{"lab":{"_id":"69ad52a3de79e566650fb211","accr_number":"AB 414","country":"PL","accr_body":"PCA","address":"ul. Batorego 2, 02-591 Warszawa, LABORATORIUM BADAWCZE, ul. Siemieńskiego 4","categories":["materials","water"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":109,"name":"VEOLIA ENERGIA WARSZAWA S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_414.pdf"],"scope_summary":"","search_text":"veolia energia warszawa s.a. ul. batorego 2, 02-591 warszawa, laboratorium badawcze, ul. siemieńskiego 4 other materials metrology water","status":"active","updated_at":"2026-03-08T14:51:14.968Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:14.968Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20414,podmiot.html","fields_of_testing":[{"codes":"J/8; J/21","pl":"Badania mechaniczne wyrobów i materiałów konstrukcyjnych, wyrobów z tworzyw sztucznych","en":"Mechanical tests of structural materials and products, plastic products"},{"codes":"N/8; N/21","pl":"Badania właściwości fizycznych wyrobów i materiałów konstrukcyjnych, wyrobów z tworzyw sztucznych","en":"Physical properties tests of structural materials and products, plastic products"},{"codes":"C/21","pl":"Badania chemiczne wyrobów z tworzyw sztucznych","en":"Chemical tests of plastic products"}],"issue":{"no":"24","date":"18.12.2025"},"parse_date":"2026-07-20T07:09:37.644Z","parse_source":"script-pdfplumber","map_coord":[52.212588,21.014671],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":71,"materials":31,"water":7,"construction":2},"category_scores":{"other":45.41,"materials":8.66,"water":0.44,"construction":0.04},"has_zh":true},"methods":[{"_id":"6a5dc9b1f1c10c8ce825bb49","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Grubość i średnica zewnętrzna ścianki rury przewodowej","methodology_en":"Wall thickness and outside diameter of the conduit pipe","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość i średnica zewnętrzna ścianki rury przewodowej","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Grubość i średnica zewnętrzna ścianki rury przewodowej PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Grubosc i srednica zewnetrzna scianki rury przewodowej PN-EN 253 | EN 253","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Wall thickness and outside diameter of the conduit pipe PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb4a","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Długość nieizolowanych końców rur przewodowych","methodology_en":"Length of uninsulated ends of conduit pipes","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość nieizolowanych końców rur przewodowych","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Długość nieizolowanych końców rur przewodowych PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Dlugosc nieizolowanych koncow rur przewodowych PN-EN 253 | EN 253","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Length of uninsulated ends of conduit pipes PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb4b","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Średnica zewnętrzna i grubość ścianki osłony","methodology_en":"Outside diameter and wall thickness of the sheath","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica zewnętrzna i grubość ścianki osłony","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Średnica zewnętrzna i grubość ścianki osłony PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Srednica zewnetrzna i grubosc scianki oslony PN-EN 253 | EN 253","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Outside diameter and wall thickness of the sheath PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb4c","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Wydłużenie przy zerwaniu","methodology_en":"Elongation at break","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"},{"name":"Próba rozciągania"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"},{"name":"Tensile test"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie przy zerwaniu\nZakres:\nZakres maszyny do 10 kN\nPróba rozciągania","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Wydłużenie przy zerwaniu\nZakres:\nZakres maszyny do 10 kN\nPróba rozciągania PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Wydluzenie przy zerwaniu\nZakres:\nZakres maszyny do 10 kN\nProba rozciagania PN-EN 253 | EN 253","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Elongation at break Machine range Tensile test PN-EN 253 | EN 253","parameters_zh":[{"name":"机器量程","range":"do 10 kN"},{"name":"拉伸试验"}],"search_zh":"用于建设热水管网的单管预制保温管道E 断裂伸长率 机器量程 拉伸试验 PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E","methodology_zh":"断裂伸长率"},{"_id":"6a5dc9b1f1c10c8ce825bb4d","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Odporność na pękanie naprężeniowe (SCR)","methodology_en":"Stress cracking resistance (SCR)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pękanie naprężeniowe (SCR)","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Odporność na pękanie naprężeniowe (SCR) PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Odpornosc na pekanie naprezeniowe (SCR) PN-EN 253 | EN 253","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Stress cracking resistance (SCR) PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E 耐应力开裂性（SCR） PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E","methodology_zh":"耐应力开裂性（SCR）"},{"_id":"6a5dc9b1f1c10c8ce825bb4e","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Wymiar komórki","methodology_en":"Cell size","parameters":[{"name":"Zakres","range":"do 2 mm"}],"parameters_en":[{"name":"Range","range":"do 2 mm"}],"technique":"Metoda stereoskopowa","techniques":["Metoda stereoskopowa"],"technique_en":"Stereoscopic method","computed":[],"computed_en":[],"activity":"Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Wymiar komorki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 253 | EN 253","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Cell size Stereoscopic method Range PN-EN 253 | EN 253","parameters_zh":[{"name":"范围","range":"do 2 mm"}],"search_zh":"用于建设热水管网的单管预制保温管道E 孔室尺寸 体视显微镜法 范围 PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E","methodology_zh":"孔室尺寸","technique_zh":"体视显微镜法"},{"_id":"6a5dc9b1f1c10c8ce825bb4f","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Udział komórek zamkniętych, Pomiar zmiany ciśnienia","methodology_en":"Closed cell content, Pressure change measurement","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Udział komórek zamkniętych, Pomiar zmiany ciśnienia","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Udział komórek zamkniętych, Pomiar zmiany ciśnienia PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Udzial komorek zamknietych, Pomiar zmiany cisnienia PN-EN 253 | EN 253","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Closed cell content, Pressure change measurement PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E 闭孔率，压力变化测量 PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E","methodology_zh":"闭孔率，压力变化测量"},{"_id":"6a5dc9b1f1c10c8ce825bb50","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Puste przestrzenie i pęcherze, Pomiar wielkości geometrycznych","methodology_en":"Voids and blisters, Measurement of geometrical dimensions","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Puste przestrzenie i pęcherze, Pomiar wielkości geometrycznych","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Puste przestrzenie i pęcherze, Pomiar wielkości geometrycznych PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Puste przestrzenie i pecherze, Pomiar wielkosci geometrycznych PN-EN 253 | EN 253","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Voids and blisters, Measurement of geometrical dimensions PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb51","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres maszyny do 10 kN","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Wytrzymałość na ściskanie\nZakres maszyny do 10 kN PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Wytrzymalosc na sciskanie\nZakres maszyny do 10 kN PN-EN 253 | EN 253","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Compressive strength Machine range PN-EN 253 | EN 253","methodology_zh":"抗压强度","search_zh":"用于建设热水管网的单管预制保温管道E 抗压强度 机器量程 PN-EN 253 | EN 253","parameters_zh":[{"name":"机器量程","range":"do 10 kN"}],"test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb52","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Gęstość pianki","methodology_en":"Foam density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość pianki","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Gęstość pianki PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Gestosc pianki PN-EN 253 | EN 253","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Foam density PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E 泡沫密度 PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E","methodology_zh":"泡沫密度"},{"_id":"6a5dc9b1f1c10c8ce825bb53","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Chłonność wody w podwyższonej temperaturze","methodology_en":"Water absorption at elevated temperature","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Chłonność wody w podwyższonej temperaturze\nMetoda wagowa","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Chłonność wody w podwyższonej temperaturze\nMetoda wagowa PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Chlonnosc wody w podwyzszonej temperaturze\nMetoda wagowa PN-EN 253 | EN 253","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Water absorption at elevated temperature Gravimetric method PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E 高温下的吸水性 重量法 PN-EN 253 | EN 253","technique_zh":"重量法","test_object_zh":"用于建设热水管网的单管预制保温管道E","methodology_zh":"高温下的吸水性"},{"_id":"6a5dc9b1f1c10c8ce825bb54","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Odchylenie od osi","methodology_en":"Deviation from the axis","parameters":[{"name":"Zakres","range":"do 10 mm"},{"name":"Pomiar wielkości geometrycznych"}],"parameters_en":[{"name":"Range","range":"do 10 mm"},{"name":"Measurement of geometrical quantities"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odchylenie od osi\nZakres:\nZakres do 10 mm\nPomiar wielkości geometrycznych","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Odchylenie od osi\nZakres:\nZakres do 10 mm\nPomiar wielkości geometrycznych PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Odchylenie od osi\nZakres:\nZakres do 10 mm\nPomiar wielkosci geometrycznych PN-EN 253 | EN 253","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Deviation from the axis Range Measurement of geometrical quantities PN-EN 253 | EN 253","parameters_zh":[{"name":"范围","range":"do 10 mm"},{"name":"几何量测量"}],"search_zh":"用于建设热水管网的单管预制保温管道E 范围 几何量测量 PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb55","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Wytrzymałość na ścinanie w kierunku osiowym w temperaturze 20 oC","methodology_en":"Shear strength in the axial direction at a temperature of 20 oC","parameters":[{"name":"Zakres maszyny","range":"do 40 kN"}],"parameters_en":[{"name":"Machine range","range":"do 40 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie w kierunku osiowym w temperaturze 20 oC\nZakres maszyny do 40 kN","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Wytrzymałość na ścinanie w kierunku osiowym w temperaturze 20 oC\nZakres maszyny do 40 kN PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Wytrzymalosc na scinanie w kierunku osiowym w temperaturze 20 oC\nZakres maszyny do 40 kN PN-EN 253 | EN 253","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Shear strength in the axial direction at a temperature of 20 oC Machine range PN-EN 253 | EN 253","parameters_zh":[{"name":"机器量程","range":"do 40 kN"}],"search_zh":"用于建设热水管网的单管预制保温管道E 机器量程 PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb56","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Wytrzymałość na ścinanie w kierunku osiowym w temperaturze 140 oC","methodology_en":"Shear strength in the axial direction at a temperature of 140 oC","parameters":[{"name":"Zakres maszyny","range":"do 40 kN"}],"parameters_en":[{"name":"Machine range","range":"do 40 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie w kierunku osiowym w temperaturze 140 oC\nZakres maszyny do 40 kN","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Wytrzymałość na ścinanie w kierunku osiowym w temperaturze 140 oC\nZakres maszyny do 40 kN PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Wytrzymalosc na scinanie w kierunku osiowym w temperaturze 140 oC\nZakres maszyny do 40 kN PN-EN 253 | EN 253","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Shear strength in the axial direction at a temperature of 140 oC Machine range PN-EN 253 | EN 253","parameters_zh":[{"name":"机器量程","range":"do 40 kN"}],"search_zh":"用于建设热水管网的单管预制保温管道E 机器量程 PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb57","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Proces przyspieszonego starzenia","methodology_en":"Accelerated ageing process","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Proces przyspieszonego starzenia","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Proces przyspieszonego starzenia PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Proces przyspieszonego starzenia PN-EN 253 | EN 253","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Accelerated ageing process PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb58","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Przewodność cieplna, Zakres do 0,080 W/mK","methodology_en":"Thermal conductivity, Range up to 0,080 W/mK","parameters":[],"parameters_en":[],"technique":"Metoda: aparat rurowy","techniques":["Metoda: aparat rurowy"],"technique_en":"Method: tube apparatus","computed":[],"computed_en":[],"activity":"Przewodność cieplna, Zakres do 0,080 W/mK\nMetoda: aparat rurowy","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Przewodność cieplna, Zakres do 0,080 W/mK\nMetoda: aparat rurowy PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Przewodnosc cieplna, Zakres do 0,080 W/mK\nMetoda: aparat rurowy PN-EN 253 | EN 253","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Thermal conductivity, Range up to 0,080 W/mK Method: tube apparatus PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb59","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Proces sztucznego starzenia","methodology_en":"Artificial ageing process","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Proces sztucznego starzenia","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Proces sztucznego starzenia PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Proces sztucznego starzenia PN-EN 253 | EN 253","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Artificial ageing process PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb5a","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE","test_object_en":"Single pre-insulated pipes for the construction of water district heating networksE","methodology":"Wodoszczelność liniowa","methodology_en":"Linear watertightness","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność liniowa","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci ciepłowniczychE Wodoszczelność liniowa PN-EN 253 | EN 253 Rury preizolowane pojedyncze do budowy wodnych sieci cieplowniczychE Wodoszczelnosc liniowa PN-EN 253 | EN 253","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district heating networksE Linear watertightness PN-EN 253 | EN 253","search_zh":"用于建设热水管网的单管预制保温管道E PN-EN 253 | EN 253","test_object_zh":"用于建设热水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb5b","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E","test_object_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E","methodology":"Gęstość pianki","methodology_en":"Foam density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość pianki","reference":"PN-EN 489-1 | EN 489-1","norm_bases":["PN-EN 489-1","EN 489-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E Gęstość pianki PN-EN 489-1 | EN 489-1 Zespol zlacza preizolowanego (rury preizolowane pojedyncze i podwojne) E Gestosc pianki PN-EN 489-1 | EN 489-1","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E Foam density PN-EN 489-1 | EN 489-1","search_zh":"预制保温接头组件（单管与双管预制保温管道）E 泡沫密度 PN-EN 489-1 | EN 489-1","test_object_zh":"预制保温接头组件（单管与双管预制保温管道）E","methodology_zh":"泡沫密度"},{"_id":"6a5dc9b1f1c10c8ce825bb5c","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E","test_object_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres maszyny do 10 kN","reference":"PN-EN 489-1 | EN 489-1","norm_bases":["PN-EN 489-1","EN 489-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E Wytrzymałość na ściskanie\nZakres maszyny do 10 kN PN-EN 489-1 | EN 489-1 Zespol zlacza preizolowanego (rury preizolowane pojedyncze i podwojne) E Wytrzymalosc na sciskanie\nZakres maszyny do 10 kN PN-EN 489-1 | EN 489-1","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E Compressive strength Machine range PN-EN 489-1 | EN 489-1","methodology_zh":"抗压强度","search_zh":"预制保温接头组件（单管与双管预制保温管道）E 抗压强度 机器量程 PN-EN 489-1 | EN 489-1","parameters_zh":[{"name":"机器量程","range":"do 10 kN"}],"test_object_zh":"预制保温接头组件（单管与双管预制保温管道）E"},{"_id":"6a5dc9b1f1c10c8ce825bb5d","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E","test_object_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E","methodology":"Wymiar komórki","methodology_en":"Cell size","parameters":[{"name":"Zakres","range":"do 2 mm"}],"parameters_en":[{"name":"Range","range":"do 2 mm"}],"technique":"Metoda stereoskopowa","techniques":["Metoda stereoskopowa"],"technique_en":"Stereoscopic method","computed":[],"computed_en":[],"activity":"Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa","reference":"PN-EN 489-1 | EN 489-1","norm_bases":["PN-EN 489-1","EN 489-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 489-1 | EN 489-1 Zespol zlacza preizolowanego (rury preizolowane pojedyncze i podwojne) E Wymiar komorki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 489-1 | EN 489-1","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E Cell size Stereoscopic method Range PN-EN 489-1 | EN 489-1","parameters_zh":[{"name":"范围","range":"do 2 mm"}],"search_zh":"预制保温接头组件（单管与双管预制保温管道）E 孔室尺寸 体视显微镜法 范围 PN-EN 489-1 | EN 489-1","test_object_zh":"预制保温接头组件（单管与双管预制保温管道）E","methodology_zh":"孔室尺寸","technique_zh":"体视显微镜法"},{"_id":"6a5dc9b1f1c10c8ce825bb5e","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E","test_object_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E","methodology":"Chłonność wody w podwyższonej temperaturze","methodology_en":"Water absorption at elevated temperature","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Chłonność wody w podwyższonej temperaturze\nMetoda wagowa","reference":"PN-EN 489-1 | EN 489-1","norm_bases":["PN-EN 489-1","EN 489-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E Chłonność wody w podwyższonej temperaturze\nMetoda wagowa PN-EN 489-1 | EN 489-1 Zespol zlacza preizolowanego (rury preizolowane pojedyncze i podwojne) E Chlonnosc wody w podwyzszonej temperaturze\nMetoda wagowa PN-EN 489-1 | EN 489-1","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E Water absorption at elevated temperature Gravimetric method PN-EN 489-1 | EN 489-1","search_zh":"预制保温接头组件（单管与双管预制保温管道）E 高温下的吸水性 重量法 PN-EN 489-1 | EN 489-1","technique_zh":"重量法","test_object_zh":"预制保温接头组件（单管与双管预制保温管道）E","methodology_zh":"高温下的吸水性"},{"_id":"6a5dc9b1f1c10c8ce825bb5f","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E","test_object_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E","methodology":"Udział komórek zamkniętych, Pomiar zmiany ciśnienia","methodology_en":"Closed cell content, Pressure change measurement","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Udział komórek zamkniętych, Pomiar zmiany ciśnienia","reference":"PN-EN 489-1 | EN 489-1","norm_bases":["PN-EN 489-1","EN 489-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E Udział komórek zamkniętych, Pomiar zmiany ciśnienia PN-EN 489-1 | EN 489-1 Zespol zlacza preizolowanego (rury preizolowane pojedyncze i podwojne) E Udzial komorek zamknietych, Pomiar zmiany cisnienia PN-EN 489-1 | EN 489-1","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E Closed cell content, Pressure change measurement PN-EN 489-1 | EN 489-1","search_zh":"预制保温接头组件（单管与双管预制保温管道）E 闭孔率，压力变化测量 PN-EN 489-1 | EN 489-1","test_object_zh":"预制保温接头组件（单管与双管预制保温管道）E","methodology_zh":"闭孔率，压力变化测量"},{"_id":"6a5dc9b1f1c10c8ce825bb60","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E","test_object_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E","methodology":"Obciążenie od gruntu, Test w skrzyni z piaskiem","methodology_en":"Soil load, Sand box test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie od gruntu, Test w skrzyni z piaskiem","reference":"PN-EN 489-1 | EN 489-1","norm_bases":["PN-EN 489-1","EN 489-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E Obciążenie od gruntu, Test w skrzyni z piaskiem PN-EN 489-1 | EN 489-1 Zespol zlacza preizolowanego (rury preizolowane pojedyncze i podwojne) E Obciazenie od gruntu, Test w skrzyni z piaskiem PN-EN 489-1 | EN 489-1","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E Soil load, Sand box test PN-EN 489-1 | EN 489-1","search_zh":"预制保温接头组件（单管与双管预制保温管道）E PN-EN 489-1 | EN 489-1","test_object_zh":"预制保温接头组件（单管与双管预制保温管道）E"},{"_id":"6a5dc9b1f1c10c8ce825bb61","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E","test_object_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E","methodology":"Wodoszczelność","methodology_en":"Watertightness","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność","reference":"PN-EN 489-1 | EN 489-1","norm_bases":["PN-EN 489-1","EN 489-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E Wodoszczelność PN-EN 489-1 | EN 489-1 Zespol zlacza preizolowanego (rury preizolowane pojedyncze i podwojne) E Wodoszczelnosc PN-EN 489-1 | EN 489-1","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E Watertightness PN-EN 489-1 | EN 489-1","methodology_zh":"不透水性","search_zh":"预制保温接头组件（单管与双管预制保温管道）E 不透水性 PN-EN 489-1 | EN 489-1","test_object_zh":"预制保温接头组件（单管与双管预制保温管道）E"},{"_id":"6a5dc9b1f1c10c8ce825bb62","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E","test_object_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E","methodology":"Odporność na pękanie naprężeniowe (SCR)","methodology_en":"Stress cracking resistance (SCR)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pękanie naprężeniowe (SCR)","reference":"PN-EN 489-1 | EN 489-1","norm_bases":["PN-EN 489-1","EN 489-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E Odporność na pękanie naprężeniowe (SCR) PN-EN 489-1 | EN 489-1 Zespol zlacza preizolowanego (rury preizolowane pojedyncze i podwojne) E Odpornosc na pekanie naprezeniowe (SCR) PN-EN 489-1 | EN 489-1","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E Stress cracking resistance (SCR) PN-EN 489-1 | EN 489-1","search_zh":"预制保温接头组件（单管与双管预制保温管道）E 耐应力开裂性（SCR） PN-EN 489-1 | EN 489-1","test_object_zh":"预制保温接头组件（单管与双管预制保温管道）E","methodology_zh":"耐应力开裂性（SCR）"},{"_id":"6a5dc9b1f1c10c8ce825bb63","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E","test_object_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E","methodology":"Próba zginania korków","methodology_en":"Bend test of plugs","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba zginania korków","reference":"PN-EN 489-1 | EN 489-1","norm_bases":["PN-EN 489-1","EN 489-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zespół złącza preizolowanego (rury preizolowane pojedyncze i podwójne) E Próba zginania korków PN-EN 489-1 | EN 489-1 Zespol zlacza preizolowanego (rury preizolowane pojedyncze i podwojne) E Proba zginania korkow PN-EN 489-1 | EN 489-1","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated joint assembly (single and double pre-insulated pipes) E Bend test of plugs PN-EN 489-1 | EN 489-1","search_zh":"预制保温接头组件（单管与双管预制保温管道）E PN-EN 489-1 | EN 489-1","test_object_zh":"预制保温接头组件（单管与双管预制保温管道）E"},{"_id":"6a5dc9b1f1c10c8ce825bb64","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Grubość i średnica zewnętrzna ścianki rury przewodowej","methodology_en":"Wall thickness and outside diameter of the conduit pipe","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość i średnica zewnętrzna ścianki rury przewodowej","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Grubość i średnica zewnętrzna ścianki rury przewodowej PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Grubosc i srednica zewnetrzna scianki rury przewodowej PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Wall thickness and outside diameter of the conduit pipe PN-EN 17415-1 | EN 17415-1","search_zh":"用于建设区域供冷水管网的单管预制保温管道E PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb65","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Długość nieizolowanych końców rur przewodowych","methodology_en":"Length of uninsulated ends of conduit pipes","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość nieizolowanych końców rur przewodowych","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Długość nieizolowanych końców rur przewodowych PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Dlugosc nieizolowanych koncow rur przewodowych PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Length of uninsulated ends of conduit pipes PN-EN 17415-1 | EN 17415-1","search_zh":"用于建设区域供冷水管网的单管预制保温管道E PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb66","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Średnica zewnętrzna i grubość ścianki osłony","methodology_en":"Outside diameter and wall thickness of the sheath","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica zewnętrzna i grubość ścianki osłony","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Średnica zewnętrzna i grubość ścianki osłony PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Srednica zewnetrzna i grubosc scianki oslony PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Outside diameter and wall thickness of the sheath PN-EN 17415-1 | EN 17415-1","search_zh":"用于建设区域供冷水管网的单管预制保温管道E PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb67","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Wydłużenie przy zerwaniu","methodology_en":"Elongation at break","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"},{"name":"Próba rozciągania"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"},{"name":"Tensile test"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie przy zerwaniu\nZakres:\nZakres maszyny do 10 kN\nPróba rozciągania","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Wydłużenie przy zerwaniu\nZakres:\nZakres maszyny do 10 kN\nPróba rozciągania PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Wydluzenie przy zerwaniu\nZakres:\nZakres maszyny do 10 kN\nProba rozciagania PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Elongation at break Machine range Tensile test PN-EN 17415-1 | EN 17415-1","parameters_zh":[{"name":"机器量程","range":"do 10 kN"},{"name":"拉伸试验"}],"search_zh":"用于建设区域供冷水管网的单管预制保温管道E 断裂伸长率 机器量程 拉伸试验 PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E","methodology_zh":"断裂伸长率"},{"_id":"6a5dc9b1f1c10c8ce825bb68","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Odporność na pękanie naprężeniowe (SCR)","methodology_en":"Stress cracking resistance (SCR)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pękanie naprężeniowe (SCR)","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Odporność na pękanie naprężeniowe (SCR) PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Odpornosc na pekanie naprezeniowe (SCR) PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Stress cracking resistance (SCR) PN-EN 17415-1 | EN 17415-1","search_zh":"用于建设区域供冷水管网的单管预制保温管道E 耐应力开裂性（SCR） PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E","methodology_zh":"耐应力开裂性（SCR）"},{"_id":"6a5dc9b1f1c10c8ce825bb69","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Wymiar komórki","methodology_en":"Cell size","parameters":[{"name":"Zakres","range":"do 2 mm"}],"parameters_en":[{"name":"Range","range":"do 2 mm"}],"technique":"Metoda stereoskopowa","techniques":["Metoda stereoskopowa"],"technique_en":"Stereoscopic method","computed":[],"computed_en":[],"activity":"Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Wymiar komorki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Cell size Stereoscopic method Range PN-EN 17415-1 | EN 17415-1","parameters_zh":[{"name":"范围","range":"do 2 mm"}],"search_zh":"用于建设区域供冷水管网的单管预制保温管道E 孔室尺寸 体视显微镜法 范围 PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E","methodology_zh":"孔室尺寸","technique_zh":"体视显微镜法"},{"_id":"6a5dc9b1f1c10c8ce825bb6a","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Udział komórek zamkniętych, Pomiar zmiany ciśnienia","methodology_en":"Closed cell content, Pressure change measurement","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Udział komórek zamkniętych, Pomiar zmiany ciśnienia","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Udział komórek zamkniętych, Pomiar zmiany ciśnienia PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Udzial komorek zamknietych, Pomiar zmiany cisnienia PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Closed cell content, Pressure change measurement PN-EN 17415-1 | EN 17415-1","search_zh":"用于建设区域供冷水管网的单管预制保温管道E 闭孔率，压力变化测量 PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E","methodology_zh":"闭孔率，压力变化测量"},{"_id":"6a5dc9b1f1c10c8ce825bb6b","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Puste przestrzenie i pęcherze, Pomiar wielkości geometrycznych","methodology_en":"Voids and blisters, Measurement of geometrical dimensions","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Puste przestrzenie i pęcherze, Pomiar wielkości geometrycznych","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Puste przestrzenie i pęcherze, Pomiar wielkości geometrycznych PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Puste przestrzenie i pecherze, Pomiar wielkosci geometrycznych PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Voids and blisters, Measurement of geometrical dimensions PN-EN 17415-1 | EN 17415-1","search_zh":"用于建设区域供冷水管网的单管预制保温管道E PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb6c","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres maszyny do 10 kN","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Wytrzymałość na ściskanie\nZakres maszyny do 10 kN PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Wytrzymalosc na sciskanie\nZakres maszyny do 10 kN PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Compressive strength Machine range PN-EN 17415-1 | EN 17415-1","methodology_zh":"抗压强度","search_zh":"用于建设区域供冷水管网的单管预制保温管道E 抗压强度 机器量程 PN-EN 17415-1 | EN 17415-1","parameters_zh":[{"name":"机器量程","range":"do 10 kN"}],"test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb6d","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Gęstość pianki","methodology_en":"Foam density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość pianki","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Gęstość pianki PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Gestosc pianki PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Foam density PN-EN 17415-1 | EN 17415-1","search_zh":"用于建设区域供冷水管网的单管预制保温管道E 泡沫密度 PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E","methodology_zh":"泡沫密度"},{"_id":"6a5dc9b1f1c10c8ce825bb6e","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Chłonność wody w podwyższonej temperaturze","methodology_en":"Water absorption at elevated temperature","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Chłonność wody w podwyższonej temperaturze\nMetoda wagowa","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Chłonność wody w podwyższonej temperaturze\nMetoda wagowa PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Chlonnosc wody w podwyzszonej temperaturze\nMetoda wagowa PN-EN 17415-1 | EN 17415-1","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Water absorption at elevated temperature Gravimetric method PN-EN 17415-1 | EN 17415-1","search_zh":"用于建设区域供冷水管网的单管预制保温管道E 高温下的吸水性 重量法 PN-EN 17415-1 | EN 17415-1","technique_zh":"重量法","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E","methodology_zh":"高温下的吸水性"},{"_id":"6a5dc9b1f1c10c8ce825bb6f","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Odchylenie od osi","methodology_en":"Deviation from the axis","parameters":[{"name":"Zakres","range":"do 10 mm"},{"name":"Pomiar wielkości geometrycznych"}],"parameters_en":[{"name":"Range","range":"do 10 mm"},{"name":"Measurement of geometrical quantities"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odchylenie od osi\nZakres:\nZakres do 10 mm\nPomiar wielkości geometrycznych","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Odchylenie od osi\nZakres:\nZakres do 10 mm\nPomiar wielkości geometrycznych PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Odchylenie od osi\nZakres:\nZakres do 10 mm\nPomiar wielkosci geometrycznych PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Deviation from the axis Range Measurement of geometrical quantities PN-EN 17415-1 | EN 17415-1","parameters_zh":[{"name":"范围","range":"do 10 mm"},{"name":"几何量测量"}],"search_zh":"用于建设区域供冷水管网的单管预制保温管道E 范围 几何量测量 PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb70","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Przewodność cieplna, Zakres do 0,080 W/mK","methodology_en":"Thermal conductivity, Range up to 0,080 W/mK","parameters":[],"parameters_en":[],"technique":"Metoda: aparat rurowy","techniques":["Metoda: aparat rurowy"],"technique_en":"Method: tube apparatus","computed":[],"computed_en":[],"activity":"Przewodność cieplna, Zakres do 0,080 W/mK\nMetoda: aparat rurowy","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Przewodność cieplna, Zakres do 0,080 W/mK\nMetoda: aparat rurowy PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Przewodnosc cieplna, Zakres do 0,080 W/mK\nMetoda: aparat rurowy PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Thermal conductivity, Range up to 0,080 W/mK Method: tube apparatus PN-EN 17415-1 | EN 17415-1","search_zh":"用于建设区域供冷水管网的单管预制保温管道E PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb71","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE","test_object_en":"Single pre-insulated pipes for the construction of water district cooling networksE","methodology":"Wodoszczelność liniowa","methodology_en":"Linear watertightness","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność liniowa","reference":"PN-EN 17415-1 | EN 17415-1","norm_bases":["PN-EN 17415-1","EN 17415-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze do budowy wodnych sieci chłodu systemowegoE Wodoszczelność liniowa PN-EN 17415-1 | EN 17415-1 Rury preizolowane pojedyncze do budowy wodnych sieci chlodu systemowegoE Wodoszczelnosc liniowa PN-EN 17415-1 | EN 17415-1","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes for the construction of water district cooling networksE Linear watertightness PN-EN 17415-1 | EN 17415-1","search_zh":"用于建设区域供冷水管网的单管预制保温管道E PN-EN 17415-1 | EN 17415-1","test_object_zh":"用于建设区域供冷水管网的单管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb72","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Wymiary rury przewodowej: Grubość i średnica zewnętrzna ścianki","methodology_en":"Dimensions of the pipeline pipe: Wall thickness and outside diameter","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary rury przewodowej: Grubość i średnica zewnętrzna ścianki","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Wymiary rury przewodowej: Grubość i średnica zewnętrzna ścianki PN-EN 448 | EN 448 Ksztaltki preizolowaneE Wymiary rury przewodowej: Grubosc i srednica zewnetrzna scianki PN-EN 448 | EN 448","categories":["other"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Dimensions of the pipeline pipe: Wall thickness and outside diameter PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb73","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Wydłużenie przy zerwaniu","methodology_en":"Elongation at break","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"},{"name":"Próba rozciągania"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"},{"name":"Tensile test"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie przy zerwaniu\nZakres:\nZakres maszyny do 10 kN\nPróba rozciągania","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Wydłużenie przy zerwaniu\nZakres:\nZakres maszyny do 10 kN\nPróba rozciągania PN-EN 448 | EN 448 Ksztaltki preizolowaneE Wydluzenie przy zerwaniu\nZakres:\nZakres maszyny do 10 kN\nProba rozciagania PN-EN 448 | EN 448","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Elongation at break Machine range Tensile test PN-EN 448 | EN 448","parameters_zh":[{"name":"机器量程","range":"do 10 kN"},{"name":"拉伸试验"}],"search_zh":"预制保温管件 E 断裂伸长率 机器量程 拉伸试验 PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E","methodology_zh":"断裂伸长率"},{"_id":"6a5dc9b1f1c10c8ce825bb74","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Odporność na pękanie naprężeniowe (SCR)","methodology_en":"Stress cracking resistance (SCR)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pękanie naprężeniowe (SCR)","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Odporność na pękanie naprężeniowe (SCR) PN-EN 448 | EN 448 Ksztaltki preizolowaneE Odpornosc na pekanie naprezeniowe (SCR) PN-EN 448 | EN 448","categories":["other"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Stress cracking resistance (SCR) PN-EN 448 | EN 448","search_zh":"预制保温管件 E 耐应力开裂性（SCR） PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E","methodology_zh":"耐应力开裂性（SCR）"},{"_id":"6a5dc9b1f1c10c8ce825bb75","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Wymiar komórki","methodology_en":"Cell size","parameters":[{"name":"Zakres","range":"do 2 mm"}],"parameters_en":[{"name":"Range","range":"do 2 mm"}],"technique":"Metoda stereoskopowa","techniques":["Metoda stereoskopowa"],"technique_en":"Stereoscopic method","computed":[],"computed_en":[],"activity":"Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 448 | EN 448 Ksztaltki preizolowaneE Wymiar komorki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 448 | EN 448","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Cell size Stereoscopic method Range PN-EN 448 | EN 448","parameters_zh":[{"name":"范围","range":"do 2 mm"}],"search_zh":"预制保温管件 E 孔室尺寸 体视显微镜法 范围 PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E","methodology_zh":"孔室尺寸","technique_zh":"体视显微镜法"},{"_id":"6a5dc9b1f1c10c8ce825bb76","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Udział komórek zamkniętych, Pomiar zmiany ciśnienia","methodology_en":"Closed cell content, Pressure change measurement","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Udział komórek zamkniętych, Pomiar zmiany ciśnienia","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Udział komórek zamkniętych, Pomiar zmiany ciśnienia PN-EN 448 | EN 448 Ksztaltki preizolowaneE Udzial komorek zamknietych, Pomiar zmiany cisnienia PN-EN 448 | EN 448","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Closed cell content, Pressure change measurement PN-EN 448 | EN 448","search_zh":"预制保温管件 E 闭孔率，压力变化测量 PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E","methodology_zh":"闭孔率，压力变化测量"},{"_id":"6a5dc9b1f1c10c8ce825bb77","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres maszyny do 10 kN","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Wytrzymałość na ściskanie\nZakres maszyny do 10 kN PN-EN 448 | EN 448 Ksztaltki preizolowaneE Wytrzymalosc na sciskanie\nZakres maszyny do 10 kN PN-EN 448 | EN 448","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Compressive strength Machine range PN-EN 448 | EN 448","methodology_zh":"抗压强度","search_zh":"预制保温管件 E 抗压强度 机器量程 PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E","parameters_zh":[{"name":"机器量程","range":"do 10 kN"}]},{"_id":"6a5dc9b1f1c10c8ce825bb78","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Gęstość pianki","methodology_en":"Foam density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość pianki","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Gęstość pianki PN-EN 448 | EN 448 Ksztaltki preizolowaneE Gestosc pianki PN-EN 448 | EN 448","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Foam density PN-EN 448 | EN 448","search_zh":"预制保温管件 E 泡沫密度 PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E","methodology_zh":"泡沫密度"},{"_id":"6a5dc9b1f1c10c8ce825bb79","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Chłonność wody w podwyższonej temperaturze","methodology_en":"Water absorption at elevated temperature","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Chłonność wody w podwyższonej temperaturze\nMetoda wagowa","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Chłonność wody w podwyższonej temperaturze\nMetoda wagowa PN-EN 448 | EN 448 Ksztaltki preizolowaneE Chlonnosc wody w podwyzszonej temperaturze\nMetoda wagowa PN-EN 448 | EN 448","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Water absorption at elevated temperature Gravimetric method PN-EN 448 | EN 448","search_zh":"预制保温管件 E 高温下的吸水性 重量法 PN-EN 448 | EN 448","technique_zh":"重量法","test_object_zh":"预制保温管件 E","methodology_zh":"高温下的吸水性"},{"_id":"6a5dc9b1f1c10c8ce825bb7a","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Długość odcinków rury przewodowej bez izolacji na końcach kształtki","methodology_en":"Length of the pipe sections without insulation at the ends of the fitting","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość odcinków rury przewodowej bez izolacji na końcach kształtki","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Długość odcinków rury przewodowej bez izolacji na końcach kształtki PN-EN 448 | EN 448 Ksztaltki preizolowaneE Dlugosc odcinkow rury przewodowej bez izolacji na koncach ksztaltki PN-EN 448 | EN 448","categories":["construction"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Length of the pipe sections without insulation at the ends of the fitting PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb7b","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Odchylenie od osi na końcach kształtki","methodology_en":"Deviation from the axis at the ends of the fitting","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odchylenie od osi na końcach kształtki","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Odchylenie od osi na końcach kształtki PN-EN 448 | EN 448 Ksztaltki preizolowaneE Odchylenie od osi na koncach ksztaltki PN-EN 448 | EN 448","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Deviation from the axis at the ends of the fitting PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb7c","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Odchylenie kątowe rury przewodowej względem osłony na końcach kształtki","methodology_en":"Angular deviation of the service pipe relative to the casing at the ends of the fitting","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odchylenie kątowe rury przewodowej względem osłony na końcach kształtki","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Odchylenie kątowe rury przewodowej względem osłony na końcach kształtki PN-EN 448 | EN 448 Ksztaltki preizolowaneE Odchylenie katowe rury przewodowej wzgledem oslony na koncach ksztaltki PN-EN 448 | EN 448","categories":["other"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Angular deviation of the service pipe relative to the casing at the ends of the fitting PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb7d","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Kąt pomiędzy dwoma sąsiednimi segmentami osłony","methodology_en":"Angle between two adjacent segments of the guard","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kąt pomiędzy dwoma sąsiednimi segmentami osłony","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Kąt pomiędzy dwoma sąsiednimi segmentami osłony PN-EN 448 | EN 448 Ksztaltki preizolowaneE Kat pomiedzy dwoma sasiednimi segmentami oslony PN-EN 448 | EN 448","categories":["other"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Angle between two adjacent segments of the guard PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb7e","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Długość segmentów osłony na końcach kształtki","methodology_en":"Length of the casing segments at the ends of the fitting","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość segmentów osłony na końcach kształtki","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Długość segmentów osłony na końcach kształtki PN-EN 448 | EN 448 Ksztaltki preizolowaneE Dlugosc segmentow oslony na koncach ksztaltki PN-EN 448 | EN 448","categories":["other"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Length of the casing segments at the ends of the fitting PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb7f","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Wizualna ocena połączeń osłony","methodology_en":"Visual assessment of the joints of the enclosure","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wizualna ocena połączeń osłony","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Wizualna ocena połączeń osłony PN-EN 448 | EN 448 Ksztaltki preizolowaneE Wizualna ocena polaczen oslony PN-EN 448 | EN 448","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Visual assessment of the joints of the enclosure PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb80","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Zginanie połączeń osłony","methodology_en":"Bending of the casing connections","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zginanie połączeń osłony","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Zginanie połączeń osłony PN-EN 448 | EN 448 Ksztaltki preizolowaneE Zginanie polaczen oslony PN-EN 448 | EN 448","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Bending of the casing connections PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb81","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Wymiary osłony: Średnica zewnętrzna i grubość ścianki osłony","methodology_en":"Dimensions of the casing: Outside diameter and wall thickness of the casing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary osłony: Średnica zewnętrzna i grubość ścianki osłony","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Wymiary osłony: Średnica zewnętrzna i grubość ścianki osłony PN-EN 448 | EN 448 Ksztaltki preizolowaneE Wymiary oslony: Srednica zewnetrzna i grubosc scianki oslony PN-EN 448 | EN 448","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Dimensions of the casing: Outside diameter and wall thickness of the casing PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb82","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Minimalna grubość izolacji","methodology_en":"Minimum insulation thickness","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Minimalna grubość izolacji","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Minimalna grubość izolacji PN-EN 448 | EN 448 Ksztaltki preizolowaneE Minimalna grubosc izolacji PN-EN 448 | EN 448","categories":["construction"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Minimum insulation thickness PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb83","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Tolerancje głównych wymiarów kształtki","methodology_en":"Tolerances of the main dimensions of the fitting","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Tolerancje głównych wymiarów kształtki","reference":"PN-EN 448 | EN 448","norm_bases":["PN-EN 448","EN 448"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Tolerancje głównych wymiarów kształtki PN-EN 448 | EN 448 Ksztaltki preizolowaneE Tolerancje glownych wymiarow ksztaltki PN-EN 448 | EN 448","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Tolerances of the main dimensions of the fitting PN-EN 448 | EN 448","search_zh":"预制保温管件 E PN-EN 448 | EN 448","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb84","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kształtki preizolowaneE","test_object_en":"Pre-insulated fittingsE","methodology":"Szczelność osłony","methodology_en":"Guard tightness","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność osłony","reference":"IB-SB-19-2","norm_bases":["IB-SB-19-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kształtki preizolowaneE Szczelność osłony IB-SB-19-2 Ksztaltki preizolowaneE Szczelnosc oslony IB-SB-19-2","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pre-insulated fittingsE Guard tightness IB-SB-19-2","search_zh":"预制保温管件 E IB-SB-19-2","test_object_zh":"预制保温管件 E"},{"_id":"6a5dc9b1f1c10c8ce825bb85","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Grubość i średnica zewnętrzna ścianki rury przewodowej","methodology_en":"Wall thickness and outside diameter of the conduit pipe","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość i średnica zewnętrzna ścianki rury przewodowej","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Grubość i średnica zewnętrzna ścianki rury przewodowej PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Grubosc i srednica zewnetrzna scianki rury przewodowej PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Wall thickness and outside diameter of the conduit pipe PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb86","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Długość nieizolowanych końców rur przewodowych","methodology_en":"Length of uninsulated ends of conduit pipes","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość nieizolowanych końców rur przewodowych","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Długość nieizolowanych końców rur przewodowych PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Dlugosc nieizolowanych koncow rur przewodowych PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Length of uninsulated ends of conduit pipes PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb87","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Średnica zewnętrzna i grubość ścianki osłony","methodology_en":"Outside diameter and wall thickness of the sheath","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica zewnętrzna i grubość ścianki osłony","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Średnica zewnętrzna i grubość ścianki osłony PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Srednica zewnetrzna i grubosc scianki oslony PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Outside diameter and wall thickness of the sheath PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb88","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Wymiar komórki","methodology_en":"Cell size","parameters":[{"name":"Zakres","range":"do 2 mm"}],"parameters_en":[{"name":"Range","range":"do 2 mm"}],"technique":"Metoda stereoskopowa","techniques":["Metoda stereoskopowa"],"technique_en":"Stereoscopic method","computed":[],"computed_en":[],"activity":"Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Wymiar komorki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Cell size Stereoscopic method Range PN-EN 15698-1 | EN 15698-1","parameters_zh":[{"name":"范围","range":"do 2 mm"}],"search_zh":"用于建设热水管网的双管预制保温管道E 孔室尺寸 体视显微镜法 范围 PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E","methodology_zh":"孔室尺寸","technique_zh":"体视显微镜法"},{"_id":"6a5dc9b1f1c10c8ce825bb89","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Udział komórek zamkniętych, Pomiar zmiany ciśnienia","methodology_en":"Closed cell content, Pressure change measurement","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Udział komórek zamkniętych, Pomiar zmiany ciśnienia","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Udział komórek zamkniętych, Pomiar zmiany ciśnienia PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Udzial komorek zamknietych, Pomiar zmiany cisnienia PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Closed cell content, Pressure change measurement PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E 闭孔率，压力变化测量 PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E","methodology_zh":"闭孔率，压力变化测量"},{"_id":"6a5dc9b1f1c10c8ce825bb8a","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Puste przestrzenie i pęcherze, Pomiar wielkości geometrycznych","methodology_en":"Voids and blisters, Measurement of geometrical dimensions","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Puste przestrzenie i pęcherze, Pomiar wielkości geometrycznych","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Puste przestrzenie i pęcherze, Pomiar wielkości geometrycznych PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Puste przestrzenie i pecherze, Pomiar wielkosci geometrycznych PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Voids and blisters, Measurement of geometrical dimensions PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb8b","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres maszyny do 10 kN","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Wytrzymałość na ściskanie\nZakres maszyny do 10 kN PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Wytrzymalosc na sciskanie\nZakres maszyny do 10 kN PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Compressive strength Machine range PN-EN 15698-1 | EN 15698-1","methodology_zh":"抗压强度","search_zh":"用于建设热水管网的双管预制保温管道E 抗压强度 机器量程 PN-EN 15698-1 | EN 15698-1","parameters_zh":[{"name":"机器量程","range":"do 10 kN"}],"test_object_zh":"用于建设热水管网的双管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb8c","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Gęstość pianki","methodology_en":"Foam density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość pianki","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Gęstość pianki PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Gestosc pianki PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Foam density PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E 泡沫密度 PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E","methodology_zh":"泡沫密度"},{"_id":"6a5dc9b1f1c10c8ce825bb8d","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Chłonność wody w podwyższonej temperaturze","methodology_en":"Water absorption at elevated temperature","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Chłonność wody w podwyższonej temperaturze\nMetoda wagowa","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Chłonność wody w podwyższonej temperaturze\nMetoda wagowa PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Chlonnosc wody w podwyzszonej temperaturze\nMetoda wagowa PN-EN 15698-1 | EN 15698-1","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Water absorption at elevated temperature Gravimetric method PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E 高温下的吸水性 重量法 PN-EN 15698-1 | EN 15698-1","technique_zh":"重量法","test_object_zh":"用于建设热水管网的双管预制保温管道E","methodology_zh":"高温下的吸水性"},{"_id":"6a5dc9b1f1c10c8ce825bb8e","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Wyrównanie końców rur przewodowych","methodology_en":"Alignment of the ends of pipeline pipes","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wyrównanie końców rur przewodowych","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Wyrównanie końców rur przewodowych PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Wyrownanie koncow rur przewodowych PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Alignment of the ends of pipeline pipes PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb8f","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Odległość między rurami przewodowymi","methodology_en":"Distance between service pipes","parameters":[],"parameters_en":[],"technique":"Metoda pomiaru wielkości geometrycznych","techniques":["Metoda pomiaru wielkości geometrycznych"],"technique_en":"Method of measuring geometrical quantities","computed":[],"computed_en":[],"activity":"Odległość między rurami przewodowymi\nMetoda pomiaru wielkości geometrycznych","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Odległość między rurami przewodowymi\nMetoda pomiaru wielkości geometrycznych PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Odleglosc miedzy rurami przewodowymi\nMetoda pomiaru wielkosci geometrycznych PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Distance between service pipes Method of measuring geometrical quantities PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E 几何量测量法 PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E","technique_zh":"几何量测量法"},{"_id":"6a5dc9b1f1c10c8ce825bb90","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Skręcenie rur przewodowych","methodology_en":"Torsion of line pipes","parameters":[],"parameters_en":[],"technique":"Metoda pomiaru wielkości geometrycznych","techniques":["Metoda pomiaru wielkości geometrycznych"],"technique_en":"Method of measuring geometrical quantities","computed":[],"computed_en":[],"activity":"Skręcenie rur przewodowych\nMetoda pomiaru wielkości geometrycznych","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Skręcenie rur przewodowych\nMetoda pomiaru wielkości geometrycznych PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Skrecenie rur przewodowych\nMetoda pomiaru wielkosci geometrycznych PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Torsion of line pipes Method of measuring geometrical quantities PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E 几何量测量法 PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E","technique_zh":"几何量测量法"},{"_id":"6a5dc9b1f1c10c8ce825bb91","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Odchylenie od osi","methodology_en":"Deviation from the axis","parameters":[],"parameters_en":[],"technique":"Metoda pomiaru wielkości geometrycznych","techniques":["Metoda pomiaru wielkości geometrycznych"],"technique_en":"Method of measuring geometrical quantities","computed":[],"computed_en":[],"activity":"Odchylenie od osi\nMetoda pomiaru wielkości geometrycznych","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Odchylenie od osi\nMetoda pomiaru wielkości geometrycznych PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Odchylenie od osi\nMetoda pomiaru wielkosci geometrycznych PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Deviation from the axis Method of measuring geometrical quantities PN-EN 15698-1 | EN 15698-1","search_zh":"用于建设热水管网的双管预制保温管道E 几何量测量法 PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E","technique_zh":"几何量测量法"},{"_id":"6a5dc9b1f1c10c8ce825bb92","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE","test_object_en":"Double pre-insulated pipes for the construction of water district heating networksE","methodology":"Wytrzymałość na ścinanie w kierunku osiowym","methodology_en":"Shear strength in the axial direction","parameters":[{"name":"Zakres maszyny","range":"do 40 kN"}],"parameters_en":[{"name":"Machine range","range":"do 40 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie w kierunku osiowym\nZakres maszyny do 40 kN","reference":"PN-EN 15698-1 | EN 15698-1","norm_bases":["PN-EN 15698-1","EN 15698-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane podwójne do budowy wodnych sieci ciepłowniczychE Wytrzymałość na ścinanie w kierunku osiowym\nZakres maszyny do 40 kN PN-EN 15698-1 | EN 15698-1 Rury preizolowane podwojne do budowy wodnych sieci cieplowniczychE Wytrzymalosc na scinanie w kierunku osiowym\nZakres maszyny do 40 kN PN-EN 15698-1 | EN 15698-1","categories":["other"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Double pre-insulated pipes for the construction of water district heating networksE Shear strength in the axial direction Machine range PN-EN 15698-1 | EN 15698-1","parameters_zh":[{"name":"机器量程","range":"do 40 kN"}],"search_zh":"用于建设热水管网的双管预制保温管道E 机器量程 PN-EN 15698-1 | EN 15698-1","test_object_zh":"用于建设热水管网的双管预制保温管道E"},{"_id":"6a5dc9b1f1c10c8ce825bb93","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Przewodność cieplna, Zakres do 0,080 W/mK","methodology_en":"Thermal conductivity, Range up to 0,080 W/mK","parameters":[],"parameters_en":[],"technique":"Metoda: aparat rurowy","techniques":["Metoda: aparat rurowy"],"technique_en":"Method: tube apparatus","computed":[],"computed_en":[],"activity":"Przewodność cieplna, Zakres do 0,080 W/mK\nMetoda: aparat rurowy","reference":"PN-EN ISO 8497","norm_bases":["PN-EN ISO 8497"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Przewodność cieplna, Zakres do 0,080 W/mK\nMetoda: aparat rurowy PN-EN ISO 8497 Wyroby wlokniste, Tworzywa sztuczne porowate E Przewodnosc cieplna, Zakres do 0,080 W/mK\nMetoda: aparat rurowy PN-EN ISO 8497","categories":["materials"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Thermal conductivity, Range up to 0,080 W/mK Method: tube apparatus PN-EN ISO 8497","search_zh":"纤维制品、多孔塑料 E PN-EN ISO 8497","test_object_zh":"纤维制品、多孔塑料 E"},{"_id":"6a5dc9b1f1c10c8ce825bb94","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Przewodność cieplna","methodology_en":"Thermal conductivity","parameters":[{"name":"Zakres","range":"do 0,080 W/mK"}],"parameters_en":[{"name":"Range","range":"do 0,080 W/mK"}],"technique":"Metoda: aparat płytowy","techniques":["Metoda: aparat płytowy"],"technique_en":"Method: plate apparatus","computed":[],"computed_en":[],"activity":"Przewodność cieplna\nZakres do 0,080 W/mK\nMetoda: aparat płytowy","reference":"PN-ISO 8301","norm_bases":["PN-ISO 8301"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Przewodność cieplna\nZakres do 0,080 W/mK\nMetoda: aparat płytowy PN-ISO 8301 Wyroby wlokniste, Tworzywa sztuczne porowate E Przewodnosc cieplna\nZakres do 0,080 W/mK\nMetoda: aparat plytowy PN-ISO 8301","categories":["materials"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Thermal conductivity Method: plate apparatus Range PN-ISO 8301","parameters_zh":[{"name":"范围","range":"do 0,080 W/mK"}],"search_zh":"纤维制品、多孔塑料 E 范围 PN-ISO 8301","test_object_zh":"纤维制品、多孔塑料 E"},{"_id":"6a5dc9b1f1c10c8ce825bb95","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Gęstość","methodology_en":"Density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość","reference":"PN-EN ISO 845 | PN-EN 1602 | PN-EN ISO 18098","norm_bases":["PN-EN ISO 845","PN-EN 1602","PN-EN ISO 18098"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Gęstość PN-EN ISO 845 | PN-EN 1602 | PN-EN ISO 18098 Wyroby wlokniste, Tworzywa sztuczne porowate E Gestosc PN-EN ISO 845 | PN-EN 1602 | PN-EN ISO 18098","categories":["materials"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Density PN-EN ISO 845 | PN-EN 1602 | PN-EN ISO 18098","methodology_zh":"密度","search_zh":"纤维制品、多孔塑料 E 密度 PN-EN ISO 845 | PN-EN 1602 | PN-EN ISO 18098","test_object_zh":"纤维制品、多孔塑料 E"},{"_id":"6a5dc9b1f1c10c8ce825bb96","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres maszyny do 10 kN","reference":"PN-EN ISO 29469 | PN-EN ISO 844 Metoda A","norm_bases":["PN-EN ISO 29469","PN-EN ISO 844 Metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Wytrzymałość na ściskanie\nZakres maszyny do 10 kN PN-EN ISO 29469 | PN-EN ISO 844 Metoda A Wyroby wlokniste, Tworzywa sztuczne porowate E Wytrzymalosc na sciskanie\nZakres maszyny do 10 kN PN-EN ISO 29469 | PN-EN ISO 844 Metoda A","categories":["materials"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Compressive strength Machine range PN-EN ISO 29469 | PN-EN ISO 844 Metoda A","methodology_zh":"抗压强度","search_zh":"纤维制品、多孔塑料 E 抗压强度 机器量程 PN-EN ISO 29469 | PN-EN ISO 844 Metoda A","parameters_zh":[{"name":"机器量程","range":"do 10 kN"}],"test_object_zh":"纤维制品、多孔塑料 E"},{"_id":"6a5dc9b1f1c10c8ce825bb97","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Udział komórek zamkniętych/otwartych, Pomiar zmiany ciśnienia","methodology_en":"Content of closed/open cells, Pressure change measurement","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Udział komórek zamkniętych/otwartych, Pomiar zmiany ciśnienia","reference":"PN-EN ISO 4590 Metoda 1","norm_bases":["PN-EN ISO 4590 Metoda 1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Udział komórek zamkniętych/otwartych, Pomiar zmiany ciśnienia PN-EN ISO 4590 Metoda 1 Wyroby wlokniste, Tworzywa sztuczne porowate E Udzial komorek zamknietych/otwartych, Pomiar zmiany cisnienia PN-EN ISO 4590 Metoda 1","categories":["materials"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Content of closed/open cells, Pressure change measurement PN-EN ISO 4590 Metoda 1","search_zh":"纤维制品、多孔塑料 E PN-EN ISO 4590 Metoda 1","test_object_zh":"纤维制品、多孔塑料 E"},{"_id":"6a5dc9b1f1c10c8ce825bb98","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Wymiar komórki","methodology_en":"Cell size","parameters":[{"name":"Zakres","range":"do 2 mm"}],"parameters_en":[{"name":"Range","range":"do 2 mm"}],"technique":"Metoda stereoskopowa","techniques":["Metoda stereoskopowa"],"technique_en":"Stereoscopic method","computed":[],"computed_en":[],"activity":"Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Wymiar komórki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 253 | EN 253 Wyroby wlokniste, Tworzywa sztuczne porowate E Wymiar komorki\nZakres do 2 mm\nMetoda stereoskopowa PN-EN 253 | EN 253","categories":["materials"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Cell size Stereoscopic method Range PN-EN 253 | EN 253","parameters_zh":[{"name":"范围","range":"do 2 mm"}],"search_zh":"纤维制品、多孔塑料 E 孔室尺寸 体视显微镜法 范围 PN-EN 253 | EN 253","test_object_zh":"纤维制品、多孔塑料 E","methodology_zh":"孔室尺寸","technique_zh":"体视显微镜法"},{"_id":"6a5dc9b1f1c10c8ce825bb99","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Chłonność wody w podwyższonej temperaturze","methodology_en":"Water absorption at elevated temperature","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Chłonność wody w podwyższonej temperaturze\nMetoda wagowa","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Chłonność wody w podwyższonej temperaturze\nMetoda wagowa PN-EN 253 | EN 253 Wyroby wlokniste, Tworzywa sztuczne porowate E Chlonnosc wody w podwyzszonej temperaturze\nMetoda wagowa PN-EN 253 | EN 253","categories":["water","materials"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Water absorption at elevated temperature Gravimetric method PN-EN 253 | EN 253","search_zh":"纤维制品、多孔塑料 E 高温下的吸水性 重量法 PN-EN 253 | EN 253","technique_zh":"重量法","test_object_zh":"纤维制品、多孔塑料 E","methodology_zh":"高温下的吸水性"},{"_id":"6a5dc9b1f1c10c8ce825bb9a","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Odporność termiczna","methodology_en":"Thermal resistance","parameters":[{"name":"Zakres komory grzejnej","range":"do 250 °C"},{"name":"Zakres maszyny wytrzymałościowej:","range":"do 10 kN"}],"parameters_en":[{"name":"Range of the heating chamber","range":"do 250 °C"},{"name":"Range of the testing machine:","range":"do 10 kN"}],"technique":"Metoda pomiaru wielkości geometrycznych","techniques":["Metoda pomiaru wielkości geometrycznych"],"technique_en":"Method of measuring geometrical quantities","computed":[],"computed_en":[],"activity":"Odporność termiczna\nZakres:\nZakres komory grzejnej do 250 °C\nZakres maszyny wytrzymałościowej: do 10 kN\nMetoda pomiaru wielkości geometrycznych","reference":"PB-01","norm_bases":["PB-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Odporność termiczna\nZakres:\nZakres komory grzejnej do 250 °C\nZakres maszyny wytrzymałościowej: do 10 kN\nMetoda pomiaru wielkości geometrycznych PB-01 Wyroby wlokniste, Tworzywa sztuczne porowate E Odpornosc termiczna\nZakres:\nZakres komory grzejnej do 250 °C\nZakres maszyny wytrzymalosciowej: do 10 kN\nMetoda pomiaru wielkosci geometrycznych PB-01","categories":["materials"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Thermal resistance Method of measuring geometrical quantities Range of the heating chamber Range of the testing machine: PB-01","methodology_zh":"耐热性","search_zh":"纤维制品、多孔塑料 E 耐热性 几何量测量法 PB-01","test_object_zh":"纤维制品、多孔塑料 E","technique_zh":"几何量测量法"},{"_id":"6a5dc9b1f1c10c8ce825bb9b","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Puste przestrzenie i pęcherze","methodology_en":"Voids and blisters","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Puste przestrzenie i pęcherze","reference":"PN-EN 253 | EN 253","norm_bases":["PN-EN 253","EN 253"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Puste przestrzenie i pęcherze PN-EN 253 | EN 253 Wyroby wlokniste, Tworzywa sztuczne porowate E Puste przestrzenie i pecherze PN-EN 253 | EN 253","categories":["materials"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Voids and blisters PN-EN 253 | EN 253","search_zh":"纤维制品、多孔塑料 E PN-EN 253 | EN 253","test_object_zh":"纤维制品、多孔塑料 E"},{"_id":"6a5dc9b1f1c10c8ce825bb9c","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Charakterystyka naprężenieodkształcenie przy ściskaniu","methodology_en":"Stress-strain characteristic in compression","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Charakterystyka naprężenieodkształcenie przy ściskaniu","reference":"PN-EN ISO 3386-1 | PN-EN 13941-1","norm_bases":["PN-EN ISO 3386-1","PN-EN 13941-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Charakterystyka naprężenieodkształcenie przy ściskaniu PN-EN ISO 3386-1 | PN-EN 13941-1 Wyroby wlokniste, Tworzywa sztuczne porowate E Charakterystyka naprezenieodksztalcenie przy sciskaniu PN-EN ISO 3386-1 | PN-EN 13941-1","categories":["materials"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Stress-strain characteristic in compression PN-EN ISO 3386-1 | PN-EN 13941-1","search_zh":"纤维制品、多孔塑料 E PN-EN ISO 3386-1 | PN-EN 13941-1","test_object_zh":"纤维制品、多孔塑料 E"},{"_id":"6a5dc9b1f1c10c8ce825bb9d","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Odkształcenie trwałe po ściskaniu, Odkształcenie po ściskaniu","methodology_en":"Compression set, Deformation after compression","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odkształcenie trwałe po ściskaniu, Odkształcenie po ściskaniu","reference":"PN-EN ISO 1856 | ISO 1856 | PN-EN 13941-1","norm_bases":["PN-EN ISO 1856","ISO 1856","PN-EN 13941-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Odkształcenie trwałe po ściskaniu, Odkształcenie po ściskaniu PN-EN ISO 1856 | ISO 1856 | PN-EN 13941-1 Wyroby wlokniste, Tworzywa sztuczne porowate E Odksztalcenie trwale po sciskaniu, Odksztalcenie po sciskaniu PN-EN ISO 1856 | ISO 1856 | PN-EN 13941-1","categories":["materials"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Compression set, Deformation after compression PN-EN ISO 1856 | ISO 1856 | PN-EN 13941-1","search_zh":"纤维制品、多孔塑料 E PN-EN ISO 1856 | ISO 1856 | PN-EN 13941-1","test_object_zh":"纤维制品、多孔塑料 E"},{"_id":"6a5dc9b1f1c10c8ce825bb9e","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Wymiary liniowe","methodology_en":"Linear dimensions","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe","reference":"PN-EN ISO 1923","norm_bases":["PN-EN ISO 1923"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Wymiary liniowe PN-EN ISO 1923 Wyroby wlokniste, Tworzywa sztuczne porowate E Wymiary liniowe PN-EN ISO 1923","categories":["materials"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Linear dimensions PN-EN ISO 1923","methodology_zh":"线性尺寸","search_zh":"纤维制品、多孔塑料 E 线性尺寸 PN-EN ISO 1923","test_object_zh":"纤维制品、多孔塑料 E"},{"_id":"6a5dc9b1f1c10c8ce825bb9f","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate E","test_object_en":"Fibrous products, Cellular plastics E","methodology":"Chłonność wody metodą wyporu hydrostatycznego","methodology_en":"Water absorption by the hydrostatic buoyancy method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Chłonność wody metodą wyporu hydrostatycznego","reference":"PN-93/C-89084 | ISO 2896","norm_bases":["PN-93/C-89084","ISO 2896"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate E Chłonność wody metodą wyporu hydrostatycznego PN-93/C-89084 | ISO 2896 Wyroby wlokniste, Tworzywa sztuczne porowate E Chlonnosc wody metoda wyporu hydrostatycznego PN-93/C-89084 | ISO 2896","categories":["water","materials"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics E Water absorption by the hydrostatic buoyancy method PN-93/C-89084 | ISO 2896","search_zh":"纤维制品、多孔塑料 E PN-93/C-89084 | ISO 2896","test_object_zh":"纤维制品、多孔塑料 E"},{"_id":"6a5dc9b1f1c10c8ce825bba0","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Tworzywa sztuczne termoplastyczneE","test_object_en":"Thermoplastic plasticsE","methodology":"Próba zginania","methodology_en":"Bend test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba zginania","reference":"PN-EN 12814-1","norm_bases":["PN-EN 12814-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne termoplastyczneE Próba zginania PN-EN 12814-1 Tworzywa sztuczne termoplastyczneE Proba zginania PN-EN 12814-1","categories":["materials"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Thermoplastic plasticsE Bend test PN-EN 12814-1","methodology_zh":"弯曲试验","search_zh":"热塑性塑料E 弯曲试验 PN-EN 12814-1","test_object_zh":"热塑性塑料E"},{"_id":"6a5dc9b1f1c10c8ce825bba1","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Tworzywa sztuczne termoplastyczneE","test_object_en":"Thermoplastic plasticsE","methodology":"Odporność na pękanie naprężeniowe (SCR)","methodology_en":"Stress cracking resistance (SCR)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pękanie naprężeniowe (SCR)","reference":"ISO 16770","norm_bases":["ISO 16770"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne termoplastyczneE Odporność na pękanie naprężeniowe (SCR) ISO 16770 Tworzywa sztuczne termoplastyczneE Odpornosc na pekanie naprezeniowe (SCR) ISO 16770","categories":["materials"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Thermoplastic plasticsE Stress cracking resistance (SCR) ISO 16770","methodology_zh":"耐应力开裂性（SCR）","search_zh":"热塑性塑料E 耐应力开裂性（SCR） ISO 16770","test_object_zh":"热塑性塑料E"},{"_id":"6a5dc9b1f1c10c8ce825bba2","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Tworzywa sztuczne termoplastyczneE","test_object_en":"Thermoplastic plasticsE","methodology":"Wydłużenie przy zerwaniu","methodology_en":"Elongation at break","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie przy zerwaniu","reference":"PN-EN ISO 527-1","norm_bases":["PN-EN ISO 527-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne termoplastyczneE Wydłużenie przy zerwaniu PN-EN ISO 527-1 Tworzywa sztuczne termoplastyczneE Wydluzenie przy zerwaniu PN-EN ISO 527-1","categories":["materials"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Thermoplastic plasticsE Elongation at break PN-EN ISO 527-1","methodology_zh":"断裂伸长率","search_zh":"热塑性塑料E 断裂伸长率 PN-EN ISO 527-1","test_object_zh":"热塑性塑料E"},{"_id":"6a5dc9b1f1c10c8ce825bba3","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Tworzywa sztuczne termoplastyczneE","test_object_en":"Thermoplastic plasticsE","methodology":"Wytrzymałość na rozciąganie","methodology_en":"Tensile strength","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie\nZakres maszyny do 10 kN","reference":"PN-EN ISO 527-1","norm_bases":["PN-EN ISO 527-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne termoplastyczneE Wytrzymałość na rozciąganie\nZakres maszyny do 10 kN PN-EN ISO 527-1 Tworzywa sztuczne termoplastyczneE Wytrzymalosc na rozciaganie\nZakres maszyny do 10 kN PN-EN ISO 527-1","categories":["materials"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Thermoplastic plasticsE Tensile strength Machine range PN-EN ISO 527-1","methodology_zh":"抗拉强度","parameters_zh":[{"name":"机器量程","range":"do 10 kN"}],"search_zh":"热塑性塑料E 抗拉强度 机器量程 PN-EN ISO 527-1","test_object_zh":"热塑性塑料E"},{"_id":"6a5dc9b1f1c10c8ce825bba4","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Tworzywa sztuczne termoplastyczneE","test_object_en":"Thermoplastic plasticsE","methodology":"Próba rozciągania","methodology_en":"Tensile test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba rozciągania","reference":"PN-EN ISO 527-1","norm_bases":["PN-EN ISO 527-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne termoplastyczneE Próba rozciągania PN-EN ISO 527-1 Tworzywa sztuczne termoplastyczneE Proba rozciagania PN-EN ISO 527-1","categories":["materials"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Thermoplastic plasticsE Tensile test PN-EN ISO 527-1","methodology_zh":"拉伸试验","search_zh":"热塑性塑料E 拉伸试验 PN-EN ISO 527-1","test_object_zh":"热塑性塑料E"},{"_id":"6a5dc9b1f1c10c8ce825bba5","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Kaptur końcowy termokurczliwyE","test_object_en":"Heat-shrinkable end capE","methodology":"Szczelność","methodology_en":"Leak tightness","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność","reference":"IB-SB-19-1 | IB-SB-19-2","norm_bases":["IB-SB-19-1","IB-SB-19-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kaptur końcowy termokurczliwyE Szczelność IB-SB-19-1 | IB-SB-19-2 Kaptur koncowy termokurczliwyE Szczelnosc IB-SB-19-1 | IB-SB-19-2","categories":["other"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Heat-shrinkable end capE Leak tightness IB-SB-19-1 | IB-SB-19-2","methodology_zh":"密封性","search_zh":"密封性 IB-SB-19-1 | IB-SB-19-2"},{"_id":"6a5dc9b1f1c10c8ce825bba6","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Tworzywa sztuczne termoplastyczne","test_object_en":"Thermoplastic plastics","methodology":"Stopień sieciowania","methodology_en":"Degree of crosslinking","parameters":[],"parameters_en":[],"technique":"Metoda oznaczania zawartości żelu","techniques":["Metoda oznaczania zawartości żelu"],"technique_en":"Method for determining gel content","computed":[],"computed_en":[],"activity":"Stopień sieciowania\nMetoda oznaczania zawartości żelu","reference":"PN-EN ISO 10147:2013-06 | PN-EN 579:2001","norm_bases":["PN-EN ISO 10147:2013-06","PN-EN 579:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne termoplastyczne Stopień sieciowania\nMetoda oznaczania zawartości żelu PN-EN ISO 10147:2013-06 | PN-EN 579:2001 Tworzywa sztuczne termoplastyczne Stopien sieciowania\nMetoda oznaczania zawartosci zelu PN-EN ISO 10147:2013-06 | PN-EN 579:2001","categories":["materials"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Thermoplastic plastics Degree of crosslinking Method for determining gel content PN-EN ISO 10147:2013-06 | PN-EN 579:2001"},{"_id":"6a5dc9b1f1c10c8ce825bba7","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Tworzywa sztuczne termoplastyczne","test_object_en":"Thermoplastic plastics","methodology":"Wydłużenie przy zerwaniu Wytrzymałość na rozciąganie Granica plastyczności","methodology_en":"Elongation at break Tensile strength Yield strength","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"},{"name":"Próba rozciągania"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"},{"name":"Tensile test"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie przy zerwaniu Wytrzymałość na rozciąganie Granica plastyczności\nZakres:\nZakres maszyny do 10 kN\nPróba rozciągania","reference":"PN-EN ISO 6259-1:2015-05 | PN-EN ISO 6259-3:2015-08","norm_bases":["PN-EN ISO 6259-1:2015-05","PN-EN ISO 6259-3:2015-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne termoplastyczne Wydłużenie przy zerwaniu Wytrzymałość na rozciąganie Granica plastyczności\nZakres:\nZakres maszyny do 10 kN\nPróba rozciągania PN-EN ISO 6259-1:2015-05 | PN-EN ISO 6259-3:2015-08 Tworzywa sztuczne termoplastyczne Wydluzenie przy zerwaniu Wytrzymalosc na rozciaganie Granica plastycznosci\nZakres:\nZakres maszyny do 10 kN\nProba rozciagania PN-EN ISO 6259-1:2015-05 | PN-EN ISO 6259-3:2015-08","categories":["materials"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Thermoplastic plastics Elongation at break Tensile strength Yield strength Machine range Tensile test PN-EN ISO 6259-1:2015-05 | PN-EN ISO 6259-3:2015-08","parameters_zh":[{"name":"机器量程","range":"do 10 kN"},{"name":"拉伸试验"}],"search_zh":"机器量程 拉伸试验 PN-EN ISO 6259-1:2015-05 | PN-EN ISO 6259-3:2015-08"},{"_id":"6a5dc9b1f1c10c8ce825bba8","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Wymiary geometryczne otuliny","methodology_en":"Geometric dimensions of the insulation shell","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne otuliny","reference":"PN-EN ISO 12628:2023-02","norm_bases":["PN-EN ISO 12628:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Wymiary geometryczne otuliny PN-EN ISO 12628:2023-02 Wyroby wlokniste, Tworzywa sztuczne porowate Wymiary geometryczne otuliny PN-EN ISO 12628:2023-02","categories":["materials"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Geometric dimensions of the insulation shell PN-EN ISO 12628:2023-02","search_zh":"纤维制品、多孔塑料 PN-EN ISO 12628:2023-02","test_object_zh":"纤维制品、多孔塑料"},{"_id":"6a5dc9b1f1c10c8ce825bba9","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Wymiary i tolerancje","methodology_en":"Dimensions and tolerances","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary i tolerancje","reference":"PN-EN ISO 12628:2023-02","norm_bases":["PN-EN ISO 12628:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Wymiary i tolerancje PN-EN ISO 12628:2023-02 Wyroby wlokniste, Tworzywa sztuczne porowate Wymiary i tolerancje PN-EN ISO 12628:2023-02","categories":["materials"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Dimensions and tolerances PN-EN ISO 12628:2023-02","search_zh":"纤维制品、多孔塑料 尺寸与公差 PN-EN ISO 12628:2023-02","test_object_zh":"纤维制品、多孔塑料","methodology_zh":"尺寸与公差"},{"_id":"6a5dc9b1f1c10c8ce825bbaa","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Liniowość","methodology_en":"Linearity","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Liniowość","reference":"PN-EN ISO 12628:2023-02","norm_bases":["PN-EN ISO 12628:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Liniowość PN-EN ISO 12628:2023-02 Wyroby wlokniste, Tworzywa sztuczne porowate Liniowosc PN-EN ISO 12628:2023-02","categories":["materials"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Linearity PN-EN ISO 12628:2023-02","search_zh":"纤维制品、多孔塑料 PN-EN ISO 12628:2023-02","test_object_zh":"纤维制品、多孔塑料"},{"_id":"6a5dc9b1f1c10c8ce825bbab","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Prostokątność","methodology_en":"Squareness","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Prostokątność","reference":"PN-EN ISO 12628:2023-02","norm_bases":["PN-EN ISO 12628:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Prostokątność PN-EN ISO 12628:2023-02 Wyroby wlokniste, Tworzywa sztuczne porowate Prostokatnosc PN-EN ISO 12628:2023-02","categories":["materials"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Squareness PN-EN ISO 12628:2023-02","search_zh":"纤维制品、多孔塑料 直角度 PN-EN ISO 12628:2023-02","test_object_zh":"纤维制品、多孔塑料","methodology_zh":"直角度"},{"_id":"6a5dc9b1f1c10c8ce825bbac","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Maksymalna temperatura stosowania otulin","methodology_en":"Maximum service temperature of pipe insulation","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Maksymalna temperatura stosowania otulin","reference":"PN-EN ISO 18096:2023-02","norm_bases":["PN-EN ISO 18096:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Maksymalna temperatura stosowania otulin PN-EN ISO 18096:2023-02 Wyroby wlokniste, Tworzywa sztuczne porowate Maksymalna temperatura stosowania otulin PN-EN ISO 18096:2023-02","categories":["materials"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Maximum service temperature of pipe insulation PN-EN ISO 18096:2023-02","search_zh":"纤维制品、多孔塑料 PN-EN ISO 18096:2023-02","test_object_zh":"纤维制品、多孔塑料"},{"_id":"6a5dc9b1f1c10c8ce825bbad","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie","reference":"PN-EN ISO 29469:2023-05","norm_bases":["PN-EN ISO 29469:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Wytrzymałość na ściskanie PN-EN ISO 29469:2023-05 Wyroby wlokniste, Tworzywa sztuczne porowate Wytrzymalosc na sciskanie PN-EN ISO 29469:2023-05","categories":["materials"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Compressive strength PN-EN ISO 29469:2023-05","methodology_zh":"抗压强度","search_zh":"纤维制品、多孔塑料 抗压强度 PN-EN ISO 29469:2023-05","test_object_zh":"纤维制品、多孔塑料"},{"_id":"6a5dc9b1f1c10c8ce825bbae","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Naprężenie ściskające","methodology_en":"Compressive stress","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Naprężenie ściskające\nZakres maszyny do 10 kN","reference":"PN-EN ISO 29469:2023-05","norm_bases":["PN-EN ISO 29469:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Naprężenie ściskające\nZakres maszyny do 10 kN PN-EN ISO 29469:2023-05 Wyroby wlokniste, Tworzywa sztuczne porowate Naprezenie sciskajace\nZakres maszyny do 10 kN PN-EN ISO 29469:2023-05","categories":["materials"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Compressive stress Machine range PN-EN ISO 29469:2023-05","parameters_zh":[{"name":"机器量程","range":"do 10 kN"}],"search_zh":"纤维制品、多孔塑料 机器量程 PN-EN ISO 29469:2023-05","test_object_zh":"纤维制品、多孔塑料"},{"_id":"6a5dc9b1f1c10c8ce825bbaf","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Opór cieplny","methodology_en":"Thermal resistance","parameters":[{"name":"Zakres","range":"do 0,080 W/mK"}],"parameters_en":[{"name":"Range","range":"do 0,080 W/mK"}],"technique":"Metoda: aparat płytowy","techniques":["Metoda: aparat płytowy"],"technique_en":"Method: plate apparatus","computed":[],"computed_en":[],"activity":"Opór cieplny\nZakres do 0,080 W/mK\nMetoda: aparat płytowy","reference":"PN-EN ISO 12667:2002","norm_bases":["PN-EN ISO 12667:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Opór cieplny\nZakres do 0,080 W/mK\nMetoda: aparat płytowy PN-EN ISO 12667:2002 Wyroby wlokniste, Tworzywa sztuczne porowate Opor cieplny\nZakres do 0,080 W/mK\nMetoda: aparat plytowy PN-EN ISO 12667:2002","categories":["materials"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Thermal resistance Method: plate apparatus Range PN-EN ISO 12667:2002","parameters_zh":[{"name":"范围","range":"do 0,080 W/mK"}],"search_zh":"纤维制品、多孔塑料 热阻 范围 PN-EN ISO 12667:2002","test_object_zh":"纤维制品、多孔塑料","methodology_zh":"热阻"},{"_id":"6a5dc9b1f1c10c8ce825bbb0","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Wydłużenie przy zerwaniu","methodology_en":"Elongation at break","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydłużenie przy zerwaniu","reference":"PN-EN ISO 1798:2009","norm_bases":["PN-EN ISO 1798:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Wydłużenie przy zerwaniu PN-EN ISO 1798:2009 Wyroby wlokniste, Tworzywa sztuczne porowate Wydluzenie przy zerwaniu PN-EN ISO 1798:2009","categories":["materials"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Elongation at break PN-EN ISO 1798:2009","search_zh":"纤维制品、多孔塑料 断裂伸长率 PN-EN ISO 1798:2009","test_object_zh":"纤维制品、多孔塑料","methodology_zh":"断裂伸长率"},{"_id":"6a5dc9b1f1c10c8ce825bbb1","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Wytrzymałość na rozciąganie","methodology_en":"Tensile strength","parameters":[{"name":"Zakres maszyny","range":"do 10 kN"}],"parameters_en":[{"name":"Machine range","range":"do 10 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie\nZakres maszyny do 10 kN","reference":"PN-EN ISO 1798:2009","norm_bases":["PN-EN ISO 1798:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Wytrzymałość na rozciąganie\nZakres maszyny do 10 kN PN-EN ISO 1798:2009 Wyroby wlokniste, Tworzywa sztuczne porowate Wytrzymalosc na rozciaganie\nZakres maszyny do 10 kN PN-EN ISO 1798:2009","categories":["materials"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Tensile strength Machine range PN-EN ISO 1798:2009","methodology_zh":"抗拉强度","parameters_zh":[{"name":"机器量程","range":"do 10 kN"}],"search_zh":"纤维制品、多孔塑料 抗拉强度 机器量程 PN-EN ISO 1798:2009","test_object_zh":"纤维制品、多孔塑料"},{"_id":"6a5dc9b1f1c10c8ce825bbb2","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Wyroby włókniste, Tworzywa sztuczne porowate","test_object_en":"Fibrous products, Cellular plastics","methodology":"Próba rozciągania","methodology_en":"Tensile test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba rozciągania","reference":"PN-EN ISO 1798:2009","norm_bases":["PN-EN ISO 1798:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby włókniste, Tworzywa sztuczne porowate Próba rozciągania PN-EN ISO 1798:2009 Wyroby wlokniste, Tworzywa sztuczne porowate Proba rozciagania PN-EN ISO 1798:2009","categories":["materials"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fibrous products, Cellular plastics Tensile test PN-EN ISO 1798:2009","methodology_zh":"拉伸试验","search_zh":"纤维制品、多孔塑料 拉伸试验 PN-EN ISO 1798:2009","test_object_zh":"纤维制品、多孔塑料"},{"_id":"6a5dc9b1f1c10c8ce825bbb3","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"Rury preizolowane pojedyncze","test_object_en":"Single pre-insulated pipes","methodology":"Wytrzymałość na ścinanie w kierunku stycznym","methodology_en":"Shear strength in the tangential direction","parameters":[{"name":"Zakres maszyny","range":"do 40 kN"},{"name":"Wytrzymałość na ścinanie w kierunku"}],"parameters_en":[{"name":"Machine range","range":"do 40 kN"},{"name":"Shear strength in the direction"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie w kierunku stycznym\nZakres:\nZakres maszyny do 40 kN\nWytrzymałość na ścinanie w kierunku","reference":"PN-EN 253+A2:2015-12","norm_bases":["PN-EN 253+A2:2015-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury preizolowane pojedyncze Wytrzymałość na ścinanie w kierunku stycznym\nZakres:\nZakres maszyny do 40 kN\nWytrzymałość na ścinanie w kierunku PN-EN 253+A2:2015-12 Rury preizolowane pojedyncze Wytrzymalosc na scinanie w kierunku stycznym\nZakres:\nZakres maszyny do 40 kN\nWytrzymalosc na scinanie w kierunku PN-EN 253+A2:2015-12","categories":["other"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Single pre-insulated pipes Shear strength in the tangential direction Machine range Shear strength in the direction PN-EN 253+A2:2015-12","parameters_zh":[{"name":"机器量程","range":"do 40 kN"},{"name":"Wytrzymałość na ścinanie w kierunku"}],"search_zh":"机器量程 PN-EN 253+A2:2015-12"},{"_id":"6a5dc9b1f1c10c8ce825bbb4","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"do budowy wodnych sieci","test_object_en":"for the construction of water networks","methodology":"stycznym","methodology_en":"stycznym","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"stycznym","reference":"PN-EN 253+A2:2015-12","norm_bases":["PN-EN 253+A2:2015-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"do budowy wodnych sieci stycznym PN-EN 253+A2:2015-12 do budowy wodnych sieci stycznym PN-EN 253+A2:2015-12","categories":["other"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"for the construction of water networks stycznym PN-EN 253+A2:2015-12"},{"_id":"6a5dc9b1f1c10c8ce825bbb5","lab_id":"69ad52a3de79e566650fb211","country":"PL","accr_number":"AB 414","accr_body":"PCA","test_object":"ciepłowniczych","test_object_en":"district heating","methodology":"","methodology_en":null,"parameters":[{"name":"Zakres maszyny","range":"do 40 kN"}],"parameters_en":[{"name":"Machine range","range":"do 40 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"\nZakres maszyny do 40 kN","reference":"PN-EN 253+A2:2015-12","norm_bases":["PN-EN 253+A2:2015-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"ciepłowniczych \nZakres maszyny do 40 kN PN-EN 253+A2:2015-12 cieplowniczych \nZakres maszyny do 40 kN PN-EN 253+A2:2015-12","categories":["other"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"district heating Machine range PN-EN 253+A2:2015-12","parameters_zh":[{"name":"机器量程","range":"do 40 kN"}],"search_zh":"机器量程 PN-EN 253+A2:2015-12"}],"has_pdf":true}