{"lab":{"_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","address":"Červený Kříž 250, 586 01 Jihlava","categories":["metrology"],"city":"Jihlava","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[15.6061744,49.4576131]},"map_coord":[49.4576131,15.6061744],"map_geo":"cai-mapa","methods_count":23,"name":"OPTOKON, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: temperatura, wilgotność powietrza i wielkości optyczne, w zakresie określonym w załączniku do świadectwa.","search_text":"optokon, a.s. červený kříž 250, 586 01 jihlava 2315","source_page_url":"https://www.cai.cz/?subjekt=2315-optokon-a-s","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"26-06-2031","website":"www.optokon.com","certificate_date":"26.06.2026","certificate_no":"317/2026","certificate_replaces":"317/2025 z 27.06.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: temperatura, wilgotność powietrza i wielkości optyczne, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the fields of temperature, air humidity and optical quantities to the extent as specified in the appendix to this Certificate.","zh":"温度、空气湿度和光学量领域的校准，范围见本证书附件。","cs":"Kalibrace v oboru teplota, vlhkost vzduchu a optické veličiny, vymezené přílohou tohoto osvědčení.","de":"Kalibrierung in den Bereichen: Temperatur, Luftfeuchte und optische Größen, im Umfang gemäß Anlage zur Akkreditierungsurkunde."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące OPTOKON","lab_division_cs":"Kalibrační laboratoř OPTOKON","lab_division_en":"OPTOKON calibration laboratory","lab_division_zh":"OPTOKON 校准实验室","lab_locations":[{"code":null,"name":"OPTOKON, a.s.","street":"Červený Kříž 250","postal_code":"586 01","city":"Jihlava","is_hq":true,"address":"Červený Kříž 250, 586 01 Jihlava","site":"58601|červenýkříž250"},{"code":null,"name":"OPTOKON Jihlava","street":"Červený Kříž 250","postal_code":"586 01","city":"Jihlava, ČR","is_hq":false,"address":"Červený Kříž 250, 586 01 Jihlava, ČR","site":"58601|červenýkříž250"},{"code":null,"name":"OPTOKON Malezja","street":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah","postal_code":"119 00","city":"Bayan Lepas, Penang, MALAYSIA","is_hq":false,"address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 119 00 Bayan Lepas, Penang, MALAYSIA","site":"11900|303-4-25krystalpointjalansultanazlanshah"}],"lab_locations_en":[{"code":null,"name":"OPTOKON, a.s.","street":"Červený Kříž 250","postal_code":"586 01","city":"Jihlava","is_hq":true,"address":"Červený Kříž 250, 586 01 Jihlava","site":"58601|červenýkříž250"},{"code":null,"name":"OPTOKON Jihlava","street":"Červený Kříž 250","postal_code":"586 01","city":"Jihlava, ČR","is_hq":false,"address":"Červený Kříž 250, 586 01 Jihlava, ČR","site":"58601|červenýkříž250"},{"code":null,"name":"OPTOKON Malaysia","street":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah","postal_code":"119 00","city":"Bayan Lepas, Penang, MALAYSIA","is_hq":false,"address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 119 00 Bayan Lepas, Penang, MALAYSIA","site":"11900|303-4-25krystalpointjalansultanazlanshah"}],"lab_locations_zh":[{"code":null,"name":"OPTOKON, a.s.","street":"Červený Kříž 250","postal_code":"586 01","city":"Jihlava","is_hq":true,"address":"Červený Kříž 250, 586 01 Jihlava","site":"58601|červenýkříž250"},{"code":null,"name":"OPTOKON 伊赫拉瓦","street":"Červený Kříž 250","postal_code":"586 01","city":"Jihlava, ČR","is_hq":false,"address":"Červený Kříž 250, 586 01 Jihlava, ČR","site":"58601|červenýkříž250"},{"code":null,"name":"OPTOKON 马来西亚","street":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah","postal_code":"119 00","city":"Bayan Lepas, Penang, MALAYSIA","is_hq":false,"address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 119 00 Bayan Lepas, Penang, MALAYSIA","site":"11900|303-4-25krystalpointjalansultanazlanshah"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"a8f5abfa340bac5a83091dd8e515ce123eb9caa2d731f22dd361dab9763cb62d","source_pdf_url":"https://www.cai.cz/OA/pdf/317_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/317_2026_EN.pdf","has_de":true,"lab_division_de":"Kalibrierlabor OPTOKON","lab_locations_de":[{"code":null,"name":"OPTOKON, a.s.","street":"Červený Kříž 250","postal_code":"586 01","city":"Jihlava","is_hq":true,"address":"Červený Kříž 250, 586 01 Jihlava","site":"58601|červenýkříž250"},{"code":null,"name":"OPTOKON Jihlava","street":"Červený Kříž 250","postal_code":"586 01","city":"Jihlava, ČR","is_hq":false,"address":"Červený Kříž 250, 586 01 Jihlava, ČR","site":"58601|červenýkříž250"},{"code":null,"name":"OPTOKON Malaysia","street":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah","postal_code":"119 00","city":"Bayan Lepas, Penang, MALAYSIA","is_hq":false,"address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 119 00 Bayan Lepas, Penang, MALAYSIA","site":"11900|303-4-25krystalpointjalansultanazlanshah"}],"lab_locations_cs":[{"code":null,"name":"OPTOKON, a.s.","street":"Červený Kříž 250","postal_code":"586 01","city":"Jihlava","is_hq":true,"address":"Červený Kříž 250, 586 01 Jihlava","site":"58601|červenýkříž250"},{"code":null,"name":"OPTOKON Jihlava","street":"Červený Kříž 250","postal_code":"586 01","city":"Jihlava, ČR","is_hq":false,"address":"Červený Kříž 250, 586 01 Jihlava, ČR","site":"58601|červenýkříž250"},{"code":null,"name":"OPTOKON Malaysia","street":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah","postal_code":"119 00","city":"Bayan Lepas, Penang, MALAYSIA","is_hq":false,"address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 119 00 Bayan Lepas, Penang, MALAYSIA","site":"11900|303-4-25krystalpointjalansultanazlanshah"}]},"methods":[{"_id":"cbdf7d7e131a3b739cbff5f9","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"1","test_object":"Termometry wskazujące (bezpośrednio wskazujące)","test_object_en":"Indicating (direct indicating) thermometers","test_object_zh":"指示式（直读式）温度计","test_object_cs":"Indikační (přímoukazující) teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -40 °C do 140 °C","cmc":"0,41 °C"}],"parameters_en":[{"name":"","range":"from -40 °C to 140 °C","cmc":"0,41 °C"}],"parameters_zh":[{"name":"","range":"-40 °C 至 140 °C","cmc":"0,41 °C"}],"parameters_cs":[{"name":"","range":"-40 °C až 140 °C","cmc":"0,41 °C"}],"technique":"Porównanie z termometrem wzorcowym w komorze klimatycznej","technique_en":"Comparison with a thermometer standard in a climatic chamber","technique_zh":"在气候箱中与标准温度计比较","technique_cs":"Porovnání s etalonovým teploměrem v klimatické komoře","techniques":["Porównanie z termometrem wzorcowym w komorze klimatycznej"],"techniques_en":["Comparison with a thermometer standard in a climatic chamber"],"techniques_zh":["在气候箱中与标准温度计比较"],"techniques_cs":["Porovnání s etalonovým teploměrem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -40 °C do 140 °C CMC 0,41 °C\nPorównanie z termometrem wzorcowym w komorze klimatycznej","reference":"PPKL 2.8","norm_bases":["PPKL 2.8"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry wskazujące (bezpośrednio wskazujące) Wzorcowanie – temperatura Porównanie z termometrem wzorcowym w komorze klimatycznej od -40 °C do 140 °C CMC 0,41 °C Indikační (přímoukazující) teploměry Kalibrace – teplota Porovnání s etalonovým teploměrem v klimatické komoře -40 °C až 140 °C CMC 0,41 °C PPKL 2.8 Termometry wskazujace (bezposrednio wskazujace) Wzorcowanie – temperatura Porownanie z termometrem wzorcowym w komorze klimatycznej od -40 °C do 140 °C CMC 0,41 °C Indikacni (primoukazujici) teplomery Kalibrace – teplota Porovnani s etalonovym teplomerem v klimaticke komore -40 °C az 140 °C CMC 0,41 °C PPKL 2.8","search_en":"Indicating (direct indicating) thermometers Calibration – temperature Comparison with a thermometer standard in a climatic chamber OPTOKON Jihlava CMC for the field of measured quantity: Temperature Comparison with a thermometer standard in a climatic chamber PPKL 2.8","search_zh":"指示式（直读式）温度计 校准 – 温度 在气候箱中与标准温度计比较 OPTOKON 伊赫拉瓦 被测量领域的CMC：温度 在气候箱中与标准温度计比较 PPKL 2.8","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – Temperatur","parameters_de":[{"name":"","range":"von -40 °C bis 140 °C","cmc":"0,41 °C"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Temperatur","search_de":"Anzeigende Thermometer (direkt anzeigend) Kalibrierung – Temperatur Vergleich mit einem Referenzthermometer in der Klimakammer OPTOKON Jihlava CMC für den Messgrößenbereich: Temperatur Vergleich mit einem Referenzthermometer in der Klimakammer PPKL 2.8","technique_de":"Vergleich mit einem Referenzthermometer in der Klimakammer","techniques_de":["Vergleich mit einem Referenzthermometer in der Klimakammer"],"test_object_de":"Anzeigende Thermometer (direkt anzeigend)"},{"_id":"c31a26b825db21e627c30704","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"1","test_object":"Wilgotnościomierze wskazujące (bezpośrednio wskazujące)","test_object_en":"Indicating (direct indicating) hygrometers","test_object_zh":"指示式（直读式）湿度计","test_object_cs":"Indikační (přímoukazující) vlhkoměry","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"(21 do 25) °C","range":"od 30 % RH do 90 % RH","cmc":"3,7 % RH"}],"parameters_en":[{"name":"(21 to 25) °C","range":"30 % RH to 90 % RH","cmc":"3,7 % RH"}],"parameters_zh":[{"name":"(21 至 25) °C","range":"30 % RH 至 90 % RH","cmc":"3,7 % RH"}],"parameters_cs":[{"name":"(21 až 25) °C","range":"30 % RH až 90 % RH","cmc":"3,7 % RH"}],"technique":"Porównanie z wilgotnościomierzem wzorcowym w komorze klimatycznej","technique_en":"Comparison with a hygrometer standard in a climatic chamber","technique_zh":"在气候箱中与标准湿度计比较","technique_cs":"Porovnání s etalonovým vlhkoměrem v klimatické komoře","techniques":["Porównanie z wilgotnościomierzem wzorcowym w komorze klimatycznej"],"techniques_en":["Comparison with a hygrometer standard in a climatic chamber"],"techniques_zh":["在气候箱中与标准湿度计比较"],"techniques_cs":["Porovnání s etalonovým vlhkoměrem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\n(21 do 25) °C od 30 % RH do 90 % RH CMC 3,7 % RH\nPorównanie z wilgotnościomierzem wzorcowym w komorze klimatycznej","reference":"PPKL 2.9","norm_bases":["PPKL 2.9"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wilgotnościomierze wskazujące (bezpośrednio wskazujące) Wzorcowanie – wilgotność powietrza Porównanie z wilgotnościomierzem wzorcowym w komorze klimatycznej (21 do 25) °C od 30 % RH do 90 % RH CMC 3,7 % RH Indikační (přímoukazující) vlhkoměry Kalibrace – vlhkost vzduchu Porovnání s etalonovým vlhkoměrem v klimatické komoře (21 až 25) °C 30 % RH až 90 % RH CMC 3,7 % RH PPKL 2.9 Wilgotnosciomierze wskazujace (bezposrednio wskazujace) Wzorcowanie – wilgotnosc powietrza Porownanie z wilgotnosciomierzem wzorcowym w komorze klimatycznej (21 do 25) °C od 30 % RH do 90 % RH CMC 3,7 % RH Indikacni (primoukazujici) vlhkomery Kalibrace – vlhkost vzduchu Porovnani s etalonovym vlhkomerem v klimaticke komore (21 az 25) °C 30 % RH az 90 % RH CMC 3,7 % RH PPKL 2.9","search_en":"Indicating (direct indicating) hygrometers Calibration – air humidity Comparison with a hygrometer standard in a climatic chamber OPTOKON Jihlava CMC for the field of measured quantity: Air humidity Comparison with a hygrometer standard in a climatic chamber (21 to 25) °C PPKL 2.9","search_zh":"指示式（直读式）湿度计 校准 – 空气湿度 在气候箱中与标准湿度计比较 OPTOKON 伊赫拉瓦 被测量领域的CMC：空气湿度 在气候箱中与标准湿度计比较 (21 至 25) °C PPKL 2.9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – Luftfeuchte","parameters_de":[{"name":"(21 bis 25) °C","range":"von 30 % RH bis 90 % RH","cmc":"3,7 % RH"}],"regulatory_area_de":"CMC für den Messgrößenbereich: Luftfeuchte","search_de":"Anzeigende Feuchtemessgeräte (direkt anzeigend) Kalibrierung – Luftfeuchte Vergleich mit Normal-Feuchtemessgerät in der Klimakammer OPTOKON Jihlava CMC für den Messgrößenbereich: Luftfeuchte Vergleich mit Normal-Feuchtemessgerät in der Klimakammer (21 bis 25) °C PPKL 2.9","technique_de":"Vergleich mit Normal-Feuchtemessgerät in der Klimakammer","techniques_de":["Vergleich mit Normal-Feuchtemessgerät in der Klimakammer"],"test_object_de":"Anzeigende Feuchtemessgeräte (direkt anzeigend)"},{"_id":"48a129cd4b995b16a695ceb6","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"1","test_object":"Moc optyczna / mierniki mocy optycznej","test_object_en":"Optical power / optical power meters","test_object_zh":"光功率 / 光功率计","test_object_cs":"Optický výkon / měřidla optického výkonu","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"635 nm do 980 nm","range":"od -60 dBm do -50 dBm","cmc":"4,5 %"},{"name":"635 nm do 980 nm","range":"od -50 dBm do -40 dBm","cmc":"3,2 %"},{"name":"635 nm do 980 nm","range":"od -40 dBm do +10 dBm","cmc":"3,0 %"},{"name":"1270 nm do 1610 nm","range":"od -60 dBm do -50 dBm","cmc":"4,2 %"},{"name":"1270 nm do 1610 nm","range":"od -50 dBm do -40 dBm","cmc":"2,7 %"},{"name":"1270 nm do 1610 nm","range":"od -40 dBm do +10 dBm","cmc":"2,5 %"},{"name":"1625 nm do 1650 nm","range":"od -60 dBm do -50 dBm","cmc":"4,6 %"},{"name":"1625 nm do 1650 nm","range":"od -50 dBm do -40 dBm","cmc":"3,2 %"},{"name":"1625 nm do 1650 nm","range":"od -40 dBm do +10 dBm","cmc":"3,0 %"}],"parameters_en":[{"name":"635 nm to 980 nm","range":"-60 dBm to -50 dBm","cmc":"4,5 %"},{"name":"635 nm to 980 nm","range":"-50 dBm to -40 dBm","cmc":"3,2 %"},{"name":"635 nm to 980 nm","range":"-40 dBm to +10 dBm","cmc":"3,0 %"},{"name":"1270 nm to 1610 nm","range":"-60 dBm to -50 dBm","cmc":"4,2 %"},{"name":"1270 nm to 1610 nm","range":"-50 dBm to -40 dBm","cmc":"2,7 %"},{"name":"1270 nm to 1610 nm","range":"-40 dBm to +10 dBm","cmc":"2,5 %"},{"name":"1625 nm to 1650 nm","range":"-60 dBm to -50 dBm","cmc":"4,6 %"},{"name":"1625 nm to 1650 nm","range":"-50 dBm to -40 dBm","cmc":"3,2 %"},{"name":"1625 nm to 1650 nm","range":"-40 dBm to +10 dBm","cmc":"3,0 %"}],"parameters_zh":[{"name":"635 nm 至 980 nm","range":"-60 dBm 至 -50 dBm","cmc":"4,5 %"},{"name":"635 nm 至 980 nm","range":"-50 dBm 至 -40 dBm","cmc":"3,2 %"},{"name":"635 nm 至 980 nm","range":"-40 dBm 至 +10 dBm","cmc":"3,0 %"},{"name":"1270 nm 至 1610 nm","range":"-60 dBm 至 -50 dBm","cmc":"4,2 %"},{"name":"1270 nm 至 1610 nm","range":"-50 dBm 至 -40 dBm","cmc":"2,7 %"},{"name":"1270 nm 至 1610 nm","range":"-40 dBm 至 +10 dBm","cmc":"2,5 %"},{"name":"1625 nm 至 1650 nm","range":"-60 dBm 至 -50 dBm","cmc":"4,6 %"},{"name":"1625 nm 至 1650 nm","range":"-50 dBm 至 -40 dBm","cmc":"3,2 %"},{"name":"1625 nm 至 1650 nm","range":"-40 dBm 至 +10 dBm","cmc":"3,0 %"}],"parameters_cs":[{"name":"635 nm až 980 nm","range":"-60 dBm až -50 dBm","cmc":"4,5 %"},{"name":"635 nm až 980 nm","range":"-50 dBm až -40 dBm","cmc":"3,2 %"},{"name":"635 nm až 980 nm","range":"-40 dBm až +10 dBm","cmc":"3,0 %"},{"name":"1270 nm až 1610 nm","range":"-60 dBm až -50 dBm","cmc":"4,2 %"},{"name":"1270 nm až 1610 nm","range":"-50 dBm až -40 dBm","cmc":"2,7 %"},{"name":"1270 nm až 1610 nm","range":"-40 dBm až +10 dBm","cmc":"2,5 %"},{"name":"1625 nm až 1650 nm","range":"-60 dBm až -50 dBm","cmc":"4,6 %"},{"name":"1625 nm až 1650 nm","range":"-50 dBm až -40 dBm","cmc":"3,2 %"},{"name":"1625 nm až 1650 nm","range":"-40 dBm až +10 dBm","cmc":"3,0 %"}],"technique":"Porównanie pomiaru mocy promieniowania optycznego we włóknie detektorem miernika mocy optycznej z wzorcowym miernikiem mocy optycznej metodą porównawczą","technique_en":"Comparison of measurement of optical radiation in fibre by an optical power meter detector with a standard optical power meter using a comparative method","technique_zh":"用比较法将光功率计探测器对光纤中光辐射功率的测量与标准光功率计比较","technique_cs":"Porovnání měření výkonu optického záření ve vláknu detektorem měřidla optického výkonu s etalonovým měřidlem optického výkonu komparační metodou","techniques":["Porównanie pomiaru mocy promieniowania optycznego we włóknie detektorem miernika mocy optycznej z wzorcowym miernikiem mocy optycznej metodą porównawczą"],"techniques_en":["Comparison of measurement of optical radiation in fibre by an optical power meter detector with a standard optical power meter using a comparative method"],"techniques_zh":["用比较法将光功率计探测器对光纤中光辐射功率的测量与标准光功率计比较"],"techniques_cs":["Porovnání měření výkonu optického záření ve vláknu detektorem měřidla optického výkonu s etalonovým měřidlem optického výkonu komparační metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\n635 nm do 980 nm od -60 dBm do -50 dBm CMC 4,5 %\n635 nm do 980 nm od -50 dBm do -40 dBm CMC 3,2 %\n635 nm do 980 nm od -40 dBm do +10 dBm CMC 3,0 %\n1270 nm do 1610 nm od -60 dBm do -50 dBm CMC 4,2 %\n1270 nm do 1610 nm od -50 dBm do -40 dBm CMC 2,7 %\n1270 nm do 1610 nm od -40 dBm do +10 dBm CMC 2,5 %\n1625 nm do 1650 nm od -60 dBm do -50 dBm CMC 4,6 %\n1625 nm do 1650 nm od -50 dBm do -40 dBm CMC 3,2 %\n1625 nm do 1650 nm od -40 dBm do +10 dBm CMC 3,0 %\nPorównanie pomiaru mocy promieniowania optycznego we włóknie detektorem miernika mocy optycznej z wzorcowym miernikiem mocy optycznej metodą porównawczą","reference":"PPKL 2.1 (ČSN EN 61315 ed. 3)","norm_bases":["PPKL 2.1","ČSN EN 61315 ed. 3"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc optyczna / mierniki mocy optycznej Wzorcowanie – wielkości optyczne Porównanie pomiaru mocy promieniowania optycznego we włóknie detektorem miernika mocy optycznej z wzorcowym miernikiem mocy optycznej metodą porównawczą 635 nm do 980 nm od -60 dBm do -50 dBm CMC 4,5 % 635 nm do 980 nm od -50 dBm do -40 dBm CMC 3,2 % 635 nm do 980 nm od -40 dBm do +10 dBm CMC 3,0 % 1270 nm do 1610 nm od -60 dBm do -50 dBm CMC 4,2 % 1270 nm do 1610 nm od -50 dBm do -40 dBm CMC 2,7 % 1270 nm do 1610 nm od -40 dBm do +10 dBm CMC 2,5 % 1625 nm do 1650 nm od -60 dBm do -50 dBm CMC 4,6 % 1625 nm do 1650 nm od -50 dBm do -40 dBm CMC 3,2 % 1625 nm do 1650 nm od -40 dBm do +10 dBm CMC 3,0 % Optický výkon / měřidla optického výkonu Kalibrace – optické veličiny Porovnání měření výkonu optického záření ve vláknu detektorem měřidla optického výkonu s etalonovým měřidlem optického výkonu komparační metodou 635 nm až 980 nm -60 dBm až -50 dBm CMC 4,5 % 635 nm až 980 nm -50 dBm až -40 dBm CMC 3,2 % 635 nm až 980 nm -40 dBm až +10 dBm CMC 3,0 % 1270 nm až 1610 nm -60 dBm až -50 dBm CMC 4,2 % 1270 nm až 1610 nm -50 dBm až -40 dBm CMC 2,7 % 1270 nm až 1610 nm -40 dBm až +10 dBm CMC 2,5 % 1625 nm až 1650 nm -60 dBm až -50 dBm CMC 4,6 % 1625 nm až 1650 nm -50 dBm až -40 dBm CMC 3,2 % 1625 nm až 1650 nm -40 dBm až +10 dBm CMC 3,0 % PPKL 2.1 (ČSN EN 61315 ed. 3) Moc optyczna / mierniki mocy optycznej Wzorcowanie – wielkosci optyczne Porownanie pomiaru mocy promieniowania optycznego we wloknie detektorem miernika mocy optycznej z wzorcowym miernikiem mocy optycznej metoda porownawcza 635 nm do 980 nm od -60 dBm do -50 dBm CMC 4,5 % 635 nm do 980 nm od -50 dBm do -40 dBm CMC 3,2 % 635 nm do 980 nm od -40 dBm do +10 dBm CMC 3,0 % 1270 nm do 1610 nm od -60 dBm do -50 dBm CMC 4,2 % 1270 nm do 1610 nm od -50 dBm do -40 dBm CMC 2,7 % 1270 nm do 1610 nm od -40 dBm do +10 dBm CMC 2,5 % 1625 nm do 1650 nm od -60 dBm do -50 dBm CMC 4,6 % 1625 nm do 1650 nm od -50 dBm do -40 dBm CMC 3,2 % 1625 nm do 1650 nm od -40 dBm do +10 dBm CMC 3,0 % Opticky vykon / meridla optickeho vykonu Kalibrace – opticke veliciny Porovnani mereni vykonu optickeho zareni ve vlaknu detektorem meridla optickeho vykonu s etalonovym meridlem optickeho vykonu komparacni metodou 635 nm az 980 nm -60 dBm az -50 dBm CMC 4,5 % 635 nm az 980 nm -50 dBm az -40 dBm CMC 3,2 % 635 nm az 980 nm -40 dBm az +10 dBm CMC 3,0 % 1270 nm az 1610 nm -60 dBm az -50 dBm CMC 4,2 % 1270 nm az 1610 nm -50 dBm az -40 dBm CMC 2,7 % 1270 nm az 1610 nm -40 dBm az +10 dBm CMC 2,5 % 1625 nm az 1650 nm -60 dBm az -50 dBm CMC 4,6 % 1625 nm az 1650 nm -50 dBm az -40 dBm CMC 3,2 % 1625 nm az 1650 nm -40 dBm az +10 dBm CMC 3,0 % PPKL 2.1 (CSN EN 61315 ed. 3)","search_en":"Optical power / optical power meters Calibration – optical quantities Comparison of measurement of optical radiation in fibre by an optical power meter detector with a standard optical power meter using a comparative method OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities Comparison of measurement of optical radiation in fibre by an optical power meter detector with a standard optical power meter using a comparative method 635 nm to 980 nm 635 nm to 980 nm 635 nm to 980 nm 1270 nm to 1610 nm 1270 nm to 1610 nm 1270 nm to 1610 nm 1625 nm to 1650 nm 1625 nm to 1650 nm 1625 nm to 1650 nm PPKL 2.1 (ČSN EN 61315 ed. 3)","search_zh":"光功率 / 光功率计 校准 – 光学量 用比较法将光功率计探测器对光纤中光辐射功率的测量与标准光功率计比较 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 用比较法将光功率计探测器对光纤中光辐射功率的测量与标准光功率计比较 635 nm 至 980 nm 635 nm 至 980 nm 635 nm 至 980 nm 1270 nm 至 1610 nm 1270 nm 至 1610 nm 1270 nm 至 1610 nm 1625 nm 至 1650 nm 1625 nm 至 1650 nm 1625 nm 至 1650 nm PPKL 2.1 (ČSN EN 61315 第3版)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"635 nm bis 980 nm","range":"von -60 dBm bis -50 dBm","cmc":"4,5 %"},{"name":"635 nm bis 980 nm","range":"von -50 dBm bis -40 dBm","cmc":"3,2 %"},{"name":"635 nm bis 980 nm","range":"von -40 dBm bis +10 dBm","cmc":"3,0 %"},{"name":"1270 nm bis 1610 nm","range":"von -60 dBm bis -50 dBm","cmc":"4,2 %"},{"name":"1270 nm bis 1610 nm","range":"von -50 dBm bis -40 dBm","cmc":"2,7 %"},{"name":"1270 nm bis 1610 nm","range":"von -40 dBm bis +10 dBm","cmc":"2,5 %"},{"name":"1625 nm bis 1650 nm","range":"von -60 dBm bis -50 dBm","cmc":"4,6 %"},{"name":"1625 nm bis 1650 nm","range":"von -50 dBm bis -40 dBm","cmc":"3,2 %"},{"name":"1625 nm bis 1650 nm","range":"von -40 dBm bis +10 dBm","cmc":"3,0 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Leistung / optische Leistungsmessgeräte Kalibrierung – optische Größen Vergleich der Messung der optischen Strahlungsleistung im Lichtwellenleiter mit dem Detektor des optischen Leistungsmessers mit einem optischen Referenz-Leistungsmesser im Vergleichsverfahren OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen Vergleich der Messung der optischen Strahlungsleistung im Lichtwellenleiter mit dem Detektor des optischen Leistungsmessers mit einem optischen Referenz-Leistungsmesser im Vergleichsverfahren 635 nm bis 980 nm 635 nm bis 980 nm 635 nm bis 980 nm 1270 nm bis 1610 nm 1270 nm bis 1610 nm 1270 nm bis 1610 nm 1625 nm bis 1650 nm 1625 nm bis 1650 nm 1625 nm bis 1650 nm PPKL 2.1 (ČSN EN 61315 Ausg. 3)","technique_de":"Vergleich der Messung der optischen Strahlungsleistung im Lichtwellenleiter mit dem Detektor des optischen Leistungsmessers mit einem optischen Referenz-Leistungsmesser im Vergleichsverfahren","techniques_de":["Vergleich der Messung der optischen Strahlungsleistung im Lichtwellenleiter mit dem Detektor des optischen Leistungsmessers mit einem optischen Referenz-Leistungsmesser im Vergleichsverfahren"],"test_object_de":"Optische Leistung / optische Leistungsmessgeräte","reference_de":"PPKL 2.1 (ČSN EN 61315 Ausg. 3)","reference_zh":"PPKL 2.1 (ČSN EN 61315 第3版)","reference_pl":"PPKL 2.1 (ČSN EN 61315 wyd. 3)"},{"_id":"181731e1d07e657855577cfc","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"1","test_object":"Moc optyczna / mierniki mocy optycznej","test_object_en":"Optical power / optical power meters","test_object_zh":"光功率 / 光功率计","test_object_cs":"Optický výkon / měřidla optického výkonu","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"635 nm do 980 nm","range":"od -60 dBm do -50 dBm","cmc":"4,5 %"},{"name":"635 nm do 980 nm","range":"od -50 dBm do -40 dBm","cmc":"3,2 %"},{"name":"635 nm do 980 nm","range":"od -40 dBm do +10 dBm","cmc":"3,0 %"},{"name":"1270 nm do 1610 nm","range":"od -60 dBm do -50 dBm","cmc":"4,2 %"},{"name":"1270 nm do 1610 nm","range":"od -50 dBm do -40 dBm","cmc":"2,7 %"},{"name":"1270 nm do 1610 nm","range":"od -40 dBm do +10 dBm","cmc":"2,5 %"},{"name":"1625 nm do 1650 nm","range":"od -60 dBm do -50 dBm","cmc":"4,6 %"},{"name":"1625 nm do 1650 nm","range":"od -50 dBm do -40 dBm","cmc":"3,2 %"},{"name":"1625 nm do 1650 nm","range":"od -40 dBm do +10 dBm","cmc":"3,0 %"}],"parameters_en":[{"name":"635 nm to 980 nm","range":"-60 dBm to -50 dBm","cmc":"4,5 %"},{"name":"635 nm to 980 nm","range":"-50 dBm to -40 dBm","cmc":"3,2 %"},{"name":"635 nm to 980 nm","range":"-40 dBm to +10 dBm","cmc":"3,0 %"},{"name":"1270 nm to 1610 nm","range":"-60 dBm to -50 dBm","cmc":"4,2 %"},{"name":"1270 nm to 1610 nm","range":"-50 dBm to -40 dBm","cmc":"2,7 %"},{"name":"1270 nm to 1610 nm","range":"-40 dBm to +10 dBm","cmc":"2,5 %"},{"name":"1625 nm to 1650 nm","range":"-60 dBm to -50 dBm","cmc":"4,6 %"},{"name":"1625 nm to 1650 nm","range":"-50 dBm to -40 dBm","cmc":"3,2 %"},{"name":"1625 nm to 1650 nm","range":"-40 dBm to +10 dBm","cmc":"3,0 %"}],"parameters_zh":[{"name":"635 nm 至 980 nm","range":"-60 dBm 至 -50 dBm","cmc":"4,5 %"},{"name":"635 nm 至 980 nm","range":"-50 dBm 至 -40 dBm","cmc":"3,2 %"},{"name":"635 nm 至 980 nm","range":"-40 dBm 至 +10 dBm","cmc":"3,0 %"},{"name":"1270 nm 至 1610 nm","range":"-60 dBm 至 -50 dBm","cmc":"4,2 %"},{"name":"1270 nm 至 1610 nm","range":"-50 dBm 至 -40 dBm","cmc":"2,7 %"},{"name":"1270 nm 至 1610 nm","range":"-40 dBm 至 +10 dBm","cmc":"2,5 %"},{"name":"1625 nm 至 1650 nm","range":"-60 dBm 至 -50 dBm","cmc":"4,6 %"},{"name":"1625 nm 至 1650 nm","range":"-50 dBm 至 -40 dBm","cmc":"3,2 %"},{"name":"1625 nm 至 1650 nm","range":"-40 dBm 至 +10 dBm","cmc":"3,0 %"}],"parameters_cs":[{"name":"635 nm až 980 nm","range":"-60 dBm až -50 dBm","cmc":"4,5 %"},{"name":"635 nm až 980 nm","range":"-50 dBm až -40 dBm","cmc":"3,2 %"},{"name":"635 nm až 980 nm","range":"-40 dBm až +10 dBm","cmc":"3,0 %"},{"name":"1270 nm až 1610 nm","range":"-60 dBm až -50 dBm","cmc":"4,2 %"},{"name":"1270 nm až 1610 nm","range":"-50 dBm až -40 dBm","cmc":"2,7 %"},{"name":"1270 nm až 1610 nm","range":"-40 dBm až +10 dBm","cmc":"2,5 %"},{"name":"1625 nm až 1650 nm","range":"-60 dBm až -50 dBm","cmc":"4,6 %"},{"name":"1625 nm až 1650 nm","range":"-50 dBm až -40 dBm","cmc":"3,2 %"},{"name":"1625 nm až 1650 nm","range":"-40 dBm až +10 dBm","cmc":"3,0 %"}],"technique":"Porównanie pomiaru mocy promieniowania optycznego we włóknie detektorem miernika mocy optycznej z wzorcowym miernikiem mocy optycznej metodą porównawczą","technique_en":"Comparison of measurement of optical radiation in fibre by an optical power meter detector with a standard optical power meter using a comparative method","technique_zh":"用比较法将光功率计探测器对光纤中光辐射功率的测量与标准光功率计比较","technique_cs":"Porovnání měření výkonu optického záření ve vláknu detektorem měřidla optického výkonu s etalonovým měřidlem optického výkonu komparační metodou","techniques":["Porównanie pomiaru mocy promieniowania optycznego we włóknie detektorem miernika mocy optycznej z wzorcowym miernikiem mocy optycznej metodą porównawczą"],"techniques_en":["Comparison of measurement of optical radiation in fibre by an optical power meter detector with a standard optical power meter using a comparative method"],"techniques_zh":["用比较法将光功率计探测器对光纤中光辐射功率的测量与标准光功率计比较"],"techniques_cs":["Porovnání měření výkonu optického záření ve vláknu detektorem měřidla optického výkonu s etalonovým měřidlem optického výkonu komparační metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\n635 nm do 980 nm od -60 dBm do -50 dBm CMC 4,5 %\n635 nm do 980 nm od -50 dBm do -40 dBm CMC 3,2 %\n635 nm do 980 nm od -40 dBm do +10 dBm CMC 3,0 %\n1270 nm do 1610 nm od -60 dBm do -50 dBm CMC 4,2 %\n1270 nm do 1610 nm od -50 dBm do -40 dBm CMC 2,7 %\n1270 nm do 1610 nm od -40 dBm do +10 dBm CMC 2,5 %\n1625 nm do 1650 nm od -60 dBm do -50 dBm CMC 4,6 %\n1625 nm do 1650 nm od -50 dBm do -40 dBm CMC 3,2 %\n1625 nm do 1650 nm od -40 dBm do +10 dBm CMC 3,0 %\nPorównanie pomiaru mocy promieniowania optycznego we włóknie detektorem miernika mocy optycznej z wzorcowym miernikiem mocy optycznej metodą porównawczą","reference":"PPKL 2.1 (ČSN EN 61315 ed. 3)","norm_bases":["PPKL 2.1","ČSN EN 61315 ed. 3"],"lab_section":"OPTOKON Malezja","lab_section_en":"OPTOKON Malaysia","lab_section_zh":"OPTOKON 马来西亚","lab_section_cs":"OPTOKON Malaysia","lab_address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 11900 Bayan Lepas, Penang, MALAYSIA","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc optyczna / mierniki mocy optycznej Wzorcowanie – wielkości optyczne Porównanie pomiaru mocy promieniowania optycznego we włóknie detektorem miernika mocy optycznej z wzorcowym miernikiem mocy optycznej metodą porównawczą 635 nm do 980 nm od -60 dBm do -50 dBm CMC 4,5 % 635 nm do 980 nm od -50 dBm do -40 dBm CMC 3,2 % 635 nm do 980 nm od -40 dBm do +10 dBm CMC 3,0 % 1270 nm do 1610 nm od -60 dBm do -50 dBm CMC 4,2 % 1270 nm do 1610 nm od -50 dBm do -40 dBm CMC 2,7 % 1270 nm do 1610 nm od -40 dBm do +10 dBm CMC 2,5 % 1625 nm do 1650 nm od -60 dBm do -50 dBm CMC 4,6 % 1625 nm do 1650 nm od -50 dBm do -40 dBm CMC 3,2 % 1625 nm do 1650 nm od -40 dBm do +10 dBm CMC 3,0 % Optický výkon / měřidla optického výkonu Kalibrace – optické veličiny Porovnání měření výkonu optického záření ve vláknu detektorem měřidla optického výkonu s etalonovým měřidlem optického výkonu komparační metodou 635 nm až 980 nm -60 dBm až -50 dBm CMC 4,5 % 635 nm až 980 nm -50 dBm až -40 dBm CMC 3,2 % 635 nm až 980 nm -40 dBm až +10 dBm CMC 3,0 % 1270 nm až 1610 nm -60 dBm až -50 dBm CMC 4,2 % 1270 nm až 1610 nm -50 dBm až -40 dBm CMC 2,7 % 1270 nm až 1610 nm -40 dBm až +10 dBm CMC 2,5 % 1625 nm až 1650 nm -60 dBm až -50 dBm CMC 4,6 % 1625 nm až 1650 nm -50 dBm až -40 dBm CMC 3,2 % 1625 nm až 1650 nm -40 dBm až +10 dBm CMC 3,0 % PPKL 2.1 (ČSN EN 61315 ed. 3) Moc optyczna / mierniki mocy optycznej Wzorcowanie – wielkosci optyczne Porownanie pomiaru mocy promieniowania optycznego we wloknie detektorem miernika mocy optycznej z wzorcowym miernikiem mocy optycznej metoda porownawcza 635 nm do 980 nm od -60 dBm do -50 dBm CMC 4,5 % 635 nm do 980 nm od -50 dBm do -40 dBm CMC 3,2 % 635 nm do 980 nm od -40 dBm do +10 dBm CMC 3,0 % 1270 nm do 1610 nm od -60 dBm do -50 dBm CMC 4,2 % 1270 nm do 1610 nm od -50 dBm do -40 dBm CMC 2,7 % 1270 nm do 1610 nm od -40 dBm do +10 dBm CMC 2,5 % 1625 nm do 1650 nm od -60 dBm do -50 dBm CMC 4,6 % 1625 nm do 1650 nm od -50 dBm do -40 dBm CMC 3,2 % 1625 nm do 1650 nm od -40 dBm do +10 dBm CMC 3,0 % Opticky vykon / meridla optickeho vykonu Kalibrace – opticke veliciny Porovnani mereni vykonu optickeho zareni ve vlaknu detektorem meridla optickeho vykonu s etalonovym meridlem optickeho vykonu komparacni metodou 635 nm az 980 nm -60 dBm az -50 dBm CMC 4,5 % 635 nm az 980 nm -50 dBm az -40 dBm CMC 3,2 % 635 nm az 980 nm -40 dBm az +10 dBm CMC 3,0 % 1270 nm az 1610 nm -60 dBm az -50 dBm CMC 4,2 % 1270 nm az 1610 nm -50 dBm az -40 dBm CMC 2,7 % 1270 nm az 1610 nm -40 dBm az +10 dBm CMC 2,5 % 1625 nm az 1650 nm -60 dBm az -50 dBm CMC 4,6 % 1625 nm az 1650 nm -50 dBm az -40 dBm CMC 3,2 % 1625 nm az 1650 nm -40 dBm az +10 dBm CMC 3,0 % PPKL 2.1 (CSN EN 61315 ed. 3)","search_en":"Optical power / optical power meters Calibration – optical quantities Comparison of measurement of optical radiation in fibre by an optical power meter detector with a standard optical power meter using a comparative method OPTOKON Malaysia CMC for the field of measured quantity: Optical quantities Comparison of measurement of optical radiation in fibre by an optical power meter detector with a standard optical power meter using a comparative method 635 nm to 980 nm 635 nm to 980 nm 635 nm to 980 nm 1270 nm to 1610 nm 1270 nm to 1610 nm 1270 nm to 1610 nm 1625 nm to 1650 nm 1625 nm to 1650 nm 1625 nm to 1650 nm PPKL 2.1 (ČSN EN 61315 ed. 3)","search_zh":"光功率 / 光功率计 校准 – 光学量 用比较法将光功率计探测器对光纤中光辐射功率的测量与标准光功率计比较 OPTOKON 马来西亚 被测量领域的CMC：光学量 用比较法将光功率计探测器对光纤中光辐射功率的测量与标准光功率计比较 635 nm 至 980 nm 635 nm 至 980 nm 635 nm 至 980 nm 1270 nm 至 1610 nm 1270 nm 至 1610 nm 1270 nm 至 1610 nm 1625 nm 至 1650 nm 1625 nm 至 1650 nm 1625 nm 至 1650 nm PPKL 2.1 (ČSN EN 61315 第3版)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Malaysia","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"635 nm bis 980 nm","range":"von -60 dBm bis -50 dBm","cmc":"4,5 %"},{"name":"635 nm bis 980 nm","range":"von -50 dBm bis -40 dBm","cmc":"3,2 %"},{"name":"635 nm bis 980 nm","range":"von -40 dBm bis +10 dBm","cmc":"3,0 %"},{"name":"1270 nm bis 1610 nm","range":"von -60 dBm bis -50 dBm","cmc":"4,2 %"},{"name":"1270 nm bis 1610 nm","range":"von -50 dBm bis -40 dBm","cmc":"2,7 %"},{"name":"1270 nm bis 1610 nm","range":"von -40 dBm bis +10 dBm","cmc":"2,5 %"},{"name":"1625 nm bis 1650 nm","range":"von -60 dBm bis -50 dBm","cmc":"4,6 %"},{"name":"1625 nm bis 1650 nm","range":"von -50 dBm bis -40 dBm","cmc":"3,2 %"},{"name":"1625 nm bis 1650 nm","range":"von -40 dBm bis +10 dBm","cmc":"3,0 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Leistung / optische Leistungsmessgeräte Kalibrierung – optische Größen Vergleich der Messung der optischen Strahlungsleistung im Lichtwellenleiter mit dem Detektor des optischen Leistungsmessers mit einem optischen Referenz-Leistungsmesser im Vergleichsverfahren OPTOKON Malaysia CMC für den Messgrößenbereich: optische Größen Vergleich der Messung der optischen Strahlungsleistung im Lichtwellenleiter mit dem Detektor des optischen Leistungsmessers mit einem optischen Referenz-Leistungsmesser im Vergleichsverfahren 635 nm bis 980 nm 635 nm bis 980 nm 635 nm bis 980 nm 1270 nm bis 1610 nm 1270 nm bis 1610 nm 1270 nm bis 1610 nm 1625 nm bis 1650 nm 1625 nm bis 1650 nm 1625 nm bis 1650 nm PPKL 2.1 (ČSN EN 61315 Ausg. 3)","technique_de":"Vergleich der Messung der optischen Strahlungsleistung im Lichtwellenleiter mit dem Detektor des optischen Leistungsmessers mit einem optischen Referenz-Leistungsmesser im Vergleichsverfahren","techniques_de":["Vergleich der Messung der optischen Strahlungsleistung im Lichtwellenleiter mit dem Detektor des optischen Leistungsmessers mit einem optischen Referenz-Leistungsmesser im Vergleichsverfahren"],"test_object_de":"Optische Leistung / optische Leistungsmessgeräte","reference_de":"PPKL 2.1 (ČSN EN 61315 Ausg. 3)","reference_zh":"PPKL 2.1 (ČSN EN 61315 第3版)","reference_pl":"PPKL 2.1 (ČSN EN 61315 wyd. 3)"},{"_id":"cad1c8a06068bf35aa709577","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"2","test_object":"Tłumienie optyczne / tłumik optyczny","test_object_en":"Optical attenuation / optical attenuator","test_object_zh":"光衰减 / 光衰减器","test_object_cs":"Optický útlum / optický atenuátor","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1270 nm do 1650 nm","range":"od 0 dB do 40 dB","cmc":"0,26 dB"},{"name":"1270 nm do 1650 nm","range":"od 40 dB do 65 dB","cmc":"0,30 dB"}],"parameters_en":[{"name":"1270 nm to 1650 nm","range":"0 dB to 40 dB","cmc":"0,26 dB"},{"name":"1270 nm to 1650 nm","range":"40 dB to 65 dB","cmc":"0,30 dB"}],"parameters_zh":[{"name":"1270 nm 至 1650 nm","range":"0 dB 至 40 dB","cmc":"0,26 dB"},{"name":"1270 nm 至 1650 nm","range":"40 dB 至 65 dB","cmc":"0,30 dB"}],"parameters_cs":[{"name":"1270 nm až 1650 nm","range":"0 dB až 40 dB","cmc":"0,26 dB"},{"name":"1270 nm až 1650 nm","range":"40 dB až 65 dB","cmc":"0,30 dB"}],"technique":"Pomiar tłumienia wtrąceniowego dla poszczególnych nastaw tłumika","technique_en":"Measurement of insertion loss for individual settings of an attenuator","technique_zh":"测量衰减器各设置的插入损耗","technique_cs":"Měření vložného útlumu pro jednotlivá nastavení atenuátoru","techniques":["Pomiar tłumienia wtrąceniowego dla poszczególnych nastaw tłumika"],"techniques_en":["Measurement of insertion loss for individual settings of an attenuator"],"techniques_zh":["测量衰减器各设置的插入损耗"],"techniques_cs":["Měření vložného útlumu pro jednotlivá nastavení atenuátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\n1270 nm do 1650 nm od 0 dB do 40 dB CMC 0,26 dB\n1270 nm do 1650 nm od 40 dB do 65 dB CMC 0,30 dB\nPomiar tłumienia wtrąceniowego dla poszczególnych nastaw tłumika","reference":"PPKL 2.2 (ČSN EN 61300-3-4 ed. 2)","norm_bases":["PPKL 2.2","ČSN EN 61300-3-4 ed. 2"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłumienie optyczne / tłumik optyczny Wzorcowanie – wielkości optyczne Pomiar tłumienia wtrąceniowego dla poszczególnych nastaw tłumika 1270 nm do 1650 nm od 0 dB do 40 dB CMC 0,26 dB 1270 nm do 1650 nm od 40 dB do 65 dB CMC 0,30 dB Optický útlum / optický atenuátor Kalibrace – optické veličiny Měření vložného útlumu pro jednotlivá nastavení atenuátoru 1270 nm až 1650 nm 0 dB až 40 dB CMC 0,26 dB 1270 nm až 1650 nm 40 dB až 65 dB CMC 0,30 dB PPKL 2.2 (ČSN EN 61300-3-4 ed. 2) Tlumienie optyczne / tlumik optyczny Wzorcowanie – wielkosci optyczne Pomiar tlumienia wtraceniowego dla poszczegolnych nastaw tlumika 1270 nm do 1650 nm od 0 dB do 40 dB CMC 0,26 dB 1270 nm do 1650 nm od 40 dB do 65 dB CMC 0,30 dB Opticky utlum / opticky atenuator Kalibrace – opticke veliciny Mereni vlozneho utlumu pro jednotliva nastaveni atenuatoru 1270 nm az 1650 nm 0 dB az 40 dB CMC 0,26 dB 1270 nm az 1650 nm 40 dB az 65 dB CMC 0,30 dB PPKL 2.2 (CSN EN 61300-3-4 ed. 2)","search_en":"Optical attenuation / optical attenuator Calibration – optical quantities Measurement of insertion loss for individual settings of an attenuator OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities Measurement of insertion loss for individual settings of an attenuator 1270 nm to 1650 nm 1270 nm to 1650 nm PPKL 2.2 (ČSN EN 61300-3-4 ed. 2)","search_zh":"光衰减 / 光衰减器 校准 – 光学量 测量衰减器各设置的插入损耗 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 测量衰减器各设置的插入损耗 1270 nm 至 1650 nm 1270 nm 至 1650 nm PPKL 2.2 (ČSN EN 61300-3-4 第2版)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1270 nm bis 1650 nm","range":"von 0 dB bis 40 dB","cmc":"0,26 dB"},{"name":"1270 nm bis 1650 nm","range":"von 40 dB bis 65 dB","cmc":"0,30 dB"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Dämpfung / optisches Dämpfungsglied Kalibrierung – optische Größen Messung der Einfügedämpfung für die einzelnen Dämpfungsgliedeinstellungen OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen Messung der Einfügedämpfung für die einzelnen Dämpfungsgliedeinstellungen 1270 nm bis 1650 nm 1270 nm bis 1650 nm PPKL 2.2 (ČSN EN 61300-3-4 Ausg. 2)","technique_de":"Messung der Einfügedämpfung für die einzelnen Dämpfungsgliedeinstellungen","techniques_de":["Messung der Einfügedämpfung für die einzelnen Dämpfungsgliedeinstellungen"],"test_object_de":"Optische Dämpfung / optisches Dämpfungsglied","reference_de":"PPKL 2.2 (ČSN EN 61300-3-4 Ausg. 2)","reference_zh":"PPKL 2.2 (ČSN EN 61300-3-4 第2版)","reference_pl":"PPKL 2.2 (ČSN EN 61300-3-4 wyd. 2)"},{"_id":"1818d3a08c808d9aa2b6d7cd","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"2","test_object":"Tłumienie optyczne / tłumik optyczny","test_object_en":"Optical attenuation / optical attenuator","test_object_zh":"光衰减 / 光衰减器","test_object_cs":"Optický útlum / optický atenuátor","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1270 nm do 1650 nm","range":"od 0 dB do 40 dB","cmc":"0,26 dB"},{"name":"1270 nm do 1650 nm","range":"od 40 dB do 65 dB","cmc":"0,30 dB"}],"parameters_en":[{"name":"1270 nm to 1650 nm","range":"0 dB to 40 dB","cmc":"0,26 dB"},{"name":"1270 nm to 1650 nm","range":"40 dB to 65 dB","cmc":"0,30 dB"}],"parameters_zh":[{"name":"1270 nm 至 1650 nm","range":"0 dB 至 40 dB","cmc":"0,26 dB"},{"name":"1270 nm 至 1650 nm","range":"40 dB 至 65 dB","cmc":"0,30 dB"}],"parameters_cs":[{"name":"1270 nm až 1650 nm","range":"0 dB až 40 dB","cmc":"0,26 dB"},{"name":"1270 nm až 1650 nm","range":"40 dB až 65 dB","cmc":"0,30 dB"}],"technique":"Pomiar tłumienia wtrąceniowego dla poszczególnych nastaw tłumika","technique_en":"Measurement of insertion loss for individual settings of an attenuator","technique_zh":"测量衰减器各设置的插入损耗","technique_cs":"Měření vložného útlumu pro jednotlivá nastavení atenuátoru","techniques":["Pomiar tłumienia wtrąceniowego dla poszczególnych nastaw tłumika"],"techniques_en":["Measurement of insertion loss for individual settings of an attenuator"],"techniques_zh":["测量衰减器各设置的插入损耗"],"techniques_cs":["Měření vložného útlumu pro jednotlivá nastavení atenuátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\n1270 nm do 1650 nm od 0 dB do 40 dB CMC 0,26 dB\n1270 nm do 1650 nm od 40 dB do 65 dB CMC 0,30 dB\nPomiar tłumienia wtrąceniowego dla poszczególnych nastaw tłumika","reference":"PPKL 2.2 (ČSN EN 61300-3-4 ed. 2)","norm_bases":["PPKL 2.2","ČSN EN 61300-3-4 ed. 2"],"lab_section":"OPTOKON Malezja","lab_section_en":"OPTOKON Malaysia","lab_section_zh":"OPTOKON 马来西亚","lab_section_cs":"OPTOKON Malaysia","lab_address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 11900 Bayan Lepas, Penang, MALAYSIA","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłumienie optyczne / tłumik optyczny Wzorcowanie – wielkości optyczne Pomiar tłumienia wtrąceniowego dla poszczególnych nastaw tłumika 1270 nm do 1650 nm od 0 dB do 40 dB CMC 0,26 dB 1270 nm do 1650 nm od 40 dB do 65 dB CMC 0,30 dB Optický útlum / optický atenuátor Kalibrace – optické veličiny Měření vložného útlumu pro jednotlivá nastavení atenuátoru 1270 nm až 1650 nm 0 dB až 40 dB CMC 0,26 dB 1270 nm až 1650 nm 40 dB až 65 dB CMC 0,30 dB PPKL 2.2 (ČSN EN 61300-3-4 ed. 2) Tlumienie optyczne / tlumik optyczny Wzorcowanie – wielkosci optyczne Pomiar tlumienia wtraceniowego dla poszczegolnych nastaw tlumika 1270 nm do 1650 nm od 0 dB do 40 dB CMC 0,26 dB 1270 nm do 1650 nm od 40 dB do 65 dB CMC 0,30 dB Opticky utlum / opticky atenuator Kalibrace – opticke veliciny Mereni vlozneho utlumu pro jednotliva nastaveni atenuatoru 1270 nm az 1650 nm 0 dB az 40 dB CMC 0,26 dB 1270 nm az 1650 nm 40 dB az 65 dB CMC 0,30 dB PPKL 2.2 (CSN EN 61300-3-4 ed. 2)","search_en":"Optical attenuation / optical attenuator Calibration – optical quantities Measurement of insertion loss for individual settings of an attenuator OPTOKON Malaysia CMC for the field of measured quantity: Optical quantities Measurement of insertion loss for individual settings of an attenuator 1270 nm to 1650 nm 1270 nm to 1650 nm PPKL 2.2 (ČSN EN 61300-3-4 ed. 2)","search_zh":"光衰减 / 光衰减器 校准 – 光学量 测量衰减器各设置的插入损耗 OPTOKON 马来西亚 被测量领域的CMC：光学量 测量衰减器各设置的插入损耗 1270 nm 至 1650 nm 1270 nm 至 1650 nm PPKL 2.2 (ČSN EN 61300-3-4 第2版)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Malaysia","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1270 nm bis 1650 nm","range":"von 0 dB bis 40 dB","cmc":"0,26 dB"},{"name":"1270 nm bis 1650 nm","range":"von 40 dB bis 65 dB","cmc":"0,30 dB"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Dämpfung / optisches Dämpfungsglied Kalibrierung – optische Größen Messung der Einfügedämpfung für die einzelnen Dämpfungsgliedeinstellungen OPTOKON Malaysia CMC für den Messgrößenbereich: optische Größen Messung der Einfügedämpfung für die einzelnen Dämpfungsgliedeinstellungen 1270 nm bis 1650 nm 1270 nm bis 1650 nm PPKL 2.2 (ČSN EN 61300-3-4 Ausg. 2)","technique_de":"Messung der Einfügedämpfung für die einzelnen Dämpfungsgliedeinstellungen","techniques_de":["Messung der Einfügedämpfung für die einzelnen Dämpfungsgliedeinstellungen"],"test_object_de":"Optische Dämpfung / optisches Dämpfungsglied","reference_de":"PPKL 2.2 (ČSN EN 61300-3-4 Ausg. 2)","reference_zh":"PPKL 2.2 (ČSN EN 61300-3-4 第2版)","reference_pl":"PPKL 2.2 (ČSN EN 61300-3-4 wyd. 2)"},{"_id":"97144140b97842883a7136c0","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"3","test_object":"Długość fali / źródło promieniowania optycznego do światłowodów","test_object_en":"Wavelength / optical source for fibre optics","test_object_zh":"波长 / 光纤用光源","test_object_cs":"Vlnová délka / zdroj optického záření pro vláknovou optiku","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"średnia długość fali","range":"od 600 nm do 1700 nm","cmc":"0,33 nm"},{"name":"maksimum natężenia","range":"od 600 nm do 1700 nm","cmc":"0,33 nm"}],"parameters_en":[{"name":"medium wavelength","range":"600 nm to 1700 nm","cmc":"0,33 nm"},{"name":"maximum intensity","range":"600 nm to 1700 nm","cmc":"0,33 nm"}],"parameters_zh":[{"name":"中心波长","range":"600 nm 至 1700 nm","cmc":"0,33 nm"},{"name":"最大强度","range":"600 nm 至 1700 nm","cmc":"0,33 nm"}],"parameters_cs":[{"name":"střední vlnová délka","range":"600 nm až 1700 nm","cmc":"0,33 nm"},{"name":"maximální intenzity","range":"600 nm až 1700 nm","cmc":"0,33 nm"}],"technique":"Pomiar długości fali promieniowania optycznego we włóknie optycznym analizatorem widma (OSA)","technique_en":"Measurement of wavelength of optical radiation in fibre by an optical spectral analyser (OSA)","technique_zh":"用光谱分析仪（OSA）测量光纤中光辐射的波长","technique_cs":"Měření vlnové délky optického záření ve vláknu optickým spektrálním analyzátorem (OSA)","techniques":["Pomiar długości fali promieniowania optycznego we włóknie optycznym analizatorem widma (OSA)"],"techniques_en":["Measurement of wavelength of optical radiation in fibre by an optical spectral analyser (OSA)"],"techniques_zh":["用光谱分析仪（OSA）测量光纤中光辐射的波长"],"techniques_cs":["Měření vlnové délky optického záření ve vláknu optickým spektrálním analyzátorem (OSA)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\nśrednia długość fali od 600 nm do 1700 nm CMC 0,33 nm\nmaksimum natężenia od 600 nm do 1700 nm CMC 0,33 nm\nPomiar długości fali promieniowania optycznego we włóknie optycznym analizatorem widma (OSA)","reference":"PPKL 2.3 (ČSN EN 61315 ed. 3)","norm_bases":["PPKL 2.3","ČSN EN 61315 ed. 3"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długość fali / źródło promieniowania optycznego do światłowodów Wzorcowanie – wielkości optyczne Pomiar długości fali promieniowania optycznego we włóknie optycznym analizatorem widma (OSA) średnia długość fali od 600 nm do 1700 nm CMC 0,33 nm maksimum natężenia od 600 nm do 1700 nm CMC 0,33 nm Vlnová délka / zdroj optického záření pro vláknovou optiku Kalibrace – optické veličiny Měření vlnové délky optického záření ve vláknu optickým spektrálním analyzátorem (OSA) střední vlnová délka 600 nm až 1700 nm CMC 0,33 nm maximální intenzity 600 nm až 1700 nm CMC 0,33 nm PPKL 2.3 (ČSN EN 61315 ed. 3) Dlugosc fali / zrodlo promieniowania optycznego do swiatlowodow Wzorcowanie – wielkosci optyczne Pomiar dlugosci fali promieniowania optycznego we wloknie optycznym analizatorem widma (OSA) srednia dlugosc fali od 600 nm do 1700 nm CMC 0,33 nm maksimum natezenia od 600 nm do 1700 nm CMC 0,33 nm Vlnova delka / zdroj optickeho zareni pro vlaknovou optiku Kalibrace – opticke veliciny Mereni vlnove delky optickeho zareni ve vlaknu optickym spektralnim analyzatorem (OSA) stredni vlnova delka 600 nm az 1700 nm CMC 0,33 nm maximalni intenzity 600 nm az 1700 nm CMC 0,33 nm PPKL 2.3 (CSN EN 61315 ed. 3)","search_en":"Wavelength / optical source for fibre optics Calibration – optical quantities Measurement of wavelength of optical radiation in fibre by an optical spectral analyser (OSA) OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities Measurement of wavelength of optical radiation in fibre by an optical spectral analyser (OSA) medium wavelength maximum intensity PPKL 2.3 (ČSN EN 61315 ed. 3)","search_zh":"波长 / 光纤用光源 校准 – 光学量 用光谱分析仪（OSA）测量光纤中光辐射的波长 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 用光谱分析仪（OSA）测量光纤中光辐射的波长 中心波长 最大强度 PPKL 2.3 (ČSN EN 61315 第3版)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"mittlere Wellenlänge","range":"von 600 nm bis 1700 nm","cmc":"0,33 nm"},{"name":"Intensitätsmaximum","range":"von 600 nm bis 1700 nm","cmc":"0,33 nm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Wellenlänge / optische Strahlungsquelle für Lichtwellenleiter Kalibrierung – optische Größen Messung der Wellenlänge optischer Strahlung in Lichtwellenleitern mit Spektrumanalysator (OSA) OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen Messung der Wellenlänge optischer Strahlung in Lichtwellenleitern mit Spektrumanalysator (OSA) mittlere Wellenlänge Intensitätsmaximum PPKL 2.3 (ČSN EN 61315 Ausg. 3)","technique_de":"Messung der Wellenlänge optischer Strahlung in Lichtwellenleitern mit Spektrumanalysator (OSA)","techniques_de":["Messung der Wellenlänge optischer Strahlung in Lichtwellenleitern mit Spektrumanalysator (OSA)"],"test_object_de":"Wellenlänge / optische Strahlungsquelle für Lichtwellenleiter","reference_de":"PPKL 2.3 (ČSN EN 61315 Ausg. 3)","reference_zh":"PPKL 2.3 (ČSN EN 61315 第3版)","reference_pl":"PPKL 2.3 (ČSN EN 61315 wyd. 3)"},{"_id":"94ef59a8d112e8048374fc11","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"3","test_object":"Długość fali / źródło promieniowania optycznego do światłowodów","test_object_en":"Wavelength / optical source for fibre optics","test_object_zh":"波长 / 光纤用光源","test_object_cs":"Vlnová délka / zdroj optického záření pro vláknovou optiku","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"średnia długość fali","range":"od 600 nm do 1700 nm","cmc":"0,33 nm"},{"name":"maksimum natężenia","range":"od 600 nm do 1700 nm","cmc":"0,33 nm"}],"parameters_en":[{"name":"medium wavelength","range":"600 nm to 1700 nm","cmc":"0,33 nm"},{"name":"maximum intensity","range":"600 nm to 1700 nm","cmc":"0,33 nm"}],"parameters_zh":[{"name":"中心波长","range":"600 nm 至 1700 nm","cmc":"0,33 nm"},{"name":"最大强度","range":"600 nm 至 1700 nm","cmc":"0,33 nm"}],"parameters_cs":[{"name":"střední vlnová délka","range":"600 nm až 1700 nm","cmc":"0,33 nm"},{"name":"maximální intenzity","range":"600 nm až 1700 nm","cmc":"0,33 nm"}],"technique":"Pomiar długości fali promieniowania optycznego we włóknie optycznym analizatorem widma (OSA)","technique_en":"Measurement of wavelength of optical radiation in fibre by an optical spectral analyser (OSA)","technique_zh":"用光谱分析仪（OSA）测量光纤中光辐射的波长","technique_cs":"Měření vlnové délky optického záření ve vláknu optickým spektrálním analyzátorem (OSA)","techniques":["Pomiar długości fali promieniowania optycznego we włóknie optycznym analizatorem widma (OSA)"],"techniques_en":["Measurement of wavelength of optical radiation in fibre by an optical spectral analyser (OSA)"],"techniques_zh":["用光谱分析仪（OSA）测量光纤中光辐射的波长"],"techniques_cs":["Měření vlnové délky optického záření ve vláknu optickým spektrálním analyzátorem (OSA)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\nśrednia długość fali od 600 nm do 1700 nm CMC 0,33 nm\nmaksimum natężenia od 600 nm do 1700 nm CMC 0,33 nm\nPomiar długości fali promieniowania optycznego we włóknie optycznym analizatorem widma (OSA)","reference":"PPKL 2.3 (ČSN EN 61315 ed. 3)","norm_bases":["PPKL 2.3","ČSN EN 61315 ed. 3"],"lab_section":"OPTOKON Malezja","lab_section_en":"OPTOKON Malaysia","lab_section_zh":"OPTOKON 马来西亚","lab_section_cs":"OPTOKON Malaysia","lab_address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 11900 Bayan Lepas, Penang, MALAYSIA","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długość fali / źródło promieniowania optycznego do światłowodów Wzorcowanie – wielkości optyczne Pomiar długości fali promieniowania optycznego we włóknie optycznym analizatorem widma (OSA) średnia długość fali od 600 nm do 1700 nm CMC 0,33 nm maksimum natężenia od 600 nm do 1700 nm CMC 0,33 nm Vlnová délka / zdroj optického záření pro vláknovou optiku Kalibrace – optické veličiny Měření vlnové délky optického záření ve vláknu optickým spektrálním analyzátorem (OSA) střední vlnová délka 600 nm až 1700 nm CMC 0,33 nm maximální intenzity 600 nm až 1700 nm CMC 0,33 nm PPKL 2.3 (ČSN EN 61315 ed. 3) Dlugosc fali / zrodlo promieniowania optycznego do swiatlowodow Wzorcowanie – wielkosci optyczne Pomiar dlugosci fali promieniowania optycznego we wloknie optycznym analizatorem widma (OSA) srednia dlugosc fali od 600 nm do 1700 nm CMC 0,33 nm maksimum natezenia od 600 nm do 1700 nm CMC 0,33 nm Vlnova delka / zdroj optickeho zareni pro vlaknovou optiku Kalibrace – opticke veliciny Mereni vlnove delky optickeho zareni ve vlaknu optickym spektralnim analyzatorem (OSA) stredni vlnova delka 600 nm az 1700 nm CMC 0,33 nm maximalni intenzity 600 nm az 1700 nm CMC 0,33 nm PPKL 2.3 (CSN EN 61315 ed. 3)","search_en":"Wavelength / optical source for fibre optics Calibration – optical quantities Measurement of wavelength of optical radiation in fibre by an optical spectral analyser (OSA) OPTOKON Malaysia CMC for the field of measured quantity: Optical quantities Measurement of wavelength of optical radiation in fibre by an optical spectral analyser (OSA) medium wavelength maximum intensity PPKL 2.3 (ČSN EN 61315 ed. 3)","search_zh":"波长 / 光纤用光源 校准 – 光学量 用光谱分析仪（OSA）测量光纤中光辐射的波长 OPTOKON 马来西亚 被测量领域的CMC：光学量 用光谱分析仪（OSA）测量光纤中光辐射的波长 中心波长 最大强度 PPKL 2.3 (ČSN EN 61315 第3版)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Malaysia","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"mittlere Wellenlänge","range":"von 600 nm bis 1700 nm","cmc":"0,33 nm"},{"name":"Intensitätsmaximum","range":"von 600 nm bis 1700 nm","cmc":"0,33 nm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Wellenlänge / optische Strahlungsquelle für Lichtwellenleiter Kalibrierung – optische Größen Messung der Wellenlänge optischer Strahlung in Lichtwellenleitern mit Spektrumanalysator (OSA) OPTOKON Malaysia CMC für den Messgrößenbereich: optische Größen Messung der Wellenlänge optischer Strahlung in Lichtwellenleitern mit Spektrumanalysator (OSA) mittlere Wellenlänge Intensitätsmaximum PPKL 2.3 (ČSN EN 61315 Ausg. 3)","technique_de":"Messung der Wellenlänge optischer Strahlung in Lichtwellenleitern mit Spektrumanalysator (OSA)","techniques_de":["Messung der Wellenlänge optischer Strahlung in Lichtwellenleitern mit Spektrumanalysator (OSA)"],"test_object_de":"Wellenlänge / optische Strahlungsquelle für Lichtwellenleiter","reference_de":"PPKL 2.3 (ČSN EN 61315 Ausg. 3)","reference_zh":"PPKL 2.3 (ČSN EN 61315 第3版)","reference_pl":"PPKL 2.3 (ČSN EN 61315 wyd. 3)"},{"_id":"b6d256e15bfa3c87d85c2ba5","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"4","test_object":"Tłumienie odbiciowe / miernik tłumienia odbiciowego","test_object_en":"Optical return loss / optical return loss meter","test_object_zh":"光回波损耗 / 光回波损耗测量仪","test_object_cs":"Optický útlum odrazu / měřidlo optického útlumu odrazu","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1000 nm do 1700 nm","range":"od 3 dB do 32 dB","cmc":"0,5 dB"},{"name":"1000 nm do 1700 nm","range":"od 32 dB do 42 dB","cmc":"0,7 dB"},{"name":"1000 nm do 1700 nm","range":"od 42 dB do 52 dB","cmc":"1,0 dB"},{"name":"1000 nm do 1700 nm","range":"od 52 dB do 61 dB","cmc":"1,5 dB"}],"parameters_en":[{"name":"1000 nm to 1700 nm","range":"3 dB to 32 dB","cmc":"0,5 dB"},{"name":"1000 nm to 1700 nm","range":"32 dB to 42 dB","cmc":"0,7 dB"},{"name":"1000 nm to 1700 nm","range":"42 dB to 52 dB","cmc":"1,0 dB"},{"name":"1000 nm to 1700 nm","range":"52 dB to 61 dB","cmc":"1,5 dB"}],"parameters_zh":[{"name":"1000 nm 至 1700 nm","range":"3 dB 至 32 dB","cmc":"0,5 dB"},{"name":"1000 nm 至 1700 nm","range":"32 dB 至 42 dB","cmc":"0,7 dB"},{"name":"1000 nm 至 1700 nm","range":"42 dB 至 52 dB","cmc":"1,0 dB"},{"name":"1000 nm 至 1700 nm","range":"52 dB 至 61 dB","cmc":"1,5 dB"}],"parameters_cs":[{"name":"1000 nm až 1700 nm","range":"3 dB až 32 dB","cmc":"0,5 dB"},{"name":"1000 nm až 1700 nm","range":"32 dB až 42 dB","cmc":"0,7 dB"},{"name":"1000 nm až 1700 nm","range":"42 dB až 52 dB","cmc":"1,0 dB"},{"name":"1000 nm až 1700 nm","range":"52 dB až 61 dB","cmc":"1,5 dB"}],"technique":"Pomiar tłumienia odbiciowego i porównanie z wartością odniesienia","technique_en":"Measurement of optical return loss and comparison with a reference value","technique_zh":"测量光回波损耗并与参考值比较","technique_cs":"Měření optického útlumu odrazu a porovnání s referenční hodnotou","techniques":["Pomiar tłumienia odbiciowego i porównanie z wartością odniesienia"],"techniques_en":["Measurement of optical return loss and comparison with a reference value"],"techniques_zh":["测量光回波损耗并与参考值比较"],"techniques_cs":["Měření optického útlumu odrazu a porovnání s referenční hodnotou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\n1000 nm do 1700 nm od 3 dB do 32 dB CMC 0,5 dB\n1000 nm do 1700 nm od 32 dB do 42 dB CMC 0,7 dB\n1000 nm do 1700 nm od 42 dB do 52 dB CMC 1,0 dB\n1000 nm do 1700 nm od 52 dB do 61 dB CMC 1,5 dB\nPomiar tłumienia odbiciowego i porównanie z wartością odniesienia","reference":"PPKL 2.4 (ČSN EN 61300-3-6 ed. 2)","norm_bases":["PPKL 2.4","ČSN EN 61300-3-6 ed. 2"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłumienie odbiciowe / miernik tłumienia odbiciowego Wzorcowanie – wielkości optyczne Pomiar tłumienia odbiciowego i porównanie z wartością odniesienia 1000 nm do 1700 nm od 3 dB do 32 dB CMC 0,5 dB 1000 nm do 1700 nm od 32 dB do 42 dB CMC 0,7 dB 1000 nm do 1700 nm od 42 dB do 52 dB CMC 1,0 dB 1000 nm do 1700 nm od 52 dB do 61 dB CMC 1,5 dB Optický útlum odrazu / měřidlo optického útlumu odrazu Kalibrace – optické veličiny Měření optického útlumu odrazu a porovnání s referenční hodnotou 1000 nm až 1700 nm 3 dB až 32 dB CMC 0,5 dB 1000 nm až 1700 nm 32 dB až 42 dB CMC 0,7 dB 1000 nm až 1700 nm 42 dB až 52 dB CMC 1,0 dB 1000 nm až 1700 nm 52 dB až 61 dB CMC 1,5 dB PPKL 2.4 (ČSN EN 61300-3-6 ed. 2) Tlumienie odbiciowe / miernik tlumienia odbiciowego Wzorcowanie – wielkosci optyczne Pomiar tlumienia odbiciowego i porownanie z wartoscia odniesienia 1000 nm do 1700 nm od 3 dB do 32 dB CMC 0,5 dB 1000 nm do 1700 nm od 32 dB do 42 dB CMC 0,7 dB 1000 nm do 1700 nm od 42 dB do 52 dB CMC 1,0 dB 1000 nm do 1700 nm od 52 dB do 61 dB CMC 1,5 dB Opticky utlum odrazu / meridlo optickeho utlumu odrazu Kalibrace – opticke veliciny Mereni optickeho utlumu odrazu a porovnani s referencni hodnotou 1000 nm az 1700 nm 3 dB az 32 dB CMC 0,5 dB 1000 nm az 1700 nm 32 dB az 42 dB CMC 0,7 dB 1000 nm az 1700 nm 42 dB az 52 dB CMC 1,0 dB 1000 nm az 1700 nm 52 dB az 61 dB CMC 1,5 dB PPKL 2.4 (CSN EN 61300-3-6 ed. 2)","search_en":"Optical return loss / optical return loss meter Calibration – optical quantities Measurement of optical return loss and comparison with a reference value OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities Measurement of optical return loss and comparison with a reference value 1000 nm to 1700 nm 1000 nm to 1700 nm 1000 nm to 1700 nm 1000 nm to 1700 nm PPKL 2.4 (ČSN EN 61300-3-6 ed. 2)","search_zh":"光回波损耗 / 光回波损耗测量仪 校准 – 光学量 测量光回波损耗并与参考值比较 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 测量光回波损耗并与参考值比较 1000 nm 至 1700 nm 1000 nm 至 1700 nm 1000 nm 至 1700 nm 1000 nm 至 1700 nm PPKL 2.4 (ČSN EN 61300-3-6 第2版)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1000 nm bis 1700 nm","range":"von 3 dB bis 32 dB","cmc":"0,5 dB"},{"name":"1000 nm bis 1700 nm","range":"von 32 dB bis 42 dB","cmc":"0,7 dB"},{"name":"1000 nm bis 1700 nm","range":"von 42 dB bis 52 dB","cmc":"1,0 dB"},{"name":"1000 nm bis 1700 nm","range":"von 52 dB bis 61 dB","cmc":"1,5 dB"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Rückflussdämpfung / Rückflussdämpfungsmessgerät Kalibrierung – optische Größen Messung der Rückflussdämpfung und Vergleich mit dem Referenzwert OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen Messung der Rückflussdämpfung und Vergleich mit dem Referenzwert 1000 nm bis 1700 nm 1000 nm bis 1700 nm 1000 nm bis 1700 nm 1000 nm bis 1700 nm PPKL 2.4 (ČSN EN 61300-3-6 Ausg. 2)","technique_de":"Messung der Rückflussdämpfung und Vergleich mit dem Referenzwert","techniques_de":["Messung der Rückflussdämpfung und Vergleich mit dem Referenzwert"],"test_object_de":"Rückflussdämpfung / Rückflussdämpfungsmessgerät","reference_de":"PPKL 2.4 (ČSN EN 61300-3-6 Ausg. 2)","reference_zh":"PPKL 2.4 (ČSN EN 61300-3-6 第2版)","reference_pl":"PPKL 2.4 (ČSN EN 61300-3-6 wyd. 2)"},{"_id":"fc03c178cfe60bf780ef3cf1","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"4","test_object":"Tłumienie odbiciowe / miernik tłumienia odbiciowego","test_object_en":"Optical return loss / optical return loss meter","test_object_zh":"光回波损耗 / 光回波损耗测量仪","test_object_cs":"Optický útlum odrazu / měřidlo optického útlumu odrazu","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1000 nm do 1700 nm","range":"od 3 dB do 32 dB","cmc":"0,5 dB"},{"name":"1000 nm do 1700 nm","range":"od 32 dB do 42 dB","cmc":"0,7 dB"},{"name":"1000 nm do 1700 nm","range":"od 42 dB do 52 dB","cmc":"1,0 dB"},{"name":"1000 nm do 1700 nm","range":"od 52 dB do 61 dB","cmc":"1,5 dB"}],"parameters_en":[{"name":"1000 nm to 1700 nm","range":"3 dB to 32 dB","cmc":"0,5 dB"},{"name":"1000 nm to 1700 nm","range":"32 dB to 42 dB","cmc":"0,7 dB"},{"name":"1000 nm to 1700 nm","range":"42 dB to 52 dB","cmc":"1,0 dB"},{"name":"1000 nm to 1700 nm","range":"52 dB to 61 dB","cmc":"1,5 dB"}],"parameters_zh":[{"name":"1000 nm 至 1700 nm","range":"3 dB 至 32 dB","cmc":"0,5 dB"},{"name":"1000 nm 至 1700 nm","range":"32 dB 至 42 dB","cmc":"0,7 dB"},{"name":"1000 nm 至 1700 nm","range":"42 dB 至 52 dB","cmc":"1,0 dB"},{"name":"1000 nm 至 1700 nm","range":"52 dB 至 61 dB","cmc":"1,5 dB"}],"parameters_cs":[{"name":"1000 nm až 1700 nm","range":"3 dB až 32 dB","cmc":"0,5 dB"},{"name":"1000 nm až 1700 nm","range":"32 dB až 42 dB","cmc":"0,7 dB"},{"name":"1000 nm až 1700 nm","range":"42 dB až 52 dB","cmc":"1,0 dB"},{"name":"1000 nm až 1700 nm","range":"52 dB až 61 dB","cmc":"1,5 dB"}],"technique":"Pomiar tłumienia odbiciowego i porównanie z wartością odniesienia","technique_en":"Measurement of optical return loss and comparison with a reference value","technique_zh":"测量光回波损耗并与参考值比较","technique_cs":"Měření optického útlumu odrazu a porovnání s referenční hodnotou","techniques":["Pomiar tłumienia odbiciowego i porównanie z wartością odniesienia"],"techniques_en":["Measurement of optical return loss and comparison with a reference value"],"techniques_zh":["测量光回波损耗并与参考值比较"],"techniques_cs":["Měření optického útlumu odrazu a porovnání s referenční hodnotou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\n1000 nm do 1700 nm od 3 dB do 32 dB CMC 0,5 dB\n1000 nm do 1700 nm od 32 dB do 42 dB CMC 0,7 dB\n1000 nm do 1700 nm od 42 dB do 52 dB CMC 1,0 dB\n1000 nm do 1700 nm od 52 dB do 61 dB CMC 1,5 dB\nPomiar tłumienia odbiciowego i porównanie z wartością odniesienia","reference":"PPKL 2.4 (ČSN EN 61300-3-6 ed. 2)","norm_bases":["PPKL 2.4","ČSN EN 61300-3-6 ed. 2"],"lab_section":"OPTOKON Malezja","lab_section_en":"OPTOKON Malaysia","lab_section_zh":"OPTOKON 马来西亚","lab_section_cs":"OPTOKON Malaysia","lab_address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 11900 Bayan Lepas, Penang, MALAYSIA","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłumienie odbiciowe / miernik tłumienia odbiciowego Wzorcowanie – wielkości optyczne Pomiar tłumienia odbiciowego i porównanie z wartością odniesienia 1000 nm do 1700 nm od 3 dB do 32 dB CMC 0,5 dB 1000 nm do 1700 nm od 32 dB do 42 dB CMC 0,7 dB 1000 nm do 1700 nm od 42 dB do 52 dB CMC 1,0 dB 1000 nm do 1700 nm od 52 dB do 61 dB CMC 1,5 dB Optický útlum odrazu / měřidlo optického útlumu odrazu Kalibrace – optické veličiny Měření optického útlumu odrazu a porovnání s referenční hodnotou 1000 nm až 1700 nm 3 dB až 32 dB CMC 0,5 dB 1000 nm až 1700 nm 32 dB až 42 dB CMC 0,7 dB 1000 nm až 1700 nm 42 dB až 52 dB CMC 1,0 dB 1000 nm až 1700 nm 52 dB až 61 dB CMC 1,5 dB PPKL 2.4 (ČSN EN 61300-3-6 ed. 2) Tlumienie odbiciowe / miernik tlumienia odbiciowego Wzorcowanie – wielkosci optyczne Pomiar tlumienia odbiciowego i porownanie z wartoscia odniesienia 1000 nm do 1700 nm od 3 dB do 32 dB CMC 0,5 dB 1000 nm do 1700 nm od 32 dB do 42 dB CMC 0,7 dB 1000 nm do 1700 nm od 42 dB do 52 dB CMC 1,0 dB 1000 nm do 1700 nm od 52 dB do 61 dB CMC 1,5 dB Opticky utlum odrazu / meridlo optickeho utlumu odrazu Kalibrace – opticke veliciny Mereni optickeho utlumu odrazu a porovnani s referencni hodnotou 1000 nm az 1700 nm 3 dB az 32 dB CMC 0,5 dB 1000 nm az 1700 nm 32 dB az 42 dB CMC 0,7 dB 1000 nm az 1700 nm 42 dB az 52 dB CMC 1,0 dB 1000 nm az 1700 nm 52 dB az 61 dB CMC 1,5 dB PPKL 2.4 (CSN EN 61300-3-6 ed. 2)","search_en":"Optical return loss / optical return loss meter Calibration – optical quantities Measurement of optical return loss and comparison with a reference value OPTOKON Malaysia CMC for the field of measured quantity: Optical quantities Measurement of optical return loss and comparison with a reference value 1000 nm to 1700 nm 1000 nm to 1700 nm 1000 nm to 1700 nm 1000 nm to 1700 nm PPKL 2.4 (ČSN EN 61300-3-6 ed. 2)","search_zh":"光回波损耗 / 光回波损耗测量仪 校准 – 光学量 测量光回波损耗并与参考值比较 OPTOKON 马来西亚 被测量领域的CMC：光学量 测量光回波损耗并与参考值比较 1000 nm 至 1700 nm 1000 nm 至 1700 nm 1000 nm 至 1700 nm 1000 nm 至 1700 nm PPKL 2.4 (ČSN EN 61300-3-6 第2版)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Malaysia","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1000 nm bis 1700 nm","range":"von 3 dB bis 32 dB","cmc":"0,5 dB"},{"name":"1000 nm bis 1700 nm","range":"von 32 dB bis 42 dB","cmc":"0,7 dB"},{"name":"1000 nm bis 1700 nm","range":"von 42 dB bis 52 dB","cmc":"1,0 dB"},{"name":"1000 nm bis 1700 nm","range":"von 52 dB bis 61 dB","cmc":"1,5 dB"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Rückflussdämpfung / Rückflussdämpfungsmessgerät Kalibrierung – optische Größen Messung der Rückflussdämpfung und Vergleich mit dem Referenzwert OPTOKON Malaysia CMC für den Messgrößenbereich: optische Größen Messung der Rückflussdämpfung und Vergleich mit dem Referenzwert 1000 nm bis 1700 nm 1000 nm bis 1700 nm 1000 nm bis 1700 nm 1000 nm bis 1700 nm PPKL 2.4 (ČSN EN 61300-3-6 Ausg. 2)","technique_de":"Messung der Rückflussdämpfung und Vergleich mit dem Referenzwert","techniques_de":["Messung der Rückflussdämpfung und Vergleich mit dem Referenzwert"],"test_object_de":"Rückflussdämpfung / Rückflussdämpfungsmessgerät","reference_de":"PPKL 2.4 (ČSN EN 61300-3-6 Ausg. 2)","reference_zh":"PPKL 2.4 (ČSN EN 61300-3-6 第2版)","reference_pl":"PPKL 2.4 (ČSN EN 61300-3-6 wyd. 2)"},{"_id":"64eb8a2eccb7e6e311cd8cff","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"5","test_object":"Długość optyczna włókna SMF / reflektometry optyczne OTDR","test_object_en":"Optical length of SMF fibre / OTDR optical reflectometers","test_object_zh":"SMF光纤光学长度 / OTDR光时域反射仪","test_object_cs":"Optická délka SMF vlákna / optické reflektometry OTDR","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"od 0 km do 50 km","cmc":"0,40 m"}],"parameters_en":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 km to 50 km","cmc":"0,40 m"}],"parameters_zh":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 km 至 50 km","cmc":"0,40 m"}],"parameters_cs":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 km až 50 km","cmc":"0,40 m"}],"technique":"Metoda oparta na światłowodowej linii opóźniającej","technique_en":"Method based on an optical fibre delay line","technique_zh":"基于光纤延迟线的方法","technique_cs":"Metoda založená na zpožďovací lince z optického vlákna","techniques":["Metoda oparta na światłowodowej linii opóźniającej"],"techniques_en":["Method based on an optical fibre delay line"],"techniques_zh":["基于光纤延迟线的方法"],"techniques_cs":["Metoda založená na zpožďovací lince z optického vlákna"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\n1310 nm, 1550 nm, 1625 nm od 0 km do 50 km CMC 0,40 m\nMetoda oparta na światłowodowej linii opóźniającej","reference":"PPKL 2.5 (ČSN EN 61746-1)","norm_bases":["PPKL 2.5","ČSN EN 61746-1"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długość optyczna włókna SMF / reflektometry optyczne OTDR Wzorcowanie – wielkości optyczne Metoda oparta na światłowodowej linii opóźniającej 1310 nm, 1550 nm, 1625 nm od 0 km do 50 km CMC 0,40 m Optická délka SMF vlákna / optické reflektometry OTDR Kalibrace – optické veličiny Metoda založená na zpožďovací lince z optického vlákna 1310 nm, 1550 nm, 1625 nm 0 km až 50 km CMC 0,40 m PPKL 2.5 (ČSN EN 61746-1) Dlugosc optyczna wlokna SMF / reflektometry optyczne OTDR Wzorcowanie – wielkosci optyczne Metoda oparta na swiatlowodowej linii opozniajacej 1310 nm, 1550 nm, 1625 nm od 0 km do 50 km CMC 0,40 m Opticka delka SMF vlakna / opticke reflektometry OTDR Kalibrace – opticke veliciny Metoda zalozena na zpozdovaci lince z optickeho vlakna 1310 nm, 1550 nm, 1625 nm 0 km az 50 km CMC 0,40 m PPKL 2.5 (CSN EN 61746-1)","search_en":"Optical length of SMF fibre / OTDR optical reflectometers Calibration – optical quantities Method based on an optical fibre delay line OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities Method based on an optical fibre delay line 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","search_zh":"SMF光纤光学长度 / OTDR光时域反射仪 校准 – 光学量 基于光纤延迟线的方法 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 基于光纤延迟线的方法 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"von 0 km bis 50 km","cmc":"0,40 m"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Länge der SMF-Faser / optische Rückstreumessgeräte OTDR Kalibrierung – optische Größen Verfahren auf Basis einer faseroptischen Verzögerungsleitung OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen Verfahren auf Basis einer faseroptischen Verzögerungsleitung 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","technique_de":"Verfahren auf Basis einer faseroptischen Verzögerungsleitung","techniques_de":["Verfahren auf Basis einer faseroptischen Verzögerungsleitung"],"test_object_de":"Optische Länge der SMF-Faser / optische Rückstreumessgeräte OTDR"},{"_id":"753a1af60186dfd886d733a8","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"5","test_object":"Długość optyczna włókna SMF / reflektometry optyczne OTDR","test_object_en":"Optical length of SMF fibre / OTDR optical reflectometers","test_object_zh":"SMF光纤光学长度 / OTDR光时域反射仪","test_object_cs":"Optická délka SMF vlákna / optické reflektometry OTDR","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"od 0 km do 50 km","cmc":"0,40 m"}],"parameters_en":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 km to 50 km","cmc":"0,40 m"}],"parameters_zh":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 km 至 50 km","cmc":"0,40 m"}],"parameters_cs":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 km až 50 km","cmc":"0,40 m"}],"technique":"Metoda oparta na światłowodowej linii opóźniającej","technique_en":"Method based on an optical fibre delay line","technique_zh":"基于光纤延迟线的方法","technique_cs":"Metoda založená na zpožďovací lince z optického vlákna","techniques":["Metoda oparta na światłowodowej linii opóźniającej"],"techniques_en":["Method based on an optical fibre delay line"],"techniques_zh":["基于光纤延迟线的方法"],"techniques_cs":["Metoda založená na zpožďovací lince z optického vlákna"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\n1310 nm, 1550 nm, 1625 nm od 0 km do 50 km CMC 0,40 m\nMetoda oparta na światłowodowej linii opóźniającej","reference":"PPKL 2.5 (ČSN EN 61746-1)","norm_bases":["PPKL 2.5","ČSN EN 61746-1"],"lab_section":"OPTOKON Malezja","lab_section_en":"OPTOKON Malaysia","lab_section_zh":"OPTOKON 马来西亚","lab_section_cs":"OPTOKON Malaysia","lab_address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 11900 Bayan Lepas, Penang, MALAYSIA","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długość optyczna włókna SMF / reflektometry optyczne OTDR Wzorcowanie – wielkości optyczne Metoda oparta na światłowodowej linii opóźniającej 1310 nm, 1550 nm, 1625 nm od 0 km do 50 km CMC 0,40 m Optická délka SMF vlákna / optické reflektometry OTDR Kalibrace – optické veličiny Metoda založená na zpožďovací lince z optického vlákna 1310 nm, 1550 nm, 1625 nm 0 km až 50 km CMC 0,40 m PPKL 2.5 (ČSN EN 61746-1) Dlugosc optyczna wlokna SMF / reflektometry optyczne OTDR Wzorcowanie – wielkosci optyczne Metoda oparta na swiatlowodowej linii opozniajacej 1310 nm, 1550 nm, 1625 nm od 0 km do 50 km CMC 0,40 m Opticka delka SMF vlakna / opticke reflektometry OTDR Kalibrace – opticke veliciny Metoda zalozena na zpozdovaci lince z optickeho vlakna 1310 nm, 1550 nm, 1625 nm 0 km az 50 km CMC 0,40 m PPKL 2.5 (CSN EN 61746-1)","search_en":"Optical length of SMF fibre / OTDR optical reflectometers Calibration – optical quantities Method based on an optical fibre delay line OPTOKON Malaysia CMC for the field of measured quantity: Optical quantities Method based on an optical fibre delay line 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","search_zh":"SMF光纤光学长度 / OTDR光时域反射仪 校准 – 光学量 基于光纤延迟线的方法 OPTOKON 马来西亚 被测量领域的CMC：光学量 基于光纤延迟线的方法 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Malaysia","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"von 0 km bis 50 km","cmc":"0,40 m"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Länge der SMF-Faser / optische Rückstreumessgeräte OTDR Kalibrierung – optische Größen Verfahren auf Basis einer faseroptischen Verzögerungsleitung OPTOKON Malaysia CMC für den Messgrößenbereich: optische Größen Verfahren auf Basis einer faseroptischen Verzögerungsleitung 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","technique_de":"Verfahren auf Basis einer faseroptischen Verzögerungsleitung","techniques_de":["Verfahren auf Basis einer faseroptischen Verzögerungsleitung"],"test_object_de":"Optische Länge der SMF-Faser / optische Rückstreumessgeräte OTDR"},{"_id":"7d23facb6b0a634e6d704522","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"5","test_object":"Długość optyczna włókna MMF / reflektometry optyczne","test_object_en":"Optical length of MMF fibre / optical reflectometers","test_object_zh":"MMF光纤光学长度 / 光反射仪","test_object_cs":"Optická délka MMF vlákna / optické reflektometry","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"850 nm, 1300 nm","range":"od 0 km do 5 km","cmc":"0,20 m"}],"parameters_en":[{"name":"850 nm, 1300 nm","range":"0 km to 5 km","cmc":"0,20 m"}],"parameters_zh":[{"name":"850 nm, 1300 nm","range":"0 km 至 5 km","cmc":"0,20 m"}],"parameters_cs":[{"name":"850 nm, 1300 nm","range":"0 km až 5 km","cmc":"0,20 m"}],"technique":"Metoda oparta na światłowodowej linii opóźniającej","technique_en":"Method based on an optical fibre delay line","technique_zh":"基于光纤延迟线的方法","technique_cs":"Metoda založená na zpožďovací lince z optického vlákna","techniques":["Metoda oparta na światłowodowej linii opóźniającej"],"techniques_en":["Method based on an optical fibre delay line"],"techniques_zh":["基于光纤延迟线的方法"],"techniques_cs":["Metoda založená na zpožďovací lince z optického vlákna"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\n850 nm, 1300 nm od 0 km do 5 km CMC 0,20 m\nMetoda oparta na światłowodowej linii opóźniającej","reference":"PPKL 2.5 (ČSN EN 61746-2)","norm_bases":["PPKL 2.5","ČSN EN 61746-2"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długość optyczna włókna MMF / reflektometry optyczne Wzorcowanie – wielkości optyczne Metoda oparta na światłowodowej linii opóźniającej 850 nm, 1300 nm od 0 km do 5 km CMC 0,20 m Optická délka MMF vlákna / optické reflektometry Kalibrace – optické veličiny Metoda založená na zpožďovací lince z optického vlákna 850 nm, 1300 nm 0 km až 5 km CMC 0,20 m PPKL 2.5 (ČSN EN 61746-2) Dlugosc optyczna wlokna MMF / reflektometry optyczne Wzorcowanie – wielkosci optyczne Metoda oparta na swiatlowodowej linii opozniajacej 850 nm, 1300 nm od 0 km do 5 km CMC 0,20 m Opticka delka MMF vlakna / opticke reflektometry Kalibrace – opticke veliciny Metoda zalozena na zpozdovaci lince z optickeho vlakna 850 nm, 1300 nm 0 km az 5 km CMC 0,20 m PPKL 2.5 (CSN EN 61746-2)","search_en":"Optical length of MMF fibre / optical reflectometers Calibration – optical quantities Method based on an optical fibre delay line OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities Method based on an optical fibre delay line 850 nm, 1300 nm PPKL 2.5 (ČSN EN 61746-2)","search_zh":"MMF光纤光学长度 / 光反射仪 校准 – 光学量 基于光纤延迟线的方法 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 基于光纤延迟线的方法 850 nm, 1300 nm PPKL 2.5 (ČSN EN 61746-2)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"850 nm, 1300 nm","range":"von 0 km bis 5 km","cmc":"0,20 m"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Länge der MMF-Faser / optische Rückstreumessgeräte Kalibrierung – optische Größen Verfahren auf Basis einer faseroptischen Verzögerungsleitung OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen Verfahren auf Basis einer faseroptischen Verzögerungsleitung 850 nm, 1300 nm PPKL 2.5 (ČSN EN 61746-2)","technique_de":"Verfahren auf Basis einer faseroptischen Verzögerungsleitung","techniques_de":["Verfahren auf Basis einer faseroptischen Verzögerungsleitung"],"test_object_de":"Optische Länge der MMF-Faser / optische Rückstreumessgeräte"},{"_id":"6d0b4f78f68a43b57a158cfe","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"5","test_object":"Tłumienie optyczne włókna SMF / reflektometry optyczne OTDR","test_object_en":"Optical attenuation of SMF fibre / OTDR optical reflectometers","test_object_zh":"SMF光纤光衰减 / OTDR光时域反射仪","test_object_cs":"Optický útlum SMF vlákna / optické reflektometry OTDR","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"od 0 dB do 20 dB","cmc":"0,02 dB"}],"parameters_en":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 dB to 20 dB","cmc":"0,02 dB"}],"parameters_zh":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 dB 至 20 dB","cmc":"0,02 dB"}],"parameters_cs":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 dB až 20 dB","cmc":"0,02 dB"}],"technique":"Pomiar tłumienia OTDR dla różnych poziomów mocy i różnych odległości","technique_en":"OTDR measurement of attenuation for various power levels and various distances","technique_zh":"针对不同功率电平和不同距离的OTDR衰减测量","technique_cs":"OTDR měření útlumu pro různé výkonové úrovně a pro různé vzdálenosti","techniques":["Pomiar tłumienia OTDR dla różnych poziomów mocy i różnych odległości"],"techniques_en":["OTDR measurement of attenuation for various power levels and various distances"],"techniques_zh":["针对不同功率电平和不同距离的OTDR衰减测量"],"techniques_cs":["OTDR měření útlumu pro různé výkonové úrovně a pro různé vzdálenosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\n1310 nm, 1550 nm, 1625 nm od 0 dB do 20 dB CMC 0,02 dB\nPomiar tłumienia OTDR dla różnych poziomów mocy i różnych odległości","reference":"PPKL 2.5 (ČSN EN 61746-1)","norm_bases":["PPKL 2.5","ČSN EN 61746-1"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłumienie optyczne włókna SMF / reflektometry optyczne OTDR Wzorcowanie – wielkości optyczne Pomiar tłumienia OTDR dla różnych poziomów mocy i różnych odległości 1310 nm, 1550 nm, 1625 nm od 0 dB do 20 dB CMC 0,02 dB Optický útlum SMF vlákna / optické reflektometry OTDR Kalibrace – optické veličiny OTDR měření útlumu pro různé výkonové úrovně a pro různé vzdálenosti 1310 nm, 1550 nm, 1625 nm 0 dB až 20 dB CMC 0,02 dB PPKL 2.5 (ČSN EN 61746-1) Tlumienie optyczne wlokna SMF / reflektometry optyczne OTDR Wzorcowanie – wielkosci optyczne Pomiar tlumienia OTDR dla roznych poziomow mocy i roznych odleglosci 1310 nm, 1550 nm, 1625 nm od 0 dB do 20 dB CMC 0,02 dB Opticky utlum SMF vlakna / opticke reflektometry OTDR Kalibrace – opticke veliciny OTDR mereni utlumu pro ruzne vykonove urovne a pro ruzne vzdalenosti 1310 nm, 1550 nm, 1625 nm 0 dB az 20 dB CMC 0,02 dB PPKL 2.5 (CSN EN 61746-1)","search_en":"Optical attenuation of SMF fibre / OTDR optical reflectometers Calibration – optical quantities OTDR measurement of attenuation for various power levels and various distances OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities OTDR measurement of attenuation for various power levels and various distances 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","search_zh":"SMF光纤光衰减 / OTDR光时域反射仪 校准 – 光学量 针对不同功率电平和不同距离的OTDR衰减测量 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 针对不同功率电平和不同距离的OTDR衰减测量 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"von 0 dB bis 20 dB","cmc":"0,02 dB"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Dämpfung von SMF-Fasern / optische Rückstreumessgeräte OTDR Kalibrierung – optische Größen OTDR-Dämpfungsmessung für verschiedene Leistungspegel und Entfernungen OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen OTDR-Dämpfungsmessung für verschiedene Leistungspegel und Entfernungen 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","technique_de":"OTDR-Dämpfungsmessung für verschiedene Leistungspegel und Entfernungen","techniques_de":["OTDR-Dämpfungsmessung für verschiedene Leistungspegel und Entfernungen"],"test_object_de":"Optische Dämpfung von SMF-Fasern / optische Rückstreumessgeräte OTDR"},{"_id":"76eeffa5c1038c71294a7ccc","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"5","test_object":"Tłumienie optyczne włókna SMF / reflektometry optyczne OTDR","test_object_en":"Optical attenuation of SMF fibre / OTDR optical reflectometers","test_object_zh":"SMF光纤光衰减 / OTDR光时域反射仪","test_object_cs":"Optický útlum SMF vlákna / optické reflektometry OTDR","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"od 0 dB do 20 dB","cmc":"0,02 dB"}],"parameters_en":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 dB to 20 dB","cmc":"0,02 dB"}],"parameters_zh":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 dB 至 20 dB","cmc":"0,02 dB"}],"parameters_cs":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"0 dB až 20 dB","cmc":"0,02 dB"}],"technique":"Pomiar tłumienia OTDR dla różnych poziomów mocy i różnych odległości","technique_en":"OTDR measurement of attenuation for various power levels and various distances","technique_zh":"针对不同功率电平和不同距离的OTDR衰减测量","technique_cs":"OTDR měření útlumu pro různé výkonové úrovně a pro různé vzdálenosti","techniques":["Pomiar tłumienia OTDR dla różnych poziomów mocy i różnych odległości"],"techniques_en":["OTDR measurement of attenuation for various power levels and various distances"],"techniques_zh":["针对不同功率电平和不同距离的OTDR衰减测量"],"techniques_cs":["OTDR měření útlumu pro různé výkonové úrovně a pro různé vzdálenosti"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\n1310 nm, 1550 nm, 1625 nm od 0 dB do 20 dB CMC 0,02 dB\nPomiar tłumienia OTDR dla różnych poziomów mocy i różnych odległości","reference":"PPKL 2.5 (ČSN EN 61746-1)","norm_bases":["PPKL 2.5","ČSN EN 61746-1"],"lab_section":"OPTOKON Malezja","lab_section_en":"OPTOKON Malaysia","lab_section_zh":"OPTOKON 马来西亚","lab_section_cs":"OPTOKON Malaysia","lab_address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 11900 Bayan Lepas, Penang, MALAYSIA","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tłumienie optyczne włókna SMF / reflektometry optyczne OTDR Wzorcowanie – wielkości optyczne Pomiar tłumienia OTDR dla różnych poziomów mocy i różnych odległości 1310 nm, 1550 nm, 1625 nm od 0 dB do 20 dB CMC 0,02 dB Optický útlum SMF vlákna / optické reflektometry OTDR Kalibrace – optické veličiny OTDR měření útlumu pro různé výkonové úrovně a pro různé vzdálenosti 1310 nm, 1550 nm, 1625 nm 0 dB až 20 dB CMC 0,02 dB PPKL 2.5 (ČSN EN 61746-1) Tlumienie optyczne wlokna SMF / reflektometry optyczne OTDR Wzorcowanie – wielkosci optyczne Pomiar tlumienia OTDR dla roznych poziomow mocy i roznych odleglosci 1310 nm, 1550 nm, 1625 nm od 0 dB do 20 dB CMC 0,02 dB Opticky utlum SMF vlakna / opticke reflektometry OTDR Kalibrace – opticke veliciny OTDR mereni utlumu pro ruzne vykonove urovne a pro ruzne vzdalenosti 1310 nm, 1550 nm, 1625 nm 0 dB az 20 dB CMC 0,02 dB PPKL 2.5 (CSN EN 61746-1)","search_en":"Optical attenuation of SMF fibre / OTDR optical reflectometers Calibration – optical quantities OTDR measurement of attenuation for various power levels and various distances OPTOKON Malaysia CMC for the field of measured quantity: Optical quantities OTDR measurement of attenuation for various power levels and various distances 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","search_zh":"SMF光纤光衰减 / OTDR光时域反射仪 校准 – 光学量 针对不同功率电平和不同距离的OTDR衰减测量 OPTOKON 马来西亚 被测量领域的CMC：光学量 针对不同功率电平和不同距离的OTDR衰减测量 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Malaysia","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1310 nm, 1550 nm, 1625 nm","range":"von 0 dB bis 20 dB","cmc":"0,02 dB"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Dämpfung von SMF-Fasern / optische Rückstreumessgeräte OTDR Kalibrierung – optische Größen OTDR-Dämpfungsmessung für verschiedene Leistungspegel und Entfernungen OPTOKON Malaysia CMC für den Messgrößenbereich: optische Größen OTDR-Dämpfungsmessung für verschiedene Leistungspegel und Entfernungen 1310 nm, 1550 nm, 1625 nm PPKL 2.5 (ČSN EN 61746-1)","technique_de":"OTDR-Dämpfungsmessung für verschiedene Leistungspegel und Entfernungen","techniques_de":["OTDR-Dämpfungsmessung für verschiedene Leistungspegel und Entfernungen"],"test_object_de":"Optische Dämpfung von SMF-Fasern / optische Rückstreumessgeräte OTDR"},{"_id":"20344c9c820bd0dd5169071a","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"6","test_object":"Czułość widmowa / detektory promieniowania optycznego – fotodiody Newport 818-xx","test_object_en":"Spectral responsivity / optical radiation detectors – photodiodes Newport 818-xx","test_object_zh":"光谱响应度 / 光辐射探测器 – Newport 818-xx 光电二极管","test_object_cs":"Spektrální responzivita / detektory optického záření – fotodiody Newport 818-xx","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"635 nm do 940 nm, 1625 nm, 1650 nm przy mocy optycznej -10 dBm do -20 dBm","range":"od 0 do 1","cmc":"3 %"},{"name":"1270 nm do 1610 nm przy mocy optycznej -10 dBm do -20 dBm","range":"od 0 do 1","cmc":"2,6 %"}],"parameters_en":[{"name":"635 nm to 940 nm, 1625 nm, 1650 nm at optical power -10 dBm to -20 dBm","range":"0 to 1","cmc":"3 %"},{"name":"1270 nm to 1610 nm at optical power -10 dBm to -20 dBm","range":"0 to 1","cmc":"2,6 %"}],"parameters_zh":[{"name":"635 nm 至 940 nm、1625 nm、1650 nm，光功率 -10 dBm 至 -20 dBm","range":"0 至 1","cmc":"3 %"},{"name":"1270 nm 至 1610 nm，光功率 -10 dBm 至 -20 dBm","range":"0 至 1","cmc":"2,6 %"}],"parameters_cs":[{"name":"635 nm až 940 nm, 1625 nm, 1650 nm při optickém výkonu -10 dBm až -20 dBm","range":"0 až 1","cmc":"3 %"},{"name":"1270 nm až 1610 nm při optickém výkonu -10 dBm až -20 dBm","range":"0 až 1","cmc":"2,6 %"}],"technique":"Pomiar mocy optycznej i prądu","technique_en":"Measurement of optical power and current","technique_zh":"测量光功率和电流","technique_cs":"Měření optického výkonu a proudu","techniques":["Pomiar mocy optycznej i prądu"],"techniques_en":["Measurement of optical power and current"],"techniques_zh":["测量光功率和电流"],"techniques_cs":["Měření optického výkonu a proudu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\n635 nm do 940 nm, 1625 nm, 1650 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 3 %\n1270 nm do 1610 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 2,6 %\nPomiar mocy optycznej i prądu","reference":"PPKL 2.7","norm_bases":["PPKL 2.7"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czułość widmowa / detektory promieniowania optycznego – fotodiody Newport 818-xx Wzorcowanie – wielkości optyczne Pomiar mocy optycznej i prądu 635 nm do 940 nm, 1625 nm, 1650 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 3 % 1270 nm do 1610 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 2,6 % Spektrální responzivita / detektory optického záření – fotodiody Newport 818-xx Kalibrace – optické veličiny Měření optického výkonu a proudu 635 nm až 940 nm, 1625 nm, 1650 nm při optickém výkonu -10 dBm až -20 dBm 0 až 1 CMC 3 % 1270 nm až 1610 nm při optickém výkonu -10 dBm až -20 dBm 0 až 1 CMC 2,6 % PPKL 2.7 Czulosc widmowa / detektory promieniowania optycznego – fotodiody Newport 818-xx Wzorcowanie – wielkosci optyczne Pomiar mocy optycznej i pradu 635 nm do 940 nm, 1625 nm, 1650 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 3 % 1270 nm do 1610 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 2,6 % Spektralni responzivita / detektory optickeho zareni – fotodiody Newport 818-xx Kalibrace – opticke veliciny Mereni optickeho vykonu a proudu 635 nm az 940 nm, 1625 nm, 1650 nm pri optickem vykonu -10 dBm az -20 dBm 0 az 1 CMC 3 % 1270 nm az 1610 nm pri optickem vykonu -10 dBm az -20 dBm 0 az 1 CMC 2,6 % PPKL 2.7","search_en":"Spectral responsivity / optical radiation detectors – photodiodes Newport 818-xx Calibration – optical quantities Measurement of optical power and current OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities Measurement of optical power and current 635 nm to 940 nm, 1625 nm, 1650 nm at optical power -10 dBm to -20 dBm 1270 nm to 1610 nm at optical power -10 dBm to -20 dBm PPKL 2.7","search_zh":"光谱响应度 / 光辐射探测器 – Newport 818-xx 光电二极管 校准 – 光学量 测量光功率和电流 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 测量光功率和电流 635 nm 至 940 nm、1625 nm、1650 nm，光功率 -10 dBm 至 -20 dBm 1270 nm 至 1610 nm，光功率 -10 dBm 至 -20 dBm PPKL 2.7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"635 nm bis 940 nm, 1625 nm, 1650 nm bei einer optischen Leistung von -10 dBm bis -20 dBm","range":"von 0 bis 1","cmc":"3 %"},{"name":"1270 nm bis 1610 nm bei einer optischen Leistung von -10 dBm bis -20 dBm","range":"von 0 bis 1","cmc":"2,6 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Spektrale Empfindlichkeit / Detektoren für optische Strahlung – Photodioden Newport 818-xx Kalibrierung – optische Größen Messung der optischen Leistung und des Stroms OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen Messung der optischen Leistung und des Stroms 635 nm bis 940 nm, 1625 nm, 1650 nm bei einer optischen Leistung von -10 dBm bis -20 dBm 1270 nm bis 1610 nm bei einer optischen Leistung von -10 dBm bis -20 dBm PPKL 2.7","technique_de":"Messung der optischen Leistung und des Stroms","techniques_de":["Messung der optischen Leistung und des Stroms"],"test_object_de":"Spektrale Empfindlichkeit / Detektoren für optische Strahlung – Photodioden Newport 818-xx"},{"_id":"082e2ff22a947f1a0e1c0ba5","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"6","test_object":"Czułość widmowa / detektory promieniowania optycznego – fotodiody Newport 818-xx","test_object_en":"Spectral responsivity / optical radiation detectors – photodiodes Newport 818-xx","test_object_zh":"光谱响应度 / 光辐射探测器 – Newport 818-xx 光电二极管","test_object_cs":"Spektrální responzivita / detektory optického záření – fotodiody Newport 818-xx","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"635 nm do 940 nm, 1625 nm, 1650 nm przy mocy optycznej -10 dBm do -20 dBm","range":"od 0 do 1","cmc":"3 %"},{"name":"1270 nm do 1610 nm przy mocy optycznej -10 dBm do -20 dBm","range":"od 0 do 1","cmc":"2,6 %"}],"parameters_en":[{"name":"635 nm to 940 nm, 1625 nm, 1650 nm at optical power -10 dBm to -20 dBm","range":"0 to 1","cmc":"3 %"},{"name":"1270 nm to 1610 nm at optical power -10 dBm to -20 dBm","range":"0 to 1","cmc":"2,6 %"}],"parameters_zh":[{"name":"635 nm 至 940 nm、1625 nm、1650 nm，光功率 -10 dBm 至 -20 dBm","range":"0 至 1","cmc":"3 %"},{"name":"1270 nm 至 1610 nm，光功率 -10 dBm 至 -20 dBm","range":"0 至 1","cmc":"2,6 %"}],"parameters_cs":[{"name":"635 nm až 940 nm, 1625 nm, 1650 nm při optickém výkonu -10 dBm až -20 dBm","range":"0 až 1","cmc":"3 %"},{"name":"1270 nm až 1610 nm při optickém výkonu -10 dBm až -20 dBm","range":"0 až 1","cmc":"2,6 %"}],"technique":"Pomiar mocy optycznej i prądu","technique_en":"Measurement of optical power and current","technique_zh":"测量光功率和电流","technique_cs":"Měření optického výkonu a proudu","techniques":["Pomiar mocy optycznej i prądu"],"techniques_en":["Measurement of optical power and current"],"techniques_zh":["测量光功率和电流"],"techniques_cs":["Měření optického výkonu a proudu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\n635 nm do 940 nm, 1625 nm, 1650 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 3 %\n1270 nm do 1610 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 2,6 %\nPomiar mocy optycznej i prądu","reference":"PPKL 2.7","norm_bases":["PPKL 2.7"],"lab_section":"OPTOKON Malezja","lab_section_en":"OPTOKON Malaysia","lab_section_zh":"OPTOKON 马来西亚","lab_section_cs":"OPTOKON Malaysia","lab_address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 11900 Bayan Lepas, Penang, MALAYSIA","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czułość widmowa / detektory promieniowania optycznego – fotodiody Newport 818-xx Wzorcowanie – wielkości optyczne Pomiar mocy optycznej i prądu 635 nm do 940 nm, 1625 nm, 1650 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 3 % 1270 nm do 1610 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 2,6 % Spektrální responzivita / detektory optického záření – fotodiody Newport 818-xx Kalibrace – optické veličiny Měření optického výkonu a proudu 635 nm až 940 nm, 1625 nm, 1650 nm při optickém výkonu -10 dBm až -20 dBm 0 až 1 CMC 3 % 1270 nm až 1610 nm při optickém výkonu -10 dBm až -20 dBm 0 až 1 CMC 2,6 % PPKL 2.7 Czulosc widmowa / detektory promieniowania optycznego – fotodiody Newport 818-xx Wzorcowanie – wielkosci optyczne Pomiar mocy optycznej i pradu 635 nm do 940 nm, 1625 nm, 1650 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 3 % 1270 nm do 1610 nm przy mocy optycznej -10 dBm do -20 dBm od 0 do 1 CMC 2,6 % Spektralni responzivita / detektory optickeho zareni – fotodiody Newport 818-xx Kalibrace – opticke veliciny Mereni optickeho vykonu a proudu 635 nm az 940 nm, 1625 nm, 1650 nm pri optickem vykonu -10 dBm az -20 dBm 0 az 1 CMC 3 % 1270 nm az 1610 nm pri optickem vykonu -10 dBm az -20 dBm 0 az 1 CMC 2,6 % PPKL 2.7","search_en":"Spectral responsivity / optical radiation detectors – photodiodes Newport 818-xx Calibration – optical quantities Measurement of optical power and current OPTOKON Malaysia CMC for the field of measured quantity: Optical quantities Measurement of optical power and current 635 nm to 940 nm, 1625 nm, 1650 nm at optical power -10 dBm to -20 dBm 1270 nm to 1610 nm at optical power -10 dBm to -20 dBm PPKL 2.7","search_zh":"光谱响应度 / 光辐射探测器 – Newport 818-xx 光电二极管 校准 – 光学量 测量光功率和电流 OPTOKON 马来西亚 被测量领域的CMC：光学量 测量光功率和电流 635 nm 至 940 nm、1625 nm、1650 nm，光功率 -10 dBm 至 -20 dBm 1270 nm 至 1610 nm，光功率 -10 dBm 至 -20 dBm PPKL 2.7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Malaysia","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"635 nm bis 940 nm, 1625 nm, 1650 nm bei einer optischen Leistung von -10 dBm bis -20 dBm","range":"von 0 bis 1","cmc":"3 %"},{"name":"1270 nm bis 1610 nm bei einer optischen Leistung von -10 dBm bis -20 dBm","range":"von 0 bis 1","cmc":"2,6 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Spektrale Empfindlichkeit / Detektoren für optische Strahlung – Photodioden Newport 818-xx Kalibrierung – optische Größen Messung der optischen Leistung und des Stroms OPTOKON Malaysia CMC für den Messgrößenbereich: optische Größen Messung der optischen Leistung und des Stroms 635 nm bis 940 nm, 1625 nm, 1650 nm bei einer optischen Leistung von -10 dBm bis -20 dBm 1270 nm bis 1610 nm bei einer optischen Leistung von -10 dBm bis -20 dBm PPKL 2.7","technique_de":"Messung der optischen Leistung und des Stroms","techniques_de":["Messung der optischen Leistung und des Stroms"],"test_object_de":"Spektrale Empfindlichkeit / Detektoren für optische Strahlung – Photodioden Newport 818-xx"},{"_id":"c3f06a7c970ae9e71f8d943d","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"7","test_object":"Długość fali / optyczne analizatory widma","test_object_en":"Wavelength / optical spectrum analysers","test_object_zh":"波长 / 光谱分析仪","test_object_cs":"Vlnová délka / Optické spektrální analyzátory","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"","range":"od 1250 nm do 1650 nm","cmc":"0,2 nm"}],"parameters_en":[{"name":"","range":"from 1250 nm to 1650 nm","cmc":"0,2 nm"}],"parameters_zh":[{"name":"","range":"1250 nm 至 1650 nm","cmc":"0,2 nm"}],"parameters_cs":[{"name":"","range":"1250 nm až 1650 nm","cmc":"0,2 nm"}],"technique":"Porównanie z wzorcowym miernikiem długości fali","technique_en":"Comparison with a wavelength meter standard","technique_zh":"与标准波长计比较","technique_cs":"Porovnání s etalonovým měřidlem vlnové délky","techniques":["Porównanie z wzorcowym miernikiem długości fali"],"techniques_en":["Comparison with a wavelength meter standard"],"techniques_zh":["与标准波长计比较"],"techniques_cs":["Porovnání s etalonovým měřidlem vlnové délky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nod 1250 nm do 1650 nm CMC 0,2 nm\nPorównanie z wzorcowym miernikiem długości fali","reference":"PPKL 2.6 (ČSN EN 62129-1)","norm_bases":["PPKL 2.6","ČSN EN 62129-1"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długość fali / optyczne analizatory widma Wzorcowanie – wielkości optyczne Porównanie z wzorcowym miernikiem długości fali od 1250 nm do 1650 nm CMC 0,2 nm Vlnová délka / Optické spektrální analyzátory Kalibrace – optické veličiny Porovnání s etalonovým měřidlem vlnové délky 1250 nm až 1650 nm CMC 0,2 nm PPKL 2.6 (ČSN EN 62129-1) Dlugosc fali / optyczne analizatory widma Wzorcowanie – wielkosci optyczne Porownanie z wzorcowym miernikiem dlugosci fali od 1250 nm do 1650 nm CMC 0,2 nm Vlnova delka / Opticke spektralni analyzatory Kalibrace – opticke veliciny Porovnani s etalonovym meridlem vlnove delky 1250 nm az 1650 nm CMC 0,2 nm PPKL 2.6 (CSN EN 62129-1)","search_en":"Wavelength / optical spectrum analysers Calibration – optical quantities Comparison with a wavelength meter standard OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities Comparison with a wavelength meter standard PPKL 2.6 (ČSN EN 62129-1)","search_zh":"波长 / 光谱分析仪 校准 – 光学量 与标准波长计比较 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 与标准波长计比较 PPKL 2.6 (ČSN EN 62129-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"","range":"von 1250 nm bis 1650 nm","cmc":"0,2 nm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Wellenlänge / optische Spektrumanalysatoren Kalibrierung – optische Größen Vergleich mit Referenz-Wellenlängenmessgerät OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen Vergleich mit Referenz-Wellenlängenmessgerät PPKL 2.6 (ČSN EN 62129-1)","technique_de":"Vergleich mit Referenz-Wellenlängenmessgerät","techniques_de":["Vergleich mit Referenz-Wellenlängenmessgerät"],"test_object_de":"Wellenlänge / optische Spektrumanalysatoren"},{"_id":"c071bc6013b2b9942a455117","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"7","test_object":"Długość fali / optyczne analizatory widma","test_object_en":"Wavelength / optical spectrum analysers","test_object_zh":"波长 / 光谱分析仪","test_object_cs":"Vlnová délka / Optické spektrální analyzátory","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"","range":"od 1250 nm do 1650 nm","cmc":"0,2 nm"}],"parameters_en":[{"name":"","range":"from 1250 nm to 1650 nm","cmc":"0,2 nm"}],"parameters_zh":[{"name":"","range":"1250 nm 至 1650 nm","cmc":"0,2 nm"}],"parameters_cs":[{"name":"","range":"1250 nm až 1650 nm","cmc":"0,2 nm"}],"technique":"Porównanie z wzorcowym miernikiem długości fali","technique_en":"Comparison with a wavelength meter standard","technique_zh":"与标准波长计比较","technique_cs":"Porovnání s etalonovým měřidlem vlnové délky","techniques":["Porównanie z wzorcowym miernikiem długości fali"],"techniques_en":["Comparison with a wavelength meter standard"],"techniques_zh":["与标准波长计比较"],"techniques_cs":["Porovnání s etalonovým měřidlem vlnové délky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nod 1250 nm do 1650 nm CMC 0,2 nm\nPorównanie z wzorcowym miernikiem długości fali","reference":"PPKL 2.6 (ČSN EN 62129-1)","norm_bases":["PPKL 2.6","ČSN EN 62129-1"],"lab_section":"OPTOKON Malezja","lab_section_en":"OPTOKON Malaysia","lab_section_zh":"OPTOKON 马来西亚","lab_section_cs":"OPTOKON Malaysia","lab_address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 11900 Bayan Lepas, Penang, MALAYSIA","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Długość fali / optyczne analizatory widma Wzorcowanie – wielkości optyczne Porównanie z wzorcowym miernikiem długości fali od 1250 nm do 1650 nm CMC 0,2 nm Vlnová délka / Optické spektrální analyzátory Kalibrace – optické veličiny Porovnání s etalonovým měřidlem vlnové délky 1250 nm až 1650 nm CMC 0,2 nm PPKL 2.6 (ČSN EN 62129-1) Dlugosc fali / optyczne analizatory widma Wzorcowanie – wielkosci optyczne Porownanie z wzorcowym miernikiem dlugosci fali od 1250 nm do 1650 nm CMC 0,2 nm Vlnova delka / Opticke spektralni analyzatory Kalibrace – opticke veliciny Porovnani s etalonovym meridlem vlnove delky 1250 nm az 1650 nm CMC 0,2 nm PPKL 2.6 (CSN EN 62129-1)","search_en":"Wavelength / optical spectrum analysers Calibration – optical quantities Comparison with a wavelength meter standard OPTOKON Malaysia CMC for the field of measured quantity: Optical quantities Comparison with a wavelength meter standard PPKL 2.6 (ČSN EN 62129-1)","search_zh":"波长 / 光谱分析仪 校准 – 光学量 与标准波长计比较 OPTOKON 马来西亚 被测量领域的CMC：光学量 与标准波长计比较 PPKL 2.6 (ČSN EN 62129-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Malaysia","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"","range":"von 1250 nm bis 1650 nm","cmc":"0,2 nm"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Wellenlänge / optische Spektrumanalysatoren Kalibrierung – optische Größen Vergleich mit Referenz-Wellenlängenmessgerät OPTOKON Malaysia CMC für den Messgrößenbereich: optische Größen Vergleich mit Referenz-Wellenlängenmessgerät PPKL 2.6 (ČSN EN 62129-1)","technique_de":"Vergleich mit Referenz-Wellenlängenmessgerät","techniques_de":["Vergleich mit Referenz-Wellenlängenmessgerät"],"test_object_de":"Wellenlänge / optische Spektrumanalysatoren"},{"_id":"949d585f823e39da5e8e9e94","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"7","test_object":"Moc optyczna / optyczne analizatory widma","test_object_en":"Optical power / optical spectrum analysers","test_object_zh":"光功率 / 光谱分析仪","test_object_cs":"Optický výkon / Optické spektrální analyzátory","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1250 nm do 1650 nm","range":"od -40 dBm do +10 dBm","cmc":"2,5 %"}],"parameters_en":[{"name":"1250 nm to 1650 nm","range":"-40 dBm to +10 dBm","cmc":"2,5 %"}],"parameters_zh":[{"name":"1250 nm 至 1650 nm","range":"-40 dBm 至 +10 dBm","cmc":"2,5 %"}],"parameters_cs":[{"name":"1250 nm až 1650 nm","range":"-40 dBm až +10 dBm","cmc":"2,5 %"}],"technique":"Porównanie z wzorcowym miernikiem mocy optycznej","technique_en":"Comparison with an optical power meter standard","technique_zh":"与标准光功率计比较","technique_cs":"Porovnání s etalonovým měřidlem optického výkonu","techniques":["Porównanie z wzorcowym miernikiem mocy optycznej"],"techniques_en":["Comparison with an optical power meter standard"],"techniques_zh":["与标准光功率计比较"],"techniques_cs":["Porovnání s etalonovým měřidlem optického výkonu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\n1250 nm do 1650 nm od -40 dBm do +10 dBm CMC 2,5 %\nPorównanie z wzorcowym miernikiem mocy optycznej","reference":"PPKL 2.1 (ČSN EN 61315 ed. 2)","norm_bases":["PPKL 2.1","ČSN EN 61315 ed. 2"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc optyczna / optyczne analizatory widma Wzorcowanie – wielkości optyczne Porównanie z wzorcowym miernikiem mocy optycznej 1250 nm do 1650 nm od -40 dBm do +10 dBm CMC 2,5 % Optický výkon / Optické spektrální analyzátory Kalibrace – optické veličiny Porovnání s etalonovým měřidlem optického výkonu 1250 nm až 1650 nm -40 dBm až +10 dBm CMC 2,5 % PPKL 2.1 (ČSN EN 61315 ed. 2) Moc optyczna / optyczne analizatory widma Wzorcowanie – wielkosci optyczne Porownanie z wzorcowym miernikiem mocy optycznej 1250 nm do 1650 nm od -40 dBm do +10 dBm CMC 2,5 % Opticky vykon / Opticke spektralni analyzatory Kalibrace – opticke veliciny Porovnani s etalonovym meridlem optickeho vykonu 1250 nm az 1650 nm -40 dBm az +10 dBm CMC 2,5 % PPKL 2.1 (CSN EN 61315 ed. 2)","search_en":"Optical power / optical spectrum analysers Calibration – optical quantities Comparison with an optical power meter standard OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities Comparison with an optical power meter standard 1250 nm to 1650 nm PPKL 2.1 (ČSN EN 61315 ed. 2)","search_zh":"光功率 / 光谱分析仪 校准 – 光学量 与标准光功率计比较 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 与标准光功率计比较 1250 nm 至 1650 nm PPKL 2.1 (ČSN EN 61315 第2版)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1250 nm bis 1650 nm","range":"von -40 dBm bis +10 dBm","cmc":"2,5 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Leistung / optische Spektrumanalysatoren Kalibrierung – optische Größen Vergleich mit optischem Referenz-Leistungsmesser OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen Vergleich mit optischem Referenz-Leistungsmesser 1250 nm bis 1650 nm PPKL 2.1 (ČSN EN 61315 Ausg. 2)","technique_de":"Vergleich mit optischem Referenz-Leistungsmesser","techniques_de":["Vergleich mit optischem Referenz-Leistungsmesser"],"test_object_de":"Optische Leistung / optische Spektrumanalysatoren","reference_de":"PPKL 2.1 (ČSN EN 61315 Ausg. 2)","reference_zh":"PPKL 2.1 (ČSN EN 61315 第2版)","reference_pl":"PPKL 2.1 (ČSN EN 61315 wyd. 2)"},{"_id":"bd0e426b23a154645c1fdc41","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"7","test_object":"Moc optyczna / optyczne analizatory widma","test_object_en":"Optical power / optical spectrum analysers","test_object_zh":"光功率 / 光谱分析仪","test_object_cs":"Optický výkon / Optické spektrální analyzátory","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1250 nm do 1650 nm","range":"od -40 dBm do +10 dBm","cmc":"2,5 %"}],"parameters_en":[{"name":"1250 nm to 1650 nm","range":"-40 dBm to +10 dBm","cmc":"2,5 %"}],"parameters_zh":[{"name":"1250 nm 至 1650 nm","range":"-40 dBm 至 +10 dBm","cmc":"2,5 %"}],"parameters_cs":[{"name":"1250 nm až 1650 nm","range":"-40 dBm až +10 dBm","cmc":"2,5 %"}],"technique":"Porównanie z wzorcowym miernikiem mocy optycznej","technique_en":"Comparison with an optical power meter standard","technique_zh":"与标准光功率计比较","technique_cs":"Porovnání s etalonovým měřidlem optického výkonu","techniques":["Porównanie z wzorcowym miernikiem mocy optycznej"],"techniques_en":["Comparison with an optical power meter standard"],"techniques_zh":["与标准光功率计比较"],"techniques_cs":["Porovnání s etalonovým měřidlem optického výkonu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\n1250 nm do 1650 nm od -40 dBm do +10 dBm CMC 2,5 %\nPorównanie z wzorcowym miernikiem mocy optycznej","reference":"PPKL 2.1 (ČSN EN 61315 ed. 2)","norm_bases":["PPKL 2.1","ČSN EN 61315 ed. 2"],"lab_section":"OPTOKON Malezja","lab_section_en":"OPTOKON Malaysia","lab_section_zh":"OPTOKON 马来西亚","lab_section_cs":"OPTOKON Malaysia","lab_address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 11900 Bayan Lepas, Penang, MALAYSIA","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc optyczna / optyczne analizatory widma Wzorcowanie – wielkości optyczne Porównanie z wzorcowym miernikiem mocy optycznej 1250 nm do 1650 nm od -40 dBm do +10 dBm CMC 2,5 % Optický výkon / Optické spektrální analyzátory Kalibrace – optické veličiny Porovnání s etalonovým měřidlem optického výkonu 1250 nm až 1650 nm -40 dBm až +10 dBm CMC 2,5 % PPKL 2.1 (ČSN EN 61315 ed. 2) Moc optyczna / optyczne analizatory widma Wzorcowanie – wielkosci optyczne Porownanie z wzorcowym miernikiem mocy optycznej 1250 nm do 1650 nm od -40 dBm do +10 dBm CMC 2,5 % Opticky vykon / Opticke spektralni analyzatory Kalibrace – opticke veliciny Porovnani s etalonovym meridlem optickeho vykonu 1250 nm az 1650 nm -40 dBm az +10 dBm CMC 2,5 % PPKL 2.1 (CSN EN 61315 ed. 2)","search_en":"Optical power / optical spectrum analysers Calibration – optical quantities Comparison with an optical power meter standard OPTOKON Malaysia CMC for the field of measured quantity: Optical quantities Comparison with an optical power meter standard 1250 nm to 1650 nm PPKL 2.1 (ČSN EN 61315 ed. 2)","search_zh":"光功率 / 光谱分析仪 校准 – 光学量 与标准光功率计比较 OPTOKON 马来西亚 被测量领域的CMC：光学量 与标准光功率计比较 1250 nm 至 1650 nm PPKL 2.1 (ČSN EN 61315 第2版)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Malaysia","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1250 nm bis 1650 nm","range":"von -40 dBm bis +10 dBm","cmc":"2,5 %"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Optische Leistung / optische Spektrumanalysatoren Kalibrierung – optische Größen Vergleich mit optischem Referenz-Leistungsmesser OPTOKON Malaysia CMC für den Messgrößenbereich: optische Größen Vergleich mit optischem Referenz-Leistungsmesser 1250 nm bis 1650 nm PPKL 2.1 (ČSN EN 61315 Ausg. 2)","technique_de":"Vergleich mit optischem Referenz-Leistungsmesser","techniques_de":["Vergleich mit optischem Referenz-Leistungsmesser"],"test_object_de":"Optische Leistung / optische Spektrumanalysatoren","reference_de":"PPKL 2.1 (ČSN EN 61315 Ausg. 2)","reference_zh":"PPKL 2.1 (ČSN EN 61315 第2版)","reference_pl":"PPKL 2.1 (ČSN EN 61315 wyd. 2)"},{"_id":"2ed2043c3a5f4dc1a5bb32f7","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"7","test_object":"Liniowość / optyczne analizatory widma","test_object_en":"Linearity / optical spectrum analysers","test_object_zh":"线性 / 光谱分析仪","test_object_cs":"Linearita / Optické spektrální analyzátory","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1310 nm, 1550 nm","range":"od -60 dBm do -50 dBm","cmc":"0,24 dB"},{"name":"1310 nm, 1550 nm","range":"od -50 dBm do -40 dBm","cmc":"0,09 dB"},{"name":"1310 nm, 1550 nm","range":"od -40 dBm do 0 dBm","cmc":"0,05 dB"}],"parameters_en":[{"name":"1310 nm, 1550 nm","range":"-60 dBm to -50 dBm","cmc":"0,24 dB"},{"name":"1310 nm, 1550 nm","range":"-50 dBm to -40 dBm","cmc":"0,09 dB"},{"name":"1310 nm, 1550 nm","range":"-40 dBm to 0 dBm","cmc":"0,05 dB"}],"parameters_zh":[{"name":"1310 nm, 1550 nm","range":"-60 dBm 至 -50 dBm","cmc":"0,24 dB"},{"name":"1310 nm, 1550 nm","range":"-50 dBm 至 -40 dBm","cmc":"0,09 dB"},{"name":"1310 nm, 1550 nm","range":"-40 dBm 至 0 dBm","cmc":"0,05 dB"}],"parameters_cs":[{"name":"1310 nm, 1550 nm","range":"-60 dBm až -50 dBm","cmc":"0,24 dB"},{"name":"1310 nm, 1550 nm","range":"-50 dBm až -40 dBm","cmc":"0,09 dB"},{"name":"1310 nm, 1550 nm","range":"-40 dBm až 0 dBm","cmc":"0,05 dB"}],"technique":"Porównanie z wzorcowym miernikiem mocy optycznej z użyciem tłumika optycznego","technique_en":"Comparison with an optical power meter standard using an optical attenuator","technique_zh":"借助光衰减器与标准光功率计比较","technique_cs":"Porovnání s etalonovým měřidlem optického výkonu pomocí optického atenuátoru","techniques":["Porównanie z wzorcowym miernikiem mocy optycznej z użyciem tłumika optycznego"],"techniques_en":["Comparison with an optical power meter standard using an optical attenuator"],"techniques_zh":["借助光衰减器与标准光功率计比较"],"techniques_cs":["Porovnání s etalonovým měřidlem optického výkonu pomocí optického atenuátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\n1310 nm, 1550 nm od -60 dBm do -50 dBm CMC 0,24 dB\n1310 nm, 1550 nm od -50 dBm do -40 dBm CMC 0,09 dB\n1310 nm, 1550 nm od -40 dBm do 0 dBm CMC 0,05 dB\nPorównanie z wzorcowym miernikiem mocy optycznej z użyciem tłumika optycznego","reference":"PPKL 2.6 (ČSN EN 62129-1)","norm_bases":["PPKL 2.6","ČSN EN 62129-1"],"lab_section":"OPTOKON Jihlava","lab_section_en":"OPTOKON Jihlava","lab_section_zh":"OPTOKON 伊赫拉瓦","lab_section_cs":"OPTOKON Jihlava","lab_address":"Červený Kříž 250, 586 01 Jihlava, ČR","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Liniowość / optyczne analizatory widma Wzorcowanie – wielkości optyczne Porównanie z wzorcowym miernikiem mocy optycznej z użyciem tłumika optycznego 1310 nm, 1550 nm od -60 dBm do -50 dBm CMC 0,24 dB 1310 nm, 1550 nm od -50 dBm do -40 dBm CMC 0,09 dB 1310 nm, 1550 nm od -40 dBm do 0 dBm CMC 0,05 dB Linearita / Optické spektrální analyzátory Kalibrace – optické veličiny Porovnání s etalonovým měřidlem optického výkonu pomocí optického atenuátoru 1310 nm, 1550 nm -60 dBm až -50 dBm CMC 0,24 dB 1310 nm, 1550 nm -50 dBm až -40 dBm CMC 0,09 dB 1310 nm, 1550 nm -40 dBm až 0 dBm CMC 0,05 dB PPKL 2.6 (ČSN EN 62129-1) Liniowosc / optyczne analizatory widma Wzorcowanie – wielkosci optyczne Porownanie z wzorcowym miernikiem mocy optycznej z uzyciem tlumika optycznego 1310 nm, 1550 nm od -60 dBm do -50 dBm CMC 0,24 dB 1310 nm, 1550 nm od -50 dBm do -40 dBm CMC 0,09 dB 1310 nm, 1550 nm od -40 dBm do 0 dBm CMC 0,05 dB Linearita / Opticke spektralni analyzatory Kalibrace – opticke veliciny Porovnani s etalonovym meridlem optickeho vykonu pomoci optickeho atenuatoru 1310 nm, 1550 nm -60 dBm az -50 dBm CMC 0,24 dB 1310 nm, 1550 nm -50 dBm az -40 dBm CMC 0,09 dB 1310 nm, 1550 nm -40 dBm az 0 dBm CMC 0,05 dB PPKL 2.6 (CSN EN 62129-1)","search_en":"Linearity / optical spectrum analysers Calibration – optical quantities Comparison with an optical power meter standard using an optical attenuator OPTOKON Jihlava CMC for the field of measured quantity: Optical quantities Comparison with an optical power meter standard using an optical attenuator 1310 nm, 1550 nm 1310 nm, 1550 nm 1310 nm, 1550 nm PPKL 2.6 (ČSN EN 62129-1)","search_zh":"线性 / 光谱分析仪 校准 – 光学量 借助光衰减器与标准光功率计比较 OPTOKON 伊赫拉瓦 被测量领域的CMC：光学量 借助光衰减器与标准光功率计比较 1310 nm, 1550 nm 1310 nm, 1550 nm 1310 nm, 1550 nm PPKL 2.6 (ČSN EN 62129-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Jihlava","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1310 nm, 1550 nm","range":"von -60 dBm bis -50 dBm","cmc":"0,24 dB"},{"name":"1310 nm, 1550 nm","range":"von -50 dBm bis -40 dBm","cmc":"0,09 dB"},{"name":"1310 nm, 1550 nm","range":"von -40 dBm bis 0 dBm","cmc":"0,05 dB"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Linearität / optische Spektrumanalysatoren Kalibrierung – optische Größen Vergleich mit einem Referenz-Messgerät für optische Leistung unter Verwendung eines optischen Dämpfungsglieds OPTOKON Jihlava CMC für den Messgrößenbereich: optische Größen Vergleich mit einem Referenz-Messgerät für optische Leistung unter Verwendung eines optischen Dämpfungsglieds 1310 nm, 1550 nm 1310 nm, 1550 nm 1310 nm, 1550 nm PPKL 2.6 (ČSN EN 62129-1)","technique_de":"Vergleich mit einem Referenz-Messgerät für optische Leistung unter Verwendung eines optischen Dämpfungsglieds","techniques_de":["Vergleich mit einem Referenz-Messgerät für optische Leistung unter Verwendung eines optischen Dämpfungsglieds"],"test_object_de":"Linearität / optische Spektrumanalysatoren"},{"_id":"e56d3d5392b1bcd4b3017d49","lab_id":"6acfffe3ff06824761705e10","country":"CZ","accr_number":"2315","accr_body":"ČIA","row_label":"7","test_object":"Liniowość / optyczne analizatory widma","test_object_en":"Linearity / optical spectrum analysers","test_object_zh":"线性 / 光谱分析仪","test_object_cs":"Linearita / Optické spektrální analyzátory","methodology":"Wzorcowanie – wielkości optyczne","methodology_en":"Calibration – optical quantities","methodology_zh":"校准 – 光学量","methodology_cs":"Kalibrace – optické veličiny","parameters":[{"name":"1310 nm, 1550 nm","range":"od -60 dBm do -50 dBm","cmc":"0,24 dB"},{"name":"1310 nm, 1550 nm","range":"od -50 dBm do -40 dBm","cmc":"0,09 dB"},{"name":"1310 nm, 1550 nm","range":"od -40 dBm do 0 dBm","cmc":"0,05 dB"}],"parameters_en":[{"name":"1310 nm, 1550 nm","range":"-60 dBm to -50 dBm","cmc":"0,24 dB"},{"name":"1310 nm, 1550 nm","range":"-50 dBm to -40 dBm","cmc":"0,09 dB"},{"name":"1310 nm, 1550 nm","range":"-40 dBm to 0 dBm","cmc":"0,05 dB"}],"parameters_zh":[{"name":"1310 nm, 1550 nm","range":"-60 dBm 至 -50 dBm","cmc":"0,24 dB"},{"name":"1310 nm, 1550 nm","range":"-50 dBm 至 -40 dBm","cmc":"0,09 dB"},{"name":"1310 nm, 1550 nm","range":"-40 dBm 至 0 dBm","cmc":"0,05 dB"}],"parameters_cs":[{"name":"1310 nm, 1550 nm","range":"-60 dBm až -50 dBm","cmc":"0,24 dB"},{"name":"1310 nm, 1550 nm","range":"-50 dBm až -40 dBm","cmc":"0,09 dB"},{"name":"1310 nm, 1550 nm","range":"-40 dBm až 0 dBm","cmc":"0,05 dB"}],"technique":"Porównanie z wzorcowym miernikiem mocy optycznej z użyciem tłumika optycznego","technique_en":"Comparison with an optical power meter standard using an optical attenuator","technique_zh":"借助光衰减器与标准光功率计比较","technique_cs":"Porovnání s etalonovým měřidlem optického výkonu pomocí optického atenuátoru","techniques":["Porównanie z wzorcowym miernikiem mocy optycznej z użyciem tłumika optycznego"],"techniques_en":["Comparison with an optical power meter standard using an optical attenuator"],"techniques_zh":["借助光衰减器与标准光功率计比较"],"techniques_cs":["Porovnání s etalonovým měřidlem optického výkonu pomocí optického atenuátoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości optyczne\nZakres:\n1310 nm, 1550 nm od -60 dBm do -50 dBm CMC 0,24 dB\n1310 nm, 1550 nm od -50 dBm do -40 dBm CMC 0,09 dB\n1310 nm, 1550 nm od -40 dBm do 0 dBm CMC 0,05 dB\nPorównanie z wzorcowym miernikiem mocy optycznej z użyciem tłumika optycznego","reference":"PPKL 2.6 (ČSN EN 62129-1)","norm_bases":["PPKL 2.6","ČSN EN 62129-1"],"lab_section":"OPTOKON Malezja","lab_section_en":"OPTOKON Malaysia","lab_section_zh":"OPTOKON 马来西亚","lab_section_cs":"OPTOKON Malaysia","lab_address":"303-4-25, Krystal Point, Jalan Sultan Azlan Shah, 11900 Bayan Lepas, Penang, MALAYSIA","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości optyczne","regulatory_area_en":"CMC for the field of measured quantity: Optical quantities","regulatory_area_zh":"被测量领域的CMC：光学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Optické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Liniowość / optyczne analizatory widma Wzorcowanie – wielkości optyczne Porównanie z wzorcowym miernikiem mocy optycznej z użyciem tłumika optycznego 1310 nm, 1550 nm od -60 dBm do -50 dBm CMC 0,24 dB 1310 nm, 1550 nm od -50 dBm do -40 dBm CMC 0,09 dB 1310 nm, 1550 nm od -40 dBm do 0 dBm CMC 0,05 dB Linearita / Optické spektrální analyzátory Kalibrace – optické veličiny Porovnání s etalonovým měřidlem optického výkonu pomocí optického atenuátoru 1310 nm, 1550 nm -60 dBm až -50 dBm CMC 0,24 dB 1310 nm, 1550 nm -50 dBm až -40 dBm CMC 0,09 dB 1310 nm, 1550 nm -40 dBm až 0 dBm CMC 0,05 dB PPKL 2.6 (ČSN EN 62129-1) Liniowosc / optyczne analizatory widma Wzorcowanie – wielkosci optyczne Porownanie z wzorcowym miernikiem mocy optycznej z uzyciem tlumika optycznego 1310 nm, 1550 nm od -60 dBm do -50 dBm CMC 0,24 dB 1310 nm, 1550 nm od -50 dBm do -40 dBm CMC 0,09 dB 1310 nm, 1550 nm od -40 dBm do 0 dBm CMC 0,05 dB Linearita / Opticke spektralni analyzatory Kalibrace – opticke veliciny Porovnani s etalonovym meridlem optickeho vykonu pomoci optickeho atenuatoru 1310 nm, 1550 nm -60 dBm az -50 dBm CMC 0,24 dB 1310 nm, 1550 nm -50 dBm az -40 dBm CMC 0,09 dB 1310 nm, 1550 nm -40 dBm az 0 dBm CMC 0,05 dB PPKL 2.6 (CSN EN 62129-1)","search_en":"Linearity / optical spectrum analysers Calibration – optical quantities Comparison with an optical power meter standard using an optical attenuator OPTOKON Malaysia CMC for the field of measured quantity: Optical quantities Comparison with an optical power meter standard using an optical attenuator 1310 nm, 1550 nm 1310 nm, 1550 nm 1310 nm, 1550 nm PPKL 2.6 (ČSN EN 62129-1)","search_zh":"线性 / 光谱分析仪 校准 – 光学量 借助光衰减器与标准光功率计比较 OPTOKON 马来西亚 被测量领域的CMC：光学量 借助光衰减器与标准光功率计比较 1310 nm, 1550 nm 1310 nm, 1550 nm 1310 nm, 1550 nm PPKL 2.6 (ČSN EN 62129-1)","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3","lab_section_de":"OPTOKON Malaysia","methodology_de":"Kalibrierung – optische Größen","parameters_de":[{"name":"1310 nm, 1550 nm","range":"von -60 dBm bis -50 dBm","cmc":"0,24 dB"},{"name":"1310 nm, 1550 nm","range":"von -50 dBm bis -40 dBm","cmc":"0,09 dB"},{"name":"1310 nm, 1550 nm","range":"von -40 dBm bis 0 dBm","cmc":"0,05 dB"}],"regulatory_area_de":"CMC für den Messgrößenbereich: optische Größen","search_de":"Linearität / optische Spektrumanalysatoren Kalibrierung – optische Größen Vergleich mit einem Referenz-Messgerät für optische Leistung unter Verwendung eines optischen Dämpfungsglieds OPTOKON Malaysia CMC für den Messgrößenbereich: optische Größen Vergleich mit einem Referenz-Messgerät für optische Leistung unter Verwendung eines optischen Dämpfungsglieds 1310 nm, 1550 nm 1310 nm, 1550 nm 1310 nm, 1550 nm PPKL 2.6 (ČSN EN 62129-1)","technique_de":"Vergleich mit einem Referenz-Messgerät für optische Leistung unter Verwendung eines optischen Dämpfungsglieds","techniques_de":["Vergleich mit einem Referenz-Messgerät für optische Leistung unter Verwendung eines optischen Dämpfungsglieds"],"test_object_de":"Linearität / optische Spektrumanalysatoren"}],"has_pdf":true}