CENTRALNY INSTYTUT OCHRONY PRACY 是由 PCA 认可的实验室,认可编号 AB 038(Warszawa,波兰)。认可范围涵盖 43 项检测方法,涉及以下领域:环境。检测对象包括:工作环境 - 非激光光辐射 Working environment Non-laser optical radiation、带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with…、带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus w…、配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air…。

要点速览

  • 认可编号: PCA AB 038
  • 认可范围内方法数: 43
  • 检测对象种类: 13
  • 城市: Warszawa, 波兰
认可编号
AB 038
认可机构
PCA
地址
- PAŃSTWOWY INSTYTUT BADAWCZY, ul. Czerniakowska 16, 00-701 Warszawa
城市
Warszawa, 波兰

该实验室检测什么 (13)

认可范围 — 项检测方法 (43)

序号 检测对象 方法 / 参数 技术 依据文件
检测方法
1 Work station – noise A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11
2 Work station – noise Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)
3 Work station – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method PN-Z-01339:2020
4 环境 - 无线电通信设施周围的电磁场:宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban Electric field strength: - in the frequency range from 100 kHz to 18 GHz Range: (0,6-100) V/m Direct measurement method Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17
5 环境 - 无线电通信设施周围的电磁场:宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban Magnetic field strength: - in the frequency range from 100 kHz to 1 GHz Range: (0,01-10) A/m Direct measurement method Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method
6 环境 - 无线电通信设施周围的电磁场:宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban Magnetic field strength: - in the frequency range from 1 GHz to 18 GHz Range: (0,01-0,26) A/m Measurement and calculation method Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method
7 Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Electric field strength: - in the frequency range from 27 MHz to 6 GHz Range: (0,02-100) V/m Direct measurement method Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17
8 Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Magnetic field strength: - in the frequency range from 9 kHz to 250 MHz Range: (0,001-0,5) A/m Direct measurement method Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method
9 Work station Laser radiation Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01
10 Work station Indoor electrical lighting Illuminance in the range 20 lx-5000 lx Direct measurement method Illuminance in the range 20 lx-5000 lx Direct measurement method Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022
11 Work station Indoor electrical lighting Uniformity of illumination on work station
12 工作环境 - 非激光光辐射 Working environment Non-laser optical radiation Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations) PN-EN 14255-2:2010 Metoda O Method O
13 工作环境 - 非激光光辐射 Working environment Non-laser optical radiation Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R
14 工作环境 - 非激光光辐射 Working environment Non-laser optical radiation Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Radiant exposure to ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40000 nm (calculated) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)
15 工作环境 - 非激光光辐射 Working environment Non-laser optical radiation Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method
16 工作环境 - 非激光光辐射 Working environment Non-laser optical radiation Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r.
17 工作环境 - 非激光光辐射 Working environment Non-laser optical radiation Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method PN-T 05687:2002
18 工作环境 - 非激光光辐射 Working environment Non-laser optical radiation Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)
19 工作环境 - 非激光光辐射 Working environment Non-laser optical radiation Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations) PN-EN 14255-1:2010 Metoda A Method A
20 Working environment Non-laser optical radiation Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Radiant exposure to ultraviolet radiation in the spectral range from 315 nm to 390 nm (calculated) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations) PN-EN 14255-1:2010 Metoda M Method M
21 Working environment- - air samples collected on filters Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection Podstawy i Metody Oceny Środowiska Pracy 2023, nr 1(115) s.5-25
22 Working environment Energy expenditure Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023
23 Working environment Energy expenditure Energy expenditure (from calculation)
24 带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask 运行使用检验 Practical performance EN 14593-1:2018 EN 13274-2:2019
25 带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask 连接强度 Strength of connections EN 14593-1:2018
26 带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask 可燃性 Flammability EN 14593-1:2018 EN 13274-4:2020
27 带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask Inward leakage Inward leakage EN 14593-1:2018 EN 13274-1:2001
28 带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask 呼吸阻力 Breathing resistance EN 14593-1:2018 EN 13274-3:2001
29 带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask Carbon dioxide content of the inhalation air Carbon dioxide content of the inhalation air EN 14593-1:2018 EN 13274-6:2001
30 带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask 耐温度性 Resistance to temperature EN 14593-2:2005
31 带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure 运行使用检验 Practical performance EN 14593-2:2005 EN 13274-2:2019
32 带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure 连接强度 Strength of connections EN 14593-2:2005
33 带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure 可燃性 Flammability EN 14593-2:2005 EN 13274-4:2020
34 带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Inward leakage Inward leakage EN 14593-2:2005 EN 13274-1:2001
35 带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure 呼吸阻力 Breathing resistance EN 14593-2:2005 EN 13274-3:2001
36 带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Carbon dioxide content of the inhalation air Carbon dioxide content of the inhalation air EN 14593-2:2005
37 带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure 耐温度性 Resistance to temperature EN 14593-2:2005
38 配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Mass EN 14435:2004
39 配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only 耐温度性 Resistance to temperature EN 14435:2004 EN 13274-5:2001
40 配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only 连接强度 Strength of connections EN 14435:2004
41 配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only 运行使用检验 Practical performance EN 14435:2004 EN 13274-2:2019
42 配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only 可燃性 Flammability EN 14435:2004 EN 13274-4:2020
43 配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only 呼吸阻力 Breathing resistance EN 14435:2004 EN 13274-3:2001

引用标准 (30)

EN 14435:2004
EN 14435:2004 EN 13274-2:2019
EN 14435:2004 EN 13274-3:2001
EN 14435:2004 EN 13274-4:2020
EN 14435:2004 EN 13274-5:2001
EN 14593-1:2018
EN 14593-1:2018 EN 13274-1:2001
EN 14593-1:2018 EN 13274-2:2019
EN 14593-1:2018 EN 13274-3:2001
EN 14593-1:2018 EN 13274-4:2020
EN 14593-1:2018 EN 13274-6:2001
EN 14593-2:2005
EN 14593-2:2005 EN 13274-1:2001
EN 14593-2:2005 EN 13274-2:2019
EN 14593-2:2005 EN 13274-3:2001
EN 14593-2:2005 EN 13274-4:2020
NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023
PN-EN 14255-1:2010 Metoda A Method A
PN-EN 14255-1:2010 Metoda M Method M
PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R
PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r.
PN-EN 14255-2:2010 Metoda O Method O
PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11
PN-T 05687:2002
PN-Z-01339:2020
Podstawy i Metody Oceny Środowiska Pracy 2023, nr 1(115) s.5-25
Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022
enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17
enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17