{"lab":{"_id":"6af798980ecd48de0c7068a7","accr_number":"AP 210","country":"PL","imported_at":"2026-11-13T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Lenartowicza 24, 93-143 Łódź","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"26.07.2022","city":"Łódź","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.","cycle_from":"29.06.2026","cycle_to":"25.07.2030","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"10.02","pl":"częstotliwość","en":"frequency","de":"Frequenz","zh":"频率","cs":"frekvence"},{"codes":"16.01","pl":"wielkości optoelektroniczne","en":"optoelectronic quantities","de":"optoelektronische Größen","zh":"光电量","cs":"optoelektronické veličiny"}],"has_en":true,"has_zh":true,"issue":{"no":"7","date":"29.06.2026"},"issue_date":"29.06.2026","issue_number":"7","lab_division":"Laboratorium wzorcujące RATEART","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[19.4854289,51.7369886]},"map_coord":[51.7369886,19.4854289],"map_geo":"nominatim-street","methods_count":7,"name":"RATEART Dariusz Matyjewicz Spółka Komandytowa","parse_date":"2026-11-13T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-13T12:00:00.000Z","pdf_files":["AP_210.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: częstotliwość, wielkości optoelektroniczne. W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"rateart dariusz matyjewicz spółka komandytowa laboratorium wzorcujące rateart ul. lenartowicza 24, 93-143 łódź laboratorium wzorcujące. wielkości mierzone: częstotliwość, wielkości optoelektroniczne. w stałej lokalizacji (s) i/lub poza nią (p). ap 210 ap210 laboratorium wzorcujące wzorcowanie kalibracja frequency optoelectronic quantities rateart dariusz matyjewicz spolka komandytowa laboratorium wzorcujace rateart ul. lenartowicza 24, 93-143 lodz laboratorium wzorcujace. wielkosci mierzone: czestotliwosc, wielkosci optoelektroniczne. w stalej lokalizacji (s) i/lub poza nia (p). ap 210 ap210 laboratorium wzorcujace wzorcowanie kalibracja frequency optoelectronic quantities","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20210,podmiot.html","source_pdf_sha256":"2aeba44f19ab0c62653edcb11c4a66770835e3711154e3409627fd4d0b360ca3","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/13/fe4d556a9316ee83d6486f4746fa33eb/AP%20210.pdf","status":"active","updated_at":"2026-11-13T12:00:00.000Z","valid_from":"26-07-2022","valid_until":"25-07-2030","website":"www.rateart.pl","lab_division_en":"RATEART Calibration Laboratory","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Kalibrierlaboratorium RATEART","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"RATEART 校准实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Kalibrační laboratoř RATEART","pelny_cs":true},"methods":[{"_id":"5041f3a8f896637e0ec0d08d","lab_id":"6af798980ecd48de0c7068a7","country":"PL","accr_number":"AP 210","accr_body":"PCA","test_object":"Nadajniki w analizatorach transmisji","test_object_en":"Transmitters in transmission analysers","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"przepływności:","range":"2 Mbit/s do 100 Gbit/s","cmc":"0,00004 %"}],"parameters_en":[{"name":"bit rates:","range":"2 Mbit/s to 100 Gbit/s","cmc":"0,00004 %"}],"technique":"Procedura wewnętrzna; Pomiar odchylenia częstotliwości nominalnej\nMetoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Measurement of nominal frequency deviation\nDirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Pomiar odchylenia częstotliwości nominalnej\nMetoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Measurement of nominal frequency deviation\nDirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\nprzepływności: 2 Mbit/s do 100 Gbit/s CMC 0,00004 %\nProcedura wewnętrzna; Pomiar odchylenia częstotliwości nominalnej\nMetoda bezpośrednia; W stałej lokalizacji (S)","reference":"PW-05","norm_bases":["PW-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Nadajniki w analizatorach transmisji Wzorcowanie — Częstotliwość\nprzepływności: 2 Mbit/s do 100 Gbit/s CMC 0,00004 %\nProcedura wewnętrzna; Pomiar odchylenia częstotliwości nominalnej\nMetoda bezpośrednia; W stałej lokalizacji (S) PW-05 Nadajniki w analizatorach transmisji Wzorcowanie — Czestotliwosc\nprzeplywnosci: 2 Mbit/s do 100 Gbit/s CMC 0,00004 %\nProcedura wewnetrzna; Pomiar odchylenia czestotliwosci nominalnej\nMetoda bezposrednia; W stalej lokalizacji (S) PW-05","search_en":"Transmitters in transmission analysers Calibration — Frequency Internal procedure; Measurement of nominal frequency deviation Direct method; At permanent location (S) Frequency Internal procedure Measurement of nominal frequency deviation Direct method At permanent location (S) bit rates: PW-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"Bitraten:","range":"2 Mbit/s to 100 Gbit/s","cmc":"0,00004 %"}],"regulatory_area_de":"Frequenz","search_de":"Sender in Übertragungsanalysatoren Kalibrierung — Frequenz Interne Verfahrensanweisung; Messung der Abweichung von der Nennfrequenz Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Messung der Abweichung von der Nennfrequenz Direktes Verfahren Am festen Standort (S) Bitraten: PW-05","technique_de":"Interne Verfahrensanweisung; Messung der Abweichung von der Nennfrequenz\nDirektes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung der Abweichung von der Nennfrequenz\nDirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Sender in Übertragungsanalysatoren","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"比特率：","range":"2 Mbit/s to 100 Gbit/s","cmc":"0,00004 %"}],"regulatory_area_zh":"频率","search_zh":"传输分析仪中的发射机 校准 — 频率 内部程序；标称频率偏差测量 直接法；在固定地点 (S) 频率 内部程序 标称频率偏差测量 直接法 在固定地点 (S) 比特率： PW-05","technique_zh":"内部程序；标称频率偏差测量\n直接法；在固定地点 (S)","techniques_zh":["内部程序","标称频率偏差测量\n直接法","在固定地点 (S)"],"test_object_zh":"传输分析仪中的发射机","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"přenosové rychlosti:","range":"2 Mbit/s to 100 Gbit/s","cmc":"0,00004 %"}],"regulatory_area_cs":"Frekvence","search_cs":"Vysílače v analyzátorech přenosu Kalibrace — Kmitočet Vnitřní postup; Měření odchylky jmenovitého kmitočtu Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Měření odchylky jmenovitého kmitočtu Přímá metoda Ve stálé lokalitě (S) přenosové rychlosti: PW-05","technique_cs":"Vnitřní postup; Měření odchylky jmenovitého kmitočtu\nPřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Měření odchylky jmenovitého kmitočtu\nPřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Vysílače v analyzátorech přenosu"},{"_id":"9e295c479a78b330a33d6679","lab_id":"6af798980ecd48de0c7068a7","country":"PL","accr_number":"AP 210","accr_body":"PCA","test_object":"Reflektometry światłowodowe jednomodowe","test_object_en":"Single-mode optical time-domain reflectometers","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 1310 nm:","range":"2346 m","cmc":"0,046 m"},{"name":"długość fali 1383 nm:","range":"2346 m","cmc":"0,084 m"},{"name":"długość fali 1490 nm:","range":"2346 m","cmc":"0,166 m"},{"name":"długość fali 1550 nm:","range":"2347 m","cmc":"0,212 m"},{"name":"długość fali 1625 nm:","range":"2347 m","cmc":"0,268 m"},{"name":"długość fali 1650 nm:","range":"2348 m","cmc":"0,288 m"}],"parameters_en":[{"name":"wavelength 1310 nm:","range":"2346 m","cmc":"0,046 m"},{"name":"wavelength 1383 nm:","range":"2346 m","cmc":"0,084 m"},{"name":"wavelength 1490 nm:","range":"2346 m","cmc":"0,166 m"},{"name":"wavelength 1550 nm:","range":"2347 m","cmc":"0,212 m"},{"name":"wavelength 1625 nm:","range":"2347 m","cmc":"0,268 m"},{"name":"wavelength 1650 nm:","range":"2348 m","cmc":"0,288 m"}],"technique":"Procedura wewnętrzna; Pomiar długości optycznej; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Optical length measurement; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Pomiar długości optycznej","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Optical length measurement","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm: 2346 m CMC 0,046 m\ndługość fali 1383 nm: 2346 m CMC 0,084 m\ndługość fali 1490 nm: 2346 m CMC 0,166 m\ndługość fali 1550 nm: 2347 m CMC 0,212 m\ndługość fali 1625 nm: 2347 m CMC 0,268 m\ndługość fali 1650 nm: 2348 m CMC 0,288 m\nProcedura wewnętrzna; Pomiar długości optycznej; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-01","norm_bases":["PW-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Reflektometry światłowodowe jednomodowe Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm: 2346 m CMC 0,046 m\ndługość fali 1383 nm: 2346 m CMC 0,084 m\ndługość fali 1490 nm: 2346 m CMC 0,166 m\ndługość fali 1550 nm: 2347 m CMC 0,212 m\ndługość fali 1625 nm: 2347 m CMC 0,268 m\ndługość fali 1650 nm: 2348 m CMC 0,288 m\nProcedura wewnętrzna; Pomiar długości optycznej; W stałej lokalizacji (S) i poza nią (P) PW-01 Reflektometry swiatlowodowe jednomodowe Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 1310 nm: 2346 m CMC 0,046 m\ndlugosc fali 1383 nm: 2346 m CMC 0,084 m\ndlugosc fali 1490 nm: 2346 m CMC 0,166 m\ndlugosc fali 1550 nm: 2347 m CMC 0,212 m\ndlugosc fali 1625 nm: 2347 m CMC 0,268 m\ndlugosc fali 1650 nm: 2348 m CMC 0,288 m\nProcedura wewnetrzna; Pomiar dlugosci optycznej; W stalej lokalizacji (S) i poza nia (P) PW-01","search_en":"Single-mode optical time-domain reflectometers Calibration — Optoelectronic quantities Internal procedure; Optical length measurement; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Optical length measurement At permanent location (S) and outside of it (P) wavelength 1310 nm: wavelength 1383 nm: wavelength 1490 nm: wavelength 1550 nm: wavelength 1625 nm: wavelength 1650 nm: PW-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 1310 nm:","range":"2346 m","cmc":"0,046 m"},{"name":"Wellenlänge 1383 nm:","range":"2346 m","cmc":"0,084 m"},{"name":"Wellenlänge 1490 nm:","range":"2346 m","cmc":"0,166 m"},{"name":"Wellenlänge 1550 nm:","range":"2347 m","cmc":"0,212 m"},{"name":"Wellenlänge 1625 nm:","range":"2347 m","cmc":"0,268 m"},{"name":"Wellenlänge 1650 nm:","range":"2348 m","cmc":"0,288 m"}],"regulatory_area_de":"Optoelektronische Größen","search_de":"Singlemode-Lichtwellenleiter-Reflektometer (OTDR) Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Messung der optischen Länge; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Messung der optischen Länge Am festen Standort (S) und außerhalb (P) Wellenlänge 1310 nm: Wellenlänge 1383 nm: Wellenlänge 1490 nm: Wellenlänge 1550 nm: Wellenlänge 1625 nm: Wellenlänge 1650 nm: PW-01","technique_de":"Interne Verfahrensanweisung; Messung der optischen Länge; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Messung der optischen Länge","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Singlemode-Lichtwellenleiter-Reflektometer (OTDR)","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 1310 nm：","range":"2346 m","cmc":"0,046 m"},{"name":"波长 1383 nm：","range":"2346 m","cmc":"0,084 m"},{"name":"波长 1490 nm：","range":"2346 m","cmc":"0,166 m"},{"name":"波长 1550 nm：","range":"2347 m","cmc":"0,212 m"},{"name":"波长 1625 nm：","range":"2347 m","cmc":"0,268 m"},{"name":"波长 1650 nm：","range":"2348 m","cmc":"0,288 m"}],"regulatory_area_zh":"光电量","search_zh":"单模光时域反射仪 校准 — 光电量 内部程序；光学长度测量；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 光学长度测量 在固定地点 (S) 及固定地点以外 (P) 波长 1310 nm： 波长 1383 nm： 波长 1490 nm： 波长 1550 nm： 波长 1625 nm： 波长 1650 nm： PW-01","technique_zh":"内部程序；光学长度测量；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","光学长度测量","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"单模光时域反射仪","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 1310 nm:","range":"2346 m","cmc":"0,046 m"},{"name":"vlnová délka 1383 nm:","range":"2346 m","cmc":"0,084 m"},{"name":"vlnová délka 1490 nm:","range":"2346 m","cmc":"0,166 m"},{"name":"vlnová délka 1550 nm:","range":"2347 m","cmc":"0,212 m"},{"name":"vlnová délka 1625 nm:","range":"2347 m","cmc":"0,268 m"},{"name":"vlnová délka 1650 nm:","range":"2348 m","cmc":"0,288 m"}],"regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Jednovidové optické reflektometry Kalibrace — Optoelektronické veličiny Vnitřní postup; Měření optické délky; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Měření optické délky V trvalé lokalitě (S) i mimo ni (P) vlnová délka 1310 nm: vlnová délka 1383 nm: vlnová délka 1490 nm: vlnová délka 1550 nm: vlnová délka 1625 nm: vlnová délka 1650 nm: PW-01","technique_cs":"Vnitřní postup; Měření optické délky; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Měření optické délky","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Jednovidové optické reflektometry"},{"_id":"f212bc149d42958a747cbab6","lab_id":"6af798980ecd48de0c7068a7","country":"PL","accr_number":"AP 210","accr_body":"PCA","test_object":"Reflektometry światłowodowe wielomodowe","test_object_en":"Multimode optical time-domain reflectometers","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 850 nm:","range":"109,50 m","cmc":"0,12 m"},{"name":"długość fali 1300 nm:","range":"109,07 m","cmc":"0,08 m"}],"parameters_en":[{"name":"wavelength 850 nm:","range":"109,50 m","cmc":"0,12 m"},{"name":"wavelength 1300 nm:","range":"109,07 m","cmc":"0,08 m"}],"technique":"Procedura wewnętrzna; Pomiar długości optycznej; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Optical length measurement; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Pomiar długości optycznej","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Optical length measurement","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 850 nm: 109,50 m CMC 0,12 m\ndługość fali 1300 nm: 109,07 m CMC 0,08 m\nProcedura wewnętrzna; Pomiar długości optycznej; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-02","norm_bases":["PW-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Reflektometry światłowodowe wielomodowe Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 850 nm: 109,50 m CMC 0,12 m\ndługość fali 1300 nm: 109,07 m CMC 0,08 m\nProcedura wewnętrzna; Pomiar długości optycznej; W stałej lokalizacji (S) i poza nią (P) PW-02 Reflektometry swiatlowodowe wielomodowe Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 850 nm: 109,50 m CMC 0,12 m\ndlugosc fali 1300 nm: 109,07 m CMC 0,08 m\nProcedura wewnetrzna; Pomiar dlugosci optycznej; W stalej lokalizacji (S) i poza nia (P) PW-02","search_en":"Multimode optical time-domain reflectometers Calibration — Optoelectronic quantities Internal procedure; Optical length measurement; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Optical length measurement At permanent location (S) and outside of it (P) wavelength 850 nm: wavelength 1300 nm: PW-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 850 nm:","range":"109,50 m","cmc":"0,12 m"},{"name":"Wellenlänge 1300 nm:","range":"109,07 m","cmc":"0,08 m"}],"regulatory_area_de":"Optoelektronische Größen","search_de":"Multimode-Lichtwellenleiter-Reflektometer (OTDR) Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Messung der optischen Länge; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Messung der optischen Länge Am festen Standort (S) und außerhalb (P) Wellenlänge 850 nm: Wellenlänge 1300 nm: PW-02","technique_de":"Interne Verfahrensanweisung; Messung der optischen Länge; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Messung der optischen Länge","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Multimode-Lichtwellenleiter-Reflektometer (OTDR)","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 850 nm：","range":"109,50 m","cmc":"0,12 m"},{"name":"波长 1300 nm：","range":"109,07 m","cmc":"0,08 m"}],"regulatory_area_zh":"光电量","search_zh":"多模光时域反射仪 校准 — 光电量 内部程序；光学长度测量；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 光学长度测量 在固定地点 (S) 及固定地点以外 (P) 波长 850 nm： 波长 1300 nm： PW-02","technique_zh":"内部程序；光学长度测量；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","光学长度测量","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"多模光时域反射仪","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 850 nm:","range":"109,50 m","cmc":"0,12 m"},{"name":"vlnová délka 1300 nm:","range":"109,07 m","cmc":"0,08 m"}],"regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Mnohovidové optické reflektometry Kalibrace — Optoelektronické veličiny Vnitřní postup; Měření optické délky; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Měření optické délky V trvalé lokalitě (S) i mimo ni (P) vlnová délka 850 nm: vlnová délka 1300 nm: PW-02","technique_cs":"Vnitřní postup; Měření optické délky; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Měření optické délky","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Mnohovidové optické reflektometry"},{"_id":"a3efaebc178f51a0c17ac3c6","lab_id":"6af798980ecd48de0c7068a7","country":"PL","accr_number":"AP 210","accr_body":"PCA","test_object":"Źródła promieniowania optycznego\nReflektometry światłowodowe jednomodowe","test_object_en":"Optical radiation sources\nSingle-mode optical time-domain reflectometers","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 1310 nm:","range":"-50 dBm do 5 dBm","cmc":"5,28 %"},{"name":"długość fali 1550 nm:","range":"-50 dBm do 5 dBm","cmc":"5,30 %"},{"name":"długość fali 1625 nm:","range":"-50 dBm do 5 dBm","cmc":"5,28 %"}],"parameters_en":[{"name":"wavelength 1310 nm:","range":"-50 dBm to 5 dBm","cmc":"5,28 %"},{"name":"wavelength 1550 nm:","range":"-50 dBm to 5 dBm","cmc":"5,30 %"},{"name":"wavelength 1625 nm:","range":"-50 dBm to 5 dBm","cmc":"5,28 %"}],"technique":"Procedura wewnętrzna; Pomiar poziomu mocy optycznej; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Optical power level measurement; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Pomiar poziomu mocy optycznej","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Optical power level measurement","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm: -50 dBm do 5 dBm CMC 5,28 %\ndługość fali 1550 nm: -50 dBm do 5 dBm CMC 5,30 %\ndługość fali 1625 nm: -50 dBm do 5 dBm CMC 5,28 %\nProcedura wewnętrzna; Pomiar poziomu mocy optycznej; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-01, PW-04 w oparciu o PN-EN 61280-1-1:2013-10","norm_bases":["PW-01","PW-04","PN-EN 61280-1-1:2013-10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Źródła promieniowania optycznego\nReflektometry światłowodowe jednomodowe Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm: -50 dBm do 5 dBm CMC 5,28 %\ndługość fali 1550 nm: -50 dBm do 5 dBm CMC 5,30 %\ndługość fali 1625 nm: -50 dBm do 5 dBm CMC 5,28 %\nProcedura wewnętrzna; Pomiar poziomu mocy optycznej; W stałej lokalizacji (S) i poza nią (P) PW-01, PW-04 w oparciu o PN-EN 61280-1-1:2013-10 Zrodla promieniowania optycznego\nReflektometry swiatlowodowe jednomodowe Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 1310 nm: -50 dBm do 5 dBm CMC 5,28 %\ndlugosc fali 1550 nm: -50 dBm do 5 dBm CMC 5,30 %\ndlugosc fali 1625 nm: -50 dBm do 5 dBm CMC 5,28 %\nProcedura wewnetrzna; Pomiar poziomu mocy optycznej; W stalej lokalizacji (S) i poza nia (P) PW-01, PW-04 w oparciu o PN-EN 61280-1-1:2013-10","search_en":"Optical radiation sources Single-mode optical time-domain reflectometers Calibration — Optoelectronic quantities Internal procedure; Optical power level measurement; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Optical power level measurement At permanent location (S) and outside of it (P) wavelength 1310 nm: wavelength 1550 nm: wavelength 1625 nm: PW-01, PW-04 based on PN-EN 61280-1-1:2013-10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-01, PW-04 based on PN-EN 61280-1-1:2013-10","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 1310 nm:","range":"-50 dBm to 5 dBm","cmc":"5,28 %"},{"name":"Wellenlänge 1550 nm:","range":"-50 dBm to 5 dBm","cmc":"5,30 %"},{"name":"Wellenlänge 1625 nm:","range":"-50 dBm to 5 dBm","cmc":"5,28 %"}],"reference_de":"PW-01, PW-04 auf Grundlage von PN-EN 61280-1-1:2013-10","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Strahlungsquellen Singlemode-Lichtwellenleiter-Reflektometer (OTDR) Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Messung des optischen Leistungspegels; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Messung des optischen Leistungspegels Am festen Standort (S) und außerhalb (P) Wellenlänge 1310 nm: Wellenlänge 1550 nm: Wellenlänge 1625 nm: PW-01, PW-04 auf Grundlage von PN-EN 61280-1-1:2013-10","technique_de":"Interne Verfahrensanweisung; Messung des optischen Leistungspegels; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Messung des optischen Leistungspegels","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Strahlungsquellen\nSinglemode-Lichtwellenleiter-Reflektometer (OTDR)","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 1310 nm：","range":"-50 dBm to 5 dBm","cmc":"5,28 %"},{"name":"波长 1550 nm：","range":"-50 dBm to 5 dBm","cmc":"5,30 %"},{"name":"波长 1625 nm：","range":"-50 dBm to 5 dBm","cmc":"5,28 %"}],"reference_zh":"PW-01, PW-04 依据PN-EN 61280-1-1:2013-10","regulatory_area_zh":"光电量","search_zh":"光辐射源 单模光时域反射仪 校准 — 光电量 内部程序；光功率电平测量；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 光功率电平测量 在固定地点 (S) 及固定地点以外 (P) 波长 1310 nm： 波长 1550 nm： 波长 1625 nm： PW-01, PW-04 依据PN-EN 61280-1-1:2013-10","technique_zh":"内部程序；光功率电平测量；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","光功率电平测量","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光辐射源\n单模光时域反射仪","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 1310 nm:","range":"-50 dBm to 5 dBm","cmc":"5,28 %"},{"name":"vlnová délka 1550 nm:","range":"-50 dBm to 5 dBm","cmc":"5,30 %"},{"name":"vlnová délka 1625 nm:","range":"-50 dBm to 5 dBm","cmc":"5,28 %"}],"reference_cs":"PW-01, PW-04 na základě PN-EN 61280-1-1:2013-10","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Zdroje optického záření Jednovidové optické reflektometry Kalibrace — Optoelektronické veličiny Vnitřní postup; Měření úrovně optického výkonu; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Měření úrovně optického výkonu V trvalé lokalitě (S) i mimo ni (P) vlnová délka 1310 nm: vlnová délka 1550 nm: vlnová délka 1625 nm: PW-01, PW-04 na základě PN-EN 61280-1-1:2013-10","technique_cs":"Vnitřní postup; Měření úrovně optického výkonu; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Měření úrovně optického výkonu","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Zdroje optického záření\nJednovidové optické reflektometry"},{"_id":"605964c3cde5626e0f62fd01","lab_id":"6af798980ecd48de0c7068a7","country":"PL","accr_number":"AP 210","accr_body":"PCA","test_object":"Źródła promieniowania optycznego\nReflektometry światłowodowe jednomodowe","test_object_en":"Optical radiation sources\nSingle-mode optical time-domain reflectometers","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"","range":"1310 nm","cmc":"0,002 nm"},{"name":"","range":"1500 nm do 1640 nm","cmc":"0,002 nm"}],"parameters_en":[{"name":"","range":"1310 nm","cmc":"0,002 nm"},{"name":"","range":"1500 nm to 1640 nm","cmc":"0,002 nm"}],"technique":"Procedura wewnętrzna; Pomiar środkowej długości fali; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Central wavelength measurement; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Pomiar środkowej długości fali","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Central wavelength measurement","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\n1310 nm CMC 0,002 nm\n1500 nm do 1640 nm CMC 0,002 nm\nProcedura wewnętrzna; Pomiar środkowej długości fali; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-01, PW-04 w oparciu o PN-EN IEC 61280-1-3: 2022-04","norm_bases":["PW-01","PW-04","PN-EN IEC 61280-1-3: 2022-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Źródła promieniowania optycznego\nReflektometry światłowodowe jednomodowe Wzorcowanie — Wielkości optoelektroniczne\nZakres:\n1310 nm CMC 0,002 nm\n1500 nm do 1640 nm CMC 0,002 nm\nProcedura wewnętrzna; Pomiar środkowej długości fali; W stałej lokalizacji (S) i poza nią (P) PW-01, PW-04 w oparciu o PN-EN IEC 61280-1-3: 2022-04 Zrodla promieniowania optycznego\nReflektometry swiatlowodowe jednomodowe Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\n1310 nm CMC 0,002 nm\n1500 nm do 1640 nm CMC 0,002 nm\nProcedura wewnetrzna; Pomiar srodkowej dlugosci fali; W stalej lokalizacji (S) i poza nia (P) PW-01, PW-04 w oparciu o PN-EN IEC 61280-1-3: 2022-04","search_en":"Optical radiation sources Single-mode optical time-domain reflectometers Calibration — Optoelectronic quantities Internal procedure; Central wavelength measurement; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Central wavelength measurement At permanent location (S) and outside of it (P) PW-01, PW-04 based on PN-EN IEC 61280-1-3: 2022-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-01, PW-04 based on PN-EN IEC 61280-1-3: 2022-04","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"","range":"1310 nm","cmc":"0,002 nm"},{"name":"","range":"1500 nm to 1640 nm","cmc":"0,002 nm"}],"reference_de":"PW-01, PW-04 auf Grundlage von PN-EN IEC 61280-1-3: 2022-04","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Strahlungsquellen Singlemode-Lichtwellenleiter-Reflektometer (OTDR) Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Messung der Mittenwellenlänge; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Messung der Mittenwellenlänge Am festen Standort (S) und außerhalb (P) PW-01, PW-04 auf Grundlage von PN-EN IEC 61280-1-3: 2022-04","technique_de":"Interne Verfahrensanweisung; Messung der Mittenwellenlänge; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Messung der Mittenwellenlänge","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Strahlungsquellen\nSinglemode-Lichtwellenleiter-Reflektometer (OTDR)","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"","range":"1310 nm","cmc":"0,002 nm"},{"name":"","range":"1500 nm to 1640 nm","cmc":"0,002 nm"}],"reference_zh":"PW-01, PW-04 依据PN-EN IEC 61280-1-3: 2022-04","regulatory_area_zh":"光电量","search_zh":"光辐射源 单模光时域反射仪 校准 — 光电量 内部程序；中心波长测量；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 中心波长测量 在固定地点 (S) 及固定地点以外 (P) PW-01, PW-04 依据PN-EN IEC 61280-1-3: 2022-04","technique_zh":"内部程序；中心波长测量；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","中心波长测量","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光辐射源\n单模光时域反射仪","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"","range":"1310 nm","cmc":"0,002 nm"},{"name":"","range":"1500 nm to 1640 nm","cmc":"0,002 nm"}],"reference_cs":"PW-01, PW-04 na základě PN-EN IEC 61280-1-3: 2022-04","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Zdroje optického záření Jednovidové optické reflektometry Kalibrace — Optoelektronické veličiny Vnitřní postup; Měření střední vlnové délky; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Měření střední vlnové délky V trvalé lokalitě (S) i mimo ni (P) PW-01, PW-04 na základě PN-EN IEC 61280-1-3: 2022-04","technique_cs":"Vnitřní postup; Měření střední vlnové délky; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Měření střední vlnové délky","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Zdroje optického záření\nJednovidové optické reflektometry"},{"_id":"d9d107bbc577ab548a9a8f22","lab_id":"6af798980ecd48de0c7068a7","country":"PL","accr_number":"AP 210","accr_body":"PCA","test_object":"Mierniki mocy (poziomu mocy) promieniowania optycznego","test_object_en":"Optical power (power level) meters","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 1310 nm:","range":"-50 dBm do 5 dBm","cmc":"2,44 %"},{"name":"długość fali 1490 nm:","range":"-50 dBm do 5 dBm","cmc":"2,46 %"},{"name":"długość fali 1550 nm:","range":"-50 dBm do 5 dBm","cmc":"2,44 %"},{"name":"długość fali 1625 nm:","range":"-50 dBm do 5 dBm","cmc":"2,44 %"}],"parameters_en":[{"name":"wavelength 1310 nm:","range":"-50 dBm to 5 dBm","cmc":"2,44 %"},{"name":"wavelength 1490 nm:","range":"-50 dBm to 5 dBm","cmc":"2,46 %"},{"name":"wavelength 1550 nm:","range":"-50 dBm to 5 dBm","cmc":"2,44 %"},{"name":"wavelength 1625 nm:","range":"-50 dBm to 5 dBm","cmc":"2,44 %"}],"technique":"Procedura wewnętrzna; Pomiar poziomu mocy optycznej; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Optical power level measurement; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Pomiar poziomu mocy optycznej","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Optical power level measurement","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm: -50 dBm do 5 dBm CMC 2,44 %\ndługość fali 1490 nm: -50 dBm do 5 dBm CMC 2,46 %\ndługość fali 1550 nm: -50 dBm do 5 dBm CMC 2,44 %\ndługość fali 1625 nm: -50 dBm do 5 dBm CMC 2,44 %\nProcedura wewnętrzna; Pomiar poziomu mocy optycznej; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-03 w oparciu o PN-EN IEC 61315:2019-10","norm_bases":["PW-03","PN-EN IEC 61315:2019-10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy (poziomu mocy) promieniowania optycznego Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm: -50 dBm do 5 dBm CMC 2,44 %\ndługość fali 1490 nm: -50 dBm do 5 dBm CMC 2,46 %\ndługość fali 1550 nm: -50 dBm do 5 dBm CMC 2,44 %\ndługość fali 1625 nm: -50 dBm do 5 dBm CMC 2,44 %\nProcedura wewnętrzna; Pomiar poziomu mocy optycznej; W stałej lokalizacji (S) i poza nią (P) PW-03 w oparciu o PN-EN IEC 61315:2019-10 Mierniki mocy (poziomu mocy) promieniowania optycznego Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 1310 nm: -50 dBm do 5 dBm CMC 2,44 %\ndlugosc fali 1490 nm: -50 dBm do 5 dBm CMC 2,46 %\ndlugosc fali 1550 nm: -50 dBm do 5 dBm CMC 2,44 %\ndlugosc fali 1625 nm: -50 dBm do 5 dBm CMC 2,44 %\nProcedura wewnetrzna; Pomiar poziomu mocy optycznej; W stalej lokalizacji (S) i poza nia (P) PW-03 w oparciu o PN-EN IEC 61315:2019-10","search_en":"Optical power (power level) meters Calibration — Optoelectronic quantities Internal procedure; Optical power level measurement; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Optical power level measurement At permanent location (S) and outside of it (P) wavelength 1310 nm: wavelength 1490 nm: wavelength 1550 nm: wavelength 1625 nm: PW-03 based on PN-EN IEC 61315:2019-10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-03 based on PN-EN IEC 61315:2019-10","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 1310 nm:","range":"-50 dBm to 5 dBm","cmc":"2,44 %"},{"name":"Wellenlänge 1490 nm:","range":"-50 dBm to 5 dBm","cmc":"2,46 %"},{"name":"Wellenlänge 1550 nm:","range":"-50 dBm to 5 dBm","cmc":"2,44 %"},{"name":"Wellenlänge 1625 nm:","range":"-50 dBm to 5 dBm","cmc":"2,44 %"}],"reference_de":"PW-03 auf Grundlage von PN-EN IEC 61315:2019-10","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Leistungs(pegel)messgeräte Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Messung des optischen Leistungspegels; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Messung des optischen Leistungspegels Am festen Standort (S) und außerhalb (P) Wellenlänge 1310 nm: Wellenlänge 1490 nm: Wellenlänge 1550 nm: Wellenlänge 1625 nm: PW-03 auf Grundlage von PN-EN IEC 61315:2019-10","technique_de":"Interne Verfahrensanweisung; Messung des optischen Leistungspegels; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Messung des optischen Leistungspegels","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Leistungs(pegel)messgeräte","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 1310 nm：","range":"-50 dBm to 5 dBm","cmc":"2,44 %"},{"name":"波长 1490 nm：","range":"-50 dBm to 5 dBm","cmc":"2,46 %"},{"name":"波长 1550 nm：","range":"-50 dBm to 5 dBm","cmc":"2,44 %"},{"name":"波长 1625 nm：","range":"-50 dBm to 5 dBm","cmc":"2,44 %"}],"reference_zh":"PW-03 依据PN-EN IEC 61315:2019-10","regulatory_area_zh":"光电量","search_zh":"光功率（功率电平）计 校准 — 光电量 内部程序；光功率电平测量；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 光功率电平测量 在固定地点 (S) 及固定地点以外 (P) 波长 1310 nm： 波长 1490 nm： 波长 1550 nm： 波长 1625 nm： PW-03 依据PN-EN IEC 61315:2019-10","technique_zh":"内部程序；光功率电平测量；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","光功率电平测量","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光功率（功率电平）计","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 1310 nm:","range":"-50 dBm to 5 dBm","cmc":"2,44 %"},{"name":"vlnová délka 1490 nm:","range":"-50 dBm to 5 dBm","cmc":"2,46 %"},{"name":"vlnová délka 1550 nm:","range":"-50 dBm to 5 dBm","cmc":"2,44 %"},{"name":"vlnová délka 1625 nm:","range":"-50 dBm to 5 dBm","cmc":"2,44 %"}],"reference_cs":"PW-03 na základě PN-EN IEC 61315:2019-10","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Měřiče výkonu (úrovně výkonu) optického záření Kalibrace — Optoelektronické veličiny Vnitřní postup; Měření úrovně optického výkonu; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Měření úrovně optického výkonu V trvalé lokalitě (S) i mimo ni (P) vlnová délka 1310 nm: vlnová délka 1490 nm: vlnová délka 1550 nm: vlnová délka 1625 nm: PW-03 na základě PN-EN IEC 61315:2019-10","technique_cs":"Vnitřní postup; Měření úrovně optického výkonu; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Měření úrovně optického výkonu","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče výkonu (úrovně výkonu) optického záření"},{"_id":"13dbf2e03ed1a8bdc22d86f8","lab_id":"6af798980ecd48de0c7068a7","country":"PL","accr_number":"AP 210","accr_body":"PCA","test_object":"Mierniki mocy (poziomu mocy) promieniowania optycznego","test_object_en":"Optical power (power level) meters","methodology":"Wzorcowanie — Wielkości optoelektroniczne","methodology_en":"Calibration — Optoelectronic quantities","parameters":[{"name":"długość fali 1310 nm:","range":"-50 dBm do 5 dBm","cmc":"0,72 %"},{"name":"długość fali 1490 nm:","range":"-50 dBm do 5 dBm","cmc":"0,72 %"},{"name":"długość fali 1550 nm:","range":"-50 dBm do 5 dBm","cmc":"0,72 %"},{"name":"długość fali 1625 nm:","range":"-50 dBm do 5 dBm","cmc":"0,72 %"}],"parameters_en":[{"name":"wavelength 1310 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"wavelength 1490 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"wavelength 1550 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"wavelength 1625 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"}],"technique":"Procedura wewnętrzna; Pomiar nieliniowości mocy optycznej; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Optical power non-linearity measurement; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Pomiar nieliniowości mocy optycznej","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Optical power non-linearity measurement","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm: -50 dBm do 5 dBm CMC 0,72 %\ndługość fali 1490 nm: -50 dBm do 5 dBm CMC 0,72 %\ndługość fali 1550 nm: -50 dBm do 5 dBm CMC 0,72 %\ndługość fali 1625 nm: -50 dBm do 5 dBm CMC 0,72 %\nProcedura wewnętrzna; Pomiar nieliniowości mocy optycznej; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-03 oparta na normie PN-EN IEC 61315:2019-10","norm_bases":["PW-03","PN-EN IEC 61315:2019-10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości optoelektroniczne","regulatory_area_en":"Optoelectronic quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Mierniki mocy (poziomu mocy) promieniowania optycznego Wzorcowanie — Wielkości optoelektroniczne\nZakres:\ndługość fali 1310 nm: -50 dBm do 5 dBm CMC 0,72 %\ndługość fali 1490 nm: -50 dBm do 5 dBm CMC 0,72 %\ndługość fali 1550 nm: -50 dBm do 5 dBm CMC 0,72 %\ndługość fali 1625 nm: -50 dBm do 5 dBm CMC 0,72 %\nProcedura wewnętrzna; Pomiar nieliniowości mocy optycznej; W stałej lokalizacji (S) i poza nią (P) PW-03 oparta na normie PN-EN IEC 61315:2019-10 Mierniki mocy (poziomu mocy) promieniowania optycznego Wzorcowanie — Wielkosci optoelektroniczne\nZakres:\ndlugosc fali 1310 nm: -50 dBm do 5 dBm CMC 0,72 %\ndlugosc fali 1490 nm: -50 dBm do 5 dBm CMC 0,72 %\ndlugosc fali 1550 nm: -50 dBm do 5 dBm CMC 0,72 %\ndlugosc fali 1625 nm: -50 dBm do 5 dBm CMC 0,72 %\nProcedura wewnetrzna; Pomiar nieliniowosci mocy optycznej; W stalej lokalizacji (S) i poza nia (P) PW-03 oparta na normie PN-EN IEC 61315:2019-10","search_en":"Optical power (power level) meters Calibration — Optoelectronic quantities Internal procedure; Optical power non-linearity measurement; At permanent location (S) and outside of it (P) Optoelectronic quantities Internal procedure Optical power non-linearity measurement At permanent location (S) and outside of it (P) wavelength 1310 nm: wavelength 1490 nm: wavelength 1550 nm: wavelength 1625 nm: PW-03 based on standard PN-EN IEC 61315:2019-10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-03 based on standard PN-EN IEC 61315:2019-10","methodology_de":"Kalibrierung — Optoelektronische Größen","parameters_de":[{"name":"Wellenlänge 1310 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"Wellenlänge 1490 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"Wellenlänge 1550 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"Wellenlänge 1625 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"}],"reference_de":"PW-03 auf Grundlage der Norm PN-EN IEC 61315:2019-10","regulatory_area_de":"Optoelektronische Größen","search_de":"Optische Leistungs(pegel)messgeräte Kalibrierung — Optoelektronische Größen Interne Verfahrensanweisung; Messung der Nichtlinearität der optischen Leistung; Am festen Standort (S) und außerhalb (P) Optoelektronische Größen Internes Verfahren Messung der Nichtlinearität der optischen Leistung Am festen Standort (S) und außerhalb (P) Wellenlänge 1310 nm: Wellenlänge 1490 nm: Wellenlänge 1550 nm: Wellenlänge 1625 nm: PW-03 auf Grundlage der Norm PN-EN IEC 61315:2019-10","technique_de":"Interne Verfahrensanweisung; Messung der Nichtlinearität der optischen Leistung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Messung der Nichtlinearität der optischen Leistung","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Leistungs(pegel)messgeräte","methodology_zh":"校准 — 光电量","parameters_zh":[{"name":"波长 1310 nm：","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"波长 1490 nm：","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"波长 1550 nm：","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"波长 1625 nm：","range":"-50 dBm to 5 dBm","cmc":"0,72 %"}],"reference_zh":"PW-03 依据标准PN-EN IEC 61315:2019-10","regulatory_area_zh":"光电量","search_zh":"光功率（功率电平）计 校准 — 光电量 内部程序；光功率非线性测量；在固定地点 (S) 及固定地点以外 (P) 光电量 内部程序 光功率非线性测量 在固定地点 (S) 及固定地点以外 (P) 波长 1310 nm： 波长 1490 nm： 波长 1550 nm： 波长 1625 nm： PW-03 依据标准PN-EN IEC 61315:2019-10","technique_zh":"内部程序；光功率非线性测量；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","光功率非线性测量","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光功率（功率电平）计","methodology_cs":"Kalibrace — Optoelektronické veličiny","parameters_cs":[{"name":"vlnová délka 1310 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"vlnová délka 1490 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"vlnová délka 1550 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"},{"name":"vlnová délka 1625 nm:","range":"-50 dBm to 5 dBm","cmc":"0,72 %"}],"reference_cs":"PW-03 na základě normy PN-EN IEC 61315:2019-10","regulatory_area_cs":"Optoelektronické veličiny","search_cs":"Měřiče výkonu (úrovně výkonu) optického záření Kalibrace — Optoelektronické veličiny Vnitřní postup; Měření nelinearity optického výkonu; Ve stálé lokalitě (S) a mimo ni (P) Optoelektronické veličiny Vnitřní postup Měření nelinearity optického výkonu V trvalé lokalitě (S) i mimo ni (P) vlnová délka 1310 nm: vlnová délka 1490 nm: vlnová délka 1550 nm: vlnová délka 1625 nm: PW-03 na základě normy PN-EN IEC 61315:2019-10","technique_cs":"Vnitřní postup; Měření nelinearity optického výkonu; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Měření nelinearity optického výkonu","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče výkonu (úrovně výkonu) optického záření"}],"has_pdf":true}