🇵🇱 Centralne Laboratorium Pomiarowo-Badawcze Sp. z o.o. PL
Metrology & calibration
Centralne Laboratorium Pomiarowo-Badawcze Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 230 (Jastrzębie Zdrój, Poland). Its accreditation scope covers 8 calibration items in the following areas: Metrology & calibration. Calibrated items include: Dust meters, Electronic non-automatic weighing instruments, Graduated measuring cylinders, Graduated pipettes. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P).
At a glance
- Accreditation number: PCA AP 230
- Calibration items in scope: 8
- Types of calibrated items: 8
- Calibration principles used: 2
- City: Jastrzębie Zdrój, Poland
- Valid until: 25-05-2029
- Accreditation number
- AP 230
- Accreditation body
- PCA
- Address
- ul. Rybnicka 6, 44-335 Jastrzębie Zdrój
- City
- Jastrzębie Zdrój, Poland
- Valid until
- 25-05-2029
What this laboratory calibrates (8)
- Dust meters — 1 calibration item
- Electronic non-automatic weighing instruments — 1 calibration item
- Graduated measuring cylinders — 1 calibration item
- Graduated pipettes — 1 calibration item
- One-mark glass volumetric flasks — 1 calibration item
- One-mark pipettes — 1 calibration item
- Ordinary burettes — 1 calibration item
- Piston pipettes — 1 calibration item
Calibration principles (2)
- Internal procedure; At permanent location (S) — 7 calibration items
- Internal procedure; At permanent location (S) and outside of it (P) — 1 calibration item
Certificate information
- Issue date
- 26.05.2025
- Issue no.
- 1
- Certificate date
- 26.05.2025
- Accreditation cycle
- 26.05.2025 — 25.05.2029
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (8)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Dust meters | Calibration — Volume flow rate (flow - gases) 9,00 dm³/min to 11,00 dm³/min · CMC 0,23 dm³/min Volume flow rate (flow - gases) |
Internal procedure; At permanent location (S) | PW-04 | |
| 2 | Electronic non-automatic weighing instruments | Calibration — Mass (weighing instruments) up to 20 g · CMC 1,6·10⁻⁶ % from 20 g to 200 g · CMC 2,5·10⁻⁶ % from 200 g to 5 kg · CMC 6,3·10⁻⁶ % Mass (weighing instruments) |
Internal procedure; At permanent location (S) and outside of it (P) | PW-01 based on EURAMET cg-18 v. 4.0 | |
| 3 | Ordinary burettes | Calibration — Volume 100 ml · CMC 0,083 ml 50 ml · CMC 0,048 ml 25 ml · CMC 0,048 ml 10 ml · CMC 0,048 ml 5 ml · CMC 0,048 ml Volume |
Internal procedure; At permanent location (S) | PW-03 based on PN-EN ISO 4787:2022-06 | |
| 4 | Graduated measuring cylinders | Calibration — Volume 100 ml · CMC 0,41 ml 50 ml · CMC 0,21 ml 25 ml · CMC 0,21 ml 15 ml · CMC 0,21 ml 10 ml · CMC 0,21 ml Volume |
Internal procedure; At permanent location (S) | PW-03 based on PN-EN ISO 4787:2022-06 | |
| 5 | One-mark glass volumetric flasks | Calibration — Volume 100 ml · CMC 0,025 ml 50 ml · CMC 0,018 ml 25 ml · CMC 0,017 ml 20 ml · CMC 0,007 ml 10 ml · CMC 0,007 ml Volume |
Internal procedure; At permanent location (S) | PW-03 based on PN-EN ISO 4787:2022-06 | |
| 6 | One-mark pipettes | Calibration — Volume 50 ml to 100 ml · CMC 0,052 ml 25 ml to 50 ml · CMC 0,035 ml 20 ml to 25 ml · CMC 0,027 ml 10 ml to 20 ml · CMC 0,013 ml 5 ml to 10 ml · CMC 0,013 ml 2 ml to 5 ml · CMC 0,013 ml 1 ml to 2 ml · CMC 0,0041 ml 0,5 ml to 1 ml · CMC 0,0031 ml 0,5 ml · CMC 0,0028 ml Volume |
Internal procedure; At permanent location (S) | PW-03 based on PN-EN ISO 4787:2022-06 | |
| 7 | Graduated pipettes | Calibration — Volume 20 ml to 25 ml · CMC 0,045 ml 15 ml to 20 ml · CMC 0,045 ml 10 ml to 15 ml · CMC 0,045 ml 5 ml to 10 ml · CMC 0,045 ml 2 ml to 5 ml · CMC 0,045 ml 1 ml to 2 ml · CMC 0,010 ml 0,5 ml to 1 ml · CMC 0,0050 ml 0,5 ml · CMC 0,0043 ml Volume |
Internal procedure; At permanent location (S) | PW-03 based on PN-EN ISO 4787:2022-06 | |
| 8 | Piston pipettes | Calibration — Volume 0,1 μl do 1 μl · CMC 0,025 μl 1 μl do 5 μl · CMC 0,032 μl 5 μl do 10 μl · CMC 0,037 μl 10 μl do 20 μl · CMC 0,049 μl 20 μl do 50 μl · CMC 0,28 μl 50 μl do 100 μl · CMC 0,37 μl 100 μl do 250 μl · CMC 0,93 μl 250 μl do 500 μl · CMC 1,3 μl 500 μl to 1000 μl · CMC 2,2 μl 1000 μl to 2500 μl · CMC 13 μl 2500 μl to 5000 μl · CMC 16 μl 5000 μl do 7500 μl · CMC 18 μl 7500 μl do 10000 μl · CMC 22 μl Volume |
Internal procedure; At permanent location (S) | PW- 02 based on PN-EN ISO 8655-6:2022-11 | |
Reference standards (7)
EURAMET cg-18 v. 4.0
PN-EN ISO 4787:2022-06
PN-EN ISO 8655-6:2022-11
PW- 02
PW-01
PW-03