{"lab":{"_id":"69ad52a3de79e566650fb195","accr_number":"AB 278","country":"PL","accr_body":"PCA","address":"ul. Wojciecha Bandrowskiego 16, 33-100 Tarnów, Oddział Wsparcia w Warszawie, ul. Krucza 6/14, 00-537 Warszawa","categories":["petro","metrology","water"],"city":"Tarnów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":17,"name":"Polska Spółka Gazownictwa Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_278.pdf"],"scope_summary":"","search_text":"polska spółka gazownictwa sp. z o.o. ul. wojciecha bandrowskiego 16, 33-100 tarnów, oddział wsparcia w warszawie, ul. krucza 6/14, 00-537 warszawa other metrology materials petro water","status":"active","updated_at":"2026-03-08T14:51:07.404Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:07.404Z","location":{"type":"Point","coordinates":[20.9858,50.0121]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20278,podmiot.html","fields_of_testing":[{"codes":"C/10/P","pl":"Badania chemiczne i pobieranie próbek paliw gazowych","en":"Chemical tests of fuels (gas) sampling, laboratories accredited for sampling"},{"codes":"N/10/P","pl":"Badania właściwości fizycznych i pobieranie próbek paliw gazowych","en":"Tests of physical properties of fuels (gas) sampling, laboratories accredited for sampling"},{"codes":"N/38","pl":"Badania właściwości fizycznych wyposażenia – w tym instalacji jądrowych","en":"Tests of physical properties of equipment – including nuclear installations"}],"issue":{"no":"30","date":"08.01.2026"},"parse_date":"2026-07-20T07:09:58.346Z","parse_source":"script-pdfplumber","map_coord":[50.007523,20.980328],"map_geo":"nominatim-street","has_en":true,"category_counts":{"petro":7,"other":6,"metrology":4,"water":1},"category_scores":{"petro":2.72,"other":2,"metrology":0.89,"water":0.06},"has_zh":true},"methods":[{"_id":"6a5dc9c6f1c10c8ce826058d","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Gazomierze miechowe od 0,016 m3/h do 160 m3/h","test_object_en":"Diaphragm gas meters from 0,016 m3/h to 160 m3/h","methodology":"Błędy wskazań, Strata ciśnienia","methodology_en":"Indication errors, Pressure loss","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Błędy wskazań, Strata ciśnienia","reference":"PN-EN 1359:2017-11 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gm1 wydanie 3 z dnia 25.11.2025 r.","norm_bases":["PN-EN 1359:2017-11","Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298)","PB PPO/gm1 wydanie 3 z dnia 25.11.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazomierze miechowe od 0,016 m3/h do 160 m3/h Błędy wskazań, Strata ciśnienia PN-EN 1359:2017-11 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gm1 wydanie 3 z dnia 25.11.2025 r. Gazomierze miechowe od 0,016 m3/h do 160 m3/h Bledy wskazan, Strata cisnienia PN-EN 1359:2017-11 | Rozporzadzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gm1 wydanie 3 z dnia 25.11.2025 r.","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Diaphragm gas meters from 0,016 m3/h to 160 m3/h Indication errors, Pressure loss PN-EN 1359:2017-11 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gm1 wydanie 3 z dnia 25.11.2025 r."},{"_id":"6a5dc9c6f1c10c8ce826058e","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Gazomierze rotorowe od 0,016 m3/h do 160 m3/h, od 1,30 m3/h do 283 m3/h","test_object_en":"Rotary gas meters from 0,016 m3/h to 160 m3/h, from 1,30 m3/h to 283 m3/h","methodology":"Błędy wskazań, Strata ciśnienia","methodology_en":"Indication errors, Pressure loss","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Błędy wskazań, Strata ciśnienia","reference":"PN-EN 12480:2018-06 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gr1 wydanie 3 z dnia 25.11.2025 r.","norm_bases":["PN-EN 12480:2018-06","Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298)","PB PPO/gr1 wydanie 3 z dnia 25.11.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazomierze rotorowe od 0,016 m3/h do 160 m3/h, od 1,30 m3/h do 283 m3/h Błędy wskazań, Strata ciśnienia PN-EN 12480:2018-06 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gr1 wydanie 3 z dnia 25.11.2025 r. Gazomierze rotorowe od 0,016 m3/h do 160 m3/h, od 1,30 m3/h do 283 m3/h Bledy wskazan, Strata cisnienia PN-EN 12480:2018-06 | Rozporzadzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gr1 wydanie 3 z dnia 25.11.2025 r.","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rotary gas meters from 0,016 m3/h to 160 m3/h, from 1,30 m3/h to 283 m3/h Indication errors, Pressure loss PN-EN 12480:2018-06 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gr1 wydanie 3 z dnia 25.11.2025 r."},{"_id":"6a5dc9c6f1c10c8ce826058f","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Gazomierze turbinowe od 0,016 m3/h do 160 m3/h, od 0,16 m3/h do 6500 m3/h","test_object_en":"Turbine gas meters from 0,016 m3/h to 160 m3/h, from 0,16 m3/h to 6500 m3/h","methodology":"Błędy wskazań, Straty ciśnienia","methodology_en":"Errors of indication, Pressure losses","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Błędy wskazań, Straty ciśnienia","reference":"PN-EN 12261:2024-06 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gt1 wydanie 3 z dnia 25.11.2025 r.","norm_bases":["PN-EN 12261:2024-06","Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298)","PB PPO/gt1 wydanie 3 z dnia 25.11.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazomierze turbinowe od 0,016 m3/h do 160 m3/h, od 0,16 m3/h do 6500 m3/h Błędy wskazań, Straty ciśnienia PN-EN 12261:2024-06 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gt1 wydanie 3 z dnia 25.11.2025 r. Gazomierze turbinowe od 0,016 m3/h do 160 m3/h, od 0,16 m3/h do 6500 m3/h Bledy wskazan, Straty cisnienia PN-EN 12261:2024-06 | Rozporzadzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gt1 wydanie 3 z dnia 25.11.2025 r.","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Turbine gas meters from 0,016 m3/h to 160 m3/h, from 0,16 m3/h to 6500 m3/h Errors of indication, Pressure losses PN-EN 12261:2024-06 | Rozporządzenie Ministra Gospodarki z dnia 28 grudnia 2007 r. (Dz.U. z 2019 poz. 1298) | PB PPO/gt1 wydanie 3 z dnia 25.11.2025 r."},{"_id":"6a5dc9c6f1c10c8ce8260590","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Odcinki pomiarowe gazomierzy","test_object_en":"Gas meter measuring sections","methodology":"Parametry geometryczne odcinków pomiarowych:","methodology_en":"Geometric parameters of the measuring sections:","parameters":[{"name":"średnica wewnętrzna","range":"(5 – 1076) mm"},{"name":"średnica zewnętrzna","range":"do 1500 mm"},{"name":"położenie gniazd termometrycznych","range":"do 5 m"},{"name":"długość","range":"do 50 m"},{"name":"prostopadłość powierzchni uszczelniających kołnierzy do osi odcinków","range":"(0 – 180)°"},{"name":"chropowatość powierzchni wewnętrznej odcinków Ra","range":"(0,01 – 60) μm"}],"parameters_en":[{"name":"internal diameter","range":"(5 – 1076) mm"},{"name":"external diameter","range":"do 1500 mm"},{"name":"position of thermometer pockets","range":"do 5 m"},{"name":"length","range":"do 50 m"},{"name":"perpendicularity of the flange sealing faces to the axis of the sections","range":"(0 – 180)°"},{"name":"roughness of the internal surface of the sections Ra","range":"(0,01 – 60) μm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Parametry geometryczne odcinków pomiarowych:\nZakres:\nśrednica wewnętrzna (5 – 1076) mm\nśrednica zewnętrzna do 1500 mm\npołożenie gniazd termometrycznych do 5 m\ndługość do 50 m\nprostopadłość powierzchni uszczelniających kołnierzy do osi odcinków (0 – 180)°\nchropowatość powierzchni wewnętrznej odcinków Ra (0,01 – 60) μm","reference":"PB PPG/o 1 wydanie 8 z dnia 22.09.2023 r.","norm_bases":["PB PPG/o 1 wydanie 8 z dnia 22.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odcinki pomiarowe gazomierzy Parametry geometryczne odcinków pomiarowych:\nZakres:\nśrednica wewnętrzna (5 – 1076) mm\nśrednica zewnętrzna do 1500 mm\npołożenie gniazd termometrycznych do 5 m\ndługość do 50 m\nprostopadłość powierzchni uszczelniających kołnierzy do osi odcinków (0 – 180)°\nchropowatość powierzchni wewnętrznej odcinków Ra (0,01 – 60) μm PB PPG/o 1 wydanie 8 z dnia 22.09.2023 r. Odcinki pomiarowe gazomierzy Parametry geometryczne odcinkow pomiarowych:\nZakres:\nsrednica wewnetrzna (5 – 1076) mm\nsrednica zewnetrzna do 1500 mm\npolozenie gniazd termometrycznych do 5 m\ndlugosc do 50 m\nprostopadlosc powierzchni uszczelniajacych kolnierzy do osi odcinkow (0 – 180)°\nchropowatosc powierzchni wewnetrznej odcinkow Ra (0,01 – 60) μm PB PPG/o 1 wydanie 8 z dnia 22.09.2023 r.","categories":["metrology"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas meter measuring sections Geometric parameters of the measuring sections: internal diameter external diameter position of thermometer pockets length perpendicularity of the flange sealing faces to the axis of the sections roughness of the internal surface of the sections Ra PB PPG/o 1 wydanie 8 z dnia 22.09.2023 r.","parameters_zh":[{"name":"średnica wewnętrzna","range":"(5 – 1076) mm"},{"name":"średnica zewnętrzna","range":"do 1500 mm"},{"name":"położenie gniazd termometrycznych","range":"do 5 m"},{"name":"长度","range":"do 50 m"},{"name":"prostopadłość powierzchni uszczelniających kołnierzy do osi odcinków","range":"(0 – 180)°"},{"name":"chropowatość powierzchni wewnętrznej odcinków Ra","range":"(0,01 – 60) μm"}],"search_zh":"长度 PB PPG/o 1 wydanie 8 z dnia 22.09.2023 r."},{"_id":"6a5dc9c6f1c10c8ce8260591","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Kryzy pomiarowe","test_object_en":"Measuring orifice plates","methodology":"Parametry geometryczne kryzy","methodology_en":"Geometric parameters of the orifice plate","parameters":[{"name":"długość","range":"do 100 mm"},{"name":"średnica wewnętrzna","range":"(5 – 1076) mm"},{"name":"promień","range":"do 0,5 mm"},{"name":"płaskość","range":"(0,03 – 1,00) mm"},{"name":"grubość","range":"do 50 mm"},{"name":"średnica zewnętrzna","range":"do 1500 mm"},{"name":"kąt powierzchni sfazowania","range":"(0 – 90)°"},{"name":"parametr chropowatości Ra powierzchni dopływowej, odpływowej, otworu i sfazowania","range":"(0,01 – 200) μm"},{"name":"odchyłka współosiowości","range":"(0 – 10) mm"}],"parameters_en":[{"name":"length","range":"do 100 mm"},{"name":"internal diameter","range":"(5 – 1076) mm"},{"name":"radius","range":"do 0,5 mm"},{"name":"flatness","range":"(0,03 – 1,00) mm"},{"name":"thickness","range":"do 50 mm"},{"name":"external diameter","range":"do 1500 mm"},{"name":"chamfer surface angle","range":"(0 – 90)°"},{"name":"roughness parameter Ra of the inlet, outlet, bore and chamfer surfaces","range":"(0,01 – 200) μm"},{"name":"coaxiality deviation","range":"(0 – 10) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Parametry geometryczne kryzy\nZakres:\ndługość do 100 mm\nśrednica wewnętrzna (5 – 1076) mm\npromień do 0,5 mm\npłaskość (0,03 – 1,00) mm\ngrubość do 50 mm\nśrednica zewnętrzna do 1500 mm\nkąt powierzchni sfazowania (0 – 90)°\nparametr chropowatości Ra powierzchni dopływowej, odpływowej, otworu i sfazowania (0,01 – 200) μm\nodchyłka współosiowości (0 – 10) mm","reference":"PB PPG/k1 wydanie 10 z dnia 22.09.2023 r.","norm_bases":["PB PPG/k1 wydanie 10 z dnia 22.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kryzy pomiarowe Parametry geometryczne kryzy\nZakres:\ndługość do 100 mm\nśrednica wewnętrzna (5 – 1076) mm\npromień do 0,5 mm\npłaskość (0,03 – 1,00) mm\ngrubość do 50 mm\nśrednica zewnętrzna do 1500 mm\nkąt powierzchni sfazowania (0 – 90)°\nparametr chropowatości Ra powierzchni dopływowej, odpływowej, otworu i sfazowania (0,01 – 200) μm\nodchyłka współosiowości (0 – 10) mm PB PPG/k1 wydanie 10 z dnia 22.09.2023 r. Kryzy pomiarowe Parametry geometryczne kryzy\nZakres:\ndlugosc do 100 mm\nsrednica wewnetrzna (5 – 1076) mm\npromien do 0,5 mm\nplaskosc (0,03 – 1,00) mm\ngrubosc do 50 mm\nsrednica zewnetrzna do 1500 mm\nkat powierzchni sfazowania (0 – 90)°\nparametr chropowatosci Ra powierzchni doplywowej, odplywowej, otworu i sfazowania (0,01 – 200) μm\nodchylka wspolosiowosci (0 – 10) mm PB PPG/k1 wydanie 10 z dnia 22.09.2023 r.","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measuring orifice plates Geometric parameters of the orifice plate length internal diameter radius flatness thickness external diameter chamfer surface angle roughness parameter Ra of the inlet, outlet, bore and chamfer surfaces coaxiality deviation PB PPG/k1 wydanie 10 z dnia 22.09.2023 r.","parameters_zh":[{"name":"长度","range":"do 100 mm"},{"name":"średnica wewnętrzna","range":"(5 – 1076) mm"},{"name":"promień","range":"do 0,5 mm"},{"name":"płaskość","range":"(0,03 – 1,00) mm"},{"name":"grubość","range":"do 50 mm"},{"name":"średnica zewnętrzna","range":"do 1500 mm"},{"name":"kąt powierzchni sfazowania","range":"(0 – 90)°"},{"name":"parametr chropowatości Ra powierzchni dopływowej, odpływowej, otworu i sfazowania","range":"(0,01 – 200) μm"},{"name":"odchyłka współosiowości","range":"(0 – 10) mm"}],"search_zh":"长度 PB PPG/k1 wydanie 10 z dnia 22.09.2023 r."},{"_id":"6a5dc9c6f1c10c8ce8260592","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"Skład gazu w zakresie rozszerzonym (N2, CO2, C1-C9, O2)","methodology_en":"Gas composition in the extended range (N2, CO2, C1-C9, O2)","parameters":[{"name":"azot","range":"(0,005 – 55) %"},{"name":"CO2","range":"(0,001 – 4) %"},{"name":"C1","range":"(37 – 100) %"},{"name":"C2","range":"(0,001 – 10,0) %"},{"name":"C3","range":"(0,001 – 5,0) %"},{"name":"i-C4","range":"(0,001 – 1) %"},{"name":"n-C4","range":"(0,001 – 1) %"},{"name":"neo-C5","range":"(0,0005 – 0,1) %"},{"name":"i-C5","range":"(0,001 – 0,1) %"},{"name":"n-C5","range":"(0,001 – 0,1) %"},{"name":"C6","range":"(0,0001 – 0,05) %"},{"name":"C7","range":"(0,0001 – 0,05) %"},{"name":"C8","range":"(0,0001 – 0,05) %"},{"name":"C9","range":"(0,0001 – 0,05) %"},{"name":"O2","range":"(0,002 – 0,2) %"}],"parameters_en":[{"name":"nitrogen","range":"(0,005 – 55) %"},{"name":"CO2","range":"(0,001 – 4) %"},{"name":"C1","range":"(37 – 100) %"},{"name":"C2","range":"(0,001 – 10,0) %"},{"name":"C3","range":"(0,001 – 5,0) %"},{"name":"i-C4","range":"(0,001 – 1) %"},{"name":"n-C4","range":"(0,001 – 1) %"},{"name":"neo-C5","range":"(0,0005 – 0,1) %"},{"name":"i-C5","range":"(0,001 – 0,1) %"},{"name":"n-C5","range":"(0,001 – 0,1) %"},{"name":"C6","range":"(0,0001 – 0,05) %"},{"name":"C7","range":"(0,0001 – 0,05) %"},{"name":"C8","range":"(0,0001 – 0,05) %"},{"name":"C9","range":"(0,0001 – 0,05) %"},{"name":"O2","range":"(0,002 – 0,2) %"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktomertyczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktomertyczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD) and flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Skład gazu w zakresie rozszerzonym (N2, CO2, C1-C9, O2)\nZakres:\nazot (0,005 – 55) %\nCO2 (0,001 – 4) %\nC1 (37 – 100) %\nC2 (0,001 – 10,0) %\nC3 (0,001 – 5,0) %\ni-C4 (0,001 – 1) %\nn-C4 (0,001 – 1) %\nneo-C5 (0,0005 – 0,1) %\ni-C5 (0,001 – 0,1) %\nn-C5 (0,001 – 0,1) %\nC6 (0,0001 – 0,05) %\nC7 (0,0001 – 0,05) %\nC8 (0,0001 – 0,05) %\nC9 (0,0001 – 0,05) %\nO2 (0,002 – 0,2) %\nMetoda chromatografii gazowej z detekcją termokonduktomertyczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","reference":"PB PFC/ch 3 wydanie 2 z dnia 25.09.2023 r.","norm_bases":["PB PFC/ch 3 wydanie 2 z dnia 25.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe Skład gazu w zakresie rozszerzonym (N2, CO2, C1-C9, O2)\nZakres:\nazot (0,005 – 55) %\nCO2 (0,001 – 4) %\nC1 (37 – 100) %\nC2 (0,001 – 10,0) %\nC3 (0,001 – 5,0) %\ni-C4 (0,001 – 1) %\nn-C4 (0,001 – 1) %\nneo-C5 (0,0005 – 0,1) %\ni-C5 (0,001 – 0,1) %\nn-C5 (0,001 – 0,1) %\nC6 (0,0001 – 0,05) %\nC7 (0,0001 – 0,05) %\nC8 (0,0001 – 0,05) %\nC9 (0,0001 – 0,05) %\nO2 (0,002 – 0,2) %\nMetoda chromatografii gazowej z detekcją termokonduktomertyczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID) PB PFC/ch 3 wydanie 2 z dnia 25.09.2023 r. Paliwa gazowe: gaz ziemny, mieszaniny gazowe Sklad gazu w zakresie rozszerzonym (N2, CO2, C1-C9, O2)\nZakres:\nazot (0,005 – 55) %\nCO2 (0,001 – 4) %\nC1 (37 – 100) %\nC2 (0,001 – 10,0) %\nC3 (0,001 – 5,0) %\ni-C4 (0,001 – 1) %\nn-C4 (0,001 – 1) %\nneo-C5 (0,0005 – 0,1) %\ni-C5 (0,001 – 0,1) %\nn-C5 (0,001 – 0,1) %\nC6 (0,0001 – 0,05) %\nC7 (0,0001 – 0,05) %\nC8 (0,0001 – 0,05) %\nC9 (0,0001 – 0,05) %\nO2 (0,002 – 0,2) %\nMetoda chromatografii gazowej z detekcja termokonduktomertyczna (GC-TCD) i plomieniowo-jonizacyjna (GC-FID) PB PFC/ch 3 wydanie 2 z dnia 25.09.2023 r.","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas, gas mixtures Gas composition in the extended range (N2, CO2, C1-C9, O2) Gas chromatography with thermal conductivity detection (GC-TCD) and flame ionization detection (GC-FID) nitrogen CO2 C1 C2 C3 i-C4 n-C4 neo-C5 i-C5 n-C5 C6 C7 C8 C9 O2 PB PFC/ch 3 wydanie 2 z dnia 25.09.2023 r.","parameters_zh":[{"name":"氮","range":"(0,005 – 55) %"},{"name":"CO2","range":"(0,001 – 4) %"},{"name":"C1","range":"(37 – 100) %"},{"name":"C2","range":"(0,001 – 10,0) %"},{"name":"C3","range":"(0,001 – 5,0) %"},{"name":"i-C4","range":"(0,001 – 1) %"},{"name":"n-C4","range":"(0,001 – 1) %"},{"name":"新戊烷（neo-C5）","range":"(0,0005 – 0,1) %"},{"name":"i-C5","range":"(0,001 – 0,1) %"},{"name":"n-C5","range":"(0,001 – 0,1) %"},{"name":"C6","range":"(0,0001 – 0,05) %"},{"name":"C7","range":"(0,0001 – 0,05) %"},{"name":"C8","range":"(0,0001 – 0,05) %"},{"name":"C9","range":"(0,0001 – 0,05) %"},{"name":"O2","range":"(0,002 – 0,2) %"}],"search_zh":"气体燃料：天然气、混合气体 氮 CO2 新戊烷（neo-C5） O2 PB PFC/ch 3 wydanie 2 z dnia 25.09.2023 r.","test_object_zh":"气体燃料：天然气、混合气体"},{"_id":"6a5dc9c6f1c10c8ce8260593","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"Skład gazu w zakresie:","methodology_en":"Gas composition in the range:","parameters":[{"name":"azot","range":"(0,1 – 21,9) %"},{"name":"CO2","range":"(0,002 – 13,0) %"},{"name":"C1","range":"(72,89 – 100) %"},{"name":"C2","range":"(0,005 – 10,02) %"},{"name":"C3","range":"(0,005 – 13,0) %"},{"name":"i-C4","range":"(0,002 – 1) %"},{"name":"n-C4","range":"(0,002 – 1) %"},{"name":"neo-C5","range":"(0,002 – 0,1) %"},{"name":"i-C5","range":"(0,001 – 0,1) %"},{"name":"n-C5","range":"(0,001 – 0,1) %"},{"name":"grupa C6+","range":"(0,001 – 0,051) %"},{"name":"O2","range":"(0,01 – 0,2) %"},{"name":"He","range":"(0,001 – 0,197)%"},{"name":"H2","range":"(0,001 – 23,0)%"}],"parameters_en":[{"name":"nitrogen","range":"(0,1 – 21,9) %"},{"name":"CO2","range":"(0,002 – 13,0) %"},{"name":"C1","range":"(72,89 – 100) %"},{"name":"C2","range":"(0,005 – 10,02) %"},{"name":"C3","range":"(0,005 – 13,0) %"},{"name":"i-C4","range":"(0,002 – 1) %"},{"name":"n-C4","range":"(0,002 – 1) %"},{"name":"neo-C5","range":"(0,002 – 0,1) %"},{"name":"i-C5","range":"(0,001 – 0,1) %"},{"name":"n-C5","range":"(0,001 – 0,1) %"},{"name":"C6+ group","range":"(0,001 – 0,051) %"},{"name":"O2","range":"(0,01 – 0,2) %"},{"name":"He","range":"(0,001 – 0,197)%"},{"name":"H2","range":"(0,001 – 23,0)%"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD)","computed":[],"computed_en":[],"activity":"Skład gazu w zakresie:\nZakres:\nazot (0,1 – 21,9) %\nCO2 (0,002 – 13,0) %\nC1 (72,89 – 100) %\nC2 (0,005 – 10,02) %\nC3 (0,005 – 13,0) %\ni-C4 (0,002 – 1) %\nn-C4 (0,002 – 1) %\nneo-C5 (0,002 – 0,1) %\ni-C5 (0,001 – 0,1) %\nn-C5 (0,001 – 0,1) %\ngrupa C6+ (0,001 – 0,051) %\nO2 (0,01 – 0,2) %\nHe (0,001 – 0,197)%\nH2 (0,001 – 23,0)%\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"PB PFC/ch 4 wydanie 2 z dnia 5.09.2025 r.","norm_bases":["PB PFC/ch 4 wydanie 2 z dnia 5.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe Skład gazu w zakresie:\nZakres:\nazot (0,1 – 21,9) %\nCO2 (0,002 – 13,0) %\nC1 (72,89 – 100) %\nC2 (0,005 – 10,02) %\nC3 (0,005 – 13,0) %\ni-C4 (0,002 – 1) %\nn-C4 (0,002 – 1) %\nneo-C5 (0,002 – 0,1) %\ni-C5 (0,001 – 0,1) %\nn-C5 (0,001 – 0,1) %\ngrupa C6+ (0,001 – 0,051) %\nO2 (0,01 – 0,2) %\nHe (0,001 – 0,197)%\nH2 (0,001 – 23,0)%\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) PB PFC/ch 4 wydanie 2 z dnia 5.09.2025 r. Paliwa gazowe: gaz ziemny, mieszaniny gazowe Sklad gazu w zakresie:\nZakres:\nazot (0,1 – 21,9) %\nCO2 (0,002 – 13,0) %\nC1 (72,89 – 100) %\nC2 (0,005 – 10,02) %\nC3 (0,005 – 13,0) %\ni-C4 (0,002 – 1) %\nn-C4 (0,002 – 1) %\nneo-C5 (0,002 – 0,1) %\ni-C5 (0,001 – 0,1) %\nn-C5 (0,001 – 0,1) %\ngrupa C6+ (0,001 – 0,051) %\nO2 (0,01 – 0,2) %\nHe (0,001 – 0,197)%\nH2 (0,001 – 23,0)%\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) PB PFC/ch 4 wydanie 2 z dnia 5.09.2025 r.","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas, gas mixtures Gas composition in the range: Gas chromatography with thermal conductivity detection (GC-TCD) nitrogen CO2 C1 C2 C3 i-C4 n-C4 neo-C5 i-C5 n-C5 C6+ group O2 He H2 PB PFC/ch 4 wydanie 2 z dnia 5.09.2025 r.","parameters_zh":[{"name":"氮","range":"(0,1 – 21,9) %"},{"name":"CO2","range":"(0,002 – 13,0) %"},{"name":"C1","range":"(72,89 – 100) %"},{"name":"C2","range":"(0,005 – 10,02) %"},{"name":"C3","range":"(0,005 – 13,0) %"},{"name":"i-C4","range":"(0,002 – 1) %"},{"name":"n-C4","range":"(0,002 – 1) %"},{"name":"新戊烷（neo-C5）","range":"(0,002 – 0,1) %"},{"name":"i-C5","range":"(0,001 – 0,1) %"},{"name":"n-C5","range":"(0,001 – 0,1) %"},{"name":"grupa C6+","range":"(0,001 – 0,051) %"},{"name":"O2","range":"(0,01 – 0,2) %"},{"name":"He","range":"(0,001 – 0,197)%"},{"name":"H2","range":"(0,001 – 23,0)%"}],"search_zh":"气体燃料：天然气、混合气体 气相色谱-热导检测法（GC-TCD） 氮 CO2 新戊烷（neo-C5） O2 PB PFC/ch 4 wydanie 2 z dnia 5.09.2025 r.","technique_zh":"气相色谱-热导检测法（GC-TCD）","test_object_zh":"气体燃料：天然气、混合气体"},{"_id":"6a5dc9c6f1c10c8ce8260594","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"Parametry paliwa gazowego:","methodology_en":"Gaseous fuel parameters:","parameters":[{"name":"ciepło spalania"},{"name":"wartość opałowa"},{"name":"liczba Wobbego (górna i dolna)"},{"name":"gęstość: normalna względna"}],"parameters_en":[{"name":"gross calorific value"},{"name":"net calorific value"},{"name":"Wobbe index (higher and lower)"},{"name":"density: normal relative"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Parametry paliwa gazowego:\nZakres:\nciepło spalania\nwartość opałowa\nliczba Wobbego (górna i dolna)\ngęstość: normalna względna","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe Parametry paliwa gazowego:\nZakres:\nciepło spalania\nwartość opałowa\nliczba Wobbego (górna i dolna)\ngęstość: normalna względna PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny, mieszaniny gazowe Parametry paliwa gazowego:\nZakres:\ncieplo spalania\nwartosc opalowa\nliczba Wobbego (gorna i dolna)\ngestosc: normalna wzgledna PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas, gas mixtures Gaseous fuel parameters: gross calorific value net calorific value Wobbe index (higher and lower) density: normal relative PN-EN ISO 6976:2016-11","parameters_zh":[{"name":"ciepło spalania"},{"name":"低位发热量"},{"name":"liczba Wobbego (górna i dolna)"},{"name":"gęstość: normalna względna"}],"search_zh":"气体燃料：天然气、混合气体 低位发热量 PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：天然气、混合气体"},{"_id":"6a5dc9c6f1c10c8ce8260595","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"Parametry paliwa gazowego:","methodology_en":"Gaseous fuel parameters:","parameters":[{"name":"liczba metanowa"}],"parameters_en":[{"name":"methane number"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Parametry paliwa gazowego:\nliczba metanowa","reference":"PN-EN 16726:2015+A1:2018","norm_bases":["PN-EN 16726:2015+A1:2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe Parametry paliwa gazowego:\nliczba metanowa PN-EN 16726:2015+A1:2018 Paliwa gazowe: gaz ziemny, mieszaniny gazowe Parametry paliwa gazowego:\nliczba metanowa PN-EN 16726:2015+A1:2018","categories":["petro"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas, gas mixtures Gaseous fuel parameters: methane number PN-EN 16726:2015+A1:2018","search_zh":"气体燃料：天然气、混合气体 PN-EN 16726:2015+A1:2018","test_object_zh":"气体燃料：天然气、混合气体"},{"_id":"6a5dc9c6f1c10c8ce8260596","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, gas mixtures","methodology":"Temperatura punktu rosy wody","methodology_en":"Water dew point temperature","parameters":[],"parameters_en":[],"technique":"Metoda kondensacji par na chłodzonej powierzchni lustra","techniques":["Metoda kondensacji par na chłodzonej powierzchni lustra"],"technique_en":"Vapour condensation on a chilled mirror surface method","computed":[],"computed_en":[],"activity":"Temperatura punktu rosy wody\nMetoda kondensacji par na chłodzonej powierzchni lustra","reference":"PB PFC/pr 1 wydanie 6 z dnia 25.09.2023 r.","norm_bases":["PB PFC/pr 1 wydanie 6 z dnia 25.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, mieszaniny gazowe Temperatura punktu rosy wody\nMetoda kondensacji par na chłodzonej powierzchni lustra PB PFC/pr 1 wydanie 6 z dnia 25.09.2023 r. Paliwa gazowe: gaz ziemny, mieszaniny gazowe Temperatura punktu rosy wody\nMetoda kondensacji par na chlodzonej powierzchni lustra PB PFC/pr 1 wydanie 6 z dnia 25.09.2023 r.","categories":["petro","water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas, gas mixtures Water dew point temperature Vapour condensation on a chilled mirror surface method PB PFC/pr 1 wydanie 6 z dnia 25.09.2023 r.","search_zh":"气体燃料：天然气、混合气体 水露点温度 冷却镜面凝露法 PB PFC/pr 1 wydanie 6 z dnia 25.09.2023 r.","test_object_zh":"气体燃料：天然气、混合气体","methodology_zh":"水露点温度","technique_zh":"冷却镜面凝露法"},{"_id":"6a5dc9c6f1c10c8ce8260597","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Procesowe analizatory chromatograficzne","test_object_en":"Process chromatographic analysers","methodology":"Poprawność analityczna","methodology_en":"Analytical trueness","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poprawność analityczna","reference":"PB PFC/ch 2 wydanie 3 z dnia 25.09.2023 r. | PN-EN ISO 10723:2005 p. 6.1, 6.4 Załącznik A p. A1","norm_bases":["PB PFC/ch 2 wydanie 3 z dnia 25.09.2023 r.","PN-EN ISO 10723:2005 p. 6.1, 6.4 Załącznik A p. A1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Procesowe analizatory chromatograficzne Poprawność analityczna PB PFC/ch 2 wydanie 3 z dnia 25.09.2023 r. | PN-EN ISO 10723:2005 p. 6.1, 6.4 Załącznik A p. A1 Procesowe analizatory chromatograficzne Poprawnosc analityczna PB PFC/ch 2 wydanie 3 z dnia 25.09.2023 r. | PN-EN ISO 10723:2005 p. 6.1, 6.4 Zalacznik A p. A1","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Process chromatographic analysers Analytical trueness PB PFC/ch 2 wydanie 3 z dnia 25.09.2023 r. | PN-EN ISO 10723:2005 p. 6.1, 6.4 Załącznik A p. A1"},{"_id":"6a5dc9c6f1c10c8ce8260598","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Przetworniki gęstości normalnej gazów ziemnych","test_object_en":"Natural gas standard density transducers","methodology":"Gęstość mieszanin i gazów czystych","methodology_en":"Density of mixtures and pure gases","parameters":[{"name":"Zakres","range":"(0,717 – 1,250) kg/m3"}],"parameters_en":[{"name":"Range","range":"(0,717 – 1,250) kg/m3"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość mieszanin i gazów czystych\nZakres (0,717 – 1,250) kg/m3","reference":"PB PFC/de 1 wydanie 3 z dnia 25.09.2023 r.","norm_bases":["PB PFC/de 1 wydanie 3 z dnia 25.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przetworniki gęstości normalnej gazów ziemnych Gęstość mieszanin i gazów czystych\nZakres (0,717 – 1,250) kg/m3 PB PFC/de 1 wydanie 3 z dnia 25.09.2023 r. Przetworniki gestosci normalnej gazow ziemnych Gestosc mieszanin i gazow czystych\nZakres (0,717 – 1,250) kg/m3 PB PFC/de 1 wydanie 3 z dnia 25.09.2023 r.","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Natural gas standard density transducers Density of mixtures and pure gases Range PB PFC/de 1 wydanie 3 z dnia 25.09.2023 r.","parameters_zh":[{"name":"范围","range":"(0,717 – 1,250) kg/m3"}],"search_zh":"范围 PB PFC/de 1 wydanie 3 z dnia 25.09.2023 r."},{"_id":"6a5dc9c6f1c10c8ce8260599","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Paliwa gazowe: syntetyczne mieszaniny gazowe","test_object_en":"Gaseous fuels: synthetic gas mixtures","methodology":"Stężenie THT w gazie","methodology_en":"THT concentration in gas","parameters":[{"name":"Zakres","range":"(1,5 - 100) mg/m3"},{"name":"Zakres z przeliczenia","range":"(0,38 – 25,45) ppm"}],"parameters_en":[{"name":"Range","range":"(1,5 - 100) mg/m3"},{"name":"Range from conversion","range":"(0,38 – 25,45) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)"],"technique_en":"Gas chromatography with flame photometric detection (GC-FPD)","computed":[],"computed_en":[],"activity":"Stężenie THT w gazie\nZakres:\nZakres (1,5 - 100) mg/m3\nZakres z przeliczenia (0,38 – 25,45) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)","reference":"PB PFC/THT wydanie 2 z dnia 25.09.2023 r.","norm_bases":["PB PFC/THT wydanie 2 z dnia 25.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: syntetyczne mieszaniny gazowe Stężenie THT w gazie\nZakres:\nZakres (1,5 - 100) mg/m3\nZakres z przeliczenia (0,38 – 25,45) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD) PB PFC/THT wydanie 2 z dnia 25.09.2023 r. Paliwa gazowe: syntetyczne mieszaniny gazowe Stezenie THT w gazie\nZakres:\nZakres (1,5 - 100) mg/m3\nZakres z przeliczenia (0,38 – 25,45) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-fotometryczna (GC-FPD) PB PFC/THT wydanie 2 z dnia 25.09.2023 r.","categories":["petro"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: synthetic gas mixtures THT concentration in gas Gas chromatography with flame photometric detection (GC-FPD) Range Range from conversion PB PFC/THT wydanie 2 z dnia 25.09.2023 r.","parameters_zh":[{"name":"范围","range":"(1,5 - 100) mg/m3"},{"name":"Zakres z przeliczenia","range":"(0,38 – 25,45) ppm"}],"search_zh":"气相色谱-火焰光度检测法（GC-FPD） 范围 PB PFC/THT wydanie 2 z dnia 25.09.2023 r.","technique_zh":"气相色谱-火焰光度检测法（GC-FPD）"},{"_id":"6a5dc9c6f1c10c8ce826059a","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, biogaz (biometan), mieszaniny gazowe","test_object_en":"Gaseous fuels: natural gas, biogas (biomethane), gas mixtures","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB PFC/sa 1 wydanie 6 z dnia 25.09.2023 r.","norm_bases":["PB PFC/sa 1 wydanie 6 z dnia 25.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny, biogaz (biometan), mieszaniny gazowe Pobieranie próbek do badań chemicznych i fizycznych PB PFC/sa 1 wydanie 6 z dnia 25.09.2023 r. Paliwa gazowe: gaz ziemny, biogaz (biometan), mieszaniny gazowe Pobieranie probek do badan chemicznych i fizycznych PB PFC/sa 1 wydanie 6 z dnia 25.09.2023 r.","categories":["petro"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas, biogas (biomethane), gas mixtures Sampling for chemical and physical testing PB PFC/sa 1 wydanie 6 z dnia 25.09.2023 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB PFC/sa 1 wydanie 6 z dnia 25.09.2023 r."},{"_id":"6a5dc9c6f1c10c8ce826059b","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy, Przetworniki ciśnienia, Przetworniki różnicy ciśnień, Czujniki platynowe termometru rezystancyjnego, Przetworniki temperatury","test_object_en":"Gas meter volume conversion devices, Pressure transmitters, Differential pressure transmitters, Platinum resistance thermometer sensors, Temperature transmitters","methodology":"Właściwości metrologiczne i konstrukcyjne (badania w siedzibie laboratorium)","methodology_en":"Metrological and design properties (tests at the laboratory premises)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości metrologiczne i konstrukcyjne (badania w siedzibie laboratorium)","reference":"ZN-G-4007:2001 | PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r.","norm_bases":["ZN-G-4007:2001","PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przeliczniki do gazomierzy, Przetworniki ciśnienia, Przetworniki różnicy ciśnień, Czujniki platynowe termometru rezystancyjnego, Przetworniki temperatury Właściwości metrologiczne i konstrukcyjne (badania w siedzibie laboratorium) ZN-G-4007:2001 | PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r. Przeliczniki do gazomierzy, Przetworniki cisnienia, Przetworniki roznicy cisnien, Czujniki platynowe termometru rezystancyjnego, Przetworniki temperatury Wlasciwosci metrologiczne i konstrukcyjne (badania w siedzibie laboratorium) ZN-G-4007:2001 | PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r.","categories":["metrology"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas meter volume conversion devices, Pressure transmitters, Differential pressure transmitters, Platinum resistance thermometer sensors, Temperature transmitters Metrological and design properties (tests at the laboratory premises) ZN-G-4007:2001 | PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r."},{"_id":"6a5dc9c6f1c10c8ce826059c","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy","test_object_en":"Gas meter volume conversion devices","methodology":"Właściwości metrologiczne i konstrukcyjne (badania w miejscu instalacji)","methodology_en":"Metrological and design properties (tests at the installation site)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości metrologiczne i konstrukcyjne (badania w miejscu instalacji)","reference":"ZN-G-4007:2001 | PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r.","norm_bases":["ZN-G-4007:2001","PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przeliczniki do gazomierzy Właściwości metrologiczne i konstrukcyjne (badania w miejscu instalacji) ZN-G-4007:2001 | PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r. Przeliczniki do gazomierzy Wlasciwosci metrologiczne i konstrukcyjne (badania w miejscu instalacji) ZN-G-4007:2001 | PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r.","categories":["metrology"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas meter volume conversion devices Metrological and design properties (tests at the installation site) ZN-G-4007:2001 | PB PBP/p 2 wydanie 9 z dnia 15.09.2025 r."},{"_id":"6a5dc9c6f1c10c8ce826059d","lab_id":"69ad52a3de79e566650fb195","country":"PL","accr_number":"AB 278","accr_body":"PCA","test_object":"Przeliczniki do gazomierzy E","test_object_en":"Gas volume converters E","methodology":"Właściwości metrologiczne i konstrukcyjne","methodology_en":"Metrological and design properties","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości metrologiczne i konstrukcyjne","reference":"PN-EN 12405-1","norm_bases":["PN-EN 12405-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przeliczniki do gazomierzy E Właściwości metrologiczne i konstrukcyjne PN-EN 12405-1 Przeliczniki do gazomierzy E Wlasciwosci metrologiczne i konstrukcyjne PN-EN 12405-1","categories":["metrology"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas volume converters E Metrological and design properties PN-EN 12405-1"}],"has_pdf":true}