🇵🇱 Krajowe Usługi Metrologiczne M. Koziorowski, P. Koziorowski s.c. PL

PCA AP 162 • Łódź, Poland • 111 calibration items

Metrology & calibration

Krajowe Usługi Metrologiczne M. Koziorowski, P. Koziorowski s.c. is a calibration laboratory accredited by PCA under number AP 162 (Łódź, Poland). Its accreditation scope covers 111 calibration items in the following areas: Metrology & calibration. Calibrated items include: Digital dial gauges, Analogue dial gauges, Feeler gauges, Analogue lever dial gauges. Most frequently used calibration principles: Internal procedure; Direct method using gauge blocks; At permanent…, Internal procedure; Direct method using a MAHR OPTIMAR 100 instrume…, Internal procedure; Direct method using a Mitutoyo micrometer head;….

At a glance

  • Accreditation number: PCA AP 162
  • Calibration items in scope: 111
  • Types of calibrated items: 95
  • Calibration principles used: 42
  • City: Łódź, Poland
  • Valid until: 28-04-2028
Accreditation number
AP 162
Accreditation body
PCA
Address
ul. Demokratyczna 117, 93-348 Łódź
City
Łódź, Poland
Division
Calibration Laboratory
Valid until
28-04-2028

What this laboratory calibrates (95)

Calibration principles (42)

Certificate information

Issue date
10.03.2026
Issue no.
13
Certificate date
23.04.2020
Accreditation cycle
18.03.2024 — 28.04.2028
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (111)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The CMC uncertainty is expressed in measurand units. A CMC uncertainty value expressed as the equation Q[a; b] means the root sum of squares of the terms in brackets: Q[a; b] = (a² + b²)^1/2.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Analogue dial gauges
– scale interval 0,01 mm
Calibration — Length
0 mm do 10 mm · CMC 2,5 µm 0 mm do 30 mm · CMC 2,9 µm 0 mm to 50 mm · CMC 3,3 µm
Length
Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Internal procedure IW/KUM/05/01
2 Analogue lever dial gauges
– scale interval 0,01 mm
Calibration — Length
0 mm to 3 mm · CMC 2,5 µm
Length
Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Internal procedure IW/KUM/05/01
3 Analogue dial gauges
– scale interval (0,002; 0,001) mm
Calibration — Length
0 mm to 5 mm · CMC 1,8 µm
Length
Internal procedure; Direct method using a Mitutoyo Type 521-105 instrument; At permanent location (S) Internal procedure IW/KUM/06/01
4 Analogue lever dial gauges
– scale interval (0,002; 0,001) mm
Calibration — Length
0 mm to 0,6 mm · CMC 1,8 µm
Length
Internal procedure; Direct method using a Mitutoyo Type 521-105 instrument; At permanent location (S) Internal procedure IW/KUM/06/01
5 Analogue dial gauges
– scale interval 0,1 mm
Calibration — Length
0 mm to 50 mm · CMC 6 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
6 Analogue dial gauges
– scale interval (0,02; 0,01) mm
Calibration — Length
0 mm do 10 mm · CMC 1,0 µm 0 mm do 30 mm · CMC 1,5 µm 0 mm to 50 mm · CMC 2,1 µm 0 mm do 80 mm · CMC 3,1 µm 0 mm do 100 mm · CMC 3,9 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
7 Analogue dial gauges
– scale interval (0,005; 0,002; 0,001) mm
Calibration — Length
0 mm to 5 mm · CMC 0,5 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
8 Analogue lever dial gauges
– scale interval (0,02; 0,01) mm
Calibration — Length
0 mm to 3 mm · CMC 0,9 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
9 Analogue lever dial gauges
– scale interval (0,005; 0,002; 0,001) mm
Calibration — Length
0 mm to 0,6 mm · CMC 0,5 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
10 Analogue inch dial gauges Calibration — Length
– scale int. 0,00127 mm / 0,00005” — 0 mm to 6,35 mm / 0” to 0,250” · CMC 0,4 µm / 0,000014” – scale int. 0,00254 mm / 0,00010” — 0 mm to 6,35 mm / 0” to 0,250” · CMC 0,4 µm / 0,000015” – scale int. 0,00635 mm / 0,00025” — 0 mm to 6,35 mm / 0” to 0,250” · CMC 0,5 µm / 0,000020” – scale int. 0,0127 mm / 0,0005” — 0 mm to 6,35 mm / 0” to 0,250” · CMC 0,8 µm / 0,000031” – scale int. 0,0254 mm / 0,001” — 0 mm to 6,35 mm / 0” to 0,250” · CMC 1,5 µm / 0,000060”
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
11 Analogue inch dial gauges Calibration — Length
– scale int. 0,00254 mm / 0,0001” — 0 mm to 25,4 mm / 0” to 1,000” · CMC 0,8 µm / 0,000030” – scale int. 0,0254 mm / 0,001” — 0 mm to 25,4 mm / 0” to 1,000” · CMC 1,7 µm / 0,000065” – scale int. 0,254 mm / 0,01” — 0 mm to 25,4 mm / 0” to 1,000” · CMC 14,7 µm / 0,00058”
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
12 Analogue inch dial gauges
– scale int. 0,0254 mm / 0,001”
– scale int. 0,127 mm / 0,005”
Calibration — Length
0 mm to 50,8 mm / 0” to 2,000” · CMC 2,0 µm / 0,00008” 0 mm to 76,2 mm / 0” to 3,000” · CMC 2,5 µm / 0,00010” 0 mm to 101,6 mm / 0” to 4,000” · CMC 3,0 µm / 0,00012”
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
13 Analogue inch lever dial gauges
– scale int. 0,00254 mm/ 0,0001”
– scale int. 0,00127 mm / 0,00005”
– scale int. 0,0127 mm / 0,0005”
Calibration — Length
-0,030” to 0,030” · CMC 0,3 µm / 0,000013” -0,030” to 0,030” · CMC 0,8 µm / 0,000030”
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
14 Digital dial gauges
– resolution 0,0005 mm
– resolution 0,0002 mm
Calibration — Length
0 mm to 3 mm · CMC 0,5 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
15 Digital dial gauges
– resolution 0,0005 mm
Calibration — Length
0 mm do 12,7 mm · CMC 0,8 µm 0 mm do 25,4 mm · CMC 1,1 µm 0 mm to 50,8 mm · CMC 2,0 µm 0 mm do 100 mm · CMC 3,8 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
16 Digital dial gauges
– resolution 0,001 mm
Calibration — Length
0 mm do 12,7 mm · CMC 2,8 µm 0 mm do 25,4 mm · CMC 2,9 µm 0 mm to 50,8 mm · CMC 3,4 µm
Length
Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Internal procedure IW/KUM/05/01
17 Digital dial gauges
– resolution 0,002 mm
– resolution 0,001 mm
Calibration — Length
0 mm do 12,7 mm · CMC 1,0 µm 0 mm do 25,4 mm · CMC 1,3 µm 0 mm to 50,8 mm · CMC 2,1 µm 0 mm do 100 mm · CMC 3,9 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
18 Digital dial gauges
– resolution 0,005 mm
Calibration — Length
0 mm do 12,7 mm · CMC 3,1 µm 0 mm do 25,4 mm · CMC 3,2 µm 0 mm to 50,8 mm · CMC 3,6 µm
Length
Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Internal procedure IW/KUM/05/01
19 Digital dial gauges
– resolution 0,005 mm
Calibration — Length
0 mm do 12,7 mm · CMC 1,8 µm 0 mm do 25,4 mm · CMC 2,0 µm 0 mm to 50,8 mm · CMC 2,5 µm 0 mm do 100 mm · CMC 4,1 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
20 Digital dial gauges
– resolution 0,01 mm
Calibration — Length
0 mm do 12,7 mm · CMC 3,6 µm 0 mm do 25,4 mm · CMC 3,7 µm 0 mm to 50,8 mm · CMC 4,1 µm
Length
Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Internal procedure IW/KUM/05/01
21 Digital dial gauges
– resolution 0,01 mm
Calibration — Length
0 mm do 12,7 mm · CMC 2,5 µm 0 mm do 25,4 mm · CMC 2,7 µm 0 mm to 50,8 mm · CMC 3,1 µm 0 mm do 100 mm · CMC 4,5 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
22 Digital dial gauges
– resolution 0,02 mm
Calibration — Length
0 mm do 12,7 mm · CMC 3,3 µm 0 mm do 25,4 mm · CMC 3,4 µm 0 mm to 50,8 mm · CMC 3,8 µm 0 mm do 100 mm · CMC 5,0 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
23 Digital lever dial gauges Calibration — Length
– resolution 0,01 mm — 0 mm to 1 mm · CMC 3,3 µm – resolution 0,001 mm — 0 mm to 1 mm · CMC 0,9 µm
Length
Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Internal procedure IW/KUM/18/01
24 Digital lever dial gauges Calibration — Length
– resolution 0,01 mm — 0 mm to 1 mm · CMC 3,4 µm – resolution 0,005 mm — 0 mm to 1 mm · CMC 2,9 µm – resolution 0,001 mm — 0 mm to 1 mm · CMC 2,5 µm
Length
Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Internal procedure IW/KUM/05/01
25 Optical probes Calibration — Length
– MOP 02/20 — -20 µm to 20 µm · CMC 0,12 µm – MOP 1/100 — -100 µm to 100 µm · CMC 0,13 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P) Internal procedure IW/KUM/12/01
26 Abbe vertical length measuring machines Calibration — Length
– length measuring machine measurement error — 0 mm to 100 mm · CMC Q[0,11; 3,4∙L] µm – reading microscope measurement error — 0 mm to 100 mm · CMC 0,12 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P) Internal procedure IW/KUM/12/02
27 Abbe horizontal length measuring machines Calibration — Length
– reading microscope measurements — 0 mm to 3 mm · CMC 0,1 µm – external measurements — 0 mm to 100 mm · CMC 0,5 µm – internal measurements — 0 mm to 100 mm · CMC 1,0 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P) Internal procedure IW/KUM/12/03
28 Horizontal length measuring machines (1-D machines) Calibration — Length
– measurements with the quill — 0 mm to 100 mm · CMC Q[0,10; 1,27∙L] µm – measurements with the length measuring machine — 100 mm to 500 mm · CMC Q[0,40; 2,50∙L] µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P) Internal procedure IW/KUM/12/05
29 Reference foils Calibration — Length
0 µm to 8000 µm · CMC Q[1,4; 1,2∙L] µm
Length
Internal procedure; Direct method using a thickness gauge; At permanent location (S) Internal procedure IW/KUM/07/06
30 Dial depth gauges Calibration — Length
– scale int. (0,001; 0,002; 0,005) mm — 0 mm to 5 mm · CMC 0,3 µm – scale int. 0,01 mm — 0 mm to 10 mm · CMC 0,7 µm – scale int. 0,01 mm — 0 mm to 30 mm · CMC 0,8 µm – scale int. 0,01 mm — 0 mm to 50 mm · CMC 1,0 µm – scale int. 0,1 mm — 0 mm to 50 mm · CMC 6 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/14/02
31 Dial depth gauges Calibration — Length
– resolution (0,001; 0,005; 0,01)mm — 0 mm to 10 mm · CMC 0,7 µm – resolution (0,001; 0,005; 0,01)mm — 0 mm to 30 mm · CMC 0,8 µm – resolution (0,001; 0,005; 0,01)mm — 0 mm to 50 mm · CMC 1,0 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/14/02
32 Micrometer depth gauges Calibration — Length
0 mm to 50 mm · CMC 0,8 µm 50 mm do 100 mm · CMC 1,3 µm 100 mm do 150 mm · CMC 1,9 µm 150 mm do 200 mm · CMC 2,6 µm 200 mm do 250 mm · CMC 3,3 µm 250 mm do 300 mm · CMC 3,9 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/02/02
33 Vernier depth gauges Calibration — Length
0 mm do 150 mm · CMC 8 µm 0 mm do 300 mm · CMC 11 µm 0 mm do 500 mm · CMC 16 µm 0 mm to 600 mm · CMC 18 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/01/01
34 Ultrasonic thickness gauges Calibration — Length
- resolution 0,001 mm — 0,5 mm to 50 mm · CMC 4 µm - resolution 0,001 mm — 50 mm to 100 mm · CMC 5 µm - resolution 0,001 mm — 100 mm to 125 mm · CMC 7 µm - resolution 0,01 mm — 0,5 mm to 50 mm · CMC 7 µm - resolution 0,01 mm — 50 mm to 100 mm · CMC 9 µm - resolution 0,01 mm — 100 mm to 125 mm · CMC 10 µm - resolution 0,1 mm — 0,5 mm to 125 mm · CMC 64 µm
Length
Internal procedure; Direct method using step standards for ultrasonic thickness gauges; At permanent location (S) Internal procedure IW/KUM/24/02
35 Micrometer heads Calibration — Length
0 mm do 15 mm · CMC 0,7 µm 0 mm to 25 mm · CMC 0,8 µm 0 mm to 50 mm · CMC 1,0 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/02/02
36 Dial thickness gauges Calibration — Length
– scale int. (0,001; 0,002; 0,005) mm — 0 mm to 5 mm · CMC 0,3 µm – scale int. 0,01 mm — 0 mm to 10 mm · CMC 0,7 µm – scale int. 0,01 mm — 0 mm to 30 mm · CMC 0,8 µm – scale int. 0,01 mm — 0 mm to 50 mm · CMC 1,0 µm – scale int. 0,1 mm — 0 mm to 50 mm · CMC 6 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/14/02
37 Dial thickness gauges Calibration — Length
– resolution (0,001; 0,005; 0,01)mm — 0 mm to 10 mm · CMC 0,7 µm – resolution (0,001; 0,005; 0,01)mm — 0 mm to 30 mm · CMC 0,8 µm – resolution (0,001; 0,005; 0,01)mm — 0 mm to 50 mm · CMC 1,0 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/14/02
38 External measuring calipers
Internal measuring calipers
Calibration — Length
External measuring calipers — 0 mm to 10 mm · CMC 0,5 µm External measuring calipers — 0 mm to 20 mm · CMC 0,7 µm External measuring calipers — 0 mm to 40 mm · CMC 1,2 µm External measuring calipers — 0 mm to 60 mm · CMC 1,7 µm External measuring calipers — 0 mm to 100 mm · CMC 2,8 µm Internal measuring calipers — 2,5 mm to 12,5 mm · CMC 0,6 µm Internal measuring calipers — 10 mm to 22 mm · CMC 0,8 µm Internal measuring calipers — 10 mm to 35 mm · CMC 1,1 µm Internal measuring calipers — 30 mm to 55 mm · CMC 1,6 µm Internal measuring calipers — 40 mm to 90 mm · CMC 2,5 µm Internal measuring calipers — 70 mm to 120 mm · CMC 3,3 µm Internal measuring calipers — 90 mm to 140 mm · CMC 3,9 µm Internal measuring calipers — 130 mm to 180 mm · CMC 4,9 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/14/03
39 Coating thickness meters Calibration — Length
0 µm to 200 µm · CMC 1,5 µm 200 µm to 500 µm · CMC 1,7 µm 500 µm to 1000 µm · CMC 2,0 µm 1000 µm to 1500 µm · CMC 2,4 µm 1500 µm to 2000 µm · CMC 2,9 µm
Length
Internal procedure; Direct method using reference foils; At permanent location (S) Internal procedure IW/KUM/24/01
40 Laser scan micrometers Calibration — Length
0,1 mm to 25 mm · CMC 0,32 µm
Length
Internal procedure; Direct method using measuring rollers; At permanent location (S) Internal procedure IW/KUM/25/01
41 Internal micrometers Calibration — Length
5 mm do 30 mm · CMC 1,0 µm 30 mm do 55 mm · CMC 1,2 µm 50 mm to 75 mm · CMC 1,5 µm 75 mm to 100 mm · CMC 1,8 µm 100 mm to 125 mm · CMC 2,0 µm 125 mm to 150 mm · CMC 2,5 µm 150 mm to 175 mm · CMC 2,8 µm 175 mm to 200 mm · CMC 3,2 µm 200 mm do 225 mm · CMC 3,5 µm 225 mm do 250 mm · CMC 3,8 µm 250 mm do 275 mm · CMC 4,2 µm 275 mm do 300 mm · CMC 4,5 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/02/01
42 Micrometers with built-in dial indicator Calibration — Length
– indicator unit — -140 µm to 140 µm · CMC 0,3 µm – micrometer unit — 0 mm to 25 mm · CMC 0,8 µm – micrometer unit — 25 mm to 50 mm · CMC 1,0 µm – micrometer unit — 50 mm to 75 mm · CMC 1,3 µm – micrometer unit — 75 mm to 100 mm · CMC 1,6 µm – micrometer unit — 100 mm to 125 mm · CMC 1,9 µm – micrometer unit — 125 mm to 150 mm · CMC 2,3 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/02/03
43 External micrometers Calibration — Length
0 mm to 25 mm · CMC 0,9 µm 25 mm to 50 mm · CMC 1,1 µm 50 mm to 75 mm · CMC 1,3 µm 75 mm to 100 mm · CMC 1,7 µm 100 mm to 125 mm · CMC 2,0 µm 125 mm to 150 mm · CMC 2,4 µm 150 mm to 175 mm · CMC 2,7 µm 175 mm to 200 mm · CMC 3,1 µm 200 mm do 225 mm · CMC 3,4 µm 225 mm do 250 mm · CMC 3,7 µm 250 mm do 275 mm · CMC 4,0 µm 275 mm do 300 mm · CMC 4,4 µm 300 mm do 400 mm · CMC 4,7 µm 400 mm do 500 mm · CMC 6,1 µm 500 mm do 600 mm · CMC 7,5 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/02/01
44 Digital external micrometers
– resolution 0,0001 mm
Calibration — Length
0 mm to 25 mm · CMC 0,6 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/02/01
45 Setting rings: Calibration — Length
– with the head — 3 mm to 50 mm · CMC 0,7 µm – with the head — 50 mm to 90 mm · CMC 0,8 µm – with the bows — 12 mm to 50 mm · CMC 0,6 µm – with the bows — 50 mm to 100 mm · CMC 0,7 µm – with the bows — 100 mm to 150 mm · CMC 1,0 µm – with the bows — 150 mm to 200 mm · CMC 1,4 µm – with the bows — 200 mm to 250 mm · CMC 1,8 µm – with the bows — 250 mm to 300 mm · CMC 2,3 µm
Length
Internal procedure; Direct method using a MAHR ULM 520 S-E length measuring machine; At permanent location (S) Internal procedure IW/KUM/22/01
46 Plane-parallel optical flats Calibration — Length
– length deviation — 12 mm · CMC 0,5 µm – length deviation — 15 mm · CMC 0,5 µm – length deviation — 27 mm · CMC 0,7 µm – length deviation — 40 mm · CMC 0,9 µm – length deviation — 52 mm · CMC 1,1 µm – length deviation — 65 mm · CMC 1,3 µm – length deviation — 77 mm · CMC 1,5 µm
Length
Internal procedure; Comparative method using gauge blocks and a MOP 02/20 optical probe; At permanent location (S) Internal procedure IW/KUM/08/01
47 Gauge blocks (classes 0, 1, 2) Calibration — Length
0,5 mm to 100 mm · CMC Q[0,06; 1,05∙L] µm
Length
Internal procedure; Comparative method using a TESA two-probe comparator; At permanent location (S) Internal procedure IW/KUM/16/01 based on PN-EN ISO 3650:2000
48 Gauge blocks (classes 0, 1, 2) Calibration — Length
0,5 mm to 100 mm · CMC Q[0,06; 1,05∙L] µm
Length
Internal procedure; Comparative method using a MAHR two-probe comparator; At permanent location (S) Internal procedure IW/KUM/16/02 based on PN-EN ISO 3650:2000
49 Gauge blocks (classes 0, 1, 2) Calibration — Length
125 mm to 175 mm · CMC Q[0,07; 1,00∙L] µm
Length
Internal procedure; Comparative method using a MAHR two-probe comparator; At permanent location (S) Internal procedure IW/KUM/16/02 based on PN-EN ISO 3650:2000
50 Gauge blocks (classes 0, 1, 2) Calibration — Length
150 mm to 500 mm · CMC Q[0,14; 1,03∙L] µm
Length
Internal procedure; Comparative method using a MAHR ULM 520 S-E horizontal length measuring machine; At permanent location (S) Internal procedure IW/KUM/22/07
51 Measuring tapes Calibration — Length
0 m to 5 m · CMC Q[0,11; 0,028∙L] mm 5 m do 10 m · CMC Q[0,16; 0,028∙(L-5)] mm 10 m do 15 m · CMC Q[0,20; 0,028∙(L-10)] mm 15 m do 20 m · CMC Q[0,23; 0,028∙(L-15)] mm 20 m do 25 m · CMC Q[0,26; 0,028∙(L-20)] mm
Length
Internal procedure; Comparative method using a POLMIAR rigid rule; At permanent location (S) Internal procedure IW/KUM/13/01
52 Rigid rules
Semi-rigid rules
Calibration — Length
0 m do 3 m · CMC Q[0,11; 0,028∙L] mm 0 m to 5 m · CMC Q[0,11; 0,028∙L] mm
Length
Internal procedure; Comparative method using a POLMIAR rigid or semi-rigid rule; At permanent location (S) Internal procedure IW/KUM/13/02
53 Rigid rules
Semi-rigid rules
Calibration — Length
0 mm to 300 mm · CMC Q[19; 0,04∙L] µm
Length
Internal procedure; Direct method using an ISD-V300A microscope; At permanent location (S) Internal procedure IW/KUM/23/01
54 Special vernier instruments
Digital vernier weld gauges
Calibration — Length
– welds on a plane — 0 mm to 30 mm · CMC 6 µm – corner welds — 0 mm to 30 mm · CMC 10 µm
Length
Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S) Internal procedure IW/KUM/01/02
55 Special vernier instruments
Analogue vernier weld gauges
Calibration — Length
– welds on a plane — 0 mm to 30 mm · CMC 0,06 mm – corner welds — 0 mm to 30 mm · CMC 0,06 mm
Length
Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S) Internal procedure IW/KUM/01/02
56 Weld gauges Calibration — Length
– butt weld height — 0 mm to 15 mm · CMC 0,06 mm – fillet weld height — 0 mm to 20 mm · CMC 0,06 mm – fillet weld throat thickness — 0 mm to 15 mm · CMC 0,06 mm – butt weld width — 0 mm to 60 mm · CMC 0,21 mm – undercut depth — 0 mm to 6 mm · CMC 0,065 mm
Length
Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S) Internal procedure IW/KUM/01/02
57 Special vernier instruments Calibration — Length
Vernier chamfer gauges — 0 mm to 10 mm · CMC 20 µm Taper vernier gap gauges — 0,2 mm to 40 mm · CMC 13 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/01/04
58 Cylindrical thread ring gauges Calibration — Length
pitch diameter D₂ — 2,6 mm to 90 mm · CMC 3,1 µm pitch diameter D₂ — 90 mm to 125 mm · CMC 3,2 µm
Length
Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Internal procedure IW/KUM/22/02
59 Cylindrical thread plug gauges Calibration — Length
pitch diameter d₂ — 1 mm to 100 mm · CMC 3,0 µm pitch diameter d₂ — 100 mm to 200 mm · CMC 3,1 µm
Length
Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Internal procedure IW/KUM/22/03
60 Taper thread ring gauges Calibration — Length
pitch diameter — 4 mm to 100 mm · CMC 5,0 µm
Length
Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Internal procedure IW/KUM/22/05
61 Taper thread plug gauges Calibration — Length
pitch diameter — 4 mm to 100 mm · CMC 5,0 µm
Length
Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Internal procedure IW/KUM/22/06
62 Plain ring gauges: Calibration — Length
– with the head — 3 mm to 50 mm · CMC 0,7 µm – with the head — 50 mm to 90 mm · CMC 0,8 µm – with the bows — 12 mm to 50 mm · CMC 0,6 µm – with the bows — 50 mm to 100 mm · CMC 0,7 µm – with the bows — 100 mm to 150 mm · CMC 1,0 µm – with the bows — 150 mm to 200 mm · CMC 1,4 µm – with the bows — 200 mm to 250 mm · CMC 1,8 µm – with the bows — 250 mm to 300 mm · CMC 2,3 µm
Length
Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Internal procedure IW/KUM/22/01
63 Taper hole gauges Calibration — Length
0,1 mm to 5 mm · CMC 9 µm 1 mm to 60 mm · CMC 17 µm
Length
Internal procedure; Direct method using an ISD-V300A microscope; At permanent location (S) Internal procedure IW/KUM/23/02
64 Plug gauges Calibration — Length
1 mm to 50 mm · CMC 0,5 µm 50 mm to 100 mm · CMC 0,9 µm
Length
Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S) Internal procedure IW/KUM/07/02
65 Plug gauges Calibration — Length
1 mm to 50 mm · CMC 0,4 µm 50 mm to 100 mm · CMC 0,8 µm
Length
Internal procedure; Direct method using a ULM 520 S-E horizontal length measuring machine; At permanent location (S) Internal procedure IW/KUM/07/02
66 Vernier calipers Calibration — Length
0 mm do 150 mm · CMC 8 µm 0 mm do 300 mm · CMC 11 µm 0 mm do 500 mm · CMC 16 µm 0 mm to 600 mm · CMC 18 µm 0 mm do 800 mm · CMC 23 µm 0 mm to 1000 mm · CMC 29 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/01/01
67 Feeler gauges Calibration — Length
– leaf — 0,02 mm to 3,0 mm · CMC 0,3 µm
Length
Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S) Internal procedure IW/KUM/07/01
68 Feeler gauges Calibration — Length
– leaf — 0,02 mm to 3,0 mm · CMC 0,8 µm
Length
Internal procedure; Direct method using a digital micrometer with 0,0001 mm resolution; At permanent location (S) Internal procedure IW/KUM/07/01
69 Feeler gauges Calibration — Length
– wide wedge — 0,5 mm to 27 mm · CMC 12 µm
Length
Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S) Internal procedure IW/KUM/07/01
70 Feeler gauges Calibration — Length
– wide wedge — 0,5 mm to 27 mm · CMC 14 µm
Length
Internal procedure; Direct method using a digital dial gauge with 0,0005 mm resolution; At permanent location (S) Internal procedure IW/KUM/07/01
71 Feeler gauges Calibration — Length
– wedge – flat wedge — 0,5 mm to 45 mm · CMC 8 µm
Length
Internal procedure; Direct method using a digital measuring microscope; At permanent location (S) Internal procedure IW/KUM/07/01
72 Two-point dial bore gauges
– scale interval 0,01 mm
– resolution 0,001 mm
Calibration — Length
3,5 mm to 35 mm · CMC 2,1 µm 35 mm to 60 mm · CMC 2,1 µm 50 mm to 150 mm · CMC 2,2 µm 150 mm to 250 mm · CMC 3,4 µm 250 mm to 400 mm · CMC 5,1 µm 400 mm to 600 mm · CMC 7,8 µm 600 mm to 800 mm · CMC 11,5 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/14/01
73 Two-point dial bore gauges
– scale interval 0,001 mm
– scale interval 0,0005 mm
Calibration — Length
3,5 mm to 35 mm · CMC 0,8 µm 35 mm to 60 mm · CMC 0,9 µm 50 mm to 150 mm · CMC 1,1 µm 150 mm to 250 mm · CMC 2,9 µm 250 mm to 400 mm · CMC 4,7 µm 400 mm to 600 mm · CMC 7,5 µm 600 mm to 800 mm · CMC 11,3 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/14/01
74 Two-point dial bore gauges
– resolution 0,01 mm
Calibration — Length
3,5 mm to 35 mm · CMC 8,7 µm 35 mm to 60 mm · CMC 8,7 µm 50 mm to 150 mm · CMC 8,7 µm 150 mm to 250 mm · CMC 9,0 µm 250 mm to 400 mm · CMC 9,8 µm 400 mm to 600 mm · CMC 11,4 µm 600 mm to 800 mm · CMC 14,3 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/14/01
75 Two-point dial bore gauges
– resolution 0,0005 mm
Calibration — Length
3,5 mm to 18 mm · CMC 1,2 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/14/01
76 Two-point micrometer bore gauges Calibration — Length
30 mm · CMC 0,8 µm 35 mm · CMC 0,9 µm 50 mm · CMC 1,0 µm 63 mm · CMC 1,2 µm 75 mm · CMC 1,3 µm 88 mm · CMC 1,5 µm 100 mm · CMC 1,6 µm 125 mm · CMC 1,9 µm 150 mm · CMC 2,3 µm 175 mm · CMC 2,6 µm 200 mm · CMC 2,9 µm 225 mm · CMC 3,3 µm 250 mm · CMC 3,6 µm 275 mm · CMC 3,9 µm 300 mm · CMC 4,3 µm 325 mm · CMC 4,6 µm 350 mm · CMC 4,9 µm 375 mm · CMC 5,3 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/02/04
77 Three-point micrometer bore gauges
Three-point dial bore gauges
Calibration — Length
3 mm do 100 mm · CMC 1,9 µm 100 mm do 175 mm · CMC 2,9 µm 175 mm to 200 mm · CMC 3,0 µm 200 mm do 250 mm · CMC 4,3 µm 250 mm do 300 mm · CMC 4,8 µm
Length
Internal procedure; Direct method using setting rings; At permanent location (S) Internal procedure IW/KUM/02/05
78 Transameters Calibration — Length
– transameter indicator range — -140 µm to 140 µm · CMC 0,3 µm – transameter range — 0 mm to 150 mm · CMC 0,3 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/02/03
79 Measuring rollers Calibration — Length
– for threads — 0,17 mm to 6,35 mm · CMC 0,40 µm – for holes — 0,05 mm to 10,0 mm · CMC 0,36 µm – for holes — 10,0 mm to 20,0 mm · CMC 0,37 µm – for gears — 1,7 mm to 17 mm · CMC 0,37 µm
Length
Internal procedure; Comparative method using gauge blocks and a CARL ZEISS JENA MOP 02/20 probe; At permanent location (S) Internal procedure IW/KUM/09/01
80 Measuring rollers Calibration — Length
0,05 mm to 25 mm · CMC 0,27 µm
Length
Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S) Internal procedure IW/KUM/09/02
81 Measuring rollers Calibration — Length
0,05 mm to 25 mm · CMC 0,24 µm
Length
Internal procedure; Direct method using a ULM 520 S-E horizontal length measuring machine; At permanent location (S) Internal procedure IW/KUM/09/02
82 Measuring rollers Calibration — Length
0,1 mm to 25 mm · CMC 0,51 µm
Length
Internal procedure; Direct method using a laser scan micrometer; At permanent location (S) Internal procedure IW/KUM/09/02
83 Line standards Calibration — Length
0 mm to 300 mm · CMC Q[4,5; 0,0066∙L] µm
Length
Internal procedure; Direct method using an ISD-V300A microscope; At permanent location (S) Internal procedure IW/KUM/23/01
84 Line standards of measuring magnifiers Calibration — Length
0 mm do 30 mm · CMC 3,2 µm 0 mm to 50 mm · CMC 4,0 µm
Length
Internal procedure; Indirect method using a Mitutoyo measuring microscope; At permanent location (S) Internal procedure IW/KUM/10/04
85 Circular arc standards (radius gauges) Calibration — Length
1 mm to 7 mm · CMC 4 µm 7,5 mm to 15 mm · CMC 15 µm 15,5 mm to 25 mm · CMC 21 µm
Length
Internal procedure; Indirect method using a Mitutoyo measuring microscope; At permanent location (S) Internal procedure IW/KUM/10/01
86 Circular arc standards (radius gauges) Calibration — Length
0,1 mm do 7 mm · CMC 3 µm 7 mm do 15 mm · CMC 4 µm 15 mm do 25 mm · CMC 13 µm 25 mm to 50 mm · CMC 20 µm 50 mm do 100 mm · CMC 33 µm
Length
Internal procedure; Direct method using an ISD-V300A measuring microscope; At permanent location (S) Internal procedure IW/KUM/23/03
87 Setting standards for external dimensions Calibration — Length
25 mm to 50 mm · CMC 0,5 µm 50 mm do 100 mm · CMC 0,6 µm 100 mm do 150 mm · CMC 0,8 µm
Length
Internal procedure; Comparative method using a transameter; At permanent location (S) Internal instruction IW/KUM/02/06
88 Setting standards for external dimensions Calibration — Length
25 mm to 100 mm · CMC 0,4 µm 100 mm to 200 mm · CMC 1,0 µm 200 mm to 300 mm · CMC 1,4 µm 300 mm to 400 mm · CMC 1,8 µm 400 mm to 500 mm · CMC 2,2 µm
Length
Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Internal procedure IW/KUM/22/04
89 Step standards for ultrasonic thickness gauges Calibration — Length
– steel — 0,5 mm to 50 mm · CMC 3 µm – steel — 50 mm to 100 mm · CMC 5 µm – steel — 100 mm to 125 mm · CMC 6 µm – aluminium — 0,5 mm to 50 mm · CMC 4 µm – aluminium — 50 mm to 100 mm · CMC 6 µm – aluminium — 100 mm to 125 mm · CMC 7 µm
Length
Internal procedure; Direct method using digital external micrometers; At permanent location (S) Internal procedure IW/KUM/26/01
90 Thread profile standards Calibration — Length
– metric — 0,25 mm to 6 mm · CMC 4 µm – inch — 4 to 62 threads per inch · CMC 4 µm
Length
Internal procedure; Indirect method using a Mitutoyo measuring microscope; At permanent location (S) Internal procedure IW/KUM/10/02
91 Digital height gauges Calibration — Length
– resolution 0,01 mm — 0 mm to 1000 mm · CMC Q[5,86; 3,24∙L] µm – resolution 0,005 mm — 0 mm to 1000 mm · CMC Q[3,03; 3,24∙L] µm – resolution 0,001 mm — 0 mm to 1000 mm · CMC Q[1,11; 3,24∙L] µm – resolution 0,0005 mm — 0 mm to 1000 mm · CMC Q[1,00; 3,24∙L] µm – resolution 0,0001 mm — 0 mm to 1000 mm · CMC Q[0,95; 3,24∙L] µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P) Internal procedure IW/KUM/12/04
92 Height gauges for measuring vehicle wheel height Calibration — Length
0 mm to 1000 mm · CMC 0,5 mm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/01/03
93 Vernier height gauges Calibration — Length
0 mm do 300 mm · CMC 11 µm 0 mm to 600 mm · CMC 18 µm 0 mm do 750 mm · CMC 22 µm 0 mm to 1000 mm · CMC 29 µm
Length
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/01/01
94 Analogue universal protractors Calibration — Angle
4 x 90° · CMC 3,0'
Angle
Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Internal procedure IW/KUM/03/01
95 Digital universal protractors Calibration — Angle
0° to 360° · CMC 1,5'
Angle
Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Internal procedure IW/KUM/03/01
96 Digital protractors Calibration — Angle
0° to 360° · CMC 0,04°
Angle
Internal procedure; Direct method using an angle prism; At permanent location (S) Internal procedure IW/KUM/03/02
97 Marking-out protractors Calibration — Angle
0° to 180° · CMC 0,12°
Angle
Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Internal procedure IW/KUM/03/01
98 90° two-leg squares Calibration — Angle
longer leg length; – flatness — 40 mm to 500 mm · CMC 2 µm longer leg length; – straightness — 40 mm to 500 mm · CMC 1 µm longer leg length; – parallelism — 40 mm to 500 mm · CMC 1,4 µm longer leg length; – perpendicularity — 40 mm to 500 mm · CMC 1,1 µm
Angle
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/04/01
99 90° cylindrical squares Calibration — Angle
0 mm to 400 mm · CMC 1,0 µm
Angle
Internal procedure; Indirect method using an inductive probe; At permanent location (S) Internal procedure IW/KUM/15/01
100 Optical angle levels Calibration — Angle
– zero setting error — -120° to 120° · CMC 0,2 dz. el. – scale interval value error — -120° to 120° · CMC 4″ – measurement error over the full range — -120° to 120° · CMC 12″
Angle
Internal procedure; Direct method using an optical dividing head; At permanent location (S) Internal procedure IW/KUM/21/01
101 Angle gauge blocks with matt surfaces Calibration — Angle
0° to 30° · CMC 31″
Angle
Internal procedure; Indirect method using a microscope; At permanent location (S) Internal procedure IW/KUM/10/03
102 Builder's levels Calibration — Angle
– vial zero indication setting error — 0 m to 2 m · CMC 0,2 mm
Angle
Internal procedure; Direct method using a CARL ZEISS JENA measuring bed; At permanent location (S) Internal procedure IW/KUM/11/02
103 Digital levels Calibration — Angle
4 x 90° · CMC 0,04°
Angle
Internal procedure; Direct method using a CARL ZEISS JENA optical dividing head; At permanent location (S) Internal procedure IW/KUM/11/02
104 Coincidence levels Calibration — Angle
– measurement error over the full range — 0 mm/m to 20 mm/m · CMC 0,014 mm/m – zero indication setting error — 0 mm/m to 20 mm/m · CMC 0,002 mm/m
Angle
Internal procedure; Direct method using a CARL ZEISS JENA optical dividing head; At permanent location (S) Internal procedure IW/KUM/21/02
105 Straightedge levels Calibration — Angle
– zero indication setting error — 0 mm/m to 1 mm/m · CMC 0,2 dz. el. – scale interval value error — 0 mm/m to 1 mm/m · CMC 0,019 mm/m
Angle
Internal procedure; Direct method using a coincidence level; At permanent location (S) Internal procedure IW/KUM/11/01
106 Weld gauges Calibration — Angle
– bevel angle measurements — 80° to 160° · CMC 0,29°
Angle
Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Internal procedure IW/KUM/01/02
107 Knife-edge straightedges Calibration — Surface geometry
0 mm to 100 mm · CMC 0,7 µm 100 mm to 400 mm · CMC 2,3 µm 400 mm to 700 mm · CMC 3,9 µm
Surface geometry
Internal procedure; Direct method using gauge blocks; At permanent location (S) Internal procedure IW/KUM/17/03
108 Optical flats Calibration — Surface geometry
diameter — 0 mm to 100 mm · CMC 0,04 µm
Surface geometry
Internal procedure; Indirect method using optical flats; At permanent location (S) Internal procedure IW/KUM/08/01
109 Plane-parallel optical flats Calibration — Surface geometry
flat length; – surface flatness deviation — 12,00 mm to 80,00 mm · CMC 0,06 µm flat length; – surface parallelism deviation — 12,00 mm to 80,00 mm · CMC 0,16 µm
Surface geometry
Internal procedure; Indirect method using optical flats and a MOP 02/20 probe; At permanent location (S) Internal procedure IW/KUM/08/01
110 Surface plates Calibration — Surface geometry
longer side length — 250 mm · CMC 1,1 µm longer side length — 400 mm · CMC 1,3 µm longer side length — 630 mm · CMC 1,8 µm longer side length — 800 mm · CMC 2,0 µm longer side length — 1000 mm · CMC 2,2 µm longer side length — 1200 mm · CMC 2,5 µm longer side length — 1600 mm · CMC 2,9 µm longer side length — 2000 mm · CMC 3,2 µm longer side length — 2500 mm · CMC 3,6 µm
Surface geometry
Internal procedure; Indirect method using Talyvel 6 Taylor-Hobson differential levels; At permanent location (S) and outside of it (P) Internal procedure IW/KUM/20/01 based on PN-ISO 8512-1:1998 PN-ISO 8512-2:1999
111 Surface straightedges Calibration — Surface geometry
straightedge length — 250 mm · CMC 1,0 µm straightedge length — 500 mm · CMC 1,5 µm straightedge length — 1000 mm · CMC 2,2 µm straightedge length — 1500 mm · CMC 2,8 µm straightedge length — 2000 mm · CMC 3,2 µm straightedge length — 2500 mm · CMC 3,6 µm straightedge length — 3000 mm · CMC 4,0 µm straightedge length — 4000 mm · CMC 4,6 µm straightedge length — 5000 mm · CMC 5,2 µm
Surface geometry
Internal procedure; Indirect method using Talyvel 6 Taylor-Hobson differential levels; At permanent location (S) and outside of it (P) Internal procedure IW/KUM/20/01

Reference standards (62)

IW/KUM/01/01
IW/KUM/01/02
IW/KUM/01/03
IW/KUM/01/04
IW/KUM/02/01
IW/KUM/02/02
IW/KUM/02/03
IW/KUM/02/04
IW/KUM/02/05
IW/KUM/02/06
IW/KUM/03/01
IW/KUM/03/02
IW/KUM/04/01
IW/KUM/05/01
IW/KUM/06/01
IW/KUM/07/01
IW/KUM/07/02
IW/KUM/07/06
IW/KUM/08/01
IW/KUM/09/01
IW/KUM/09/02
IW/KUM/10/01
IW/KUM/10/02
IW/KUM/10/03
IW/KUM/10/04
IW/KUM/11/01
IW/KUM/11/02
IW/KUM/12/01
IW/KUM/12/02
IW/KUM/12/03
IW/KUM/12/04
IW/KUM/12/05
IW/KUM/13/01
IW/KUM/13/02
IW/KUM/14/01
IW/KUM/14/02
IW/KUM/14/03
IW/KUM/15/01
IW/KUM/16/01
IW/KUM/16/02
IW/KUM/17/03
IW/KUM/18/01
IW/KUM/20/01
IW/KUM/21/01
IW/KUM/21/02
IW/KUM/22/01
IW/KUM/22/02
IW/KUM/22/03
IW/KUM/22/04
IW/KUM/22/05
IW/KUM/22/06
IW/KUM/22/07
IW/KUM/23/01
IW/KUM/23/02
IW/KUM/23/03
IW/KUM/24/01
IW/KUM/24/02
IW/KUM/25/01
IW/KUM/26/01
PN-EN ISO 3650:2000
PN-ISO 8512-1:1998
PN-ISO 8512-2:1999

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20162