{"lab":{"_id":"6afa3b958989a133b76445bc","accr_number":"AP 176","country":"PL","imported_at":"2026-11-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"Aleja Krakowska 2A, 02-284 Warszawa","approver":"Tadeusz Matras","categories":["metrology"],"certificate_date":"02.08.2023","city":"Warszawa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.","cycle_from":"06.11.2025","cycle_to":"06.12.2029","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"3.01","pl":"pH","en":"pH","de":"pH","zh":"pH 值","cs":"pH"},{"codes":"3.02","pl":"przewodność elektryczna właściwa (konduktometria)","en":"electrolytic conductivity (conductometry)","de":"spezifische elektrische Leitfähigkeit (Konduktometrie)","zh":"电导率（电导测量）","cs":"měrná elektrická vodivost (konduktometrie)"},{"codes":"3.03","pl":"ułamek objętościowy (analiza gazów)","en":"volume fraction (gas analysis)","de":"Volumenanteil (Gasanalyse)","zh":"体积分数（气体分析）","cs":"objemový zlomek (analýza plynů)"},{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"7.01","pl":"napięcie DC","en":"DC voltage","de":"Gleichspannung","zh":"直流电压","cs":"stejnosměrné napětí (DC)"},{"codes":"7.02","pl":"prąd DC","en":"DC current","de":"DC-Strom","zh":"直流电流","cs":"proud DC"},{"codes":"7.03","pl":"napięcie AC","en":"AC voltage","de":"AC-Spannung","zh":"交流电压","cs":"napětí AC"},{"codes":"7.04","pl":"prąd AC","en":"AC current","de":"AC-Strom","zh":"交流电流","cs":"proud AC"},{"codes":"7.05","pl":"rezystancja DC","en":"DC resistance","de":"DC-Widerstand","zh":"直流电阻","cs":"odpor DC"},{"codes":"7.15","pl":"elektryczna symulacja wielkości","en":"electrical simulation of quantities","de":"elektrische Simulation von Größen","zh":"量值的电模拟","cs":"elektrická simulace veličin"},{"codes":"11.02","pl":"prędkość powietrza (przepływ - gazy)","en":"air velocity (flow - gases)","de":"Luftgeschwindigkeit (Durchfluss - Gase)","zh":"空气流速（流量 - 气体）","cs":"rychlost vzduchu (průtok - plyny)"},{"codes":"12.02","pl":"moment siły","en":"torque","de":"Drehmoment","zh":"力矩","cs":"moment síly"},{"codes":"14.02","pl":"wilgotność względna","en":"relative humidity","de":"relative Feuchte","zh":"相对湿度","cs":"relativní vlhkost"},{"codes":"15.01","pl":"masa (wagi)","en":"mass (weighing instruments)","de":"Masse (Waagen)","zh":"质量（衡器）","cs":"hmotnost (váhy)"},{"codes":"17.01","pl":"ciśnienie","en":"pressure","de":"Druck","zh":"压力","cs":"tlak"},{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"teplota (elektrická termometrie)"},{"codes":"19.03","pl":"temperatura (termometria radiacyjna)","en":"temperature (radiation thermometry)","de":"Temperatur (Strahlungsthermometrie)","zh":"温度（辐射测温）","cs":"teplota (radiační termometrie)"}],"has_en":true,"has_zh":true,"issue":{"no":"19","date":"26.10.2026"},"issue_date":"26.10.2026","issue_number":"19","lab_division":null,"lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[20.9314223,52.1631855]},"map_coord":[52.1631855,20.9314223],"map_geo":"nominatim-street","methods_count":37,"name":"Testo Industrial Services sp. z o.o.","parse_date":"2026-11-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-15T12:00:00.000Z","pdf_files":["AP_176.pdf"],"scope_notes":[{"pl":"Wartość niepewność pomiaru dla CMC wyrażona w postaci równania Q[a; b] oznacza pierwiastek kwadratowy wyrazów w nawiasach: Q[a; b] = (a² + b²)^1/2.","en":"A CMC uncertainty value expressed as Q[a; b] means the square root of the terms in brackets: Q[a; b] = (a² + b²)^1/2."}],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: pH, przewodność elektryczna właściwa (konduktometria), ułamek objętościowy (analiza gazów), długość, napięcie DC, prąd DC, napięcie AC, prąd AC, rezystancja DC, elektryczna symulacja wielkości, prędkość powietrza (przepływ - gazy), moment siły, wilgotność względna, masa (wagi), ciśnienie, temperatura (termometria elektryczna), temperatura (termometria radiacyjna). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"testo industrial services sp. z o.o. aleja krakowska 2a, 02-284 warszawa laboratorium wzorcujące. wielkości mierzone: ph, przewodność elektryczna właściwa (konduktometria), ułamek objętościowy (analiza gazów), długość, napięcie dc, prąd dc, napięcie ac, prąd ac, rezystancja dc, elektryczna symulacja wielkości, prędkość powietrza (przepływ - gazy), moment siły, wilgotność względna, masa (wagi), ciśnienie, temperatura (termometria elektryczna), temperatura (termometria radiacyjna). w stałej lokalizacji (s) i/lub poza nią (p). ap 176 ap176 laboratorium wzorcujące wzorcowanie kalibracja ph electrolytic conductivity (conductometry) volume fraction (gas analysis) length dc voltage dc current ac voltage ac current dc resistance electrical simulation of quantities air velocity (flow - gases) torque relative humidity mass (weighing instruments) pressure temperature (electrical thermometry) temperature (radiation thermometry) testo industrial services sp. z o.o. aleja krakowska 2a, 02-284 warszawa laboratorium wzorcujace. wielkosci mierzone: ph, przewodnosc elektryczna wlasciwa (konduktometria), ulamek objetosciowy (analiza gazow), dlugosc, napiecie dc, prad dc, napiecie ac, prad ac, rezystancja dc, elektryczna symulacja wielkosci, predkosc powietrza (przeplyw - gazy), moment sily, wilgotnosc wzgledna, masa (wagi), cisnienie, temperatura (termometria elektryczna), temperatura (termometria radiacyjna). w stalej lokalizacji (s) i/lub poza nia (p). ap 176 ap176 laboratorium wzorcujace wzorcowanie kalibracja ph electrolytic conductivity (conductometry) volume fraction (gas analysis) length dc voltage dc current ac voltage ac current dc resistance electrical simulation of quantities air velocity (flow - gases) torque relative humidity mass (weighing instruments) pressure temperature (electrical thermometry) temperature (radiation thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20176,podmiot.html","source_pdf_sha256":"5587b5652f76f4ba6cbc45ac818aee87f73073ee510e1520a470b2dacf185e80","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/15/cdbee5a4dd8af14b7f0fe52ab66765ca/AP%20176.pdf","status":"active","updated_at":"2026-11-15T12:00:00.000Z","valid_from":"07-12-2017","valid_until":"06-12-2029","website":"www.testotis.pl","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"pelny_cs":true},"methods":[{"_id":"7b2d880db0d4642ea63f14f2","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Pehametry","test_object_en":"pH meters","methodology":"Wzorcowanie — pH","methodology_en":"Calibration — pH","parameters":[{"name":"- pH","range":"0 do 14","cmc":"0,002"},{"name":"- napięcie stałe","range":"-2000 mV do 2000 mV","cmc":"0,2 mV"}],"parameters_en":[{"name":"- pH","range":"0 to 14","cmc":"0,002"},{"name":"- DC voltage","range":"-2000 mV to 2000 mV","cmc":"0,2 mV"}],"technique":"Procedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Electrical method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda elektryczna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Electrical method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — pH\nZakres:\n- pH 0 do 14 CMC 0,002\n- napięcie stałe -2000 mV do 2000 mV CMC 0,2 mV\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.03.03","norm_bases":["PP.03.03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"pH","regulatory_area_en":"pH","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Pehametry Wzorcowanie — pH\nZakres:\n- pH 0 do 14 CMC 0,002\n- napięcie stałe -2000 mV do 2000 mV CMC 0,2 mV\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.03.03 Pehametry Wzorcowanie — pH\nZakres:\n- pH 0 do 14 CMC 0,002\n- napiecie stale -2000 mV do 2000 mV CMC 0,2 mV\nProcedura wewnetrzna; Metoda elektryczna; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.03.03","search_en":"pH meters Calibration — pH Internal procedure; Electrical method; At permanent location (S) and outside of it (P) pH Internal procedure Electrical method At permanent location (S) and outside of it (P) - pH - DC voltage Internal procedure PP.03.03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.03.03","methodology_de":"Kalibrierung — pH","parameters_de":[{"name":"- pH","range":"0 to 14","cmc":"0,002"},{"name":"- Gleichspannung","range":"-2000 mV to 2000 mV","cmc":"0,2 mV"}],"reference_de":"Internes Verfahren PP.03.03","regulatory_area_de":"pH","search_de":"pH-Meter Kalibrierung — pH Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S) und außerhalb (P) pH Internes Verfahren Elektrisches Verfahren Am festen Standort (S) und außerhalb (P) - pH - Gleichspannung Internes Verfahren PP.03.03","technique_de":"Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Elektrisches Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"pH-Meter","methodology_zh":"校准 — pH","parameters_zh":[{"name":"- pH","range":"0 to 14","cmc":"0,002"},{"name":"- 直流电压","range":"-2000 mV to 2000 mV","cmc":"0,2 mV"}],"reference_zh":"内部程序 PP.03.03","regulatory_area_zh":"pH 值","search_zh":"pH 计 校准 — pH 内部程序；电学法；在固定地点 (S) 及固定地点以外 (P) pH 值 内部程序 电学法 在固定地点 (S) 及固定地点以外 (P) - pH - 直流电压 内部程序 PP.03.03","technique_zh":"内部程序；电学法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","电学法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"pH 计","methodology_cs":"Kalibrace — pH","parameters_cs":[{"name":"- pH","range":"0 to 14","cmc":"0,002"},{"name":"- stejnosměrné napětí","range":"-2000 mV to 2000 mV","cmc":"0,2 mV"}],"reference_cs":"Vnitřní postup PP.03.03","regulatory_area_cs":"pH","search_cs":"pH metry Kalibrace — pH Vnitřní postup; Elektrická metoda; V trvalé lokalitě (S) i mimo ni (P) pH Vnitřní postup Elektrická metoda V trvalé lokalitě (S) i mimo ni (P) - pH - stejnosměrné napětí Vnitřní postup PP.03.03","technique_cs":"Vnitřní postup; Elektrická metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Elektrická metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"pH metry"},{"_id":"2584fbd0f4b5adc444c9b591","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Pehametry","test_object_en":"pH meters","methodology":"Wzorcowanie — pH","methodology_en":"Calibration — pH","parameters":[{"name":"- pH","range":"1 do 13","cmc":"0,02"}],"parameters_en":[{"name":"- pH","range":"1 to 13","cmc":"0,02"}],"technique":"Procedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Method using reference materials; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda z zastosowaniem materiałów odniesienia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Method using reference materials","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — pH\n- pH 1 do 13 CMC 0,02\nProcedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.03.03","norm_bases":["PP.03.03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"pH","regulatory_area_en":"pH","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Pehametry Wzorcowanie — pH\n- pH 1 do 13 CMC 0,02\nProcedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.03.03 Pehametry Wzorcowanie — pH\n- pH 1 do 13 CMC 0,02\nProcedura wewnetrzna; Metoda z zastosowaniem materialow odniesienia; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.03.03","search_en":"pH meters Calibration — pH Internal procedure; Method using reference materials; At permanent location (S) and outside of it (P) pH Internal procedure Method using reference materials At permanent location (S) and outside of it (P) - pH Internal procedure PP.03.03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.03.03","methodology_de":"Kalibrierung — pH","parameters_de":[{"name":"- pH","range":"1 to 13","cmc":"0,02"}],"reference_de":"Internes Verfahren PP.03.03","regulatory_area_de":"pH","search_de":"pH-Meter Kalibrierung — pH Internes Verfahren; Verfahren mit Referenzmaterialien; Am festen Standort (S) und außerhalb (P) pH Internes Verfahren Verfahren mit Referenzmaterialien Am festen Standort (S) und außerhalb (P) - pH Internes Verfahren PP.03.03","technique_de":"Internes Verfahren; Verfahren mit Referenzmaterialien; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Verfahren mit Referenzmaterialien","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"pH-Meter","methodology_zh":"校准 — pH","parameters_zh":[{"name":"- pH","range":"1 to 13","cmc":"0,02"}],"reference_zh":"内部程序 PP.03.03","regulatory_area_zh":"pH 值","search_zh":"pH 计 校准 — pH 内部程序；使用参考物质的方法；在固定地点 (S) 及固定地点以外 (P) pH 值 内部程序 使用参考物质的方法 在固定地点 (S) 及固定地点以外 (P) - pH 内部程序 PP.03.03","technique_zh":"内部程序；使用参考物质的方法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","使用参考物质的方法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"pH 计","methodology_cs":"Kalibrace — pH","parameters_cs":[{"name":"- pH","range":"1 to 13","cmc":"0,02"}],"reference_cs":"Vnitřní postup PP.03.03","regulatory_area_cs":"pH","search_cs":"pH metry Kalibrace — pH Vnitřní postup; Metoda s použitím referenčních materiálů; V trvalé lokalitě (S) i mimo ni (P) pH Vnitřní postup Metoda s použitím referenčních materiálů V trvalé lokalitě (S) i mimo ni (P) - pH Vnitřní postup PP.03.03","technique_cs":"Vnitřní postup; Metoda s použitím referenčních materiálů; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Metoda s použitím referenčních materiálů","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"pH metry"},{"_id":"3904e69388c761f525af6a97","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Konduktometry","test_object_en":"Conductivity meters","methodology":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)","methodology_en":"Calibration — Electrolytic conductivity (conductometry)","parameters":[{"name":"","range":"0,15 mS/cm do 115 mS/cm","cmc":"0,5 %"}],"parameters_en":[{"name":"","range":"0,15 mS/cm to 115 mS/cm","cmc":"0,5 %"}],"technique":"Procedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Method using reference materials; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda z zastosowaniem materiałów odniesienia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Method using reference materials","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\n0,15 mS/cm do 115 mS/cm CMC 0,5 %\nProcedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.03.04","norm_bases":["PP.03.04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Przewodność elektryczna właściwa (konduktometria)","regulatory_area_en":"Electrolytic conductivity (conductometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Konduktometry Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\n0,15 mS/cm do 115 mS/cm CMC 0,5 %\nProcedura wewnętrzna; Metoda z zastosowaniem materiałów odniesienia; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.03.04 Konduktometry Wzorcowanie — Przewodnosc elektryczna wlasciwa (konduktometria)\n0,15 mS/cm do 115 mS/cm CMC 0,5 %\nProcedura wewnetrzna; Metoda z zastosowaniem materialow odniesienia; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.03.04","search_en":"Conductivity meters Calibration — Electrolytic conductivity (conductometry) Internal procedure; Method using reference materials; At permanent location (S) and outside of it (P) Electrolytic conductivity (conductometry) Internal procedure Method using reference materials At permanent location (S) and outside of it (P) Internal procedure PP.03.04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.03.04","methodology_de":"Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie)","parameters_de":[{"name":"","range":"0,15 mS/cm to 115 mS/cm","cmc":"0,5 %"}],"reference_de":"Internes Verfahren PP.03.04","regulatory_area_de":"Spezifische elektrische Leitfähigkeit (Konduktometrie)","search_de":"Leitfähigkeitsmessgeräte Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren; Verfahren mit Referenzmaterialien; Am festen Standort (S) und außerhalb (P) Spezifische elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren Verfahren mit Referenzmaterialien Am festen Standort (S) und außerhalb (P) Internes Verfahren PP.03.04","technique_de":"Internes Verfahren; Verfahren mit Referenzmaterialien; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Verfahren mit Referenzmaterialien","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Leitfähigkeitsmessgeräte","methodology_zh":"校准 — 电导率（电导法）","parameters_zh":[{"name":"","range":"0,15 mS/cm to 115 mS/cm","cmc":"0,5 %"}],"reference_zh":"内部程序 PP.03.04","regulatory_area_zh":"电导率（电导法）","search_zh":"电导率仪 校准 — 电导率（电导法） 内部程序；使用参考物质的方法；在固定地点 (S) 及固定地点以外 (P) 电导率（电导法） 内部程序 使用参考物质的方法 在固定地点 (S) 及固定地点以外 (P) 内部程序 PP.03.04","technique_zh":"内部程序；使用参考物质的方法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","使用参考物质的方法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电导率仪","methodology_cs":"Kalibrace — Měrná elektrická vodivost (konduktometrie)","parameters_cs":[{"name":"","range":"0,15 mS/cm to 115 mS/cm","cmc":"0,5 %"}],"reference_cs":"Vnitřní postup PP.03.04","regulatory_area_cs":"Měrná elektrická vodivost (konduktometrie)","search_cs":"Konduktometry Kalibrace — Měrná elektrická vodivost (konduktometrie) Vnitřní postup; Metoda s použitím referenčních materiálů; V trvalé lokalitě (S) i mimo ni (P) Měrná elektrická vodivost (konduktometrie) Vnitřní postup Metoda s použitím referenčních materiálů V trvalé lokalitě (S) i mimo ni (P) Vnitřní postup PP.03.04","technique_cs":"Vnitřní postup; Metoda s použitím referenčních materiálů; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Metoda s použitím referenčních materiálů","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Konduktometry"},{"_id":"3a5e483ea33b4aaf21d3606a","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Konduktometry","test_object_en":"Conductivity meters","methodology":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)","methodology_en":"Calibration — Electrolytic conductivity (conductometry)","parameters":[{"name":"","range":"0,2 µS/cm do 199,99 µS/cm","cmc":"0,01 %"},{"name":"","range":"0,2 mS/cm do 1999,99 mS/cm","cmc":"0,01 %"}],"parameters_en":[{"name":"","range":"0,2 µS/cm to 199,99 µS/cm","cmc":"0,01 %"},{"name":"","range":"0,2 mS/cm to 1999,99 mS/cm","cmc":"0,01 %"}],"technique":"Procedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Electrical method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda elektryczna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Electrical method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\nZakres:\n0,2 µS/cm do 199,99 µS/cm CMC 0,01 %\n0,2 mS/cm do 1999,99 mS/cm CMC 0,01 %\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.03.04","norm_bases":["PP.03.04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Przewodność elektryczna właściwa (konduktometria)","regulatory_area_en":"Electrolytic conductivity (conductometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Konduktometry Wzorcowanie — Przewodność elektryczna właściwa (konduktometria)\nZakres:\n0,2 µS/cm do 199,99 µS/cm CMC 0,01 %\n0,2 mS/cm do 1999,99 mS/cm CMC 0,01 %\nProcedura wewnętrzna; Metoda elektryczna; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.03.04 Konduktometry Wzorcowanie — Przewodnosc elektryczna wlasciwa (konduktometria)\nZakres:\n0,2 µS/cm do 199,99 µS/cm CMC 0,01 %\n0,2 mS/cm do 1999,99 mS/cm CMC 0,01 %\nProcedura wewnetrzna; Metoda elektryczna; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.03.04","search_en":"Conductivity meters Calibration — Electrolytic conductivity (conductometry) Internal procedure; Electrical method; At permanent location (S) and outside of it (P) Electrolytic conductivity (conductometry) Internal procedure Electrical method At permanent location (S) and outside of it (P) Internal procedure PP.03.04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.03.04","methodology_de":"Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie)","parameters_de":[{"name":"","range":"0,2 µS/cm to 199,99 µS/cm","cmc":"0,01 %"},{"name":"","range":"0,2 mS/cm to 1999,99 mS/cm","cmc":"0,01 %"}],"reference_de":"Internes Verfahren PP.03.04","regulatory_area_de":"Spezifische elektrische Leitfähigkeit (Konduktometrie)","search_de":"Leitfähigkeitsmessgeräte Kalibrierung — Elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S) und außerhalb (P) Spezifische elektrische Leitfähigkeit (Konduktometrie) Internes Verfahren Elektrisches Verfahren Am festen Standort (S) und außerhalb (P) Internes Verfahren PP.03.04","technique_de":"Internes Verfahren; Elektrisches Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Elektrisches Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Leitfähigkeitsmessgeräte","methodology_zh":"校准 — 电导率（电导法）","parameters_zh":[{"name":"","range":"0,2 µS/cm to 199,99 µS/cm","cmc":"0,01 %"},{"name":"","range":"0,2 mS/cm to 1999,99 mS/cm","cmc":"0,01 %"}],"reference_zh":"内部程序 PP.03.04","regulatory_area_zh":"电导率（电导法）","search_zh":"电导率仪 校准 — 电导率（电导法） 内部程序；电学法；在固定地点 (S) 及固定地点以外 (P) 电导率（电导法） 内部程序 电学法 在固定地点 (S) 及固定地点以外 (P) 内部程序 PP.03.04","technique_zh":"内部程序；电学法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","电学法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电导率仪","methodology_cs":"Kalibrace — Měrná elektrická vodivost (konduktometrie)","parameters_cs":[{"name":"","range":"0,2 µS/cm to 199,99 µS/cm","cmc":"0,01 %"},{"name":"","range":"0,2 mS/cm to 1999,99 mS/cm","cmc":"0,01 %"}],"reference_cs":"Vnitřní postup PP.03.04","regulatory_area_cs":"Měrná elektrická vodivost (konduktometrie)","search_cs":"Konduktometry Kalibrace — Měrná elektrická vodivost (konduktometrie) Vnitřní postup; Elektrická metoda; V trvalé lokalitě (S) i mimo ni (P) Měrná elektrická vodivost (konduktometrie) Vnitřní postup Elektrická metoda V trvalé lokalitě (S) i mimo ni (P) Vnitřní postup PP.03.04","technique_cs":"Vnitřní postup; Elektrická metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Elektrická metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Konduktometry"},{"_id":"b7603c43e4629514c0d8667b","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Analizatory spalin kominowych","test_object_en":"Flue gas analysers","methodology":"Wzorcowanie — Ułamek objętościowy (analiza gazów)","methodology_en":"Calibration — Volume fraction (gas analysis)","parameters":[{"name":"NO","range":"0,1 µmol/mol do 10 µmol/mol","cmc":"5%"},{"name":"NO","range":"10 µmol/mol do 1000 µmol/mol","cmc":"5%"},{"name":"NO₂","range":"0,1 µmol/mol do 10 µmol/mol","cmc":"6%"},{"name":"NO₂","range":"10 µmol/mol do 1000 µmol/mol","cmc":"6%"},{"name":"CO","range":"0,1 µmol/mol do 10 µmol/mol","cmc":"10 %"},{"name":"CO","range":"10 µmol/mol do 1000 µmol/mol","cmc":"10 %"},{"name":"CO₂","range":"3 µmol/mol do 500 mmol/mol","cmc":"3%"},{"name":"SO₂","range":"0,1 µmol/mol do 10 µmol/mol","cmc":"6%"},{"name":"SO₂","range":"10 µmol/mol do 1000 µmol/mol","cmc":"6%"},{"name":"O₂","range":"5 µmol/mol do 220 mmol/mol","cmc":"3%"}],"parameters_en":[{"name":"NO","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"5%"},{"name":"NO","range":"10 µmol/mol to 1000 µmol/mol","cmc":"5%"},{"name":"NO₂","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"6%"},{"name":"NO₂","range":"10 µmol/mol to 1000 µmol/mol","cmc":"6%"},{"name":"CO","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"10 %"},{"name":"CO","range":"10 µmol/mol to 1000 µmol/mol","cmc":"10 %"},{"name":"CO₂","range":"3 µmol/mol to 500 mmol/mol","cmc":"3%"},{"name":"SO₂","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"6%"},{"name":"SO₂","range":"10 µmol/mol to 1000 µmol/mol","cmc":"6%"},{"name":"O₂","range":"5 µmol/mol to 220 mmol/mol","cmc":"3%"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ułamek objętościowy (analiza gazów)\nZakres:\nNO 0,1 µmol/mol do 10 µmol/mol CMC 5%\nNO 10 µmol/mol do 1000 µmol/mol CMC 5%\nNO₂ 0,1 µmol/mol do 10 µmol/mol CMC 6%\nNO₂ 10 µmol/mol do 1000 µmol/mol CMC 6%\nCO 0,1 µmol/mol do 10 µmol/mol CMC 10 %\nCO 10 µmol/mol do 1000 µmol/mol CMC 10 %\nCO₂ 3 µmol/mol do 500 mmol/mol CMC 3%\nSO₂ 0,1 µmol/mol do 10 µmol/mol CMC 6%\nSO₂ 10 µmol/mol do 1000 µmol/mol CMC 6%\nO₂ 5 µmol/mol do 220 mmol/mol CMC 3%\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP.03.01","norm_bases":["PP.03.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ułamek objętościowy (analiza gazów)","regulatory_area_en":"Volume fraction (gas analysis)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Analizatory spalin kominowych Wzorcowanie — Ułamek objętościowy (analiza gazów)\nZakres:\nNO 0,1 µmol/mol do 10 µmol/mol CMC 5%\nNO 10 µmol/mol do 1000 µmol/mol CMC 5%\nNO₂ 0,1 µmol/mol do 10 µmol/mol CMC 6%\nNO₂ 10 µmol/mol do 1000 µmol/mol CMC 6%\nCO 0,1 µmol/mol do 10 µmol/mol CMC 10 %\nCO 10 µmol/mol do 1000 µmol/mol CMC 10 %\nCO₂ 3 µmol/mol do 500 mmol/mol CMC 3%\nSO₂ 0,1 µmol/mol do 10 µmol/mol CMC 6%\nSO₂ 10 µmol/mol do 1000 µmol/mol CMC 6%\nO₂ 5 µmol/mol do 220 mmol/mol CMC 3%\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP.03.01 Analizatory spalin kominowych Wzorcowanie — Ulamek objetosciowy (analiza gazow)\nZakres:\nNO 0,1 µmol/mol do 10 µmol/mol CMC 5%\nNO 10 µmol/mol do 1000 µmol/mol CMC 5%\nNO₂ 0,1 µmol/mol do 10 µmol/mol CMC 6%\nNO₂ 10 µmol/mol do 1000 µmol/mol CMC 6%\nCO 0,1 µmol/mol do 10 µmol/mol CMC 10 %\nCO 10 µmol/mol do 1000 µmol/mol CMC 10 %\nCO₂ 3 µmol/mol do 500 mmol/mol CMC 3%\nSO₂ 0,1 µmol/mol do 10 µmol/mol CMC 6%\nSO₂ 10 µmol/mol do 1000 µmol/mol CMC 6%\nO₂ 5 µmol/mol do 220 mmol/mol CMC 3%\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP.03.01","search_en":"Flue gas analysers Calibration — Volume fraction (gas analysis) Internal procedure; At permanent location (S) Volume fraction (gas analysis) Internal procedure At permanent location (S) NO NO NO₂ NO₂ CO CO CO₂ SO₂ SO₂ O₂ Internal procedure PP.03.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.03.01","methodology_de":"Kalibrierung — Volumenanteil (Gasanalyse)","parameters_de":[{"name":"NO","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"5%"},{"name":"NO","range":"10 µmol/mol to 1000 µmol/mol","cmc":"5%"},{"name":"NO₂","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"6%"},{"name":"NO₂","range":"10 µmol/mol to 1000 µmol/mol","cmc":"6%"},{"name":"CO","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"10 %"},{"name":"CO","range":"10 µmol/mol to 1000 µmol/mol","cmc":"10 %"},{"name":"CO₂","range":"3 µmol/mol to 500 mmol/mol","cmc":"3%"},{"name":"SO₂","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"6%"},{"name":"SO₂","range":"10 µmol/mol to 1000 µmol/mol","cmc":"6%"},{"name":"O₂","range":"5 µmol/mol to 220 mmol/mol","cmc":"3%"}],"reference_de":"Internes Verfahren PP.03.01","regulatory_area_de":"Volumenanteil (Gasanalyse)","search_de":"Rauchgasanalysatoren Kalibrierung — Volumenanteil (Gasanalyse) Internes Verfahren; Am festen Standort (S) Volumenanteil (Gasanalyse) Internes Verfahren Am festen Standort (S) NO NO NO₂ NO₂ CO CO CO₂ SO₂ SO₂ O₂ Internes Verfahren PP.03.01","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Rauchgasanalysatoren","methodology_zh":"校准 — 体积分数（气体分析）","parameters_zh":[{"name":"NO","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"5%"},{"name":"NO","range":"10 µmol/mol to 1000 µmol/mol","cmc":"5%"},{"name":"NO₂","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"6%"},{"name":"NO₂","range":"10 µmol/mol to 1000 µmol/mol","cmc":"6%"},{"name":"CO","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"10 %"},{"name":"CO","range":"10 µmol/mol to 1000 µmol/mol","cmc":"10 %"},{"name":"CO₂","range":"3 µmol/mol to 500 mmol/mol","cmc":"3%"},{"name":"SO₂","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"6%"},{"name":"SO₂","range":"10 µmol/mol to 1000 µmol/mol","cmc":"6%"},{"name":"O₂","range":"5 µmol/mol to 220 mmol/mol","cmc":"3%"}],"reference_zh":"内部程序 PP.03.01","regulatory_area_zh":"体积分数（气体分析）","search_zh":"烟道气分析仪 校准 — 体积分数（气体分析） 内部程序；在固定地点 (S) 体积分数（气体分析） 内部程序 在固定地点 (S) NO NO NO₂ NO₂ CO CO CO₂ SO₂ SO₂ O₂ 内部程序 PP.03.01","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"烟道气分析仪","methodology_cs":"Kalibrace — Objemový zlomek (analýza plynů)","parameters_cs":[{"name":"NO","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"5%"},{"name":"NO","range":"10 µmol/mol to 1000 µmol/mol","cmc":"5%"},{"name":"NO₂","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"6%"},{"name":"NO₂","range":"10 µmol/mol to 1000 µmol/mol","cmc":"6%"},{"name":"CO","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"10 %"},{"name":"CO","range":"10 µmol/mol to 1000 µmol/mol","cmc":"10 %"},{"name":"CO₂","range":"3 µmol/mol to 500 mmol/mol","cmc":"3%"},{"name":"SO₂","range":"0,1 µmol/mol to 10 µmol/mol","cmc":"6%"},{"name":"SO₂","range":"10 µmol/mol to 1000 µmol/mol","cmc":"6%"},{"name":"O₂","range":"5 µmol/mol to 220 mmol/mol","cmc":"3%"}],"reference_cs":"Vnitřní postup PP.03.01","regulatory_area_cs":"Objemový zlomek (analýza plynů)","search_cs":"Analyzátory kouřových plynů Kalibrace — Objemový zlomek (analýza plynů) Vnitřní postup; Ve stálé lokalitě (S) Objemový zlomek (analýza plynů) Vnitřní postup Ve stálé lokalitě (S) NO NO NO₂ NO₂ CO CO CO₂ SO₂ SO₂ O₂ Vnitřní postup PP.03.01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analyzátory kouřových plynů"},{"_id":"ab3786a1d24ecbb56235fdf7","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Mierniki stężenia gazów\nTlenomierze","test_object_en":"Gas concentration meters\nOxygen meters","methodology":"Wzorcowanie — Ułamek objętościowy (analiza gazów)","methodology_en":"Calibration — Volume fraction (gas analysis)","parameters":[{"name":"O₂","range":"0 % do 10 %","cmc":"0,1 %"},{"name":"O₂","range":"10 % do 20 %","cmc":"0,2 %"},{"name":"O₂","range":"20 % do 30 %","cmc":"0,3 %"},{"name":"O₂","range":"30 % do 50 %","cmc":"0,5 %"},{"name":"O₂","range":"50 % do 80 %","cmc":"0,8 %"},{"name":"O₂","range":"80 % do 100 %","cmc":"1,1 %"}],"parameters_en":[{"name":"O₂","range":"0 % to 10 %","cmc":"0,1 %"},{"name":"O₂","range":"10 % to 20 %","cmc":"0,2 %"},{"name":"O₂","range":"20 % to 30 %","cmc":"0,3 %"},{"name":"O₂","range":"30 % to 50 %","cmc":"0,5 %"},{"name":"O₂","range":"50 % to 80 %","cmc":"0,8 %"},{"name":"O₂","range":"80 % to 100 %","cmc":"1,1 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ułamek objętościowy (analiza gazów)\nZakres:\nO₂ 0 % do 10 % CMC 0,1 %\nO₂ 10 % do 20 % CMC 0,2 %\nO₂ 20 % do 30 % CMC 0,3 %\nO₂ 30 % do 50 % CMC 0,5 %\nO₂ 50 % do 80 % CMC 0,8 %\nO₂ 80 % do 100 % CMC 1,1 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP.03.02","norm_bases":["PP.03.02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ułamek objętościowy (analiza gazów)","regulatory_area_en":"Volume fraction (gas analysis)","outside_premises":false,"location_of_activity":"S","note":"Wskazanie odniesione do stężenia O₂ w powietrzu (%)","note_en":"Indication relative to the O₂ concentration in air (%)","search_text":"Mierniki stężenia gazów\nTlenomierze Wzorcowanie — Ułamek objętościowy (analiza gazów)\nZakres:\nO₂ 0 % do 10 % CMC 0,1 %\nO₂ 10 % do 20 % CMC 0,2 %\nO₂ 20 % do 30 % CMC 0,3 %\nO₂ 30 % do 50 % CMC 0,5 %\nO₂ 50 % do 80 % CMC 0,8 %\nO₂ 80 % do 100 % CMC 1,1 %\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP.03.02 Mierniki stezenia gazow\nTlenomierze Wzorcowanie — Ulamek objetosciowy (analiza gazow)\nZakres:\nO₂ 0 % do 10 % CMC 0,1 %\nO₂ 10 % do 20 % CMC 0,2 %\nO₂ 20 % do 30 % CMC 0,3 %\nO₂ 30 % do 50 % CMC 0,5 %\nO₂ 50 % do 80 % CMC 0,8 %\nO₂ 80 % do 100 % CMC 1,1 %\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP.03.02","search_en":"Gas concentration meters Oxygen meters Calibration — Volume fraction (gas analysis) Internal procedure; At permanent location (S) Volume fraction (gas analysis) Internal procedure At permanent location (S) O₂ O₂ O₂ O₂ O₂ O₂ Internal procedure PP.03.02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.03.02","methodology_de":"Kalibrierung — Volumenanteil (Gasanalyse)","parameters_de":[{"name":"O₂","range":"0 % to 10 %","cmc":"0,1 %"},{"name":"O₂","range":"10 % to 20 %","cmc":"0,2 %"},{"name":"O₂","range":"20 % to 30 %","cmc":"0,3 %"},{"name":"O₂","range":"30 % to 50 %","cmc":"0,5 %"},{"name":"O₂","range":"50 % to 80 %","cmc":"0,8 %"},{"name":"O₂","range":"80 % to 100 %","cmc":"1,1 %"}],"reference_de":"Internes Verfahren PP.03.02","regulatory_area_de":"Volumenanteil (Gasanalyse)","search_de":"Gaskonzentrationsmessgeräte Sauerstoffmessgeräte Kalibrierung — Volumenanteil (Gasanalyse) Internes Verfahren; Am festen Standort (S) Volumenanteil (Gasanalyse) Internes Verfahren Am festen Standort (S) O₂ O₂ O₂ O₂ O₂ O₂ Internes Verfahren PP.03.02","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Gaskonzentrationsmessgeräte\nSauerstoffmessgeräte","methodology_zh":"校准 — 体积分数（气体分析）","parameters_zh":[{"name":"O₂","range":"0 % to 10 %","cmc":"0,1 %"},{"name":"O₂","range":"10 % to 20 %","cmc":"0,2 %"},{"name":"O₂","range":"20 % to 30 %","cmc":"0,3 %"},{"name":"O₂","range":"30 % to 50 %","cmc":"0,5 %"},{"name":"O₂","range":"50 % to 80 %","cmc":"0,8 %"},{"name":"O₂","range":"80 % to 100 %","cmc":"1,1 %"}],"reference_zh":"内部程序 PP.03.02","regulatory_area_zh":"体积分数（气体分析）","search_zh":"气体浓度测量仪 测氧仪 校准 — 体积分数（气体分析） 内部程序；在固定地点 (S) 体积分数（气体分析） 内部程序 在固定地点 (S) O₂ O₂ O₂ O₂ O₂ O₂ 内部程序 PP.03.02","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"气体浓度测量仪\n测氧仪","methodology_cs":"Kalibrace — Objemový zlomek (analýza plynů)","parameters_cs":[{"name":"O₂","range":"0 % to 10 %","cmc":"0,1 %"},{"name":"O₂","range":"10 % to 20 %","cmc":"0,2 %"},{"name":"O₂","range":"20 % to 30 %","cmc":"0,3 %"},{"name":"O₂","range":"30 % to 50 %","cmc":"0,5 %"},{"name":"O₂","range":"50 % to 80 %","cmc":"0,8 %"},{"name":"O₂","range":"80 % to 100 %","cmc":"1,1 %"}],"reference_cs":"Vnitřní postup PP.03.02","regulatory_area_cs":"Objemový zlomek (analýza plynů)","search_cs":"Měřiče koncentrace plynů Oxymetry Kalibrace — Objemový zlomek (analýza plynů) Vnitřní postup; Ve stálé lokalitě (S) Objemový zlomek (analýza plynů) Vnitřní postup Ve stálé lokalitě (S) O₂ O₂ O₂ O₂ O₂ O₂ Vnitřní postup PP.03.02","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče koncentrace plynů\nOxymetry"},{"_id":"9a91546df12f0fee5a5cd5eb","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Płytki wzorcowe (klasy K, 0, 1, 2)","test_object_en":"Gauge blocks (classes K, 0, 1, 2)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,5 mm do 100 mm","cmc":"Q[0,041; 0,11 ∙ 10⁻³ L] µm"}],"parameters_en":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,041; 0,11 ∙ 10⁻³ L] µm"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[0,041; 0,11 ∙ 10⁻³ L] µm\nW stałej lokalizacji (S)","reference":"PN-EN ISO 3650:2000","norm_bases":["PN-EN ISO 3650:2000"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (mm)","note_en":"L - measured quantity (mm)","search_text":"Płytki wzorcowe (klasy K, 0, 1, 2) Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[0,041; 0,11 ∙ 10⁻³ L] µm\nW stałej lokalizacji (S) PN-EN ISO 3650:2000 Plytki wzorcowe (klasy K, 0, 1, 2) Wzorcowanie — Dlugosc\n0,5 mm do 100 mm CMC Q[0,041; 0,11 ∙ 10⁻³ L] µm\nW stalej lokalizacji (S) PN-EN ISO 3650:2000","search_en":"Gauge blocks (classes K, 0, 1, 2) Calibration — Length At permanent location (S) Length At permanent location (S) PN-EN ISO 3650:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,041; 0,11 ∙ 10⁻³ L] µm"}],"regulatory_area_de":"Länge","search_de":"Parallelendmaße (Klassen K, 0, 1, 2) Kalibrierung — Länge Am festen Standort (S) Länge Am festen Standort (S) PN-EN ISO 3650:2000","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Parallelendmaße (Klassen K, 0, 1, 2)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,041; 0,11 ∙ 10⁻³ L] µm"}],"regulatory_area_zh":"长度","search_zh":"量块（K、0、1、2级） 校准 — 长度 在固定地点 (S) 长度 在固定地点 (S) PN-EN ISO 3650:2000","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"量块（K、0、1、2级）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,041; 0,11 ∙ 10⁻³ L] µm"}],"regulatory_area_cs":"Délka","search_cs":"Koncové měrky (třídy K, 0, 1, 2) Kalibrace — Délka Ve stálé lokalitě (S) Délka Ve stálé lokalitě (S) PN-EN ISO 3650:2000","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky (třídy K, 0, 1, 2)"},{"_id":"e252ad367edd7bb3140912f2","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Suwmiarki","test_object_en":"Vernier calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 150 mm","cmc":"19 µm"},{"name":"","range":"150 mm do 300 mm","cmc":"27 µm"}],"parameters_en":[{"name":"","range":"0 mm to 150 mm","cmc":"19 µm"},{"name":"","range":"150 mm to 300 mm","cmc":"27 µm"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 19 µm\n150 mm do 300 mm CMC 27 µm\nW stałej lokalizacji (S)","reference":"PN-EN ISO 13385-1:2019","norm_bases":["PN-EN ISO 13385-1:2019"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Suwmiarki Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 19 µm\n150 mm do 300 mm CMC 27 µm\nW stałej lokalizacji (S) PN-EN ISO 13385-1:2019 Suwmiarki Wzorcowanie — Dlugosc\nZakres:\n0 mm do 150 mm CMC 19 µm\n150 mm do 300 mm CMC 27 µm\nW stalej lokalizacji (S) PN-EN ISO 13385-1:2019","search_en":"Vernier calipers Calibration — Length At permanent location (S) Length At permanent location (S) PN-EN ISO 13385-1:2019","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 150 mm","cmc":"19 µm"},{"name":"","range":"150 mm to 300 mm","cmc":"27 µm"}],"regulatory_area_de":"Länge","search_de":"Messschieber Kalibrierung — Länge Am festen Standort (S) Länge Am festen Standort (S) PN-EN ISO 13385-1:2019","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Messschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 150 mm","cmc":"19 µm"},{"name":"","range":"150 mm to 300 mm","cmc":"27 µm"}],"regulatory_area_zh":"长度","search_zh":"游标卡尺 校准 — 长度 在固定地点 (S) 长度 在固定地点 (S) PN-EN ISO 13385-1:2019","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 150 mm","cmc":"19 µm"},{"name":"","range":"150 mm to 300 mm","cmc":"27 µm"}],"regulatory_area_cs":"Délka","search_cs":"Posuvná měřidla Kalibrace — Délka Ve stálé lokalitě (S) Délka Ve stálé lokalitě (S) PN-EN ISO 13385-1:2019","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Posuvná měřidla"},{"_id":"b0d8406a7a38a2e2d63f0aac","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Kalibratory\nMierniki napięcia cyfrowe\nMultimetry","test_object_en":"Calibrators\nDigital voltmeters\nMultimeters","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV do 2,2 V","cmc":"7 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"2,2 V do 11 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"11 V do 22 V","cmc":"8 · 10⁻⁶ · U"},{"name":"","range":"22 V do 220 V","cmc":"12 · 10⁻⁶ · U"},{"name":"","range":"220 V do 1000 V","cmc":"12 · 10⁻⁶ · U"}],"parameters_en":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 2,2 V","cmc":"7 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"2,2 V to 11 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"11 V to 22 V","cmc":"8 · 10⁻⁶ · U"},{"name":"","range":"22 V to 220 V","cmc":"12 · 10⁻⁶ · U"},{"name":"","range":"220 V to 1000 V","cmc":"12 · 10⁻⁶ · U"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0V CMC 0,1 µV\n1 mV do 2,2 V CMC 7 · 10⁻⁶ · U + 1 µV\n2,2 V do 11 V CMC 9 · 10⁻⁶ · U\n11 V do 22 V CMC 8 · 10⁻⁶ · U\n22 V do 220 V CMC 12 · 10⁻⁶ · U\n220 V do 1000 V CMC 12 · 10⁻⁶ · U\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Kalibratory\nMierniki napięcia cyfrowe\nMultimetry Wzorcowanie — Napięcie DC\nZakres:\n0V CMC 0,1 µV\n1 mV do 2,2 V CMC 7 · 10⁻⁶ · U + 1 µV\n2,2 V do 11 V CMC 9 · 10⁻⁶ · U\n11 V do 22 V CMC 8 · 10⁻⁶ · U\n22 V do 220 V CMC 12 · 10⁻⁶ · U\n220 V do 1000 V CMC 12 · 10⁻⁶ · U\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-15 v.3.0 Kalibratory\nMierniki napiecia cyfrowe\nMultimetry Wzorcowanie — Napiecie DC\nZakres:\n0V CMC 0,1 µV\n1 mV do 2,2 V CMC 7 · 10⁻⁶ · U + 1 µV\n2,2 V do 11 V CMC 9 · 10⁻⁶ · U\n11 V do 22 V CMC 8 · 10⁻⁶ · U\n22 V do 220 V CMC 12 · 10⁻⁶ · U\n220 V do 1000 V CMC 12 · 10⁻⁶ · U\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-15 v.3.0","search_en":"Calibrators Digital voltmeters Multimeters Calibration — DC voltage Direct and indirect method; At permanent location (S) and outside of it (P) DC voltage Direct and indirect method At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 2,2 V","cmc":"7 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"2,2 V to 11 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"11 V to 22 V","cmc":"8 · 10⁻⁶ · U"},{"name":"","range":"22 V to 220 V","cmc":"12 · 10⁻⁶ · U"},{"name":"","range":"220 V to 1000 V","cmc":"12 · 10⁻⁶ · U"}],"regulatory_area_de":"DC-Spannung","search_de":"Kalibratoren Digitale Spannungsmessgeräte Multimeter Kalibrierung — DC-Spannung Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Spannung Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nDigitale Spannungsmessgeräte\nMultimeter","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 2,2 V","cmc":"7 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"2,2 V to 11 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"11 V to 22 V","cmc":"8 · 10⁻⁶ · U"},{"name":"","range":"22 V to 220 V","cmc":"12 · 10⁻⁶ · U"},{"name":"","range":"220 V to 1000 V","cmc":"12 · 10⁻⁶ · U"}],"regulatory_area_zh":"直流电压","search_zh":"校准器 数字电压表 万用表 校准 — 直流电压 直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 直流电压 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n数字电压表\n万用表","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 2,2 V","cmc":"7 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"2,2 V to 11 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"11 V to 22 V","cmc":"8 · 10⁻⁶ · U"},{"name":"","range":"22 V to 220 V","cmc":"12 · 10⁻⁶ · U"},{"name":"","range":"220 V to 1000 V","cmc":"12 · 10⁻⁶ · U"}],"regulatory_area_cs":"Napětí DC","search_cs":"Kalibrátory Digitální měřiče napětí Multimetry Kalibrace — Napětí DC Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Napětí DC Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nDigitální měřiče napětí\nMultimetry"},{"_id":"b8f2d229047a4866a1850029","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Mierniki napięcia analogowe","test_object_en":"Analogue voltmeters","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV do 2,2 V","cmc":"7 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"2,2 V do 11 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"11 V do 22 V","cmc":"8 · 10⁻⁶ · U"},{"name":"","range":"22 V do 220 V","cmc":"12 · 10⁻⁶ · U"},{"name":"","range":"220 V do 1000 V","cmc":"12 · 10⁻⁶ · U"}],"parameters_en":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 2,2 V","cmc":"7 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"2,2 V to 11 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"11 V to 22 V","cmc":"8 · 10⁻⁶ · U"},{"name":"","range":"22 V to 220 V","cmc":"12 · 10⁻⁶ · U"},{"name":"","range":"220 V to 1000 V","cmc":"12 · 10⁻⁶ · U"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0V CMC 0,1 µV\n1 mV do 2,2 V CMC 7 · 10⁻⁶ · U + 1 µV\n2,2 V do 11 V CMC 9 · 10⁻⁶ · U\n11 V do 22 V CMC 8 · 10⁻⁶ · U\n22 V do 220 V CMC 12 · 10⁻⁶ · U\n220 V do 1000 V CMC 12 · 10⁻⁶ · U\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.07.01","norm_bases":["PP.07.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Mierniki napięcia analogowe Wzorcowanie — Napięcie DC\nZakres:\n0V CMC 0,1 µV\n1 mV do 2,2 V CMC 7 · 10⁻⁶ · U + 1 µV\n2,2 V do 11 V CMC 9 · 10⁻⁶ · U\n11 V do 22 V CMC 8 · 10⁻⁶ · U\n22 V do 220 V CMC 12 · 10⁻⁶ · U\n220 V do 1000 V CMC 12 · 10⁻⁶ · U\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.07.01 Mierniki napiecia analogowe Wzorcowanie — Napiecie DC\nZakres:\n0V CMC 0,1 µV\n1 mV do 2,2 V CMC 7 · 10⁻⁶ · U + 1 µV\n2,2 V do 11 V CMC 9 · 10⁻⁶ · U\n11 V do 22 V CMC 8 · 10⁻⁶ · U\n22 V do 220 V CMC 12 · 10⁻⁶ · U\n220 V do 1000 V CMC 12 · 10⁻⁶ · U\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.07.01","search_en":"Analogue voltmeters Calibration — DC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) DC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) Internal procedure PP.07.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.07.01","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 2,2 V","cmc":"7 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"2,2 V to 11 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"11 V to 22 V","cmc":"8 · 10⁻⁶ · U"},{"name":"","range":"22 V to 220 V","cmc":"12 · 10⁻⁶ · U"},{"name":"","range":"220 V to 1000 V","cmc":"12 · 10⁻⁶ · U"}],"reference_de":"Internes Verfahren PP.07.01","regulatory_area_de":"DC-Spannung","search_de":"Analoge Spannungsmessgeräte Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Internes Verfahren PP.07.01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Analoge Spannungsmessgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 2,2 V","cmc":"7 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"2,2 V to 11 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"11 V to 22 V","cmc":"8 · 10⁻⁶ · U"},{"name":"","range":"22 V to 220 V","cmc":"12 · 10⁻⁶ · U"},{"name":"","range":"220 V to 1000 V","cmc":"12 · 10⁻⁶ · U"}],"reference_zh":"内部程序 PP.07.01","regulatory_area_zh":"直流电压","search_zh":"模拟电压表 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 内部程序 PP.07.01","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"模拟电压表","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 2,2 V","cmc":"7 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"2,2 V to 11 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"11 V to 22 V","cmc":"8 · 10⁻⁶ · U"},{"name":"","range":"22 V to 220 V","cmc":"12 · 10⁻⁶ · U"},{"name":"","range":"220 V to 1000 V","cmc":"12 · 10⁻⁶ · U"}],"reference_cs":"Vnitřní postup PP.07.01","regulatory_area_cs":"Napětí DC","search_cs":"Analogové měřiče napětí Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí DC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) Vnitřní postup PP.07.01","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analogové měřiče napětí"},{"_id":"e7f771f0aa3529d67dedcafd","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Zasilacze","test_object_en":"Power supplies","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV do 100 mV","cmc":"8 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"100 mV do 1 V","cmc":"11 · 10⁻⁶ · U"},{"name":"","range":"1 V do 10 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"10 V do 100 V","cmc":"13 · 10⁻⁶ · U"},{"name":"","range":"100 V do 1000 V","cmc":"16 · 10⁻⁶ · U"}],"parameters_en":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 100 mV","cmc":"8 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"11 · 10⁻⁶ · U"},{"name":"","range":"1 V to 10 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"10 V to 100 V","cmc":"13 · 10⁻⁶ · U"},{"name":"","range":"100 V to 1000 V","cmc":"16 · 10⁻⁶ · U"}],"technique":"Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0V CMC 0,1 µV\n1 mV do 100 mV CMC 8 · 10⁻⁶ · U + 1 µV\n100 mV do 1 V CMC 11 · 10⁻⁶ · U\n1 V do 10 V CMC 9 · 10⁻⁶ · U\n10 V do 100 V CMC 13 · 10⁻⁶ · U\n100 V do 1000 V CMC 16 · 10⁻⁶ · U\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Zasilacze Wzorcowanie — Napięcie DC\nZakres:\n0V CMC 0,1 µV\n1 mV do 100 mV CMC 8 · 10⁻⁶ · U + 1 µV\n100 mV do 1 V CMC 11 · 10⁻⁶ · U\n1 V do 10 V CMC 9 · 10⁻⁶ · U\n10 V do 100 V CMC 13 · 10⁻⁶ · U\n100 V do 1000 V CMC 16 · 10⁻⁶ · U\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-15 v.3.0 Zasilacze Wzorcowanie — Napiecie DC\nZakres:\n0V CMC 0,1 µV\n1 mV do 100 mV CMC 8 · 10⁻⁶ · U + 1 µV\n100 mV do 1 V CMC 11 · 10⁻⁶ · U\n1 V do 10 V CMC 9 · 10⁻⁶ · U\n10 V do 100 V CMC 13 · 10⁻⁶ · U\n100 V do 1000 V CMC 16 · 10⁻⁶ · U\nMetoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-15 v.3.0","search_en":"Power supplies Calibration — DC voltage Direct method; At permanent location (S) and outside of it (P) DC voltage Direct method At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 100 mV","cmc":"8 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"11 · 10⁻⁶ · U"},{"name":"","range":"1 V to 10 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"10 V to 100 V","cmc":"13 · 10⁻⁶ · U"},{"name":"","range":"100 V to 1000 V","cmc":"16 · 10⁻⁶ · U"}],"regulatory_area_de":"DC-Spannung","search_de":"Netzgeräte Kalibrierung — DC-Spannung Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P) DC-Spannung Direktes Verfahren Am festen Standort (S) und außerhalb (P) EURAMET cg-15 v.3.0","technique_de":"Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P)","techniques_de":["Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 100 mV","cmc":"8 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"11 · 10⁻⁶ · U"},{"name":"","range":"1 V to 10 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"10 V to 100 V","cmc":"13 · 10⁻⁶ · U"},{"name":"","range":"100 V to 1000 V","cmc":"16 · 10⁻⁶ · U"}],"regulatory_area_zh":"直流电压","search_zh":"电源 校准 — 直流电压 直接法；在固定地点 (S) 及固定地点以外 (P) 直流电压 直接法 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-15 v.3.0","technique_zh":"直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0V","cmc":"0,1 µV"},{"name":"","range":"1 mV to 100 mV","cmc":"8 · 10⁻⁶ · U + 1 µV"},{"name":"","range":"100 mV to 1 V","cmc":"11 · 10⁻⁶ · U"},{"name":"","range":"1 V to 10 V","cmc":"9 · 10⁻⁶ · U"},{"name":"","range":"10 V to 100 V","cmc":"13 · 10⁻⁶ · U"},{"name":"","range":"100 V to 1000 V","cmc":"16 · 10⁻⁶ · U"}],"regulatory_area_cs":"Napětí DC","search_cs":"Napájecí zdroje Kalibrace — Napětí DC Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P) Napětí DC Přímá metoda V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-15 v.3.0","technique_cs":"Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Napájecí zdroje"},{"_id":"9572d4b054a28901f8910a90","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Kalibratory\nMierniki prądu cyfrowe\nMultimetry\nZasilacze","test_object_en":"Calibrators\nDigital ammeters\nMultimeters\nPower supplies","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,1 µA do 1 µA","cmc":"35 · 10⁻⁶ · I + 21 pA"},{"name":"","range":"1 µA do 10 µA","cmc":"50 · 10⁻⁶ · I + 6 pA"},{"name":"","range":"10 µA do 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"100 µA do 320 mA","cmc":"18 · 10⁻⁶ · I"},{"name":"","range":"320 mA do 1 A","cmc":"15 · 10⁻⁶ · I + 6 µA"},{"name":"","range":"1 A do 10 A","cmc":"0,2 · 10⁻³ · I"},{"name":"","range":"10 A do 150 A","cmc":"0,3 · 10⁻³· I"}],"parameters_en":[{"name":"","range":"0,1 µA to 1 µA","cmc":"35 · 10⁻⁶ · I + 21 pA"},{"name":"","range":"1 µA to 10 µA","cmc":"50 · 10⁻⁶ · I + 6 pA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"100 µA to 320 mA","cmc":"18 · 10⁻⁶ · I"},{"name":"","range":"320 mA to 1 A","cmc":"15 · 10⁻⁶ · I + 6 µA"},{"name":"","range":"1 A to 10 A","cmc":"0,2 · 10⁻³ · I"},{"name":"","range":"10 A to 150 A","cmc":"0,3 · 10⁻³· I"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,1 µA do 1 µA CMC 35 · 10⁻⁶ · I + 21 pA\n1 µA do 10 µA CMC 50 · 10⁻⁶ · I + 6 pA\n10 µA do 100 µA CMC 15 · 10⁻⁶ · I + 0,4 nA\n100 µA do 320 mA CMC 18 · 10⁻⁶ · I\n320 mA do 1 A CMC 15 · 10⁻⁶ · I + 6 µA\n1 A do 10 A CMC 0,2 · 10⁻³ · I\n10 A do 150 A CMC 0,3 · 10⁻³· I\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Kalibratory\nMierniki prądu cyfrowe\nMultimetry\nZasilacze Wzorcowanie — Prąd DC\nZakres:\n0,1 µA do 1 µA CMC 35 · 10⁻⁶ · I + 21 pA\n1 µA do 10 µA CMC 50 · 10⁻⁶ · I + 6 pA\n10 µA do 100 µA CMC 15 · 10⁻⁶ · I + 0,4 nA\n100 µA do 320 mA CMC 18 · 10⁻⁶ · I\n320 mA do 1 A CMC 15 · 10⁻⁶ · I + 6 µA\n1 A do 10 A CMC 0,2 · 10⁻³ · I\n10 A do 150 A CMC 0,3 · 10⁻³· I\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-15 v.3.0 Kalibratory\nMierniki pradu cyfrowe\nMultimetry\nZasilacze Wzorcowanie — Prad DC\nZakres:\n0,1 µA do 1 µA CMC 35 · 10⁻⁶ · I + 21 pA\n1 µA do 10 µA CMC 50 · 10⁻⁶ · I + 6 pA\n10 µA do 100 µA CMC 15 · 10⁻⁶ · I + 0,4 nA\n100 µA do 320 mA CMC 18 · 10⁻⁶ · I\n320 mA do 1 A CMC 15 · 10⁻⁶ · I + 6 µA\n1 A do 10 A CMC 0,2 · 10⁻³ · I\n10 A do 150 A CMC 0,3 · 10⁻³· I\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-15 v.3.0","search_en":"Calibrators Digital ammeters Multimeters Power supplies Calibration — DC current Direct and indirect method; At permanent location (S) and outside of it (P) DC current Direct and indirect method At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,1 µA to 1 µA","cmc":"35 · 10⁻⁶ · I + 21 pA"},{"name":"","range":"1 µA to 10 µA","cmc":"50 · 10⁻⁶ · I + 6 pA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"100 µA to 320 mA","cmc":"18 · 10⁻⁶ · I"},{"name":"","range":"320 mA to 1 A","cmc":"15 · 10⁻⁶ · I + 6 µA"},{"name":"","range":"1 A to 10 A","cmc":"0,2 · 10⁻³ · I"},{"name":"","range":"10 A to 150 A","cmc":"0,3 · 10⁻³· I"}],"regulatory_area_de":"DC-Strom","search_de":"Kalibratoren Digitale Strommessgeräte Multimeter Netzgeräte Kalibrierung — DC-Strom Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Strom Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nDigitale Strommessgeräte\nMultimeter\nNetzgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,1 µA to 1 µA","cmc":"35 · 10⁻⁶ · I + 21 pA"},{"name":"","range":"1 µA to 10 µA","cmc":"50 · 10⁻⁶ · I + 6 pA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"100 µA to 320 mA","cmc":"18 · 10⁻⁶ · I"},{"name":"","range":"320 mA to 1 A","cmc":"15 · 10⁻⁶ · I + 6 µA"},{"name":"","range":"1 A to 10 A","cmc":"0,2 · 10⁻³ · I"},{"name":"","range":"10 A to 150 A","cmc":"0,3 · 10⁻³· I"}],"regulatory_area_zh":"直流电流","search_zh":"校准器 数字电流表 万用表 电源 校准 — 直流电流 直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 直流电流 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n数字电流表\n万用表\n电源","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,1 µA to 1 µA","cmc":"35 · 10⁻⁶ · I + 21 pA"},{"name":"","range":"1 µA to 10 µA","cmc":"50 · 10⁻⁶ · I + 6 pA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"100 µA to 320 mA","cmc":"18 · 10⁻⁶ · I"},{"name":"","range":"320 mA to 1 A","cmc":"15 · 10⁻⁶ · I + 6 µA"},{"name":"","range":"1 A to 10 A","cmc":"0,2 · 10⁻³ · I"},{"name":"","range":"10 A to 150 A","cmc":"0,3 · 10⁻³· I"}],"regulatory_area_cs":"Proud DC","search_cs":"Kalibrátory Digitální měřiče proudu Multimetry Napájecí zdroje Kalibrace — Proud DC Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Proud DC Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nDigitální měřiče proudu\nMultimetry\nNapájecí zdroje"},{"_id":"d4efcaf99eb23e5ca1f2df5d","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Mierniki prądu analogowe","test_object_en":"Analogue ammeters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,1 µA do 1 µA","cmc":"35 · 10⁻⁶ · I + 21 pA"},{"name":"","range":"1 µA do 10 µA","cmc":"50 · 10⁻⁶ · I + 6 pA"},{"name":"","range":"10 µA do 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"100 µA do 320 mA","cmc":"18 · 10⁻⁶ · I"},{"name":"","range":"320 mA do 1 A","cmc":"15 · 10⁻⁶ · I + 6 µA"},{"name":"","range":"1 A do 10 A","cmc":"0,2 · 10⁻³ · I"},{"name":"","range":"10 A do 150 A","cmc":"0,3 · 10⁻³· I"}],"parameters_en":[{"name":"","range":"0,1 µA to 1 µA","cmc":"35 · 10⁻⁶ · I + 21 pA"},{"name":"","range":"1 µA to 10 µA","cmc":"50 · 10⁻⁶ · I + 6 pA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"100 µA to 320 mA","cmc":"18 · 10⁻⁶ · I"},{"name":"","range":"320 mA to 1 A","cmc":"15 · 10⁻⁶ · I + 6 µA"},{"name":"","range":"1 A to 10 A","cmc":"0,2 · 10⁻³ · I"},{"name":"","range":"10 A to 150 A","cmc":"0,3 · 10⁻³· I"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,1 µA do 1 µA CMC 35 · 10⁻⁶ · I + 21 pA\n1 µA do 10 µA CMC 50 · 10⁻⁶ · I + 6 pA\n10 µA do 100 µA CMC 15 · 10⁻⁶ · I + 0,4 nA\n100 µA do 320 mA CMC 18 · 10⁻⁶ · I\n320 mA do 1 A CMC 15 · 10⁻⁶ · I + 6 µA\n1 A do 10 A CMC 0,2 · 10⁻³ · I\n10 A do 150 A CMC 0,3 · 10⁻³· I\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.07.01","norm_bases":["PP.07.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Mierniki prądu analogowe Wzorcowanie — Prąd DC\nZakres:\n0,1 µA do 1 µA CMC 35 · 10⁻⁶ · I + 21 pA\n1 µA do 10 µA CMC 50 · 10⁻⁶ · I + 6 pA\n10 µA do 100 µA CMC 15 · 10⁻⁶ · I + 0,4 nA\n100 µA do 320 mA CMC 18 · 10⁻⁶ · I\n320 mA do 1 A CMC 15 · 10⁻⁶ · I + 6 µA\n1 A do 10 A CMC 0,2 · 10⁻³ · I\n10 A do 150 A CMC 0,3 · 10⁻³· I\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.07.01 Mierniki pradu analogowe Wzorcowanie — Prad DC\nZakres:\n0,1 µA do 1 µA CMC 35 · 10⁻⁶ · I + 21 pA\n1 µA do 10 µA CMC 50 · 10⁻⁶ · I + 6 pA\n10 µA do 100 µA CMC 15 · 10⁻⁶ · I + 0,4 nA\n100 µA do 320 mA CMC 18 · 10⁻⁶ · I\n320 mA do 1 A CMC 15 · 10⁻⁶ · I + 6 µA\n1 A do 10 A CMC 0,2 · 10⁻³ · I\n10 A do 150 A CMC 0,3 · 10⁻³· I\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.07.01","search_en":"Analogue ammeters Calibration — DC current Internal procedure; Direct method; At permanent location (S) and outside of it (P) DC current Internal procedure Direct method At permanent location (S) and outside of it (P) Internal procedure PP.07.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.07.01","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,1 µA to 1 µA","cmc":"35 · 10⁻⁶ · I + 21 pA"},{"name":"","range":"1 µA to 10 µA","cmc":"50 · 10⁻⁶ · I + 6 pA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"100 µA to 320 mA","cmc":"18 · 10⁻⁶ · I"},{"name":"","range":"320 mA to 1 A","cmc":"15 · 10⁻⁶ · I + 6 µA"},{"name":"","range":"1 A to 10 A","cmc":"0,2 · 10⁻³ · I"},{"name":"","range":"10 A to 150 A","cmc":"0,3 · 10⁻³· I"}],"reference_de":"Internes Verfahren PP.07.01","regulatory_area_de":"DC-Strom","search_de":"Analoge Strommessgeräte Kalibrierung — DC-Strom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Internes Verfahren PP.07.01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Analoge Strommessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,1 µA to 1 µA","cmc":"35 · 10⁻⁶ · I + 21 pA"},{"name":"","range":"1 µA to 10 µA","cmc":"50 · 10⁻⁶ · I + 6 pA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"100 µA to 320 mA","cmc":"18 · 10⁻⁶ · I"},{"name":"","range":"320 mA to 1 A","cmc":"15 · 10⁻⁶ · I + 6 µA"},{"name":"","range":"1 A to 10 A","cmc":"0,2 · 10⁻³ · I"},{"name":"","range":"10 A to 150 A","cmc":"0,3 · 10⁻³· I"}],"reference_zh":"内部程序 PP.07.01","regulatory_area_zh":"直流电流","search_zh":"模拟电流表 校准 — 直流电流 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流电流 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 内部程序 PP.07.01","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"模拟电流表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,1 µA to 1 µA","cmc":"35 · 10⁻⁶ · I + 21 pA"},{"name":"","range":"1 µA to 10 µA","cmc":"50 · 10⁻⁶ · I + 6 pA"},{"name":"","range":"10 µA to 100 µA","cmc":"15 · 10⁻⁶ · I + 0,4 nA"},{"name":"","range":"100 µA to 320 mA","cmc":"18 · 10⁻⁶ · I"},{"name":"","range":"320 mA to 1 A","cmc":"15 · 10⁻⁶ · I + 6 µA"},{"name":"","range":"1 A to 10 A","cmc":"0,2 · 10⁻³ · I"},{"name":"","range":"10 A to 150 A","cmc":"0,3 · 10⁻³· I"}],"reference_cs":"Vnitřní postup PP.07.01","regulatory_area_cs":"Proud DC","search_cs":"Analogové měřiče proudu Kalibrace — Proud DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Proud DC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) Vnitřní postup PP.07.01","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analogové měřiče proudu"},{"_id":"fd8fc29ab8d0ee25a019c082","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"1 mA do 2,2 A","cmc":"1 · 10⁻³ · I"},{"name":"","range":"2,2 A do 20 A","cmc":"2 · 10⁻³ · I"},{"name":"","range":"20 A do 1000 A","cmc":"3 · 10⁻³ · I"}],"parameters_en":[{"name":"","range":"1 mA to 2,2 A","cmc":"1 · 10⁻³ · I"},{"name":"","range":"2,2 A to 20 A","cmc":"2 · 10⁻³ · I"},{"name":"","range":"20 A to 1000 A","cmc":"3 · 10⁻³ · I"}],"technique":"Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n1 mA do 2,2 A CMC 1 · 10⁻³ · I\n2,2 A do 20 A CMC 2 · 10⁻³ · I\n20 A do 1000 A CMC 3 · 10⁻³ · I\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Mierniki cęgowe Wzorcowanie — Prąd DC\nZakres:\n1 mA do 2,2 A CMC 1 · 10⁻³ · I\n2,2 A do 20 A CMC 2 · 10⁻³ · I\n20 A do 1000 A CMC 3 · 10⁻³ · I\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-15 v.3.0 Mierniki cegowe Wzorcowanie — Prad DC\nZakres:\n1 mA do 2,2 A CMC 1 · 10⁻³ · I\n2,2 A do 20 A CMC 2 · 10⁻³ · I\n20 A do 1000 A CMC 3 · 10⁻³ · I\nMetoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-15 v.3.0","search_en":"Clamp meters Calibration — DC current Direct method; At permanent location (S) and outside of it (P) DC current Direct method At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"1 mA to 2,2 A","cmc":"1 · 10⁻³ · I"},{"name":"","range":"2,2 A to 20 A","cmc":"2 · 10⁻³ · I"},{"name":"","range":"20 A to 1000 A","cmc":"3 · 10⁻³ · I"}],"regulatory_area_de":"DC-Strom","search_de":"Zangenmessgeräte Kalibrierung — DC-Strom Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P) DC-Strom Direktes Verfahren Am festen Standort (S) und außerhalb (P) EURAMET cg-15 v.3.0","technique_de":"Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P)","techniques_de":["Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"1 mA to 2,2 A","cmc":"1 · 10⁻³ · I"},{"name":"","range":"2,2 A to 20 A","cmc":"2 · 10⁻³ · I"},{"name":"","range":"20 A to 1000 A","cmc":"3 · 10⁻³ · I"}],"regulatory_area_zh":"直流电流","search_zh":"钳形表 校准 — 直流电流 直接法；在固定地点 (S) 及固定地点以外 (P) 直流电流 直接法 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-15 v.3.0","technique_zh":"直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"1 mA to 2,2 A","cmc":"1 · 10⁻³ · I"},{"name":"","range":"2,2 A to 20 A","cmc":"2 · 10⁻³ · I"},{"name":"","range":"20 A to 1000 A","cmc":"3 · 10⁻³ · I"}],"regulatory_area_cs":"Proud DC","search_cs":"Klešťové měřiče Kalibrace — Proud DC Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P) Proud DC Přímá metoda V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-15 v.3.0","technique_cs":"Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Klešťové měřiče"},{"_id":"f6289903ce5997fc9abe2305","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Kalibratory\nMierniki napięcia cyfrowe\nMultimetry","test_object_en":"Calibrators\nDigital voltmeters\nMultimeters","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"10 Hz do 20 Hz","range":"1 mV do 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"10 Hz do 20 Hz","range":"2,2 mV do 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"10 Hz do 20 Hz","range":"7 mV do 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"22 mV do 70 mV","cmc":"70 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"70 mV do 220 mV","cmc":"39 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"220 mV do 700 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"700 mV do 2,2V","cmc":"20 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"2,2 V do 7 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"7 V do 22 V","cmc":"17 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"22 V do 70 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"70 V do 220 V","cmc":"19 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"220 V do 1000 V","cmc":"25 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"1 mV do 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"20 Hz do 40 Hz","range":"2,2 mV do 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"20 Hz do 40 Hz","range":"7 mV do 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"22 mV do 70 mV","cmc":"58 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"70 mV do 220 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"220 mV do 700 mV","cmc":"22 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"700 mV do 2,2 V","cmc":"14 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"2,2 V do 7 V","cmc":"12 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"7 V do 22 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"22 V do 70 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"70 V do 220 V","cmc":"18 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"220 V do 1000 V","cmc":"27 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"1 mV do 2,2 mV","cmc":"0,4 · 10⁻³ · U"},{"name":"40 Hz do 20 kHz","range":"2,2 mV do 7 mV","cmc":"0,16 · 10⁻³ · U"},{"name":"40 Hz do 20 kHz","range":"7 mV do 22 mV","cmc":"65 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"22 mV do 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"70 mV do 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"220 mV do 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"700 mV do 2,2 V","cmc":"10 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"2,2 V do 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"7 V do 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"22 V do 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"70 V do 220 V","cmc":"17 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"220 V do 1000 V","cmc":"45 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"1 mV do 2,2 mV","cmc":"0,4 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"2,2 mV do 7 mV","cmc":"0,16 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"7 mV do 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"22 mV do 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"70 mV do 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"220 mV do 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"700 mV do 2,2V","cmc":"10 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"2,2 V do 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"7 V do 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"22 V do 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"70 V do 220 V","cmc":"27 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"220 V do 1000 V","cmc":"45 · 10⁻⁶ · U"}],"parameters_en":[{"name":"10 Hz to 20 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"10 Hz to 20 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"10 Hz to 20 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"22 mV to 70 mV","cmc":"70 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"70 mV to 220 mV","cmc":"39 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"220 mV to 700 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"700 mV to 2,2V","cmc":"20 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"2,2 V to 7 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"7 V to 22 V","cmc":"17 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"22 V to 70 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"70 V to 220 V","cmc":"19 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"220 V to 1000 V","cmc":"25 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"20 Hz to 40 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"20 Hz to 40 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"22 mV to 70 mV","cmc":"58 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"70 mV to 220 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"220 mV to 700 mV","cmc":"22 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"700 mV to 2,2 V","cmc":"14 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"2,2 V to 7 V","cmc":"12 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"7 V to 22 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"22 V to 70 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"70 V to 220 V","cmc":"18 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"220 V to 1000 V","cmc":"27 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻³ · U"},{"name":"40 Hz to 20 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻³ · U"},{"name":"40 Hz to 20 kHz","range":"7 mV to 22 mV","cmc":"65 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"700 mV to 2,2 V","cmc":"10 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"70 V to 220 V","cmc":"17 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"700 mV to 2,2V","cmc":"10 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"70 V to 220 V","cmc":"27 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 20 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n10 Hz do 20 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n10 Hz do 20 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 mV do 70 mV CMC 70 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 mV do 220 mV CMC 39 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 mV do 700 mV CMC 25 · 10⁻⁶ · U\n10 Hz do 20 Hz 700 mV do 2,2V CMC 20 · 10⁻⁶ · U\n10 Hz do 20 Hz 2,2 V do 7 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 7 V do 22 V CMC 17 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 V do 70 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 V do 220 V CMC 19 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 V do 1000 V CMC 25 · 10⁻⁶ · U\n20 Hz do 40 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n20 Hz do 40 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n20 Hz do 40 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 mV do 70 mV CMC 58 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 mV do 220 mV CMC 35 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 mV do 700 mV CMC 22 · 10⁻⁶ · U\n20 Hz do 40 Hz 700 mV do 2,2 V CMC 14 · 10⁻⁶ · U\n20 Hz do 40 Hz 2,2 V do 7 V CMC 12 · 10⁻⁶ · U\n20 Hz do 40 Hz 7 V do 22 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 V do 70 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 V do 220 V CMC 18 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 V do 1000 V CMC 27 · 10⁻⁶ · U\n40 Hz do 20 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻³ · U\n40 Hz do 20 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻³ · U\n40 Hz do 20 kHz 7 mV do 22 mV CMC 65 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n40 Hz do 20 kHz 700 mV do 2,2 V CMC 10 · 10⁻⁶ · U\n40 Hz do 20 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 V do 220 V CMC 17 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\n20 kHz do 50 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n20 kHz do 50 kHz 700 mV do 2,2V CMC 10 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 V do 220 V CMC 27 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Kalibratory\nMierniki napięcia cyfrowe\nMultimetry Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 20 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n10 Hz do 20 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n10 Hz do 20 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 mV do 70 mV CMC 70 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 mV do 220 mV CMC 39 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 mV do 700 mV CMC 25 · 10⁻⁶ · U\n10 Hz do 20 Hz 700 mV do 2,2V CMC 20 · 10⁻⁶ · U\n10 Hz do 20 Hz 2,2 V do 7 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 7 V do 22 V CMC 17 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 V do 70 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 V do 220 V CMC 19 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 V do 1000 V CMC 25 · 10⁻⁶ · U\n20 Hz do 40 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n20 Hz do 40 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n20 Hz do 40 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 mV do 70 mV CMC 58 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 mV do 220 mV CMC 35 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 mV do 700 mV CMC 22 · 10⁻⁶ · U\n20 Hz do 40 Hz 700 mV do 2,2 V CMC 14 · 10⁻⁶ · U\n20 Hz do 40 Hz 2,2 V do 7 V CMC 12 · 10⁻⁶ · U\n20 Hz do 40 Hz 7 V do 22 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 V do 70 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 V do 220 V CMC 18 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 V do 1000 V CMC 27 · 10⁻⁶ · U\n40 Hz do 20 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻³ · U\n40 Hz do 20 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻³ · U\n40 Hz do 20 kHz 7 mV do 22 mV CMC 65 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n40 Hz do 20 kHz 700 mV do 2,2 V CMC 10 · 10⁻⁶ · U\n40 Hz do 20 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 V do 220 V CMC 17 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\n20 kHz do 50 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n20 kHz do 50 kHz 700 mV do 2,2V CMC 10 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 V do 220 V CMC 27 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-15 v.3.0 Kalibratory\nMierniki napiecia cyfrowe\nMultimetry Wzorcowanie — Napiecie AC\nZakres:\n10 Hz do 20 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n10 Hz do 20 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n10 Hz do 20 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 mV do 70 mV CMC 70 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 mV do 220 mV CMC 39 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 mV do 700 mV CMC 25 · 10⁻⁶ · U\n10 Hz do 20 Hz 700 mV do 2,2V CMC 20 · 10⁻⁶ · U\n10 Hz do 20 Hz 2,2 V do 7 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 7 V do 22 V CMC 17 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 V do 70 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 V do 220 V CMC 19 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 V do 1000 V CMC 25 · 10⁻⁶ · U\n20 Hz do 40 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n20 Hz do 40 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n20 Hz do 40 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 mV do 70 mV CMC 58 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 mV do 220 mV CMC 35 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 mV do 700 mV CMC 22 · 10⁻⁶ · U\n20 Hz do 40 Hz 700 mV do 2,2 V CMC 14 · 10⁻⁶ · U\n20 Hz do 40 Hz 2,2 V do 7 V CMC 12 · 10⁻⁶ · U\n20 Hz do 40 Hz 7 V do 22 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 V do 70 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 V do 220 V CMC 18 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 V do 1000 V CMC 27 · 10⁻⁶ · U\n40 Hz do 20 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻³ · U\n40 Hz do 20 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻³ · U\n40 Hz do 20 kHz 7 mV do 22 mV CMC 65 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n40 Hz do 20 kHz 700 mV do 2,2 V CMC 10 · 10⁻⁶ · U\n40 Hz do 20 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 V do 220 V CMC 17 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\n20 kHz do 50 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n20 kHz do 50 kHz 700 mV do 2,2V CMC 10 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 V do 220 V CMC 27 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-15 v.3.0","search_en":"Calibrators Digital voltmeters Multimeters Calibration — AC voltage Direct and indirect method; At permanent location (S) and outside of it (P) AC voltage Direct and indirect method At permanent location (S) and outside of it (P) 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"10 Hz bis 20 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"10 Hz bis 20 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"10 Hz bis 20 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"22 mV to 70 mV","cmc":"70 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"70 mV to 220 mV","cmc":"39 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"220 mV to 700 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"700 mV to 2,2V","cmc":"20 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"2,2 V to 7 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"7 V to 22 V","cmc":"17 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"22 V to 70 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"70 V to 220 V","cmc":"19 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"220 V to 1000 V","cmc":"25 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"20 Hz bis 40 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"20 Hz bis 40 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"22 mV to 70 mV","cmc":"58 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"70 mV to 220 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"220 mV to 700 mV","cmc":"22 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"700 mV to 2,2 V","cmc":"14 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"2,2 V to 7 V","cmc":"12 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"7 V to 22 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"22 V to 70 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"70 V to 220 V","cmc":"18 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"220 V to 1000 V","cmc":"27 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻³ · U"},{"name":"40 Hz bis 20 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻³ · U"},{"name":"40 Hz bis 20 kHz","range":"7 mV to 22 mV","cmc":"65 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"700 mV to 2,2 V","cmc":"10 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"70 V to 220 V","cmc":"17 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"700 mV to 2,2V","cmc":"10 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"70 V to 220 V","cmc":"27 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"}],"regulatory_area_de":"AC-Spannung","search_de":"Kalibratoren Digitale Spannungsmessgeräte Multimeter Kalibrierung — Wechselspannung Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nDigitale Spannungsmessgeräte\nMultimeter","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"10 Hz 至 20 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"10 Hz 至 20 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"10 Hz 至 20 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"22 mV to 70 mV","cmc":"70 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"70 mV to 220 mV","cmc":"39 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"220 mV to 700 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"700 mV to 2,2V","cmc":"20 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"2,2 V to 7 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"7 V to 22 V","cmc":"17 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"22 V to 70 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"70 V to 220 V","cmc":"19 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"220 V to 1000 V","cmc":"25 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"20 Hz 至 40 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"20 Hz 至 40 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"22 mV to 70 mV","cmc":"58 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"70 mV to 220 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"220 mV to 700 mV","cmc":"22 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"700 mV to 2,2 V","cmc":"14 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"2,2 V to 7 V","cmc":"12 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"7 V to 22 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"22 V to 70 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"70 V to 220 V","cmc":"18 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"220 V to 1000 V","cmc":"27 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻³ · U"},{"name":"40 Hz 至 20 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻³ · U"},{"name":"40 Hz 至 20 kHz","range":"7 mV to 22 mV","cmc":"65 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"700 mV to 2,2 V","cmc":"10 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"70 V to 220 V","cmc":"17 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"700 mV to 2,2V","cmc":"10 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"70 V to 220 V","cmc":"27 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"}],"regulatory_area_zh":"交流电压","search_zh":"校准器 数字电压表 万用表 校准 — 交流电压 直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n数字电压表\n万用表","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"10 Hz až 20 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"10 Hz až 20 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"10 Hz až 20 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"22 mV to 70 mV","cmc":"70 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"70 mV to 220 mV","cmc":"39 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"220 mV to 700 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"700 mV to 2,2V","cmc":"20 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"2,2 V to 7 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"7 V to 22 V","cmc":"17 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"22 V to 70 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"70 V to 220 V","cmc":"19 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"220 V to 1000 V","cmc":"25 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"20 Hz až 40 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"20 Hz až 40 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"22 mV to 70 mV","cmc":"58 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"70 mV to 220 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"220 mV to 700 mV","cmc":"22 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"700 mV to 2,2 V","cmc":"14 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"2,2 V to 7 V","cmc":"12 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"7 V to 22 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"22 V to 70 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"70 V to 220 V","cmc":"18 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"220 V to 1000 V","cmc":"27 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻³ · U"},{"name":"40 Hz až 20 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻³ · U"},{"name":"40 Hz až 20 kHz","range":"7 mV to 22 mV","cmc":"65 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"700 mV to 2,2 V","cmc":"10 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"70 V to 220 V","cmc":"17 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"700 mV to 2,2V","cmc":"10 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"70 V to 220 V","cmc":"27 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"}],"regulatory_area_cs":"Napětí AC","search_cs":"Kalibrátory Digitální měřiče napětí Multimetry Kalibrace — Napětí AC Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Napětí AC Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nDigitální měřiče napětí\nMultimetry"},{"_id":"123c2461686aefe56685cd1d","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Mierniki napięcia analogowe","test_object_en":"Analogue voltmeters","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"10 Hz do 20 Hz","range":"1 mV do 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"10 Hz do 20 Hz","range":"2,2 mV do 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"10 Hz do 20 Hz","range":"7 mV do 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"22 mV do 70 mV","cmc":"70 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"70 mV do 220 mV","cmc":"39 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"220 mV do 700 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"700 mV do 2,2V","cmc":"20 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"2,2 V do 7 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"7 V do 22 V","cmc":"17 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"22 V do 70 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"70 V do 220 V","cmc":"19 · 10⁻⁶ · U"},{"name":"10 Hz do 20 Hz","range":"220 V do 1000 V","cmc":"25 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"1 mV do 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"20 Hz do 40 Hz","range":"2,2 mV do 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"20 Hz do 40 Hz","range":"7 mV do 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"22 mV do 70 mV","cmc":"58 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"70 mV do 220 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"220 mV do 700 mV","cmc":"22 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"700 mV do 2,2 V","cmc":"14 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"2,2 V do 7 V","cmc":"12 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"7 V do 22 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"22 V do 70 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"70 V do 220 V","cmc":"18 · 10⁻⁶ · U"},{"name":"20 Hz do 40 Hz","range":"220 V do 1000 V","cmc":"27 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"1 mV do 2,2 mV","cmc":"0,4 · 10⁻³ · U"},{"name":"40 Hz do 20 kHz","range":"2,2 mV do 7 mV","cmc":"0,16 · 10⁻³ · U"},{"name":"40 Hz do 20 kHz","range":"7 mV do 22 mV","cmc":"65 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"22 mV do 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"70 mV do 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"220 mV do 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"700 mV do 2,2 V","cmc":"10 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"2,2 V do 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"7 V do 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"22 V do 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"70 V do 220 V","cmc":"17 · 10⁻⁶ · U"},{"name":"40 Hz do 20 kHz","range":"220 V do 1000 V","cmc":"45 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"1 mV do 2,2 mV","cmc":"0,4 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"2,2 mV do 7 mV","cmc":"0,16 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"7 mV do 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"22 mV do 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"70 mV do 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"220 mV do 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"700 mV do 2,2V","cmc":"10 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"2,2 V do 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"7 V do 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"22 V do 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"70 V do 220 V","cmc":"27 · 10⁻⁶ · U"},{"name":"20 kHz do 50 kHz","range":"220 V do 1000 V","cmc":"45 · 10⁻⁶ · U"}],"parameters_en":[{"name":"10 Hz to 20 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"10 Hz to 20 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"10 Hz to 20 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"22 mV to 70 mV","cmc":"70 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"70 mV to 220 mV","cmc":"39 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"220 mV to 700 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"700 mV to 2,2V","cmc":"20 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"2,2 V to 7 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"7 V to 22 V","cmc":"17 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"22 V to 70 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"70 V to 220 V","cmc":"19 · 10⁻⁶ · U"},{"name":"10 Hz to 20 Hz","range":"220 V to 1000 V","cmc":"25 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"20 Hz to 40 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"20 Hz to 40 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"22 mV to 70 mV","cmc":"58 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"70 mV to 220 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"220 mV to 700 mV","cmc":"22 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"700 mV to 2,2 V","cmc":"14 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"2,2 V to 7 V","cmc":"12 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"7 V to 22 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"22 V to 70 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"70 V to 220 V","cmc":"18 · 10⁻⁶ · U"},{"name":"20 Hz to 40 Hz","range":"220 V to 1000 V","cmc":"27 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻³ · U"},{"name":"40 Hz to 20 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻³ · U"},{"name":"40 Hz to 20 kHz","range":"7 mV to 22 mV","cmc":"65 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"700 mV to 2,2 V","cmc":"10 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"70 V to 220 V","cmc":"17 · 10⁻⁶ · U"},{"name":"40 Hz to 20 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"700 mV to 2,2V","cmc":"10 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"70 V to 220 V","cmc":"27 · 10⁻⁶ · U"},{"name":"20 kHz to 50 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 20 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n10 Hz do 20 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n10 Hz do 20 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 mV do 70 mV CMC 70 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 mV do 220 mV CMC 39 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 mV do 700 mV CMC 25 · 10⁻⁶ · U\n10 Hz do 20 Hz 700 mV do 2,2V CMC 20 · 10⁻⁶ · U\n10 Hz do 20 Hz 2,2 V do 7 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 7 V do 22 V CMC 17 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 V do 70 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 V do 220 V CMC 19 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 V do 1000 V CMC 25 · 10⁻⁶ · U\n20 Hz do 40 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n20 Hz do 40 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n20 Hz do 40 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 mV do 70 mV CMC 58 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 mV do 220 mV CMC 35 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 mV do 700 mV CMC 22 · 10⁻⁶ · U\n20 Hz do 40 Hz 700 mV do 2,2 V CMC 14 · 10⁻⁶ · U\n20 Hz do 40 Hz 2,2 V do 7 V CMC 12 · 10⁻⁶ · U\n20 Hz do 40 Hz 7 V do 22 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 V do 70 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 V do 220 V CMC 18 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 V do 1000 V CMC 27 · 10⁻⁶ · U\n40 Hz do 20 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻³ · U\n40 Hz do 20 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻³ · U\n40 Hz do 20 kHz 7 mV do 22 mV CMC 65 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n40 Hz do 20 kHz 700 mV do 2,2 V CMC 10 · 10⁻⁶ · U\n40 Hz do 20 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 V do 220 V CMC 17 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\n20 kHz do 50 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n20 kHz do 50 kHz 700 mV do 2,2V CMC 10 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 V do 220 V CMC 27 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.07.01","norm_bases":["PP.07.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Mierniki napięcia analogowe Wzorcowanie — Napięcie AC\nZakres:\n10 Hz do 20 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n10 Hz do 20 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n10 Hz do 20 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 mV do 70 mV CMC 70 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 mV do 220 mV CMC 39 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 mV do 700 mV CMC 25 · 10⁻⁶ · U\n10 Hz do 20 Hz 700 mV do 2,2V CMC 20 · 10⁻⁶ · U\n10 Hz do 20 Hz 2,2 V do 7 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 7 V do 22 V CMC 17 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 V do 70 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 V do 220 V CMC 19 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 V do 1000 V CMC 25 · 10⁻⁶ · U\n20 Hz do 40 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n20 Hz do 40 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n20 Hz do 40 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 mV do 70 mV CMC 58 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 mV do 220 mV CMC 35 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 mV do 700 mV CMC 22 · 10⁻⁶ · U\n20 Hz do 40 Hz 700 mV do 2,2 V CMC 14 · 10⁻⁶ · U\n20 Hz do 40 Hz 2,2 V do 7 V CMC 12 · 10⁻⁶ · U\n20 Hz do 40 Hz 7 V do 22 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 V do 70 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 V do 220 V CMC 18 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 V do 1000 V CMC 27 · 10⁻⁶ · U\n40 Hz do 20 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻³ · U\n40 Hz do 20 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻³ · U\n40 Hz do 20 kHz 7 mV do 22 mV CMC 65 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n40 Hz do 20 kHz 700 mV do 2,2 V CMC 10 · 10⁻⁶ · U\n40 Hz do 20 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 V do 220 V CMC 17 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\n20 kHz do 50 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n20 kHz do 50 kHz 700 mV do 2,2V CMC 10 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 V do 220 V CMC 27 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.07.01 Mierniki napiecia analogowe Wzorcowanie — Napiecie AC\nZakres:\n10 Hz do 20 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n10 Hz do 20 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n10 Hz do 20 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 mV do 70 mV CMC 70 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 mV do 220 mV CMC 39 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 mV do 700 mV CMC 25 · 10⁻⁶ · U\n10 Hz do 20 Hz 700 mV do 2,2V CMC 20 · 10⁻⁶ · U\n10 Hz do 20 Hz 2,2 V do 7 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 7 V do 22 V CMC 17 · 10⁻⁶ · U\n10 Hz do 20 Hz 22 V do 70 V CMC 18 · 10⁻⁶ · U\n10 Hz do 20 Hz 70 V do 220 V CMC 19 · 10⁻⁶ · U\n10 Hz do 20 Hz 220 V do 1000 V CMC 25 · 10⁻⁶ · U\n20 Hz do 40 Hz 1 mV do 2,2 mV CMC 0,52 · 10⁻³ · U\n20 Hz do 40 Hz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n20 Hz do 40 Hz 7 mV do 22 mV CMC 80 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 mV do 70 mV CMC 58 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 mV do 220 mV CMC 35 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 mV do 700 mV CMC 22 · 10⁻⁶ · U\n20 Hz do 40 Hz 700 mV do 2,2 V CMC 14 · 10⁻⁶ · U\n20 Hz do 40 Hz 2,2 V do 7 V CMC 12 · 10⁻⁶ · U\n20 Hz do 40 Hz 7 V do 22 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 22 V do 70 V CMC 16 · 10⁻⁶ · U\n20 Hz do 40 Hz 70 V do 220 V CMC 18 · 10⁻⁶ · U\n20 Hz do 40 Hz 220 V do 1000 V CMC 27 · 10⁻⁶ · U\n40 Hz do 20 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻³ · U\n40 Hz do 20 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻³ · U\n40 Hz do 20 kHz 7 mV do 22 mV CMC 65 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n40 Hz do 20 kHz 700 mV do 2,2 V CMC 10 · 10⁻⁶ · U\n40 Hz do 20 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n40 Hz do 20 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n40 Hz do 20 kHz 70 V do 220 V CMC 17 · 10⁻⁶ · U\n40 Hz do 20 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\n20 kHz do 50 kHz 1 mV do 2,2 mV CMC 0,4 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 mV do 7 mV CMC 0,16 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 mV do 70 mV CMC 35 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 mV do 220 mV CMC 25 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 mV do 700 mV CMC 12 · 10⁻⁶ · U\n20 kHz do 50 kHz 700 mV do 2,2V CMC 10 · 10⁻⁶ · U\n20 kHz do 50 kHz 2,2 V do 7 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n20 kHz do 50 kHz 22 V do 70 V CMC 15 · 10⁻⁶ · U\n20 kHz do 50 kHz 70 V do 220 V CMC 27 · 10⁻⁶ · U\n20 kHz do 50 kHz 220 V do 1000 V CMC 45 · 10⁻⁶ · U\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.07.01","search_en":"Analogue voltmeters Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 10 Hz to 20 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 20 Hz to 40 Hz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 40 Hz to 20 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz Internal procedure PP.07.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.07.01","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"10 Hz bis 20 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"10 Hz bis 20 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"10 Hz bis 20 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"22 mV to 70 mV","cmc":"70 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"70 mV to 220 mV","cmc":"39 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"220 mV to 700 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"700 mV to 2,2V","cmc":"20 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"2,2 V to 7 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"7 V to 22 V","cmc":"17 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"22 V to 70 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"70 V to 220 V","cmc":"19 · 10⁻⁶ · U"},{"name":"10 Hz bis 20 Hz","range":"220 V to 1000 V","cmc":"25 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"20 Hz bis 40 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"20 Hz bis 40 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"22 mV to 70 mV","cmc":"58 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"70 mV to 220 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"220 mV to 700 mV","cmc":"22 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"700 mV to 2,2 V","cmc":"14 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"2,2 V to 7 V","cmc":"12 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"7 V to 22 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"22 V to 70 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"70 V to 220 V","cmc":"18 · 10⁻⁶ · U"},{"name":"20 Hz bis 40 Hz","range":"220 V to 1000 V","cmc":"27 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻³ · U"},{"name":"40 Hz bis 20 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻³ · U"},{"name":"40 Hz bis 20 kHz","range":"7 mV to 22 mV","cmc":"65 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"700 mV to 2,2 V","cmc":"10 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"70 V to 220 V","cmc":"17 · 10⁻⁶ · U"},{"name":"40 Hz bis 20 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"700 mV to 2,2V","cmc":"10 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"70 V to 220 V","cmc":"27 · 10⁻⁶ · U"},{"name":"20 kHz bis 50 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"}],"reference_de":"Internes Verfahren PP.07.01","regulatory_area_de":"AC-Spannung","search_de":"Analoge Spannungsmessgeräte Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 10 Hz bis 20 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 20 Hz bis 40 Hz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 40 Hz bis 20 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz Internes Verfahren PP.07.01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Analoge Spannungsmessgeräte","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"10 Hz 至 20 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"10 Hz 至 20 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"10 Hz 至 20 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"22 mV to 70 mV","cmc":"70 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"70 mV to 220 mV","cmc":"39 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"220 mV to 700 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"700 mV to 2,2V","cmc":"20 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"2,2 V to 7 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"7 V to 22 V","cmc":"17 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"22 V to 70 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"70 V to 220 V","cmc":"19 · 10⁻⁶ · U"},{"name":"10 Hz 至 20 Hz","range":"220 V to 1000 V","cmc":"25 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"20 Hz 至 40 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"20 Hz 至 40 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"22 mV to 70 mV","cmc":"58 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"70 mV to 220 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"220 mV to 700 mV","cmc":"22 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"700 mV to 2,2 V","cmc":"14 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"2,2 V to 7 V","cmc":"12 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"7 V to 22 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"22 V to 70 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"70 V to 220 V","cmc":"18 · 10⁻⁶ · U"},{"name":"20 Hz 至 40 Hz","range":"220 V to 1000 V","cmc":"27 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻³ · U"},{"name":"40 Hz 至 20 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻³ · U"},{"name":"40 Hz 至 20 kHz","range":"7 mV to 22 mV","cmc":"65 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"700 mV to 2,2 V","cmc":"10 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"70 V to 220 V","cmc":"17 · 10⁻⁶ · U"},{"name":"40 Hz 至 20 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"700 mV to 2,2V","cmc":"10 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"70 V to 220 V","cmc":"27 · 10⁻⁶ · U"},{"name":"20 kHz 至 50 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"}],"reference_zh":"内部程序 PP.07.01","regulatory_area_zh":"交流电压","search_zh":"模拟电压表 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 10 Hz 至 20 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 20 Hz 至 40 Hz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 40 Hz 至 20 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 内部程序 PP.07.01","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"模拟电压表","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"10 Hz až 20 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"10 Hz až 20 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"10 Hz až 20 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"22 mV to 70 mV","cmc":"70 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"70 mV to 220 mV","cmc":"39 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"220 mV to 700 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"700 mV to 2,2V","cmc":"20 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"2,2 V to 7 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"7 V to 22 V","cmc":"17 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"22 V to 70 V","cmc":"18 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"70 V to 220 V","cmc":"19 · 10⁻⁶ · U"},{"name":"10 Hz až 20 Hz","range":"220 V to 1000 V","cmc":"25 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"1 mV to 2,2 mV","cmc":"0,52 · 10⁻³ · U"},{"name":"20 Hz až 40 Hz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"20 Hz až 40 Hz","range":"7 mV to 22 mV","cmc":"80 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"22 mV to 70 mV","cmc":"58 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"70 mV to 220 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"220 mV to 700 mV","cmc":"22 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"700 mV to 2,2 V","cmc":"14 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"2,2 V to 7 V","cmc":"12 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"7 V to 22 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"22 V to 70 V","cmc":"16 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"70 V to 220 V","cmc":"18 · 10⁻⁶ · U"},{"name":"20 Hz až 40 Hz","range":"220 V to 1000 V","cmc":"27 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻³ · U"},{"name":"40 Hz až 20 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻³ · U"},{"name":"40 Hz až 20 kHz","range":"7 mV to 22 mV","cmc":"65 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"700 mV to 2,2 V","cmc":"10 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"70 V to 220 V","cmc":"17 · 10⁻⁶ · U"},{"name":"40 Hz až 20 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"1 mV to 2,2 mV","cmc":"0,4 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"2,2 mV to 7 mV","cmc":"0,16 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"22 mV to 70 mV","cmc":"35 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"70 mV to 220 mV","cmc":"25 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"220 mV to 700 mV","cmc":"12 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"700 mV to 2,2V","cmc":"10 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"2,2 V to 7 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"22 V to 70 V","cmc":"15 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"70 V to 220 V","cmc":"27 · 10⁻⁶ · U"},{"name":"20 kHz až 50 kHz","range":"220 V to 1000 V","cmc":"45 · 10⁻⁶ · U"}],"reference_cs":"Vnitřní postup PP.07.01","regulatory_area_cs":"Napětí AC","search_cs":"Analogové měřiče napětí Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 10 Hz až 20 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 20 Hz až 40 Hz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 40 Hz až 20 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz Vnitřní postup PP.07.01","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analogové měřiče napětí"},{"_id":"12607bab14375320c5c57172","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Kalibratory\nMierniki napięcia cyfrowe\nMultimetry","test_object_en":"Calibrators\nDigital voltmeters\nMultimeters","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"50 kHz do 100 kHz","range":"1 mV do 2,2 mV","cmc":"0,41 · 10⁻³ · U"},{"name":"50 kHz do 100 kHz","range":"2,2 mV do 7 mV","cmc":"0,2 · 10⁻³ · U"},{"name":"50 kHz do 100 kHz","range":"7 mV do 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"22 mV do 70 mV","cmc":"45 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"70 mV do 220 mV","cmc":"28 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"220 mV do 700 mV","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"700 mV do 2,2V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"2,2 V do 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"7 V do 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"22 V do 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"70 V do 220 V","cmc":"32 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"220 V do 1000 V","cmc":"65 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"1 mV do 2,2 mV","cmc":"0,46 · 10⁻³ · U"},{"name":"100 kHz do 300 kHz","range":"2,2 mV do 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"100 kHz do 300 kHz","range":"7 mV do 22 mV","cmc":"95 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"22 mV do 70 mV","cmc":"55 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"70 mV do 220 mV","cmc":"42 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"220 mV do 700 mV","cmc":"14 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"700 mV do 2,2 V","cmc":"11 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"2,2 V do 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"7 V do 22 V","cmc":"25 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"22 V do 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"1 mV do 2,2 mV","cmc":"0,55 · 10⁻³ · U"},{"name":"300 kHz do 500 kHz","range":"2,2 mV do 7 mV","cmc":"0,33 · 10⁻³ · U"},{"name":"300 kHz do 500 kHz","range":"7 mV do 22 mV","cmc":"0,19 · 10⁻³ · U"},{"name":"300 kHz do 500 kHz","range":"22 mV do 70 mV","cmc":"0,11 · 10⁻³ · U"},{"name":"300 kHz do 500 kHz","range":"70 mV do 220 mV","cmc":"85 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"220 mV do 700 mV","cmc":"27 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"700 mV do 2,2 V","cmc":"22 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"2,2 V do 7 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"7 V do 22 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"22 V do 70 V","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz do 1 MHz","range":"1 mV do 2,2 mV","cmc":"0,60 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"2,2 mV do 7 mV","cmc":"0,45 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"7 mV do 22 mV","cmc":"0,21 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"22 mV do 70 mV","cmc":"0,23 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"70 mV do 220 mV","cmc":"0,1 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"220 mV do 700 mV","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz do 1 MHz","range":"700 mV do 2,2 V","cmc":"68 · 10⁻⁶ · U"},{"name":"500 kHz do 1 MHz","range":"2,2 V do 7 V","cmc":"95 · 10⁻⁶ · U"},{"name":"500 kHz do 1 MHz","range":"7 V do 22 V","cmc":"0,11 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"22 V do 70 V","cmc":"0,13 · 10⁻³ · U"}],"parameters_en":[{"name":"50 kHz to 100 kHz","range":"1 mV to 2,2 mV","cmc":"0,41 · 10⁻³ · U"},{"name":"50 kHz to 100 kHz","range":"2,2 mV to 7 mV","cmc":"0,2 · 10⁻³ · U"},{"name":"50 kHz to 100 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"22 mV to 70 mV","cmc":"45 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"70 mV to 220 mV","cmc":"28 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"220 mV to 700 mV","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"700 mV to 2,2V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"70 V to 220 V","cmc":"32 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"220 V to 1000 V","cmc":"65 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"1 mV to 2,2 mV","cmc":"0,46 · 10⁻³ · U"},{"name":"100 kHz to 300 kHz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"100 kHz to 300 kHz","range":"7 mV to 22 mV","cmc":"95 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"22 mV to 70 mV","cmc":"55 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"70 mV to 220 mV","cmc":"42 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"220 mV to 700 mV","cmc":"14 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"700 mV to 2,2 V","cmc":"11 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"7 V to 22 V","cmc":"25 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"1 mV to 2,2 mV","cmc":"0,55 · 10⁻³ · U"},{"name":"300 kHz to 500 kHz","range":"2,2 mV to 7 mV","cmc":"0,33 · 10⁻³ · U"},{"name":"300 kHz to 500 kHz","range":"7 mV to 22 mV","cmc":"0,19 · 10⁻³ · U"},{"name":"300 kHz to 500 kHz","range":"22 mV to 70 mV","cmc":"0,11 · 10⁻³ · U"},{"name":"300 kHz to 500 kHz","range":"70 mV to 220 mV","cmc":"85 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"220 mV to 700 mV","cmc":"27 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"700 mV to 2,2 V","cmc":"22 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"2,2 V to 7 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"7 V to 22 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"22 V to 70 V","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz to 1 MHz","range":"1 mV to 2,2 mV","cmc":"0,60 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"2,2 mV to 7 mV","cmc":"0,45 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"7 mV to 22 mV","cmc":"0,21 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"22 mV to 70 mV","cmc":"0,23 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"70 mV to 220 mV","cmc":"0,1 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"220 mV to 700 mV","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz to 1 MHz","range":"700 mV to 2,2 V","cmc":"68 · 10⁻⁶ · U"},{"name":"500 kHz to 1 MHz","range":"2,2 V to 7 V","cmc":"95 · 10⁻⁶ · U"},{"name":"500 kHz to 1 MHz","range":"7 V to 22 V","cmc":"0,11 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"22 V to 70 V","cmc":"0,13 · 10⁻³ · U"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n50 kHz do 100 kHz 1 mV do 2,2 mV CMC 0,41 · 10⁻³ · U\n50 kHz do 100 kHz 2,2 mV do 7 mV CMC 0,2 · 10⁻³ · U\n50 kHz do 100 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 mV do 70 mV CMC 45 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 mV do 220 mV CMC 28 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 mV do 700 mV CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 700 mV do 2,2V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 V do 220 V CMC 32 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 V do 1000 V CMC 65 · 10⁻⁶ · U\n100 kHz do 300 kHz 1 mV do 2,2 mV CMC 0,46 · 10⁻³ · U\n100 kHz do 300 kHz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n100 kHz do 300 kHz 7 mV do 22 mV CMC 95 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 mV do 70 mV CMC 55 · 10⁻⁶ · U\n100 kHz do 300 kHz 70 mV do 220 mV CMC 42 · 10⁻⁶ · U\n100 kHz do 300 kHz 220 mV do 700 mV CMC 14 · 10⁻⁶ · U\n100 kHz do 300 kHz 700 mV do 2,2 V CMC 11 · 10⁻⁶ · U\n100 kHz do 300 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n100 kHz do 300 kHz 7 V do 22 V CMC 25 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n300 kHz do 500 kHz 1 mV do 2,2 mV CMC 0,55 · 10⁻³ · U\n300 kHz do 500 kHz 2,2 mV do 7 mV CMC 0,33 · 10⁻³ · U\n300 kHz do 500 kHz 7 mV do 22 mV CMC 0,19 · 10⁻³ · U\n300 kHz do 500 kHz 22 mV do 70 mV CMC 0,11 · 10⁻³ · U\n300 kHz do 500 kHz 70 mV do 220 mV CMC 85 · 10⁻⁶ · U\n300 kHz do 500 kHz 220 mV do 700 mV CMC 27 · 10⁻⁶ · U\n300 kHz do 500 kHz 700 mV do 2,2 V CMC 22 · 10⁻⁶ · U\n300 kHz do 500 kHz 2,2 V do 7 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 7 V do 22 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 22 V do 70 V CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 1 mV do 2,2 mV CMC 0,60 · 10⁻³ · U\n500 kHz do 1 MHz 2,2 mV do 7 mV CMC 0,45 · 10⁻³ · U\n500 kHz do 1 MHz 7 mV do 22 mV CMC 0,21 · 10⁻³ · U\n500 kHz do 1 MHz 22 mV do 70 mV CMC 0,23 · 10⁻³ · U\n500 kHz do 1 MHz 70 mV do 220 mV CMC 0,1 · 10⁻³ · U\n500 kHz do 1 MHz 220 mV do 700 mV CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 700 mV do 2,2 V CMC 68 · 10⁻⁶ · U\n500 kHz do 1 MHz 2,2 V do 7 V CMC 95 · 10⁻⁶ · U\n500 kHz do 1 MHz 7 V do 22 V CMC 0,11 · 10⁻³ · U\n500 kHz do 1 MHz 22 V do 70 V CMC 0,13 · 10⁻³ · U\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Kalibratory\nMierniki napięcia cyfrowe\nMultimetry Wzorcowanie — Napięcie AC\nZakres:\n50 kHz do 100 kHz 1 mV do 2,2 mV CMC 0,41 · 10⁻³ · U\n50 kHz do 100 kHz 2,2 mV do 7 mV CMC 0,2 · 10⁻³ · U\n50 kHz do 100 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 mV do 70 mV CMC 45 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 mV do 220 mV CMC 28 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 mV do 700 mV CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 700 mV do 2,2V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 V do 220 V CMC 32 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 V do 1000 V CMC 65 · 10⁻⁶ · U\n100 kHz do 300 kHz 1 mV do 2,2 mV CMC 0,46 · 10⁻³ · U\n100 kHz do 300 kHz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n100 kHz do 300 kHz 7 mV do 22 mV CMC 95 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 mV do 70 mV CMC 55 · 10⁻⁶ · U\n100 kHz do 300 kHz 70 mV do 220 mV CMC 42 · 10⁻⁶ · U\n100 kHz do 300 kHz 220 mV do 700 mV CMC 14 · 10⁻⁶ · U\n100 kHz do 300 kHz 700 mV do 2,2 V CMC 11 · 10⁻⁶ · U\n100 kHz do 300 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n100 kHz do 300 kHz 7 V do 22 V CMC 25 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n300 kHz do 500 kHz 1 mV do 2,2 mV CMC 0,55 · 10⁻³ · U\n300 kHz do 500 kHz 2,2 mV do 7 mV CMC 0,33 · 10⁻³ · U\n300 kHz do 500 kHz 7 mV do 22 mV CMC 0,19 · 10⁻³ · U\n300 kHz do 500 kHz 22 mV do 70 mV CMC 0,11 · 10⁻³ · U\n300 kHz do 500 kHz 70 mV do 220 mV CMC 85 · 10⁻⁶ · U\n300 kHz do 500 kHz 220 mV do 700 mV CMC 27 · 10⁻⁶ · U\n300 kHz do 500 kHz 700 mV do 2,2 V CMC 22 · 10⁻⁶ · U\n300 kHz do 500 kHz 2,2 V do 7 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 7 V do 22 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 22 V do 70 V CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 1 mV do 2,2 mV CMC 0,60 · 10⁻³ · U\n500 kHz do 1 MHz 2,2 mV do 7 mV CMC 0,45 · 10⁻³ · U\n500 kHz do 1 MHz 7 mV do 22 mV CMC 0,21 · 10⁻³ · U\n500 kHz do 1 MHz 22 mV do 70 mV CMC 0,23 · 10⁻³ · U\n500 kHz do 1 MHz 70 mV do 220 mV CMC 0,1 · 10⁻³ · U\n500 kHz do 1 MHz 220 mV do 700 mV CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 700 mV do 2,2 V CMC 68 · 10⁻⁶ · U\n500 kHz do 1 MHz 2,2 V do 7 V CMC 95 · 10⁻⁶ · U\n500 kHz do 1 MHz 7 V do 22 V CMC 0,11 · 10⁻³ · U\n500 kHz do 1 MHz 22 V do 70 V CMC 0,13 · 10⁻³ · U\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-15 v.3.0 Kalibratory\nMierniki napiecia cyfrowe\nMultimetry Wzorcowanie — Napiecie AC\nZakres:\n50 kHz do 100 kHz 1 mV do 2,2 mV CMC 0,41 · 10⁻³ · U\n50 kHz do 100 kHz 2,2 mV do 7 mV CMC 0,2 · 10⁻³ · U\n50 kHz do 100 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 mV do 70 mV CMC 45 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 mV do 220 mV CMC 28 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 mV do 700 mV CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 700 mV do 2,2V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 V do 220 V CMC 32 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 V do 1000 V CMC 65 · 10⁻⁶ · U\n100 kHz do 300 kHz 1 mV do 2,2 mV CMC 0,46 · 10⁻³ · U\n100 kHz do 300 kHz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n100 kHz do 300 kHz 7 mV do 22 mV CMC 95 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 mV do 70 mV CMC 55 · 10⁻⁶ · U\n100 kHz do 300 kHz 70 mV do 220 mV CMC 42 · 10⁻⁶ · U\n100 kHz do 300 kHz 220 mV do 700 mV CMC 14 · 10⁻⁶ · U\n100 kHz do 300 kHz 700 mV do 2,2 V CMC 11 · 10⁻⁶ · U\n100 kHz do 300 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n100 kHz do 300 kHz 7 V do 22 V CMC 25 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n300 kHz do 500 kHz 1 mV do 2,2 mV CMC 0,55 · 10⁻³ · U\n300 kHz do 500 kHz 2,2 mV do 7 mV CMC 0,33 · 10⁻³ · U\n300 kHz do 500 kHz 7 mV do 22 mV CMC 0,19 · 10⁻³ · U\n300 kHz do 500 kHz 22 mV do 70 mV CMC 0,11 · 10⁻³ · U\n300 kHz do 500 kHz 70 mV do 220 mV CMC 85 · 10⁻⁶ · U\n300 kHz do 500 kHz 220 mV do 700 mV CMC 27 · 10⁻⁶ · U\n300 kHz do 500 kHz 700 mV do 2,2 V CMC 22 · 10⁻⁶ · U\n300 kHz do 500 kHz 2,2 V do 7 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 7 V do 22 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 22 V do 70 V CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 1 mV do 2,2 mV CMC 0,60 · 10⁻³ · U\n500 kHz do 1 MHz 2,2 mV do 7 mV CMC 0,45 · 10⁻³ · U\n500 kHz do 1 MHz 7 mV do 22 mV CMC 0,21 · 10⁻³ · U\n500 kHz do 1 MHz 22 mV do 70 mV CMC 0,23 · 10⁻³ · U\n500 kHz do 1 MHz 70 mV do 220 mV CMC 0,1 · 10⁻³ · U\n500 kHz do 1 MHz 220 mV do 700 mV CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 700 mV do 2,2 V CMC 68 · 10⁻⁶ · U\n500 kHz do 1 MHz 2,2 V do 7 V CMC 95 · 10⁻⁶ · U\n500 kHz do 1 MHz 7 V do 22 V CMC 0,11 · 10⁻³ · U\n500 kHz do 1 MHz 22 V do 70 V CMC 0,13 · 10⁻³ · U\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-15 v.3.0","search_en":"Calibrators Digital voltmeters Multimeters Calibration — AC voltage Direct and indirect method; At permanent location (S) and outside of it (P) AC voltage Direct and indirect method At permanent location (S) and outside of it (P) 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"50 kHz bis 100 kHz","range":"1 mV to 2,2 mV","cmc":"0,41 · 10⁻³ · U"},{"name":"50 kHz bis 100 kHz","range":"2,2 mV to 7 mV","cmc":"0,2 · 10⁻³ · U"},{"name":"50 kHz bis 100 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"22 mV to 70 mV","cmc":"45 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"70 mV to 220 mV","cmc":"28 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"220 mV to 700 mV","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"700 mV to 2,2V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"70 V to 220 V","cmc":"32 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"220 V to 1000 V","cmc":"65 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"1 mV to 2,2 mV","cmc":"0,46 · 10⁻³ · U"},{"name":"100 kHz bis 300 kHz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"100 kHz bis 300 kHz","range":"7 mV to 22 mV","cmc":"95 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"22 mV to 70 mV","cmc":"55 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"70 mV to 220 mV","cmc":"42 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"220 mV to 700 mV","cmc":"14 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"700 mV to 2,2 V","cmc":"11 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"7 V to 22 V","cmc":"25 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"1 mV to 2,2 mV","cmc":"0,55 · 10⁻³ · U"},{"name":"300 kHz bis 500 kHz","range":"2,2 mV to 7 mV","cmc":"0,33 · 10⁻³ · U"},{"name":"300 kHz bis 500 kHz","range":"7 mV to 22 mV","cmc":"0,19 · 10⁻³ · U"},{"name":"300 kHz bis 500 kHz","range":"22 mV to 70 mV","cmc":"0,11 · 10⁻³ · U"},{"name":"300 kHz bis 500 kHz","range":"70 mV to 220 mV","cmc":"85 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"220 mV to 700 mV","cmc":"27 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"700 mV to 2,2 V","cmc":"22 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"2,2 V to 7 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"7 V to 22 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"22 V to 70 V","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz bis 1 MHz","range":"1 mV to 2,2 mV","cmc":"0,60 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"2,2 mV to 7 mV","cmc":"0,45 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"7 mV to 22 mV","cmc":"0,21 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"22 mV to 70 mV","cmc":"0,23 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"70 mV to 220 mV","cmc":"0,1 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"220 mV to 700 mV","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz bis 1 MHz","range":"700 mV to 2,2 V","cmc":"68 · 10⁻⁶ · U"},{"name":"500 kHz bis 1 MHz","range":"2,2 V to 7 V","cmc":"95 · 10⁻⁶ · U"},{"name":"500 kHz bis 1 MHz","range":"7 V to 22 V","cmc":"0,11 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"22 V to 70 V","cmc":"0,13 · 10⁻³ · U"}],"regulatory_area_de":"AC-Spannung","search_de":"Kalibratoren Digitale Spannungsmessgeräte Multimeter Kalibrierung — Wechselspannung Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nDigitale Spannungsmessgeräte\nMultimeter","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"50 kHz 至 100 kHz","range":"1 mV to 2,2 mV","cmc":"0,41 · 10⁻³ · U"},{"name":"50 kHz 至 100 kHz","range":"2,2 mV to 7 mV","cmc":"0,2 · 10⁻³ · U"},{"name":"50 kHz 至 100 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"22 mV to 70 mV","cmc":"45 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"70 mV to 220 mV","cmc":"28 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"220 mV to 700 mV","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"700 mV to 2,2V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"70 V to 220 V","cmc":"32 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"220 V to 1000 V","cmc":"65 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"1 mV to 2,2 mV","cmc":"0,46 · 10⁻³ · U"},{"name":"100 kHz 至 300 kHz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"100 kHz 至 300 kHz","range":"7 mV to 22 mV","cmc":"95 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"22 mV to 70 mV","cmc":"55 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"70 mV to 220 mV","cmc":"42 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"220 mV to 700 mV","cmc":"14 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"700 mV to 2,2 V","cmc":"11 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"7 V to 22 V","cmc":"25 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"1 mV to 2,2 mV","cmc":"0,55 · 10⁻³ · U"},{"name":"300 kHz 至 500 kHz","range":"2,2 mV to 7 mV","cmc":"0,33 · 10⁻³ · U"},{"name":"300 kHz 至 500 kHz","range":"7 mV to 22 mV","cmc":"0,19 · 10⁻³ · U"},{"name":"300 kHz 至 500 kHz","range":"22 mV to 70 mV","cmc":"0,11 · 10⁻³ · U"},{"name":"300 kHz 至 500 kHz","range":"70 mV to 220 mV","cmc":"85 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"220 mV to 700 mV","cmc":"27 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"700 mV to 2,2 V","cmc":"22 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"2,2 V to 7 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"7 V to 22 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"22 V to 70 V","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz 至 1 MHz","range":"1 mV to 2,2 mV","cmc":"0,60 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"2,2 mV to 7 mV","cmc":"0,45 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"7 mV to 22 mV","cmc":"0,21 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"22 mV to 70 mV","cmc":"0,23 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"70 mV to 220 mV","cmc":"0,1 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"220 mV to 700 mV","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz 至 1 MHz","range":"700 mV to 2,2 V","cmc":"68 · 10⁻⁶ · U"},{"name":"500 kHz 至 1 MHz","range":"2,2 V to 7 V","cmc":"95 · 10⁻⁶ · U"},{"name":"500 kHz 至 1 MHz","range":"7 V to 22 V","cmc":"0,11 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"22 V to 70 V","cmc":"0,13 · 10⁻³ · U"}],"regulatory_area_zh":"交流电压","search_zh":"校准器 数字电压表 万用表 校准 — 交流电压 直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n数字电压表\n万用表","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"50 kHz až 100 kHz","range":"1 mV to 2,2 mV","cmc":"0,41 · 10⁻³ · U"},{"name":"50 kHz až 100 kHz","range":"2,2 mV to 7 mV","cmc":"0,2 · 10⁻³ · U"},{"name":"50 kHz až 100 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"22 mV to 70 mV","cmc":"45 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"70 mV to 220 mV","cmc":"28 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"220 mV to 700 mV","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"700 mV to 2,2V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"70 V to 220 V","cmc":"32 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"220 V to 1000 V","cmc":"65 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"1 mV to 2,2 mV","cmc":"0,46 · 10⁻³ · U"},{"name":"100 kHz až 300 kHz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"100 kHz až 300 kHz","range":"7 mV to 22 mV","cmc":"95 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"22 mV to 70 mV","cmc":"55 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"70 mV to 220 mV","cmc":"42 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"220 mV to 700 mV","cmc":"14 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"700 mV to 2,2 V","cmc":"11 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"7 V to 22 V","cmc":"25 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"1 mV to 2,2 mV","cmc":"0,55 · 10⁻³ · U"},{"name":"300 kHz až 500 kHz","range":"2,2 mV to 7 mV","cmc":"0,33 · 10⁻³ · U"},{"name":"300 kHz až 500 kHz","range":"7 mV to 22 mV","cmc":"0,19 · 10⁻³ · U"},{"name":"300 kHz až 500 kHz","range":"22 mV to 70 mV","cmc":"0,11 · 10⁻³ · U"},{"name":"300 kHz až 500 kHz","range":"70 mV to 220 mV","cmc":"85 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"220 mV to 700 mV","cmc":"27 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"700 mV to 2,2 V","cmc":"22 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"2,2 V to 7 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"7 V to 22 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"22 V to 70 V","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz až 1 MHz","range":"1 mV to 2,2 mV","cmc":"0,60 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"2,2 mV to 7 mV","cmc":"0,45 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"7 mV to 22 mV","cmc":"0,21 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"22 mV to 70 mV","cmc":"0,23 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"70 mV to 220 mV","cmc":"0,1 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"220 mV to 700 mV","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz až 1 MHz","range":"700 mV to 2,2 V","cmc":"68 · 10⁻⁶ · U"},{"name":"500 kHz až 1 MHz","range":"2,2 V to 7 V","cmc":"95 · 10⁻⁶ · U"},{"name":"500 kHz až 1 MHz","range":"7 V to 22 V","cmc":"0,11 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"22 V to 70 V","cmc":"0,13 · 10⁻³ · U"}],"regulatory_area_cs":"Napětí AC","search_cs":"Kalibrátory Digitální měřiče napětí Multimetry Kalibrace — Napětí AC Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Napětí AC Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nDigitální měřiče napětí\nMultimetry"},{"_id":"84053d3a8b27a357da67ac91","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Mierniki napięcia analogowe","test_object_en":"Analogue voltmeters","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"50 kHz do 100 kHz","range":"1 mV do 2,2 mV","cmc":"0,41 · 10⁻³ · U"},{"name":"50 kHz do 100 kHz","range":"2,2 mV do 7 mV","cmc":"0,2 · 10⁻³ · U"},{"name":"50 kHz do 100 kHz","range":"7 mV do 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"22 mV do 70 mV","cmc":"45 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"70 mV do 220 mV","cmc":"28 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"220 mV do 700 mV","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"700 mV do 2,2V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"2,2 V do 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"7 V do 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"22 V do 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"70 V do 220 V","cmc":"32 · 10⁻⁶ · U"},{"name":"50 kHz do 100 kHz","range":"220 V do 1000 V","cmc":"65 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"1 mV do 2,2 mV","cmc":"0,46 · 10⁻³ · U"},{"name":"100 kHz do 300 kHz","range":"2,2 mV do 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"100 kHz do 300 kHz","range":"7 mV do 22 mV","cmc":"95 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"22 mV do 70 mV","cmc":"55 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"70 mV do 220 mV","cmc":"42 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"220 mV do 700 mV","cmc":"14 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"700 mV do 2,2 V","cmc":"11 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"2,2 V do 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"7 V do 22 V","cmc":"25 · 10⁻⁶ · U"},{"name":"100 kHz do 300 kHz","range":"22 V do 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"1 mV do 2,2 mV","cmc":"0,55 · 10⁻³ · U"},{"name":"300 kHz do 500 kHz","range":"2,2 mV do 7 mV","cmc":"0,33 · 10⁻³ · U"},{"name":"300 kHz do 500 kHz","range":"7 mV do 22 mV","cmc":"0,19 · 10⁻³ · U"},{"name":"300 kHz do 500 kHz","range":"22 mV do 70 mV","cmc":"0,11 · 10⁻³ · U"},{"name":"300 kHz do 500 kHz","range":"70 mV do 220 mV","cmc":"85 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"220 mV do 700 mV","cmc":"27 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"700 mV do 2,2 V","cmc":"22 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"2,2 V do 7 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"7 V do 22 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz do 500 kHz","range":"22 V do 70 V","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz do 1 MHz","range":"1 mV do 2,2 mV","cmc":"0,60 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"2,2 mV do 7 mV","cmc":"0,45 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"7 mV do 22 mV","cmc":"0,21 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"22 mV do 70 mV","cmc":"0,23 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"70 mV do 220 mV","cmc":"0,1 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"220 mV do 700 mV","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz do 1 MHz","range":"700 mV do 2,2 V","cmc":"68 · 10⁻⁶ · U"},{"name":"500 kHz do 1 MHz","range":"2,2 V do 7 V","cmc":"95 · 10⁻⁶ · U"},{"name":"500 kHz do 1 MHz","range":"7 V do 22 V","cmc":"0,11 · 10⁻³ · U"},{"name":"500 kHz do 1 MHz","range":"22 V do 70 V","cmc":"0,13 · 10⁻³ · U"}],"parameters_en":[{"name":"50 kHz to 100 kHz","range":"1 mV to 2,2 mV","cmc":"0,41 · 10⁻³ · U"},{"name":"50 kHz to 100 kHz","range":"2,2 mV to 7 mV","cmc":"0,2 · 10⁻³ · U"},{"name":"50 kHz to 100 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"22 mV to 70 mV","cmc":"45 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"70 mV to 220 mV","cmc":"28 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"220 mV to 700 mV","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"700 mV to 2,2V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"70 V to 220 V","cmc":"32 · 10⁻⁶ · U"},{"name":"50 kHz to 100 kHz","range":"220 V to 1000 V","cmc":"65 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"1 mV to 2,2 mV","cmc":"0,46 · 10⁻³ · U"},{"name":"100 kHz to 300 kHz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"100 kHz to 300 kHz","range":"7 mV to 22 mV","cmc":"95 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"22 mV to 70 mV","cmc":"55 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"70 mV to 220 mV","cmc":"42 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"220 mV to 700 mV","cmc":"14 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"700 mV to 2,2 V","cmc":"11 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"7 V to 22 V","cmc":"25 · 10⁻⁶ · U"},{"name":"100 kHz to 300 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"1 mV to 2,2 mV","cmc":"0,55 · 10⁻³ · U"},{"name":"300 kHz to 500 kHz","range":"2,2 mV to 7 mV","cmc":"0,33 · 10⁻³ · U"},{"name":"300 kHz to 500 kHz","range":"7 mV to 22 mV","cmc":"0,19 · 10⁻³ · U"},{"name":"300 kHz to 500 kHz","range":"22 mV to 70 mV","cmc":"0,11 · 10⁻³ · U"},{"name":"300 kHz to 500 kHz","range":"70 mV to 220 mV","cmc":"85 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"220 mV to 700 mV","cmc":"27 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"700 mV to 2,2 V","cmc":"22 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"2,2 V to 7 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"7 V to 22 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz to 500 kHz","range":"22 V to 70 V","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz to 1 MHz","range":"1 mV to 2,2 mV","cmc":"0,60 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"2,2 mV to 7 mV","cmc":"0,45 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"7 mV to 22 mV","cmc":"0,21 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"22 mV to 70 mV","cmc":"0,23 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"70 mV to 220 mV","cmc":"0,1 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"220 mV to 700 mV","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz to 1 MHz","range":"700 mV to 2,2 V","cmc":"68 · 10⁻⁶ · U"},{"name":"500 kHz to 1 MHz","range":"2,2 V to 7 V","cmc":"95 · 10⁻⁶ · U"},{"name":"500 kHz to 1 MHz","range":"7 V to 22 V","cmc":"0,11 · 10⁻³ · U"},{"name":"500 kHz to 1 MHz","range":"22 V to 70 V","cmc":"0,13 · 10⁻³ · U"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n50 kHz do 100 kHz 1 mV do 2,2 mV CMC 0,41 · 10⁻³ · U\n50 kHz do 100 kHz 2,2 mV do 7 mV CMC 0,2 · 10⁻³ · U\n50 kHz do 100 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 mV do 70 mV CMC 45 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 mV do 220 mV CMC 28 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 mV do 700 mV CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 700 mV do 2,2V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 V do 220 V CMC 32 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 V do 1000 V CMC 65 · 10⁻⁶ · U\n100 kHz do 300 kHz 1 mV do 2,2 mV CMC 0,46 · 10⁻³ · U\n100 kHz do 300 kHz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n100 kHz do 300 kHz 7 mV do 22 mV CMC 95 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 mV do 70 mV CMC 55 · 10⁻⁶ · U\n100 kHz do 300 kHz 70 mV do 220 mV CMC 42 · 10⁻⁶ · U\n100 kHz do 300 kHz 220 mV do 700 mV CMC 14 · 10⁻⁶ · U\n100 kHz do 300 kHz 700 mV do 2,2 V CMC 11 · 10⁻⁶ · U\n100 kHz do 300 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n100 kHz do 300 kHz 7 V do 22 V CMC 25 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n300 kHz do 500 kHz 1 mV do 2,2 mV CMC 0,55 · 10⁻³ · U\n300 kHz do 500 kHz 2,2 mV do 7 mV CMC 0,33 · 10⁻³ · U\n300 kHz do 500 kHz 7 mV do 22 mV CMC 0,19 · 10⁻³ · U\n300 kHz do 500 kHz 22 mV do 70 mV CMC 0,11 · 10⁻³ · U\n300 kHz do 500 kHz 70 mV do 220 mV CMC 85 · 10⁻⁶ · U\n300 kHz do 500 kHz 220 mV do 700 mV CMC 27 · 10⁻⁶ · U\n300 kHz do 500 kHz 700 mV do 2,2 V CMC 22 · 10⁻⁶ · U\n300 kHz do 500 kHz 2,2 V do 7 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 7 V do 22 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 22 V do 70 V CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 1 mV do 2,2 mV CMC 0,60 · 10⁻³ · U\n500 kHz do 1 MHz 2,2 mV do 7 mV CMC 0,45 · 10⁻³ · U\n500 kHz do 1 MHz 7 mV do 22 mV CMC 0,21 · 10⁻³ · U\n500 kHz do 1 MHz 22 mV do 70 mV CMC 0,23 · 10⁻³ · U\n500 kHz do 1 MHz 70 mV do 220 mV CMC 0,1 · 10⁻³ · U\n500 kHz do 1 MHz 220 mV do 700 mV CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 700 mV do 2,2 V CMC 68 · 10⁻⁶ · U\n500 kHz do 1 MHz 2,2 V do 7 V CMC 95 · 10⁻⁶ · U\n500 kHz do 1 MHz 7 V do 22 V CMC 0,11 · 10⁻³ · U\n500 kHz do 1 MHz 22 V do 70 V CMC 0,13 · 10⁻³ · U\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.07.01","norm_bases":["PP.07.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Mierniki napięcia analogowe Wzorcowanie — Napięcie AC\nZakres:\n50 kHz do 100 kHz 1 mV do 2,2 mV CMC 0,41 · 10⁻³ · U\n50 kHz do 100 kHz 2,2 mV do 7 mV CMC 0,2 · 10⁻³ · U\n50 kHz do 100 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 mV do 70 mV CMC 45 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 mV do 220 mV CMC 28 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 mV do 700 mV CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 700 mV do 2,2V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 V do 220 V CMC 32 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 V do 1000 V CMC 65 · 10⁻⁶ · U\n100 kHz do 300 kHz 1 mV do 2,2 mV CMC 0,46 · 10⁻³ · U\n100 kHz do 300 kHz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n100 kHz do 300 kHz 7 mV do 22 mV CMC 95 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 mV do 70 mV CMC 55 · 10⁻⁶ · U\n100 kHz do 300 kHz 70 mV do 220 mV CMC 42 · 10⁻⁶ · U\n100 kHz do 300 kHz 220 mV do 700 mV CMC 14 · 10⁻⁶ · U\n100 kHz do 300 kHz 700 mV do 2,2 V CMC 11 · 10⁻⁶ · U\n100 kHz do 300 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n100 kHz do 300 kHz 7 V do 22 V CMC 25 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n300 kHz do 500 kHz 1 mV do 2,2 mV CMC 0,55 · 10⁻³ · U\n300 kHz do 500 kHz 2,2 mV do 7 mV CMC 0,33 · 10⁻³ · U\n300 kHz do 500 kHz 7 mV do 22 mV CMC 0,19 · 10⁻³ · U\n300 kHz do 500 kHz 22 mV do 70 mV CMC 0,11 · 10⁻³ · U\n300 kHz do 500 kHz 70 mV do 220 mV CMC 85 · 10⁻⁶ · U\n300 kHz do 500 kHz 220 mV do 700 mV CMC 27 · 10⁻⁶ · U\n300 kHz do 500 kHz 700 mV do 2,2 V CMC 22 · 10⁻⁶ · U\n300 kHz do 500 kHz 2,2 V do 7 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 7 V do 22 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 22 V do 70 V CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 1 mV do 2,2 mV CMC 0,60 · 10⁻³ · U\n500 kHz do 1 MHz 2,2 mV do 7 mV CMC 0,45 · 10⁻³ · U\n500 kHz do 1 MHz 7 mV do 22 mV CMC 0,21 · 10⁻³ · U\n500 kHz do 1 MHz 22 mV do 70 mV CMC 0,23 · 10⁻³ · U\n500 kHz do 1 MHz 70 mV do 220 mV CMC 0,1 · 10⁻³ · U\n500 kHz do 1 MHz 220 mV do 700 mV CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 700 mV do 2,2 V CMC 68 · 10⁻⁶ · U\n500 kHz do 1 MHz 2,2 V do 7 V CMC 95 · 10⁻⁶ · U\n500 kHz do 1 MHz 7 V do 22 V CMC 0,11 · 10⁻³ · U\n500 kHz do 1 MHz 22 V do 70 V CMC 0,13 · 10⁻³ · U\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.07.01 Mierniki napiecia analogowe Wzorcowanie — Napiecie AC\nZakres:\n50 kHz do 100 kHz 1 mV do 2,2 mV CMC 0,41 · 10⁻³ · U\n50 kHz do 100 kHz 2,2 mV do 7 mV CMC 0,2 · 10⁻³ · U\n50 kHz do 100 kHz 7 mV do 22 mV CMC 75 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 mV do 70 mV CMC 45 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 mV do 220 mV CMC 28 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 mV do 700 mV CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 700 mV do 2,2V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n50 kHz do 100 kHz 7 V do 22 V CMC 11 · 10⁻⁶ · U\n50 kHz do 100 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n50 kHz do 100 kHz 70 V do 220 V CMC 32 · 10⁻⁶ · U\n50 kHz do 100 kHz 220 V do 1000 V CMC 65 · 10⁻⁶ · U\n100 kHz do 300 kHz 1 mV do 2,2 mV CMC 0,46 · 10⁻³ · U\n100 kHz do 300 kHz 2,2 mV do 7 mV CMC 0,22 · 10⁻³ · U\n100 kHz do 300 kHz 7 mV do 22 mV CMC 95 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 mV do 70 mV CMC 55 · 10⁻⁶ · U\n100 kHz do 300 kHz 70 mV do 220 mV CMC 42 · 10⁻⁶ · U\n100 kHz do 300 kHz 220 mV do 700 mV CMC 14 · 10⁻⁶ · U\n100 kHz do 300 kHz 700 mV do 2,2 V CMC 11 · 10⁻⁶ · U\n100 kHz do 300 kHz 2,2 V do 7 V CMC 13 · 10⁻⁶ · U\n100 kHz do 300 kHz 7 V do 22 V CMC 25 · 10⁻⁶ · U\n100 kHz do 300 kHz 22 V do 70 V CMC 25 · 10⁻⁶ · U\n300 kHz do 500 kHz 1 mV do 2,2 mV CMC 0,55 · 10⁻³ · U\n300 kHz do 500 kHz 2,2 mV do 7 mV CMC 0,33 · 10⁻³ · U\n300 kHz do 500 kHz 7 mV do 22 mV CMC 0,19 · 10⁻³ · U\n300 kHz do 500 kHz 22 mV do 70 mV CMC 0,11 · 10⁻³ · U\n300 kHz do 500 kHz 70 mV do 220 mV CMC 85 · 10⁻⁶ · U\n300 kHz do 500 kHz 220 mV do 700 mV CMC 27 · 10⁻⁶ · U\n300 kHz do 500 kHz 700 mV do 2,2 V CMC 22 · 10⁻⁶ · U\n300 kHz do 500 kHz 2,2 V do 7 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 7 V do 22 V CMC 30 · 10⁻⁶ · U\n300 kHz do 500 kHz 22 V do 70 V CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 1 mV do 2,2 mV CMC 0,60 · 10⁻³ · U\n500 kHz do 1 MHz 2,2 mV do 7 mV CMC 0,45 · 10⁻³ · U\n500 kHz do 1 MHz 7 mV do 22 mV CMC 0,21 · 10⁻³ · U\n500 kHz do 1 MHz 22 mV do 70 mV CMC 0,23 · 10⁻³ · U\n500 kHz do 1 MHz 70 mV do 220 mV CMC 0,1 · 10⁻³ · U\n500 kHz do 1 MHz 220 mV do 700 mV CMC 40 · 10⁻⁶ · U\n500 kHz do 1 MHz 700 mV do 2,2 V CMC 68 · 10⁻⁶ · U\n500 kHz do 1 MHz 2,2 V do 7 V CMC 95 · 10⁻⁶ · U\n500 kHz do 1 MHz 7 V do 22 V CMC 0,11 · 10⁻³ · U\n500 kHz do 1 MHz 22 V do 70 V CMC 0,13 · 10⁻³ · U\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.07.01","search_en":"Analogue voltmeters Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC voltage Internal procedure Direct method At permanent location (S) and outside of it (P) 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 300 kHz to 500 kHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz 500 kHz to 1 MHz Internal procedure PP.07.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.07.01","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"50 kHz bis 100 kHz","range":"1 mV to 2,2 mV","cmc":"0,41 · 10⁻³ · U"},{"name":"50 kHz bis 100 kHz","range":"2,2 mV to 7 mV","cmc":"0,2 · 10⁻³ · U"},{"name":"50 kHz bis 100 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"22 mV to 70 mV","cmc":"45 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"70 mV to 220 mV","cmc":"28 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"220 mV to 700 mV","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"700 mV to 2,2V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"70 V to 220 V","cmc":"32 · 10⁻⁶ · U"},{"name":"50 kHz bis 100 kHz","range":"220 V to 1000 V","cmc":"65 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"1 mV to 2,2 mV","cmc":"0,46 · 10⁻³ · U"},{"name":"100 kHz bis 300 kHz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"100 kHz bis 300 kHz","range":"7 mV to 22 mV","cmc":"95 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"22 mV to 70 mV","cmc":"55 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"70 mV to 220 mV","cmc":"42 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"220 mV to 700 mV","cmc":"14 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"700 mV to 2,2 V","cmc":"11 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"7 V to 22 V","cmc":"25 · 10⁻⁶ · U"},{"name":"100 kHz bis 300 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"1 mV to 2,2 mV","cmc":"0,55 · 10⁻³ · U"},{"name":"300 kHz bis 500 kHz","range":"2,2 mV to 7 mV","cmc":"0,33 · 10⁻³ · U"},{"name":"300 kHz bis 500 kHz","range":"7 mV to 22 mV","cmc":"0,19 · 10⁻³ · U"},{"name":"300 kHz bis 500 kHz","range":"22 mV to 70 mV","cmc":"0,11 · 10⁻³ · U"},{"name":"300 kHz bis 500 kHz","range":"70 mV to 220 mV","cmc":"85 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"220 mV to 700 mV","cmc":"27 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"700 mV to 2,2 V","cmc":"22 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"2,2 V to 7 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"7 V to 22 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz bis 500 kHz","range":"22 V to 70 V","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz bis 1 MHz","range":"1 mV to 2,2 mV","cmc":"0,60 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"2,2 mV to 7 mV","cmc":"0,45 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"7 mV to 22 mV","cmc":"0,21 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"22 mV to 70 mV","cmc":"0,23 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"70 mV to 220 mV","cmc":"0,1 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"220 mV to 700 mV","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz bis 1 MHz","range":"700 mV to 2,2 V","cmc":"68 · 10⁻⁶ · U"},{"name":"500 kHz bis 1 MHz","range":"2,2 V to 7 V","cmc":"95 · 10⁻⁶ · U"},{"name":"500 kHz bis 1 MHz","range":"7 V to 22 V","cmc":"0,11 · 10⁻³ · U"},{"name":"500 kHz bis 1 MHz","range":"22 V to 70 V","cmc":"0,13 · 10⁻³ · U"}],"reference_de":"Internes Verfahren PP.07.01","regulatory_area_de":"AC-Spannung","search_de":"Analoge Spannungsmessgeräte Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 300 kHz bis 500 kHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz 500 kHz bis 1 MHz Internes Verfahren PP.07.01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Analoge Spannungsmessgeräte","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"50 kHz 至 100 kHz","range":"1 mV to 2,2 mV","cmc":"0,41 · 10⁻³ · U"},{"name":"50 kHz 至 100 kHz","range":"2,2 mV to 7 mV","cmc":"0,2 · 10⁻³ · U"},{"name":"50 kHz 至 100 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"22 mV to 70 mV","cmc":"45 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"70 mV to 220 mV","cmc":"28 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"220 mV to 700 mV","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"700 mV to 2,2V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"70 V to 220 V","cmc":"32 · 10⁻⁶ · U"},{"name":"50 kHz 至 100 kHz","range":"220 V to 1000 V","cmc":"65 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"1 mV to 2,2 mV","cmc":"0,46 · 10⁻³ · U"},{"name":"100 kHz 至 300 kHz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"100 kHz 至 300 kHz","range":"7 mV to 22 mV","cmc":"95 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"22 mV to 70 mV","cmc":"55 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"70 mV to 220 mV","cmc":"42 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"220 mV to 700 mV","cmc":"14 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"700 mV to 2,2 V","cmc":"11 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"7 V to 22 V","cmc":"25 · 10⁻⁶ · U"},{"name":"100 kHz 至 300 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"1 mV to 2,2 mV","cmc":"0,55 · 10⁻³ · U"},{"name":"300 kHz 至 500 kHz","range":"2,2 mV to 7 mV","cmc":"0,33 · 10⁻³ · U"},{"name":"300 kHz 至 500 kHz","range":"7 mV to 22 mV","cmc":"0,19 · 10⁻³ · U"},{"name":"300 kHz 至 500 kHz","range":"22 mV to 70 mV","cmc":"0,11 · 10⁻³ · U"},{"name":"300 kHz 至 500 kHz","range":"70 mV to 220 mV","cmc":"85 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"220 mV to 700 mV","cmc":"27 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"700 mV to 2,2 V","cmc":"22 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"2,2 V to 7 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"7 V to 22 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz 至 500 kHz","range":"22 V to 70 V","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz 至 1 MHz","range":"1 mV to 2,2 mV","cmc":"0,60 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"2,2 mV to 7 mV","cmc":"0,45 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"7 mV to 22 mV","cmc":"0,21 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"22 mV to 70 mV","cmc":"0,23 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"70 mV to 220 mV","cmc":"0,1 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"220 mV to 700 mV","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz 至 1 MHz","range":"700 mV to 2,2 V","cmc":"68 · 10⁻⁶ · U"},{"name":"500 kHz 至 1 MHz","range":"2,2 V to 7 V","cmc":"95 · 10⁻⁶ · U"},{"name":"500 kHz 至 1 MHz","range":"7 V to 22 V","cmc":"0,11 · 10⁻³ · U"},{"name":"500 kHz 至 1 MHz","range":"22 V to 70 V","cmc":"0,13 · 10⁻³ · U"}],"reference_zh":"内部程序 PP.07.01","regulatory_area_zh":"交流电压","search_zh":"模拟电压表 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 300 kHz 至 500 kHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 500 kHz 至 1 MHz 内部程序 PP.07.01","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"模拟电压表","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"50 kHz až 100 kHz","range":"1 mV to 2,2 mV","cmc":"0,41 · 10⁻³ · U"},{"name":"50 kHz až 100 kHz","range":"2,2 mV to 7 mV","cmc":"0,2 · 10⁻³ · U"},{"name":"50 kHz až 100 kHz","range":"7 mV to 22 mV","cmc":"75 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"22 mV to 70 mV","cmc":"45 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"70 mV to 220 mV","cmc":"28 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"220 mV to 700 mV","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"700 mV to 2,2V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"7 V to 22 V","cmc":"11 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"70 V to 220 V","cmc":"32 · 10⁻⁶ · U"},{"name":"50 kHz až 100 kHz","range":"220 V to 1000 V","cmc":"65 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"1 mV to 2,2 mV","cmc":"0,46 · 10⁻³ · U"},{"name":"100 kHz až 300 kHz","range":"2,2 mV to 7 mV","cmc":"0,22 · 10⁻³ · U"},{"name":"100 kHz až 300 kHz","range":"7 mV to 22 mV","cmc":"95 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"22 mV to 70 mV","cmc":"55 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"70 mV to 220 mV","cmc":"42 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"220 mV to 700 mV","cmc":"14 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"700 mV to 2,2 V","cmc":"11 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"2,2 V to 7 V","cmc":"13 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"7 V to 22 V","cmc":"25 · 10⁻⁶ · U"},{"name":"100 kHz až 300 kHz","range":"22 V to 70 V","cmc":"25 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"1 mV to 2,2 mV","cmc":"0,55 · 10⁻³ · U"},{"name":"300 kHz až 500 kHz","range":"2,2 mV to 7 mV","cmc":"0,33 · 10⁻³ · U"},{"name":"300 kHz až 500 kHz","range":"7 mV to 22 mV","cmc":"0,19 · 10⁻³ · U"},{"name":"300 kHz až 500 kHz","range":"22 mV to 70 mV","cmc":"0,11 · 10⁻³ · U"},{"name":"300 kHz až 500 kHz","range":"70 mV to 220 mV","cmc":"85 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"220 mV to 700 mV","cmc":"27 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"700 mV to 2,2 V","cmc":"22 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"2,2 V to 7 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"7 V to 22 V","cmc":"30 · 10⁻⁶ · U"},{"name":"300 kHz až 500 kHz","range":"22 V to 70 V","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz až 1 MHz","range":"1 mV to 2,2 mV","cmc":"0,60 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"2,2 mV to 7 mV","cmc":"0,45 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"7 mV to 22 mV","cmc":"0,21 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"22 mV to 70 mV","cmc":"0,23 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"70 mV to 220 mV","cmc":"0,1 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"220 mV to 700 mV","cmc":"40 · 10⁻⁶ · U"},{"name":"500 kHz až 1 MHz","range":"700 mV to 2,2 V","cmc":"68 · 10⁻⁶ · U"},{"name":"500 kHz až 1 MHz","range":"2,2 V to 7 V","cmc":"95 · 10⁻⁶ · U"},{"name":"500 kHz až 1 MHz","range":"7 V to 22 V","cmc":"0,11 · 10⁻³ · U"},{"name":"500 kHz až 1 MHz","range":"22 V to 70 V","cmc":"0,13 · 10⁻³ · U"}],"reference_cs":"Vnitřní postup PP.07.01","regulatory_area_cs":"Napětí AC","search_cs":"Analogové měřiče napětí Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 300 kHz až 500 kHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz 500 kHz až 1 MHz Vnitřní postup PP.07.01","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analogové měřiče napětí"},{"_id":"f1f85c9a4da13ef6621bd54a","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Kalibratory\nMierniki prądu cyfrowe\nMultimetry","test_object_en":"Calibrators\nDigital ammeters\nMultimeters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"10 Hz do 40 Hz","range":"100 µA do 1 mA","cmc":"12 · 10⁻⁵ · I"},{"name":"10 Hz do 40 Hz","range":"1 mA do 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"10 Hz do 40 Hz","range":"10 mA do 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"10 Hz do 40 Hz","range":"1 A do 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"10 Hz do 40 Hz","range":"10 A do 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"40 Hz do 1 kHz","range":"100 µA do 1 mA","cmc":"16 · 10⁻⁵ · I"},{"name":"40 Hz do 1 kHz","range":"1 mA do 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"40 Hz do 1 kHz","range":"10 mA do 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"40 Hz do 1 kHz","range":"1 A do 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"40 Hz do 1 kHz","range":"10 A do 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"1 kHz do 10 kHz","range":"100 µA do 1 mA","cmc":"60 · 10⁻⁶ · I"},{"name":"1 kHz do 10 kHz","range":"1 mA do 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"1 kHz do 10 kHz","range":"10 mA do 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"1 kHz do 10 kHz","range":"1 A do 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"1 kHz do 10 kHz","range":"10 A do 20 A","cmc":"39 · 10⁻⁶ · I"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"100 µA to 1 mA","cmc":"12 · 10⁻⁵ · I"},{"name":"10 Hz to 40 Hz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"10 Hz to 40 Hz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"10 Hz to 40 Hz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"10 Hz to 40 Hz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"40 Hz to 1 kHz","range":"100 µA to 1 mA","cmc":"16 · 10⁻⁵ · I"},{"name":"40 Hz to 1 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"40 Hz to 1 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"40 Hz to 1 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"40 Hz to 1 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"1 kHz to 10 kHz","range":"100 µA to 1 mA","cmc":"60 · 10⁻⁶ · I"},{"name":"1 kHz to 10 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"1 kHz to 10 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"1 kHz to 10 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"1 kHz to 10 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 40 Hz 100 µA do 1 mA CMC 12 · 10⁻⁵ · I\n10 Hz do 40 Hz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n10 Hz do 40 Hz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n40 Hz do 1 kHz 100 µA do 1 mA CMC 16 · 10⁻⁵ · I\n40 Hz do 1 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n40 Hz do 1 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n1 kHz do 10 kHz 100 µA do 1 mA CMC 60 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Kalibratory\nMierniki prądu cyfrowe\nMultimetry Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 40 Hz 100 µA do 1 mA CMC 12 · 10⁻⁵ · I\n10 Hz do 40 Hz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n10 Hz do 40 Hz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n40 Hz do 1 kHz 100 µA do 1 mA CMC 16 · 10⁻⁵ · I\n40 Hz do 1 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n40 Hz do 1 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n1 kHz do 10 kHz 100 µA do 1 mA CMC 60 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-15 v.3.0 Kalibratory\nMierniki pradu cyfrowe\nMultimetry Wzorcowanie — Prad AC\nZakres:\n10 Hz do 40 Hz 100 µA do 1 mA CMC 12 · 10⁻⁵ · I\n10 Hz do 40 Hz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n10 Hz do 40 Hz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n40 Hz do 1 kHz 100 µA do 1 mA CMC 16 · 10⁻⁵ · I\n40 Hz do 1 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n40 Hz do 1 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n1 kHz do 10 kHz 100 µA do 1 mA CMC 60 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-15 v.3.0","search_en":"Calibrators Digital ammeters Multimeters Calibration — AC current Direct and indirect method; At permanent location (S) and outside of it (P) AC current Direct and indirect method At permanent location (S) and outside of it (P) 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 1 kHz to 10 kHz 1 kHz to 10 kHz 1 kHz to 10 kHz 1 kHz to 10 kHz 1 kHz to 10 kHz EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"10 Hz bis 40 Hz","range":"100 µA to 1 mA","cmc":"12 · 10⁻⁵ · I"},{"name":"10 Hz bis 40 Hz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"10 Hz bis 40 Hz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"10 Hz bis 40 Hz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"10 Hz bis 40 Hz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"40 Hz bis 1 kHz","range":"100 µA to 1 mA","cmc":"16 · 10⁻⁵ · I"},{"name":"40 Hz bis 1 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"40 Hz bis 1 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"40 Hz bis 1 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"40 Hz bis 1 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"1 kHz bis 10 kHz","range":"100 µA to 1 mA","cmc":"60 · 10⁻⁶ · I"},{"name":"1 kHz bis 10 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"1 kHz bis 10 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"1 kHz bis 10 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"1 kHz bis 10 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"}],"regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Digitale Strommessgeräte Multimeter Kalibrierung — Wechselstrom Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Strom Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 1 kHz bis 10 kHz 1 kHz bis 10 kHz 1 kHz bis 10 kHz 1 kHz bis 10 kHz 1 kHz bis 10 kHz EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nDigitale Strommessgeräte\nMultimeter","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"100 µA to 1 mA","cmc":"12 · 10⁻⁵ · I"},{"name":"10 Hz 至 40 Hz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"10 Hz 至 40 Hz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"10 Hz 至 40 Hz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"10 Hz 至 40 Hz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"40 Hz 至 1 kHz","range":"100 µA to 1 mA","cmc":"16 · 10⁻⁵ · I"},{"name":"40 Hz 至 1 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"40 Hz 至 1 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"40 Hz 至 1 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"40 Hz 至 1 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"1 kHz 至 10 kHz","range":"100 µA to 1 mA","cmc":"60 · 10⁻⁶ · I"},{"name":"1 kHz 至 10 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"1 kHz 至 10 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"1 kHz 至 10 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"1 kHz 至 10 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"}],"regulatory_area_zh":"交流电流","search_zh":"校准器 数字电流表 万用表 校准 — 交流电流 直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 交流电流 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 1 kHz 至 10 kHz 1 kHz 至 10 kHz 1 kHz 至 10 kHz 1 kHz 至 10 kHz 1 kHz 至 10 kHz EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n数字电流表\n万用表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"10 Hz až 40 Hz","range":"100 µA to 1 mA","cmc":"12 · 10⁻⁵ · I"},{"name":"10 Hz až 40 Hz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"10 Hz až 40 Hz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"10 Hz až 40 Hz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"10 Hz až 40 Hz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"40 Hz až 1 kHz","range":"100 µA to 1 mA","cmc":"16 · 10⁻⁵ · I"},{"name":"40 Hz až 1 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"40 Hz až 1 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"40 Hz až 1 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"40 Hz až 1 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"1 kHz až 10 kHz","range":"100 µA to 1 mA","cmc":"60 · 10⁻⁶ · I"},{"name":"1 kHz až 10 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"1 kHz až 10 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"1 kHz až 10 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"1 kHz až 10 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"}],"regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Digitální měřiče proudu Multimetry Kalibrace — Proud AC Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Proud AC Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 1 kHz až 10 kHz 1 kHz až 10 kHz 1 kHz až 10 kHz 1 kHz až 10 kHz 1 kHz až 10 kHz EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nDigitální měřiče proudu\nMultimetry"},{"_id":"19c57428d95209706f61f101","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Mierniki prądu analogowe","test_object_en":"Analogue ammeters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"10 Hz do 40 Hz","range":"100 µA do 1 mA","cmc":"12 · 10⁻⁵ · I"},{"name":"10 Hz do 40 Hz","range":"1 mA do 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"10 Hz do 40 Hz","range":"10 mA do 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"10 Hz do 40 Hz","range":"1 A do 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"10 Hz do 40 Hz","range":"10 A do 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"40 Hz do 1 kHz","range":"100 µA do 1 mA","cmc":"16 · 10⁻⁵ · I"},{"name":"40 Hz do 1 kHz","range":"1 mA do 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"40 Hz do 1 kHz","range":"10 mA do 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"40 Hz do 1 kHz","range":"1 A do 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"40 Hz do 1 kHz","range":"10 A do 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"1 kHz do 10 kHz","range":"100 µA do 1 mA","cmc":"60 · 10⁻⁶ · I"},{"name":"1 kHz do 10 kHz","range":"1 mA do 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"1 kHz do 10 kHz","range":"10 mA do 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"1 kHz do 10 kHz","range":"1 A do 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"1 kHz do 10 kHz","range":"10 A do 20 A","cmc":"39 · 10⁻⁶ · I"}],"parameters_en":[{"name":"10 Hz to 40 Hz","range":"100 µA to 1 mA","cmc":"12 · 10⁻⁵ · I"},{"name":"10 Hz to 40 Hz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"10 Hz to 40 Hz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"10 Hz to 40 Hz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"10 Hz to 40 Hz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"40 Hz to 1 kHz","range":"100 µA to 1 mA","cmc":"16 · 10⁻⁵ · I"},{"name":"40 Hz to 1 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"40 Hz to 1 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"40 Hz to 1 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"40 Hz to 1 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"1 kHz to 10 kHz","range":"100 µA to 1 mA","cmc":"60 · 10⁻⁶ · I"},{"name":"1 kHz to 10 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"1 kHz to 10 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"1 kHz to 10 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"1 kHz to 10 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 40 Hz 100 µA do 1 mA CMC 12 · 10⁻⁵ · I\n10 Hz do 40 Hz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n10 Hz do 40 Hz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n40 Hz do 1 kHz 100 µA do 1 mA CMC 16 · 10⁻⁵ · I\n40 Hz do 1 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n40 Hz do 1 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n1 kHz do 10 kHz 100 µA do 1 mA CMC 60 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.07.01","norm_bases":["PP.07.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Mierniki prądu analogowe Wzorcowanie — Prąd AC\nZakres:\n10 Hz do 40 Hz 100 µA do 1 mA CMC 12 · 10⁻⁵ · I\n10 Hz do 40 Hz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n10 Hz do 40 Hz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n40 Hz do 1 kHz 100 µA do 1 mA CMC 16 · 10⁻⁵ · I\n40 Hz do 1 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n40 Hz do 1 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n1 kHz do 10 kHz 100 µA do 1 mA CMC 60 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.07.01 Mierniki pradu analogowe Wzorcowanie — Prad AC\nZakres:\n10 Hz do 40 Hz 100 µA do 1 mA CMC 12 · 10⁻⁵ · I\n10 Hz do 40 Hz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n10 Hz do 40 Hz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n10 Hz do 40 Hz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n40 Hz do 1 kHz 100 µA do 1 mA CMC 16 · 10⁻⁵ · I\n40 Hz do 1 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n40 Hz do 1 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n40 Hz do 1 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\n1 kHz do 10 kHz 100 µA do 1 mA CMC 60 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 mA do 10 mA CMC 46 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 mA do 1 A CMC 17 · 10⁻⁶ · I\n1 kHz do 10 kHz 1 A do 10 A CMC 32 · 10⁻⁶ · I\n1 kHz do 10 kHz 10 A do 20 A CMC 39 · 10⁻⁶ · I\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.07.01","search_en":"Analogue ammeters Calibration — AC current Internal procedure; Direct method; At permanent location (S) and outside of it (P) AC current Internal procedure Direct method At permanent location (S) and outside of it (P) 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 10 Hz to 40 Hz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 1 kHz to 10 kHz 1 kHz to 10 kHz 1 kHz to 10 kHz 1 kHz to 10 kHz 1 kHz to 10 kHz Internal procedure PP.07.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.07.01","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"10 Hz bis 40 Hz","range":"100 µA to 1 mA","cmc":"12 · 10⁻⁵ · I"},{"name":"10 Hz bis 40 Hz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"10 Hz bis 40 Hz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"10 Hz bis 40 Hz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"10 Hz bis 40 Hz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"40 Hz bis 1 kHz","range":"100 µA to 1 mA","cmc":"16 · 10⁻⁵ · I"},{"name":"40 Hz bis 1 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"40 Hz bis 1 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"40 Hz bis 1 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"40 Hz bis 1 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"1 kHz bis 10 kHz","range":"100 µA to 1 mA","cmc":"60 · 10⁻⁶ · I"},{"name":"1 kHz bis 10 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"1 kHz bis 10 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"1 kHz bis 10 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"1 kHz bis 10 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"}],"reference_de":"Internes Verfahren PP.07.01","regulatory_area_de":"AC-Strom","search_de":"Analoge Strommessgeräte Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 10 Hz bis 40 Hz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 1 kHz bis 10 kHz 1 kHz bis 10 kHz 1 kHz bis 10 kHz 1 kHz bis 10 kHz 1 kHz bis 10 kHz Internes Verfahren PP.07.01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Analoge Strommessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"10 Hz 至 40 Hz","range":"100 µA to 1 mA","cmc":"12 · 10⁻⁵ · I"},{"name":"10 Hz 至 40 Hz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"10 Hz 至 40 Hz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"10 Hz 至 40 Hz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"10 Hz 至 40 Hz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"40 Hz 至 1 kHz","range":"100 µA to 1 mA","cmc":"16 · 10⁻⁵ · I"},{"name":"40 Hz 至 1 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"40 Hz 至 1 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"40 Hz 至 1 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"40 Hz 至 1 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"1 kHz 至 10 kHz","range":"100 µA to 1 mA","cmc":"60 · 10⁻⁶ · I"},{"name":"1 kHz 至 10 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"1 kHz 至 10 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"1 kHz 至 10 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"1 kHz 至 10 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"}],"reference_zh":"内部程序 PP.07.01","regulatory_area_zh":"交流电流","search_zh":"模拟电流表 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电流 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 10 Hz 至 40 Hz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 1 kHz 至 10 kHz 1 kHz 至 10 kHz 1 kHz 至 10 kHz 1 kHz 至 10 kHz 1 kHz 至 10 kHz 内部程序 PP.07.01","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"模拟电流表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"10 Hz až 40 Hz","range":"100 µA to 1 mA","cmc":"12 · 10⁻⁵ · I"},{"name":"10 Hz až 40 Hz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"10 Hz až 40 Hz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"10 Hz až 40 Hz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"10 Hz až 40 Hz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"40 Hz až 1 kHz","range":"100 µA to 1 mA","cmc":"16 · 10⁻⁵ · I"},{"name":"40 Hz až 1 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"40 Hz až 1 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"40 Hz až 1 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"40 Hz až 1 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"},{"name":"1 kHz až 10 kHz","range":"100 µA to 1 mA","cmc":"60 · 10⁻⁶ · I"},{"name":"1 kHz až 10 kHz","range":"1 mA to 10 mA","cmc":"46 · 10⁻⁶ · I"},{"name":"1 kHz až 10 kHz","range":"10 mA to 1 A","cmc":"17 · 10⁻⁶ · I"},{"name":"1 kHz až 10 kHz","range":"1 A to 10 A","cmc":"32 · 10⁻⁶ · I"},{"name":"1 kHz až 10 kHz","range":"10 A to 20 A","cmc":"39 · 10⁻⁶ · I"}],"reference_cs":"Vnitřní postup PP.07.01","regulatory_area_cs":"Proud AC","search_cs":"Analogové měřiče proudu Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Proud AC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 10 Hz až 40 Hz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 1 kHz až 10 kHz 1 kHz až 10 kHz 1 kHz až 10 kHz 1 kHz až 10 kHz 1 kHz až 10 kHz Vnitřní postup PP.07.01","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analogové měřiče proudu"},{"_id":"6eb6ce8b63feec9c6965f47d","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"40 Hz do 5 kHz","range":"1 mA do 2,2 A","cmc":"2 · 10⁻³ · I"},{"name":"40 Hz do 5 kHz","range":"2,2 A do 20 A","cmc":"3 · 10⁻³ · I"},{"name":"40 Hz do 5 kHz","range":"20 A do 800 A","cmc":"4 · 10⁻³ · I"}],"parameters_en":[{"name":"40 Hz to 5 kHz","range":"1 mA to 2,2 A","cmc":"2 · 10⁻³ · I"},{"name":"40 Hz to 5 kHz","range":"2,2 A to 20 A","cmc":"3 · 10⁻³ · I"},{"name":"40 Hz to 5 kHz","range":"20 A to 800 A","cmc":"4 · 10⁻³ · I"}],"technique":"Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 5 kHz 1 mA do 2,2 A CMC 2 · 10⁻³ · I\n40 Hz do 5 kHz 2,2 A do 20 A CMC 3 · 10⁻³ · I\n40 Hz do 5 kHz 20 A do 800 A CMC 4 · 10⁻³ · I\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Mierniki cęgowe Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 5 kHz 1 mA do 2,2 A CMC 2 · 10⁻³ · I\n40 Hz do 5 kHz 2,2 A do 20 A CMC 3 · 10⁻³ · I\n40 Hz do 5 kHz 20 A do 800 A CMC 4 · 10⁻³ · I\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-15 v.3.0 Mierniki cegowe Wzorcowanie — Prad AC\nZakres:\n40 Hz do 5 kHz 1 mA do 2,2 A CMC 2 · 10⁻³ · I\n40 Hz do 5 kHz 2,2 A do 20 A CMC 3 · 10⁻³ · I\n40 Hz do 5 kHz 20 A do 800 A CMC 4 · 10⁻³ · I\nMetoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-15 v.3.0","search_en":"Clamp meters Calibration — AC current Direct method; At permanent location (S) and outside of it (P) AC current Direct method At permanent location (S) and outside of it (P) 40 Hz to 5 kHz 40 Hz to 5 kHz 40 Hz to 5 kHz EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"40 Hz bis 5 kHz","range":"1 mA to 2,2 A","cmc":"2 · 10⁻³ · I"},{"name":"40 Hz bis 5 kHz","range":"2,2 A to 20 A","cmc":"3 · 10⁻³ · I"},{"name":"40 Hz bis 5 kHz","range":"20 A to 800 A","cmc":"4 · 10⁻³ · I"}],"regulatory_area_de":"AC-Strom","search_de":"Zangenmessgeräte Kalibrierung — Wechselstrom Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P) AC-Strom Direktes Verfahren Am festen Standort (S) und außerhalb (P) 40 Hz bis 5 kHz 40 Hz bis 5 kHz 40 Hz bis 5 kHz EURAMET cg-15 v.3.0","technique_de":"Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P)","techniques_de":["Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"40 Hz 至 5 kHz","range":"1 mA to 2,2 A","cmc":"2 · 10⁻³ · I"},{"name":"40 Hz 至 5 kHz","range":"2,2 A to 20 A","cmc":"3 · 10⁻³ · I"},{"name":"40 Hz 至 5 kHz","range":"20 A to 800 A","cmc":"4 · 10⁻³ · I"}],"regulatory_area_zh":"交流电流","search_zh":"钳形表 校准 — 交流电流 直接法；在固定地点 (S) 及固定地点以外 (P) 交流电流 直接法 在固定地点 (S) 及固定地点以外 (P) 40 Hz 至 5 kHz 40 Hz 至 5 kHz 40 Hz 至 5 kHz EURAMET cg-15 v.3.0","technique_zh":"直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"40 Hz až 5 kHz","range":"1 mA to 2,2 A","cmc":"2 · 10⁻³ · I"},{"name":"40 Hz až 5 kHz","range":"2,2 A to 20 A","cmc":"3 · 10⁻³ · I"},{"name":"40 Hz až 5 kHz","range":"20 A to 800 A","cmc":"4 · 10⁻³ · I"}],"regulatory_area_cs":"Proud AC","search_cs":"Klešťové měřiče Kalibrace — Proud AC Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P) Proud AC Přímá metoda V trvalé lokalitě (S) i mimo ni (P) 40 Hz až 5 kHz 40 Hz až 5 kHz 40 Hz až 5 kHz EURAMET cg-15 v.3.0","technique_cs":"Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Klešťové měřiče"},{"_id":"e935d542e04b74825f966b96","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Kalibratory\nMierniki rezystancji cyfrowe\nMultimetry","test_object_en":"Calibrators\nDigital ohmmeters\nMultimeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"1 Ω do 11 Ω","cmc":"0,12 · 10⁻³· R"},{"name":"","range":"11 Ω do 33 Ω","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"33 Ω do 110 Ω","cmc":"29 · 10⁻⁶ · R"},{"name":"","range":"110 Ω do 330 Ω","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"330 Ω do 1,1 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"1,1 kΩ do 3,3 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"3,3 kΩ do 11 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"11 kΩ do 33 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"33 kΩ do 110 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"110 kΩ do 330 kΩ","cmc":"32 · 10⁻⁶ · R"},{"name":"","range":"330 kΩ do 1,1 MΩ","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"1,1 MΩ do 3,3 MΩ","cmc":"62 · 10⁻⁶ · R"},{"name":"","range":"3,3 MΩ do 11 MΩ","cmc":"0,13 · 10⁻³ · R"},{"name":"","range":"11 MΩ do 33 MΩ","cmc":"0,25 · 10⁻³ · R"},{"name":"","range":"33 MΩ do 110 MΩ","cmc":"0,5 · 10⁻³ · R"},{"name":"","range":"110 MΩ do 330 MΩ","cmc":"3 · 10⁻³ · R"},{"name":"","range":"330 MΩ do 1,1 GΩ","cmc":"15 · 10⁻³ · R"}],"parameters_en":[{"name":"","range":"1 Ω to 11 Ω","cmc":"0,12 · 10⁻³· R"},{"name":"","range":"11 Ω to 33 Ω","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"33 Ω to 110 Ω","cmc":"29 · 10⁻⁶ · R"},{"name":"","range":"110 Ω to 330 Ω","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"330 Ω to 1,1 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"1,1 kΩ to 3,3 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"3,3 kΩ to 11 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"11 kΩ to 33 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"33 kΩ to 110 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"110 kΩ to 330 kΩ","cmc":"32 · 10⁻⁶ · R"},{"name":"","range":"330 kΩ to 1,1 MΩ","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"1,1 MΩ to 3,3 MΩ","cmc":"62 · 10⁻⁶ · R"},{"name":"","range":"3,3 MΩ to 11 MΩ","cmc":"0,13 · 10⁻³ · R"},{"name":"","range":"11 MΩ to 33 MΩ","cmc":"0,25 · 10⁻³ · R"},{"name":"","range":"33 MΩ to 110 MΩ","cmc":"0,5 · 10⁻³ · R"},{"name":"","range":"110 MΩ to 330 MΩ","cmc":"3 · 10⁻³ · R"},{"name":"","range":"330 MΩ to 1,1 GΩ","cmc":"15 · 10⁻³ · R"}],"technique":"Metoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct and indirect method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia i pośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct and indirect method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n1 Ω do 11 Ω CMC 0,12 · 10⁻³· R\n11 Ω do 33 Ω CMC 33 · 10⁻⁶ · R\n33 Ω do 110 Ω CMC 29 · 10⁻⁶ · R\n110 Ω do 330 Ω CMC 28 · 10⁻⁶ · R\n330 Ω do 1,1 kΩ CMC 28 · 10⁻⁶ · R\n1,1 kΩ do 3,3 kΩ CMC 28 · 10⁻⁶ · R\n3,3 kΩ do 11 kΩ CMC 28 · 10⁻⁶ · R\n11 kΩ do 33 kΩ CMC 28 · 10⁻⁶ · R\n33 kΩ do 110 kΩ CMC 28 · 10⁻⁶ · R\n110 kΩ do 330 kΩ CMC 32 · 10⁻⁶ · R\n330 kΩ do 1,1 MΩ CMC 33 · 10⁻⁶ · R\n1,1 MΩ do 3,3 MΩ CMC 62 · 10⁻⁶ · R\n3,3 MΩ do 11 MΩ CMC 0,13 · 10⁻³ · R\n11 MΩ do 33 MΩ CMC 0,25 · 10⁻³ · R\n33 MΩ do 110 MΩ CMC 0,5 · 10⁻³ · R\n110 MΩ do 330 MΩ CMC 3 · 10⁻³ · R\n330 MΩ do 1,1 GΩ CMC 15 · 10⁻³ · R\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-15 v.3.0","norm_bases":["EURAMET cg-15 v.3.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"S, P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured quantity (Ω)","search_text":"Kalibratory\nMierniki rezystancji cyfrowe\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n1 Ω do 11 Ω CMC 0,12 · 10⁻³· R\n11 Ω do 33 Ω CMC 33 · 10⁻⁶ · R\n33 Ω do 110 Ω CMC 29 · 10⁻⁶ · R\n110 Ω do 330 Ω CMC 28 · 10⁻⁶ · R\n330 Ω do 1,1 kΩ CMC 28 · 10⁻⁶ · R\n1,1 kΩ do 3,3 kΩ CMC 28 · 10⁻⁶ · R\n3,3 kΩ do 11 kΩ CMC 28 · 10⁻⁶ · R\n11 kΩ do 33 kΩ CMC 28 · 10⁻⁶ · R\n33 kΩ do 110 kΩ CMC 28 · 10⁻⁶ · R\n110 kΩ do 330 kΩ CMC 32 · 10⁻⁶ · R\n330 kΩ do 1,1 MΩ CMC 33 · 10⁻⁶ · R\n1,1 MΩ do 3,3 MΩ CMC 62 · 10⁻⁶ · R\n3,3 MΩ do 11 MΩ CMC 0,13 · 10⁻³ · R\n11 MΩ do 33 MΩ CMC 0,25 · 10⁻³ · R\n33 MΩ do 110 MΩ CMC 0,5 · 10⁻³ · R\n110 MΩ do 330 MΩ CMC 3 · 10⁻³ · R\n330 MΩ do 1,1 GΩ CMC 15 · 10⁻³ · R\nMetoda bezpośrednia i pośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-15 v.3.0 Kalibratory\nMierniki rezystancji cyfrowe\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n1 Ω do 11 Ω CMC 0,12 · 10⁻³· R\n11 Ω do 33 Ω CMC 33 · 10⁻⁶ · R\n33 Ω do 110 Ω CMC 29 · 10⁻⁶ · R\n110 Ω do 330 Ω CMC 28 · 10⁻⁶ · R\n330 Ω do 1,1 kΩ CMC 28 · 10⁻⁶ · R\n1,1 kΩ do 3,3 kΩ CMC 28 · 10⁻⁶ · R\n3,3 kΩ do 11 kΩ CMC 28 · 10⁻⁶ · R\n11 kΩ do 33 kΩ CMC 28 · 10⁻⁶ · R\n33 kΩ do 110 kΩ CMC 28 · 10⁻⁶ · R\n110 kΩ do 330 kΩ CMC 32 · 10⁻⁶ · R\n330 kΩ do 1,1 MΩ CMC 33 · 10⁻⁶ · R\n1,1 MΩ do 3,3 MΩ CMC 62 · 10⁻⁶ · R\n3,3 MΩ do 11 MΩ CMC 0,13 · 10⁻³ · R\n11 MΩ do 33 MΩ CMC 0,25 · 10⁻³ · R\n33 MΩ do 110 MΩ CMC 0,5 · 10⁻³ · R\n110 MΩ do 330 MΩ CMC 3 · 10⁻³ · R\n330 MΩ do 1,1 GΩ CMC 15 · 10⁻³ · R\nMetoda bezposrednia i posrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-15 v.3.0","search_en":"Calibrators Digital ohmmeters Multimeters Calibration — DC resistance Direct and indirect method; At permanent location (S) and outside of it (P) DC resistance Direct and indirect method At permanent location (S) and outside of it (P) EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"1 Ω to 11 Ω","cmc":"0,12 · 10⁻³· R"},{"name":"","range":"11 Ω to 33 Ω","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"33 Ω to 110 Ω","cmc":"29 · 10⁻⁶ · R"},{"name":"","range":"110 Ω to 330 Ω","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"330 Ω to 1,1 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"1,1 kΩ to 3,3 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"3,3 kΩ to 11 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"11 kΩ to 33 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"33 kΩ to 110 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"110 kΩ to 330 kΩ","cmc":"32 · 10⁻⁶ · R"},{"name":"","range":"330 kΩ to 1,1 MΩ","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"1,1 MΩ to 3,3 MΩ","cmc":"62 · 10⁻⁶ · R"},{"name":"","range":"3,3 MΩ to 11 MΩ","cmc":"0,13 · 10⁻³ · R"},{"name":"","range":"11 MΩ to 33 MΩ","cmc":"0,25 · 10⁻³ · R"},{"name":"","range":"33 MΩ to 110 MΩ","cmc":"0,5 · 10⁻³ · R"},{"name":"","range":"110 MΩ to 330 MΩ","cmc":"3 · 10⁻³ · R"},{"name":"","range":"330 MΩ to 1,1 GΩ","cmc":"15 · 10⁻³ · R"}],"regulatory_area_de":"DC-Widerstand","search_de":"Kalibratoren Digitale Widerstandsmessgeräte Multimeter Kalibrierung — DC-Widerstand Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Widerstand Direktes und indirektes Verfahren Am festen Standort (S) und außerhalb (P) EURAMET cg-15 v.3.0","technique_de":"Direktes und indirektes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Direktes und indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nDigitale Widerstandsmessgeräte\nMultimeter","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"1 Ω to 11 Ω","cmc":"0,12 · 10⁻³· R"},{"name":"","range":"11 Ω to 33 Ω","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"33 Ω to 110 Ω","cmc":"29 · 10⁻⁶ · R"},{"name":"","range":"110 Ω to 330 Ω","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"330 Ω to 1,1 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"1,1 kΩ to 3,3 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"3,3 kΩ to 11 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"11 kΩ to 33 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"33 kΩ to 110 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"110 kΩ to 330 kΩ","cmc":"32 · 10⁻⁶ · R"},{"name":"","range":"330 kΩ to 1,1 MΩ","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"1,1 MΩ to 3,3 MΩ","cmc":"62 · 10⁻⁶ · R"},{"name":"","range":"3,3 MΩ to 11 MΩ","cmc":"0,13 · 10⁻³ · R"},{"name":"","range":"11 MΩ to 33 MΩ","cmc":"0,25 · 10⁻³ · R"},{"name":"","range":"33 MΩ to 110 MΩ","cmc":"0,5 · 10⁻³ · R"},{"name":"","range":"110 MΩ to 330 MΩ","cmc":"3 · 10⁻³ · R"},{"name":"","range":"330 MΩ to 1,1 GΩ","cmc":"15 · 10⁻³ · R"}],"regulatory_area_zh":"直流电阻","search_zh":"校准器 数字电阻测量仪 万用表 校准 — 直流电阻 直接法和间接法；在固定地点 (S) 及固定地点以外 (P) 直流电阻 直接法和间接法 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-15 v.3.0","technique_zh":"直接法和间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法和间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n数字电阻测量仪\n万用表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"1 Ω to 11 Ω","cmc":"0,12 · 10⁻³· R"},{"name":"","range":"11 Ω to 33 Ω","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"33 Ω to 110 Ω","cmc":"29 · 10⁻⁶ · R"},{"name":"","range":"110 Ω to 330 Ω","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"330 Ω to 1,1 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"1,1 kΩ to 3,3 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"3,3 kΩ to 11 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"11 kΩ to 33 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"33 kΩ to 110 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"110 kΩ to 330 kΩ","cmc":"32 · 10⁻⁶ · R"},{"name":"","range":"330 kΩ to 1,1 MΩ","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"1,1 MΩ to 3,3 MΩ","cmc":"62 · 10⁻⁶ · R"},{"name":"","range":"3,3 MΩ to 11 MΩ","cmc":"0,13 · 10⁻³ · R"},{"name":"","range":"11 MΩ to 33 MΩ","cmc":"0,25 · 10⁻³ · R"},{"name":"","range":"33 MΩ to 110 MΩ","cmc":"0,5 · 10⁻³ · R"},{"name":"","range":"110 MΩ to 330 MΩ","cmc":"3 · 10⁻³ · R"},{"name":"","range":"330 MΩ to 1,1 GΩ","cmc":"15 · 10⁻³ · R"}],"regulatory_area_cs":"Odpor DC","search_cs":"Kalibrátory Digitální měřiče odporu Multimetry Kalibrace — Odpor DC Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P) Odpor DC Přímá a nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-15 v.3.0","technique_cs":"Přímá a nepřímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá a nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nDigitální měřiče odporu\nMultimetry"},{"_id":"dff53f699e1bf8626947de6f","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Mierniki rezystancji analogowe","test_object_en":"Analogue ohmmeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"1 Ω do 11 Ω","cmc":"0,12 · 10⁻³· R"},{"name":"","range":"11 Ω do 33 Ω","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"33 Ω do 110 Ω","cmc":"29 · 10⁻⁶ · R"},{"name":"","range":"110 Ω do 330 Ω","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"330 Ω do 1,1 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"1,1 kΩ do 3,3 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"3,3 kΩ do 11 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"11 kΩ do 33 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"33 kΩ do 110 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"110 kΩ do 330 kΩ","cmc":"32 · 10⁻⁶ · R"},{"name":"","range":"330 kΩ do 1,1 MΩ","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"1,1 MΩ do 3,3 MΩ","cmc":"62 · 10⁻⁶ · R"},{"name":"","range":"3,3 MΩ do 11 MΩ","cmc":"0,13 · 10⁻³ · R"},{"name":"","range":"11 MΩ do 33 MΩ","cmc":"0,25 · 10⁻³ · R"},{"name":"","range":"33 MΩ do 110 MΩ","cmc":"0,5 · 10⁻³ · R"},{"name":"","range":"110 MΩ do 330 MΩ","cmc":"3 · 10⁻³ · R"},{"name":"","range":"330 MΩ do 1,1 GΩ","cmc":"15 · 10⁻³ · R"}],"parameters_en":[{"name":"","range":"1 Ω to 11 Ω","cmc":"0,12 · 10⁻³· R"},{"name":"","range":"11 Ω to 33 Ω","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"33 Ω to 110 Ω","cmc":"29 · 10⁻⁶ · R"},{"name":"","range":"110 Ω to 330 Ω","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"330 Ω to 1,1 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"1,1 kΩ to 3,3 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"3,3 kΩ to 11 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"11 kΩ to 33 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"33 kΩ to 110 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"110 kΩ to 330 kΩ","cmc":"32 · 10⁻⁶ · R"},{"name":"","range":"330 kΩ to 1,1 MΩ","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"1,1 MΩ to 3,3 MΩ","cmc":"62 · 10⁻⁶ · R"},{"name":"","range":"3,3 MΩ to 11 MΩ","cmc":"0,13 · 10⁻³ · R"},{"name":"","range":"11 MΩ to 33 MΩ","cmc":"0,25 · 10⁻³ · R"},{"name":"","range":"33 MΩ to 110 MΩ","cmc":"0,5 · 10⁻³ · R"},{"name":"","range":"110 MΩ to 330 MΩ","cmc":"3 · 10⁻³ · R"},{"name":"","range":"330 MΩ to 1,1 GΩ","cmc":"15 · 10⁻³ · R"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n1 Ω do 11 Ω CMC 0,12 · 10⁻³· R\n11 Ω do 33 Ω CMC 33 · 10⁻⁶ · R\n33 Ω do 110 Ω CMC 29 · 10⁻⁶ · R\n110 Ω do 330 Ω CMC 28 · 10⁻⁶ · R\n330 Ω do 1,1 kΩ CMC 28 · 10⁻⁶ · R\n1,1 kΩ do 3,3 kΩ CMC 28 · 10⁻⁶ · R\n3,3 kΩ do 11 kΩ CMC 28 · 10⁻⁶ · R\n11 kΩ do 33 kΩ CMC 28 · 10⁻⁶ · R\n33 kΩ do 110 kΩ CMC 28 · 10⁻⁶ · R\n110 kΩ do 330 kΩ CMC 32 · 10⁻⁶ · R\n330 kΩ do 1,1 MΩ CMC 33 · 10⁻⁶ · R\n1,1 MΩ do 3,3 MΩ CMC 62 · 10⁻⁶ · R\n3,3 MΩ do 11 MΩ CMC 0,13 · 10⁻³ · R\n11 MΩ do 33 MΩ CMC 0,25 · 10⁻³ · R\n33 MΩ do 110 MΩ CMC 0,5 · 10⁻³ · R\n110 MΩ do 330 MΩ CMC 3 · 10⁻³ · R\n330 MΩ do 1,1 GΩ CMC 15 · 10⁻³ · R\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.07.01","norm_bases":["PP.07.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"S, P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured quantity (Ω)","search_text":"Mierniki rezystancji analogowe Wzorcowanie — Rezystancja DC\nZakres:\n1 Ω do 11 Ω CMC 0,12 · 10⁻³· R\n11 Ω do 33 Ω CMC 33 · 10⁻⁶ · R\n33 Ω do 110 Ω CMC 29 · 10⁻⁶ · R\n110 Ω do 330 Ω CMC 28 · 10⁻⁶ · R\n330 Ω do 1,1 kΩ CMC 28 · 10⁻⁶ · R\n1,1 kΩ do 3,3 kΩ CMC 28 · 10⁻⁶ · R\n3,3 kΩ do 11 kΩ CMC 28 · 10⁻⁶ · R\n11 kΩ do 33 kΩ CMC 28 · 10⁻⁶ · R\n33 kΩ do 110 kΩ CMC 28 · 10⁻⁶ · R\n110 kΩ do 330 kΩ CMC 32 · 10⁻⁶ · R\n330 kΩ do 1,1 MΩ CMC 33 · 10⁻⁶ · R\n1,1 MΩ do 3,3 MΩ CMC 62 · 10⁻⁶ · R\n3,3 MΩ do 11 MΩ CMC 0,13 · 10⁻³ · R\n11 MΩ do 33 MΩ CMC 0,25 · 10⁻³ · R\n33 MΩ do 110 MΩ CMC 0,5 · 10⁻³ · R\n110 MΩ do 330 MΩ CMC 3 · 10⁻³ · R\n330 MΩ do 1,1 GΩ CMC 15 · 10⁻³ · R\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.07.01 Mierniki rezystancji analogowe Wzorcowanie — Rezystancja DC\nZakres:\n1 Ω do 11 Ω CMC 0,12 · 10⁻³· R\n11 Ω do 33 Ω CMC 33 · 10⁻⁶ · R\n33 Ω do 110 Ω CMC 29 · 10⁻⁶ · R\n110 Ω do 330 Ω CMC 28 · 10⁻⁶ · R\n330 Ω do 1,1 kΩ CMC 28 · 10⁻⁶ · R\n1,1 kΩ do 3,3 kΩ CMC 28 · 10⁻⁶ · R\n3,3 kΩ do 11 kΩ CMC 28 · 10⁻⁶ · R\n11 kΩ do 33 kΩ CMC 28 · 10⁻⁶ · R\n33 kΩ do 110 kΩ CMC 28 · 10⁻⁶ · R\n110 kΩ do 330 kΩ CMC 32 · 10⁻⁶ · R\n330 kΩ do 1,1 MΩ CMC 33 · 10⁻⁶ · R\n1,1 MΩ do 3,3 MΩ CMC 62 · 10⁻⁶ · R\n3,3 MΩ do 11 MΩ CMC 0,13 · 10⁻³ · R\n11 MΩ do 33 MΩ CMC 0,25 · 10⁻³ · R\n33 MΩ do 110 MΩ CMC 0,5 · 10⁻³ · R\n110 MΩ do 330 MΩ CMC 3 · 10⁻³ · R\n330 MΩ do 1,1 GΩ CMC 15 · 10⁻³ · R\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.07.01","search_en":"Analogue ohmmeters Calibration — DC resistance Internal procedure; Direct method; At permanent location (S) and outside of it (P) DC resistance Internal procedure Direct method At permanent location (S) and outside of it (P) Internal procedure PP.07.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.07.01","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"1 Ω to 11 Ω","cmc":"0,12 · 10⁻³· R"},{"name":"","range":"11 Ω to 33 Ω","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"33 Ω to 110 Ω","cmc":"29 · 10⁻⁶ · R"},{"name":"","range":"110 Ω to 330 Ω","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"330 Ω to 1,1 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"1,1 kΩ to 3,3 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"3,3 kΩ to 11 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"11 kΩ to 33 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"33 kΩ to 110 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"110 kΩ to 330 kΩ","cmc":"32 · 10⁻⁶ · R"},{"name":"","range":"330 kΩ to 1,1 MΩ","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"1,1 MΩ to 3,3 MΩ","cmc":"62 · 10⁻⁶ · R"},{"name":"","range":"3,3 MΩ to 11 MΩ","cmc":"0,13 · 10⁻³ · R"},{"name":"","range":"11 MΩ to 33 MΩ","cmc":"0,25 · 10⁻³ · R"},{"name":"","range":"33 MΩ to 110 MΩ","cmc":"0,5 · 10⁻³ · R"},{"name":"","range":"110 MΩ to 330 MΩ","cmc":"3 · 10⁻³ · R"},{"name":"","range":"330 MΩ to 1,1 GΩ","cmc":"15 · 10⁻³ · R"}],"reference_de":"Internes Verfahren PP.07.01","regulatory_area_de":"DC-Widerstand","search_de":"Analoge Widerstandsmessgeräte Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Widerstand Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Internes Verfahren PP.07.01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Analoge Widerstandsmessgeräte","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"1 Ω to 11 Ω","cmc":"0,12 · 10⁻³· R"},{"name":"","range":"11 Ω to 33 Ω","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"33 Ω to 110 Ω","cmc":"29 · 10⁻⁶ · R"},{"name":"","range":"110 Ω to 330 Ω","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"330 Ω to 1,1 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"1,1 kΩ to 3,3 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"3,3 kΩ to 11 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"11 kΩ to 33 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"33 kΩ to 110 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"110 kΩ to 330 kΩ","cmc":"32 · 10⁻⁶ · R"},{"name":"","range":"330 kΩ to 1,1 MΩ","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"1,1 MΩ to 3,3 MΩ","cmc":"62 · 10⁻⁶ · R"},{"name":"","range":"3,3 MΩ to 11 MΩ","cmc":"0,13 · 10⁻³ · R"},{"name":"","range":"11 MΩ to 33 MΩ","cmc":"0,25 · 10⁻³ · R"},{"name":"","range":"33 MΩ to 110 MΩ","cmc":"0,5 · 10⁻³ · R"},{"name":"","range":"110 MΩ to 330 MΩ","cmc":"3 · 10⁻³ · R"},{"name":"","range":"330 MΩ to 1,1 GΩ","cmc":"15 · 10⁻³ · R"}],"reference_zh":"内部程序 PP.07.01","regulatory_area_zh":"直流电阻","search_zh":"模拟式电阻表 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流电阻 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 内部程序 PP.07.01","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"模拟式电阻表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"1 Ω to 11 Ω","cmc":"0,12 · 10⁻³· R"},{"name":"","range":"11 Ω to 33 Ω","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"33 Ω to 110 Ω","cmc":"29 · 10⁻⁶ · R"},{"name":"","range":"110 Ω to 330 Ω","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"330 Ω to 1,1 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"1,1 kΩ to 3,3 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"3,3 kΩ to 11 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"11 kΩ to 33 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"33 kΩ to 110 kΩ","cmc":"28 · 10⁻⁶ · R"},{"name":"","range":"110 kΩ to 330 kΩ","cmc":"32 · 10⁻⁶ · R"},{"name":"","range":"330 kΩ to 1,1 MΩ","cmc":"33 · 10⁻⁶ · R"},{"name":"","range":"1,1 MΩ to 3,3 MΩ","cmc":"62 · 10⁻⁶ · R"},{"name":"","range":"3,3 MΩ to 11 MΩ","cmc":"0,13 · 10⁻³ · R"},{"name":"","range":"11 MΩ to 33 MΩ","cmc":"0,25 · 10⁻³ · R"},{"name":"","range":"33 MΩ to 110 MΩ","cmc":"0,5 · 10⁻³ · R"},{"name":"","range":"110 MΩ to 330 MΩ","cmc":"3 · 10⁻³ · R"},{"name":"","range":"330 MΩ to 1,1 GΩ","cmc":"15 · 10⁻³ · R"}],"reference_cs":"Vnitřní postup PP.07.01","regulatory_area_cs":"Odpor DC","search_cs":"Analogové měřiče odporu Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Odpor DC Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) Vnitřní postup PP.07.01","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analogové měřiče odporu"},{"_id":"409c684f56bd4547e6283185","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury współpracujące z czujnikami termoelektrycznymi","test_object_en":"Temperature indicators (meters) for use with thermocouples","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"","range":"-200 °C do 1820 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"","range":"-200 °C to 1820 °C","cmc":"0,15 °C"}],"technique":"Metoda pośrednia elektryczna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Indirect electrical method; At permanent location (S) and outside of it (P)","techniques":["Metoda pośrednia elektryczna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Indirect electrical method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\n-200 °C do 1820 °C CMC 0,15 °C\nMetoda pośrednia elektryczna; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-11 v.2.0 PN-EN 60584-1:2014-04","norm_bases":["EURAMET cg-11 v.2.0","PN-EN 60584-1:2014-04"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Wskaźniki (mierniki) temperatury współpracujące z czujnikami termoelektrycznymi Wzorcowanie — Elektryczna symulacja wielkości\n-200 °C do 1820 °C CMC 0,15 °C\nMetoda pośrednia elektryczna; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-11 v.2.0 PN-EN 60584-1:2014-04 Wskazniki (mierniki) temperatury wspolpracujace z czujnikami termoelektrycznymi Wzorcowanie — Elektryczna symulacja wielkosci\n-200 °C do 1820 °C CMC 0,15 °C\nMetoda posrednia elektryczna; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-11 v.2.0 PN-EN 60584-1:2014-04","search_en":"Temperature indicators (meters) for use with thermocouples Calibration — Electrical simulation of quantities Indirect electrical method; At permanent location (S) and outside of it (P) Electrical simulation of quantities Indirect electrical method At permanent location (S) and outside of it (P) EURAMET cg-11 v.2.0 PN-EN 60584-1:2014-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-200 °C to 1820 °C","cmc":"0,15 °C"}],"regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (-messgeräte) für Thermoelemente Kalibrierung — Elektrische Simulation von Größen Elektrisches indirektes Verfahren; Am festen Standort (S) und außerhalb davon (P) Elektrische Simulation von Größen Elektrisches indirektes Verfahren Am festen Standort (S) und außerhalb (P) EURAMET cg-11 v.2.0 PN-EN 60584-1:2014-04","technique_de":"Elektrisches indirektes Verfahren; Am festen Standort (S) und außerhalb davon (P)","techniques_de":["Elektrisches indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Temperaturanzeiger (-messgeräte) für Thermoelemente","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-200 °C to 1820 °C","cmc":"0,15 °C"}],"regulatory_area_zh":"量值的电模拟","search_zh":"配用热电偶传感器的温度指示仪（表） 校准 — 物理量的电模拟 电气间接法；在固定地点 (S) 及固定地点以外 (P) 量值的电模拟 电气间接法 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-11 v.2.0 PN-EN 60584-1:2014-04","technique_zh":"电气间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["电气间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"配用热电偶传感器的温度指示仪（表）","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-200 °C to 1820 °C","cmc":"0,15 °C"}],"regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Ukazatele (měřidla) teploty pracující s termoelektrickými snímači Kalibrace — Elektrická simulace veličin Elektrická nepřímá metoda; Ve stálé lokalitě (S) i mimo ni (P) Elektrická simulace veličin Elektrická nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-11 v.2.0 PN-EN 60584-1:2014-04","technique_cs":"Elektrická nepřímá metoda; Ve stálé lokalitě (S) i mimo ni (P)","techniques_cs":["Elektrická nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Ukazatele (měřidla) teploty pracující s termoelektrickými snímači"},{"_id":"c9a54cda2ae04e13d0677b4f","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury współpracujące z czujnikami rezystancyjnymi","test_object_en":"Temperature indicators (meters) for use with resistance sensors","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electrical simulation of quantities","parameters":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,05 °C"}],"parameters_en":[{"name":"","range":"-200 °C to 850 °C","cmc":"0,05 °C"}],"technique":"Metoda pośrednia elektryczna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Indirect electrical method; At permanent location (S) and outside of it (P)","techniques":["Metoda pośrednia elektryczna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Indirect electrical method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\n-200 °C do 850 °C CMC 0,05 °C\nMetoda pośrednia elektryczna; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-11 v.2.0 PN-EN 60751:2022","norm_bases":["EURAMET cg-11 v.2.0","PN-EN 60751:2022"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electrical simulation of quantities","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Wskaźniki (mierniki) temperatury współpracujące z czujnikami rezystancyjnymi Wzorcowanie — Elektryczna symulacja wielkości\n-200 °C do 850 °C CMC 0,05 °C\nMetoda pośrednia elektryczna; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-11 v.2.0 PN-EN 60751:2022 Wskazniki (mierniki) temperatury wspolpracujace z czujnikami rezystancyjnymi Wzorcowanie — Elektryczna symulacja wielkosci\n-200 °C do 850 °C CMC 0,05 °C\nMetoda posrednia elektryczna; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-11 v.2.0 PN-EN 60751:2022","search_en":"Temperature indicators (meters) for use with resistance sensors Calibration — Electrical simulation of quantities Indirect electrical method; At permanent location (S) and outside of it (P) Electrical simulation of quantities Indirect electrical method At permanent location (S) and outside of it (P) EURAMET cg-11 v.2.0 PN-EN 60751:2022","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-200 °C bis 850 °C","cmc":"0,05 °C"}],"regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (-messgeräte) für Widerstandsthermometer Kalibrierung — Elektrische Simulation von Größen Elektrisches indirektes Verfahren; Am festen Standort (S) und außerhalb davon (P) Elektrische Simulation von Größen Elektrisches indirektes Verfahren Am festen Standort (S) und außerhalb (P) EURAMET cg-11 v.2.0 PN-EN 60751:2022","technique_de":"Elektrisches indirektes Verfahren; Am festen Standort (S) und außerhalb davon (P)","techniques_de":["Elektrisches indirektes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Temperaturanzeiger (-messgeräte) für Widerstandsthermometer","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-200 °C 至 850 °C","cmc":"0,05 °C"}],"regulatory_area_zh":"量值的电模拟","search_zh":"配用电阻传感器的温度指示仪（表） 校准 — 物理量的电模拟 电气间接法；在固定地点 (S) 及固定地点以外 (P) 量值的电模拟 电气间接法 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-11 v.2.0 PN-EN 60751:2022","technique_zh":"电气间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["电气间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"配用电阻传感器的温度指示仪（表）","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-200 °C do 850 °C","cmc":"0,05 °C"}],"regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Ukazatele (měřidla) teploty pracující s odporovými snímači Kalibrace — Elektrická simulace veličin Elektrická nepřímá metoda; Ve stálé lokalitě (S) i mimo ni (P) Elektrická simulace veličin Elektrická nepřímá metoda V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-11 v.2.0 PN-EN 60751:2022","technique_cs":"Elektrická nepřímá metoda; Ve stálé lokalitě (S) i mimo ni (P)","techniques_cs":["Elektrická nepřímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Ukazatele (měřidla) teploty pracující s odporovými snímači"},{"_id":"02b248aabc3a5525e3532373","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Anemometry","test_object_en":"Anemometers","methodology":"Wzorcowanie — Prędkość powietrza (przepływ – gazy)","methodology_en":"Calibration — Air velocity (flow – gases)","parameters":[{"name":"","range":"1 m/s do 5 m/s","cmc":"0,15 m/s"},{"name":"","range":"5 m/s do 10 m/s","cmc":"0,20 m/s"},{"name":"","range":"10 m/s do 20 m/s","cmc":"0,30 m/s"},{"name":"","range":"20 m/s do 25 m/s","cmc":"0,50 m/s"}],"parameters_en":[{"name":"","range":"1 m/s to 5 m/s","cmc":"0,15 m/s"},{"name":"","range":"5 m/s to 10 m/s","cmc":"0,20 m/s"},{"name":"","range":"10 m/s to 20 m/s","cmc":"0,30 m/s"},{"name":"","range":"20 m/s to 25 m/s","cmc":"0,50 m/s"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prędkość powietrza (przepływ – gazy)\nZakres:\n1 m/s do 5 m/s CMC 0,15 m/s\n5 m/s do 10 m/s CMC 0,20 m/s\n10 m/s do 20 m/s CMC 0,30 m/s\n20 m/s do 25 m/s CMC 0,50 m/s\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna PP.11.01","norm_bases":["PP.11.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prędkość powietrza (przepływ – gazy)","regulatory_area_en":"Air velocity (flow – gases)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Anemometry Wzorcowanie — Prędkość powietrza (przepływ – gazy)\nZakres:\n1 m/s do 5 m/s CMC 0,15 m/s\n5 m/s do 10 m/s CMC 0,20 m/s\n10 m/s do 20 m/s CMC 0,30 m/s\n20 m/s do 25 m/s CMC 0,50 m/s\nProcedura wewnętrzna; W stałej lokalizacji (S) Procedura wewnętrzna PP.11.01 Anemometry Wzorcowanie — Predkosc powietrza (przeplyw – gazy)\nZakres:\n1 m/s do 5 m/s CMC 0,15 m/s\n5 m/s do 10 m/s CMC 0,20 m/s\n10 m/s do 20 m/s CMC 0,30 m/s\n20 m/s do 25 m/s CMC 0,50 m/s\nProcedura wewnetrzna; W stalej lokalizacji (S) Procedura wewnetrzna PP.11.01","search_en":"Anemometers Calibration — Air velocity (flow – gases) Internal procedure; At permanent location (S) Air velocity (flow – gases) Internal procedure At permanent location (S) Internal procedure PP.11.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.11.01","methodology_de":"Kalibrierung — Luftgeschwindigkeit (Durchfluss – Gase)","parameters_de":[{"name":"","range":"1 m/s to 5 m/s","cmc":"0,15 m/s"},{"name":"","range":"5 m/s to 10 m/s","cmc":"0,20 m/s"},{"name":"","range":"10 m/s to 20 m/s","cmc":"0,30 m/s"},{"name":"","range":"20 m/s to 25 m/s","cmc":"0,50 m/s"}],"reference_de":"Internes Verfahren PP.11.01","regulatory_area_de":"Luftgeschwindigkeit (Durchfluss – Gase)","search_de":"Anemometer Kalibrierung — Luftgeschwindigkeit (Durchfluss – Gase) Internes Verfahren; Am festen Standort (S) Luftgeschwindigkeit (Durchfluss – Gase) Internes Verfahren Am festen Standort (S) Internes Verfahren PP.11.01","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Anemometer","methodology_zh":"校准 — 风速（流量 – 气体）","parameters_zh":[{"name":"","range":"1 m/s to 5 m/s","cmc":"0,15 m/s"},{"name":"","range":"5 m/s to 10 m/s","cmc":"0,20 m/s"},{"name":"","range":"10 m/s to 20 m/s","cmc":"0,30 m/s"},{"name":"","range":"20 m/s to 25 m/s","cmc":"0,50 m/s"}],"reference_zh":"内部程序 PP.11.01","regulatory_area_zh":"风速（流量 – 气体）","search_zh":"风速计 校准 — 风速（流量 – 气体） 内部程序；在固定地点 (S) 风速（流量 – 气体） 内部程序 在固定地点 (S) 内部程序 PP.11.01","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"风速计","methodology_cs":"Kalibrace — Rychlost vzduchu (průtok – plyny)","parameters_cs":[{"name":"","range":"1 m/s to 5 m/s","cmc":"0,15 m/s"},{"name":"","range":"5 m/s to 10 m/s","cmc":"0,20 m/s"},{"name":"","range":"10 m/s to 20 m/s","cmc":"0,30 m/s"},{"name":"","range":"20 m/s to 25 m/s","cmc":"0,50 m/s"}],"reference_cs":"Vnitřní postup PP.11.01","regulatory_area_cs":"Rychlost vzduchu (průtok – plyny)","search_cs":"Anemometry Kalibrace — Rychlost vzduchu (průtok – plyny) Vnitřní postup; Ve stálé lokalitě (S) Rychlost vzduchu (průtok – plyny) Vnitřní postup Ve stálé lokalitě (S) Vnitřní postup PP.11.01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Anemometry"},{"_id":"bdd8d8a40cd166d0898c4b18","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Klucze dynamometryczne","test_object_en":"Torque wrenches","methodology":"Wzorcowanie — Moment siły","methodology_en":"Calibration — Torque","parameters":[{"name":"","range":"1 N∙m do 3000 N∙m","cmc":"0,9 %"}],"parameters_en":[{"name":"","range":"1 N∙m to 3000 N∙m","cmc":"0,9 %"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moment siły\n1 N∙m do 3000 N∙m CMC 0,9 %\nW stałej lokalizacji (S)","reference":"PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","norm_bases":["PN-EN ISO 6789-1:2017-03","PN-EN ISO 6789-2:2017-03"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moment siły","regulatory_area_en":"Torque","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Klucze dynamometryczne Wzorcowanie — Moment siły\n1 N∙m do 3000 N∙m CMC 0,9 %\nW stałej lokalizacji (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03 Klucze dynamometryczne Wzorcowanie — Moment sily\n1 N∙m do 3000 N∙m CMC 0,9 %\nW stalej lokalizacji (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","search_en":"Torque wrenches Calibration — Torque At permanent location (S) Torque At permanent location (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Drehmoment","parameters_de":[{"name":"","range":"1 N∙m to 3000 N∙m","cmc":"0,9 %"}],"regulatory_area_de":"Drehmoment","search_de":"Drehmomentschlüssel Kalibrierung — Drehmoment Am festen Standort (S) Drehmoment Am festen Standort (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Drehmomentschlüssel","methodology_zh":"校准 — 力矩","parameters_zh":[{"name":"","range":"1 N∙m to 3000 N∙m","cmc":"0,9 %"}],"regulatory_area_zh":"力矩","search_zh":"扭矩扳手 校准 — 力矩 在固定地点 (S) 力矩 在固定地点 (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"扭矩扳手","methodology_cs":"Kalibrace — Moment síly","parameters_cs":[{"name":"","range":"1 N∙m to 3000 N∙m","cmc":"0,9 %"}],"regulatory_area_cs":"Moment síly","search_cs":"Momentové klíče Kalibrace — Moment síly Ve stálé lokalitě (S) Moment síly Ve stálé lokalitě (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Momentové klíče"},{"_id":"2c7c419f78fd0fa5324c8f58","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Wkrętaki dynamometryczne","test_object_en":"Torque screwdrivers","methodology":"Wzorcowanie — Moment siły","methodology_en":"Calibration — Torque","parameters":[{"name":"","range":"1 N∙m do 10 N∙m","cmc":"0,9 %"}],"parameters_en":[{"name":"","range":"1 N∙m to 10 N∙m","cmc":"0,9 %"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Moment siły\n1 N∙m do 10 N∙m CMC 0,9 %\nW stałej lokalizacji (S)","reference":"PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","norm_bases":["PN-EN ISO 6789-1:2017-03","PN-EN ISO 6789-2:2017-03"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Moment siły","regulatory_area_en":"Torque","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wkrętaki dynamometryczne Wzorcowanie — Moment siły\n1 N∙m do 10 N∙m CMC 0,9 %\nW stałej lokalizacji (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03 Wkretaki dynamometryczne Wzorcowanie — Moment sily\n1 N∙m do 10 N∙m CMC 0,9 %\nW stalej lokalizacji (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","search_en":"Torque screwdrivers Calibration — Torque At permanent location (S) Torque At permanent location (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Drehmoment","parameters_de":[{"name":"","range":"1 N∙m to 10 N∙m","cmc":"0,9 %"}],"regulatory_area_de":"Drehmoment","search_de":"Drehmomentschraubendreher Kalibrierung — Drehmoment Am festen Standort (S) Drehmoment Am festen Standort (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Drehmomentschraubendreher","methodology_zh":"校准 — 力矩","parameters_zh":[{"name":"","range":"1 N∙m to 10 N∙m","cmc":"0,9 %"}],"regulatory_area_zh":"力矩","search_zh":"扭矩螺丝刀 校准 — 力矩 在固定地点 (S) 力矩 在固定地点 (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"扭矩螺丝刀","methodology_cs":"Kalibrace — Moment síly","parameters_cs":[{"name":"","range":"1 N∙m to 10 N∙m","cmc":"0,9 %"}],"regulatory_area_cs":"Moment síly","search_cs":"Momentové šroubováky Kalibrace — Moment síly Ve stálé lokalitě (S) Moment síly Ve stálé lokalitě (S) PN-EN ISO 6789-1:2017-03 PN-EN ISO 6789-2:2017-03","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Momentové šroubováky"},{"_id":"2c385e97bde6ab43218784c8","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Termohigrometry\nHigrometry","test_object_en":"Thermohygrometers\nHygrometers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 5 °C do 10 °C","range":"5 %rh do 98 %rh","cmc":"1,2 %rh"},{"name":"zakres temperatur 10 °C do 40 °C","range":"5 %rh do 98 %rh","cmc":"0,8 %rh"},{"name":"zakres temperatur 40 °C do 90 °C","range":"5 %rh do 98 %rh","cmc":"1,5 %rh"}],"parameters_en":[{"name":"temperature range 5 °C to 10 °C","range":"5 %rh to 98 %rh","cmc":"1,2 %rh"},{"name":"temperature range 10 °C to 40 °C","range":"5 %rh to 98 %rh","cmc":"0,8 %rh"},{"name":"temperature range 40 °C to 90 °C","range":"5 %rh to 98 %rh","cmc":"1,5 %rh"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nZakres:\nzakres temperatur 5 °C do 10 °C 5 %rh do 98 %rh CMC 1,2 %rh\nzakres temperatur 10 °C do 40 °C 5 %rh do 98 %rh CMC 0,8 %rh\nzakres temperatur 40 °C do 90 °C 5 %rh do 98 %rh CMC 1,5 %rh\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.14.01","norm_bases":["PP.14.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Termohigrometry\nHigrometry Wzorcowanie — Wilgotność względna\nZakres:\nzakres temperatur 5 °C do 10 °C 5 %rh do 98 %rh CMC 1,2 %rh\nzakres temperatur 10 °C do 40 °C 5 %rh do 98 %rh CMC 0,8 %rh\nzakres temperatur 40 °C do 90 °C 5 %rh do 98 %rh CMC 1,5 %rh\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.14.01 Termohigrometry\nHigrometry Wzorcowanie — Wilgotnosc wzgledna\nZakres:\nzakres temperatur 5 °C do 10 °C 5 %rh do 98 %rh CMC 1,2 %rh\nzakres temperatur 10 °C do 40 °C 5 %rh do 98 %rh CMC 0,8 %rh\nzakres temperatur 40 °C do 90 °C 5 %rh do 98 %rh CMC 1,5 %rh\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.14.01","search_en":"Thermohygrometers Hygrometers Calibration — Relative humidity Internal procedure; At permanent location (S) and outside of it (P) Relative humidity Internal procedure At permanent location (S) and outside of it (P) temperature range 5 °C to 10 °C temperature range 10 °C to 40 °C temperature range 40 °C to 90 °C Internal procedure PP.14.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":28,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.14.01","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperaturbereich 5 °C bis 10 °C","range":"5 %rh to 98 %rh","cmc":"1,2 %rh"},{"name":"Temperaturbereich 10 °C bis 40 °C","range":"5 %rh to 98 %rh","cmc":"0,8 %rh"},{"name":"Temperaturbereich 40 °C bis 90 °C","range":"5 %rh to 98 %rh","cmc":"1,5 %rh"}],"reference_de":"Internes Verfahren PP.14.01","regulatory_area_de":"Relative Feuchte","search_de":"Thermohygrometer Hygrometer Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Relative Feuchte Internes Verfahren Am festen Standort (S) und außerhalb (P) Temperaturbereich 5 °C bis 10 °C Temperaturbereich 10 °C bis 40 °C Temperaturbereich 40 °C bis 90 °C Internes Verfahren PP.14.01","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Thermohygrometer\nHygrometer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围5 °C至10 °C","range":"5 %rh to 98 %rh","cmc":"1,2 %rh"},{"name":"温度范围10 °C至40 °C","range":"5 %rh to 98 %rh","cmc":"0,8 %rh"},{"name":"温度范围40 °C至90 °C","range":"5 %rh to 98 %rh","cmc":"1,5 %rh"}],"reference_zh":"内部程序 PP.14.01","regulatory_area_zh":"相对湿度","search_zh":"温湿度计 湿度计 校准 — 相对湿度 内部程序；在固定地点 (S) 及固定地点以外 (P) 相对湿度 内部程序 在固定地点 (S) 及固定地点以外 (P) 温度范围5 °C至10 °C 温度范围10 °C至40 °C 温度范围40 °C至90 °C 内部程序 PP.14.01","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"温湿度计\n湿度计","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"teplotní rozsah 5 °C až 10 °C","range":"5 %rh to 98 %rh","cmc":"1,2 %rh"},{"name":"teplotní rozsah 10 °C až 40 °C","range":"5 %rh to 98 %rh","cmc":"0,8 %rh"},{"name":"teplotní rozsah 40 °C až 90 °C","range":"5 %rh to 98 %rh","cmc":"1,5 %rh"}],"reference_cs":"Vnitřní postup PP.14.01","regulatory_area_cs":"Relativní vlhkost","search_cs":"Termohygrometry Vlhkoměry Kalibrace — Relativní vlhkost Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Relativní vlhkost Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) teplotní rozsah 5 °C až 10 °C teplotní rozsah 10 °C až 40 °C teplotní rozsah 40 °C až 90 °C Vnitřní postup PP.14.01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Termohygrometry\nVlhkoměry"},{"_id":"b6a0f0a4f867dfc822a36e3f","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Komory klimatyczne","test_object_en":"Climatic chambers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 5 °C do 90 °C","range":"5 %rh do 98 %rh","cmc":"1,5 %rh"}],"parameters_en":[{"name":"temperature range 5 °C to 90 °C","range":"5 %rh to 98 %rh","cmc":"1,5 %rh"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 90 °C 5 %rh do 98 %rh CMC 1,5 %rh\nW stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-20 v. 5.0","norm_bases":["EURAMET cg-20 v. 5.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Komory klimatyczne Wzorcowanie — Wilgotność względna\nzakres temperatur 5 °C do 90 °C 5 %rh do 98 %rh CMC 1,5 %rh\nW stałej lokalizacji (S) i poza nią (P) EURAMET cg-20 v. 5.0 Komory klimatyczne Wzorcowanie — Wilgotnosc wzgledna\nzakres temperatur 5 °C do 90 °C 5 %rh do 98 %rh CMC 1,5 %rh\nW stalej lokalizacji (S) i poza nia (P) EURAMET cg-20 v. 5.0","search_en":"Climatic chambers Calibration — Relative humidity At permanent location (S) and outside of it (P) Relative humidity At permanent location (S) and outside of it (P) temperature range 5 °C to 90 °C EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":29,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperaturbereich 5 °C bis 90 °C","range":"5 %rh to 98 %rh","cmc":"1,5 %rh"}],"regulatory_area_de":"Relative Feuchte","search_de":"Klimakammern Kalibrierung — Relative Feuchte Am festen Standort (S) und außerhalb (P) Relative Feuchte Am festen Standort (S) und außerhalb (P) Temperaturbereich 5 °C bis 90 °C EURAMET cg-20 v. 5.0","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Klimakammern","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围5 °C至90 °C","range":"5 %rh to 98 %rh","cmc":"1,5 %rh"}],"regulatory_area_zh":"相对湿度","search_zh":"气候箱 校准 — 相对湿度 在固定地点 (S) 及固定地点以外 (P) 相对湿度 在固定地点 (S) 及固定地点以外 (P) 温度范围5 °C至90 °C EURAMET cg-20 v. 5.0","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"气候箱","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"teplotní rozsah 5 °C až 90 °C","range":"5 %rh to 98 %rh","cmc":"1,5 %rh"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Klimatické komory Kalibrace — Relativní vlhkost V trvalé lokalitě (S) i mimo ni (P) Relativní vlhkost V trvalé lokalitě (S) i mimo ni (P) teplotní rozsah 5 °C až 90 °C EURAMET cg-20 v. 5.0","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Klimatické komory"},{"_id":"6110c01343d0cc3444d1ed02","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Wagi nieautomatyczne elektroniczne","test_object_en":"Non-automatic electronic weighing instruments","methodology":"Wzorcowanie — Masa (wagi)","methodology_en":"Calibration — Mass (weighing instruments)","parameters":[{"name":"","range":"do 500 g","cmc":"2,0 · 10⁻⁴ %"},{"name":"","range":"500 g do 20 kg","cmc":"1,1 · 10⁻³ %"},{"name":"","range":"20 kg do 60 kg","cmc":"3,3 · 10⁻² %"}],"parameters_en":[{"name":"","range":"up to 500 g","cmc":"2,0 · 10⁻⁴ %"},{"name":"","range":"500 g do 20 kg","cmc":"1,1 · 10⁻³ %"},{"name":"","range":"20 kg do 60 kg","cmc":"3,3 · 10⁻² %"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Masa (wagi)\nZakres:\ndo 500 g CMC 2,0 · 10⁻⁴ %\n500 g do 20 kg CMC 1,1 · 10⁻³ %\n20 kg do 60 kg CMC 3,3 · 10⁻² %\nW stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-18 v. 4.0","norm_bases":["EURAMET cg-18 v. 4.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Masa (wagi)","regulatory_area_en":"Mass (weighing instruments)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Wagi nieautomatyczne elektroniczne Wzorcowanie — Masa (wagi)\nZakres:\ndo 500 g CMC 2,0 · 10⁻⁴ %\n500 g do 20 kg CMC 1,1 · 10⁻³ %\n20 kg do 60 kg CMC 3,3 · 10⁻² %\nW stałej lokalizacji (S) i poza nią (P) EURAMET cg-18 v. 4.0 Wagi nieautomatyczne elektroniczne Wzorcowanie — Masa (wagi)\nZakres:\ndo 500 g CMC 2,0 · 10⁻⁴ %\n500 g do 20 kg CMC 1,1 · 10⁻³ %\n20 kg do 60 kg CMC 3,3 · 10⁻² %\nW stalej lokalizacji (S) i poza nia (P) EURAMET cg-18 v. 4.0","search_en":"Non-automatic electronic weighing instruments Calibration — Mass (weighing instruments) At permanent location (S) and outside of it (P) Mass (weighing instruments) At permanent location (S) and outside of it (P) EURAMET cg-18 v. 4.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":30,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Masse (Waagen)","parameters_de":[{"name":"","range":"bis 500 g","cmc":"2,0 · 10⁻⁴ %"},{"name":"","range":"500 g do 20 kg","cmc":"1,1 · 10⁻³ %"},{"name":"","range":"20 kg do 60 kg","cmc":"3,3 · 10⁻² %"}],"regulatory_area_de":"Masse (Waagen)","search_de":"Nichtselbsttätige elektronische Waagen Kalibrierung — Masse (Waagen) Am festen Standort (S) und außerhalb (P) Masse (Waagen) Am festen Standort (S) und außerhalb (P) EURAMET cg-18 v. 4.0","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Nichtselbsttätige elektronische Waagen","methodology_zh":"校准 — 质量（衡器）","parameters_zh":[{"name":"","range":"至 500 g","cmc":"2,0 · 10⁻⁴ %"},{"name":"","range":"500 g do 20 kg","cmc":"1,1 · 10⁻³ %"},{"name":"","range":"20 kg do 60 kg","cmc":"3,3 · 10⁻² %"}],"regulatory_area_zh":"质量（衡器）","search_zh":"非自动电子衡器 校准 — 质量（衡器） 在固定地点 (S) 及固定地点以外 (P) 质量（衡器） 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-18 v. 4.0","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"非自动电子衡器","methodology_cs":"Kalibrace — Hmotnost (váhy)","parameters_cs":[{"name":"","range":"do 500 g","cmc":"2,0 · 10⁻⁴ %"},{"name":"","range":"500 g do 20 kg","cmc":"1,1 · 10⁻³ %"},{"name":"","range":"20 kg do 60 kg","cmc":"3,3 · 10⁻² %"}],"regulatory_area_cs":"Hmotnost (váhy)","search_cs":"Elektronické váhy s neautomatickou činností Kalibrace — Hmotnost (váhy) V trvalé lokalitě (S) i mimo ni (P) Hmotnost (váhy) V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-18 v. 4.0","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Elektronické váhy s neautomatickou činností"},{"_id":"79e553407c2fc25ee9b325a7","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Barometry","test_object_en":"Barometers","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"700 hPa do 1200 hPa","cmc":"0,25 hPa"}],"parameters_en":[{"name":"","range":"700 hPa to 1200 hPa","cmc":"0,25 hPa"}],"technique":"Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\n700 hPa do 1200 hPa CMC 0,25 hPa\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-17 v.4.1","norm_bases":["EURAMET cg-17 v.4.1"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Barometry Wzorcowanie — Ciśnienie\n700 hPa do 1200 hPa CMC 0,25 hPa\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-17 v.4.1 Barometry Wzorcowanie — Cisnienie\n700 hPa do 1200 hPa CMC 0,25 hPa\nMetoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-17 v.4.1","search_en":"Barometers Calibration — Pressure Direct method; At permanent location (S) and outside of it (P) Pressure Direct method At permanent location (S) and outside of it (P) EURAMET cg-17 v.4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":31,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"700 hPa to 1200 hPa","cmc":"0,25 hPa"}],"regulatory_area_de":"Druck","search_de":"Barometer Kalibrierung — Druck Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P) Druck Direktes Verfahren Am festen Standort (S) und außerhalb (P) EURAMET cg-17 v.4.1","technique_de":"Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P)","techniques_de":["Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Barometer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"700 hPa to 1200 hPa","cmc":"0,25 hPa"}],"regulatory_area_zh":"压力","search_zh":"气压计 校准 — 压力 直接法；在固定地点 (S) 及固定地点以外 (P) 压力 直接法 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-17 v.4.1","technique_zh":"直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"气压计","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"700 hPa to 1200 hPa","cmc":"0,25 hPa"}],"regulatory_area_cs":"Tlak","search_cs":"Barometry Kalibrace — Tlak Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P) Tlak Přímá metoda V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-17 v.4.1","technique_cs":"Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Barometry"},{"_id":"21e7f6f1b1ba479b21927a37","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Ciśnieniomierze elektroniczne\nPrzetworniki ciśnienia","test_object_en":"Electronic pressure gauges\nPressure transmitters","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"","range":"-0,1 MPa do 0 MPa","cmc":"0,00003 MPa"},{"name":"","range":"0 MPa do 0,5 MPa","cmc":"0,00004 MPa"},{"name":"","range":"0,5 MPa do 1 MPa","cmc":"0,00013 MPa"},{"name":"","range":"1 MPa do 1,5 MPa","cmc":"0,00017 MPa"},{"name":"","range":"1,5 MPa do 2 MPa","cmc":"0,00027 MPa"},{"name":"","range":"2 MPa do 12,5 MPa","cmc":"0,0032 MPa"},{"name":"","range":"12,5 MPa do 25 MPa","cmc":"0,0040 MPa"},{"name":"","range":"25 MPa do 37,5 MPa","cmc":"0,0047 MPa"},{"name":"","range":"37,5 MPa do 50 MPa","cmc":"0,0060 MPa"},{"name":"","range":"50 MPa do 62,5 MPa","cmc":"0,0070 MPa"},{"name":"","range":"62,5 MPa do 75 MPa","cmc":"0,0080 MPa"},{"name":"","range":"75 MPa do 87,5 MPa","cmc":"0,0090 MPa"},{"name":"","range":"87,5 MPa do 100 MPa","cmc":"0,011 MPa"}],"parameters_en":[{"name":"","range":"-0,1 MPa to 0 MPa","cmc":"0,00003 MPa"},{"name":"","range":"0 MPa do 0,5 MPa","cmc":"0,00004 MPa"},{"name":"","range":"0,5 MPa do 1 MPa","cmc":"0,00013 MPa"},{"name":"","range":"1 MPa do 1,5 MPa","cmc":"0,00017 MPa"},{"name":"","range":"1,5 MPa do 2 MPa","cmc":"0,00027 MPa"},{"name":"","range":"2 MPa do 12,5 MPa","cmc":"0,0032 MPa"},{"name":"","range":"12,5 MPa do 25 MPa","cmc":"0,0040 MPa"},{"name":"","range":"25 MPa do 37,5 MPa","cmc":"0,0047 MPa"},{"name":"","range":"37,5 MPa do 50 MPa","cmc":"0,0060 MPa"},{"name":"","range":"50 MPa do 62,5 MPa","cmc":"0,0070 MPa"},{"name":"","range":"62,5 MPa do 75 MPa","cmc":"0,0080 MPa"},{"name":"","range":"75 MPa do 87,5 MPa","cmc":"0,0090 MPa"},{"name":"","range":"87,5 MPa do 100 MPa","cmc":"0,011 MPa"}],"technique":"Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Direct method; At permanent location (S) and outside of it (P)","techniques":["Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n-0,1 MPa do 0 MPa CMC 0,00003 MPa\n0 MPa do 0,5 MPa CMC 0,00004 MPa\n0,5 MPa do 1 MPa CMC 0,00013 MPa\n1 MPa do 1,5 MPa CMC 0,00017 MPa\n1,5 MPa do 2 MPa CMC 0,00027 MPa\n2 MPa do 12,5 MPa CMC 0,0032 MPa\n12,5 MPa do 25 MPa CMC 0,0040 MPa\n25 MPa do 37,5 MPa CMC 0,0047 MPa\n37,5 MPa do 50 MPa CMC 0,0060 MPa\n50 MPa do 62,5 MPa CMC 0,0070 MPa\n62,5 MPa do 75 MPa CMC 0,0080 MPa\n75 MPa do 87,5 MPa CMC 0,0090 MPa\n87,5 MPa do 100 MPa CMC 0,011 MPa\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-17 v.4.1","norm_bases":["EURAMET cg-17 v.4.1"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Ciśnieniomierze elektroniczne\nPrzetworniki ciśnienia Wzorcowanie — Ciśnienie\nZakres:\n-0,1 MPa do 0 MPa CMC 0,00003 MPa\n0 MPa do 0,5 MPa CMC 0,00004 MPa\n0,5 MPa do 1 MPa CMC 0,00013 MPa\n1 MPa do 1,5 MPa CMC 0,00017 MPa\n1,5 MPa do 2 MPa CMC 0,00027 MPa\n2 MPa do 12,5 MPa CMC 0,0032 MPa\n12,5 MPa do 25 MPa CMC 0,0040 MPa\n25 MPa do 37,5 MPa CMC 0,0047 MPa\n37,5 MPa do 50 MPa CMC 0,0060 MPa\n50 MPa do 62,5 MPa CMC 0,0070 MPa\n62,5 MPa do 75 MPa CMC 0,0080 MPa\n75 MPa do 87,5 MPa CMC 0,0090 MPa\n87,5 MPa do 100 MPa CMC 0,011 MPa\nMetoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) EURAMET cg-17 v.4.1 Cisnieniomierze elektroniczne\nPrzetworniki cisnienia Wzorcowanie — Cisnienie\nZakres:\n-0,1 MPa do 0 MPa CMC 0,00003 MPa\n0 MPa do 0,5 MPa CMC 0,00004 MPa\n0,5 MPa do 1 MPa CMC 0,00013 MPa\n1 MPa do 1,5 MPa CMC 0,00017 MPa\n1,5 MPa do 2 MPa CMC 0,00027 MPa\n2 MPa do 12,5 MPa CMC 0,0032 MPa\n12,5 MPa do 25 MPa CMC 0,0040 MPa\n25 MPa do 37,5 MPa CMC 0,0047 MPa\n37,5 MPa do 50 MPa CMC 0,0060 MPa\n50 MPa do 62,5 MPa CMC 0,0070 MPa\n62,5 MPa do 75 MPa CMC 0,0080 MPa\n75 MPa do 87,5 MPa CMC 0,0090 MPa\n87,5 MPa do 100 MPa CMC 0,011 MPa\nMetoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) EURAMET cg-17 v.4.1","search_en":"Electronic pressure gauges Pressure transmitters Calibration — Pressure Direct method; At permanent location (S) and outside of it (P) Pressure Direct method At permanent location (S) and outside of it (P) EURAMET cg-17 v.4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":32,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"","range":"-0,1 MPa bis 0 MPa","cmc":"0,00003 MPa"},{"name":"","range":"0 MPa do 0,5 MPa","cmc":"0,00004 MPa"},{"name":"","range":"0,5 MPa do 1 MPa","cmc":"0,00013 MPa"},{"name":"","range":"1 MPa do 1,5 MPa","cmc":"0,00017 MPa"},{"name":"","range":"1,5 MPa do 2 MPa","cmc":"0,00027 MPa"},{"name":"","range":"2 MPa do 12,5 MPa","cmc":"0,0032 MPa"},{"name":"","range":"12,5 MPa do 25 MPa","cmc":"0,0040 MPa"},{"name":"","range":"25 MPa do 37,5 MPa","cmc":"0,0047 MPa"},{"name":"","range":"37,5 MPa do 50 MPa","cmc":"0,0060 MPa"},{"name":"","range":"50 MPa do 62,5 MPa","cmc":"0,0070 MPa"},{"name":"","range":"62,5 MPa do 75 MPa","cmc":"0,0080 MPa"},{"name":"","range":"75 MPa do 87,5 MPa","cmc":"0,0090 MPa"},{"name":"","range":"87,5 MPa do 100 MPa","cmc":"0,011 MPa"}],"regulatory_area_de":"Druck","search_de":"Elektronische Druckmessgeräte Druckmessumformer Kalibrierung — Druck Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P) Druck Direktes Verfahren Am festen Standort (S) und außerhalb (P) EURAMET cg-17 v.4.1","technique_de":"Direktes Verfahren; Am festen Standort (S) und außerhalb davon (P)","techniques_de":["Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Elektronische Druckmessgeräte\nDruckmessumformer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"","range":"-0,1 MPa 至 0 MPa","cmc":"0,00003 MPa"},{"name":"","range":"0 MPa do 0,5 MPa","cmc":"0,00004 MPa"},{"name":"","range":"0,5 MPa do 1 MPa","cmc":"0,00013 MPa"},{"name":"","range":"1 MPa do 1,5 MPa","cmc":"0,00017 MPa"},{"name":"","range":"1,5 MPa do 2 MPa","cmc":"0,00027 MPa"},{"name":"","range":"2 MPa do 12,5 MPa","cmc":"0,0032 MPa"},{"name":"","range":"12,5 MPa do 25 MPa","cmc":"0,0040 MPa"},{"name":"","range":"25 MPa do 37,5 MPa","cmc":"0,0047 MPa"},{"name":"","range":"37,5 MPa do 50 MPa","cmc":"0,0060 MPa"},{"name":"","range":"50 MPa do 62,5 MPa","cmc":"0,0070 MPa"},{"name":"","range":"62,5 MPa do 75 MPa","cmc":"0,0080 MPa"},{"name":"","range":"75 MPa do 87,5 MPa","cmc":"0,0090 MPa"},{"name":"","range":"87,5 MPa do 100 MPa","cmc":"0,011 MPa"}],"regulatory_area_zh":"压力","search_zh":"电子压力计 压力变送器 校准 — 压力 直接法；在固定地点 (S) 及固定地点以外 (P) 压力 直接法 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-17 v.4.1","technique_zh":"直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电子压力计\n压力变送器","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"","range":"-0,1 MPa do 0 MPa","cmc":"0,00003 MPa"},{"name":"","range":"0 MPa do 0,5 MPa","cmc":"0,00004 MPa"},{"name":"","range":"0,5 MPa do 1 MPa","cmc":"0,00013 MPa"},{"name":"","range":"1 MPa do 1,5 MPa","cmc":"0,00017 MPa"},{"name":"","range":"1,5 MPa do 2 MPa","cmc":"0,00027 MPa"},{"name":"","range":"2 MPa do 12,5 MPa","cmc":"0,0032 MPa"},{"name":"","range":"12,5 MPa do 25 MPa","cmc":"0,0040 MPa"},{"name":"","range":"25 MPa do 37,5 MPa","cmc":"0,0047 MPa"},{"name":"","range":"37,5 MPa do 50 MPa","cmc":"0,0060 MPa"},{"name":"","range":"50 MPa do 62,5 MPa","cmc":"0,0070 MPa"},{"name":"","range":"62,5 MPa do 75 MPa","cmc":"0,0080 MPa"},{"name":"","range":"75 MPa do 87,5 MPa","cmc":"0,0090 MPa"},{"name":"","range":"87,5 MPa do 100 MPa","cmc":"0,011 MPa"}],"regulatory_area_cs":"Tlak","search_cs":"Elektronické tlakoměry Převodníky tlaku Kalibrace — Tlak Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P) Tlak Přímá metoda V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-17 v.4.1","technique_cs":"Přímá metoda; Ve stálé lokalitě (S) i mimo ni (P)","techniques_cs":["Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Elektronické tlakoměry\nPřevodníky tlaku"},{"_id":"271b9cba0f503a018ce89bde","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)","test_object_en":"Electrical thermometers (including electronic)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-90 °C do 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C do 160 °C","cmc":"0,08 °C"},{"name":"","range":"160 °C do 200 °C","cmc":"0,15 °C"},{"name":"","range":"200 °C do 250 °C","cmc":"0,25 °C"}],"parameters_en":[{"name":"","range":"-90 °C to 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C to 160 °C","cmc":"0,08 °C"},{"name":"","range":"160 °C to 200 °C","cmc":"0,15 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,25 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-90 °C do 100 °C CMC 0,05 °C\n100 °C do 160 °C CMC 0,08 °C\n160 °C do 200 °C CMC 0,15 °C\n200 °C do 250 °C CMC 0,25 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.19.01","norm_bases":["PP.19.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-90 °C do 100 °C CMC 0,05 °C\n100 °C do 160 °C CMC 0,08 °C\n160 °C do 200 °C CMC 0,15 °C\n200 °C do 250 °C CMC 0,25 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.19.01 Termometry elektryczne (w tym elektroniczne) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-90 °C do 100 °C CMC 0,05 °C\n100 °C do 160 °C CMC 0,08 °C\n160 °C do 200 °C CMC 0,15 °C\n200 °C do 250 °C CMC 0,25 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.19.01","search_en":"Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure At permanent location (S) and outside of it (P) Internal procedure PP.19.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":33,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.19.01","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-90 °C to 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C to 160 °C","cmc":"0,08 °C"},{"name":"","range":"160 °C to 200 °C","cmc":"0,15 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,25 °C"}],"reference_de":"Internes Verfahren PP.19.01","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) und außerhalb (P) Internes Verfahren PP.19.01","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-90 °C to 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C to 160 °C","cmc":"0,08 °C"},{"name":"","range":"160 °C to 200 °C","cmc":"0,15 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,25 °C"}],"reference_zh":"内部程序 PP.19.01","regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 校准 — 温度（电测温） 内部程序；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 在固定地点 (S) 及固定地点以外 (P) 内部程序 PP.19.01","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电测温度计（包括电子温度计）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-90 °C to 100 °C","cmc":"0,05 °C"},{"name":"","range":"100 °C to 160 °C","cmc":"0,08 °C"},{"name":"","range":"160 °C to 200 °C","cmc":"0,15 °C"},{"name":"","range":"200 °C to 250 °C","cmc":"0,25 °C"}],"reference_cs":"Vnitřní postup PP.19.01","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) Vnitřní postup PP.19.01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)"},{"_id":"83c8c55d051fc199e695893a","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Komory klimatyczne\nKomory termostatyczne","test_object_en":"Climatic chambers\nThermostatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do 200 °C","cmc":"0,5 °C"}],"parameters_en":[{"name":"","range":"-80 °C to 200 °C","cmc":"0,5 °C"}],"technique":"W stałej lokalizacji (S) i poza nią (P)","technique_en":"At permanent location (S) and outside of it (P)","techniques":["W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 200 °C CMC 0,5 °C\nW stałej lokalizacji (S) i poza nią (P)","reference":"EURAMET cg-20 v. 5.0","norm_bases":["EURAMET cg-20 v. 5.0"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Komory klimatyczne\nKomory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 200 °C CMC 0,5 °C\nW stałej lokalizacji (S) i poza nią (P) EURAMET cg-20 v. 5.0 Komory klimatyczne\nKomory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\n-80 °C do 200 °C CMC 0,5 °C\nW stalej lokalizacji (S) i poza nia (P) EURAMET cg-20 v. 5.0","search_en":"Climatic chambers Thermostatic chambers Calibration — Temperature (electrical thermometry) At permanent location (S) and outside of it (P) Temperature (electrical thermometry) At permanent location (S) and outside of it (P) EURAMET cg-20 v. 5.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":34,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to 200 °C","cmc":"0,5 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Klimakammern Thermostatkammern Kalibrierung — Temperatur (elektrische Thermometrie) Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Am festen Standort (S) und außerhalb (P) EURAMET cg-20 v. 5.0","technique_de":"Am festen Standort (S) und außerhalb (P)","techniques_de":["Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Klimakammern\nThermostatkammern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to 200 °C","cmc":"0,5 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"气候箱 恒温箱 校准 — 温度（电测温） 在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 在固定地点 (S) 及固定地点以外 (P) EURAMET cg-20 v. 5.0","technique_zh":"在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"气候箱\n恒温箱","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to 200 °C","cmc":"0,5 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Klimatické komory Termostatické komory Kalibrace — Teplota (elektrická termometrie) V trvalé lokalitě (S) i mimo ni (P) Teplota (elektrická termometrie) V trvalé lokalitě (S) i mimo ni (P) EURAMET cg-20 v. 5.0","technique_cs":"V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Klimatické komory\nTermostatické komory"},{"_id":"b8b5123eef873f801a94e483","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Komory do sterylizacji parowej (np. autoklawy)","test_object_en":"Steam sterilisation chambers (e.g. autoclaves)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"0 °C do 150 °C","cmc":"0,9 °C"}],"parameters_en":[{"name":"","range":"0 °C to 150 °C","cmc":"0,9 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n0 °C do 150 °C CMC 0,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.14.19.01","norm_bases":["PP.14.19.01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Komory do sterylizacji parowej (np. autoklawy) Wzorcowanie — Temperatura (termometria elektryczna)\n0 °C do 150 °C CMC 0,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.14.19.01 Komory do sterylizacji parowej (np. autoklawy) Wzorcowanie — Temperatura (termometria elektryczna)\n0 °C do 150 °C CMC 0,9 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.14.19.01","search_en":"Steam sterilisation chambers (e.g. autoclaves) Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure At permanent location (S) and outside of it (P) Internal procedure PP.14.19.01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":35,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.14.19.01","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"0 °C to 150 °C","cmc":"0,9 °C"}],"reference_de":"Internes Verfahren PP.14.19.01","regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Dampfsterilisationskammern (z. B. Autoklaven) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) und außerhalb (P) Internes Verfahren PP.14.19.01","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Dampfsterilisationskammern (z. B. Autoklaven)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"0 °C to 150 °C","cmc":"0,9 °C"}],"reference_zh":"内部程序 PP.14.19.01","regulatory_area_zh":"温度（电测温）","search_zh":"蒸汽灭菌室（如高压灭菌器） 校准 — 温度（电测温） 内部程序；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 在固定地点 (S) 及固定地点以外 (P) 内部程序 PP.14.19.01","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"蒸汽灭菌室（如高压灭菌器）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"0 °C to 150 °C","cmc":"0,9 °C"}],"reference_cs":"Vnitřní postup PP.14.19.01","regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Komory pro parní sterilizaci (např. autoklávy) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) Vnitřní postup PP.14.19.01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Komory pro parní sterilizaci (např. autoklávy)"},{"_id":"e88513f1ee86feb7612aef7e","lab_id":"6afa3b958989a133b76445bc","country":"PL","accr_number":"AP 176","accr_body":"PCA","test_object":"Pirometry (w tym pirometry radiacyjne, kamery termowizyjne)","test_object_en":"Pyrometers (including radiation pyrometers, thermal imaging cameras)","methodology":"Wzorcowanie — Temperatura (termometria radiacyjna)","methodology_en":"Calibration — Temperature (radiation thermometry)","parameters":[{"name":"","range":"-15 °C do 50 °C","cmc":"0,5 °C"},{"name":"","range":"50 °C do 120 °C","cmc":"0,8 °C"},{"name":"","range":"120 °C do 300 °C","cmc":"1,5 °C"},{"name":"","range":"300 °C do 500 °C","cmc":"2,5 °C"}],"parameters_en":[{"name":"","range":"-15 °C to 50 °C","cmc":"0,5 °C"},{"name":"","range":"50 °C to 120 °C","cmc":"0,8 °C"},{"name":"","range":"120 °C to 300 °C","cmc":"1,5 °C"},{"name":"","range":"300 °C to 500 °C","cmc":"2,5 °C"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do 50 °C CMC 0,5 °C\n50 °C do 120 °C CMC 0,8 °C\n120 °C do 300 °C CMC 1,5 °C\n300 °C do 500 °C CMC 2,5 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna PP.19.03","norm_bases":["PP.19.03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria radiacyjna)","regulatory_area_en":"Temperature (radiation thermometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Pirometry (w tym pirometry radiacyjne, kamery termowizyjne) Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do 50 °C CMC 0,5 °C\n50 °C do 120 °C CMC 0,8 °C\n120 °C do 300 °C CMC 1,5 °C\n300 °C do 500 °C CMC 2,5 °C\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna PP.19.03 Pirometry (w tym pirometry radiacyjne, kamery termowizyjne) Wzorcowanie — Temperatura (termometria radiacyjna)\nZakres:\n-15 °C do 50 °C CMC 0,5 °C\n50 °C do 120 °C CMC 0,8 °C\n120 °C do 300 °C CMC 1,5 °C\n300 °C do 500 °C CMC 2,5 °C\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna PP.19.03","search_en":"Pyrometers (including radiation pyrometers, thermal imaging cameras) Calibration — Temperature (radiation thermometry) Internal procedure; Direct method; At permanent location (S) and outside of it (P) Temperature (radiation thermometry) Internal procedure Direct method At permanent location (S) and outside of it (P) Internal procedure PP.19.03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":36,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure PP.19.03","methodology_de":"Kalibrierung — Temperatur (Strahlungsthermometrie)","parameters_de":[{"name":"","range":"-15 °C to 50 °C","cmc":"0,5 °C"},{"name":"","range":"50 °C to 120 °C","cmc":"0,8 °C"},{"name":"","range":"120 °C to 300 °C","cmc":"1,5 °C"},{"name":"","range":"300 °C to 500 °C","cmc":"2,5 °C"}],"reference_de":"Internes Verfahren PP.19.03","regulatory_area_de":"Temperatur (Strahlungsthermometrie)","search_de":"Pyrometer (einschließlich Strahlungspyrometer, Wärmebildkameras) Kalibrierung — Temperatur (Strahlungsthermometrie) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Temperatur (Strahlungsthermometrie) Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Internes Verfahren PP.19.03","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Pyrometer (einschließlich Strahlungspyrometer, Wärmebildkameras)","methodology_zh":"校准 — 温度（辐射测温）","parameters_zh":[{"name":"","range":"-15 °C to 50 °C","cmc":"0,5 °C"},{"name":"","range":"50 °C to 120 °C","cmc":"0,8 °C"},{"name":"","range":"120 °C to 300 °C","cmc":"1,5 °C"},{"name":"","range":"300 °C to 500 °C","cmc":"2,5 °C"}],"reference_zh":"内部程序 PP.19.03","regulatory_area_zh":"温度（辐射测温）","search_zh":"高温计（包括辐射高温计、热像仪） 校准 — 温度（辐射测温） 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 温度（辐射测温） 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 内部程序 PP.19.03","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"高温计（包括辐射高温计、热像仪）","methodology_cs":"Kalibrace — Teplota (radiační termometrie)","parameters_cs":[{"name":"","range":"-15 °C to 50 °C","cmc":"0,5 °C"},{"name":"","range":"50 °C to 120 °C","cmc":"0,8 °C"},{"name":"","range":"120 °C to 300 °C","cmc":"1,5 °C"},{"name":"","range":"300 °C to 500 °C","cmc":"2,5 °C"}],"reference_cs":"Vnitřní postup PP.19.03","regulatory_area_cs":"Teplota (radiační termometrie)","search_cs":"Pyrometry (včetně radiačních pyrometrů, termovizních kamer) Kalibrace — Teplota (radiační termometrie) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Teplota (radiační termometrie) Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) Vnitřní postup PP.19.03","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Pyrometry (včetně radiačních pyrometrů, termovizních kamer)"}],"has_pdf":true}