🇵🇱 RATEART Dariusz Matyjewicz Spółka Komandytowa PL

PCA AP 210 • Łódź, Poland • 7 calibration items

Metrology & calibration

RATEART Dariusz Matyjewicz Spółka Komandytowa is a calibration laboratory accredited by PCA under number AP 210 (Łódź, Poland). Its accreditation scope covers 7 calibration items in the following areas: Metrology & calibration. Calibrated items include: Single-mode optical time-domain reflectometers, Optical power (power level) meters, Optical radiation sources, Multimode optical time-domain reflectometers. Most frequently used calibration principles: Internal procedure; Optical length measurement; At permanent locati…, Internal procedure; Optical power level measurement; At permanent l…, Internal procedure; Central wavelength measurement; At permanent lo….

At a glance

  • Accreditation number: PCA AP 210
  • Calibration items in scope: 7
  • Types of calibrated items: 5
  • Calibration principles used: 5
  • City: Łódź, Poland
  • Valid until: 25-07-2030
Accreditation number
AP 210
Accreditation body
PCA
Address
ul. Lenartowicza 24, 93-143 Łódź
City
Łódź, Poland
Division
RATEART Calibration Laboratory
Valid until
25-07-2030

What this laboratory calibrates (5)

Calibration principles (5)

Certificate information

Issue date
29.06.2026
Issue no.
7
Certificate date
26.07.2022
Accreditation cycle
29.06.2026 — 25.07.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (7)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Transmitters in transmission analysers Calibration — Frequency
bit rates: — 2 Mbit/s to 100 Gbit/s · CMC 0,00004 %
Frequency
Internal procedure; Measurement of nominal frequency deviation Direct method; At permanent location (S) PW-05
2 Single-mode optical time-domain reflectometers Calibration — Optoelectronic quantities
wavelength 1310 nm: — 2346 m · CMC 0,046 m wavelength 1383 nm: — 2346 m · CMC 0,084 m wavelength 1490 nm: — 2346 m · CMC 0,166 m wavelength 1550 nm: — 2347 m · CMC 0,212 m wavelength 1625 nm: — 2347 m · CMC 0,268 m wavelength 1650 nm: — 2348 m · CMC 0,288 m
Optoelectronic quantities
Internal procedure; Optical length measurement; At permanent location (S) and outside of it (P) PW-01
3 Multimode optical time-domain reflectometers Calibration — Optoelectronic quantities
wavelength 850 nm: — 109,50 m · CMC 0,12 m wavelength 1300 nm: — 109,07 m · CMC 0,08 m
Optoelectronic quantities
Internal procedure; Optical length measurement; At permanent location (S) and outside of it (P) PW-02
4 Optical radiation sources
Single-mode optical time-domain reflectometers
Calibration — Optoelectronic quantities
wavelength 1310 nm: — -50 dBm to 5 dBm · CMC 5,28 % wavelength 1550 nm: — -50 dBm to 5 dBm · CMC 5,30 % wavelength 1625 nm: — -50 dBm to 5 dBm · CMC 5,28 %
Optoelectronic quantities
Internal procedure; Optical power level measurement; At permanent location (S) and outside of it (P) PW-01, PW-04 based on PN-EN 61280-1-1:2013-10
5 Optical radiation sources
Single-mode optical time-domain reflectometers
Calibration — Optoelectronic quantities
1310 nm · CMC 0,002 nm 1500 nm to 1640 nm · CMC 0,002 nm
Optoelectronic quantities
Internal procedure; Central wavelength measurement; At permanent location (S) and outside of it (P) PW-01, PW-04 based on PN-EN IEC 61280-1-3: 2022-04
6 Optical power (power level) meters Calibration — Optoelectronic quantities
wavelength 1310 nm: — -50 dBm to 5 dBm · CMC 2,44 % wavelength 1490 nm: — -50 dBm to 5 dBm · CMC 2,46 % wavelength 1550 nm: — -50 dBm to 5 dBm · CMC 2,44 % wavelength 1625 nm: — -50 dBm to 5 dBm · CMC 2,44 %
Optoelectronic quantities
Internal procedure; Optical power level measurement; At permanent location (S) and outside of it (P) PW-03 based on PN-EN IEC 61315:2019-10
7 Optical power (power level) meters Calibration — Optoelectronic quantities
wavelength 1310 nm: — -50 dBm to 5 dBm · CMC 0,72 % wavelength 1490 nm: — -50 dBm to 5 dBm · CMC 0,72 % wavelength 1550 nm: — -50 dBm to 5 dBm · CMC 0,72 % wavelength 1625 nm: — -50 dBm to 5 dBm · CMC 0,72 %
Optoelectronic quantities
Internal procedure; Optical power non-linearity measurement; At permanent location (S) and outside of it (P) PW-03 based on standard PN-EN IEC 61315:2019-10

Reference standards (8)

PN-EN 61280-1-1:2013-10
PN-EN IEC 61280-1-3: 2022-04
PN-EN IEC 61315:2019-10
PW-01
PW-02
PW-03
PW-04
PW-05