{"lab":{"_id":"6af574810ecd48de0c70625c","country":"PL","accr_number":"AP 183","imported_at":"2026-11-12T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Mszczonowska 4, 02-337 Warszawa","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"06.11.2019","city":"Warszawa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Wartość wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand. In other cases, CMC is expressed in measurand units.","cycle_from":"12.11.2026","cycle_to":"11.12.2030","email_source":"PCA","en_official":true,"fields_of_testing":[{"codes":"11.01","pl":"strumień objętości (przepływ-gazy)","en":"volumetric flow (flowrate – gases)","de":"Volumenstrom (Durchfluss-Gase)","zh":"体积流量（气体流量）","cs":"objemový průtok (průtok-plyny)"},{"codes":"14.01","pl":"temperatura punktu rosy","en":"dew point temperature","de":"Taupunkttemperatur","zh":"露点温度","cs":"teplota rosného bodu"}],"has_en":true,"has_zh":true,"issue":{"no":"8","date":"12.11.2026"},"issue_date":"12.11.2026","issue_number":"8","lab_division":null,"lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[20.948821,52.213382]},"map_coord":[52.213382,20.948821],"map_geo":"nominatim-street","methods_count":3,"name":"Operator Gazociągów Przesyłowych GAZ-SYSTEM S.A.","parse_date":"2026-11-14T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-14T12:00:00.000Z","pdf_files":["AP_183.pdf"],"scope_notes":[{"pl":"Tabela Laboratorium Pomiarów Jakości Gazu: niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej.","en":"Gas Quality Measurement Laboratory table: the uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in units of the measurand."}],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: strumień objętości (przepływ-gazy), temperatura punktu rosy. W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"operator gazociągów przesyłowych gaz-system s.a. ul. mszczonowska 4, 02-337 warszawa laboratorium wzorcujące. wielkości mierzone: strumień objętości (przepływ-gazy), temperatura punktu rosy. w stałej lokalizacji (s) i/lub poza nią (p). ap 183 ap183 laboratorium wzorcujące wzorcowanie kalibracja volumetric flow (flowrate – gases) dew point temperature operator gazociagow przesylowych gaz-system s.a. ul. mszczonowska 4, 02-337 warszawa laboratorium wzorcujace. wielkosci mierzone: strumien objetosci (przeplyw-gazy), temperatura punktu rosy. w stalej lokalizacji (s) i/lub poza nia (p). ap 183 ap183 laboratorium wzorcujace wzorcowanie kalibracja volumetric flow (flowrate – gases) dew point temperature","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20183,podmiot.html","source_pdf_sha256":"2fcbf48b8835dbe6453d97d4f455056779d184b67c3a16bf2f1e64047b7f856f","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/14/1d582b939b714c8800c3b18b48048fcc/AP%20183.pdf","status":"active","updated_at":"2026-11-14T12:00:00.000Z","valid_from":"12-12-2018","valid_until":"11-12-2030","website":"www.gaz-system.pl/pl/dla-klientow/uslugi-laboratoriow.html","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 %. Ein in Prozent angegebener Wert ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度。以百分比表示的数值为相对测量不确定度，指占被测量值的百分比。","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 %. Hodnota vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"pelny_cs":false,"lab_locations":[{"code":null,"name":"Operator Gazociągów Przesyłowych GAZ-SYSTEM S.A.","street":"ul. Mszczonowska 4","postal_code":"02-337","city":"Warszawa","is_hq":true,"address":"ul. Mszczonowska 4, 02-337 Warszawa","site":"02-337|mszczonowska4"},{"code":null,"name":"Laboratorium Wzorcowania Gazomierzy / Gas Meter Calibration Laboratory","street":"Klepaczew 46","postal_code":"08-221","city":"Sarnaki","is_hq":false,"address":"Klepaczew 46, 08-221 Sarnaki","site":"08-221|klepaczew46"},{"code":null,"name":"Laboratorium Pomiarów Jakości Gazu / Gas Quality Measurement Laboratory","street":"","postal_code":"33-152","city":"Pogórska Wola","is_hq":false,"address":"33-152 Pogórska Wola","site":"33-152|"}],"scope_format":"PCA::pracownie+siatka5"},"methods":[{"_id":"401fce8f23fce28c7e9d2c76","lab_id":"6af574810ecd48de0c70625c","country":"PL","accr_number":"AP 183","accr_body":"PCA","test_object":"Gazomierze turbinowe","test_object_en":"Turbine gas meters","methodology":"Wzorcowanie — Strumień objętości (przepływ-gazy)","methodology_en":"Calibration — Volumetric flow (flowrate – gases)","parameters":[{"name":"","range":"8 m³/h do 1600 m³/h","cmc":"0,28 %"},{"name":"","range":"1600 m³/h do 4000 m³/h","cmc":"0,22 %"}],"parameters_en":[{"name":"","range":"8 m³/h to 1600 m³/h","cmc":"0,28 %"},{"name":"","range":"1600 m³/h to 4000 m³/h","cmc":"0,22 %"}],"technique":"Procedura wewnętrzna; Wzorcowanie w zakresie ciśnienia 8 bar do 54 bar; W stałej lokalizacji (S)","technique_en":"Internal procedure; Pressure calibration 8 bar to 54 bar; At permanent location (S)","techniques":["Procedura wewnętrzna","Wzorcowanie w zakresie ciśnienia 8 bar do 54 bar","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Pressure calibration 8 bar to 54 bar","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Strumień objętości (przepływ-gazy)\nZakres:\n8 m³/h do 1600 m³/h CMC 0,28 %\n1600 m³/h do 4000 m³/h CMC 0,22 %\nProcedura wewnętrzna; Wzorcowanie w zakresie ciśnienia 8 bar do 54 bar; W stałej lokalizacji (S)","reference":"JB-PW-01","norm_bases":["JB-PW-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Strumień objętości (przepływ-gazy)","regulatory_area_en":"Volumetric flow (flowrate – gases)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Wzorcowania Gazomierzy, Klepaczew 46, 08-221 Sarnaki","note_en":"Gas Meter Calibration Laboratory, Klepaczew 46, 08-221 Sarnaki","search_text":"Gazomierze turbinowe Wzorcowanie — Strumień objętości (przepływ-gazy)\nZakres:\n8 m³/h do 1600 m³/h CMC 0,28 %\n1600 m³/h do 4000 m³/h CMC 0,22 %\nProcedura wewnętrzna; Wzorcowanie w zakresie ciśnienia 8 bar do 54 bar; W stałej lokalizacji (S) JB-PW-01 Gazomierze turbinowe Wzorcowanie — Strumien objetosci (przeplyw-gazy)\nZakres:\n8 m³/h do 1600 m³/h CMC 0,28 %\n1600 m³/h do 4000 m³/h CMC 0,22 %\nProcedura wewnetrzna; Wzorcowanie w zakresie cisnienia 8 bar do 54 bar; W stalej lokalizacji (S) JB-PW-01","search_en":"Turbine gas meters Calibration — Volumetric flow (flowrate – gases) Internal procedure; Pressure calibration 8 bar to 54 bar; At permanent location (S) Volumetric flow (flowrate – gases) Internal procedure Pressure calibration 8 bar to 54 bar At permanent location (S) JB-PW-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Volumenstrom (Durchfluss-Gase)","parameters_de":[{"name":"","range":"8 m³/h to 1600 m³/h","cmc":"0,28 %"},{"name":"","range":"1600 m³/h to 4000 m³/h","cmc":"0,22 %"}],"regulatory_area_de":"Volumenstrom (Durchfluss-Gase)","search_de":"Turbinenradgaszähler Kalibrierung — Volumenstrom (Durchfluss-Gase) Interne Verfahrensanweisung; Kalibrierung im Druckbereich 8 bar bis 54 bar; Am festen Standort (S) Volumenstrom (Durchfluss-Gase) Internes Verfahren Kalibrierung im Druckbereich 8 bar bis 54 bar Am festen Standort (S) JB-PW-01","technique_de":"Interne Verfahrensanweisung; Kalibrierung im Druckbereich 8 bar bis 54 bar; Am festen Standort (S)","techniques_de":["Internes Verfahren","Kalibrierung im Druckbereich 8 bar bis 54 bar","Am festen Standort (S)"],"test_object_de":"Turbinenradgaszähler","methodology_zh":"校准 — 体积流量（气体流量）","parameters_zh":[{"name":"","range":"8 m³/h to 1600 m³/h","cmc":"0,28 %"},{"name":"","range":"1600 m³/h to 4000 m³/h","cmc":"0,22 %"}],"regulatory_area_zh":"体积流量（气体流量）","search_zh":"涡轮气体流量计 校准 — 体积流量（气体流量） 内部程序；在 8 bar 至 54 bar 压力范围内校准；在固定地点 (S) 体积流量（气体流量） 内部程序 在 8 bar 至 54 bar 压力范围内校准 在固定地点 (S) JB-PW-01","technique_zh":"内部程序；在 8 bar 至 54 bar 压力范围内校准；在固定地点 (S)","techniques_zh":["内部程序","在 8 bar 至 54 bar 压力范围内校准","在固定地点 (S)"],"test_object_zh":"涡轮气体流量计","methodology_cs":"Kalibrace — Objemový průtok (průtok-plyny)","parameters_cs":[{"name":"","range":"8 m³/h to 1600 m³/h","cmc":"0,28 %"},{"name":"","range":"1600 m³/h to 4000 m³/h","cmc":"0,22 %"}],"regulatory_area_cs":"Objemový průtok (průtok-plyny)","search_cs":"Turbínové plynoměry Kalibrace — Objemový průtok (průtok-plyny) Vnitřní postup; Kalibrace v rozsahu tlaku 8 bar až 54 bar; Ve stálé lokalitě (S) Objemový průtok (průtok-plyny) Vnitřní postup Kalibrace v rozsahu tlaku 8 bar až 54 bar Ve stálé lokalitě (S) JB-PW-01","technique_cs":"Vnitřní postup; Kalibrace v rozsahu tlaku 8 bar až 54 bar; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Kalibrace v rozsahu tlaku 8 bar až 54 bar","Ve stálé lokalitě (S)"],"test_object_cs":"Turbínové plynoměry"},{"_id":"beb43426b18e0a0f53ac96a5","lab_id":"6af574810ecd48de0c70625c","country":"PL","accr_number":"AP 183","accr_body":"PCA","test_object":"Gazomierze ultradźwiękowe","test_object_en":"Ultrasonic gas meters","methodology":"Wzorcowanie — Strumień objętości (przepływ-gazy)","methodology_en":"Calibration — Volumetric flow (flowrate – gases)","parameters":[{"name":"- strumień objętości","range":"8 m³/h do 1600 m³/h","cmc":"0,29 %"},{"name":"- strumień objętości","range":"1600 m³/h do 6000 m³/h","cmc":"0,22 %"}],"parameters_en":[{"name":"- volume flow","range":"8 m³/h to 1600 m³/h","cmc":"0,29 %"},{"name":"- volume flow","range":"1600 m³/h to 6000 m³/h","cmc":"0,22 %"}],"technique":"Procedura wewnętrzna; Wzorcowanie w zakresie ciśnienia 8 bar do 54 bar; W stałej lokalizacji (S)","technique_en":"Internal procedure; Pressure calibration 8 bar to 54 bar; At permanent location (S)","techniques":["Procedura wewnętrzna","Wzorcowanie w zakresie ciśnienia 8 bar do 54 bar","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Pressure calibration 8 bar to 54 bar","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Strumień objętości (przepływ-gazy)\nZakres:\n- strumień objętości 8 m³/h do 1600 m³/h CMC 0,29 %\n- strumień objętości 1600 m³/h do 6000 m³/h CMC 0,22 %\nProcedura wewnętrzna; Wzorcowanie w zakresie ciśnienia 8 bar do 54 bar; W stałej lokalizacji (S)","reference":"JB-PW-04","norm_bases":["JB-PW-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Strumień objętości (przepływ-gazy)","regulatory_area_en":"Volumetric flow (flowrate – gases)","outside_premises":false,"location_of_activity":"S","note":"Laboratorium Wzorcowania Gazomierzy, Klepaczew 46, 08-221 Sarnaki","note_en":"Gas Meter Calibration Laboratory, Klepaczew 46, 08-221 Sarnaki","search_text":"Gazomierze ultradźwiękowe Wzorcowanie — Strumień objętości (przepływ-gazy)\nZakres:\n- strumień objętości 8 m³/h do 1600 m³/h CMC 0,29 %\n- strumień objętości 1600 m³/h do 6000 m³/h CMC 0,22 %\nProcedura wewnętrzna; Wzorcowanie w zakresie ciśnienia 8 bar do 54 bar; W stałej lokalizacji (S) JB-PW-04 Gazomierze ultradzwiekowe Wzorcowanie — Strumien objetosci (przeplyw-gazy)\nZakres:\n- strumien objetosci 8 m³/h do 1600 m³/h CMC 0,29 %\n- strumien objetosci 1600 m³/h do 6000 m³/h CMC 0,22 %\nProcedura wewnetrzna; Wzorcowanie w zakresie cisnienia 8 bar do 54 bar; W stalej lokalizacji (S) JB-PW-04","search_en":"Ultrasonic gas meters Calibration — Volumetric flow (flowrate – gases) Internal procedure; Pressure calibration 8 bar to 54 bar; At permanent location (S) Volumetric flow (flowrate – gases) Internal procedure Pressure calibration 8 bar to 54 bar At permanent location (S) - volume flow - volume flow JB-PW-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Volumenstrom (Durchfluss-Gase)","parameters_de":[{"name":"- Volumenstrom","range":"8 m³/h to 1600 m³/h","cmc":"0,29 %"},{"name":"- Volumenstrom","range":"1600 m³/h to 6000 m³/h","cmc":"0,22 %"}],"regulatory_area_de":"Volumenstrom (Durchfluss-Gase)","search_de":"Ultraschall-Gaszähler Kalibrierung — Volumenstrom (Durchfluss-Gase) Interne Verfahrensanweisung; Kalibrierung im Druckbereich 8 bar bis 54 bar; Am festen Standort (S) Volumenstrom (Durchfluss-Gase) Internes Verfahren Kalibrierung im Druckbereich 8 bar bis 54 bar Am festen Standort (S) - Volumenstrom - Volumenstrom JB-PW-04","technique_de":"Interne Verfahrensanweisung; Kalibrierung im Druckbereich 8 bar bis 54 bar; Am festen Standort (S)","techniques_de":["Internes Verfahren","Kalibrierung im Druckbereich 8 bar bis 54 bar","Am festen Standort (S)"],"test_object_de":"Ultraschall-Gaszähler","methodology_zh":"校准 — 体积流量（气体流量）","parameters_zh":[{"name":"- 体积流量","range":"8 m³/h to 1600 m³/h","cmc":"0,29 %"},{"name":"- 体积流量","range":"1600 m³/h to 6000 m³/h","cmc":"0,22 %"}],"regulatory_area_zh":"体积流量（气体流量）","search_zh":"超声波燃气表 校准 — 体积流量（气体流量） 内部程序；在 8 bar 至 54 bar 压力范围内校准；在固定地点 (S) 体积流量（气体流量） 内部程序 在 8 bar 至 54 bar 压力范围内校准 在固定地点 (S) - 体积流量 - 体积流量 JB-PW-04","technique_zh":"内部程序；在 8 bar 至 54 bar 压力范围内校准；在固定地点 (S)","techniques_zh":["内部程序","在 8 bar 至 54 bar 压力范围内校准","在固定地点 (S)"],"test_object_zh":"超声波燃气表","methodology_cs":"Kalibrace — Objemový průtok (průtok-plyny)","parameters_cs":[{"name":"- objemový průtok","range":"8 m³/h to 1600 m³/h","cmc":"0,29 %"},{"name":"- objemový průtok","range":"1600 m³/h to 6000 m³/h","cmc":"0,22 %"}],"regulatory_area_cs":"Objemový průtok (průtok-plyny)","search_cs":"Ultrazvukové plynoměry Kalibrace — Objemový průtok (průtok-plyny) Vnitřní postup; Kalibrace v rozsahu tlaku 8 bar až 54 bar; Ve stálé lokalitě (S) Objemový průtok (průtok-plyny) Vnitřní postup Kalibrace v rozsahu tlaku 8 bar až 54 bar Ve stálé lokalitě (S) - objemový průtok - objemový průtok JB-PW-04","technique_cs":"Vnitřní postup; Kalibrace v rozsahu tlaku 8 bar až 54 bar; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Kalibrace v rozsahu tlaku 8 bar až 54 bar","Ve stálé lokalitě (S)"],"test_object_cs":"Ultrazvukové plynoměry"},{"_id":"8547a719aed98dc3e6fd6aab","lab_id":"6af574810ecd48de0c70625c","country":"PL","accr_number":"AP 183","accr_body":"PCA","test_object":"Higrometry","test_object_en":"Hygrometers","methodology":"Wzorcowanie — Temperatura punktu rosy","methodology_en":"Calibration — Dew point temperature","parameters":[{"name":"","range":"- 30 °C do 5 °C","cmc":"1,3 °C"}],"parameters_en":[{"name":"","range":"- 30 °C to 5 °C","cmc":"1,3 °C"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura punktu rosy\n- 30 °C do 5 °C CMC 1,3 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"JA-PW-PgW-01","norm_bases":["JA-PW-PgW-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura punktu rosy","regulatory_area_en":"Dew point temperature","outside_premises":true,"location_of_activity":"P","note":"Laboratorium Pomiarów Jakości Gazu, 33-152 Pogórska Wola 450","note_en":"Gas Quality Measurement Laboratory, 33-152 Pogórska Wola 450","search_text":"Higrometry Wzorcowanie — Temperatura punktu rosy\n- 30 °C do 5 °C CMC 1,3 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P) JA-PW-PgW-01 Higrometry Wzorcowanie — Temperatura punktu rosy\n- 30 °C do 5 °C CMC 1,3 °C\nProcedura wewnetrzna; Poza stala lokalizacja (P) JA-PW-PgW-01","search_en":"Hygrometers Calibration — Dew point temperature Internal procedure; Outside of permanent location (P) Dew point temperature Internal procedure Outside of permanent location (P) JA-PW-PgW-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Taupunkttemperatur","parameters_de":[{"name":"","range":"- 30 °C to 5 °C","cmc":"1,3 °C"}],"regulatory_area_de":"Taupunkttemperatur","search_de":"Hygrometer Kalibrierung — Taupunkttemperatur Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Taupunkttemperatur Internes Verfahren Außerhalb des festen Standorts (P) JA-PW-PgW-01","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Hygrometer","methodology_zh":"校准 — 露点温度","parameters_zh":[{"name":"","range":"- 30 °C to 5 °C","cmc":"1,3 °C"}],"regulatory_area_zh":"露点温度","search_zh":"湿度计 校准 — 露点温度 内部程序；固定地点以外 (P) 露点温度 内部程序 固定地点以外 (P) JA-PW-PgW-01","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"湿度计","methodology_cs":"Kalibrace — Teplota rosného bodu","parameters_cs":[{"name":"","range":"- 30 °C to 5 °C","cmc":"1,3 °C"}],"regulatory_area_cs":"Teplota rosného bodu","search_cs":"Vlhkoměry Kalibrace — Teplota rosného bodu Vnitřní postup; Mimo stálé pracoviště (P) Teplota rosného bodu Vnitřní postup Mimo stálou lokalitu (P) JA-PW-PgW-01","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Vlhkoměry"}],"has_pdf":true}