🇵🇱 CENTRALNA STACJA RATOWNICTWA GÓRNICZEGO S.A. PL
环境
CENTRALNA STACJA RATOWNICTWA GÓRNICZEGO S.A. 是由 PCA 认可的实验室,认可编号 AB 321(Bytom,波兰)。认可范围涵盖 22 项检测方法,涉及以下领域:环境。检测对象包括:Self-contained closed-circuit breathing apparatus with compressed o…、Closed-circuit escape breathing apparatus、Self-contained compressed air breathing apparatus。
要点速览
- 认可编号: PCA AB 321
- 认可范围内方法数: 22
- 检测对象种类: 3
- 城市: Bytom, 波兰
- 认可编号
- AB 321
- 认可机构
- PCA
- 地址
- LABORATORIUM BADANIA i OPINIOWANIA SPRZĘTU, ul. Chorzowska 25, 41-902 Bytom
- 城市
- Bytom, 波兰
该实验室检测什么 (3)
- Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen — 10 项方法
- Closed-circuit escape breathing apparatus — 9 项方法
- Self-contained compressed air breathing apparatus — 3 项方法
认可范围 — 项检测方法 (22)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Leak tightness 范围 (-1000÷1000) Pa |
PN-EN 145: 2000 pkt. 7.7 | ||
| 2 | Closed-circuit escape breathing apparatus | Leak tightness 范围 (-1000÷1000) Pa |
PN-EN 13794:2005 pkt. 7.5.1; 7.5.2 | ||
| 3 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Gas supply 范围 (0,5÷120) dm3/min. |
PN-EN 145:2000 pkt. 7.7 | ||
| 4 | Closed-circuit escape breathing apparatus | Oxygen supply 范围 (0,5÷120) dm3/min. |
PN-EN 13794:2005 pkt. 7.14 | ||
| 5 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Relief valve opening pressure 范围 (0÷5000) Pa |
PN-EN 145:2000 pkt. 7.12 | ||
| 6 | Closed-circuit escape breathing apparatus | Relief valve opening pressure 范围 (0÷5000) Pa |
PN-EN 13794:2005 pkt. 7.7 | ||
| 7 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Operation of the feed valve 范围 (0,5÷120) dm3/min. |
PN-EN 145:2000 pkt. 7.7 | ||
| 8 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Properties of the pressure indicator 范围 (0÷30) MPa |
PN-EN 145:2000 pkt. 6.18 (bez badań eksploatacyjnych) | ||
| 9 | Closed-circuit escape breathing apparatus | Breathing resistance 范围 (-5000÷5000) Pa |
PN-EN 13794:2005 pkt. 7.12, pkt. 7.10 | ||
| 10 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Breathing bag volume 范围 od 0 dm 3 |
PN-EN 145:2000 pkt. 7.13 | ||
| 11 | Closed-circuit escape breathing apparatus | Breathing bag volume 范围 od 0 dm 3 |
PN-EN 13794:2005 pkt. 7.8 | ||
| 12 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Mass of the apparatus 范围 (0÷150) kg |
PN-EN 145:2000 pkt. 6.4 | ||
| 13 | Closed-circuit escape breathing apparatus | Mass of the apparatus 范围 (0÷150) kg |
PN-EN 13794:2005 pkt. 6.5 | ||
| 14 | Self-contained compressed air breathing apparatus | Mass of the apparatus 范围 (0÷150) kg |
PN-EN 137:2008 pkt. 6.6 | ||
| 15 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Physiological parameters CO2 范围 (0÷10) % obj. O2 范围 (0÷100) % obj. 温度 范围 (0÷120) 0C Opory oddechowe 范围 (-5000÷5000) Pa Urządzenie przepłukujące |
PN-EN 145:2000 +A1:2002 pkt. 7.8 | PN-EN 145:2000 pkt. 7.8.1 | PN-EN 145:2000 pkt. 6.22 | ||
| 16 | Closed-circuit escape breathing apparatus | CO2 operating efficiency 范围 (0÷10) % obj. O2 范围 (0÷100) % obj. 温度 范围 (0÷120) 0C Opory oddechowe 范围 (-5000÷5000) Pa |
PN-EN 13794:2005 pkt. 7.10 | ||
| 17 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | Performance tests | PN-EN 145:2000 pkt. 7.3 | ||
| 18 | Closed-circuit escape breathing apparatus | Performance tests | PN-EN 13794:2005 pkt. 7.16, Załącznik A | ||
| 19 | Self-contained compressed air breathing apparatus | Performance tests | PN-EN 137:2008 pkt. 7.11 | ||
| 20 | Self-contained closed-circuit breathing apparatus with compressed oxygen or a mixture of compressed oxygen and nitrogen | 耐热性 | PN-EN 145:2000 pkt. 7.4 | ||
| 21 | Closed-circuit escape breathing apparatus | 耐热性 | PN-EN 13794:2005 pkt. 7.9 | ||
| 22 | Self-contained compressed air breathing apparatus | 耐热性 | PN-EN 137:2008 pkt. 7.4.1.1.; 7.4.1.2; 7.4.2 | ||
引用标准 (23)
PN-EN 13794:2005 pkt. 6.5
PN-EN 13794:2005 pkt. 7.10
PN-EN 13794:2005 pkt. 7.12, pkt. 7.10
PN-EN 13794:2005 pkt. 7.14
PN-EN 13794:2005 pkt. 7.16, Załącznik A
PN-EN 13794:2005 pkt. 7.5.1; 7.5.2
PN-EN 13794:2005 pkt. 7.7
PN-EN 13794:2005 pkt. 7.8
PN-EN 13794:2005 pkt. 7.9
PN-EN 137:2008 pkt. 6.6
PN-EN 137:2008 pkt. 7.11
PN-EN 137:2008 pkt. 7.4.1.1.; 7.4.1.2; 7.4.2
PN-EN 145: 2000 pkt. 7.7
PN-EN 145:2000 +A1:2002 pkt. 7.8
PN-EN 145:2000 pkt. 6.18 (bez badań eksploatacyjnych)
PN-EN 145:2000 pkt. 6.22
PN-EN 145:2000 pkt. 6.4
PN-EN 145:2000 pkt. 7.12
PN-EN 145:2000 pkt. 7.13
PN-EN 145:2000 pkt. 7.3
PN-EN 145:2000 pkt. 7.4
PN-EN 145:2000 pkt. 7.7
PN-EN 145:2000 pkt. 7.8.1