🇵🇱 Hitachi Energy Poland Sp. z o.o. PL

PCA AP 168 • Przasnysz, Poland • 3 calibration items

Metrology & calibration

Hitachi Energy Poland Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 168 (Przasnysz, Poland). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Combined instrument transformers, Current transformers, Voltage transformers. Most frequently used calibration principles: Internal procedure; Bridge method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 168
  • Calibration items in scope: 3
  • Types of calibrated items: 3
  • Calibration principles used: 1
  • City: Przasnysz, Poland
  • Valid until: 20-12-2028
Accreditation number
AP 168
Accreditation body
PCA
Address
ul. Leszno 59, 06-300 Przasnysz
City
Przasnysz, Poland
Division
Laboratorium Wzorcujące Hitachi Energy w Przasnyszu
Valid until
20-12-2028

What this laboratory calibrates (3)

Calibration principles (1)

Certificate information

Issue date
30.10.2025
Issue no.
8
Certificate date
02.11.2021
Accreditation cycle
27.11.2024 — 20.12.2028
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (3)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The measurement uncertainty value for CMC expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Current transformers Calibration — High voltage and current
ratio of alternating electric currents (50 Hz or 60 Hz) — 5 A to 5000 A / 5 A · CMC 0,014 %; 1,3 min ratio of alternating electric currents (50 Hz or 60 Hz) — 5 A to 5000 A / 1 A · CMC 0,014 %; 1,3 min
High voltage and current
Internal procedure; Bridge method; At permanent location (S) KMW-02 w oparciu o PN-EN 61869-2:2013-06
2 Voltage transformers Calibration — High voltage and current
ratio of alternating electric voltages (50 Hz or 60 Hz) — 15 kV to 220/√3 kV // 100/√3 V to 220/√3 V · CMC 0,014 %; 1,3 min ratio of alternating electric voltages (50 Hz or 60 Hz) — 15 kV to 220/√3 kV // 100/3 V to 220/3 V · CMC 0,014 %; 1,3 min ratio of alternating electric voltages (50 Hz or 60 Hz) — 15 kV to 220/ √3 kV // 100 V to 120 V · CMC 0,014 %; 1,3 min
High voltage and current
Internal procedure; Bridge method; At permanent location (S) KMW-01 w oparciu o PN-EN 61869-3:2011
3 Combined instrument transformers Calibration — High voltage and current
ratio of alternating electric currents (50 Hz or 60 Hz) — 5 A to 5000 A / 5 A · CMC 0,014 %; 1,3 min ratio of alternating electric currents (50 Hz or 60 Hz) — 5 A to 5000 A / 1 A · CMC 0,014 %; 1,3 min ratio of alternating electric voltages (50 Hz or 60 Hz) — 15 kV to 220/√3 kV // 100/√3 V to 220/√3 V · CMC 0,014 %; 1,3 min ratio of alternating electric voltages (50 Hz or 60 Hz) — 15 kV to 220/√3 kV // 100/3 V to 220/3 V · CMC 0,014 %; 1,3 min ratio of alternating electric voltages (50 Hz or 60 Hz) — 15 kV to 220/ √3 kV // 100 V to 120 V · CMC 0,014 %; 1,3 min
High voltage and current
Internal procedure; Bridge method; At permanent location (S) KMW-01 KMW-02 w oparciu o PN-EN 61869-2:2013-06 Oraz w oparciu o PN-EN 61869-3:2011

Reference standards (4)

KMW-01
KMW-02
PN-EN 61869-2:2013-06
PN-EN 61869-3:2011