🇵🇱 Centralne Laboratorium Pomiarowo-Badawcze Sp. z o.o. PL

PCA AP 230 • Jastrzębie Zdrój, Poland • 8 calibration items

Metrology & calibration

Centralne Laboratorium Pomiarowo-Badawcze Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 230 (Jastrzębie Zdrój, Poland). Its accreditation scope covers 8 calibration items in the following areas: Metrology & calibration. Calibrated items include: Dust meters, Electronic non-automatic weighing instruments, Graduated measuring cylinders, Graduated pipettes. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P).

At a glance

  • Accreditation number: PCA AP 230
  • Calibration items in scope: 8
  • Types of calibrated items: 8
  • Calibration principles used: 2
  • City: Jastrzębie Zdrój, Poland
  • Valid until: 25-05-2029
Accreditation number
AP 230
Accreditation body
PCA
Address
ul. Rybnicka 6, 44-335 Jastrzębie Zdrój
City
Jastrzębie Zdrój, Poland
Valid until
25-05-2029

What this laboratory calibrates (8)

Calibration principles (2)

Certificate information

Issue date
26.05.2025
Issue no.
1
Certificate date
26.05.2025
Accreditation cycle
26.05.2025 — 25.05.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (8)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand. In other cases the CMC uncertainty is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Dust meters Calibration — Volume flow rate (flow - gases)
9,00 dm³/min to 11,00 dm³/min · CMC 0,23 dm³/min
Volume flow rate (flow - gases)
Internal procedure; At permanent location (S) PW-04
2 Electronic non-automatic weighing instruments Calibration — Mass (weighing instruments)
up to 20 g · CMC 1,6·10⁻⁶ % from 20 g to 200 g · CMC 2,5·10⁻⁶ % from 200 g to 5 kg · CMC 6,3·10⁻⁶ %
Mass (weighing instruments)
Internal procedure; At permanent location (S) and outside of it (P) PW-01 based on EURAMET cg-18 v. 4.0
3 Ordinary burettes Calibration — Volume
100 ml · CMC 0,083 ml 50 ml · CMC 0,048 ml 25 ml · CMC 0,048 ml 10 ml · CMC 0,048 ml 5 ml · CMC 0,048 ml
Volume
Internal procedure; At permanent location (S) PW-03 based on PN-EN ISO 4787:2022-06
4 Graduated measuring cylinders Calibration — Volume
100 ml · CMC 0,41 ml 50 ml · CMC 0,21 ml 25 ml · CMC 0,21 ml 15 ml · CMC 0,21 ml 10 ml · CMC 0,21 ml
Volume
Internal procedure; At permanent location (S) PW-03 based on PN-EN ISO 4787:2022-06
5 One-mark glass volumetric flasks Calibration — Volume
100 ml · CMC 0,025 ml 50 ml · CMC 0,018 ml 25 ml · CMC 0,017 ml 20 ml · CMC 0,007 ml 10 ml · CMC 0,007 ml
Volume
Internal procedure; At permanent location (S) PW-03 based on PN-EN ISO 4787:2022-06
6 One-mark pipettes Calibration — Volume
50 ml to 100 ml · CMC 0,052 ml 25 ml to 50 ml · CMC 0,035 ml 20 ml to 25 ml · CMC 0,027 ml 10 ml to 20 ml · CMC 0,013 ml 5 ml to 10 ml · CMC 0,013 ml 2 ml to 5 ml · CMC 0,013 ml 1 ml to 2 ml · CMC 0,0041 ml 0,5 ml to 1 ml · CMC 0,0031 ml 0,5 ml · CMC 0,0028 ml
Volume
Internal procedure; At permanent location (S) PW-03 based on PN-EN ISO 4787:2022-06
7 Graduated pipettes Calibration — Volume
20 ml to 25 ml · CMC 0,045 ml 15 ml to 20 ml · CMC 0,045 ml 10 ml to 15 ml · CMC 0,045 ml 5 ml to 10 ml · CMC 0,045 ml 2 ml to 5 ml · CMC 0,045 ml 1 ml to 2 ml · CMC 0,010 ml 0,5 ml to 1 ml · CMC 0,0050 ml 0,5 ml · CMC 0,0043 ml
Volume
Internal procedure; At permanent location (S) PW-03 based on PN-EN ISO 4787:2022-06
8 Piston pipettes Calibration — Volume
0,1 μl do 1 μl · CMC 0,025 μl 1 μl do 5 μl · CMC 0,032 μl 5 μl do 10 μl · CMC 0,037 μl 10 μl do 20 μl · CMC 0,049 μl 20 μl do 50 μl · CMC 0,28 μl 50 μl do 100 μl · CMC 0,37 μl 100 μl do 250 μl · CMC 0,93 μl 250 μl do 500 μl · CMC 1,3 μl 500 μl to 1000 μl · CMC 2,2 μl 1000 μl to 2500 μl · CMC 13 μl 2500 μl to 5000 μl · CMC 16 μl 5000 μl do 7500 μl · CMC 18 μl 7500 μl do 10000 μl · CMC 22 μl
Volume
Internal procedure; At permanent location (S) PW- 02 based on PN-EN ISO 8655-6:2022-11

Reference standards (7)

EURAMET cg-18 v. 4.0
PN-EN ISO 4787:2022-06
PN-EN ISO 8655-6:2022-11
PW- 02
PW-01
PW-03
PW-04

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20230