Centralny Wojskowy Ośrodek Metrologii is a calibration laboratory accredited by PCA under number AP 175 (Warszawa, Poland). Its accreditation scope covers 10 calibration items in the following areas: Metrology & calibration. Calibrated items include: - ambient dose equivalent rate, - surface emission rate, Alpha / beta surface contamination meters and monitors, Ionising radiation radiometers. Most frequently used calibration principles: Internal procedure; Direct measurement method; At permanent locatio…, Internal procedure; Direct measurement method Calibration in a clim…, Direct measurement method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 175
  • Calibration items in scope: 10
  • Types of calibrated items: 8
  • Calibration principles used: 4
  • City: Warszawa, Poland
  • Valid until: 05-11-2029
Accreditation number
AP 175
Accreditation body
PCA
Address
ul. Radiowa 2, 00-908 Warszawa
City
Warszawa, Poland
Valid until
05-11-2029

What this laboratory calibrates (8)

Calibration principles (4)

Certificate information

Issue date
23.07.2026
Issue no.
8
Certificate date
09.07.2019
Accreditation cycle
13.10.2025 — 05.11.2029
Approved by
Tadeusz Matras

Accreditation scope — calibration items (10)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Ionising radiation radiometers
- ambient dose equivalent rate
Calibration — Dosimetric quantities
source ¹³⁷Cs — 30 µSv·h⁻¹ to 5 Sv·h⁻¹ · CMC 4,9 %
Dosimetric quantities
Internal procedure; Direct measurement method; At permanent location (S) PP-16.01.03-3-2023-CWOM-DPO_G_A
2 Ionising radiation radiometers
- ambient dose equivalent rate
Calibration — Dosimetric quantities
source ¹³⁷Cs — 3 µSv·h⁻¹ to 30 mSv·h⁻¹ · CMC 4,9 %
Dosimetric quantities
Internal procedure; Direct measurement method; At permanent location (S) PP-16.01.03-2-2017-CWOM-RK_100_G_A
3 Ionising radiation radiometers
- ambient dose equivalent rate
Calibration — Dosimetric quantities
source ¹³⁷Cs — 3 µSv·h⁻¹ to 700 µSv·h⁻¹ · CMC 4,9 %
Dosimetric quantities
Internal procedure; Direct measurement method; At permanent location (S) PP-16.01.03-2-2017-CWOM-EKO_C_G_A
4 Alpha / beta surface contamination meters and monitors
- surface emission rate
Calibration — Surface emission rate
source ⁹⁰Sr — 20,35 s⁻¹·cm⁻² · CMC 4,0 % source ³⁶Cl — 13,88 s⁻¹·cm⁻² · CMC 4,0 % source ¹⁴C — 9,21 s⁻¹·cm⁻² · CMC 4,0 % source ²⁴¹Am — 8,10 s⁻¹·cm⁻² · CMC 6,0 %
Surface emission rate
Internal procedure; Direct measurement method; At permanent location (S) PP-16.02.01-2-2017-CWOM-DPO_S_A
5 Alpha / beta surface contamination meters and monitors
- surface emission rate
Calibration — Surface emission rate
source ⁹⁰Sr — 20,35 s⁻¹·cm⁻² · CMC 4,0 % source ³⁶Cl — 13,88 s⁻¹·cm⁻² · CMC 4,0 % source ¹⁴C — 9,21 s⁻¹·cm⁻² · CMC 4,0 % source ²⁴¹Am — 8,10 s⁻¹·cm⁻² · CMC 6,0 %
Surface emission rate
Internal procedure; Direct measurement method; At permanent location (S) PP-16.02.01-2-2017-CWOM-RK_100_S_A
6 Alpha / beta surface contamination meters and monitors
- surface emission rate
Calibration — Surface emission rate
source ⁹⁰Sr — 20,35 s⁻¹·cm⁻² · CMC 4,0 % source ³⁶Cl — 13,88 s⁻¹·cm⁻² · CMC 4,0 % source ¹⁴C — 9,21 s⁻¹·cm⁻² · CMC 4,0 % source ²⁴¹Am — 8,10 s⁻¹·cm⁻² · CMC 6,0 % source ²⁴¹Am — 1,72 s⁻¹·cm⁻² · CMC 6,0 %
Surface emission rate
Internal procedure; Direct measurement method; At permanent location (S) PP-16.02.01-2-2017-CWOM-EKO_C_S_A
7 Mass standards and weights of accuracy classes E2, F1, F2, M1 Calibration — Mass (weights and mass standards)
1 mg · CMC 0,002 mg 2 mg · CMC 0,002 mg 5 mg · CMC 0,002 mg 10 mg · CMC 0,003 mg 20 mg · CMC 0,003 mg 50 mg · CMC 0,004 mg 100 mg · CMC 0,005 mg 200 mg · CMC 0,006 mg 500 mg · CMC 0,008 mg 1g · CMC 0,01 mg 2g · CMC 0,013 mg 5g · CMC 0,016 mg 10 g · CMC 0,02 mg 20 g · CMC 0,026 mg 50 g · CMC 0,033 mg 100 g · CMC 0,053 mg 200 g · CMC 0,1 mg 500 g · CMC 0,26 mg 1 kg · CMC 0,53 mg 2 kg · CMC 1 mg 5 kg · CMC 2,6 mg 10 kg · CMC 5,3 mg
Mass (weights and mass standards)
Direct measurement method; At permanent location (S) OIML R 111-1:2004
8 Thermohygrometers Calibration — Relative humidity
in the temperature range 5 °C to 40 °C; 10 %rh to 95 %rh — 10 %rh to 50 %rh · CMC 1,3 %rh in the temperature range 5 °C to 40 °C; 10 %rh to 95 %rh — 50 %rh to 70 %rh · CMC 1,5 %rh in the temperature range 5 °C to 40 °C; 10 %rh to 95 %rh — 70 %rh to 90 %rh · CMC 1,6 %rh in the temperature range 5 °C to 40 °C; 10 %rh to 95 %rh — 90 %rh to 95 %rh · CMC 2,3 %rh
Relative humidity
Internal procedure; Direct measurement method Calibration in a climatic chamber; At permanent location (S) PP-17.03.07-2-2025-CWOM-ZWO
9 Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Calibration — Temperature (electrical thermometry)
-10 °C to 40 °C · CMC 0,16 °C
Temperature (electrical thermometry)
Internal procedure; Direct measurement method Calibration in a climatic chamber; At permanent location (S) PP-17.03.07-2-2025-CWOM-ZWO
10 Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Calibration — Temperature (electrical thermometry)
-80 °C to 200 °C · CMC 0,010 °C
Temperature (electrical thermometry)
Internal procedure; Direct measurement method Calibration in a liquid bath; At permanent location (S) PP-17.01.03-6-2022-CWOM-TERMOMETRY_A

Reference standards (9)

OIML R 111-1:2004
PP-16.01.03-2-2017-CWOM-EKO_C_G_A
PP-16.01.03-2-2017-CWOM-RK_100_G_A
PP-16.01.03-3-2023-CWOM-DPO_G_A
PP-16.02.01-2-2017-CWOM-DPO_S_A
PP-16.02.01-2-2017-CWOM-EKO_C_S_A
PP-16.02.01-2-2017-CWOM-RK_100_S_A
PP-17.01.03-6-2022-CWOM-TERMOMETRY_A
PP-17.03.07-2-2025-CWOM-ZWO