🇵🇱 NDN - Zbigniew Daniluk PL
Metrology & calibration
NDN - Zbigniew Daniluk is a calibration laboratory accredited by PCA under number AP 209 (Warszawa, Poland). Its accreditation scope covers 39 calibration items in the following areas: Metrology & calibration. Calibrated items include: Scopemeters, Multimeters, Calibrators, Oscilloscopes. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S) and ou…, Internal procedure; Direct method; At permanent location (S), Internal procedure; Indirect method; At permanent location (S) and….
At a glance
- Accreditation number: PCA AP 209
- Calibration items in scope: 39
- Types of calibrated items: 42
- Calibration principles used: 3
- City: Warszawa, Poland
- Valid until: 10-07-2030
- Accreditation number
- AP 209
- Accreditation body
- PCA
- Address
- ul. Janowskiego 15, 02-784 Warszawa
- City
- Warszawa, Poland
- Valid until
- 10-07-2030
What this laboratory calibrates (42)
- Scopemeters — 11 calibration items
- Multimeters — 7 calibration items
- Calibrators — 6 calibration items
- Oscilloscopes — 6 calibration items
- Data acquisition cards — 5 calibration items
- Power supplies — 5 calibration items
- Clamp meters — 4 calibration items
- Electrical safety testers — 4 calibration items
- Power network parameter meters — 4 calibration items
- Power quality meters — 4 calibration items
- Electronic loads — 3 calibration items
- Generators — 3 calibration items
- Breakdown voltage meters — 2 calibration items
- Digital ammeters — 2 calibration items
- Digital voltmeters — 2 calibration items
- and 27 more
Calibration principles (3)
- Internal procedure; Direct method; At permanent location (S) and outside of it (P) — 33 calibration items
- Internal procedure; Direct method; At permanent location (S) — 4 calibration items
- Internal procedure; Indirect method; At permanent location (S) and outside of it (P) — 2 calibration items
Certificate information
- Issue date
- 12.06.2026
- Issue no.
- 7
- Certificate date
- 11.07.2022
- Accreditation cycle
- 12.06.2026 — 10.07.2030
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (39)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Multimeters Digital voltmeters Power quality meters Scopemeters Data acquisition cards |
Calibration — DC voltage 10 mV to 330 mV · CMC 23·10⁻⁶ · U + 1,2 µV 330 mV to 3,3 V · CMC 13·10⁻⁶·U + 2,1 µV 3,3 V to 33 V · CMC 14·10⁻⁶·U + 22 µV 33 V to 330 V · CMC 20·10⁻⁶·U + 0,2 mV 330 V to 1000 V · CMC 20·10⁻⁶·U + 2 mV DC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P16 based on Euramet cg-15 v. 3.0 02/2015 | |
| 2 | Calibrators Generators |
Calibration — DC voltage 10 mV to 100 mV · CMC 6·10⁻⁶·U + 0,2 µV 100 mV to 1 V · CMC 3·10⁻⁶·U + 0,2 µV 1 V to 10 V · CMC 3·10⁻⁶·U + 1,2 µV 10 V to 100 V · CMC 5·10⁻⁶·U + 0,03 mV 100 V to 1000 V · CMC 5·10⁻⁶·U + 0,7 mV DC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P17 | |
| 3 | Power supplies Electronic loads |
Calibration — DC voltage 10 mV to 100 mV · CMC 6·10⁻⁶·U + 0,2 µV 100 mV to 1 V · CMC 3·10⁻⁶·U + 0,2 µV 1 V to 10 V · CMC 3·10⁻⁶·U + 1,2 µV 10 V to 100 V · CMC 5·10⁻⁶·U + 0,03 mV 100 V to 1000 V · CMC 5·10⁻⁶·U + 0,7 mV DC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P17 | |
| 4 | Oscilloscopes Scopemeters |
Calibration — DC voltage 1 mV to 24,999 mV · CMC 3·10⁻³·U + 0,05 mV 25 mV to 109,99 mV · CMC 8·10⁻³·U + 0,03 mV 0,110 V to 2,1999 V · CMC 0,8 % 2,2 V to 10,999 V · CMC 0,8 % 11 V to 130 V · CMC 0,8 % 130 V to 1000 V · CMC 5·10⁻⁶·U + 0,7 mV DC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P20 | |
| 5 | Electrical safety testers Breakdown voltage meters Insulation resistance meters |
Calibration — DC voltage 10 V to 100 V · CMC 2·10⁻³ U + 0,05 V 100 V to 1100 V · CMC 2·10⁻³ U + 0,55 V 1100 V to 5000 V · CMC 3·10⁻³ U + 5,5 V 5 kV to 10 kV · CMC 3·10⁻³ U + 5 V DC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P22 | |
| 6 | Multimeters Digital ammeters Power quality meters Scopemeters Data acquisition cards Clamp meters |
Calibration — DC current 0,33 mA to 3,3 mA · CMC 0,12·10⁻³·I + 0,06 µA 3,3 mA to 33 mA · CMC 0,12·10⁻³·I + 0,2 µA 33mA to 330 mA · CMC 0,12·10⁻³·I + 0,2 µA 0,33 A to 1,1 A · CMC 0,24·10⁻³·I + 0,04 mA 1,1 A to 3 A · CMC 0,4·10⁻³·I + 0,04 mA 3 A to 11 A · CMC 0,58·10⁻³·I + 0,63 mA 11 A to 20 A · CMC 0,97·10⁻³·I + 1,8 mA DC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P16 based on Euramet cg-15 v. 3.0 02/2015 | |
| 7 | Clamp meters | Calibration — DC current 1 A to 1000 A · CMC 6,7·10⁻³·I + 0,5 A DC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P18 | |
| 8 | Calibrators | Calibration — DC current 0,1 mA to 10 mA · CMC 10·10⁻⁶·I + 0,05 µA 10 mA to 100 mA · CMC 0,11·10⁻³·I + 0,002 mA 0,1 A to 1 A · CMC 0,12·10⁻³·I + 0,11 mA 1 A to 2 A · CMC 0,13·10⁻³·I + 0,10 mA 2 A to 30 A · CMC 0,2·10⁻³·I + 0,5 mA DC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P17 | |
| 9 | Power supplies Electronic loads |
Calibration — DC current 0,1 mA to 10 mA · CMC 10·10⁻⁶·I + 0,05 µA 10 mA to 100 mA · CMC 0,11·10⁻³·I + 0,002 mA 0,1 A to 1 A · CMC 0,12·10⁻³·I + 0,11 mA 1 A to 2 A · CMC 0,13·10⁻³·I + 0,10 mA 2 A to 30 A · CMC 0,2·10⁻³·I + 0,5 mA 30 A to 400 A · CMC 0,2·10⁻³·I + 0,02 A 400 A to 1000 A · CMC 0,2·10⁻³·I + 0,02 A DC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P17 | |
| 10 | Multimeters Digital voltmeters Power quality meters Scopemeters Data acquisition cards |
Calibration — AC voltage 45 Hz to 10 kHz — 10 mV to 33 mV · CMC 0,13·10⁻³·U + 0,0074 mV 45 Hz to 10 kHz — 33 mV to 330 mV · CMC 0,16·10⁻³·U + 0,0096 mV 45 Hz to 10 kHz — 0,33 V to 3,3 V · CMC 0,18·10⁻³·U + 0,068 mV 45 Hz to 10 kHz — 3,3 V to 33 V · CMC 0,18·10⁻³·U + 0,68 mV 45 Hz to 10 kHz — 33 V to 330 V · CMC 0,22·10⁻³·U + 0,0022 V 45 Hz to 10 kHz — 330 V to 1000 V · CMC 0,2·10⁻³·U + 0,07 V AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P16 based on Euramet cg-15 v. 3.0 02/2015 | |
| 11 | Calibrators Generators |
Calibration — AC voltage 45 Hz to 2 kHz — 10 mV to 100 mV · CMC 40·10⁻⁶·U + 0,004 mV 45 Hz to 2 kHz — 0,1 V to 1 V · CMC 70·10⁻⁶·U + 0,0054 mV 45 Hz to 2 kHz — 1 V to 10 V · CMC 70·10⁻⁶·U + 0,054 mV 45 Hz to 2 kHz — 10 V to 100 V · CMC 80·10⁻⁶·U + 0,0006 V 45 Hz to 2 kHz — 100 V to 1000 V · CMC 0,1·10⁻³·U + 0,025 V 2 kHz to 10 kHz — 10 mV to 100 mV · CMC 90·10⁻⁶·U + 0,004 mV 2 kHz to 10 kHz — 0,1 V to 1 V · CMC 0,13·10⁻³·U + 0,007 mV 2 kHz to 10 kHz — 1 V to 10 V · CMC 0,13·10⁻³·U + 0,007 mV 2 kHz to 10 kHz — 10 V to 100 V · CMC 0,1·10⁻³·U + 0,54 mV 2 kHz to 10 kHz — 100 V to 1000 V · CMC 0,11·10⁻³·U + 0,025 V 10 kHz to 30 kHz — 10 mV to 100 mV · CMC 0.2·10⁻³·U + 0,001 mV 10 kHz to 30 kHz — 100 mV to 1 V · CMC 0.2·10⁻³·U + 0,01 mV 10 kHz to 30 kHz — 1V to 10 V · CMC 0.2·10⁻³·U + 0,1 mV 10 kHz to 30 kHz — 10 V to 100 V · CMC 0.2·10⁻³·U + 1 V 10 kHz to 30 kHz — 100 V to 1000 V · CMC 0.2·10⁻³·U + 2,5 V 30 kHz to 100 kHz — 10 mV to 100 mV · CMC 0.5·10⁻³·U + 0,005 mV 30 kHz to 100 kHz — 100 mV to 1 V · CMC 0.5·10⁻³·U + 0,05 mV 30 kHz to 100 kHz — 1V to 10 V · CMC 0.5·10⁻³·U + 0,5 mV 30 kHz to 100 kHz — 10 V to 100 V · CMC 0.5·10⁻³·U + 5 mV 30 kHz to 100 kHz — 100 V to 1000 V · CMC 0.5·10⁻³·U + 0,1 mV 100 kHz to 300 kHz — 10 mV to 100 mV · CMC 2·10⁻³·U + 0,03 mV 100 kHz to 300 kHz — 100 mV to 1 V · CMC 2·10⁻³·U + 0,3 mV 100 kHz to 300 kHz — 1V to 10 V · CMC 2·10⁻³·U + 3 mV 100 kHz to 300 kHz — 10 V to 100 V · CMC 3,5·10⁻³·U + 5 mV 300 kHz to 1 MHz — 10 mV to 100 mV · CMC 10·10⁻³·U + 0,01 mV 300 kHz to 1 MHz — 100 mV to 1 V · CMC 10·10⁻³·U + 0,01 mV 300 kHz to 1 MHz — 1V to 10 V · CMC 10·10⁻³·U + 0,1 mV 300 kHz to 1 MHz — 10 V to 100 V · CMC 10·10⁻³·U + 0,5 V 1 MHz to 2 MHz — 10 mV to 100 mV · CMC 15·10⁻³·U + 0,5 mV 1 MHz to 2 MHz — 100 mV to 1 V · CMC 15·10⁻³·U + 0,005 V 1 MHz to 2 MHz — 1V to 10 V · CMC 15·10⁻³·U + 0,05 V 2 MHz to 4 MHz — 10 mV to 100 mV · CMC 40·10⁻³·U + 1 mV 2 MHz to 4 MHz — 100 mV to 1 V · CMC 40·10⁻³·U + 0,01 V 2 MHz to 4 MHz — 1V to 10 V · CMC 40·10⁻³·U + 0,1 V 4 MHz to 8 MHz — 10 mV to 100 mV · CMC 80·10⁻³·U + 1 mV 4 MHz to 8 MHz — 100 mV to 1 V · CMC 80·10⁻³·U + 0,01 V 4 MHz to 8 MHz — 1V to 10 V · CMC 80·10⁻³·U + 0,1 V 8 MHz to 10 MHz — 10 mV to 100 mV · CMC 150·10⁻³·U + 1 mV 8 MHz to 10 MHz — 100 mV to 1 V · CMC 150·10⁻³·U + 0,01 V 8 MHz to 10 MHz — 1V to 10 V · CMC 150·10⁻³·U + 0,1 V AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P17 | |
| 12 | Power supplies Electronic loads |
Calibration — AC voltage 45 Hz to 2 kHz — 10 mV to 100 mV · CMC 40·10⁻⁶·U + 0,004 mV 45 Hz to 2 kHz — 0,1 V to 1 V · CMC 70·10⁻⁶·U + 0,0054 mV 45 Hz to 2 kHz — 1 V to 10 V · CMC 70·10⁻⁶·U + 0,054 mV 45 Hz to 2 kHz — 10 V to 100 V · CMC 80·10⁻⁶·U + 0,0006 V 45 Hz to 2 kHz — 100 V to 1000 V · CMC 0,1·10⁻³·U + 0,025 V AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P17 | |
| 13 | Oscilloscopes Scopemeters |
Calibration — AC voltage 50 kHz to 100 MHz — 5 mV to 5,5 V · CMC 40·10⁻³·U + 1 mV 100 MHz to 300 MHz — 5 mV to 5,5 V · CMC 45·10⁻³·U + 1 mV 300 MHz to 600 MHz — 5 mV to 5,5 V · CMC 70·10⁻³·U + 1 mV 600 MHz to 1,1 GHz — 5 mV to 3,5 V · CMC 80·10⁻³·U + 1 mV 1,1 GHz to 18 GHz — 5 mV to 3,5 V · CMC 10 % AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P20 | |
| 14 | Electrical safety testers Breakdown voltage meters |
Calibration — AC voltage 45 Hz to 2 kHz — 10 mV to 100 mV · CMC 40·10⁻⁶·U + 0,004 mV 45 Hz to 2 kHz — 0,1 V to 1 V · CMC 70·10⁻⁶·U + 0,0054 mV 45 Hz to 2 kHz — 1 V to 10 V · CMC 70·10⁻⁶·U + 0,054 mV 45 Hz to 2 kHz — 10 V to 100 V · CMC 80·10⁻⁶·U + 0,6 mV 45 Hz to 2 kHz — 100 V to 1100 V · CMC 0,1·10⁻³·U + 0,025 V 45 Hz to 2 kHz — 1100 V to 5000 V · CMC 3 10⁻³·U + 5,5 V 45 Hz to 2 kHz — 5 kV to 10 kV · CMC 3 10⁻³·U + 5 V AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P22 | |
| 15 | Multimeters Digital ammeters Power quality meters Scopemeters Data acquisition cards Clamp meters |
Calibration — AC current 45 Hz to 1 kHz — 0,33 mA to 3,3 mA · CMC 1,2·10⁻³·I + 0,1 µA 45 Hz to 1 kHz — 3,3 mA to 33 mA · CMC 4,6·10⁻³·I + 2,4 µA 45 Hz to 1 kHz — 33 mA to 330 mA · CMC 4,6·10⁻³·I + 2,4 µA 45 Hz to 1 kHz — 0,33 A to 1,1 A · CMC 5,8·10⁻³·I + 0,12 mA 45 Hz to 1 kHz — 1,1 A to 3 A · CMC 0,6·10⁻³·I + 0,3 mA 45 Hz to 1 kHz — 3 A to 11 A · CMC 1,2·10⁻³·I + 0,002 A 45 Hz to 1 kHz — 11 A to 20,5 A · CMC 1,7·10⁻³·I + 0,006 A AC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P16 based on Euramet cg-15 v. 3.0 02/2015 | |
| 16 | Electrical safety testers Leakage current meters |
Calibration — AC current 45 Hz to 1 kHz — 0,33 mA to 3,3 mA · CMC 1,2·10⁻³·I + 0,1 µA 45 Hz to 1 kHz — 3,3 mA to 33 mA · CMC 4,6·10⁻³·I + 2,4 µA 45 Hz to 1 kHz — 33 mA to 330 mA · CMC 4,6·10⁻³·I + 2,4 µA 45 Hz to 1 kHz — 0,33 A to 1,1 A · CMC 5,8·10⁻³·I + 0,12 mA 45 Hz to 1 kHz — 1,1 A to 3 A · CMC 0,6·10⁻³·I + 0,3 mA 45 Hz to 1 kHz — 3 A to 11 A · CMC 1,2·10⁻³·I + 0,002 A 45 Hz to 1 kHz — 11 A to 20 A · CMC 1,7·10⁻³·I + 0,006 A AC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P22 | |
| 17 | Clamp meters | Calibration — AC current 50 Hz — 1 A to 150 A · CMC 7·10⁻³·I + 0,5 A 50 Hz — 150 A to 1000 A · CMC 7·10⁻³·I + 0,9 A AC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P18 | |
| 18 | Calibrators | Calibration — AC current 45 Hz to 2 kHz — 1 mA to 20 mA · CMC 0,3·10⁻³·I + 0,6 µA 45 Hz to 2 kHz — 20 mA to 200 mA · CMC 0,3·10⁻³·I + 0,6 µA 45 Hz to 2 kHz — 0,2 A to 2 A · CMC 0,3·10⁻³·I + 0,12 mA 45 Hz to 2 kHz — 2 A to 20 A · CMC 0,9·10⁻³·I + 0,002 A 45 Hz to 2 kHz — 20 A to 30 A · CMC 2,5·10⁻³·I + 0,025 A AC current |
Internal procedure; Direct method; At permanent location (S) | Internal procedure P17 | |
| 19 | Power supplies | Calibration — AC current 45 Hz to 2 kHz — 1 mA to 20 mA · CMC 0,3·10⁻³·I + 0,6 µA 45 Hz to 2 kHz — 20 mA to 200 mA · CMC 0,3·10⁻³·I + 0,6 µA 45 Hz to 2 kHz — 0,2 A to 2 A · CMC 0,3·10⁻³·I + 0,12 mA 45 Hz to 2 kHz — 2 A to 20 A · CMC 0,9·10⁻³·I + 0,002 A 45 Hz to 2 kHz — 20 A to 30 A · CMC 2,5·10⁻³·I + 0,025 A AC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P17 | |
| 20 | Multimeters Digital ohmmeters Scopemeters Data acquisition cards Continuity testers Earth resistance meters Electrical safety testers |
Calibration — DC resistance 1 Ω to 10 Ω · CMC 12 mΩ 10 Ω to 100 kΩ · CMC 0,022 % 100 kΩ to 11 MΩ · CMC 0,061 % 11 MΩ to 33 MΩ · CMC 0.025 % 33 MΩ to 110 MΩ · CMC 0.05 % 110 MΩ to 330 MΩ · CMC 0,3 % 330 MΩ to 1100 MΩ · CMC 1,5 % DC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P16 based on Euramet cg-15 v. 3.0 02/2015 | |
| 21 | Calibrators Fixed resistors Variable resistors |
Calibration — DC resistance 1 Ω to 11 Ω · CMC 5,4 mΩ 11 Ω to 3,3 kΩ · CMC 0,023 % 3,3 kΩ to 3,3 MΩ · CMC 0,046 % 3,3 MΩ to 10 MΩ · CMC 0,47 % DC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P17 | |
| 22 | Oscilloscopes Scopemeters |
Calibration — DC resistance 40 Ω to 60 Ω · CMC 0,12 % 0,5 MΩ to 1,5 MΩ · CMC 0,12 % DC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P20 | |
| 23 | Insulation resistance meters Power network parameter meters |
Calibration — DC resistance Test voltage up to 65 V — 10 kΩ to 100 GΩ · CMC 0,2 % Test voltage up to 400 V — 40 kΩ to 100 GΩ · CMC 0,2 % Test voltage up to 800 V — 100 kΩ to 100 GΩ · CMC 0,2 % Test voltage up to 1100 V — 200 kΩ to 100 GΩ · CMC 0,2 % Test voltage up to 1575 V — 1 MΩ to 100 GΩ · CMC 0,3 % Test voltage up to 2500 V — 2 MΩ to 100 GΩ · CMC 0,3 % Test voltage up to 5500 V — 10 MΩ to 1000 MΩ · CMC 0,5 % Test voltage up to 5500 V — 1 GΩ to 10 GΩ · CMC 1,0 % Test voltage up to 5500 V — 10 GΩ to 100 GΩ · CMC 3,0 % DC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P22 | |
| 24 | Digital ohmmeters (two-wire method) Earth resistance meters (two-wire method) Electrical safety testers (two-wire method) |
Calibration — AC resistance 50 Hz — 20 mΩ to 50 mΩ · CMC 12 mΩ 50 Hz — 50 mΩ to 100 mΩ · CMC 12 mΩ 50 Hz — 100 mΩ to 350 mΩ · CMC 12 mΩ 50 Hz — 350 mΩ to 500 mΩ · CMC 14 mΩ 50 Hz — 500 mΩ to 960 mΩ · CMC 15 mΩ 50 Hz — 0,96 Ω to 1,7 Ω · CMC 20 mΩ 50 Hz — 1,7 Ω to 4,7 Ω · CMC 25 mΩ 50 Hz — 4,7 Ω to 9 Ω · CMC 37 mΩ 50 Hz — 9 Ω to 17 Ω · CMC 60 mΩ 50 Hz — 17 Ω to 47 Ω · CMC 100 mΩ 50 Hz — 47 Ω to 90 Ω · CMC 300 mΩ 50 Hz — 90 Ω to 170 Ω · CMC 500 mΩ 50 Hz — 170 Ω to 470 Ω · CMC 1Ω 50 Hz — 470 Ω to 900 Ω · CMC 5Ω 50 Hz — 900 Ω to 1700 Ω · CMC 10 Ω AC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P22 | |
| 25 | Digital ohmmeters (four-wire method) Earth resistance meters (four-wire method) Electrical safety testers (four-wire method) |
Calibration — AC resistance 50 Hz — 1 mΩ to 14 mΩ · CMC 0.2 mΩ 50 Hz — 14 mΩ to 39 mΩ · CMC 0.4 mΩ 50 Hz — 39 mΩ to 94 mΩ · CMC 0.7 mΩ 50 Hz — 94 mΩ to 340 mΩ · CMC 1.2 mΩ 50 Hz — 340 mΩ to 490 mΩ · CMC 2.0 mΩ 50 Hz — 490 mΩ to 960 mΩ · CMC 2.7 mΩ 50 Hz — 960 mΩ to 1,7 Ω · CMC 4.8 mΩ 50 Hz — 1,7 Ω to 4,7 Ω · CMC 8.5 mΩ 50 Hz — 4,7 Ω to 9 Ω · CMC 24 mΩ 50 Hz — 9 Ω to 17 Ω · CMC 85 mΩ 50 Hz — 17 Ω to 47 Ω · CMC 300 mΩ 50 Hz — 47 Ω to 90 Ω · CMC 500 mΩ 50 Hz — 90 Ω to 170 Ω · CMC 1Ω 50 Hz — 170 Ω to 470 Ω · CMC 2.5 Ω 50 Hz — 470 Ω to 900 Ω · CMC 5Ω 50 Hz — 900 Ω to 1700 Ω · CMC 10 Ω AC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P22 | |
| 26 | Multimeters | Calibration — Capacitance 1 kHz — 10 nF to 10 µF · CMC 1,9 % Capacitance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P16 based on Euramet cg-15 v. 3.0 02/2015 | |
| 27 | Oscilloscopes Scopemeters |
Calibration — Capacitance 5 pF to 50 pF · CMC 58·10⁻³·C + 0,58 pF Capacitance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P20 | |
| 28 | Power network parameter meters Digital phase meters |
Calibration — Phase angle -180° to 180°; 15 Hz to 70 Hz — 0,1 A to 10 A · CMC 0,012 ° -180° to 180°; 15 Hz to 70 Hz — 10 A to 30 A · CMC 0,058 ° Phase angle |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P19 | |
| 29 | Power meters | Calibration — DC power 0,03 W to 20,5 kW; 33 mV to 1020 V — 0,33 mA to 329,99 mA · CMC 0,027 % 0,03 W to 20,5 kW; 33 mV to 1020 V — 0,33 A to 2,9999 A · CMC 0,025 % 0,03 W to 20,5 kW; 33 mV to 1020 V — 3 A to 20,5 A · CMC 0,081 % DC power |
Internal procedure; Direct method; At permanent location (S) | Internal procedure P19 | |
| 30 | Digital single-phase active power meters Digital single-phase apparent power meters Digital single-phase reactive power meters Power network parameter meters |
Calibration — AC power 1,65 W to 20 kW; 1,65 VA to 20 kVA; 1,65 var to 20 kvar; 45 Hz to 65 Hz; 10 V to 1020 V; |cos (φ)| = 1; |sin (φ)| = 1 — 0,33 A to 1,0999 A · CMC 0,079 % 1,65 W to 20 kW; 1,65 VA to 20 kVA; 1,65 var to 20 kvar; 45 Hz to 65 Hz; 10 V to 1020 V; |cos (φ)| = 1; |sin (φ)| = 1 — 1,1 A to 2,1999 A · CMC 0,083 % 1,65 W to 20 kW; 1,65 VA to 20 kVA; 1,65 var to 20 kvar; 45 Hz to 65 Hz; 10 V to 1020 V; |cos (φ)| = 1; |sin (φ)| = 1 — 2,2 A to 4,499 A · CMC 0,078 % 1,65 W to 20 kW; 1,65 VA to 20 kVA; 1,65 var to 20 kvar; 45 Hz to 65 Hz; 10 V to 1020 V; |cos (φ)| = 1; |sin (φ)| = 1 — 4,5 A to 20,5 A · CMC 0,12 % 1,65 W to 20 kW; 1,65 VA to 20 kVA; 1,65 var to 20 kvar; 45 Hz to 65 Hz; 10 V to 1020 V; |cos (φ)| = 1 to 0,5; |sin (φ)| = 1 to 0,5 — 0,33 A to 1,0999 A · CMC 0,36 % 1,65 W to 20 kW; 1,65 VA to 20 kVA; 1,65 var to 20 kvar; 45 Hz to 65 Hz; 10 V to 1020 V; |cos (φ)| = 1 to 0,5; |sin (φ)| = 1 to 0,5 — 1,1 A to 2,1999 A · CMC 0,36 % 1,65 W to 20 kW; 1,65 VA to 20 kVA; 1,65 var to 20 kvar; 45 Hz to 65 Hz; 10 V to 1020 V; |cos (φ)| = 1 to 0,5; |sin (φ)| = 1 to 0,5 — 2,2 A to 4,499 A · CMC 0,36 % 1,65 W to 20 kW; 1,65 VA to 20 kVA; 1,65 var to 20 kvar; 45 Hz to 65 Hz; 10 V to 1020 V; |cos (φ)| = 1 to 0,5; |sin (φ)| = 1 to 0,5 — 4,5 A to 20,5 A · CMC 0,37 % 0,25 W to 600 kW; 0,25 VA to 600 kVA; 0,25 var to 600 kvar; 40 Hz to 70 Hz; 1 V to 600 V; |cos (φ)| = 1; |sin (φ)| = 1 — 0,5 A to 500 A · CMC 0,36 % 0,25 W to 600 kW; 0,25 VA to 600 kVA; 0,25 var to 600 kvar; 40 Hz to 70 Hz; 1 V to 600 V; |cos (φ)| = 1; |sin (φ)| = 1 — 500 A to 1000 A · CMC 0,37 % 0,25 W to 600 kW; 0,25 VA to 600 kVA; 0,25 var to 600 kvar; 40 Hz to 70 Hz; 1 V to 600 V; |cos (φ)| = 1 to 0,5; |sin (φ)| = 1 to 0,5 — 0,5 A to 500 A · CMC 0,36 % 0,25 W to 600 kW; 0,25 VA to 600 kVA; 0,25 var to 600 kvar; 40 Hz to 70 Hz; 1 V to 600 V; |cos (φ)| = 1 to 0,5; |sin (φ)| = 1 to 0,5 — 500 A to 1000 A · CMC 0,37 % AC power |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P19 | |
| 31 | Digital three-phase active power meters Digital three-phase apparent power meters Digital three-phase reactive power meters Power network parameter meters |
Calibration — AC power 0,75 W to 1,8 MW; 0,75 VA to 1,8 MVA; 0,75 var to 1,8 Mvar; 40 Hz to 70 Hz; 1 V to 600 V; |cos (φ)| = 1; |sin (φ)| = 1 — 0,5 A to 500 A · CMC 0,63 % 0,75 W to 1,8 MW; 0,75 VA to 1,8 MVA; 0,75 var to 1,8 Mvar; 40 Hz to 70 Hz; 1 V to 600 V; |cos (φ)| = 1; |sin (φ)| = 1 — 500 A to 1000 A · CMC 0,65 % 0,75 W to 1,8 MW; 0,75 VA to 1,8 MVA; 0,75 var to 1,8 Mvar; 40 Hz to 70 Hz; 1 V to 600 V; |cos (φ)| = 1 to 0,5; |sin (φ)| = 1 to 0,5 — 0,5 A to 500 A · CMC 0,63 % 0,75 W to 1,8 MW; 0,75 VA to 1,8 MVA; 0,75 var to 1,8 Mvar; 40 Hz to 70 Hz; 1 V to 600 V; |cos (φ)| = 1 to 0,5; |sin (φ)| = 1 to 0,5 — 500 A to 1000 A · CMC 0,65 % AC power |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P19 | |
| 32 | Temperature transmitters Temperature recorders Temperature indicators (meters) for use with resistance sensors |
Calibration — Electrical simulation of quantities -200 °C to 0 °C · CMC 0,08 °C 0°C to 100 °C · CMC 0,09 °C 100 °C to 300 °C · CMC 0,11 °C 300 °C to 400 °C · CMC 0,12 °C 400 °C to 630 °C · CMC 0,14 °C 630 °C to 800 °C · CMC 0,25 °C Electrical simulation of quantities |
Internal procedure; Indirect method; At permanent location (S) and outside of it (P) | Internal procedure P16 based on EURAMET cg-11 v.2.0 | |
| 33 | Temperature transmitters Temperature recorders Temperature indicators (meters) for use with thermocouples |
Calibration — Electrical simulation of quantities -200 °C to 1372 °C · CMC 0,72·10⁻³ · T + 0,64 °C Electrical simulation of quantities |
Internal procedure; Indirect method; At permanent location (S) and outside of it (P) | Internal procedure P16 based on EURAMET cg-11 v.2.0 | |
| 34 | Oscilloscopes Scopemeters |
Calibration — Time (time interval) 10 ns to 100 ms · CMC 2·10⁻⁶ · T + 2,9 ns Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | Internal procedure P20 | |
| 35 | Multimeters | Calibration — Frequency 3 Hz to 10 Hz · CMC 5·10⁻⁶ · F 10 Hz to 300 kHz · CMC 3·10⁻⁶ · F Frequency |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P16 based on Euramet cg-15 v. 3.0 02/2015 | |
| 36 | Calibrators | Calibration — Frequency 3 Hz to 300 kHz · CMC 0,08 % Frequency |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P17 | |
| 37 | Power supplies | Calibration — Frequency 3 Hz to 300 kHz · CMC 0,08 % Frequency |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P17 | |
| 38 | Oscilloscopes Scopemeters Digital frequency meters Spectrum analysers |
Calibration — Frequency 1 kHz to 20 GHz · CMC 2·10⁻⁶ · F Frequency |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure P20 | |
| 39 | Generators | Calibration — Frequency 1 Hz to 400 MHz · CMC 0,4 Hz 400 MHz to 8 GHz · CMC 3 Hz Frequency |
Internal procedure; Direct method; At permanent location (S) | Internal procedure P17 | |
Reference standards (8)
EURAMET cg-11 v.2.0
Euramet cg-15 v. 3.0 02/2015
P16
P17
P18
P19
P20
P22