🇵🇱 UNIWERSYTET JANA KOCHANOWSKIEGO W KIELCACH PL

PCA AB 1622 • Kielce, 波兰 • 20 项方法

环境水与废水

UNIWERSYTET JANA KOCHANOWSKIEGO W KIELCACH 是由 PCA 认可的实验室,认可编号 AB 1622(Kielce,波兰)。认可范围涵盖 20 项检测方法,涉及以下领域:环境、水与废水。检测对象包括:土壤、Ambient air、Water, treated wastewater、Plastic and rubber products (polymer composites based on thermoplas…。

要点速览

  • 认可编号: PCA AB 1622
  • 认可范围内方法数: 20
  • 检测对象种类: 4
  • 城市: Kielce, 波兰
认可编号
AB 1622
认可机构
PCA
地址
ul. Żeromskiego 5, 25-369 Kielce, CENTRUM BADAŃ I ANALIZ, WYDZIAŁ NAUK ŚCISŁYCH I PRZYRODNICZYCH, UNIWERSYTET JANA KOCHANOWSKIEGO W KIELCACH
城市
Kielce, 波兰

该实验室检测什么 (4)

认可范围 — 项检测方法 (20)

序号 检测对象 方法 / 参数 技术 依据文件
检测方法
1 Water, treated wastewater Element concentrations: Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Hg, Tl, Pb, Bi, Po, At, Rn, Fr, Ra, Ac, Th, Pa, U Range: (0,010 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF) PT5.2 wydanie 9 z dnia 19.10.2017 r.
2 Water, treated wastewater Element concentrations: K, Ca, Y, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au Range: (0,050 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)
3 Water, treated wastewater Element concentrations: Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu Range: (0,100 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)
4 Water, treated wastewater Element concentrations: P, S, Cl Range: (0,200 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)
5 Water, treated wastewater Element concentrations: Pd, Cd, In, I Range: (1,000 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)
6 土壤 Element concentrations: S, Cl, V, Cr, Co, Ni, As, Se, Br, Rb, Y, Nb, Mo, Ag, Cd, Sb, Hg, Tl, Bi Range: (0,01 – 0,1) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) ISO 18227:2014
7 土壤 Element concentrations: Ba Range: (0,01 – 0,2) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)
8 土壤 Element concentrations: P, Mn, Sr Range: (0,01 – 1) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)
9 土壤 Element concentrations: Ti Range: (0,01 – 2) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)
10 土壤 Element concentrations: Na, Mg, K, Cu, Zn Range: (0,01 – 5) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)
11 土壤 Element concentrations: Ca, Fe, Pb Range: (0,01 – 10) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)
12 土壤 Element concentrations: Zr Range: (0,01 – 15) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)
13 土壤 Element concentrations: Al Range: (0,01 – 20) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) ISO 18227:2014
14 土壤 Element concentrations: Si Range: (0,01 – 70) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)
15 Ambient air Ozone (O ) concentration 3 Range: (1 – 800) µg/m3 Ultraviolet photometry method PN-EN 14625:2013-02
16 Ambient air Nitrogen monoxide (NO) concentration Range: (1 – 275) µg/m3 Nitrogen dioxide (NO ) concentration 2 Range: (1 – 420) µg/m3 Nitrogen oxides (NO) concentration x Range: (1 – 420) µg/m3 Chemiluminescence method PN-EN 14211:2013-02
17 Ambient air Sulphur dioxide (SO ) concentration 2 Range: (1 – 660) µg/m3 Ultraviolet fluorescence method PN-EN 14212:2013-02 PN-EN 14212:2013-02/AC:2014-06
18 Ambient air Concentration of suspended particulate matter PM2,5 Range: (1 – 1000) µg/m3 Light scattering method PN-EN 16450:2017-05
19 Ambient air Concentration of suspended particulate matter PM10 Range: (1 – 1000) µg/m3 Light scattering method
20 Plastic and rubber products (polymer composites based on thermoplastics, chemically and thermally cured resins and elastomers) Construction products, materials and works (products made of wood and wood-like materials, concretes, plastics) Specific optical density of smoke Single-chamber test method (25 kW/m2 without burner, 50 kW/m2 without burner) PN-EN ISO 5659-2:2017-08

引用标准 (7)

ISO 18227:2014
PN-EN 14211:2013-02
PN-EN 14212:2013-02 PN-EN 14212:2013-02/AC:2014-06
PN-EN 14625:2013-02
PN-EN 16450:2017-05
PN-EN ISO 5659-2:2017-08
PT5.2 wydanie 9 z dnia 19.10.2017 r.