{"lab":{"_id":"69ad52a3de79e566650fb883","accr_number":"AB 1622","country":"PL","accr_body":"PCA","address":"ul. Żeromskiego 5, 25-369 Kielce, CENTRUM BADAŃ I ANALIZ, WYDZIAŁ NAUK ŚCISŁYCH I PRZYRODNICZYCH, UNIWERSYTET JANA KOCHANOWSKIEGO W KIELCACH","categories":["environment","water"],"city":"Kielce","imported_at":"2026-03-08T10:42:43.265Z","methods_count":20,"name":"UNIWERSYTET JANA KOCHANOWSKIEGO W KIELCACH","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1622.pdf"],"scope_summary":"","search_text":"uniwersytet jana kochanowskiego w kielcach ul. żeromskiego 5, 25-369 kielce, centrum badań i analiz, wydział nauk ścisłych i przyrodniczych, uniwersytet jana kochanowskiego w kielcach water other environment materials construction","status":"active","updated_at":"2026-03-08T14:50:45.282Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:45.282Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201622,podmiot.html","parse_date":"2026-07-17T16:19:16.432Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/9/P","pl":"Badania chemiczne i pobieranie próbek powietrza","en":"Chemical tests and sampling of air"},{"codes":"C/28, C/30, C/31","pl":"Badania chemiczne wody, ścieków, gleby","en":"Chemical tests of water, sewage, soil"},{"codes":"N/9","pl":"Badanie właściwości fizycznych powietrza","en":"Tests of physical properties of air"},{"codes":"H/5, H/21","pl":"Badania ogniowe wyrobów, materiałów, obiektów budowlanych, wyrobów z tworzyw sztucznych i gumy","en":"Fire tests of building products, building materials, building items, plastic and rubber products"}],"issue":{"no":"10","date":"02.09.2024"},"map_coord":[50.866646,20.637362],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":14,"water":5,"materials":1,"construction":1},"category_scores":{"environment":9.33,"water":1.19,"materials":0.05,"construction":0.05},"has_zh":true},"methods":[{"_id":"6a5a56049af9f73f382547b1","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Woda, ścieki oczyszczone","test_object_en":"Water, treated wastewater","methodology":"Stężenie pierwiastków: Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Hg, Tl, Pb, Bi, Po, At, Rn, Fr, Ra, Ac, Th, Pa, U Zakres: (0,010 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF)","methodology_en":"Element concentrations: Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Hg, Tl, Pb, Bi, Po, At, Rn, Fr, Ra, Ac, Th, Pa, U Range: (0,010 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Hg, Tl, Pb, Bi, Po, At, Rn, Fr, Ra, Ac, Th, Pa, U Zakres: (0,010 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF)","reference":"PT5.2 wydanie 9 z dnia 19.10.2017 r.","norm_bases":["PT5.2 wydanie 9 z dnia 19.10.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki oczyszczone Stężenie pierwiastków: Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Hg, Tl, Pb, Bi, Po, At, Rn, Fr, Ra, Ac, Th, Pa, U Zakres: (0,010 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF) PT5.2 wydanie 9 z dnia 19.10.2017 r. Woda, scieki oczyszczone Stezenie pierwiastkow: Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Hg, Tl, Pb, Bi, Po, At, Rn, Fr, Ra, Ac, Th, Pa, U Zakres: (0,010 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z calkowitym odbiciem wiazki padajacej (TXRF) PT5.2 wydanie 9 z dnia 19.10.2017 r.","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, treated wastewater Element concentrations: Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Hg, Tl, Pb, Bi, Po, At, Rn, Fr, Ra, Ac, Th, Pa, U Range: (0,010 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF) PT5.2 wydanie 9 z dnia 19.10.2017 r.","search_zh":"水、处理后废水 PT5.2 wydanie 9 z dnia 19.10.2017 r.","test_object_zh":"水、处理后废水"},{"_id":"6a5a56049af9f73f382547b2","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Woda, ścieki oczyszczone","test_object_en":"Water, treated wastewater","methodology":"Stężenie pierwiastków: K, Ca, Y, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au Zakres: (0,050 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF)","methodology_en":"Element concentrations: K, Ca, Y, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au Range: (0,050 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: K, Ca, Y, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au Zakres: (0,050 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki oczyszczone Stężenie pierwiastków: K, Ca, Y, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au Zakres: (0,050 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF) Woda, scieki oczyszczone Stezenie pierwiastkow: K, Ca, Y, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au Zakres: (0,050 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z calkowitym odbiciem wiazki padajacej (TXRF)","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, treated wastewater Element concentrations: K, Ca, Y, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au Range: (0,050 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)","search_zh":"水、处理后废水","test_object_zh":"水、处理后废水"},{"_id":"6a5a56049af9f73f382547b3","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Woda, ścieki oczyszczone","test_object_en":"Water, treated wastewater","methodology":"Stężenie pierwiastków: Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu Zakres: (0,100 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF)","methodology_en":"Element concentrations: Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu Range: (0,100 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu Zakres: (0,100 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki oczyszczone Stężenie pierwiastków: Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu Zakres: (0,100 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF) Woda, scieki oczyszczone Stezenie pierwiastkow: Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu Zakres: (0,100 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z calkowitym odbiciem wiazki padajacej (TXRF)","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, treated wastewater Element concentrations: Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu Range: (0,100 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)","search_zh":"水、处理后废水","test_object_zh":"水、处理后废水"},{"_id":"6a5a56049af9f73f382547b4","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Woda, ścieki oczyszczone","test_object_en":"Water, treated wastewater","methodology":"Stężenie pierwiastków: P, S, Cl Zakres: (0,200 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF)","methodology_en":"Element concentrations: P, S, Cl Range: (0,200 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: P, S, Cl Zakres: (0,200 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki oczyszczone Stężenie pierwiastków: P, S, Cl Zakres: (0,200 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF) Woda, scieki oczyszczone Stezenie pierwiastkow: P, S, Cl Zakres: (0,200 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z calkowitym odbiciem wiazki padajacej (TXRF)","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, treated wastewater Element concentrations: P, S, Cl Range: (0,200 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)","search_zh":"水、处理后废水","test_object_zh":"水、处理后废水"},{"_id":"6a5a56049af9f73f382547b5","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Woda, ścieki oczyszczone","test_object_en":"Water, treated wastewater","methodology":"Stężenie pierwiastków: Pd, Cd, In, I Zakres: (1,000 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF)","methodology_en":"Element concentrations: Pd, Cd, In, I Range: (1,000 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: Pd, Cd, In, I Zakres: (1,000 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki oczyszczone Stężenie pierwiastków: Pd, Cd, In, I Zakres: (1,000 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z całkowitym odbiciem wiązki padającej (TXRF) Woda, scieki oczyszczone Stezenie pierwiastkow: Pd, Cd, In, I Zakres: (1,000 – 1000) mg/l Metoda fluorescencyjnej spektrometrii rentgenowskiej z calkowitym odbiciem wiazki padajacej (TXRF)","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, treated wastewater Element concentrations: Pd, Cd, In, I Range: (1,000 – 1000) mg/l Total reflection X-ray fluorescence spectrometry method (TXRF)","search_zh":"水、处理后废水","test_object_zh":"水、处理后废水"},{"_id":"6a5a56049af9f73f382547b6","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie pierwiastków: S, Cl, V, Cr, Co, Ni, As, Se, Br, Rb, Y, Nb, Mo, Ag, Cd, Sb, Hg, Tl, Bi Zakres: (0,01 – 0,1) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","methodology_en":"Element concentrations: S, Cl, V, Cr, Co, Ni, As, Se, Br, Rb, Y, Nb, Mo, Ag, Cd, Sb, Hg, Tl, Bi Range: (0,01 – 0,1) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: S, Cl, V, Cr, Co, Ni, As, Se, Br, Rb, Y, Nb, Mo, Ag, Cd, Sb, Hg, Tl, Bi Zakres: (0,01 – 0,1) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"ISO 18227:2014","norm_bases":["ISO 18227:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie pierwiastków: S, Cl, V, Cr, Co, Ni, As, Se, Br, Rb, Y, Nb, Mo, Ag, Cd, Sb, Hg, Tl, Bi Zakres: (0,01 – 0,1) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) ISO 18227:2014 Gleba Stezenie pierwiastkow: S, Cl, V, Cr, Co, Ni, As, Se, Br, Rb, Y, Nb, Mo, Ag, Cd, Sb, Hg, Tl, Bi Zakres: (0,01 – 0,1) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) ISO 18227:2014","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Element concentrations: S, Cl, V, Cr, Co, Ni, As, Se, Br, Rb, Y, Nb, Mo, Ag, Cd, Sb, Hg, Tl, Bi Range: (0,01 – 0,1) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) ISO 18227:2014","search_zh":"土壤 ISO 18227:2014","test_object_zh":"土壤"},{"_id":"6a5a56049af9f73f382547b7","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie pierwiastków: Ba Zakres: (0,01 – 0,2) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","methodology_en":"Element concentrations: Ba Range: (0,01 – 0,2) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: Ba Zakres: (0,01 – 0,2) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie pierwiastków: Ba Zakres: (0,01 – 0,2) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Gleba Stezenie pierwiastkow: Ba Zakres: (0,01 – 0,2) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF)","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Element concentrations: Ba Range: (0,01 – 0,2) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","search_zh":"土壤","test_object_zh":"土壤"},{"_id":"6a5a56049af9f73f382547b8","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie pierwiastków: P, Mn, Sr Zakres: (0,01 – 1) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","methodology_en":"Element concentrations: P, Mn, Sr Range: (0,01 – 1) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: P, Mn, Sr Zakres: (0,01 – 1) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie pierwiastków: P, Mn, Sr Zakres: (0,01 – 1) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Gleba Stezenie pierwiastkow: P, Mn, Sr Zakres: (0,01 – 1) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF)","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Element concentrations: P, Mn, Sr Range: (0,01 – 1) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","search_zh":"土壤","test_object_zh":"土壤"},{"_id":"6a5a56049af9f73f382547b9","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie pierwiastków: Ti Zakres: (0,01 – 2) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","methodology_en":"Element concentrations: Ti Range: (0,01 – 2) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: Ti Zakres: (0,01 – 2) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie pierwiastków: Ti Zakres: (0,01 – 2) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Gleba Stezenie pierwiastkow: Ti Zakres: (0,01 – 2) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF)","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Element concentrations: Ti Range: (0,01 – 2) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","search_zh":"土壤","test_object_zh":"土壤"},{"_id":"6a5a56049af9f73f382547ba","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie pierwiastków: Na, Mg, K, Cu, Zn Zakres: (0,01 – 5) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","methodology_en":"Element concentrations: Na, Mg, K, Cu, Zn Range: (0,01 – 5) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: Na, Mg, K, Cu, Zn Zakres: (0,01 – 5) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie pierwiastków: Na, Mg, K, Cu, Zn Zakres: (0,01 – 5) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Gleba Stezenie pierwiastkow: Na, Mg, K, Cu, Zn Zakres: (0,01 – 5) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF)","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Element concentrations: Na, Mg, K, Cu, Zn Range: (0,01 – 5) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","search_zh":"土壤","test_object_zh":"土壤"},{"_id":"6a5a56049af9f73f382547bb","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie pierwiastków: Ca, Fe, Pb Zakres: (0,01 – 10) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","methodology_en":"Element concentrations: Ca, Fe, Pb Range: (0,01 – 10) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: Ca, Fe, Pb Zakres: (0,01 – 10) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie pierwiastków: Ca, Fe, Pb Zakres: (0,01 – 10) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Gleba Stezenie pierwiastkow: Ca, Fe, Pb Zakres: (0,01 – 10) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF)","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Element concentrations: Ca, Fe, Pb Range: (0,01 – 10) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","search_zh":"土壤","test_object_zh":"土壤"},{"_id":"6a5a56049af9f73f382547bc","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie pierwiastków: Zr Zakres: (0,01 – 15) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","methodology_en":"Element concentrations: Zr Range: (0,01 – 15) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: Zr Zakres: (0,01 – 15) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie pierwiastków: Zr Zakres: (0,01 – 15) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Gleba Stezenie pierwiastkow: Zr Zakres: (0,01 – 15) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF)","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Element concentrations: Zr Range: (0,01 – 15) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","search_zh":"土壤","test_object_zh":"土壤"},{"_id":"6a5a56049af9f73f382547bd","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie pierwiastków: Al Zakres: (0,01 – 20) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","methodology_en":"Element concentrations: Al Range: (0,01 – 20) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: Al Zakres: (0,01 – 20) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"ISO 18227:2014","norm_bases":["ISO 18227:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie pierwiastków: Al Zakres: (0,01 – 20) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) ISO 18227:2014 Gleba Stezenie pierwiastkow: Al Zakres: (0,01 – 20) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) ISO 18227:2014","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Element concentrations: Al Range: (0,01 – 20) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) ISO 18227:2014","search_zh":"土壤 ISO 18227:2014","test_object_zh":"土壤"},{"_id":"6a5a56049af9f73f382547be","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie pierwiastków: Si Zakres: (0,01 – 70) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","methodology_en":"Element concentrations: Si Range: (0,01 – 70) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków: Si Zakres: (0,01 – 70) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie pierwiastków: Si Zakres: (0,01 – 70) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Gleba Stezenie pierwiastkow: Si Zakres: (0,01 – 70) % Metoda fluoroscencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF)","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Element concentrations: Si Range: (0,01 – 70) % Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","search_zh":"土壤","test_object_zh":"土壤"},{"_id":"6a5a56049af9f73f382547bf","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Powietrze atmosferyczne","test_object_en":"Ambient air","methodology":"Stężenie ozonu (O ) 3 Zakres: (1 – 800) µg/m3 Metoda fotometrii w nadfiolecie","methodology_en":"Ozone (O ) concentration 3 Range: (1 – 800) µg/m3 Ultraviolet photometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ozonu (O ) 3 Zakres: (1 – 800) µg/m3 Metoda fotometrii w nadfiolecie","reference":"PN-EN 14625:2013-02","norm_bases":["PN-EN 14625:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze atmosferyczne Stężenie ozonu (O ) 3 Zakres: (1 – 800) µg/m3 Metoda fotometrii w nadfiolecie PN-EN 14625:2013-02 Powietrze atmosferyczne Stezenie ozonu (O ) 3 Zakres: (1 – 800) µg/m3 Metoda fotometrii w nadfiolecie PN-EN 14625:2013-02","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ambient air Ozone (O ) concentration 3 Range: (1 – 800) µg/m3 Ultraviolet photometry method PN-EN 14625:2013-02","search_zh":"大气空气 PN-EN 14625:2013-02","test_object_zh":"大气空气"},{"_id":"6a5a56049af9f73f382547c0","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Powietrze atmosferyczne","test_object_en":"Ambient air","methodology":"Stężenie tlenku azotu (NO) Zakres: (1 – 275) µg/m3 Stężenie ditlenku azotu (NO ) 2 Zakres: (1 – 420) µg/m3 Stężenie tlenków azotu (NO) x Zakres: (1 – 420) µg/m3 Metoda chemiluminescencyjna","methodology_en":"Nitrogen monoxide (NO) concentration Range: (1 – 275) µg/m3 Nitrogen dioxide (NO ) concentration 2 Range: (1 – 420) µg/m3 Nitrogen oxides (NO) concentration x Range: (1 – 420) µg/m3 Chemiluminescence method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu (NO) Zakres: (1 – 275) µg/m3 Stężenie ditlenku azotu (NO ) 2 Zakres: (1 – 420) µg/m3 Stężenie tlenków azotu (NO) x Zakres: (1 – 420) µg/m3 Metoda chemiluminescencyjna","reference":"PN-EN 14211:2013-02","norm_bases":["PN-EN 14211:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze atmosferyczne Stężenie tlenku azotu (NO) Zakres: (1 – 275) µg/m3 Stężenie ditlenku azotu (NO ) 2 Zakres: (1 – 420) µg/m3 Stężenie tlenków azotu (NO) x Zakres: (1 – 420) µg/m3 Metoda chemiluminescencyjna PN-EN 14211:2013-02 Powietrze atmosferyczne Stezenie tlenku azotu (NO) Zakres: (1 – 275) µg/m3 Stezenie ditlenku azotu (NO ) 2 Zakres: (1 – 420) µg/m3 Stezenie tlenkow azotu (NO) x Zakres: (1 – 420) µg/m3 Metoda chemiluminescencyjna PN-EN 14211:2013-02","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ambient air Nitrogen monoxide (NO) concentration Range: (1 – 275) µg/m3 Nitrogen dioxide (NO ) concentration 2 Range: (1 – 420) µg/m3 Nitrogen oxides (NO) concentration x Range: (1 – 420) µg/m3 Chemiluminescence method PN-EN 14211:2013-02","search_zh":"大气空气 PN-EN 14211:2013-02","test_object_zh":"大气空气"},{"_id":"6a5a56049af9f73f382547c1","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Powietrze atmosferyczne","test_object_en":"Ambient air","methodology":"Stężenie ditlenku siarki (SO ) 2 Zakres: (1 – 660) µg/m3 Metoda fluorescencji w nadfiolecie","methodology_en":"Sulphur dioxide (SO ) concentration 2 Range: (1 – 660) µg/m3 Ultraviolet fluorescence method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ditlenku siarki (SO ) 2 Zakres: (1 – 660) µg/m3 Metoda fluorescencji w nadfiolecie","reference":"PN-EN 14212:2013-02 PN-EN 14212:2013-02/AC:2014-06","norm_bases":["PN-EN 14212:2013-02 PN-EN 14212:2013-02/AC:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze atmosferyczne Stężenie ditlenku siarki (SO ) 2 Zakres: (1 – 660) µg/m3 Metoda fluorescencji w nadfiolecie PN-EN 14212:2013-02 PN-EN 14212:2013-02/AC:2014-06 Powietrze atmosferyczne Stezenie ditlenku siarki (SO ) 2 Zakres: (1 – 660) µg/m3 Metoda fluorescencji w nadfiolecie PN-EN 14212:2013-02 PN-EN 14212:2013-02/AC:2014-06","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ambient air Sulphur dioxide (SO ) concentration 2 Range: (1 – 660) µg/m3 Ultraviolet fluorescence method PN-EN 14212:2013-02 PN-EN 14212:2013-02/AC:2014-06","search_zh":"大气空气 PN-EN 14212:2013-02 PN-EN 14212:2013-02/AC:2014-06","test_object_zh":"大气空气"},{"_id":"6a5a56049af9f73f382547c2","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Powietrze atmosferyczne","test_object_en":"Ambient air","methodology":"Stężenie pyłu zawieszonego PM2,5 Zakres: (1 – 1000) µg/m3 Metoda rozpraszania światła","methodology_en":"Concentration of suspended particulate matter PM2,5 Range: (1 – 1000) µg/m3 Light scattering method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu zawieszonego PM2,5 Zakres: (1 – 1000) µg/m3 Metoda rozpraszania światła","reference":"PN-EN 16450:2017-05","norm_bases":["PN-EN 16450:2017-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze atmosferyczne Stężenie pyłu zawieszonego PM2,5 Zakres: (1 – 1000) µg/m3 Metoda rozpraszania światła PN-EN 16450:2017-05 Powietrze atmosferyczne Stezenie pylu zawieszonego PM2,5 Zakres: (1 – 1000) µg/m3 Metoda rozpraszania swiatla PN-EN 16450:2017-05","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ambient air Concentration of suspended particulate matter PM2,5 Range: (1 – 1000) µg/m3 Light scattering method PN-EN 16450:2017-05","search_zh":"大气空气 PN-EN 16450:2017-05","test_object_zh":"大气空气"},{"_id":"6a5a56049af9f73f382547c3","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Powietrze atmosferyczne","test_object_en":"Ambient air","methodology":"Stężenie pyłu zawieszonego PM10 Zakres: (1 – 1000) µg/m3 Metoda rozpraszania światła","methodology_en":"Concentration of suspended particulate matter PM10 Range: (1 – 1000) µg/m3 Light scattering method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu zawieszonego PM10 Zakres: (1 – 1000) µg/m3 Metoda rozpraszania światła","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze atmosferyczne Stężenie pyłu zawieszonego PM10 Zakres: (1 – 1000) µg/m3 Metoda rozpraszania światła Powietrze atmosferyczne Stezenie pylu zawieszonego PM10 Zakres: (1 – 1000) µg/m3 Metoda rozpraszania swiatla","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Ambient air Concentration of suspended particulate matter PM10 Range: (1 – 1000) µg/m3 Light scattering method","search_zh":"大气空气","test_object_zh":"大气空气"},{"_id":"6a5a56049af9f73f382547c4","lab_id":"69ad52a3de79e566650fb883","country":"PL","accr_number":"AB 1622","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych i gumy (kompozyty polimerowe na bazie tworzyw termoplastycznych, żywic chemo- i termo- utwardzalnych oraz elastomerów) Wyroby, materiały i obiekty budowlane (wyroby wykonane z materiałów drewnianych i drewnopodobnych, betonów, tworzyw sztucznych)","test_object_en":"Plastic and rubber products (polymer composites based on thermoplastics, chemically and thermally cured resins and elastomers) Construction products, materials and works (products made of wood and wood-like materials, concretes, plastics)","methodology":"Właściwa gęstość optyczna dymu Metoda testu jednokomorowego (25 kW/m2 bez palnika, 50 kW/m2 bez palnika)","methodology_en":"Specific optical density of smoke Single-chamber test method (25 kW/m2 without burner, 50 kW/m2 without burner)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwa gęstość optyczna dymu Metoda testu jednokomorowego (25 kW/m2 bez palnika, 50 kW/m2 bez palnika)","reference":"PN-EN ISO 5659-2:2017-08","norm_bases":["PN-EN ISO 5659-2:2017-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z tworzyw sztucznych i gumy (kompozyty polimerowe na bazie tworzyw termoplastycznych, żywic chemo- i termo- utwardzalnych oraz elastomerów) Wyroby, materiały i obiekty budowlane (wyroby wykonane z materiałów drewnianych i drewnopodobnych, betonów, tworzyw sztucznych) Właściwa gęstość optyczna dymu Metoda testu jednokomorowego (25 kW/m2 bez palnika, 50 kW/m2 bez palnika) PN-EN ISO 5659-2:2017-08 Wyroby z tworzyw sztucznych i gumy (kompozyty polimerowe na bazie tworzyw termoplastycznych, zywic chemo- i termo- utwardzalnych oraz elastomerow) Wyroby, materialy i obiekty budowlane (wyroby wykonane z materialow drewnianych i drewnopodobnych, betonow, tworzyw sztucznych) Wlasciwa gestosc optyczna dymu Metoda testu jednokomorowego (25 kW/m2 bez palnika, 50 kW/m2 bez palnika) PN-EN ISO 5659-2:2017-08","categories":["materials","construction"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plastic and rubber products (polymer composites based on thermoplastics, chemically and thermally cured resins and elastomers) Construction products, materials and works (products made of wood and wood-like materials, concretes, plastics) Specific optical density of smoke Single-chamber test method (25 kW/m2 without burner, 50 kW/m2 without burner) PN-EN ISO 5659-2:2017-08"}],"has_pdf":true}