🇵🇱 Centralny Wojskowy Ośrodek Metrologii PL
Metrology & calibration
Centralny Wojskowy Ośrodek Metrologii is a calibration laboratory accredited by PCA under number AP 175 (Warszawa, Poland). Its accreditation scope covers 10 calibration items in the following areas: Metrology & calibration. Calibrated items include: - ambient dose equivalent rate, - surface emission rate, Alpha / beta surface contamination meters and monitors, Ionising radiation radiometers. Most frequently used calibration principles: Internal procedure; Direct measurement method; At permanent locatio…, Internal procedure; Direct measurement method Calibration in a clim…, Direct measurement method; At permanent location (S).
At a glance
- Accreditation number: PCA AP 175
- Calibration items in scope: 10
- Types of calibrated items: 8
- Calibration principles used: 4
- City: Warszawa, Poland
- Valid until: 05-11-2029
- Accreditation number
- AP 175
- Accreditation body
- PCA
- Address
- ul. Radiowa 2, 00-908 Warszawa
- City
- Warszawa, Poland
- Valid until
- 05-11-2029
What this laboratory calibrates (8)
- - ambient dose equivalent rate — 3 calibration items
- - surface emission rate — 3 calibration items
- Alpha / beta surface contamination meters and monitors — 3 calibration items
- Ionising radiation radiometers — 3 calibration items
- Electrical thermometers (including electronic) — 2 calibration items
- Electrical thermometers (with temperature recording) — 2 calibration items
- Mass standards and weights of accuracy classes E2, F1, F2, M1 — 1 calibration item
- Thermohygrometers — 1 calibration item
Calibration principles (4)
- Internal procedure; Direct measurement method; At permanent location (S) — 6 calibration items
- Internal procedure; Direct measurement method Calibration in a climatic chamber; At permanent location (S) — 2 calibration items
- Direct measurement method; At permanent location (S) — 1 calibration item
- Internal procedure; Direct measurement method Calibration in a liquid bath; At permanent location (S) — 1 calibration item
Certificate information
- Issue date
- 23.07.2026
- Issue no.
- 8
- Certificate date
- 09.07.2019
- Accreditation cycle
- 13.10.2025 — 05.11.2029
- Approved by
- Tadeusz Matras
Accreditation scope — calibration items (10)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Ionising radiation radiometers - ambient dose equivalent rate |
Calibration — Dosimetric quantities source ¹³⁷Cs — 30 µSv·h⁻¹ to 5 Sv·h⁻¹ · CMC 4,9 % Dosimetric quantities |
Internal procedure; Direct measurement method; At permanent location (S) | PP-16.01.03-3-2023-CWOM-DPO_G_A | |
| 2 | Ionising radiation radiometers - ambient dose equivalent rate |
Calibration — Dosimetric quantities source ¹³⁷Cs — 3 µSv·h⁻¹ to 30 mSv·h⁻¹ · CMC 4,9 % Dosimetric quantities |
Internal procedure; Direct measurement method; At permanent location (S) | PP-16.01.03-2-2017-CWOM-RK_100_G_A | |
| 3 | Ionising radiation radiometers - ambient dose equivalent rate |
Calibration — Dosimetric quantities source ¹³⁷Cs — 3 µSv·h⁻¹ to 700 µSv·h⁻¹ · CMC 4,9 % Dosimetric quantities |
Internal procedure; Direct measurement method; At permanent location (S) | PP-16.01.03-2-2017-CWOM-EKO_C_G_A | |
| 4 | Alpha / beta surface contamination meters and monitors - surface emission rate |
Calibration — Surface emission rate source ⁹⁰Sr — 20,35 s⁻¹·cm⁻² · CMC 4,0 % source ³⁶Cl — 13,88 s⁻¹·cm⁻² · CMC 4,0 % source ¹⁴C — 9,21 s⁻¹·cm⁻² · CMC 4,0 % source ²⁴¹Am — 8,10 s⁻¹·cm⁻² · CMC 6,0 % Surface emission rate |
Internal procedure; Direct measurement method; At permanent location (S) | PP-16.02.01-2-2017-CWOM-DPO_S_A | |
| 5 | Alpha / beta surface contamination meters and monitors - surface emission rate |
Calibration — Surface emission rate source ⁹⁰Sr — 20,35 s⁻¹·cm⁻² · CMC 4,0 % source ³⁶Cl — 13,88 s⁻¹·cm⁻² · CMC 4,0 % source ¹⁴C — 9,21 s⁻¹·cm⁻² · CMC 4,0 % source ²⁴¹Am — 8,10 s⁻¹·cm⁻² · CMC 6,0 % Surface emission rate |
Internal procedure; Direct measurement method; At permanent location (S) | PP-16.02.01-2-2017-CWOM-RK_100_S_A | |
| 6 | Alpha / beta surface contamination meters and monitors - surface emission rate |
Calibration — Surface emission rate source ⁹⁰Sr — 20,35 s⁻¹·cm⁻² · CMC 4,0 % source ³⁶Cl — 13,88 s⁻¹·cm⁻² · CMC 4,0 % source ¹⁴C — 9,21 s⁻¹·cm⁻² · CMC 4,0 % source ²⁴¹Am — 8,10 s⁻¹·cm⁻² · CMC 6,0 % source ²⁴¹Am — 1,72 s⁻¹·cm⁻² · CMC 6,0 % Surface emission rate |
Internal procedure; Direct measurement method; At permanent location (S) | PP-16.02.01-2-2017-CWOM-EKO_C_S_A | |
| 7 | Mass standards and weights of accuracy classes E2, F1, F2, M1 | Calibration — Mass (weights and mass standards) 1 mg · CMC 0,002 mg 2 mg · CMC 0,002 mg 5 mg · CMC 0,002 mg 10 mg · CMC 0,003 mg 20 mg · CMC 0,003 mg 50 mg · CMC 0,004 mg 100 mg · CMC 0,005 mg 200 mg · CMC 0,006 mg 500 mg · CMC 0,008 mg 1g · CMC 0,01 mg 2g · CMC 0,013 mg 5g · CMC 0,016 mg 10 g · CMC 0,02 mg 20 g · CMC 0,026 mg 50 g · CMC 0,033 mg 100 g · CMC 0,053 mg 200 g · CMC 0,1 mg 500 g · CMC 0,26 mg 1 kg · CMC 0,53 mg 2 kg · CMC 1 mg 5 kg · CMC 2,6 mg 10 kg · CMC 5,3 mg Mass (weights and mass standards) |
Direct measurement method; At permanent location (S) | OIML R 111-1:2004 | |
| 8 | Thermohygrometers | Calibration — Relative humidity in the temperature range 5 °C to 40 °C; 10 %rh to 95 %rh — 10 %rh to 50 %rh · CMC 1,3 %rh in the temperature range 5 °C to 40 °C; 10 %rh to 95 %rh — 50 %rh to 70 %rh · CMC 1,5 %rh in the temperature range 5 °C to 40 °C; 10 %rh to 95 %rh — 70 %rh to 90 %rh · CMC 1,6 %rh in the temperature range 5 °C to 40 °C; 10 %rh to 95 %rh — 90 %rh to 95 %rh · CMC 2,3 %rh Relative humidity |
Internal procedure; Direct measurement method Calibration in a climatic chamber; At permanent location (S) | PP-17.03.07-2-2025-CWOM-ZWO | |
| 9 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -10 °C to 40 °C · CMC 0,16 °C Temperature (electrical thermometry) |
Internal procedure; Direct measurement method Calibration in a climatic chamber; At permanent location (S) | PP-17.03.07-2-2025-CWOM-ZWO | |
| 10 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -80 °C to 200 °C · CMC 0,010 °C Temperature (electrical thermometry) |
Internal procedure; Direct measurement method Calibration in a liquid bath; At permanent location (S) | PP-17.01.03-6-2022-CWOM-TERMOMETRY_A | |
Reference standards (9)
OIML R 111-1:2004
PP-16.01.03-2-2017-CWOM-EKO_C_G_A
PP-16.01.03-2-2017-CWOM-RK_100_G_A
PP-16.01.03-3-2023-CWOM-DPO_G_A
PP-16.02.01-2-2017-CWOM-DPO_S_A
PP-16.02.01-2-2017-CWOM-EKO_C_S_A
PP-16.02.01-2-2017-CWOM-RK_100_S_A
PP-17.01.03-6-2022-CWOM-TERMOMETRY_A
PP-17.03.07-2-2025-CWOM-ZWO