:2002 zał. E (EN 1074-1:2000 Annex E)","test_object_zh":"地下式与地上式消火栓 / Underground and pillar hydrants"},{"_id":"6a7d78810636ba417e419ce3","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty nadziemne / Pillar hydrants","methodology":"Odporność na zginanie / Bending resistance","parameters":[{"name":"Zakres","range":"do 50 kN"},{"name":"Scope","range":"to 50 kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zginanie / Bending resistance\nZakres:\nZakres do 50 kN\nScope to 50 kN","reference":"PN-EN 1074-6:2009, p. 5.1.3 (EN 1074-6:2008, p. 5.1.3)","norm_bases":["PN-EN 1074-6:2009, p. 5.1.3 (EN 1074-6:2008, p. 5.1.3)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty nadziemne / Pillar hydrants Odporność na zginanie / Bending resistance\nZakres:\nZakres do 50 kN\nScope to 50 kN PN-EN 1074-6:2009, p. 5.1.3 (EN 1074-6:2008, p. 5.1.3) Hydranty nadziemne / Pillar hydrants Odpornosc na zginanie / Bending resistance\nZakres:\nZakres do 50 kN\nScope to 50 kN PN-EN 1074-6:2009, p. 5.1.3 (EN 1074-6:2008, p. 5.1.3)","categories":["other"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Bending resistance","parameters_en":[{"name":"Range","range":"do 50 kN"},{"name":"Scope","range":"to 50 kN"}],"search_en":"Pillar hydrants Bending resistance Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 1074-6:2009, p. 5.1.3 (EN 1074-6:2008, p. 5.1.3)","test_object_en":"Pillar hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"do 50 kN"},{"name":"范围","range":"to 50 kN"}],"search_zh":"灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 1074-6:2009, p. 5.1.3 (EN 1074-6:2008, p. 5.1.3)"},{"_id":"6a7d78810636ba417e419ce4","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Odporność na korozję zewnętrzną / Resistance to external corrosion","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na korozję zewnętrzną / Resistance to external corrosion","reference":"PN-EN 671-1:2012, załącznik B | PN-EN 671-2:2012, załącznik B (EN 671-1-2:2012, Annex B)","norm_bases":["PN-EN 671-1:2012, załącznik B","PN-EN 671-2:2012, załącznik B (EN 671-1-2:2012, Annex B)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Odporność na korozję zewnętrzną / Resistance to external corrosion PN-EN 671-1:2012, załącznik B | PN-EN 671-2:2012, załącznik B (EN 671-1-2:2012, Annex B) Hydranty wewnetrzne / Internal hydrants Odpornosc na korozje zewnetrzna / Resistance to external corrosion PN-EN 671-1:2012, zalacznik B | PN-EN 671-2:2012, zalacznik B (EN 671-1-2:2012, Annex B)","categories":["other"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to external corrosion / Resistance to external corrosion","search_en":"Internal hydrants Resistance to external corrosion / Resistance to external corrosion Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik B | PN-EN 671-2:2012, załącznik B (EN 671-1-2:2012, Annex B)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik B | PN-EN 671-2:2012, załącznik B (EN 671-1-2:2012, Annex B)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419ce5","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Odporność na korozję armatury wodnej / Resistance to corrosion of waterways","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na korozję armatury wodnej / Resistance to corrosion of waterways","reference":"PN-EN 671-1:2012, załącznik D | PN-EN 671-2:2012, załącznik D (PN-EN 671-1-2:2012, Annex D)","norm_bases":["PN-EN 671-1:2012, załącznik D","PN-EN 671-2:2012, załącznik D (PN-EN 671-1-2:2012, Annex D)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Odporność na korozję armatury wodnej / Resistance to corrosion of waterways PN-EN 671-1:2012, załącznik D | PN-EN 671-2:2012, załącznik D (PN-EN 671-1-2:2012, Annex D) Hydranty wewnetrzne / Internal hydrants Odpornosc na korozje armatury wodnej / Resistance to corrosion of waterways PN-EN 671-1:2012, zalacznik D | PN-EN 671-2:2012, zalacznik D (PN-EN 671-1-2:2012, Annex D)","categories":["water"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to corrosion of waterways","search_en":"Internal hydrants Resistance to corrosion of waterways Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik D | PN-EN 671-2:2012, załącznik D (PN-EN 671-1-2:2012, Annex D)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik D | PN-EN 671-2:2012, załącznik D (PN-EN 671-1-2:2012, Annex D)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419ce6","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Siła: - obracanie zwijadła - wyciągnięcia węża / Force: - to rotate the reel - to pull out the hose","parameters":[{"name":"Zakres","range":"(20 - 500) N"},{"name":"Scope","range":"(20 – 500) N"}],"technique":null,"techniques":[],"computed":[],"activity":"Siła: - obracanie zwijadła - wyciągnięcia węża / Force: - to rotate the reel - to pull out the hose\nZakres:\nZakres (20 - 500) N\nScope (20 – 500) N","reference":"PN-EN 671-1:2012, załącznik F.4 (EN 671-1:2012, Annex F.4)","norm_bases":["PN-EN 671-1:2012, załącznik F.4 (EN 671-1:2012, Annex F.4)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Siła: - obracanie zwijadła - wyciągnięcia węża / Force: - to rotate the reel - to pull out the hose\nZakres:\nZakres (20 - 500) N\nScope (20 – 500) N PN-EN 671-1:2012, załącznik F.4 (EN 671-1:2012, Annex F.4) Hydranty wewnetrzne / Internal hydrants Sila: - obracanie zwijadla - wyciagniecia weza / Force: - to rotate the reel - to pull out the hose\nZakres:\nZakres (20 - 500) N\nScope (20 – 500) N PN-EN 671-1:2012, zalacznik F.4 (EN 671-1:2012, Annex F.4)","categories":["other"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Force: - to rotate the reel - to pull out the hose","parameters_en":[{"name":"Range","range":"(20 - 500) N"},{"name":"Scope","range":"(20 – 500) N"}],"search_en":"Internal hydrants Force: - to rotate the reel - to pull out the hose Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 671-1:2012, załącznik F.4 (EN 671-1:2012, Annex F.4)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(20 - 500) N"},{"name":"范围","range":"(20 – 500) N"}],"search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 671-1:2012, załącznik F.4 (EN 671-1:2012, Annex F.4)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419ce7","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Wytrzymałość hydrantu na ciśnienie rozrywające / Resistance of a hydrant to burt pressure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość hydrantu na ciśnienie rozrywające / Resistance of a hydrant to burt pressure","reference":"PN-EN 671-1:2012, załącznik F.8 (EN 671-1:2012, Annex F.8)","norm_bases":["PN-EN 671-1:2012, załącznik F.8 (EN 671-1:2012, Annex F.8)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Wytrzymałość hydrantu na ciśnienie rozrywające / Resistance of a hydrant to burt pressure PN-EN 671-1:2012, załącznik F.8 (EN 671-1:2012, Annex F.8) Hydranty wewnetrzne / Internal hydrants Wytrzymalosc hydrantu na cisnienie rozrywajace / Resistance of a hydrant to burt pressure PN-EN 671-1:2012, zalacznik F.8 (EN 671-1:2012, Annex F.8)","categories":["other"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance of a hydrant to burt pressure","search_en":"Internal hydrants Resistance of a hydrant to burt pressure Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik F.8 (EN 671-1:2012, Annex F.8)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik F.8 (EN 671-1:2012, Annex F.8)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419ce8","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Moment obrotowy prądownicy / Torque of the nozzle","parameters":[{"name":"Zakres","range":"0,3 - 25 Nm"},{"name":"Scope","range":"0,3 - 25 Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Moment obrotowy prądownicy / Torque of the nozzle\nZakres:\nZakres 0,3 - 25 Nm\nScope 0,3 - 25 Nm","reference":"PN-EN 671-1:2012, załącznik E.2 | PN-EN 671-2:2012, załącznik E.2 (EN 671-1-2:2012, Annex E.2)","norm_bases":["PN-EN 671-1:2012, załącznik E.2","PN-EN 671-2:2012, załącznik E.2 (EN 671-1-2:2012, Annex E.2)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Moment obrotowy prądownicy / Torque of the nozzle\nZakres:\nZakres 0,3 - 25 Nm\nScope 0,3 - 25 Nm PN-EN 671-1:2012, załącznik E.2 | PN-EN 671-2:2012, załącznik E.2 (EN 671-1-2:2012, Annex E.2) Hydranty wewnetrzne / Internal hydrants Moment obrotowy pradownicy / Torque of the nozzle\nZakres:\nZakres 0,3 - 25 Nm\nScope 0,3 - 25 Nm PN-EN 671-1:2012, zalacznik E.2 | PN-EN 671-2:2012, zalacznik E.2 (EN 671-1-2:2012, Annex E.2)","categories":["other"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Torque of the nozzle","parameters_en":[{"name":"Range","range":"0,3 - 25 Nm"},{"name":"Scope","range":"0,3 - 25 Nm"}],"search_en":"Internal hydrants Torque of the nozzle Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 671-1:2012, załącznik E.2 | PN-EN 671-2:2012, załącznik E.2 (EN 671-1-2:2012, Annex E.2)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"0,3 - 25 Nm"},{"name":"范围","range":"0,3 - 25 Nm"}],"search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 671-1:2012, załącznik E.2 | PN-EN 671-2:2012, załącznik E.2 (EN 671-1-2:2012, Annex E.2)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419ce9","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Trwałość – próba stanowiskowa / Durability – bench test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość – próba stanowiskowa / Durability – bench test","reference":"PN-EN 671-1:2012, załącznik F.2 (EN 671-1:2012, Annex F.2)","norm_bases":["PN-EN 671-1:2012, załącznik F.2 (EN 671-1:2012, Annex F.2)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Trwałość – próba stanowiskowa / Durability – bench test PN-EN 671-1:2012, załącznik F.2 (EN 671-1:2012, Annex F.2) Hydranty wewnetrzne / Internal hydrants Trwalosc – proba stanowiskowa / Durability – bench test PN-EN 671-1:2012, zalacznik F.2 (EN 671-1:2012, Annex F.2)","categories":["other"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Durability – bench test","search_en":"Internal hydrants Durability – bench test Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik F.2 (EN 671-1:2012, Annex F.2)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik F.2 (EN 671-1:2012, Annex F.2)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419cea","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Odporność prądownicy na uderzenie / Impact resistance of the nozzle","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność prądownicy na uderzenie / Impact resistance of the nozzle","reference":"PN-EN 671-1:2012, załącznik E.1 | PN-EN 671-2:2012, załącznik E.1 (EN 671-1-2:2012, Annex E.1)","norm_bases":["PN-EN 671-1:2012, załącznik E.1","PN-EN 671-2:2012, załącznik E.1 (EN 671-1-2:2012, Annex E.1)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Odporność prądownicy na uderzenie / Impact resistance of the nozzle PN-EN 671-1:2012, załącznik E.1 | PN-EN 671-2:2012, załącznik E.1 (EN 671-1-2:2012, Annex E.1) Hydranty wewnetrzne / Internal hydrants Odpornosc pradownicy na uderzenie / Impact resistance of the nozzle PN-EN 671-1:2012, zalacznik E.1 | PN-EN 671-2:2012, zalacznik E.1 (EN 671-1-2:2012, Annex E.1)","categories":["other"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Impact resistance of the nozzle","search_en":"Internal hydrants Impact resistance of the nozzle Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik E.1 | PN-EN 671-2:2012, załącznik E.1 (EN 671-1-2:2012, Annex E.1)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik E.1 | PN-EN 671-2:2012, załącznik E.1 (EN 671-1-2:2012, Annex E.1)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419ceb","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Zasięg rzutu strumienia wody / Throw range of the water jet","parameters":[{"name":"Zakres","range":"(0,5 – 30) m"},{"name":"Scope","range":"(0,5 – 30) m"}],"technique":null,"techniques":[],"computed":[],"activity":"Zasięg rzutu strumienia wody / Throw range of the water jet\nZakres:\nZakres (0,5 – 30) m\nScope (0,5 – 30) m","reference":"PN-EN 671-1:2012, załącznik E.4.2 | PN-EN 671-2:2012, załącznik E.4.2 (EN 671-1-2:2012, Annex E.4.2)","norm_bases":["PN-EN 671-1:2012, załącznik E.4.2","PN-EN 671-2:2012, załącznik E.4.2 (EN 671-1-2:2012, Annex E.4.2)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Zasięg rzutu strumienia wody / Throw range of the water jet\nZakres:\nZakres (0,5 – 30) m\nScope (0,5 – 30) m PN-EN 671-1:2012, załącznik E.4.2 | PN-EN 671-2:2012, załącznik E.4.2 (EN 671-1-2:2012, Annex E.4.2) Hydranty wewnetrzne / Internal hydrants Zasieg rzutu strumienia wody / Throw range of the water jet\nZakres:\nZakres (0,5 – 30) m\nScope (0,5 – 30) m PN-EN 671-1:2012, zalacznik E.4.2 | PN-EN 671-2:2012, zalacznik E.4.2 (EN 671-1-2:2012, Annex E.4.2)","categories":["water"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Throw range of the water jet","parameters_en":[{"name":"Range","range":"(0,5 – 30) m"},{"name":"Scope","range":"(0,5 – 30) m"}],"search_en":"Internal hydrants Throw range of the water jet Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 671-1:2012, załącznik E.4.2 | PN-EN 671-2:2012, załącznik E.4.2 (EN 671-1-2:2012, Annex E.4.2)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0,5 – 30) m"},{"name":"范围","range":"(0,5 – 30) m"}],"search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 671-1:2012, załącznik E.4.2 | PN-EN 671-2:2012, załącznik E.4.2 (EN 671-1-2:2012, Annex E.4.2)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419cec","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Powierzchnia pokrycia prądem rozproszonym / Coverage area of the diffuse current","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Powierzchnia pokrycia prądem rozproszonym / Coverage area of the diffuse current","reference":"PN-EN 671-1:2012, załącznik E.3 | PN-EN 671-2:2012, załącznik E.3 (EN 671-1-2:2012, Annex E.3)","norm_bases":["PN-EN 671-1:2012, załącznik E.3","PN-EN 671-2:2012, załącznik E.3 (EN 671-1-2:2012, Annex E.3)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Powierzchnia pokrycia prądem rozproszonym / Coverage area of the diffuse current PN-EN 671-1:2012, załącznik E.3 | PN-EN 671-2:2012, załącznik E.3 (EN 671-1-2:2012, Annex E.3) Hydranty wewnetrzne / Internal hydrants Powierzchnia pokrycia pradem rozproszonym / Coverage area of the diffuse current PN-EN 671-1:2012, zalacznik E.3 | PN-EN 671-2:2012, zalacznik E.3 (EN 671-1-2:2012, Annex E.3)","categories":["other"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Coverage area of the diffuse current","search_en":"Internal hydrants Coverage area of the diffuse current Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik E.3 | PN-EN 671-2:2012, załącznik E.3 (EN 671-1-2:2012, Annex E.3)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik E.3 | PN-EN 671-2:2012, załącznik E.3 (EN 671-1-2:2012, Annex E.3)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419ced","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Natężenie przepływu wody prądu zwartego i rozproszonego / Water flow rate of dense and diffuse current","parameters":[{"name":"Zakres","range":"(10 - 500) l/min"},{"name":"Scope","range":"(10 – 500) l/min"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie przepływu wody prądu zwartego i rozproszonego / Water flow rate of dense and diffuse current\nZakres:\nZakres (10 - 500) l/min\nScope (10 – 500) l/min","reference":"PN-EN 671-1:2012, załącznik E.4.1 | PN-EN 671-2:2012, załącznik E.4.1 (EN 671-1-2:2012, Annex E.4.1)","norm_bases":["PN-EN 671-1:2012, załącznik E.4.1","PN-EN 671-2:2012, załącznik E.4.1 (EN 671-1-2:2012, Annex E.4.1)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Natężenie przepływu wody prądu zwartego i rozproszonego / Water flow rate of dense and diffuse current\nZakres:\nZakres (10 - 500) l/min\nScope (10 – 500) l/min PN-EN 671-1:2012, załącznik E.4.1 | PN-EN 671-2:2012, załącznik E.4.1 (EN 671-1-2:2012, Annex E.4.1) Hydranty wewnetrzne / Internal hydrants Natezenie przeplywu wody pradu zwartego i rozproszonego / Water flow rate of dense and diffuse current\nZakres:\nZakres (10 - 500) l/min\nScope (10 – 500) l/min PN-EN 671-1:2012, zalacznik E.4.1 | PN-EN 671-2:2012, zalacznik E.4.1 (EN 671-1-2:2012, Annex E.4.1)","categories":["water"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Water flow rate of the jet and spray stream / Water flow rate of dense and diffuse current","parameters_en":[{"name":"Range","range":"(10 - 500) l/min"},{"name":"Scope","range":"(10 – 500) l/min"}],"search_en":"Internal hydrants Water flow rate of the jet and spray stream / Water flow rate of dense and diffuse current Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 671-1:2012, załącznik E.4.1 | PN-EN 671-2:2012, załącznik E.4.1 (EN 671-1-2:2012, Annex E.4.1)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(10 - 500) l/min"},{"name":"范围","range":"(10 – 500) l/min"}],"search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 671-1:2012, załącznik E.4.1 | PN-EN 671-2:2012, załącznik E.4.1 (EN 671-1-2:2012, Annex E.4.1)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419cee","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Odporność na ciśnienie wewnętrzne / Resistance of internal pressure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na ciśnienie wewnętrzne / Resistance of internal pressure","reference":"PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)","norm_bases":["PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7)","PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Odporność na ciśnienie wewnętrzne / Resistance of internal pressure PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F) Hydranty wewnetrzne / Internal hydrants Odpornosc na cisnienie wewnetrzne / Resistance of internal pressure PN-EN 671-1:2012, zalacznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, zalacznik F (EN 671-2:2012, Annex F)","categories":["other"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance of internal pressure","search_en":"Internal hydrants Resistance of internal pressure Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419cef","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Odporność materiałów z tworzyw sztucznych na działanie światła i rozproszonego strumienia wody / Resistance of plastic materials to light and scattered water jets","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność materiałów z tworzyw sztucznych na działanie światła i rozproszonego strumienia wody / Resistance of plastic materials to light and scattered water jets","reference":"PN-EN 671-1:2012, załącznik C | PN-EN 671-2:2012, załącznik C (EN 671-1-2:2012, Annex C)","norm_bases":["PN-EN 671-1:2012, załącznik C","PN-EN 671-2:2012, załącznik C (EN 671-1-2:2012, Annex C)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Odporność materiałów z tworzyw sztucznych na działanie światła i rozproszonego strumienia wody / Resistance of plastic materials to light and scattered water jets PN-EN 671-1:2012, załącznik C | PN-EN 671-2:2012, załącznik C (EN 671-1-2:2012, Annex C) Hydranty wewnetrzne / Internal hydrants Odpornosc materialow z tworzyw sztucznych na dzialanie swiatla i rozproszonego strumienia wody / Resistance of plastic materials to light and scattered water jets PN-EN 671-1:2012, zalacznik C | PN-EN 671-2:2012, zalacznik C (EN 671-1-2:2012, Annex C)","categories":["materials","water"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance of plastic materials to light and scattered water jets","search_en":"Internal hydrants Resistance of plastic materials to light and scattered water jets Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik C | PN-EN 671-2:2012, załącznik C (EN 671-1-2:2012, Annex C)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik C | PN-EN 671-2:2012, załącznik C (EN 671-1-2:2012, Annex C)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419cf0","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Odporność na uderzenie i obciążenie zwijadła i łączników węża / Impact and load resistance of hose reels and fittings","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na uderzenie i obciążenie zwijadła i łączników węża / Impact and load resistance of hose reels and fittings","reference":"PN-EN 671-1:2012, załącznik F.6 (EN 671-1:2012, Annex F.6)","norm_bases":["PN-EN 671-1:2012, załącznik F.6 (EN 671-1:2012, Annex F.6)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Odporność na uderzenie i obciążenie zwijadła i łączników węża / Impact and load resistance of hose reels and fittings PN-EN 671-1:2012, załącznik F.6 (EN 671-1:2012, Annex F.6) Hydranty wewnetrzne / Internal hydrants Odpornosc na uderzenie i obciazenie zwijadla i lacznikow weza / Impact and load resistance of hose reels and fittings PN-EN 671-1:2012, zalacznik F.6 (EN 671-1:2012, Annex F.6)","categories":["other"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Impact and load resistance of hose reels and fittings","search_en":"Internal hydrants Impact and load resistance of hose reels and fittings Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik F.6 (EN 671-1:2012, Annex F.6)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik F.6 (EN 671-1:2012, Annex F.6)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419cf1","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Hydranty wewnętrzne / Internal hydrants","methodology":"Wymiary: - średnica zewnętrzna węża - średnica tarcz zwijadła - średnica bębna zwijadła - szerokość szczeliny bębna - długość węża / Dimensions - external diameter of the hose - diameter of the reel disc - diameter of the reel - width of the drum gap - hose length","parameters":[{"name":"Zakres","range":"(6 - 30000) mm"},{"name":"Scope","range":"(6 – 30000) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary: - średnica zewnętrzna węża - średnica tarcz zwijadła - średnica bębna zwijadła - szerokość szczeliny bębna - długość węża / Dimensions - external diameter of the hose - diameter of the reel disc - diameter of the reel - width of the drum gap - hose length\nZakres:\nZakres (6 - 30000) mm\nScope (6 – 30000) mm","reference":"PN-EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3 (EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3) | PN-EN 671-2:2012, p. 5.2.1, 5.4.1, 5.4.3 (EN 671-2:2012, p. 5.2.1, p. 5.4.1, p. 5.4.3)","norm_bases":["PN-EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3 (EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3)","PN-EN 671-2:2012, p. 5.2.1, 5.4.1, 5.4.3 (EN 671-2:2012, p. 5.2.1, p. 5.4.1, p. 5.4.3)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hydranty wewnętrzne / Internal hydrants Wymiary: - średnica zewnętrzna węża - średnica tarcz zwijadła - średnica bębna zwijadła - szerokość szczeliny bębna - długość węża / Dimensions - external diameter of the hose - diameter of the reel disc - diameter of the reel - width of the drum gap - hose length\nZakres:\nZakres (6 - 30000) mm\nScope (6 – 30000) mm PN-EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3 (EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3) | PN-EN 671-2:2012, p. 5.2.1, 5.4.1, 5.4.3 (EN 671-2:2012, p. 5.2.1, p. 5.4.1, p. 5.4.3) Hydranty wewnetrzne / Internal hydrants Wymiary: - srednica zewnetrzna weza - srednica tarcz zwijadla - srednica bebna zwijadla - szerokosc szczeliny bebna - dlugosc weza / Dimensions - external diameter of the hose - diameter of the reel disc - diameter of the reel - width of the drum gap - hose length\nZakres:\nZakres (6 - 30000) mm\nScope (6 – 30000) mm PN-EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3 (EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3) | PN-EN 671-2:2012, p. 5.2.1, 5.4.1, 5.4.3 (EN 671-2:2012, p. 5.2.1, p. 5.4.1, p. 5.4.3)","categories":["other"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Dimensions - external diameter of the hose - diameter of the reel disc - diameter of the reel - width of the drum gap - hose length","parameters_en":[{"name":"Range","range":"(6 - 30000) mm"},{"name":"Scope","range":"(6 – 30000) mm"}],"search_en":"Internal hydrants Dimensions - external diameter of the hose - diameter of the reel disc - diameter of the reel - width of the drum gap - hose length Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3 (EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3) | PN-EN 671-2:2012, p. 5.2.1, 5.4.1, 5.4.3 (EN 671-2:2012, p. 5.2.1, p. 5.4.1, p. 5.4.3)","test_object_en":"Internal hydrants","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(6 - 30000) mm"},{"name":"范围","range":"(6 – 30000) mm"}],"search_zh":"室内消火栓 / Internal hydrants 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3 (EN 671-1:2012, p. 5.2.1, 5.3.3, 5.4.3) | PN-EN 671-2:2012, p. 5.2.1, 5.4.1, 5.4.3 (EN 671-2:2012, p. 5.2.1, p. 5.4.1, p. 5.4.3)","test_object_zh":"室内消火栓 / Internal hydrants"},{"_id":"6a7d78810636ba417e419cf2","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Zawory hydrantowe / Hydrant valves","methodology":"Odporność na korozję kanałów wodnych / Corrosion resistance of water channels","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na korozję kanałów wodnych / Corrosion resistance of water channels","reference":"PN-EN 671-1:2012, załącznik D | PN-EN 671-2:2012, załącznik D (EN 671-1-2:2012, Annex D)","norm_bases":["PN-EN 671-1:2012, załącznik D","PN-EN 671-2:2012, załącznik D (EN 671-1-2:2012, Annex D)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zawory hydrantowe / Hydrant valves Odporność na korozję kanałów wodnych / Corrosion resistance of water channels PN-EN 671-1:2012, załącznik D | PN-EN 671-2:2012, załącznik D (EN 671-1-2:2012, Annex D) Zawory hydrantowe / Hydrant valves Odpornosc na korozje kanalow wodnych / Corrosion resistance of water channels PN-EN 671-1:2012, zalacznik D | PN-EN 671-2:2012, zalacznik D (EN 671-1-2:2012, Annex D)","categories":["water"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Corrosion resistance of water channels","search_en":"Hydrant valves Corrosion resistance of water channels Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik D | PN-EN 671-2:2012, załącznik D (EN 671-1-2:2012, Annex D)","test_object_en":"Hydrant valves","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"消火栓阀 / Hydrant valves 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik D | PN-EN 671-2:2012, załącznik D (EN 671-1-2:2012, Annex D)","test_object_zh":"消火栓阀 / Hydrant valves"},{"_id":"6a7d78810636ba417e419cf3","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Zawory hydrantowe / Hydrant valves","methodology":"Szczelność zamknięcia / Tightness of the closing","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność zamknięcia / Tightness of the closing","reference":"PN-EN 671-2:2012, p. 4.3.5 (EN 671-2:2012, p. 4.3.5)","norm_bases":["PN-EN 671-2:2012, p. 4.3.5 (EN 671-2:2012, p. 4.3.5)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zawory hydrantowe / Hydrant valves Szczelność zamknięcia / Tightness of the closing PN-EN 671-2:2012, p. 4.3.5 (EN 671-2:2012, p. 4.3.5) Zawory hydrantowe / Hydrant valves Szczelnosc zamkniecia / Tightness of the closing PN-EN 671-2:2012, p. 4.3.5 (EN 671-2:2012, p. 4.3.5)","categories":["other"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Tightness of the closing","search_en":"Hydrant valves Tightness of the closing Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-2:2012, p. 4.3.5 (EN 671-2:2012, p. 4.3.5)","test_object_en":"Hydrant valves","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"消火栓阀 / Hydrant valves 灭火设备与灭火剂实验室组 BU PN-EN 671-2:2012, p. 4.3.5 (EN 671-2:2012, p. 4.3.5)","test_object_zh":"消火栓阀 / Hydrant valves"},{"_id":"6a7d78810636ba417e419cf4","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Zawory hydrantowe / Hydrant valves","methodology":"Odporność na ciśnienie wewnętrzne / Resistance to internal pressure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na ciśnienie wewnętrzne / Resistance to internal pressure","reference":"PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)","norm_bases":["PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7)","PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zawory hydrantowe / Hydrant valves Odporność na ciśnienie wewnętrzne / Resistance to internal pressure PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F) Zawory hydrantowe / Hydrant valves Odpornosc na cisnienie wewnetrzne / Resistance to internal pressure PN-EN 671-1:2012, zalacznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, zalacznik F (EN 671-2:2012, Annex F)","categories":["other"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to internal pressure","search_en":"Hydrant valves Resistance to internal pressure Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)","test_object_en":"Hydrant valves","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"消火栓阀 / Hydrant valves 灭火设备与灭火剂实验室组 BU PN-EN 671-1:2012, załącznik F.7 (EN 671-1:2012, Annex F.7) | PN-EN 671-2:2012, załącznik F (EN 671-2:2012, Annex F)","test_object_zh":"消火栓阀 / Hydrant valves"},{"_id":"6a7d78810636ba417e419cf5","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Tryskacze / Sprinklers","methodology":"Rozpraszanie wody / Water scattering","parameters":[{"name":"Zakres","range":"(1 - 50) mm/min"},{"name":"Scope","range":"(1 – 50) mm/min"}],"technique":null,"techniques":[],"computed":[],"activity":"Rozpraszanie wody / Water scattering\nZakres:\nZakres (1 - 50) mm/min\nScope (1 – 50) mm/min","reference":"PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)","norm_bases":["PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tryskacze / Sprinklers Rozpraszanie wody / Water scattering\nZakres:\nZakres (1 - 50) mm/min\nScope (1 – 50) mm/min PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D) Tryskacze / Sprinklers Rozpraszanie wody / Water scattering\nZakres:\nZakres (1 - 50) mm/min\nScope (1 – 50) mm/min PN-EN 12259-1:2005+A3:2010 zal. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)","categories":["water"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Water scattering","parameters_en":[{"name":"Range","range":"(1 - 50) mm/min"},{"name":"Scope","range":"(1 – 50) mm/min"}],"search_en":"Sprinklers Water scattering Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)","test_object_en":"Sprinklers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(1 - 50) mm/min"},{"name":"范围","range":"(1 – 50) mm/min"}],"search_zh":"灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)"},{"_id":"6a7d78810636ba417e419cf6","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Zraszacze / Sprayers","methodology":"Geometria strumienia wodnego / Water stream geometry","parameters":[{"name":"Zakres","range":"(1 - 250) mm"},{"name":"Scope","range":"(1 – 250) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Geometria strumienia wodnego / Water stream geometry\nZakres:\nZakres (1 - 250) mm\nScope (1 – 250) mm","reference":"PB/BU/1601/1 edycja/edition 1 z/of 09.06.2016","norm_bases":["PB/BU/1601/1 edycja/edition 1 z/of 09.06.2016"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zraszacze / Sprayers Geometria strumienia wodnego / Water stream geometry\nZakres:\nZakres (1 - 250) mm\nScope (1 – 250) mm PB/BU/1601/1 edycja/edition 1 z/of 09.06.2016 Zraszacze / Sprayers Geometria strumienia wodnego / Water stream geometry\nZakres:\nZakres (1 - 250) mm\nScope (1 – 250) mm PB/BU/1601/1 edycja/edition 1 z/of 09.06.2016","categories":["water"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Water stream geometry","parameters_en":[{"name":"Range","range":"(1 - 250) mm"},{"name":"Scope","range":"(1 – 250) mm"}],"search_en":"Sprayers Water stream geometry Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PB/BU/1601/1 edycja/edition 1 z/of 09.06.2016","test_object_en":"Sprayers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(1 - 250) mm"},{"name":"范围","range":"(1 – 250) mm"}],"search_zh":"灭火设备与灭火剂实验室组 BU 范围 范围 PB/BU/1601/1 edycja/edition 1 z/of 09.06.2016"},{"_id":"6a7d78810636ba417e419cf7","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pompy / Pumps","methodology":"Szczelność także w miejscu wskazanym przez Zleceniodawcę / Tightness (Pump leakage test) also in place indicated by contractor","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność także w miejscu wskazanym przez Zleceniodawcę / Tightness (Pump leakage test) also in place indicated by contractor","reference":"PN-EN 12259-12:2024","norm_bases":["PN-EN 12259-12:2024"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pompy / Pumps Szczelność także w miejscu wskazanym przez Zleceniodawcę / Tightness (Pump leakage test) also in place indicated by contractor PN-EN 12259-12:2024 Pompy / Pumps Szczelnosc takze w miejscu wskazanym przez Zleceniodawce / Tightness (Pump leakage test) also in place indicated by contractor PN-EN 12259-12:2024","categories":["other"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Tightness (Pump leakage test) also in place indicated by contractor","search_en":"Pumps Tightness (Pump leakage test) also in place indicated by contractor Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 12259-12:2024","test_object_en":"Pumps","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泵 / Pumps 灭火设备与灭火剂实验室组 BU PN-EN 12259-12:2024","test_object_zh":"泵 / Pumps"},{"_id":"6a7d78810636ba417e419cf8","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pompy / Pumps","methodology":"Wytrzymałość korpusu także w miejscu wskazanym przez Zleceniodawcę / Pump casing strength also in place indicated by contractor","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość korpusu także w miejscu wskazanym przez Zleceniodawcę / Pump casing strength also in place indicated by contractor","reference":"PN-EN 12259-12:2024","norm_bases":["PN-EN 12259-12:2024"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pompy / Pumps Wytrzymałość korpusu także w miejscu wskazanym przez Zleceniodawcę / Pump casing strength also in place indicated by contractor PN-EN 12259-12:2024 Pompy / Pumps Wytrzymalosc korpusu takze w miejscu wskazanym przez Zleceniodawce / Pump casing strength also in place indicated by contractor PN-EN 12259-12:2024","categories":["other"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Pump casing strength also in place indicated by contractor","search_en":"Pumps Pump casing strength also in place indicated by contractor Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 12259-12:2024","test_object_en":"Pumps","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泵 / Pumps 灭火设备与灭火剂实验室组 BU PN-EN 12259-12:2024","test_object_zh":"泵 / Pumps"},{"_id":"6a7d78810636ba417e419cf9","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pompy / Pumps","methodology":"Prędkość obrotowa / Rotational speed","parameters":[{"name":"Zakres","range":"100 – 30 000 obrotów na minutę"},{"name":"Scope","range":"100 – 30 000 rpm"}],"technique":null,"techniques":[],"computed":[],"activity":"Prędkość obrotowa / Rotational speed\nZakres:\nZakres 100 – 30 000 obrotów na minutę\nScope 100 – 30 000 rpm","reference":"PN-EN 12259-12:2024","norm_bases":["PN-EN 12259-12:2024"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pompy / Pumps Prędkość obrotowa / Rotational speed\nZakres:\nZakres 100 – 30 000 obrotów na minutę\nScope 100 – 30 000 rpm PN-EN 12259-12:2024 Pompy / Pumps Predkosc obrotowa / Rotational speed\nZakres:\nZakres 100 – 30 000 obrotow na minute\nScope 100 – 30 000 rpm PN-EN 12259-12:2024","categories":["other"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Rotational speed","parameters_en":[{"name":"Range","range":"100 – 30 000 obrotów na minutę"},{"name":"Scope","range":"100 – 30 000 rpm"}],"search_en":"Pumps Rotational speed Fire Extinguishing Equipment and Agents Laboratories Group BU Range Scope PN-EN 12259-12:2024","test_object_en":"Pumps","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"100 – 30 000 obrotów na minutę"},{"name":"范围","range":"100 – 30 000 rpm"}],"search_zh":"泵 / Pumps 灭火设备与灭火剂实验室组 BU 范围 范围 PN-EN 12259-12:2024","test_object_zh":"泵 / Pumps"},{"_id":"6a7d78810636ba417e419cfa","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Zraszacze / Sprayers","methodology":"Rozpraszanie wody dla zraszaczy stojących lub wiszących / Water spray for upright or pendant sprinklers","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rozpraszanie wody dla zraszaczy stojących lub wiszących / Water spray for upright or pendant sprinklers","reference":"PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)","norm_bases":["PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zraszacze / Sprayers Rozpraszanie wody dla zraszaczy stojących lub wiszących / Water spray for upright or pendant sprinklers PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D) Zraszacze / Sprayers Rozpraszanie wody dla zraszaczy stojacych lub wiszacych / Water spray for upright or pendant sprinklers PN-EN 12259-1:2005+A3:2010 zal. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)","categories":["water"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Water spray for upright or pendant sprinklers","search_en":"Sprayers Water spray for upright or pendant sprinklers Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)","test_object_en":"Sprayers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU PN-EN 12259-1:2005+A3:2010 zał. D (EN 12259-1:1999+A1:2001/A3:2006, Annex D)"},{"_id":"6a7d78810636ba417e419cfb","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Generatory piany lekkiej / Foam generators","methodology":"Parametry piany Wydajność pianowa (z obliczeń)/ Foam parameters Foam efficiency (from calculation)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Parametry piany Wydajność pianowa (z obliczeń)/ Foam parameters Foam efficiency (from calculation)","reference":"PN-EN 13565-1:2019-09, zał. G (EN 13565-1:2019, Annex G)","norm_bases":["PN-EN 13565-1:2019-09, zał. G (EN 13565-1:2019, Annex G)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Generatory piany lekkiej / Foam generators Parametry piany Wydajność pianowa (z obliczeń)/ Foam parameters Foam efficiency (from calculation) PN-EN 13565-1:2019-09, zał. G (EN 13565-1:2019, Annex G) Generatory piany lekkiej / Foam generators Parametry piany Wydajnosc pianowa (z obliczen)/ Foam parameters Foam efficiency (from calculation) PN-EN 13565-1:2019-09, zal. G (EN 13565-1:2019, Annex G)","categories":["other"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Foam parameters Foam efficiency (from calculation)","search_en":"High expansion foam generators Foam parameters Foam efficiency (from calculation) Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 13565-1:2019-09, zał. G (EN 13565-1:2019, Annex G)","test_object_en":"High expansion foam generators","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU PN-EN 13565-1:2019-09, zał. G (EN 13565-1:2019, Annex G)"},{"_id":"6a7d78810636ba417e419cfc","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Wlewy piany, garnki pianowe / Foam poureres, foam chambers","methodology":"Przepływ maksymalny i ciśnienie wylotowe Sprawdzenie wypływu piany / Maximum flow and back pressure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepływ maksymalny i ciśnienie wylotowe Sprawdzenie wypływu piany / Maximum flow and back pressure","reference":"PN-EN 13565-1:2019 zał. J (EN 13565-1:2019 Annex J)","norm_bases":["PN-EN 13565-1:2019 zał. J (EN 13565-1:2019 Annex J)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wlewy piany, garnki pianowe / Foam poureres, foam chambers Przepływ maksymalny i ciśnienie wylotowe Sprawdzenie wypływu piany / Maximum flow and back pressure PN-EN 13565-1:2019 zał. J (EN 13565-1:2019 Annex J) Wlewy piany, garnki pianowe / Foam poureres, foam chambers Przeplyw maksymalny i cisnienie wylotowe Sprawdzenie wyplywu piany / Maximum flow and back pressure PN-EN 13565-1:2019 zal. J (EN 13565-1:2019 Annex J)","categories":["other"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Maximum flow and back pressure Check of foam discharge","search_en":"Foam poureres, foam chambers Maximum flow and back pressure Check of foam discharge Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 13565-1:2019 zał. J (EN 13565-1:2019 Annex J)","test_object_en":"Foam poureres, foam chambers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU PN-EN 13565-1:2019 zał. J (EN 13565-1:2019 Annex J)"},{"_id":"6a7d78810636ba417e419cfd","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Zraszacze pianowe / Foam sprayers","methodology":"Intensywność zraszania / Area coverage","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Intensywność zraszania / Area coverage","reference":"PN-EN 13565-1:2019 zał. I (EN 13565-1:2019 Annex I)","norm_bases":["PN-EN 13565-1:2019 zał. I (EN 13565-1:2019 Annex I)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zraszacze pianowe / Foam sprayers Intensywność zraszania / Area coverage PN-EN 13565-1:2019 zał. I (EN 13565-1:2019 Annex I) Zraszacze pianowe / Foam sprayers Intensywnosc zraszania / Area coverage PN-EN 13565-1:2019 zal. I (EN 13565-1:2019 Annex I)","categories":["other"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Area coverage","search_en":"Foam sprayers Area coverage Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 13565-1:2019 zał. I (EN 13565-1:2019 Annex I)","test_object_en":"Foam sprayers","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU PN-EN 13565-1:2019 zał. I (EN 13565-1:2019 Annex I)"},{"_id":"6a7d78810636ba417e419cfe","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Dysze mgłowe / Water-mist nozzle","methodology":"Odporność na korozję naprężeniową w chlorku magnezu / Stress corrosion cracking of stainless steel nozzle parts (magnesium chloride test)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na korozję naprężeniową w chlorku magnezu / Stress corrosion cracking of stainless steel nozzle parts (magnesium chloride test)","reference":"IMO Msc/Circ. 1165 z dn. 10.06.2005 ze zmianami: IMO Msc.1/Circ.1269 z 03.06.2008 | IMO Msc.1/Circ. 1386 z 10.12.2010","norm_bases":["IMO Msc/Circ. 1165 z dn. 10.06.2005 ze zmianami: IMO Msc.1/Circ.1269 z 03.06.2008","IMO Msc.1/Circ. 1386 z 10.12.2010"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dysze mgłowe / Water-mist nozzle Odporność na korozję naprężeniową w chlorku magnezu / Stress corrosion cracking of stainless steel nozzle parts (magnesium chloride test) IMO Msc/Circ. 1165 z dn. 10.06.2005 ze zmianami: IMO Msc.1/Circ.1269 z 03.06.2008 | IMO Msc.1/Circ. 1386 z 10.12.2010 Dysze mglowe / Water-mist nozzle Odpornosc na korozje naprezeniowa w chlorku magnezu / Stress corrosion cracking of stainless steel nozzle parts (magnesium chloride test) IMO Msc/Circ. 1165 z dn. 10.06.2005 ze zmianami: IMO Msc.1/Circ.1269 z 03.06.2008 | IMO Msc.1/Circ. 1386 z 10.12.2010","categories":["water","materials"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Stress corrosion cracking of stainless steel nozzle parts (magnesium chloride test)","search_en":"Water-mist nozzle Stress corrosion cracking of stainless steel nozzle parts (magnesium chloride test) Fire Extinguishing Equipment and Agents Laboratories Group BU IMO Msc/Circ. 1165 z dn. 10.06.2005 ze zmianami: IMO Msc.1/Circ.1269 z 03.06.2008 | IMO Msc.1/Circ. 1386 z 10.12.2010","test_object_en":"Water-mist nozzle","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"细水雾喷头 / Water-mist nozzle 灭火设备与灭火剂实验室组 BU IMO Msc/Circ. 1165 z dn. 10.06.2005 ze zmianami: IMO Msc.1/Circ.1269 z 03.06.2008 | IMO Msc.1/Circ. 1386 z 10.12.2010","test_object_zh":"细水雾喷头 / Water-mist nozzle"},{"_id":"6a7d78810636ba417e419cff","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Dysze mgłowe / Water-mist nozzle","methodology":"Odporność powłok na działanie temperatury / Coating resistance to temeratures Próba parowania / Evaporation test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność powłok na działanie temperatury / Coating resistance to temeratures Próba parowania / Evaporation test","reference":"IMO Msc/Circ 1165 z dn. 10.06.2005 r. Ze zmianami IMO MSC/Circ.1269 oraz IMO MSC.1/Circ. 1386","norm_bases":["IMO Msc/Circ 1165 z dn. 10.06.2005 r. Ze zmianami IMO MSC/Circ.1269 oraz IMO MSC.1/Circ. 1386"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dysze mgłowe / Water-mist nozzle Odporność powłok na działanie temperatury / Coating resistance to temeratures Próba parowania / Evaporation test IMO Msc/Circ 1165 z dn. 10.06.2005 r. Ze zmianami IMO MSC/Circ.1269 oraz IMO MSC.1/Circ. 1386 Dysze mglowe / Water-mist nozzle Odpornosc powlok na dzialanie temperatury / Coating resistance to temeratures Proba parowania / Evaporation test IMO Msc/Circ 1165 z dn. 10.06.2005 r. Ze zmianami IMO MSC/Circ.1269 oraz IMO MSC.1/Circ. 1386","categories":["water"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Coating resistance to temperatures Evaporation test","search_en":"Water-mist nozzle Coating resistance to temperatures Evaporation test Fire Extinguishing Equipment and Agents Laboratories Group BU IMO Msc/Circ 1165 z dn. 10.06.2005 r. Ze zmianami IMO MSC/Circ.1269 oraz IMO MSC.1/Circ. 1386","test_object_en":"Water-mist nozzle","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"细水雾喷头 / Water-mist nozzle 灭火设备与灭火剂实验室组 BU IMO Msc/Circ 1165 z dn. 10.06.2005 r. Ze zmianami IMO MSC/Circ.1269 oraz IMO MSC.1/Circ. 1386","test_object_zh":"细水雾喷头 / Water-mist nozzle"},{"_id":"6a7d78810636ba417e419d00","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Dysze mgłowe / Water-mist nozzle","methodology":"Dystrybucja wody / Water distribution","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Dystrybucja wody / Water distribution","reference":"PN-EN 17450-2:2025 zał. B (EN 17450-2:2025 Annex B)","norm_bases":["PN-EN 17450-2:2025 zał. B (EN 17450-2:2025 Annex B)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dysze mgłowe / Water-mist nozzle Dystrybucja wody / Water distribution PN-EN 17450-2:2025 zał. B (EN 17450-2:2025 Annex B) Dysze mglowe / Water-mist nozzle Dystrybucja wody / Water distribution PN-EN 17450-2:2025 zal. B (EN 17450-2:2025 Annex B)","categories":["water"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Water distribution","search_en":"Water-mist nozzle Water distribution Fire Extinguishing Equipment and Agents Laboratories Group BU PN-EN 17450-2:2025 zał. B (EN 17450-2:2025 Annex B)","test_object_en":"Water-mist nozzle","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"细水雾喷头 / Water-mist nozzle 灭火设备与灭火剂实验室组 BU PN-EN 17450-2:2025 zał. B (EN 17450-2:2025 Annex B)","test_object_zh":"细水雾喷头 / Water-mist nozzle"},{"_id":"6a7d78810636ba417e419d01","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Dysze mgłowe / Water-mist nozzle","methodology":"Wzajemne zraszanie / Lateral discharge","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wzajemne zraszanie / Lateral discharge","reference":"IMO Msc/Circ 1165 z dn. 10.06.2005 r. Wraz z rezolucją IMO A.800 (19) z dn. 23.11.1995 r.","norm_bases":["IMO Msc/Circ 1165 z dn. 10.06.2005 r. Wraz z rezolucją IMO A.800 (19) z dn. 23.11.1995 r."],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dysze mgłowe / Water-mist nozzle Wzajemne zraszanie / Lateral discharge IMO Msc/Circ 1165 z dn. 10.06.2005 r. Wraz z rezolucją IMO A.800 (19) z dn. 23.11.1995 r. Dysze mglowe / Water-mist nozzle Wzajemne zraszanie / Lateral discharge IMO Msc/Circ 1165 z dn. 10.06.2005 r. Wraz z rezolucja IMO A.800 (19) z dn. 23.11.1995 r.","categories":["water"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Lateral discharge","search_en":"Water-mist nozzle Lateral discharge Fire Extinguishing Equipment and Agents Laboratories Group BU IMO Msc/Circ 1165 z dn. 10.06.2005 r. Wraz z rezolucją IMO A.800 (19) z dn. 23.11.1995 r.","test_object_en":"Water-mist nozzle","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"细水雾喷头 / Water-mist nozzle 灭火设备与灭火剂实验室组 BU IMO Msc/Circ 1165 z dn. 10.06.2005 r. Wraz z rezolucją IMO A.800 (19) z dn. 23.11.1995 r.","test_object_zh":"细水雾喷头 / Water-mist nozzle"},{"_id":"6a7d78810636ba417e419d02","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings","methodology":"Próba odporności na cykliczne zmiany ciśnienia / Resistance to pressure cycling","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba odporności na cykliczne zmiany ciśnienia / Resistance to pressure cycling","reference":"EAD 100012-00-1106 (April 2020)","norm_bases":["EAD 100012-00-1106 (April 2020)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Próba odporności na cykliczne zmiany ciśnienia / Resistance to pressure cycling EAD 100012-00-1106 (April 2020) Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Proba odpornosci na cykliczne zmiany cisnienia / Resistance to pressure cycling EAD 100012-00-1106 (April 2020)","categories":["other"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to pressure cycling test","search_en":"Flexible sprinkler hose with end fittings Resistance to pressure cycling test Fire Extinguishing Equipment and Agents Laboratories Group BU EAD 100012-00-1106 (April 2020)","test_object_en":"Flexible sprinkler hose with end fittings","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings 灭火设备与灭火剂实验室组 BU EAD 100012-00-1106 (April 2020)","test_object_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings"},{"_id":"6a7d78810636ba417e419d03","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings","methodology":"Próba zmęczeniowa / Fatigue","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba zmęczeniowa / Fatigue","reference":"EAD 100012-00-1106 (April 2020)","norm_bases":["EAD 100012-00-1106 (April 2020)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Próba zmęczeniowa / Fatigue EAD 100012-00-1106 (April 2020) Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Proba zmeczeniowa / Fatigue EAD 100012-00-1106 (April 2020)","categories":["other"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Fatigue","search_en":"Flexible sprinkler hose with end fittings Fatigue Fire Extinguishing Equipment and Agents Laboratories Group BU EAD 100012-00-1106 (April 2020)","test_object_en":"Flexible sprinkler hose with end fittings","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings 灭火设备与灭火剂实验室组 BU EAD 100012-00-1106 (April 2020)","test_object_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings"},{"_id":"6a7d78810636ba417e419d04","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings","methodology":"Odporność na wibracje / Resistance to vibration","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wibracje / Resistance to vibration","reference":"EAD 100012-00-1106 (April 2020)","norm_bases":["EAD 100012-00-1106 (April 2020)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Odporność na wibracje / Resistance to vibration EAD 100012-00-1106 (April 2020) Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Odpornosc na wibracje / Resistance to vibration EAD 100012-00-1106 (April 2020)","categories":["other"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to vibration","search_en":"Flexible sprinkler hose with end fittings Resistance to vibration Fire Extinguishing Equipment and Agents Laboratories Group BU EAD 100012-00-1106 (April 2020)","test_object_en":"Flexible sprinkler hose with end fittings","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings 灭火设备与灭火剂实验室组 BU EAD 100012-00-1106 (April 2020)","test_object_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings"},{"_id":"6a7d78810636ba417e419d05","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings","methodology":"Próba próżniowa / Resistance to vaccum test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba próżniowa / Resistance to vaccum test","reference":"EAD 100012-00-1106 (April 2020)","norm_bases":["EAD 100012-00-1106 (April 2020)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Próba próżniowa / Resistance to vaccum test EAD 100012-00-1106 (April 2020) Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Proba prozniowa / Resistance to vaccum test EAD 100012-00-1106 (April 2020)","categories":["other"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to vaccum test","search_en":"Flexible sprinkler hose with end fittings Resistance to vaccum test Fire Extinguishing Equipment and Agents Laboratories Group BU EAD 100012-00-1106 (April 2020)","test_object_en":"Flexible sprinkler hose with end fittings","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings 灭火设备与灭火剂实验室组 BU EAD 100012-00-1106 (April 2020)","test_object_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings"},{"_id":"6a7d78810636ba417e419d06","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings","methodology":"Opór przepływu / Friction loss","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Opór przepływu / Friction loss","reference":"EAD 100012-00-1106 (April 2020)","norm_bases":["EAD 100012-00-1106 (April 2020)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Opór przepływu / Friction loss EAD 100012-00-1106 (April 2020) Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Opor przeplywu / Friction loss EAD 100012-00-1106 (April 2020)","categories":["other"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Friction loss","search_en":"Flexible sprinkler hose with end fittings Friction loss Fire Extinguishing Equipment and Agents Laboratories Group BU EAD 100012-00-1106 (April 2020)","test_object_en":"Flexible sprinkler hose with end fittings","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings 灭火设备与灭火剂实验室组 BU EAD 100012-00-1106 (April 2020)","test_object_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings"},{"_id":"6a7d78810636ba417e419d07","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings","methodology":"Wytrzymałość hydrostatyczna / Hydrostatic strength","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość hydrostatyczna / Hydrostatic strength","reference":"EAD 100012-00-1106 (April 2020)","norm_bases":["EAD 100012-00-1106 (April 2020)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Wytrzymałość hydrostatyczna / Hydrostatic strength EAD 100012-00-1106 (April 2020) Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Wytrzymalosc hydrostatyczna / Hydrostatic strength EAD 100012-00-1106 (April 2020)","categories":["other"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Hydrostatic strength","search_en":"Flexible sprinkler hose with end fittings Hydrostatic strength Fire Extinguishing Equipment and Agents Laboratories Group BU EAD 100012-00-1106 (April 2020)","test_object_en":"Flexible sprinkler hose with end fittings","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings 灭火设备与灭火剂实验室组 BU EAD 100012-00-1106 (April 2020)","test_object_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings"},{"_id":"6a7d78810636ba417e419d08","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings","methodology":"Wytrzymałość uszczelnienia / Seal inegrity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość uszczelnienia / Seal inegrity","reference":"EAD 100012-00-1106 (April 2020)","norm_bases":["EAD 100012-00-1106 (April 2020)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Wytrzymałość uszczelnienia / Seal inegrity EAD 100012-00-1106 (April 2020) Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Wytrzymalosc uszczelnienia / Seal inegrity EAD 100012-00-1106 (April 2020)","categories":["other"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Seal inegrity","search_en":"Flexible sprinkler hose with end fittings Seal inegrity Fire Extinguishing Equipment and Agents Laboratories Group BU EAD 100012-00-1106 (April 2020)","test_object_en":"Flexible sprinkler hose with end fittings","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings 灭火设备与灭火剂实验室组 BU EAD 100012-00-1106 (April 2020)","test_object_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings"},{"_id":"6a7d78810636ba417e419d09","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings","methodology":"Przepływ pod wysokim ciśnieniem / High pressure flow","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepływ pod wysokim ciśnieniem / High pressure flow","reference":"EAD 100012-00-1106 (April 2020)","norm_bases":["EAD 100012-00-1106 (April 2020)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Przepływ pod wysokim ciśnieniem / High pressure flow EAD 100012-00-1106 (April 2020) Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Przeplyw pod wysokim cisnieniem / High pressure flow EAD 100012-00-1106 (April 2020)","categories":["other"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"High pressure flow","search_en":"Flexible sprinkler hose with end fittings High pressure flow Fire Extinguishing Equipment and Agents Laboratories Group BU EAD 100012-00-1106 (April 2020)","test_object_en":"Flexible sprinkler hose with end fittings","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings 灭火设备与灭火剂实验室组 BU EAD 100012-00-1106 (April 2020)","test_object_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings"},{"_id":"6a7d78810636ba417e419d0a","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings","methodology":"Wydłużenie / Elongation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydłużenie / Elongation","reference":"EAD 100012-00-1106 (April 2020)","norm_bases":["EAD 100012-00-1106 (April 2020)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Wydłużenie / Elongation EAD 100012-00-1106 (April 2020) Elastyczne przewody tryskaczy / Flexible sprinkler hose with end fittings Wydluzenie / Elongation EAD 100012-00-1106 (April 2020)","categories":["other"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Elongation","search_en":"Flexible sprinkler hose with end fittings Elongation Fire Extinguishing Equipment and Agents Laboratories Group BU EAD 100012-00-1106 (April 2020)","test_object_en":"Flexible sprinkler hose with end fittings","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings 灭火设备与灭火剂实验室组 BU EAD 100012-00-1106 (April 2020)","test_object_zh":"带端接件的喷头软管 / Flexible sprinkler hose with end fittings"},{"_id":"6a7d78810636ba417e419d0b","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"SorbentyE / SorbentsE","methodology":"Skład ziarnowy / Grain composition Dry sieving method","parameters":[{"name":"Zakres","range":"sita 40 μm, 63 μm, 125 μm, 4 mm"},{"name":"Scope","range":"sieves 40 μm, 63 μm, 125 μm, 4 mm"}],"technique":"Metoda przesiewania na sucho","techniques":["Metoda przesiewania na sucho"],"computed":[],"activity":"Skład ziarnowy / Grain composition Dry sieving method\nZakres:\nZakres sita 40 μm, 63 μm, 125 μm, 4 mm\nScope sieves 40 μm, 63 μm, 125 μm, 4 mm\nMetoda przesiewania na sucho","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"SorbentyE / SorbentsE Skład ziarnowy / Grain composition Dry sieving method\nZakres:\nZakres sita 40 μm, 63 μm, 125 μm, 4 mm\nScope sieves 40 μm, 63 μm, 125 μm, 4 mm\nMetoda przesiewania na sucho Normy (Standards) SorbentyE / SorbentsE Sklad ziarnowy / Grain composition Dry sieving method\nZakres:\nZakres sita 40 μm, 63 μm, 125 μm, 4 mm\nScope sieves 40 μm, 63 μm, 125 μm, 4 mm\nMetoda przesiewania na sucho Normy (Standards)","categories":["food"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Grain composition Dry sieving method","parameters_en":[{"name":"Range","range":"sita 40 μm, 63 μm, 125 μm, 4 mm"},{"name":"Scope","range":"sieves 40 μm, 63 μm, 125 μm, 4 mm"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"SorbentsE Grain composition Dry sieving method Dry sieving method Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","technique_en":"Dry sieving method","test_object_en":"SorbentsE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"sita 40 μm, 63 μm, 125 μm, 4 mm"},{"name":"范围","range":"sieves 40 μm, 63 μm, 125 μm, 4 mm"}],"search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d0c","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"SorbentyE / SorbentsE","methodology":"Gęstość nasypowa / Bulk density","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość nasypowa / Bulk density","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"SorbentyE / SorbentsE Gęstość nasypowa / Bulk density Normy (Standards) SorbentyE / SorbentsE Gestosc nasypowa / Bulk density Normy (Standards)","categories":["other"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Bulk density","regulatory_area_en":"Flexible scope of accreditation","search_en":"SorbentsE Bulk density Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"SorbentsE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d0d","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Proszki gaśniczeE / Extinguishing powdersE","methodology":"Gęstość nasypowa / Bulk density","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość nasypowa / Bulk density","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Proszki gaśniczeE / Extinguishing powdersE Gęstość nasypowa / Bulk density Normy (Standards) Proszki gasniczeE / Extinguishing powdersE Gestosc nasypowa / Bulk density Normy (Standards)","categories":["other"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Bulk density","regulatory_area_en":"Flexible scope of accreditation","search_en":"Extinguishing powdersE Bulk density Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Extinguishing powdersE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d0e","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Proszki gaśniczeE / Extinguishing powdersE","methodology":"Skład ziarnowy na sitach 40 μm, 63 μm, 125 μm / Grain composition on sieves 40 μm, 63 μm, 125 μm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skład ziarnowy na sitach 40 μm, 63 μm, 125 μm / Grain composition on sieves 40 μm, 63 μm, 125 μm","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Proszki gaśniczeE / Extinguishing powdersE Skład ziarnowy na sitach 40 μm, 63 μm, 125 μm / Grain composition on sieves 40 μm, 63 μm, 125 μm Normy (Standards) Proszki gasniczeE / Extinguishing powdersE Sklad ziarnowy na sitach 40 μm, 63 μm, 125 μm / Grain composition on sieves 40 μm, 63 μm, 125 μm Normy (Standards)","categories":["food"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Grain composition on sieves 40 μm, 63 μm, 125 μm","regulatory_area_en":"Flexible scope of accreditation","search_en":"Extinguishing powdersE Grain composition on sieves 40 μm, 63 μm, 125 μm Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Extinguishing powdersE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d0f","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Farby i lakiery, Pianotwórcze środki gaśniczeE / Paints and varnishes, Foam concentrates E","methodology":"Gęstość metodą piknometryczną / Density by pycnometry method Weight method (pycnometer)","parameters":[{"name":"Zakres","range":"(0,7 – 1,6) g/cm3"},{"name":"Scope","range":"(0,7 – 1,6) g/cm3"}],"technique":"Metoda wagowa (piknometr)","techniques":["Metoda wagowa (piknometr)"],"computed":[],"activity":"Gęstość metodą piknometryczną / Density by pycnometry method Weight method (pycnometer)\nZakres:\nZakres (0,7 – 1,6) g/cm3\nScope (0,7 – 1,6) g/cm3\nMetoda wagowa (piknometr)","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Farby i lakiery, Pianotwórcze środki gaśniczeE / Paints and varnishes, Foam concentrates E Gęstość metodą piknometryczną / Density by pycnometry method Weight method (pycnometer)\nZakres:\nZakres (0,7 – 1,6) g/cm3\nScope (0,7 – 1,6) g/cm3\nMetoda wagowa (piknometr) Normy (Standards) Farby i lakiery, Pianotworcze srodki gasniczeE / Paints and varnishes, Foam concentrates E Gestosc metoda piknometryczna / Density by pycnometry method Weight method (pycnometer)\nZakres:\nZakres (0,7 – 1,6) g/cm3\nScope (0,7 – 1,6) g/cm3\nMetoda wagowa (piknometr) Normy (Standards)","categories":["automotive"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Density by pycnometry method Weight method (pycnometer)","parameters_en":[{"name":"Range","range":"(0,7 – 1,6) g/cm3"},{"name":"Scope","range":"(0,7 – 1,6) g/cm3"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Paints and varnishes, Foam concentrates E Density by pycnometry method Weight method (pycnometer) Gravimetric method (pycnometer) Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","technique_en":"Gravimetric method (pycnometer)","test_object_en":"Paints and varnishes, Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0,7 – 1,6) g/cm3"},{"name":"范围","range":"(0,7 – 1,6) g/cm3"}],"search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d10","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Gęstość metodą aerometryczną / Density by aerometric method","parameters":[{"name":"Zakres","range":"(0,900-1,300) g/cm3"},{"name":"Scope","range":"(0,900-1,300) g/cm3"}],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość metodą aerometryczną / Density by aerometric method\nZakres:\nZakres (0,900-1,300) g/cm3\nScope (0,900-1,300) g/cm3","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Gęstość metodą aerometryczną / Density by aerometric method\nZakres:\nZakres (0,900-1,300) g/cm3\nScope (0,900-1,300) g/cm3 Normy (Standards) Pianotworcze srodki gasnicze E / Foam concentrates E Gestosc metoda aerometryczna / Density by aerometric method\nZakres:\nZakres (0,900-1,300) g/cm3\nScope (0,900-1,300) g/cm3 Normy (Standards)","categories":["other"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Density by aerometric method","parameters_en":[{"name":"Range","range":"(0,900-1,300) g/cm3"},{"name":"Scope","range":"(0,900-1,300) g/cm3"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Density by aerometric method Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0,900-1,300) g/cm3"},{"name":"范围","range":"(0,900-1,300) g/cm3"}],"search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d11","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Lepkość / Viscosity Hoeppler method","parameters":[{"name":"Zakres","range":"(0,6-4 800) mPa·s"},{"name":"Scope","range":"(0,6-4 800) mPa·s"}],"technique":"Metoda Hoepplera","techniques":["Metoda Hoepplera"],"computed":[],"activity":"Lepkość / Viscosity Hoeppler method\nZakres:\nZakres (0,6-4 800) mPa·s\nScope (0,6-4 800) mPa·s\nMetoda Hoepplera","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Lepkość / Viscosity Hoeppler method\nZakres:\nZakres (0,6-4 800) mPa·s\nScope (0,6-4 800) mPa·s\nMetoda Hoepplera Normy (Standards) Pianotworcze srodki gasnicze E / Foam concentrates E Lepkosc / Viscosity Hoeppler method\nZakres:\nZakres (0,6-4 800) mPa·s\nScope (0,6-4 800) mPa·s\nMetoda Hoepplera Normy (Standards)","categories":["other"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Viscosity Hoeppler method","parameters_en":[{"name":"Range","range":"(0,6-4 800) mPa·s"},{"name":"Scope","range":"(0,6-4 800) mPa·s"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Viscosity Hoeppler method Hoeppler method Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","technique_en":"Hoeppler method","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0,6-4 800) mPa·s"},{"name":"范围","range":"(0,6-4 800) mPa·s"}],"search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d12","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Lepkość cieczy pseudoplastycznych Viscosity of pseudoplastic liquids Rotational method with coaxial cylinders","parameters":[{"name":"Zakres","range":"(4 – 4 000) mPa*s"},{"name":"Scope","range":"(4 – 4 000) mPa*s"}],"technique":"Metoda rotacyjna z cylindrami współosiowymi","techniques":["Metoda rotacyjna z cylindrami współosiowymi"],"computed":[],"activity":"Lepkość cieczy pseudoplastycznych Viscosity of pseudoplastic liquids Rotational method with coaxial cylinders\nZakres:\nZakres (4 – 4 000) mPa*s\nScope (4 – 4 000) mPa*s\nMetoda rotacyjna z cylindrami współosiowymi","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Lepkość cieczy pseudoplastycznych Viscosity of pseudoplastic liquids Rotational method with coaxial cylinders\nZakres:\nZakres (4 – 4 000) mPa*s\nScope (4 – 4 000) mPa*s\nMetoda rotacyjna z cylindrami współosiowymi Normy (Standards) Pianotworcze srodki gasnicze E / Foam concentrates E Lepkosc cieczy pseudoplastycznych Viscosity of pseudoplastic liquids Rotational method with coaxial cylinders\nZakres:\nZakres (4 – 4 000) mPa*s\nScope (4 – 4 000) mPa*s\nMetoda rotacyjna z cylindrami wspolosiowymi Normy (Standards)","categories":["other"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Viscosity of pseudoplastic liquids Rotational method with coaxial cylinders","parameters_en":[{"name":"Range","range":"(4 – 4 000) mPa*s"},{"name":"Scope","range":"(4 – 4 000) mPa*s"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Viscosity of pseudoplastic liquids Rotational method with coaxial cylinders Rotational method with coaxial cylinders Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","technique_en":"Rotational method with coaxial cylinders","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(4 – 4 000) mPa*s"},{"name":"范围","range":"(4 – 4 000) mPa*s"}],"search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d13","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"pH / pH Potentiometric method","parameters":[{"name":"Zakres","range":"1 - 14"},{"name":"Scope","range":"1 – 14"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH / pH Potentiometric method\nZakres:\nZakres 1 - 14\nScope 1 – 14\nMetoda potencjometryczna","reference":"PN-EN 1262 (EN 1262) | IMO MSC.1/Circ.1312","norm_bases":["PN-EN 1262 (EN 1262)","IMO MSC.1/Circ.1312"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E pH / pH Potentiometric method\nZakres:\nZakres 1 - 14\nScope 1 – 14\nMetoda potencjometryczna PN-EN 1262 (EN 1262) | IMO MSC.1/Circ.1312 Pianotworcze srodki gasnicze E / Foam concentrates E pH / pH Potentiometric method\nZakres:\nZakres 1 - 14\nScope 1 – 14\nMetoda potencjometryczna PN-EN 1262 (EN 1262) | IMO MSC.1/Circ.1312","categories":["other"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"pH Potentiometric method","parameters_en":[{"name":"Range","range":"1 - 14"},{"name":"Scope","range":"1 – 14"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E pH Potentiometric method Potentiometric method Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope PN-EN 1262 (EN 1262) | IMO MSC.1/Circ.1312","technique_en":"Potentiometric method","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"1 - 14"},{"name":"范围","range":"1 – 14"}],"search_zh":"泡沫灭火剂 E 电位法 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 PN-EN 1262 (EN 1262) | IMO MSC.1/Circ.1312","technique_zh":"电位法","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d14","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Napięcie powierzchniowe / Determination of surface tension Ring and plate method","parameters":[{"name":"Zakres","range":"(0 - 999,9) mN/m"},{"name":"Scope","range":"(0 – 999,9) mN/m"}],"technique":"Metoda pierścienia i płytki","techniques":["Metoda pierścienia i płytki"],"computed":[],"activity":"Napięcie powierzchniowe / Determination of surface tension Ring and plate method\nZakres:\nZakres (0 - 999,9) mN/m\nScope (0 – 999,9) mN/m\nMetoda pierścienia i płytki","reference":"PN-EN 14370 (EN 14370)","norm_bases":["PN-EN 14370 (EN 14370)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Napięcie powierzchniowe / Determination of surface tension Ring and plate method\nZakres:\nZakres (0 - 999,9) mN/m\nScope (0 – 999,9) mN/m\nMetoda pierścienia i płytki PN-EN 14370 (EN 14370) Pianotworcze srodki gasnicze E / Foam concentrates E Napiecie powierzchniowe / Determination of surface tension Ring and plate method\nZakres:\nZakres (0 - 999,9) mN/m\nScope (0 – 999,9) mN/m\nMetoda pierscienia i plytki PN-EN 14370 (EN 14370)","categories":["other"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Surface tension / Determination of surface tension Ring and plate method","parameters_en":[{"name":"Range","range":"(0 - 999,9) mN/m"},{"name":"Scope","range":"(0 – 999,9) mN/m"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Surface tension / Determination of surface tension Ring and plate method Ring and plate method Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope PN-EN 14370 (EN 14370)","technique_en":"Ring and plate method","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0 - 999,9) mN/m"},{"name":"范围","range":"(0 – 999,9) mN/m"}],"search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 PN-EN 14370 (EN 14370)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d15","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Współczynnik rozpływania / Dissipation coefficient","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Współczynnik rozpływania / Dissipation coefficient","reference":"IMO MSC.1/Circ.1312","norm_bases":["IMO MSC.1/Circ.1312"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Współczynnik rozpływania / Dissipation coefficient IMO MSC.1/Circ.1312 Pianotworcze srodki gasnicze E / Foam concentrates E Wspolczynnik rozplywania / Dissipation coefficient IMO MSC.1/Circ.1312","categories":["other"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Dissipation coefficient","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Dissipation coefficient Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation IMO MSC.1/Circ.1312","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 IMO MSC.1/Circ.1312","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d16","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Zawartość osadu / Sediment content Gravimetric method","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość osadu / Sediment content Gravimetric method\nMetoda wagowa","reference":"PB/BU/802/1","norm_bases":["PB/BU/802/1"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Zawartość osadu / Sediment content Gravimetric method\nMetoda wagowa PB/BU/802/1 Pianotworcze srodki gasnicze E / Foam concentrates E Zawartosc osadu / Sediment content Gravimetric method\nMetoda wagowa PB/BU/802/1","categories":["water"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Sediment content Gravimetric method","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Sediment content Gravimetric method Gravimetric method Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PB/BU/802/1","technique_en":"Gravimetric method","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 重量法 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PB/BU/802/1","technique_zh":"重量法","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d17","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Zawartości osadu / Sediment content Volumetric method","parameters":[],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawartości osadu / Sediment content Volumetric method\nMetoda objętościowa","reference":"PN-EN 1568-1 zał. C | PN-EN 1568-2 zał. C | PN-EN 1568-3 zał. C | PN-EN 1568-4 zał. C (EN 1568-1-4, Annex C) | IMO MSC.1/Circ.1312","norm_bases":["PN-EN 1568-1 zał. C","PN-EN 1568-2 zał. C","PN-EN 1568-3 zał. C","PN-EN 1568-4 zał. C (EN 1568-1-4, Annex C)","IMO MSC.1/Circ.1312"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Zawartości osadu / Sediment content Volumetric method\nMetoda objętościowa PN-EN 1568-1 zał. C | PN-EN 1568-2 zał. C | PN-EN 1568-3 zał. C | PN-EN 1568-4 zał. C (EN 1568-1-4, Annex C) | IMO MSC.1/Circ.1312 Pianotworcze srodki gasnicze E / Foam concentrates E Zawartosci osadu / Sediment content Volumetric method\nMetoda objetosciowa PN-EN 1568-1 zal. C | PN-EN 1568-2 zal. C | PN-EN 1568-3 zal. C | PN-EN 1568-4 zal. C (EN 1568-1-4, Annex C) | IMO MSC.1/Circ.1312","categories":["water"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Sediment content Volumetric method","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Sediment content Volumetric method Volumetric method Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PN-EN 1568-1 zał. C | PN-EN 1568-2 zał. C | PN-EN 1568-3 zał. C | PN-EN 1568-4 zał. C (EN 1568-1-4, Annex C) | IMO MSC.1/Circ.1312","technique_en":"Volumetric method","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 容量法 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PN-EN 1568-1 zał. C | PN-EN 1568-2 zał. C | PN-EN 1568-3 zał. C | PN-EN 1568-4 zał. C (EN 1568-1-4, Annex C) | IMO MSC.1/Circ.1312","regulatory_area_zh":"灵活的认可范围","technique_zh":"容量法","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d18","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Liczba spienienia / Expansion ratio","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Liczba spienienia / Expansion ratio","reference":"PN-78/C-83603/07 | PN-EN1568-1 zał. G | PN-EN 1568-2 zał. G | PN-EN 1568-3 zał. G | PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312","norm_bases":["PN-78/C-83603/07","PN-EN1568-1 zał. G","PN-EN 1568-2 zał. G","PN-EN 1568-3 zał. G","PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G)","IMO MSC.1/Circ.1312"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Liczba spienienia / Expansion ratio PN-78/C-83603/07 | PN-EN1568-1 zał. G | PN-EN 1568-2 zał. G | PN-EN 1568-3 zał. G | PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312 Pianotworcze srodki gasnicze E / Foam concentrates E Liczba spienienia / Expansion ratio PN-78/C-83603/07 | PN-EN1568-1 zal. G | PN-EN 1568-2 zal. G | PN-EN 1568-3 zal. G | PN-EN 1568-4 zal. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312","categories":["other"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Expansion ratio","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Expansion ratio Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PN-78/C-83603/07 | PN-EN1568-1 zał. G | PN-EN 1568-2 zał. G | PN-EN 1568-3 zał. G | PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PN-78/C-83603/07 | PN-EN1568-1 zał. G | PN-EN 1568-2 zał. G | PN-EN 1568-3 zał. G | PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d19","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Czas gaszenia / Extinction time","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas gaszenia / Extinction time","reference":"PB/BU/802/1","norm_bases":["PB/BU/802/1"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Czas gaszenia / Extinction time PB/BU/802/1 Pianotworcze srodki gasnicze E / Foam concentrates E Czas gaszenia / Extinction time PB/BU/802/1","categories":["other"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Extinction time","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Extinction time Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PB/BU/802/1","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PB/BU/802/1","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d1a","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Czas nawrotu palenia / Burn-back time","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas nawrotu palenia / Burn-back time","reference":"PB/BU/802/1","norm_bases":["PB/BU/802/1"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Czas nawrotu palenia / Burn-back time PB/BU/802/1 Pianotworcze srodki gasnicze E / Foam concentrates E Czas nawrotu palenia / Burn-back time PB/BU/802/1","categories":["other"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Burn-back time","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Burn-back time Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PB/BU/802/1","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PB/BU/802/1","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d1b","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Szybkość wykroplenia piany / Drainage time","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szybkość wykroplenia piany / Drainage time","reference":"PN-78/C-83603/05 | PN-EN1568-1 zał. G | PN-EN 1568-2 zał. G | PN-EN 1568-3 zał. G | PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312","norm_bases":["PN-78/C-83603/05","PN-EN1568-1 zał. G","PN-EN 1568-2 zał. G","PN-EN 1568-3 zał. G","PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G)","IMO MSC.1/Circ.1312"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Szybkość wykroplenia piany / Drainage time PN-78/C-83603/05 | PN-EN1568-1 zał. G | PN-EN 1568-2 zał. G | PN-EN 1568-3 zał. G | PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312 Pianotworcze srodki gasnicze E / Foam concentrates E Szybkosc wykroplenia piany / Drainage time PN-78/C-83603/05 | PN-EN1568-1 zal. G | PN-EN 1568-2 zal. G | PN-EN 1568-3 zal. G | PN-EN 1568-4 zal. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312","categories":["other"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Foam drainage time","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Foam drainage time Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PN-78/C-83603/05 | PN-EN1568-1 zał. G | PN-EN 1568-2 zał. G | PN-EN 1568-3 zał. G | PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PN-78/C-83603/05 | PN-EN1568-1 zał. G | PN-EN 1568-2 zał. G | PN-EN 1568-3 zał. G | PN-EN 1568-4 zał. G (EN 1568-1-4, Annex G) | IMO MSC.1/Circ.1312","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d1c","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Skuteczność gaśnicza / Extinguishing efficiency","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność gaśnicza / Extinguishing efficiency","reference":"PN-EN1568-1 zał. H | PN-EN 1568-2 zał. H | PN-EN 1568-3 zał. H | PN-EN 1568-4 zał. H (EN 1568-1-4, Annex H) | IMO MSC.1/Circ.1312 | ICAO Doc 9137- AN/898 Podręcznik służb portu lotniczego pkt. 8.1.8","norm_bases":["PN-EN1568-1 zał. H","PN-EN 1568-2 zał. H","PN-EN 1568-3 zał. H","PN-EN 1568-4 zał. H (EN 1568-1-4, Annex H)","IMO MSC.1/Circ.1312","ICAO Doc 9137- AN/898 Podręcznik służb portu lotniczego pkt. 8.1.8"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Skuteczność gaśnicza / Extinguishing efficiency PN-EN1568-1 zał. H | PN-EN 1568-2 zał. H | PN-EN 1568-3 zał. H | PN-EN 1568-4 zał. H (EN 1568-1-4, Annex H) | IMO MSC.1/Circ.1312 | ICAO Doc 9137- AN/898 Podręcznik służb portu lotniczego pkt. 8.1.8 Pianotworcze srodki gasnicze E / Foam concentrates E Skutecznosc gasnicza / Extinguishing efficiency PN-EN1568-1 zal. H | PN-EN 1568-2 zal. H | PN-EN 1568-3 zal. H | PN-EN 1568-4 zal. H (EN 1568-1-4, Annex H) | IMO MSC.1/Circ.1312 | ICAO Doc 9137- AN/898 Podrecznik sluzb portu lotniczego pkt. 8.1.8","categories":["other"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Extinguishing efficiency / Extinguishing efficiency","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Extinguishing efficiency / Extinguishing efficiency Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PN-EN1568-1 zał. H | PN-EN 1568-2 zał. H | PN-EN 1568-3 zał. H | PN-EN 1568-4 zał. H (EN 1568-1-4, Annex H) | IMO MSC.1/Circ.1312 | ICAO Doc 9137- AN/898 Podręcznik służb portu lotniczego pkt. 8.1.8","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PN-EN1568-1 zał. H | PN-EN 1568-2 zał. H | PN-EN 1568-3 zał. H | PN-EN 1568-4 zał. H (EN 1568-1-4, Annex H) | IMO MSC.1/Circ.1312 | ICAO Doc 9137- AN/898 Podręcznik służb portu lotniczego pkt. 8.1.8","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d1d","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Skuteczność gaśnicza w zakresie pożarów grupy A / Extinguishing efficiency – class A fire rating","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność gaśnicza w zakresie pożarów grupy A / Extinguishing efficiency – class A fire rating","reference":"PB/BU/802/1","norm_bases":["PB/BU/802/1"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Skuteczność gaśnicza w zakresie pożarów grupy A / Extinguishing efficiency – class A fire rating PB/BU/802/1 Pianotworcze srodki gasnicze E / Foam concentrates E Skutecznosc gasnicza w zakresie pozarow grupy A / Extinguishing efficiency – class A fire rating PB/BU/802/1","categories":["other"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Extinguishing efficiency – class A fire rating","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Extinguishing efficiency – class A fire rating Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PB/BU/802/1","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PB/BU/802/1","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d1e","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Skuteczność gaśnicza – testy w małej skali / Extinguishing efficiency – small scale fire tests","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność gaśnicza – testy w małej skali / Extinguishing efficiency – small scale fire tests","reference":"PN-EN 1568-3 zał. I | PN-EN 1568-4 zał. I (EN 1568-3-4, Annex I) | IMO MSC.1/Circ.1312","norm_bases":["PN-EN 1568-3 zał. I","PN-EN 1568-4 zał. I (EN 1568-3-4, Annex I)","IMO MSC.1/Circ.1312"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Skuteczność gaśnicza – testy w małej skali / Extinguishing efficiency – small scale fire tests PN-EN 1568-3 zał. I | PN-EN 1568-4 zał. I (EN 1568-3-4, Annex I) | IMO MSC.1/Circ.1312 Pianotworcze srodki gasnicze E / Foam concentrates E Skutecznosc gasnicza – testy w malej skali / Extinguishing efficiency – small scale fire tests PN-EN 1568-3 zal. I | PN-EN 1568-4 zal. I (EN 1568-3-4, Annex I) | IMO MSC.1/Circ.1312","categories":["other"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Extinguishing efficiency – small scale fire tests","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Extinguishing efficiency – small scale fire tests Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PN-EN 1568-3 zał. I | PN-EN 1568-4 zał. I (EN 1568-3-4, Annex I) | IMO MSC.1/Circ.1312","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PN-EN 1568-3 zał. I | PN-EN 1568-4 zał. I (EN 1568-3-4, Annex I) | IMO MSC.1/Circ.1312","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d1f","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Temperatura krzepnięcia / Freezing point","parameters":[{"name":"Zakres","range":"(-30 - +5)°C"},{"name":"Scope","range":"(-30 - +5)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura krzepnięcia / Freezing point\nZakres:\nZakres (-30 - +5)°C\nScope (-30 - +5)°C","reference":"PN-EN1568-1 zał. J (EN 1568-1, Annex J) | PN-EN 1568-2, zał. I | PN-EN 1568-3 zał. K | PN-EN 1568-4 zał. K (EN 1568-2-4, Annex K)","norm_bases":["PN-EN1568-1 zał. J (EN 1568-1, Annex J)","PN-EN 1568-2, zał. I","PN-EN 1568-3 zał. K","PN-EN 1568-4 zał. K (EN 1568-2-4, Annex K)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Temperatura krzepnięcia / Freezing point\nZakres:\nZakres (-30 - +5)°C\nScope (-30 - +5)°C PN-EN1568-1 zał. J (EN 1568-1, Annex J) | PN-EN 1568-2, zał. I | PN-EN 1568-3 zał. K | PN-EN 1568-4 zał. K (EN 1568-2-4, Annex K) Pianotworcze srodki gasnicze E / Foam concentrates E Temperatura krzepniecia / Freezing point\nZakres:\nZakres (-30 - +5)°C\nScope (-30 - +5)°C PN-EN1568-1 zal. J (EN 1568-1, Annex J) | PN-EN 1568-2, zal. I | PN-EN 1568-3 zal. K | PN-EN 1568-4 zal. K (EN 1568-2-4, Annex K)","categories":["other"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Freezing point","parameters_en":[{"name":"Range","range":"(-30 - +5)°C"},{"name":"Scope","range":"(-30 - +5)°C"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Freezing point Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope PN-EN1568-1 zał. J (EN 1568-1, Annex J) | PN-EN 1568-2, zał. I | PN-EN 1568-3 zał. K | PN-EN 1568-4 zał. K (EN 1568-2-4, Annex K)","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(-30 - +5)°C"},{"name":"范围","range":"(-30 - +5)°C"}],"search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 PN-EN1568-1 zał. J (EN 1568-1, Annex J) | PN-EN 1568-2, zał. I | PN-EN 1568-3 zał. K | PN-EN 1568-4 zał. K (EN 1568-2-4, Annex K)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d20","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Stabilność / rozwarstwianie się środka pianotwórczego Stability/ separation test of foam concentrate","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stabilność / rozwarstwianie się środka pianotwórczego Stability/ separation test of foam concentrate","reference":"PN-EN 1568-1 zał. K (EN 1568-1 Annex K) | PN-EN 1568-2 zał. J (PN-EN 1568-2 Annex J) | PN-EN 1568-3 zał. M (EN 1568-3 Annex M) | PN-EN 1568-4 zał. L (EN 1568-4 Annex L) | IMO MSC.1/Circ.1312","norm_bases":["PN-EN 1568-1 zał. K (EN 1568-1 Annex K)","PN-EN 1568-2 zał. J (PN-EN 1568-2 Annex J)","PN-EN 1568-3 zał. M (EN 1568-3 Annex M)","PN-EN 1568-4 zał. L (EN 1568-4 Annex L)","IMO MSC.1/Circ.1312"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Stabilność / rozwarstwianie się środka pianotwórczego Stability/ separation test of foam concentrate PN-EN 1568-1 zał. K (EN 1568-1 Annex K) | PN-EN 1568-2 zał. J (PN-EN 1568-2 Annex J) | PN-EN 1568-3 zał. M (EN 1568-3 Annex M) | PN-EN 1568-4 zał. L (EN 1568-4 Annex L) | IMO MSC.1/Circ.1312 Pianotworcze srodki gasnicze E / Foam concentrates E Stabilnosc / rozwarstwianie sie srodka pianotworczego Stability/ separation test of foam concentrate PN-EN 1568-1 zal. K (EN 1568-1 Annex K) | PN-EN 1568-2 zal. J (PN-EN 1568-2 Annex J) | PN-EN 1568-3 zal. M (EN 1568-3 Annex M) | PN-EN 1568-4 zal. L (EN 1568-4 Annex L) | IMO MSC.1/Circ.1312","categories":["other"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Stability/ separation test of foam concentrate","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Stability/ separation test of foam concentrate Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PN-EN 1568-1 zał. K (EN 1568-1 Annex K) | PN-EN 1568-2 zał. J (PN-EN 1568-2 Annex J) | PN-EN 1568-3 zał. M (EN 1568-3 Annex M) | PN-EN 1568-4 zał. L (EN 1568-4 Annex L) | IMO MSC.1/Circ.1312","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PN-EN 1568-1 zał. K (EN 1568-1 Annex K) | PN-EN 1568-2 zał. J (PN-EN 1568-2 Annex J) | PN-EN 1568-3 zał. M (EN 1568-3 Annex M) | PN-EN 1568-4 zał. L (EN 1568-4 Annex L) | IMO MSC.1/Circ.1312","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d21","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Pianotwórcze środki gaśnicze E / Foam concentrates E","methodology":"Tworzenie filmu wodnego/ Evaluation of film formation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Tworzenie filmu wodnego/ Evaluation of film formation","reference":"PN-EN 1568-3 zał. L (EN 1568-3 Annex L)","norm_bases":["PN-EN 1568-3 zał. L (EN 1568-3 Annex L)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Pianotwórcze środki gaśnicze E / Foam concentrates E Tworzenie filmu wodnego/ Evaluation of film formation PN-EN 1568-3 zał. L (EN 1568-3 Annex L) Pianotworcze srodki gasnicze E / Foam concentrates E Tworzenie filmu wodnego/ Evaluation of film formation PN-EN 1568-3 zal. L (EN 1568-3 Annex L)","categories":["other"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Evaluation of film formation","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam concentrates E Evaluation of film formation Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PN-EN 1568-3 zał. L (EN 1568-3 Annex L)","test_object_en":"Foam concentrates E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"泡沫灭火剂 E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 PN-EN 1568-3 zał. L (EN 1568-3 Annex L)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"泡沫灭火剂 E"},{"_id":"6a7d78810636ba417e419d22","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Garnki pianowe, generatory piany lekkiej, prądownice i wytwornice pianowe, działko wodno-pianowe, dozowniki środka pianotwórczegoE / Foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportionersE","methodology":"Wytrzymałość mechaniczna Odporność na ciśnienie hydrostatyczne / Mechanical strength Hydrostatic pressure test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość mechaniczna Odporność na ciśnienie hydrostatyczne / Mechanical strength Hydrostatic pressure test","reference":"Normy (Standards) | Procedury własne (Own procedures)","norm_bases":["Normy (Standards)","Procedury własne (Own procedures)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Garnki pianowe, generatory piany lekkiej, prądownice i wytwornice pianowe, działko wodno-pianowe, dozowniki środka pianotwórczegoE / Foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportionersE Wytrzymałość mechaniczna Odporność na ciśnienie hydrostatyczne / Mechanical strength Hydrostatic pressure test Normy (Standards) | Procedury własne (Own procedures) Garnki pianowe, generatory piany lekkiej, pradownice i wytwornice pianowe, dzialko wodno-pianowe, dozowniki srodka pianotworczegoE / Foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportionersE Wytrzymalosc mechaniczna Odpornosc na cisnienie hydrostatyczne / Mechanical strength Hydrostatic pressure test Normy (Standards) | Procedury wlasne (Own procedures)","categories":["water"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Mechanical strength Hydrostatic pressure test","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportionersE Mechanical strength Hydrostatic pressure test Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards) | Procedury własne (Own procedures)","test_object_en":"Foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportionersE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards) | Procedury własne (Own procedures)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d23","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Generator piany lekkiej, prądownice i wytwornice pianowe, zraszacze pianowe, dozownik środka pianotwórczego E/ Foam generators, branchpipes and foam generators, foam sprayers, foam proportionersE","methodology":"Natężenie przepływu Współczynnik wypływu K (z obliczeń) / Flow rate Discharge coefficient (from calculation)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie przepływu Współczynnik wypływu K (z obliczeń) / Flow rate Discharge coefficient (from calculation)","reference":"Normy (Standards) | Procedury własne (Own procedures)","norm_bases":["Normy (Standards)","Procedury własne (Own procedures)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Generator piany lekkiej, prądownice i wytwornice pianowe, zraszacze pianowe, dozownik środka pianotwórczego E/ Foam generators, branchpipes and foam generators, foam sprayers, foam proportionersE Natężenie przepływu Współczynnik wypływu K (z obliczeń) / Flow rate Discharge coefficient (from calculation) Normy (Standards) | Procedury własne (Own procedures) Generator piany lekkiej, pradownice i wytwornice pianowe, zraszacze pianowe, dozownik srodka pianotworczego E/ Foam generators, branchpipes and foam generators, foam sprayers, foam proportionersE Natezenie przeplywu Wspolczynnik wyplywu K (z obliczen) / Flow rate Discharge coefficient (from calculation) Normy (Standards) | Procedury wlasne (Own procedures)","categories":["other"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Flow rate Discharge coefficient K (calculated) / Flow rate Discharge coefficient (from calculation)","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam generators, branchpipes and foam generators, foam sprayers, foam proportionersE Flow rate Discharge coefficient K (calculated) / Flow rate Discharge coefficient (from calculation) Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards) | Procedury własne (Own procedures)","test_object_en":"Foam generators, branchpipes and foam generators, foam sprayers, foam proportionersE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards) | Procedury własne (Own procedures)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d24","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych Wodnych i Wodno-pianowych (tj. m.in. tryskacze, garnki pianowe, generatory piany lekkiej, prądownice i wytwornice pianowe, działka wodno-pianowe, dozowniki środka pianotwórczego)E / Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportioners)E","methodology":"Szczelność / Tightness","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność / Tightness","reference":"Normy (Standards) | Procedury własne (Own procedures)","norm_bases":["Normy (Standards)","Procedury własne (Own procedures)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych Wodnych i Wodno-pianowych (tj. m.in. tryskacze, garnki pianowe, generatory piany lekkiej, prądownice i wytwornice pianowe, działka wodno-pianowe, dozowniki środka pianotwórczego)E / Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportioners)E Szczelność / Tightness Normy (Standards) | Procedury własne (Own procedures) Podzespoly Stalych Urzadzen Gasniczych Wodnych i Wodno-pianowych (tj. m.in. tryskacze, garnki pianowe, generatory piany lekkiej, pradownice i wytwornice pianowe, dzialka wodno-pianowe, dozowniki srodka pianotworczego)E / Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportioners)E Szczelnosc / Tightness Normy (Standards) | Procedury wlasne (Own procedures)","categories":["water"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Tightness","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportioners)E Tightness Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards) | Procedury własne (Own procedures)","test_object_en":"Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, foam chambers, foam generators, branchpipes and foam generators, water-foam monitor, foam proportioners)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards) | Procedury własne (Own procedures)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d25","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych Wodnych i Wodno-pianowych (tj. m. in. Generatory piany lekkiej, wlewy piany, garnki pianowe, prądownice i wytwornice pianowe)E / Components of water and foam fixed extinguishing systems (i. e. foam generators, foam chambers, foam pourers, foam makers)E","methodology":"Odporność na działanie ciepła i ognia / Heat and fire resistance","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie ciepła i ognia / Heat and fire resistance","reference":"Normy Standards","norm_bases":["Normy Standards"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych Wodnych i Wodno-pianowych (tj. m. in. Generatory piany lekkiej, wlewy piany, garnki pianowe, prądownice i wytwornice pianowe)E / Components of water and foam fixed extinguishing systems (i. e. foam generators, foam chambers, foam pourers, foam makers)E Odporność na działanie ciepła i ognia / Heat and fire resistance Normy Standards Podzespoly Stalych Urzadzen Gasniczych Wodnych i Wodno-pianowych (tj. m. in. Generatory piany lekkiej, wlewy piany, garnki pianowe, pradownice i wytwornice pianowe)E / Components of water and foam fixed extinguishing systems (i. e. foam generators, foam chambers, foam pourers, foam makers)E Odpornosc na dzialanie ciepla i ognia / Heat and fire resistance Normy Standards","categories":["water"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Heat and fire resistance","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of water and foam fixed extinguishing systems (i. e. foam generators, foam chambers, foam pourers, foam makers)E Heat and fire resistance Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy Standards","test_object_en":"Components of water and foam fixed extinguishing systems (i. e. foam generators, foam chambers, foam pourers, foam makers)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy Standards","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d26","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych Wodnych i Wodno-pianowych (tj. m.in. tryskacze, zraszacze, zraszacze pianowe, garnki pianowe, prądownice i wytwornice pianowe, generatory piany lekkiej, działko wodno – pianowe, dozownik środka pianotwórczego)E / Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. Sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportioners)E","methodology":"Korozja w roztworze amoniaku / Stress corrosion in ammonia solution","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Korozja w roztworze amoniaku / Stress corrosion in ammonia solution","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych Wodnych i Wodno-pianowych (tj. m.in. tryskacze, zraszacze, zraszacze pianowe, garnki pianowe, prądownice i wytwornice pianowe, generatory piany lekkiej, działko wodno – pianowe, dozownik środka pianotwórczego)E / Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. Sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportioners)E Korozja w roztworze amoniaku / Stress corrosion in ammonia solution Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych Wodnych i Wodno-pianowych (tj. m.in. tryskacze, zraszacze, zraszacze pianowe, garnki pianowe, pradownice i wytwornice pianowe, generatory piany lekkiej, dzialko wodno – pianowe, dozownik srodka pianotworczego)E / Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. Sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportioners)E Korozja w roztworze amoniaku / Stress corrosion in ammonia solution Normy (Standards)","categories":["water"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Stress corrosion in ammonia solution","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. Sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportioners)E Stress corrosion in ammonia solution Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. Sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportioners)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d27","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E/ Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Korozja w roztworze dwutlenku siarki/ Corrosion in sulphur dioxide solution","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Korozja w roztworze dwutlenku siarki/ Corrosion in sulphur dioxide solution","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E/ Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Korozja w roztworze dwutlenku siarki/ Corrosion in sulphur dioxide solution Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E/ Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Korozja w roztworze dwutlenku siarki/ Corrosion in sulphur dioxide solution Normy (Standards)","categories":["other"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Corrosion in sulphur dioxide solution","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Corrosion in sulphur dioxide solution Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d28","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E/ Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Odporność na wibracje / resistance to vibration","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wibracje / resistance to vibration","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E/ Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odporność na wibracje / resistance to vibration Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E/ Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odpornosc na wibracje / resistance to vibration Normy (Standards)","categories":["other"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to vibration","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Resistance to vibration Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d29","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze) E) / Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles) E","methodology":"Działanie wilgotnego powietrza / Operation of humid air","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Działanie wilgotnego powietrza / Operation of humid air","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze) E) / Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles) E Działanie wilgotnego powietrza / Operation of humid air Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze) E) / Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles) E Dzialanie wilgotnego powietrza / Operation of humid air Normy (Standards)","categories":["other"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Operation of humid air","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles) E Operation of humid air Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extuinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles) E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d2a","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych Wodnych i Wodno-pianowych (tj. m.in. Tryskacze, zraszacze, zraszacze pianowe, garnki pianowe, prądownice i wytwornice pianowe, generatory piany lekkiej, działko wodno – pianowe) E / Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor) E","methodology":"Korozja w mgle solnej / Corrosion in salt spray","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Korozja w mgle solnej / Corrosion in salt spray","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych Wodnych i Wodno-pianowych (tj. m.in. Tryskacze, zraszacze, zraszacze pianowe, garnki pianowe, prądownice i wytwornice pianowe, generatory piany lekkiej, działko wodno – pianowe) E / Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor) E Korozja w mgle solnej / Corrosion in salt spray Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych Wodnych i Wodno-pianowych (tj. m.in. Tryskacze, zraszacze, zraszacze pianowe, garnki pianowe, pradownice i wytwornice pianowe, generatory piany lekkiej, dzialko wodno – pianowe) E / Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor) E Korozja w mgle solnej / Corrosion in salt spray Normy (Standards)","categories":["water"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Corrosion in salt spray","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor) E Corrosion in salt spray Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Water and Foam Fixed Firefighting Systems (i.e. i.a. sprinklers, sprayers, foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor) E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d2b","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Zraszacze pianowe, garnki pianowe, prądownice i wytwornice pianowe, generatory piany lekkiej, działko wodno – pianowe, dozownik środka pianotwórczegoE / Foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportionersE","methodology":"Korozja wewnętrzna / Internal corrosion","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Korozja wewnętrzna / Internal corrosion","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Zraszacze pianowe, garnki pianowe, prądownice i wytwornice pianowe, generatory piany lekkiej, działko wodno – pianowe, dozownik środka pianotwórczegoE / Foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportionersE Korozja wewnętrzna / Internal corrosion Normy (Standards) Zraszacze pianowe, garnki pianowe, pradownice i wytwornice pianowe, generatory piany lekkiej, dzialko wodno – pianowe, dozownik srodka pianotworczegoE / Foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportionersE Korozja wewnetrzna / Internal corrosion Normy (Standards)","categories":["water"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Internal corrosion","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportionersE Internal corrosion Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Foam sprayers, foam chambers, branchpipes and foam generators, foam generators, water-foam monitor, foam proportionersE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d2c","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Prądownice pianowe i wytwornice pianowe, działko wodno-pianowe, zraszacze pianoweE / Branchpipes and foam generators, water-foam monitor, foam sprayersE","methodology":"Parametry piany / Foam parameters","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Parametry piany / Foam parameters","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Prądownice pianowe i wytwornice pianowe, działko wodno-pianowe, zraszacze pianoweE / Branchpipes and foam generators, water-foam monitor, foam sprayersE Parametry piany / Foam parameters Normy (Standards) Pradownice pianowe i wytwornice pianowe, dzialko wodno-pianowe, zraszacze pianoweE / Branchpipes and foam generators, water-foam monitor, foam sprayersE Parametry piany / Foam parameters Normy (Standards)","categories":["water"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Foam parameters","regulatory_area_en":"Flexible scope of accreditation","search_en":"Branchpipes and foam generators, water-foam monitor, foam sprayersE Foam parameters Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Branchpipes and foam generators, water-foam monitor, foam sprayersE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d2d","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Działka wodno – pianoweE / Water-foam monitorE","methodology":"Natężenie przepływu Współczynnik wypływu K (z obliczeń)/ Flow rate Discharge coefficient (from calculation)","parameters":[{"name":"Zakres","range":"(17 – 9850) dm3/min"},{"name":"Scope","range":"(17 – 9850) dm3/min"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie przepływu Współczynnik wypływu K (z obliczeń)/ Flow rate Discharge coefficient (from calculation)\nZakres:\nZakres (17 – 9850) dm3/min\nScope (17 – 9850) dm3/min","reference":"PN-EN 13565-1 załącznik E (EN 13565-1, Annex E)","norm_bases":["PN-EN 13565-1 załącznik E (EN 13565-1, Annex E)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Działka wodno – pianoweE / Water-foam monitorE Natężenie przepływu Współczynnik wypływu K (z obliczeń)/ Flow rate Discharge coefficient (from calculation)\nZakres:\nZakres (17 – 9850) dm3/min\nScope (17 – 9850) dm3/min PN-EN 13565-1 załącznik E (EN 13565-1, Annex E) Dzialka wodno – pianoweE / Water-foam monitorE Natezenie przeplywu Wspolczynnik wyplywu K (z obliczen)/ Flow rate Discharge coefficient (from calculation)\nZakres:\nZakres (17 – 9850) dm3/min\nScope (17 – 9850) dm3/min PN-EN 13565-1 zalacznik E (EN 13565-1, Annex E)","categories":["water"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Flow rate Discharge coefficient K (calculated)/ Flow rate Discharge coefficient (from calculation)","parameters_en":[{"name":"Range","range":"(17 – 9850) dm3/min"},{"name":"Scope","range":"(17 – 9850) dm3/min"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Water-foam monitorE Flow rate Discharge coefficient K (calculated)/ Flow rate Discharge coefficient (from calculation) Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope PN-EN 13565-1 załącznik E (EN 13565-1, Annex E)","test_object_en":"Water-foam monitorE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(17 – 9850) dm3/min"},{"name":"范围","range":"(17 – 9850) dm3/min"}],"search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 PN-EN 13565-1 załącznik E (EN 13565-1, Annex E)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d2e","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Działka wodno – pianoweE / Water-foam monitorE","methodology":"Zasięg rzutu / Throw range","parameters":[{"name":"Zakres","range":"do 100 m"},{"name":"Scope","range":"to 100 m"}],"technique":null,"techniques":[],"computed":[],"activity":"Zasięg rzutu / Throw range\nZakres:\nZakres do 100 m\nScope to 100 m","reference":"PN-EN 13565-1 załącznik H (EN 13565-1, Annex H)","norm_bases":["PN-EN 13565-1 załącznik H (EN 13565-1, Annex H)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Działka wodno – pianoweE / Water-foam monitorE Zasięg rzutu / Throw range\nZakres:\nZakres do 100 m\nScope to 100 m PN-EN 13565-1 załącznik H (EN 13565-1, Annex H) Dzialka wodno – pianoweE / Water-foam monitorE Zasieg rzutu / Throw range\nZakres:\nZakres do 100 m\nScope to 100 m PN-EN 13565-1 zalacznik H (EN 13565-1, Annex H)","categories":["water"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Throw range","parameters_en":[{"name":"Range","range":"do 100 m"},{"name":"Scope","range":"to 100 m"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Water-foam monitorE Throw range Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope PN-EN 13565-1 załącznik H (EN 13565-1, Annex H)","test_object_en":"Water-foam monitorE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"do 100 m"},{"name":"范围","range":"to 100 m"}],"search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 PN-EN 13565-1 załącznik H (EN 13565-1, Annex H)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d2f","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Dozowniki środka pianotwórczegoE / Foam proportionersE","methodology":"Dokładność dozowania / Accuracy of proportioning","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Dokładność dozowania / Accuracy of proportioning","reference":"PN-EN 13565-1 (EN 13565-1)","norm_bases":["PN-EN 13565-1 (EN 13565-1)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Dozowniki środka pianotwórczegoE / Foam proportionersE Dokładność dozowania / Accuracy of proportioning PN-EN 13565-1 (EN 13565-1) Dozowniki srodka pianotworczegoE / Foam proportionersE Dokladnosc dozowania / Accuracy of proportioning PN-EN 13565-1 (EN 13565-1)","categories":["other"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Accuracy of proportioning","regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam proportionersE Accuracy of proportioning Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation PN-EN 13565-1 (EN 13565-1)","test_object_en":"Foam proportionersE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 PN-EN 13565-1 (EN 13565-1)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d30","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Garnki pianoweE / Foam chambersE","methodology":"Szczelność membrany / Vapour seal","parameters":[{"name":"Zakres","range":"(0,05 - 2) bar"},{"name":"Scope","range":"(0,05 - 2) bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność membrany / Vapour seal\nZakres:\nZakres (0,05 - 2) bar\nScope (0,05 - 2) bar","reference":"PN-EN 13565-1 (EN 13565-1)","norm_bases":["PN-EN 13565-1 (EN 13565-1)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Garnki pianoweE / Foam chambersE Szczelność membrany / Vapour seal\nZakres:\nZakres (0,05 - 2) bar\nScope (0,05 - 2) bar PN-EN 13565-1 (EN 13565-1) Garnki pianoweE / Foam chambersE Szczelnosc membrany / Vapour seal\nZakres:\nZakres (0,05 - 2) bar\nScope (0,05 - 2) bar PN-EN 13565-1 (EN 13565-1)","categories":["other"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Vapour seal","parameters_en":[{"name":"Range","range":"(0,05 - 2) bar"},{"name":"Scope","range":"(0,05 - 2) bar"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Foam chambersE Vapour seal Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope PN-EN 13565-1 (EN 13565-1)","test_object_en":"Foam chambersE","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0,05 - 2) bar"},{"name":"范围","range":"(0,05 - 2) bar"}],"search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 PN-EN 13565-1 (EN 13565-1)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d31","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Zraszacze, zraszacze pianowe, tryskacze E / Sprayers, foam sprayers, sprinklers E","methodology":"Odporność cieplna / Heat resistance","parameters":[{"name":"Zakres","range":"(20 - 1000) º C"},{"name":"Scope","range":"(20 - 1000) º C"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność cieplna / Heat resistance\nZakres:\nZakres (20 - 1000) º C\nScope (20 - 1000) º C","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Zraszacze, zraszacze pianowe, tryskacze E / Sprayers, foam sprayers, sprinklers E Odporność cieplna / Heat resistance\nZakres:\nZakres (20 - 1000) º C\nScope (20 - 1000) º C Normy (Standards) Zraszacze, zraszacze pianowe, tryskacze E / Sprayers, foam sprayers, sprinklers E Odpornosc cieplna / Heat resistance\nZakres:\nZakres (20 - 1000) º C\nScope (20 - 1000) º C Normy (Standards)","categories":["other"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Heat resistance","parameters_en":[{"name":"Range","range":"(20 - 1000) º C"},{"name":"Scope","range":"(20 - 1000) º C"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Sprayers, foam sprayers, sprinklers E Heat resistance Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","test_object_en":"Sprayers, foam sprayers, sprinklers E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(20 - 1000) º C"},{"name":"范围","range":"(20 - 1000) º C"}],"search_zh":"灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围"},{"_id":"6a7d78810636ba417e419d32","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Znamionowa temperatura otwarcia / Nominal opening temperaturę","parameters":[{"name":"Zakres","range":"(20 - 250) ºC"},{"name":"Scope","range":"(20 – 250) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Znamionowa temperatura otwarcia / Nominal opening temperaturę\nZakres:\nZakres (20 - 250) ºC\nScope (20 – 250) ºC","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Znamionowa temperatura otwarcia / Nominal opening temperaturę\nZakres:\nZakres (20 - 250) ºC\nScope (20 – 250) ºC Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Znamionowa temperatura otwarcia / Nominal opening temperature\nZakres:\nZakres (20 - 250) ºC\nScope (20 – 250) ºC Normy (Standards)","categories":["other"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Nominal opening temperaturę","parameters_en":[{"name":"Range","range":"(20 - 250) ºC"},{"name":"Scope","range":"(20 – 250) ºC"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Nominal opening temperaturę Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(20 - 250) ºC"},{"name":"范围","range":"(20 – 250) ºC"}],"search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d33","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Wytrzymałość korpusu tryskacza na rozciąganie / Tensile endurance of sprinkler body","parameters":[{"name":"Zakres","range":"(0,1 - 6) kN"},{"name":"Scope","range":"(0,1 – 6) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość korpusu tryskacza na rozciąganie / Tensile endurance of sprinkler body\nZakres:\nZakres (0,1 - 6) kN\nScope (0,1 – 6) kN","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Wytrzymałość korpusu tryskacza na rozciąganie / Tensile endurance of sprinkler body\nZakres:\nZakres (0,1 - 6) kN\nScope (0,1 – 6) kN Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Wytrzymalosc korpusu tryskacza na rozciaganie / Tensile endurance of sprinkler body\nZakres:\nZakres (0,1 - 6) kN\nScope (0,1 – 6) kN Normy (Standards)","categories":["other"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Tensile endurance of sprinkler body","parameters_en":[{"name":"Range","range":"(0,1 - 6) kN"},{"name":"Scope","range":"(0,1 – 6) kN"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Tensile endurance of sprinkler body Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0,1 - 6) kN"},{"name":"范围","range":"(0,1 – 6) kN"}],"search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d34","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Poprawność działania przy ciśnieniu od 0,1 bar do 100 bar / Correct operation at pressures from 0,1 bar to 100 bar","parameters":[{"name":"Zakres","range":"Temperatura: (380 - 420) ºC Czas: do 9 h 59 min 59,99 s Ciśnienie: do 100 bar"},{"name":"Scope","range":"Temperature: (380 – 420) ºC Time: to 9 h 59 min 59,99 s Pressure: to 100 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Poprawność działania przy ciśnieniu od 0,1 bar do 100 bar / Correct operation at pressures from 0,1 bar to 100 bar\nZakres:\nZakres Temperatura: (380 - 420) ºC Czas: do 9 h 59 min 59,99 s Ciśnienie: do 100 bar\nScope Temperature: (380 – 420) ºC Time: to 9 h 59 min 59,99 s Pressure: to 100 bar","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Poprawność działania przy ciśnieniu od 0,1 bar do 100 bar / Correct operation at pressures from 0,1 bar to 100 bar\nZakres:\nZakres Temperatura: (380 - 420) ºC Czas: do 9 h 59 min 59,99 s Ciśnienie: do 100 bar\nScope Temperature: (380 – 420) ºC Time: to 9 h 59 min 59,99 s Pressure: to 100 bar Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Poprawnosc dzialania przy cisnieniu od 0,1 bar do 100 bar / Correct operation at pressures from 0,1 bar to 100 bar\nZakres:\nZakres Temperatura: (380 - 420) ºC Czas: do 9 h 59 min 59,99 s Cisnienie: do 100 bar\nScope Temperature: (380 – 420) ºC Time: to 9 h 59 min 59,99 s Pressure: to 100 bar Normy (Standards)","categories":["other"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Correct operation at pressures from 0,1 bar to 100 bar","parameters_en":[{"name":"Range","range":"Temperatura: (380 - 420) ºC Czas: do 9 h 59 min 59,99 s Ciśnienie: do 100 bar"},{"name":"Scope","range":"Temperature: (380 – 420) ºC Time: to 9 h 59 min 59,99 s Pressure: to 100 bar"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Correct operation at pressures from 0,1 bar to 100 bar Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"Temperatura: (380 - 420) ºC Czas: do 9 h 59 min 59,99 s Ciśnienie: do 100 bar"},{"name":"范围","range":"Temperature: (380 – 420) ºC Time: to 9 h 59 min 59,99 s Pressure: to 100 bar"}],"search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d35","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Odporność na szok termiczny / Resistance to thermal shock","parameters":[{"name":"Zakres","range":"(5 - 200) ºC"},{"name":"Scope","range":"(5 – 200) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na szok termiczny / Resistance to thermal shock\nZakres:\nZakres (5 - 200) ºC\nScope (5 – 200) ºC","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odporność na szok termiczny / Resistance to thermal shock\nZakres:\nZakres (5 - 200) ºC\nScope (5 – 200) ºC Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odpornosc na szok termiczny / Resistance to thermal shock\nZakres:\nZakres (5 - 200) ºC\nScope (5 – 200) ºC Normy (Standards)","categories":["other"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to thermal shock","parameters_en":[{"name":"Range","range":"(5 - 200) ºC"},{"name":"Scope","range":"(5 – 200) ºC"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Resistance to thermal shock Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(5 - 200) ºC"},{"name":"范围","range":"(5 – 200) ºC"}],"search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d36","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Stała wypływu K od od 0,5 do 400 (l/min)/(bar)1/2/ Outflow constant K from 0,5 to 400 (l/min)/(bar)1/2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stała wypływu K od od 0,5 do 400 (l/min)/(bar)1/2/ Outflow constant K from 0,5 to 400 (l/min)/(bar)1/2","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Stała wypływu K od od 0,5 do 400 (l/min)/(bar)1/2/ Outflow constant K from 0,5 to 400 (l/min)/(bar)1/2 Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Stala wyplywu K od od 0,5 do 400 (l/min)/(bar)1/2/ Outflow constant K from 0,5 to 400 (l/min)/(bar)1/2 Normy (Standards)","categories":["other"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Outflow constant K from 0,5 to 400 (l/min)/(bar)1/2","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Outflow constant K from 0,5 to 400 (l/min)/(bar)1/2 Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d37","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Wymiary / Dimensions","parameters":[{"name":"Zakres","range":"(0,1 - 1000) mm"},{"name":"Scope","range":"(0,1 – 1000) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary / Dimensions\nZakres:\nZakres (0,1 - 1000) mm\nScope (0,1 – 1000) mm","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Wymiary / Dimensions\nZakres:\nZakres (0,1 - 1000) mm\nScope (0,1 – 1000) mm Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Wymiary / Dimensions\nZakres:\nZakres (0,1 - 1000) mm\nScope (0,1 – 1000) mm Normy (Standards)","categories":["other"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"(0,1 - 1000) mm"},{"name":"Scope","range":"(0,1 – 1000) mm"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Dimensions Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(0,1 - 1000) mm"},{"name":"范围","range":"(0,1 – 1000) mm"}],"search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 尺寸 / Dimensions 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E","methodology_zh":"尺寸 / Dimensions"},{"_id":"6a7d78810636ba417e419d38","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Wytrzymałość rozpryskiwacza i części mocujących tryskacza / Endurance of the sprinkler and sprinkler fixing parts","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość rozpryskiwacza i części mocujących tryskacza / Endurance of the sprinkler and sprinkler fixing parts","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Wytrzymałość rozpryskiwacza i części mocujących tryskacza / Endurance of the sprinkler and sprinkler fixing parts Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Wytrzymalosc rozpryskiwacza i czesci mocujacych tryskacza / Endurance of the sprinkler and sprinkler fixing parts Normy (Standards)","categories":["other"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Endurance of the sprinkler and sprinkler fixing parts","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Endurance of the sprinkler and sprinkler fixing parts Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d39","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Wytrzymałość elementu otwierającego / Endurance of the release element","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość elementu otwierającego / Endurance of the release element","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Wytrzymałość elementu otwierającego / Endurance of the release element Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Wytrzymalosc elementu otwierajacego / Endurance of the release element Normy (Standards)","categories":["other"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Endurance of the release element","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Endurance of the release element Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d3a","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Odporność na niskie temperatury / Resistance to low temperature","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na niskie temperatury / Resistance to low temperature","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odporność na niskie temperatury / Resistance to low temperature Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odpornosc na niskie temperatury / Resistance to low temperature Normy (Standards)","categories":["other"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to low temperature","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Resistance to low temperature Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d3b","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Odporność na uderzenie / Impact test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na uderzenie / Impact test","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odporność na uderzenie / Impact test Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odpornosc na uderzenie / Impact test Normy (Standards)","categories":["other"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Impact test","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Impact test Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d3c","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Działanie ciepła na tryskacze bez powłoki i z powłoką/ Heat exposure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Działanie ciepła na tryskacze bez powłoki i z powłoką/ Heat exposure","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Działanie ciepła na tryskacze bez powłoki i z powłoką/ Heat exposure Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Dzialanie ciepla na tryskacze bez powloki i z powloka/ Heat exposure Normy (Standards)","categories":["other"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Heat exposure of uncoated and coated sprinklers","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Heat exposure of uncoated and coated sprinklers Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d3d","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Rozdział wody poniżej rozpryskiwacza / Water distribution above amd below the deflector","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rozdział wody poniżej rozpryskiwacza / Water distribution above amd below the deflector","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Rozdział wody poniżej rozpryskiwacza / Water distribution above amd below the deflector Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Rozdzial wody ponizej rozpryskiwacza / Water distribution above amd below the deflector Normy (Standards)","categories":["water"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Water distribution above amd below the deflector","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Water distribution above amd below the deflector Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d3e","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Współczynnik C i RTI / C and RTI coefficient","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Współczynnik C i RTI / C and RTI coefficient","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Współczynnik C i RTI / C and RTI coefficient Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Wspolczynnik C i RTI / C and RTI coefficient Normy (Standards)","categories":["other"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"C and RTI coefficient","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E C and RTI coefficient Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d3f","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Odporność na działanie ciepła / Resistance to heat","parameters":[{"name":"Zakres","range":"(20-250)°C"},{"name":"Scope","range":"(20 – 250) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie ciepła / Resistance to heat\nZakres:\nZakres (20-250)°C\nScope (20 – 250) ºC","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odporność na działanie ciepła / Resistance to heat\nZakres:\nZakres (20-250)°C\nScope (20 – 250) ºC Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odpornosc na dzialanie ciepla / Resistance to heat\nZakres:\nZakres (20-250)°C\nScope (20 – 250) ºC Normy (Standards)","categories":["other"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to heat","parameters_en":[{"name":"Range","range":"(20-250)°C"},{"name":"Scope","range":"(20 – 250) ºC"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Resistance to heat Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(20-250)°C"},{"name":"范围","range":"(20 – 250) ºC"}],"search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d40","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Próba uderzenia wodnego / Water hammer test","parameters":[{"name":"Zakres","range":"(1-60) bar"},{"name":"Scope","range":"(1 -60) bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Próba uderzenia wodnego / Water hammer test\nZakres:\nZakres (1-60) bar\nScope (1 -60) bar","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Próba uderzenia wodnego / Water hammer test\nZakres:\nZakres (1-60) bar\nScope (1 -60) bar Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Proba uderzenia wodnego / Water hammer test\nZakres:\nZakres (1-60) bar\nScope (1 -60) bar Normy (Standards)","categories":["water"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Water hammer test","parameters_en":[{"name":"Range","range":"(1-60) bar"},{"name":"Scope","range":"(1 -60) bar"}],"regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Water hammer test Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Range Scope Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","parameters_zh":[{"name":"范围","range":"(1-60) bar"},{"name":"范围","range":"(1 -60) bar"}],"search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 范围 范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d41","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Odporność na niską temperaturę / Resistance to low temperatures","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na niską temperaturę / Resistance to low temperatures","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odporność na niską temperaturę / Resistance to low temperatures Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odpornosc na niska temperature / Resistance to low temperatures Normy (Standards)","categories":["other"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Resistance to low temperatures","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Resistance to low temperatures Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d42","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Szczelność metodą 30-dniową / 30-day leakage test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szczelność metodą 30-dniową / 30-day leakage test","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Szczelność metodą 30-dniową / 30-day leakage test Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Szczelnosc metoda 30-dniowa / 30-day leakage test Normy (Standards)","categories":["other"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"30-day leakage test","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E 30-day leakage test Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"},{"_id":"6a7d78810636ba417e419d43","lab_id":"69ad52a3de79e566650fb0f3","country":"PL","accr_number":"AB 060","accr_body":"PCA","test_object":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","methodology":"Odporność na podciśnienie / Vacuum test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na podciśnienie / Vacuum test","reference":"Normy (Standards)","norm_bases":["Normy (Standards)"],"lab_section":"Zespół Laboratoriów Urządzeń i Środków Gaśniczych BU","lab_address":null,"regulatory_area":"Zakres elastyczny akredytacji / Flexible scope of accreditation","flexible":false,"search_text":"Podzespoły Stałych Urządzeń Gaśniczych podające środek gaśniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odporność na podciśnienie / Vacuum test Normy (Standards) Podzespoly Stalych Urzadzen Gasniczych podajace srodek gasniczy (tj. m.in. tryskacze, zraszacze, dysze)E / Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Odpornosc na podcisnienie / Vacuum test Normy (Standards)","categories":["other"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Fire Extinguishing Equipment and Agents Laboratories Group BU","methodology_en":"Vacuum test","regulatory_area_en":"Flexible scope of accreditation","search_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E Vacuum test Fire Extinguishing Equipment and Agents Laboratories Group BU Flexible scope of accreditation Normy (Standards)","test_object_en":"Components of Fixed Firefighting Systems supplying the extinguishing agent (i.e. i.a. sprinklers, sprayers, nozzles)E","lab_section_zh":"灭火设备与灭火剂实验室组 BU","search_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E 灭火设备与灭火剂实验室组 BU 灵活的认可范围 Normy (Standards)","regulatory_area_zh":"灵活的认可范围","test_object_zh":"固定灭火系统中输送灭火剂的部件（即包括洒水喷头、喷淋头、喷嘴）E"}],"has_pdf":true}