🇵🇱 VEOLIA ENERGIA WARSZAWA S.A. PL
材料与高分子水与废水
VEOLIA ENERGIA WARSZAWA S.A. 是由 PCA 认可的实验室,认可编号 AB 414(Warszawa,波兰)。认可范围涵盖 109 项检测方法,涉及以下领域:材料与高分子、水与废水。检测对象包括:Pre-insulated fittingsE、Single pre-insulated pipes for the construction of water district h…、Double pre-insulated pipes for the construction of water district h…、Single pre-insulated pipes for the construction of water district c…。最常用的技术:Stereoscopic method、重量法、Method of measuring geometrical quantities。
要点速览
- 认可编号: PCA AB 414
- 认可范围内方法数: 109
- 检测对象种类: 13
- 所用技术数: 6
- 城市: Warszawa, 波兰
- 认可编号
- AB 414
- 认可机构
- PCA
- 地址
- ul. Batorego 2, 02-591 Warszawa, LABORATORIUM BADAWCZE, ul. Siemieńskiego 4
- 城市
- Warszawa, 波兰
该实验室检测什么 (13)
- Pre-insulated fittingsE — 19 项方法
- Single pre-insulated pipes for the construction of water district heating networksE — 18 项方法
- Double pre-insulated pipes for the construction of water district heating networksE — 14 项方法
- Single pre-insulated pipes for the construction of water district cooling networksE — 14 项方法
- Fibrous products, Cellular plastics E — 13 项方法
- Fibrous products, Cellular plastics — 11 项方法
- Pre-insulated joint assembly (single and double pre-insulated pipes) E — 9 项方法
- Thermoplastic plasticsE — 5 项方法
- Thermoplastic plastics — 2 项方法
- district heating — 1 项方法
- for the construction of water networks — 1 项方法
- Heat-shrinkable end capE — 1 项方法
- Single pre-insulated pipes — 1 项方法
所用检测技术 (6)
- Stereoscopic method — 6 项方法
- 重量法 — 6 项方法
- Method of measuring geometrical quantities — 4 项方法
- Method: tube apparatus — 3 项方法
- Method: plate apparatus — 2 项方法
- Method for determining gel content — 1 项方法
认可范围 — 项检测方法 (109)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | Single pre-insulated pipes for the construction of water district heating networksE | Wall thickness and outside diameter of the conduit pipe | PN-EN 253 | EN 253 | ||
| 2 | Single pre-insulated pipes for the construction of water district heating networksE | Length of uninsulated ends of conduit pipes | PN-EN 253 | EN 253 | ||
| 3 | Single pre-insulated pipes for the construction of water district heating networksE | Outside diameter and wall thickness of the sheath | PN-EN 253 | EN 253 | ||
| 4 | Single pre-insulated pipes for the construction of water district heating networksE | Elongation at break Machine range do 10 kN Tensile test |
PN-EN 253 | EN 253 | ||
| 5 | Single pre-insulated pipes for the construction of water district heating networksE | Stress cracking resistance (SCR) | PN-EN 253 | EN 253 | ||
| 6 | Single pre-insulated pipes for the construction of water district heating networksE | Cell size 范围 do 2 mm |
Stereoscopic method | PN-EN 253 | EN 253 | |
| 7 | Single pre-insulated pipes for the construction of water district heating networksE | Closed cell content, Pressure change measurement | PN-EN 253 | EN 253 | ||
| 8 | Single pre-insulated pipes for the construction of water district heating networksE | Voids and blisters, Measurement of geometrical dimensions | PN-EN 253 | EN 253 | ||
| 9 | Single pre-insulated pipes for the construction of water district heating networksE | 抗压强度 Machine range do 10 kN |
PN-EN 253 | EN 253 | ||
| 10 | Single pre-insulated pipes for the construction of water district heating networksE | Foam density | PN-EN 253 | EN 253 | ||
| 11 | Single pre-insulated pipes for the construction of water district heating networksE | Water absorption at elevated temperature | 重量法 | PN-EN 253 | EN 253 | |
| 12 | Single pre-insulated pipes for the construction of water district heating networksE | Deviation from the axis 范围 do 10 mm Pomiar wielkości geometrycznych |
PN-EN 253 | EN 253 | ||
| 13 | Single pre-insulated pipes for the construction of water district heating networksE | Shear strength in the axial direction at a temperature of 20 oC Machine range do 40 kN |
PN-EN 253 | EN 253 | ||
| 14 | Single pre-insulated pipes for the construction of water district heating networksE | Shear strength in the axial direction at a temperature of 140 oC Machine range do 40 kN |
PN-EN 253 | EN 253 | ||
| 15 | Single pre-insulated pipes for the construction of water district heating networksE | Accelerated ageing process | PN-EN 253 | EN 253 | ||
| 16 | Single pre-insulated pipes for the construction of water district heating networksE | Thermal conductivity, Range up to 0,080 W/mK | Method: tube apparatus | PN-EN 253 | EN 253 | |
| 17 | Single pre-insulated pipes for the construction of water district heating networksE | Artificial ageing process | PN-EN 253 | EN 253 | ||
| 18 | Single pre-insulated pipes for the construction of water district heating networksE | Linear watertightness | PN-EN 253 | EN 253 | ||
| 19 | Pre-insulated joint assembly (single and double pre-insulated pipes) E | Foam density | PN-EN 489-1 | EN 489-1 | ||
| 20 | Pre-insulated joint assembly (single and double pre-insulated pipes) E | 抗压强度 Machine range do 10 kN |
PN-EN 489-1 | EN 489-1 | ||
| 21 | Pre-insulated joint assembly (single and double pre-insulated pipes) E | Cell size 范围 do 2 mm |
Stereoscopic method | PN-EN 489-1 | EN 489-1 | |
| 22 | Pre-insulated joint assembly (single and double pre-insulated pipes) E | Water absorption at elevated temperature | 重量法 | PN-EN 489-1 | EN 489-1 | |
| 23 | Pre-insulated joint assembly (single and double pre-insulated pipes) E | Closed cell content, Pressure change measurement | PN-EN 489-1 | EN 489-1 | ||
| 24 | Pre-insulated joint assembly (single and double pre-insulated pipes) E | Soil load, Sand box test | PN-EN 489-1 | EN 489-1 | ||
| 25 | Pre-insulated joint assembly (single and double pre-insulated pipes) E | Watertightness | PN-EN 489-1 | EN 489-1 | ||
| 26 | Pre-insulated joint assembly (single and double pre-insulated pipes) E | Stress cracking resistance (SCR) | PN-EN 489-1 | EN 489-1 | ||
| 27 | Pre-insulated joint assembly (single and double pre-insulated pipes) E | Bend test of plugs | PN-EN 489-1 | EN 489-1 | ||
| 28 | Single pre-insulated pipes for the construction of water district cooling networksE | Wall thickness and outside diameter of the conduit pipe | PN-EN 17415-1 | EN 17415-1 | ||
| 29 | Single pre-insulated pipes for the construction of water district cooling networksE | Length of uninsulated ends of conduit pipes | PN-EN 17415-1 | EN 17415-1 | ||
| 30 | Single pre-insulated pipes for the construction of water district cooling networksE | Outside diameter and wall thickness of the sheath | PN-EN 17415-1 | EN 17415-1 | ||
| 31 | Single pre-insulated pipes for the construction of water district cooling networksE | Elongation at break Machine range do 10 kN Tensile test |
PN-EN 17415-1 | EN 17415-1 | ||
| 32 | Single pre-insulated pipes for the construction of water district cooling networksE | Stress cracking resistance (SCR) | PN-EN 17415-1 | EN 17415-1 | ||
| 33 | Single pre-insulated pipes for the construction of water district cooling networksE | Cell size 范围 do 2 mm |
Stereoscopic method | PN-EN 17415-1 | EN 17415-1 | |
| 34 | Single pre-insulated pipes for the construction of water district cooling networksE | Closed cell content, Pressure change measurement | PN-EN 17415-1 | EN 17415-1 | ||
| 35 | Single pre-insulated pipes for the construction of water district cooling networksE | Voids and blisters, Measurement of geometrical dimensions | PN-EN 17415-1 | EN 17415-1 | ||
| 36 | Single pre-insulated pipes for the construction of water district cooling networksE | 抗压强度 Machine range do 10 kN |
PN-EN 17415-1 | EN 17415-1 | ||
| 37 | Single pre-insulated pipes for the construction of water district cooling networksE | Foam density | PN-EN 17415-1 | EN 17415-1 | ||
| 38 | Single pre-insulated pipes for the construction of water district cooling networksE | Water absorption at elevated temperature | 重量法 | PN-EN 17415-1 | EN 17415-1 | |
| 39 | Single pre-insulated pipes for the construction of water district cooling networksE | Deviation from the axis 范围 do 10 mm Pomiar wielkości geometrycznych |
PN-EN 17415-1 | EN 17415-1 | ||
| 40 | Single pre-insulated pipes for the construction of water district cooling networksE | Thermal conductivity, Range up to 0,080 W/mK | Method: tube apparatus | PN-EN 17415-1 | EN 17415-1 | |
| 41 | Single pre-insulated pipes for the construction of water district cooling networksE | Linear watertightness | PN-EN 17415-1 | EN 17415-1 | ||
| 42 | Pre-insulated fittingsE | Dimensions of the pipeline pipe: Wall thickness and outside diameter | PN-EN 448 | EN 448 | ||
| 43 | Pre-insulated fittingsE | Elongation at break Machine range do 10 kN Tensile test |
PN-EN 448 | EN 448 | ||
| 44 | Pre-insulated fittingsE | Stress cracking resistance (SCR) | PN-EN 448 | EN 448 | ||
| 45 | Pre-insulated fittingsE | Cell size 范围 do 2 mm |
Stereoscopic method | PN-EN 448 | EN 448 | |
| 46 | Pre-insulated fittingsE | Closed cell content, Pressure change measurement | PN-EN 448 | EN 448 | ||
| 47 | Pre-insulated fittingsE | 抗压强度 Machine range do 10 kN |
PN-EN 448 | EN 448 | ||
| 48 | Pre-insulated fittingsE | Foam density | PN-EN 448 | EN 448 | ||
| 49 | Pre-insulated fittingsE | Water absorption at elevated temperature | 重量法 | PN-EN 448 | EN 448 | |
| 50 | Pre-insulated fittingsE | Length of the pipe sections without insulation at the ends of the fitting | PN-EN 448 | EN 448 | ||
| 51 | Pre-insulated fittingsE | Deviation from the axis at the ends of the fitting | PN-EN 448 | EN 448 | ||
| 52 | Pre-insulated fittingsE | Angular deviation of the service pipe relative to the casing at the ends of the fitting | PN-EN 448 | EN 448 | ||
| 53 | Pre-insulated fittingsE | Angle between two adjacent segments of the guard | PN-EN 448 | EN 448 | ||
| 54 | Pre-insulated fittingsE | Length of the casing segments at the ends of the fitting | PN-EN 448 | EN 448 | ||
| 55 | Pre-insulated fittingsE | Visual assessment of the joints of the enclosure | PN-EN 448 | EN 448 | ||
| 56 | Pre-insulated fittingsE | Bending of the casing connections | PN-EN 448 | EN 448 | ||
| 57 | Pre-insulated fittingsE | Dimensions of the casing: Outside diameter and wall thickness of the casing | PN-EN 448 | EN 448 | ||
| 58 | Pre-insulated fittingsE | Minimum insulation thickness | PN-EN 448 | EN 448 | ||
| 59 | Pre-insulated fittingsE | Tolerances of the main dimensions of the fitting | PN-EN 448 | EN 448 | ||
| 60 | Pre-insulated fittingsE | Guard tightness | IB-SB-19-2 | ||
| 61 | Double pre-insulated pipes for the construction of water district heating networksE | Wall thickness and outside diameter of the conduit pipe | PN-EN 15698-1 | EN 15698-1 | ||
| 62 | Double pre-insulated pipes for the construction of water district heating networksE | Length of uninsulated ends of conduit pipes | PN-EN 15698-1 | EN 15698-1 | ||
| 63 | Double pre-insulated pipes for the construction of water district heating networksE | Outside diameter and wall thickness of the sheath | PN-EN 15698-1 | EN 15698-1 | ||
| 64 | Double pre-insulated pipes for the construction of water district heating networksE | Cell size 范围 do 2 mm |
Stereoscopic method | PN-EN 15698-1 | EN 15698-1 | |
| 65 | Double pre-insulated pipes for the construction of water district heating networksE | Closed cell content, Pressure change measurement | PN-EN 15698-1 | EN 15698-1 | ||
| 66 | Double pre-insulated pipes for the construction of water district heating networksE | Voids and blisters, Measurement of geometrical dimensions | PN-EN 15698-1 | EN 15698-1 | ||
| 67 | Double pre-insulated pipes for the construction of water district heating networksE | 抗压强度 Machine range do 10 kN |
PN-EN 15698-1 | EN 15698-1 | ||
| 68 | Double pre-insulated pipes for the construction of water district heating networksE | Foam density | PN-EN 15698-1 | EN 15698-1 | ||
| 69 | Double pre-insulated pipes for the construction of water district heating networksE | Water absorption at elevated temperature | 重量法 | PN-EN 15698-1 | EN 15698-1 | |
| 70 | Double pre-insulated pipes for the construction of water district heating networksE | Alignment of the ends of pipeline pipes | PN-EN 15698-1 | EN 15698-1 | ||
| 71 | Double pre-insulated pipes for the construction of water district heating networksE | Distance between service pipes | Method of measuring geometrical quantities | PN-EN 15698-1 | EN 15698-1 | |
| 72 | Double pre-insulated pipes for the construction of water district heating networksE | Torsion of line pipes | Method of measuring geometrical quantities | PN-EN 15698-1 | EN 15698-1 | |
| 73 | Double pre-insulated pipes for the construction of water district heating networksE | Deviation from the axis | Method of measuring geometrical quantities | PN-EN 15698-1 | EN 15698-1 | |
| 74 | Double pre-insulated pipes for the construction of water district heating networksE | Shear strength in the axial direction Machine range do 40 kN |
PN-EN 15698-1 | EN 15698-1 | ||
| 75 | Fibrous products, Cellular plastics E | Thermal conductivity, Range up to 0,080 W/mK | Method: tube apparatus | PN-EN ISO 8497 | |
| 76 | Fibrous products, Cellular plastics E | Thermal conductivity 范围 do 0,080 W/mK |
Method: plate apparatus | PN-ISO 8301 | |
| 77 | Fibrous products, Cellular plastics E | 密度 | PN-EN ISO 845 | PN-EN 1602 | PN-EN ISO 18098 | ||
| 78 | Fibrous products, Cellular plastics E | 抗压强度 Machine range do 10 kN |
PN-EN ISO 29469 | PN-EN ISO 844 Metoda A | ||
| 79 | Fibrous products, Cellular plastics E | Content of closed/open cells, Pressure change measurement | PN-EN ISO 4590 Metoda 1 | ||
| 80 | Fibrous products, Cellular plastics E | Cell size 范围 do 2 mm |
Stereoscopic method | PN-EN 253 | EN 253 | |
| 81 | Fibrous products, Cellular plastics E | Water absorption at elevated temperature | 重量法 | PN-EN 253 | EN 253 | |
| 82 | Fibrous products, Cellular plastics E | 耐热性 Range of the heating chamber do 250 °C Range of the testing machine: do 10 kN |
Method of measuring geometrical quantities | PB-01 | |
| 83 | Fibrous products, Cellular plastics E | Voids and blisters | PN-EN 253 | EN 253 | ||
| 84 | Fibrous products, Cellular plastics E | Stress-strain characteristic in compression | PN-EN ISO 3386-1 | PN-EN 13941-1 | ||
| 85 | Fibrous products, Cellular plastics E | Compression set, Deformation after compression | PN-EN ISO 1856 | ISO 1856 | PN-EN 13941-1 | ||
| 86 | Fibrous products, Cellular plastics E | Linear dimensions | PN-EN ISO 1923 | ||
| 87 | Fibrous products, Cellular plastics E | Water absorption by the hydrostatic buoyancy method | PN-93/C-89084 | ISO 2896 | ||
| 88 | Thermoplastic plasticsE | Bend test | PN-EN 12814-1 | ||
| 89 | Thermoplastic plasticsE | Stress cracking resistance (SCR) | ISO 16770 | ||
| 90 | Thermoplastic plasticsE | Elongation at break | PN-EN ISO 527-1 | ||
| 91 | Thermoplastic plasticsE | Tensile strength Machine range do 10 kN |
PN-EN ISO 527-1 | ||
| 92 | Thermoplastic plasticsE | Tensile test | PN-EN ISO 527-1 | ||
| 93 | Heat-shrinkable end capE | Leak tightness | IB-SB-19-1 | IB-SB-19-2 | ||
| 94 | Thermoplastic plastics | Degree of crosslinking | Method for determining gel content | PN-EN ISO 10147:2013-06 | PN-EN 579:2001 | |
| 95 | Thermoplastic plastics | Elongation at break Tensile strength Yield strength Machine range do 10 kN Tensile test |
PN-EN ISO 6259-1:2015-05 | PN-EN ISO 6259-3:2015-08 | ||
| 96 | Fibrous products, Cellular plastics | Geometric dimensions of the insulation shell | PN-EN ISO 12628:2023-02 | ||
| 97 | Fibrous products, Cellular plastics | Dimensions and tolerances | PN-EN ISO 12628:2023-02 | ||
| 98 | Fibrous products, Cellular plastics | Linearity | PN-EN ISO 12628:2023-02 | ||
| 99 | Fibrous products, Cellular plastics | Squareness | PN-EN ISO 12628:2023-02 | ||
| 100 | Fibrous products, Cellular plastics | Maximum service temperature of pipe insulation | PN-EN ISO 18096:2023-02 | ||
| 101 | Fibrous products, Cellular plastics | 抗压强度 | PN-EN ISO 29469:2023-05 | ||
| 102 | Fibrous products, Cellular plastics | Compressive stress Machine range do 10 kN |
PN-EN ISO 29469:2023-05 | ||
| 103 | Fibrous products, Cellular plastics | Thermal resistance 范围 do 0,080 W/mK |
Method: plate apparatus | PN-EN ISO 12667:2002 | |
| 104 | Fibrous products, Cellular plastics | Elongation at break | PN-EN ISO 1798:2009 | ||
| 105 | Fibrous products, Cellular plastics | Tensile strength Machine range do 10 kN |
PN-EN ISO 1798:2009 | ||
| 106 | Fibrous products, Cellular plastics | Tensile test | PN-EN ISO 1798:2009 | ||
| 107 | Single pre-insulated pipes | Shear strength in the tangential direction Machine range do 40 kN Shear strength in the direction |
PN-EN 253+A2:2015-12 | ||
| 108 | for the construction of water networks | stycznym | PN-EN 253+A2:2015-12 | ||
| 109 | district heating | Machine range do 40 kN |
PN-EN 253+A2:2015-12 | ||
引用标准 (41)
EN 15698-1
EN 17415-1
EN 253
EN 448
EN 489-1
IB-SB-19-1
IB-SB-19-2
ISO 16770
ISO 1856
ISO 2896
PB-01
PN-93/C-89084
PN-EN 12814-1
PN-EN 13941-1
PN-EN 15698-1
PN-EN 1602
PN-EN 17415-1
PN-EN 253
PN-EN 253+A2:2015-12
PN-EN 448
PN-EN 489-1
PN-EN 579:2001
PN-EN ISO 10147:2013-06
PN-EN ISO 12628:2023-02
PN-EN ISO 12667:2002
PN-EN ISO 1798:2009
PN-EN ISO 18096:2023-02
PN-EN ISO 18098
PN-EN ISO 1856
PN-EN ISO 1923
PN-EN ISO 29469
PN-EN ISO 29469:2023-05
PN-EN ISO 3386-1
PN-EN ISO 4590 Metoda 1
PN-EN ISO 527-1
PN-EN ISO 6259-1:2015-05
PN-EN ISO 6259-3:2015-08
PN-EN ISO 844 Metoda A
PN-EN ISO 845
PN-EN ISO 8497
PN-ISO 8301