🇵🇱 Testo Industrial Services sp. z o.o. PL
Metrology & calibration
Testo Industrial Services sp. z o.o. is a calibration laboratory accredited by PCA under number AP 176 (Warszawa, Poland). Its accreditation scope covers 37 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Multimeters, Analogue voltmeters, Digital voltmeters. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S) and ou…, Direct and indirect method; At permanent location (S) and outside o…, Direct method; At permanent location (S) and outside of it (P).
At a glance
- Accreditation number: PCA AP 176
- Calibration items in scope: 37
- Types of calibrated items: 33
- Calibration principles used: 10
- City: Warszawa, Poland
- Valid until: 06-12-2029
- Accreditation number
- AP 176
- Accreditation body
- PCA
- Address
- Aleja Krakowska 2A, 02-284 Warszawa
- City
- Warszawa, Poland
- Valid until
- 06-12-2029
What this laboratory calibrates (33)
- Calibrators — 6 calibration items
- Multimeters — 6 calibration items
- Analogue voltmeters — 3 calibration items
- Digital voltmeters — 3 calibration items
- Analogue ammeters — 2 calibration items
- Clamp meters — 2 calibration items
- Climatic chambers — 2 calibration items
- Conductivity meters — 2 calibration items
- Digital ammeters — 2 calibration items
- pH meters — 2 calibration items
- Power supplies — 2 calibration items
- Analogue ohmmeters — 1 calibration item
- Anemometers — 1 calibration item
- Barometers — 1 calibration item
- Digital ohmmeters — 1 calibration item
- and 18 more
Calibration principles (10)
- Internal procedure; Direct method; At permanent location (S) and outside of it (P) — 7 calibration items
- Direct and indirect method; At permanent location (S) and outside of it (P) — 6 calibration items
- Direct method; At permanent location (S) and outside of it (P) — 5 calibration items
- At permanent location (S) — 4 calibration items
- At permanent location (S) and outside of it (P) — 3 calibration items
- Internal procedure; At permanent location (S) — 3 calibration items
- Internal procedure; At permanent location (S) and outside of it (P) — 3 calibration items
- Indirect electrical method; At permanent location (S) and outside of it (P) — 2 calibration items
- Internal procedure; Electrical method; At permanent location (S) and outside of it (P) — 2 calibration items
- Internal procedure; Method using reference materials; At permanent location (S) and outside of it (P) — 2 calibration items
Certificate information
- Issue date
- 26.10.2026
- Issue no.
- 19
- Certificate date
- 02.08.2023
- Accreditation cycle
- 06.11.2025 — 06.12.2029
- Approved by
- Tadeusz Matras
Accreditation scope — calibration items (37)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | pH meters | Calibration — pH - pH — 0 to 14 · CMC 0,002 - DC voltage — -2000 mV to 2000 mV · CMC 0,2 mV pH |
Internal procedure; Electrical method; At permanent location (S) and outside of it (P) | Internal procedure PP.03.03 | |
| 2 | pH meters | Calibration — pH - pH — 1 to 13 · CMC 0,02 pH |
Internal procedure; Method using reference materials; At permanent location (S) and outside of it (P) | Internal procedure PP.03.03 | |
| 3 | Conductivity meters | Calibration — Electrolytic conductivity (conductometry) 0,15 mS/cm to 115 mS/cm · CMC 0,5 % Electrolytic conductivity (conductometry) |
Internal procedure; Method using reference materials; At permanent location (S) and outside of it (P) | Internal procedure PP.03.04 | |
| 4 | Conductivity meters | Calibration — Electrolytic conductivity (conductometry) 0,2 µS/cm to 199,99 µS/cm · CMC 0,01 % 0,2 mS/cm to 1999,99 mS/cm · CMC 0,01 % Electrolytic conductivity (conductometry) |
Internal procedure; Electrical method; At permanent location (S) and outside of it (P) | Internal procedure PP.03.04 | |
| 5 | Flue gas analysers | Calibration — Volume fraction (gas analysis) NO — 0,1 µmol/mol to 10 µmol/mol · CMC 5% NO — 10 µmol/mol to 1000 µmol/mol · CMC 5% NO₂ — 0,1 µmol/mol to 10 µmol/mol · CMC 6% NO₂ — 10 µmol/mol to 1000 µmol/mol · CMC 6% CO — 0,1 µmol/mol to 10 µmol/mol · CMC 10 % CO — 10 µmol/mol to 1000 µmol/mol · CMC 10 % CO₂ — 3 µmol/mol to 500 mmol/mol · CMC 3% SO₂ — 0,1 µmol/mol to 10 µmol/mol · CMC 6% SO₂ — 10 µmol/mol to 1000 µmol/mol · CMC 6% O₂ — 5 µmol/mol to 220 mmol/mol · CMC 3% Volume fraction (gas analysis) |
Internal procedure; At permanent location (S) | Internal procedure PP.03.01 | |
| 6 | Gas concentration meters Oxygen meters |
Calibration — Volume fraction (gas analysis) O₂ — 0 % to 10 % · CMC 0,1 % O₂ — 10 % to 20 % · CMC 0,2 % O₂ — 20 % to 30 % · CMC 0,3 % O₂ — 30 % to 50 % · CMC 0,5 % O₂ — 50 % to 80 % · CMC 0,8 % O₂ — 80 % to 100 % · CMC 1,1 % Volume fraction (gas analysis) |
Internal procedure; At permanent location (S) | Internal procedure PP.03.02 | |
| 7 | Gauge blocks (classes K, 0, 1, 2) | Calibration — Length 0,5 mm to 100 mm · CMC Q[0,041; 0,11 ∙ 10⁻³ L] µm Length |
At permanent location (S) | PN-EN ISO 3650:2000 | |
| 8 | Vernier calipers | Calibration — Length 0 mm to 150 mm · CMC 19 µm 150 mm to 300 mm · CMC 27 µm Length |
At permanent location (S) | PN-EN ISO 13385-1:2019 | |
| 9 | Calibrators Digital voltmeters Multimeters |
Calibration — DC voltage 0V · CMC 0,1 µV 1 mV to 2,2 V · CMC 7 · 10⁻⁶ · U + 1 µV 2,2 V to 11 V · CMC 9 · 10⁻⁶ · U 11 V to 22 V · CMC 8 · 10⁻⁶ · U 22 V to 220 V · CMC 12 · 10⁻⁶ · U 220 V to 1000 V · CMC 12 · 10⁻⁶ · U DC voltage |
Direct and indirect method; At permanent location (S) and outside of it (P) | EURAMET cg-15 v.3.0 | |
| 10 | Analogue voltmeters | Calibration — DC voltage 0V · CMC 0,1 µV 1 mV to 2,2 V · CMC 7 · 10⁻⁶ · U + 1 µV 2,2 V to 11 V · CMC 9 · 10⁻⁶ · U 11 V to 22 V · CMC 8 · 10⁻⁶ · U 22 V to 220 V · CMC 12 · 10⁻⁶ · U 220 V to 1000 V · CMC 12 · 10⁻⁶ · U DC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure PP.07.01 | |
| 11 | Power supplies | Calibration — DC voltage 0V · CMC 0,1 µV 1 mV to 100 mV · CMC 8 · 10⁻⁶ · U + 1 µV 100 mV to 1 V · CMC 11 · 10⁻⁶ · U 1 V to 10 V · CMC 9 · 10⁻⁶ · U 10 V to 100 V · CMC 13 · 10⁻⁶ · U 100 V to 1000 V · CMC 16 · 10⁻⁶ · U DC voltage |
Direct method; At permanent location (S) and outside of it (P) | EURAMET cg-15 v.3.0 | |
| 12 | Calibrators Digital ammeters Multimeters Power supplies |
Calibration — DC current 0,1 µA to 1 µA · CMC 35 · 10⁻⁶ · I + 21 pA 1 µA to 10 µA · CMC 50 · 10⁻⁶ · I + 6 pA 10 µA to 100 µA · CMC 15 · 10⁻⁶ · I + 0,4 nA 100 µA to 320 mA · CMC 18 · 10⁻⁶ · I 320 mA to 1 A · CMC 15 · 10⁻⁶ · I + 6 µA 1 A to 10 A · CMC 0,2 · 10⁻³ · I 10 A to 150 A · CMC 0,3 · 10⁻³· I DC current |
Direct and indirect method; At permanent location (S) and outside of it (P) | EURAMET cg-15 v.3.0 | |
| 13 | Analogue ammeters | Calibration — DC current 0,1 µA to 1 µA · CMC 35 · 10⁻⁶ · I + 21 pA 1 µA to 10 µA · CMC 50 · 10⁻⁶ · I + 6 pA 10 µA to 100 µA · CMC 15 · 10⁻⁶ · I + 0,4 nA 100 µA to 320 mA · CMC 18 · 10⁻⁶ · I 320 mA to 1 A · CMC 15 · 10⁻⁶ · I + 6 µA 1 A to 10 A · CMC 0,2 · 10⁻³ · I 10 A to 150 A · CMC 0,3 · 10⁻³· I DC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure PP.07.01 | |
| 14 | Clamp meters | Calibration — DC current 1 mA to 2,2 A · CMC 1 · 10⁻³ · I 2,2 A to 20 A · CMC 2 · 10⁻³ · I 20 A to 1000 A · CMC 3 · 10⁻³ · I DC current |
Direct method; At permanent location (S) and outside of it (P) | EURAMET cg-15 v.3.0 | |
| 15 | Calibrators Digital voltmeters Multimeters |
Calibration — AC voltage 10 Hz to 20 Hz — 1 mV to 2,2 mV · CMC 0,52 · 10⁻³ · U 10 Hz to 20 Hz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 10 Hz to 20 Hz — 7 mV to 22 mV · CMC 80 · 10⁻⁶ · U 10 Hz to 20 Hz — 22 mV to 70 mV · CMC 70 · 10⁻⁶ · U 10 Hz to 20 Hz — 70 mV to 220 mV · CMC 39 · 10⁻⁶ · U 10 Hz to 20 Hz — 220 mV to 700 mV · CMC 25 · 10⁻⁶ · U 10 Hz to 20 Hz — 700 mV to 2,2V · CMC 20 · 10⁻⁶ · U 10 Hz to 20 Hz — 2,2 V to 7 V · CMC 18 · 10⁻⁶ · U 10 Hz to 20 Hz — 7 V to 22 V · CMC 17 · 10⁻⁶ · U 10 Hz to 20 Hz — 22 V to 70 V · CMC 18 · 10⁻⁶ · U 10 Hz to 20 Hz — 70 V to 220 V · CMC 19 · 10⁻⁶ · U 10 Hz to 20 Hz — 220 V to 1000 V · CMC 25 · 10⁻⁶ · U 20 Hz to 40 Hz — 1 mV to 2,2 mV · CMC 0,52 · 10⁻³ · U 20 Hz to 40 Hz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 20 Hz to 40 Hz — 7 mV to 22 mV · CMC 80 · 10⁻⁶ · U 20 Hz to 40 Hz — 22 mV to 70 mV · CMC 58 · 10⁻⁶ · U 20 Hz to 40 Hz — 70 mV to 220 mV · CMC 35 · 10⁻⁶ · U 20 Hz to 40 Hz — 220 mV to 700 mV · CMC 22 · 10⁻⁶ · U 20 Hz to 40 Hz — 700 mV to 2,2 V · CMC 14 · 10⁻⁶ · U 20 Hz to 40 Hz — 2,2 V to 7 V · CMC 12 · 10⁻⁶ · U 20 Hz to 40 Hz — 7 V to 22 V · CMC 16 · 10⁻⁶ · U 20 Hz to 40 Hz — 22 V to 70 V · CMC 16 · 10⁻⁶ · U 20 Hz to 40 Hz — 70 V to 220 V · CMC 18 · 10⁻⁶ · U 20 Hz to 40 Hz — 220 V to 1000 V · CMC 27 · 10⁻⁶ · U 40 Hz to 20 kHz — 1 mV to 2,2 mV · CMC 0,4 · 10⁻³ · U 40 Hz to 20 kHz — 2,2 mV to 7 mV · CMC 0,16 · 10⁻³ · U 40 Hz to 20 kHz — 7 mV to 22 mV · CMC 65 · 10⁻⁶ · U 40 Hz to 20 kHz — 22 mV to 70 mV · CMC 35 · 10⁻⁶ · U 40 Hz to 20 kHz — 70 mV to 220 mV · CMC 25 · 10⁻⁶ · U 40 Hz to 20 kHz — 220 mV to 700 mV · CMC 12 · 10⁻⁶ · U 40 Hz to 20 kHz — 700 mV to 2,2 V · CMC 10 · 10⁻⁶ · U 40 Hz to 20 kHz — 2,2 V to 7 V · CMC 11 · 10⁻⁶ · U 40 Hz to 20 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 40 Hz to 20 kHz — 22 V to 70 V · CMC 15 · 10⁻⁶ · U 40 Hz to 20 kHz — 70 V to 220 V · CMC 17 · 10⁻⁶ · U 40 Hz to 20 kHz — 220 V to 1000 V · CMC 45 · 10⁻⁶ · U 20 kHz to 50 kHz — 1 mV to 2,2 mV · CMC 0,4 · 10⁻⁶ · U 20 kHz to 50 kHz — 2,2 mV to 7 mV · CMC 0,16 · 10⁻⁶ · U 20 kHz to 50 kHz — 7 mV to 22 mV · CMC 75 · 10⁻⁶ · U 20 kHz to 50 kHz — 22 mV to 70 mV · CMC 35 · 10⁻⁶ · U 20 kHz to 50 kHz — 70 mV to 220 mV · CMC 25 · 10⁻⁶ · U 20 kHz to 50 kHz — 220 mV to 700 mV · CMC 12 · 10⁻⁶ · U 20 kHz to 50 kHz — 700 mV to 2,2V · CMC 10 · 10⁻⁶ · U 20 kHz to 50 kHz — 2,2 V to 7 V · CMC 11 · 10⁻⁶ · U 20 kHz to 50 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 20 kHz to 50 kHz — 22 V to 70 V · CMC 15 · 10⁻⁶ · U 20 kHz to 50 kHz — 70 V to 220 V · CMC 27 · 10⁻⁶ · U 20 kHz to 50 kHz — 220 V to 1000 V · CMC 45 · 10⁻⁶ · U AC voltage |
Direct and indirect method; At permanent location (S) and outside of it (P) | EURAMET cg-15 v.3.0 | |
| 16 | Analogue voltmeters | Calibration — AC voltage 10 Hz to 20 Hz — 1 mV to 2,2 mV · CMC 0,52 · 10⁻³ · U 10 Hz to 20 Hz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 10 Hz to 20 Hz — 7 mV to 22 mV · CMC 80 · 10⁻⁶ · U 10 Hz to 20 Hz — 22 mV to 70 mV · CMC 70 · 10⁻⁶ · U 10 Hz to 20 Hz — 70 mV to 220 mV · CMC 39 · 10⁻⁶ · U 10 Hz to 20 Hz — 220 mV to 700 mV · CMC 25 · 10⁻⁶ · U 10 Hz to 20 Hz — 700 mV to 2,2V · CMC 20 · 10⁻⁶ · U 10 Hz to 20 Hz — 2,2 V to 7 V · CMC 18 · 10⁻⁶ · U 10 Hz to 20 Hz — 7 V to 22 V · CMC 17 · 10⁻⁶ · U 10 Hz to 20 Hz — 22 V to 70 V · CMC 18 · 10⁻⁶ · U 10 Hz to 20 Hz — 70 V to 220 V · CMC 19 · 10⁻⁶ · U 10 Hz to 20 Hz — 220 V to 1000 V · CMC 25 · 10⁻⁶ · U 20 Hz to 40 Hz — 1 mV to 2,2 mV · CMC 0,52 · 10⁻³ · U 20 Hz to 40 Hz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 20 Hz to 40 Hz — 7 mV to 22 mV · CMC 80 · 10⁻⁶ · U 20 Hz to 40 Hz — 22 mV to 70 mV · CMC 58 · 10⁻⁶ · U 20 Hz to 40 Hz — 70 mV to 220 mV · CMC 35 · 10⁻⁶ · U 20 Hz to 40 Hz — 220 mV to 700 mV · CMC 22 · 10⁻⁶ · U 20 Hz to 40 Hz — 700 mV to 2,2 V · CMC 14 · 10⁻⁶ · U 20 Hz to 40 Hz — 2,2 V to 7 V · CMC 12 · 10⁻⁶ · U 20 Hz to 40 Hz — 7 V to 22 V · CMC 16 · 10⁻⁶ · U 20 Hz to 40 Hz — 22 V to 70 V · CMC 16 · 10⁻⁶ · U 20 Hz to 40 Hz — 70 V to 220 V · CMC 18 · 10⁻⁶ · U 20 Hz to 40 Hz — 220 V to 1000 V · CMC 27 · 10⁻⁶ · U 40 Hz to 20 kHz — 1 mV to 2,2 mV · CMC 0,4 · 10⁻³ · U 40 Hz to 20 kHz — 2,2 mV to 7 mV · CMC 0,16 · 10⁻³ · U 40 Hz to 20 kHz — 7 mV to 22 mV · CMC 65 · 10⁻⁶ · U 40 Hz to 20 kHz — 22 mV to 70 mV · CMC 35 · 10⁻⁶ · U 40 Hz to 20 kHz — 70 mV to 220 mV · CMC 25 · 10⁻⁶ · U 40 Hz to 20 kHz — 220 mV to 700 mV · CMC 12 · 10⁻⁶ · U 40 Hz to 20 kHz — 700 mV to 2,2 V · CMC 10 · 10⁻⁶ · U 40 Hz to 20 kHz — 2,2 V to 7 V · CMC 11 · 10⁻⁶ · U 40 Hz to 20 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 40 Hz to 20 kHz — 22 V to 70 V · CMC 15 · 10⁻⁶ · U 40 Hz to 20 kHz — 70 V to 220 V · CMC 17 · 10⁻⁶ · U 40 Hz to 20 kHz — 220 V to 1000 V · CMC 45 · 10⁻⁶ · U 20 kHz to 50 kHz — 1 mV to 2,2 mV · CMC 0,4 · 10⁻⁶ · U 20 kHz to 50 kHz — 2,2 mV to 7 mV · CMC 0,16 · 10⁻⁶ · U 20 kHz to 50 kHz — 7 mV to 22 mV · CMC 75 · 10⁻⁶ · U 20 kHz to 50 kHz — 22 mV to 70 mV · CMC 35 · 10⁻⁶ · U 20 kHz to 50 kHz — 70 mV to 220 mV · CMC 25 · 10⁻⁶ · U 20 kHz to 50 kHz — 220 mV to 700 mV · CMC 12 · 10⁻⁶ · U 20 kHz to 50 kHz — 700 mV to 2,2V · CMC 10 · 10⁻⁶ · U 20 kHz to 50 kHz — 2,2 V to 7 V · CMC 11 · 10⁻⁶ · U 20 kHz to 50 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 20 kHz to 50 kHz — 22 V to 70 V · CMC 15 · 10⁻⁶ · U 20 kHz to 50 kHz — 70 V to 220 V · CMC 27 · 10⁻⁶ · U 20 kHz to 50 kHz — 220 V to 1000 V · CMC 45 · 10⁻⁶ · U AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure PP.07.01 | |
| 17 | Calibrators Digital voltmeters Multimeters |
Calibration — AC voltage 50 kHz to 100 kHz — 1 mV to 2,2 mV · CMC 0,41 · 10⁻³ · U 50 kHz to 100 kHz — 2,2 mV to 7 mV · CMC 0,2 · 10⁻³ · U 50 kHz to 100 kHz — 7 mV to 22 mV · CMC 75 · 10⁻⁶ · U 50 kHz to 100 kHz — 22 mV to 70 mV · CMC 45 · 10⁻⁶ · U 50 kHz to 100 kHz — 70 mV to 220 mV · CMC 28 · 10⁻⁶ · U 50 kHz to 100 kHz — 220 mV to 700 mV · CMC 13 · 10⁻⁶ · U 50 kHz to 100 kHz — 700 mV to 2,2V · CMC 11 · 10⁻⁶ · U 50 kHz to 100 kHz — 2,2 V to 7 V · CMC 13 · 10⁻⁶ · U 50 kHz to 100 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 50 kHz to 100 kHz — 22 V to 70 V · CMC 25 · 10⁻⁶ · U 50 kHz to 100 kHz — 70 V to 220 V · CMC 32 · 10⁻⁶ · U 50 kHz to 100 kHz — 220 V to 1000 V · CMC 65 · 10⁻⁶ · U 100 kHz to 300 kHz — 1 mV to 2,2 mV · CMC 0,46 · 10⁻³ · U 100 kHz to 300 kHz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 100 kHz to 300 kHz — 7 mV to 22 mV · CMC 95 · 10⁻⁶ · U 100 kHz to 300 kHz — 22 mV to 70 mV · CMC 55 · 10⁻⁶ · U 100 kHz to 300 kHz — 70 mV to 220 mV · CMC 42 · 10⁻⁶ · U 100 kHz to 300 kHz — 220 mV to 700 mV · CMC 14 · 10⁻⁶ · U 100 kHz to 300 kHz — 700 mV to 2,2 V · CMC 11 · 10⁻⁶ · U 100 kHz to 300 kHz — 2,2 V to 7 V · CMC 13 · 10⁻⁶ · U 100 kHz to 300 kHz — 7 V to 22 V · CMC 25 · 10⁻⁶ · U 100 kHz to 300 kHz — 22 V to 70 V · CMC 25 · 10⁻⁶ · U 300 kHz to 500 kHz — 1 mV to 2,2 mV · CMC 0,55 · 10⁻³ · U 300 kHz to 500 kHz — 2,2 mV to 7 mV · CMC 0,33 · 10⁻³ · U 300 kHz to 500 kHz — 7 mV to 22 mV · CMC 0,19 · 10⁻³ · U 300 kHz to 500 kHz — 22 mV to 70 mV · CMC 0,11 · 10⁻³ · U 300 kHz to 500 kHz — 70 mV to 220 mV · CMC 85 · 10⁻⁶ · U 300 kHz to 500 kHz — 220 mV to 700 mV · CMC 27 · 10⁻⁶ · U 300 kHz to 500 kHz — 700 mV to 2,2 V · CMC 22 · 10⁻⁶ · U 300 kHz to 500 kHz — 2,2 V to 7 V · CMC 30 · 10⁻⁶ · U 300 kHz to 500 kHz — 7 V to 22 V · CMC 30 · 10⁻⁶ · U 300 kHz to 500 kHz — 22 V to 70 V · CMC 40 · 10⁻⁶ · U 500 kHz to 1 MHz — 1 mV to 2,2 mV · CMC 0,60 · 10⁻³ · U 500 kHz to 1 MHz — 2,2 mV to 7 mV · CMC 0,45 · 10⁻³ · U 500 kHz to 1 MHz — 7 mV to 22 mV · CMC 0,21 · 10⁻³ · U 500 kHz to 1 MHz — 22 mV to 70 mV · CMC 0,23 · 10⁻³ · U 500 kHz to 1 MHz — 70 mV to 220 mV · CMC 0,1 · 10⁻³ · U 500 kHz to 1 MHz — 220 mV to 700 mV · CMC 40 · 10⁻⁶ · U 500 kHz to 1 MHz — 700 mV to 2,2 V · CMC 68 · 10⁻⁶ · U 500 kHz to 1 MHz — 2,2 V to 7 V · CMC 95 · 10⁻⁶ · U 500 kHz to 1 MHz — 7 V to 22 V · CMC 0,11 · 10⁻³ · U 500 kHz to 1 MHz — 22 V to 70 V · CMC 0,13 · 10⁻³ · U AC voltage |
Direct and indirect method; At permanent location (S) and outside of it (P) | EURAMET cg-15 v.3.0 | |
| 18 | Analogue voltmeters | Calibration — AC voltage 50 kHz to 100 kHz — 1 mV to 2,2 mV · CMC 0,41 · 10⁻³ · U 50 kHz to 100 kHz — 2,2 mV to 7 mV · CMC 0,2 · 10⁻³ · U 50 kHz to 100 kHz — 7 mV to 22 mV · CMC 75 · 10⁻⁶ · U 50 kHz to 100 kHz — 22 mV to 70 mV · CMC 45 · 10⁻⁶ · U 50 kHz to 100 kHz — 70 mV to 220 mV · CMC 28 · 10⁻⁶ · U 50 kHz to 100 kHz — 220 mV to 700 mV · CMC 13 · 10⁻⁶ · U 50 kHz to 100 kHz — 700 mV to 2,2V · CMC 11 · 10⁻⁶ · U 50 kHz to 100 kHz — 2,2 V to 7 V · CMC 13 · 10⁻⁶ · U 50 kHz to 100 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 50 kHz to 100 kHz — 22 V to 70 V · CMC 25 · 10⁻⁶ · U 50 kHz to 100 kHz — 70 V to 220 V · CMC 32 · 10⁻⁶ · U 50 kHz to 100 kHz — 220 V to 1000 V · CMC 65 · 10⁻⁶ · U 100 kHz to 300 kHz — 1 mV to 2,2 mV · CMC 0,46 · 10⁻³ · U 100 kHz to 300 kHz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 100 kHz to 300 kHz — 7 mV to 22 mV · CMC 95 · 10⁻⁶ · U 100 kHz to 300 kHz — 22 mV to 70 mV · CMC 55 · 10⁻⁶ · U 100 kHz to 300 kHz — 70 mV to 220 mV · CMC 42 · 10⁻⁶ · U 100 kHz to 300 kHz — 220 mV to 700 mV · CMC 14 · 10⁻⁶ · U 100 kHz to 300 kHz — 700 mV to 2,2 V · CMC 11 · 10⁻⁶ · U 100 kHz to 300 kHz — 2,2 V to 7 V · CMC 13 · 10⁻⁶ · U 100 kHz to 300 kHz — 7 V to 22 V · CMC 25 · 10⁻⁶ · U 100 kHz to 300 kHz — 22 V to 70 V · CMC 25 · 10⁻⁶ · U 300 kHz to 500 kHz — 1 mV to 2,2 mV · CMC 0,55 · 10⁻³ · U 300 kHz to 500 kHz — 2,2 mV to 7 mV · CMC 0,33 · 10⁻³ · U 300 kHz to 500 kHz — 7 mV to 22 mV · CMC 0,19 · 10⁻³ · U 300 kHz to 500 kHz — 22 mV to 70 mV · CMC 0,11 · 10⁻³ · U 300 kHz to 500 kHz — 70 mV to 220 mV · CMC 85 · 10⁻⁶ · U 300 kHz to 500 kHz — 220 mV to 700 mV · CMC 27 · 10⁻⁶ · U 300 kHz to 500 kHz — 700 mV to 2,2 V · CMC 22 · 10⁻⁶ · U 300 kHz to 500 kHz — 2,2 V to 7 V · CMC 30 · 10⁻⁶ · U 300 kHz to 500 kHz — 7 V to 22 V · CMC 30 · 10⁻⁶ · U 300 kHz to 500 kHz — 22 V to 70 V · CMC 40 · 10⁻⁶ · U 500 kHz to 1 MHz — 1 mV to 2,2 mV · CMC 0,60 · 10⁻³ · U 500 kHz to 1 MHz — 2,2 mV to 7 mV · CMC 0,45 · 10⁻³ · U 500 kHz to 1 MHz — 7 mV to 22 mV · CMC 0,21 · 10⁻³ · U 500 kHz to 1 MHz — 22 mV to 70 mV · CMC 0,23 · 10⁻³ · U 500 kHz to 1 MHz — 70 mV to 220 mV · CMC 0,1 · 10⁻³ · U 500 kHz to 1 MHz — 220 mV to 700 mV · CMC 40 · 10⁻⁶ · U 500 kHz to 1 MHz — 700 mV to 2,2 V · CMC 68 · 10⁻⁶ · U 500 kHz to 1 MHz — 2,2 V to 7 V · CMC 95 · 10⁻⁶ · U 500 kHz to 1 MHz — 7 V to 22 V · CMC 0,11 · 10⁻³ · U 500 kHz to 1 MHz — 22 V to 70 V · CMC 0,13 · 10⁻³ · U AC voltage |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure PP.07.01 | |
| 19 | Calibrators Digital ammeters Multimeters |
Calibration — AC current 10 Hz to 40 Hz — 100 µA to 1 mA · CMC 12 · 10⁻⁵ · I 10 Hz to 40 Hz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 10 Hz to 40 Hz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 10 Hz to 40 Hz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 10 Hz to 40 Hz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I 40 Hz to 1 kHz — 100 µA to 1 mA · CMC 16 · 10⁻⁵ · I 40 Hz to 1 kHz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 40 Hz to 1 kHz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 40 Hz to 1 kHz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 40 Hz to 1 kHz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I 1 kHz to 10 kHz — 100 µA to 1 mA · CMC 60 · 10⁻⁶ · I 1 kHz to 10 kHz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 1 kHz to 10 kHz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 1 kHz to 10 kHz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 1 kHz to 10 kHz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I AC current |
Direct and indirect method; At permanent location (S) and outside of it (P) | EURAMET cg-15 v.3.0 | |
| 20 | Analogue ammeters | Calibration — AC current 10 Hz to 40 Hz — 100 µA to 1 mA · CMC 12 · 10⁻⁵ · I 10 Hz to 40 Hz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 10 Hz to 40 Hz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 10 Hz to 40 Hz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 10 Hz to 40 Hz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I 40 Hz to 1 kHz — 100 µA to 1 mA · CMC 16 · 10⁻⁵ · I 40 Hz to 1 kHz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 40 Hz to 1 kHz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 40 Hz to 1 kHz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 40 Hz to 1 kHz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I 1 kHz to 10 kHz — 100 µA to 1 mA · CMC 60 · 10⁻⁶ · I 1 kHz to 10 kHz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 1 kHz to 10 kHz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 1 kHz to 10 kHz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 1 kHz to 10 kHz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I AC current |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure PP.07.01 | |
| 21 | Clamp meters | Calibration — AC current 40 Hz to 5 kHz — 1 mA to 2,2 A · CMC 2 · 10⁻³ · I 40 Hz to 5 kHz — 2,2 A to 20 A · CMC 3 · 10⁻³ · I 40 Hz to 5 kHz — 20 A to 800 A · CMC 4 · 10⁻³ · I AC current |
Direct method; At permanent location (S) and outside of it (P) | EURAMET cg-15 v.3.0 | |
| 22 | Calibrators Digital ohmmeters Multimeters |
Calibration — DC resistance 1 Ω to 11 Ω · CMC 0,12 · 10⁻³· R 11 Ω to 33 Ω · CMC 33 · 10⁻⁶ · R 33 Ω to 110 Ω · CMC 29 · 10⁻⁶ · R 110 Ω to 330 Ω · CMC 28 · 10⁻⁶ · R 330 Ω to 1,1 kΩ · CMC 28 · 10⁻⁶ · R 1,1 kΩ to 3,3 kΩ · CMC 28 · 10⁻⁶ · R 3,3 kΩ to 11 kΩ · CMC 28 · 10⁻⁶ · R 11 kΩ to 33 kΩ · CMC 28 · 10⁻⁶ · R 33 kΩ to 110 kΩ · CMC 28 · 10⁻⁶ · R 110 kΩ to 330 kΩ · CMC 32 · 10⁻⁶ · R 330 kΩ to 1,1 MΩ · CMC 33 · 10⁻⁶ · R 1,1 MΩ to 3,3 MΩ · CMC 62 · 10⁻⁶ · R 3,3 MΩ to 11 MΩ · CMC 0,13 · 10⁻³ · R 11 MΩ to 33 MΩ · CMC 0,25 · 10⁻³ · R 33 MΩ to 110 MΩ · CMC 0,5 · 10⁻³ · R 110 MΩ to 330 MΩ · CMC 3 · 10⁻³ · R 330 MΩ to 1,1 GΩ · CMC 15 · 10⁻³ · R DC resistance |
Direct and indirect method; At permanent location (S) and outside of it (P) | EURAMET cg-15 v.3.0 | |
| 23 | Analogue ohmmeters | Calibration — DC resistance 1 Ω to 11 Ω · CMC 0,12 · 10⁻³· R 11 Ω to 33 Ω · CMC 33 · 10⁻⁶ · R 33 Ω to 110 Ω · CMC 29 · 10⁻⁶ · R 110 Ω to 330 Ω · CMC 28 · 10⁻⁶ · R 330 Ω to 1,1 kΩ · CMC 28 · 10⁻⁶ · R 1,1 kΩ to 3,3 kΩ · CMC 28 · 10⁻⁶ · R 3,3 kΩ to 11 kΩ · CMC 28 · 10⁻⁶ · R 11 kΩ to 33 kΩ · CMC 28 · 10⁻⁶ · R 33 kΩ to 110 kΩ · CMC 28 · 10⁻⁶ · R 110 kΩ to 330 kΩ · CMC 32 · 10⁻⁶ · R 330 kΩ to 1,1 MΩ · CMC 33 · 10⁻⁶ · R 1,1 MΩ to 3,3 MΩ · CMC 62 · 10⁻⁶ · R 3,3 MΩ to 11 MΩ · CMC 0,13 · 10⁻³ · R 11 MΩ to 33 MΩ · CMC 0,25 · 10⁻³ · R 33 MΩ to 110 MΩ · CMC 0,5 · 10⁻³ · R 110 MΩ to 330 MΩ · CMC 3 · 10⁻³ · R 330 MΩ to 1,1 GΩ · CMC 15 · 10⁻³ · R DC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure PP.07.01 | |
| 24 | Temperature indicators (meters) for use with thermocouples | Calibration — Electrical simulation of quantities -200 °C to 1820 °C · CMC 0,15 °C Electrical simulation of quantities |
Indirect electrical method; At permanent location (S) and outside of it (P) | EURAMET cg-11 v.2.0 PN-EN 60584-1:2014-04 | |
| 25 | Temperature indicators (meters) for use with resistance sensors | Calibration — Electrical simulation of quantities -200 °C to 850 °C · CMC 0,05 °C Electrical simulation of quantities |
Indirect electrical method; At permanent location (S) and outside of it (P) | EURAMET cg-11 v.2.0 PN-EN 60751:2022 | |
| 26 | Anemometers | Calibration — Air velocity (flow – gases) 1 m/s to 5 m/s · CMC 0,15 m/s 5 m/s to 10 m/s · CMC 0,20 m/s 10 m/s to 20 m/s · CMC 0,30 m/s 20 m/s to 25 m/s · CMC 0,50 m/s Air velocity (flow – gases) |
Internal procedure; At permanent location (S) | Internal procedure PP.11.01 | |
| 27 | Torque wrenches | Calibration — Torque 1 N∙m to 3000 N∙m · CMC 0,9 % Torque |
At permanent location (S) | PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03 | |
| 28 | Torque screwdrivers | Calibration — Torque 1 N∙m to 10 N∙m · CMC 0,9 % Torque |
At permanent location (S) | PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03 | |
| 29 | Thermohygrometers Hygrometers |
Calibration — Relative humidity temperature range 5 °C to 10 °C — 5 %rh to 98 %rh · CMC 1,2 %rh temperature range 10 °C to 40 °C — 5 %rh to 98 %rh · CMC 0,8 %rh temperature range 40 °C to 90 °C — 5 %rh to 98 %rh · CMC 1,5 %rh Relative humidity |
Internal procedure; At permanent location (S) and outside of it (P) | Internal procedure PP.14.01 | |
| 30 | Climatic chambers | Calibration — Relative humidity temperature range 5 °C to 90 °C — 5 %rh to 98 %rh · CMC 1,5 %rh Relative humidity |
At permanent location (S) and outside of it (P) | EURAMET cg-20 v. 5.0 | |
| 31 | Non-automatic electronic weighing instruments | Calibration — Mass (weighing instruments) up to 500 g · CMC 2,0 · 10⁻⁴ % 500 g do 20 kg · CMC 1,1 · 10⁻³ % 20 kg do 60 kg · CMC 3,3 · 10⁻² % Mass (weighing instruments) |
At permanent location (S) and outside of it (P) | EURAMET cg-18 v. 4.0 | |
| 32 | Barometers | Calibration — Pressure 700 hPa to 1200 hPa · CMC 0,25 hPa Pressure |
Direct method; At permanent location (S) and outside of it (P) | EURAMET cg-17 v.4.1 | |
| 33 | Electronic pressure gauges Pressure transmitters |
Calibration — Pressure -0,1 MPa to 0 MPa · CMC 0,00003 MPa 0 MPa do 0,5 MPa · CMC 0,00004 MPa 0,5 MPa do 1 MPa · CMC 0,00013 MPa 1 MPa do 1,5 MPa · CMC 0,00017 MPa 1,5 MPa do 2 MPa · CMC 0,00027 MPa 2 MPa do 12,5 MPa · CMC 0,0032 MPa 12,5 MPa do 25 MPa · CMC 0,0040 MPa 25 MPa do 37,5 MPa · CMC 0,0047 MPa 37,5 MPa do 50 MPa · CMC 0,0060 MPa 50 MPa do 62,5 MPa · CMC 0,0070 MPa 62,5 MPa do 75 MPa · CMC 0,0080 MPa 75 MPa do 87,5 MPa · CMC 0,0090 MPa 87,5 MPa do 100 MPa · CMC 0,011 MPa Pressure |
Direct method; At permanent location (S) and outside of it (P) | EURAMET cg-17 v.4.1 | |
| 34 | Electrical thermometers (including electronic) | Calibration — Temperature (electrical thermometry) -90 °C to 100 °C · CMC 0,05 °C 100 °C to 160 °C · CMC 0,08 °C 160 °C to 200 °C · CMC 0,15 °C 200 °C to 250 °C · CMC 0,25 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) and outside of it (P) | Internal procedure PP.19.01 | |
| 35 | Climatic chambers Thermostatic chambers |
Calibration — Temperature (electrical thermometry) -80 °C to 200 °C · CMC 0,5 °C Temperature (electrical thermometry) |
At permanent location (S) and outside of it (P) | EURAMET cg-20 v. 5.0 | |
| 36 | Steam sterilisation chambers (e.g. autoclaves) | Calibration — Temperature (electrical thermometry) 0 °C to 150 °C · CMC 0,9 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) and outside of it (P) | Internal procedure PP.14.19.01 | |
| 37 | Pyrometers (including radiation pyrometers, thermal imaging cameras) | Calibration — Temperature (radiation thermometry) -15 °C to 50 °C · CMC 0,5 °C 50 °C to 120 °C · CMC 0,8 °C 120 °C to 300 °C · CMC 1,5 °C 300 °C to 500 °C · CMC 2,5 °C Temperature (radiation thermometry) |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure PP.19.03 | |
Reference standards (21)
EURAMET cg-11 v.2.0
EURAMET cg-15 v.3.0
EURAMET cg-17 v.4.1
EURAMET cg-18 v. 4.0
EURAMET cg-20 v. 5.0
PN-EN 60584-1:2014-04
PN-EN 60751:2022
PN-EN ISO 13385-1:2019
PN-EN ISO 3650:2000
PN-EN ISO 6789-1:2017-03
PN-EN ISO 6789-2:2017-03
PP.03.01
PP.03.02
PP.03.03
PP.03.04
PP.07.01
PP.11.01
PP.14.01
PP.14.19.01
PP.19.01
PP.19.03