🇵🇱 WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ PL

PCA AB 1033 • Bydgoszcz, 波兰 • 34 项方法

环境水与废水汽车材料与高分子食品与饮料

WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ 是由 PCA 认可的实验室,认可编号 AB 1033(Bydgoszcz,波兰)。认可范围涵盖 34 项检测方法,涉及以下领域:环境、水与废水、汽车、材料与高分子。检测对象包括:Water, water intended for human consumption, swimming pool water、水、生活饮用水、Workplace environment - electromagnetic field in the workspace from…、Workplace environment - electromagnetic field in the workspace from…。

要点速览

  • 认可编号: PCA AB 1033
  • 认可范围内方法数: 34
  • 检测对象种类: 13
  • 城市: Bydgoszcz, 波兰
认可编号
AB 1033
认可机构
PCA
地址
W BYDGOSZCZY, ZESPÓŁ LABORATORYJNY, ul. Gdańska 147
城市
Bydgoszcz, 波兰

该实验室检测什么 (13)

认可范围 — 项检测方法 (34)

序号 检测对象 方法 / 参数 技术 依据文件
检测方法
1 工作场所环境 — 室内电气照明 Illuminance Range: (5 – 10 000) lx Direct measurement method PN-83 E 04040.03
2 工作场所环境 — 室内电气照明 Lighting uniformity ( calculated)
3 工作场所环境 — 噪声 A-weighted equivalent sound level A-weighted maximum sound level Range: (23 – 136) dB C-weighted peak sound level Range: (68 – 140) dB Direct measurement method PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3
4 工作场所环境 — 噪声 Noise exposure level referred to: - an 8-hour daily working time (calculated)
5 工作场所环境 — 中等微气候 Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 38) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,15 – 0,5) m/s Direct measurement method PN-EN ISO 7730:2006
6 工作场所环境 — 中等微气候 PMV 指数 PPD 指数(计算值)
7 工作场所环境 — 能量消耗 Air temperature Range: (5 - 35) °C Air flow Range: (10 - 60) dm3/min Direct measurement method PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r.
8 工作场所环境 — 能量消耗 能量消耗(计算值)
9 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method NO-06-A215-2
10 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method
11 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)
12 Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method NO-06-A215-2
13 Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method
14 Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)
15 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Electric field strength: - in the frequency range from 1,6 MHz to 3 GHz Range: (0,5 - 900) V/m Direct measurement method NO-06-A215-2
16 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength: - in the frequency range from 1,6 MHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method
17 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength: - in the frequency range from 0,8 GHz to 3 GHz (calculated)
18 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method NO-06-A215-2
19 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method
20 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)
21 Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves Leak tightness of the packaging Vacuum method PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4
22 Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves Durability Incubation test method PN-A-75052-3:1990
23 Canned products in tin packaging - fish products Leak tightness of the packaging Vacuum method PN-A-86732:1992 pkt.2.3.10
24 Canned products in tin packaging - fish products Durability Incubation test method PN-A-86732:1992 pkt. 2.3.11
25 Canned products in metal packaging - meat and meat products Leak tightness of the packaging Vacuum method PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3
26 Canned products in metal packaging - meat and meat products Durability Incubation test method PN-A-82055-5:1994
27 Water, water intended for human consumption, swimming pool water Total count of microorganisms at 360C Plate method (pour plate) PN-EN ISO 6222:2004
28 Water, water intended for human consumption, swimming pool water Total count of microorganisms at 220C Plate method (pour plate)
29 水、生活饮用水 Electrical conductivity Range: (20 – 2000)μS/cm Conductometric method PN-EN 27888:1999
30 水、生活饮用水 Nitrite concentration Range: (0,005 - 0,120)mg/l Spectrophotometric method PN-EN 26777:1999
31 水、生活饮用水 True colour Range: (2 – 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887: 2012 + Ap1:2015-06
32 水、生活饮用水 Ammonium ion concentration Range: (0,05 – 2,50) mg/l Spectrophotometric method PN-ISO 7150-1:2002
33 Water, water intended for human consumption, swimming pool water Total iron concentration Range: (0,010 – 4,0) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
34 Water, water intended for human consumption, swimming pool water pH 范围:4,0 – 10,0 电位法 PN-EN ISO 10523:2012

引用标准 (18)

NO-06-A215-2
PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r.
PN-83 E 04040.03
PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4
PN-A-75052-3:1990
PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3
PN-A-82055-5:1994
PN-A-86732:1992 pkt. 2.3.11
PN-A-86732:1992 pkt.2.3.10
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 6222:2004
PN-EN ISO 7730:2006
PN-EN ISO 7887: 2012 + Ap1:2015-06
PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002