🇵🇱 WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ PL
环境水与废水汽车材料与高分子食品与饮料
WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ 是由 PCA 认可的实验室,认可编号 AB 1033(Bydgoszcz,波兰)。认可范围涵盖 34 项检测方法,涉及以下领域:环境、水与废水、汽车、材料与高分子。检测对象包括:Water, water intended for human consumption, swimming pool water、水、生活饮用水、Workplace environment - electromagnetic field in the workspace from…、Workplace environment - electromagnetic field in the workspace from…。
要点速览
- 认可编号: PCA AB 1033
- 认可范围内方法数: 34
- 检测对象种类: 13
- 城市: Bydgoszcz, 波兰
- 认可编号
- AB 1033
- 认可机构
- PCA
- 地址
- W BYDGOSZCZY, ZESPÓŁ LABORATORYJNY, ul. Gdańska 147
- 城市
- Bydgoszcz, 波兰
该实验室检测什么 (13)
- Water, water intended for human consumption, swimming pool water — 4 项方法
- 水、生活饮用水 — 4 项方法
- Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment — 3 项方法
- Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices — 3 项方法
- Workplace environment - electromagnetic field in the workspace from measurement and control apparatus — 3 项方法
- Workplace environment - electromagnetic field in the workspace from stationary communication equipment — 3 项方法
- Canned products in metal packaging - meat and meat products — 2 项方法
- Canned products in tin packaging - fish products — 2 项方法
- Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves — 2 项方法
- 工作场所环境 — 中等微气候 — 2 项方法
- 工作场所环境 — 噪声 — 2 项方法
- 工作场所环境 — 室内电气照明 — 2 项方法
- 工作场所环境 — 能量消耗 — 2 项方法
认可范围 — 项检测方法 (34)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | 工作场所环境 — 室内电气照明 | Illuminance Range: (5 – 10 000) lx Direct measurement method | PN-83 E 04040.03 | ||
| 2 | 工作场所环境 — 室内电气照明 | Lighting uniformity ( calculated) | |||
| 3 | 工作场所环境 — 噪声 | A-weighted equivalent sound level A-weighted maximum sound level Range: (23 – 136) dB C-weighted peak sound level Range: (68 – 140) dB Direct measurement method | PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3 | ||
| 4 | 工作场所环境 — 噪声 | Noise exposure level referred to: - an 8-hour daily working time (calculated) | |||
| 5 | 工作场所环境 — 中等微气候 | Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 38) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,15 – 0,5) m/s Direct measurement method | PN-EN ISO 7730:2006 | ||
| 6 | 工作场所环境 — 中等微气候 | PMV 指数 PPD 指数(计算值) | |||
| 7 | 工作场所环境 — 能量消耗 | Air temperature Range: (5 - 35) °C Air flow Range: (10 - 60) dm3/min Direct measurement method | PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r. | ||
| 8 | 工作场所环境 — 能量消耗 | 能量消耗(计算值) | |||
| 9 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method | NO-06-A215-2 | ||
| 10 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method | |||
| 11 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated) | |||
| 12 | Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment | Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method | NO-06-A215-2 | ||
| 13 | Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment | Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method | |||
| 14 | Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment | Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated) | |||
| 15 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Electric field strength: - in the frequency range from 1,6 MHz to 3 GHz Range: (0,5 - 900) V/m Direct measurement method | NO-06-A215-2 | ||
| 16 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Magnetic field strength: - in the frequency range from 1,6 MHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method | |||
| 17 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Magnetic field strength: - in the frequency range from 0,8 GHz to 3 GHz (calculated) | |||
| 18 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method | NO-06-A215-2 | ||
| 19 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method | |||
| 20 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated) | |||
| 21 | Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves | Leak tightness of the packaging Vacuum method | PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4 | ||
| 22 | Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves | Durability Incubation test method | PN-A-75052-3:1990 | ||
| 23 | Canned products in tin packaging - fish products | Leak tightness of the packaging Vacuum method | PN-A-86732:1992 pkt.2.3.10 | ||
| 24 | Canned products in tin packaging - fish products | Durability Incubation test method | PN-A-86732:1992 pkt. 2.3.11 | ||
| 25 | Canned products in metal packaging - meat and meat products | Leak tightness of the packaging Vacuum method | PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3 | ||
| 26 | Canned products in metal packaging - meat and meat products | Durability Incubation test method | PN-A-82055-5:1994 | ||
| 27 | Water, water intended for human consumption, swimming pool water | Total count of microorganisms at 360C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 28 | Water, water intended for human consumption, swimming pool water | Total count of microorganisms at 220C Plate method (pour plate) | |||
| 29 | 水、生活饮用水 | Electrical conductivity Range: (20 – 2000)μS/cm Conductometric method | PN-EN 27888:1999 | ||
| 30 | 水、生活饮用水 | Nitrite concentration Range: (0,005 - 0,120)mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 31 | 水、生活饮用水 | True colour Range: (2 – 100) mg/l Pt Spectrophotometric method | PN-EN ISO 7887: 2012 + Ap1:2015-06 | ||
| 32 | 水、生活饮用水 | Ammonium ion concentration Range: (0,05 – 2,50) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 33 | Water, water intended for human consumption, swimming pool water | Total iron concentration Range: (0,010 – 4,0) mg/l Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | ||
| 34 | Water, water intended for human consumption, swimming pool water | pH 范围:4,0 – 10,0 电位法 | PN-EN ISO 10523:2012 | ||
引用标准 (18)
NO-06-A215-2
PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r.
PN-83 E 04040.03
PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4
PN-A-75052-3:1990
PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3
PN-A-82055-5:1994
PN-A-86732:1992 pkt. 2.3.11
PN-A-86732:1992 pkt.2.3.10
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 6222:2004
PN-EN ISO 7730:2006
PN-EN ISO 7887: 2012 + Ap1:2015-06
PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002