{"lab":{"_id":"6af798960ecd48de0c7068a2","accr_number":"AP 165","country":"PL","imported_at":"2026-11-13T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. 3 Kwietnia 21, 41-253 Czeladź","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"29.07.2020","city":"Czeladź","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.","cycle_from":"18.07.2024","cycle_to":"09.08.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"7.01","pl":"napięcie DC","en":"DC voltage","de":"Gleichspannung","zh":"直流电压","cs":"stejnosměrné napětí (DC)"},{"codes":"7.02","pl":"prąd DC","en":"DC current","de":"DC-Strom","zh":"直流电流","cs":"proud DC"},{"codes":"7.03","pl":"napięcie AC","en":"AC voltage","de":"AC-Spannung","zh":"交流电压","cs":"napětí AC"},{"codes":"7.04","pl":"prąd AC","en":"AC current","de":"AC-Strom","zh":"交流电流","cs":"proud AC"},{"codes":"7.05","pl":"rezystancja DC","en":"DC resistance","de":"DC-Widerstand","zh":"直流电阻","cs":"odpor DC"},{"codes":"7.06","pl":"rezystancja AC","en":"AC resistance","de":"Wechselstromwiderstand","zh":"交流电阻","cs":"střídavý odpor"},{"codes":"7.14","pl":"wysokie napięcie i prąd","en":"high voltage and current","de":"Hochspannung und Strom","zh":"高电压和大电流","cs":"vysoké napětí a proud"},{"codes":"10.01","pl":"czas (przedział czasu)","en":"time (time interval)","de":"Zeit (Zeitintervall)","zh":"时间（时间间隔）","cs":"čas (časový interval)"},{"codes":"10.02","pl":"częstotliwość","en":"frequency","de":"Frequenz","zh":"频率","cs":"frekvence"}],"has_en":true,"has_zh":true,"issue":{"no":"11","date":"09.07.2026"},"issue_date":"09.07.2026","issue_number":"11","lab_division":"Laboratorium Pomiarowe","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[19.0898962,50.301787]},"map_coord":[50.301787,19.0898962],"map_geo":"nominatim-street","methods_count":19,"name":"STEMAD s.c. Weronika Madej, Andrzej Madej","parse_date":"2026-11-13T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-13T12:00:00.000Z","pdf_files":["AP_165.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: napięcie DC, prąd DC, napięcie AC, prąd AC, rezystancja DC, rezystancja AC, wysokie napięcie i prąd, czas (przedział czasu), częstotliwość. W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"stemad s.c. weronika madej, andrzej madej laboratorium pomiarowe ul. 3 kwietnia 21, 41-253 czeladź laboratorium wzorcujące. wielkości mierzone: napięcie dc, prąd dc, napięcie ac, prąd ac, rezystancja dc, rezystancja ac, wysokie napięcie i prąd, czas (przedział czasu), częstotliwość. w stałej lokalizacji (s) i/lub poza nią (p). ap 165 ap165 laboratorium wzorcujące wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance ac resistance high voltage and current time (time interval) frequency stemad s.c. weronika madej, andrzej madej laboratorium pomiarowe ul. 3 kwietnia 21, 41-253 czeladz laboratorium wzorcujace. wielkosci mierzone: napiecie dc, prad dc, napiecie ac, prad ac, rezystancja dc, rezystancja ac, wysokie napiecie i prad, czas (przedzial czasu), czestotliwosc. w stalej lokalizacji (s) i/lub poza nia (p). ap 165 ap165 laboratorium wzorcujace wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance ac resistance high voltage and current time (time interval) frequency","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20165,podmiot.html","source_pdf_sha256":"7c9d338f469cab3a9f147c7aa82231bdf27afbb01d06e4092774524256e0fb14","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/13/abdc2fefaf16fd4f59f5cdd787f625e4/AP%20165.pdf","status":"active","updated_at":"2026-11-13T12:00:00.000Z","valid_from":"10-08-2016","valid_until":"09-08-2028","website":"www.stemad.pl","lab_division_en":"Measurement Laboratory","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Messlabor","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"测量实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Měřicí laboratoř","pelny_cs":true},"methods":[{"_id":"5995ec1ef725f6415c22601d","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Generatory\nKalibratory\nKarty pomiarowe\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry\nOscyloskopy\nZasilacze","test_object_en":"Generators\nCalibrators\nData acquisition cards\nAnalogue voltmeters\nDigital voltmeters\nMultimeters\nOscilloscopes\nPower supplies","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0 mV do 10 mV","cmc":"0,5 µV"},{"name":"","range":"10 mV do 120 mV","cmc":"1,3·10⁻⁵ · U + 0,2 µV"},{"name":"","range":"0,12 V do 1,2 V","cmc":"1·10⁻⁵ · U + 0,7 µV"},{"name":"","range":"1,2 V do 12 V","cmc":"1·10⁻⁵ · U + 7 µV"},{"name":"","range":"12 V do 120 V","cmc":"1,2·10⁻⁵ · U + 0,09 mV"},{"name":"","range":"120 V do 1050 V","cmc":"1,2·10⁻⁵ · U + 1,4 mV"}],"parameters_en":[{"name":"","range":"0 mV to 10 mV","cmc":"0,5 µV"},{"name":"","range":"10 mV to 120 mV","cmc":"1,3·10⁻⁵ · U + 0,2 µV"},{"name":"","range":"0,12 V to 1,2 V","cmc":"1·10⁻⁵ · U + 0,7 µV"},{"name":"","range":"1,2 V to 12 V","cmc":"1·10⁻⁵ · U + 7 µV"},{"name":"","range":"12 V to 120 V","cmc":"1,2·10⁻⁵ · U + 0,09 mV"},{"name":"","range":"120 V to 1050 V","cmc":"1,2·10⁻⁵ · U + 1,4 mV"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0 mV do 10 mV CMC 0,5 µV\n10 mV do 120 mV CMC 1,3·10⁻⁵ · U + 0,2 µV\n0,12 V do 1,2 V CMC 1·10⁻⁵ · U + 0,7 µV\n1,2 V do 12 V CMC 1·10⁻⁵ · U + 7 µV\n12 V do 120 V CMC 1,2·10⁻⁵ · U + 0,09 mV\n120 V do 1050 V CMC 1,2·10⁻⁵ · U + 1,4 mV\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-04 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-04","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Generatory\nKalibratory\nKarty pomiarowe\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry\nOscyloskopy\nZasilacze Wzorcowanie — Napięcie DC\nZakres:\n0 mV do 10 mV CMC 0,5 µV\n10 mV do 120 mV CMC 1,3·10⁻⁵ · U + 0,2 µV\n0,12 V do 1,2 V CMC 1·10⁻⁵ · U + 0,7 µV\n1,2 V do 12 V CMC 1·10⁻⁵ · U + 7 µV\n12 V do 120 V CMC 1,2·10⁻⁵ · U + 0,09 mV\n120 V do 1050 V CMC 1,2·10⁻⁵ · U + 1,4 mV\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PW-04 w oparciu o EURAMET cg-15 v.3.0 Generatory\nKalibratory\nKarty pomiarowe\nMierniki napiecia analogowe\nMierniki napiecia cyfrowe\nMultimetry\nOscyloskopy\nZasilacze Wzorcowanie — Napiecie DC\nZakres:\n0 mV do 10 mV CMC 0,5 µV\n10 mV do 120 mV CMC 1,3·10⁻⁵ · U + 0,2 µV\n0,12 V do 1,2 V CMC 1·10⁻⁵ · U + 0,7 µV\n1,2 V do 12 V CMC 1·10⁻⁵ · U + 7 µV\n12 V do 120 V CMC 1,2·10⁻⁵ · U + 0,09 mV\n120 V do 1050 V CMC 1,2·10⁻⁵ · U + 1,4 mV\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PW-04 w oparciu o EURAMET cg-15 v.3.0","search_en":"Generators Calibrators Data acquisition cards Analogue voltmeters Digital voltmeters Multimeters Oscilloscopes Power supplies Calibration — DC voltage Internal procedure; At permanent location (S) and outside of it (P) DC voltage Internal procedure At permanent location (S) and outside of it (P) PW-04 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-04 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0 mV to 10 mV","cmc":"0,5 µV"},{"name":"","range":"10 mV to 120 mV","cmc":"1,3·10⁻⁵ · U + 0,2 µV"},{"name":"","range":"0,12 V to 1,2 V","cmc":"1·10⁻⁵ · U + 0,7 µV"},{"name":"","range":"1,2 V to 12 V","cmc":"1·10⁻⁵ · U + 7 µV"},{"name":"","range":"12 V to 120 V","cmc":"1,2·10⁻⁵ · U + 0,09 mV"},{"name":"","range":"120 V to 1050 V","cmc":"1,2·10⁻⁵ · U + 1,4 mV"}],"reference_de":"PW-04 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"DC-Spannung","search_de":"Generatoren Kalibratoren Messkarten Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte Multimeter Oszilloskope Netzgeräte Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) DC-Spannung Internes Verfahren Am festen Standort (S) und außerhalb (P) PW-04 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Generatoren\nKalibratoren\nMesskarten\nAnaloge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\nMultimeter\nOszilloskope\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0 mV to 10 mV","cmc":"0,5 µV"},{"name":"","range":"10 mV to 120 mV","cmc":"1,3·10⁻⁵ · U + 0,2 µV"},{"name":"","range":"0,12 V to 1,2 V","cmc":"1·10⁻⁵ · U + 0,7 µV"},{"name":"","range":"1,2 V to 12 V","cmc":"1·10⁻⁵ · U + 7 µV"},{"name":"","range":"12 V to 120 V","cmc":"1,2·10⁻⁵ · U + 0,09 mV"},{"name":"","range":"120 V to 1050 V","cmc":"1,2·10⁻⁵ · U + 1,4 mV"}],"reference_zh":"PW-04 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"直流电压","search_zh":"发生器 校准器 测量卡 模拟电压表 数字电压表 万用表 示波器 电源 校准 — 直流电压 内部程序；在固定地点 (S) 及固定地点以外 (P) 直流电压 内部程序 在固定地点 (S) 及固定地点以外 (P) PW-04 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"发生器\n校准器\n测量卡\n模拟电压表\n数字电压表\n万用表\n示波器\n电源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0 mV to 10 mV","cmc":"0,5 µV"},{"name":"","range":"10 mV to 120 mV","cmc":"1,3·10⁻⁵ · U + 0,2 µV"},{"name":"","range":"0,12 V to 1,2 V","cmc":"1·10⁻⁵ · U + 0,7 µV"},{"name":"","range":"1,2 V to 12 V","cmc":"1·10⁻⁵ · U + 7 µV"},{"name":"","range":"12 V to 120 V","cmc":"1,2·10⁻⁵ · U + 0,09 mV"},{"name":"","range":"120 V to 1050 V","cmc":"1,2·10⁻⁵ · U + 1,4 mV"}],"reference_cs":"PW-04 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Napětí DC","search_cs":"Generátory Kalibrátory Měřicí karty Analogové měřiče napětí Digitální měřiče napětí Multimetry Osciloskopy Napájecí zdroje Kalibrace — Napětí DC Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Napětí DC Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) PW-04 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Generátory\nKalibrátory\nMěřicí karty\nAnalogové měřiče napětí\nDigitální měřiče napětí\nMultimetry\nOsciloskopy\nNapájecí zdroje"},{"_id":"35ad6caff4085e8e1490e6f0","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Mierniki napięcia przebicia\nPróbniki przebicia\nZasilacze","test_object_en":"Breakdown voltage meters\nBreakdown testers\nPower supplies","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0,01 kV do 40 kV","cmc":"1·10⁻³ · U"}],"parameters_en":[{"name":"","range":"0,01 kV to 40 kV","cmc":"1·10⁻³ · U"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\n0,01 kV do 40 kV CMC 1·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-06","norm_bases":["PW-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Mierniki napięcia przebicia\nPróbniki przebicia\nZasilacze Wzorcowanie — Napięcie DC\n0,01 kV do 40 kV CMC 1·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) PW-06 Mierniki napiecia przebicia\nProbniki przebicia\nZasilacze Wzorcowanie — Napiecie DC\n0,01 kV do 40 kV CMC 1·10⁻³ · U\nProcedura wewnetrzna; metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) PW-06","search_en":"Breakdown voltage meters Breakdown testers Power supplies Calibration — DC voltage Internal procedure; direct method; At permanent location (S) and outside of it (P) DC voltage Internal procedure direct method At permanent location (S) and outside of it (P) PW-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0,01 kV to 40 kV","cmc":"1·10⁻³ · U"}],"regulatory_area_de":"DC-Spannung","search_de":"Durchschlagspannungsmessgeräte Durchschlagprüfgeräte Netzgeräte Kalibrierung — DC-Spannung Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Spannung Internes Verfahren direktes Verfahren Am festen Standort (S) und außerhalb (P) PW-06","technique_de":"Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Durchschlagspannungsmessgeräte\nDurchschlagprüfgeräte\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0,01 kV to 40 kV","cmc":"1·10⁻³ · U"}],"regulatory_area_zh":"直流电压","search_zh":"击穿电压测量仪 击穿测试仪 电源 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) PW-06","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"击穿电压测量仪\n击穿测试仪\n电源","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0,01 kV to 40 kV","cmc":"1·10⁻³ · U"}],"regulatory_area_cs":"Napětí DC","search_cs":"Měřiče průrazného napětí Zkoušečky průrazu Napájecí zdroje Kalibrace — Napětí DC Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí DC Vnitřní postup přímá metoda V trvalé lokalitě (S) i mimo ni (P) PW-06","technique_cs":"Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče průrazného napětí\nZkoušečky průrazu\nNapájecí zdroje"},{"_id":"33f8371330ebd0de0a2c1082","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Kalibratory\nKarty pomiarowe\nMierniki cęgowe\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry\nSondy pomiarowe\nZasilacze","test_object_en":"Calibrators\nData acquisition cards\nClamp meters\nAnalogue ammeters\nDigital ammeters\nMultimeters\nMeasuring probes\nPower supplies","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"10 µA do 120 µA","cmc":"3·10⁻⁵ · I + 1 nA"},{"name":"","range":"0,12 mA do 1,2 mA","cmc":"2·10⁻⁵ · I + 5 nA"},{"name":"","range":"1,2 mA do 12 mA","cmc":"3·10⁻⁵ · I + 0,05 µA"},{"name":"","range":"12 mA do 120 mA","cmc":"2·10⁻⁵ · I + 0,2 µA"},{"name":"","range":"0,12 A do 1,05 A","cmc":"2·10⁻⁴ · I + 15 µA"},{"name":"","range":"1,05 A do 120 A","cmc":"7,5·10⁻⁵ · I + 1 mA"},{"name":"","range":"120 A do 600 A","cmc":"7,5·10⁻⁵ · I + 5 mA"},{"name":"","range":"600 A do 1200 A","cmc":"1·10⁻⁴ · I + 10 mA"}],"parameters_en":[{"name":"","range":"10 µA to 120 µA","cmc":"3·10⁻⁵ · I + 1 nA"},{"name":"","range":"0,12 mA to 1,2 mA","cmc":"2·10⁻⁵ · I + 5 nA"},{"name":"","range":"1,2 mA to 12 mA","cmc":"3·10⁻⁵ · I + 0,05 µA"},{"name":"","range":"12 mA to 120 mA","cmc":"2·10⁻⁵ · I + 0,2 µA"},{"name":"","range":"0,12 A to 1,05 A","cmc":"2·10⁻⁴ · I + 15 µA"},{"name":"","range":"1,05 A to 120 A","cmc":"7,5·10⁻⁵ · I + 1 mA"},{"name":"","range":"120 A to 600 A","cmc":"7,5·10⁻⁵ · I + 5 mA"},{"name":"","range":"600 A to 1200 A","cmc":"1·10⁻⁴ · I + 10 mA"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n10 µA do 120 µA CMC 3·10⁻⁵ · I + 1 nA\n0,12 mA do 1,2 mA CMC 2·10⁻⁵ · I + 5 nA\n1,2 mA do 12 mA CMC 3·10⁻⁵ · I + 0,05 µA\n12 mA do 120 mA CMC 2·10⁻⁵ · I + 0,2 µA\n0,12 A do 1,05 A CMC 2·10⁻⁴ · I + 15 µA\n1,05 A do 120 A CMC 7,5·10⁻⁵ · I + 1 mA\n120 A do 600 A CMC 7,5·10⁻⁵ · I + 5 mA\n600 A do 1200 A CMC 1·10⁻⁴ · I + 10 mA\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-04 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-04","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Kalibratory\nKarty pomiarowe\nMierniki cęgowe\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry\nSondy pomiarowe\nZasilacze Wzorcowanie — Prąd DC\nZakres:\n10 µA do 120 µA CMC 3·10⁻⁵ · I + 1 nA\n0,12 mA do 1,2 mA CMC 2·10⁻⁵ · I + 5 nA\n1,2 mA do 12 mA CMC 3·10⁻⁵ · I + 0,05 µA\n12 mA do 120 mA CMC 2·10⁻⁵ · I + 0,2 µA\n0,12 A do 1,05 A CMC 2·10⁻⁴ · I + 15 µA\n1,05 A do 120 A CMC 7,5·10⁻⁵ · I + 1 mA\n120 A do 600 A CMC 7,5·10⁻⁵ · I + 5 mA\n600 A do 1200 A CMC 1·10⁻⁴ · I + 10 mA\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PW-04 w oparciu o EURAMET cg-15 v.3.0 Kalibratory\nKarty pomiarowe\nMierniki cegowe\nMierniki pradu analogowe\nMierniki pradu cyfrowe\nMultimetry\nSondy pomiarowe\nZasilacze Wzorcowanie — Prad DC\nZakres:\n10 µA do 120 µA CMC 3·10⁻⁵ · I + 1 nA\n0,12 mA do 1,2 mA CMC 2·10⁻⁵ · I + 5 nA\n1,2 mA do 12 mA CMC 3·10⁻⁵ · I + 0,05 µA\n12 mA do 120 mA CMC 2·10⁻⁵ · I + 0,2 µA\n0,12 A do 1,05 A CMC 2·10⁻⁴ · I + 15 µA\n1,05 A do 120 A CMC 7,5·10⁻⁵ · I + 1 mA\n120 A do 600 A CMC 7,5·10⁻⁵ · I + 5 mA\n600 A do 1200 A CMC 1·10⁻⁴ · I + 10 mA\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PW-04 w oparciu o EURAMET cg-15 v.3.0","search_en":"Calibrators Data acquisition cards Clamp meters Analogue ammeters Digital ammeters Multimeters Measuring probes Power supplies Calibration — DC current Internal procedure; At permanent location (S) and outside of it (P) DC current Internal procedure At permanent location (S) and outside of it (P) PW-04 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-04 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"10 µA to 120 µA","cmc":"3·10⁻⁵ · I + 1 nA"},{"name":"","range":"0,12 mA to 1,2 mA","cmc":"2·10⁻⁵ · I + 5 nA"},{"name":"","range":"1,2 mA to 12 mA","cmc":"3·10⁻⁵ · I + 0,05 µA"},{"name":"","range":"12 mA to 120 mA","cmc":"2·10⁻⁵ · I + 0,2 µA"},{"name":"","range":"0,12 A to 1,05 A","cmc":"2·10⁻⁴ · I + 15 µA"},{"name":"","range":"1,05 A to 120 A","cmc":"7,5·10⁻⁵ · I + 1 mA"},{"name":"","range":"120 A to 600 A","cmc":"7,5·10⁻⁵ · I + 5 mA"},{"name":"","range":"600 A to 1200 A","cmc":"1·10⁻⁴ · I + 10 mA"}],"reference_de":"PW-04 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"DC-Strom","search_de":"Kalibratoren Messkarten Zangenmessgeräte Analoge Strommessgeräte Digitale Strommessgeräte Multimeter Messsonden Netzgeräte Kalibrierung — DC-Strom Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) DC-Strom Internes Verfahren Am festen Standort (S) und außerhalb (P) PW-04 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nMesskarten\nZangenmessgeräte\nAnaloge Strommessgeräte\nDigitale Strommessgeräte\nMultimeter\nMesssonden\nNetzgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"10 µA to 120 µA","cmc":"3·10⁻⁵ · I + 1 nA"},{"name":"","range":"0,12 mA to 1,2 mA","cmc":"2·10⁻⁵ · I + 5 nA"},{"name":"","range":"1,2 mA to 12 mA","cmc":"3·10⁻⁵ · I + 0,05 µA"},{"name":"","range":"12 mA to 120 mA","cmc":"2·10⁻⁵ · I + 0,2 µA"},{"name":"","range":"0,12 A to 1,05 A","cmc":"2·10⁻⁴ · I + 15 µA"},{"name":"","range":"1,05 A to 120 A","cmc":"7,5·10⁻⁵ · I + 1 mA"},{"name":"","range":"120 A to 600 A","cmc":"7,5·10⁻⁵ · I + 5 mA"},{"name":"","range":"600 A to 1200 A","cmc":"1·10⁻⁴ · I + 10 mA"}],"reference_zh":"PW-04 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"直流电流","search_zh":"校准器 测量卡 钳形表 模拟电流表 数字电流表 万用表 测量探头 电源 校准 — 直流电流 内部程序；在固定地点 (S) 及固定地点以外 (P) 直流电流 内部程序 在固定地点 (S) 及固定地点以外 (P) PW-04 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n测量卡\n钳形表\n模拟电流表\n数字电流表\n万用表\n测量探头\n电源","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"10 µA to 120 µA","cmc":"3·10⁻⁵ · I + 1 nA"},{"name":"","range":"0,12 mA to 1,2 mA","cmc":"2·10⁻⁵ · I + 5 nA"},{"name":"","range":"1,2 mA to 12 mA","cmc":"3·10⁻⁵ · I + 0,05 µA"},{"name":"","range":"12 mA to 120 mA","cmc":"2·10⁻⁵ · I + 0,2 µA"},{"name":"","range":"0,12 A to 1,05 A","cmc":"2·10⁻⁴ · I + 15 µA"},{"name":"","range":"1,05 A to 120 A","cmc":"7,5·10⁻⁵ · I + 1 mA"},{"name":"","range":"120 A to 600 A","cmc":"7,5·10⁻⁵ · I + 5 mA"},{"name":"","range":"600 A to 1200 A","cmc":"1·10⁻⁴ · I + 10 mA"}],"reference_cs":"PW-04 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Proud DC","search_cs":"Kalibrátory Měřicí karty Klešťové měřiče Analogové měřiče proudu Digitální měřiče proudu Multimetry Měřicí sondy Napájecí zdroje Kalibrace — Proud DC Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Proud DC Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) PW-04 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nMěřicí karty\nKlešťové měřiče\nAnalogové měřiče proudu\nDigitální měřiče proudu\nMultimetry\nMěřicí sondy\nNapájecí zdroje"},{"_id":"34fa34f7d1b284fbf7ea6324","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Generatory\nKalibratory\nKarty pomiarowe\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry\nZasilacze","test_object_en":"Generators\nCalibrators\nData acquisition cards\nAnalogue voltmeters\nDigital voltmeters\nMultimeters\nPower supplies","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"40 Hz do 1 kHz","range":"1 mV do 12 mV","cmc":"4·10⁻⁴ · U + 3 µV"},{"name":"40 Hz do 1 kHz","range":"12 mV do 120 mV","cmc":"2·10⁻⁴ · U + 3 µV"},{"name":"40 Hz do 1 kHz","range":"0,12 V do 1,2 V","cmc":"1,2·10⁻⁴ · U + 0,03 mV"},{"name":"40 Hz do 1 kHz","range":"1,2 V do 12 V","cmc":"1,2·10⁻⁴ · U + 0,3 mV"},{"name":"40 Hz do 1 kHz","range":"12 V do 120 V","cmc":"3·10⁻⁴ · U + 2 mV"},{"name":"40 Hz do 1 kHz","range":"120 V do 1050 V","cmc":"5,5·10⁻⁴ · U + 0,05 V"},{"name":"1 kHz do 20 kHz","range":"1 mV do 12 mV","cmc":"5·10⁻⁴ · U + 3 µV"},{"name":"1 kHz do 20 kHz","range":"12 mV do 120 mV","cmc":"3·10⁻⁴ · U + 3 µV"},{"name":"1 kHz do 20 kHz","range":"0,12 V do 1,2 V","cmc":"3·10⁻⁴ · U + 0,02 mV"},{"name":"1 kHz do 20 kHz","range":"1,2 V do 12 V","cmc":"3·10⁻⁴ · U + 0,2 mV"},{"name":"1 kHz do 20 kHz","range":"12 V do 120 V","cmc":"3·10⁻⁴ · U + 3 mV"},{"name":"1 kHz do 20 kHz","range":"120 V do 700 V","cmc":"8·10⁻⁴ · U + 40 mV"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"1 mV to 12 mV","cmc":"4·10⁻⁴ · U + 3 µV"},{"name":"40 Hz to 1 kHz","range":"12 mV to 120 mV","cmc":"2·10⁻⁴ · U + 3 µV"},{"name":"40 Hz to 1 kHz","range":"0,12 V to 1,2 V","cmc":"1,2·10⁻⁴ · U + 0,03 mV"},{"name":"40 Hz to 1 kHz","range":"1,2 V to 12 V","cmc":"1,2·10⁻⁴ · U + 0,3 mV"},{"name":"40 Hz to 1 kHz","range":"12 V to 120 V","cmc":"3·10⁻⁴ · U + 2 mV"},{"name":"40 Hz to 1 kHz","range":"120 V to 1050 V","cmc":"5,5·10⁻⁴ · U + 0,05 V"},{"name":"1 kHz to 20 kHz","range":"1 mV to 12 mV","cmc":"5·10⁻⁴ · U + 3 µV"},{"name":"1 kHz to 20 kHz","range":"12 mV to 120 mV","cmc":"3·10⁻⁴ · U + 3 µV"},{"name":"1 kHz to 20 kHz","range":"0,12 V to 1,2 V","cmc":"3·10⁻⁴ · U + 0,02 mV"},{"name":"1 kHz to 20 kHz","range":"1,2 V to 12 V","cmc":"3·10⁻⁴ · U + 0,2 mV"},{"name":"1 kHz to 20 kHz","range":"12 V to 120 V","cmc":"3·10⁻⁴ · U + 3 mV"},{"name":"1 kHz to 20 kHz","range":"120 V to 700 V","cmc":"8·10⁻⁴ · U + 40 mV"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 1 kHz 1 mV do 12 mV CMC 4·10⁻⁴ · U + 3 µV\n40 Hz do 1 kHz 12 mV do 120 mV CMC 2·10⁻⁴ · U + 3 µV\n40 Hz do 1 kHz 0,12 V do 1,2 V CMC 1,2·10⁻⁴ · U + 0,03 mV\n40 Hz do 1 kHz 1,2 V do 12 V CMC 1,2·10⁻⁴ · U + 0,3 mV\n40 Hz do 1 kHz 12 V do 120 V CMC 3·10⁻⁴ · U + 2 mV\n40 Hz do 1 kHz 120 V do 1050 V CMC 5,5·10⁻⁴ · U + 0,05 V\n1 kHz do 20 kHz 1 mV do 12 mV CMC 5·10⁻⁴ · U + 3 µV\n1 kHz do 20 kHz 12 mV do 120 mV CMC 3·10⁻⁴ · U + 3 µV\n1 kHz do 20 kHz 0,12 V do 1,2 V CMC 3·10⁻⁴ · U + 0,02 mV\n1 kHz do 20 kHz 1,2 V do 12 V CMC 3·10⁻⁴ · U + 0,2 mV\n1 kHz do 20 kHz 12 V do 120 V CMC 3·10⁻⁴ · U + 3 mV\n1 kHz do 20 kHz 120 V do 700 V CMC 8·10⁻⁴ · U + 40 mV\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-04 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-04","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Generatory\nKalibratory\nKarty pomiarowe\nMierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry\nZasilacze Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 1 kHz 1 mV do 12 mV CMC 4·10⁻⁴ · U + 3 µV\n40 Hz do 1 kHz 12 mV do 120 mV CMC 2·10⁻⁴ · U + 3 µV\n40 Hz do 1 kHz 0,12 V do 1,2 V CMC 1,2·10⁻⁴ · U + 0,03 mV\n40 Hz do 1 kHz 1,2 V do 12 V CMC 1,2·10⁻⁴ · U + 0,3 mV\n40 Hz do 1 kHz 12 V do 120 V CMC 3·10⁻⁴ · U + 2 mV\n40 Hz do 1 kHz 120 V do 1050 V CMC 5,5·10⁻⁴ · U + 0,05 V\n1 kHz do 20 kHz 1 mV do 12 mV CMC 5·10⁻⁴ · U + 3 µV\n1 kHz do 20 kHz 12 mV do 120 mV CMC 3·10⁻⁴ · U + 3 µV\n1 kHz do 20 kHz 0,12 V do 1,2 V CMC 3·10⁻⁴ · U + 0,02 mV\n1 kHz do 20 kHz 1,2 V do 12 V CMC 3·10⁻⁴ · U + 0,2 mV\n1 kHz do 20 kHz 12 V do 120 V CMC 3·10⁻⁴ · U + 3 mV\n1 kHz do 20 kHz 120 V do 700 V CMC 8·10⁻⁴ · U + 40 mV\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PW-04 w oparciu o EURAMET cg-15 v.3.0 Generatory\nKalibratory\nKarty pomiarowe\nMierniki napiecia analogowe\nMierniki napiecia cyfrowe\nMultimetry\nZasilacze Wzorcowanie — Napiecie AC\nZakres:\n40 Hz do 1 kHz 1 mV do 12 mV CMC 4·10⁻⁴ · U + 3 µV\n40 Hz do 1 kHz 12 mV do 120 mV CMC 2·10⁻⁴ · U + 3 µV\n40 Hz do 1 kHz 0,12 V do 1,2 V CMC 1,2·10⁻⁴ · U + 0,03 mV\n40 Hz do 1 kHz 1,2 V do 12 V CMC 1,2·10⁻⁴ · U + 0,3 mV\n40 Hz do 1 kHz 12 V do 120 V CMC 3·10⁻⁴ · U + 2 mV\n40 Hz do 1 kHz 120 V do 1050 V CMC 5,5·10⁻⁴ · U + 0,05 V\n1 kHz do 20 kHz 1 mV do 12 mV CMC 5·10⁻⁴ · U + 3 µV\n1 kHz do 20 kHz 12 mV do 120 mV CMC 3·10⁻⁴ · U + 3 µV\n1 kHz do 20 kHz 0,12 V do 1,2 V CMC 3·10⁻⁴ · U + 0,02 mV\n1 kHz do 20 kHz 1,2 V do 12 V CMC 3·10⁻⁴ · U + 0,2 mV\n1 kHz do 20 kHz 12 V do 120 V CMC 3·10⁻⁴ · U + 3 mV\n1 kHz do 20 kHz 120 V do 700 V CMC 8·10⁻⁴ · U + 40 mV\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PW-04 w oparciu o EURAMET cg-15 v.3.0","search_en":"Generators Calibrators Data acquisition cards Analogue voltmeters Digital voltmeters Multimeters Power supplies Calibration — AC voltage Internal procedure; At permanent location (S) and outside of it (P) AC voltage Internal procedure At permanent location (S) and outside of it (P) 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz 1 kHz to 20 kHz 1 kHz to 20 kHz 1 kHz to 20 kHz 1 kHz to 20 kHz 1 kHz to 20 kHz 1 kHz to 20 kHz PW-04 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-04 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"40 Hz bis 1 kHz","range":"1 mV to 12 mV","cmc":"4·10⁻⁴ · U + 3 µV"},{"name":"40 Hz bis 1 kHz","range":"12 mV to 120 mV","cmc":"2·10⁻⁴ · U + 3 µV"},{"name":"40 Hz bis 1 kHz","range":"0,12 V to 1,2 V","cmc":"1,2·10⁻⁴ · U + 0,03 mV"},{"name":"40 Hz bis 1 kHz","range":"1,2 V to 12 V","cmc":"1,2·10⁻⁴ · U + 0,3 mV"},{"name":"40 Hz bis 1 kHz","range":"12 V to 120 V","cmc":"3·10⁻⁴ · U + 2 mV"},{"name":"40 Hz bis 1 kHz","range":"120 V to 1050 V","cmc":"5,5·10⁻⁴ · U + 0,05 V"},{"name":"1 kHz bis 20 kHz","range":"1 mV to 12 mV","cmc":"5·10⁻⁴ · U + 3 µV"},{"name":"1 kHz bis 20 kHz","range":"12 mV to 120 mV","cmc":"3·10⁻⁴ · U + 3 µV"},{"name":"1 kHz bis 20 kHz","range":"0,12 V to 1,2 V","cmc":"3·10⁻⁴ · U + 0,02 mV"},{"name":"1 kHz bis 20 kHz","range":"1,2 V to 12 V","cmc":"3·10⁻⁴ · U + 0,2 mV"},{"name":"1 kHz bis 20 kHz","range":"12 V to 120 V","cmc":"3·10⁻⁴ · U + 3 mV"},{"name":"1 kHz bis 20 kHz","range":"120 V to 700 V","cmc":"8·10⁻⁴ · U + 40 mV"}],"reference_de":"PW-04 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"AC-Spannung","search_de":"Generatoren Kalibratoren Messkarten Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte Multimeter Netzgeräte Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren Am festen Standort (S) und außerhalb (P) 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 40 Hz bis 1 kHz 1 kHz bis 20 kHz 1 kHz bis 20 kHz 1 kHz bis 20 kHz 1 kHz bis 20 kHz 1 kHz bis 20 kHz 1 kHz bis 20 kHz PW-04 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Generatoren\nKalibratoren\nMesskarten\nAnaloge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\nMultimeter\nNetzgeräte","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"1 mV to 12 mV","cmc":"4·10⁻⁴ · U + 3 µV"},{"name":"40 Hz 至 1 kHz","range":"12 mV to 120 mV","cmc":"2·10⁻⁴ · U + 3 µV"},{"name":"40 Hz 至 1 kHz","range":"0,12 V to 1,2 V","cmc":"1,2·10⁻⁴ · U + 0,03 mV"},{"name":"40 Hz 至 1 kHz","range":"1,2 V to 12 V","cmc":"1,2·10⁻⁴ · U + 0,3 mV"},{"name":"40 Hz 至 1 kHz","range":"12 V to 120 V","cmc":"3·10⁻⁴ · U + 2 mV"},{"name":"40 Hz 至 1 kHz","range":"120 V to 1050 V","cmc":"5,5·10⁻⁴ · U + 0,05 V"},{"name":"1 kHz 至 20 kHz","range":"1 mV to 12 mV","cmc":"5·10⁻⁴ · U + 3 µV"},{"name":"1 kHz 至 20 kHz","range":"12 mV to 120 mV","cmc":"3·10⁻⁴ · U + 3 µV"},{"name":"1 kHz 至 20 kHz","range":"0,12 V to 1,2 V","cmc":"3·10⁻⁴ · U + 0,02 mV"},{"name":"1 kHz 至 20 kHz","range":"1,2 V to 12 V","cmc":"3·10⁻⁴ · U + 0,2 mV"},{"name":"1 kHz 至 20 kHz","range":"12 V to 120 V","cmc":"3·10⁻⁴ · U + 3 mV"},{"name":"1 kHz 至 20 kHz","range":"120 V to 700 V","cmc":"8·10⁻⁴ · U + 40 mV"}],"reference_zh":"PW-04 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"交流电压","search_zh":"发生器 校准器 测量卡 模拟电压表 数字电压表 万用表 电源 校准 — 交流电压 内部程序；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 在固定地点 (S) 及固定地点以外 (P) 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 40 Hz 至 1 kHz 1 kHz 至 20 kHz 1 kHz 至 20 kHz 1 kHz 至 20 kHz 1 kHz 至 20 kHz 1 kHz 至 20 kHz 1 kHz 至 20 kHz PW-04 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"发生器\n校准器\n测量卡\n模拟电压表\n数字电压表\n万用表\n电源","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"40 Hz až 1 kHz","range":"1 mV to 12 mV","cmc":"4·10⁻⁴ · U + 3 µV"},{"name":"40 Hz až 1 kHz","range":"12 mV to 120 mV","cmc":"2·10⁻⁴ · U + 3 µV"},{"name":"40 Hz až 1 kHz","range":"0,12 V to 1,2 V","cmc":"1,2·10⁻⁴ · U + 0,03 mV"},{"name":"40 Hz až 1 kHz","range":"1,2 V to 12 V","cmc":"1,2·10⁻⁴ · U + 0,3 mV"},{"name":"40 Hz až 1 kHz","range":"12 V to 120 V","cmc":"3·10⁻⁴ · U + 2 mV"},{"name":"40 Hz až 1 kHz","range":"120 V to 1050 V","cmc":"5,5·10⁻⁴ · U + 0,05 V"},{"name":"1 kHz až 20 kHz","range":"1 mV to 12 mV","cmc":"5·10⁻⁴ · U + 3 µV"},{"name":"1 kHz až 20 kHz","range":"12 mV to 120 mV","cmc":"3·10⁻⁴ · U + 3 µV"},{"name":"1 kHz až 20 kHz","range":"0,12 V to 1,2 V","cmc":"3·10⁻⁴ · U + 0,02 mV"},{"name":"1 kHz až 20 kHz","range":"1,2 V to 12 V","cmc":"3·10⁻⁴ · U + 0,2 mV"},{"name":"1 kHz až 20 kHz","range":"12 V to 120 V","cmc":"3·10⁻⁴ · U + 3 mV"},{"name":"1 kHz až 20 kHz","range":"120 V to 700 V","cmc":"8·10⁻⁴ · U + 40 mV"}],"reference_cs":"PW-04 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Napětí AC","search_cs":"Generátory Kalibrátory Měřicí karty Analogové měřiče napětí Digitální měřiče napětí Multimetry Napájecí zdroje Kalibrace — Napětí AC Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 40 Hz až 1 kHz 1 kHz až 20 kHz 1 kHz až 20 kHz 1 kHz až 20 kHz 1 kHz až 20 kHz 1 kHz až 20 kHz 1 kHz až 20 kHz PW-04 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Generátory\nKalibrátory\nMěřicí karty\nAnalogové měřiče napětí\nDigitální měřiče napětí\nMultimetry\nNapájecí zdroje"},{"_id":"75895bfed7b9e72852785711","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Oscyloskopy\nSkopometry","test_object_en":"Oscilloscopes\nScopemeters","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"40 Hz do 20 kHz","range":"0,001 V do 300 V","cmc":"4 · 10⁻³ · U"},{"name":"20 kHz do 125 MHz","range":"0,001 V do 3 V","cmc":"1,7 · 10⁻² · U"}],"parameters_en":[{"name":"40 Hz to 20 kHz","range":"0,001 V to 300 V","cmc":"4 · 10⁻³ · U"},{"name":"20 kHz to 125 MHz","range":"0,001 V to 3 V","cmc":"1,7 · 10⁻² · U"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 20 kHz 0,001 V do 300 V CMC 4 · 10⁻³ · U\n20 kHz do 125 MHz 0,001 V do 3 V CMC 1,7 · 10⁻² · U\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-01 w oparciu o EURAMET cg-7 v.1.0","norm_bases":["PW-01","EURAMET cg-7 v.1.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Oscyloskopy\nSkopometry Wzorcowanie — Napięcie AC\nZakres:\n40 Hz do 20 kHz 0,001 V do 300 V CMC 4 · 10⁻³ · U\n20 kHz do 125 MHz 0,001 V do 3 V CMC 1,7 · 10⁻² · U\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PW-01 w oparciu o EURAMET cg-7 v.1.0 Oscyloskopy\nSkopometry Wzorcowanie — Napiecie AC\nZakres:\n40 Hz do 20 kHz 0,001 V do 300 V CMC 4 · 10⁻³ · U\n20 kHz do 125 MHz 0,001 V do 3 V CMC 1,7 · 10⁻² · U\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PW-01 w oparciu o EURAMET cg-7 v.1.0","search_en":"Oscilloscopes Scopemeters Calibration — AC voltage Internal procedure; At permanent location (S) and outside of it (P) AC voltage Internal procedure At permanent location (S) and outside of it (P) 40 Hz to 20 kHz 20 kHz to 125 MHz PW-01 based on EURAMET cg-7 v.1.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-01 based on EURAMET cg-7 v.1.0","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"40 Hz bis 20 kHz","range":"0,001 V to 300 V","cmc":"4 · 10⁻³ · U"},{"name":"20 kHz bis 125 MHz","range":"0,001 V to 3 V","cmc":"1,7 · 10⁻² · U"}],"reference_de":"PW-01 auf Grundlage von EURAMET cg-7 v.1.0","regulatory_area_de":"AC-Spannung","search_de":"Oszilloskope Scopemeter Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren Am festen Standort (S) und außerhalb (P) 40 Hz bis 20 kHz 20 kHz bis 125 MHz PW-01 auf Grundlage von EURAMET cg-7 v.1.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Oszilloskope\nScopemeter","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"40 Hz 至 20 kHz","range":"0,001 V to 300 V","cmc":"4 · 10⁻³ · U"},{"name":"20 kHz 至 125 MHz","range":"0,001 V to 3 V","cmc":"1,7 · 10⁻² · U"}],"reference_zh":"PW-01 依据EURAMET cg-7 v.1.0","regulatory_area_zh":"交流电压","search_zh":"示波器 手持示波表 校准 — 交流电压 内部程序；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 在固定地点 (S) 及固定地点以外 (P) 40 Hz 至 20 kHz 20 kHz 至 125 MHz PW-01 依据EURAMET cg-7 v.1.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"示波器\n手持示波表","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"40 Hz až 20 kHz","range":"0,001 V to 300 V","cmc":"4 · 10⁻³ · U"},{"name":"20 kHz až 125 MHz","range":"0,001 V to 3 V","cmc":"1,7 · 10⁻² · U"}],"reference_cs":"PW-01 na základě EURAMET cg-7 v.1.0","regulatory_area_cs":"Napětí AC","search_cs":"Osciloskopy Skopmetry Kalibrace — Napětí AC Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) 40 Hz až 20 kHz 20 kHz až 125 MHz PW-01 na základě EURAMET cg-7 v.1.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Osciloskopy\nSkopmetry"},{"_id":"b3bb35a0c135d53e59c1b8a3","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Mierniki napięcia przebicia\nPróbniki przebicia\nZasilacze","test_object_en":"Breakdown voltage meters\nBreakdown testers\nPower supplies","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"50 Hz do 60 Hz","range":"0,01 kV do 40 kV","cmc":"2,5·10⁻³ · U"}],"parameters_en":[{"name":"50 Hz to 60 Hz","range":"0,01 kV to 40 kV","cmc":"2,5·10⁻³ · U"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\n50 Hz do 60 Hz 0,01 kV do 40 kV CMC 2,5·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-06","norm_bases":["PW-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Mierniki napięcia przebicia\nPróbniki przebicia\nZasilacze Wzorcowanie — Napięcie AC\n50 Hz do 60 Hz 0,01 kV do 40 kV CMC 2,5·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) PW-06 Mierniki napiecia przebicia\nProbniki przebicia\nZasilacze Wzorcowanie — Napiecie AC\n50 Hz do 60 Hz 0,01 kV do 40 kV CMC 2,5·10⁻³ · U\nProcedura wewnetrzna; metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) PW-06","search_en":"Breakdown voltage meters Breakdown testers Power supplies Calibration — AC voltage Internal procedure; direct method; At permanent location (S) and outside of it (P) AC voltage Internal procedure direct method At permanent location (S) and outside of it (P) 50 Hz to 60 Hz PW-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"50 Hz bis 60 Hz","range":"0,01 kV to 40 kV","cmc":"2,5·10⁻³ · U"}],"regulatory_area_de":"AC-Spannung","search_de":"Durchschlagspannungsmessgeräte Durchschlagprüfgeräte Netzgeräte Kalibrierung — Wechselspannung Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Spannung Internes Verfahren direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz bis 60 Hz PW-06","technique_de":"Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Durchschlagspannungsmessgeräte\nDurchschlagprüfgeräte\nNetzgeräte","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"50 Hz 至 60 Hz","range":"0,01 kV to 40 kV","cmc":"2,5·10⁻³ · U"}],"regulatory_area_zh":"交流电压","search_zh":"击穿电压测量仪 击穿测试仪 电源 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电压 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 Hz 至 60 Hz PW-06","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"击穿电压测量仪\n击穿测试仪\n电源","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"50 Hz až 60 Hz","range":"0,01 kV to 40 kV","cmc":"2,5·10⁻³ · U"}],"regulatory_area_cs":"Napětí AC","search_cs":"Měřiče průrazného napětí Zkoušečky průrazu Napájecí zdroje Kalibrace — Napětí AC Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Napětí AC Vnitřní postup přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 Hz až 60 Hz PW-06","technique_cs":"Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče průrazného napětí\nZkoušečky průrazu\nNapájecí zdroje"},{"_id":"5f21217674c84208ad1d7ecf","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Kalibratory\nKarty pomiarowe\nMierniki cęgowe\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry\nSondy pomiarowe\nZasilacze","test_object_en":"Calibrators\nData acquisition cards\nClamp meters\nAnalogue ammeters\nDigital ammeters\nMultimeters\nMeasuring probes\nPower supplies","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"50 Hz do 60 Hz","range":"10 µA do 100,5 µA","cmc":"8 · 10⁻⁴ · I + 15 nA"},{"name":"50 Hz do 60 Hz","range":"0,1005 mA do 1,05 mA","cmc":"8 · 10⁻⁴ · I + 0,15 µA"},{"name":"50 Hz do 60 Hz","range":"1,05 mA do 10,5 mA","cmc":"6,2 · 10⁻⁴ · I + 1,5 µA"},{"name":"50 Hz do 60 Hz","range":"10,5 A do 105 mA","cmc":"6,2 · 10⁻⁴ · I + 15 µA"},{"name":"50 Hz do 60 Hz","range":"0,105 A do 1,05 A","cmc":"9 · 10⁻⁴ · I + 0,18 mA"},{"name":"50 Hz do 60 Hz","range":"1,05 A do 30 A","cmc":"2 · 10⁻⁴ · I + 1 mA"},{"name":"50 Hz do 60 Hz","range":"30 A do 300 A","cmc":"2,5 · 10⁻⁴ · I + 1 mA"},{"name":"50 Hz do 60 Hz","range":"300 A do 1200 A","cmc":"2,5 · 10⁻⁴ · I + 0,05 A"}],"parameters_en":[{"name":"50 Hz to 60 Hz","range":"10 µA to 100,5 µA","cmc":"8 · 10⁻⁴ · I + 15 nA"},{"name":"50 Hz to 60 Hz","range":"0,1005 mA to 1,05 mA","cmc":"8 · 10⁻⁴ · I + 0,15 µA"},{"name":"50 Hz to 60 Hz","range":"1,05 mA to 10,5 mA","cmc":"6,2 · 10⁻⁴ · I + 1,5 µA"},{"name":"50 Hz to 60 Hz","range":"10,5 A to 105 mA","cmc":"6,2 · 10⁻⁴ · I + 15 µA"},{"name":"50 Hz to 60 Hz","range":"0,105 A to 1,05 A","cmc":"9 · 10⁻⁴ · I + 0,18 mA"},{"name":"50 Hz to 60 Hz","range":"1,05 A to 30 A","cmc":"2 · 10⁻⁴ · I + 1 mA"},{"name":"50 Hz to 60 Hz","range":"30 A to 300 A","cmc":"2,5 · 10⁻⁴ · I + 1 mA"},{"name":"50 Hz to 60 Hz","range":"300 A to 1200 A","cmc":"2,5 · 10⁻⁴ · I + 0,05 A"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n50 Hz do 60 Hz 10 µA do 100,5 µA CMC 8 · 10⁻⁴ · I + 15 nA\n50 Hz do 60 Hz 0,1005 mA do 1,05 mA CMC 8 · 10⁻⁴ · I + 0,15 µA\n50 Hz do 60 Hz 1,05 mA do 10,5 mA CMC 6,2 · 10⁻⁴ · I + 1,5 µA\n50 Hz do 60 Hz 10,5 A do 105 mA CMC 6,2 · 10⁻⁴ · I + 15 µA\n50 Hz do 60 Hz 0,105 A do 1,05 A CMC 9 · 10⁻⁴ · I + 0,18 mA\n50 Hz do 60 Hz 1,05 A do 30 A CMC 2 · 10⁻⁴ · I + 1 mA\n50 Hz do 60 Hz 30 A do 300 A CMC 2,5 · 10⁻⁴ · I + 1 mA\n50 Hz do 60 Hz 300 A do 1200 A CMC 2,5 · 10⁻⁴ · I + 0,05 A\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-04 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-04","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Kalibratory\nKarty pomiarowe\nMierniki cęgowe\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry\nSondy pomiarowe\nZasilacze Wzorcowanie — Prąd AC\nZakres:\n50 Hz do 60 Hz 10 µA do 100,5 µA CMC 8 · 10⁻⁴ · I + 15 nA\n50 Hz do 60 Hz 0,1005 mA do 1,05 mA CMC 8 · 10⁻⁴ · I + 0,15 µA\n50 Hz do 60 Hz 1,05 mA do 10,5 mA CMC 6,2 · 10⁻⁴ · I + 1,5 µA\n50 Hz do 60 Hz 10,5 A do 105 mA CMC 6,2 · 10⁻⁴ · I + 15 µA\n50 Hz do 60 Hz 0,105 A do 1,05 A CMC 9 · 10⁻⁴ · I + 0,18 mA\n50 Hz do 60 Hz 1,05 A do 30 A CMC 2 · 10⁻⁴ · I + 1 mA\n50 Hz do 60 Hz 30 A do 300 A CMC 2,5 · 10⁻⁴ · I + 1 mA\n50 Hz do 60 Hz 300 A do 1200 A CMC 2,5 · 10⁻⁴ · I + 0,05 A\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PW-04 w oparciu o EURAMET cg-15 v.3.0 Kalibratory\nKarty pomiarowe\nMierniki cegowe\nMierniki pradu analogowe\nMierniki pradu cyfrowe\nMultimetry\nSondy pomiarowe\nZasilacze Wzorcowanie — Prad AC\nZakres:\n50 Hz do 60 Hz 10 µA do 100,5 µA CMC 8 · 10⁻⁴ · I + 15 nA\n50 Hz do 60 Hz 0,1005 mA do 1,05 mA CMC 8 · 10⁻⁴ · I + 0,15 µA\n50 Hz do 60 Hz 1,05 mA do 10,5 mA CMC 6,2 · 10⁻⁴ · I + 1,5 µA\n50 Hz do 60 Hz 10,5 A do 105 mA CMC 6,2 · 10⁻⁴ · I + 15 µA\n50 Hz do 60 Hz 0,105 A do 1,05 A CMC 9 · 10⁻⁴ · I + 0,18 mA\n50 Hz do 60 Hz 1,05 A do 30 A CMC 2 · 10⁻⁴ · I + 1 mA\n50 Hz do 60 Hz 30 A do 300 A CMC 2,5 · 10⁻⁴ · I + 1 mA\n50 Hz do 60 Hz 300 A do 1200 A CMC 2,5 · 10⁻⁴ · I + 0,05 A\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PW-04 w oparciu o EURAMET cg-15 v.3.0","search_en":"Calibrators Data acquisition cards Clamp meters Analogue ammeters Digital ammeters Multimeters Measuring probes Power supplies Calibration — AC current Internal procedure; At permanent location (S) and outside of it (P) AC current Internal procedure At permanent location (S) and outside of it (P) 50 Hz to 60 Hz 50 Hz to 60 Hz 50 Hz to 60 Hz 50 Hz to 60 Hz 50 Hz to 60 Hz 50 Hz to 60 Hz 50 Hz to 60 Hz 50 Hz to 60 Hz PW-04 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-04 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"50 Hz bis 60 Hz","range":"10 µA to 100,5 µA","cmc":"8 · 10⁻⁴ · I + 15 nA"},{"name":"50 Hz bis 60 Hz","range":"0,1005 mA to 1,05 mA","cmc":"8 · 10⁻⁴ · I + 0,15 µA"},{"name":"50 Hz bis 60 Hz","range":"1,05 mA to 10,5 mA","cmc":"6,2 · 10⁻⁴ · I + 1,5 µA"},{"name":"50 Hz bis 60 Hz","range":"10,5 A to 105 mA","cmc":"6,2 · 10⁻⁴ · I + 15 µA"},{"name":"50 Hz bis 60 Hz","range":"0,105 A to 1,05 A","cmc":"9 · 10⁻⁴ · I + 0,18 mA"},{"name":"50 Hz bis 60 Hz","range":"1,05 A to 30 A","cmc":"2 · 10⁻⁴ · I + 1 mA"},{"name":"50 Hz bis 60 Hz","range":"30 A to 300 A","cmc":"2,5 · 10⁻⁴ · I + 1 mA"},{"name":"50 Hz bis 60 Hz","range":"300 A to 1200 A","cmc":"2,5 · 10⁻⁴ · I + 0,05 A"}],"reference_de":"PW-04 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Messkarten Zangenmessgeräte Analoge Strommessgeräte Digitale Strommessgeräte Multimeter Messsonden Netzgeräte Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) AC-Strom Internes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz bis 60 Hz 50 Hz bis 60 Hz 50 Hz bis 60 Hz 50 Hz bis 60 Hz 50 Hz bis 60 Hz 50 Hz bis 60 Hz 50 Hz bis 60 Hz 50 Hz bis 60 Hz PW-04 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nMesskarten\nZangenmessgeräte\nAnaloge Strommessgeräte\nDigitale Strommessgeräte\nMultimeter\nMesssonden\nNetzgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"50 Hz 至 60 Hz","range":"10 µA to 100,5 µA","cmc":"8 · 10⁻⁴ · I + 15 nA"},{"name":"50 Hz 至 60 Hz","range":"0,1005 mA to 1,05 mA","cmc":"8 · 10⁻⁴ · I + 0,15 µA"},{"name":"50 Hz 至 60 Hz","range":"1,05 mA to 10,5 mA","cmc":"6,2 · 10⁻⁴ · I + 1,5 µA"},{"name":"50 Hz 至 60 Hz","range":"10,5 A to 105 mA","cmc":"6,2 · 10⁻⁴ · I + 15 µA"},{"name":"50 Hz 至 60 Hz","range":"0,105 A to 1,05 A","cmc":"9 · 10⁻⁴ · I + 0,18 mA"},{"name":"50 Hz 至 60 Hz","range":"1,05 A to 30 A","cmc":"2 · 10⁻⁴ · I + 1 mA"},{"name":"50 Hz 至 60 Hz","range":"30 A to 300 A","cmc":"2,5 · 10⁻⁴ · I + 1 mA"},{"name":"50 Hz 至 60 Hz","range":"300 A to 1200 A","cmc":"2,5 · 10⁻⁴ · I + 0,05 A"}],"reference_zh":"PW-04 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"交流电流","search_zh":"校准器 测量卡 钳形表 模拟电流表 数字电流表 万用表 测量探头 电源 校准 — 交流电流 内部程序；在固定地点 (S) 及固定地点以外 (P) 交流电流 内部程序 在固定地点 (S) 及固定地点以外 (P) 50 Hz 至 60 Hz 50 Hz 至 60 Hz 50 Hz 至 60 Hz 50 Hz 至 60 Hz 50 Hz 至 60 Hz 50 Hz 至 60 Hz 50 Hz 至 60 Hz 50 Hz 至 60 Hz PW-04 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n测量卡\n钳形表\n模拟电流表\n数字电流表\n万用表\n测量探头\n电源","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"50 Hz až 60 Hz","range":"10 µA to 100,5 µA","cmc":"8 · 10⁻⁴ · I + 15 nA"},{"name":"50 Hz až 60 Hz","range":"0,1005 mA to 1,05 mA","cmc":"8 · 10⁻⁴ · I + 0,15 µA"},{"name":"50 Hz až 60 Hz","range":"1,05 mA to 10,5 mA","cmc":"6,2 · 10⁻⁴ · I + 1,5 µA"},{"name":"50 Hz až 60 Hz","range":"10,5 A to 105 mA","cmc":"6,2 · 10⁻⁴ · I + 15 µA"},{"name":"50 Hz až 60 Hz","range":"0,105 A to 1,05 A","cmc":"9 · 10⁻⁴ · I + 0,18 mA"},{"name":"50 Hz až 60 Hz","range":"1,05 A to 30 A","cmc":"2 · 10⁻⁴ · I + 1 mA"},{"name":"50 Hz až 60 Hz","range":"30 A to 300 A","cmc":"2,5 · 10⁻⁴ · I + 1 mA"},{"name":"50 Hz až 60 Hz","range":"300 A to 1200 A","cmc":"2,5 · 10⁻⁴ · I + 0,05 A"}],"reference_cs":"PW-04 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Měřicí karty Klešťové měřiče Analogové měřiče proudu Digitální měřiče proudu Multimetry Měřicí sondy Napájecí zdroje Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Proud AC Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) 50 Hz až 60 Hz 50 Hz až 60 Hz 50 Hz až 60 Hz 50 Hz až 60 Hz 50 Hz až 60 Hz 50 Hz až 60 Hz 50 Hz až 60 Hz 50 Hz až 60 Hz PW-04 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nMěřicí karty\nKlešťové měřiče\nAnalogové měřiče proudu\nDigitální měřiče proudu\nMultimetry\nMěřicí sondy\nNapájecí zdroje"},{"_id":"89e0b760b1a8ae25c66fc008","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Kalibratory\nKarty pomiarowe\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry\nZasilacze","test_object_en":"Calibrators\nData acquisition cards\nAnalogue ammeters\nDigital ammeters\nMultimeters\nPower supplies","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"1 kHz","range":"10 µA do 100,5 µA","cmc":"6,2·10⁻⁴ · I + 14 nA"},{"name":"1 kHz","range":"0,1005 mA do 1,05 mA","cmc":"6,2·10⁻⁴ · I + 0,15 µA"},{"name":"1 kHz","range":"1,05 mA do 10,5 mA","cmc":"6,2·10⁻⁴ · I + 1,5 µA"},{"name":"1 kHz","range":"10,5 mA do 105 mA","cmc":"6,2·10⁻⁴ · I + 15 µA"},{"name":"1 kHz","range":"0,105 A do 1,05 A","cmc":"9·10⁻⁴ · I + 0,18 mA"},{"name":"1 kHz","range":"1,05 A do 10,5 A","cmc":"1,5·10⁻³ · I + 3,5 mA"},{"name":"1 kHz","range":"10,5 A do 30,5 A","cmc":"1,5·10⁻³ · I + 10 mA"}],"parameters_en":[{"name":"1 kHz","range":"10 µA to 100,5 µA","cmc":"6,2·10⁻⁴ · I + 14 nA"},{"name":"1 kHz","range":"0,1005 mA to 1,05 mA","cmc":"6,2·10⁻⁴ · I + 0,15 µA"},{"name":"1 kHz","range":"1,05 mA to 10,5 mA","cmc":"6,2·10⁻⁴ · I + 1,5 µA"},{"name":"1 kHz","range":"10,5 mA to 105 mA","cmc":"6,2·10⁻⁴ · I + 15 µA"},{"name":"1 kHz","range":"0,105 A to 1,05 A","cmc":"9·10⁻⁴ · I + 0,18 mA"},{"name":"1 kHz","range":"1,05 A to 10,5 A","cmc":"1,5·10⁻³ · I + 3,5 mA"},{"name":"1 kHz","range":"10,5 A to 30,5 A","cmc":"1,5·10⁻³ · I + 10 mA"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n1 kHz 10 µA do 100,5 µA CMC 6,2·10⁻⁴ · I + 14 nA\n1 kHz 0,1005 mA do 1,05 mA CMC 6,2·10⁻⁴ · I + 0,15 µA\n1 kHz 1,05 mA do 10,5 mA CMC 6,2·10⁻⁴ · I + 1,5 µA\n1 kHz 10,5 mA do 105 mA CMC 6,2·10⁻⁴ · I + 15 µA\n1 kHz 0,105 A do 1,05 A CMC 9·10⁻⁴ · I + 0,18 mA\n1 kHz 1,05 A do 10,5 A CMC 1,5·10⁻³ · I + 3,5 mA\n1 kHz 10,5 A do 30,5 A CMC 1,5·10⁻³ · I + 10 mA\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-04 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-04","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":true,"location_of_activity":"S, P","note":"I – wielkość mierzona (A)","note_en":"I – measured quantity (A)","search_text":"Kalibratory\nKarty pomiarowe\nMierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry\nZasilacze Wzorcowanie — Prąd AC\nZakres:\n1 kHz 10 µA do 100,5 µA CMC 6,2·10⁻⁴ · I + 14 nA\n1 kHz 0,1005 mA do 1,05 mA CMC 6,2·10⁻⁴ · I + 0,15 µA\n1 kHz 1,05 mA do 10,5 mA CMC 6,2·10⁻⁴ · I + 1,5 µA\n1 kHz 10,5 mA do 105 mA CMC 6,2·10⁻⁴ · I + 15 µA\n1 kHz 0,105 A do 1,05 A CMC 9·10⁻⁴ · I + 0,18 mA\n1 kHz 1,05 A do 10,5 A CMC 1,5·10⁻³ · I + 3,5 mA\n1 kHz 10,5 A do 30,5 A CMC 1,5·10⁻³ · I + 10 mA\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PW-04 w oparciu o EURAMET cg-15 v.3.0 Kalibratory\nKarty pomiarowe\nMierniki pradu analogowe\nMierniki pradu cyfrowe\nMultimetry\nZasilacze Wzorcowanie — Prad AC\nZakres:\n1 kHz 10 µA do 100,5 µA CMC 6,2·10⁻⁴ · I + 14 nA\n1 kHz 0,1005 mA do 1,05 mA CMC 6,2·10⁻⁴ · I + 0,15 µA\n1 kHz 1,05 mA do 10,5 mA CMC 6,2·10⁻⁴ · I + 1,5 µA\n1 kHz 10,5 mA do 105 mA CMC 6,2·10⁻⁴ · I + 15 µA\n1 kHz 0,105 A do 1,05 A CMC 9·10⁻⁴ · I + 0,18 mA\n1 kHz 1,05 A do 10,5 A CMC 1,5·10⁻³ · I + 3,5 mA\n1 kHz 10,5 A do 30,5 A CMC 1,5·10⁻³ · I + 10 mA\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PW-04 w oparciu o EURAMET cg-15 v.3.0","search_en":"Calibrators Data acquisition cards Analogue ammeters Digital ammeters Multimeters Power supplies Calibration — AC current Internal procedure; At permanent location (S) and outside of it (P) AC current Internal procedure At permanent location (S) and outside of it (P) 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz PW-04 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-04 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"1 kHz","range":"10 µA to 100,5 µA","cmc":"6,2·10⁻⁴ · I + 14 nA"},{"name":"1 kHz","range":"0,1005 mA to 1,05 mA","cmc":"6,2·10⁻⁴ · I + 0,15 µA"},{"name":"1 kHz","range":"1,05 mA to 10,5 mA","cmc":"6,2·10⁻⁴ · I + 1,5 µA"},{"name":"1 kHz","range":"10,5 mA to 105 mA","cmc":"6,2·10⁻⁴ · I + 15 µA"},{"name":"1 kHz","range":"0,105 A to 1,05 A","cmc":"9·10⁻⁴ · I + 0,18 mA"},{"name":"1 kHz","range":"1,05 A to 10,5 A","cmc":"1,5·10⁻³ · I + 3,5 mA"},{"name":"1 kHz","range":"10,5 A to 30,5 A","cmc":"1,5·10⁻³ · I + 10 mA"}],"reference_de":"PW-04 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Messkarten Analoge Strommessgeräte Digitale Strommessgeräte Multimeter Netzgeräte Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) AC-Strom Internes Verfahren Am festen Standort (S) und außerhalb (P) 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz PW-04 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Kalibratoren\nMesskarten\nAnaloge Strommessgeräte\nDigitale Strommessgeräte\nMultimeter\nNetzgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"1 kHz","range":"10 µA to 100,5 µA","cmc":"6,2·10⁻⁴ · I + 14 nA"},{"name":"1 kHz","range":"0,1005 mA to 1,05 mA","cmc":"6,2·10⁻⁴ · I + 0,15 µA"},{"name":"1 kHz","range":"1,05 mA to 10,5 mA","cmc":"6,2·10⁻⁴ · I + 1,5 µA"},{"name":"1 kHz","range":"10,5 mA to 105 mA","cmc":"6,2·10⁻⁴ · I + 15 µA"},{"name":"1 kHz","range":"0,105 A to 1,05 A","cmc":"9·10⁻⁴ · I + 0,18 mA"},{"name":"1 kHz","range":"1,05 A to 10,5 A","cmc":"1,5·10⁻³ · I + 3,5 mA"},{"name":"1 kHz","range":"10,5 A to 30,5 A","cmc":"1,5·10⁻³ · I + 10 mA"}],"reference_zh":"PW-04 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"交流电流","search_zh":"校准器 测量卡 模拟电流表 数字电流表 万用表 电源 校准 — 交流电流 内部程序；在固定地点 (S) 及固定地点以外 (P) 交流电流 内部程序 在固定地点 (S) 及固定地点以外 (P) 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz PW-04 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"校准器\n测量卡\n模拟电流表\n数字电流表\n万用表\n电源","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"1 kHz","range":"10 µA to 100,5 µA","cmc":"6,2·10⁻⁴ · I + 14 nA"},{"name":"1 kHz","range":"0,1005 mA to 1,05 mA","cmc":"6,2·10⁻⁴ · I + 0,15 µA"},{"name":"1 kHz","range":"1,05 mA to 10,5 mA","cmc":"6,2·10⁻⁴ · I + 1,5 µA"},{"name":"1 kHz","range":"10,5 mA to 105 mA","cmc":"6,2·10⁻⁴ · I + 15 µA"},{"name":"1 kHz","range":"0,105 A to 1,05 A","cmc":"9·10⁻⁴ · I + 0,18 mA"},{"name":"1 kHz","range":"1,05 A to 10,5 A","cmc":"1,5·10⁻³ · I + 3,5 mA"},{"name":"1 kHz","range":"10,5 A to 30,5 A","cmc":"1,5·10⁻³ · I + 10 mA"}],"reference_cs":"PW-04 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Měřicí karty Analogové měřiče proudu Digitální měřiče proudu Multimetry Napájecí zdroje Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Proud AC Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz PW-04 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory\nMěřicí karty\nAnalogové měřiče proudu\nDigitální měřiče proudu\nMultimetry\nNapájecí zdroje"},{"_id":"a53350b88855f08c09f988bd","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Kalibratory rezystancji\nKarty pomiarowe\nMierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMierniki parametrów sieci\nMierniki rezystancji izolacji\nMultimetry","test_object_en":"Resistance calibrators\nData acquisition cards\nAnalogue ohmmeters\nDigital ohmmeters\nPower network parameter meters\nInsulation resistance meters\nMultimeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,001 Ω do 1,2 Ω","cmc":"2,8·10⁻⁵ · R + 7 µΩ"},{"name":"","range":"1,2 Ω do 12 Ω","cmc":"1,9·10⁻⁵ · R + 34 µΩ"},{"name":"","range":"12 Ω do 120 Ω","cmc":"1,7·10⁻⁵ · R + 0,1 mΩ"},{"name":"","range":"0,12 kΩ do 1,2 kΩ","cmc":"1,5·10⁻⁵ · R + 0,9 mΩ"},{"name":"","range":"1,2 kΩ do 12 kΩ","cmc":"1,8·10⁻⁵ · R + 9 mΩ"},{"name":"","range":"12 kΩ do 120 kΩ","cmc":"1,8·10⁻⁵ · R + 1 Ω"},{"name":"","range":"0,12 MΩ do 1,2 MΩ","cmc":"2,2·10⁻⁵ · R + 2,3 Ω"},{"name":"","range":"1,2 MΩ do 12 MΩ","cmc":"2,8·10⁻⁵ · R + 0,1 kΩ"},{"name":"","range":"12 MΩ do 90 MΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"90 MΩ do 900 MΩ","cmc":"6·10⁻⁴ · R"},{"name":"","range":"0,9 GΩ do 9 GΩ","cmc":"2,5·10⁻³ · R"},{"name":"","range":"9 GΩ do 1000 GΩ","cmc":"2,7·10⁻² · R"},{"name":"Punkty stałe:","range":"0,0001 Ω","cmc":"2·10⁻³ · R"},{"name":"Punkty stałe:","range":"0,001 Ω","cmc":"2·10⁻⁴ · R"},{"name":"Punkty stałe:","range":"0,01 Ω; 0,1 Ω","cmc":"1·10⁻⁴ · R"},{"name":"Punkty stałe:","range":"1Ω; 10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ","cmc":"3·10⁻⁵ · R"},{"name":"Punkty stałe:","range":"1 MΩ","cmc":"6·10⁻⁵ · R"},{"name":"Punkty stałe:","range":"1 GΩ","cmc":"2·10⁻³ · R"},{"name":"Punkty stałe:","range":"10 GΩ","cmc":"5·10⁻³ · R"},{"name":"Punkty stałe:","range":"50 GΩ; 100 GΩ; 200 GΩ","cmc":"1·10⁻² · R"},{"name":"Punkty stałe:","range":"250 GΩ; 500 GΩ; 1 TΩ","cmc":"2,5·10⁻² · R"}],"parameters_en":[{"name":"","range":"0,001 Ω to 1,2 Ω","cmc":"2,8·10⁻⁵ · R + 7 µΩ"},{"name":"","range":"1,2 Ω to 12 Ω","cmc":"1,9·10⁻⁵ · R + 34 µΩ"},{"name":"","range":"12 Ω to 120 Ω","cmc":"1,7·10⁻⁵ · R + 0,1 mΩ"},{"name":"","range":"0,12 kΩ to 1,2 kΩ","cmc":"1,5·10⁻⁵ · R + 0,9 mΩ"},{"name":"","range":"1,2 kΩ to 12 kΩ","cmc":"1,8·10⁻⁵ · R + 9 mΩ"},{"name":"","range":"12 kΩ to 120 kΩ","cmc":"1,8·10⁻⁵ · R + 1 Ω"},{"name":"","range":"0,12 MΩ to 1,2 MΩ","cmc":"2,2·10⁻⁵ · R + 2,3 Ω"},{"name":"","range":"1,2 MΩ to 12 MΩ","cmc":"2,8·10⁻⁵ · R + 0,1 kΩ"},{"name":"","range":"12 MΩ to 90 MΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"90 MΩ to 900 MΩ","cmc":"6·10⁻⁴ · R"},{"name":"","range":"0,9 GΩ to 9 GΩ","cmc":"2,5·10⁻³ · R"},{"name":"","range":"9 GΩ to 1000 GΩ","cmc":"2,7·10⁻² · R"},{"name":"Fixed points:","range":"0,0001 Ω","cmc":"2·10⁻³ · R"},{"name":"Fixed points:","range":"0,001 Ω","cmc":"2·10⁻⁴ · R"},{"name":"Fixed points:","range":"0,01 Ω; 0,1 Ω","cmc":"1·10⁻⁴ · R"},{"name":"Fixed points:","range":"1Ω; 10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ","cmc":"3·10⁻⁵ · R"},{"name":"Fixed points:","range":"1 MΩ","cmc":"6·10⁻⁵ · R"},{"name":"Fixed points:","range":"1 GΩ","cmc":"2·10⁻³ · R"},{"name":"Fixed points:","range":"10 GΩ","cmc":"5·10⁻³ · R"},{"name":"Fixed points:","range":"50 GΩ; 100 GΩ; 200 GΩ","cmc":"1·10⁻² · R"},{"name":"Fixed points:","range":"250 GΩ; 500 GΩ; 1 TΩ","cmc":"2,5·10⁻² · R"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 1,2 Ω CMC 2,8·10⁻⁵ · R + 7 µΩ\n1,2 Ω do 12 Ω CMC 1,9·10⁻⁵ · R + 34 µΩ\n12 Ω do 120 Ω CMC 1,7·10⁻⁵ · R + 0,1 mΩ\n0,12 kΩ do 1,2 kΩ CMC 1,5·10⁻⁵ · R + 0,9 mΩ\n1,2 kΩ do 12 kΩ CMC 1,8·10⁻⁵ · R + 9 mΩ\n12 kΩ do 120 kΩ CMC 1,8·10⁻⁵ · R + 1 Ω\n0,12 MΩ do 1,2 MΩ CMC 2,2·10⁻⁵ · R + 2,3 Ω\n1,2 MΩ do 12 MΩ CMC 2,8·10⁻⁵ · R + 0,1 kΩ\n12 MΩ do 90 MΩ CMC 2·10⁻⁴ · R\n90 MΩ do 900 MΩ CMC 6·10⁻⁴ · R\n0,9 GΩ do 9 GΩ CMC 2,5·10⁻³ · R\n9 GΩ do 1000 GΩ CMC 2,7·10⁻² · R\nPunkty stałe: 0,0001 Ω CMC 2·10⁻³ · R\nPunkty stałe: 0,001 Ω CMC 2·10⁻⁴ · R\nPunkty stałe: 0,01 Ω; 0,1 Ω CMC 1·10⁻⁴ · R\nPunkty stałe: 1Ω; 10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ CMC 3·10⁻⁵ · R\nPunkty stałe: 1 MΩ CMC 6·10⁻⁵ · R\nPunkty stałe: 1 GΩ CMC 2·10⁻³ · R\nPunkty stałe: 10 GΩ CMC 5·10⁻³ · R\nPunkty stałe: 50 GΩ; 100 GΩ; 200 GΩ CMC 1·10⁻² · R\nPunkty stałe: 250 GΩ; 500 GΩ; 1 TΩ CMC 2,5·10⁻² · R\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-04 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PW-04","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"S, P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured quantity (Ω)","search_text":"Kalibratory rezystancji\nKarty pomiarowe\nMierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMierniki parametrów sieci\nMierniki rezystancji izolacji\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 1,2 Ω CMC 2,8·10⁻⁵ · R + 7 µΩ\n1,2 Ω do 12 Ω CMC 1,9·10⁻⁵ · R + 34 µΩ\n12 Ω do 120 Ω CMC 1,7·10⁻⁵ · R + 0,1 mΩ\n0,12 kΩ do 1,2 kΩ CMC 1,5·10⁻⁵ · R + 0,9 mΩ\n1,2 kΩ do 12 kΩ CMC 1,8·10⁻⁵ · R + 9 mΩ\n12 kΩ do 120 kΩ CMC 1,8·10⁻⁵ · R + 1 Ω\n0,12 MΩ do 1,2 MΩ CMC 2,2·10⁻⁵ · R + 2,3 Ω\n1,2 MΩ do 12 MΩ CMC 2,8·10⁻⁵ · R + 0,1 kΩ\n12 MΩ do 90 MΩ CMC 2·10⁻⁴ · R\n90 MΩ do 900 MΩ CMC 6·10⁻⁴ · R\n0,9 GΩ do 9 GΩ CMC 2,5·10⁻³ · R\n9 GΩ do 1000 GΩ CMC 2,7·10⁻² · R\nPunkty stałe: 0,0001 Ω CMC 2·10⁻³ · R\nPunkty stałe: 0,001 Ω CMC 2·10⁻⁴ · R\nPunkty stałe: 0,01 Ω; 0,1 Ω CMC 1·10⁻⁴ · R\nPunkty stałe: 1Ω; 10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ CMC 3·10⁻⁵ · R\nPunkty stałe: 1 MΩ CMC 6·10⁻⁵ · R\nPunkty stałe: 1 GΩ CMC 2·10⁻³ · R\nPunkty stałe: 10 GΩ CMC 5·10⁻³ · R\nPunkty stałe: 50 GΩ; 100 GΩ; 200 GΩ CMC 1·10⁻² · R\nPunkty stałe: 250 GΩ; 500 GΩ; 1 TΩ CMC 2,5·10⁻² · R\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PW-04 w oparciu o EURAMET cg-15 v.3.0 Kalibratory rezystancji\nKarty pomiarowe\nMierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMierniki parametrow sieci\nMierniki rezystancji izolacji\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n0,001 Ω do 1,2 Ω CMC 2,8·10⁻⁵ · R + 7 µΩ\n1,2 Ω do 12 Ω CMC 1,9·10⁻⁵ · R + 34 µΩ\n12 Ω do 120 Ω CMC 1,7·10⁻⁵ · R + 0,1 mΩ\n0,12 kΩ do 1,2 kΩ CMC 1,5·10⁻⁵ · R + 0,9 mΩ\n1,2 kΩ do 12 kΩ CMC 1,8·10⁻⁵ · R + 9 mΩ\n12 kΩ do 120 kΩ CMC 1,8·10⁻⁵ · R + 1 Ω\n0,12 MΩ do 1,2 MΩ CMC 2,2·10⁻⁵ · R + 2,3 Ω\n1,2 MΩ do 12 MΩ CMC 2,8·10⁻⁵ · R + 0,1 kΩ\n12 MΩ do 90 MΩ CMC 2·10⁻⁴ · R\n90 MΩ do 900 MΩ CMC 6·10⁻⁴ · R\n0,9 GΩ do 9 GΩ CMC 2,5·10⁻³ · R\n9 GΩ do 1000 GΩ CMC 2,7·10⁻² · R\nPunkty stale: 0,0001 Ω CMC 2·10⁻³ · R\nPunkty stale: 0,001 Ω CMC 2·10⁻⁴ · R\nPunkty stale: 0,01 Ω; 0,1 Ω CMC 1·10⁻⁴ · R\nPunkty stale: 1Ω; 10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ CMC 3·10⁻⁵ · R\nPunkty stale: 1 MΩ CMC 6·10⁻⁵ · R\nPunkty stale: 1 GΩ CMC 2·10⁻³ · R\nPunkty stale: 10 GΩ CMC 5·10⁻³ · R\nPunkty stale: 50 GΩ; 100 GΩ; 200 GΩ CMC 1·10⁻² · R\nPunkty stale: 250 GΩ; 500 GΩ; 1 TΩ CMC 2,5·10⁻² · R\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PW-04 w oparciu o EURAMET cg-15 v.3.0","search_en":"Resistance calibrators Data acquisition cards Analogue ohmmeters Digital ohmmeters Power network parameter meters Insulation resistance meters Multimeters Calibration — DC resistance Internal procedure; At permanent location (S) and outside of it (P) DC resistance Internal procedure At permanent location (S) and outside of it (P) Fixed points: Fixed points: Fixed points: Fixed points: Fixed points: Fixed points: Fixed points: Fixed points: Fixed points: PW-04 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PW-04 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,001 Ω to 1,2 Ω","cmc":"2,8·10⁻⁵ · R + 7 µΩ"},{"name":"","range":"1,2 Ω to 12 Ω","cmc":"1,9·10⁻⁵ · R + 34 µΩ"},{"name":"","range":"12 Ω to 120 Ω","cmc":"1,7·10⁻⁵ · R + 0,1 mΩ"},{"name":"","range":"0,12 kΩ to 1,2 kΩ","cmc":"1,5·10⁻⁵ · R + 0,9 mΩ"},{"name":"","range":"1,2 kΩ to 12 kΩ","cmc":"1,8·10⁻⁵ · R + 9 mΩ"},{"name":"","range":"12 kΩ to 120 kΩ","cmc":"1,8·10⁻⁵ · R + 1 Ω"},{"name":"","range":"0,12 MΩ to 1,2 MΩ","cmc":"2,2·10⁻⁵ · R + 2,3 Ω"},{"name":"","range":"1,2 MΩ to 12 MΩ","cmc":"2,8·10⁻⁵ · R + 0,1 kΩ"},{"name":"","range":"12 MΩ to 90 MΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"90 MΩ to 900 MΩ","cmc":"6·10⁻⁴ · R"},{"name":"","range":"0,9 GΩ to 9 GΩ","cmc":"2,5·10⁻³ · R"},{"name":"","range":"9 GΩ to 1000 GΩ","cmc":"2,7·10⁻² · R"},{"name":"Feste Punkte:","range":"0,0001 Ω","cmc":"2·10⁻³ · R"},{"name":"Feste Punkte:","range":"0,001 Ω","cmc":"2·10⁻⁴ · R"},{"name":"Feste Punkte:","range":"0,01 Ω; 0,1 Ω","cmc":"1·10⁻⁴ · R"},{"name":"Feste Punkte:","range":"1Ω; 10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ","cmc":"3·10⁻⁵ · R"},{"name":"Feste Punkte:","range":"1 MΩ","cmc":"6·10⁻⁵ · R"},{"name":"Feste Punkte:","range":"1 GΩ","cmc":"2·10⁻³ · R"},{"name":"Feste Punkte:","range":"10 GΩ","cmc":"5·10⁻³ · R"},{"name":"Feste Punkte:","range":"50 GΩ; 100 GΩ; 200 GΩ","cmc":"1·10⁻² · R"},{"name":"Feste Punkte:","range":"250 GΩ; 500 GΩ; 1 TΩ","cmc":"2,5·10⁻² · R"}],"reference_de":"PW-04 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"DC-Widerstand","search_de":"Widerstandskalibratoren Messkarten Analoge Widerstandsmessgeräte Digitale Widerstandsmessgeräte Netzparametermessgeräte Isolationswiderstandsmessgeräte Multimeter Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) DC-Widerstand Internes Verfahren Am festen Standort (S) und außerhalb (P) Feste Punkte: Feste Punkte: Feste Punkte: Feste Punkte: Feste Punkte: Feste Punkte: Feste Punkte: Feste Punkte: Feste Punkte: PW-04 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Widerstandskalibratoren\nMesskarten\nAnaloge Widerstandsmessgeräte\nDigitale Widerstandsmessgeräte\nNetzparametermessgeräte\nIsolationswiderstandsmessgeräte\nMultimeter","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,001 Ω to 1,2 Ω","cmc":"2,8·10⁻⁵ · R + 7 µΩ"},{"name":"","range":"1,2 Ω to 12 Ω","cmc":"1,9·10⁻⁵ · R + 34 µΩ"},{"name":"","range":"12 Ω to 120 Ω","cmc":"1,7·10⁻⁵ · R + 0,1 mΩ"},{"name":"","range":"0,12 kΩ to 1,2 kΩ","cmc":"1,5·10⁻⁵ · R + 0,9 mΩ"},{"name":"","range":"1,2 kΩ to 12 kΩ","cmc":"1,8·10⁻⁵ · R + 9 mΩ"},{"name":"","range":"12 kΩ to 120 kΩ","cmc":"1,8·10⁻⁵ · R + 1 Ω"},{"name":"","range":"0,12 MΩ to 1,2 MΩ","cmc":"2,2·10⁻⁵ · R + 2,3 Ω"},{"name":"","range":"1,2 MΩ to 12 MΩ","cmc":"2,8·10⁻⁵ · R + 0,1 kΩ"},{"name":"","range":"12 MΩ to 90 MΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"90 MΩ to 900 MΩ","cmc":"6·10⁻⁴ · R"},{"name":"","range":"0,9 GΩ to 9 GΩ","cmc":"2,5·10⁻³ · R"},{"name":"","range":"9 GΩ to 1000 GΩ","cmc":"2,7·10⁻² · R"},{"name":"固定点：","range":"0,0001 Ω","cmc":"2·10⁻³ · R"},{"name":"固定点：","range":"0,001 Ω","cmc":"2·10⁻⁴ · R"},{"name":"固定点：","range":"0,01 Ω; 0,1 Ω","cmc":"1·10⁻⁴ · R"},{"name":"固定点：","range":"1Ω; 10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ","cmc":"3·10⁻⁵ · R"},{"name":"固定点：","range":"1 MΩ","cmc":"6·10⁻⁵ · R"},{"name":"固定点：","range":"1 GΩ","cmc":"2·10⁻³ · R"},{"name":"固定点：","range":"10 GΩ","cmc":"5·10⁻³ · R"},{"name":"固定点：","range":"50 GΩ; 100 GΩ; 200 GΩ","cmc":"1·10⁻² · R"},{"name":"固定点：","range":"250 GΩ; 500 GΩ; 1 TΩ","cmc":"2,5·10⁻² · R"}],"reference_zh":"PW-04 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"直流电阻","search_zh":"电阻校准器 测量卡 模拟式电阻表 数字电阻测量仪 电网参数测量仪 绝缘电阻测量仪 万用表 校准 — 直流电阻 内部程序；在固定地点 (S) 及固定地点以外 (P) 直流电阻 内部程序 在固定地点 (S) 及固定地点以外 (P) 固定点： 固定点： 固定点： 固定点： 固定点： 固定点： 固定点： 固定点： 固定点： PW-04 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电阻校准器\n测量卡\n模拟式电阻表\n数字电阻测量仪\n电网参数测量仪\n绝缘电阻测量仪\n万用表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,001 Ω to 1,2 Ω","cmc":"2,8·10⁻⁵ · R + 7 µΩ"},{"name":"","range":"1,2 Ω to 12 Ω","cmc":"1,9·10⁻⁵ · R + 34 µΩ"},{"name":"","range":"12 Ω to 120 Ω","cmc":"1,7·10⁻⁵ · R + 0,1 mΩ"},{"name":"","range":"0,12 kΩ to 1,2 kΩ","cmc":"1,5·10⁻⁵ · R + 0,9 mΩ"},{"name":"","range":"1,2 kΩ to 12 kΩ","cmc":"1,8·10⁻⁵ · R + 9 mΩ"},{"name":"","range":"12 kΩ to 120 kΩ","cmc":"1,8·10⁻⁵ · R + 1 Ω"},{"name":"","range":"0,12 MΩ to 1,2 MΩ","cmc":"2,2·10⁻⁵ · R + 2,3 Ω"},{"name":"","range":"1,2 MΩ to 12 MΩ","cmc":"2,8·10⁻⁵ · R + 0,1 kΩ"},{"name":"","range":"12 MΩ to 90 MΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"90 MΩ to 900 MΩ","cmc":"6·10⁻⁴ · R"},{"name":"","range":"0,9 GΩ to 9 GΩ","cmc":"2,5·10⁻³ · R"},{"name":"","range":"9 GΩ to 1000 GΩ","cmc":"2,7·10⁻² · R"},{"name":"Pevné body:","range":"0,0001 Ω","cmc":"2·10⁻³ · R"},{"name":"Pevné body:","range":"0,001 Ω","cmc":"2·10⁻⁴ · R"},{"name":"Pevné body:","range":"0,01 Ω; 0,1 Ω","cmc":"1·10⁻⁴ · R"},{"name":"Pevné body:","range":"1Ω; 10Ω; 100Ω; 1kΩ; 10kΩ; 100kΩ","cmc":"3·10⁻⁵ · R"},{"name":"Pevné body:","range":"1 MΩ","cmc":"6·10⁻⁵ · R"},{"name":"Pevné body:","range":"1 GΩ","cmc":"2·10⁻³ · R"},{"name":"Pevné body:","range":"10 GΩ","cmc":"5·10⁻³ · R"},{"name":"Pevné body:","range":"50 GΩ; 100 GΩ; 200 GΩ","cmc":"1·10⁻² · R"},{"name":"Pevné body:","range":"250 GΩ; 500 GΩ; 1 TΩ","cmc":"2,5·10⁻² · R"}],"reference_cs":"PW-04 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Odpor DC","search_cs":"Kalibrátory odporu Měřicí karty Analogové měřiče odporu Digitální měřiče odporu Měřiče parametrů sítě Měřiče izolačního odporu Multimetry Kalibrace — Odpor DC Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Odpor DC Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) Pevné body: Pevné body: Pevné body: Pevné body: Pevné body: Pevné body: Pevné body: Pevné body: Pevné body: PW-04 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory odporu\nMěřicí karty\nAnalogové měřiče odporu\nDigitální měřiče odporu\nMěřiče parametrů sítě\nMěřiče izolačního odporu\nMultimetry"},{"_id":"42eb638e2453eea311dad013","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMierniki parametrów sieci\nMierniki rezystancji izolacji\nMultimetry","test_object_en":"Analogue ohmmeters\nDigital ohmmeters\nPower network parameter meters\nInsulation resistance meters\nMultimeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"100 Ω do 1000 kΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"1 MΩ do 15 MΩ","cmc":"5·10⁻⁴ · R"},{"name":"","range":"20 MΩ do 90 MΩ","cmc":"1·10⁻³ · R"},{"name":"","range":"0,1 GΩ do 2 GΩ","cmc":"2·10⁻³ · R"},{"name":"","range":"5 GΩ do 20 GΩ","cmc":"5·10⁻³ · R"},{"name":"","range":"50 GΩ do 200 GΩ","cmc":"1·10⁻² · R"},{"name":"","range":"0,25 TΩ do 1 TΩ","cmc":"2,5·10⁻² · R"}],"parameters_en":[{"name":"","range":"100 Ω to 1000 kΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"1 MΩ to 15 MΩ","cmc":"5·10⁻⁴ · R"},{"name":"","range":"20 MΩ to 90 MΩ","cmc":"1·10⁻³ · R"},{"name":"","range":"0,1 GΩ to 2 GΩ","cmc":"2·10⁻³ · R"},{"name":"","range":"5 GΩ to 20 GΩ","cmc":"5·10⁻³ · R"},{"name":"","range":"50 GΩ to 200 GΩ","cmc":"1·10⁻² · R"},{"name":"","range":"0,25 TΩ to 1 TΩ","cmc":"2,5·10⁻² · R"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n100 Ω do 1000 kΩ CMC 2·10⁻⁴ · R\n1 MΩ do 15 MΩ CMC 5·10⁻⁴ · R\n20 MΩ do 90 MΩ CMC 1·10⁻³ · R\n0,1 GΩ do 2 GΩ CMC 2·10⁻³ · R\n5 GΩ do 20 GΩ CMC 5·10⁻³ · R\n50 GΩ do 200 GΩ CMC 1·10⁻² · R\n0,25 TΩ do 1 TΩ CMC 2,5·10⁻² · R\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-02","norm_bases":["PW-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"S, P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured quantity (Ω)","search_text":"Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMierniki parametrów sieci\nMierniki rezystancji izolacji\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n100 Ω do 1000 kΩ CMC 2·10⁻⁴ · R\n1 MΩ do 15 MΩ CMC 5·10⁻⁴ · R\n20 MΩ do 90 MΩ CMC 1·10⁻³ · R\n0,1 GΩ do 2 GΩ CMC 2·10⁻³ · R\n5 GΩ do 20 GΩ CMC 5·10⁻³ · R\n50 GΩ do 200 GΩ CMC 1·10⁻² · R\n0,25 TΩ do 1 TΩ CMC 2,5·10⁻² · R\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) PW-02 Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMierniki parametrow sieci\nMierniki rezystancji izolacji\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n100 Ω do 1000 kΩ CMC 2·10⁻⁴ · R\n1 MΩ do 15 MΩ CMC 5·10⁻⁴ · R\n20 MΩ do 90 MΩ CMC 1·10⁻³ · R\n0,1 GΩ do 2 GΩ CMC 2·10⁻³ · R\n5 GΩ do 20 GΩ CMC 5·10⁻³ · R\n50 GΩ do 200 GΩ CMC 1·10⁻² · R\n0,25 TΩ do 1 TΩ CMC 2,5·10⁻² · R\nProcedura wewnetrzna; metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) PW-02","search_en":"Analogue ohmmeters Digital ohmmeters Power network parameter meters Insulation resistance meters Multimeters Calibration — DC resistance Internal procedure; direct method; At permanent location (S) and outside of it (P) DC resistance Internal procedure direct method At permanent location (S) and outside of it (P) PW-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"100 Ω to 1000 kΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"1 MΩ to 15 MΩ","cmc":"5·10⁻⁴ · R"},{"name":"","range":"20 MΩ to 90 MΩ","cmc":"1·10⁻³ · R"},{"name":"","range":"0,1 GΩ to 2 GΩ","cmc":"2·10⁻³ · R"},{"name":"","range":"5 GΩ to 20 GΩ","cmc":"5·10⁻³ · R"},{"name":"","range":"50 GΩ to 200 GΩ","cmc":"1·10⁻² · R"},{"name":"","range":"0,25 TΩ to 1 TΩ","cmc":"2,5·10⁻² · R"}],"regulatory_area_de":"DC-Widerstand","search_de":"Analoge Widerstandsmessgeräte Digitale Widerstandsmessgeräte Netzparametermessgeräte Isolationswiderstandsmessgeräte Multimeter Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Widerstand Internes Verfahren direktes Verfahren Am festen Standort (S) und außerhalb (P) PW-02","technique_de":"Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Analoge Widerstandsmessgeräte\nDigitale Widerstandsmessgeräte\nNetzparametermessgeräte\nIsolationswiderstandsmessgeräte\nMultimeter","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"100 Ω to 1000 kΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"1 MΩ to 15 MΩ","cmc":"5·10⁻⁴ · R"},{"name":"","range":"20 MΩ to 90 MΩ","cmc":"1·10⁻³ · R"},{"name":"","range":"0,1 GΩ to 2 GΩ","cmc":"2·10⁻³ · R"},{"name":"","range":"5 GΩ to 20 GΩ","cmc":"5·10⁻³ · R"},{"name":"","range":"50 GΩ to 200 GΩ","cmc":"1·10⁻² · R"},{"name":"","range":"0,25 TΩ to 1 TΩ","cmc":"2,5·10⁻² · R"}],"regulatory_area_zh":"直流电阻","search_zh":"模拟式电阻表 数字电阻测量仪 电网参数测量仪 绝缘电阻测量仪 万用表 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流电阻 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) PW-02","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"模拟式电阻表\n数字电阻测量仪\n电网参数测量仪\n绝缘电阻测量仪\n万用表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"100 Ω to 1000 kΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"1 MΩ to 15 MΩ","cmc":"5·10⁻⁴ · R"},{"name":"","range":"20 MΩ to 90 MΩ","cmc":"1·10⁻³ · R"},{"name":"","range":"0,1 GΩ to 2 GΩ","cmc":"2·10⁻³ · R"},{"name":"","range":"5 GΩ to 20 GΩ","cmc":"5·10⁻³ · R"},{"name":"","range":"50 GΩ to 200 GΩ","cmc":"1·10⁻² · R"},{"name":"","range":"0,25 TΩ to 1 TΩ","cmc":"2,5·10⁻² · R"}],"regulatory_area_cs":"Odpor DC","search_cs":"Analogové měřiče odporu Digitální měřiče odporu Měřiče parametrů sítě Měřiče izolačního odporu Multimetry Kalibrace — Odpor DC Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Odpor DC Vnitřní postup přímá metoda V trvalé lokalitě (S) i mimo ni (P) PW-02","technique_cs":"Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Analogové měřiče odporu\nDigitální měřiče odporu\nMěřiče parametrů sítě\nMěřiče izolačního odporu\nMultimetry"},{"_id":"1277c719c6bb397ca600faaa","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Kalibratory rezystancji\nKarty pomiarowe\nOscyloskopy\nSkopometry\nRezystory stałe\nRezystory regulowane\nWzorce rezystancji","test_object_en":"Resistance calibrators\nData acquisition cards\nOscilloscopes\nScopemeters\nFixed resistors\nVariable resistors\nResistance standards","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,001 kΩ do 1,2 Ω","cmc":"2,8·10⁻⁵ · R + 7 µΩ"},{"name":"","range":"1,2 Ω do 12 Ω","cmc":"1,9·10⁻⁵ · R + 34 µΩ"},{"name":"","range":"12 Ω do 120 Ω","cmc":"1,7·10⁻⁵ · R + 0,1 mΩ"},{"name":"","range":"0,12 kΩ do 1,2 kΩ","cmc":"1,5·10⁻⁵ · R + 0,9 mΩ"},{"name":"","range":"1,2 kΩ do 12 kΩ","cmc":"1,8·10⁻⁵ · R + 9 mΩ"},{"name":"","range":"12 kΩ do 120 kΩ","cmc":"1,8·10⁻⁵ · R + 1 Ω"},{"name":"","range":"0,12 MΩ do 1,2 MΩ","cmc":"2,2·10⁻⁵ · R + 2,3 Ω"},{"name":"","range":"1,2 MΩ do 12 MΩ","cmc":"2,8·10⁻⁵ · R + 0,1 kΩ"},{"name":"","range":"12 MΩ do 90 MΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"90 MΩ do 900 MΩ","cmc":"6·10⁻⁴ · R"},{"name":"","range":"0,9 GΩ do 9 GΩ","cmc":"2,5·10⁻⁴ · R"},{"name":"","range":"9 GΩ do 1000 GΩ","cmc":"2,7·10⁻² · R"}],"parameters_en":[{"name":"","range":"0,001 kΩ to 1,2 Ω","cmc":"2,8·10⁻⁵ · R + 7 µΩ"},{"name":"","range":"1,2 Ω to 12 Ω","cmc":"1,9·10⁻⁵ · R + 34 µΩ"},{"name":"","range":"12 Ω to 120 Ω","cmc":"1,7·10⁻⁵ · R + 0,1 mΩ"},{"name":"","range":"0,12 kΩ to 1,2 kΩ","cmc":"1,5·10⁻⁵ · R + 0,9 mΩ"},{"name":"","range":"1,2 kΩ to 12 kΩ","cmc":"1,8·10⁻⁵ · R + 9 mΩ"},{"name":"","range":"12 kΩ to 120 kΩ","cmc":"1,8·10⁻⁵ · R + 1 Ω"},{"name":"","range":"0,12 MΩ to 1,2 MΩ","cmc":"2,2·10⁻⁵ · R + 2,3 Ω"},{"name":"","range":"1,2 MΩ to 12 MΩ","cmc":"2,8·10⁻⁵ · R + 0,1 kΩ"},{"name":"","range":"12 MΩ to 90 MΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"90 MΩ to 900 MΩ","cmc":"6·10⁻⁴ · R"},{"name":"","range":"0,9 GΩ to 9 GΩ","cmc":"2,5·10⁻⁴ · R"},{"name":"","range":"9 GΩ to 1000 GΩ","cmc":"2,7·10⁻² · R"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,001 kΩ do 1,2 Ω CMC 2,8·10⁻⁵ · R + 7 µΩ\n1,2 Ω do 12 Ω CMC 1,9·10⁻⁵ · R + 34 µΩ\n12 Ω do 120 Ω CMC 1,7·10⁻⁵ · R + 0,1 mΩ\n0,12 kΩ do 1,2 kΩ CMC 1,5·10⁻⁵ · R + 0,9 mΩ\n1,2 kΩ do 12 kΩ CMC 1,8·10⁻⁵ · R + 9 mΩ\n12 kΩ do 120 kΩ CMC 1,8·10⁻⁵ · R + 1 Ω\n0,12 MΩ do 1,2 MΩ CMC 2,2·10⁻⁵ · R + 2,3 Ω\n1,2 MΩ do 12 MΩ CMC 2,8·10⁻⁵ · R + 0,1 kΩ\n12 MΩ do 90 MΩ CMC 2·10⁻⁴ · R\n90 MΩ do 900 MΩ CMC 6·10⁻⁴ · R\n0,9 GΩ do 9 GΩ CMC 2,5·10⁻⁴ · R\n9 GΩ do 1000 GΩ CMC 2,7·10⁻² · R\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-05","norm_bases":["PW-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":true,"location_of_activity":"S, P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured quantity (Ω)","search_text":"Kalibratory rezystancji\nKarty pomiarowe\nOscyloskopy\nSkopometry\nRezystory stałe\nRezystory regulowane\nWzorce rezystancji Wzorcowanie — Rezystancja DC\nZakres:\n0,001 kΩ do 1,2 Ω CMC 2,8·10⁻⁵ · R + 7 µΩ\n1,2 Ω do 12 Ω CMC 1,9·10⁻⁵ · R + 34 µΩ\n12 Ω do 120 Ω CMC 1,7·10⁻⁵ · R + 0,1 mΩ\n0,12 kΩ do 1,2 kΩ CMC 1,5·10⁻⁵ · R + 0,9 mΩ\n1,2 kΩ do 12 kΩ CMC 1,8·10⁻⁵ · R + 9 mΩ\n12 kΩ do 120 kΩ CMC 1,8·10⁻⁵ · R + 1 Ω\n0,12 MΩ do 1,2 MΩ CMC 2,2·10⁻⁵ · R + 2,3 Ω\n1,2 MΩ do 12 MΩ CMC 2,8·10⁻⁵ · R + 0,1 kΩ\n12 MΩ do 90 MΩ CMC 2·10⁻⁴ · R\n90 MΩ do 900 MΩ CMC 6·10⁻⁴ · R\n0,9 GΩ do 9 GΩ CMC 2,5·10⁻⁴ · R\n9 GΩ do 1000 GΩ CMC 2,7·10⁻² · R\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) PW-05 Kalibratory rezystancji\nKarty pomiarowe\nOscyloskopy\nSkopometry\nRezystory stale\nRezystory regulowane\nWzorce rezystancji Wzorcowanie — Rezystancja DC\nZakres:\n0,001 kΩ do 1,2 Ω CMC 2,8·10⁻⁵ · R + 7 µΩ\n1,2 Ω do 12 Ω CMC 1,9·10⁻⁵ · R + 34 µΩ\n12 Ω do 120 Ω CMC 1,7·10⁻⁵ · R + 0,1 mΩ\n0,12 kΩ do 1,2 kΩ CMC 1,5·10⁻⁵ · R + 0,9 mΩ\n1,2 kΩ do 12 kΩ CMC 1,8·10⁻⁵ · R + 9 mΩ\n12 kΩ do 120 kΩ CMC 1,8·10⁻⁵ · R + 1 Ω\n0,12 MΩ do 1,2 MΩ CMC 2,2·10⁻⁵ · R + 2,3 Ω\n1,2 MΩ do 12 MΩ CMC 2,8·10⁻⁵ · R + 0,1 kΩ\n12 MΩ do 90 MΩ CMC 2·10⁻⁴ · R\n90 MΩ do 900 MΩ CMC 6·10⁻⁴ · R\n0,9 GΩ do 9 GΩ CMC 2,5·10⁻⁴ · R\n9 GΩ do 1000 GΩ CMC 2,7·10⁻² · R\nProcedura wewnetrzna; metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) PW-05","search_en":"Resistance calibrators Data acquisition cards Oscilloscopes Scopemeters Fixed resistors Variable resistors Resistance standards Calibration — DC resistance Internal procedure; direct method; At permanent location (S) and outside of it (P) DC resistance Internal procedure direct method At permanent location (S) and outside of it (P) PW-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,001 kΩ to 1,2 Ω","cmc":"2,8·10⁻⁵ · R + 7 µΩ"},{"name":"","range":"1,2 Ω to 12 Ω","cmc":"1,9·10⁻⁵ · R + 34 µΩ"},{"name":"","range":"12 Ω to 120 Ω","cmc":"1,7·10⁻⁵ · R + 0,1 mΩ"},{"name":"","range":"0,12 kΩ to 1,2 kΩ","cmc":"1,5·10⁻⁵ · R + 0,9 mΩ"},{"name":"","range":"1,2 kΩ to 12 kΩ","cmc":"1,8·10⁻⁵ · R + 9 mΩ"},{"name":"","range":"12 kΩ to 120 kΩ","cmc":"1,8·10⁻⁵ · R + 1 Ω"},{"name":"","range":"0,12 MΩ to 1,2 MΩ","cmc":"2,2·10⁻⁵ · R + 2,3 Ω"},{"name":"","range":"1,2 MΩ to 12 MΩ","cmc":"2,8·10⁻⁵ · R + 0,1 kΩ"},{"name":"","range":"12 MΩ to 90 MΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"90 MΩ to 900 MΩ","cmc":"6·10⁻⁴ · R"},{"name":"","range":"0,9 GΩ to 9 GΩ","cmc":"2,5·10⁻⁴ · R"},{"name":"","range":"9 GΩ to 1000 GΩ","cmc":"2,7·10⁻² · R"}],"regulatory_area_de":"DC-Widerstand","search_de":"Widerstandskalibratoren Messkarten Oszilloskope Scopemeter Festwiderstände Einstellbare Widerstände Widerstandsnormale Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P) DC-Widerstand Internes Verfahren direktes Verfahren Am festen Standort (S) und außerhalb (P) PW-05","technique_de":"Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Widerstandskalibratoren\nMesskarten\nOszilloskope\nScopemeter\nFestwiderstände\nEinstellbare Widerstände\nWiderstandsnormale","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,001 kΩ to 1,2 Ω","cmc":"2,8·10⁻⁵ · R + 7 µΩ"},{"name":"","range":"1,2 Ω to 12 Ω","cmc":"1,9·10⁻⁵ · R + 34 µΩ"},{"name":"","range":"12 Ω to 120 Ω","cmc":"1,7·10⁻⁵ · R + 0,1 mΩ"},{"name":"","range":"0,12 kΩ to 1,2 kΩ","cmc":"1,5·10⁻⁵ · R + 0,9 mΩ"},{"name":"","range":"1,2 kΩ to 12 kΩ","cmc":"1,8·10⁻⁵ · R + 9 mΩ"},{"name":"","range":"12 kΩ to 120 kΩ","cmc":"1,8·10⁻⁵ · R + 1 Ω"},{"name":"","range":"0,12 MΩ to 1,2 MΩ","cmc":"2,2·10⁻⁵ · R + 2,3 Ω"},{"name":"","range":"1,2 MΩ to 12 MΩ","cmc":"2,8·10⁻⁵ · R + 0,1 kΩ"},{"name":"","range":"12 MΩ to 90 MΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"90 MΩ to 900 MΩ","cmc":"6·10⁻⁴ · R"},{"name":"","range":"0,9 GΩ to 9 GΩ","cmc":"2,5·10⁻⁴ · R"},{"name":"","range":"9 GΩ to 1000 GΩ","cmc":"2,7·10⁻² · R"}],"regulatory_area_zh":"直流电阻","search_zh":"电阻校准器 测量卡 示波器 手持示波表 固定电阻器 可调电阻器 标准电阻 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 直流电阻 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) PW-05","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电阻校准器\n测量卡\n示波器\n手持示波表\n固定电阻器\n可调电阻器\n标准电阻","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,001 kΩ to 1,2 Ω","cmc":"2,8·10⁻⁵ · R + 7 µΩ"},{"name":"","range":"1,2 Ω to 12 Ω","cmc":"1,9·10⁻⁵ · R + 34 µΩ"},{"name":"","range":"12 Ω to 120 Ω","cmc":"1,7·10⁻⁵ · R + 0,1 mΩ"},{"name":"","range":"0,12 kΩ to 1,2 kΩ","cmc":"1,5·10⁻⁵ · R + 0,9 mΩ"},{"name":"","range":"1,2 kΩ to 12 kΩ","cmc":"1,8·10⁻⁵ · R + 9 mΩ"},{"name":"","range":"12 kΩ to 120 kΩ","cmc":"1,8·10⁻⁵ · R + 1 Ω"},{"name":"","range":"0,12 MΩ to 1,2 MΩ","cmc":"2,2·10⁻⁵ · R + 2,3 Ω"},{"name":"","range":"1,2 MΩ to 12 MΩ","cmc":"2,8·10⁻⁵ · R + 0,1 kΩ"},{"name":"","range":"12 MΩ to 90 MΩ","cmc":"2·10⁻⁴ · R"},{"name":"","range":"90 MΩ to 900 MΩ","cmc":"6·10⁻⁴ · R"},{"name":"","range":"0,9 GΩ to 9 GΩ","cmc":"2,5·10⁻⁴ · R"},{"name":"","range":"9 GΩ to 1000 GΩ","cmc":"2,7·10⁻² · R"}],"regulatory_area_cs":"Odpor DC","search_cs":"Kalibrátory odporu Měřicí karty Osciloskopy Skopmetry Pevné rezistory Nastavitelné rezistory Etalony odporu Kalibrace — Odpor DC Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Odpor DC Vnitřní postup přímá metoda V trvalé lokalitě (S) i mimo ni (P) PW-05","technique_cs":"Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kalibrátory odporu\nMěřicí karty\nOsciloskopy\nSkopmetry\nPevné rezistory\nNastavitelné rezistory\nEtalony odporu"},{"_id":"0e76f7e1b39a0eae35e69dcc","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Mierniki parametrów sieci\nMierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMostki\nMultimetry","test_object_en":"Power network parameter meters\nAnalogue ohmmeters\nDigital ohmmeters\nBridges\nMultimeters","methodology":"Wzorcowanie — Rezystancja AC","methodology_en":"Calibration — AC resistance","parameters":[{"name":"50 Hz","range":"0,1 Ω do 100 kΩ","cmc":"5·10⁻⁴ · R"},{"name":"50 Hz do 1 kHz","range":"0,001 Ω; 0,01 Ω; 0,1 Ω","cmc":"3·10⁻³ · R"},{"name":"50 Hz do 1 kHz","range":"1 Ω; 10 Ω; 100 Ω; 1 kΩ;","cmc":"2·10⁻³ · R"},{"name":"50 Hz do 1 kHz","range":"10 kΩ; 100 kΩ","cmc":"2·10⁻³ · R"}],"parameters_en":[{"name":"50 Hz","range":"0,1 Ω to 100 kΩ","cmc":"5·10⁻⁴ · R"},{"name":"50 Hz to 1 kHz","range":"0,001 Ω; 0,01 Ω; 0,1 Ω","cmc":"3·10⁻³ · R"},{"name":"50 Hz to 1 kHz","range":"1 Ω; 10 Ω; 100 Ω; 1 kΩ;","cmc":"2·10⁻³ · R"},{"name":"50 Hz to 1 kHz","range":"10 kΩ; 100 kΩ","cmc":"2·10⁻³ · R"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja AC\nZakres:\n50 Hz 0,1 Ω do 100 kΩ CMC 5·10⁻⁴ · R\n50 Hz do 1 kHz 0,001 Ω; 0,01 Ω; 0,1 Ω CMC 3·10⁻³ · R\n50 Hz do 1 kHz 1 Ω; 10 Ω; 100 Ω; 1 kΩ; CMC 2·10⁻³ · R\n50 Hz do 1 kHz 10 kΩ; 100 kΩ CMC 2·10⁻³ · R\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-03","norm_bases":["PW-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja AC","regulatory_area_en":"AC resistance","outside_premises":true,"location_of_activity":"S, P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured quantity (Ω)","search_text":"Mierniki parametrów sieci\nMierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMostki\nMultimetry Wzorcowanie — Rezystancja AC\nZakres:\n50 Hz 0,1 Ω do 100 kΩ CMC 5·10⁻⁴ · R\n50 Hz do 1 kHz 0,001 Ω; 0,01 Ω; 0,1 Ω CMC 3·10⁻³ · R\n50 Hz do 1 kHz 1 Ω; 10 Ω; 100 Ω; 1 kΩ; CMC 2·10⁻³ · R\n50 Hz do 1 kHz 10 kΩ; 100 kΩ CMC 2·10⁻³ · R\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) PW-03 Mierniki parametrow sieci\nMierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMostki\nMultimetry Wzorcowanie — Rezystancja AC\nZakres:\n50 Hz 0,1 Ω do 100 kΩ CMC 5·10⁻⁴ · R\n50 Hz do 1 kHz 0,001 Ω; 0,01 Ω; 0,1 Ω CMC 3·10⁻³ · R\n50 Hz do 1 kHz 1 Ω; 10 Ω; 100 Ω; 1 kΩ; CMC 2·10⁻³ · R\n50 Hz do 1 kHz 10 kΩ; 100 kΩ CMC 2·10⁻³ · R\nProcedura wewnetrzna; metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) PW-03","search_en":"Power network parameter meters Analogue ohmmeters Digital ohmmeters Bridges Multimeters Calibration — AC resistance Internal procedure; direct method; At permanent location (S) and outside of it (P) AC resistance Internal procedure direct method At permanent location (S) and outside of it (P) 50 Hz 50 Hz to 1 kHz 50 Hz to 1 kHz 50 Hz to 1 kHz PW-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstromwiderstand","parameters_de":[{"name":"50 Hz","range":"0,1 Ω to 100 kΩ","cmc":"5·10⁻⁴ · R"},{"name":"50 Hz bis 1 kHz","range":"0,001 Ω; 0,01 Ω; 0,1 Ω","cmc":"3·10⁻³ · R"},{"name":"50 Hz bis 1 kHz","range":"1 Ω; 10 Ω; 100 Ω; 1 kΩ;","cmc":"2·10⁻³ · R"},{"name":"50 Hz bis 1 kHz","range":"10 kΩ; 100 kΩ","cmc":"2·10⁻³ · R"}],"regulatory_area_de":"AC-Widerstand","search_de":"Netzparametermessgeräte Analoge Widerstandsmessgeräte Digitale Widerstandsmessgeräte Messbrücken Multimeter Kalibrierung — Wechselstromwiderstand Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Widerstand Internes Verfahren direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz 50 Hz bis 1 kHz 50 Hz bis 1 kHz 50 Hz bis 1 kHz PW-03","technique_de":"Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzparametermessgeräte\nAnaloge Widerstandsmessgeräte\nDigitale Widerstandsmessgeräte\nMessbrücken\nMultimeter","methodology_zh":"校准 — 交流电阻","parameters_zh":[{"name":"50 Hz","range":"0,1 Ω to 100 kΩ","cmc":"5·10⁻⁴ · R"},{"name":"50 Hz 至 1 kHz","range":"0,001 Ω; 0,01 Ω; 0,1 Ω","cmc":"3·10⁻³ · R"},{"name":"50 Hz 至 1 kHz","range":"1 Ω; 10 Ω; 100 Ω; 1 kΩ;","cmc":"2·10⁻³ · R"},{"name":"50 Hz 至 1 kHz","range":"10 kΩ; 100 kΩ","cmc":"2·10⁻³ · R"}],"regulatory_area_zh":"交流电阻","search_zh":"电网参数测量仪 模拟式电阻表 数字电阻测量仪 电桥 万用表 校准 — 交流电阻 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电阻 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 Hz 50 Hz 至 1 kHz 50 Hz 至 1 kHz 50 Hz 至 1 kHz PW-03","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电网参数测量仪\n模拟式电阻表\n数字电阻测量仪\n电桥\n万用表","methodology_cs":"Kalibrace — Odpor AC","parameters_cs":[{"name":"50 Hz","range":"0,1 Ω to 100 kΩ","cmc":"5·10⁻⁴ · R"},{"name":"50 Hz až 1 kHz","range":"0,001 Ω; 0,01 Ω; 0,1 Ω","cmc":"3·10⁻³ · R"},{"name":"50 Hz až 1 kHz","range":"1 Ω; 10 Ω; 100 Ω; 1 kΩ;","cmc":"2·10⁻³ · R"},{"name":"50 Hz až 1 kHz","range":"10 kΩ; 100 kΩ","cmc":"2·10⁻³ · R"}],"regulatory_area_cs":"Odpor AC","search_cs":"Měřiče parametrů sítě Analogové měřiče odporu Digitální měřiče odporu Můstky Multimetry Kalibrace — Odpor AC Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Odpor AC Vnitřní postup přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 Hz 50 Hz až 1 kHz 50 Hz až 1 kHz 50 Hz až 1 kHz PW-03","technique_cs":"Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče parametrů sítě\nAnalogové měřiče odporu\nDigitální měřiče odporu\nMůstky\nMultimetry"},{"_id":"f36570b6d33bfc85b02c97a9","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Mierniki rezystancji przewodu ochronnego (PE)\nMierniki parametrów sieci\nTestery bezpieczeństwa elektrycznego","test_object_en":"Protective conductor (PE) resistance meters\nPower network parameter meters\nElectrical safety testers","methodology":"Wzorcowanie — Rezystancja AC","methodology_en":"Calibration — AC resistance","parameters":[{"name":"50 Hz","range":"10 mΩ do 1000 mΩ","cmc":"5·10⁻³ · R"}],"parameters_en":[{"name":"50 Hz","range":"10 mΩ to 1000 mΩ","cmc":"5·10⁻³ · R"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja AC\n50 Hz 10 mΩ do 1000 mΩ CMC 5·10⁻³ · R\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-03","norm_bases":["PW-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja AC","regulatory_area_en":"AC resistance","outside_premises":true,"location_of_activity":"S, P","note":"R – wielkość mierzona (Ω)","note_en":"R – measured quantity (Ω)","search_text":"Mierniki rezystancji przewodu ochronnego (PE)\nMierniki parametrów sieci\nTestery bezpieczeństwa elektrycznego Wzorcowanie — Rezystancja AC\n50 Hz 10 mΩ do 1000 mΩ CMC 5·10⁻³ · R\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) PW-03 Mierniki rezystancji przewodu ochronnego (PE)\nMierniki parametrow sieci\nTestery bezpieczenstwa elektrycznego Wzorcowanie — Rezystancja AC\n50 Hz 10 mΩ do 1000 mΩ CMC 5·10⁻³ · R\nProcedura wewnetrzna; metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) PW-03","search_en":"Protective conductor (PE) resistance meters Power network parameter meters Electrical safety testers Calibration — AC resistance Internal procedure; direct method; At permanent location (S) and outside of it (P) AC resistance Internal procedure direct method At permanent location (S) and outside of it (P) 50 Hz PW-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstromwiderstand","parameters_de":[{"name":"50 Hz","range":"10 mΩ to 1000 mΩ","cmc":"5·10⁻³ · R"}],"regulatory_area_de":"AC-Widerstand","search_de":"Messgeräte für den Schutzleiterwiderstand (PE) Netzparametermessgeräte Prüfgeräte für elektrische Sicherheit Kalibrierung — Wechselstromwiderstand Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P) AC-Widerstand Internes Verfahren direktes Verfahren Am festen Standort (S) und außerhalb (P) 50 Hz PW-03","technique_de":"Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Messgeräte für den Schutzleiterwiderstand (PE)\nNetzparametermessgeräte\nPrüfgeräte für elektrische Sicherheit","methodology_zh":"校准 — 交流电阻","parameters_zh":[{"name":"50 Hz","range":"10 mΩ to 1000 mΩ","cmc":"5·10⁻³ · R"}],"regulatory_area_zh":"交流电阻","search_zh":"保护导体 (PE) 电阻测量仪 电网参数测量仪 电气安全测试仪 校准 — 交流电阻 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 交流电阻 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 50 Hz PW-03","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"保护导体 (PE) 电阻测量仪\n电网参数测量仪\n电气安全测试仪","methodology_cs":"Kalibrace — Odpor AC","parameters_cs":[{"name":"50 Hz","range":"10 mΩ to 1000 mΩ","cmc":"5·10⁻³ · R"}],"regulatory_area_cs":"Odpor AC","search_cs":"Měřiče odporu ochranného vodiče (PE) Měřiče parametrů sítě Testery elektrické bezpečnosti Kalibrace — Odpor AC Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Odpor AC Vnitřní postup přímá metoda V trvalé lokalitě (S) i mimo ni (P) 50 Hz PW-03","technique_cs":"Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče odporu ochranného vodiče (PE)\nMěřiče parametrů sítě\nTestery elektrické bezpečnosti"},{"_id":"f579ac18189deefc93c21143","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Kilowoltomierze","test_object_en":"Kilovoltmeters","methodology":"Wzorcowanie — Wysokie napięcie i prąd","methodology_en":"Calibration — High voltage and current","parameters":[{"name":"","range":"0,01 kV do 6 kV","cmc":"1·10⁻³ · U"}],"parameters_en":[{"name":"","range":"0,01 kV to 6 kV","cmc":"1·10⁻³ · U"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie DC; W stałej lokalizacji (S)","technique_en":"Internal procedure; direct method\nhigh DC voltage; At permanent location (S)","techniques":["Procedura wewnętrzna","metoda bezpośrednia\nwysokie napięcie DC","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","direct method\nhigh DC voltage","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wysokie napięcie i prąd\n0,01 kV do 6 kV CMC 1·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie DC; W stałej lokalizacji (S)","reference":"PW-06","norm_bases":["PW-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wysokie napięcie i prąd","regulatory_area_en":"High voltage and current","outside_premises":false,"location_of_activity":"S","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Kilowoltomierze Wzorcowanie — Wysokie napięcie i prąd\n0,01 kV do 6 kV CMC 1·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie DC; W stałej lokalizacji (S) PW-06 Kilowoltomierze Wzorcowanie — Wysokie napiecie i prad\n0,01 kV do 6 kV CMC 1·10⁻³ · U\nProcedura wewnetrzna; metoda bezposrednia\nwysokie napiecie DC; W stalej lokalizacji (S) PW-06","search_en":"Kilovoltmeters Calibration — High voltage and current Internal procedure; direct method high DC voltage; At permanent location (S) High voltage and current Internal procedure direct method high DC voltage At permanent location (S) PW-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Hochspannung und Strom","parameters_de":[{"name":"","range":"0,01 kV to 6 kV","cmc":"1·10⁻³ · U"}],"regulatory_area_de":"Hochspannung und Strom","search_de":"Kilovoltmeter Kalibrierung — Hochspannung und Strom Interne Verfahrensanweisung; direktes Verfahren Hochspannung DC; Am festen Standort (S) Hochspannung und Strom Internes Verfahren direktes Verfahren Hochspannung DC Am festen Standort (S) PW-06","technique_de":"Interne Verfahrensanweisung; direktes Verfahren\nHochspannung DC; Am festen Standort (S)","techniques_de":["Internes Verfahren","direktes Verfahren\nHochspannung DC","Am festen Standort (S)"],"test_object_de":"Kilovoltmeter","methodology_zh":"校准 — 高电压和大电流","parameters_zh":[{"name":"","range":"0,01 kV to 6 kV","cmc":"1·10⁻³ · U"}],"regulatory_area_zh":"高电压和大电流","search_zh":"千伏表 校准 — 高电压和大电流 内部程序；直接法 直流高压；在固定地点 (S) 高电压和大电流 内部程序 直接法 直流高压 在固定地点 (S) PW-06","technique_zh":"内部程序；直接法\n直流高压；在固定地点 (S)","techniques_zh":["内部程序","直接法\n直流高压","在固定地点 (S)"],"test_object_zh":"千伏表","methodology_cs":"Kalibrace — Vysoké napětí a proud","parameters_cs":[{"name":"","range":"0,01 kV to 6 kV","cmc":"1·10⁻³ · U"}],"regulatory_area_cs":"Vysoké napětí a proud","search_cs":"Kilovoltmetry Kalibrace — Vysoké napětí a proud Vnitřní postup; přímá metoda vysoké napětí DC; Ve stálé lokalitě (S) Vysoké napětí a proud Vnitřní postup přímá metoda vysoké napětí DC Ve stálé lokalitě (S) PW-06","technique_cs":"Vnitřní postup; přímá metoda\nvysoké napětí DC; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","přímá metoda\nvysoké napětí DC","Ve stálé lokalitě (S)"],"test_object_cs":"Kilovoltmetry"},{"_id":"99bfd80f7b07a9fa056603e4","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Mierniki parametrów sieci\nPróbniki przebicia\nTestery bezpieczeństwa elektrycznego\nŹródła napięcia","test_object_en":"Power network parameter meters\nBreakdown testers\nElectrical safety testers\nVoltage sources","methodology":"Wzorcowanie — Wysokie napięcie i prąd","methodology_en":"Calibration — High voltage and current","parameters":[{"name":"","range":"0,01 kV do 40 kV","cmc":"1·10⁻³ · U"}],"parameters_en":[{"name":"","range":"0,01 kV to 40 kV","cmc":"1·10⁻³ · U"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie DC; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; direct method\nhigh DC voltage; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","metoda bezpośrednia\nwysokie napięcie DC","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","direct method\nhigh DC voltage","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wysokie napięcie i prąd\n0,01 kV do 40 kV CMC 1·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie DC; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-06","norm_bases":["PW-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wysokie napięcie i prąd","regulatory_area_en":"High voltage and current","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Mierniki parametrów sieci\nPróbniki przebicia\nTestery bezpieczeństwa elektrycznego\nŹródła napięcia Wzorcowanie — Wysokie napięcie i prąd\n0,01 kV do 40 kV CMC 1·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie DC; W stałej lokalizacji (S) i poza nią (P) PW-06 Mierniki parametrow sieci\nProbniki przebicia\nTestery bezpieczenstwa elektrycznego\nZrodla napiecia Wzorcowanie — Wysokie napiecie i prad\n0,01 kV do 40 kV CMC 1·10⁻³ · U\nProcedura wewnetrzna; metoda bezposrednia\nwysokie napiecie DC; W stalej lokalizacji (S) i poza nia (P) PW-06","search_en":"Power network parameter meters Breakdown testers Electrical safety testers Voltage sources Calibration — High voltage and current Internal procedure; direct method high DC voltage; At permanent location (S) and outside of it (P) High voltage and current Internal procedure direct method high DC voltage At permanent location (S) and outside of it (P) PW-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Hochspannung und Strom","parameters_de":[{"name":"","range":"0,01 kV to 40 kV","cmc":"1·10⁻³ · U"}],"regulatory_area_de":"Hochspannung und Strom","search_de":"Netzparametermessgeräte Durchschlagprüfgeräte Prüfgeräte für elektrische Sicherheit Spannungsquellen Kalibrierung — Hochspannung und Strom Interne Verfahrensanweisung; direktes Verfahren Hochspannung DC; Am festen Standort (S) und außerhalb (P) Hochspannung und Strom Internes Verfahren direktes Verfahren Hochspannung DC Am festen Standort (S) und außerhalb (P) PW-06","technique_de":"Interne Verfahrensanweisung; direktes Verfahren\nHochspannung DC; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","direktes Verfahren\nHochspannung DC","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzparametermessgeräte\nDurchschlagprüfgeräte\nPrüfgeräte für elektrische Sicherheit\nSpannungsquellen","methodology_zh":"校准 — 高电压和大电流","parameters_zh":[{"name":"","range":"0,01 kV to 40 kV","cmc":"1·10⁻³ · U"}],"regulatory_area_zh":"高电压和大电流","search_zh":"电网参数测量仪 击穿测试仪 电气安全测试仪 电压源 校准 — 高电压和大电流 内部程序；直接法 直流高压；在固定地点 (S) 及固定地点以外 (P) 高电压和大电流 内部程序 直接法 直流高压 在固定地点 (S) 及固定地点以外 (P) PW-06","technique_zh":"内部程序；直接法\n直流高压；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法\n直流高压","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电网参数测量仪\n击穿测试仪\n电气安全测试仪\n电压源","methodology_cs":"Kalibrace — Vysoké napětí a proud","parameters_cs":[{"name":"","range":"0,01 kV to 40 kV","cmc":"1·10⁻³ · U"}],"regulatory_area_cs":"Vysoké napětí a proud","search_cs":"Měřiče parametrů sítě Zkoušečky průrazu Testery elektrické bezpečnosti Zdroje napětí Kalibrace — Vysoké napětí a proud Vnitřní postup; přímá metoda vysoké napětí DC; Ve stálé lokalitě (S) a mimo ni (P) Vysoké napětí a proud Vnitřní postup přímá metoda vysoké napětí DC V trvalé lokalitě (S) i mimo ni (P) PW-06","technique_cs":"Vnitřní postup; přímá metoda\nvysoké napětí DC; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","přímá metoda\nvysoké napětí DC","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče parametrů sítě\nZkoušečky průrazu\nTestery elektrické bezpečnosti\nZdroje napětí"},{"_id":"981b432d860c1238e0b76c5b","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Kilowoltomierze","test_object_en":"Kilovoltmeters","methodology":"Wzorcowanie — Wysokie napięcie i prąd","methodology_en":"Calibration — High voltage and current","parameters":[{"name":"50 kHz do 60 kHz","range":"0,01 kV do 5 kV","cmc":"2,5·10⁻³ · U"}],"parameters_en":[{"name":"50 kHz to 60 kHz","range":"0,01 kV to 5 kV","cmc":"2,5·10⁻³ · U"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie AC; W stałej lokalizacji (S)","technique_en":"Internal procedure; direct method\nhigh AC voltage; At permanent location (S)","techniques":["Procedura wewnętrzna","metoda bezpośrednia\nwysokie napięcie AC","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","direct method\nhigh AC voltage","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wysokie napięcie i prąd\n50 kHz do 60 kHz 0,01 kV do 5 kV CMC 2,5·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie AC; W stałej lokalizacji (S)","reference":"PW-06","norm_bases":["PW-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wysokie napięcie i prąd","regulatory_area_en":"High voltage and current","outside_premises":false,"location_of_activity":"S","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Kilowoltomierze Wzorcowanie — Wysokie napięcie i prąd\n50 kHz do 60 kHz 0,01 kV do 5 kV CMC 2,5·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie AC; W stałej lokalizacji (S) PW-06 Kilowoltomierze Wzorcowanie — Wysokie napiecie i prad\n50 kHz do 60 kHz 0,01 kV do 5 kV CMC 2,5·10⁻³ · U\nProcedura wewnetrzna; metoda bezposrednia\nwysokie napiecie AC; W stalej lokalizacji (S) PW-06","search_en":"Kilovoltmeters Calibration — High voltage and current Internal procedure; direct method high AC voltage; At permanent location (S) High voltage and current Internal procedure direct method high AC voltage At permanent location (S) 50 kHz to 60 kHz PW-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Hochspannung und Strom","parameters_de":[{"name":"50 kHz bis 60 kHz","range":"0,01 kV to 5 kV","cmc":"2,5·10⁻³ · U"}],"regulatory_area_de":"Hochspannung und Strom","search_de":"Kilovoltmeter Kalibrierung — Hochspannung und Strom Interne Verfahrensanweisung; direktes Verfahren Hochspannung AC; Am festen Standort (S) Hochspannung und Strom Internes Verfahren direktes Verfahren Hochspannung AC Am festen Standort (S) 50 kHz bis 60 kHz PW-06","technique_de":"Interne Verfahrensanweisung; direktes Verfahren\nHochspannung AC; Am festen Standort (S)","techniques_de":["Internes Verfahren","direktes Verfahren\nHochspannung AC","Am festen Standort (S)"],"test_object_de":"Kilovoltmeter","methodology_zh":"校准 — 高电压和大电流","parameters_zh":[{"name":"50 kHz 至 60 kHz","range":"0,01 kV to 5 kV","cmc":"2,5·10⁻³ · U"}],"regulatory_area_zh":"高电压和大电流","search_zh":"千伏表 校准 — 高电压和大电流 内部程序；直接法 交流高压；在固定地点 (S) 高电压和大电流 内部程序 直接法 交流高压 在固定地点 (S) 50 kHz 至 60 kHz PW-06","technique_zh":"内部程序；直接法\n交流高压；在固定地点 (S)","techniques_zh":["内部程序","直接法\n交流高压","在固定地点 (S)"],"test_object_zh":"千伏表","methodology_cs":"Kalibrace — Vysoké napětí a proud","parameters_cs":[{"name":"50 kHz až 60 kHz","range":"0,01 kV to 5 kV","cmc":"2,5·10⁻³ · U"}],"regulatory_area_cs":"Vysoké napětí a proud","search_cs":"Kilovoltmetry Kalibrace — Vysoké napětí a proud Vnitřní postup; přímá metoda vysoké napětí AC; Ve stálé lokalitě (S) Vysoké napětí a proud Vnitřní postup přímá metoda vysoké napětí AC Ve stálé lokalitě (S) 50 kHz až 60 kHz PW-06","technique_cs":"Vnitřní postup; přímá metoda\nvysoké napětí AC; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","přímá metoda\nvysoké napětí AC","Ve stálé lokalitě (S)"],"test_object_cs":"Kilovoltmetry"},{"_id":"7b2581d3b1620778161a5af5","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Mierniki parametrów sieci\nPróbniki przebicia\nTestery bezpieczeństwa elektrycznego\nŹródła napięcia","test_object_en":"Power network parameter meters\nBreakdown testers\nElectrical safety testers\nVoltage sources","methodology":"Wzorcowanie — Wysokie napięcie i prąd","methodology_en":"Calibration — High voltage and current","parameters":[{"name":"50 kHz do 60kHz","range":"0,01 kV do 40 kV","cmc":"2,5·10⁻³ · U"}],"parameters_en":[{"name":"50 kHz to 60kHz","range":"0,01 kV to 40 kV","cmc":"2,5·10⁻³ · U"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie AC; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; direct method\nhigh AC voltage; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","metoda bezpośrednia\nwysokie napięcie AC","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","direct method\nhigh AC voltage","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wysokie napięcie i prąd\n50 kHz do 60kHz 0,01 kV do 40 kV CMC 2,5·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie AC; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-06","norm_bases":["PW-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wysokie napięcie i prąd","regulatory_area_en":"High voltage and current","outside_premises":true,"location_of_activity":"S, P","note":"U – wielkość mierzona (V)","note_en":"U – measured quantity (V)","search_text":"Mierniki parametrów sieci\nPróbniki przebicia\nTestery bezpieczeństwa elektrycznego\nŹródła napięcia Wzorcowanie — Wysokie napięcie i prąd\n50 kHz do 60kHz 0,01 kV do 40 kV CMC 2,5·10⁻³ · U\nProcedura wewnętrzna; metoda bezpośrednia\nwysokie napięcie AC; W stałej lokalizacji (S) i poza nią (P) PW-06 Mierniki parametrow sieci\nProbniki przebicia\nTestery bezpieczenstwa elektrycznego\nZrodla napiecia Wzorcowanie — Wysokie napiecie i prad\n50 kHz do 60kHz 0,01 kV do 40 kV CMC 2,5·10⁻³ · U\nProcedura wewnetrzna; metoda bezposrednia\nwysokie napiecie AC; W stalej lokalizacji (S) i poza nia (P) PW-06","search_en":"Power network parameter meters Breakdown testers Electrical safety testers Voltage sources Calibration — High voltage and current Internal procedure; direct method high AC voltage; At permanent location (S) and outside of it (P) High voltage and current Internal procedure direct method high AC voltage At permanent location (S) and outside of it (P) 50 kHz to 60kHz PW-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Hochspannung und Strom","parameters_de":[{"name":"50 kHz bis 60kHz","range":"0,01 kV to 40 kV","cmc":"2,5·10⁻³ · U"}],"regulatory_area_de":"Hochspannung und Strom","search_de":"Netzparametermessgeräte Durchschlagprüfgeräte Prüfgeräte für elektrische Sicherheit Spannungsquellen Kalibrierung — Hochspannung und Strom Interne Verfahrensanweisung; direktes Verfahren Hochspannung AC; Am festen Standort (S) und außerhalb (P) Hochspannung und Strom Internes Verfahren direktes Verfahren Hochspannung AC Am festen Standort (S) und außerhalb (P) 50 kHz bis 60kHz PW-06","technique_de":"Interne Verfahrensanweisung; direktes Verfahren\nHochspannung AC; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","direktes Verfahren\nHochspannung AC","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Netzparametermessgeräte\nDurchschlagprüfgeräte\nPrüfgeräte für elektrische Sicherheit\nSpannungsquellen","methodology_zh":"校准 — 高电压和大电流","parameters_zh":[{"name":"50 kHz 至 60kHz","range":"0,01 kV to 40 kV","cmc":"2,5·10⁻³ · U"}],"regulatory_area_zh":"高电压和大电流","search_zh":"电网参数测量仪 击穿测试仪 电气安全测试仪 电压源 校准 — 高电压和大电流 内部程序；直接法 交流高压；在固定地点 (S) 及固定地点以外 (P) 高电压和大电流 内部程序 直接法 交流高压 在固定地点 (S) 及固定地点以外 (P) 50 kHz 至 60kHz PW-06","technique_zh":"内部程序；直接法\n交流高压；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法\n交流高压","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"电网参数测量仪\n击穿测试仪\n电气安全测试仪\n电压源","methodology_cs":"Kalibrace — Vysoké napětí a proud","parameters_cs":[{"name":"50 kHz až 60kHz","range":"0,01 kV to 40 kV","cmc":"2,5·10⁻³ · U"}],"regulatory_area_cs":"Vysoké napětí a proud","search_cs":"Měřiče parametrů sítě Zkoušečky průrazu Testery elektrické bezpečnosti Zdroje napětí Kalibrace — Vysoké napětí a proud Vnitřní postup; přímá metoda vysoké napětí AC; Ve stálé lokalitě (S) a mimo ni (P) Vysoké napětí a proud Vnitřní postup přímá metoda vysoké napětí AC V trvalé lokalitě (S) i mimo ni (P) 50 kHz až 60kHz PW-06","technique_cs":"Vnitřní postup; přímá metoda\nvysoké napětí AC; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","přímá metoda\nvysoké napětí AC","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče parametrů sítě\nZkoušečky průrazu\nTestery elektrické bezpečnosti\nZdroje napětí"},{"_id":"81f8117aab2bd7164b205fc6","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Mierniki okresu\nGeneratory okresu\nOscyloskopy","test_object_en":"Period meters\nPeriod generators\nOscilloscopes","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"3,3 ns do 1 s","cmc":"1,5·10⁻⁶ · t + 100 ps"}],"parameters_en":[{"name":"","range":"3,3 ns to 1 s","cmc":"1,5·10⁻⁶ · t + 100 ps"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n3,3 ns do 1 s CMC 1,5·10⁻⁶ · t + 100 ps\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-01","norm_bases":["PW-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":true,"location_of_activity":"S, P","note":"t – wielkość mierzona (s)","note_en":"t – measured quantity (s)","search_text":"Mierniki okresu\nGeneratory okresu\nOscyloskopy Wzorcowanie — Czas (przedział czasu)\n3,3 ns do 1 s CMC 1,5·10⁻⁶ · t + 100 ps\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) PW-01 Mierniki okresu\nGeneratory okresu\nOscyloskopy Wzorcowanie — Czas (przedzial czasu)\n3,3 ns do 1 s CMC 1,5·10⁻⁶ · t + 100 ps\nProcedura wewnetrzna; metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) PW-01","search_en":"Period meters Period generators Oscilloscopes Calibration — Time (time interval) Internal procedure; direct method; At permanent location (S) and outside of it (P) Time (time interval) Internal procedure direct method At permanent location (S) and outside of it (P) PW-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"3,3 ns to 1 s","cmc":"1,5·10⁻⁶ · t + 100 ps"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Periodendauermesser Periodengeneratoren Oszilloskope Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P) Zeit (Zeitintervall) Internes Verfahren direktes Verfahren Am festen Standort (S) und außerhalb (P) PW-01","technique_de":"Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Periodendauermesser\nPeriodengeneratoren\nOszilloskope","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"3,3 ns to 1 s","cmc":"1,5·10⁻⁶ · t + 100 ps"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"周期测量仪 周期发生器 示波器 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) PW-01","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"周期测量仪\n周期发生器\n示波器","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"3,3 ns to 1 s","cmc":"1,5·10⁻⁶ · t + 100 ps"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče periody Generátory periody Osciloskopy Kalibrace — Čas (časový interval) Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Čas (časový interval) Vnitřní postup přímá metoda V trvalé lokalitě (S) i mimo ni (P) PW-01","technique_cs":"Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Měřiče periody\nGenerátory periody\nOsciloskopy"},{"_id":"580804845b09015e52319b92","lab_id":"6af798960ecd48de0c7068a2","country":"PL","accr_number":"AP 165","accr_body":"PCA","test_object":"Generatory częstotliwości\nGeneratory kwarcowe\nMierniki częstotliwości cyfrowe\nOscyloskopy","test_object_en":"Frequency generators\nQuartz generators\nDigital frequency meters\nOscilloscopes","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"1 Hz do 2,7 GHz","cmc":"1·10⁻⁶ · f + 15 µHz"}],"parameters_en":[{"name":"","range":"1 Hz to 2,7 GHz","cmc":"1·10⁻⁶ · f + 15 µHz"}],"technique":"Procedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n1 Hz do 2,7 GHz CMC 1·10⁻⁶ · f + 15 µHz\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"PW-01","norm_bases":["PW-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":true,"location_of_activity":"S, P","note":"f – wielkość mierzona (Hz)","note_en":"f – measured quantity (Hz)","search_text":"Generatory częstotliwości\nGeneratory kwarcowe\nMierniki częstotliwości cyfrowe\nOscyloskopy Wzorcowanie — Częstotliwość\n1 Hz do 2,7 GHz CMC 1·10⁻⁶ · f + 15 µHz\nProcedura wewnętrzna; metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) PW-01 Generatory czestotliwosci\nGeneratory kwarcowe\nMierniki czestotliwosci cyfrowe\nOscyloskopy Wzorcowanie — Czestotliwosc\n1 Hz do 2,7 GHz CMC 1·10⁻⁶ · f + 15 µHz\nProcedura wewnetrzna; metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) PW-01","search_en":"Frequency generators Quartz generators Digital frequency meters Oscilloscopes Calibration — Frequency Internal procedure; direct method; At permanent location (S) and outside of it (P) Frequency Internal procedure direct method At permanent location (S) and outside of it (P) PW-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"1 Hz to 2,7 GHz","cmc":"1·10⁻⁶ · f + 15 µHz"}],"regulatory_area_de":"Frequenz","search_de":"Frequenzgeneratoren Quarzgeneratoren Digitale Frequenzmesser Oszilloskope Kalibrierung — Frequenz Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P) Frequenz Internes Verfahren direktes Verfahren Am festen Standort (S) und außerhalb (P) PW-01","technique_de":"Interne Verfahrensanweisung; direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Frequenzgeneratoren\nQuarzgeneratoren\nDigitale Frequenzmesser\nOszilloskope","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"1 Hz to 2,7 GHz","cmc":"1·10⁻⁶ · f + 15 µHz"}],"regulatory_area_zh":"频率","search_zh":"频率发生器 石英发生器 数字频率计 示波器 校准 — 频率 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 频率 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) PW-01","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"频率发生器\n石英发生器\n数字频率计\n示波器","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"1 Hz to 2,7 GHz","cmc":"1·10⁻⁶ · f + 15 µHz"}],"regulatory_area_cs":"Frekvence","search_cs":"Generátory kmitočtu Krystalové generátory Digitální čítače kmitočtu Osciloskopy Kalibrace — Kmitočet Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Frekvence Vnitřní postup přímá metoda V trvalé lokalitě (S) i mimo ni (P) PW-01","technique_cs":"Vnitřní postup; přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Generátory kmitočtu\nKrystalové generátory\nDigitální čítače kmitočtu\nOsciloskopy"}],"has_pdf":true}