🇵🇱 STEMAD s.c. Weronika Madej, Andrzej Madej PL
Metrology & calibration
STEMAD s.c. Weronika Madej, Andrzej Madej is a calibration laboratory accredited by PCA under number AP 165 (Czeladź, Poland). Its accreditation scope covers 19 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Data acquisition cards, Power supplies, Power network parameter meters. Most frequently used calibration principles: Internal procedure; direct method; At permanent location (S) and ou…, Internal procedure; At permanent location (S) and outside of it (P), Internal procedure; direct method high AC voltage; At permanent loc….
At a glance
- Accreditation number: PCA AP 165
- Calibration items in scope: 19
- Types of calibrated items: 33
- Calibration principles used: 6
- City: Czeladź, Poland
- Valid until: 09-08-2028
- Accreditation number
- AP 165
- Accreditation body
- PCA
- Address
- ul. 3 Kwietnia 21, 41-253 Czeladź
- City
- Czeladź, Poland
- Division
- Measurement Laboratory
- Valid until
- 09-08-2028
What this laboratory calibrates (33)
- Multimeters — 8 calibration items
- Data acquisition cards — 7 calibration items
- Power supplies — 7 calibration items
- Power network parameter meters — 6 calibration items
- Calibrators — 5 calibration items
- Oscilloscopes — 5 calibration items
- Breakdown testers — 4 calibration items
- Analogue ammeters — 3 calibration items
- Analogue ohmmeters — 3 calibration items
- Digital ammeters — 3 calibration items
- Digital ohmmeters — 3 calibration items
- Electrical safety testers — 3 calibration items
- Analogue voltmeters — 2 calibration items
- Breakdown voltage meters — 2 calibration items
- Clamp meters — 2 calibration items
- and 18 more
Calibration principles (6)
- Internal procedure; direct method; At permanent location (S) and outside of it (P) — 8 calibration items
- Internal procedure; At permanent location (S) and outside of it (P) — 7 calibration items
- Internal procedure; direct method high AC voltage; At permanent location (S) — 1 calibration item
- Internal procedure; direct method high AC voltage; At permanent location (S) and outside of it (P) — 1 calibration item
- Internal procedure; direct method high DC voltage; At permanent location (S) — 1 calibration item
- Internal procedure; direct method high DC voltage; At permanent location (S) and outside of it (P) — 1 calibration item
Certificate information
- Issue date
- 09.07.2026
- Issue no.
- 11
- Certificate date
- 29.07.2020
- Accreditation cycle
- 18.07.2024 — 09.08.2028
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (19)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Generators Calibrators Data acquisition cards Analogue voltmeters Digital voltmeters Multimeters Oscilloscopes Power supplies |
Calibration — DC voltage 0 mV to 10 mV · CMC 0,5 µV 10 mV to 120 mV · CMC 1,3·10⁻⁵ · U + 0,2 µV 0,12 V to 1,2 V · CMC 1·10⁻⁵ · U + 0,7 µV 1,2 V to 12 V · CMC 1·10⁻⁵ · U + 7 µV 12 V to 120 V · CMC 1,2·10⁻⁵ · U + 0,09 mV 120 V to 1050 V · CMC 1,2·10⁻⁵ · U + 1,4 mV DC voltage |
Internal procedure; At permanent location (S) and outside of it (P) | PW-04 based on EURAMET cg-15 v.3.0 | |
| 2 | Breakdown voltage meters Breakdown testers Power supplies |
Calibration — DC voltage 0,01 kV to 40 kV · CMC 1·10⁻³ · U DC voltage |
Internal procedure; direct method; At permanent location (S) and outside of it (P) | PW-06 | |
| 3 | Calibrators Data acquisition cards Clamp meters Analogue ammeters Digital ammeters Multimeters Measuring probes Power supplies |
Calibration — DC current 10 µA to 120 µA · CMC 3·10⁻⁵ · I + 1 nA 0,12 mA to 1,2 mA · CMC 2·10⁻⁵ · I + 5 nA 1,2 mA to 12 mA · CMC 3·10⁻⁵ · I + 0,05 µA 12 mA to 120 mA · CMC 2·10⁻⁵ · I + 0,2 µA 0,12 A to 1,05 A · CMC 2·10⁻⁴ · I + 15 µA 1,05 A to 120 A · CMC 7,5·10⁻⁵ · I + 1 mA 120 A to 600 A · CMC 7,5·10⁻⁵ · I + 5 mA 600 A to 1200 A · CMC 1·10⁻⁴ · I + 10 mA DC current |
Internal procedure; At permanent location (S) and outside of it (P) | PW-04 based on EURAMET cg-15 v.3.0 | |
| 4 | Generators Calibrators Data acquisition cards Analogue voltmeters Digital voltmeters Multimeters Power supplies |
Calibration — AC voltage 40 Hz to 1 kHz — 1 mV to 12 mV · CMC 4·10⁻⁴ · U + 3 µV 40 Hz to 1 kHz — 12 mV to 120 mV · CMC 2·10⁻⁴ · U + 3 µV 40 Hz to 1 kHz — 0,12 V to 1,2 V · CMC 1,2·10⁻⁴ · U + 0,03 mV 40 Hz to 1 kHz — 1,2 V to 12 V · CMC 1,2·10⁻⁴ · U + 0,3 mV 40 Hz to 1 kHz — 12 V to 120 V · CMC 3·10⁻⁴ · U + 2 mV 40 Hz to 1 kHz — 120 V to 1050 V · CMC 5,5·10⁻⁴ · U + 0,05 V 1 kHz to 20 kHz — 1 mV to 12 mV · CMC 5·10⁻⁴ · U + 3 µV 1 kHz to 20 kHz — 12 mV to 120 mV · CMC 3·10⁻⁴ · U + 3 µV 1 kHz to 20 kHz — 0,12 V to 1,2 V · CMC 3·10⁻⁴ · U + 0,02 mV 1 kHz to 20 kHz — 1,2 V to 12 V · CMC 3·10⁻⁴ · U + 0,2 mV 1 kHz to 20 kHz — 12 V to 120 V · CMC 3·10⁻⁴ · U + 3 mV 1 kHz to 20 kHz — 120 V to 700 V · CMC 8·10⁻⁴ · U + 40 mV AC voltage |
Internal procedure; At permanent location (S) and outside of it (P) | PW-04 based on EURAMET cg-15 v.3.0 | |
| 5 | Oscilloscopes Scopemeters |
Calibration — AC voltage 40 Hz to 20 kHz — 0,001 V to 300 V · CMC 4 · 10⁻³ · U 20 kHz to 125 MHz — 0,001 V to 3 V · CMC 1,7 · 10⁻² · U AC voltage |
Internal procedure; At permanent location (S) and outside of it (P) | PW-01 based on EURAMET cg-7 v.1.0 | |
| 6 | Breakdown voltage meters Breakdown testers Power supplies |
Calibration — AC voltage 50 Hz to 60 Hz — 0,01 kV to 40 kV · CMC 2,5·10⁻³ · U AC voltage |
Internal procedure; direct method; At permanent location (S) and outside of it (P) | PW-06 | |
| 7 | Calibrators Data acquisition cards Clamp meters Analogue ammeters Digital ammeters Multimeters Measuring probes Power supplies |
Calibration — AC current 50 Hz to 60 Hz — 10 µA to 100,5 µA · CMC 8 · 10⁻⁴ · I + 15 nA 50 Hz to 60 Hz — 0,1005 mA to 1,05 mA · CMC 8 · 10⁻⁴ · I + 0,15 µA 50 Hz to 60 Hz — 1,05 mA to 10,5 mA · CMC 6,2 · 10⁻⁴ · I + 1,5 µA 50 Hz to 60 Hz — 10,5 A to 105 mA · CMC 6,2 · 10⁻⁴ · I + 15 µA 50 Hz to 60 Hz — 0,105 A to 1,05 A · CMC 9 · 10⁻⁴ · I + 0,18 mA 50 Hz to 60 Hz — 1,05 A to 30 A · CMC 2 · 10⁻⁴ · I + 1 mA 50 Hz to 60 Hz — 30 A to 300 A · CMC 2,5 · 10⁻⁴ · I + 1 mA 50 Hz to 60 Hz — 300 A to 1200 A · CMC 2,5 · 10⁻⁴ · I + 0,05 A AC current |
Internal procedure; At permanent location (S) and outside of it (P) | PW-04 based on EURAMET cg-15 v.3.0 | |
| 8 | Calibrators Data acquisition cards Analogue ammeters Digital ammeters Multimeters Power supplies |
Calibration — AC current 1 kHz — 10 µA to 100,5 µA · CMC 6,2·10⁻⁴ · I + 14 nA 1 kHz — 0,1005 mA to 1,05 mA · CMC 6,2·10⁻⁴ · I + 0,15 µA 1 kHz — 1,05 mA to 10,5 mA · CMC 6,2·10⁻⁴ · I + 1,5 µA 1 kHz — 10,5 mA to 105 mA · CMC 6,2·10⁻⁴ · I + 15 µA 1 kHz — 0,105 A to 1,05 A · CMC 9·10⁻⁴ · I + 0,18 mA 1 kHz — 1,05 A to 10,5 A · CMC 1,5·10⁻³ · I + 3,5 mA 1 kHz — 10,5 A to 30,5 A · CMC 1,5·10⁻³ · I + 10 mA AC current |
Internal procedure; At permanent location (S) and outside of it (P) | PW-04 based on EURAMET cg-15 v.3.0 | |
| 9 | Resistance calibrators Data acquisition cards Analogue ohmmeters Digital ohmmeters Power network parameter meters Insulation resistance meters Multimeters |
Calibration — DC resistance 0,001 Ω to 1,2 Ω · CMC 2,8·10⁻⁵ · R + 7 µΩ 1,2 Ω to 12 Ω · CMC 1,9·10⁻⁵ · R + 34 µΩ 12 Ω to 120 Ω · CMC 1,7·10⁻⁵ · R + 0,1 mΩ 0,12 kΩ to 1,2 kΩ · CMC 1,5·10⁻⁵ · R + 0,9 mΩ 1,2 kΩ to 12 kΩ · CMC 1,8·10⁻⁵ · R + 9 mΩ 12 kΩ to 120 kΩ · CMC 1,8·10⁻⁵ · R + 1 Ω 0,12 MΩ to 1,2 MΩ · CMC 2,2·10⁻⁵ · R + 2,3 Ω 1,2 MΩ to 12 MΩ · CMC 2,8·10⁻⁵ · R + 0,1 kΩ 12 MΩ to 90 MΩ · CMC 2·10⁻⁴ · R 90 MΩ to 900 MΩ · CMC 6·10⁻⁴ · R 0,9 GΩ to 9 GΩ · CMC 2,5·10⁻³ · R 9 GΩ to 1000 GΩ · CMC 2,7·10⁻² · R Fixed points: — 0,0001 Ω · CMC 2·10⁻³ · R Fixed points: — 0,001 Ω · CMC 2·10⁻⁴ · R Fixed points: — 0,01 Ω; 0,1 Ω · CMC 1·10⁻⁴ · R Fixed points: — 1Ω; 10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ · CMC 3·10⁻⁵ · R Fixed points: — 1 MΩ · CMC 6·10⁻⁵ · R Fixed points: — 1 GΩ · CMC 2·10⁻³ · R Fixed points: — 10 GΩ · CMC 5·10⁻³ · R Fixed points: — 50 GΩ; 100 GΩ; 200 GΩ · CMC 1·10⁻² · R Fixed points: — 250 GΩ; 500 GΩ; 1 TΩ · CMC 2,5·10⁻² · R DC resistance |
Internal procedure; At permanent location (S) and outside of it (P) | PW-04 based on EURAMET cg-15 v.3.0 | |
| 10 | Analogue ohmmeters Digital ohmmeters Power network parameter meters Insulation resistance meters Multimeters |
Calibration — DC resistance 100 Ω to 1000 kΩ · CMC 2·10⁻⁴ · R 1 MΩ to 15 MΩ · CMC 5·10⁻⁴ · R 20 MΩ to 90 MΩ · CMC 1·10⁻³ · R 0,1 GΩ to 2 GΩ · CMC 2·10⁻³ · R 5 GΩ to 20 GΩ · CMC 5·10⁻³ · R 50 GΩ to 200 GΩ · CMC 1·10⁻² · R 0,25 TΩ to 1 TΩ · CMC 2,5·10⁻² · R DC resistance |
Internal procedure; direct method; At permanent location (S) and outside of it (P) | PW-02 | |
| 11 | Resistance calibrators Data acquisition cards Oscilloscopes Scopemeters Fixed resistors Variable resistors Resistance standards |
Calibration — DC resistance 0,001 kΩ to 1,2 Ω · CMC 2,8·10⁻⁵ · R + 7 µΩ 1,2 Ω to 12 Ω · CMC 1,9·10⁻⁵ · R + 34 µΩ 12 Ω to 120 Ω · CMC 1,7·10⁻⁵ · R + 0,1 mΩ 0,12 kΩ to 1,2 kΩ · CMC 1,5·10⁻⁵ · R + 0,9 mΩ 1,2 kΩ to 12 kΩ · CMC 1,8·10⁻⁵ · R + 9 mΩ 12 kΩ to 120 kΩ · CMC 1,8·10⁻⁵ · R + 1 Ω 0,12 MΩ to 1,2 MΩ · CMC 2,2·10⁻⁵ · R + 2,3 Ω 1,2 MΩ to 12 MΩ · CMC 2,8·10⁻⁵ · R + 0,1 kΩ 12 MΩ to 90 MΩ · CMC 2·10⁻⁴ · R 90 MΩ to 900 MΩ · CMC 6·10⁻⁴ · R 0,9 GΩ to 9 GΩ · CMC 2,5·10⁻⁴ · R 9 GΩ to 1000 GΩ · CMC 2,7·10⁻² · R DC resistance |
Internal procedure; direct method; At permanent location (S) and outside of it (P) | PW-05 | |
| 12 | Power network parameter meters Analogue ohmmeters Digital ohmmeters Bridges Multimeters |
Calibration — AC resistance 50 Hz — 0,1 Ω to 100 kΩ · CMC 5·10⁻⁴ · R 50 Hz to 1 kHz — 0,001 Ω; 0,01 Ω; 0,1 Ω · CMC 3·10⁻³ · R 50 Hz to 1 kHz — 1 Ω; 10 Ω; 100 Ω; 1 kΩ; · CMC 2·10⁻³ · R 50 Hz to 1 kHz — 10 kΩ; 100 kΩ · CMC 2·10⁻³ · R AC resistance |
Internal procedure; direct method; At permanent location (S) and outside of it (P) | PW-03 | |
| 13 | Protective conductor (PE) resistance meters Power network parameter meters Electrical safety testers |
Calibration — AC resistance 50 Hz — 10 mΩ to 1000 mΩ · CMC 5·10⁻³ · R AC resistance |
Internal procedure; direct method; At permanent location (S) and outside of it (P) | PW-03 | |
| 14 | Kilovoltmeters | Calibration — High voltage and current 0,01 kV to 6 kV · CMC 1·10⁻³ · U High voltage and current |
Internal procedure; direct method high DC voltage; At permanent location (S) | PW-06 | |
| 15 | Power network parameter meters Breakdown testers Electrical safety testers Voltage sources |
Calibration — High voltage and current 0,01 kV to 40 kV · CMC 1·10⁻³ · U High voltage and current |
Internal procedure; direct method high DC voltage; At permanent location (S) and outside of it (P) | PW-06 | |
| 16 | Kilovoltmeters | Calibration — High voltage and current 50 kHz to 60 kHz — 0,01 kV to 5 kV · CMC 2,5·10⁻³ · U High voltage and current |
Internal procedure; direct method high AC voltage; At permanent location (S) | PW-06 | |
| 17 | Power network parameter meters Breakdown testers Electrical safety testers Voltage sources |
Calibration — High voltage and current 50 kHz to 60kHz — 0,01 kV to 40 kV · CMC 2,5·10⁻³ · U High voltage and current |
Internal procedure; direct method high AC voltage; At permanent location (S) and outside of it (P) | PW-06 | |
| 18 | Period meters Period generators Oscilloscopes |
Calibration — Time (time interval) 3,3 ns to 1 s · CMC 1,5·10⁻⁶ · t + 100 ps Time (time interval) |
Internal procedure; direct method; At permanent location (S) and outside of it (P) | PW-01 | |
| 19 | Frequency generators Quartz generators Digital frequency meters Oscilloscopes |
Calibration — Frequency 1 Hz to 2,7 GHz · CMC 1·10⁻⁶ · f + 15 µHz Frequency |
Internal procedure; direct method; At permanent location (S) and outside of it (P) | PW-01 | |
Reference standards (8)
EURAMET cg-15 v.3.0
EURAMET cg-7 v.1.0
PW-01
PW-02
PW-03
PW-04
PW-05
PW-06