🇨🇿 OPTOKON, a.s. PL

ČIA 2315 • Jihlava, Czech Republic • 23 calibration items

Metrology & calibration

OPTOKON, a.s. is a calibration laboratory accredited by ČIA under number 2315 (Jihlava, Czech Republic). Its accreditation scope covers 23 calibration items in the following areas: Metrology & calibration. Calibrated items include: Linearity / optical spectrum analysers, Optical attenuation / optical attenuator, Optical attenuation of SMF fibre / OTDR optical reflectometers, Optical length of SMF fibre / OTDR optical reflectometers. Most frequently used calibration principles: Method based on an optical fibre delay line, Comparison of measurement of optical radiation in fibre by an optic…, Comparison with a wavelength meter standard.

At a glance

  • Accreditation number: ČIA 2315
  • Calibration items in scope: 23
  • Types of calibrated items: 13
  • Calibration principles used: 12
  • City: Jihlava, Czech Republic
  • Valid until: 26-06-2031
Accreditation number
2315
Accreditation body
ČIA
Address
Červený Kříž 250, 586 01 Jihlava
City
Jihlava, Czech Republic
Division
Laboratorium wzorcujące OPTOKON
Valid until
26-06-2031

What this laboratory calibrates (13)

Calibration principles (12)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
26.06.2026

Accreditation scope — calibration items (23)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
OPTOKON Jihlava
1 Indicating (direct indicating) thermometers Calibration – temperature
-40 °C to 140 °C · CMC 0,41 °C
CMC for the field of measured quantity: Temperature
Comparison with a thermometer standard in a climatic chamber PPKL 2.8
2 Indicating (direct indicating) hygrometers Calibration – air humidity
(21 to 25) °C — 30 % RH to 90 % RH · CMC 3,7 % RH
CMC for the field of measured quantity: Air humidity
Comparison with a hygrometer standard in a climatic chamber PPKL 2.9
3 Optical power / optical power meters Calibration – optical quantities
635 nm to 980 nm — -60 dBm to -50 dBm · CMC 4,5 % 635 nm to 980 nm — -50 dBm to -40 dBm · CMC 3,2 % 635 nm to 980 nm — -40 dBm to +10 dBm · CMC 3,0 % 1270 nm to 1610 nm — -60 dBm to -50 dBm · CMC 4,2 % 1270 nm to 1610 nm — -50 dBm to -40 dBm · CMC 2,7 % 1270 nm to 1610 nm — -40 dBm to +10 dBm · CMC 2,5 % 1625 nm to 1650 nm — -60 dBm to -50 dBm · CMC 4,6 % 1625 nm to 1650 nm — -50 dBm to -40 dBm · CMC 3,2 % 1625 nm to 1650 nm — -40 dBm to +10 dBm · CMC 3,0 %
CMC for the field of measured quantity: Optical quantities
Comparison of measurement of optical radiation in fibre by an optical power meter detector with a standard optical power meter using a comparative method PPKL 2.1 (ČSN EN 61315 ed. 3)
4 Optical attenuation / optical attenuator Calibration – optical quantities
1270 nm to 1650 nm — 0 dB to 40 dB · CMC 0,26 dB 1270 nm to 1650 nm — 40 dB to 65 dB · CMC 0,30 dB
CMC for the field of measured quantity: Optical quantities
Measurement of insertion loss for individual settings of an attenuator PPKL 2.2 (ČSN EN 61300-3-4 ed. 2)
5 Wavelength / optical source for fibre optics Calibration – optical quantities
medium wavelength — 600 nm to 1700 nm · CMC 0,33 nm maximum intensity — 600 nm to 1700 nm · CMC 0,33 nm
CMC for the field of measured quantity: Optical quantities
Measurement of wavelength of optical radiation in fibre by an optical spectral analyser (OSA) PPKL 2.3 (ČSN EN 61315 ed. 3)
6 Optical return loss / optical return loss meter Calibration – optical quantities
1000 nm to 1700 nm — 3 dB to 32 dB · CMC 0,5 dB 1000 nm to 1700 nm — 32 dB to 42 dB · CMC 0,7 dB 1000 nm to 1700 nm — 42 dB to 52 dB · CMC 1,0 dB 1000 nm to 1700 nm — 52 dB to 61 dB · CMC 1,5 dB
CMC for the field of measured quantity: Optical quantities
Measurement of optical return loss and comparison with a reference value PPKL 2.4 (ČSN EN 61300-3-6 ed. 2)
7 Optical length of SMF fibre / OTDR optical reflectometers Calibration – optical quantities
1310 nm, 1550 nm, 1625 nm — 0 km to 50 km · CMC 0,40 m
CMC for the field of measured quantity: Optical quantities
Method based on an optical fibre delay line PPKL 2.5 (ČSN EN 61746-1)
8 Optical length of MMF fibre / optical reflectometers Calibration – optical quantities
850 nm, 1300 nm — 0 km to 5 km · CMC 0,20 m
CMC for the field of measured quantity: Optical quantities
Method based on an optical fibre delay line PPKL 2.5 (ČSN EN 61746-2)
9 Optical attenuation of SMF fibre / OTDR optical reflectometers Calibration – optical quantities
1310 nm, 1550 nm, 1625 nm — 0 dB to 20 dB · CMC 0,02 dB
CMC for the field of measured quantity: Optical quantities
OTDR measurement of attenuation for various power levels and various distances PPKL 2.5 (ČSN EN 61746-1)
10 Spectral responsivity / optical radiation detectors – photodiodes Newport 818-xx Calibration – optical quantities
635 nm to 940 nm, 1625 nm, 1650 nm at optical power -10 dBm to -20 dBm — 0 to 1 · CMC 3 % 1270 nm to 1610 nm at optical power -10 dBm to -20 dBm — 0 to 1 · CMC 2,6 %
CMC for the field of measured quantity: Optical quantities
Measurement of optical power and current PPKL 2.7
11 Wavelength / optical spectrum analysers Calibration – optical quantities
1250 nm to 1650 nm · CMC 0,2 nm
CMC for the field of measured quantity: Optical quantities
Comparison with a wavelength meter standard PPKL 2.6 (ČSN EN 62129-1)
12 Optical power / optical spectrum analysers Calibration – optical quantities
1250 nm to 1650 nm — -40 dBm to +10 dBm · CMC 2,5 %
CMC for the field of measured quantity: Optical quantities
Comparison with an optical power meter standard PPKL 2.1 (ČSN EN 61315 ed. 2)
13 Linearity / optical spectrum analysers Calibration – optical quantities
1310 nm, 1550 nm — -60 dBm to -50 dBm · CMC 0,24 dB 1310 nm, 1550 nm — -50 dBm to -40 dBm · CMC 0,09 dB 1310 nm, 1550 nm — -40 dBm to 0 dBm · CMC 0,05 dB
CMC for the field of measured quantity: Optical quantities
Comparison with an optical power meter standard using an optical attenuator PPKL 2.6 (ČSN EN 62129-1)
OPTOKON Malaysia
14 Optical power / optical power meters Calibration – optical quantities
635 nm to 980 nm — -60 dBm to -50 dBm · CMC 4,5 % 635 nm to 980 nm — -50 dBm to -40 dBm · CMC 3,2 % 635 nm to 980 nm — -40 dBm to +10 dBm · CMC 3,0 % 1270 nm to 1610 nm — -60 dBm to -50 dBm · CMC 4,2 % 1270 nm to 1610 nm — -50 dBm to -40 dBm · CMC 2,7 % 1270 nm to 1610 nm — -40 dBm to +10 dBm · CMC 2,5 % 1625 nm to 1650 nm — -60 dBm to -50 dBm · CMC 4,6 % 1625 nm to 1650 nm — -50 dBm to -40 dBm · CMC 3,2 % 1625 nm to 1650 nm — -40 dBm to +10 dBm · CMC 3,0 %
CMC for the field of measured quantity: Optical quantities
Comparison of measurement of optical radiation in fibre by an optical power meter detector with a standard optical power meter using a comparative method PPKL 2.1 (ČSN EN 61315 ed. 3)
15 Optical attenuation / optical attenuator Calibration – optical quantities
1270 nm to 1650 nm — 0 dB to 40 dB · CMC 0,26 dB 1270 nm to 1650 nm — 40 dB to 65 dB · CMC 0,30 dB
CMC for the field of measured quantity: Optical quantities
Measurement of insertion loss for individual settings of an attenuator PPKL 2.2 (ČSN EN 61300-3-4 ed. 2)
16 Wavelength / optical source for fibre optics Calibration – optical quantities
medium wavelength — 600 nm to 1700 nm · CMC 0,33 nm maximum intensity — 600 nm to 1700 nm · CMC 0,33 nm
CMC for the field of measured quantity: Optical quantities
Measurement of wavelength of optical radiation in fibre by an optical spectral analyser (OSA) PPKL 2.3 (ČSN EN 61315 ed. 3)
17 Optical return loss / optical return loss meter Calibration – optical quantities
1000 nm to 1700 nm — 3 dB to 32 dB · CMC 0,5 dB 1000 nm to 1700 nm — 32 dB to 42 dB · CMC 0,7 dB 1000 nm to 1700 nm — 42 dB to 52 dB · CMC 1,0 dB 1000 nm to 1700 nm — 52 dB to 61 dB · CMC 1,5 dB
CMC for the field of measured quantity: Optical quantities
Measurement of optical return loss and comparison with a reference value PPKL 2.4 (ČSN EN 61300-3-6 ed. 2)
18 Optical length of SMF fibre / OTDR optical reflectometers Calibration – optical quantities
1310 nm, 1550 nm, 1625 nm — 0 km to 50 km · CMC 0,40 m
CMC for the field of measured quantity: Optical quantities
Method based on an optical fibre delay line PPKL 2.5 (ČSN EN 61746-1)
19 Optical attenuation of SMF fibre / OTDR optical reflectometers Calibration – optical quantities
1310 nm, 1550 nm, 1625 nm — 0 dB to 20 dB · CMC 0,02 dB
CMC for the field of measured quantity: Optical quantities
OTDR measurement of attenuation for various power levels and various distances PPKL 2.5 (ČSN EN 61746-1)
20 Spectral responsivity / optical radiation detectors – photodiodes Newport 818-xx Calibration – optical quantities
635 nm to 940 nm, 1625 nm, 1650 nm at optical power -10 dBm to -20 dBm — 0 to 1 · CMC 3 % 1270 nm to 1610 nm at optical power -10 dBm to -20 dBm — 0 to 1 · CMC 2,6 %
CMC for the field of measured quantity: Optical quantities
Measurement of optical power and current PPKL 2.7
21 Wavelength / optical spectrum analysers Calibration – optical quantities
1250 nm to 1650 nm · CMC 0,2 nm
CMC for the field of measured quantity: Optical quantities
Comparison with a wavelength meter standard PPKL 2.6 (ČSN EN 62129-1)
22 Optical power / optical spectrum analysers Calibration – optical quantities
1250 nm to 1650 nm — -40 dBm to +10 dBm · CMC 2,5 %
CMC for the field of measured quantity: Optical quantities
Comparison with an optical power meter standard PPKL 2.1 (ČSN EN 61315 ed. 2)
23 Linearity / optical spectrum analysers Calibration – optical quantities
1310 nm, 1550 nm — -60 dBm to -50 dBm · CMC 0,24 dB 1310 nm, 1550 nm — -50 dBm to -40 dBm · CMC 0,09 dB 1310 nm, 1550 nm — -40 dBm to 0 dBm · CMC 0,05 dB
CMC for the field of measured quantity: Optical quantities
Comparison with an optical power meter standard using an optical attenuator PPKL 2.6 (ČSN EN 62129-1)

Reference standards (16)

PPKL 2.1
PPKL 2.2
PPKL 2.3
PPKL 2.4
PPKL 2.5
PPKL 2.6
PPKL 2.7
PPKL 2.8
PPKL 2.9
ČSN EN 61300-3-4 ed. 2
ČSN EN 61300-3-6 ed. 2
ČSN EN 61315 ed. 2
ČSN EN 61315 ed. 3
ČSN EN 61746-1
ČSN EN 61746-2
ČSN EN 62129-1

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2315