{"lab":{"_id":"69ad52a3de79e566650fb0db","accr_number":"AB 038","country":"PL","accr_body":"PCA","address":"- PAŃSTWOWY INSTYTUT BADAWCZY, ul. Czerniakowska 16, 00-701 Warszawa","categories":["environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":43,"name":"CENTRALNY INSTYTUT OCHRONY PRACY","parse_status":"parsed","parse_version":3,"pdf_files":["AB_038.pdf"],"scope_summary":"","search_text":"centralny instytut ochrony pracy - państwowy instytut badawczy, ul. czerniakowska 16, 00-701 warszawa other environment metrology pharma electronics materials construction automotive food water petro","status":"active","updated_at":"2026-03-08T14:50:04.628Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:04.628Z","parse_date":"2026-07-17T16:18:58.996Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://www.ciop.pl/CIOPPortalWAR/appmanager/ciop/pl (Kontakt)","fields_of_testing":[{"codes":"A/19","pl":"Badania akustyczne i drgań środków ochrony osobistej","en":"Acoustic and vibration tests of personal protection equipment","de":"Akustische und Schwingungsprüfungen persönlicher Schutzausrüstung","zh":"个人防护装备的声学和振动检测","cs":"Akustické a vibrační zkoušky osobních ochranných prostředků"},{"codes":"A/33","pl":"Badania akustyczne i drgań-środowisko pracy (czynniki szkodliwe –hałas)","en":"Acoustic and vibration tests of workplace (harmful factors – noise )","de":"Akustische und Schwingungsprüfungen – Arbeitsumgebung (Schadfaktoren – Lärm)","zh":"声学和振动检测——工作环境（有害因素——噪声）","cs":"Akustické a vibrační zkoušky-pracovní prostředí (škodlivé faktory –hluk)"},{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests – working envronment (harmful factors – air)","de":"Chemische Prüfungen – Arbeitsumgebung (Schadfaktoren – Luft)","zh":"化学检测——工作环境（有害因素——空气）","cs":"Chemické zkoušky – pracovní prostředí (škodlivé faktory – ovzduší)"},{"codes":"E/19","pl":"Badania elektryczne środków ochrony osobistej","en":"Electric tests of electrical products and equipment and personal protection equipment","de":"Elektrische Prüfungen persönlicher Schutzausrüstung","zh":"个人防护装备的电气检测","cs":"Elektrické zkoušky osobních ochranných prostředků"},{"codes":"G/33; G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne)-środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, pole elektromagnetyczne, oświetlenie, wydatek energetyczny, promieniowanie optyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment , (harmful and nuisance factors – noise, vibration, electromagnetic field, lighting, energy expenditure, optical radiation )","de":"Prüfungen der Umwelttechnik (Umwelt- und Klimaprüfungen) – Arbeitsumgebung (Schad- und Belastungsfaktoren – Lärm, Vibrationen, elektromagnetisches Feld, Beleuchtung, Energieumsatz, optische Strahlung)","zh":"环境工程检测（环境和气候）——工作环境（有害和不适因素——噪声、振动、电磁场、照明、能量消耗、光辐射）","cs":"Zkoušky v oblasti environmentálního inženýrství (environmentální a klimatické)-pracovní prostředí (škodlivé a obtěžující faktory – hluk, vibrace, elektromagnetické pole, osvětlení, energetický výdej, optické záření)"},{"codes":"H/19","pl":"Badania ogniowe środków ochrony osobistej","en":"Fire tests of personal protection equipment","de":"Brandprüfungen persönlicher Schutzausrüstung","zh":"个人防护装备的防火检测","cs":"Požární zkoušky osobních ochranných prostředků"},{"codes":"J/13; J/17; J/19","pl":"Badania mechaniczne maszyn, wyrobów innych i środków ochrony osobistej","en":"Mechanical tests of electrical products and equipment, machinery, other products and personal protection equipment","de":"Mechanische Prüfungen von Maschinen, sonstigen Erzeugnissen und persönlicher Schutzausrüstung","zh":"机器、其他产品和个人防护装备的力学检测","cs":"Mechanické zkoušky strojů, ostatních výrobků a osobních ochranných prostředků"},{"codes":"N/13; N/19","pl":"Badania właściwości fizycznych maszyn, środków ochrony osobistej","en":"Tests of physical properties of machinery, personal protection equipment","de":"Prüfungen physikalischer Eigenschaften von Maschinen, persönlicher Schutzausrüstung","zh":"机器、个人防护装备的物理性能检测","cs":"Zkoušky fyzikálních vlastností strojů, osobních ochranných prostředků"}],"issue":{"no":"27","date":"22.07.2025"},"map_coord":[52.199756,21.051208],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":26,"other":17,"petro":1},"category_scores":{"environment":15.36,"other":6.57,"petro":0.02},"has_zh":true,"has_de":true,"has_cs":true,"pelny_cs":true},"methods":[{"_id":"6a5a55f39af9f73f38251536","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy − hałas Work station – noise","test_object_en":"Work station – noise","methodology":"Równoważny poziom dźwięku A Zakres: (40 -136) dB Maksymalny poziom dźwięku A Zakres: (40 -136) dB Szczytowy poziom dźwięku C Zakres: (40 -138) dB Metoda pomiarowa bezpośrednia A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method","methodology_en":"A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (40 -136) dB Maksymalny poziom dźwięku A Zakres: (40 -136) dB Szczytowy poziom dźwięku C Zakres: (40 -138) dB Metoda pomiarowa bezpośrednia A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method","reference":"PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11","norm_bases":["PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy − hałas Work station – noise Równoważny poziom dźwięku A Zakres: (40 -136) dB Maksymalny poziom dźwięku A Zakres: (40 -136) dB Szczytowy poziom dźwięku C Zakres: (40 -138) dB Metoda pomiarowa bezpośrednia A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11 Stanowiska pracy − halas Work station – noise Rownowazny poziom dzwieku A Zakres: (40 -136) dB Maksymalny poziom dzwieku A Zakres: (40 -136) dB Szczytowy poziom dzwieku C Zakres: (40 -138) dB Metoda pomiarowa bezposrednia A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 3 – punkt 11 with the exception of the method including Strategy 3-Clause 11","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station – noise A-weighted equivalent sound pressure level Range: (40 -136) dB A-weighted maximum sound pressure level Range: (40 - 136) dB C-weighted peak sound pressure level Range: (40 -138) dB Direct measurement method PN-N-01307:1994; PN-EN ISO 9612:2011 with the exception of the method including Strategy 3 – Clause 11","methodology_de":"A-bewerteter äquivalenter Dauerschallpegel Bereich: (40 -136) dB Maximaler A-bewerteter Schallpegel Bereich: (40 -136) dB C-bewerteter Spitzenschalldruckpegel Bereich: (40 -138) dB Direktes Messverfahren","search_de":"Arbeitsplätze − Lärm A-bewerteter äquivalenter Dauerschallpegel Bereich: (40 -136) dB Maximaler A-bewerteter Schallpegel Bereich: (40 -136) dB C-bewerteter Spitzenschalldruckpegel Bereich: (40 -138) dB Direktes Messverfahren PN-N-01307:1994; PN-EN ISO 9612:2011 ausgenommen das Verfahren mit Strategie 3 – Abschnitt 11","test_object_de":"Arbeitsplätze − Lärm","methodology_zh":"A 计权等效声级 范围： (40 -136) dB A 计权最大声级 范围： (40 -136) dB C 计权峰值声级 范围： (40 -138) dB 直接测量法","search_zh":"工作岗位 − 噪声 A 计权等效声级 范围： (40 -136) dB A 计权最大声级 范围： (40 -136) dB C 计权峰值声级 范围： (40 -138) dB 直接测量法 PN-N-01307:1994；PN-EN ISO 9612:2011 不含涉及策略3的方法 – 第11条","test_object_zh":"工作岗位 − 噪声","reference_en":"PN-N-01307:1994; PN-EN ISO 9612:2011 with the exception of the method including Strategy 3 – Clause 11","reference_de":"PN-N-01307:1994; PN-EN ISO 9612:2011 ausgenommen das Verfahren mit Strategie 3 – Abschnitt 11","reference_zh":"PN-N-01307:1994；PN-EN ISO 9612:2011 不含涉及策略3的方法 – 第11条","methodology_cs":"Ekvivalentní hladina akustického tlaku A Rozsah: (40 -136) dB Maximální hladina akustického tlaku A Rozsah: (40 -136) dB Špičková hladina akustického tlaku C Rozsah: (40 -138) dB Přímá měřicí metoda","reference_cs":"PN-N-01307:1994 PN-EN ISO 9612:2011 mimo metodu zahrnující strategii 3 – čl. 11","search_cs":"Pracovní místa − hluk Ekvivalentní hladina akustického tlaku A Rozsah: (40 -136) dB Maximální hladina akustického tlaku A Rozsah: (40 -136) dB Špičková hladina akustického tlaku C Rozsah: (40 -138) dB Přímá měřicí metoda PN-N-01307:1994 PN-EN ISO 9612:2011 mimo metodu zahrnující strategii 3 – čl. 11","test_object_cs":"Pracovní místa − hluk"},{"_id":"6a5a55f39af9f73f38251537","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy − hałas Work station – noise","test_object_en":"Work station – noise","methodology":"Poziom ekspozycji na hałas odniesiony do:  8-godz. Dobowego wymiaru czasu pracy  przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)","methodology_en":"Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do:  8-godz. Dobowego wymiaru czasu pracy  przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy − hałas Work station – noise Poziom ekspozycji na hałas odniesiony do:  8-godz. Dobowego wymiaru czasu pracy  przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations) Stanowiska pracy − halas Work station – noise Poziom ekspozycji na halas odniesiony do:  8-godz. Dobowego wymiaru czasu pracy  przecietnego tygodniowego wymiaru czasu pracy (z obliczen) Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station – noise Noise exposure level normalized to: – an 8 h working day – an average weekly working time (from calculations)","methodology_de":"Lärmexpositionspegel bezogen auf:  die 8-stündige tägliche Arbeitszeit  die durchschnittliche wöchentliche Arbeitszeit (berechnet)","search_de":"Arbeitsplätze − Lärm Lärmexpositionspegel bezogen auf:  die 8-stündige tägliche Arbeitszeit  die durchschnittliche wöchentliche Arbeitszeit (berechnet)","test_object_de":"Arbeitsplätze − Lärm","methodology_zh":"噪声暴露级，基准为：  8 小时每日工作时间  平均每周工作时间 （计算得出）","search_zh":"工作岗位 − 噪声 噪声暴露级，基准为：  8 小时每日工作时间  平均每周工作时间 （计算得出）","test_object_zh":"工作岗位 − 噪声","methodology_cs":"Hladina expozice hluku vztažená k:  8hod. dennímu pracovnímu času  průměrné týdenní pracovní době (výpočtem)","search_cs":"Pracovní místa − hluk Hladina expozice hluku vztažená k:  8hod. dennímu pracovnímu času  průměrné týdenní pracovní době (výpočtem)","test_object_cs":"Pracovní místa − hluk"},{"_id":"6a5a55f39af9f73f38251538","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy − hałas ultradźwiękowy Work station – ultrasonic noise","test_object_en":"Work station – ultrasonic noise","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Metoda pomiarowa bezpośrednia Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method","methodology_en":"Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Metoda pomiarowa bezpośrednia Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method","reference":"PN-Z-01339:2020","norm_bases":["PN-Z-01339:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy − hałas ultradźwiękowy Work station – ultrasonic noise Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Metoda pomiarowa bezpośrednia Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method PN-Z-01339:2020 Stanowiska pracy − halas ultradzwiekowy Work station – ultrasonic noise Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Maksymalny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Zakres: (50-136) dB Metoda pomiarowa bezposrednia Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method PN-Z-01339:2020","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Maximum sound pressure level in third octave bands with the center frequencies from 10 kHz to 40 kHz Range: (50-136) dB Direct measurement method PN-Z-01339:2020","methodology_de":"Äquivalente Schalldruckpegel in Terzbändern mit Mittenfrequenzen von 10 kHz bis 40 kHz Bereich: (50-136) dB Maximaler Schalldruckpegel in Terzbändern mit Mittenfrequenzen von 10 kHz bis 40 kHz Bereich: (50-136) dB Direktes Messverfahren","search_de":"Arbeitsplätze − Ultraschalllärm Äquivalente Schalldruckpegel in Terzbändern mit Mittenfrequenzen von 10 kHz bis 40 kHz Bereich: (50-136) dB Maximaler Schalldruckpegel in Terzbändern mit Mittenfrequenzen von 10 kHz bis 40 kHz Bereich: (50-136) dB Direktes Messverfahren PN-Z-01339:2020","test_object_de":"Arbeitsplätze − Ultraschalllärm","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的三分之一倍频程等效声压级 范围：(50-136) dB 中心频率自 10 kHz 至 40 kHz 的三分之一倍频程最大声压级 范围：(50-136) dB 直接测量法","search_zh":"工作岗位 − 超声噪声 中心频率自 10 kHz 至 40 kHz 的三分之一倍频程等效声压级 范围：(50-136) dB 中心频率自 10 kHz 至 40 kHz 的三分之一倍频程最大声压级 范围：(50-136) dB 直接测量法 PN-Z-01339:2020","test_object_zh":"工作岗位 − 超声噪声","methodology_cs":"Ekvivalentní hladiny akustického tlaku v třetinooktávových pásmech se středními kmitočty od 10 kHz do 40 kHz Rozsah: (50-136) dB Maximální hladina akustického tlaku v třetinooktávových pásmech se středními kmitočty od 10 kHz do 40 kHz Rozsah: (50-136) dB Přímá měřicí metoda","search_cs":"Pracovní místa − ultrazvukový hluk Ekvivalentní hladiny akustického tlaku v třetinooktávových pásmech se středními kmitočty od 10 kHz do 40 kHz Rozsah: (50-136) dB Maximální hladina akustického tlaku v třetinooktávových pásmech se středními kmitočty od 10 kHz do 40 kHz Rozsah: (50-136) dB Přímá měřicí metoda PN-Z-01339:2020","test_object_cs":"Pracovní místa − ultrazvukový hluk"},{"_id":"6a5a55f39af9f73f38251539","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","test_object_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 18 GHz Zakres: (0,6-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method","methodology_en":"Electric field strength: - in the frequency range from 100 kHz to 18 GHz Range: (0,6-100) V/m Direct measurement method Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 18 GHz Zakres: (0,6-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method","reference":"enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17","norm_bases":["enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 kHz do 18 GHz Zakres: (0,6-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17 Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natezenie pola elektrycznego: - w zakresie czestotliwosci od 100 kHz do 18 GHz Zakres: (0,6-100) V/m Metoda pomiarowa bezposrednia Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz. 2630) Annex to the Regulation of the Minister of Climate of February 17","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Electric field strength: - in the frequency range from 100 kHz to 18 GHz Range: (0,6-100) V/m Direct measurement method Electric field strength in the frequency range from 100 kHz to 18 GHz Range: (0.6-100) V/m Direct measurement method Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)","search_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban 电场强度：- 频率范围自 100 kHz 至 18 GHz 范围：(0,6-100) V/m 直接测量法 气候部长2020年2月17日条例附录（《法律公报》2022年第2630项）","test_object_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban","methodology_de":"Elektrische Feldstärke: - im Frequenzbereich von 100 kHz bis 18 GHz Bereich: (0,6-100) V/m Direktes Messverfahren","search_de":"Umwelt – elektromagnetisches Feld in der Umgebung von Funkanlagen: Breitbandmessungen Elektrische Feldstärke: - im Frequenzbereich von 100 kHz bis 18 GHz Bereich: (0,6-100) V/m Direktes Messverfahren Anhang zur Verordnung des Klimaministers vom 17.02.2020 (Gesetzblatt (Dz. U.) 2022, Pos. 2630)","test_object_de":"Umwelt – elektromagnetisches Feld in der Umgebung von Funkanlagen: Breitbandmessungen","methodology_zh":"电场强度：- 频率范围自 100 kHz 至 18 GHz 范围：(0,6-100) V/m 直接测量法","reference_en":"Annex to the Regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)","reference_de":"Anhang zur Verordnung des Klimaministers vom 17.02.2020 (Gesetzblatt (Dz. U.) 2022, Pos. 2630)","reference_zh":"气候部长2020年2月17日条例附录（《法律公报》2022年第2630项）","methodology_cs":"Intenzita elektrického pole: - v kmitočtovém rozsahu od 100 kHz do 18 GHz Rozsah: (0,6-100) V/m Přímá měřicí metoda","reference_cs":"…nařízení ministra klimatu ze dne 17.02.2020 (Dz.U. 2022 pol. 2630)","search_cs":"Prostředí – elektromagnetické pole v okolí radiokomunikačních instalací: širokopásmová měření Intenzita elektrického pole: - v kmitočtovém rozsahu od 100 kHz do 18 GHz Rozsah: (0,6-100) V/m Přímá měřicí metoda …nařízení ministra klimatu ze dne 17.02.2020 (Dz.U. 2022 pol. 2630)","test_object_cs":"Prostředí – elektromagnetické pole v okolí radiokomunikačních instalací: širokopásmová měření"},{"_id":"6a5a55f39af9f73f3825153a","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","test_object_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 100 kHz do 1 GHz Zakres: (0,01-10) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method","methodology_en":"Magnetic field strength: - in the frequency range from 100 kHz to 1 GHz Range: (0,01-10) A/m Direct measurement method Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 100 kHz do 1 GHz Zakres: (0,01-10) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natężenie pola magnetycznego: - w zakresie częstotliwości od 100 kHz do 1 GHz Zakres: (0,01-10) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natezenie pola magnetycznego: - w zakresie czestotliwosci od 100 kHz do 1 GHz Zakres: (0,01-10) A/m Metoda pomiarowa bezposrednia Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Magnetic field strength: - in the frequency range from 100 kHz to 1 GHz Range: (0,01-10) A/m Direct measurement method Magnetic field strength in the frequency range from 100 kHz to 1 GHz Range: (0.01-10) A/m Direct measurement method","search_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban 磁场强度：- 频率范围自 100 kHz 至 1 GHz 范围：(0,01-10) A/m 直接测量法","test_object_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban","methodology_de":"Magnetische Feldstärke: - im Frequenzbereich von 100 kHz bis 1 GHz Bereich: (0,01-10) A/m Direktes Messverfahren","search_de":"Umwelt – elektromagnetisches Feld in der Umgebung von Funkanlagen: Breitbandmessungen Magnetische Feldstärke: - im Frequenzbereich von 100 kHz bis 1 GHz Bereich: (0,01-10) A/m Direktes Messverfahren","test_object_de":"Umwelt – elektromagnetisches Feld in der Umgebung von Funkanlagen: Breitbandmessungen","methodology_zh":"磁场强度：- 频率范围自 100 kHz 至 1 GHz 范围：(0,01-10) A/m 直接测量法","methodology_cs":"Intenzita magnetického pole: - v kmitočtovém rozsahu od 100 kHz do 1 GHz Rozsah: (0,01-10) A/m Přímá měřicí metoda","search_cs":"Prostředí – elektromagnetické pole v okolí radiokomunikačních instalací: širokopásmová měření Intenzita magnetického pole: - v kmitočtovém rozsahu od 100 kHz do 1 GHz Rozsah: (0,01-10) A/m Přímá měřicí metoda","test_object_cs":"Prostředí – elektromagnetické pole v okolí radiokomunikačních instalací: širokopásmová měření"},{"_id":"6a5a55f39af9f73f3825153b","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","test_object_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 1 GHz do 18 GHz Zakres: (0,01-0,26) A/m Metoda pomiarowo-obliczeniowa Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method","methodology_en":"Magnetic field strength: - in the frequency range from 1 GHz to 18 GHz Range: (0,01-0,26) A/m Measurement and calculation method Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 1 GHz do 18 GHz Zakres: (0,01-0,26) A/m Metoda pomiarowo-obliczeniowa Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natężenie pola magnetycznego: - w zakresie częstotliwości od 1 GHz do 18 GHz Zakres: (0,01-0,26) A/m Metoda pomiarowo-obliczeniowa Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Natezenie pola magnetycznego: - w zakresie czestotliwosci od 1 GHz do 18 GHz Zakres: (0,01-0,26) A/m Metoda pomiarowo-obliczeniowa Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: broadband measurements Magnetic field strength: - in the frequency range from 1 GHz to 18 GHz Range: (0,01-0,26) A/m Measurement and calculation method Magnetic field strength in the frequency range from 1 GHz to 18 GHz Range: (0.01-0.26) A/m Measurement and calculation method","search_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban 磁场强度：- 频率范围自 1 GHz 至 18 GHz 范围：(0,01-0,26) A/m 测量-计算法","test_object_zh":"环境 － 无线电通信设施周围的电磁场：宽带测量 Environment- electromagnetic field in the vicinty of radiocommunication installations: broadban","methodology_de":"Magnetische Feldstärke: - im Frequenzbereich von 1 GHz bis 18 GHz Bereich: (0,01-0,26) A/m Mess- und Rechenverfahren","search_de":"Umwelt – elektromagnetisches Feld in der Umgebung von Funkanlagen: Breitbandmessungen Magnetische Feldstärke: - im Frequenzbereich von 1 GHz bis 18 GHz Bereich: (0,01-0,26) A/m Mess- und Rechenverfahren","test_object_de":"Umwelt – elektromagnetisches Feld in der Umgebung von Funkanlagen: Breitbandmessungen","methodology_zh":"磁场强度：- 频率范围自 1 GHz 至 18 GHz 范围：(0,01-0,26) A/m 测量-计算法","methodology_cs":"Intenzita magnetického pole: - v kmitočtovém rozsahu od 1 GHz do 18 GHz Rozsah: (0,01-0,26) A/m Měřicí a výpočetní metoda","search_cs":"Prostředí – elektromagnetické pole v okolí radiokomunikačních instalací: širokopásmová měření Intenzita magnetického pole: - v kmitočtovém rozsahu od 1 GHz do 18 GHz Rozsah: (0,01-0,26) A/m Měřicí a výpočetní metoda","test_object_cs":"Prostředí – elektromagnetické pole v okolí radiokomunikačních instalací: širokopásmová měření"},{"_id":"6a5a55f39af9f73f3825153c","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements","test_object_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz Zakres: (0,02-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method","methodology_en":"Electric field strength: - in the frequency range from 27 MHz to 6 GHz Range: (0,02-100) V/m Direct measurement method Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz Zakres: (0,02-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method","reference":"enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17","norm_bases":["enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Natężenie pola elektrycznego: - w zakresie częstotliwości od 27 MHz do 6 GHz Zakres: (0,02-100) V/m Metoda pomiarowa bezpośrednia Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17 Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Natezenie pola elektrycznego: - w zakresie czestotliwosci od 27 MHz do 6 GHz Zakres: (0,02-100) V/m Metoda pomiarowa bezposrednia Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method enia Ministra Klimatu z 17.02.2020 (Dz.U. 2022 poz.2630) Annex to the Regulation of the Minister of Climate of February 17","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Electric field strength: - in the frequency range from 27 MHz to 6 GHz Range: (0,02-100) V/m Direct measurement method Electric field strength in the frequency range from 27 MHz to 6 GHz Range: (0.02-100) V/m Direct measurement method …regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)","methodology_de":"Elektrische Feldstärke: - im Frequenzbereich von 27 MHz bis 6 GHz Bereich: (0,02-100) V/m Direktes Messverfahren","search_de":"Umwelt – elektromagnetisches Feld in der Umgebung von Funkanlagen: frequenzselektive Messungen Elektrische Feldstärke: - im Frequenzbereich von 27 MHz bis 6 GHz Bereich: (0,02-100) V/m Direktes Messverfahren …Verordnung des Ministers für Klima vom 17.02.2020 (Gesetzblatt (Dz. U.) 2022, Pos. 2630)","test_object_de":"Umwelt – elektromagnetisches Feld in der Umgebung von Funkanlagen: frequenzselektive Messungen","methodology_zh":"电场强度：- 频率范围自 27 MHz 至 6 GHz 范围：(0,02-100) V/m 直接测量法","search_zh":"环境 – 无线电通信设施周围的电磁场：选频测量 电场强度：- 频率范围自 27 MHz 至 6 GHz 范围：(0,02-100) V/m 直接测量法 ……气候部长2020年2月17日条例（《法律公报》2022年第2630项）","test_object_zh":"环境 – 无线电通信设施周围的电磁场：选频测量","reference_en":"…regulation of the Minister of Climate of 17.02.2020 (Journal of Laws 2022, item 2630)","reference_de":"…Verordnung des Ministers für Klima vom 17.02.2020 (Gesetzblatt (Dz. U.) 2022, Pos. 2630)","reference_zh":"……气候部长2020年2月17日条例（《法律公报》2022年第2630项）","methodology_cs":"Intenzita elektrického pole: - v kmitočtovém rozsahu od 27 MHz do 6 GHz Rozsah: (0,02-100) V/m Přímá měřicí metoda","reference_cs":"…nařízení ministra klimatu ze dne 17.02.2020 (Dz.U. 2022 pol.2630)","search_cs":"Prostředí – elektromagnetické pole v okolí radiokomunikačních instalací: selektivní měření Intenzita elektrického pole: - v kmitočtovém rozsahu od 27 MHz do 6 GHz Rozsah: (0,02-100) V/m Přímá měřicí metoda …nařízení ministra klimatu ze dne 17.02.2020 (Dz.U. 2022 pol.2630)","test_object_cs":"Prostředí – elektromagnetické pole v okolí radiokomunikačních instalací: selektivní měření"},{"_id":"6a5a55f39af9f73f3825153d","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements","test_object_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 9 kHz do 250 MHz Zakres: (0,001-0,5) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method","methodology_en":"Magnetic field strength: - in the frequency range from 9 kHz to 250 MHz Range: (0,001-0,5) A/m Direct measurement method Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 9 kHz do 250 MHz Zakres: (0,001-0,5) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Natężenie pola magnetycznego: - w zakresie częstotliwości od 9 kHz do 250 MHz Zakres: (0,001-0,5) A/m Metoda pomiarowa bezpośrednia Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Natezenie pola magnetycznego: - w zakresie czestotliwosci od 9 kHz do 250 MHz Zakres: (0,001-0,5) A/m Metoda pomiarowa bezposrednia Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment- electromagnetic field in the vicinty of radiocommunication installations: selective measurements Magnetic field strength: - in the frequency range from 9 kHz to 250 MHz Range: (0,001-0,5) A/m Direct measurement method Magnetic field strength in the frequency range from 9 kHz to 250 MHz Range: (0.001-0.5) A/m Direct measurement method","methodology_de":"Magnetische Feldstärke: - im Frequenzbereich von 9 kHz bis 250 MHz Bereich: (0,001-0,5) A/m Direktes Messverfahren","search_de":"Umwelt – elektromagnetisches Feld in der Umgebung von Funkanlagen: frequenzselektive Messungen Magnetische Feldstärke: - im Frequenzbereich von 9 kHz bis 250 MHz Bereich: (0,001-0,5) A/m Direktes Messverfahren","test_object_de":"Umwelt – elektromagnetisches Feld in der Umgebung von Funkanlagen: frequenzselektive Messungen","methodology_zh":"磁场强度：- 频率范围自 9 kHz 至 250 MHz 范围：(0,001-0,5) A/m 直接测量法","search_zh":"环境 – 无线电通信设施周围的电磁场：选频测量 磁场强度：- 频率范围自 9 kHz 至 250 MHz 范围：(0,001-0,5) A/m 直接测量法","test_object_zh":"环境 – 无线电通信设施周围的电磁场：选频测量","methodology_cs":"Intenzita magnetického pole: - v kmitočtovém rozsahu od 9 kHz do 250 MHz Rozsah: (0,001-0,5) A/m Přímá měřicí metoda","search_cs":"Prostředí – elektromagnetické pole v okolí radiokomunikačních instalací: selektivní měření Intenzita magnetického pole: - v kmitočtovém rozsahu od 9 kHz do 250 MHz Rozsah: (0,001-0,5) A/m Přímá měřicí metoda","test_object_cs":"Prostředí – elektromagnetické pole v okolí radiokomunikačních instalací: selektivní měření"},{"_id":"6a5a55f39af9f73f3825153e","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy Promieniowanie laserowe Work station Laser radiation","test_object_en":"Work station Laser radiation","methodology":"Moc promieniowania laserowego w zakresie spektralnym od 0,19 µm do 11 µm Zakres: (500 ·10-6-10) W Metoda pomiarowa bezpośrednia Energia promieniowania laserowego w zakresie spektralnym od 0,15 µm do 12 µm Zakres: (0,1 ·10-6-1) J Metoda pomiarowa bezpośrednia Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method","methodology_en":"Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc promieniowania laserowego w zakresie spektralnym od 0,19 µm do 11 µm Zakres: (500 ·10-6-10) W Metoda pomiarowa bezpośrednia Energia promieniowania laserowego w zakresie spektralnym od 0,15 µm do 12 µm Zakres: (0,1 ·10-6-1) J Metoda pomiarowa bezpośrednia Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method","reference":"PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01","norm_bases":["PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy Promieniowanie laserowe Work station Laser radiation Moc promieniowania laserowego w zakresie spektralnym od 0,19 µm do 11 µm Zakres: (500 ·10-6-10) W Metoda pomiarowa bezpośrednia Energia promieniowania laserowego w zakresie spektralnym od 0,15 µm do 12 µm Zakres: (0,1 ·10-6-1) J Metoda pomiarowa bezpośrednia Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01 Stanowiska pracy Promieniowanie laserowe Work station Laser radiation Moc promieniowania laserowego w zakresie spektralnym od 0,19 µm do 11 µm Zakres: (500 ·10-6-10) W Metoda pomiarowa bezposrednia Energia promieniowania laserowego w zakresie spektralnym od 0,15 µm do 12 µm Zakres: (0,1 ·10-6-1) J Metoda pomiarowa bezposrednia Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station Laser radiation Laser radiation power in the spectral range from 0,19 µm to 11 µm Range: (500 ·10-6-10) W Direct measurement method Laser radiation energy in the spectral range from 0,15 µm to 12 µm Range: (0,1 ·10-6-1) J Direct measurement method PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01","methodology_de":"Laserstrahlungsleistung im Spektralbereich von 0,19 µm bis 11 µm Bereich: (500 ·10-6-10) W Direktes Messverfahren Laserstrahlungsenergie im Spektralbereich von 0,15 µm bis 12 µm Bereich: (0,1 ·10-6-1) J Direktes Messverfahren","search_de":"Arbeitsplätze Laserstrahlung Laserstrahlungsleistung im Spektralbereich von 0,19 µm bis 11 µm Bereich: (500 ·10-6-10) W Direktes Messverfahren Laserstrahlungsenergie im Spektralbereich von 0,15 µm bis 12 µm Bereich: (0,1 ·10-6-1) J Direktes Messverfahren PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01","test_object_de":"Arbeitsplätze Laserstrahlung","methodology_zh":"光谱范围自 0,19 µm 至 11 µm 的激光辐射功率 范围：(500 ·10-6-10) W 直接测量法 光谱范围自 0,15 µm 至 12 µm 的激光辐射能量 范围：(0,1 ·10-6-1) J 直接测量法","search_zh":"工作岗位 激光辐射 光谱范围自 0,19 µm 至 11 µm 的激光辐射功率 范围：(500 ·10-6-10) W 直接测量法 光谱范围自 0,15 µm 至 12 µm 的激光辐射能量 范围：(0,1 ·10-6-1) J 直接测量法 PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01","test_object_zh":"工作岗位 激光辐射","methodology_cs":"Výkon laserového záření ve spektrálním rozsahu od 0,19 µm do 11 µm Rozsah: (500 ·10-6-10) W Přímá měřicí metoda Energie laserového záření ve spektrálním rozsahu od 0,15 µm do 12 µm Rozsah: (0,1 ·10-6-1) J Přímá měřicí metoda","search_cs":"Pracovní místa Laserové záření Výkon laserového záření ve spektrálním rozsahu od 0,19 µm do 11 µm Rozsah: (500 ·10-6-10) W Přímá měřicí metoda Energie laserového záření ve spektrálním rozsahu od 0,15 µm do 12 µm Rozsah: (0,1 ·10-6-1) J Přímá měřicí metoda PN-EN 60825-1:2014-11 PN-EN 60825-1:2014/A11:2021-12 PN-EN ISO 11554:2018-01","test_object_cs":"Pracovní místa Laserové záření"},{"_id":"6a5a55f39af9f73f3825153f","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy Oświetlenie elektryczne we wnętrzach Work station Indoor electrical lighting","test_object_en":"Work station Indoor electrical lighting","methodology":"Natężenie oświetlenia w zakresie 20 lx-5000 lx Metoda pomiarowa bezpośrednia Illuminance in the range 20 lx-5000 lx Direct measurement method","methodology_en":"Illuminance in the range 20 lx-5000 lx Direct measurement method Illuminance in the range 20 lx-5000 lx Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia w zakresie 20 lx-5000 lx Metoda pomiarowa bezpośrednia Illuminance in the range 20 lx-5000 lx Direct measurement method","reference":"Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022","norm_bases":["Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy Oświetlenie elektryczne we wnętrzach Work station Indoor electrical lighting Natężenie oświetlenia w zakresie 20 lx-5000 lx Metoda pomiarowa bezpośrednia Illuminance in the range 20 lx-5000 lx Direct measurement method Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022 Stanowiska pracy Oswietlenie elektryczne we wnetrzach Work station Indoor electrical lighting Natezenie oswietlenia w zakresie 20 lx-5000 lx Metoda pomiarowa bezposrednia Illuminance in the range 20 lx-5000 lx Direct measurement method Procedura badawcza NBO-1 wyd. 2 z dnia 01.06.2022 r. Test procedure NBO-1 2nd edition dated 01/06/2022","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station Indoor electrical lighting Illuminance in the range 20 lx-5000 lx Direct measurement method Illuminance in the range 20 lx-5000 lx Direct measurement method Test procedure NBO-1, 2nd edition of 01.06.2022","methodology_de":"Beleuchtungsstärke im Bereich 20 lx-5000 lx Direktes Messverfahren","search_de":"Arbeitsplätze Elektrische Innenraumbeleuchtung Beleuchtungsstärke im Bereich 20 lx-5000 lx Direktes Messverfahren Prüfverfahren NBO-1, Ausg. 2 vom 01.06.2022","test_object_de":"Arbeitsplätze Elektrische Innenraumbeleuchtung","methodology_zh":"照度，范围 20 lx-5000 lx 直接测量法","search_zh":"工作岗位 室内电气照明 照度，范围 20 lx-5000 lx 直接测量法 检测程序NBO-1，第2版（2022年6月1日）","test_object_zh":"工作岗位 室内电气照明","reference_en":"Test procedure NBO-1, 2nd edition of 01.06.2022","reference_de":"Prüfverfahren NBO-1, Ausg. 2 vom 01.06.2022","reference_zh":"检测程序NBO-1，第2版（2022年6月1日）","methodology_cs":"Intenzita osvětlení v rozsahu 20 lx-5000 lx Přímá měřicí metoda","reference_cs":"Zkušební postup NBO-1 vyd. 2 ze dne 01.06.2022","search_cs":"Pracovní místa Elektrické osvětlení vnitřních prostor Intenzita osvětlení v rozsahu 20 lx-5000 lx Přímá měřicí metoda Zkušební postup NBO-1 vyd. 2 ze dne 01.06.2022","test_object_cs":"Pracovní místa Elektrické osvětlení vnitřních prostor"},{"_id":"6a5a55f39af9f73f38251540","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Stanowiska pracy Oświetlenie elektryczne we wnętrzach Work station Indoor electrical lighting","test_object_en":"Work station Indoor electrical lighting","methodology":"Równomierność oświetlenia na stanowisku pracy (z obliczeń) Uniformity of illumination on work station","methodology_en":"Uniformity of illumination on work station","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia na stanowisku pracy (z obliczeń) Uniformity of illumination on work station","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stanowiska pracy Oświetlenie elektryczne we wnętrzach Work station Indoor electrical lighting Równomierność oświetlenia na stanowisku pracy (z obliczeń) Uniformity of illumination on work station Stanowiska pracy Oswietlenie elektryczne we wnetrzach Work station Indoor electrical lighting Rownomiernosc oswietlenia na stanowisku pracy (z obliczen) Uniformity of illumination on work station","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Work station Indoor electrical lighting Uniformity of illumination on work station","methodology_de":"Gleichmäßigkeit der Beleuchtung am Arbeitsplatz (berechnet)","search_de":"Arbeitsplätze Elektrische Innenraumbeleuchtung Gleichmäßigkeit der Beleuchtung am Arbeitsplatz (berechnet)","test_object_de":"Arbeitsplätze Elektrische Innenraumbeleuchtung","methodology_zh":"工作岗位照明均匀度（计算得出）","search_zh":"工作岗位 室内电气照明 工作岗位照明均匀度（计算得出）","test_object_zh":"工作岗位 室内电气照明","methodology_cs":"Rovnoměrnost osvětlení na pracovním místě (výpočtem)","search_cs":"Pracovní místa Elektrické osvětlení vnitřních prostor Rovnoměrnost osvětlení na pracovním místě (výpočtem)","test_object_cs":"Pracovní místa Elektrické osvětlení vnitřních prostor"},{"_id":"6a5a55f39af9f73f38251541","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczne natężenie napromienienia promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia. Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm (z obliczeń) Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations)","methodology_en":"Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne natężenie napromienienia promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia. Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm (z obliczeń) Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations)","reference":"PN-EN 14255-2:2010 Metoda O Method O","norm_bases":["PN-EN 14255-2:2010 Metoda O Method O"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natężenie napromienienia promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia. Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm (z obliczeń) Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations) PN-EN 14255-2:2010 Metoda O Method O Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natezenie napromienienia promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Metoda pomiarowa bezposrednia. Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm (z obliczen) Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations) PN-EN 14255-2:2010 Metoda O Method O","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective irradiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (7,41 ∙ 10-6-7,41 ∙ 103) W/m2 Direct measurement method Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm (from calculations) PN-EN 14255-2:2010 Method O","search_zh":"工作环境 － 非激光光辐射 305 nm 至 700 nm 光谱范围内可见光辐射的有效辐照度 范围：(7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 直接测量法。305 nm 至 700 nm 光谱范围内可见光辐射的有效辐亮度（计算得出） PN-EN 14255-2:2010 方法O","test_object_zh":"工作环境 － 非激光光辐射","methodology_de":"Effektive Bestrahlungsstärke sichtbarer Strahlung im Spektralbereich von 305 nm bis 700 nm Bereich: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Direktes Messverfahren. Effektive Strahldichte sichtbarer Strahlung im Spektralbereich von 305 nm bis 700 nm (berechnet)","search_de":"Arbeitsumgebung - inkohärente optische Strahlung Effektive Bestrahlungsstärke sichtbarer Strahlung im Spektralbereich von 305 nm bis 700 nm Bereich: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Direktes Messverfahren. Effektive Strahldichte sichtbarer Strahlung im Spektralbereich von 305 nm bis 700 nm (berechnet) PN-EN 14255-2:2010 Verfahren O","test_object_de":"Arbeitsumgebung - inkohärente optische Strahlung","methodology_zh":"305 nm 至 700 nm 光谱范围内可见光辐射的有效辐照度 范围：(7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 直接测量法。305 nm 至 700 nm 光谱范围内可见光辐射的有效辐亮度（计算得出）","reference_en":"PN-EN 14255-2:2010 Method O","reference_de":"PN-EN 14255-2:2010 Verfahren O","reference_zh":"PN-EN 14255-2:2010 方法O","search_cs":"Pracovní prostředí - nelaserové optické záření Efektivní intenzita ozáření viditelným zářením ve spektrálním rozsahu od 305 nm do 700 nm Rozsah: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Přímá měřicí metoda. Efektivní zář viditelného záření ve spektrálním rozsahu od 305 nm do 700 nm (výpočtem) PN-EN 14255-2:2010 Metoda O","test_object_cs":"Pracovní prostředí - nelaserové optické záření","methodology_cs":"Efektivní intenzita ozáření viditelným zářením ve spektrálním rozsahu od 305 nm do 700 nm Rozsah: (7,41 ∙ 10-6-7,41 ∙ 103 )W/m2 Přímá měřicí metoda. Efektivní zář viditelného záření ve spektrálním rozsahu od 305 nm do 700 nm (výpočtem)","reference_cs":"PN-EN 14255-2:2010 Metoda O"},{"_id":"6a5a55f39af9f73f38251542","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Metoda pomiarowa bezpośrednia Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method","methodology_en":"Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Metoda pomiarowa bezpośrednia Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method","reference":"PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R","norm_bases":["PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Metoda pomiarowa bezpośrednia Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna promieniowania widzialnego w zakresie spektralnym od 305 nm do 700 nm Zakres: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Metoda pomiarowa bezposrednia Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method PN-EN 14255-2:2010 Metoda D Method D Metoda X Method X Metoda R Method R","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective radiance of visible radiation in the spectral range from 305 nm to 700 nm Range: (5,56 ∙ 10-5-5,56 ∙ 104) W/m2 ∙ sr Direct measurement method PN-EN 14255-2:2010 Method D, Method X, Method R","search_zh":"工作环境 － 非激光光辐射 305 nm 至 700 nm 光谱范围内可见光辐射的有效辐亮度 范围：(5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr 直接测量法 PN-EN 14255-2:2010 方法D、方法X、方法R","test_object_zh":"工作环境 － 非激光光辐射","methodology_de":"Effektive Strahldichte sichtbarer Strahlung im Spektralbereich von 305 nm bis 700 nm Bereich: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Direktes Messverfahren","search_de":"Arbeitsumgebung - inkohärente optische Strahlung Effektive Strahldichte sichtbarer Strahlung im Spektralbereich von 305 nm bis 700 nm Bereich: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Direktes Messverfahren PN-EN 14255-2:2010 Verfahren D, Verfahren X, Verfahren R","test_object_de":"Arbeitsumgebung - inkohärente optische Strahlung","methodology_zh":"305 nm 至 700 nm 光谱范围内可见光辐射的有效辐亮度 范围：(5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr 直接测量法","reference_en":"PN-EN 14255-2:2010 Method D, Method X, Method R","reference_de":"PN-EN 14255-2:2010 Verfahren D, Verfahren X, Verfahren R","reference_zh":"PN-EN 14255-2:2010 方法D、方法X、方法R","search_cs":"Pracovní prostředí - nelaserové optické záření Efektivní zář viditelného záření ve spektrálním rozsahu od 305 nm do 700 nm Rozsah: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Přímá měřicí metoda PN-EN 14255-2:2010 Metoda D Metoda X Metoda R","test_object_cs":"Pracovní prostředí - nelaserové optické záření","methodology_cs":"Efektivní zář viditelného záření ve spektrálním rozsahu od 305 nm do 700 nm Rozsah: (5,56 ∙ 10-5-5,56 ∙ 104 )W/m2 ∙ sr Přímá měřicí metoda","reference_cs":"PN-EN 14255-2:2010 Metoda D Metoda X Metoda R"},{"_id":"6a5a55f39af9f73f38251543","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Natężenie napromienienia promieniowania nadfioletowego, widzialnego i podczerwonego w zakresie spektralnym od 200 nm do 40 000 nm Zakres: (0,2-2,22 103) W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym, widzialnym i podczerwonym w zakresie spektralnym od 200 nm do 40000 nm (z obliczeń) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)","methodology_en":"Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Radiant exposure to ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40000 nm (calculated) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie napromienienia promieniowania nadfioletowego, widzialnego i podczerwonego w zakresie spektralnym od 200 nm do 40 000 nm Zakres: (0,2-2,22 103) W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym, widzialnym i podczerwonym w zakresie spektralnym od 200 nm do 40000 nm (z obliczeń) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natężenie napromienienia promieniowania nadfioletowego, widzialnego i podczerwonego w zakresie spektralnym od 200 nm do 40 000 nm Zakres: (0,2-2,22 103) W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym, widzialnym i podczerwonym w zakresie spektralnym od 200 nm do 40000 nm (z obliczeń) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations) Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natezenie napromienienia promieniowania nadfioletowego, widzialnego i podczerwonego w zakresie spektralnym od 200 nm do 40 000 nm Zakres: (0,2-2,22 103) W/m2 Metoda pomiarowa bezposrednia Napromienienie promieniowaniem nadfioletowym, widzialnym i podczerwonym w zakresie spektralnym od 200 nm do 40000 nm (z obliczen) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Radiant exposure to ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40000 nm (calculated) Irradiance of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm Range: (0,2-2,22 103) W/m2 Direct measurement method Irradiation of ultraviolet, visible and infrared radiation in the spectral range from 200 nm to 40 000 nm (from calculations)","search_zh":"工作环境 － 非激光光辐射 紫外、可见和红外辐射辐照度，光谱范围自 200 nm 至 40 000 nm 范围：(0,2-2,22 103) W/m2 直接测量法 紫外、可见和红外辐射辐照量，光谱范围自 200 nm 至 40000 nm（计算得出）","test_object_zh":"工作环境 － 非激光光辐射","methodology_de":"Bestrahlungsstärke durch ultraviolette, sichtbare und infrarote Strahlung im Spektralbereich von 200 nm bis 40 000 nm Bereich: (0,2-2,22 103) W/m2 Direktes Messverfahren Bestrahlung durch ultraviolette, sichtbare und infrarote Strahlung im Spektralbereich von 200 nm bis 40000 nm (berechnet)","search_de":"Arbeitsumgebung - inkohärente optische Strahlung Bestrahlungsstärke durch ultraviolette, sichtbare und infrarote Strahlung im Spektralbereich von 200 nm bis 40 000 nm Bereich: (0,2-2,22 103) W/m2 Direktes Messverfahren Bestrahlung durch ultraviolette, sichtbare und infrarote Strahlung im Spektralbereich von 200 nm bis 40000 nm (berechnet)","test_object_de":"Arbeitsumgebung - inkohärente optische Strahlung","methodology_zh":"紫外、可见和红外辐射辐照度，光谱范围自 200 nm 至 40 000 nm 范围：(0,2-2,22 103) W/m2 直接测量法 紫外、可见和红外辐射辐照量，光谱范围自 200 nm 至 40000 nm（计算得出）","search_cs":"Pracovní prostředí - nelaserové optické záření Intenzita ozáření ultrafialovým, viditelným a infračerveným zářením ve spektrálním rozsahu od 200 nm do 40 000 nm Rozsah: (0,2-2,22 103) W/m2 Přímá měřicí metoda Ozáření ultrafialovým, viditelným a infračerveným zářením ve spektrálním rozsahu od 200 nm do 40000 nm (výpočtem)","test_object_cs":"Pracovní prostředí - nelaserové optické záření","methodology_cs":"Intenzita ozáření ultrafialovým, viditelným a infračerveným zářením ve spektrálním rozsahu od 200 nm do 40 000 nm Rozsah: (0,2-2,22 103) W/m2 Přímá měřicí metoda Ozáření ultrafialovým, viditelným a infračerveným zářením ve spektrálním rozsahu od 200 nm do 40000 nm (výpočtem)"},{"_id":"6a5a55f39af9f73f38251544","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Natężenie napromienienia bliską i średnią podczerwienią w zakresie spektralnym od 770 nm do 3 000 nm. Zakres: (0,857-9,52 ∙ 103)W/m2. Metoda pomiarowa bezpośrednia Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method","methodology_en":"Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie napromienienia bliską i średnią podczerwienią w zakresie spektralnym od 770 nm do 3 000 nm. Zakres: (0,857-9,52 ∙ 103)W/m2. Metoda pomiarowa bezpośrednia Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natężenie napromienienia bliską i średnią podczerwienią w zakresie spektralnym od 770 nm do 3 000 nm. Zakres: (0,857-9,52 ∙ 103)W/m2. Metoda pomiarowa bezpośrednia Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natezenie napromienienia bliska i srednia podczerwienia w zakresie spektralnym od 770 nm do 3 000 nm. Zakres: (0,857-9,52 ∙ 103)W/m2. Metoda pomiarowa bezposrednia Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method Irradiance of near- and mid-infrared radiation in the spectral range from 770 nm to 3 000 nm. Range: (0,857-9,52 ∙ 103)W/m2. Direct measurement method","search_zh":"工作环境 － 非激光光辐射 近红外和中红外辐照度，光谱范围自 770 nm 至 3 000 nm。范围：(0,857-9,52 ∙ 103)W/m2。直接测量法","test_object_zh":"工作环境 － 非激光光辐射","methodology_de":"Bestrahlungsstärke durch nahe und mittlere Infrarotstrahlung im Spektralbereich von 770 nm bis 3 000 nm. Bereich: (0,857-9,52 ∙ 103)W/m2. Direktes Messverfahren","search_de":"Arbeitsumgebung - inkohärente optische Strahlung Bestrahlungsstärke durch nahe und mittlere Infrarotstrahlung im Spektralbereich von 770 nm bis 3 000 nm. Bereich: (0,857-9,52 ∙ 103)W/m2. Direktes Messverfahren","test_object_de":"Arbeitsumgebung - inkohärente optische Strahlung","methodology_zh":"近红外和中红外辐照度，光谱范围自 770 nm 至 3 000 nm。范围：(0,857-9,52 ∙ 103)W/m2。直接测量法","search_cs":"Pracovní prostředí - nelaserové optické záření Intenzita ozáření blízkým a středním infračerveným zářením ve spektrálním rozsahu od 770 nm do 3 000 nm. Rozsah: (0,857-9,52 ∙ 103)W/m2. Přímá měřicí metoda","test_object_cs":"Pracovní prostředí - nelaserové optické záření","methodology_cs":"Intenzita ozáření blízkým a středním infračerveným zářením ve spektrálním rozsahu od 770 nm do 3 000 nm. Rozsah: (0,857-9,52 ∙ 103)W/m2. Přímá měřicí metoda"},{"_id":"6a5a55f39af9f73f38251545","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczna luminancja energetyczna źródła promieniowania widzialnego i bliskiej podczerwieni w zakresie spektralnym od 305 do 1400 nm Metoda pomiarowa i obliczeniowa Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method","methodology_en":"Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna luminancja energetyczna źródła promieniowania widzialnego i bliskiej podczerwieni w zakresie spektralnym od 305 do 1400 nm Metoda pomiarowa i obliczeniowa Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method","reference":"PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r.","norm_bases":["PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna źródła promieniowania widzialnego i bliskiej podczerwieni w zakresie spektralnym od 305 do 1400 nm Metoda pomiarowa i obliczeniowa Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r. Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna zrodla promieniowania widzialnego i bliskiej podczerwieni w zakresie spektralnym od 305 do 1400 nm Metoda pomiarowa i obliczeniowa Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method PN-EN 14255-2:2010 Metoda D Method D PN-T 05687:2002 p. 2.5.5. Instrukcji nr 1/NF3 wydanie z dnia 11.10.2023 r.","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective radiance of a source of visible and near-infrared radiation in the spectral range from 305 to 1400 nm Measurement and calculation method PN-EN 14255-2:2010 Method D; PN-T 05687:2002 cl. 2.5.5.; Instruction No. 1/NF3, issue of 11.10.2023","search_zh":"工作环境 － 非激光光辐射 305 至 1400 nm 光谱范围内可见光和近红外辐射源的有效辐亮度 测量和计算法 PN-EN 14255-2:2010 方法D；PN-T 05687:2002 第2.5.5.条；作业指导书第1/NF3号，2023年10月11日版","test_object_zh":"工作环境 － 非激光光辐射","methodology_de":"Effektive Strahldichte einer Quelle sichtbarer und nahinfraroter Strahlung im Spektralbereich von 305 bis 1400 nm Mess- und Berechnungsverfahren","search_de":"Arbeitsumgebung - inkohärente optische Strahlung Effektive Strahldichte einer Quelle sichtbarer und nahinfraroter Strahlung im Spektralbereich von 305 bis 1400 nm Mess- und Berechnungsverfahren PN-EN 14255-2:2010 Verfahren D; PN-T 05687:2002 Abschn. 2.5.5.; Anweisung Nr. 1/NF3, Ausgabe vom 11.10.2023","test_object_de":"Arbeitsumgebung - inkohärente optische Strahlung","methodology_zh":"305 至 1400 nm 光谱范围内可见光和近红外辐射源的有效辐亮度 测量和计算法","reference_en":"PN-EN 14255-2:2010 Method D; PN-T 05687:2002 cl. 2.5.5.; Instruction No. 1/NF3, issue of 11.10.2023","reference_de":"PN-EN 14255-2:2010 Verfahren D; PN-T 05687:2002 Abschn. 2.5.5.; Anweisung Nr. 1/NF3, Ausgabe vom 11.10.2023","reference_zh":"PN-EN 14255-2:2010 方法D；PN-T 05687:2002 第2.5.5.条；作业指导书第1/NF3号，2023年10月11日版","search_cs":"Pracovní prostředí - nelaserové optické záření Efektivní zář zdroje viditelného a blízkého infračerveného záření ve spektrálním rozsahu od 305 do 1400 nm Měřicí a výpočetní metoda PN-EN 14255-2:2010 Metoda D PN-T 05687:2002 čl. 2.5.5. Instrukce č. 1/NF3 vydání ze dne 11.10.2023","test_object_cs":"Pracovní prostředí - nelaserové optické záření","methodology_cs":"Efektivní zář zdroje viditelného a blízkého infračerveného záření ve spektrálním rozsahu od 305 do 1400 nm Měřicí a výpočetní metoda","reference_cs":"PN-EN 14255-2:2010 Metoda D PN-T 05687:2002 čl. 2.5.5. Instrukce č. 1/NF3 vydání ze dne 11.10.2023"},{"_id":"6a5a55f39af9f73f38251546","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczne natężenie napromienienia bliską podczerwienią w zakresie spektralnym od 770 nm do 1400 nm Zakres: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Metoda pomiarowa bezpośrednia Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method","methodology_en":"Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne natężenie napromienienia bliską podczerwienią w zakresie spektralnym od 770 nm do 1400 nm Zakres: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Metoda pomiarowa bezpośrednia Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method","reference":"PN-T 05687:2002","norm_bases":["PN-T 05687:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natężenie napromienienia bliską podczerwienią w zakresie spektralnym od 770 nm do 1400 nm Zakres: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Metoda pomiarowa bezpośrednia Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method PN-T 05687:2002 Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natezenie napromienienia bliska podczerwienia w zakresie spektralnym od 770 nm do 1400 nm Zakres: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Metoda pomiarowa bezposrednia Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method PN-T 05687:2002","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective irradiance of near-infrared radiation in the spectral range from 770 nm to 1400 nm Range: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direct measurement method PN-T 05687:2002","search_zh":"工作环境 － 非激光光辐射 770 nm 至 1400 nm 光谱范围内近红外辐射的有效辐照度 范围：(3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 直接测量法 PN-T 05687:2002","test_object_zh":"工作环境 － 非激光光辐射","methodology_de":"Effektive Bestrahlungsstärke durch nahes Infrarot im Spektralbereich von 770 nm bis 1400 nm Bereich: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direktes Messverfahren","search_de":"Arbeitsumgebung - inkohärente optische Strahlung Effektive Bestrahlungsstärke durch nahes Infrarot im Spektralbereich von 770 nm bis 1400 nm Bereich: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Direktes Messverfahren PN-T 05687:2002","test_object_de":"Arbeitsumgebung - inkohärente optische Strahlung","methodology_zh":"770 nm 至 1400 nm 光谱范围内近红外辐射的有效辐照度 范围：(3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 直接测量法","search_cs":"Pracovní prostředí - nelaserové optické záření Efektivní intenzita ozáření blízkým infračerveným zářením ve spektrálním rozsahu od 770 nm do 1400 nm Rozsah: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Přímá měřicí metoda PN-T 05687:2002","test_object_cs":"Pracovní prostředí - nelaserové optické záření","methodology_cs":"Efektivní intenzita ozáření blízkým infračerveným zářením ve spektrálním rozsahu od 770 nm do 1400 nm Rozsah: (3,57 ∙ 10-5-1,25 ∙ 102 ) W/m2 Přímá měřicí metoda"},{"_id":"6a5a55f39af9f73f38251547","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczna luminancja energetyczna w zakresie spektralnym od 770 nm do 1400 nm (z obliczeń) Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)","methodology_en":"Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna luminancja energetyczna w zakresie spektralnym od 770 nm do 1400 nm (z obliczeń) Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna w zakresie spektralnym od 770 nm do 1400 nm (z obliczeń) Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations) Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczna luminancja energetyczna w zakresie spektralnym od 770 nm do 1400 nm (z obliczen) Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective radiance in the spectral range from 770 nm to 1400 nm (from calculations)","search_zh":"工作环境 － 非激光光辐射 770 nm 至 1400 nm 光谱范围内的有效辐亮度（计算得出）","test_object_zh":"工作环境 － 非激光光辐射","methodology_de":"Effektive Strahldichte im Spektralbereich von 770 nm bis 1400 nm (berechnet)","search_de":"Arbeitsumgebung - inkohärente optische Strahlung Effektive Strahldichte im Spektralbereich von 770 nm bis 1400 nm (berechnet)","test_object_de":"Arbeitsumgebung - inkohärente optische Strahlung","methodology_zh":"770 nm 至 1400 nm 光谱范围内的有效辐亮度（计算得出）","search_cs":"Pracovní prostředí - nelaserové optické záření Efektivní zář ve spektrálním rozsahu od 770 nm do 1400 nm (výpočtem)","test_object_cs":"Pracovní prostředí - nelaserové optické záření","methodology_cs":"Efektivní zář ve spektrálním rozsahu od 770 nm do 1400 nm (výpočtem)"},{"_id":"6a5a55f39af9f73f38251548","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Skuteczne natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 235 nm do 307 nm. Zakres: (5 ∙ 10-5-25) W/m2 Metoda pomiarowa bezpośrednia Skuteczne napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 235 nm do 307 nm (z obliczeń) Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations)","methodology_en":"Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 235 nm do 307 nm. Zakres: (5 ∙ 10-5-25) W/m2 Metoda pomiarowa bezpośrednia Skuteczne napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 235 nm do 307 nm (z obliczeń) Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations)","reference":"PN-EN 14255-1:2010 Metoda A Method A","norm_bases":["PN-EN 14255-1:2010 Metoda A Method A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 235 nm do 307 nm. Zakres: (5 ∙ 10-5-25) W/m2 Metoda pomiarowa bezpośrednia Skuteczne napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 235 nm do 307 nm (z obliczeń) Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations) PN-EN 14255-1:2010 Metoda A Method A Srodowisko pracy - nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Skuteczne natezenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 235 nm do 307 nm. Zakres: (5 ∙ 10-5-25) W/m2 Metoda pomiarowa bezposrednia Skuteczne napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 235 nm do 307 nm (z obliczen) Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations) PN-EN 14255-1:2010 Metoda A Method A","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Effective irradiance of ultraviolet radiation in the spectral range from 235 nm to 307 nm. Range: (5 ∙ 10-5-25) W/m2 Direct measurement method Effective irradiation of ultraviolet radiation in the spectral range from 235 nm to 307 nm (from calculations) PN-EN 14255-1:2010 Method A","search_zh":"工作环境 － 非激光光辐射 235 nm 至 307 nm 光谱范围内紫外辐射的有效辐照度。范围：(5 ∙ 10-5-25) W/m2 直接测量法 235 nm 至 307 nm 光谱范围内紫外辐射的有效辐照量（计算得出） PN-EN 14255-1:2010 方法A","test_object_zh":"工作环境 － 非激光光辐射","methodology_de":"Effektive Bestrahlungsstärke der Ultraviolettstrahlung im Spektralbereich von 235 nm bis 307 nm. Bereich: (5 ∙ 10-5-25) W/m2 Direktes Messverfahren Effektive Bestrahlung durch Ultraviolettstrahlung im Spektralbereich von 235 nm bis 307 nm (berechnet)","search_de":"Arbeitsumgebung - inkohärente optische Strahlung Effektive Bestrahlungsstärke der Ultraviolettstrahlung im Spektralbereich von 235 nm bis 307 nm. Bereich: (5 ∙ 10-5-25) W/m2 Direktes Messverfahren Effektive Bestrahlung durch Ultraviolettstrahlung im Spektralbereich von 235 nm bis 307 nm (berechnet) PN-EN 14255-1:2010 Verfahren A","test_object_de":"Arbeitsumgebung - inkohärente optische Strahlung","methodology_zh":"235 nm 至 307 nm 光谱范围内紫外辐射的有效辐照度。范围：(5 ∙ 10-5-25) W/m2 直接测量法 235 nm 至 307 nm 光谱范围内紫外辐射的有效辐照量（计算得出）","reference_en":"PN-EN 14255-1:2010 Method A","reference_de":"PN-EN 14255-1:2010 Verfahren A","reference_zh":"PN-EN 14255-1:2010 方法A","search_cs":"Pracovní prostředí - nelaserové optické záření Efektivní intenzita ozáření ultrafialovým zářením ve spektrálním rozsahu od 235 nm do 307 nm. Rozsah: (5 ∙ 10-5-25) W/m2 Přímá měřicí metoda Efektivní ozáření ultrafialovým zářením ve spektrálním rozsahu od 235 nm do 307 nm (výpočtem) PN-EN 14255-1:2010 Metoda A","test_object_cs":"Pracovní prostředí - nelaserové optické záření","methodology_cs":"Efektivní intenzita ozáření ultrafialovým zářením ve spektrálním rozsahu od 235 nm do 307 nm. Rozsah: (5 ∙ 10-5-25) W/m2 Přímá měřicí metoda Efektivní ozáření ultrafialovým zářením ve spektrálním rozsahu od 235 nm do 307 nm (výpočtem)","reference_cs":"PN-EN 14255-1:2010 Metoda A"},{"_id":"6a5a55f39af9f73f38251549","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy Nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation","test_object_en":"Working environment Non-laser optical radiation","methodology":"Natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 315 nm do 390 nm. Zakres: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 315 nm do 390 nm (z obliczeń) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations)","methodology_en":"Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Radiant exposure to ultraviolet radiation in the spectral range from 315 nm to 390 nm (calculated) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 315 nm do 390 nm. Zakres: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 315 nm do 390 nm (z obliczeń) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations)","reference":"PN-EN 14255-1:2010 Metoda M Method M","norm_bases":["PN-EN 14255-1:2010 Metoda M Method M"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy Nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natężenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 315 nm do 390 nm. Zakres: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Metoda pomiarowa bezpośrednia Napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 315 nm do 390 nm (z obliczeń) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations) PN-EN 14255-1:2010 Metoda M Method M Srodowisko pracy Nielaserowe promieniowanie optyczne Working environment Non-laser optical radiation Natezenie napromienienia promieniowania nadfioletowego w zakresie spektralnym od 315 nm do 390 nm. Zakres: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Metoda pomiarowa bezposrednia Napromienienie promieniowaniem nadfioletowym w zakresie spektralnym od 315 nm do 390 nm (z obliczen) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations) PN-EN 14255-1:2010 Metoda M Method M","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Non-laser optical radiation Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Radiant exposure to ultraviolet radiation in the spectral range from 315 nm to 390 nm (calculated) Irradiance of ultraviolet radiation in the spectral range from 315 nm to 390 nm. Range: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direct measurement method Irradiation of ultraviolet radiation in the spectral range from 315 nm to 390 nm (from calculations) PN-EN 14255-1:2010 Method M","methodology_de":"Bestrahlungsstärke durch Ultraviolettstrahlung im Spektralbereich von 315 nm bis 390 nm. Bereich: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direktes Messverfahren Bestrahlung durch Ultraviolettstrahlung im Spektralbereich von 315 nm bis 390 nm (berechnet)","search_de":"Arbeitsumgebung Inkohärente optische Strahlung Bestrahlungsstärke durch Ultraviolettstrahlung im Spektralbereich von 315 nm bis 390 nm. Bereich: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Direktes Messverfahren Bestrahlung durch Ultraviolettstrahlung im Spektralbereich von 315 nm bis 390 nm (berechnet) PN-EN 14255-1:2010 Verfahren M","test_object_de":"Arbeitsumgebung Inkohärente optische Strahlung","methodology_zh":"紫外辐射辐照度，光谱范围自 315 nm 至 390 nm。范围：(2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 直接测量法 紫外辐射辐照量，光谱范围自 315 nm 至 390 nm（计算得出）","search_zh":"工作环境 非激光光辐射 紫外辐射辐照度，光谱范围自 315 nm 至 390 nm。范围：(2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 直接测量法 紫外辐射辐照量，光谱范围自 315 nm 至 390 nm（计算得出） PN-EN 14255-1:2010 方法M","test_object_zh":"工作环境 非激光光辐射","reference_en":"PN-EN 14255-1:2010 Method M","reference_de":"PN-EN 14255-1:2010 Verfahren M","reference_zh":"PN-EN 14255-1:2010 方法M","methodology_cs":"Intenzita ozáření ultrafialovým zářením ve spektrálním rozsahu od 315 nm do 390 nm. Rozsah: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Přímá měřicí metoda Ozáření ultrafialovým zářením ve spektrálním rozsahu od 315 nm do 390 nm (výpočtem)","reference_cs":"PN-EN 14255-1:2010 Metoda M","search_cs":"Pracovní prostředí Nelaserové optické záření Intenzita ozáření ultrafialovým zářením ve spektrálním rozsahu od 315 nm do 390 nm. Rozsah: (2,67 ∙ 10-6-2,67 ∙ 103 )W/m2 Přímá měřicí metoda Ozáření ultrafialovým zářením ve spektrálním rozsahu od 315 nm do 390 nm (výpočtem) PN-EN 14255-1:2010 Metoda M","test_object_cs":"Pracovní prostředí Nelaserové optické záření"},{"_id":"6a5a55f39af9f73f3825154a","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry Working environment- - air samples collected on filters","test_object_en":"Working environment- - air samples collected on filters","methodology":"Zawartość spalin emitowanych z silników Diesla mierzonych jako węgiel elementarny (EC) Zakres: (0,46 – 73,6) μg/cm2 Metoda termiczno-optyczna z detekcją płomieniowo-jonizacyjną (TOA-FID) Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection","methodology_en":"Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość spalin emitowanych z silników Diesla mierzonych jako węgiel elementarny (EC) Zakres: (0,46 – 73,6) μg/cm2 Metoda termiczno-optyczna z detekcją płomieniowo-jonizacyjną (TOA-FID) Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection","reference":"Podstawy i Metody Oceny Środowiska Pracy 2023, nr 1(115) s.5-25","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2023, nr 1(115) s.5-25"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Working environment- - air samples collected on filters Zawartość spalin emitowanych z silników Diesla mierzonych jako węgiel elementarny (EC) Zakres: (0,46 – 73,6) μg/cm2 Metoda termiczno-optyczna z detekcją płomieniowo-jonizacyjną (TOA-FID) Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection Podstawy i Metody Oceny Środowiska Pracy 2023, nr 1(115) s.5-25 Srodowisko pracy - probki powietrza pobrane na filtry Working environment- - air samples collected on filters Zawartosc spalin emitowanych z silnikow Diesla mierzonych jako wegiel elementarny (EC) Zakres: (0,46 – 73,6) μg/cm2 Metoda termiczno-optyczna z detekcja plomieniowo-jonizacyjna (TOA-FID) Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection Podstawy i Metody Oceny Srodowiska Pracy 2023, nr 1(115) s.5-25","categories":["environment","petro"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment- - air samples collected on filters Content of exhaust emissions from diesel engines measured as elemental carbon (EC) Range: (0.46-73.6) μg/cm2 Thermal-optical method with TOA- FID detection Principles and Methods of Assessing the Working Environment 2023, No. 1 (115), pp. 5–25","methodology_de":"Gehalt an Dieselmotoremissionen, gemessen als elementarer Kohlenstoff (EC) Bereich: (0,46 – 73,6) μg/cm2 Thermo-optisches Verfahren mit Flammenionisationsdetektion (TOA-FID)","search_de":"Arbeitsumgebung - auf Filtern gesammelte Luftproben Gehalt an Dieselmotoremissionen, gemessen als elementarer Kohlenstoff (EC) Bereich: (0,46 – 73,6) μg/cm2 Thermo-optisches Verfahren mit Flammenionisationsdetektion (TOA-FID) Grundlagen und Methoden der Bewertung der Arbeitsumgebung 2023, Nr. 1 (115), S. 5–25","test_object_de":"Arbeitsumgebung - auf Filtern gesammelte Luftproben","methodology_zh":"以元素碳（EC）计的柴油机排放尾气含量 范围：(0,46 – 73,6) μg/cm2 热光法-火焰离子化检测（TOA-FID）","search_zh":"工作环境 - 采集于滤膜上的空气样品 以元素碳（EC）计的柴油机排放尾气含量 范围：(0,46 – 73,6) μg/cm2 热光法-火焰离子化检测（TOA-FID） 《工作环境评估原则与方法》2023年第1期（总第115期），第5–25页","test_object_zh":"工作环境 - 采集于滤膜上的空气样品","reference_en":"Principles and Methods of Assessing the Working Environment 2023, No. 1 (115), pp. 5–25","reference_de":"Grundlagen und Methoden der Bewertung der Arbeitsumgebung 2023, Nr. 1 (115), S. 5–25","reference_zh":"《工作环境评估原则与方法》2023年第1期（总第115期），第5–25页","methodology_cs":"Obsah výfukových emisí z dieselových motorů měřených jako elementární uhlík (EC) Rozsah: (0,46 – 73,6) μg/cm2 Termo-optická metoda s plamenově ionizační detekcí (TOA-FID)","reference_cs":"Podstawy i Metody Oceny Środowiska Pracy (Základy a metody hodnocení pracovního prostředí) 2023, č. 1(115) s.5-25","search_cs":"Pracovní prostředí - vzorky ovzduší odebrané na filtry Obsah výfukových emisí z dieselových motorů měřených jako elementární uhlík (EC) Rozsah: (0,46 – 73,6) μg/cm2 Termo-optická metoda s plamenově ionizační detekcí (TOA-FID) Podstawy i Metody Oceny Środowiska Pracy (Základy a metody hodnocení pracovního prostředí) 2023, č. 1(115) s.5-25","test_object_cs":"Pracovní prostředí - vzorky ovzduší odebrané na filtry"},{"_id":"6a5a55f39af9f73f3825154b","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy Wydatek energetyczny Working environment Energy expenditure","test_object_en":"Working environment Energy expenditure","methodology":"Temperatura powietrza Zakres: (5-35) °C Przepływ powietrza Zakres: (10-60) dm3/min Metoda pomiarowa bezpośrednia Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method","methodology_en":"Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (5-35) °C Przepływ powietrza Zakres: (10-60) dm3/min Metoda pomiarowa bezpośrednia Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method","reference":"NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023","norm_bases":["NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy Wydatek energetyczny Working environment Energy expenditure Temperatura powietrza Zakres: (5-35) °C Przepływ powietrza Zakres: (10-60) dm3/min Metoda pomiarowa bezpośrednia Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023 Srodowisko pracy Wydatek energetyczny Working environment Energy expenditure Temperatura powietrza Zakres: (5-35) °C Przeplyw powietrza Zakres: (10-60) dm3/min Metoda pomiarowa bezposrednia Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method NEF-02 wydanie 4. z dnia 19.01.2023 r. NEF-02 4th edition dated 19/01/2023","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Energy expenditure Air temperature Range: (5-35) °C Air flow rate Range: (10-60) dm3/min Direct measurement method NEF-02, 4th edition dated 19.01.2023","methodology_de":"Lufttemperatur Bereich: (5-35) °C Luftdurchfluss Bereich: (10-60) dm3/min Direktes Messverfahren","search_de":"Arbeitsumgebung Energieumsatz Lufttemperatur Bereich: (5-35) °C Luftdurchfluss Bereich: (10-60) dm3/min Direktes Messverfahren NEF-02 Ausgabe 4 vom 19.01.2023","test_object_de":"Arbeitsumgebung Energieumsatz","methodology_zh":"空气温度 范围：(5-35) °C 空气流量 范围：(10-60) dm3/min 直接测量法","search_zh":"工作环境 能量消耗 空气温度 范围：(5-35) °C 空气流量 范围：(10-60) dm3/min 直接测量法 NEF-02 第4版（2023年1月19日）","test_object_zh":"工作环境 能量消耗","reference_en":"NEF-02, 4th edition dated 19.01.2023","reference_de":"NEF-02 Ausgabe 4 vom 19.01.2023","reference_zh":"NEF-02 第4版（2023年1月19日）","methodology_cs":"Teplota vzduchu Rozsah: (5-35) °C Průtok vzduchu Rozsah: (10-60) dm3/min Přímá měřicí metoda","reference_cs":"NEF-02 vydání 4. ze dne 19.01.2023","search_cs":"Pracovní prostředí Energetický výdej Teplota vzduchu Rozsah: (5-35) °C Průtok vzduchu Rozsah: (10-60) dm3/min Přímá měřicí metoda NEF-02 vydání 4. ze dne 19.01.2023","test_object_cs":"Pracovní prostředí Energetický výdej"},{"_id":"6a5a55f39af9f73f3825154c","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Środowisko pracy Wydatek energetyczny Working environment Energy expenditure","test_object_en":"Working environment Energy expenditure","methodology":"Wydatek energetyczny (z obliczeń) Energy expenditure (from calculation)","methodology_en":"Energy expenditure (from calculation)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydatek energetyczny (z obliczeń) Energy expenditure (from calculation)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy Wydatek energetyczny Working environment Energy expenditure Wydatek energetyczny (z obliczeń) Energy expenditure (from calculation) Srodowisko pracy Wydatek energetyczny Working environment Energy expenditure Wydatek energetyczny (z obliczen) Energy expenditure (from calculation)","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Working environment Energy expenditure Energy expenditure (from calculation)","methodology_de":"Energieumsatz (berechnet)","search_de":"Arbeitsumgebung Energieumsatz Energieumsatz (berechnet)","test_object_de":"Arbeitsumgebung Energieumsatz","methodology_zh":"能量消耗（计算得出）","search_zh":"工作环境 能量消耗 能量消耗（计算得出）","test_object_zh":"工作环境 能量消耗","methodology_cs":"Energetický výdej (výpočtem)","search_cs":"Pracovní prostředí Energetický výdej Energetický výdej (výpočtem)","test_object_cs":"Pracovní prostředí Energetický výdej"},{"_id":"6a5a55f39af9f73f3825154d","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Badania eksploatacyjne Practical performance","methodology_en":"Practical performance testing Practical performance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania eksploatacyjne Practical performance","reference":"EN 14593-1:2018 EN 13274-2:2019","norm_bases":["EN 14593-1:2018 EN 13274-2:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Badania eksploatacyjne Practical performance EN 14593-1:2018 EN 13274-2:2019 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Badania eksploatacyjne Practical performance EN 14593-1:2018 EN 13274-2:2019","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Practical performance testing Practical performance EN 14593-1:2018 EN 13274-2:2019","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 运行使用检验 Practical performance EN 14593-1:2018 EN 13274-2:2019","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器","methodology_zh":"运行使用检验 Practical performance","methodology_de":"Prüfungen der praktischen Leistungsfähigkeit","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske Prüfungen der praktischen Leistungsfähigkeit EN 14593-1:2018 EN 13274-2:2019","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou Provozní zkoušky EN 14593-1:2018 EN 13274-2:2019","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou","methodology_cs":"Provozní zkoušky"},{"_id":"6a5a55f39af9f73f3825154e","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Wytrzymałość połączeń Strength of connections","methodology_en":"Strength of connections","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość połączeń Strength of connections","reference":"EN 14593-1:2018","norm_bases":["EN 14593-1:2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Wytrzymałość połączeń Strength of connections EN 14593-1:2018 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Wytrzymalosc polaczen Strength of connections EN 14593-1:2018","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Strength of connections EN 14593-1:2018","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 连接强度 Strength of connections EN 14593-1:2018","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器","methodology_zh":"连接强度 Strength of connections","methodology_de":"Festigkeit der Verbindungen","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske Festigkeit der Verbindungen EN 14593-1:2018","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou Pevnost spojů EN 14593-1:2018","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou","methodology_cs":"Pevnost spojů"},{"_id":"6a5a55f39af9f73f3825154f","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Palność Flammability","methodology_en":"Flammability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Palność Flammability","reference":"EN 14593-1:2018 EN 13274-4:2020","norm_bases":["EN 14593-1:2018 EN 13274-4:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Palność Flammability EN 14593-1:2018 EN 13274-4:2020 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Palnosc Flammability EN 14593-1:2018 EN 13274-4:2020","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Flammability EN 14593-1:2018 EN 13274-4:2020","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 可燃性 Flammability EN 14593-1:2018 EN 13274-4:2020","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器","methodology_zh":"可燃性 Flammability","methodology_de":"Entflammbarkeit","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske Entflammbarkeit EN 14593-1:2018 EN 13274-4:2020","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou Hořlavost EN 14593-1:2018 EN 13274-4:2020","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou","methodology_cs":"Hořlavost"},{"_id":"6a5a55f39af9f73f38251550","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Przeciek wewnętrzny Inward leakage","methodology_en":"Inward leakage Inward leakage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przeciek wewnętrzny Inward leakage","reference":"EN 14593-1:2018 EN 13274-1:2001","norm_bases":["EN 14593-1:2018 EN 13274-1:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Przeciek wewnętrzny Inward leakage EN 14593-1:2018 EN 13274-1:2001 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Przeciek wewnetrzny Inward leakage EN 14593-1:2018 EN 13274-1:2001","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Inward leakage Inward leakage EN 14593-1:2018 EN 13274-1:2001","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 向内泄漏 EN 14593-1:2018 EN 13274-1:2001","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器","methodology_de":"Innenleckage","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske Innenleckage EN 14593-1:2018 EN 13274-1:2001","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske","methodology_zh":"向内泄漏","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou Průnik dovnitř EN 14593-1:2018 EN 13274-1:2001","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou","methodology_cs":"Průnik dovnitř"},{"_id":"6a5a55f39af9f73f38251551","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Opór oddychania Breathing resistance","methodology_en":"Breathing resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór oddychania Breathing resistance","reference":"EN 14593-1:2018 EN 13274-3:2001","norm_bases":["EN 14593-1:2018 EN 13274-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Opór oddychania Breathing resistance EN 14593-1:2018 EN 13274-3:2001 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Opor oddychania Breathing resistance EN 14593-1:2018 EN 13274-3:2001","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Breathing resistance EN 14593-1:2018 EN 13274-3:2001","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 呼吸阻力 Breathing resistance EN 14593-1:2018 EN 13274-3:2001","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器","methodology_zh":"呼吸阻力 Breathing resistance","methodology_de":"Atemwiderstand","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske Atemwiderstand EN 14593-1:2018 EN 13274-3:2001","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou Dýchací odpor EN 14593-1:2018 EN 13274-3:2001","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou","methodology_cs":"Dýchací odpor"},{"_id":"6a5a55f39af9f73f38251552","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air","methodology_en":"Carbon dioxide content of the inhalation air Carbon dioxide content of the inhalation air","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air","reference":"EN 14593-1:2018 EN 13274-6:2001","norm_bases":["EN 14593-1:2018 EN 13274-6:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air EN 14593-1:2018 EN 13274-6:2001 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Zawartosc dwutlenku wegla w powietrzu wdychanym Carbon dioxide content of the inhalation air EN 14593-1:2018 EN 13274-6:2001","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Carbon dioxide content of the inhalation air Carbon dioxide content of the inhalation air EN 14593-1:2018 EN 13274-6:2001","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 吸入气中二氧化碳含量 EN 14593-1:2018 EN 13274-6:2001","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器","methodology_de":"Kohlendioxidgehalt der Einatemluft","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske Kohlendioxidgehalt der Einatemluft EN 14593-1:2018 EN 13274-6:2001","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske","methodology_zh":"吸入气中二氧化碳含量","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou Obsah oxidu uhličitého ve vdechovaném vzduchu EN 14593-1:2018 EN 13274-6:2001","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou","methodology_cs":"Obsah oxidu uhličitého ve vdechovaném vzduchu"},{"_id":"6a5a55f39af9f73f38251553","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask","test_object_en":"Compressed air line breathing devices with demand valve Devices with a full face mask","methodology":"Odporność termiczna Resistance to temperature","methodology_en":"Resistance to temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność termiczna Resistance to temperature","reference":"EN 14593-2:2005","norm_bases":["EN 14593-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty z maską Compressed air line breathing devices with demand valve Devices with a full face mask Odporność termiczna Resistance to temperature EN 14593-2:2005 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty z maska Compressed air line breathing devices with demand valve Devices with a full face mask Odpornosc termiczna Resistance to temperature EN 14593-2:2005","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing devices with demand valve Devices with a full face mask Resistance to temperature EN 14593-2:2005","search_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器 耐温度性 Resistance to temperature EN 14593-2:2005","test_object_zh":"带需求阀的压缩空气长管呼吸器 配全面罩的呼吸器","methodology_zh":"耐温度性 Resistance to temperature","methodology_de":"Temperaturbeständigkeit","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske Temperaturbeständigkeit EN 14593-2:2005","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Geräte mit Vollmaske","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou Tepelná odolnost EN 14593-2:2005","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přístroje s maskou","methodology_cs":"Tepelná odolnost"},{"_id":"6a5a55f39af9f73f38251554","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Badania eksploatacyjne Practical performance","methodology_en":"Practical performance testing Practical performance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania eksploatacyjne Practical performance","reference":"EN 14593-2:2005 EN 13274-2:2019","norm_bases":["EN 14593-2:2005 EN 13274-2:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Badania eksploatacyjne Practical performance EN 14593-2:2005 EN 13274-2:2019 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Badania eksploatacyjne Practical performance EN 14593-2:2005 EN 13274-2:2019","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Practical performance testing Practical performance EN 14593-2:2005 EN 13274-2:2019","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 运行使用检验 Practical performance EN 14593-2:2005 EN 13274-2:2019","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器","methodology_zh":"运行使用检验 Practical performance","methodology_de":"Prüfungen der praktischen Leistungsfähigkeit","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske Prüfungen der praktischen Leistungsfähigkeit EN 14593-2:2005 EN 13274-2:2019","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou Provozní zkoušky EN 14593-2:2005 EN 13274-2:2019","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou","methodology_cs":"Provozní zkoušky"},{"_id":"6a5a55f39af9f73f38251555","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Wytrzymałość połączeń Strength of connections","methodology_en":"Strength of connections","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość połączeń Strength of connections","reference":"EN 14593-2:2005","norm_bases":["EN 14593-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Wytrzymałość połączeń Strength of connections EN 14593-2:2005 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Wytrzymalosc polaczen Strength of connections EN 14593-2:2005","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Strength of connections EN 14593-2:2005","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 连接强度 Strength of connections EN 14593-2:2005","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器","methodology_zh":"连接强度 Strength of connections","methodology_de":"Festigkeit der Verbindungen","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske Festigkeit der Verbindungen EN 14593-2:2005","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou Pevnost spojů EN 14593-2:2005","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou","methodology_cs":"Pevnost spojů"},{"_id":"6a5a55f39af9f73f38251556","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Palność Flammability","methodology_en":"Flammability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Palność Flammability","reference":"EN 14593-2:2005 EN 13274-4:2020","norm_bases":["EN 14593-2:2005 EN 13274-4:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Palność Flammability EN 14593-2:2005 EN 13274-4:2020 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Palnosc Flammability EN 14593-2:2005 EN 13274-4:2020","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Flammability EN 14593-2:2005 EN 13274-4:2020","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 可燃性 Flammability EN 14593-2:2005 EN 13274-4:2020","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器","methodology_zh":"可燃性 Flammability","methodology_de":"Entflammbarkeit","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske Entflammbarkeit EN 14593-2:2005 EN 13274-4:2020","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou Hořlavost EN 14593-2:2005 EN 13274-4:2020","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou","methodology_cs":"Hořlavost"},{"_id":"6a5a55f39af9f73f38251557","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Przeciek wewnętrzny Inward leakage","methodology_en":"Inward leakage Inward leakage","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przeciek wewnętrzny Inward leakage","reference":"EN 14593-2:2005 EN 13274-1:2001","norm_bases":["EN 14593-2:2005 EN 13274-1:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Przeciek wewnętrzny Inward leakage EN 14593-2:2005 EN 13274-1:2001 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Przeciek wewnetrzny Inward leakage EN 14593-2:2005 EN 13274-1:2001","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Inward leakage Inward leakage EN 14593-2:2005 EN 13274-1:2001","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 向内泄漏 EN 14593-2:2005 EN 13274-1:2001","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器","methodology_de":"Innenleckage","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske Innenleckage EN 14593-2:2005 EN 13274-1:2001","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske","methodology_zh":"向内泄漏","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou Průnik dovnitř EN 14593-2:2005 EN 13274-1:2001","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou","methodology_cs":"Průnik dovnitř"},{"_id":"6a5a55f39af9f73f38251558","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Opór oddychania Breathing resistance","methodology_en":"Breathing resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór oddychania Breathing resistance","reference":"EN 14593-2:2005 EN 13274-3:2001","norm_bases":["EN 14593-2:2005 EN 13274-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Opór oddychania Breathing resistance EN 14593-2:2005 EN 13274-3:2001 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Opor oddychania Breathing resistance EN 14593-2:2005 EN 13274-3:2001","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Breathing resistance EN 14593-2:2005 EN 13274-3:2001","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 呼吸阻力 Breathing resistance EN 14593-2:2005 EN 13274-3:2001","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器","methodology_zh":"呼吸阻力 Breathing resistance","methodology_de":"Atemwiderstand","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske Atemwiderstand EN 14593-2:2005 EN 13274-3:2001","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou Dýchací odpor EN 14593-2:2005 EN 13274-3:2001","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou","methodology_cs":"Dýchací odpor"},{"_id":"6a5a55f39af9f73f38251559","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air","methodology_en":"Carbon dioxide content of the inhalation air Carbon dioxide content of the inhalation air","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air","reference":"EN 14593-2:2005","norm_bases":["EN 14593-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Zawartość dwutlenku węgla w powietrzu wdychanym Carbon dioxide content of the inhalation air EN 14593-2:2005 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Zawartosc dwutlenku wegla w powietrzu wdychanym Carbon dioxide content of the inhalation air EN 14593-2:2005","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Carbon dioxide content of the inhalation air Carbon dioxide content of the inhalation air EN 14593-2:2005","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 吸入气中二氧化碳含量 EN 14593-2:2005","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器","methodology_de":"Kohlendioxidgehalt der Einatemluft","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske Kohlendioxidgehalt der Einatemluft EN 14593-2:2005","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske","methodology_zh":"吸入气中二氧化碳含量","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou Obsah oxidu uhličitého ve vdechovaném vzduchu EN 14593-2:2005","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou","methodology_cs":"Obsah oxidu uhličitého ve vdechovaném vzduchu"},{"_id":"6a5a55f39af9f73f3825155a","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","test_object_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure","methodology":"Odporność termiczna Resistance to temperature","methodology_en":"Resistance to temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność termiczna Resistance to temperature","reference":"EN 14593-2:2005","norm_bases":["EN 14593-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty wężowe sprężonego powietrza z automatem oddechowym Aparaty nadciśnieniowe z półmaską Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Odporność termiczna Resistance to temperature EN 14593-2:2005 Aparaty wezowe sprezonego powietrza z automatem oddechowym Aparaty nadcisnieniowe z polmaska Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Odpornosc termiczna Resistance to temperature EN 14593-2:2005","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Compressed air line breathing apparatus with demand valve Apparatus with a half mask at positive pressure Resistance to temperature EN 14593-2:2005","search_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器 耐温度性 Resistance to temperature EN 14593-2:2005","test_object_zh":"带需求阀的压缩空气长管呼吸器 配半面罩的正压呼吸器","methodology_zh":"耐温度性 Resistance to temperature","methodology_de":"Temperaturbeständigkeit","search_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske Temperaturbeständigkeit EN 14593-2:2005","test_object_de":"Druckluft-Schlauchgeräte mit Lungenautomat Überdruckgeräte mit Halbmaske","search_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou Tepelná odolnost EN 14593-2:2005","test_object_cs":"Hadicové dýchací přístroje na stlačený vzduch s plicní automatikou Přetlakové přístroje s polomaskou","methodology_cs":"Tepelná odolnost"},{"_id":"6a5a55f39af9f73f3825155b","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Masa Mass","methodology_en":"Mass","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa Mass","reference":"EN 14435:2004","norm_bases":["EN 14435:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Masa Mass EN 14435:2004 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Masa Mass EN 14435:2004","categories":["environment"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Mass EN 14435:2004","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 质量 EN 14435:2004","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器","methodology_de":"Masse","search_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt Masse EN 14435:2004","test_object_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt","methodology_zh":"质量","methodology_cs":"Hmotnost","search_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem Hmotnost EN 14435:2004","test_object_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem"},{"_id":"6a5a55f39af9f73f3825155c","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Odporność termiczna Resistance to temperature","methodology_en":"Resistance to temperature","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność termiczna Resistance to temperature","reference":"EN 14435:2004 EN 13274-5:2001","norm_bases":["EN 14435:2004 EN 13274-5:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Odporność termiczna Resistance to temperature EN 14435:2004 EN 13274-5:2001 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Odpornosc termiczna Resistance to temperature EN 14435:2004 EN 13274-5:2001","categories":["environment"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Resistance to temperature EN 14435:2004 EN 13274-5:2001","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 耐温度性 Resistance to temperature EN 14435:2004 EN 13274-5:2001","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器","methodology_zh":"耐温度性 Resistance to temperature","methodology_de":"Temperaturbeständigkeit","search_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt Temperaturbeständigkeit EN 14435:2004 EN 13274-5:2001","test_object_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt","methodology_cs":"Tepelná odolnost","search_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem Tepelná odolnost EN 14435:2004 EN 13274-5:2001","test_object_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem"},{"_id":"6a5a55f39af9f73f3825155d","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Wytrzymałość połączeń Strength of connections","methodology_en":"Strength of connections","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość połączeń Strength of connections","reference":"EN 14435:2004","norm_bases":["EN 14435:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Wytrzymałość połączeń Strength of connections EN 14435:2004 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Wytrzymalosc polaczen Strength of connections EN 14435:2004","categories":["environment"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Strength of connections EN 14435:2004","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 连接强度 Strength of connections EN 14435:2004","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器","methodology_zh":"连接强度 Strength of connections","methodology_de":"Festigkeit der Verbindungen","search_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt Festigkeit der Verbindungen EN 14435:2004","test_object_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt","methodology_cs":"Pevnost spojů","search_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem Pevnost spojů EN 14435:2004","test_object_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem"},{"_id":"6a5a55f39af9f73f3825155e","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Badania eksploatacyjne Practical performance","methodology_en":"Practical performance testing Practical performance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania eksploatacyjne Practical performance","reference":"EN 14435:2004 EN 13274-2:2019","norm_bases":["EN 14435:2004 EN 13274-2:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Badania eksploatacyjne Practical performance EN 14435:2004 EN 13274-2:2019 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Badania eksploatacyjne Practical performance EN 14435:2004 EN 13274-2:2019","categories":["environment"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Practical performance testing Practical performance EN 14435:2004 EN 13274-2:2019","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 运行使用检验 Practical performance EN 14435:2004 EN 13274-2:2019","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器","methodology_zh":"运行使用检验 Practical performance","methodology_de":"Prüfungen der praktischen Leistungsfähigkeit","search_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt Prüfungen der praktischen Leistungsfähigkeit EN 14435:2004 EN 13274-2:2019","test_object_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt","methodology_cs":"Provozní zkoušky","search_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem Provozní zkoušky EN 14435:2004 EN 13274-2:2019","test_object_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem"},{"_id":"6a5a55f39af9f73f3825155f","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Palność Flammability","methodology_en":"Flammability","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Palność Flammability","reference":"EN 14435:2004 EN 13274-4:2020","norm_bases":["EN 14435:2004 EN 13274-4:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Palność Flammability EN 14435:2004 EN 13274-4:2020 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Palnosc Flammability EN 14435:2004 EN 13274-4:2020","categories":["environment"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Flammability EN 14435:2004 EN 13274-4:2020","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 可燃性 Flammability EN 14435:2004 EN 13274-4:2020","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器","methodology_zh":"可燃性 Flammability","methodology_de":"Entflammbarkeit","search_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt Entflammbarkeit EN 14435:2004 EN 13274-4:2020","test_object_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt","methodology_cs":"Hořlavost","search_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem Hořlavost EN 14435:2004 EN 13274-4:2020","test_object_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem"},{"_id":"6a5a55f39af9f73f38251560","lab_id":"69ad52a3de79e566650fb0db","country":"PL","accr_number":"AB 038","accr_body":"PCA","test_object":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","test_object_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only","methodology":"Opór oddychania Breathing resistance","methodology_en":"Breathing resistance","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Opór oddychania Breathing resistance","reference":"EN 14435:2004 EN 13274-3:2001","norm_bases":["EN 14435:2004 EN 13274-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparaty powietrzne butlowe ze sprężonym powietrzem wyposażone w półmaski przeznaczone do użycia tylko z nadciśnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Opór oddychania Breathing resistance EN 14435:2004 EN 13274-3:2001 Aparaty powietrzne butlowe ze sprezonym powietrzem wyposazone w polmaski przeznaczone do uzycia tylko z nadcisnieniem Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Opor oddychania Breathing resistance EN 14435:2004 EN 13274-3:2001","categories":["environment"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only Breathing resistance EN 14435:2004 EN 13274-3:2001","search_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器 呼吸阻力 Breathing resistance EN 14435:2004 EN 13274-3:2001","test_object_zh":"配半面罩、仅供正压使用的自给开路式压缩空气呼吸器","methodology_zh":"呼吸阻力 Breathing resistance","methodology_de":"Atemwiderstand","search_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt Atemwiderstand EN 14435:2004 EN 13274-3:2001","test_object_de":"Behältergeräte mit Druckluft mit Halbmaske, ausschließlich für den Überdruckbetrieb bestimmt","methodology_cs":"Dýchací odpor","search_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem Dýchací odpor EN 14435:2004 EN 13274-3:2001","test_object_cs":"Autonomní dýchací přístroje se stlačeným vzduchem s polomaskou, určené k použití pouze s přetlakem"}],"has_pdf":true}