{"lab":{"_id":"69ad52a3de79e566650fb536","accr_number":"AB 1033","country":"PL","accr_body":"PCA","address":"W BYDGOSZCZY, ZESPÓŁ LABORATORYJNY, ul. Gdańska 147","categories":["environment","water","automotive","materials","food"],"city":"Bydgoszcz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":34,"name":"WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1033.pdf"],"scope_summary":"","search_text":"wojskowy ośrodek medycyny prewencyjnej w bydgoszczy, zespół laboratoryjny, ul. gdańska 147 environment pharma electronics metrology other automotive water food","status":"active","updated_at":"2026-03-08T14:50:12.766Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:12.766Z","parse_date":"2026-07-17T16:19:14.429Z","parse_source":"m5-mistral-qa","needs_review":true,"review_reason":"brak e-maila — do znalezienia","email_confidence":"high","email_mx":true,"email_source":"https://womp-bydgoszcz.wp.mil.pl/kontakt-2017-01-16-4/","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, mikroklimat, wydatek energetyczny, pole elektromagnetyczne","en":"Tests concerning environmental engineering (environmental and climatic) – workplace (harmful and nuisance factors – noise, lighting, microclimate, energy expenditure, electromagnetic field."},{"codes":"C/28; C/29","pl":"Badania chemiczne wody, woda do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"K/28; K/29; K/22","pl":"Badania mikrobiologiczne wody, woda do spożycia przez ludzi, żywności","en":"Microbiological tests of water, drinking water, food"},{"codes":"N/28, N/29","pl":"Badania właściwości fizycznych wody, woda do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"M /22","pl":"Badania inne żywności","en":"Other tests of food"}],"issue":{"no":"21","date":"03.04.2025"},"map_coord":[53.138919,18.015496],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":20,"water":8,"other":4,"automotive":3,"materials":2,"food":2},"category_scores":{"environment":10.26,"water":1.64,"other":0.41,"automotive":0.23,"materials":0.1,"food":0.1},"has_zh":true},"methods":[{"_id":"6a5a56029af9f73f38254219","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Natężenie oświetlenia Zakres: (5 – 10 000) lx Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (5 – 10 000) lx Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (5 – 10 000) lx Metoda pomiarowa bezpośrednia","reference":"PN-83 E 04040.03","norm_bases":["PN-83 E 04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia Zakres: (5 – 10 000) lx Metoda pomiarowa bezpośrednia PN-83 E 04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia Zakres: (5 – 10 000) lx Metoda pomiarowa bezposrednia PN-83 E 04040.03","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - indoor electric lighting Illuminance Range: (5 – 10 000) lx Direct measurement method PN-83 E 04040.03","search_zh":"工作场所环境 — 室内电气照明 照度 范围：(5 – 10 000) lx 直接测量法 PN-83 E 04040.03","test_object_zh":"工作场所环境 — 室内电气照明","methodology_zh":"照度 范围：(5 – 10 000) lx 直接测量法"},{"_id":"6a5a56029af9f73f3825421a","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Równomierność oświetlenia ( z obliczeń)","methodology_en":"Lighting uniformity ( calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia ( z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia ( z obliczeń) Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia ( z obliczen)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - indoor electric lighting Lighting uniformity ( calculated)","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（由计算得出）","test_object_zh":"工作场所环境 — 室内电气照明","methodology_zh":"照度均匀度（由计算得出）"},{"_id":"6a5a56029af9f73f3825421b","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (23 – 136) dB Szczytowy poziom dźwięku C Zakres: (68 – 140) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level Range: (23 – 136) dB C-weighted peak sound level Range: (68 – 140) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (23 – 136) dB Szczytowy poziom dźwięku C Zakres: (68 – 140) dB Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3","norm_bases":["PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (23 – 136) dB Szczytowy poziom dźwięku C Zakres: (68 – 140) dB Metoda pomiarowa bezpośrednia PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Zakres: (23 – 136) dB Szczytowy poziom dzwieku C Zakres: (68 – 140) dB Metoda pomiarowa bezposrednia PN-EN ISO 9612:2011 z wylaczeniem strategii 2 i 3","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (23 – 136) dB C-weighted peak sound level Range: (68 – 140) dB Direct measurement method PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3","search_zh":"工作场所环境 — 噪声 PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a56029af9f73f3825421c","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy (z obliczeń)","methodology_en":"Noise exposure level referred to: - an 8-hour daily working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy (z obliczeń) Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise Noise exposure level referred to: - an 8-hour daily working time (calculated)","search_zh":"工作场所环境 — 噪声 噪声暴露级，参照：－ 每日 8 小时工作时间（由计算得出）","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"噪声暴露级，参照：－ 每日 8 小时工作时间（由计算得出）"},{"_id":"6a5a56029af9f73f3825421d","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","test_object_en":"Workplace environment - moderate microclimate","methodology":"Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 38) °C Wilgotność powietrza Zakres: (25 – 75) % Prędkość powietrza Zakres: (0,15 – 0,5) m/s Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 38) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,15 – 0,5) m/s Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 38) °C Wilgotność powietrza Zakres: (25 – 75) % Prędkość powietrza Zakres: (0,15 – 0,5) m/s Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 38) °C Wilgotność powietrza Zakres: (25 – 75) % Prędkość powietrza Zakres: (0,15 – 0,5) m/s Metoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 38) °C Wilgotnosc powietrza Zakres: (25 – 75) % Predkosc powietrza Zakres: (0,15 – 0,5) m/s Metoda pomiarowa bezposrednia PN-EN ISO 7730:2006","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - moderate microclimate Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 38) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,15 – 0,5) m/s Direct measurement method PN-EN ISO 7730:2006","search_zh":"工作场所环境 — 中等微气候 PN-EN ISO 7730:2006","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5a56029af9f73f3825421e","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","test_object_en":"Workplace environment - moderate microclimate","methodology":"Wskaźnik PMV Wskaźnik PPD (z obliczeń)","methodology_en":"PMV index PPD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV Wskaźnik PPD (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV Wskaźnik PPD (z obliczeń) Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV Wskaznik PPD (z obliczen)","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - moderate microclimate PMV index PPD index (calculated)","search_zh":"工作场所环境 — 中等微气候 PMV 指数 PPD 指数（计算值）","test_object_zh":"工作场所环境 — 中等微气候","methodology_zh":"PMV 指数 PPD 指数（计算值）"},{"_id":"6a5a56029af9f73f3825421f","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","test_object_en":"Workplace environment - energy expenditure","methodology":"Temperatura powietrza Zakres: (5 - 35) °C Przepływ powietrza Zakres: (10 - 60) dm3/min Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (5 - 35) °C Air flow Range: (10 - 60) dm3/min Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (5 - 35) °C Przepływ powietrza Zakres: (10 - 60) dm3/min Metoda pomiarowa bezpośrednia","reference":"PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r.","norm_bases":["PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - wydatek energetyczny Temperatura powietrza Zakres: (5 - 35) °C Przepływ powietrza Zakres: (10 - 60) dm3/min Metoda pomiarowa bezpośrednia PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r. Srodowisko pracy - wydatek energetyczny Temperatura powietrza Zakres: (5 - 35) °C Przeplyw powietrza Zakres: (10 - 60) dm3/min Metoda pomiarowa bezposrednia PB – 03/LBS wydanie 3 z dnia 10.10.2023 r.","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - energy expenditure Air temperature Range: (5 - 35) °C Air flow Range: (10 - 60) dm3/min Direct measurement method PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r.","search_zh":"工作场所环境 — 能量消耗 PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r.","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a5a56029af9f73f38254220","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","test_object_en":"Workplace environment - energy expenditure","methodology":"Wydatek energetyczny (z obliczeń)","methodology_en":"Energy expenditure (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczeń) Srodowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczen)","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - energy expenditure Energy expenditure (calculated)","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值）","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a5a56029af9f73f38254221","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie częstotliwości od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie częstotliwości od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezpośrednia","reference":"NO-06-A215-2","norm_bases":["NO-06-A215-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie częstotliwości od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezpośrednia NO-06-A215-2 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola elektrycznego: - w zakresie czestotliwosci od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie czestotliwosci od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezposrednia NO-06-A215-2","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method NO-06-A215-2","search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 电场强度：－ 频率范围 100 kHz 至 6 GHz 范围：(0,5 - 900) V/m － 频率范围 3 MHz 至 60 GHz 范围：(0,8 - 900) V/m 直接测量法 NO-06-A215-2","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场","methodology_zh":"电场强度：－ 频率范围 100 kHz 至 6 GHz 范围：(0,5 - 900) V/m － 频率范围 3 MHz 至 60 GHz 范围：(0,8 - 900) V/m 直接测量法"},{"_id":"6a5a56029af9f73f38254222","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia","methodology_en":"Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola magnetycznego: - w zakresie częstotliwości od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola magnetycznego: - w zakresie czestotliwosci od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezposrednia","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method","search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 磁场强度：－ 频率范围 300 kHz 至 1 GHz 范围：(0,017 - 16) A/m 直接测量法","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场","methodology_zh":"磁场强度：－ 频率范围 300 kHz 至 1 GHz 范围：(0,017 - 16) A/m 直接测量法"},{"_id":"6a5a56029af9f73f38254223","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 60 GHz (z obliczeń)","methodology_en":"Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 60 GHz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od stacjonarnych urządzeń łączności Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 60 GHz (z obliczeń) Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od stacjonarnych urzadzen lacznosci Natezenie pola magnetycznego: - w zakresie czestotliwosci od 0,8 GHz do 60 GHz (z obliczen)","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)","search_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场 磁场强度：－ 频率范围 0,8 GHz 至 60 GHz（由计算得出）","test_object_zh":"工作环境 － 作业空间内由固定式通信设备产生的电磁场","methodology_zh":"磁场强度：－ 频率范围 0,8 GHz 至 60 GHz（由计算得出）"},{"_id":"6a5a56029af9f73f38254224","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od - mobilnych urządzeń łączności - pojazdów ze środkami łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie częstotliwości od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie częstotliwości od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezpośrednia","reference":"NO-06-A215-2","norm_bases":["NO-06-A215-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od - mobilnych urządzeń łączności - pojazdów ze środkami łączności Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie częstotliwości od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezpośrednia NO-06-A215-2 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od - mobilnych urzadzen lacznosci - pojazdow ze srodkami lacznosci Natezenie pola elektrycznego: - w zakresie czestotliwosci od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie czestotliwosci od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezposrednia NO-06-A215-2","categories":["environment","automotive"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method NO-06-A215-2","methodology_zh":"电场强度：－ 频率范围 100 kHz 至 6 GHz 范围：(0,5 - 900) V/m － 频率范围 3 MHz 至 60 GHz 范围：(0,8 - 900) V/m 直接测量法","search_zh":"工作环境 － 作业空间内由下列来源产生的电磁场 － 移动通信设备 － 载有通信设备的车辆 电场强度：－ 频率范围 100 kHz 至 6 GHz 范围：(0,5 - 900) V/m － 频率范围 3 MHz 至 60 GHz 范围：(0,8 - 900) V/m 直接测量法 NO-06-A215-2","test_object_zh":"工作环境 － 作业空间内由下列来源产生的电磁场 － 移动通信设备 － 载有通信设备的车辆"},{"_id":"6a5a56029af9f73f38254225","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od - mobilnych urządzeń łączności - pojazdów ze środkami łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia","methodology_en":"Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od - mobilnych urządzeń łączności - pojazdów ze środkami łączności Natężenie pola magnetycznego: - w zakresie częstotliwości od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od - mobilnych urzadzen lacznosci - pojazdow ze srodkami lacznosci Natezenie pola magnetycznego: - w zakresie czestotliwosci od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezposrednia","categories":["environment","automotive"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method","methodology_zh":"磁场强度：－ 频率范围 300 kHz 至 1 GHz 范围：(0,017 - 16) A/m 直接测量法","search_zh":"工作环境 － 作业空间内由下列来源产生的电磁场 － 移动通信设备 － 载有通信设备的车辆 磁场强度：－ 频率范围 300 kHz 至 1 GHz 范围：(0,017 - 16) A/m 直接测量法","test_object_zh":"工作环境 － 作业空间内由下列来源产生的电磁场 － 移动通信设备 － 载有通信设备的车辆"},{"_id":"6a5a56029af9f73f38254226","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od - mobilnych urządzeń łączności - pojazdów ze środkami łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 60 GHz (z obliczeń)","methodology_en":"Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 60 GHz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od - mobilnych urządzeń łączności - pojazdów ze środkami łączności Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 60 GHz (z obliczeń) Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od - mobilnych urzadzen lacznosci - pojazdow ze srodkami lacznosci Natezenie pola magnetycznego: - w zakresie czestotliwosci od 0,8 GHz do 60 GHz (z obliczen)","categories":["environment","automotive"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)","methodology_zh":"磁场强度：－ 频率范围 0,8 GHz 至 60 GHz（由计算得出）","search_zh":"工作环境 － 作业空间内由下列来源产生的电磁场 － 移动通信设备 － 载有通信设备的车辆 磁场强度：－ 频率范围 0,8 GHz 至 60 GHz（由计算得出）","test_object_zh":"工作环境 － 作业空间内由下列来源产生的电磁场 － 移动通信设备 － 载有通信设备的车辆"},{"_id":"6a5a56029af9f73f38254227","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 1,6 MHz do 3 GHz Zakres: (0,5 - 900) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: - in the frequency range from 1,6 MHz to 3 GHz Range: (0,5 - 900) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 1,6 MHz do 3 GHz Zakres: (0,5 - 900) V/m Metoda pomiarowa bezpośrednia","reference":"NO-06-A215-2","norm_bases":["NO-06-A215-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności Natężenie pola elektrycznego: - w zakresie częstotliwości od 1,6 MHz do 3 GHz Zakres: (0,5 - 900) V/m Metoda pomiarowa bezpośrednia NO-06-A215-2 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci Natezenie pola elektrycznego: - w zakresie czestotliwosci od 1,6 MHz do 3 GHz Zakres: (0,5 - 900) V/m Metoda pomiarowa bezposrednia NO-06-A215-2","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Electric field strength: - in the frequency range from 1,6 MHz to 3 GHz Range: (0,5 - 900) V/m Direct measurement method NO-06-A215-2","search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场 NO-06-A215-2","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场"},{"_id":"6a5a56029af9f73f38254228","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 1,6 MHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia","methodology_en":"Magnetic field strength: - in the frequency range from 1,6 MHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 1,6 MHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności Natężenie pola magnetycznego: - w zakresie częstotliwości od 1,6 MHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci Natezenie pola magnetycznego: - w zakresie czestotliwosci od 1,6 MHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezposrednia","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength: - in the frequency range from 1,6 MHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method","search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场"},{"_id":"6a5a56029af9f73f38254229","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności","test_object_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 3 GHz (z obliczeń)","methodology_en":"Magnetic field strength: - in the frequency range from 0,8 GHz to 3 GHz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 3 GHz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od doręcznych i przenośnych środków łączności Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 3 GHz (z obliczeń) Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od dorecznych i przenosnych srodkow lacznosci Natezenie pola magnetycznego: - w zakresie czestotliwosci od 0,8 GHz do 3 GHz (z obliczen)","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength: - in the frequency range from 0,8 GHz to 3 GHz (calculated)","search_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场","test_object_zh":"工作环境 － 作业空间内由手持式与便携式通信设备产生的电磁场"},{"_id":"6a5a56029af9f73f3825422a","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej","test_object_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie częstotliwości od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie częstotliwości od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezpośrednia","reference":"NO-06-A215-2","norm_bases":["NO-06-A215-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie częstotliwości od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezpośrednia NO-06-A215-2 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od aparatury kontrolno-pomiarowej Natezenie pola elektrycznego: - w zakresie czestotliwosci od 100 kHz do 6 GHz Zakres: (0,5 - 900) V/m - w zakresie czestotliwosci od 3 MHz do 60 GHz Zakres: (0,8 - 900) V/m Metoda pomiarowa bezposrednia NO-06-A215-2","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method NO-06-A215-2","search_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场 电场强度：－ 频率范围 100 kHz 至 6 GHz 范围：(0,5 - 900) V/m － 频率范围 3 MHz 至 60 GHz 范围：(0,8 - 900) V/m 直接测量法 NO-06-A215-2","test_object_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场","methodology_zh":"电场强度：－ 频率范围 100 kHz 至 6 GHz 范围：(0,5 - 900) V/m － 频率范围 3 MHz 至 60 GHz 范围：(0,8 - 900) V/m 直接测量法"},{"_id":"6a5a56029af9f73f3825422b","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej","test_object_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia","methodology_en":"Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej Natężenie pola magnetycznego: - w zakresie częstotliwości od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezpośrednia Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od aparatury kontrolno-pomiarowej Natezenie pola magnetycznego: - w zakresie czestotliwosci od 300 kHz do 1 GHz Zakres: (0,017 - 16) A/m Metoda pomiarowa bezposrednia","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method","search_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场 磁场强度：－ 频率范围 300 kHz 至 1 GHz 范围：(0,017 - 16) A/m 直接测量法","test_object_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场","methodology_zh":"磁场强度：－ 频率范围 300 kHz 至 1 GHz 范围：(0,017 - 16) A/m 直接测量法"},{"_id":"6a5a56029af9f73f3825422c","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej","test_object_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 60 GHz (z obliczeń)","methodology_en":"Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 60 GHz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od aparatury kontrolno-pomiarowej Natężenie pola magnetycznego: - w zakresie częstotliwości od 0,8 GHz do 60 GHz (z obliczeń) Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od aparatury kontrolno-pomiarowej Natezenie pola magnetycznego: - w zakresie czestotliwosci od 0,8 GHz do 60 GHz (z obliczen)","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)","search_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场 磁场强度：－ 频率范围 0,8 GHz 至 60 GHz（由计算得出）","test_object_zh":"工作环境 － 作业空间内由检测与测量仪器产生的电磁场","methodology_zh":"磁场强度：－ 频率范围 0,8 GHz 至 60 GHz（由计算得出）"},{"_id":"6a5a56029af9f73f3825422d","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Konserwy w opakowaniach blaszanych - przetwory owocowe, warzywne i warzywno-mięsne","test_object_en":"Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves","methodology":"Szczelność opakowania Metoda próżniowa","methodology_en":"Leak tightness of the packaging Vacuum method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność opakowania Metoda próżniowa","reference":"PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4","norm_bases":["PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Konserwy w opakowaniach blaszanych - przetwory owocowe, warzywne i warzywno-mięsne Szczelność opakowania Metoda próżniowa PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4 Konserwy w opakowaniach blaszanych - przetwory owocowe, warzywne i warzywno-miesne Szczelnosc opakowania Metoda prozniowa PN-A-75052-2:1990 z wylaczeniem pkt. 2.2.3 i pkt. 2.2.4","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves Leak tightness of the packaging Vacuum method PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4","methodology_zh":"包装密封性 真空法","search_zh":"包装密封性 真空法 PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4"},{"_id":"6a5a56029af9f73f3825422e","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Konserwy w opakowaniach blaszanych - przetwory owocowe, warzywne i warzywno-mięsne","test_object_en":"Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves","methodology":"Trwałość Metoda próby termostatowej","methodology_en":"Durability Incubation test method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość Metoda próby termostatowej","reference":"PN-A-75052-3:1990","norm_bases":["PN-A-75052-3:1990"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Konserwy w opakowaniach blaszanych - przetwory owocowe, warzywne i warzywno-mięsne Trwałość Metoda próby termostatowej PN-A-75052-3:1990 Konserwy w opakowaniach blaszanych - przetwory owocowe, warzywne i warzywno-miesne Trwalosc Metoda proby termostatowej PN-A-75052-3:1990","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves Durability Incubation test method PN-A-75052-3:1990","methodology_zh":"保藏性 恒温培养试验法","search_zh":"保藏性 恒温培养试验法 PN-A-75052-3:1990"},{"_id":"6a5a56029af9f73f3825422f","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Konserwy w opakowaniach blaszanych - przetwory rybne","test_object_en":"Canned products in tin packaging - fish products","methodology":"Szczelność opakowania Metoda próżniowa","methodology_en":"Leak tightness of the packaging Vacuum method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność opakowania Metoda próżniowa","reference":"PN-A-86732:1992 pkt.2.3.10","norm_bases":["PN-A-86732:1992 pkt.2.3.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Konserwy w opakowaniach blaszanych - przetwory rybne Szczelność opakowania Metoda próżniowa PN-A-86732:1992 pkt.2.3.10 Konserwy w opakowaniach blaszanych - przetwory rybne Szczelnosc opakowania Metoda prozniowa PN-A-86732:1992 pkt.2.3.10","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Canned products in tin packaging - fish products Leak tightness of the packaging Vacuum method PN-A-86732:1992 pkt.2.3.10","methodology_zh":"包装密封性 真空法","search_zh":"包装密封性 真空法 PN-A-86732:1992 pkt.2.3.10"},{"_id":"6a5a56029af9f73f38254230","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Konserwy w opakowaniach blaszanych - przetwory rybne","test_object_en":"Canned products in tin packaging - fish products","methodology":"Trwałość Metoda próby termostatowej","methodology_en":"Durability Incubation test method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość Metoda próby termostatowej","reference":"PN-A-86732:1992 pkt. 2.3.11","norm_bases":["PN-A-86732:1992 pkt. 2.3.11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Konserwy w opakowaniach blaszanych - przetwory rybne Trwałość Metoda próby termostatowej PN-A-86732:1992 pkt. 2.3.11 Konserwy w opakowaniach blaszanych - przetwory rybne Trwalosc Metoda proby termostatowej PN-A-86732:1992 pkt. 2.3.11","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Canned products in tin packaging - fish products Durability Incubation test method PN-A-86732:1992 pkt. 2.3.11","methodology_zh":"保藏性 恒温培养试验法","search_zh":"保藏性 恒温培养试验法 PN-A-86732:1992 pkt. 2.3.11"},{"_id":"6a5a56029af9f73f38254231","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Konserwy w opakowaniach metalowych - mięso i przetwory mięsne","test_object_en":"Canned products in metal packaging - meat and meat products","methodology":"Szczelność opakowania Metoda próżniowa","methodology_en":"Leak tightness of the packaging Vacuum method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność opakowania Metoda próżniowa","reference":"PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3","norm_bases":["PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Konserwy w opakowaniach metalowych - mięso i przetwory mięsne Szczelność opakowania Metoda próżniowa PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3 Konserwy w opakowaniach metalowych - mieso i przetwory miesne Szczelnosc opakowania Metoda prozniowa PN-A-82055-4:1997 z wylaczeniem pkt. 2.4.1.3","categories":["materials","food"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Canned products in metal packaging - meat and meat products Leak tightness of the packaging Vacuum method PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3","methodology_zh":"包装密封性 真空法","search_zh":"包装密封性 真空法 PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3"},{"_id":"6a5a56029af9f73f38254232","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Konserwy w opakowaniach metalowych - mięso i przetwory mięsne","test_object_en":"Canned products in metal packaging - meat and meat products","methodology":"Trwałość Metoda próby termostatowej","methodology_en":"Durability Incubation test method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość Metoda próby termostatowej","reference":"PN-A-82055-5:1994","norm_bases":["PN-A-82055-5:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Konserwy w opakowaniach metalowych - mięso i przetwory mięsne Trwałość Metoda próby termostatowej PN-A-82055-5:1994 Konserwy w opakowaniach metalowych - mieso i przetwory miesne Trwalosc Metoda proby termostatowej PN-A-82055-5:1994","categories":["materials","food"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Canned products in metal packaging - meat and meat products Durability Incubation test method PN-A-82055-5:1994","methodology_zh":"保藏性 恒温培养试验法","search_zh":"保藏性 恒温培养试验法 PN-A-82055-5:1994"},{"_id":"6a5a56029af9f73f38254233","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, woda na pływalniach","test_object_en":"Water, water intended for human consumption, swimming pool water","methodology":"Ogólna liczba mikroorganizmów w temp. 360C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total count of microorganisms at 360C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 360C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, woda na pływalniach Ogólna liczba mikroorganizmów w temp. 360C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi, woda na plywalniach Ogolna liczba mikroorganizmow w temp. 360C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, swimming pool water Total count of microorganisms at 360C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水、游泳池水 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5a56029af9f73f38254234","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, woda na pływalniach","test_object_en":"Water, water intended for human consumption, swimming pool water","methodology":"Ogólna liczba mikroorganizmów w temp.220C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total count of microorganisms at 220C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp.220C Metoda płytkowa (posiew wgłębny)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, woda na pływalniach Ogólna liczba mikroorganizmów w temp.220C Metoda płytkowa (posiew wgłębny) Woda, woda do spozycia przez ludzi, woda na plywalniach Ogolna liczba mikroorganizmow w temp.220C Metoda plytkowa (posiew wglebny)","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, swimming pool water Total count of microorganisms at 220C Plate method (pour plate)","search_zh":"水、生活饮用水、游泳池水","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5a56029af9f73f38254235","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa Zakres: (20 – 2000)μS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (20 – 2000)μS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (20 – 2000)μS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa Zakres: (20 – 2000)μS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa Zakres: (20 – 2000)μS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Electrical conductivity Range: (20 – 2000)μS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、生活饮用水 PN-EN 27888:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f38254236","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotynów Zakres: (0,005 - 0,120)mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,005 - 0,120)mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,005 - 0,120)mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów Zakres: (0,005 - 0,120)mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow Zakres: (0,005 - 0,120)mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Nitrite concentration Range: (0,005 - 0,120)mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水、生活饮用水 PN-EN 26777:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f38254237","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa rzeczywista Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna","methodology_en":"True colour Range: (2 – 100) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa rzeczywista Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887: 2012 + Ap1:2015-06","norm_bases":["PN-EN ISO 7887: 2012 + Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa rzeczywista Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887: 2012 + Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa rzeczywista Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887: 2012 + Ap1:2015-06","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption True colour Range: (2 – 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887: 2012 + Ap1:2015-06","search_zh":"水、生活饮用水 PN-EN ISO 7887: 2012 + Ap1:2015-06","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f38254238","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonów amonowych Zakres: (0,05 – 2,50) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,05 – 2,50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonów amonowych Zakres: (0,05 – 2,50) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonów amonowych Zakres: (0,05 – 2,50) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonow amonowych Zakres: (0,05 – 2,50) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Ammonium ion concentration Range: (0,05 – 2,50) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水、生活饮用水 PN-ISO 7150-1:2002","test_object_zh":"水、生活饮用水"},{"_id":"6a5a56029af9f73f38254239","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, woda na pływalniach","test_object_en":"Water, water intended for human consumption, swimming pool water","methodology":"Stężenie żelaza ogólnego Zakres: (0,010 – 4,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (0,010 – 4,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (0,010 – 4,0) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, woda na pływalniach Stężenie żelaza ogólnego Zakres: (0,010 – 4,0) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi, woda na plywalniach Stezenie zelaza ogolnego Zakres: (0,010 – 4,0) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, swimming pool water Total iron concentration Range: (0,010 – 4,0) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06","search_zh":"水、生活饮用水、游泳池水 PN-ISO 6332:2001+Ap1:2016-06","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5a56029af9f73f3825423a","lab_id":"69ad52a3de79e566650fb536","country":"PL","accr_number":"AB 1033","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, woda na pływalniach","test_object_en":"Water, water intended for human consumption, swimming pool water","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, woda na pływalniach pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, woda na plywalniach pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, swimming pool water pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","methodology_zh":"pH 范围：4,0 – 10,0 电位法","search_zh":"水、生活饮用水、游泳池水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、生活饮用水、游泳池水"}],"has_pdf":true}