{"lab":{"_id":"69ad52a3de79e566650fb5ca","accr_number":"AB 1134","country":"PL","accr_body":"PCA","address":"„EKO-TOR” S.C., Michał Kopczyński, Mirosława Stawska, ul. Grunwaldzka 11/1, 87-100 Toruń","categories":["environment"],"city":"Toruń","imported_at":"2026-03-08T10:42:43.265Z","methods_count":25,"name":"PRZEDSIĘBIORSTWO USŁUGOWO-PRODUKCYJNE","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1134.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo usługowo-produkcyjne „eko-tor” s.c., michał kopczyński, mirosława stawska, ul. grunwaldzka 11/1, 87-100 toruń environment metrology other","status":"active","updated_at":"2026-03-08T14:50:18.645Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:18.645Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201134,podmiot.html","parse_date":"2026-07-17T16:18:53.169Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) - gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) - waste gases"},{"codes":"N/9/P, N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek powietrza, gazów odlotowych","en":"Tests of physical properties and sampling of air, waste gases"},{"codes":"P/9, P/36","pl":"Pobieranie próbek gazów odlotowych, powietrza","en":"Sampling of waste gases, air"}],"issue":{"no":"20","date":"17.12.2025"},"map_coord":[53.02354,18.591524],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":14,"environment":11,"materials":1},"category_scores":{"other":7.54,"environment":4.65,"materials":0.04},"has_zh":true},"methods":[{"_id":"6a5a55ed9af9f73f382502ad","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazów dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia Prędkość (0,4 − 40) m/s Metoda anemometryczna","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method Velocity (0,4 − 40) m/s Anemometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień objętości gazów dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia Prędkość (0,4 − 40) m/s Metoda anemometryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazów dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia Prędkość (0,4 − 40) m/s Metoda anemometryczna PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazow dla cisnien dynamicznych > 10 Pa Metoda spietrzenia Predkosc (0,4 − 40) m/s Metoda anemometryczna PN-Z-04030-7:1994","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method Velocity (0,4 − 40) m/s Anemometric method PN-Z-04030-7:1994","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502ae","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration","search_zh":"废气 粉尘浓度测定采样","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55ed9af9f73f382502af","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,001 – 18,7) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,001 – 18,7) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,001 – 18,7) g/m3 Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,001 – 18,7) g/m3 Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,001 – 18,7) g/m3 Metoda grawimetryczna","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,001 – 18,7) g/m3 Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502b0","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) Gazy odlotowe Emisja pylu (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated)","search_zh":"废气 粉尘排放量（计算值）","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5a55ed9af9f73f382502b1","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku siarki Zakres: SO (6,0 − 2580) mg/m3 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","methodology_en":"Sulphur dioxide concentration Range: SO (6,0 − 2580) mg/m3 2 Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku siarki Zakres: SO (6,0 − 2580) mg/m3 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki Zakres: SO (6,0 − 2580) mg/m3 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku siarki Zakres: SO (6,0 − 2580) mg/m3 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sulphur dioxide concentration Range: SO (6,0 − 2580) mg/m3 2 Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502b2","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO 2 (z obliczeń)","methodology_en":"SO 2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO 2 (z obliczeń) Gazy odlotowe Emisja SO 2 (z obliczen)","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases SO 2 emission (calculated)","search_zh":"废气 SO2 排放（由计算得出）","test_object_zh":"废气","methodology_zh":"SO2 排放（由计算得出）"},{"_id":"6a5a55ed9af9f73f382502b3","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku azotu Zakres: NO (3,0 − 1229) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","methodology_en":"Nitrogen monoxide concentration Range: NO (3,0 − 1229) mg/m3 Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu Zakres: NO (3,0 − 1229) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku azotu Zakres: NO (3,0 − 1229) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenku azotu Zakres: NO (3,0 − 1229) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Nitrogen monoxide concentration Range: NO (3,0 − 1229) mg/m3 Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502b4","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO (z obliczeń)","methodology_en":"NO emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO (z obliczeń) Gazy odlotowe Emisja NO (z obliczen)","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases NO emission (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502b5","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenków azotu Zakres: NO (2,0 − 1883) mg/m3 X Metoda chemiluminescencyjna","methodology_en":"Nitrogen oxides concentration Range: NO (2,0 − 1883) mg/m3 X Chemiluminescence method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenków azotu Zakres: NO (2,0 − 1883) mg/m3 X Metoda chemiluminescencyjna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenków azotu Zakres: NO (2,0 − 1883) mg/m3 X Metoda chemiluminescencyjna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenkow azotu Zakres: NO (2,0 − 1883) mg/m3 X Metoda chemiluminescencyjna PN-ISO 10396:2001","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Nitrogen oxides concentration Range: NO (2,0 − 1883) mg/m3 X Chemiluminescence method PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502b6","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO (NO i NO w przeliczeniu X 2 na NO ) 2 (z obliczeń)","methodology_en":"Emission of NO (NO and NO calculated X 2 as NO ) 2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO (NO i NO w przeliczeniu X 2 na NO ) 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO (NO i NO w przeliczeniu X 2 na NO ) 2 (z obliczeń) Gazy odlotowe Emisja NO (NO i NO w przeliczeniu X 2 na NO ) 2 (z obliczen)","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of NO (NO and NO calculated X 2 as NO ) 2 (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502b7","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla Zakres: CO (3,0 − 1141) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","methodology_en":"Carbon monoxide concentration Range: CO (3,0 − 1141) mg/m3 Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla Zakres: CO (3,0 − 1141) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla Zakres: CO (3,0 − 1141) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenku wegla Zakres: CO (3,0 − 1141) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon monoxide concentration Range: CO (3,0 − 1141) mg/m3 Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502b8","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja tlenku węgla (z obliczeń)","methodology_en":"Carbon monoxide emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja tlenku węgla (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja tlenku węgla (z obliczeń) Gazy odlotowe Emisja tlenku wegla (z obliczen)","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon monoxide emission (calculated)","search_zh":"废气 一氧化碳排放（由计算得出）","test_object_zh":"废气","methodology_zh":"一氧化碳排放（由计算得出）"},{"_id":"6a5a55ed9af9f73f382502b9","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu Zakres: O (0,2 – 21) % 2 Metoda paramagnetyczna","methodology_en":"Oxygen concentration Range: O (0,2 – 21) % 2 Paramagnetic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu Zakres: O (0,2 – 21) % 2 Metoda paramagnetyczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu Zakres: O (0,2 – 21) % 2 Metoda paramagnetyczna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu Zakres: O (0,2 – 21) % 2 Metoda paramagnetyczna PN-ISO 10396:2001","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Oxygen concentration Range: O (0,2 – 21) % 2 Paramagnetic method PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502ba","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu Zakres: (0,2 − 21) % Metoda elektrochemiczna","methodology_en":"Oxygen concentration Range: (0,2 − 21) % Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu Zakres: (0,2 − 21) % Metoda elektrochemiczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu Zakres: (0,2 − 21) % Metoda elektrochemiczna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu Zakres: (0,2 − 21) % Metoda elektrochemiczna PN-ISO 10396:2001","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Oxygen concentration Range: (0,2 − 21) % Electrochemical method PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502bb","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku węgla Zakres: CO (0,1 – 18,1) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","methodology_en":"Carbon dioxide concentration Range: CO (0,1 – 18,1) % 2 Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku węgla Zakres: CO (0,1 – 18,1) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla Zakres: CO (0,1 – 18,1) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku wegla Zakres: CO (0,1 – 18,1) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon dioxide concentration Range: CO (0,1 – 18,1) % 2 Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502bc","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny Zakres: (1,0 − 500) mg/m3 Metoda ciągłej detekcji płomieniowo- jonizacyjnej (FID)","methodology_en":"Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range: (1,0 − 500) mg/m3 Continuous flame ionisation detection method (FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny Zakres: (1,0 − 500) mg/m3 Metoda ciągłej detekcji płomieniowo- jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny Zakres: (1,0 − 500) mg/m3 Metoda ciągłej detekcji płomieniowo- jonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny Zakres: (1,0 − 500) mg/m3 Metoda ciaglej detekcji plomieniowo- jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range: (1,0 − 500) mg/m3 Continuous flame ionisation detection method (FID) PN-EN 12619:2013-05","search_zh":"废气 PN-EN 12619:2013-05","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502bd","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen)","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a5a55ed9af9f73f382502be","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/ roztworów pochłaniających","methodology_en":"Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon/ silica gel/ absorbing solutions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/ roztworów pochłaniających","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego/ żelu krzemionkowego/ roztworów pochłaniających PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych Metoda aspiracyjna z zastosowaniem wegla aktywnego/ zelu krzemionkowego/ roztworow pochlaniajacych PN-Z-04008-4:1999","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon/ silica gel/ absorbing solutions PN-Z-04008-4:1999","search_zh":"废气 PN-Z-04008-4:1999","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502bf","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków organicznych (z obliczeń)","methodology_en":"Emission of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) Gazy odlotowe Emisja zwiazkow organicznych (z obliczen)","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of organic compounds (calculated)","search_zh":"废气 有机化合物排放量（计算值）","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a5a55ed9af9f73f382502c0","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005","search_zh":"废气 单项气态有机化合物浓度测定采样 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a5a55ed9af9f73f382502c1","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","methodology_en":"Emission of individual gaseous organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen)","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated)","search_zh":"废气 单项气态有机化合物排放量（计算值）","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a5a55ed9af9f73f382502c2","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń związków nieorganicznych i organicznych Metoda aspiracyjna","methodology_en":"Sampling for determination of the concentrations of inorganic and organic compounds Aspiration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków nieorganicznych i organicznych Metoda aspiracyjna","reference":"PB-06 wydanie 13 z dnia 17.10.2022 r.","norm_bases":["PB-06 wydanie 13 z dnia 17.10.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków nieorganicznych i organicznych Metoda aspiracyjna PB-06 wydanie 13 z dnia 17.10.2022 r. Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow nieorganicznych i organicznych Metoda aspiracyjna PB-06 wydanie 13 z dnia 17.10.2022 r.","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentrations of inorganic and organic compounds Aspiration method PB-06 wydanie 13 z dnia 17.10.2022 r.","search_zh":"废气 PB-06 wydanie 13 z dnia 17.10.2022 r.","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502c3","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków nieorganicznych i organicznych (z obliczeń)","methodology_en":"Emission of inorganic and organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków nieorganicznych i organicznych (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków nieorganicznych i organicznych (z obliczeń) Gazy odlotowe Emisja zwiazkow nieorganicznych i organicznych (z obliczen)","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of inorganic and organic compounds (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55ed9af9f73f382502c4","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Środowisko ogólne – powietrze atmosferyczne","test_object_en":"General environment – ambient air","methodology":"Stężenie pyłu Zakres: (0,01 − 10) mg/m3 Metoda filtracyjno-wagowa","methodology_en":"Dust concentration Range: (0,01 − 10) mg/m3 Filtration-gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,01 − 10) mg/m3 Metoda filtracyjno-wagowa","reference":"PB-08 wydanie 10 z dnia 17.10.2022 r.","norm_bases":["PB-08 wydanie 10 z dnia 17.10.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – powietrze atmosferyczne Stężenie pyłu Zakres: (0,01 − 10) mg/m3 Metoda filtracyjno-wagowa PB-08 wydanie 10 z dnia 17.10.2022 r. Srodowisko ogolne – powietrze atmosferyczne Stezenie pylu Zakres: (0,01 − 10) mg/m3 Metoda filtracyjno-wagowa PB-08 wydanie 10 z dnia 17.10.2022 r.","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – ambient air Dust concentration Range: (0,01 − 10) mg/m3 Filtration-gravimetric method PB-08 wydanie 10 z dnia 17.10.2022 r.","search_zh":"一般环境 － 大气空气 PB-08 wydanie 10 z dnia 17.10.2022 r.","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5a55ed9af9f73f382502c5","lab_id":"69ad52a3de79e566650fb5ca","country":"PL","accr_number":"AB 1134","accr_body":"PCA","test_object":"Środowisko ogólne – powietrze atmosferyczne","test_object_en":"General environment – ambient air","methodology":"Pobieranie próbek do pomiaru stężenia: - pyłu - substancji organicznych - substancji nieorganicznych - metali i ich związków Metoda aspiracyjna","methodology_en":"Sampling for measurement of the concentration of: - dust - organic substances - inorganic substances - metals and their compounds Aspiration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do pomiaru stężenia: - pyłu - substancji organicznych - substancji nieorganicznych - metali i ich związków Metoda aspiracyjna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – powietrze atmosferyczne Pobieranie próbek do pomiaru stężenia: - pyłu - substancji organicznych - substancji nieorganicznych - metali i ich związków Metoda aspiracyjna Srodowisko ogolne – powietrze atmosferyczne Pobieranie probek do pomiaru stezenia: - pylu - substancji organicznych - substancji nieorganicznych - metali i ich zwiazkow Metoda aspiracyjna","categories":["materials","environment"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – ambient air Sampling for measurement of the concentration of: - dust - organic substances - inorganic substances - metals and their compounds Aspiration method","search_zh":"一般环境 － 大气空气","test_object_zh":"一般环境 － 大气空气"}],"has_pdf":true}