PCA AP 235 • Poznań, Poland • 13 calibration items

Metrology & calibration

MERAZET S.A. is a calibration laboratory accredited by PCA under number AP 235 (Poznań, Poland). Its accreditation scope covers 13 calibration items in the following areas: Metrology & calibration. Calibrated items include: Clamp meters, Multimeters, Digital ammeters, Digital voltmeters. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S), Internal procedure; Direct method Clamp measurement; At permanent l…, Internal procedure; Direct method Calibration in a temperature cali….

At a glance

  • Accreditation number: PCA AP 235
  • Calibration items in scope: 13
  • Types of calibrated items: 8
  • Calibration principles used: 4
  • City: Poznań, Poland
  • Valid until: 22-12-2029
Accreditation number
AP 235
Accreditation body
PCA
Address
ul. Krauthofera 36, 60-203 Poznań
City
Poznań, Poland
Valid until
22-12-2029

What this laboratory calibrates (8)

Calibration principles (4)

Certificate information

Issue date
23.12.2025
Issue no.
1
Certificate date
23.12.2025
Accreditation cycle
23.12.2025 — 22.12.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (13)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand. In other cases the CMC uncertainty is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Multimeters
Digital voltmeters
Clamp meters
Calibration — DC voltage
0 mV to 200 mV · CMC 2,0 · 10⁻⁴ · U + 0,0094 mV 0,2 V to 2 V · CMC 2,3 · 10⁻⁴ · U + 0,093 mV 2 V to 20 V · CMC 2,3 · 10⁻⁴ · U + 0,93 mV 20 V to 200 V · CMC 2,0 · 10⁻⁴ · U + 9,3 mV 200 V to 1000 V · CMC 2,0 · 10⁻⁴ · U + 47 mV
DC voltage
Internal procedure; Direct method; At permanent location (S) PP.1 based on EURAMET cg-15 v. 3.0; PP.2 based on EURAMET cg-15 v. 3.0
2 Multimeters
Digital voltmeters
Calibration — AC voltage
50 Hz — 20mV to 200mV · CMC 6,0 · 10⁻⁴ · U + 0,088 mV 50 Hz — 200mV to 2V · CMC 5,6 · 10⁻⁴ · U + 0,35 mV 50 Hz — 2V to 20V · CMC 5,5 · 10⁻⁴ · U + 3,0 mV 50 Hz — 20V to 200V · CMC 5,0 · 10⁻⁴ · U + 31 mV 50 Hz — 200V to 1000V · CMC 5,0 · 10⁻⁴ · U + 0,20 V
AC voltage
Internal procedure; Direct method; At permanent location (S) PP.1 based on EURAMET cg-15 v. 3.0
3 Clamp meters Calibration — AC voltage
1 kHz — 20mV to 200mV · CMC 1,1 · 10⁻³ · U + 0,17 mV 1 kHz — 200mV to 2V · CMC 1,1 · 10⁻³ · U + 0,60 mV 1 kHz — 2V to 20V · CMC 1,1 · 10⁻³ · U + 5,0 mV 1 kHz — 20V to 200V · CMC 1,1 · 10⁻³ · U + 51 mV 1 kHz — 200V to 1000V · CMC 1,1 · 10⁻³ · U + 0,31 V
AC voltage
Internal procedure; Direct method; At permanent location (S) PP.2 based on EURAMET cg-15 v. 3.0
4 Multimeters
Digital ammeters
Clamp meters
Calibration — DC current
0 mA to 20 mA · CMC 3,0 · 10⁻⁴ · I + 0,0014 mA 20 mA to 200 mA · CMC 3,0 · 10⁻⁴ · I + 0,017 mA 0,2 A to 2 A · CMC 3,3 · 10⁻⁴ · I + 0,15 mA 2 A to 10 A · CMC 3,0 · 10⁻⁴ · I + 1,8 mA 10A to 19A · CMC 3,0 · 10⁻⁴ · I + 1,5 mA
DC current
Internal procedure; Direct method; At permanent location (S) PP.1 based on EURAMET cg-15 v. 3.0; PP.2 based on EURAMET cg-15 v. 3.0
5 Clamp meters Calibration — DC current
5 A to 50 A · CMC 1,0 · 10⁻⁴ · I + 58 mA 50 A to 1000 A · CMC 3,0 · 10⁻⁴ · I + 0,11 A
DC current
Internal procedure; Direct method Clamp measurement; At permanent location (S) PP.2
6 Multimeters
Digital ammeters
Calibration — AC current
50 Hz — 2 mA to 20 mA · CMC 4,4 · 10⁻⁴ · I + 0,0095 mA 50 Hz — 20 mA to 200 mA · CMC 3,9 · 10⁻⁴ · I + 0,085 mA 50 Hz — 0,2 A to 2 A · CMC 4,1 · 10⁻⁴ · I + 0,78 mA 50 Hz — 2 A to 10 A · CMC 2,8 · 10⁻⁴ · I + 10 mA 1 kHz — 2 mA to 20 mA · CMC 1,1 · 10⁻³ · I + 0,012 mA
AC current
Internal procedure; Direct method; At permanent location (S) PP.1 based on EURAMET cg-15 v. 3.0
7 Clamp meters Calibration — AC current
1 kHz — 20 mA to 200 mA · CMC 1,0 · 10⁻³ · I + 0,092 mA 1 kHz — 0,2 A to 2 A · CMC 1,0 · 10⁻³ · I + 0,80 mA 1 kHz — 2 A to 6 A · CMC 8,0 · 10⁻⁴ · I + 9,9 mA
AC current
Internal procedure; Direct method; At permanent location (S) PP.2 based on EURAMET cg-15 v. 3.0
8 Clamp meters Calibration — AC current
50 Hz — 5 A to 50 A · CMC 2,0 · 10⁻⁴ · I + 71 mA 50 Hz — 50 A to 1000 A · CMC 4,0 · 10⁻⁴ · I + 0,51 A
AC current
Internal procedure; Direct method Clamp measurement; At permanent location (S) PP.2
9 Multimeters
Digital ohmmeters
Clamp meters
Calibration — DC resistance
0,01 Ω to 0,1 Ω · CMC 5,0 · 10⁻⁵ · R + 0,060 mΩ 0,1 Ω to 1 Ω · CMC 5,4 · 10⁻⁴ · R + 0,030 mΩ 1 Ω to 10 Ω · CMC 1,2 · 10⁻⁴ · R + 0,020 mΩ 10 Ω to 100 Ω · CMC 5,8 · 10⁻⁴ · R + 0,030 mΩ 100 Ω to 1000 Ω · CMC 6,0 · 10⁻⁴ · R + 0,30 mΩ 1 kΩ to 10 kΩ · CMC 5,8 · 10⁻⁴ · R + 0,0030 mΩ 10 kΩ to 100 kΩ · CMC 0,52% 100 kΩ to 1000 kΩ · CMC 0,52% 1 MΩ to 10 MΩ · CMC 0,65% 10 MΩ to 100 MΩ · CMC 0,90% 100 MΩ to 1000 MΩ · CMC 0,90%
DC resistance
Internal procedure; Direct method; At permanent location (S) PP.1 based on EURAMET cg-15 v. 3.0; PP.2 based on EURAMET cg-15 v. 3.0
10 Insulation resistance meters Calibration — DC resistance
up to 1kV — 50 kΩ to 1 GΩ · CMC 0,9% from 1kV to 5kV — 50 kΩ to 1 TΩ · CMC 2,0%
DC resistance
Internal procedure; Direct method; At permanent location (S) PP.3
11 Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry)
-25 °C to 150 °C · CMC 0,13 °C 150 °C to 400 °C · CMC 0,38 °C 400 °C to 650 °C · CMC 0,56 °C
Temperature (electrical thermometry)
Internal procedure; Direct method Calibration in a temperature calibrator; At permanent location (S) PP.4
12 Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry)
-30 °C to 0 °C · CMC 0,6 °C 0 °C to 50 °C · CMC 0,4 °C 50 °C to 150 °C · CMC 0,5 °C
Temperature (electrical thermometry)
Internal procedure; Direct method Calibration in a thermostatic chamber; At permanent location (S) PP.5
13 Pyrometers (including thermal imaging cameras) Calibration — Temperature (radiation thermometry)
-15°C to 120°C · CMC 0,8 °C 120°C to 200°C · CMC 1,1 °C 200°C to 500°C · CMC 2,4 °C
Temperature (radiation thermometry)
Internal procedure; Direct method; At permanent location (S) PP.7

Reference standards (7)

EURAMET cg-15 v. 3.0
PP.1
PP.2
PP.3
PP.4
PP.5
PP.7