🇵🇱 UNIWERSYTET JANA KOCHANOWSKIEGO W KIELCACH PL
环境水与废水
UNIWERSYTET JANA KOCHANOWSKIEGO W KIELCACH 是由 PCA 认可的实验室,认可编号 AB 1622(Kielce,波兰)。认可范围涵盖 20 项检测方法,涉及以下领域:环境、水与废水。检测对象包括:土壤、Ambient air、Water, treated wastewater、Plastic and rubber products (polymer composites based on thermoplas…。
要点速览
- 认可编号: PCA AB 1622
- 认可范围内方法数: 20
- 检测对象种类: 4
- 城市: Kielce, 波兰
- 认可编号
- AB 1622
- 认可机构
- PCA
- 地址
- ul. Żeromskiego 5, 25-369 Kielce, CENTRUM BADAŃ I ANALIZ, WYDZIAŁ NAUK ŚCISŁYCH I PRZYRODNICZYCH, UNIWERSYTET JANA KOCHANOWSKIEGO W KIELCACH
- 城市
- Kielce, 波兰
该实验室检测什么 (4)
- 土壤 — 9 项方法
- Ambient air — 5 项方法
- Water, treated wastewater — 5 项方法
- Plastic and rubber products (polymer composites based on thermoplastics, chemically and thermally cured resins and elastomers) Construction products, materials and works (products made of wood and wood-like materials, concretes, plastics) — 1 项方法
认可范围 — 项检测方法 (20)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | Water, treated wastewater | Element concentrations: Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Hg, Tl, Pb, Bi, Po, At, Rn, Fr, Ra, Ac, Th, Pa, U Range: (0,010 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF) | PT5.2 wydanie 9 z dnia 19.10.2017 r. | ||
| 2 | Water, treated wastewater | Element concentrations: K, Ca, Y, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au Range: (0,050 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF) | |||
| 3 | Water, treated wastewater | Element concentrations: Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu Range: (0,100 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF) | |||
| 4 | Water, treated wastewater | Element concentrations: P, S, Cl Range: (0,200 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF) | |||
| 5 | Water, treated wastewater | Element concentrations: Pd, Cd, In, I Range: (1,000 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF) | |||
| 6 | 土壤 | Element concentrations: S, Cl, V, Cr, Co, Ni, As, Se, Br, Rb, Y, Nb, Mo, Ag, Cd, Sb, Hg, Tl, Bi Range: (0,01 – 0,1) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) | ISO 18227:2014 | ||
| 7 | 土壤 | Element concentrations: Ba Range: (0,01 – 0,2) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) | |||
| 8 | 土壤 | Element concentrations: P, Mn, Sr Range: (0,01 – 1) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) | |||
| 9 | 土壤 | Element concentrations: Ti Range: (0,01 – 2) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) | |||
| 10 | 土壤 | Element concentrations: Na, Mg, K, Cu, Zn Range: (0,01 – 5) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) | |||
| 11 | 土壤 | Element concentrations: Ca, Fe, Pb Range: (0,01 – 10) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) | |||
| 12 | 土壤 | Element concentrations: Zr Range: (0,01 – 15) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) | |||
| 13 | 土壤 | Element concentrations: Al Range: (0,01 – 20) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) | ISO 18227:2014 | ||
| 14 | 土壤 | Element concentrations: Si Range: (0,01 – 70) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) | |||
| 15 | Ambient air | Ozone (O ) concentration 3 Range: (1 – 800) µg/m3 Ultraviolet photometry method | PN-EN 14625:2013-02 | ||
| 16 | Ambient air | Nitrogen monoxide (NO) concentration Range: (1 – 275) µg/m3 Nitrogen dioxide (NO ) concentration 2 Range: (1 – 420) µg/m3 Nitrogen oxides (NO) concentration x Range: (1 – 420) µg/m3 Chemiluminescence method | PN-EN 14211:2013-02 | ||
| 17 | Ambient air | Sulphur dioxide (SO ) concentration 2 Range: (1 – 660) µg/m3 Ultraviolet fluorescence method | PN-EN 14212:2013-02 PN-EN 14212:2013-02/AC:2014-06 | ||
| 18 | Ambient air | Concentration of suspended particulate matter PM2,5 Range: (1 – 1000) µg/m3 Light scattering method | PN-EN 16450:2017-05 | ||
| 19 | Ambient air | Concentration of suspended particulate matter PM10 Range: (1 – 1000) µg/m3 Light scattering method | |||
| 20 | Plastic and rubber products (polymer composites based on thermoplastics, chemically and thermally cured resins and elastomers) Construction products, materials and works (products made of wood and wood-like materials, concretes, plastics) | Specific optical density of smoke Single-chamber test method (25 kW/m2 without burner, 50 kW/m2 without burner) | PN-EN ISO 5659-2:2017-08 | ||
引用标准 (7)
ISO 18227:2014
PN-EN 14211:2013-02
PN-EN 14212:2013-02 PN-EN 14212:2013-02/AC:2014-06
PN-EN 14625:2013-02
PN-EN 16450:2017-05
PN-EN ISO 5659-2:2017-08
PT5.2 wydanie 9 z dnia 19.10.2017 r.