🇵🇱 Polska Spółka Gazownictwa Sp. z o.o. PL
石油化工与燃料计量与校准水与废水
Polska Spółka Gazownictwa Sp. z o.o. 是由 PCA 认可的实验室,认可编号 AB 278(Tarnów,波兰)。认可范围涵盖 17 项检测方法,涉及以下领域:石油化工与燃料、计量与校准、水与废水。检测对象包括:Gaseous fuels: natural gas, gas mixtures、Diaphragm gas meters from 0,016 m3/h to 160 m3/h、Gas meter measuring sections、Gas meter volume conversion devices。最常用的技术:Gas chromatography with flame photometric detection (GC-FPD)、Gas chromatography with thermal conductivity detection (GC-TCD)、Gas chromatography with thermal conductivity detection (GC-TCD) and…。
要点速览
- 认可编号: PCA AB 278
- 认可范围内方法数: 17
- 检测对象种类: 13
- 所用技术数: 4
- 城市: Tarnów, 波兰
- 认可编号
- AB 278
- 认可机构
- PCA
- 地址
- ul. Wojciecha Bandrowskiego 16, 33-100 Tarnów, Oddział Wsparcia w Warszawie, ul. Krucza 6/14, 00-537 Warszawa
- 城市
- Tarnów, 波兰
该实验室检测什么 (13)
- Gaseous fuels: natural gas, gas mixtures — 5 项方法
- Diaphragm gas meters from 0,016 m3/h to 160 m3/h — 1 项方法
- Gas meter measuring sections — 1 项方法
- Gas meter volume conversion devices — 1 项方法
- Gas meter volume conversion devices, Pressure transmitters, Differential pressure transmitters, Platinum resistance thermometer sensors, Temperature transmitters — 1 项方法
- Gas volume converters E — 1 项方法
- Gaseous fuels: natural gas, biogas (biomethane), gas mixtures — 1 项方法
- Gaseous fuels: synthetic gas mixtures — 1 项方法
- Measuring orifice plates — 1 项方法
- Natural gas standard density transducers — 1 项方法
- Process chromatographic analysers — 1 项方法
- Rotary gas meters from 0,016 m3/h to 160 m3/h, from 1,30 m3/h to 283 m3/h — 1 项方法
- Turbine gas meters from 0,016 m3/h to 160 m3/h, from 0,16 m3/h to 6500 m3/h — 1 项方法
所用检测技术 (4)
- Gas chromatography with flame photometric detection (GC-FPD) — 1 项方法
- Gas chromatography with thermal conductivity detection (GC-TCD) — 1 项方法
- Gas chromatography with thermal conductivity detection (GC-TCD) and flame ionization detection (GC-FID) — 1 项方法
- Vapour condensation on a chilled mirror surface method — 1 项方法
认可范围 — 项检测方法 (17)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | Diaphragm gas meters from 0,016 m3/h to 160 m3/h | Indication errors, Pressure loss | PN-EN 1359:2017-11 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gm1 wydanie 3 z dnia 25.11.2025 r. | ||
| 2 | Rotary gas meters from 0,016 m3/h to 160 m3/h, from 1,30 m3/h to 283 m3/h | Indication errors, Pressure loss | PN-EN 12480:2018-06 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gr1 wydanie 3 z dnia 25.11.2025 r. | ||
| 3 | Turbine gas meters from 0,016 m3/h to 160 m3/h, from 0,16 m3/h to 6500 m3/h | Errors of indication, Pressure losses | PN-EN 12261:2024-06 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gt1 wydanie 3 z dnia 25.11.2025 r. | ||
| 4 | Gas meter measuring sections | Geometric parameters of the measuring sections: internal diameter (5 – 1076) mm external diameter do 1500 mm position of thermometer pockets do 5 m length do 50 m perpendicularity of the flange sealing faces to the axis of the sections (0 – 180)° roughness of the internal surface of the sections Ra (0,01 – 60) μm |
PB PPG/o 1 wydanie 8 z dnia 22.09.2023 r. | ||
| 5 | Measuring orifice plates | Geometric parameters of the orifice plate length do 100 mm internal diameter (5 – 1076) mm radius do 0,5 mm flatness (0,03 – 1,00) mm thickness do 50 mm external diameter do 1500 mm chamfer surface angle (0 – 90)° roughness parameter Ra of the inlet, outlet, bore and chamfer surfaces (0,01 – 200) μm coaxiality deviation (0 – 10) mm |
PB PPG/k1 wydanie 10 z dnia 22.09.2023 r. | ||
| 6 | Gaseous fuels: natural gas, gas mixtures | Gas composition in the extended range (N2, CO2, C1-C9, O2) azot (0,005 – 55) % CO2 (0,001 – 4) % C1 (37 – 100) % C2 (0,001 – 10,0) % C3 (0,001 – 5,0) % i-C4 (0,001 – 1) % n-C4 (0,001 – 1) % neo-C5 (0,0005 – 0,1) % i-C5 (0,001 – 0,1) % n-C5 (0,001 – 0,1) % C6 (0,0001 – 0,05) % C7 (0,0001 – 0,05) % C8 (0,0001 – 0,05) % C9 (0,0001 – 0,05) % O2 (0,002 – 0,2) % |
Gas chromatography with thermal conductivity detection (GC-TCD) and flame ionization detection (GC-FID) | PB PFC/ch 3 wydanie 2 z dnia 25.09.2023 r. | |
| 7 | Gaseous fuels: natural gas, gas mixtures | Gas composition in the range: azot (0,1 – 21,9) % CO2 (0,002 – 13,0) % C1 (72,89 – 100) % C2 (0,005 – 10,02) % C3 (0,005 – 13,0) % i-C4 (0,002 – 1) % n-C4 (0,002 – 1) % neo-C5 (0,002 – 0,1) % i-C5 (0,001 – 0,1) % n-C5 (0,001 – 0,1) % grupa C6+ (0,001 – 0,051) % O2 (0,01 – 0,2) % He (0,001 – 0,197)% H2 (0,001 – 23,0)% |
Gas chromatography with thermal conductivity detection (GC-TCD) | PB PFC/ch 4 wydanie 2 z dnia 5.09.2025 r. | |
| 8 | Gaseous fuels: natural gas, gas mixtures | Gaseous fuel parameters: gross calorific value net calorific value Wobbe index (higher and lower) density: normal relative |
PN-EN ISO 6976:2016-11 | ||
| 9 | Gaseous fuels: natural gas, gas mixtures | Gaseous fuel parameters: methane number |
PN-EN 16726:2015+A1:2018 | ||
| 10 | Gaseous fuels: natural gas, gas mixtures | Water dew point temperature | Vapour condensation on a chilled mirror surface method | PB PFC/pr 1 wydanie 6 z dnia 25.09.2023 r. | |
| 11 | Process chromatographic analysers | Analytical trueness | PB PFC/ch 2 wydanie 3 z dnia 25.09.2023 r. | PN-EN ISO 10723:2005 p. 6.1, 6.4 Załącznik A p. A1 | ||
| 12 | Natural gas standard density transducers | Density of mixtures and pure gases 范围 (0,717 – 1,250) kg/m3 |
PB PFC/de 1 wydanie 3 z dnia 25.09.2023 r. | ||
| 13 | Gaseous fuels: synthetic gas mixtures | THT concentration in gas 范围 (1,5 - 100) mg/m3 Zakres z przeliczenia (0,38 – 25,45) ppm |
Gas chromatography with flame photometric detection (GC-FPD) | PB PFC/THT wydanie 2 z dnia 25.09.2023 r. | |
| 14 | Gaseous fuels: natural gas, biogas (biomethane), gas mixtures | 化学与物理检测用样品采集 | PB PFC/sa 1 wydanie 6 z dnia 25.09.2023 r. | ||
| 15 | Gas meter volume conversion devices, Pressure transmitters, Differential pressure transmitters, Platinum resistance thermometer sensors, Temperature transmitters | Metrological and design properties (tests at the laboratory premises) | ZN-G-4007:2001 | PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r. | ||
| 16 | Gas meter volume conversion devices | Metrological and design properties (tests at the installation site) | ZN-G-4007:2001 | PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r. | ||
| 17 | Gas volume converters E | Metrological and design properties | PN-EN 12405-1 | ||
引用标准 (22)
PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r.
PB PFC/THT wydanie 2 z dnia 25.09.2023 r.
PB PFC/ch 2 wydanie 3 z dnia 25.09.2023 r.
PB PFC/ch 3 wydanie 2 z dnia 25.09.2023 r.
PB PFC/ch 4 wydanie 2 z dnia 5.09.2025 r.
PB PFC/de 1 wydanie 3 z dnia 25.09.2023 r.
PB PFC/pr 1 wydanie 6 z dnia 25.09.2023 r.
PB PFC/sa 1 wydanie 6 z dnia 25.09.2023 r.
PB PPG/k1 wydanie 10 z dnia 22.09.2023 r.
PB PPG/o 1 wydanie 8 z dnia 22.09.2023 r.
PB PPO/gm1 wydanie 3 z dnia 25.11.2025 r.
PB PPO/gr1 wydanie 3 z dnia 25.11.2025 r.
PB PPO/gt1 wydanie 3 z dnia 25.11.2025 r.
PN-EN 12261:2024-06
PN-EN 12405-1
PN-EN 12480:2018-06
PN-EN 1359:2017-11
PN-EN 16726:2015+A1:2018
PN-EN ISO 10723:2005 p. 6.1, 6.4 Załącznik A p. A1
PN-EN ISO 6976:2016-11
Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298)
ZN-G-4007:2001