{"lab":{"_id":"69ad52a3de79e566650fb0db","accr_number":"AB 038","country":"PL","accr_body":"PCA","address":"- PAŃSTWOWY INSTYTUT BADAWCZY, ul. Czerniakowska 16, 00-701 Warszawa","categories":["environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":43,"name":"CENTRALNY INSTYTUT OCHRONY PRACY","parse_status":"parsed","parse_version":3,"pdf_files":["AB_038.pdf"],"scope_summary":"","search_text":"centralny instytut ochrony pracy - państwowy instytut badawczy, ul. czerniakowska 16, 00-701 warszawa other environment metrology pharma electronics materials construction automotive food water petro","status":"active","updated_at":"2026-03-08T14:50:04.628Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:04.628Z","parse_date":"2026-07-17T16:18:58.996Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://www.ciop.pl/CIOPPortalWAR/appmanager/ciop/pl (Kontakt)","fields_of_testing":[{"codes":"A/19","pl":"Badania akustyczne i drgań środków ochrony osobistej","en":"Acoustic and vibration tests of personal protection equipment"},{"codes":"A/33","pl":"Badania akustyczne i drgań-środowisko pracy (czynniki szkodliwe –hałas)","en":"Acoustic and vibration tests of workplace (harmful factors – noise )"},{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests – working envronment (harmful factors – air)"},{"codes":"E/19","pl":"Badania elektryczne środków ochrony osobistej","en":"Electric tests of electrical products and equipment and personal protection equipment"},{"codes":"G/33; G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne)-środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, pole elektromagnetyczne, oświetlenie, wydatek energetyczny, promieniowanie optyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment , (harmful and nuisance factors – noise, vibration, electromagnetic field, lighting, energy expenditure, optical radiation )"},{"codes":"H/19","pl":"Badania ogniowe środków ochrony osobistej","en":"Fire tests of personal protection equipment"},{"codes":"J/13; J/17; J/19","pl":"Badania mechaniczne maszyn, wyrobów innych i środków ochrony osobistej","en":"Mechanical tests of electrical products and equipment, machinery, other products and personal protection equipment"},{"codes":"N/13; N/19","pl":"Badania właściwości fizycznych maszyn, środków ochrony osobistej","en":"Tests of physical properties of machinery, personal protection equipment"}],"issue":{"no":"27","date":"22.07.2025"},"map_coord":[52.199756,21.051208],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":26,"other":17,"petro":1},"category_scores":{"environment":15.36,"other":6.57,"petro":0.02},"has_zh":true},"methods":[{"_id":"6a5a55f39af9f73f38251536","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy − hałas Work station – noise","test_object_en":"Work station – noise","methodology":"Równoważny poziom dźwięku A Zakres: (40 -136) dB Maksymalny poziom dźwięku A Zakres: (40 -136) dB Szczytowy poziom dźwięku C Zakres: (40 -138) dB Metoda pomiarowa bezpośrednia A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method","methodology_en":"A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (40 -136) dB Maksymalny poziom dźwięku A Zakres: (40 -136) dB Szczytowy poziom dźwięku C Zakres: (40 -138) dB Metoda pomiarowa bezpośrednia A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method","reference":"PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11","norm_bases":["PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy − hałas Work station – noise Równoważny poziom dźwięku A Zakres: (40 -136) dB Maksymalny poziom dźwięku A Zakres: (40 -136) dB Szczytowy poziom dźwięku C Zakres: (40 -138) dB Metoda pomiarowa bezpośrednia A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11 Stanowiska pracy − halas Work station – noise Rownowazny poziom dzwieku A Zakres: (40 -136) dB Maksymalny poziom dzwieku A Zakres: (40 -136) dB Szczytowy poziom dzwieku C Zakres: (40 -138) dB Metoda pomiarowa bezposrednia A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station – noise A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11"},{"_id":"6a5a55f39af9f73f38251537","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy − hałas Work station – noise","test_object_en":"Work station – noise","methodology":"Poziom ekspozycji na hałas odniesiony do:  8-godz. Dobowego wymiaru czasu pracy  przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)","methodology_en":"Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do:  8-godz. Dobowego wymiaru czasu pracy  przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy − hałas Work station – noise Poziom ekspozycji na hałas odniesiony do:  8-godz. Dobowego wymiaru czasu pracy  przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations) Stanowiska pracy − halas Work station – noise Poziom ekspozycji na halas odniesiony do:  8-godz. Dobowego wymiaru czasu pracy  przecietnego tygodniowego wymiaru czasu pracy (z obliczen) Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station – noise Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)"},{"_id":"6a5a55f39af9f73f38251538","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy − hałas ultradźwiękowy Work station – ultrasonic noise","test_object_en":"Work station – ultrasonic noise","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Metoda pomiarowa bezpośrednia Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method","methodology_en":"Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Metoda pomiarowa bezpośrednia Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method","reference":"PN-Z-01339:2020","norm_bases":["PN-Z-01339:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy − hałas ultradźwiękowy Work station – ultrasonic noise Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Metoda pomiarowa bezpośrednia Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method PN-Z-01339:2020 Stanowiska pracy − halas ultradzwiekowy Work station – ultrasonic noise Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Maksymalny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Metoda pomiarowa bezposrednia Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method PN-Z-01339:2020","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method PN-Z-01339:2020"},{"_id":"6a5a55f39af9f73f38251539","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","test_object_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 18 GHz Zakres: (0,6-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method","methodology_en":"Electric field strength: - in the frequency range from 100 kHz to 18 GHz Range: (0,6-100) V/m Direct measurement method Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 18 GHz Zakres: (0,6-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method","reference":"enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17","norm_bases":["enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 18 GHz Zakres: (0,6-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17 Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natezenie pola elektrycznego: - w zakresie czestotliwosci od 100 kHz do 18 GHz Zakres: (0,6-100) V/m Metoda pomiarowa bezposrednia Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Electric field strength: - in the frequency range from 100 kHz to 18 GHz Range: (0,6-100) V/m Direct measurement method Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17","search_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17","test_object_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban"},{"_id":"6a5a55f39af9f73f3825153a","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","test_object_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 100 kHz do 1 GHz Zakres: (0,01-10) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method","methodology_en":"Magnetic field strength: - in the frequency range from 100 kHz to 1 GHz Range: (0,01-10) A/m Direct measurement method Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 100 kHz do 1 GHz Zakres: (0,01-10) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natężenie pola magnetycznego: - w zakresie częstotliwości od 100 kHz do 1 GHz Zakres: (0,01-10) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natezenie pola magnetycznego: - w zakresie czestotliwosci od 100 kHz do 1 GHz Zakres: (0,01-10) A/m Metoda pomiarowa bezposrednia Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Magnetic field strength: - in the frequency range from 100 kHz to 1 GHz Range: (0,01-10) A/m Direct measurement method Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method","search_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban","test_object_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban"},{"_id":"6a5a55f39af9f73f3825153b","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","test_object_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 1 GHz do 18 GHz Zakres: (0,01-0,26) A/m Metoda pomiarowo-obliczeniowa Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method","methodology_en":"Magnetic field strength: - in the frequency range from 1 GHz to 18 GHz Range: (0,01-0,26) A/m Measurement and calculation method Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 1 GHz do 18 GHz Zakres: (0,01-0,26) A/m Metoda pomiarowo-obliczeniowa Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natężenie pola magnetycznego: - w zakresie częstotliwości od 1 GHz do 18 GHz Zakres: (0,01-0,26) A/m Metoda pomiarowo-obliczeniowa Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natezenie pola magnetycznego: - w zakresie czestotliwosci od 1 GHz do 18 GHz Zakres: (0,01-0,26) A/m Metoda pomiarowo-obliczeniowa Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Magnetic field strength: - in the frequency range from 1 GHz to 18 GHz Range: (0,01-0,26) A/m Measurement and calculation method Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method","search_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban","test_object_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban"},{"_id":"6a5a55f39af9f73f3825153c","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements","test_object_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz Zakres: (0,02-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method","methodology_en":"Electric field strength: - in the frequency range from 27 MHz to 6 GHz Range: (0,02-100) V/m Direct measurement method Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz Zakres: (0,02-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method","reference":"enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17","norm_bases":["enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Natężenie pola elektrycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz Zakres: (0,02-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17 Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Natezenie pola elektrycznego: - w zakresie czestotliwosci od 27 MHz do 6 GHz Zakres: (0,02-100) V/m Metoda pomiarowa bezposrednia Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Electric field strength: - in the frequency range from 27 MHz to 6 GHz Range: (0,02-100) V/m Direct measurement method Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17"},{"_id":"6a5a55f39af9f73f3825153d","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements","test_object_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 9 kHz do 250 MHz Zakres: (0,001-0,5) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method","methodology_en":"Magnetic field strength: - in the frequency range from 9 kHz to 250 MHz Range: (0,001-0,5) A/m Direct measurement method Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 9 kHz do 250 MHz Zakres: (0,001-0,5) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Natężenie pola magnetycznego: - w zakresie częstotliwości od 9 kHz do 250 MHz Zakres: (0,001-0,5) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Natezenie pola magnetycznego: - w zakresie czestotliwosci od 9 kHz do 250 MHz Zakres: (0,001-0,5) A/m Metoda pomiarowa bezposrednia Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Magnetic field strength: - in the frequency range from 9 kHz to 250 MHz Range: (0,001-0,5) A/m Direct measurement method Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method"},{"_id":"6a5a55f39af9f73f3825153e","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy Promieniowanie laserowe Work station Laser radiation","test_object_en":"Work station Laser radiation","methodology":"Moc promieniowania laserowego w zakresie spektralnym od 0,19 µm do 11 µm Zakres: (500 ·10-6-10) W Metoda pomiarowa bezpośrednia Energia promieniowania laserowego w zakresie spektralnym od 0,15 µm do 12 µm Zakres: (0,1 ·10-6-1) J Metoda pomiarowa bezpośrednia Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method","methodology_en":"Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc promieniowania laserowego w zakresie spektralnym od 0,19 µm do 11 µm Zakres: (500 ·10-6-10) W Metoda pomiarowa bezpośrednia Energia promieniowania laserowego w zakresie spektralnym od 0,15 µm do 12 µm Zakres: (0,1 ·10-6-1) J Metoda pomiarowa bezpośrednia Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method","reference":"PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01","norm_bases":["PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy Promieniowanie laserowe Work station Laser radiation Moc promieniowania laserowego w zakresie spektralnym od 0,19 µm do 11 µm Zakres: (500 ·10-6-10) W Metoda pomiarowa bezpośrednia Energia promieniowania laserowego w zakresie spektralnym od 0,15 µm do 12 µm Zakres: (0,1 ·10-6-1) J Metoda pomiarowa bezpośrednia Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01 Stanowiska pracy Promieniowanie laserowe Work station Laser radiation Moc promieniowania laserowego w zakresie spektralnym od 0,19 µm do 11 µm Zakres: (500 ·10-6-10) W Metoda pomiarowa bezposrednia Energia promieniowania laserowego w zakresie spektralnym od 0,15 µm do 12 µm Zakres: (0,1 ·10-6-1) J Metoda pomiarowa bezposrednia Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station Laser radiation Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01"},{"_id":"6a5a55f39af9f73f3825153f","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy Oświetlenie elektryczne we wnętrzach Work station Indoor electrical lighting","test_object_en":"Work station Indoor electrical lighting","methodology":"Natężenie oświetlenia w zakresie 20 lx-5000 lx Metoda pomiarowa bezpośrednia Illuminance in the range 20 lx-5000 lx Direct measurement method","methodology_en":"Illuminance in the range 20 lx-5000 lx Direct measurement method Illuminance in the range 20 lx-5000 lx Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia w zakresie 20 lx-5000 lx Metoda pomiarowa bezpośrednia Illuminance in the range 20 lx-5000 lx Direct measurement method","reference":"Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022","norm_bases":["Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy Oświetlenie elektryczne we wnętrzach Work station Indoor electrical lighting Natężenie oświetlenia w zakresie 20 lx-5000 lx Metoda pomiarowa bezpośrednia Illuminance in the range 20 lx-5000 lx Direct measurement method Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022 Stanowiska pracy Oswietlenie elektryczne we wnetrzach Work station Indoor electrical lighting Natezenie oswietlenia w zakresie 20 lx-5000 lx Metoda pomiarowa bezposrednia Illuminance in the range 20 lx-5000 lx Direct measurement method Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station Indoor electrical lighting Illuminance in the range 20 lx-5000 lx Direct measurement method Illuminance in the range 20 lx-5000 lx Direct measurement method Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022"},{"_id":"6a5a55f39af9f73f38251540","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy Oświetlenie elektryczne we wnętrzach Work station Indoor electrical lighting","test_object_en":"Work station Indoor electrical lighting","methodology":"Równomierność oświetlenia na stanowisku pracy (z obliczeń) Uniformity of illumination on work station","methodology_en":"Uniformity of illumination on work station","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia na stanowisku pracy (z obliczeń) Uniformity of illumination on work station","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy Oświetlenie elektryczne we wnętrzach Work station Indoor electrical lighting Równomierność oświetlenia na stanowisku pracy (z obliczeń) Uniformity of illumination on work station Stanowiska pracy Oswietlenie elektryczne we wnetrzach Work station Indoor electrical lighting Rownomiernosc oswietlenia na stanowisku pracy (z obliczen) Uniformity of illumination on work station","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station Indoor electrical lighting Uniformity of illumination on work station"},{"_id":"6a5a55f39af9f73f38251541","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczne natężenie napromienienia promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia. Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm (z obliczeń) Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations)","methodology_en":"Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne natężenie napromienienia promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia. Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm (z obliczeń) Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations)","reference":"PN-EN 14255-2:2010 Metoda O Method O","norm_bases":["PN-EN 14255-2:2010 Metoda O Method O"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natężenie napromienienia promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia. Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm (z obliczeń) Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations) PN-EN 14255-2:2010 Metoda O Method O Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natezenie napromienienia promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Metoda pomiarowa bezposrednia. Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm (z obliczen) Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations) PN-EN 14255-2:2010 Metoda O Method O","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations) PN-EN 14255-2:2010 Metoda O Method O","search_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation PN-EN 14255-2:2010 Metoda O Method O","test_object_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation"},{"_id":"6a5a55f39af9f73f38251542","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Metoda pomiarowa bezpośrednia Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method","methodology_en":"Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Metoda pomiarowa bezpośrednia Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method","reference":"PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R","norm_bases":["PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Metoda pomiarowa bezpośrednia Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Metoda pomiarowa bezposrednia Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R","search_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R","test_object_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation"},{"_id":"6a5a55f39af9f73f38251543","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Natężenie napromienienia promieniowania nadfioletowego, widzialnego i podczerwonego w zakresie spektralnym od 200 nm do 40 000 nm Zakres: (0,2-2,22 103) W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym, widzialnym i podczerwonym w zakresie spektralnym od 200 nm do 40000 nm (z obliczeń) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)","methodology_en":"Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Radiant exposure to ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40000 nm (calculated) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie napromienienia promieniowania nadfioletowego, widzialnego i podczerwonego w zakresie spektralnym od 200 nm do 40 000 nm Zakres: (0,2-2,22 103) W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym, widzialnym i podczerwonym w zakresie spektralnym od 200 nm do 40000 nm (z obliczeń) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natężenie napromienienia promieniowania nadfioletowego, widzialnego i podczerwonego w zakresie spektralnym od 200 nm do 40 000 nm Zakres: (0,2-2,22 103) W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym, widzialnym i podczerwonym w zakresie spektralnym od 200 nm do 40000 nm (z obliczeń) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations) Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natezenie napromienienia promieniowania nadfioletowego, widzialnego i podczerwonego w zakresie spektralnym od 200 nm do 40 000 nm Zakres: (0,2-2,22 103) W/m2 Metoda pomiarowa bezposrednia Napromienienie promieniowaniem nadfioletowym, widzialnym i podczerwonym w zakresie spektralnym od 200 nm do 40000 nm (z obliczen) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Radiant exposure to ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40000 nm (calculated) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)","search_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation","test_object_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation"},{"_id":"6a5a55f39af9f73f38251544","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Natężenie napromienienia bliską i średnią podczerwienią w zakresie spektralnym od 770 nm do 3 000 nm. Zakres: (0,857-9,52 ∙ 103)W/m2. Metoda pomiarowa bezpośrednia Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method","methodology_en":"Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie napromienienia bliską i średnią podczerwienią w zakresie spektralnym od 770 nm do 3 000 nm. Zakres: (0,857-9,52 ∙ 103)W/m2. Metoda pomiarowa bezpośrednia Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natężenie napromienienia bliską i średnią podczerwienią w zakresie spektralnym od 770 nm do 3 000 nm. Zakres: (0,857-9,52 ∙ 103)W/m2. Metoda pomiarowa bezpośrednia Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natezenie napromienienia bliska i srednia podczerwienia w zakresie spektralnym od 770 nm do 3 000 nm. Zakres: (0,857-9,52 ∙ 103)W/m2. Metoda pomiarowa bezposrednia Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method","search_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation","test_object_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation"},{"_id":"6a5a55f39af9f73f38251545","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczna luminancja energetyczna źródła promieniowania widzialnego i bliskiej podczerwieni w zakresie spektralnym od 305 do 1400 nm Metoda pomiarowa i obliczeniowa Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method","methodology_en":"Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna luminancja energetyczna źródła promieniowania widzialnego i bliskiej podczerwieni w zakresie spektralnym od 305 do 1400 nm Metoda pomiarowa i obliczeniowa Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method","reference":"PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r.","norm_bases":["PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna źródła promieniowania widzialnego i bliskiej podczerwieni w zakresie spektralnym od 305 do 1400 nm Metoda pomiarowa i obliczeniowa Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r. Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna zrodla promieniowania widzialnego i bliskiej podczerwieni w zakresie spektralnym od 305 do 1400 nm Metoda pomiarowa i obliczeniowa Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r.","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r.","search_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r.","test_object_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation"},{"_id":"6a5a55f39af9f73f38251546","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczne natężenie napromienienia bliską podczerwienią w zakresie spektralnym od 770 nm do 1400 nm Zakres: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Metoda pomiarowa bezpośrednia Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method","methodology_en":"Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne natężenie napromienienia bliską podczerwienią w zakresie spektralnym od 770 nm do 1400 nm Zakres: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Metoda pomiarowa bezpośrednia Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method","reference":"PN-T 05687:2002","norm_bases":["PN-T 05687:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natężenie napromienienia bliską podczerwienią w zakresie spektralnym od 770 nm do 1400 nm Zakres: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Metoda pomiarowa bezpośrednia Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method PN-T 05687:2002 Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natezenie napromienienia bliska podczerwienia w zakresie spektralnym od 770 nm do 1400 nm Zakres: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Metoda pomiarowa bezposrednia Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method PN-T 05687:2002","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method PN-T 05687:2002","search_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation PN-T 05687:2002","test_object_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation"},{"_id":"6a5a55f39af9f73f38251547","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczna luminancja energetyczna w zakresie spektralnym od 770 nm do 1400 nm (z obliczeń) Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)","methodology_en":"Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna luminancja energetyczna w zakresie spektralnym od 770 nm do 1400 nm (z obliczeń) Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna w zakresie spektralnym od 770 nm do 1400 nm (z obliczeń) Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations) Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna w zakresie spektralnym od 770 nm do 1400 nm (z obliczen) Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)","search_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation","test_object_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation"},{"_id":"6a5a55f39af9f73f38251548","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczne natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 235 nm do 307 nm. Zakres: (5 ∙ 10-5-25) W/m2 Metoda pomiarowa bezpośrednia Skuteczne napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 235 nm do 307 nm (z obliczeń) Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations)","methodology_en":"Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 235 nm do 307 nm. Zakres: (5 ∙ 10-5-25) W/m2 Metoda pomiarowa bezpośrednia Skuteczne napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 235 nm do 307 nm (z obliczeń) Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations)","reference":"PN-EN 14255-1:2010 Metoda A Method A","norm_bases":["PN-EN 14255-1:2010 Metoda A Method A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 235 nm do 307 nm. Zakres: (5 ∙ 10-5-25) W/m2 Metoda pomiarowa bezpośrednia Skuteczne napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 235 nm do 307 nm (z obliczeń) Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations) PN-EN 14255-1:2010 Metoda A Method A Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natezenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 235 nm do 307 nm. Zakres: (5 ∙ 10-5-25) W/m2 Metoda pomiarowa bezposrednia Skuteczne napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 235 nm do 307 nm (z obliczen) Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations) PN-EN 14255-1:2010 Metoda A Method A","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations) PN-EN 14255-1:2010 Metoda A Method A","search_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation PN-EN 14255-1:2010 Metoda A Method A","test_object_zh":"工作环境 － 非激光光辐射 Working environment Non-laser optical radiation"},{"_id":"6a5a55f39af9f73f38251549","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy Nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 315 nm do 390 nm. Zakres: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 315 nm do 390 nm (z obliczeń) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations)","methodology_en":"Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Radiant exposure to ultraviolet radiation in the spectral range from 315 nm to 390 nm (calculated) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 315 nm do 390 nm. Zakres: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 315 nm do 390 nm (z obliczeń) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations)","reference":"PN-EN 14255-1:2010 Metoda M Method M","norm_bases":["PN-EN 14255-1:2010 Metoda M Method M"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy Nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 315 nm do 390 nm. Zakres: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 315 nm do 390 nm (z obliczeń) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations) PN-EN 14255-1:2010 Metoda M Method M Srodowisko pracy Nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natezenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 315 nm do 390 nm. Zakres: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Metoda pomiarowa bezposrednia Napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 315 nm do 390 nm (z obliczen) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations) PN-EN 14255-1:2010 Metoda M Method M","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Radiant exposure to ultraviolet radiation in the spectral range from 315 nm to 390 nm (calculated) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations) PN-EN 14255-1:2010 Metoda M Method M"},{"_id":"6a5a55f39af9f73f3825154a","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry Working environment- - air samples collected on filters","test_object_en":"Working environment- - air samples collected on filters","methodology":"Zawartość spalin emitowanych z silników Diesla mierzonych jako węgiel elementarny (EC) Zakres: (0,46 – 73,6) μg/cm2 Metoda termiczno-optyczna z detekcją płomieniowo-jonizacyjną (TOA-FID) Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection","methodology_en":"Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość spalin emitowanych z silników Diesla mierzonych jako węgiel elementarny (EC) Zakres: (0,46 – 73,6) μg/cm2 Metoda termiczno-optyczna z detekcją płomieniowo-jonizacyjną (TOA-FID) Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection","reference":"Podstawy i Metody Oceny Środowiska Pracy 2023, nr 1(115) s.5-25","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2023, nr 1(115) s.5-25"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Working environment- - air samples collected on filters Zawartość spalin emitowanych z silników Diesla mierzonych jako węgiel elementarny (EC) Zakres: (0,46 – 73,6) μg/cm2 Metoda termiczno-optyczna z detekcją płomieniowo-jonizacyjną (TOA-FID) Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection Podstawy i Metody Oceny Środowiska Pracy 2023, nr 1(115) s.5-25 Srodowisko pracy - probki powietrza pobrane na filtry Working environment- - air samples collected on filters Zawartosc spalin emitowanych z silnikow Diesla mierzonych jako wegiel elementarny (EC) Zakres: (0,46 – 73,6) μg/cm2 Metoda termiczno-optyczna z detekcja plomieniowo-jonizacyjna (TOA-FID) Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection Podstawy i Metody Oceny Srodowiska Pracy 2023, nr 1(115) s.5-25","categories":["environment","petro"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment- - air samples collected on filters Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection Podstawy i Metody Oceny Środowiska Pracy 2023, nr 1(115) s.5-25"},{"_id":"6a5a55f39af9f73f3825154b","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy Wydatek energetyczny Working environment Energy expenditure","test_object_en":"Working environment Energy expenditure","methodology":"Temperatura powietrza Zakres: (5-35) °C Przepływ powietrza Zakres: (10-60) dm3/min Metoda pomiarowa bezpośrednia Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method","methodology_en":"Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (5-35) °C Przepływ powietrza Zakres: (10-60) dm3/min Metoda pomiarowa bezpośrednia Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method","reference":"NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023","norm_bases":["NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy Wydatek energetyczny Working environment Energy expenditure Temperatura powietrza Zakres: (5-35) °C Przepływ powietrza Zakres: (10-60) dm3/min Metoda pomiarowa bezpośrednia Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023 Srodowisko pracy Wydatek energetyczny Working environment Energy expenditure Temperatura powietrza Zakres: (5-35) °C Przeplyw powietrza Zakres: (10-60) dm3/min Metoda pomiarowa bezposrednia Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Energy expenditure Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023"},{"_id":"6a5a55f39af9f73f3825154c","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy Wydatek energetyczny Working environment Energy expenditure","test_object_en":"Working environment Energy expenditure","methodology":"Wydatek energetyczny (z obliczeń) Energy expenditure (from calculation)","methodology_en":"Energy expenditure (from calculation)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydatek energetyczny (z obliczeń) Energy expenditure (from calculation)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy Wydatek energetyczny Working environment Energy expenditure Wydatek energetyczny (z obliczeń) Energy expenditure (from calculation) Srodowisko pracy Wydatek energetyczny Working environment Energy expenditure Wydatek energetyczny (z obliczen) Energy expenditure (from calculation)","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Energy expenditure Energy expenditure (from calculation)"},{"_id":"6a5a55f39af9f73f3825154d","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Badania eksploatacyjne Practical performance","methodology_en":"Practical performance testing Practical performance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania eksploatacyjne Practical performance","reference":"EN 14593-1:2018 EN 13274-2:2019","norm_bases":["EN 14593-1:2018 EN 13274-2:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Badania eksploatacyjne Practical performance EN 14593-1:2018 EN 13274-2:2019 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Badania eksploatacyjne Practical performance EN 14593-1:2018 EN 13274-2:2019","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Practical performance testing Practical performance EN 14593-1:2018 EN 13274-2:2019","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask 运行使用检验 Practical performance EN 14593-1:2018 EN 13274-2:2019","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask","methodology_zh":"运行使用检验 Practical performance"},{"_id":"6a5a55f39af9f73f3825154e","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Wytrzymałość połączeń Strength of connections","methodology_en":"Strength of connections","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość połączeń Strength of connections","reference":"EN 14593-1:2018","norm_bases":["EN 14593-1:2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Wytrzymałość połączeń Strength of connections EN 14593-1:2018 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Wytrzymalosc polaczen Strength of connections EN 14593-1:2018","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Strength of connections EN 14593-1:2018","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask 连接强度 Strength of connections EN 14593-1:2018","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask","methodology_zh":"连接强度 Strength of connections"},{"_id":"6a5a55f39af9f73f3825154f","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Palność Flammability","methodology_en":"Flammability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Palność Flammability","reference":"EN 14593-1:2018 EN 13274-4:2020","norm_bases":["EN 14593-1:2018 EN 13274-4:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Palność Flammability EN 14593-1:2018 EN 13274-4:2020 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Palnosc Flammability EN 14593-1:2018 EN 13274-4:2020","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Flammability EN 14593-1:2018 EN 13274-4:2020","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask 可燃性 Flammability EN 14593-1:2018 EN 13274-4:2020","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask","methodology_zh":"可燃性 Flammability"},{"_id":"6a5a55f39af9f73f38251550","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Przeciek wewnętrzny Inward leakage","methodology_en":"Inward leakage Inward leakage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przeciek wewnętrzny Inward leakage","reference":"EN 14593-1:2018 EN 13274-1:2001","norm_bases":["EN 14593-1:2018 EN 13274-1:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Przeciek wewnętrzny Inward leakage EN 14593-1:2018 EN 13274-1:2001 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Przeciek wewnetrzny Inward leakage EN 14593-1:2018 EN 13274-1:2001","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Inward leakage Inward leakage EN 14593-1:2018 EN 13274-1:2001","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask EN 14593-1:2018 EN 13274-1:2001","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask"},{"_id":"6a5a55f39af9f73f38251551","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Opór oddychania Breathing resistance","methodology_en":"Breathing resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór oddychania Breathing resistance","reference":"EN 14593-1:2018 EN 13274-3:2001","norm_bases":["EN 14593-1:2018 EN 13274-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Opór oddychania Breathing resistance EN 14593-1:2018 EN 13274-3:2001 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Opor oddychania Breathing resistance EN 14593-1:2018 EN 13274-3:2001","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Breathing resistance EN 14593-1:2018 EN 13274-3:2001","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask 呼吸阻力 Breathing resistance EN 14593-1:2018 EN 13274-3:2001","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask","methodology_zh":"呼吸阻力 Breathing resistance"},{"_id":"6a5a55f39af9f73f38251552","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air","methodology_en":"Carbon dioxide content of the inhalation air Carbon dioxide content of the inhalation air","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air","reference":"EN 14593-1:2018 EN 13274-6:2001","norm_bases":["EN 14593-1:2018 EN 13274-6:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air EN 14593-1:2018 EN 13274-6:2001 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Zawartosc dwutlenku wegla w powietrzu wdychanym Carbon dioxide content of the inhalation air EN 14593-1:2018 EN 13274-6:2001","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Carbon dioxide content of the inhalation air Carbon dioxide content of the inhalation air EN 14593-1:2018 EN 13274-6:2001","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask EN 14593-1:2018 EN 13274-6:2001","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask"},{"_id":"6a5a55f39af9f73f38251553","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Odporność termiczna Resistance to temperature","methodology_en":"Resistance to temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność termiczna Resistance to temperature","reference":"EN 14593-2:2005","norm_bases":["EN 14593-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Odporność termiczna Resistance to temperature EN 14593-2:2005 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Odpornosc termiczna Resistance to temperature EN 14593-2:2005","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Resistance to temperature EN 14593-2:2005","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask 耐温度性 Resistance to temperature EN 14593-2:2005","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 Compressed air line breathing devices with demand valve Devices with a full face mask","methodology_zh":"耐温度性 Resistance to temperature"},{"_id":"6a5a55f39af9f73f38251554","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Badania eksploatacyjne Practical performance","methodology_en":"Practical performance testing Practical performance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania eksploatacyjne Practical performance","reference":"EN 14593-2:2005 EN 13274-2:2019","norm_bases":["EN 14593-2:2005 EN 13274-2:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Badania eksploatacyjne Practical performance EN 14593-2:2005 EN 13274-2:2019 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Badania eksploatacyjne Practical performance EN 14593-2:2005 EN 13274-2:2019","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Practical performance testing Practical performance EN 14593-2:2005 EN 13274-2:2019","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure 运行使用检验 Practical performance EN 14593-2:2005 EN 13274-2:2019","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology_zh":"运行使用检验 Practical performance"},{"_id":"6a5a55f39af9f73f38251555","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Wytrzymałość połączeń Strength of connections","methodology_en":"Strength of connections","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość połączeń Strength of connections","reference":"EN 14593-2:2005","norm_bases":["EN 14593-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Wytrzymałość połączeń Strength of connections EN 14593-2:2005 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Wytrzymalosc polaczen Strength of connections EN 14593-2:2005","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Strength of connections EN 14593-2:2005","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure 连接强度 Strength of connections EN 14593-2:2005","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology_zh":"连接强度 Strength of connections"},{"_id":"6a5a55f39af9f73f38251556","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Palność Flammability","methodology_en":"Flammability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Palność Flammability","reference":"EN 14593-2:2005 EN 13274-4:2020","norm_bases":["EN 14593-2:2005 EN 13274-4:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Palność Flammability EN 14593-2:2005 EN 13274-4:2020 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Palnosc Flammability EN 14593-2:2005 EN 13274-4:2020","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Flammability EN 14593-2:2005 EN 13274-4:2020","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure 可燃性 Flammability EN 14593-2:2005 EN 13274-4:2020","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology_zh":"可燃性 Flammability"},{"_id":"6a5a55f39af9f73f38251557","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Przeciek wewnętrzny Inward leakage","methodology_en":"Inward leakage Inward leakage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przeciek wewnętrzny Inward leakage","reference":"EN 14593-2:2005 EN 13274-1:2001","norm_bases":["EN 14593-2:2005 EN 13274-1:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Przeciek wewnętrzny Inward leakage EN 14593-2:2005 EN 13274-1:2001 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Przeciek wewnetrzny Inward leakage EN 14593-2:2005 EN 13274-1:2001","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Inward leakage Inward leakage EN 14593-2:2005 EN 13274-1:2001","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure EN 14593-2:2005 EN 13274-1:2001","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure"},{"_id":"6a5a55f39af9f73f38251558","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Opór oddychania Breathing resistance","methodology_en":"Breathing resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór oddychania Breathing resistance","reference":"EN 14593-2:2005 EN 13274-3:2001","norm_bases":["EN 14593-2:2005 EN 13274-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Opór oddychania Breathing resistance EN 14593-2:2005 EN 13274-3:2001 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Opor oddychania Breathing resistance EN 14593-2:2005 EN 13274-3:2001","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Breathing resistance EN 14593-2:2005 EN 13274-3:2001","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure 呼吸阻力 Breathing resistance EN 14593-2:2005 EN 13274-3:2001","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology_zh":"呼吸阻力 Breathing resistance"},{"_id":"6a5a55f39af9f73f38251559","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air","methodology_en":"Carbon dioxide content of the inhalation air Carbon dioxide content of the inhalation air","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air","reference":"EN 14593-2:2005","norm_bases":["EN 14593-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air EN 14593-2:2005 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Zawartosc dwutlenku wegla w powietrzu wdychanym Carbon dioxide content of the inhalation air EN 14593-2:2005","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Carbon dioxide content of the inhalation air Carbon dioxide content of the inhalation air EN 14593-2:2005","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure EN 14593-2:2005","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure"},{"_id":"6a5a55f39af9f73f3825155a","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Odporność termiczna Resistance to temperature","methodology_en":"Resistance to temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność termiczna Resistance to temperature","reference":"EN 14593-2:2005","norm_bases":["EN 14593-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Odporność termiczna Resistance to temperature EN 14593-2:2005 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Odpornosc termiczna Resistance to temperature EN 14593-2:2005","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Resistance to temperature EN 14593-2:2005","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure 耐温度性 Resistance to temperature EN 14593-2:2005","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology_zh":"耐温度性 Resistance to temperature"},{"_id":"6a5a55f39af9f73f3825155b","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Masa Mass","methodology_en":"Mass","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa Mass","reference":"EN 14435:2004","norm_bases":["EN 14435:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Masa Mass EN 14435:2004 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Masa Mass EN 14435:2004","categories":["environment"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Mass EN 14435:2004","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only EN 14435:2004","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only"},{"_id":"6a5a55f39af9f73f3825155c","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Odporność termiczna Resistance to temperature","methodology_en":"Resistance to temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność termiczna Resistance to temperature","reference":"EN 14435:2004 EN 13274-5:2001","norm_bases":["EN 14435:2004 EN 13274-5:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Odporność termiczna Resistance to temperature EN 14435:2004 EN 13274-5:2001 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Odpornosc termiczna Resistance to temperature EN 14435:2004 EN 13274-5:2001","categories":["environment"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Resistance to temperature EN 14435:2004 EN 13274-5:2001","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only 耐温度性 Resistance to temperature EN 14435:2004 EN 13274-5:2001","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology_zh":"耐温度性 Resistance to temperature"},{"_id":"6a5a55f39af9f73f3825155d","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Wytrzymałość połączeń Strength of connections","methodology_en":"Strength of connections","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość połączeń Strength of connections","reference":"EN 14435:2004","norm_bases":["EN 14435:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Wytrzymałość połączeń Strength of connections EN 14435:2004 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Wytrzymalosc polaczen Strength of connections EN 14435:2004","categories":["environment"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Strength of connections EN 14435:2004","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only 连接强度 Strength of connections EN 14435:2004","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology_zh":"连接强度 Strength of connections"},{"_id":"6a5a55f39af9f73f3825155e","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Badania eksploatacyjne Practical performance","methodology_en":"Practical performance testing Practical performance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania eksploatacyjne Practical performance","reference":"EN 14435:2004 EN 13274-2:2019","norm_bases":["EN 14435:2004 EN 13274-2:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Badania eksploatacyjne Practical performance EN 14435:2004 EN 13274-2:2019 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Badania eksploatacyjne Practical performance EN 14435:2004 EN 13274-2:2019","categories":["environment"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Practical performance testing Practical performance EN 14435:2004 EN 13274-2:2019","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only 运行使用检验 Practical performance EN 14435:2004 EN 13274-2:2019","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology_zh":"运行使用检验 Practical performance"},{"_id":"6a5a55f39af9f73f3825155f","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Palność Flammability","methodology_en":"Flammability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Palność Flammability","reference":"EN 14435:2004 EN 13274-4:2020","norm_bases":["EN 14435:2004 EN 13274-4:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Palność Flammability EN 14435:2004 EN 13274-4:2020 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Palnosc Flammability EN 14435:2004 EN 13274-4:2020","categories":["environment"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Flammability EN 14435:2004 EN 13274-4:2020","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only 可燃性 Flammability EN 14435:2004 EN 13274-4:2020","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology_zh":"可燃性 Flammability"},{"_id":"6a5a55f39af9f73f38251560","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Opór oddychania Breathing resistance","methodology_en":"Breathing resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór oddychania Breathing resistance","reference":"EN 14435:2004 EN 13274-3:2001","norm_bases":["EN 14435:2004 EN 13274-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Opór oddychania Breathing resistance EN 14435:2004 EN 13274-3:2001 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Opor oddychania Breathing resistance EN 14435:2004 EN 13274-3:2001","categories":["environment"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Breathing resistance EN 14435:2004 EN 13274-3:2001","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only 呼吸阻力 Breathing resistance EN 14435:2004 EN 13274-3:2001","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology_zh":"呼吸阻力 Breathing resistance"}],"has_pdf":true}