🇵🇱 Operator Gazociągów Przesyłowych GAZ-SYSTEM S.A. PL

PCA AP 183 • Warszawa, Poland • 3 calibration items

Metrology & calibration

Operator Gazociągów Przesyłowych GAZ-SYSTEM S.A. is a calibration laboratory accredited by PCA under number AP 183 (Warszawa, Poland). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Hygrometers, Turbine gas meters, Ultrasonic gas meters. Most frequently used calibration principles: Internal procedure; Pressure calibration 8 bar to 54 bar; At perman…, Internal procedure; Outside of permanent location (P).

At a glance

  • Accreditation number: PCA AP 183
  • Calibration items in scope: 3
  • Types of calibrated items: 3
  • Calibration principles used: 2
  • City: Warszawa, Poland
  • Valid until: 11-12-2030
Accreditation number
AP 183
Accreditation body
PCA
Address
ul. Mszczonowska 4, 02-337 Warszawa
City
Warszawa, Poland
Valid until
11-12-2030

What this laboratory calibrates (3)

Calibration principles (2)

Laboratory locations

Certificate information

Issue date
12.11.2026
Issue no.
8
Certificate date
06.11.2019
Accreditation cycle
12.11.2026 — 11.12.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (3)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand. In other cases, CMC is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Turbine gas meters Calibration — Volumetric flow (flowrate – gases)
8 m³/h to 1600 m³/h · CMC 0,28 % 1600 m³/h to 4000 m³/h · CMC 0,22 %
Volumetric flow (flowrate – gases)
Internal procedure; Pressure calibration 8 bar to 54 bar; At permanent location (S) JB-PW-01
2 Ultrasonic gas meters Calibration — Volumetric flow (flowrate – gases)
- volume flow — 8 m³/h to 1600 m³/h · CMC 0,29 % - volume flow — 1600 m³/h to 6000 m³/h · CMC 0,22 %
Volumetric flow (flowrate – gases)
Internal procedure; Pressure calibration 8 bar to 54 bar; At permanent location (S) JB-PW-04
3 Hygrometers Calibration — Dew point temperature
- 30 °C to 5 °C · CMC 1,3 °C
Dew point temperature
Internal procedure; Outside of permanent location (P) JA-PW-PgW-01

Reference standards (3)

JA-PW-PgW-01
JB-PW-01
JB-PW-04

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20183