🇨🇿 Wabtec Inspection Technologies Czech s.r.o. PL

ČIA 2371 • Praha 6, Czech Republic • 53 calibration items

Metrology & calibration

Wabtec Inspection Technologies Czech s.r.o. is a calibration laboratory accredited by ČIA under number 2371 (Praha 6, Czech Republic). Its accreditation scope covers 53 calibration items in the following areas: Metrology & calibration. Calibrated items include: Olympus/Evident Omniscan series ultrasonic flaw detectors, Olympus/Evident ultrasonic flaw detectors by automatic method, Olympus/Evident Nortec 500 series eddy current flaw detectors, Olympus/Evident BondMaster 600 series eddy current flaw detectors. Most frequently used calibration principles: Instrument display reading, Measurement with an oscilloscope, Calculation from measured values (ČSN EN 12668-1).

At a glance

  • Accreditation number: ČIA 2371
  • Calibration items in scope: 53
  • Types of calibrated items: 12
  • Calibration principles used: 38
  • City: Praha 6, Czech Republic
  • Valid until: 11-09-2030
Accreditation number
2371
Accreditation body
ČIA
Address
Evropská 16/176, Vokovice, 160 00 Praha 6
City
Praha 6, Czech Republic
Division
Laboratorium wzorcujące NDT
Valid until
11-09-2030

What this laboratory calibrates (12)

Calibration principles (38)

Certificate information

Certificate date
26.01.2026

Accreditation scope — calibration items (53)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Ultrasonic thickness gauges Calibration – length
0,150 mm to 5,100 mm · CMC 0,005 mm 5,100 mm to 100,00 mm · CMC 0,01 mm
CMC for the field of measured quantity: Length
Comparison with a length standard value DOC-23-00018
2 Magnamike thickness gauges Calibration – length
0,250 mm to 25,340 mm · CMC 0,005 mm
CMC for the field of measured quantity: Length
Comparison with a length standard value DOC-23-00018
3 Olympus/Evident ultrasonic thickness gauges by automatic method Calibration – testing of properties and defects of materials
Pulse repetition frequency — 3 Hz to 3 kHz · CMC 1 % Transmit pulse voltage — 2 V to 500 V · CMC 2 % Pulse tail — 2 V to 500 V · CMC 2 % Pulse rise time — 2 ns to 1200 ns · CMC 0,8 % Pulse duration — 2 ns to 1200 ns · CMC 0,8 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement with an oscilloscope (ČSN EN 15317) DOC-23-00018
4 Olympus/Evident ultrasonic thickness gauges by automatic method Calibration – testing of properties and defects of materials
Current operating range — 0,1 A to 2 A · CMC 1,5 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Power supply reading (ČSN EN 15317) DOC-23-00018
5 Olympus/Evident ultrasonic thickness gauges by automatic method Calibration – testing of properties and defects of materials
Precision and resolution — 0,25 mm to 100 mm · CMC 0,15 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Comparison with a length standard value (ČSN EN 15317) DOC-23-00018
6 Olympus/Evident ultrasonic flaw detectors by automatic method Calibration – testing of properties and defects of materials
Stability after heating, signal amplitude — 5 % SH to 100 % SH · CMC 0,14 % SH Stability after heating, signal position — 5 % SW to 100 % SW · CMC 0,12 % SW Display instability, signal amplitude — 5 % SH to 100 % SH · CMC 0,14 % SH Display instability, signal position — 5 % SW to 100 % SW · CMC 0,12 % SW Stability at voltage fluctuation, signal amplitude — 5 % SH to 100 % SH · CMC 0,14 % SH Stability at voltage fluctuation, signal position — 5 % SW to 100 % SW · CMC 0,12 % SW Transmit pulse voltage — 2 V to 500 V · CMC 3 % Pulse tail — 2 V to 500 V · CMC 3 % Pulse rise time — 2 ns to 1100 ns · CMC 2 % Pulse duration — 2 ns to 1100 ns · CMC 2 % Amplifier frequency response — 0,1 MHz to 26,5 MHz · CMC 2 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Instrument display reading (ČSN EN 12668-1) DOC-23-00019
7 Olympus/Evident ultrasonic flaw detectors by automatic method Calibration – testing of properties and defects of materials
Equivalent input noise level — 1 nV/√Hz to 80 nV/√Hz · CMC 7 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Calculation from measured values (ČSN EN 12668-1) DOC-23-00019
8 Olympus/Evident ultrasonic flaw detectors by automatic method Calibration – testing of properties and defects of materials
Calibrated attenuator accuracy — 0 dB to 110 dB · CMC 0,7 dB
CMC for the field of measured quantity: Testing of properties and defects of materials
Comparison with a reference attenuator (ČSN EN 12668-1) DOC-23-00019
9 Olympus/Evident ultrasonic flaw detectors by automatic method Calibration – testing of properties and defects of materials
Display unit vertical linearity — 5 % SH to 100 % SH · CMC 1 % SH Time base linearity — 5 % SW to 100 % SW · CMC 0,0004 % SW Time resolution — 50 ns to 150 ns · CMC 2 ns
CMC for the field of measured quantity: Testing of properties and defects of materials
Simulation by el. signal (ČSN EN 12668-1) DOC-23-00019
10 Olympus/Evident ultrasonic flaw detectors by automatic method Calibration – testing of properties and defects of materials
Transmit pulse voltage — 2 V to 500 V · CMC 3 % Pulse rise time — 2 ns to 1100 ns · CMC 2 % Pulse duration — 2 ns to 1100 ns · CMC 2 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement with an oscilloscope (ČSN EN ISO 22232-1) DOC-23-00019
11 Olympus/Evident ultrasonic flaw detectors by automatic method Calibration – testing of properties and defects of materials
Amplifier frequency response — 0,1 MHz to 26,5 MHz · CMC 2 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Instrument display reading (ČSN EN ISO 22232-1) DOC-23-00019
12 Olympus/Evident ultrasonic flaw detectors by automatic method Calibration – testing of properties and defects of materials
Equivalent input noise level — 1 nV/√Hz to 80 nV/√Hz · CMC 7 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Calculation from measured values (ČSN EN ISO 22232-1) DOC-23-00019
13 Olympus/Evident ultrasonic flaw detectors by automatic method Calibration – testing of properties and defects of materials
Calibrated attenuator accuracy — 0 dB to 110 dB · CMC 0,7 dB
CMC for the field of measured quantity: Testing of properties and defects of materials
Comparison with a reference standard (ČSN EN ISO 22232-1) DOC-23-00019
14 Olympus/Evident ultrasonic flaw detectors by automatic method Calibration – testing of properties and defects of materials
Display unit vertical linearity — 5 % SH to 100 % SH · CMC 1 % SH Time base linearity — 5 % SW to 100 % SW · CMC 0,0004 % SW
CMC for the field of measured quantity: Testing of properties and defects of materials
Simulation by el. signal (ČSN EN ISO 22232-1) DOC-23-00019
15 Olympus/Evident Nortec 500 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Instrument current demand — 550 mA to 850 mA · CMC 0,006 mA Instrument switching-off — 7,0 V to 8,0 V · CMC 0,06 V Instrument charging current — 1,0 A to 1,7 A · CMC 0,5 mA
CMC for the field of measured quantity: Testing of properties and defects of materials
Power supply reading DOC-23-00021
16 Olympus/Evident Nortec 500 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Output signal amplitude — 0,4 V to 4,2 V · CMC 0,05 mV Instrument driving pulse — 8,20 Vp-p to 10,27 Vp-p · CMC 0,06 Vp-p Instrument output frequency — 0 Hz to 100 Hz · CMC 0,1 Hz Instrument output frequency — 0 MHz to 12 MHz · CMC 12·10⁻⁶ MHz
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement by a multimeter DOC-23-00021
17 Olympus/Evident Nortec 500 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Filter test — 2 Hz to 8 Hz · CMC 0,057 Hz
CMC for the field of measured quantity: Testing of properties and defects of materials
Instrument display reading DOC-23-00021
18 Olympus/Evident Nortec 500 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Scanner output frequency, for 1200 RPM — 0 Hz to 20 Hz · CMC 0,02 Hz Scanner output frequency, for 3000 RPM — 0 Hz to 50 Hz · CMC 0,05 Hz Additional outputs Frequency No. 1 & No. 2 — 5 V · CMC 0,06 V
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement with an oscilloscope DOC-23-00021
19 Olympus/Evident Nortec 500 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Instrument conductivity — 30 % IACS to 60 % IACS · CMC 0,17 % IACS
CMC for the field of measured quantity: Testing of properties and defects of materials
Comparison with a reference standard DOC-23-00021
20 Olympus/Evident Nortec 600 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Excitation frequency — 10·10⁻⁶ MHz to 10 MHz · CMC 2 % Harmonic distortion — 10·10⁻⁶ MHz to 10 MHz · CMC 0,3 % Maximum output voltage — 1,8 Vp-p to 2,2 Vp-p · CMC 0,3 % Maximum permissible input voltage — 0,1 Vp-p to 14,4 Vp-p · CMC 0,5 % Signal processing frequency response — 0,1 kHz to 2 kHz · CMC 0,1 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement with an oscilloscope (ČSN EN ISO 15548-1) DOC-23-00021
21 Olympus/Evident Nortec 600 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Phase linearity — 0° to 360° · CMC 0,002°
CMC for the field of measured quantity: Testing of properties and defects of materials
Instrument display reading (ČSN EN ISO 15548-1) DOC-23-00021
22 Olympus/Evident Nortec 600 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Gain setting accuracy — 0 dB to 100 dB · CMC 0,07 dB
CMC for the field of measured quantity: Testing of properties and defects of materials
Comparison with a reference attenuator (ČSN EN ISO 15548-1) DOC-23-00021
23 Olympus/Evident Nortec 600 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Instrument maximum noise — 1,8 µV to 15,0 µV · CMC 0,5 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Calculation from measured values (ČSN EN ISO 15548-1) DOC-23-00021
24 Olympus/Evident BondMaster 600 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Excitation frequency — 1 kHz to 500 kHz · CMC 2 % Harmonic distortion — 10·10⁻⁶ MHz to 10 MHz · CMC 0,3 % Maximum output voltage of TX generator (MIA, RESONANCE) and HV generator (MIA) — 0,9 Vp-p to 140 Vp-p · CMC 0,3 % Input voltage linearity — 0,01 % to 0,75 % · CMC 0,5 % Signal processing frequency response — 70 Hz to 80 Hz · CMC 0,1 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement with an oscilloscope DOC-23-00021
25 Olympus/Evident BondMaster 600 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Phase linearity — 0° to 360° · CMC 0,002°
CMC for the field of measured quantity: Testing of properties and defects of materials
Instrument display reading DOC-23-00021
26 Olympus/Evident BondMaster 600 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Gain setting accuracy — 0 dB to 100 dB · CMC 0,07 dB
CMC for the field of measured quantity: Testing of properties and defects of materials
Comparison with a reference attenuator DOC-23-00021
27 Olympus/Evident BondMaster 600 series eddy current flaw detectors Calibration – testing of properties and defects of materials
Instrument maximum noise — 1,8 µV to 15 µV · CMC 0,5 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Calculation from measured values DOC-23-00021
28 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Stability after heating (mm), signal amplitude — 5 % SH to 100 % SH · CMC 0,14 % SH Stability after heating (mm), signal position — 5 % SW to 100 % SW · CMC 0,12 % SW Display unit instability, signal amplitude (mm) — 5 % SH to 100 % SH · CMC 0,14 % SH Display unit instability, signal position (mm) — 5 % SW to 100 % SW · CMC 0,12 % SW Stability at voltage variations, signal amplitude (mm) — 5 % SH to 100 % SH · CMC 0,14 % SH Stability at voltage variations, signal position (mm) — 5 % SW to 100 % SW · CMC 0,12 % SW
CMC for the field of measured quantity: Testing of properties and defects of materials
Instrument display signal reading (ČSN EN 12668-1) DOC-23-00022
29 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Transmit pulse voltage — 2 V to 500 V · CMC 3 % Pulse tail — 2 V to 500 V · CMC 3 % Pulse rise time — 2 ns to 1100 ns · CMC 2 % Pulse duration — 2 ns to 1100 ns · CMC 2 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement with an oscilloscope (ČSN EN 12668-1) DOC-23-00022
30 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Amplifier frequency response — 0,1 MHz to 26,5 MHz · CMC 2 % Display unit vertical linearity (mm) — 5 % SH to 100 % SH · CMC 1,0 % SH
CMC for the field of measured quantity: Testing of properties and defects of materials
Instrument display reading (ČSN EN 12668-1) DOC-23-00022
31 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Equivalent input noise level — 1 nV/√Hz to 80 nV/√Hz · CMC 7 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Calculation from measured values (ČSN EN 12668-1) DOC-23-00022
32 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Calibrated attenuator accuracy — 0 dB to 110 dB · CMC 0,7 dB
CMC for the field of measured quantity: Testing of properties and defects of materials
Comparison with a reference attenuator (ČSN EN 12668-1) DOC-23-00022
33 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Time base linearity — 0 µs to 5125 µs · CMC 0,004 µs
CMC for the field of measured quantity: Testing of properties and defects of materials
Simulation by el. signal (ČSN EN 12668-1) DOC-23-00022
34 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Transmit pulse voltage (PA) — 2 V to 500 V · CMC 3 % Pulse rise time (PA) — 2 ns to 1100 ns · CMC 2 % Pulse duration (PA) — 2 ns to 1100 ns · CMC 2 % Emission delay (PA) — 0 ns to 5 ns · CMC 0,08 ns Instrument absolute gain (PA) — 5 % SH to 100 % SH · CMC 0,23 % SH Transmit pulse voltage (UT) — 2 V to 500 V · CMC 3 % Pulse rise time (UT) — 2 ns to 1100 ns · CMC 2 % Pulse duration (UT) — 2 ns to 1100 ns · CMC 2 % Instrument absolute gain (UT) — 5 % SH to 100 % SH · CMC 0,23 % SH Instrument absolute gain (ECA) — 0 V to 1,5 V · CMC 0,01 V Generator excitation frequency (ECA) — 0,1 MHz to 6,1 MHz · CMC 2,0 % Output voltage verification (ECA), frequency — 1 Hz to 20 Hz · CMC 2,0 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement with an oscilloscope DOC-23-00022
35 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Bandwidth (PA) — 0,2 MHz to 26,5 MHz · CMC 2 % Display linearity (PA) — 5 % SH to 100 % SH · CMC 0,23 % SH Bandwidth (UT) — 0,2 MHz to 26,5 MHz · CMC 2 % Display linearity — 5 % SH to 100 % SH · CMC 0,23 % SH Channel gain deviation — 5 % SH to 100 % SH · CMC 0,2 % SH
CMC for the field of measured quantity: Testing of properties and defects of materials
Instrument display reading DOC-23-00022
36 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Display linearity delay (PA) — 0,01 µs to 10,01 µs · CMC 0,001 µs Display linearity delay — 0,01 µs to 10,01 µs · CMC 0,001 µs Transmit channel position deviation — 0 ns to 5 ns · CMC 0,07 ns
CMC for the field of measured quantity: Testing of properties and defects of materials
Simulation by el. signal DOC-23-00022
37 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Transmit pulse voltage (UT) — 2 V to 500 V · CMC 3 % Pulse rise time (UT) — 2 ns to 1100 ns · CMC 2 % Pulse duration (UT) — 2 ns to 1100 ns · CMC 2 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement with an oscilloscope (ČSN EN ISO 22232-1) DOC-23-00022
38 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Amplifier frequency response — 0,2 MHz to 26,5 MHz · CMC 2 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Signal generation (ČSN EN ISO 22232-1) DOC-23-00022
39 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Equivalent input noise level — 1 nV/√Hz to 80 nV/√Hz · CMC 7 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Calculation from measured values (ČSN EN ISO 22232-1) DOC-23-00022
40 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Calibrated attenuator accuracy — 0 dB to 110 dB · CMC 0,7 dB
CMC for the field of measured quantity: Testing of properties and defects of materials
Comparison with a reference attenuator (ČSN EN ISO 22232-1) DOC-23-00022
41 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Display unit vertical linearity (mm) — 5 % SH to 100 % SH · CMC 1,0 % SH
CMC for the field of measured quantity: Testing of properties and defects of materials
Instrument display reading (ČSN EN ISO 22232-1) DOC-23-00022
42 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Transmit pulse voltage — 2 V to 500 V · CMC 3 % Pulse rise time — 2 ns to 1100 ns · CMC 2 % Pulse duration — 2 ns to 1100 ns · CMC 2 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement with an oscilloscope (ČSN EN ISO 18563-1) DOC-23-00022
43 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Delay linearity — 0 ns to 100 ns · CMC 0,07 ns Linearity of individual transmit pulses — 0 ns to 55 ns · CMC 0,07 ns
CMC for the field of measured quantity: Testing of properties and defects of materials
Simulation by el. signal (ČSN EN ISO 18563-1) DOC-23-00022
44 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Amplifier frequency response — 0,2 MHz to 29 MHz · CMC 2 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Signal generation (ČSN EN ISO 18563-1) DOC-23-00022
45 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Channel gain deviation — 5 % SH to 100 % SH · CMC 0,2 % SH Vertical display linearity (mm) — 5 % SH to 800 % SH · CMC 1 % SH
CMC for the field of measured quantity: Testing of properties and defects of materials
Instrument display reading (ČSN EN ISO 18563-1) DOC-23-00022
46 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Equivalent input noise level — 1 nV/√Hz to 80 nV/√Hz · CMC 7 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Calculation from measured values (ČSN EN ISO 18563-1) DOC-23-00022
47 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Calibrated attenuator accuracy — 0 dB to 110 dB · CMC 0,7 dB
CMC for the field of measured quantity: Testing of properties and defects of materials
Comparison with a reference attenuator (ČSN EN ISO 18563-1) DOC-23-00022
48 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Gain linearity (ECA) — 0,1 % to 3,0 % · CMC 0,7 %
CMC for the field of measured quantity: Testing of properties and defects of materials
Comparison with a reference attenuator DOC-23-00022
49 Olympus/Evident Omniscan series ultrasonic flaw detectors Calibration – testing of properties and defects of materials
Output voltage verification (ECA), voltage — 1 V to 10 V · CMC 0,7 % General test (ECA), voltage on a connector — 0 V to 12 V · CMC 0,08 V General test (ECA), voltage on a BNC connector — 0 V to 12 V · CMC 0,08 V
CMC for the field of measured quantity: Testing of properties and defects of materials
Measurement by a multimeter DOC-23-00022
50 DC voltage / DC voltage sources Calibration – electrical quantities
0 mV to 10 mV · CMC 8 µV 10 mV to 100 mV · CMC 17 µV 100 mV to 1 V · CMC 88 µV 1 V to 10 V · CMC 0,8 mV 10 V to 100 V · CMC 10 mV 100 to 1000 V · CMC 65 mV
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a multimeter DOC-25-00057
51 DC resistance Calibration – electrical quantities
0 Ω to 10 Ω · CMC 10 mΩ 10 Ω to 100 Ω · CMC 29 mΩ 100 Ω to 1 kΩ · CMC 0,2 Ω 1 kΩ to 10 kΩ · CMC 2 Ω 10 kΩ to 100 kΩ · CMC 20 Ω 100 kΩ to 1 MΩ · CMC 0,2 kΩ 1 MΩ to 10 MΩ · CMC 8 kΩ 10 MΩ to 100 MΩ · CMC 0,9 MΩ
CMC for the field of measured quantity: Electrical quantities
Direct measurement by a multimeter DOC-25-00057
52 HF voltage, peak-to-peak value / Sources of peak-to-peak voltage Calibration – electrical quantities
0,1 MHz to 100 MHz — 2 mV to 40 V · CMC 3 % + 0,1 mV
CMC for the field of measured quantity: Electrical quantities
Measurement with an oscilloscope with 50 Ω external load DOC-25-00057
53 HF attenuation / HF attenuator Calibration – electrical quantities
0,25 MHz to 100 MHz — 0 dB to 50 dB · CMC 0,17 dB 0,25 MHz to 100 MHz — 50 dB to 60 dB · CMC 0,21 dB 0,25 MHz to 100 MHz — 60 dB to 70 dB · CMC 0,28 dB 0,25 MHz to 100 MHz — 70 dB to 80 dB · CMC 0,37 dB 0,25 MHz to 100 MHz — 80 dB to 90 dB · CMC 0,57 dB
CMC for the field of measured quantity: Electrical quantities
Measurement by a vector analyzer DOC-25-00057

Reference standards (5)

DOC-23-00018
DOC-23-00019
DOC-23-00021
DOC-23-00022
DOC-25-00057