🇵🇱 Testo Industrial Services sp. z o.o. PL

PCA AP 176 • Warszawa, Poland • 37 calibration items

Metrology & calibration

Testo Industrial Services sp. z o.o. is a calibration laboratory accredited by PCA under number AP 176 (Warszawa, Poland). Its accreditation scope covers 37 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Multimeters, Analogue voltmeters, Digital voltmeters. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S) and ou…, Direct and indirect method; At permanent location (S) and outside o…, Direct method; At permanent location (S) and outside of it (P).

At a glance

  • Accreditation number: PCA AP 176
  • Calibration items in scope: 37
  • Types of calibrated items: 33
  • Calibration principles used: 10
  • City: Warszawa, Poland
  • Valid until: 06-12-2029
Accreditation number
AP 176
Accreditation body
PCA
Address
Aleja Krakowska 2A, 02-284 Warszawa
City
Warszawa, Poland
Valid until
06-12-2029

What this laboratory calibrates (33)

Calibration principles (10)

Certificate information

Issue date
26.10.2026
Issue no.
19
Certificate date
02.08.2023
Accreditation cycle
06.11.2025 — 06.12.2029
Approved by
Tadeusz Matras

Accreditation scope — calibration items (37)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 pH meters Calibration — pH
- pH — 0 to 14 · CMC 0,002 - DC voltage — -2000 mV to 2000 mV · CMC 0,2 mV
pH
Internal procedure; Electrical method; At permanent location (S) and outside of it (P) Internal procedure PP.03.03
2 pH meters Calibration — pH
- pH — 1 to 13 · CMC 0,02
pH
Internal procedure; Method using reference materials; At permanent location (S) and outside of it (P) Internal procedure PP.03.03
3 Conductivity meters Calibration — Electrolytic conductivity (conductometry)
0,15 mS/cm to 115 mS/cm · CMC 0,5 %
Electrolytic conductivity (conductometry)
Internal procedure; Method using reference materials; At permanent location (S) and outside of it (P) Internal procedure PP.03.04
4 Conductivity meters Calibration — Electrolytic conductivity (conductometry)
0,2 µS/cm to 199,99 µS/cm · CMC 0,01 % 0,2 mS/cm to 1999,99 mS/cm · CMC 0,01 %
Electrolytic conductivity (conductometry)
Internal procedure; Electrical method; At permanent location (S) and outside of it (P) Internal procedure PP.03.04
5 Flue gas analysers Calibration — Volume fraction (gas analysis)
NO — 0,1 µmol/mol to 10 µmol/mol · CMC 5% NO — 10 µmol/mol to 1000 µmol/mol · CMC 5% NO₂ — 0,1 µmol/mol to 10 µmol/mol · CMC 6% NO₂ — 10 µmol/mol to 1000 µmol/mol · CMC 6% CO — 0,1 µmol/mol to 10 µmol/mol · CMC 10 % CO — 10 µmol/mol to 1000 µmol/mol · CMC 10 % CO₂ — 3 µmol/mol to 500 mmol/mol · CMC 3% SO₂ — 0,1 µmol/mol to 10 µmol/mol · CMC 6% SO₂ — 10 µmol/mol to 1000 µmol/mol · CMC 6% O₂ — 5 µmol/mol to 220 mmol/mol · CMC 3%
Volume fraction (gas analysis)
Internal procedure; At permanent location (S) Internal procedure PP.03.01
6 Gas concentration meters
Oxygen meters
Calibration — Volume fraction (gas analysis)
O₂ — 0 % to 10 % · CMC 0,1 % O₂ — 10 % to 20 % · CMC 0,2 % O₂ — 20 % to 30 % · CMC 0,3 % O₂ — 30 % to 50 % · CMC 0,5 % O₂ — 50 % to 80 % · CMC 0,8 % O₂ — 80 % to 100 % · CMC 1,1 %
Volume fraction (gas analysis)
Internal procedure; At permanent location (S) Internal procedure PP.03.02
7 Gauge blocks (classes K, 0, 1, 2) Calibration — Length
0,5 mm to 100 mm · CMC Q[0,041; 0,11 ∙ 10⁻³ L] µm
Length
At permanent location (S) PN-EN ISO 3650:2000
8 Vernier calipers Calibration — Length
0 mm to 150 mm · CMC 19 µm 150 mm to 300 mm · CMC 27 µm
Length
At permanent location (S) PN-EN ISO 13385-1:2019
9 Calibrators
Digital voltmeters
Multimeters
Calibration — DC voltage
0V · CMC 0,1 µV 1 mV to 2,2 V · CMC 7 · 10⁻⁶ · U + 1 µV 2,2 V to 11 V · CMC 9 · 10⁻⁶ · U 11 V to 22 V · CMC 8 · 10⁻⁶ · U 22 V to 220 V · CMC 12 · 10⁻⁶ · U 220 V to 1000 V · CMC 12 · 10⁻⁶ · U
DC voltage
Direct and indirect method; At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0
10 Analogue voltmeters Calibration — DC voltage
0V · CMC 0,1 µV 1 mV to 2,2 V · CMC 7 · 10⁻⁶ · U + 1 µV 2,2 V to 11 V · CMC 9 · 10⁻⁶ · U 11 V to 22 V · CMC 8 · 10⁻⁶ · U 22 V to 220 V · CMC 12 · 10⁻⁶ · U 220 V to 1000 V · CMC 12 · 10⁻⁶ · U
DC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP.07.01
11 Power supplies Calibration — DC voltage
0V · CMC 0,1 µV 1 mV to 100 mV · CMC 8 · 10⁻⁶ · U + 1 µV 100 mV to 1 V · CMC 11 · 10⁻⁶ · U 1 V to 10 V · CMC 9 · 10⁻⁶ · U 10 V to 100 V · CMC 13 · 10⁻⁶ · U 100 V to 1000 V · CMC 16 · 10⁻⁶ · U
DC voltage
Direct method; At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0
12 Calibrators
Digital ammeters
Multimeters
Power supplies
Calibration — DC current
0,1 µA to 1 µA · CMC 35 · 10⁻⁶ · I + 21 pA 1 µA to 10 µA · CMC 50 · 10⁻⁶ · I + 6 pA 10 µA to 100 µA · CMC 15 · 10⁻⁶ · I + 0,4 nA 100 µA to 320 mA · CMC 18 · 10⁻⁶ · I 320 mA to 1 A · CMC 15 · 10⁻⁶ · I + 6 µA 1 A to 10 A · CMC 0,2 · 10⁻³ · I 10 A to 150 A · CMC 0,3 · 10⁻³· I
DC current
Direct and indirect method; At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0
13 Analogue ammeters Calibration — DC current
0,1 µA to 1 µA · CMC 35 · 10⁻⁶ · I + 21 pA 1 µA to 10 µA · CMC 50 · 10⁻⁶ · I + 6 pA 10 µA to 100 µA · CMC 15 · 10⁻⁶ · I + 0,4 nA 100 µA to 320 mA · CMC 18 · 10⁻⁶ · I 320 mA to 1 A · CMC 15 · 10⁻⁶ · I + 6 µA 1 A to 10 A · CMC 0,2 · 10⁻³ · I 10 A to 150 A · CMC 0,3 · 10⁻³· I
DC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP.07.01
14 Clamp meters Calibration — DC current
1 mA to 2,2 A · CMC 1 · 10⁻³ · I 2,2 A to 20 A · CMC 2 · 10⁻³ · I 20 A to 1000 A · CMC 3 · 10⁻³ · I
DC current
Direct method; At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0
15 Calibrators
Digital voltmeters
Multimeters
Calibration — AC voltage
10 Hz to 20 Hz — 1 mV to 2,2 mV · CMC 0,52 · 10⁻³ · U 10 Hz to 20 Hz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 10 Hz to 20 Hz — 7 mV to 22 mV · CMC 80 · 10⁻⁶ · U 10 Hz to 20 Hz — 22 mV to 70 mV · CMC 70 · 10⁻⁶ · U 10 Hz to 20 Hz — 70 mV to 220 mV · CMC 39 · 10⁻⁶ · U 10 Hz to 20 Hz — 220 mV to 700 mV · CMC 25 · 10⁻⁶ · U 10 Hz to 20 Hz — 700 mV to 2,2V · CMC 20 · 10⁻⁶ · U 10 Hz to 20 Hz — 2,2 V to 7 V · CMC 18 · 10⁻⁶ · U 10 Hz to 20 Hz — 7 V to 22 V · CMC 17 · 10⁻⁶ · U 10 Hz to 20 Hz — 22 V to 70 V · CMC 18 · 10⁻⁶ · U 10 Hz to 20 Hz — 70 V to 220 V · CMC 19 · 10⁻⁶ · U 10 Hz to 20 Hz — 220 V to 1000 V · CMC 25 · 10⁻⁶ · U 20 Hz to 40 Hz — 1 mV to 2,2 mV · CMC 0,52 · 10⁻³ · U 20 Hz to 40 Hz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 20 Hz to 40 Hz — 7 mV to 22 mV · CMC 80 · 10⁻⁶ · U 20 Hz to 40 Hz — 22 mV to 70 mV · CMC 58 · 10⁻⁶ · U 20 Hz to 40 Hz — 70 mV to 220 mV · CMC 35 · 10⁻⁶ · U 20 Hz to 40 Hz — 220 mV to 700 mV · CMC 22 · 10⁻⁶ · U 20 Hz to 40 Hz — 700 mV to 2,2 V · CMC 14 · 10⁻⁶ · U 20 Hz to 40 Hz — 2,2 V to 7 V · CMC 12 · 10⁻⁶ · U 20 Hz to 40 Hz — 7 V to 22 V · CMC 16 · 10⁻⁶ · U 20 Hz to 40 Hz — 22 V to 70 V · CMC 16 · 10⁻⁶ · U 20 Hz to 40 Hz — 70 V to 220 V · CMC 18 · 10⁻⁶ · U 20 Hz to 40 Hz — 220 V to 1000 V · CMC 27 · 10⁻⁶ · U 40 Hz to 20 kHz — 1 mV to 2,2 mV · CMC 0,4 · 10⁻³ · U 40 Hz to 20 kHz — 2,2 mV to 7 mV · CMC 0,16 · 10⁻³ · U 40 Hz to 20 kHz — 7 mV to 22 mV · CMC 65 · 10⁻⁶ · U 40 Hz to 20 kHz — 22 mV to 70 mV · CMC 35 · 10⁻⁶ · U 40 Hz to 20 kHz — 70 mV to 220 mV · CMC 25 · 10⁻⁶ · U 40 Hz to 20 kHz — 220 mV to 700 mV · CMC 12 · 10⁻⁶ · U 40 Hz to 20 kHz — 700 mV to 2,2 V · CMC 10 · 10⁻⁶ · U 40 Hz to 20 kHz — 2,2 V to 7 V · CMC 11 · 10⁻⁶ · U 40 Hz to 20 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 40 Hz to 20 kHz — 22 V to 70 V · CMC 15 · 10⁻⁶ · U 40 Hz to 20 kHz — 70 V to 220 V · CMC 17 · 10⁻⁶ · U 40 Hz to 20 kHz — 220 V to 1000 V · CMC 45 · 10⁻⁶ · U 20 kHz to 50 kHz — 1 mV to 2,2 mV · CMC 0,4 · 10⁻⁶ · U 20 kHz to 50 kHz — 2,2 mV to 7 mV · CMC 0,16 · 10⁻⁶ · U 20 kHz to 50 kHz — 7 mV to 22 mV · CMC 75 · 10⁻⁶ · U 20 kHz to 50 kHz — 22 mV to 70 mV · CMC 35 · 10⁻⁶ · U 20 kHz to 50 kHz — 70 mV to 220 mV · CMC 25 · 10⁻⁶ · U 20 kHz to 50 kHz — 220 mV to 700 mV · CMC 12 · 10⁻⁶ · U 20 kHz to 50 kHz — 700 mV to 2,2V · CMC 10 · 10⁻⁶ · U 20 kHz to 50 kHz — 2,2 V to 7 V · CMC 11 · 10⁻⁶ · U 20 kHz to 50 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 20 kHz to 50 kHz — 22 V to 70 V · CMC 15 · 10⁻⁶ · U 20 kHz to 50 kHz — 70 V to 220 V · CMC 27 · 10⁻⁶ · U 20 kHz to 50 kHz — 220 V to 1000 V · CMC 45 · 10⁻⁶ · U
AC voltage
Direct and indirect method; At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0
16 Analogue voltmeters Calibration — AC voltage
10 Hz to 20 Hz — 1 mV to 2,2 mV · CMC 0,52 · 10⁻³ · U 10 Hz to 20 Hz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 10 Hz to 20 Hz — 7 mV to 22 mV · CMC 80 · 10⁻⁶ · U 10 Hz to 20 Hz — 22 mV to 70 mV · CMC 70 · 10⁻⁶ · U 10 Hz to 20 Hz — 70 mV to 220 mV · CMC 39 · 10⁻⁶ · U 10 Hz to 20 Hz — 220 mV to 700 mV · CMC 25 · 10⁻⁶ · U 10 Hz to 20 Hz — 700 mV to 2,2V · CMC 20 · 10⁻⁶ · U 10 Hz to 20 Hz — 2,2 V to 7 V · CMC 18 · 10⁻⁶ · U 10 Hz to 20 Hz — 7 V to 22 V · CMC 17 · 10⁻⁶ · U 10 Hz to 20 Hz — 22 V to 70 V · CMC 18 · 10⁻⁶ · U 10 Hz to 20 Hz — 70 V to 220 V · CMC 19 · 10⁻⁶ · U 10 Hz to 20 Hz — 220 V to 1000 V · CMC 25 · 10⁻⁶ · U 20 Hz to 40 Hz — 1 mV to 2,2 mV · CMC 0,52 · 10⁻³ · U 20 Hz to 40 Hz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 20 Hz to 40 Hz — 7 mV to 22 mV · CMC 80 · 10⁻⁶ · U 20 Hz to 40 Hz — 22 mV to 70 mV · CMC 58 · 10⁻⁶ · U 20 Hz to 40 Hz — 70 mV to 220 mV · CMC 35 · 10⁻⁶ · U 20 Hz to 40 Hz — 220 mV to 700 mV · CMC 22 · 10⁻⁶ · U 20 Hz to 40 Hz — 700 mV to 2,2 V · CMC 14 · 10⁻⁶ · U 20 Hz to 40 Hz — 2,2 V to 7 V · CMC 12 · 10⁻⁶ · U 20 Hz to 40 Hz — 7 V to 22 V · CMC 16 · 10⁻⁶ · U 20 Hz to 40 Hz — 22 V to 70 V · CMC 16 · 10⁻⁶ · U 20 Hz to 40 Hz — 70 V to 220 V · CMC 18 · 10⁻⁶ · U 20 Hz to 40 Hz — 220 V to 1000 V · CMC 27 · 10⁻⁶ · U 40 Hz to 20 kHz — 1 mV to 2,2 mV · CMC 0,4 · 10⁻³ · U 40 Hz to 20 kHz — 2,2 mV to 7 mV · CMC 0,16 · 10⁻³ · U 40 Hz to 20 kHz — 7 mV to 22 mV · CMC 65 · 10⁻⁶ · U 40 Hz to 20 kHz — 22 mV to 70 mV · CMC 35 · 10⁻⁶ · U 40 Hz to 20 kHz — 70 mV to 220 mV · CMC 25 · 10⁻⁶ · U 40 Hz to 20 kHz — 220 mV to 700 mV · CMC 12 · 10⁻⁶ · U 40 Hz to 20 kHz — 700 mV to 2,2 V · CMC 10 · 10⁻⁶ · U 40 Hz to 20 kHz — 2,2 V to 7 V · CMC 11 · 10⁻⁶ · U 40 Hz to 20 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 40 Hz to 20 kHz — 22 V to 70 V · CMC 15 · 10⁻⁶ · U 40 Hz to 20 kHz — 70 V to 220 V · CMC 17 · 10⁻⁶ · U 40 Hz to 20 kHz — 220 V to 1000 V · CMC 45 · 10⁻⁶ · U 20 kHz to 50 kHz — 1 mV to 2,2 mV · CMC 0,4 · 10⁻⁶ · U 20 kHz to 50 kHz — 2,2 mV to 7 mV · CMC 0,16 · 10⁻⁶ · U 20 kHz to 50 kHz — 7 mV to 22 mV · CMC 75 · 10⁻⁶ · U 20 kHz to 50 kHz — 22 mV to 70 mV · CMC 35 · 10⁻⁶ · U 20 kHz to 50 kHz — 70 mV to 220 mV · CMC 25 · 10⁻⁶ · U 20 kHz to 50 kHz — 220 mV to 700 mV · CMC 12 · 10⁻⁶ · U 20 kHz to 50 kHz — 700 mV to 2,2V · CMC 10 · 10⁻⁶ · U 20 kHz to 50 kHz — 2,2 V to 7 V · CMC 11 · 10⁻⁶ · U 20 kHz to 50 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 20 kHz to 50 kHz — 22 V to 70 V · CMC 15 · 10⁻⁶ · U 20 kHz to 50 kHz — 70 V to 220 V · CMC 27 · 10⁻⁶ · U 20 kHz to 50 kHz — 220 V to 1000 V · CMC 45 · 10⁻⁶ · U
AC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP.07.01
17 Calibrators
Digital voltmeters
Multimeters
Calibration — AC voltage
50 kHz to 100 kHz — 1 mV to 2,2 mV · CMC 0,41 · 10⁻³ · U 50 kHz to 100 kHz — 2,2 mV to 7 mV · CMC 0,2 · 10⁻³ · U 50 kHz to 100 kHz — 7 mV to 22 mV · CMC 75 · 10⁻⁶ · U 50 kHz to 100 kHz — 22 mV to 70 mV · CMC 45 · 10⁻⁶ · U 50 kHz to 100 kHz — 70 mV to 220 mV · CMC 28 · 10⁻⁶ · U 50 kHz to 100 kHz — 220 mV to 700 mV · CMC 13 · 10⁻⁶ · U 50 kHz to 100 kHz — 700 mV to 2,2V · CMC 11 · 10⁻⁶ · U 50 kHz to 100 kHz — 2,2 V to 7 V · CMC 13 · 10⁻⁶ · U 50 kHz to 100 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 50 kHz to 100 kHz — 22 V to 70 V · CMC 25 · 10⁻⁶ · U 50 kHz to 100 kHz — 70 V to 220 V · CMC 32 · 10⁻⁶ · U 50 kHz to 100 kHz — 220 V to 1000 V · CMC 65 · 10⁻⁶ · U 100 kHz to 300 kHz — 1 mV to 2,2 mV · CMC 0,46 · 10⁻³ · U 100 kHz to 300 kHz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 100 kHz to 300 kHz — 7 mV to 22 mV · CMC 95 · 10⁻⁶ · U 100 kHz to 300 kHz — 22 mV to 70 mV · CMC 55 · 10⁻⁶ · U 100 kHz to 300 kHz — 70 mV to 220 mV · CMC 42 · 10⁻⁶ · U 100 kHz to 300 kHz — 220 mV to 700 mV · CMC 14 · 10⁻⁶ · U 100 kHz to 300 kHz — 700 mV to 2,2 V · CMC 11 · 10⁻⁶ · U 100 kHz to 300 kHz — 2,2 V to 7 V · CMC 13 · 10⁻⁶ · U 100 kHz to 300 kHz — 7 V to 22 V · CMC 25 · 10⁻⁶ · U 100 kHz to 300 kHz — 22 V to 70 V · CMC 25 · 10⁻⁶ · U 300 kHz to 500 kHz — 1 mV to 2,2 mV · CMC 0,55 · 10⁻³ · U 300 kHz to 500 kHz — 2,2 mV to 7 mV · CMC 0,33 · 10⁻³ · U 300 kHz to 500 kHz — 7 mV to 22 mV · CMC 0,19 · 10⁻³ · U 300 kHz to 500 kHz — 22 mV to 70 mV · CMC 0,11 · 10⁻³ · U 300 kHz to 500 kHz — 70 mV to 220 mV · CMC 85 · 10⁻⁶ · U 300 kHz to 500 kHz — 220 mV to 700 mV · CMC 27 · 10⁻⁶ · U 300 kHz to 500 kHz — 700 mV to 2,2 V · CMC 22 · 10⁻⁶ · U 300 kHz to 500 kHz — 2,2 V to 7 V · CMC 30 · 10⁻⁶ · U 300 kHz to 500 kHz — 7 V to 22 V · CMC 30 · 10⁻⁶ · U 300 kHz to 500 kHz — 22 V to 70 V · CMC 40 · 10⁻⁶ · U 500 kHz to 1 MHz — 1 mV to 2,2 mV · CMC 0,60 · 10⁻³ · U 500 kHz to 1 MHz — 2,2 mV to 7 mV · CMC 0,45 · 10⁻³ · U 500 kHz to 1 MHz — 7 mV to 22 mV · CMC 0,21 · 10⁻³ · U 500 kHz to 1 MHz — 22 mV to 70 mV · CMC 0,23 · 10⁻³ · U 500 kHz to 1 MHz — 70 mV to 220 mV · CMC 0,1 · 10⁻³ · U 500 kHz to 1 MHz — 220 mV to 700 mV · CMC 40 · 10⁻⁶ · U 500 kHz to 1 MHz — 700 mV to 2,2 V · CMC 68 · 10⁻⁶ · U 500 kHz to 1 MHz — 2,2 V to 7 V · CMC 95 · 10⁻⁶ · U 500 kHz to 1 MHz — 7 V to 22 V · CMC 0,11 · 10⁻³ · U 500 kHz to 1 MHz — 22 V to 70 V · CMC 0,13 · 10⁻³ · U
AC voltage
Direct and indirect method; At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0
18 Analogue voltmeters Calibration — AC voltage
50 kHz to 100 kHz — 1 mV to 2,2 mV · CMC 0,41 · 10⁻³ · U 50 kHz to 100 kHz — 2,2 mV to 7 mV · CMC 0,2 · 10⁻³ · U 50 kHz to 100 kHz — 7 mV to 22 mV · CMC 75 · 10⁻⁶ · U 50 kHz to 100 kHz — 22 mV to 70 mV · CMC 45 · 10⁻⁶ · U 50 kHz to 100 kHz — 70 mV to 220 mV · CMC 28 · 10⁻⁶ · U 50 kHz to 100 kHz — 220 mV to 700 mV · CMC 13 · 10⁻⁶ · U 50 kHz to 100 kHz — 700 mV to 2,2V · CMC 11 · 10⁻⁶ · U 50 kHz to 100 kHz — 2,2 V to 7 V · CMC 13 · 10⁻⁶ · U 50 kHz to 100 kHz — 7 V to 22 V · CMC 11 · 10⁻⁶ · U 50 kHz to 100 kHz — 22 V to 70 V · CMC 25 · 10⁻⁶ · U 50 kHz to 100 kHz — 70 V to 220 V · CMC 32 · 10⁻⁶ · U 50 kHz to 100 kHz — 220 V to 1000 V · CMC 65 · 10⁻⁶ · U 100 kHz to 300 kHz — 1 mV to 2,2 mV · CMC 0,46 · 10⁻³ · U 100 kHz to 300 kHz — 2,2 mV to 7 mV · CMC 0,22 · 10⁻³ · U 100 kHz to 300 kHz — 7 mV to 22 mV · CMC 95 · 10⁻⁶ · U 100 kHz to 300 kHz — 22 mV to 70 mV · CMC 55 · 10⁻⁶ · U 100 kHz to 300 kHz — 70 mV to 220 mV · CMC 42 · 10⁻⁶ · U 100 kHz to 300 kHz — 220 mV to 700 mV · CMC 14 · 10⁻⁶ · U 100 kHz to 300 kHz — 700 mV to 2,2 V · CMC 11 · 10⁻⁶ · U 100 kHz to 300 kHz — 2,2 V to 7 V · CMC 13 · 10⁻⁶ · U 100 kHz to 300 kHz — 7 V to 22 V · CMC 25 · 10⁻⁶ · U 100 kHz to 300 kHz — 22 V to 70 V · CMC 25 · 10⁻⁶ · U 300 kHz to 500 kHz — 1 mV to 2,2 mV · CMC 0,55 · 10⁻³ · U 300 kHz to 500 kHz — 2,2 mV to 7 mV · CMC 0,33 · 10⁻³ · U 300 kHz to 500 kHz — 7 mV to 22 mV · CMC 0,19 · 10⁻³ · U 300 kHz to 500 kHz — 22 mV to 70 mV · CMC 0,11 · 10⁻³ · U 300 kHz to 500 kHz — 70 mV to 220 mV · CMC 85 · 10⁻⁶ · U 300 kHz to 500 kHz — 220 mV to 700 mV · CMC 27 · 10⁻⁶ · U 300 kHz to 500 kHz — 700 mV to 2,2 V · CMC 22 · 10⁻⁶ · U 300 kHz to 500 kHz — 2,2 V to 7 V · CMC 30 · 10⁻⁶ · U 300 kHz to 500 kHz — 7 V to 22 V · CMC 30 · 10⁻⁶ · U 300 kHz to 500 kHz — 22 V to 70 V · CMC 40 · 10⁻⁶ · U 500 kHz to 1 MHz — 1 mV to 2,2 mV · CMC 0,60 · 10⁻³ · U 500 kHz to 1 MHz — 2,2 mV to 7 mV · CMC 0,45 · 10⁻³ · U 500 kHz to 1 MHz — 7 mV to 22 mV · CMC 0,21 · 10⁻³ · U 500 kHz to 1 MHz — 22 mV to 70 mV · CMC 0,23 · 10⁻³ · U 500 kHz to 1 MHz — 70 mV to 220 mV · CMC 0,1 · 10⁻³ · U 500 kHz to 1 MHz — 220 mV to 700 mV · CMC 40 · 10⁻⁶ · U 500 kHz to 1 MHz — 700 mV to 2,2 V · CMC 68 · 10⁻⁶ · U 500 kHz to 1 MHz — 2,2 V to 7 V · CMC 95 · 10⁻⁶ · U 500 kHz to 1 MHz — 7 V to 22 V · CMC 0,11 · 10⁻³ · U 500 kHz to 1 MHz — 22 V to 70 V · CMC 0,13 · 10⁻³ · U
AC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP.07.01
19 Calibrators
Digital ammeters
Multimeters
Calibration — AC current
10 Hz to 40 Hz — 100 µA to 1 mA · CMC 12 · 10⁻⁵ · I 10 Hz to 40 Hz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 10 Hz to 40 Hz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 10 Hz to 40 Hz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 10 Hz to 40 Hz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I 40 Hz to 1 kHz — 100 µA to 1 mA · CMC 16 · 10⁻⁵ · I 40 Hz to 1 kHz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 40 Hz to 1 kHz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 40 Hz to 1 kHz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 40 Hz to 1 kHz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I 1 kHz to 10 kHz — 100 µA to 1 mA · CMC 60 · 10⁻⁶ · I 1 kHz to 10 kHz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 1 kHz to 10 kHz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 1 kHz to 10 kHz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 1 kHz to 10 kHz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I
AC current
Direct and indirect method; At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0
20 Analogue ammeters Calibration — AC current
10 Hz to 40 Hz — 100 µA to 1 mA · CMC 12 · 10⁻⁵ · I 10 Hz to 40 Hz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 10 Hz to 40 Hz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 10 Hz to 40 Hz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 10 Hz to 40 Hz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I 40 Hz to 1 kHz — 100 µA to 1 mA · CMC 16 · 10⁻⁵ · I 40 Hz to 1 kHz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 40 Hz to 1 kHz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 40 Hz to 1 kHz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 40 Hz to 1 kHz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I 1 kHz to 10 kHz — 100 µA to 1 mA · CMC 60 · 10⁻⁶ · I 1 kHz to 10 kHz — 1 mA to 10 mA · CMC 46 · 10⁻⁶ · I 1 kHz to 10 kHz — 10 mA to 1 A · CMC 17 · 10⁻⁶ · I 1 kHz to 10 kHz — 1 A to 10 A · CMC 32 · 10⁻⁶ · I 1 kHz to 10 kHz — 10 A to 20 A · CMC 39 · 10⁻⁶ · I
AC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP.07.01
21 Clamp meters Calibration — AC current
40 Hz to 5 kHz — 1 mA to 2,2 A · CMC 2 · 10⁻³ · I 40 Hz to 5 kHz — 2,2 A to 20 A · CMC 3 · 10⁻³ · I 40 Hz to 5 kHz — 20 A to 800 A · CMC 4 · 10⁻³ · I
AC current
Direct method; At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0
22 Calibrators
Digital ohmmeters
Multimeters
Calibration — DC resistance
1 Ω to 11 Ω · CMC 0,12 · 10⁻³· R 11 Ω to 33 Ω · CMC 33 · 10⁻⁶ · R 33 Ω to 110 Ω · CMC 29 · 10⁻⁶ · R 110 Ω to 330 Ω · CMC 28 · 10⁻⁶ · R 330 Ω to 1,1 kΩ · CMC 28 · 10⁻⁶ · R 1,1 kΩ to 3,3 kΩ · CMC 28 · 10⁻⁶ · R 3,3 kΩ to 11 kΩ · CMC 28 · 10⁻⁶ · R 11 kΩ to 33 kΩ · CMC 28 · 10⁻⁶ · R 33 kΩ to 110 kΩ · CMC 28 · 10⁻⁶ · R 110 kΩ to 330 kΩ · CMC 32 · 10⁻⁶ · R 330 kΩ to 1,1 MΩ · CMC 33 · 10⁻⁶ · R 1,1 MΩ to 3,3 MΩ · CMC 62 · 10⁻⁶ · R 3,3 MΩ to 11 MΩ · CMC 0,13 · 10⁻³ · R 11 MΩ to 33 MΩ · CMC 0,25 · 10⁻³ · R 33 MΩ to 110 MΩ · CMC 0,5 · 10⁻³ · R 110 MΩ to 330 MΩ · CMC 3 · 10⁻³ · R 330 MΩ to 1,1 GΩ · CMC 15 · 10⁻³ · R
DC resistance
Direct and indirect method; At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0
23 Analogue ohmmeters Calibration — DC resistance
1 Ω to 11 Ω · CMC 0,12 · 10⁻³· R 11 Ω to 33 Ω · CMC 33 · 10⁻⁶ · R 33 Ω to 110 Ω · CMC 29 · 10⁻⁶ · R 110 Ω to 330 Ω · CMC 28 · 10⁻⁶ · R 330 Ω to 1,1 kΩ · CMC 28 · 10⁻⁶ · R 1,1 kΩ to 3,3 kΩ · CMC 28 · 10⁻⁶ · R 3,3 kΩ to 11 kΩ · CMC 28 · 10⁻⁶ · R 11 kΩ to 33 kΩ · CMC 28 · 10⁻⁶ · R 33 kΩ to 110 kΩ · CMC 28 · 10⁻⁶ · R 110 kΩ to 330 kΩ · CMC 32 · 10⁻⁶ · R 330 kΩ to 1,1 MΩ · CMC 33 · 10⁻⁶ · R 1,1 MΩ to 3,3 MΩ · CMC 62 · 10⁻⁶ · R 3,3 MΩ to 11 MΩ · CMC 0,13 · 10⁻³ · R 11 MΩ to 33 MΩ · CMC 0,25 · 10⁻³ · R 33 MΩ to 110 MΩ · CMC 0,5 · 10⁻³ · R 110 MΩ to 330 MΩ · CMC 3 · 10⁻³ · R 330 MΩ to 1,1 GΩ · CMC 15 · 10⁻³ · R
DC resistance
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP.07.01
24 Temperature indicators (meters) for use with thermocouples Calibration — Electrical simulation of quantities
-200 °C to 1820 °C · CMC 0,15 °C
Electrical simulation of quantities
Indirect electrical method; At permanent location (S) and outside of it (P) EURAMET cg-11 v.2.0 PN-EN 60584-1:2014-04
25 Temperature indicators (meters) for use with resistance sensors Calibration — Electrical simulation of quantities
-200 °C to 850 °C · CMC 0,05 °C
Electrical simulation of quantities
Indirect electrical method; At permanent location (S) and outside of it (P) EURAMET cg-11 v.2.0 PN-EN 60751:2022
26 Anemometers Calibration — Air velocity (flow – gases)
1 m/s to 5 m/s · CMC 0,15 m/s 5 m/s to 10 m/s · CMC 0,20 m/s 10 m/s to 20 m/s · CMC 0,30 m/s 20 m/s to 25 m/s · CMC 0,50 m/s
Air velocity (flow – gases)
Internal procedure; At permanent location (S) Internal procedure PP.11.01
27 Torque wrenches Calibration — Torque
1 N∙m to 3000 N∙m · CMC 0,9 %
Torque
At permanent location (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03
28 Torque screwdrivers Calibration — Torque
1 N∙m to 10 N∙m · CMC 0,9 %
Torque
At permanent location (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03
29 Thermohygrometers
Hygrometers
Calibration — Relative humidity
temperature range 5 °C to 10 °C — 5 %rh to 98 %rh · CMC 1,2 %rh temperature range 10 °C to 40 °C — 5 %rh to 98 %rh · CMC 0,8 %rh temperature range 40 °C to 90 °C — 5 %rh to 98 %rh · CMC 1,5 %rh
Relative humidity
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure PP.14.01
30 Climatic chambers Calibration — Relative humidity
temperature range 5 °C to 90 °C — 5 %rh to 98 %rh · CMC 1,5 %rh
Relative humidity
At permanent location (S) and outside of it (P) EURAMET cg-20 v. 5.0
31 Non-automatic electronic weighing instruments Calibration — Mass (weighing instruments)
up to 500 g · CMC 2,0 · 10⁻⁴ % 500 g do 20 kg · CMC 1,1 · 10⁻³ % 20 kg do 60 kg · CMC 3,3 · 10⁻² %
Mass (weighing instruments)
At permanent location (S) and outside of it (P) EURAMET cg-18 v. 4.0
32 Barometers Calibration — Pressure
700 hPa to 1200 hPa · CMC 0,25 hPa
Pressure
Direct method; At permanent location (S) and outside of it (P) EURAMET cg-17 v.4.1
33 Electronic pressure gauges
Pressure transmitters
Calibration — Pressure
-0,1 MPa to 0 MPa · CMC 0,00003 MPa 0 MPa do 0,5 MPa · CMC 0,00004 MPa 0,5 MPa do 1 MPa · CMC 0,00013 MPa 1 MPa do 1,5 MPa · CMC 0,00017 MPa 1,5 MPa do 2 MPa · CMC 0,00027 MPa 2 MPa do 12,5 MPa · CMC 0,0032 MPa 12,5 MPa do 25 MPa · CMC 0,0040 MPa 25 MPa do 37,5 MPa · CMC 0,0047 MPa 37,5 MPa do 50 MPa · CMC 0,0060 MPa 50 MPa do 62,5 MPa · CMC 0,0070 MPa 62,5 MPa do 75 MPa · CMC 0,0080 MPa 75 MPa do 87,5 MPa · CMC 0,0090 MPa 87,5 MPa do 100 MPa · CMC 0,011 MPa
Pressure
Direct method; At permanent location (S) and outside of it (P) EURAMET cg-17 v.4.1
34 Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry)
-90 °C to 100 °C · CMC 0,05 °C 100 °C to 160 °C · CMC 0,08 °C 160 °C to 200 °C · CMC 0,15 °C 200 °C to 250 °C · CMC 0,25 °C
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure PP.19.01
35 Climatic chambers
Thermostatic chambers
Calibration — Temperature (electrical thermometry)
-80 °C to 200 °C · CMC 0,5 °C
Temperature (electrical thermometry)
At permanent location (S) and outside of it (P) EURAMET cg-20 v. 5.0
36 Steam sterilisation chambers (e.g. autoclaves) Calibration — Temperature (electrical thermometry)
0 °C to 150 °C · CMC 0,9 °C
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure PP.14.19.01
37 Pyrometers (including radiation pyrometers, thermal imaging cameras) Calibration — Temperature (radiation thermometry)
-15 °C to 50 °C · CMC 0,5 °C 50 °C to 120 °C · CMC 0,8 °C 120 °C to 300 °C · CMC 1,5 °C 300 °C to 500 °C · CMC 2,5 °C
Temperature (radiation thermometry)
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP.19.03

Reference standards (21)

EURAMET cg-11 v.2.0
EURAMET cg-15 v.3.0
EURAMET cg-17 v.4.1
EURAMET cg-18 v. 4.0
EURAMET cg-20 v. 5.0
PN-EN 60584-1:2014-04
PN-EN 60751:2022
PN-EN ISO 13385-1:2019
PN-EN ISO 3650:2000
PN-EN ISO 6789-1:2017-03
PN-EN ISO 6789-2:2017-03
PP.03.01
PP.03.02
PP.03.03
PP.03.04
PP.07.01
PP.11.01
PP.14.01
PP.14.19.01
PP.19.01
PP.19.03