🇵🇱 Okręgowy Urząd Miar w Białymstoku PL
Metrology & calibration
Okręgowy Urząd Miar w Białymstoku is a calibration laboratory accredited by PCA under number AP 185 (Białystok, Poland). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: Luxmeters 1), Non-automatic electronic weighing instruments, Sound calibrators, Sound level meters. Most frequently used calibration principles: At permanent location (S), Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P).
At a glance
- Accreditation number: PCA AP 185
- Calibration items in scope: 4
- Types of calibrated items: 4
- Calibration principles used: 3
- City: Białystok, Poland
- Valid until: 31-12-2026
- Accreditation number
- AP 185
- Accreditation body
- PCA
- Address
- ul. Kopernika 89, 15-396 Białystok
- City
- Białystok, Poland
- Division
- Calibration Laboratories Group
- Valid until
- 31-12-2026
What this laboratory calibrates (4)
- Luxmeters 1) — 1 calibration item
- Non-automatic electronic weighing instruments — 1 calibration item
- Sound calibrators — 1 calibration item
- Sound level meters — 1 calibration item
Calibration principles (3)
- At permanent location (S) — 2 calibration items
- Internal procedure; At permanent location (S) — 1 calibration item
- Internal procedure; At permanent location (S) and outside of it (P) — 1 calibration item
Certificate information
- Issue date
- 13.01.2025
- Issue no.
- 5
- Certificate date
- 28.11.2019
- Accreditation cycle
- 27.12.2022 — 31.12.2026
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (4)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Luxmeters 1) | Calibration — Illuminance 5 lx to 5000 lx · CMC 2,0 % Illuminance |
Internal procedure; At permanent location (S) | IW01.PR121.L3 | |
| 2 | Non-automatic electronic weighing instruments | Calibration — Mass (weighing instruments) up to 300 g · CMC 0,7 · d 300 g do 16 kg · CMC 0,7 · d 16 kg do 150 kg · CMC 0,7 · d 150 kg do 500 kg · CMC 0,7 · d Mass (weighing instruments) |
Internal procedure; At permanent location (S) and outside of it (P) | IW01.M121.L1 IW01.M122.L1 based on EURAMET cg-18 v. 4.0 | |
| 3 | Sound level meters | Calibration — Sound pressure (airborne sound) − response of the sound level meter to the signal from a sound calibrator — relative to 20 μPa; 94 dB to 124 dB · CMC 0,3 dB − response of the sound level meter to electrical test signals — relative to 20 μPa, frequency range 20 Hz to 20 kHz; 0 dB to 135 dB · CMC 0,2 dB - free-field frequency response of the sound level meter — frequency: 31,5 Hz to 500 Hz · CMC 0,4 dB - free-field frequency response of the sound level meter — frequency: 1 kHz · CMC 0,3 dB - free-field frequency response of the sound level meter — frequency: 2 kHz · CMC 0,4 dB - free-field frequency response of the sound level meter — frequency: 4 kHz to 8 kHz · CMC 0,5 dB - free-field frequency response of the sound level meter — frequency: 16 kHz · CMC 0,6 dB Sound pressure (airborne sound) |
At permanent location (S) | PN-EN 61672-3:2007 | |
| 4 | Sound calibrators | Calibration — Sound pressure (airborne sound) − sound pressure level — relative to 20 μPa, nominal frequency 1 kHz; 90 dB to 130 dB · CMC 0,10 dB Sound pressure (airborne sound) |
At permanent location (S) | PN-EN 60942:2005 | |
Reference standards (6)
EURAMET cg-18 v. 4.0
IW01.M121.L1
IW01.M122.L1
IW01.PR121.L3
PN-EN 60942:2005
PN-EN 61672-3:2007