🇵🇱 PRZEDSIĘBIORSTWO USŁUGOWO-PRODUKCYJNE PL
环境
PRZEDSIĘBIORSTWO USŁUGOWO-PRODUKCYJNE 是由 PCA 认可的实验室,认可编号 AB 1134(Toruń,波兰)。认可范围涵盖 25 项检测方法,涉及以下领域:环境。检测对象包括:废气、General environment – ambient air。
要点速览
- 认可编号: PCA AB 1134
- 认可范围内方法数: 25
- 检测对象种类: 2
- 城市: Toruń, 波兰
- 认可编号
- AB 1134
- 认可机构
- PCA
- 地址
- „EKO-TOR” S.C., Michał Kopczyński, Mirosława Stawska, ul. Grunwaldzka 11/1, 87-100 Toruń
- 城市
- Toruń, 波兰
该实验室检测什么 (2)
- 废气 — 23 项方法
- General environment – ambient air — 2 项方法
认可范围 — 项检测方法 (25)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | 废气 | Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method Velocity (0,4 − 40) m/s Anemometric method | PN-Z-04030-7:1994 | ||
| 2 | 废气 | 粉尘浓度测定采样 | |||
| 3 | 废气 | Dust concentration Range: (0,001 – 18,7) g/m3 Gravimetric method | |||
| 4 | 废气 | 粉尘排放量(计算值) | |||
| 5 | 废气 | Sulphur dioxide concentration Range: SO (6,0 − 2580) mg/m3 2 Non-dispersive infrared spectrometry method (NDIR) | PN-ISO 10396:2001 | ||
| 6 | 废气 | SO 2 emission (calculated) | |||
| 7 | 废气 | Nitrogen monoxide concentration Range: NO (3,0 − 1229) mg/m3 Non-dispersive infrared spectrometry method (NDIR) | PN-ISO 10396:2001 | ||
| 8 | 废气 | NO emission (calculated) | |||
| 9 | 废气 | Nitrogen oxides concentration Range: NO (2,0 − 1883) mg/m3 X Chemiluminescence method | PN-ISO 10396:2001 | ||
| 10 | 废气 | Emission of NO (NO and NO calculated X 2 as NO ) 2 (calculated) | |||
| 11 | 废气 | Carbon monoxide concentration Range: CO (3,0 − 1141) mg/m3 Non-dispersive infrared spectrometry method (NDIR) | PN-ISO 10396:2001 | ||
| 12 | 废气 | Carbon monoxide emission (calculated) | |||
| 13 | 废气 | Oxygen concentration Range: O (0,2 – 21) % 2 Paramagnetic method | PN-ISO 10396:2001 | ||
| 14 | 废气 | Oxygen concentration Range: (0,2 − 21) % Electrochemical method | PN-ISO 10396:2001 | ||
| 15 | 废气 | Carbon dioxide concentration Range: CO (0,1 – 18,1) % 2 Non-dispersive infrared spectrometry method (NDIR) | PN-ISO 10396:2001 | ||
| 16 | 废气 | Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range: (1,0 − 500) mg/m3 Continuous flame ionisation detection method (FID) | PN-EN 12619:2013-05 | ||
| 17 | 废气 | 以总气态有机碳表示的气态与蒸气态有机物排放量(计算值) | |||
| 18 | 废气 | Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon/ silica gel/ absorbing solutions | PN-Z-04008-4:1999 | ||
| 19 | 废气 | 有机化合物排放量(计算值) | |||
| 20 | 废气 | Sampling for determination of the concentration of individual gaseous organic compounds | PN-EN 13649:2005 | ||
| 21 | 废气 | 单项气态有机化合物排放量(计算值) | |||
| 22 | 废气 | Sampling for determination of the concentrations of inorganic and organic compounds Aspiration method | PB-06 wydanie 13 z dnia 17.10.2022 r. | ||
| 23 | 废气 | Emission of inorganic and organic compounds (calculated) | |||
| 24 | General environment – ambient air | Dust concentration Range: (0,01 − 10) mg/m3 Filtration-gravimetric method | PB-08 wydanie 10 z dnia 17.10.2022 r. | ||
| 25 | General environment – ambient air | Sampling for measurement of the concentration of: - dust - organic substances - inorganic substances - metals and their compounds Aspiration method | |||
引用标准 (7)
PB-06 wydanie 13 z dnia 17.10.2022 r.
PB-08 wydanie 10 z dnia 17.10.2022 r.
PN-EN 12619:2013-05
PN-EN 13649:2005
PN-ISO 10396:2001
PN-Z-04008-4:1999
PN-Z-04030-7:1994