{"lab":{"_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","imported_at":"2026-11-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Demokratyczna 117, 93-348 Łódź","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"23.04.2020","city":"Łódź","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Niepewność pomiaru dla CMC wyrażona jest w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w postaci równania Q[a; b] oznacza pierwiastek sumy kwadratów wyrazów w nawiasach: Q[a; b] = (a² + b²)^1/2.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The CMC uncertainty is expressed in measurand units. A CMC uncertainty value expressed as the equation Q[a; b] means the root sum of squares of the terms in brackets: Q[a; b] = (a² + b²)^1/2.","cycle_from":"18.03.2024","cycle_to":"28.04.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"6.02","pl":"kąt","en":"angle","de":"Winkel","zh":"角度","cs":"úhel"},{"codes":"6.03","pl":"długość (geometria powierzchni)","en":"length (surface geometry)","de":"Länge (Oberflächengeometrie)","zh":"长度（表面几何）","cs":"délka (geometrie povrchu)"}],"has_en":true,"has_zh":true,"issue":{"no":"13","date":"10.03.2026"},"issue_date":"10.03.2026","issue_number":"13","lab_division":"Laboratorium Wzorcujące","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[19.4607407,51.7116217]},"map_coord":[51.7116217,19.4607407],"map_geo":"nominatim-street","methods_count":111,"name":"Krajowe Usługi Metrologiczne M. Koziorowski, P. Koziorowski s.c.","parse_date":"2026-11-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-15T12:00:00.000Z","pdf_files":["AP_162.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: długość, kąt, długość (geometria powierzchni). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"krajowe usługi metrologiczne m. koziorowski, p. koziorowski s.c. laboratorium wzorcujące ul. demokratyczna 117, 93-348 łódź laboratorium wzorcujące. wielkości mierzone: długość, kąt, długość (geometria powierzchni). w stałej lokalizacji (s) i/lub poza nią (p). ap 162 ap162 laboratorium wzorcujące wzorcowanie kalibracja length angle length (surface geometry) krajowe uslugi metrologiczne m. koziorowski, p. koziorowski s.c. laboratorium wzorcujace ul. demokratyczna 117, 93-348 lodz laboratorium wzorcujace. wielkosci mierzone: dlugosc, kat, dlugosc (geometria powierzchni). w stalej lokalizacji (s) i/lub poza nia (p). ap 162 ap162 laboratorium wzorcujace wzorcowanie kalibracja length angle length (surface geometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20162,podmiot.html","source_pdf_sha256":"6e85ccdc15d9ad4217516c100b768ea4131d29249dc20df724c716e0ac198e3b","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/15/3c782e7be57a01c2e7bc1b86fe8c2bd1/AP%20162.pdf","status":"active","updated_at":"2026-11-15T12:00:00.000Z","valid_from":"29-04-2016","valid_until":"28-04-2028","website":"www.kumlab.eu","lab_division_en":"Calibration Laboratory","cmc_note_de":"Die von der CMC abgedeckte Messunsicherheit ist die erweiterte Unsicherheit bei einer Überdeckungswahrscheinlichkeit von ca. 95 %. Die CMC-Messunsicherheit ist in Einheiten der Messgröße angegeben. Ein als Gleichung Q[a; b] angegebener CMC-Unsicherheitswert bedeutet die Wurzel aus der Summe der Quadrate der Terme in Klammern: Q[a; b] = (a² + b²)^1/2.","has_de":true,"lab_division_de":"Kalibrierlaboratorium","cmc_note_zh":"CMC 测量不确定度为包含概率约 95 % 的扩展不确定度。CMC 测量不确定度以被测量的单位表示。以方程 Q[a; b] 表示的 CMC 测量不确定度值为括号内各项平方和的平方根：Q[a; b] = (a² + b²)^1/2。","lab_division_zh":"校准实验室","cmc_note_cs":"Nejistota měření pro CMC je rozšířená nejistota při pravděpodobnosti pokrytí přibližně 95 %. Nejistota měření pro CMC je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření pro CMC vyjádřená rovnicí Q[a; b] znamená druhou odmocninu součtu čtverců členů v závorkách: Q[a; b] = (a² + b²)^1/2.","has_cs":true,"lab_division_cs":"Kalibrační laboratoř","pelny_cs":true},"methods":[{"_id":"886da7bbb005b2f649fa5476","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe\n– działka elementarna 0,01 mm","test_object_en":"Analogue dial gauges\n– scale interval 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"3,3 µm"}],"parameters_en":[{"name":"","range":"0 mm do 10 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm to 50 mm","cmc":"3,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a Mitutoyo micrometer head","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 2,5 µm\n0 mm do 30 mm CMC 2,9 µm\n0 mm do 50 mm CMC 3,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/05/01","norm_bases":["IW/KUM/05/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe\n– działka elementarna 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 2,5 µm\n0 mm do 30 mm CMC 2,9 µm\n0 mm do 50 mm CMC 3,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/05/01 Czujniki analogowe\n– dzialka elementarna 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 10 mm CMC 2,5 µm\n0 mm do 30 mm CMC 2,9 µm\n0 mm do 50 mm CMC 3,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem glowicy mikrometrycznej Mitutoyo; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/05/01","search_en":"Analogue dial gauges – scale interval 0,01 mm Calibration — Length Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Length Internal procedure Direct method using a Mitutoyo micrometer head At permanent location (S) Internal procedure IW/KUM/05/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/05/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 10 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm bis 50 mm","cmc":"3,3 µm"}],"reference_de":"Internes Verfahren IW/KUM/05/01","regulatory_area_de":"Länge","search_de":"Analoge Messuhren – Skalenteilungswert 0,01 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf Am festen Standort (S) Internes Verfahren IW/KUM/05/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren\n– Skalenteilungswert 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 10 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm 至 50 mm","cmc":"3,3 µm"}],"reference_zh":"内部程序 IW/KUM/05/01","regulatory_area_zh":"长度","search_zh":"模拟指示表 – 分度值 0,01 mm 校准 — 长度 内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo测微头的直接法 在固定地点 (S) 内部程序 IW/KUM/05/01","technique_zh":"内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo测微头的直接法","在固定地点 (S)"],"test_object_zh":"模拟指示表\n– 分度值 0,01 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 10 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"3,3 µm"}],"reference_cs":"Vnitřní postup IW/KUM/05/01","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry – hodnota dílku 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím mikrometrické hlavice Mitutoyo Ve stálé lokalitě (S) Vnitřní postup IW/KUM/05/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím mikrometrické hlavice Mitutoyo","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry\n– hodnota dílku 0,01 mm"},{"_id":"e240534eb44f8e898ab317db","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem\n– działka elementarna 0,01 mm","test_object_en":"Analogue lever dial gauges\n– scale interval 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 3 mm","cmc":"2,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 3 mm","cmc":"2,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a Mitutoyo micrometer head","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 3 mm CMC 2,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/05/01","norm_bases":["IW/KUM/05/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem\n– działka elementarna 0,01 mm Wzorcowanie — Długość\n0 mm do 3 mm CMC 2,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/05/01 Czujniki analogowe z uchylnym trzpieniem\n– dzialka elementarna 0,01 mm Wzorcowanie — Dlugosc\n0 mm do 3 mm CMC 2,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem glowicy mikrometrycznej Mitutoyo; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/05/01","search_en":"Analogue lever dial gauges – scale interval 0,01 mm Calibration — Length Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Length Internal procedure Direct method using a Mitutoyo micrometer head At permanent location (S) Internal procedure IW/KUM/05/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/05/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 3 mm","cmc":"2,5 µm"}],"reference_de":"Internes Verfahren IW/KUM/05/01","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte – Skalenteilungswert 0,01 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf Am festen Standort (S) Internes Verfahren IW/KUM/05/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte\n– Skalenteilungswert 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 3 mm","cmc":"2,5 µm"}],"reference_zh":"内部程序 IW/KUM/05/01","regulatory_area_zh":"长度","search_zh":"指针式杠杆千分表 – 分度值 0,01 mm 校准 — 长度 内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo测微头的直接法 在固定地点 (S) 内部程序 IW/KUM/05/01","technique_zh":"内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo测微头的直接法","在固定地点 (S)"],"test_object_zh":"指针式杠杆千分表\n– 分度值 0,01 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 3 mm","cmc":"2,5 µm"}],"reference_cs":"Vnitřní postup IW/KUM/05/01","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry – hodnota dílku 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím mikrometrické hlavice Mitutoyo Ve stálé lokalitě (S) Vnitřní postup IW/KUM/05/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím mikrometrické hlavice Mitutoyo","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry\n– hodnota dílku 0,01 mm"},{"_id":"69cda1bf35b831d5cc395591","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe\n– działka elementarna (0,002; 0,001) mm","test_object_en":"Analogue dial gauges\n– scale interval (0,002; 0,001) mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 5 mm","cmc":"1,8 µm"}],"parameters_en":[{"name":"","range":"0 mm to 5 mm","cmc":"1,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mitutoyo Typ 521-105; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a Mitutoyo Type 521-105 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mitutoyo Typ 521-105","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a Mitutoyo Type 521-105 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 5 mm CMC 1,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mitutoyo Typ 521-105; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/06/01","norm_bases":["IW/KUM/06/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe\n– działka elementarna (0,002; 0,001) mm Wzorcowanie — Długość\n0 mm do 5 mm CMC 1,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mitutoyo Typ 521-105; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/06/01 Czujniki analogowe\n– dzialka elementarna (0,002; 0,001) mm Wzorcowanie — Dlugosc\n0 mm do 5 mm CMC 1,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mitutoyo Typ 521-105; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/06/01","search_en":"Analogue dial gauges – scale interval (0,002; 0,001) mm Calibration — Length Internal procedure; Direct method using a Mitutoyo Type 521-105 instrument; At permanent location (S) Length Internal procedure Direct method using a Mitutoyo Type 521-105 instrument At permanent location (S) Internal procedure IW/KUM/06/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/06/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 5 mm","cmc":"1,8 µm"}],"reference_de":"Internes Verfahren IW/KUM/06/01","regulatory_area_de":"Länge","search_de":"Analoge Messuhren – Skalenteilungswert (0,002; 0,001) mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät Mitutoyo Typ 521-105; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät Mitutoyo Typ 521-105 Am festen Standort (S) Internes Verfahren IW/KUM/06/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät Mitutoyo Typ 521-105; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät Mitutoyo Typ 521-105","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren\n– Skalenteilungswert (0,002; 0,001) mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 5 mm","cmc":"1,8 µm"}],"reference_zh":"内部程序 IW/KUM/06/01","regulatory_area_zh":"长度","search_zh":"模拟指示表 – 分度值 (0,002; 0,001) mm 校准 — 长度 内部程序；使用Mitutoyo 521-105型仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo 521-105型仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/06/01","technique_zh":"内部程序；使用Mitutoyo 521-105型仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo 521-105型仪器的直接法","在固定地点 (S)"],"test_object_zh":"模拟指示表\n– 分度值 (0,002; 0,001) mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 5 mm","cmc":"1,8 µm"}],"reference_cs":"Vnitřní postup IW/KUM/06/01","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry – hodnota dílku (0,002; 0,001) mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mitutoyo typ 521-105; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mitutoyo typ 521-105 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/06/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mitutoyo typ 521-105; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mitutoyo typ 521-105","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry\n– hodnota dílku (0,002; 0,001) mm"},{"_id":"90448bc0128cb5b4ece09d16","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem\n– działka elementarna (0,002; 0,001) mm","test_object_en":"Analogue lever dial gauges\n– scale interval (0,002; 0,001) mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 0,6 mm","cmc":"1,8 µm"}],"parameters_en":[{"name":"","range":"0 mm to 0,6 mm","cmc":"1,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mitutoyo Typ 521-105; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a Mitutoyo Type 521-105 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu Mitutoyo Typ 521-105","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a Mitutoyo Type 521-105 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 0,6 mm CMC 1,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mitutoyo Typ 521-105; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/06/01","norm_bases":["IW/KUM/06/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem\n– działka elementarna (0,002; 0,001) mm Wzorcowanie — Długość\n0 mm do 0,6 mm CMC 1,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu Mitutoyo Typ 521-105; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/06/01 Czujniki analogowe z uchylnym trzpieniem\n– dzialka elementarna (0,002; 0,001) mm Wzorcowanie — Dlugosc\n0 mm do 0,6 mm CMC 1,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu Mitutoyo Typ 521-105; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/06/01","search_en":"Analogue lever dial gauges – scale interval (0,002; 0,001) mm Calibration — Length Internal procedure; Direct method using a Mitutoyo Type 521-105 instrument; At permanent location (S) Length Internal procedure Direct method using a Mitutoyo Type 521-105 instrument At permanent location (S) Internal procedure IW/KUM/06/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/06/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 0,6 mm","cmc":"1,8 µm"}],"reference_de":"Internes Verfahren IW/KUM/06/01","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte – Skalenteilungswert (0,002; 0,001) mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät Mitutoyo Typ 521-105; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät Mitutoyo Typ 521-105 Am festen Standort (S) Internes Verfahren IW/KUM/06/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät Mitutoyo Typ 521-105; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät Mitutoyo Typ 521-105","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte\n– Skalenteilungswert (0,002; 0,001) mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 0,6 mm","cmc":"1,8 µm"}],"reference_zh":"内部程序 IW/KUM/06/01","regulatory_area_zh":"长度","search_zh":"指针式杠杆千分表 – 分度值 (0,002; 0,001) mm 校准 — 长度 内部程序；使用Mitutoyo 521-105型仪器的直接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo 521-105型仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/06/01","technique_zh":"内部程序；使用Mitutoyo 521-105型仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo 521-105型仪器的直接法","在固定地点 (S)"],"test_object_zh":"指针式杠杆千分表\n– 分度值 (0,002; 0,001) mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 0,6 mm","cmc":"1,8 µm"}],"reference_cs":"Vnitřní postup IW/KUM/06/01","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry – hodnota dílku (0,002; 0,001) mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje Mitutoyo typ 521-105; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje Mitutoyo typ 521-105 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/06/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje Mitutoyo typ 521-105; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje Mitutoyo typ 521-105","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry\n– hodnota dílku (0,002; 0,001) mm"},{"_id":"40618a355a4514bcb9efe458","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe\n– działka elementarna 0,1 mm","test_object_en":"Analogue dial gauges\n– scale interval 0,1 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 50 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe\n– działka elementarna 0,1 mm Wzorcowanie — Długość\n0 mm do 50 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki analogowe\n– dzialka elementarna 0,1 mm Wzorcowanie — Dlugosc\n0 mm do 50 mm CMC 6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Analogue dial gauges – scale interval 0,1 mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"6 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Analoge Messuhren – Skalenteilungswert 0,1 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren\n– Skalenteilungswert 0,1 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"6 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"模拟指示表 – 分度值 0,1 mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"模拟指示表\n– 分度值 0,1 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"6 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry – hodnota dílku 0,1 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry\n– hodnota dílku 0,1 mm"},{"_id":"dce1159fe453aae587568364","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe\n– działka elementarna (0,02; 0,01) mm","test_object_en":"Analogue dial gauges\n– scale interval (0,02; 0,01) mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"1,0 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,5 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 80 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,9 µm"}],"parameters_en":[{"name":"","range":"0 mm do 10 mm","cmc":"1,0 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,5 µm"},{"name":"","range":"0 mm to 50 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 80 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 1,0 µm\n0 mm do 30 mm CMC 1,5 µm\n0 mm do 50 mm CMC 2,1 µm\n0 mm do 80 mm CMC 3,1 µm\n0 mm do 100 mm CMC 3,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe\n– działka elementarna (0,02; 0,01) mm Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 1,0 µm\n0 mm do 30 mm CMC 1,5 µm\n0 mm do 50 mm CMC 2,1 µm\n0 mm do 80 mm CMC 3,1 µm\n0 mm do 100 mm CMC 3,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki analogowe\n– dzialka elementarna (0,02; 0,01) mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 10 mm CMC 1,0 µm\n0 mm do 30 mm CMC 1,5 µm\n0 mm do 50 mm CMC 2,1 µm\n0 mm do 80 mm CMC 3,1 µm\n0 mm do 100 mm CMC 3,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Analogue dial gauges – scale interval (0,02; 0,01) mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 10 mm","cmc":"1,0 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,5 µm"},{"name":"","range":"0 mm bis 50 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 80 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,9 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Analoge Messuhren – Skalenteilungswert (0,02; 0,01) mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren\n– Skalenteilungswert (0,02; 0,01) mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 10 mm","cmc":"1,0 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,5 µm"},{"name":"","range":"0 mm 至 50 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 80 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,9 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"模拟指示表 – 分度值 (0,02; 0,01) mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"模拟指示表\n– 分度值 (0,02; 0,01) mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 10 mm","cmc":"1,0 µm"},{"name":"","range":"0 mm do 30 mm","cmc":"1,5 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 80 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,9 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry – hodnota dílku (0,02; 0,01) mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry\n– hodnota dílku (0,02; 0,01) mm"},{"_id":"ed803c8d7f5bd911d46bdcbb","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe\n– działka elementarna (0,005; 0,002; 0,001) mm","test_object_en":"Analogue dial gauges\n– scale interval (0,005; 0,002; 0,001) mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 5 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 5 mm","cmc":"0,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 5 mm CMC 0,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe\n– działka elementarna (0,005; 0,002; 0,001) mm Wzorcowanie — Długość\n0 mm do 5 mm CMC 0,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki analogowe\n– dzialka elementarna (0,005; 0,002; 0,001) mm Wzorcowanie — Dlugosc\n0 mm do 5 mm CMC 0,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Analogue dial gauges – scale interval (0,005; 0,002; 0,001) mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 5 mm","cmc":"0,5 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Analoge Messuhren – Skalenteilungswert (0,005; 0,002; 0,001) mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren\n– Skalenteilungswert (0,005; 0,002; 0,001) mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 5 mm","cmc":"0,5 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"模拟指示表 – 分度值 (0,005; 0,002; 0,001) mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"模拟指示表\n– 分度值 (0,005; 0,002; 0,001) mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 5 mm","cmc":"0,5 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry – hodnota dílku (0,005; 0,002; 0,001) mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry\n– hodnota dílku (0,005; 0,002; 0,001) mm"},{"_id":"b3c20444d70f220d219dcc25","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem\n– działka elementarna (0,02; 0,01) mm","test_object_en":"Analogue lever dial gauges\n– scale interval (0,02; 0,01) mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 3 mm","cmc":"0,9 µm"}],"parameters_en":[{"name":"","range":"0 mm to 3 mm","cmc":"0,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 3 mm CMC 0,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem\n– działka elementarna (0,02; 0,01) mm Wzorcowanie — Długość\n0 mm do 3 mm CMC 0,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki analogowe z uchylnym trzpieniem\n– dzialka elementarna (0,02; 0,01) mm Wzorcowanie — Dlugosc\n0 mm do 3 mm CMC 0,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Analogue lever dial gauges – scale interval (0,02; 0,01) mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 3 mm","cmc":"0,9 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte – Skalenteilungswert (0,02; 0,01) mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte\n– Skalenteilungswert (0,02; 0,01) mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 3 mm","cmc":"0,9 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"指针式杠杆千分表 – 分度值 (0,02; 0,01) mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"指针式杠杆千分表\n– 分度值 (0,02; 0,01) mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 3 mm","cmc":"0,9 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry – hodnota dílku (0,02; 0,01) mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry\n– hodnota dílku (0,02; 0,01) mm"},{"_id":"a1676b5fb5b5a0089c1f3feb","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem\n– działka elementarna (0,005; 0,002; 0,001) mm","test_object_en":"Analogue lever dial gauges\n– scale interval (0,005; 0,002; 0,001) mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 0,6 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 0,6 mm CMC 0,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem\n– działka elementarna (0,005; 0,002; 0,001) mm Wzorcowanie — Długość\n0 mm do 0,6 mm CMC 0,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki analogowe z uchylnym trzpieniem\n– dzialka elementarna (0,005; 0,002; 0,001) mm Wzorcowanie — Dlugosc\n0 mm do 0,6 mm CMC 0,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Analogue lever dial gauges – scale interval (0,005; 0,002; 0,001) mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,5 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte – Skalenteilungswert (0,005; 0,002; 0,001) mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte\n– Skalenteilungswert (0,005; 0,002; 0,001) mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,5 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"指针式杠杆千分表 – 分度值 (0,005; 0,002; 0,001) mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"指针式杠杆千分表\n– 分度值 (0,005; 0,002; 0,001) mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,5 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry – hodnota dílku (0,005; 0,002; 0,001) mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry\n– hodnota dílku (0,005; 0,002; 0,001) mm"},{"_id":"7c06d98bdf9447e123ce52e4","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe calowe","test_object_en":"Analogue inch dial gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– dz. element. 0,00127 mm / 0,00005”","range":"0 mm do 6,35 mm / 0” do 0,250”","cmc":"0,4 µm / 0,000014”"},{"name":"– dz. element. 0,00254 mm / 0,00010”","range":"0 mm do 6,35 mm / 0” do 0,250”","cmc":"0,4 µm / 0,000015”"},{"name":"– dz. element. 0,00635 mm / 0,00025”","range":"0 mm do 6,35 mm / 0” do 0,250”","cmc":"0,5 µm / 0,000020”"},{"name":"– dz. element. 0,0127 mm / 0,0005”","range":"0 mm do 6,35 mm / 0” do 0,250”","cmc":"0,8 µm / 0,000031”"},{"name":"– dz. element. 0,0254 mm / 0,001”","range":"0 mm do 6,35 mm / 0” do 0,250”","cmc":"1,5 µm / 0,000060”"}],"parameters_en":[{"name":"– scale int. 0,00127 mm / 0,00005”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,4 µm / 0,000014”"},{"name":"– scale int. 0,00254 mm / 0,00010”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,4 µm / 0,000015”"},{"name":"– scale int. 0,00635 mm / 0,00025”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,5 µm / 0,000020”"},{"name":"– scale int. 0,0127 mm / 0,0005”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,8 µm / 0,000031”"},{"name":"– scale int. 0,0254 mm / 0,001”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"1,5 µm / 0,000060”"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– dz. element. 0,00127 mm / 0,00005” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,4 µm / 0,000014”\n– dz. element. 0,00254 mm / 0,00010” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,4 µm / 0,000015”\n– dz. element. 0,00635 mm / 0,00025” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,5 µm / 0,000020”\n– dz. element. 0,0127 mm / 0,0005” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,8 µm / 0,000031”\n– dz. element. 0,0254 mm / 0,001” 0 mm do 6,35 mm / 0” do 0,250” CMC 1,5 µm / 0,000060”\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe calowe Wzorcowanie — Długość\nZakres:\n– dz. element. 0,00127 mm / 0,00005” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,4 µm / 0,000014”\n– dz. element. 0,00254 mm / 0,00010” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,4 µm / 0,000015”\n– dz. element. 0,00635 mm / 0,00025” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,5 µm / 0,000020”\n– dz. element. 0,0127 mm / 0,0005” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,8 µm / 0,000031”\n– dz. element. 0,0254 mm / 0,001” 0 mm do 6,35 mm / 0” do 0,250” CMC 1,5 µm / 0,000060”\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki analogowe calowe Wzorcowanie — Dlugosc\nZakres:\n– dz. element. 0,00127 mm / 0,00005” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,4 µm / 0,000014”\n– dz. element. 0,00254 mm / 0,00010” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,4 µm / 0,000015”\n– dz. element. 0,00635 mm / 0,00025” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,5 µm / 0,000020”\n– dz. element. 0,0127 mm / 0,0005” 0 mm do 6,35 mm / 0” do 0,250” CMC 0,8 µm / 0,000031”\n– dz. element. 0,0254 mm / 0,001” 0 mm do 6,35 mm / 0” do 0,250” CMC 1,5 µm / 0,000060”\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Analogue inch dial gauges Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) – scale int. 0,00127 mm / 0,00005” – scale int. 0,00254 mm / 0,00010” – scale int. 0,00635 mm / 0,00025” – scale int. 0,0127 mm / 0,0005” – scale int. 0,0254 mm / 0,001” Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Skalenteilungswert 0,00127 mm / 0,00005”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,4 µm / 0,000014”"},{"name":"– Skalenteilungswert 0,00254 mm / 0,00010”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,4 µm / 0,000015”"},{"name":"– Skalenteilungswert 0,00635 mm / 0,00025”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,5 µm / 0,000020”"},{"name":"– Skalenteilungswert 0,0127 mm / 0,0005”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,8 µm / 0,000031”"},{"name":"– Skalenteilungswert 0,0254 mm / 0,001”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"1,5 µm / 0,000060”"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Analoge Zoll-Messuhren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) – Skalenteilungswert 0,00127 mm / 0,00005” – Skalenteilungswert 0,00254 mm / 0,00010” – Skalenteilungswert 0,00635 mm / 0,00025” – Skalenteilungswert 0,0127 mm / 0,0005” – Skalenteilungswert 0,0254 mm / 0,001” Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Analoge Zoll-Messuhren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 分度值 0,00127 mm / 0,00005”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,4 µm / 0,000014”"},{"name":"– 分度值 0,00254 mm / 0,00010”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,4 µm / 0,000015”"},{"name":"– 分度值 0,00635 mm / 0,00025”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,5 µm / 0,000020”"},{"name":"– 分度值 0,0127 mm / 0,0005”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,8 µm / 0,000031”"},{"name":"– 分度值 0,0254 mm / 0,001”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"1,5 µm / 0,000060”"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"英制模拟指示表 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) – 分度值 0,00127 mm / 0,00005” – 分度值 0,00254 mm / 0,00010” – 分度值 0,00635 mm / 0,00025” – 分度值 0,0127 mm / 0,0005” – 分度值 0,0254 mm / 0,001” 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"英制模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– hodnota dílku 0,00127 mm / 0,00005”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,4 µm / 0,000014”"},{"name":"– hodnota dílku 0,00254 mm / 0,00010”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,4 µm / 0,000015”"},{"name":"– hodnota dílku 0,00635 mm / 0,00025”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,5 µm / 0,000020”"},{"name":"– hodnota dílku 0,0127 mm / 0,0005”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"0,8 µm / 0,000031”"},{"name":"– hodnota dílku 0,0254 mm / 0,001”","range":"0 mm to 6,35 mm / 0” to 0,250”","cmc":"1,5 µm / 0,000060”"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Analogové palcové úchylkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) – hodnota dílku 0,00127 mm / 0,00005” – hodnota dílku 0,00254 mm / 0,00010” – hodnota dílku 0,00635 mm / 0,00025” – hodnota dílku 0,0127 mm / 0,0005” – hodnota dílku 0,0254 mm / 0,001” Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové palcové úchylkoměry"},{"_id":"79c1df1ee643338321cfa470","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe calowe","test_object_en":"Analogue inch dial gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– dz. element. 0,00254 mm / 0,0001”","range":"0 mm do 25,4 mm / 0” do 1,000”","cmc":"0,8 µm / 0,000030”"},{"name":"– dz. element. 0,0254 mm / 0,001”","range":"0 mm do 25,4 mm / 0” do 1,000”","cmc":"1,7 µm / 0,000065”"},{"name":"– dz. element. 0,254 mm / 0,01”","range":"0 mm do 25,4 mm / 0” do 1,000”","cmc":"14,7 µm / 0,00058”"}],"parameters_en":[{"name":"– scale int. 0,00254 mm / 0,0001”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"0,8 µm / 0,000030”"},{"name":"– scale int. 0,0254 mm / 0,001”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"1,7 µm / 0,000065”"},{"name":"– scale int. 0,254 mm / 0,01”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"14,7 µm / 0,00058”"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– dz. element. 0,00254 mm / 0,0001” 0 mm do 25,4 mm / 0” do 1,000” CMC 0,8 µm / 0,000030”\n– dz. element. 0,0254 mm / 0,001” 0 mm do 25,4 mm / 0” do 1,000” CMC 1,7 µm / 0,000065”\n– dz. element. 0,254 mm / 0,01” 0 mm do 25,4 mm / 0” do 1,000” CMC 14,7 µm / 0,00058”\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe calowe Wzorcowanie — Długość\nZakres:\n– dz. element. 0,00254 mm / 0,0001” 0 mm do 25,4 mm / 0” do 1,000” CMC 0,8 µm / 0,000030”\n– dz. element. 0,0254 mm / 0,001” 0 mm do 25,4 mm / 0” do 1,000” CMC 1,7 µm / 0,000065”\n– dz. element. 0,254 mm / 0,01” 0 mm do 25,4 mm / 0” do 1,000” CMC 14,7 µm / 0,00058”\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki analogowe calowe Wzorcowanie — Dlugosc\nZakres:\n– dz. element. 0,00254 mm / 0,0001” 0 mm do 25,4 mm / 0” do 1,000” CMC 0,8 µm / 0,000030”\n– dz. element. 0,0254 mm / 0,001” 0 mm do 25,4 mm / 0” do 1,000” CMC 1,7 µm / 0,000065”\n– dz. element. 0,254 mm / 0,01” 0 mm do 25,4 mm / 0” do 1,000” CMC 14,7 µm / 0,00058”\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Analogue inch dial gauges Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) – scale int. 0,00254 mm / 0,0001” – scale int. 0,0254 mm / 0,001” – scale int. 0,254 mm / 0,01” Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Skalenteilungswert 0,00254 mm / 0,0001”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"0,8 µm / 0,000030”"},{"name":"– Skalenteilungswert 0,0254 mm / 0,001”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"1,7 µm / 0,000065”"},{"name":"– Skalenteilungswert 0,254 mm / 0,01”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"14,7 µm / 0,00058”"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Analoge Zoll-Messuhren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) – Skalenteilungswert 0,00254 mm / 0,0001” – Skalenteilungswert 0,0254 mm / 0,001” – Skalenteilungswert 0,254 mm / 0,01” Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Analoge Zoll-Messuhren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 分度值 0,00254 mm / 0,0001”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"0,8 µm / 0,000030”"},{"name":"– 分度值 0,0254 mm / 0,001”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"1,7 µm / 0,000065”"},{"name":"– 分度值 0,254 mm / 0,01”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"14,7 µm / 0,00058”"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"英制模拟指示表 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) – 分度值 0,00254 mm / 0,0001” – 分度值 0,0254 mm / 0,001” – 分度值 0,254 mm / 0,01” 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"英制模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– hodnota dílku 0,00254 mm / 0,0001”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"0,8 µm / 0,000030”"},{"name":"– hodnota dílku 0,0254 mm / 0,001”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"1,7 µm / 0,000065”"},{"name":"– hodnota dílku 0,254 mm / 0,01”","range":"0 mm to 25,4 mm / 0” to 1,000”","cmc":"14,7 µm / 0,00058”"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Analogové palcové úchylkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) – hodnota dílku 0,00254 mm / 0,0001” – hodnota dílku 0,0254 mm / 0,001” – hodnota dílku 0,254 mm / 0,01” Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové palcové úchylkoměry"},{"_id":"a280f438ca141894f6d2b2fb","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe calowe\n– dz. element. 0,0254 mm / 0,001”\n– dz. element. 0,127 mm / 0,005”","test_object_en":"Analogue inch dial gauges\n– scale int. 0,0254 mm / 0,001”\n– scale int. 0,127 mm / 0,005”","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50,8 mm / 0” do 2,000”","cmc":"2,0 µm / 0,00008”"},{"name":"","range":"0 mm do 76,2 mm / 0” do 3,000”","cmc":"2,5 µm / 0,00010”"},{"name":"","range":"0 mm do 101,6 mm / 0” do 4,000”","cmc":"3,0 µm / 0,00012”"}],"parameters_en":[{"name":"","range":"0 mm to 50,8 mm / 0” to 2,000”","cmc":"2,0 µm / 0,00008”"},{"name":"","range":"0 mm to 76,2 mm / 0” to 3,000”","cmc":"2,5 µm / 0,00010”"},{"name":"","range":"0 mm to 101,6 mm / 0” to 4,000”","cmc":"3,0 µm / 0,00012”"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50,8 mm / 0” do 2,000” CMC 2,0 µm / 0,00008”\n0 mm do 76,2 mm / 0” do 3,000” CMC 2,5 µm / 0,00010”\n0 mm do 101,6 mm / 0” do 4,000” CMC 3,0 µm / 0,00012”\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe calowe\n– dz. element. 0,0254 mm / 0,001”\n– dz. element. 0,127 mm / 0,005” Wzorcowanie — Długość\nZakres:\n0 mm do 50,8 mm / 0” do 2,000” CMC 2,0 µm / 0,00008”\n0 mm do 76,2 mm / 0” do 3,000” CMC 2,5 µm / 0,00010”\n0 mm do 101,6 mm / 0” do 4,000” CMC 3,0 µm / 0,00012”\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki analogowe calowe\n– dz. element. 0,0254 mm / 0,001”\n– dz. element. 0,127 mm / 0,005” Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50,8 mm / 0” do 2,000” CMC 2,0 µm / 0,00008”\n0 mm do 76,2 mm / 0” do 3,000” CMC 2,5 µm / 0,00010”\n0 mm do 101,6 mm / 0” do 4,000” CMC 3,0 µm / 0,00012”\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Analogue inch dial gauges – scale int. 0,0254 mm / 0,001” – scale int. 0,127 mm / 0,005” Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 50,8 mm / 0” to 2,000”","cmc":"2,0 µm / 0,00008”"},{"name":"","range":"0 mm to 76,2 mm / 0” to 3,000”","cmc":"2,5 µm / 0,00010”"},{"name":"","range":"0 mm to 101,6 mm / 0” to 4,000”","cmc":"3,0 µm / 0,00012”"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Analoge Zoll-Messuhren – Skalenteilungswert 0,0254 mm / 0,001” – Skalenteilungswert 0,127 mm / 0,005” Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Analoge Zoll-Messuhren\n– Skalenteilungswert 0,0254 mm / 0,001”\n– Skalenteilungswert 0,127 mm / 0,005”","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 50,8 mm / 0” to 2,000”","cmc":"2,0 µm / 0,00008”"},{"name":"","range":"0 mm to 76,2 mm / 0” to 3,000”","cmc":"2,5 µm / 0,00010”"},{"name":"","range":"0 mm to 101,6 mm / 0” to 4,000”","cmc":"3,0 µm / 0,00012”"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"英制模拟指示表 – 分度值 0,0254 mm / 0,001” – 分度值 0,127 mm / 0,005” 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"英制模拟指示表\n– 分度值 0,0254 mm / 0,001”\n– 分度值 0,127 mm / 0,005”","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 50,8 mm / 0” to 2,000”","cmc":"2,0 µm / 0,00008”"},{"name":"","range":"0 mm to 76,2 mm / 0” to 3,000”","cmc":"2,5 µm / 0,00010”"},{"name":"","range":"0 mm to 101,6 mm / 0” to 4,000”","cmc":"3,0 µm / 0,00012”"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Analogové palcové úchylkoměry – hodnota dílku 0,0254 mm / 0,001” – hodnota dílku 0,127 mm / 0,005” Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové palcové úchylkoměry\n– hodnota dílku 0,0254 mm / 0,001”\n– hodnota dílku 0,127 mm / 0,005”"},{"_id":"8b26035ef729e0447cf25f79","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki analogowe calowe z uchylnym trzpieniem\n– dz. element. 0,00254 mm/ 0,0001”\n– dz. element. 0,00127 mm / 0,00005”\n– dz. element. 0,0127 mm / 0,0005”","test_object_en":"Analogue inch lever dial gauges\n– scale int. 0,00254 mm/ 0,0001”\n– scale int. 0,00127 mm / 0,00005”\n– scale int. 0,0127 mm / 0,0005”","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"-0,030” do 0,030”","cmc":"0,3 µm / 0,000013”"},{"name":"","range":"-0,030” do 0,030”","cmc":"0,8 µm / 0,000030”"}],"parameters_en":[{"name":"","range":"-0,030” to 0,030”","cmc":"0,3 µm / 0,000013”"},{"name":"","range":"-0,030” to 0,030”","cmc":"0,8 µm / 0,000030”"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n-0,030” do 0,030” CMC 0,3 µm / 0,000013”\n-0,030” do 0,030” CMC 0,8 µm / 0,000030”\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe calowe z uchylnym trzpieniem\n– dz. element. 0,00254 mm/ 0,0001”\n– dz. element. 0,00127 mm / 0,00005”\n– dz. element. 0,0127 mm / 0,0005” Wzorcowanie — Długość\nZakres:\n-0,030” do 0,030” CMC 0,3 µm / 0,000013”\n-0,030” do 0,030” CMC 0,8 µm / 0,000030”\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki analogowe calowe z uchylnym trzpieniem\n– dz. element. 0,00254 mm/ 0,0001”\n– dz. element. 0,00127 mm / 0,00005”\n– dz. element. 0,0127 mm / 0,0005” Wzorcowanie — Dlugosc\nZakres:\n-0,030” do 0,030” CMC 0,3 µm / 0,000013”\n-0,030” do 0,030” CMC 0,8 µm / 0,000030”\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Analogue inch lever dial gauges – scale int. 0,00254 mm/ 0,0001” – scale int. 0,00127 mm / 0,00005” – scale int. 0,0127 mm / 0,0005” Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"-0,030” to 0,030”","cmc":"0,3 µm / 0,000013”"},{"name":"","range":"-0,030” to 0,030”","cmc":"0,8 µm / 0,000030”"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Analoge Zoll-Fühlhebelmessgeräte – Skalenteilungswert 0,00254 mm/ 0,0001” – Skalenteilungswert 0,00127 mm / 0,00005” – Skalenteilungswert 0,0127 mm / 0,0005” Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Analoge Zoll-Fühlhebelmessgeräte\n– Skalenteilungswert 0,00254 mm/ 0,0001”\n– Skalenteilungswert 0,00127 mm / 0,00005”\n– Skalenteilungswert 0,0127 mm / 0,0005”","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"-0,030” to 0,030”","cmc":"0,3 µm / 0,000013”"},{"name":"","range":"-0,030” to 0,030”","cmc":"0,8 µm / 0,000030”"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"英制模拟杠杆指示表 – 分度值 0,00254 mm/ 0,0001” – 分度值 0,00127 mm / 0,00005” – 分度值 0,0127 mm / 0,0005” 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"英制模拟杠杆指示表\n– 分度值 0,00254 mm/ 0,0001”\n– 分度值 0,00127 mm / 0,00005”\n– 分度值 0,0127 mm / 0,0005”","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"-0,030” to 0,030”","cmc":"0,3 µm / 0,000013”"},{"name":"","range":"-0,030” to 0,030”","cmc":"0,8 µm / 0,000030”"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Analogové palcové páčkové úchylkoměry – hodnota dílku 0,00254 mm/ 0,0001” – hodnota dílku 0,00127 mm / 0,00005” – hodnota dílku 0,0127 mm / 0,0005” Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové palcové páčkové úchylkoměry\n– hodnota dílku 0,00254 mm/ 0,0001”\n– hodnota dílku 0,00127 mm / 0,00005”\n– hodnota dílku 0,0127 mm / 0,0005”"},{"_id":"5f61ddf8a68169a5f83d2d15","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe\n– rozdzielczość 0,0005 mm\n– rozdzielczość 0,0002 mm","test_object_en":"Digital dial gauges\n– resolution 0,0005 mm\n– resolution 0,0002 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 3 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 3 mm","cmc":"0,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 3 mm CMC 0,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe\n– rozdzielczość 0,0005 mm\n– rozdzielczość 0,0002 mm Wzorcowanie — Długość\n0 mm do 3 mm CMC 0,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki cyfrowe\n– rozdzielczosc 0,0005 mm\n– rozdzielczosc 0,0002 mm Wzorcowanie — Dlugosc\n0 mm do 3 mm CMC 0,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Digital dial gauges – resolution 0,0005 mm – resolution 0,0002 mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 3 mm","cmc":"0,5 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Digitale Messuhren – Auflösung 0,0005 mm – Auflösung 0,0002 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren\n– Auflösung 0,0005 mm\n– Auflösung 0,0002 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 3 mm","cmc":"0,5 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"数显指示表 – 分辨力 0,0005 mm – 分辨力 0,0002 mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"数显指示表\n– 分辨力 0,0005 mm\n– 分辨力 0,0002 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 3 mm","cmc":"0,5 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry – rozlišení 0,0005 mm – rozlišení 0,0002 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry\n– rozlišení 0,0005 mm\n– rozlišení 0,0002 mm"},{"_id":"142c41f03e3a0b7daaf84fb0","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe\n– rozdzielczość 0,0005 mm","test_object_en":"Digital dial gauges\n– resolution 0,0005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"0,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,1 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,8 µm"}],"parameters_en":[{"name":"","range":"0 mm do 12,7 mm","cmc":"0,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,1 µm"},{"name":"","range":"0 mm to 50,8 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 0,8 µm\n0 mm do 25,4 mm CMC 1,1 µm\n0 mm do 50,8 mm CMC 2,0 µm\n0 mm do 100 mm CMC 3,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe\n– rozdzielczość 0,0005 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 0,8 µm\n0 mm do 25,4 mm CMC 1,1 µm\n0 mm do 50,8 mm CMC 2,0 µm\n0 mm do 100 mm CMC 3,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki cyfrowe\n– rozdzielczosc 0,0005 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 0,8 µm\n0 mm do 25,4 mm CMC 1,1 µm\n0 mm do 50,8 mm CMC 2,0 µm\n0 mm do 100 mm CMC 3,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Digital dial gauges – resolution 0,0005 mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 12,7 mm","cmc":"0,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,1 µm"},{"name":"","range":"0 mm bis 50,8 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,8 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Digitale Messuhren – Auflösung 0,0005 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren\n– Auflösung 0,0005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 12,7 mm","cmc":"0,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,1 µm"},{"name":"","range":"0 mm 至 50,8 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,8 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"数显指示表 – 分辨力 0,0005 mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"数显指示表\n– 分辨力 0,0005 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 12,7 mm","cmc":"0,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,1 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,8 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry – rozlišení 0,0005 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry\n– rozlišení 0,0005 mm"},{"_id":"039858ba6edf9b5004c0cf16","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe\n– rozdzielczość 0,001 mm","test_object_en":"Digital dial gauges\n– resolution 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"3,4 µm"}],"parameters_en":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm to 50,8 mm","cmc":"3,4 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a Mitutoyo micrometer head","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 2,8 µm\n0 mm do 25,4 mm CMC 2,9 µm\n0 mm do 50,8 mm CMC 3,4 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/05/01","norm_bases":["IW/KUM/05/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe\n– rozdzielczość 0,001 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 2,8 µm\n0 mm do 25,4 mm CMC 2,9 µm\n0 mm do 50,8 mm CMC 3,4 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/05/01 Czujniki cyfrowe\n– rozdzielczosc 0,001 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 2,8 µm\n0 mm do 25,4 mm CMC 2,9 µm\n0 mm do 50,8 mm CMC 3,4 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem glowicy mikrometrycznej Mitutoyo; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/05/01","search_en":"Digital dial gauges – resolution 0,001 mm Calibration — Length Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Length Internal procedure Direct method using a Mitutoyo micrometer head At permanent location (S) Internal procedure IW/KUM/05/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/05/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm bis 50,8 mm","cmc":"3,4 µm"}],"reference_de":"Internes Verfahren IW/KUM/05/01","regulatory_area_de":"Länge","search_de":"Digitale Messuhren – Auflösung 0,001 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf Am festen Standort (S) Internes Verfahren IW/KUM/05/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren\n– Auflösung 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm 至 50,8 mm","cmc":"3,4 µm"}],"reference_zh":"内部程序 IW/KUM/05/01","regulatory_area_zh":"长度","search_zh":"数显指示表 – 分辨力 0,001 mm 校准 — 长度 内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo测微头的直接法 在固定地点 (S) 内部程序 IW/KUM/05/01","technique_zh":"内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo测微头的直接法","在固定地点 (S)"],"test_object_zh":"数显指示表\n– 分辨力 0,001 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,9 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"3,4 µm"}],"reference_cs":"Vnitřní postup IW/KUM/05/01","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry – rozlišení 0,001 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím mikrometrické hlavice Mitutoyo Ve stálé lokalitě (S) Vnitřní postup IW/KUM/05/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím mikrometrické hlavice Mitutoyo","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry\n– rozlišení 0,001 mm"},{"_id":"7b0e45c6447b1b2dbf2d077d","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe\n– rozdzielczość 0,002 mm\n– rozdzielczość 0,001 mm","test_object_en":"Digital dial gauges\n– resolution 0,002 mm\n– resolution 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,0 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,9 µm"}],"parameters_en":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,0 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm to 50,8 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 1,0 µm\n0 mm do 25,4 mm CMC 1,3 µm\n0 mm do 50,8 mm CMC 2,1 µm\n0 mm do 100 mm CMC 3,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe\n– rozdzielczość 0,002 mm\n– rozdzielczość 0,001 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 1,0 µm\n0 mm do 25,4 mm CMC 1,3 µm\n0 mm do 50,8 mm CMC 2,1 µm\n0 mm do 100 mm CMC 3,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki cyfrowe\n– rozdzielczosc 0,002 mm\n– rozdzielczosc 0,001 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 1,0 µm\n0 mm do 25,4 mm CMC 1,3 µm\n0 mm do 50,8 mm CMC 2,1 µm\n0 mm do 100 mm CMC 3,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Digital dial gauges – resolution 0,002 mm – resolution 0,001 mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,0 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm bis 50,8 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,9 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Digitale Messuhren – Auflösung 0,002 mm – Auflösung 0,001 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren\n– Auflösung 0,002 mm\n– Auflösung 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,0 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm 至 50,8 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,9 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"数显指示表 – 分辨力 0,002 mm – 分辨力 0,001 mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"数显指示表\n– 分辨力 0,002 mm\n– 分辨力 0,001 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,0 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"1,3 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"2,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"3,9 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry – rozlišení 0,002 mm – rozlišení 0,001 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry\n– rozlišení 0,002 mm\n– rozlišení 0,001 mm"},{"_id":"e2c48a3f07b570d5537b22bc","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe\n– rozdzielczość 0,005 mm","test_object_en":"Digital dial gauges\n– resolution 0,005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,2 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"3,6 µm"}],"parameters_en":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,2 µm"},{"name":"","range":"0 mm to 50,8 mm","cmc":"3,6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a Mitutoyo micrometer head","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 3,1 µm\n0 mm do 25,4 mm CMC 3,2 µm\n0 mm do 50,8 mm CMC 3,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/05/01","norm_bases":["IW/KUM/05/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe\n– rozdzielczość 0,005 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 3,1 µm\n0 mm do 25,4 mm CMC 3,2 µm\n0 mm do 50,8 mm CMC 3,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/05/01 Czujniki cyfrowe\n– rozdzielczosc 0,005 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 3,1 µm\n0 mm do 25,4 mm CMC 3,2 µm\n0 mm do 50,8 mm CMC 3,6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem glowicy mikrometrycznej Mitutoyo; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/05/01","search_en":"Digital dial gauges – resolution 0,005 mm Calibration — Length Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Length Internal procedure Direct method using a Mitutoyo micrometer head At permanent location (S) Internal procedure IW/KUM/05/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/05/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,2 µm"},{"name":"","range":"0 mm bis 50,8 mm","cmc":"3,6 µm"}],"reference_de":"Internes Verfahren IW/KUM/05/01","regulatory_area_de":"Länge","search_de":"Digitale Messuhren – Auflösung 0,005 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf Am festen Standort (S) Internes Verfahren IW/KUM/05/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren\n– Auflösung 0,005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,2 µm"},{"name":"","range":"0 mm 至 50,8 mm","cmc":"3,6 µm"}],"reference_zh":"内部程序 IW/KUM/05/01","regulatory_area_zh":"长度","search_zh":"数显指示表 – 分辨力 0,005 mm 校准 — 长度 内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo测微头的直接法 在固定地点 (S) 内部程序 IW/KUM/05/01","technique_zh":"内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo测微头的直接法","在固定地点 (S)"],"test_object_zh":"数显指示表\n– 分辨力 0,005 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,2 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"3,6 µm"}],"reference_cs":"Vnitřní postup IW/KUM/05/01","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry – rozlišení 0,005 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím mikrometrické hlavice Mitutoyo Ve stálé lokalitě (S) Vnitřní postup IW/KUM/05/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím mikrometrické hlavice Mitutoyo","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry\n– rozlišení 0,005 mm"},{"_id":"c9c01098360fea84b393008c","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe\n– rozdzielczość 0,005 mm","test_object_en":"Digital dial gauges\n– resolution 0,005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,1 µm"}],"parameters_en":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm to 50,8 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,1 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 1,8 µm\n0 mm do 25,4 mm CMC 2,0 µm\n0 mm do 50,8 mm CMC 2,5 µm\n0 mm do 100 mm CMC 4,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe\n– rozdzielczość 0,005 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 1,8 µm\n0 mm do 25,4 mm CMC 2,0 µm\n0 mm do 50,8 mm CMC 2,5 µm\n0 mm do 100 mm CMC 4,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki cyfrowe\n– rozdzielczosc 0,005 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 1,8 µm\n0 mm do 25,4 mm CMC 2,0 µm\n0 mm do 50,8 mm CMC 2,5 µm\n0 mm do 100 mm CMC 4,1 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Digital dial gauges – resolution 0,005 mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm bis 50,8 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,1 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Digitale Messuhren – Auflösung 0,005 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren\n– Auflösung 0,005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm 至 50,8 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,1 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"数显指示表 – 分辨力 0,005 mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"数显指示表\n– 分辨力 0,005 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 12,7 mm","cmc":"1,8 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,0 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,1 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry – rozlišení 0,005 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry\n– rozlišení 0,005 mm"},{"_id":"6c6f9c1d69a517512c78c263","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe\n– rozdzielczość 0,01 mm","test_object_en":"Digital dial gauges\n– resolution 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,6 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,7 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"4,1 µm"}],"parameters_en":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,6 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,7 µm"},{"name":"","range":"0 mm to 50,8 mm","cmc":"4,1 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a Mitutoyo micrometer head","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 3,6 µm\n0 mm do 25,4 mm CMC 3,7 µm\n0 mm do 50,8 mm CMC 4,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/05/01","norm_bases":["IW/KUM/05/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe\n– rozdzielczość 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 3,6 µm\n0 mm do 25,4 mm CMC 3,7 µm\n0 mm do 50,8 mm CMC 4,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/05/01 Czujniki cyfrowe\n– rozdzielczosc 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 3,6 µm\n0 mm do 25,4 mm CMC 3,7 µm\n0 mm do 50,8 mm CMC 4,1 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem glowicy mikrometrycznej Mitutoyo; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/05/01","search_en":"Digital dial gauges – resolution 0,01 mm Calibration — Length Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Length Internal procedure Direct method using a Mitutoyo micrometer head At permanent location (S) Internal procedure IW/KUM/05/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/05/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,6 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,7 µm"},{"name":"","range":"0 mm bis 50,8 mm","cmc":"4,1 µm"}],"reference_de":"Internes Verfahren IW/KUM/05/01","regulatory_area_de":"Länge","search_de":"Digitale Messuhren – Auflösung 0,01 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf Am festen Standort (S) Internes Verfahren IW/KUM/05/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren\n– Auflösung 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,6 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,7 µm"},{"name":"","range":"0 mm 至 50,8 mm","cmc":"4,1 µm"}],"reference_zh":"内部程序 IW/KUM/05/01","regulatory_area_zh":"长度","search_zh":"数显指示表 – 分辨力 0,01 mm 校准 — 长度 内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo测微头的直接法 在固定地点 (S) 内部程序 IW/KUM/05/01","technique_zh":"内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo测微头的直接法","在固定地点 (S)"],"test_object_zh":"数显指示表\n– 分辨力 0,01 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,6 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,7 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"4,1 µm"}],"reference_cs":"Vnitřní postup IW/KUM/05/01","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry – rozlišení 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím mikrometrické hlavice Mitutoyo Ve stálé lokalitě (S) Vnitřní postup IW/KUM/05/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím mikrometrické hlavice Mitutoyo","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry\n– rozlišení 0,01 mm"},{"_id":"5de62998853074ada5e8877a","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe\n– rozdzielczość 0,01 mm","test_object_en":"Digital dial gauges\n– resolution 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,7 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,5 µm"}],"parameters_en":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,7 µm"},{"name":"","range":"0 mm to 50,8 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 2,5 µm\n0 mm do 25,4 mm CMC 2,7 µm\n0 mm do 50,8 mm CMC 3,1 µm\n0 mm do 100 mm CMC 4,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe\n– rozdzielczość 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 2,5 µm\n0 mm do 25,4 mm CMC 2,7 µm\n0 mm do 50,8 mm CMC 3,1 µm\n0 mm do 100 mm CMC 4,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki cyfrowe\n– rozdzielczosc 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 2,5 µm\n0 mm do 25,4 mm CMC 2,7 µm\n0 mm do 50,8 mm CMC 3,1 µm\n0 mm do 100 mm CMC 4,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Digital dial gauges – resolution 0,01 mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,7 µm"},{"name":"","range":"0 mm bis 50,8 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,5 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Digitale Messuhren – Auflösung 0,01 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren\n– Auflösung 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,7 µm"},{"name":"","range":"0 mm 至 50,8 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,5 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"数显指示表 – 分辨力 0,01 mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"数显指示表\n– 分辨力 0,01 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 12,7 mm","cmc":"2,5 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"2,7 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"3,1 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"4,5 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry – rozlišení 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry\n– rozlišení 0,01 mm"},{"_id":"ee4e83a66891306ae1011c92","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe\n– rozdzielczość 0,02 mm","test_object_en":"Digital dial gauges\n– resolution 0,02 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,3 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,4 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"3,8 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"5,0 µm"}],"parameters_en":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,3 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,4 µm"},{"name":"","range":"0 mm to 50,8 mm","cmc":"3,8 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"5,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 3,3 µm\n0 mm do 25,4 mm CMC 3,4 µm\n0 mm do 50,8 mm CMC 3,8 µm\n0 mm do 100 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe\n– rozdzielczość 0,02 mm Wzorcowanie — Długość\nZakres:\n0 mm do 12,7 mm CMC 3,3 µm\n0 mm do 25,4 mm CMC 3,4 µm\n0 mm do 50,8 mm CMC 3,8 µm\n0 mm do 100 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki cyfrowe\n– rozdzielczosc 0,02 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 12,7 mm CMC 3,3 µm\n0 mm do 25,4 mm CMC 3,4 µm\n0 mm do 50,8 mm CMC 3,8 µm\n0 mm do 100 mm CMC 5,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Digital dial gauges – resolution 0,02 mm Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,3 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,4 µm"},{"name":"","range":"0 mm bis 50,8 mm","cmc":"3,8 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"5,0 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Digitale Messuhren – Auflösung 0,02 mm Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren\n– Auflösung 0,02 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,3 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,4 µm"},{"name":"","range":"0 mm 至 50,8 mm","cmc":"3,8 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"5,0 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"数显指示表 – 分辨力 0,02 mm 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"数显指示表\n– 分辨力 0,02 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 12,7 mm","cmc":"3,3 µm"},{"name":"","range":"0 mm do 25,4 mm","cmc":"3,4 µm"},{"name":"","range":"0 mm do 50,8 mm","cmc":"3,8 µm"},{"name":"","range":"0 mm do 100 mm","cmc":"5,0 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry – rozlišení 0,02 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry\n– rozlišení 0,02 mm"},{"_id":"b933ddc9861749d8189caf30","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe z uchylnym trzpieniem","test_object_en":"Digital lever dial gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– rozdzielczość 0,01 mm","range":"0 mm do 1 mm","cmc":"3,3 µm"},{"name":"– rozdzielczość 0,001 mm","range":"0 mm do 1 mm","cmc":"0,9 µm"}],"parameters_en":[{"name":"– resolution 0,01 mm","range":"0 mm to 1 mm","cmc":"3,3 µm"},{"name":"– resolution 0,001 mm","range":"0 mm to 1 mm","cmc":"0,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR OPTIMAR 100 instrument","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– rozdzielczość 0,01 mm 0 mm do 1 mm CMC 3,3 µm\n– rozdzielczość 0,001 mm 0 mm do 1 mm CMC 0,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/18/01","norm_bases":["IW/KUM/18/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe z uchylnym trzpieniem Wzorcowanie — Długość\nZakres:\n– rozdzielczość 0,01 mm 0 mm do 1 mm CMC 3,3 µm\n– rozdzielczość 0,001 mm 0 mm do 1 mm CMC 0,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem przyrządu MAHR OPTIMAR 100; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/18/01 Czujniki cyfrowe z uchylnym trzpieniem Wzorcowanie — Dlugosc\nZakres:\n– rozdzielczosc 0,01 mm 0 mm do 1 mm CMC 3,3 µm\n– rozdzielczosc 0,001 mm 0 mm do 1 mm CMC 0,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem przyrzadu MAHR OPTIMAR 100; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/18/01","search_en":"Digital lever dial gauges Calibration — Length Internal procedure; Direct method using a MAHR OPTIMAR 100 instrument; At permanent location (S) Length Internal procedure Direct method using a MAHR OPTIMAR 100 instrument At permanent location (S) – resolution 0,01 mm – resolution 0,001 mm Internal procedure IW/KUM/18/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/18/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Auflösung 0,01 mm","range":"0 mm to 1 mm","cmc":"3,3 µm"},{"name":"– Auflösung 0,001 mm","range":"0 mm to 1 mm","cmc":"0,9 µm"}],"reference_de":"Internes Verfahren IW/KUM/18/01","regulatory_area_de":"Länge","search_de":"Digitale Fühlhebelmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100 Am festen Standort (S) – Auflösung 0,01 mm – Auflösung 0,001 mm Internes Verfahren IW/KUM/18/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Gerät MAHR OPTIMAR 100","Am festen Standort (S)"],"test_object_de":"Digitale Fühlhebelmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 分辨力 0,01 mm","range":"0 mm to 1 mm","cmc":"3,3 µm"},{"name":"– 分辨力 0,001 mm","range":"0 mm to 1 mm","cmc":"0,9 µm"}],"reference_zh":"内部程序 IW/KUM/18/01","regulatory_area_zh":"长度","search_zh":"数显杠杆千分表 校准 — 长度 内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S) 长度 内部程序 使用MAHR OPTIMAR 100仪器的直接法 在固定地点 (S) – 分辨力 0,01 mm – 分辨力 0,001 mm 内部程序 IW/KUM/18/01","technique_zh":"内部程序；使用MAHR OPTIMAR 100仪器的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR OPTIMAR 100仪器的直接法","在固定地点 (S)"],"test_object_zh":"数显杠杆千分表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– rozlišení 0,01 mm","range":"0 mm to 1 mm","cmc":"3,3 µm"},{"name":"– rozlišení 0,001 mm","range":"0 mm to 1 mm","cmc":"0,9 µm"}],"reference_cs":"Vnitřní postup IW/KUM/18/01","regulatory_area_cs":"Délka","search_cs":"Digitální páčkové úchylkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím přístroje MAHR OPTIMAR 100 Ve stálé lokalitě (S) – rozlišení 0,01 mm – rozlišení 0,001 mm Vnitřní postup IW/KUM/18/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím přístroje MAHR OPTIMAR 100; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím přístroje MAHR OPTIMAR 100","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální páčkové úchylkoměry"},{"_id":"3a04b150a7c9bcfbe7e6303d","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki cyfrowe z uchylnym trzpieniem","test_object_en":"Digital lever dial gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– rozdzielczość 0,01 mm","range":"0 mm do 1 mm","cmc":"3,4 µm"},{"name":"– rozdzielczość 0,005 mm","range":"0 mm do 1 mm","cmc":"2,9 µm"},{"name":"– rozdzielczość 0,001 mm","range":"0 mm do 1 mm","cmc":"2,5 µm"}],"parameters_en":[{"name":"– resolution 0,01 mm","range":"0 mm to 1 mm","cmc":"3,4 µm"},{"name":"– resolution 0,005 mm","range":"0 mm to 1 mm","cmc":"2,9 µm"},{"name":"– resolution 0,001 mm","range":"0 mm to 1 mm","cmc":"2,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a Mitutoyo micrometer head","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– rozdzielczość 0,01 mm 0 mm do 1 mm CMC 3,4 µm\n– rozdzielczość 0,005 mm 0 mm do 1 mm CMC 2,9 µm\n– rozdzielczość 0,001 mm 0 mm do 1 mm CMC 2,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/05/01","norm_bases":["IW/KUM/05/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe z uchylnym trzpieniem Wzorcowanie — Długość\nZakres:\n– rozdzielczość 0,01 mm 0 mm do 1 mm CMC 3,4 µm\n– rozdzielczość 0,005 mm 0 mm do 1 mm CMC 2,9 µm\n– rozdzielczość 0,001 mm 0 mm do 1 mm CMC 2,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem głowicy mikrometrycznej Mitutoyo; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/05/01 Czujniki cyfrowe z uchylnym trzpieniem Wzorcowanie — Dlugosc\nZakres:\n– rozdzielczosc 0,01 mm 0 mm do 1 mm CMC 3,4 µm\n– rozdzielczosc 0,005 mm 0 mm do 1 mm CMC 2,9 µm\n– rozdzielczosc 0,001 mm 0 mm do 1 mm CMC 2,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem glowicy mikrometrycznej Mitutoyo; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/05/01","search_en":"Digital lever dial gauges Calibration — Length Internal procedure; Direct method using a Mitutoyo micrometer head; At permanent location (S) Length Internal procedure Direct method using a Mitutoyo micrometer head At permanent location (S) – resolution 0,01 mm – resolution 0,005 mm – resolution 0,001 mm Internal procedure IW/KUM/05/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/05/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Auflösung 0,01 mm","range":"0 mm to 1 mm","cmc":"3,4 µm"},{"name":"– Auflösung 0,005 mm","range":"0 mm to 1 mm","cmc":"2,9 µm"},{"name":"– Auflösung 0,001 mm","range":"0 mm to 1 mm","cmc":"2,5 µm"}],"reference_de":"Internes Verfahren IW/KUM/05/01","regulatory_area_de":"Länge","search_de":"Digitale Fühlhebelmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf Am festen Standort (S) – Auflösung 0,01 mm – Auflösung 0,005 mm – Auflösung 0,001 mm Internes Verfahren IW/KUM/05/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Mitutoyo-Messschraubenkopf","Am festen Standort (S)"],"test_object_de":"Digitale Fühlhebelmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 分辨力 0,01 mm","range":"0 mm to 1 mm","cmc":"3,4 µm"},{"name":"– 分辨力 0,005 mm","range":"0 mm to 1 mm","cmc":"2,9 µm"},{"name":"– 分辨力 0,001 mm","range":"0 mm to 1 mm","cmc":"2,5 µm"}],"reference_zh":"内部程序 IW/KUM/05/01","regulatory_area_zh":"长度","search_zh":"数显杠杆千分表 校准 — 长度 内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo测微头的直接法 在固定地点 (S) – 分辨力 0,01 mm – 分辨力 0,005 mm – 分辨力 0,001 mm 内部程序 IW/KUM/05/01","technique_zh":"内部程序；使用Mitutoyo测微头的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo测微头的直接法","在固定地点 (S)"],"test_object_zh":"数显杠杆千分表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– rozlišení 0,01 mm","range":"0 mm to 1 mm","cmc":"3,4 µm"},{"name":"– rozlišení 0,005 mm","range":"0 mm to 1 mm","cmc":"2,9 µm"},{"name":"– rozlišení 0,001 mm","range":"0 mm to 1 mm","cmc":"2,5 µm"}],"reference_cs":"Vnitřní postup IW/KUM/05/01","regulatory_area_cs":"Délka","search_cs":"Digitální páčkové úchylkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím mikrometrické hlavice Mitutoyo Ve stálé lokalitě (S) – rozlišení 0,01 mm – rozlišení 0,005 mm – rozlišení 0,001 mm Vnitřní postup IW/KUM/05/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím mikrometrické hlavice Mitutoyo; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím mikrometrické hlavice Mitutoyo","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální páčkové úchylkoměry"},{"_id":"9258f1ebdb588ac2014cd3ca","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Czujniki optyczne","test_object_en":"Optical probes","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– MOP 02/20","range":"-20 µm do 20 µm","cmc":"0,12 µm"},{"name":"– MOP 1/100","range":"-100 µm do 100 µm","cmc":"0,13 µm"}],"parameters_en":[{"name":"– MOP 02/20","range":"-20 µm to 20 µm","cmc":"0,12 µm"},{"name":"– MOP 1/100","range":"-100 µm to 100 µm","cmc":"0,13 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– MOP 02/20 -20 µm do 20 µm CMC 0,12 µm\n– MOP 1/100 -100 µm do 100 µm CMC 0,13 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna IW/KUM/12/01","norm_bases":["IW/KUM/12/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Czujniki optyczne Wzorcowanie — Długość\nZakres:\n– MOP 02/20 -20 µm do 20 µm CMC 0,12 µm\n– MOP 1/100 -100 µm do 100 µm CMC 0,13 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna IW/KUM/12/01 Czujniki optyczne Wzorcowanie — Dlugosc\nZakres:\n– MOP 02/20 -20 µm do 20 µm CMC 0,12 µm\n– MOP 1/100 -100 µm do 100 µm CMC 0,13 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna IW/KUM/12/01","search_en":"Optical probes Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P) Length Internal procedure Direct method using gauge blocks At permanent location (S) and outside of it (P) – MOP 02/20 – MOP 1/100 Internal procedure IW/KUM/12/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/12/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– MOP 02/20","range":"-20 µm to 20 µm","cmc":"0,12 µm"},{"name":"– MOP 1/100","range":"-100 µm to 100 µm","cmc":"0,13 µm"}],"reference_de":"Internes Verfahren IW/KUM/12/01","regulatory_area_de":"Länge","search_de":"Optische Messtaster Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) und außerhalb (P) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) und außerhalb (P) – MOP 02/20 – MOP 1/100 Internes Verfahren IW/KUM/12/01","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Optische Messtaster","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– MOP 02/20","range":"-20 µm to 20 µm","cmc":"0,12 µm"},{"name":"– MOP 1/100","range":"-100 µm to 100 µm","cmc":"0,13 µm"}],"reference_zh":"内部程序 IW/KUM/12/01","regulatory_area_zh":"长度","search_zh":"光学测头 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 及固定地点以外 (P) 长度 内部程序 使用量块的直接法 在固定地点 (S) 及固定地点以外 (P) – MOP 02/20 – MOP 1/100 内部程序 IW/KUM/12/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"光学测头","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– MOP 02/20","range":"-20 µm to 20 µm","cmc":"0,12 µm"},{"name":"– MOP 1/100","range":"-100 µm to 100 µm","cmc":"0,13 µm"}],"reference_cs":"Vnitřní postup IW/KUM/12/01","regulatory_area_cs":"Délka","search_cs":"Optické snímače Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; V trvalé lokalitě (S) i mimo ni (P) Délka Vnitřní postup Přímá metoda s použitím koncových měrek V trvalé lokalitě (S) i mimo ni (P) – MOP 02/20 – MOP 1/100 Vnitřní postup IW/KUM/12/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Optické snímače"},{"_id":"608588462eaad5ace6153b98","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Długościomierze pionowe Abbego","test_object_en":"Abbe vertical length measuring machines","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– błąd pomiaru długościomierza","range":"0 mm do 100 mm","cmc":"Q[0,11; 3,4∙L] µm"},{"name":"– błąd pomiaru mikroskopu odczytowego","range":"0 mm do 100 mm","cmc":"0,12 µm"}],"parameters_en":[{"name":"– length measuring machine measurement error","range":"0 mm to 100 mm","cmc":"Q[0,11; 3,4∙L] µm"},{"name":"– reading microscope measurement error","range":"0 mm to 100 mm","cmc":"0,12 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– błąd pomiaru długościomierza 0 mm do 100 mm CMC Q[0,11; 3,4∙L] µm\n– błąd pomiaru mikroskopu odczytowego 0 mm do 100 mm CMC 0,12 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna IW/KUM/12/02","norm_bases":["IW/KUM/12/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"S, P","note":"L- wielkość mierzona (m)","note_en":"L- measured quantity (m)","search_text":"Długościomierze pionowe Abbego Wzorcowanie — Długość\nZakres:\n– błąd pomiaru długościomierza 0 mm do 100 mm CMC Q[0,11; 3,4∙L] µm\n– błąd pomiaru mikroskopu odczytowego 0 mm do 100 mm CMC 0,12 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna IW/KUM/12/02 Dlugosciomierze pionowe Abbego Wzorcowanie — Dlugosc\nZakres:\n– blad pomiaru dlugosciomierza 0 mm do 100 mm CMC Q[0,11; 3,4∙L] µm\n– blad pomiaru mikroskopu odczytowego 0 mm do 100 mm CMC 0,12 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna IW/KUM/12/02","search_en":"Abbe vertical length measuring machines Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P) Length Internal procedure Direct method using gauge blocks At permanent location (S) and outside of it (P) – length measuring machine measurement error – reading microscope measurement error Internal procedure IW/KUM/12/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/12/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Messfehler des Längenmessgeräts","range":"0 mm to 100 mm","cmc":"Q[0,11; 3,4∙L] µm"},{"name":"– Messfehler des Ablesemikroskops","range":"0 mm to 100 mm","cmc":"0,12 µm"}],"reference_de":"Internes Verfahren IW/KUM/12/02","regulatory_area_de":"Länge","search_de":"Vertikale Abbe-Längenmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) und außerhalb (P) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) und außerhalb (P) – Messfehler des Längenmessgeräts – Messfehler des Ablesemikroskops Internes Verfahren IW/KUM/12/02","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Vertikale Abbe-Längenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 测长仪测量误差","range":"0 mm to 100 mm","cmc":"Q[0,11; 3,4∙L] µm"},{"name":"– 读数显微镜测量误差","range":"0 mm to 100 mm","cmc":"0,12 µm"}],"reference_zh":"内部程序 IW/KUM/12/02","regulatory_area_zh":"长度","search_zh":"立式阿贝测长仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 及固定地点以外 (P) 长度 内部程序 使用量块的直接法 在固定地点 (S) 及固定地点以外 (P) – 测长仪测量误差 – 读数显微镜测量误差 内部程序 IW/KUM/12/02","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"立式阿贝测长仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– chyba měření délkoměru","range":"0 mm to 100 mm","cmc":"Q[0,11; 3,4∙L] µm"},{"name":"– chyba měření odečítacího mikroskopu","range":"0 mm to 100 mm","cmc":"0,12 µm"}],"reference_cs":"Vnitřní postup IW/KUM/12/02","regulatory_area_cs":"Délka","search_cs":"Vertikální Abbeovy délkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; V trvalé lokalitě (S) i mimo ni (P) Délka Vnitřní postup Přímá metoda s použitím koncových měrek V trvalé lokalitě (S) i mimo ni (P) – chyba měření délkoměru – chyba měření odečítacího mikroskopu Vnitřní postup IW/KUM/12/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Vertikální Abbeovy délkoměry"},{"_id":"0de8e9efc8f4cc2cb75b1709","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Długościomierze poziome Abbego","test_object_en":"Abbe horizontal length measuring machines","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– pomiary mikroskopu odczytowego","range":"0 mm do 3 mm","cmc":"0,1 µm"},{"name":"– pomiary zewnętrzne","range":"0 mm do 100 mm","cmc":"0,5 µm"},{"name":"– pomiary wewnętrzne","range":"0 mm do 100 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"– reading microscope measurements","range":"0 mm to 3 mm","cmc":"0,1 µm"},{"name":"– external measurements","range":"0 mm to 100 mm","cmc":"0,5 µm"},{"name":"– internal measurements","range":"0 mm to 100 mm","cmc":"1,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– pomiary mikroskopu odczytowego 0 mm do 3 mm CMC 0,1 µm\n– pomiary zewnętrzne 0 mm do 100 mm CMC 0,5 µm\n– pomiary wewnętrzne 0 mm do 100 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna IW/KUM/12/03","norm_bases":["IW/KUM/12/03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Długościomierze poziome Abbego Wzorcowanie — Długość\nZakres:\n– pomiary mikroskopu odczytowego 0 mm do 3 mm CMC 0,1 µm\n– pomiary zewnętrzne 0 mm do 100 mm CMC 0,5 µm\n– pomiary wewnętrzne 0 mm do 100 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna IW/KUM/12/03 Dlugosciomierze poziome Abbego Wzorcowanie — Dlugosc\nZakres:\n– pomiary mikroskopu odczytowego 0 mm do 3 mm CMC 0,1 µm\n– pomiary zewnetrzne 0 mm do 100 mm CMC 0,5 µm\n– pomiary wewnetrzne 0 mm do 100 mm CMC 1,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna IW/KUM/12/03","search_en":"Abbe horizontal length measuring machines Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P) Length Internal procedure Direct method using gauge blocks At permanent location (S) and outside of it (P) – reading microscope measurements – external measurements – internal measurements Internal procedure IW/KUM/12/03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/12/03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Messungen mit dem Ablesemikroskop","range":"0 mm to 3 mm","cmc":"0,1 µm"},{"name":"– Außenmessungen","range":"0 mm to 100 mm","cmc":"0,5 µm"},{"name":"– Innenmessungen","range":"0 mm to 100 mm","cmc":"1,0 µm"}],"reference_de":"Internes Verfahren IW/KUM/12/03","regulatory_area_de":"Länge","search_de":"Horizontale Abbe-Längenmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) und außerhalb (P) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) und außerhalb (P) – Messungen mit dem Ablesemikroskop – Außenmessungen – Innenmessungen Internes Verfahren IW/KUM/12/03","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Horizontale Abbe-Längenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 读数显微镜测量","range":"0 mm to 3 mm","cmc":"0,1 µm"},{"name":"– 外尺寸测量","range":"0 mm to 100 mm","cmc":"0,5 µm"},{"name":"– 内尺寸测量","range":"0 mm to 100 mm","cmc":"1,0 µm"}],"reference_zh":"内部程序 IW/KUM/12/03","regulatory_area_zh":"长度","search_zh":"卧式阿贝测长仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 及固定地点以外 (P) 长度 内部程序 使用量块的直接法 在固定地点 (S) 及固定地点以外 (P) – 读数显微镜测量 – 外尺寸测量 – 内尺寸测量 内部程序 IW/KUM/12/03","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"卧式阿贝测长仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– měření odečítacím mikroskopem","range":"0 mm to 3 mm","cmc":"0,1 µm"},{"name":"– vnější měření","range":"0 mm to 100 mm","cmc":"0,5 µm"},{"name":"– vnitřní měření","range":"0 mm to 100 mm","cmc":"1,0 µm"}],"reference_cs":"Vnitřní postup IW/KUM/12/03","regulatory_area_cs":"Délka","search_cs":"Horizontální Abbeovy délkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; V trvalé lokalitě (S) i mimo ni (P) Délka Vnitřní postup Přímá metoda s použitím koncových měrek V trvalé lokalitě (S) i mimo ni (P) – měření odečítacím mikroskopem – vnější měření – vnitřní měření Vnitřní postup IW/KUM/12/03","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Horizontální Abbeovy délkoměry"},{"_id":"d095becca5a5fa1a5d18877f","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Długościomierze poziome (maszyny 1-D)","test_object_en":"Horizontal length measuring machines (1-D machines)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– pomiary pinolą","range":"0 mm do 100 mm","cmc":"Q[0,10; 1,27∙L] µm"},{"name":"– pomiary długościomierzem","range":"100 mm do 500 mm","cmc":"Q[0,40; 2,50∙L] µm"}],"parameters_en":[{"name":"– measurements with the quill","range":"0 mm to 100 mm","cmc":"Q[0,10; 1,27∙L] µm"},{"name":"– measurements with the length measuring machine","range":"100 mm to 500 mm","cmc":"Q[0,40; 2,50∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– pomiary pinolą 0 mm do 100 mm CMC Q[0,10; 1,27∙L] µm\n– pomiary długościomierzem 100 mm do 500 mm CMC Q[0,40; 2,50∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna IW/KUM/12/05","norm_bases":["IW/KUM/12/05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"S, P","note":"L- wielkość mierzona (m)","note_en":"L- measured quantity (m)","search_text":"Długościomierze poziome (maszyny 1-D) Wzorcowanie — Długość\nZakres:\n– pomiary pinolą 0 mm do 100 mm CMC Q[0,10; 1,27∙L] µm\n– pomiary długościomierzem 100 mm do 500 mm CMC Q[0,40; 2,50∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna IW/KUM/12/05 Dlugosciomierze poziome (maszyny 1-D) Wzorcowanie — Dlugosc\nZakres:\n– pomiary pinola 0 mm do 100 mm CMC Q[0,10; 1,27∙L] µm\n– pomiary dlugosciomierzem 100 mm do 500 mm CMC Q[0,40; 2,50∙L] µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna IW/KUM/12/05","search_en":"Horizontal length measuring machines (1-D machines) Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P) Length Internal procedure Direct method using gauge blocks At permanent location (S) and outside of it (P) – measurements with the quill – measurements with the length measuring machine Internal procedure IW/KUM/12/05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/12/05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Messungen mit der Pinole","range":"0 mm to 100 mm","cmc":"Q[0,10; 1,27∙L] µm"},{"name":"– Messungen mit dem Längenmessgerät","range":"100 mm to 500 mm","cmc":"Q[0,40; 2,50∙L] µm"}],"reference_de":"Internes Verfahren IW/KUM/12/05","regulatory_area_de":"Länge","search_de":"Horizontale Längenmessgeräte (1-D-Maschinen) Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) und außerhalb (P) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) und außerhalb (P) – Messungen mit der Pinole – Messungen mit dem Längenmessgerät Internes Verfahren IW/KUM/12/05","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Horizontale Längenmessgeräte (1-D-Maschinen)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 用测量轴测量","range":"0 mm to 100 mm","cmc":"Q[0,10; 1,27∙L] µm"},{"name":"– 用测长仪测量","range":"100 mm to 500 mm","cmc":"Q[0,40; 2,50∙L] µm"}],"reference_zh":"内部程序 IW/KUM/12/05","regulatory_area_zh":"长度","search_zh":"卧式测长仪（一维测量机） 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 及固定地点以外 (P) 长度 内部程序 使用量块的直接法 在固定地点 (S) 及固定地点以外 (P) – 用测量轴测量 – 用测长仪测量 内部程序 IW/KUM/12/05","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"卧式测长仪（一维测量机）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– měření pinolou","range":"0 mm to 100 mm","cmc":"Q[0,10; 1,27∙L] µm"},{"name":"– měření délkoměrem","range":"100 mm to 500 mm","cmc":"Q[0,40; 2,50∙L] µm"}],"reference_cs":"Vnitřní postup IW/KUM/12/05","regulatory_area_cs":"Délka","search_cs":"Horizontální délkoměry (1-D stroje) Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; V trvalé lokalitě (S) i mimo ni (P) Délka Vnitřní postup Přímá metoda s použitím koncových měrek V trvalé lokalitě (S) i mimo ni (P) – měření pinolou – měření délkoměrem Vnitřní postup IW/KUM/12/05","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Horizontální délkoměry (1-D stroje)"},{"_id":"e98f30f7c94c857fb669a017","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Folie wzorcowe","test_object_en":"Reference foils","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 µm do 8000 µm","cmc":"Q[1,4; 1,2∙L] µm"}],"parameters_en":[{"name":"","range":"0 µm to 8000 µm","cmc":"Q[1,4; 1,2∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem grubościomierza; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a thickness gauge; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem grubościomierza","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a thickness gauge","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 µm do 8000 µm CMC Q[1,4; 1,2∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem grubościomierza; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/07/06","norm_bases":["IW/KUM/07/06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L- wielkość mierzona (mm)","note_en":"L- measured quantity (mm)","search_text":"Folie wzorcowe Wzorcowanie — Długość\n0 µm do 8000 µm CMC Q[1,4; 1,2∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem grubościomierza; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/07/06 Folie wzorcowe Wzorcowanie — Dlugosc\n0 µm do 8000 µm CMC Q[1,4; 1,2∙L] µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem grubosciomierza; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/07/06","search_en":"Reference foils Calibration — Length Internal procedure; Direct method using a thickness gauge; At permanent location (S) Length Internal procedure Direct method using a thickness gauge At permanent location (S) Internal procedure IW/KUM/07/06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":28,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/07/06","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 µm to 8000 µm","cmc":"Q[1,4; 1,2∙L] µm"}],"reference_de":"Internes Verfahren IW/KUM/07/06","regulatory_area_de":"Länge","search_de":"Referenzfolien Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Dickenmessgerät; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Dickenmessgerät Am festen Standort (S) Internes Verfahren IW/KUM/07/06","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Dickenmessgerät; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Dickenmessgerät","Am festen Standort (S)"],"test_object_de":"Referenzfolien","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 µm to 8000 µm","cmc":"Q[1,4; 1,2∙L] µm"}],"reference_zh":"内部程序 IW/KUM/07/06","regulatory_area_zh":"长度","search_zh":"标准薄膜 校准 — 长度 内部程序；使用测厚仪的直接法；在固定地点 (S) 长度 内部程序 使用测厚仪的直接法 在固定地点 (S) 内部程序 IW/KUM/07/06","technique_zh":"内部程序；使用测厚仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用测厚仪的直接法","在固定地点 (S)"],"test_object_zh":"标准薄膜","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 µm to 8000 µm","cmc":"Q[1,4; 1,2∙L] µm"}],"reference_cs":"Vnitřní postup IW/KUM/07/06","regulatory_area_cs":"Délka","search_cs":"Etalonové fólie Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím tloušťkoměru; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím tloušťkoměru Ve stálé lokalitě (S) Vnitřní postup IW/KUM/07/06","technique_cs":"Vnitřní postup; Přímá metoda s použitím tloušťkoměru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím tloušťkoměru","Ve stálé lokalitě (S)"],"test_object_cs":"Etalonové fólie"},{"_id":"458b31630d5681e60be7096a","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Głębokościomierze czujnikowe","test_object_en":"Dial depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– dz. element. (0,001; 0,002; 0,005) mm","range":"0 mm do 5 mm","cmc":"0,3 µm"},{"name":"– dz. element. 0,01 mm","range":"0 mm do 10 mm","cmc":"0,7 µm"},{"name":"– dz. element. 0,01 mm","range":"0 mm do 30 mm","cmc":"0,8 µm"},{"name":"– dz. element. 0,01 mm","range":"0 mm do 50 mm","cmc":"1,0 µm"},{"name":"– dz. element. 0,1 mm","range":"0 mm do 50 mm","cmc":"6 µm"}],"parameters_en":[{"name":"– scale int. (0,001; 0,002; 0,005) mm","range":"0 mm to 5 mm","cmc":"0,3 µm"},{"name":"– scale int. 0,01 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– scale int. 0,01 mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– scale int. 0,01 mm","range":"0 mm to 50 mm","cmc":"1,0 µm"},{"name":"– scale int. 0,1 mm","range":"0 mm to 50 mm","cmc":"6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– dz. element. (0,001; 0,002; 0,005) mm 0 mm do 5 mm CMC 0,3 µm\n– dz. element. 0,01 mm 0 mm do 10 mm CMC 0,7 µm\n– dz. element. 0,01 mm 0 mm do 30 mm CMC 0,8 µm\n– dz. element. 0,01 mm 0 mm do 50 mm CMC 1,0 µm\n– dz. element. 0,1 mm 0 mm do 50 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/14/02","norm_bases":["IW/KUM/14/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze czujnikowe Wzorcowanie — Długość\nZakres:\n– dz. element. (0,001; 0,002; 0,005) mm 0 mm do 5 mm CMC 0,3 µm\n– dz. element. 0,01 mm 0 mm do 10 mm CMC 0,7 µm\n– dz. element. 0,01 mm 0 mm do 30 mm CMC 0,8 µm\n– dz. element. 0,01 mm 0 mm do 50 mm CMC 1,0 µm\n– dz. element. 0,1 mm 0 mm do 50 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/14/02 Glebokosciomierze czujnikowe Wzorcowanie — Dlugosc\nZakres:\n– dz. element. (0,001; 0,002; 0,005) mm 0 mm do 5 mm CMC 0,3 µm\n– dz. element. 0,01 mm 0 mm do 10 mm CMC 0,7 µm\n– dz. element. 0,01 mm 0 mm do 30 mm CMC 0,8 µm\n– dz. element. 0,01 mm 0 mm do 50 mm CMC 1,0 µm\n– dz. element. 0,1 mm 0 mm do 50 mm CMC 6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/14/02","search_en":"Dial depth gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) – scale int. (0,001; 0,002; 0,005) mm – scale int. 0,01 mm – scale int. 0,01 mm – scale int. 0,01 mm – scale int. 0,1 mm Internal procedure IW/KUM/14/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":29,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/14/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Skalenteilungswert (0,001; 0,002; 0,005) mm","range":"0 mm to 5 mm","cmc":"0,3 µm"},{"name":"– Skalenteilungswert 0,01 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– Skalenteilungswert 0,01 mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– Skalenteilungswert 0,01 mm","range":"0 mm bis 50 mm","cmc":"1,0 µm"},{"name":"– Skalenteilungswert 0,1 mm","range":"0 mm bis 50 mm","cmc":"6 µm"}],"reference_de":"Internes Verfahren IW/KUM/14/02","regulatory_area_de":"Länge","search_de":"Tiefenmessuhren Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) – Skalenteilungswert (0,001; 0,002; 0,005) mm – Skalenteilungswert 0,01 mm – Skalenteilungswert 0,01 mm – Skalenteilungswert 0,01 mm – Skalenteilungswert 0,1 mm Internes Verfahren IW/KUM/14/02","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Tiefenmessuhren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 分度值 (0,001; 0,002; 0,005) mm","range":"0 mm to 5 mm","cmc":"0,3 µm"},{"name":"– 分度值 0,01 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– 分度值 0,01 mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– 分度值 0,01 mm","range":"0 mm 至 50 mm","cmc":"1,0 µm"},{"name":"– 分度值 0,1 mm","range":"0 mm 至 50 mm","cmc":"6 µm"}],"reference_zh":"内部程序 IW/KUM/14/02","regulatory_area_zh":"长度","search_zh":"指示式深度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) – 分度值 (0,001; 0,002; 0,005) mm – 分度值 0,01 mm – 分度值 0,01 mm – 分度值 0,01 mm – 分度值 0,1 mm 内部程序 IW/KUM/14/02","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"指示式深度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– hodnota dílku (0,001; 0,002; 0,005) mm","range":"0 mm to 5 mm","cmc":"0,3 µm"},{"name":"– hodnota dílku 0,01 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– hodnota dílku 0,01 mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– hodnota dílku 0,01 mm","range":"0 mm do 50 mm","cmc":"1,0 µm"},{"name":"– hodnota dílku 0,1 mm","range":"0 mm do 50 mm","cmc":"6 µm"}],"reference_cs":"Vnitřní postup IW/KUM/14/02","regulatory_area_cs":"Délka","search_cs":"Hloubkoměry s úchylkoměrem Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) – hodnota dílku (0,001; 0,002; 0,005) mm – hodnota dílku 0,01 mm – hodnota dílku 0,01 mm – hodnota dílku 0,01 mm – hodnota dílku 0,1 mm Vnitřní postup IW/KUM/14/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Hloubkoměry s úchylkoměrem"},{"_id":"63ad6e9d810719689fd6d2af","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Głębokościomierze czujnikowe","test_object_en":"Dial depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– rozdzielczość (0,001; 0,005; 0,01)mm","range":"0 mm do 10 mm","cmc":"0,7 µm"},{"name":"– rozdzielczość (0,001; 0,005; 0,01)mm","range":"0 mm do 30 mm","cmc":"0,8 µm"},{"name":"– rozdzielczość (0,001; 0,005; 0,01)mm","range":"0 mm do 50 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"– resolution (0,001; 0,005; 0,01)mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– resolution (0,001; 0,005; 0,01)mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– resolution (0,001; 0,005; 0,01)mm","range":"0 mm to 50 mm","cmc":"1,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 10 mm CMC 0,7 µm\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 30 mm CMC 0,8 µm\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 50 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/14/02","norm_bases":["IW/KUM/14/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze czujnikowe Wzorcowanie — Długość\nZakres:\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 10 mm CMC 0,7 µm\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 30 mm CMC 0,8 µm\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 50 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/14/02 Glebokosciomierze czujnikowe Wzorcowanie — Dlugosc\nZakres:\n– rozdzielczosc (0,001; 0,005; 0,01)mm 0 mm do 10 mm CMC 0,7 µm\n– rozdzielczosc (0,001; 0,005; 0,01)mm 0 mm do 30 mm CMC 0,8 µm\n– rozdzielczosc (0,001; 0,005; 0,01)mm 0 mm do 50 mm CMC 1,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/14/02","search_en":"Dial depth gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) – resolution (0,001; 0,005; 0,01)mm – resolution (0,001; 0,005; 0,01)mm – resolution (0,001; 0,005; 0,01)mm Internal procedure IW/KUM/14/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":30,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/14/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Auflösung (0,001; 0,005; 0,01)mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– Auflösung (0,001; 0,005; 0,01)mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– Auflösung (0,001; 0,005; 0,01)mm","range":"0 mm bis 50 mm","cmc":"1,0 µm"}],"reference_de":"Internes Verfahren IW/KUM/14/02","regulatory_area_de":"Länge","search_de":"Tiefenmessuhren Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) – Auflösung (0,001; 0,005; 0,01)mm – Auflösung (0,001; 0,005; 0,01)mm – Auflösung (0,001; 0,005; 0,01)mm Internes Verfahren IW/KUM/14/02","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Tiefenmessuhren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 分辨力 (0,001; 0,005; 0,01)mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– 分辨力 (0,001; 0,005; 0,01)mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– 分辨力 (0,001; 0,005; 0,01)mm","range":"0 mm 至 50 mm","cmc":"1,0 µm"}],"reference_zh":"内部程序 IW/KUM/14/02","regulatory_area_zh":"长度","search_zh":"指示式深度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) – 分辨力 (0,001; 0,005; 0,01)mm – 分辨力 (0,001; 0,005; 0,01)mm – 分辨力 (0,001; 0,005; 0,01)mm 内部程序 IW/KUM/14/02","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"指示式深度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– rozlišení (0,001; 0,005; 0,01)mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– rozlišení (0,001; 0,005; 0,01)mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– rozlišení (0,001; 0,005; 0,01)mm","range":"0 mm do 50 mm","cmc":"1,0 µm"}],"reference_cs":"Vnitřní postup IW/KUM/14/02","regulatory_area_cs":"Délka","search_cs":"Hloubkoměry s úchylkoměrem Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) – rozlišení (0,001; 0,005; 0,01)mm – rozlišení (0,001; 0,005; 0,01)mm – rozlišení (0,001; 0,005; 0,01)mm Vnitřní postup IW/KUM/14/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Hloubkoměry s úchylkoměrem"},{"_id":"73bb62ce9bdbfe8b7b8c4b99","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Głębokościomierze mikrometryczne","test_object_en":"Micrometer depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"0,8 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"1,3 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"2,6 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"3,3 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"3,9 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"0,8 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"1,3 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"2,6 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"3,3 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"3,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 0,8 µm\n50 mm do 100 mm CMC 1,3 µm\n100 mm do 150 mm CMC 1,9 µm\n150 mm do 200 mm CMC 2,6 µm\n200 mm do 250 mm CMC 3,3 µm\n250 mm do 300 mm CMC 3,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/02/02","norm_bases":["IW/KUM/02/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze mikrometryczne Wzorcowanie — Długość\nZakres:\n0 mm do 50 mm CMC 0,8 µm\n50 mm do 100 mm CMC 1,3 µm\n100 mm do 150 mm CMC 1,9 µm\n150 mm do 200 mm CMC 2,6 µm\n200 mm do 250 mm CMC 3,3 µm\n250 mm do 300 mm CMC 3,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/02/02 Glebokosciomierze mikrometryczne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 50 mm CMC 0,8 µm\n50 mm do 100 mm CMC 1,3 µm\n100 mm do 150 mm CMC 1,9 µm\n150 mm do 200 mm CMC 2,6 µm\n200 mm do 250 mm CMC 3,3 µm\n250 mm do 300 mm CMC 3,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/02/02","search_en":"Micrometer depth gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/02/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":31,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/02/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"0,8 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"1,3 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"2,6 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"3,3 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"3,9 µm"}],"reference_de":"Internes Verfahren IW/KUM/02/02","regulatory_area_de":"Länge","search_de":"Mikrometer-Tiefenmessgeräte Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/02/02","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Mikrometer-Tiefenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"0,8 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"1,3 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"2,6 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"3,3 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"3,9 µm"}],"reference_zh":"内部程序 IW/KUM/02/02","regulatory_area_zh":"长度","search_zh":"深度千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/02/02","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"深度千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"0,8 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"1,3 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"2,6 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"3,3 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"3,9 µm"}],"reference_cs":"Vnitřní postup IW/KUM/02/02","regulatory_area_cs":"Délka","search_cs":"Mikrometrické hloubkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/02/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometrické hloubkoměry"},{"_id":"3b51d2c84f1fdbe3e780037b","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Głębokościomierze suwmiarkowe","test_object_en":"Vernier depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 150 mm","cmc":"8 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"16 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"18 µm"}],"parameters_en":[{"name":"","range":"0 mm do 150 mm","cmc":"8 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"16 µm"},{"name":"","range":"0 mm to 600 mm","cmc":"18 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 8 µm\n0 mm do 300 mm CMC 11 µm\n0 mm do 500 mm CMC 16 µm\n0 mm do 600 mm CMC 18 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/01/01","norm_bases":["IW/KUM/01/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze suwmiarkowe Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 8 µm\n0 mm do 300 mm CMC 11 µm\n0 mm do 500 mm CMC 16 µm\n0 mm do 600 mm CMC 18 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/01/01 Glebokosciomierze suwmiarkowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 150 mm CMC 8 µm\n0 mm do 300 mm CMC 11 µm\n0 mm do 500 mm CMC 16 µm\n0 mm do 600 mm CMC 18 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/01/01","search_en":"Vernier depth gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/01/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":32,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/01/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 150 mm","cmc":"8 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"16 µm"},{"name":"","range":"0 mm bis 600 mm","cmc":"18 µm"}],"reference_de":"Internes Verfahren IW/KUM/01/01","regulatory_area_de":"Länge","search_de":"Tiefenmessschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/01/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Tiefenmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 150 mm","cmc":"8 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"16 µm"},{"name":"","range":"0 mm 至 600 mm","cmc":"18 µm"}],"reference_zh":"内部程序 IW/KUM/01/01","regulatory_area_zh":"长度","search_zh":"深度游标卡尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/01/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"深度游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 150 mm","cmc":"8 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"16 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"18 µm"}],"reference_cs":"Vnitřní postup IW/KUM/01/01","regulatory_area_cs":"Délka","search_cs":"Posuvné hloubkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/01/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvné hloubkoměry"},{"_id":"ef1393953eac78e7f1e0b6b8","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Grubościomierze ultradźwiękowe","test_object_en":"Ultrasonic thickness gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- rozdzielczość 0,001 mm","range":"0,5 mm do 50 mm","cmc":"4 µm"},{"name":"- rozdzielczość 0,001 mm","range":"50 mm do 100 mm","cmc":"5 µm"},{"name":"- rozdzielczość 0,001 mm","range":"100 mm do 125 mm","cmc":"7 µm"},{"name":"- rozdzielczość 0,01 mm","range":"0,5 mm do 50 mm","cmc":"7 µm"},{"name":"- rozdzielczość 0,01 mm","range":"50 mm do 100 mm","cmc":"9 µm"},{"name":"- rozdzielczość 0,01 mm","range":"100 mm do 125 mm","cmc":"10 µm"},{"name":"- rozdzielczość 0,1 mm","range":"0,5 mm do 125 mm","cmc":"64 µm"}],"parameters_en":[{"name":"- resolution 0,001 mm","range":"0,5 mm to 50 mm","cmc":"4 µm"},{"name":"- resolution 0,001 mm","range":"50 mm to 100 mm","cmc":"5 µm"},{"name":"- resolution 0,001 mm","range":"100 mm to 125 mm","cmc":"7 µm"},{"name":"- resolution 0,01 mm","range":"0,5 mm to 50 mm","cmc":"7 µm"},{"name":"- resolution 0,01 mm","range":"50 mm to 100 mm","cmc":"9 µm"},{"name":"- resolution 0,01 mm","range":"100 mm to 125 mm","cmc":"10 µm"},{"name":"- resolution 0,1 mm","range":"0,5 mm to 125 mm","cmc":"64 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem wzorców schodkowych do grubościomierzy ultradźwiękowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using step standards for ultrasonic thickness gauges; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem wzorców schodkowych do grubościomierzy ultradźwiękowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using step standards for ultrasonic thickness gauges","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- rozdzielczość 0,001 mm 0,5 mm do 50 mm CMC 4 µm\n- rozdzielczość 0,001 mm 50 mm do 100 mm CMC 5 µm\n- rozdzielczość 0,001 mm 100 mm do 125 mm CMC 7 µm\n- rozdzielczość 0,01 mm 0,5 mm do 50 mm CMC 7 µm\n- rozdzielczość 0,01 mm 50 mm do 100 mm CMC 9 µm\n- rozdzielczość 0,01 mm 100 mm do 125 mm CMC 10 µm\n- rozdzielczość 0,1 mm 0,5 mm do 125 mm CMC 64 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem wzorców schodkowych do grubościomierzy ultradźwiękowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/24/02","norm_bases":["IW/KUM/24/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Grubościomierze ultradźwiękowe Wzorcowanie — Długość\nZakres:\n- rozdzielczość 0,001 mm 0,5 mm do 50 mm CMC 4 µm\n- rozdzielczość 0,001 mm 50 mm do 100 mm CMC 5 µm\n- rozdzielczość 0,001 mm 100 mm do 125 mm CMC 7 µm\n- rozdzielczość 0,01 mm 0,5 mm do 50 mm CMC 7 µm\n- rozdzielczość 0,01 mm 50 mm do 100 mm CMC 9 µm\n- rozdzielczość 0,01 mm 100 mm do 125 mm CMC 10 µm\n- rozdzielczość 0,1 mm 0,5 mm do 125 mm CMC 64 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem wzorców schodkowych do grubościomierzy ultradźwiękowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/24/02 Grubosciomierze ultradzwiekowe Wzorcowanie — Dlugosc\nZakres:\n- rozdzielczosc 0,001 mm 0,5 mm do 50 mm CMC 4 µm\n- rozdzielczosc 0,001 mm 50 mm do 100 mm CMC 5 µm\n- rozdzielczosc 0,001 mm 100 mm do 125 mm CMC 7 µm\n- rozdzielczosc 0,01 mm 0,5 mm do 50 mm CMC 7 µm\n- rozdzielczosc 0,01 mm 50 mm do 100 mm CMC 9 µm\n- rozdzielczosc 0,01 mm 100 mm do 125 mm CMC 10 µm\n- rozdzielczosc 0,1 mm 0,5 mm do 125 mm CMC 64 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem wzorcow schodkowych do grubosciomierzy ultradzwiekowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/24/02","search_en":"Ultrasonic thickness gauges Calibration — Length Internal procedure; Direct method using step standards for ultrasonic thickness gauges; At permanent location (S) Length Internal procedure Direct method using step standards for ultrasonic thickness gauges At permanent location (S) - resolution 0,001 mm - resolution 0,001 mm - resolution 0,001 mm - resolution 0,01 mm - resolution 0,01 mm - resolution 0,01 mm - resolution 0,1 mm Internal procedure IW/KUM/24/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":33,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/24/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Auflösung 0,001 mm","range":"0,5 mm to 50 mm","cmc":"4 µm"},{"name":"- Auflösung 0,001 mm","range":"50 mm to 100 mm","cmc":"5 µm"},{"name":"- Auflösung 0,001 mm","range":"100 mm bis 125 mm","cmc":"7 µm"},{"name":"- Auflösung 0,01 mm","range":"0,5 mm to 50 mm","cmc":"7 µm"},{"name":"- Auflösung 0,01 mm","range":"50 mm to 100 mm","cmc":"9 µm"},{"name":"- Auflösung 0,01 mm","range":"100 mm bis 125 mm","cmc":"10 µm"},{"name":"- Auflösung 0,1 mm","range":"0,5 mm to 125 mm","cmc":"64 µm"}],"reference_de":"Internes Verfahren IW/KUM/24/02","regulatory_area_de":"Länge","search_de":"Ultraschall-Dickenmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Stufennormalen für Ultraschall-Dickenmessgeräte; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Stufennormalen für Ultraschall-Dickenmessgeräte Am festen Standort (S) - Auflösung 0,001 mm - Auflösung 0,001 mm - Auflösung 0,001 mm - Auflösung 0,01 mm - Auflösung 0,01 mm - Auflösung 0,01 mm - Auflösung 0,1 mm Internes Verfahren IW/KUM/24/02","technique_de":"Internes Verfahren; Direktes Verfahren mit Stufennormalen für Ultraschall-Dickenmessgeräte; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Stufennormalen für Ultraschall-Dickenmessgeräte","Am festen Standort (S)"],"test_object_de":"Ultraschall-Dickenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 分辨力 0,001 mm","range":"0,5 mm to 50 mm","cmc":"4 µm"},{"name":"- 分辨力 0,001 mm","range":"50 mm to 100 mm","cmc":"5 µm"},{"name":"- 分辨力 0,001 mm","range":"100 mm 至 125 mm","cmc":"7 µm"},{"name":"- 分辨力 0,01 mm","range":"0,5 mm to 50 mm","cmc":"7 µm"},{"name":"- 分辨力 0,01 mm","range":"50 mm to 100 mm","cmc":"9 µm"},{"name":"- 分辨力 0,01 mm","range":"100 mm 至 125 mm","cmc":"10 µm"},{"name":"- 分辨力 0,1 mm","range":"0,5 mm to 125 mm","cmc":"64 µm"}],"reference_zh":"内部程序 IW/KUM/24/02","regulatory_area_zh":"长度","search_zh":"超声波测厚仪 校准 — 长度 内部程序；使用超声波测厚仪阶梯标准块的直接法；在固定地点 (S) 长度 内部程序 使用超声波测厚仪阶梯标准块的直接法 在固定地点 (S) - 分辨力 0,001 mm - 分辨力 0,001 mm - 分辨力 0,001 mm - 分辨力 0,01 mm - 分辨力 0,01 mm - 分辨力 0,01 mm - 分辨力 0,1 mm 内部程序 IW/KUM/24/02","technique_zh":"内部程序；使用超声波测厚仪阶梯标准块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用超声波测厚仪阶梯标准块的直接法","在固定地点 (S)"],"test_object_zh":"超声波测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- rozlišení 0,001 mm","range":"0,5 mm to 50 mm","cmc":"4 µm"},{"name":"- rozlišení 0,001 mm","range":"50 mm to 100 mm","cmc":"5 µm"},{"name":"- rozlišení 0,001 mm","range":"100 mm do 125 mm","cmc":"7 µm"},{"name":"- rozlišení 0,01 mm","range":"0,5 mm to 50 mm","cmc":"7 µm"},{"name":"- rozlišení 0,01 mm","range":"50 mm to 100 mm","cmc":"9 µm"},{"name":"- rozlišení 0,01 mm","range":"100 mm do 125 mm","cmc":"10 µm"},{"name":"- rozlišení 0,1 mm","range":"0,5 mm to 125 mm","cmc":"64 µm"}],"reference_cs":"Vnitřní postup IW/KUM/24/02","regulatory_area_cs":"Délka","search_cs":"Ultrazvukové tloušťkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím stupňových etalonů pro ultrazvukové tloušťkoměry; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím stupňových etalonů pro ultrazvukové tloušťkoměry Ve stálé lokalitě (S) - rozlišení 0,001 mm - rozlišení 0,001 mm - rozlišení 0,001 mm - rozlišení 0,01 mm - rozlišení 0,01 mm - rozlišení 0,01 mm - rozlišení 0,1 mm Vnitřní postup IW/KUM/24/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím stupňových etalonů pro ultrazvukové tloušťkoměry; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím stupňových etalonů pro ultrazvukové tloušťkoměry","Ve stálé lokalitě (S)"],"test_object_cs":"Ultrazvukové tloušťkoměry"},{"_id":"ee6f109dc75009b56d3201ae","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Głowice mikrometryczne","test_object_en":"Micrometer heads","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 15 mm","cmc":"0,7 µm"},{"name":"","range":"0 mm do 25 mm","cmc":"0,8 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"","range":"0 mm do 15 mm","cmc":"0,7 µm"},{"name":"","range":"0 mm to 25 mm","cmc":"0,8 µm"},{"name":"","range":"0 mm to 50 mm","cmc":"1,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 15 mm CMC 0,7 µm\n0 mm do 25 mm CMC 0,8 µm\n0 mm do 50 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/02/02","norm_bases":["IW/KUM/02/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głowice mikrometryczne Wzorcowanie — Długość\nZakres:\n0 mm do 15 mm CMC 0,7 µm\n0 mm do 25 mm CMC 0,8 µm\n0 mm do 50 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/02/02 Glowice mikrometryczne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 15 mm CMC 0,7 µm\n0 mm do 25 mm CMC 0,8 µm\n0 mm do 50 mm CMC 1,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/02/02","search_en":"Micrometer heads Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/02/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":34,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/02/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 15 mm","cmc":"0,7 µm"},{"name":"","range":"0 mm bis 25 mm","cmc":"0,8 µm"},{"name":"","range":"0 mm bis 50 mm","cmc":"1,0 µm"}],"reference_de":"Internes Verfahren IW/KUM/02/02","regulatory_area_de":"Länge","search_de":"Mikrometerköpfe Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/02/02","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Mikrometerköpfe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 15 mm","cmc":"0,7 µm"},{"name":"","range":"0 mm 至 25 mm","cmc":"0,8 µm"},{"name":"","range":"0 mm 至 50 mm","cmc":"1,0 µm"}],"reference_zh":"内部程序 IW/KUM/02/02","regulatory_area_zh":"长度","search_zh":"测微头 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/02/02","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"测微头","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 15 mm","cmc":"0,7 µm"},{"name":"","range":"0 mm do 25 mm","cmc":"0,8 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"1,0 µm"}],"reference_cs":"Vnitřní postup IW/KUM/02/02","regulatory_area_cs":"Délka","search_cs":"Mikrometrické hlavice Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/02/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometrické hlavice"},{"_id":"5ce35698593b07d143e7287e","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Grubościomierze czujnikowe","test_object_en":"Dial thickness gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– dz. element. (0,001; 0,002; 0,005) mm","range":"0 mm do 5 mm","cmc":"0,3 µm"},{"name":"– dz. element. 0,01 mm","range":"0 mm do 10 mm","cmc":"0,7 µm"},{"name":"– dz. element. 0,01 mm","range":"0 mm do 30 mm","cmc":"0,8 µm"},{"name":"– dz. element. 0,01 mm","range":"0 mm do 50 mm","cmc":"1,0 µm"},{"name":"– dz. element. 0,1 mm","range":"0 mm do 50 mm","cmc":"6 µm"}],"parameters_en":[{"name":"– scale int. (0,001; 0,002; 0,005) mm","range":"0 mm to 5 mm","cmc":"0,3 µm"},{"name":"– scale int. 0,01 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– scale int. 0,01 mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– scale int. 0,01 mm","range":"0 mm to 50 mm","cmc":"1,0 µm"},{"name":"– scale int. 0,1 mm","range":"0 mm to 50 mm","cmc":"6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– dz. element. (0,001; 0,002; 0,005) mm 0 mm do 5 mm CMC 0,3 µm\n– dz. element. 0,01 mm 0 mm do 10 mm CMC 0,7 µm\n– dz. element. 0,01 mm 0 mm do 30 mm CMC 0,8 µm\n– dz. element. 0,01 mm 0 mm do 50 mm CMC 1,0 µm\n– dz. element. 0,1 mm 0 mm do 50 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/14/02","norm_bases":["IW/KUM/14/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Grubościomierze czujnikowe Wzorcowanie — Długość\nZakres:\n– dz. element. (0,001; 0,002; 0,005) mm 0 mm do 5 mm CMC 0,3 µm\n– dz. element. 0,01 mm 0 mm do 10 mm CMC 0,7 µm\n– dz. element. 0,01 mm 0 mm do 30 mm CMC 0,8 µm\n– dz. element. 0,01 mm 0 mm do 50 mm CMC 1,0 µm\n– dz. element. 0,1 mm 0 mm do 50 mm CMC 6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/14/02 Grubosciomierze czujnikowe Wzorcowanie — Dlugosc\nZakres:\n– dz. element. (0,001; 0,002; 0,005) mm 0 mm do 5 mm CMC 0,3 µm\n– dz. element. 0,01 mm 0 mm do 10 mm CMC 0,7 µm\n– dz. element. 0,01 mm 0 mm do 30 mm CMC 0,8 µm\n– dz. element. 0,01 mm 0 mm do 50 mm CMC 1,0 µm\n– dz. element. 0,1 mm 0 mm do 50 mm CMC 6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/14/02","search_en":"Dial thickness gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) – scale int. (0,001; 0,002; 0,005) mm – scale int. 0,01 mm – scale int. 0,01 mm – scale int. 0,01 mm – scale int. 0,1 mm Internal procedure IW/KUM/14/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":35,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/14/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Skalenteilungswert (0,001; 0,002; 0,005) mm","range":"0 mm to 5 mm","cmc":"0,3 µm"},{"name":"– Skalenteilungswert 0,01 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– Skalenteilungswert 0,01 mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– Skalenteilungswert 0,01 mm","range":"0 mm bis 50 mm","cmc":"1,0 µm"},{"name":"– Skalenteilungswert 0,1 mm","range":"0 mm bis 50 mm","cmc":"6 µm"}],"reference_de":"Internes Verfahren IW/KUM/14/02","regulatory_area_de":"Länge","search_de":"Dickenmessgeräte mit Messuhr Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) – Skalenteilungswert (0,001; 0,002; 0,005) mm – Skalenteilungswert 0,01 mm – Skalenteilungswert 0,01 mm – Skalenteilungswert 0,01 mm – Skalenteilungswert 0,1 mm Internes Verfahren IW/KUM/14/02","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Dickenmessgeräte mit Messuhr","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 分度值 (0,001; 0,002; 0,005) mm","range":"0 mm to 5 mm","cmc":"0,3 µm"},{"name":"– 分度值 0,01 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– 分度值 0,01 mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– 分度值 0,01 mm","range":"0 mm 至 50 mm","cmc":"1,0 µm"},{"name":"– 分度值 0,1 mm","range":"0 mm 至 50 mm","cmc":"6 µm"}],"reference_zh":"内部程序 IW/KUM/14/02","regulatory_area_zh":"长度","search_zh":"指示表式测厚仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) – 分度值 (0,001; 0,002; 0,005) mm – 分度值 0,01 mm – 分度值 0,01 mm – 分度值 0,01 mm – 分度值 0,1 mm 内部程序 IW/KUM/14/02","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"指示表式测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– hodnota dílku (0,001; 0,002; 0,005) mm","range":"0 mm to 5 mm","cmc":"0,3 µm"},{"name":"– hodnota dílku 0,01 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– hodnota dílku 0,01 mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– hodnota dílku 0,01 mm","range":"0 mm do 50 mm","cmc":"1,0 µm"},{"name":"– hodnota dílku 0,1 mm","range":"0 mm do 50 mm","cmc":"6 µm"}],"reference_cs":"Vnitřní postup IW/KUM/14/02","regulatory_area_cs":"Délka","search_cs":"Úchylkoměrné tloušťkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) – hodnota dílku (0,001; 0,002; 0,005) mm – hodnota dílku 0,01 mm – hodnota dílku 0,01 mm – hodnota dílku 0,01 mm – hodnota dílku 0,1 mm Vnitřní postup IW/KUM/14/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Úchylkoměrné tloušťkoměry"},{"_id":"f0d13288825f19463593edd8","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Grubościomierze czujnikowe","test_object_en":"Dial thickness gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– rozdzielczość (0,001; 0,005; 0,01)mm","range":"0 mm do 10 mm","cmc":"0,7 µm"},{"name":"– rozdzielczość (0,001; 0,005; 0,01)mm","range":"0 mm do 30 mm","cmc":"0,8 µm"},{"name":"– rozdzielczość (0,001; 0,005; 0,01)mm","range":"0 mm do 50 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"– resolution (0,001; 0,005; 0,01)mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– resolution (0,001; 0,005; 0,01)mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– resolution (0,001; 0,005; 0,01)mm","range":"0 mm to 50 mm","cmc":"1,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 10 mm CMC 0,7 µm\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 30 mm CMC 0,8 µm\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 50 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/14/02","norm_bases":["IW/KUM/14/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Grubościomierze czujnikowe Wzorcowanie — Długość\nZakres:\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 10 mm CMC 0,7 µm\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 30 mm CMC 0,8 µm\n– rozdzielczość (0,001; 0,005; 0,01)mm 0 mm do 50 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/14/02 Grubosciomierze czujnikowe Wzorcowanie — Dlugosc\nZakres:\n– rozdzielczosc (0,001; 0,005; 0,01)mm 0 mm do 10 mm CMC 0,7 µm\n– rozdzielczosc (0,001; 0,005; 0,01)mm 0 mm do 30 mm CMC 0,8 µm\n– rozdzielczosc (0,001; 0,005; 0,01)mm 0 mm do 50 mm CMC 1,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/14/02","search_en":"Dial thickness gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) – resolution (0,001; 0,005; 0,01)mm – resolution (0,001; 0,005; 0,01)mm – resolution (0,001; 0,005; 0,01)mm Internal procedure IW/KUM/14/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":36,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/14/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Auflösung (0,001; 0,005; 0,01)mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– Auflösung (0,001; 0,005; 0,01)mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– Auflösung (0,001; 0,005; 0,01)mm","range":"0 mm bis 50 mm","cmc":"1,0 µm"}],"reference_de":"Internes Verfahren IW/KUM/14/02","regulatory_area_de":"Länge","search_de":"Dickenmessgeräte mit Messuhr Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) – Auflösung (0,001; 0,005; 0,01)mm – Auflösung (0,001; 0,005; 0,01)mm – Auflösung (0,001; 0,005; 0,01)mm Internes Verfahren IW/KUM/14/02","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Dickenmessgeräte mit Messuhr","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 分辨力 (0,001; 0,005; 0,01)mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– 分辨力 (0,001; 0,005; 0,01)mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– 分辨力 (0,001; 0,005; 0,01)mm","range":"0 mm 至 50 mm","cmc":"1,0 µm"}],"reference_zh":"内部程序 IW/KUM/14/02","regulatory_area_zh":"长度","search_zh":"指示表式测厚仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) – 分辨力 (0,001; 0,005; 0,01)mm – 分辨力 (0,001; 0,005; 0,01)mm – 分辨力 (0,001; 0,005; 0,01)mm 内部程序 IW/KUM/14/02","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"指示表式测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– rozlišení (0,001; 0,005; 0,01)mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"– rozlišení (0,001; 0,005; 0,01)mm","range":"0 mm to 30 mm","cmc":"0,8 µm"},{"name":"– rozlišení (0,001; 0,005; 0,01)mm","range":"0 mm do 50 mm","cmc":"1,0 µm"}],"reference_cs":"Vnitřní postup IW/KUM/14/02","regulatory_area_cs":"Délka","search_cs":"Úchylkoměrné tloušťkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) – rozlišení (0,001; 0,005; 0,01)mm – rozlišení (0,001; 0,005; 0,01)mm – rozlišení (0,001; 0,005; 0,01)mm Vnitřní postup IW/KUM/14/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Úchylkoměrné tloušťkoměry"},{"_id":"8651320a073740d7f27c0905","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Macki pomiarowe zewnętrzne\nMacki pomiarowe wewnętrzne","test_object_en":"External measuring calipers\nInternal measuring calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"Macki pomiarowe zewnętrzne","range":"0 mm do 10 mm","cmc":"0,5 µm"},{"name":"Macki pomiarowe zewnętrzne","range":"0 mm do 20 mm","cmc":"0,7 µm"},{"name":"Macki pomiarowe zewnętrzne","range":"0 mm do 40 mm","cmc":"1,2 µm"},{"name":"Macki pomiarowe zewnętrzne","range":"0 mm do 60 mm","cmc":"1,7 µm"},{"name":"Macki pomiarowe zewnętrzne","range":"0 mm do 100 mm","cmc":"2,8 µm"},{"name":"Macki pomiarowe wewnętrzne","range":"2,5 mm do 12,5 mm","cmc":"0,6 µm"},{"name":"Macki pomiarowe wewnętrzne","range":"10 mm do 22 mm","cmc":"0,8 µm"},{"name":"Macki pomiarowe wewnętrzne","range":"10 mm do 35 mm","cmc":"1,1 µm"},{"name":"Macki pomiarowe wewnętrzne","range":"30 mm do 55 mm","cmc":"1,6 µm"},{"name":"Macki pomiarowe wewnętrzne","range":"40 mm do 90 mm","cmc":"2,5 µm"},{"name":"Macki pomiarowe wewnętrzne","range":"70 mm do 120 mm","cmc":"3,3 µm"},{"name":"Macki pomiarowe wewnętrzne","range":"90 mm do 140 mm","cmc":"3,9 µm"},{"name":"Macki pomiarowe wewnętrzne","range":"130 mm do 180 mm","cmc":"4,9 µm"}],"parameters_en":[{"name":"External measuring calipers","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"External measuring calipers","range":"0 mm to 20 mm","cmc":"0,7 µm"},{"name":"External measuring calipers","range":"0 mm to 40 mm","cmc":"1,2 µm"},{"name":"External measuring calipers","range":"0 mm to 60 mm","cmc":"1,7 µm"},{"name":"External measuring calipers","range":"0 mm to 100 mm","cmc":"2,8 µm"},{"name":"Internal measuring calipers","range":"2,5 mm to 12,5 mm","cmc":"0,6 µm"},{"name":"Internal measuring calipers","range":"10 mm to 22 mm","cmc":"0,8 µm"},{"name":"Internal measuring calipers","range":"10 mm to 35 mm","cmc":"1,1 µm"},{"name":"Internal measuring calipers","range":"30 mm to 55 mm","cmc":"1,6 µm"},{"name":"Internal measuring calipers","range":"40 mm to 90 mm","cmc":"2,5 µm"},{"name":"Internal measuring calipers","range":"70 mm to 120 mm","cmc":"3,3 µm"},{"name":"Internal measuring calipers","range":"90 mm to 140 mm","cmc":"3,9 µm"},{"name":"Internal measuring calipers","range":"130 mm to 180 mm","cmc":"4,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\nMacki pomiarowe zewnętrzne 0 mm do 10 mm CMC 0,5 µm\nMacki pomiarowe zewnętrzne 0 mm do 20 mm CMC 0,7 µm\nMacki pomiarowe zewnętrzne 0 mm do 40 mm CMC 1,2 µm\nMacki pomiarowe zewnętrzne 0 mm do 60 mm CMC 1,7 µm\nMacki pomiarowe zewnętrzne 0 mm do 100 mm CMC 2,8 µm\nMacki pomiarowe wewnętrzne 2,5 mm do 12,5 mm CMC 0,6 µm\nMacki pomiarowe wewnętrzne 10 mm do 22 mm CMC 0,8 µm\nMacki pomiarowe wewnętrzne 10 mm do 35 mm CMC 1,1 µm\nMacki pomiarowe wewnętrzne 30 mm do 55 mm CMC 1,6 µm\nMacki pomiarowe wewnętrzne 40 mm do 90 mm CMC 2,5 µm\nMacki pomiarowe wewnętrzne 70 mm do 120 mm CMC 3,3 µm\nMacki pomiarowe wewnętrzne 90 mm do 140 mm CMC 3,9 µm\nMacki pomiarowe wewnętrzne 130 mm do 180 mm CMC 4,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/14/03","norm_bases":["IW/KUM/14/03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Macki pomiarowe zewnętrzne\nMacki pomiarowe wewnętrzne Wzorcowanie — Długość\nZakres:\nMacki pomiarowe zewnętrzne 0 mm do 10 mm CMC 0,5 µm\nMacki pomiarowe zewnętrzne 0 mm do 20 mm CMC 0,7 µm\nMacki pomiarowe zewnętrzne 0 mm do 40 mm CMC 1,2 µm\nMacki pomiarowe zewnętrzne 0 mm do 60 mm CMC 1,7 µm\nMacki pomiarowe zewnętrzne 0 mm do 100 mm CMC 2,8 µm\nMacki pomiarowe wewnętrzne 2,5 mm do 12,5 mm CMC 0,6 µm\nMacki pomiarowe wewnętrzne 10 mm do 22 mm CMC 0,8 µm\nMacki pomiarowe wewnętrzne 10 mm do 35 mm CMC 1,1 µm\nMacki pomiarowe wewnętrzne 30 mm do 55 mm CMC 1,6 µm\nMacki pomiarowe wewnętrzne 40 mm do 90 mm CMC 2,5 µm\nMacki pomiarowe wewnętrzne 70 mm do 120 mm CMC 3,3 µm\nMacki pomiarowe wewnętrzne 90 mm do 140 mm CMC 3,9 µm\nMacki pomiarowe wewnętrzne 130 mm do 180 mm CMC 4,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/14/03 Macki pomiarowe zewnetrzne\nMacki pomiarowe wewnetrzne Wzorcowanie — Dlugosc\nZakres:\nMacki pomiarowe zewnetrzne 0 mm do 10 mm CMC 0,5 µm\nMacki pomiarowe zewnetrzne 0 mm do 20 mm CMC 0,7 µm\nMacki pomiarowe zewnetrzne 0 mm do 40 mm CMC 1,2 µm\nMacki pomiarowe zewnetrzne 0 mm do 60 mm CMC 1,7 µm\nMacki pomiarowe zewnetrzne 0 mm do 100 mm CMC 2,8 µm\nMacki pomiarowe wewnetrzne 2,5 mm do 12,5 mm CMC 0,6 µm\nMacki pomiarowe wewnetrzne 10 mm do 22 mm CMC 0,8 µm\nMacki pomiarowe wewnetrzne 10 mm do 35 mm CMC 1,1 µm\nMacki pomiarowe wewnetrzne 30 mm do 55 mm CMC 1,6 µm\nMacki pomiarowe wewnetrzne 40 mm do 90 mm CMC 2,5 µm\nMacki pomiarowe wewnetrzne 70 mm do 120 mm CMC 3,3 µm\nMacki pomiarowe wewnetrzne 90 mm do 140 mm CMC 3,9 µm\nMacki pomiarowe wewnetrzne 130 mm do 180 mm CMC 4,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/14/03","search_en":"External measuring calipers Internal measuring calipers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) External measuring calipers External measuring calipers External measuring calipers External measuring calipers External measuring calipers Internal measuring calipers Internal measuring calipers Internal measuring calipers Internal measuring calipers Internal measuring calipers Internal measuring calipers Internal measuring calipers Internal measuring calipers Internal procedure IW/KUM/14/03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":37,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/14/03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Außentaster","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"Außentaster","range":"0 mm to 20 mm","cmc":"0,7 µm"},{"name":"Außentaster","range":"0 mm to 40 mm","cmc":"1,2 µm"},{"name":"Außentaster","range":"0 mm to 60 mm","cmc":"1,7 µm"},{"name":"Außentaster","range":"0 mm to 100 mm","cmc":"2,8 µm"},{"name":"Innentaster","range":"2,5 mm to 12,5 mm","cmc":"0,6 µm"},{"name":"Innentaster","range":"10 mm to 22 mm","cmc":"0,8 µm"},{"name":"Innentaster","range":"10 mm to 35 mm","cmc":"1,1 µm"},{"name":"Innentaster","range":"30 mm to 55 mm","cmc":"1,6 µm"},{"name":"Innentaster","range":"40 mm to 90 mm","cmc":"2,5 µm"},{"name":"Innentaster","range":"70 mm to 120 mm","cmc":"3,3 µm"},{"name":"Innentaster","range":"90 mm to 140 mm","cmc":"3,9 µm"},{"name":"Innentaster","range":"130 mm to 180 mm","cmc":"4,9 µm"}],"reference_de":"Internes Verfahren IW/KUM/14/03","regulatory_area_de":"Länge","search_de":"Außentaster Innentaster Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Außentaster Außentaster Außentaster Außentaster Außentaster Innentaster Innentaster Innentaster Innentaster Innentaster Innentaster Innentaster Innentaster Internes Verfahren IW/KUM/14/03","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Außentaster\nInnentaster","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"外卡钳","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"外卡钳","range":"0 mm to 20 mm","cmc":"0,7 µm"},{"name":"外卡钳","range":"0 mm to 40 mm","cmc":"1,2 µm"},{"name":"外卡钳","range":"0 mm to 60 mm","cmc":"1,7 µm"},{"name":"外卡钳","range":"0 mm to 100 mm","cmc":"2,8 µm"},{"name":"内卡钳","range":"2,5 mm to 12,5 mm","cmc":"0,6 µm"},{"name":"内卡钳","range":"10 mm to 22 mm","cmc":"0,8 µm"},{"name":"内卡钳","range":"10 mm to 35 mm","cmc":"1,1 µm"},{"name":"内卡钳","range":"30 mm to 55 mm","cmc":"1,6 µm"},{"name":"内卡钳","range":"40 mm to 90 mm","cmc":"2,5 µm"},{"name":"内卡钳","range":"70 mm to 120 mm","cmc":"3,3 µm"},{"name":"内卡钳","range":"90 mm to 140 mm","cmc":"3,9 µm"},{"name":"内卡钳","range":"130 mm to 180 mm","cmc":"4,9 µm"}],"reference_zh":"内部程序 IW/KUM/14/03","regulatory_area_zh":"长度","search_zh":"外卡钳 内卡钳 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 外卡钳 外卡钳 外卡钳 外卡钳 外卡钳 内卡钳 内卡钳 内卡钳 内卡钳 内卡钳 内卡钳 内卡钳 内卡钳 内部程序 IW/KUM/14/03","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"外卡钳\n内卡钳","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"Vnější odpichy","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"Vnější odpichy","range":"0 mm to 20 mm","cmc":"0,7 µm"},{"name":"Vnější odpichy","range":"0 mm to 40 mm","cmc":"1,2 µm"},{"name":"Vnější odpichy","range":"0 mm to 60 mm","cmc":"1,7 µm"},{"name":"Vnější odpichy","range":"0 mm to 100 mm","cmc":"2,8 µm"},{"name":"Vnitřní odpichy","range":"2,5 mm to 12,5 mm","cmc":"0,6 µm"},{"name":"Vnitřní odpichy","range":"10 mm to 22 mm","cmc":"0,8 µm"},{"name":"Vnitřní odpichy","range":"10 mm to 35 mm","cmc":"1,1 µm"},{"name":"Vnitřní odpichy","range":"30 mm to 55 mm","cmc":"1,6 µm"},{"name":"Vnitřní odpichy","range":"40 mm to 90 mm","cmc":"2,5 µm"},{"name":"Vnitřní odpichy","range":"70 mm to 120 mm","cmc":"3,3 µm"},{"name":"Vnitřní odpichy","range":"90 mm to 140 mm","cmc":"3,9 µm"},{"name":"Vnitřní odpichy","range":"130 mm to 180 mm","cmc":"4,9 µm"}],"reference_cs":"Vnitřní postup IW/KUM/14/03","regulatory_area_cs":"Délka","search_cs":"Vnější odpichy Vnitřní odpichy Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnější odpichy Vnější odpichy Vnější odpichy Vnější odpichy Vnější odpichy Vnitřní odpichy Vnitřní odpichy Vnitřní odpichy Vnitřní odpichy Vnitřní odpichy Vnitřní odpichy Vnitřní odpichy Vnitřní odpichy Vnitřní postup IW/KUM/14/03","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Vnější odpichy\nVnitřní odpichy"},{"_id":"36cd0b09bb58c85f2ef31446","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Mierniki do pomiaru grubości powłok","test_object_en":"Coating thickness meters","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 µm do 200 µm","cmc":"1,5 µm"},{"name":"","range":"200 µm do 500 µm","cmc":"1,7 µm"},{"name":"","range":"500 µm do 1000 µm","cmc":"2,0 µm"},{"name":"","range":"1000 µm do 1500 µm","cmc":"2,4 µm"},{"name":"","range":"1500 µm do 2000 µm","cmc":"2,9 µm"}],"parameters_en":[{"name":"","range":"0 µm to 200 µm","cmc":"1,5 µm"},{"name":"","range":"200 µm to 500 µm","cmc":"1,7 µm"},{"name":"","range":"500 µm to 1000 µm","cmc":"2,0 µm"},{"name":"","range":"1000 µm to 1500 µm","cmc":"2,4 µm"},{"name":"","range":"1500 µm to 2000 µm","cmc":"2,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem folii wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using reference foils; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem folii wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using reference foils","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 µm do 200 µm CMC 1,5 µm\n200 µm do 500 µm CMC 1,7 µm\n500 µm do 1000 µm CMC 2,0 µm\n1000 µm do 1500 µm CMC 2,4 µm\n1500 µm do 2000 µm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem folii wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/24/01","norm_bases":["IW/KUM/24/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki do pomiaru grubości powłok Wzorcowanie — Długość\nZakres:\n0 µm do 200 µm CMC 1,5 µm\n200 µm do 500 µm CMC 1,7 µm\n500 µm do 1000 µm CMC 2,0 µm\n1000 µm do 1500 µm CMC 2,4 µm\n1500 µm do 2000 µm CMC 2,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem folii wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/24/01 Mierniki do pomiaru grubosci powlok Wzorcowanie — Dlugosc\nZakres:\n0 µm do 200 µm CMC 1,5 µm\n200 µm do 500 µm CMC 1,7 µm\n500 µm do 1000 µm CMC 2,0 µm\n1000 µm do 1500 µm CMC 2,4 µm\n1500 µm do 2000 µm CMC 2,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem folii wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/24/01","search_en":"Coating thickness meters Calibration — Length Internal procedure; Direct method using reference foils; At permanent location (S) Length Internal procedure Direct method using reference foils At permanent location (S) Internal procedure IW/KUM/24/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":38,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/24/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 µm to 200 µm","cmc":"1,5 µm"},{"name":"","range":"200 µm to 500 µm","cmc":"1,7 µm"},{"name":"","range":"500 µm to 1000 µm","cmc":"2,0 µm"},{"name":"","range":"1000 µm to 1500 µm","cmc":"2,4 µm"},{"name":"","range":"1500 µm to 2000 µm","cmc":"2,9 µm"}],"reference_de":"Internes Verfahren IW/KUM/24/01","regulatory_area_de":"Länge","search_de":"Schichtdickenmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Referenzfolien; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Referenzfolien Am festen Standort (S) Internes Verfahren IW/KUM/24/01","technique_de":"Internes Verfahren; Direktes Verfahren mit Referenzfolien; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Referenzfolien","Am festen Standort (S)"],"test_object_de":"Schichtdickenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 µm to 200 µm","cmc":"1,5 µm"},{"name":"","range":"200 µm to 500 µm","cmc":"1,7 µm"},{"name":"","range":"500 µm to 1000 µm","cmc":"2,0 µm"},{"name":"","range":"1000 µm to 1500 µm","cmc":"2,4 µm"},{"name":"","range":"1500 µm to 2000 µm","cmc":"2,9 µm"}],"reference_zh":"内部程序 IW/KUM/24/01","regulatory_area_zh":"长度","search_zh":"涂层测厚仪 校准 — 长度 内部程序；使用标准箔片的直接法；在固定地点 (S) 长度 内部程序 使用标准箔片的直接法 在固定地点 (S) 内部程序 IW/KUM/24/01","technique_zh":"内部程序；使用标准箔片的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用标准箔片的直接法","在固定地点 (S)"],"test_object_zh":"涂层测厚仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 µm to 200 µm","cmc":"1,5 µm"},{"name":"","range":"200 µm to 500 µm","cmc":"1,7 µm"},{"name":"","range":"500 µm to 1000 µm","cmc":"2,0 µm"},{"name":"","range":"1000 µm to 1500 µm","cmc":"2,4 µm"},{"name":"","range":"1500 µm to 2000 µm","cmc":"2,9 µm"}],"reference_cs":"Vnitřní postup IW/KUM/24/01","regulatory_area_cs":"Délka","search_cs":"Měřidla tloušťky povlaků Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím etalonových fólií; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím etalonových fólií Ve stálé lokalitě (S) Vnitřní postup IW/KUM/24/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím etalonových fólií; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím etalonových fólií","Ve stálé lokalitě (S)"],"test_object_cs":"Měřidla tloušťky povlaků"},{"_id":"7ab40f35992a82158a7f0b9b","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Mikrometry laserowe skaningowe","test_object_en":"Laser scan micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,1 mm do 25 mm","cmc":"0,32 µm"}],"parameters_en":[{"name":"","range":"0,1 mm to 25 mm","cmc":"0,32 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem wałeczków pomiarowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using measuring rollers; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem wałeczków pomiarowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using measuring rollers","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,1 mm do 25 mm CMC 0,32 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem wałeczków pomiarowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/25/01","norm_bases":["IW/KUM/25/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry laserowe skaningowe Wzorcowanie — Długość\n0,1 mm do 25 mm CMC 0,32 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem wałeczków pomiarowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/25/01 Mikrometry laserowe skaningowe Wzorcowanie — Dlugosc\n0,1 mm do 25 mm CMC 0,32 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem waleczkow pomiarowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/25/01","search_en":"Laser scan micrometers Calibration — Length Internal procedure; Direct method using measuring rollers; At permanent location (S) Length Internal procedure Direct method using measuring rollers At permanent location (S) Internal procedure IW/KUM/25/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":39,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/25/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,1 mm to 25 mm","cmc":"0,32 µm"}],"reference_de":"Internes Verfahren IW/KUM/25/01","regulatory_area_de":"Länge","search_de":"Laser-Scan-Mikrometer Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Messrollen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Messrollen Am festen Standort (S) Internes Verfahren IW/KUM/25/01","technique_de":"Internes Verfahren; Direktes Verfahren mit Messrollen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Messrollen","Am festen Standort (S)"],"test_object_de":"Laser-Scan-Mikrometer","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,1 mm to 25 mm","cmc":"0,32 µm"}],"reference_zh":"内部程序 IW/KUM/25/01","regulatory_area_zh":"长度","search_zh":"激光扫描测径仪 校准 — 长度 内部程序；使用测量棒的直接法；在固定地点 (S) 长度 内部程序 使用测量棒的直接法 在固定地点 (S) 内部程序 IW/KUM/25/01","technique_zh":"内部程序；使用测量棒的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用测量棒的直接法","在固定地点 (S)"],"test_object_zh":"激光扫描测径仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,1 mm to 25 mm","cmc":"0,32 µm"}],"reference_cs":"Vnitřní postup IW/KUM/25/01","regulatory_area_cs":"Délka","search_cs":"Laserové skenovací mikrometry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím měřicích válečků; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím měřicích válečků Ve stálé lokalitě (S) Vnitřní postup IW/KUM/25/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím měřicích válečků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím měřicích válečků","Ve stálé lokalitě (S)"],"test_object_cs":"Laserové skenovací mikrometry"},{"_id":"bbb3447e59701e8038c9b7bb","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Mikrometry wewnętrzne","test_object_en":"Internal micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"5 mm do 30 mm","cmc":"1,0 µm"},{"name":"","range":"30 mm do 55 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,0 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"2,5 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,8 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,2 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,5 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,2 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,5 µm"}],"parameters_en":[{"name":"","range":"5 mm do 30 mm","cmc":"1,0 µm"},{"name":"","range":"30 mm do 55 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"2,0 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"2,5 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"2,8 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"3,2 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,5 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,2 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n5 mm do 30 mm CMC 1,0 µm\n30 mm do 55 mm CMC 1,2 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,0 µm\n125 mm do 150 mm CMC 2,5 µm\n150 mm do 175 mm CMC 2,8 µm\n175 mm do 200 mm CMC 3,2 µm\n200 mm do 225 mm CMC 3,5 µm\n225 mm do 250 mm CMC 3,8 µm\n250 mm do 275 mm CMC 4,2 µm\n275 mm do 300 mm CMC 4,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/02/01","norm_bases":["IW/KUM/02/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry wewnętrzne Wzorcowanie — Długość\nZakres:\n5 mm do 30 mm CMC 1,0 µm\n30 mm do 55 mm CMC 1,2 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,0 µm\n125 mm do 150 mm CMC 2,5 µm\n150 mm do 175 mm CMC 2,8 µm\n175 mm do 200 mm CMC 3,2 µm\n200 mm do 225 mm CMC 3,5 µm\n225 mm do 250 mm CMC 3,8 µm\n250 mm do 275 mm CMC 4,2 µm\n275 mm do 300 mm CMC 4,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/02/01 Mikrometry wewnetrzne Wzorcowanie — Dlugosc\nZakres:\n5 mm do 30 mm CMC 1,0 µm\n30 mm do 55 mm CMC 1,2 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,0 µm\n125 mm do 150 mm CMC 2,5 µm\n150 mm do 175 mm CMC 2,8 µm\n175 mm do 200 mm CMC 3,2 µm\n200 mm do 225 mm CMC 3,5 µm\n225 mm do 250 mm CMC 3,8 µm\n250 mm do 275 mm CMC 4,2 µm\n275 mm do 300 mm CMC 4,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/02/01","search_en":"Internal micrometers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/02/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":40,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/02/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"5 mm do 30 mm","cmc":"1,0 µm"},{"name":"","range":"30 mm do 55 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"2,0 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"2,5 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"2,8 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"3,2 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,5 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,2 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,5 µm"}],"reference_de":"Internes Verfahren IW/KUM/02/01","regulatory_area_de":"Länge","search_de":"Innenmessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/02/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Innenmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"5 mm do 30 mm","cmc":"1,0 µm"},{"name":"","range":"30 mm do 55 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"2,0 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"2,5 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"2,8 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"3,2 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,5 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,2 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,5 µm"}],"reference_zh":"内部程序 IW/KUM/02/01","regulatory_area_zh":"长度","search_zh":"内径千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/02/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"内径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"5 mm do 30 mm","cmc":"1,0 µm"},{"name":"","range":"30 mm do 55 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,0 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"2,5 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,8 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,2 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,5 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,8 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,2 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,5 µm"}],"reference_cs":"Vnitřní postup IW/KUM/02/01","regulatory_area_cs":"Délka","search_cs":"Vnitřní mikrometry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/02/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Vnitřní mikrometry"},{"_id":"7c1ebfb693da323fa3d494de","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Mikrometry z wbudowanym czujnikiem","test_object_en":"Micrometers with built-in dial indicator","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– zespół czujnikowy","range":"-140 µm do 140 µm","cmc":"0,3 µm"},{"name":"– zespół mikrometryczny","range":"0 mm do 25 mm","cmc":"0,8 µm"},{"name":"– zespół mikrometryczny","range":"25 mm do 50 mm","cmc":"1,0 µm"},{"name":"– zespół mikrometryczny","range":"50 mm do 75 mm","cmc":"1,3 µm"},{"name":"– zespół mikrometryczny","range":"75 mm do 100 mm","cmc":"1,6 µm"},{"name":"– zespół mikrometryczny","range":"100 mm do 125 mm","cmc":"1,9 µm"},{"name":"– zespół mikrometryczny","range":"125 mm do 150 mm","cmc":"2,3 µm"}],"parameters_en":[{"name":"– indicator unit","range":"-140 µm to 140 µm","cmc":"0,3 µm"},{"name":"– micrometer unit","range":"0 mm to 25 mm","cmc":"0,8 µm"},{"name":"– micrometer unit","range":"25 mm to 50 mm","cmc":"1,0 µm"},{"name":"– micrometer unit","range":"50 mm to 75 mm","cmc":"1,3 µm"},{"name":"– micrometer unit","range":"75 mm to 100 mm","cmc":"1,6 µm"},{"name":"– micrometer unit","range":"100 mm to 125 mm","cmc":"1,9 µm"},{"name":"– micrometer unit","range":"125 mm to 150 mm","cmc":"2,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– zespół czujnikowy -140 µm do 140 µm CMC 0,3 µm\n– zespół mikrometryczny 0 mm do 25 mm CMC 0,8 µm\n– zespół mikrometryczny 25 mm do 50 mm CMC 1,0 µm\n– zespół mikrometryczny 50 mm do 75 mm CMC 1,3 µm\n– zespół mikrometryczny 75 mm do 100 mm CMC 1,6 µm\n– zespół mikrometryczny 100 mm do 125 mm CMC 1,9 µm\n– zespół mikrometryczny 125 mm do 150 mm CMC 2,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/02/03","norm_bases":["IW/KUM/02/03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry z wbudowanym czujnikiem Wzorcowanie — Długość\nZakres:\n– zespół czujnikowy -140 µm do 140 µm CMC 0,3 µm\n– zespół mikrometryczny 0 mm do 25 mm CMC 0,8 µm\n– zespół mikrometryczny 25 mm do 50 mm CMC 1,0 µm\n– zespół mikrometryczny 50 mm do 75 mm CMC 1,3 µm\n– zespół mikrometryczny 75 mm do 100 mm CMC 1,6 µm\n– zespół mikrometryczny 100 mm do 125 mm CMC 1,9 µm\n– zespół mikrometryczny 125 mm do 150 mm CMC 2,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/02/03 Mikrometry z wbudowanym czujnikiem Wzorcowanie — Dlugosc\nZakres:\n– zespol czujnikowy -140 µm do 140 µm CMC 0,3 µm\n– zespol mikrometryczny 0 mm do 25 mm CMC 0,8 µm\n– zespol mikrometryczny 25 mm do 50 mm CMC 1,0 µm\n– zespol mikrometryczny 50 mm do 75 mm CMC 1,3 µm\n– zespol mikrometryczny 75 mm do 100 mm CMC 1,6 µm\n– zespol mikrometryczny 100 mm do 125 mm CMC 1,9 µm\n– zespol mikrometryczny 125 mm do 150 mm CMC 2,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/02/03","search_en":"Micrometers with built-in dial indicator Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) – indicator unit – micrometer unit – micrometer unit – micrometer unit – micrometer unit – micrometer unit – micrometer unit Internal procedure IW/KUM/02/03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":41,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/02/03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Messuhreinheit","range":"-140 µm to 140 µm","cmc":"0,3 µm"},{"name":"– Mikrometereinheit","range":"0 mm bis 25 mm","cmc":"0,8 µm"},{"name":"– Mikrometereinheit","range":"25 mm bis 50 mm","cmc":"1,0 µm"},{"name":"– Mikrometereinheit","range":"50 mm bis 75 mm","cmc":"1,3 µm"},{"name":"– Mikrometereinheit","range":"75 mm bis 100 mm","cmc":"1,6 µm"},{"name":"– Mikrometereinheit","range":"100 mm bis 125 mm","cmc":"1,9 µm"},{"name":"– Mikrometereinheit","range":"125 mm bis 150 mm","cmc":"2,3 µm"}],"reference_de":"Internes Verfahren IW/KUM/02/03","regulatory_area_de":"Länge","search_de":"Feinzeigermessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) – Messuhreinheit – Mikrometereinheit – Mikrometereinheit – Mikrometereinheit – Mikrometereinheit – Mikrometereinheit – Mikrometereinheit Internes Verfahren IW/KUM/02/03","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Feinzeigermessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 指示表单元","range":"-140 µm to 140 µm","cmc":"0,3 µm"},{"name":"– 千分尺单元","range":"0 mm 至 25 mm","cmc":"0,8 µm"},{"name":"– 千分尺单元","range":"25 mm 至 50 mm","cmc":"1,0 µm"},{"name":"– 千分尺单元","range":"50 mm 至 75 mm","cmc":"1,3 µm"},{"name":"– 千分尺单元","range":"75 mm 至 100 mm","cmc":"1,6 µm"},{"name":"– 千分尺单元","range":"100 mm 至 125 mm","cmc":"1,9 µm"},{"name":"– 千分尺单元","range":"125 mm 至 150 mm","cmc":"2,3 µm"}],"reference_zh":"内部程序 IW/KUM/02/03","regulatory_area_zh":"长度","search_zh":"带表千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) – 指示表单元 – 千分尺单元 – 千分尺单元 – 千分尺单元 – 千分尺单元 – 千分尺单元 – 千分尺单元 内部程序 IW/KUM/02/03","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"带表千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– úchylkoměrová jednotka","range":"-140 µm to 140 µm","cmc":"0,3 µm"},{"name":"– mikrometrická jednotka","range":"0 mm do 25 mm","cmc":"0,8 µm"},{"name":"– mikrometrická jednotka","range":"25 mm do 50 mm","cmc":"1,0 µm"},{"name":"– mikrometrická jednotka","range":"50 mm do 75 mm","cmc":"1,3 µm"},{"name":"– mikrometrická jednotka","range":"75 mm do 100 mm","cmc":"1,6 µm"},{"name":"– mikrometrická jednotka","range":"100 mm do 125 mm","cmc":"1,9 µm"},{"name":"– mikrometrická jednotka","range":"125 mm do 150 mm","cmc":"2,3 µm"}],"reference_cs":"Vnitřní postup IW/KUM/02/03","regulatory_area_cs":"Délka","search_cs":"Mikrometry s vestavěným úchylkoměrem Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) – úchylkoměrová jednotka – mikrometrická jednotka – mikrometrická jednotka – mikrometrická jednotka – mikrometrická jednotka – mikrometrická jednotka – mikrometrická jednotka Vnitřní postup IW/KUM/02/03","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometry s vestavěným úchylkoměrem"},{"_id":"d94a6ca327e13bed7df96d7c","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Mikrometry zewnętrzne","test_object_en":"External micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,1 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,3 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,7 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,0 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,1 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,0 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 400 mm","cmc":"4,7 µm"},{"name":"","range":"400 mm do 500 mm","cmc":"6,1 µm"},{"name":"","range":"500 mm do 600 mm","cmc":"7,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"1,1 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"1,3 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"1,7 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"2,0 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"3,1 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,0 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 400 mm","cmc":"4,7 µm"},{"name":"","range":"400 mm do 500 mm","cmc":"6,1 µm"},{"name":"","range":"500 mm do 600 mm","cmc":"7,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 0,9 µm\n25 mm do 50 mm CMC 1,1 µm\n50 mm do 75 mm CMC 1,3 µm\n75 mm do 100 mm CMC 1,7 µm\n100 mm do 125 mm CMC 2,0 µm\n125 mm do 150 mm CMC 2,4 µm\n150 mm do 175 mm CMC 2,7 µm\n175 mm do 200 mm CMC 3,1 µm\n200 mm do 225 mm CMC 3,4 µm\n225 mm do 250 mm CMC 3,7 µm\n250 mm do 275 mm CMC 4,0 µm\n275 mm do 300 mm CMC 4,4 µm\n300 mm do 400 mm CMC 4,7 µm\n400 mm do 500 mm CMC 6,1 µm\n500 mm do 600 mm CMC 7,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/02/01","norm_bases":["IW/KUM/02/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry zewnętrzne Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 0,9 µm\n25 mm do 50 mm CMC 1,1 µm\n50 mm do 75 mm CMC 1,3 µm\n75 mm do 100 mm CMC 1,7 µm\n100 mm do 125 mm CMC 2,0 µm\n125 mm do 150 mm CMC 2,4 µm\n150 mm do 175 mm CMC 2,7 µm\n175 mm do 200 mm CMC 3,1 µm\n200 mm do 225 mm CMC 3,4 µm\n225 mm do 250 mm CMC 3,7 µm\n250 mm do 275 mm CMC 4,0 µm\n275 mm do 300 mm CMC 4,4 µm\n300 mm do 400 mm CMC 4,7 µm\n400 mm do 500 mm CMC 6,1 µm\n500 mm do 600 mm CMC 7,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/02/01 Mikrometry zewnetrzne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 25 mm CMC 0,9 µm\n25 mm do 50 mm CMC 1,1 µm\n50 mm do 75 mm CMC 1,3 µm\n75 mm do 100 mm CMC 1,7 µm\n100 mm do 125 mm CMC 2,0 µm\n125 mm do 150 mm CMC 2,4 µm\n150 mm do 175 mm CMC 2,7 µm\n175 mm do 200 mm CMC 3,1 µm\n200 mm do 225 mm CMC 3,4 µm\n225 mm do 250 mm CMC 3,7 µm\n250 mm do 275 mm CMC 4,0 µm\n275 mm do 300 mm CMC 4,4 µm\n300 mm do 400 mm CMC 4,7 µm\n400 mm do 500 mm CMC 6,1 µm\n500 mm do 600 mm CMC 7,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/02/01","search_en":"External micrometers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/02/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":42,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/02/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"1,1 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"1,3 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"1,7 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"2,0 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"3,1 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,0 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 400 mm","cmc":"4,7 µm"},{"name":"","range":"400 mm do 500 mm","cmc":"6,1 µm"},{"name":"","range":"500 mm do 600 mm","cmc":"7,5 µm"}],"reference_de":"Internes Verfahren IW/KUM/02/01","regulatory_area_de":"Länge","search_de":"Bügelmessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/02/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Bügelmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"1,1 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"1,3 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"1,7 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"2,0 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"3,1 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,0 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 400 mm","cmc":"4,7 µm"},{"name":"","range":"400 mm do 500 mm","cmc":"6,1 µm"},{"name":"","range":"500 mm do 600 mm","cmc":"7,5 µm"}],"reference_zh":"内部程序 IW/KUM/02/01","regulatory_area_zh":"长度","search_zh":"外径千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/02/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"外径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"0,9 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,1 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,3 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,7 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,0 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,1 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,0 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 400 mm","cmc":"4,7 µm"},{"name":"","range":"400 mm do 500 mm","cmc":"6,1 µm"},{"name":"","range":"500 mm do 600 mm","cmc":"7,5 µm"}],"reference_cs":"Vnitřní postup IW/KUM/02/01","regulatory_area_cs":"Délka","search_cs":"Mikrometry pro vnější měření Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/02/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometry pro vnější měření"},{"_id":"cab43ba89c0d2f251d196307","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Mikrometry zewnętrzne cyfrowe\n– rozdzielczość 0,0001 mm","test_object_en":"Digital external micrometers\n– resolution 0,0001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"0,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"0,6 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 25 mm CMC 0,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/02/01","norm_bases":["IW/KUM/02/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry zewnętrzne cyfrowe\n– rozdzielczość 0,0001 mm Wzorcowanie — Długość\n0 mm do 25 mm CMC 0,6 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/02/01 Mikrometry zewnetrzne cyfrowe\n– rozdzielczosc 0,0001 mm Wzorcowanie — Dlugosc\n0 mm do 25 mm CMC 0,6 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/02/01","search_en":"Digital external micrometers – resolution 0,0001 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/02/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":43,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/02/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"0,6 µm"}],"reference_de":"Internes Verfahren IW/KUM/02/01","regulatory_area_de":"Länge","search_de":"Digitale Bügelmessschrauben – Auflösung 0,0001 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/02/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Digitale Bügelmessschrauben\n– Auflösung 0,0001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"0,6 µm"}],"reference_zh":"内部程序 IW/KUM/02/01","regulatory_area_zh":"长度","search_zh":"数显外径千分尺 – 分辨力 0,0001 mm 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/02/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"数显外径千分尺\n– 分辨力 0,0001 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"0,6 µm"}],"reference_cs":"Vnitřní postup IW/KUM/02/01","regulatory_area_cs":"Délka","search_cs":"Digitální mikrometry pro vnější měření – rozlišení 0,0001 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/02/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální mikrometry pro vnější měření\n– rozlišení 0,0001 mm"},{"_id":"62eacd11ebc766b5ac60548e","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Pierścienie wzorcowe:","test_object_en":"Setting rings:","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– za pomocą głowicy","range":"3 mm do 50 mm","cmc":"0,7 µm"},{"name":"– za pomocą głowicy","range":"50 mm do 90 mm","cmc":"0,8 µm"},{"name":"– za pomocą kabłąków","range":"12 mm do 50 mm","cmc":"0,6 µm"},{"name":"– za pomocą kabłąków","range":"50 mm do 100 mm","cmc":"0,7 µm"},{"name":"– za pomocą kabłąków","range":"100 mm do 150 mm","cmc":"1,0 µm"},{"name":"– za pomocą kabłąków","range":"150 mm do 200 mm","cmc":"1,4 µm"},{"name":"– za pomocą kabłąków","range":"200 mm do 250 mm","cmc":"1,8 µm"},{"name":"– za pomocą kabłąków","range":"250 mm do 300 mm","cmc":"2,3 µm"}],"parameters_en":[{"name":"– with the head","range":"3 mm to 50 mm","cmc":"0,7 µm"},{"name":"– with the head","range":"50 mm to 90 mm","cmc":"0,8 µm"},{"name":"– with the bows","range":"12 mm to 50 mm","cmc":"0,6 µm"},{"name":"– with the bows","range":"50 mm to 100 mm","cmc":"0,7 µm"},{"name":"– with the bows","range":"100 mm to 150 mm","cmc":"1,0 µm"},{"name":"– with the bows","range":"150 mm to 200 mm","cmc":"1,4 µm"},{"name":"– with the bows","range":"200 mm to 250 mm","cmc":"1,8 µm"},{"name":"– with the bows","range":"250 mm to 300 mm","cmc":"2,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza MAHR ULM 520 S-E; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a MAHR ULM 520 S-E length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza MAHR ULM 520 S-E","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a MAHR ULM 520 S-E length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– za pomocą głowicy 3 mm do 50 mm CMC 0,7 µm\n– za pomocą głowicy 50 mm do 90 mm CMC 0,8 µm\n– za pomocą kabłąków 12 mm do 50 mm CMC 0,6 µm\n– za pomocą kabłąków 50 mm do 100 mm CMC 0,7 µm\n– za pomocą kabłąków 100 mm do 150 mm CMC 1,0 µm\n– za pomocą kabłąków 150 mm do 200 mm CMC 1,4 µm\n– za pomocą kabłąków 200 mm do 250 mm CMC 1,8 µm\n– za pomocą kabłąków 250 mm do 300 mm CMC 2,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza MAHR ULM 520 S-E; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/22/01","norm_bases":["IW/KUM/22/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pierścienie wzorcowe: Wzorcowanie — Długość\nZakres:\n– za pomocą głowicy 3 mm do 50 mm CMC 0,7 µm\n– za pomocą głowicy 50 mm do 90 mm CMC 0,8 µm\n– za pomocą kabłąków 12 mm do 50 mm CMC 0,6 µm\n– za pomocą kabłąków 50 mm do 100 mm CMC 0,7 µm\n– za pomocą kabłąków 100 mm do 150 mm CMC 1,0 µm\n– za pomocą kabłąków 150 mm do 200 mm CMC 1,4 µm\n– za pomocą kabłąków 200 mm do 250 mm CMC 1,8 µm\n– za pomocą kabłąków 250 mm do 300 mm CMC 2,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza MAHR ULM 520 S-E; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/22/01 Pierscienie wzorcowe: Wzorcowanie — Dlugosc\nZakres:\n– za pomoca glowicy 3 mm do 50 mm CMC 0,7 µm\n– za pomoca glowicy 50 mm do 90 mm CMC 0,8 µm\n– za pomoca kablakow 12 mm do 50 mm CMC 0,6 µm\n– za pomoca kablakow 50 mm do 100 mm CMC 0,7 µm\n– za pomoca kablakow 100 mm do 150 mm CMC 1,0 µm\n– za pomoca kablakow 150 mm do 200 mm CMC 1,4 µm\n– za pomoca kablakow 200 mm do 250 mm CMC 1,8 µm\n– za pomoca kablakow 250 mm do 300 mm CMC 2,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza MAHR ULM 520 S-E; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/22/01","search_en":"Setting rings: Calibration — Length Internal procedure; Direct method using a MAHR ULM 520 S-E length measuring machine; At permanent location (S) Length Internal procedure Direct method using a MAHR ULM 520 S-E length measuring machine At permanent location (S) – with the head – with the head – with the bows – with the bows – with the bows – with the bows – with the bows – with the bows Internal procedure IW/KUM/22/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":44,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/22/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– mit dem Messkopf","range":"3 mm to 50 mm","cmc":"0,7 µm"},{"name":"– mit dem Messkopf","range":"50 mm to 90 mm","cmc":"0,8 µm"},{"name":"– mit Messbügeln","range":"12 mm to 50 mm","cmc":"0,6 µm"},{"name":"– mit Messbügeln","range":"50 mm to 100 mm","cmc":"0,7 µm"},{"name":"– mit Messbügeln","range":"100 mm to 150 mm","cmc":"1,0 µm"},{"name":"– mit Messbügeln","range":"150 mm to 200 mm","cmc":"1,4 µm"},{"name":"– mit Messbügeln","range":"200 mm to 250 mm","cmc":"1,8 µm"},{"name":"– mit Messbügeln","range":"250 mm to 300 mm","cmc":"2,3 µm"}],"reference_de":"Internes Verfahren IW/KUM/22/01","regulatory_area_de":"Länge","search_de":"Einstellringe: Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät MAHR ULM 520 S-E; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Längenmessgerät MAHR ULM 520 S-E Am festen Standort (S) – mit dem Messkopf – mit dem Messkopf – mit Messbügeln – mit Messbügeln – mit Messbügeln – mit Messbügeln – mit Messbügeln – mit Messbügeln Internes Verfahren IW/KUM/22/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät MAHR ULM 520 S-E; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Längenmessgerät MAHR ULM 520 S-E","Am festen Standort (S)"],"test_object_de":"Einstellringe:","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 用测头","range":"3 mm to 50 mm","cmc":"0,7 µm"},{"name":"– 用测头","range":"50 mm to 90 mm","cmc":"0,8 µm"},{"name":"– 用测量臂","range":"12 mm to 50 mm","cmc":"0,6 µm"},{"name":"– 用测量臂","range":"50 mm to 100 mm","cmc":"0,7 µm"},{"name":"– 用测量臂","range":"100 mm to 150 mm","cmc":"1,0 µm"},{"name":"– 用测量臂","range":"150 mm to 200 mm","cmc":"1,4 µm"},{"name":"– 用测量臂","range":"200 mm to 250 mm","cmc":"1,8 µm"},{"name":"– 用测量臂","range":"250 mm to 300 mm","cmc":"2,3 µm"}],"reference_zh":"内部程序 IW/KUM/22/01","regulatory_area_zh":"长度","search_zh":"校对环规： 校准 — 长度 内部程序；使用MAHR ULM 520 S-E测长仪的直接法；在固定地点 (S) 长度 内部程序 使用MAHR ULM 520 S-E测长仪的直接法 在固定地点 (S) – 用测头 – 用测头 – 用测量臂 – 用测量臂 – 用测量臂 – 用测量臂 – 用测量臂 – 用测量臂 内部程序 IW/KUM/22/01","technique_zh":"内部程序；使用MAHR ULM 520 S-E测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR ULM 520 S-E测长仪的直接法","在固定地点 (S)"],"test_object_zh":"校对环规：","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– pomocí hlavice","range":"3 mm to 50 mm","cmc":"0,7 µm"},{"name":"– pomocí hlavice","range":"50 mm to 90 mm","cmc":"0,8 µm"},{"name":"– pomocí třmenů","range":"12 mm to 50 mm","cmc":"0,6 µm"},{"name":"– pomocí třmenů","range":"50 mm to 100 mm","cmc":"0,7 µm"},{"name":"– pomocí třmenů","range":"100 mm to 150 mm","cmc":"1,0 µm"},{"name":"– pomocí třmenů","range":"150 mm to 200 mm","cmc":"1,4 µm"},{"name":"– pomocí třmenů","range":"200 mm to 250 mm","cmc":"1,8 µm"},{"name":"– pomocí třmenů","range":"250 mm to 300 mm","cmc":"2,3 µm"}],"reference_cs":"Vnitřní postup IW/KUM/22/01","regulatory_area_cs":"Délka","search_cs":"Nastavovací kroužky: Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru MAHR ULM 520 S-E; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru MAHR ULM 520 S-E Ve stálé lokalitě (S) – pomocí hlavice – pomocí hlavice – pomocí třmenů – pomocí třmenů – pomocí třmenů – pomocí třmenů – pomocí třmenů – pomocí třmenů Vnitřní postup IW/KUM/22/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru MAHR ULM 520 S-E; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru MAHR ULM 520 S-E","Ve stálé lokalitě (S)"],"test_object_cs":"Nastavovací kroužky:"},{"_id":"7f1232a226d8c67cf9b516b3","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Płaskorównoległe płytki interferencyjne","test_object_en":"Plane-parallel optical flats","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– odchyłka długości","range":"12 mm","cmc":"0,5 µm"},{"name":"– odchyłka długości","range":"15 mm","cmc":"0,5 µm"},{"name":"– odchyłka długości","range":"27 mm","cmc":"0,7 µm"},{"name":"– odchyłka długości","range":"40 mm","cmc":"0,9 µm"},{"name":"– odchyłka długości","range":"52 mm","cmc":"1,1 µm"},{"name":"– odchyłka długości","range":"65 mm","cmc":"1,3 µm"},{"name":"– odchyłka długości","range":"77 mm","cmc":"1,5 µm"}],"parameters_en":[{"name":"– length deviation","range":"12 mm","cmc":"0,5 µm"},{"name":"– length deviation","range":"15 mm","cmc":"0,5 µm"},{"name":"– length deviation","range":"27 mm","cmc":"0,7 µm"},{"name":"– length deviation","range":"40 mm","cmc":"0,9 µm"},{"name":"– length deviation","range":"52 mm","cmc":"1,1 µm"},{"name":"– length deviation","range":"65 mm","cmc":"1,3 µm"},{"name":"– length deviation","range":"77 mm","cmc":"1,5 µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika optycznego MOP 02/20; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparative method using gauge blocks and a MOP 02/20 optical probe; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika optycznego MOP 02/20","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparative method using gauge blocks and a MOP 02/20 optical probe","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– odchyłka długości 12 mm CMC 0,5 µm\n– odchyłka długości 15 mm CMC 0,5 µm\n– odchyłka długości 27 mm CMC 0,7 µm\n– odchyłka długości 40 mm CMC 0,9 µm\n– odchyłka długości 52 mm CMC 1,1 µm\n– odchyłka długości 65 mm CMC 1,3 µm\n– odchyłka długości 77 mm CMC 1,5 µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika optycznego MOP 02/20; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/08/01","norm_bases":["IW/KUM/08/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Płaskorównoległe płytki interferencyjne Wzorcowanie — Długość\nZakres:\n– odchyłka długości 12 mm CMC 0,5 µm\n– odchyłka długości 15 mm CMC 0,5 µm\n– odchyłka długości 27 mm CMC 0,7 µm\n– odchyłka długości 40 mm CMC 0,9 µm\n– odchyłka długości 52 mm CMC 1,1 µm\n– odchyłka długości 65 mm CMC 1,3 µm\n– odchyłka długości 77 mm CMC 1,5 µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika optycznego MOP 02/20; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/08/01 Plaskorownolegle plytki interferencyjne Wzorcowanie — Dlugosc\nZakres:\n– odchylka dlugosci 12 mm CMC 0,5 µm\n– odchylka dlugosci 15 mm CMC 0,5 µm\n– odchylka dlugosci 27 mm CMC 0,7 µm\n– odchylka dlugosci 40 mm CMC 0,9 µm\n– odchylka dlugosci 52 mm CMC 1,1 µm\n– odchylka dlugosci 65 mm CMC 1,3 µm\n– odchylka dlugosci 77 mm CMC 1,5 µm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem plytek wzorcowych oraz czujnika optycznego MOP 02/20; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/08/01","search_en":"Plane-parallel optical flats Calibration — Length Internal procedure; Comparative method using gauge blocks and a MOP 02/20 optical probe; At permanent location (S) Length Internal procedure Comparative method using gauge blocks and a MOP 02/20 optical probe At permanent location (S) – length deviation – length deviation – length deviation – length deviation – length deviation – length deviation – length deviation Internal procedure IW/KUM/08/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":45,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/08/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Längenabweichung","range":"12 mm","cmc":"0,5 µm"},{"name":"– Längenabweichung","range":"15 mm","cmc":"0,5 µm"},{"name":"– Längenabweichung","range":"27 mm","cmc":"0,7 µm"},{"name":"– Längenabweichung","range":"40 mm","cmc":"0,9 µm"},{"name":"– Längenabweichung","range":"52 mm","cmc":"1,1 µm"},{"name":"– Längenabweichung","range":"65 mm","cmc":"1,3 µm"},{"name":"– Längenabweichung","range":"77 mm","cmc":"1,5 µm"}],"reference_de":"Internes Verfahren IW/KUM/08/01","regulatory_area_de":"Länge","search_de":"Planparallele Interferenzplatten Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit Parallelendmaßen und einem optischen Messtaster MOP 02/20; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit Parallelendmaßen und einem optischen Messtaster MOP 02/20 Am festen Standort (S) – Längenabweichung – Längenabweichung – Längenabweichung – Längenabweichung – Längenabweichung – Längenabweichung – Längenabweichung Internes Verfahren IW/KUM/08/01","technique_de":"Internes Verfahren; Vergleichsverfahren mit Parallelendmaßen und einem optischen Messtaster MOP 02/20; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit Parallelendmaßen und einem optischen Messtaster MOP 02/20","Am festen Standort (S)"],"test_object_de":"Planparallele Interferenzplatten","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 长度偏差","range":"12 mm","cmc":"0,5 µm"},{"name":"– 长度偏差","range":"15 mm","cmc":"0,5 µm"},{"name":"– 长度偏差","range":"27 mm","cmc":"0,7 µm"},{"name":"– 长度偏差","range":"40 mm","cmc":"0,9 µm"},{"name":"– 长度偏差","range":"52 mm","cmc":"1,1 µm"},{"name":"– 长度偏差","range":"65 mm","cmc":"1,3 µm"},{"name":"– 长度偏差","range":"77 mm","cmc":"1,5 µm"}],"reference_zh":"内部程序 IW/KUM/08/01","regulatory_area_zh":"长度","search_zh":"平行平晶干涉板 校准 — 长度 内部程序；使用量块和MOP 02/20光学测头的比较法；在固定地点 (S) 长度 内部程序 使用量块和MOP 02/20光学测头的比较法 在固定地点 (S) – 长度偏差 – 长度偏差 – 长度偏差 – 长度偏差 – 长度偏差 – 长度偏差 – 长度偏差 内部程序 IW/KUM/08/01","technique_zh":"内部程序；使用量块和MOP 02/20光学测头的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用量块和MOP 02/20光学测头的比较法","在固定地点 (S)"],"test_object_zh":"平行平晶干涉板","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– odchylka délky","range":"12 mm","cmc":"0,5 µm"},{"name":"– odchylka délky","range":"15 mm","cmc":"0,5 µm"},{"name":"– odchylka délky","range":"27 mm","cmc":"0,7 µm"},{"name":"– odchylka délky","range":"40 mm","cmc":"0,9 µm"},{"name":"– odchylka délky","range":"52 mm","cmc":"1,1 µm"},{"name":"– odchylka délky","range":"65 mm","cmc":"1,3 µm"},{"name":"– odchylka délky","range":"77 mm","cmc":"1,5 µm"}],"reference_cs":"Vnitřní postup IW/KUM/08/01","regulatory_area_cs":"Délka","search_cs":"Planparalelní interferenční destičky Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím koncových měrek a optického snímače MOP 02/20; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím koncových měrek a optického snímače MOP 02/20 Ve stálé lokalitě (S) – odchylka délky – odchylka délky – odchylka délky – odchylka délky – odchylka délky – odchylka délky – odchylka délky Vnitřní postup IW/KUM/08/01","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím koncových měrek a optického snímače MOP 02/20; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím koncových měrek a optického snímače MOP 02/20","Ve stálé lokalitě (S)"],"test_object_cs":"Planparalelní interferenční destičky"},{"_id":"fbd94924a847bdad97942b67","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Płytki wzorcowe (klasy 0, 1, 2)","test_object_en":"Gauge blocks (classes 0, 1, 2)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,5 mm do 100 mm","cmc":"Q[0,06; 1,05∙L] µm"}],"parameters_en":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,06; 1,05∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego TESA; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparative method using a TESA two-probe comparator; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego TESA","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparative method using a TESA two-probe comparator","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[0,06; 1,05∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego TESA; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/16/01 oparta na PN-EN ISO 3650:2000","norm_bases":["IW/KUM/16/01","PN-EN ISO 3650:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Płytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[0,06; 1,05∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego TESA; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/16/01 oparta na PN-EN ISO 3650:2000 Plytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Dlugosc\n0,5 mm do 100 mm CMC Q[0,06; 1,05∙L] µm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem komparatora dwuczujnikowego TESA; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/16/01 oparta na PN-EN ISO 3650:2000","search_en":"Gauge blocks (classes 0, 1, 2) Calibration — Length Internal procedure; Comparative method using a TESA two-probe comparator; At permanent location (S) Length Internal procedure Comparative method using a TESA two-probe comparator At permanent location (S) Internal procedure IW/KUM/16/01 based on PN-EN ISO 3650:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":46,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/16/01 based on PN-EN ISO 3650:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,06; 1,05∙L] µm"}],"reference_de":"Internes Verfahren IW/KUM/16/01 auf Grundlage von PN-EN ISO 3650:2000","regulatory_area_de":"Länge","search_de":"Parallelendmaße (Klassen 0, 1, 2) Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit einem Zweitaster-Komparator TESA; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit einem Zweitaster-Komparator TESA Am festen Standort (S) Internes Verfahren IW/KUM/16/01 auf Grundlage von PN-EN ISO 3650:2000","technique_de":"Internes Verfahren; Vergleichsverfahren mit einem Zweitaster-Komparator TESA; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit einem Zweitaster-Komparator TESA","Am festen Standort (S)"],"test_object_de":"Parallelendmaße (Klassen 0, 1, 2)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,06; 1,05∙L] µm"}],"reference_zh":"内部程序 IW/KUM/16/01 依据PN-EN ISO 3650:2000","regulatory_area_zh":"长度","search_zh":"量块（0、1、2 级） 校准 — 长度 内部程序；使用TESA双测头比较仪的比较法；在固定地点 (S) 长度 内部程序 使用TESA双测头比较仪的比较法 在固定地点 (S) 内部程序 IW/KUM/16/01 依据PN-EN ISO 3650:2000","technique_zh":"内部程序；使用TESA双测头比较仪的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用TESA双测头比较仪的比较法","在固定地点 (S)"],"test_object_zh":"量块（0、1、2 级）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,06; 1,05∙L] µm"}],"reference_cs":"Vnitřní postup IW/KUM/16/01 na základě PN-EN ISO 3650:2000","regulatory_area_cs":"Délka","search_cs":"Koncové měrky (třídy 0, 1, 2) Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím dvousnímačového komparátoru TESA; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím dvousnímačového komparátoru TESA Ve stálé lokalitě (S) Vnitřní postup IW/KUM/16/01 na základě PN-EN ISO 3650:2000","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím dvousnímačového komparátoru TESA; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím dvousnímačového komparátoru TESA","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky (třídy 0, 1, 2)"},{"_id":"02063e00b7c53e42cc7dcbf2","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Płytki wzorcowe (klasy 0, 1, 2)","test_object_en":"Gauge blocks (classes 0, 1, 2)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,5 mm do 100 mm","cmc":"Q[0,06; 1,05∙L] µm"}],"parameters_en":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,06; 1,05∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego MAHR; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparative method using a MAHR two-probe comparator; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego MAHR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparative method using a MAHR two-probe comparator","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[0,06; 1,05∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego MAHR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/16/02 oparta na PN-EN ISO 3650:2000","norm_bases":["IW/KUM/16/02","PN-EN ISO 3650:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Płytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Długość\n0,5 mm do 100 mm CMC Q[0,06; 1,05∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego MAHR; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/16/02 oparta na PN-EN ISO 3650:2000 Plytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Dlugosc\n0,5 mm do 100 mm CMC Q[0,06; 1,05∙L] µm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem komparatora dwuczujnikowego MAHR; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/16/02 oparta na PN-EN ISO 3650:2000","search_en":"Gauge blocks (classes 0, 1, 2) Calibration — Length Internal procedure; Comparative method using a MAHR two-probe comparator; At permanent location (S) Length Internal procedure Comparative method using a MAHR two-probe comparator At permanent location (S) Internal procedure IW/KUM/16/02 based on PN-EN ISO 3650:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":47,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/16/02 based on PN-EN ISO 3650:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,06; 1,05∙L] µm"}],"reference_de":"Internes Verfahren IW/KUM/16/02 auf Grundlage von PN-EN ISO 3650:2000","regulatory_area_de":"Länge","search_de":"Parallelendmaße (Klassen 0, 1, 2) Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit einem Zweitaster-Komparator MAHR; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit einem Zweitaster-Komparator MAHR Am festen Standort (S) Internes Verfahren IW/KUM/16/02 auf Grundlage von PN-EN ISO 3650:2000","technique_de":"Internes Verfahren; Vergleichsverfahren mit einem Zweitaster-Komparator MAHR; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit einem Zweitaster-Komparator MAHR","Am festen Standort (S)"],"test_object_de":"Parallelendmaße (Klassen 0, 1, 2)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,06; 1,05∙L] µm"}],"reference_zh":"内部程序 IW/KUM/16/02 依据PN-EN ISO 3650:2000","regulatory_area_zh":"长度","search_zh":"量块（0、1、2 级） 校准 — 长度 内部程序；使用MAHR双测头比较仪的比较法；在固定地点 (S) 长度 内部程序 使用MAHR双测头比较仪的比较法 在固定地点 (S) 内部程序 IW/KUM/16/02 依据PN-EN ISO 3650:2000","technique_zh":"内部程序；使用MAHR双测头比较仪的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR双测头比较仪的比较法","在固定地点 (S)"],"test_object_zh":"量块（0、1、2 级）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,5 mm to 100 mm","cmc":"Q[0,06; 1,05∙L] µm"}],"reference_cs":"Vnitřní postup IW/KUM/16/02 na základě PN-EN ISO 3650:2000","regulatory_area_cs":"Délka","search_cs":"Koncové měrky (třídy 0, 1, 2) Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím dvousnímačového komparátoru MAHR; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím dvousnímačového komparátoru MAHR Ve stálé lokalitě (S) Vnitřní postup IW/KUM/16/02 na základě PN-EN ISO 3650:2000","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím dvousnímačového komparátoru MAHR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím dvousnímačového komparátoru MAHR","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky (třídy 0, 1, 2)"},{"_id":"99cdc364fbc1d0ae141cd31d","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Płytki wzorcowe (klasy 0, 1, 2)","test_object_en":"Gauge blocks (classes 0, 1, 2)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"125 mm do 175 mm","cmc":"Q[0,07; 1,00∙L] µm"}],"parameters_en":[{"name":"","range":"125 mm to 175 mm","cmc":"Q[0,07; 1,00∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego MAHR; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparative method using a MAHR two-probe comparator; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego MAHR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparative method using a MAHR two-probe comparator","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n125 mm do 175 mm CMC Q[0,07; 1,00∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego MAHR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/16/02 oparta na PN-EN ISO 3650:2000","norm_bases":["IW/KUM/16/02","PN-EN ISO 3650:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Płytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Długość\n125 mm do 175 mm CMC Q[0,07; 1,00∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem komparatora dwuczujnikowego MAHR; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/16/02 oparta na PN-EN ISO 3650:2000 Plytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Dlugosc\n125 mm do 175 mm CMC Q[0,07; 1,00∙L] µm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem komparatora dwuczujnikowego MAHR; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/16/02 oparta na PN-EN ISO 3650:2000","search_en":"Gauge blocks (classes 0, 1, 2) Calibration — Length Internal procedure; Comparative method using a MAHR two-probe comparator; At permanent location (S) Length Internal procedure Comparative method using a MAHR two-probe comparator At permanent location (S) Internal procedure IW/KUM/16/02 based on PN-EN ISO 3650:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":48,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/16/02 based on PN-EN ISO 3650:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"125 mm to 175 mm","cmc":"Q[0,07; 1,00∙L] µm"}],"reference_de":"Internes Verfahren IW/KUM/16/02 auf Grundlage von PN-EN ISO 3650:2000","regulatory_area_de":"Länge","search_de":"Parallelendmaße (Klassen 0, 1, 2) Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit einem Zweitaster-Komparator MAHR; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit einem Zweitaster-Komparator MAHR Am festen Standort (S) Internes Verfahren IW/KUM/16/02 auf Grundlage von PN-EN ISO 3650:2000","technique_de":"Internes Verfahren; Vergleichsverfahren mit einem Zweitaster-Komparator MAHR; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit einem Zweitaster-Komparator MAHR","Am festen Standort (S)"],"test_object_de":"Parallelendmaße (Klassen 0, 1, 2)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"125 mm to 175 mm","cmc":"Q[0,07; 1,00∙L] µm"}],"reference_zh":"内部程序 IW/KUM/16/02 依据PN-EN ISO 3650:2000","regulatory_area_zh":"长度","search_zh":"量块（0、1、2 级） 校准 — 长度 内部程序；使用MAHR双测头比较仪的比较法；在固定地点 (S) 长度 内部程序 使用MAHR双测头比较仪的比较法 在固定地点 (S) 内部程序 IW/KUM/16/02 依据PN-EN ISO 3650:2000","technique_zh":"内部程序；使用MAHR双测头比较仪的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR双测头比较仪的比较法","在固定地点 (S)"],"test_object_zh":"量块（0、1、2 级）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"125 mm to 175 mm","cmc":"Q[0,07; 1,00∙L] µm"}],"reference_cs":"Vnitřní postup IW/KUM/16/02 na základě PN-EN ISO 3650:2000","regulatory_area_cs":"Délka","search_cs":"Koncové měrky (třídy 0, 1, 2) Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím dvousnímačového komparátoru MAHR; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím dvousnímačového komparátoru MAHR Ve stálé lokalitě (S) Vnitřní postup IW/KUM/16/02 na základě PN-EN ISO 3650:2000","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím dvousnímačového komparátoru MAHR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím dvousnímačového komparátoru MAHR","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky (třídy 0, 1, 2)"},{"_id":"8068f8c8ae24ee443c371b44","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Płytki wzorcowe (klasy 0, 1, 2)","test_object_en":"Gauge blocks (classes 0, 1, 2)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"150 mm do 500 mm","cmc":"Q[0,14; 1,03∙L] µm"}],"parameters_en":[{"name":"","range":"150 mm to 500 mm","cmc":"Q[0,14; 1,03∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem długościomierza poziomego MAHR ULM 520 S-E; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparative method using a MAHR ULM 520 S-E horizontal length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem długościomierza poziomego MAHR ULM 520 S-E","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparative method using a MAHR ULM 520 S-E horizontal length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n150 mm do 500 mm CMC Q[0,14; 1,03∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem długościomierza poziomego MAHR ULM 520 S-E; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/22/07","norm_bases":["IW/KUM/22/07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Płytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Długość\n150 mm do 500 mm CMC Q[0,14; 1,03∙L] µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem długościomierza poziomego MAHR ULM 520 S-E; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/22/07 Plytki wzorcowe (klasy 0, 1, 2) Wzorcowanie — Dlugosc\n150 mm do 500 mm CMC Q[0,14; 1,03∙L] µm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem dlugosciomierza poziomego MAHR ULM 520 S-E; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/22/07","search_en":"Gauge blocks (classes 0, 1, 2) Calibration — Length Internal procedure; Comparative method using a MAHR ULM 520 S-E horizontal length measuring machine; At permanent location (S) Length Internal procedure Comparative method using a MAHR ULM 520 S-E horizontal length measuring machine At permanent location (S) Internal procedure IW/KUM/22/07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":49,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/22/07","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"150 mm to 500 mm","cmc":"Q[0,14; 1,03∙L] µm"}],"reference_de":"Internes Verfahren IW/KUM/22/07","regulatory_area_de":"Länge","search_de":"Parallelendmaße (Klassen 0, 1, 2) Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit einem Horizontal-Längenmessgerät MAHR ULM 520 S-E; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit einem Horizontal-Längenmessgerät MAHR ULM 520 S-E Am festen Standort (S) Internes Verfahren IW/KUM/22/07","technique_de":"Internes Verfahren; Vergleichsverfahren mit einem Horizontal-Längenmessgerät MAHR ULM 520 S-E; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit einem Horizontal-Längenmessgerät MAHR ULM 520 S-E","Am festen Standort (S)"],"test_object_de":"Parallelendmaße (Klassen 0, 1, 2)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"150 mm to 500 mm","cmc":"Q[0,14; 1,03∙L] µm"}],"reference_zh":"内部程序 IW/KUM/22/07","regulatory_area_zh":"长度","search_zh":"量块（0、1、2 级） 校准 — 长度 内部程序；使用MAHR ULM 520 S-E卧式测长仪的比较法；在固定地点 (S) 长度 内部程序 使用MAHR ULM 520 S-E卧式测长仪的比较法 在固定地点 (S) 内部程序 IW/KUM/22/07","technique_zh":"内部程序；使用MAHR ULM 520 S-E卧式测长仪的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR ULM 520 S-E卧式测长仪的比较法","在固定地点 (S)"],"test_object_zh":"量块（0、1、2 级）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"150 mm to 500 mm","cmc":"Q[0,14; 1,03∙L] µm"}],"reference_cs":"Vnitřní postup IW/KUM/22/07","regulatory_area_cs":"Délka","search_cs":"Koncové měrky (třídy 0, 1, 2) Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím vodorovného délkoměru MAHR ULM 520 S-E; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím vodorovného délkoměru MAHR ULM 520 S-E Ve stálé lokalitě (S) Vnitřní postup IW/KUM/22/07","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím vodorovného délkoměru MAHR ULM 520 S-E; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím vodorovného délkoměru MAHR ULM 520 S-E","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky (třídy 0, 1, 2)"},{"_id":"31113cdef54c426ad4398961","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Przymiary wstęgowe","test_object_en":"Measuring tapes","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 m do 5 m","cmc":"Q[0,11; 0,028∙L] mm"},{"name":"","range":"5 m do 10 m","cmc":"Q[0,16; 0,028∙(L-5)] mm"},{"name":"","range":"10 m do 15 m","cmc":"Q[0,20; 0,028∙(L-10)] mm"},{"name":"","range":"15 m do 20 m","cmc":"Q[0,23; 0,028∙(L-15)] mm"},{"name":"","range":"20 m do 25 m","cmc":"Q[0,26; 0,028∙(L-20)] mm"}],"parameters_en":[{"name":"","range":"0 m to 5 m","cmc":"Q[0,11; 0,028∙L] mm"},{"name":"","range":"5 m do 10 m","cmc":"Q[0,16; 0,028∙(L-5)] mm"},{"name":"","range":"10 m do 15 m","cmc":"Q[0,20; 0,028∙(L-10)] mm"},{"name":"","range":"15 m do 20 m","cmc":"Q[0,23; 0,028∙(L-15)] mm"},{"name":"","range":"20 m do 25 m","cmc":"Q[0,26; 0,028∙(L-20)] mm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego POLMIAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparative method using a POLMIAR rigid rule; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem przymiaru sztywnego POLMIAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparative method using a POLMIAR rigid rule","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 m do 5 m CMC Q[0,11; 0,028∙L] mm\n5 m do 10 m CMC Q[0,16; 0,028∙(L-5)] mm\n10 m do 15 m CMC Q[0,20; 0,028∙(L-10)] mm\n15 m do 20 m CMC Q[0,23; 0,028∙(L-15)] mm\n20 m do 25 m CMC Q[0,26; 0,028∙(L-20)] mm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego POLMIAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/13/01","norm_bases":["IW/KUM/13/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Przymiary wstęgowe Wzorcowanie — Długość\nZakres:\n0 m do 5 m CMC Q[0,11; 0,028∙L] mm\n5 m do 10 m CMC Q[0,16; 0,028∙(L-5)] mm\n10 m do 15 m CMC Q[0,20; 0,028∙(L-10)] mm\n15 m do 20 m CMC Q[0,23; 0,028∙(L-15)] mm\n20 m do 25 m CMC Q[0,26; 0,028∙(L-20)] mm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego POLMIAR; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/13/01 Przymiary wstegowe Wzorcowanie — Dlugosc\nZakres:\n0 m do 5 m CMC Q[0,11; 0,028∙L] mm\n5 m do 10 m CMC Q[0,16; 0,028∙(L-5)] mm\n10 m do 15 m CMC Q[0,20; 0,028∙(L-10)] mm\n15 m do 20 m CMC Q[0,23; 0,028∙(L-15)] mm\n20 m do 25 m CMC Q[0,26; 0,028∙(L-20)] mm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem przymiaru sztywnego POLMIAR; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/13/01","search_en":"Measuring tapes Calibration — Length Internal procedure; Comparative method using a POLMIAR rigid rule; At permanent location (S) Length Internal procedure Comparative method using a POLMIAR rigid rule At permanent location (S) Internal procedure IW/KUM/13/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":50,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/13/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 m bis 5 m","cmc":"Q[0,11; 0,028∙L] mm"},{"name":"","range":"5 m do 10 m","cmc":"Q[0,16; 0,028∙(L-5)] mm"},{"name":"","range":"10 m do 15 m","cmc":"Q[0,20; 0,028∙(L-10)] mm"},{"name":"","range":"15 m do 20 m","cmc":"Q[0,23; 0,028∙(L-15)] mm"},{"name":"","range":"20 m do 25 m","cmc":"Q[0,26; 0,028∙(L-20)] mm"}],"reference_de":"Internes Verfahren IW/KUM/13/01","regulatory_area_de":"Länge","search_de":"Bandmaße Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit einem starren Maßstab POLMIAR; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit einem starren Maßstab POLMIAR Am festen Standort (S) Internes Verfahren IW/KUM/13/01","technique_de":"Internes Verfahren; Vergleichsverfahren mit einem starren Maßstab POLMIAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit einem starren Maßstab POLMIAR","Am festen Standort (S)"],"test_object_de":"Bandmaße","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 m 至 5 m","cmc":"Q[0,11; 0,028∙L] mm"},{"name":"","range":"5 m do 10 m","cmc":"Q[0,16; 0,028∙(L-5)] mm"},{"name":"","range":"10 m do 15 m","cmc":"Q[0,20; 0,028∙(L-10)] mm"},{"name":"","range":"15 m do 20 m","cmc":"Q[0,23; 0,028∙(L-15)] mm"},{"name":"","range":"20 m do 25 m","cmc":"Q[0,26; 0,028∙(L-20)] mm"}],"reference_zh":"内部程序 IW/KUM/13/01","regulatory_area_zh":"长度","search_zh":"卷尺 校准 — 长度 内部程序；使用POLMIAR刚性量尺的比较法；在固定地点 (S) 长度 内部程序 使用POLMIAR刚性量尺的比较法 在固定地点 (S) 内部程序 IW/KUM/13/01","technique_zh":"内部程序；使用POLMIAR刚性量尺的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用POLMIAR刚性量尺的比较法","在固定地点 (S)"],"test_object_zh":"卷尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 m do 5 m","cmc":"Q[0,11; 0,028∙L] mm"},{"name":"","range":"5 m do 10 m","cmc":"Q[0,16; 0,028∙(L-5)] mm"},{"name":"","range":"10 m do 15 m","cmc":"Q[0,20; 0,028∙(L-10)] mm"},{"name":"","range":"15 m do 20 m","cmc":"Q[0,23; 0,028∙(L-15)] mm"},{"name":"","range":"20 m do 25 m","cmc":"Q[0,26; 0,028∙(L-20)] mm"}],"reference_cs":"Vnitřní postup IW/KUM/13/01","regulatory_area_cs":"Délka","search_cs":"Měřicí pásma Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím pevného měřítka POLMIAR; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím pevného měřítka POLMIAR Ve stálé lokalitě (S) Vnitřní postup IW/KUM/13/01","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím pevného měřítka POLMIAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím pevného měřítka POLMIAR","Ve stálé lokalitě (S)"],"test_object_cs":"Měřicí pásma"},{"_id":"a4a3a15c3f67296460a23268","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Przymiary sztywne\nPrzymiary półsztywne","test_object_en":"Rigid rules\nSemi-rigid rules","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 m do 3 m","cmc":"Q[0,11; 0,028∙L] mm"},{"name":"","range":"0 m do 5 m","cmc":"Q[0,11; 0,028∙L] mm"}],"parameters_en":[{"name":"","range":"0 m do 3 m","cmc":"Q[0,11; 0,028∙L] mm"},{"name":"","range":"0 m to 5 m","cmc":"Q[0,11; 0,028∙L] mm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego lub półsztywnego POLMIAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparative method using a POLMIAR rigid or semi-rigid rule; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem przymiaru sztywnego lub półsztywnego POLMIAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparative method using a POLMIAR rigid or semi-rigid rule","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 m do 3 m CMC Q[0,11; 0,028∙L] mm\n0 m do 5 m CMC Q[0,11; 0,028∙L] mm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego lub półsztywnego POLMIAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/13/02","norm_bases":["IW/KUM/13/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Przymiary sztywne\nPrzymiary półsztywne Wzorcowanie — Długość\nZakres:\n0 m do 3 m CMC Q[0,11; 0,028∙L] mm\n0 m do 5 m CMC Q[0,11; 0,028∙L] mm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem przymiaru sztywnego lub półsztywnego POLMIAR; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/13/02 Przymiary sztywne\nPrzymiary polsztywne Wzorcowanie — Dlugosc\nZakres:\n0 m do 3 m CMC Q[0,11; 0,028∙L] mm\n0 m do 5 m CMC Q[0,11; 0,028∙L] mm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem przymiaru sztywnego lub polsztywnego POLMIAR; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/13/02","search_en":"Rigid rules Semi-rigid rules Calibration — Length Internal procedure; Comparative method using a POLMIAR rigid or semi-rigid rule; At permanent location (S) Length Internal procedure Comparative method using a POLMIAR rigid or semi-rigid rule At permanent location (S) Internal procedure IW/KUM/13/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":51,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/13/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 m do 3 m","cmc":"Q[0,11; 0,028∙L] mm"},{"name":"","range":"0 m bis 5 m","cmc":"Q[0,11; 0,028∙L] mm"}],"reference_de":"Internes Verfahren IW/KUM/13/02","regulatory_area_de":"Länge","search_de":"Starre Maßstäbe Halbstarre Maßstäbe Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit einem starren oder halbstarren Maßstab POLMIAR; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit einem starren oder halbstarren Maßstab POLMIAR Am festen Standort (S) Internes Verfahren IW/KUM/13/02","technique_de":"Internes Verfahren; Vergleichsverfahren mit einem starren oder halbstarren Maßstab POLMIAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit einem starren oder halbstarren Maßstab POLMIAR","Am festen Standort (S)"],"test_object_de":"Starre Maßstäbe\nHalbstarre Maßstäbe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 m do 3 m","cmc":"Q[0,11; 0,028∙L] mm"},{"name":"","range":"0 m 至 5 m","cmc":"Q[0,11; 0,028∙L] mm"}],"reference_zh":"内部程序 IW/KUM/13/02","regulatory_area_zh":"长度","search_zh":"刚性量尺 半刚性量尺 校准 — 长度 内部程序；使用POLMIAR刚性或半刚性量尺的比较法；在固定地点 (S) 长度 内部程序 使用POLMIAR刚性或半刚性量尺的比较法 在固定地点 (S) 内部程序 IW/KUM/13/02","technique_zh":"内部程序；使用POLMIAR刚性或半刚性量尺的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用POLMIAR刚性或半刚性量尺的比较法","在固定地点 (S)"],"test_object_zh":"刚性量尺\n半刚性量尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 m do 3 m","cmc":"Q[0,11; 0,028∙L] mm"},{"name":"","range":"0 m do 5 m","cmc":"Q[0,11; 0,028∙L] mm"}],"reference_cs":"Vnitřní postup IW/KUM/13/02","regulatory_area_cs":"Délka","search_cs":"Tuhá délková měřidla Polotuhá délková měřidla Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím pevného nebo polotuhého měřítka POLMIAR; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím pevného nebo polotuhého měřítka POLMIAR Ve stálé lokalitě (S) Vnitřní postup IW/KUM/13/02","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím pevného nebo polotuhého měřítka POLMIAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím pevného nebo polotuhého měřítka POLMIAR","Ve stálé lokalitě (S)"],"test_object_cs":"Tuhá délková měřidla\nPolotuhá délková měřidla"},{"_id":"e730b43994caf88395696337","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Przymiary sztywne\nPrzymiary półsztywne","test_object_en":"Rigid rules\nSemi-rigid rules","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 300 mm","cmc":"Q[19; 0,04∙L] µm"}],"parameters_en":[{"name":"","range":"0 mm to 300 mm","cmc":"Q[19; 0,04∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an ISD-V300A microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an ISD-V300A microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 300 mm CMC Q[19; 0,04∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/23/01","norm_bases":["IW/KUM/23/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (mm)","note_en":"L - measured quantity (mm)","search_text":"Przymiary sztywne\nPrzymiary półsztywne Wzorcowanie — Długość\n0 mm do 300 mm CMC Q[19; 0,04∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/23/01 Przymiary sztywne\nPrzymiary polsztywne Wzorcowanie — Dlugosc\n0 mm do 300 mm CMC Q[19; 0,04∙L] µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem mikroskopu ISD-V300A; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/23/01","search_en":"Rigid rules Semi-rigid rules Calibration — Length Internal procedure; Direct method using an ISD-V300A microscope; At permanent location (S) Length Internal procedure Direct method using an ISD-V300A microscope At permanent location (S) Internal procedure IW/KUM/23/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":52,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/23/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 300 mm","cmc":"Q[19; 0,04∙L] µm"}],"reference_de":"Internes Verfahren IW/KUM/23/01","regulatory_area_de":"Länge","search_de":"Starre Maßstäbe Halbstarre Maßstäbe Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Mikroskop ISD-V300A; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Mikroskop ISD-V300A Am festen Standort (S) Internes Verfahren IW/KUM/23/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Mikroskop ISD-V300A; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Mikroskop ISD-V300A","Am festen Standort (S)"],"test_object_de":"Starre Maßstäbe\nHalbstarre Maßstäbe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 300 mm","cmc":"Q[19; 0,04∙L] µm"}],"reference_zh":"内部程序 IW/KUM/23/01","regulatory_area_zh":"长度","search_zh":"刚性量尺 半刚性量尺 校准 — 长度 内部程序；使用ISD-V300A显微镜的直接法；在固定地点 (S) 长度 内部程序 使用ISD-V300A显微镜的直接法 在固定地点 (S) 内部程序 IW/KUM/23/01","technique_zh":"内部程序；使用ISD-V300A显微镜的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ISD-V300A显微镜的直接法","在固定地点 (S)"],"test_object_zh":"刚性量尺\n半刚性量尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 300 mm","cmc":"Q[19; 0,04∙L] µm"}],"reference_cs":"Vnitřní postup IW/KUM/23/01","regulatory_area_cs":"Délka","search_cs":"Tuhá délková měřidla Polotuhá délková měřidla Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím mikroskopu ISD-V300A; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím mikroskopu ISD-V300A Ve stálé lokalitě (S) Vnitřní postup IW/KUM/23/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím mikroskopu ISD-V300A; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím mikroskopu ISD-V300A","Ve stálé lokalitě (S)"],"test_object_cs":"Tuhá délková měřidla\nPolotuhá délková měřidla"},{"_id":"9c0d7450cbacebf52414f91d","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Przyrządy suwmiarkowe specjalne\nSpoinomierze suwmiarkowe cyfrowe","test_object_en":"Special vernier instruments\nDigital vernier weld gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– spoiny na płaszczyźnie","range":"0 mm do 30 mm","cmc":"6 µm"},{"name":"– spoiny w narożach","range":"0 mm do 30 mm","cmc":"10 µm"}],"parameters_en":[{"name":"– welds on a plane","range":"0 mm to 30 mm","cmc":"6 µm"},{"name":"– corner welds","range":"0 mm to 30 mm","cmc":"10 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks and measuring rollers","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– spoiny na płaszczyźnie 0 mm do 30 mm CMC 6 µm\n– spoiny w narożach 0 mm do 30 mm CMC 10 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/01/02","norm_bases":["IW/KUM/01/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przyrządy suwmiarkowe specjalne\nSpoinomierze suwmiarkowe cyfrowe Wzorcowanie — Długość\nZakres:\n– spoiny na płaszczyźnie 0 mm do 30 mm CMC 6 µm\n– spoiny w narożach 0 mm do 30 mm CMC 10 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/01/02 Przyrzady suwmiarkowe specjalne\nSpoinomierze suwmiarkowe cyfrowe Wzorcowanie — Dlugosc\nZakres:\n– spoiny na plaszczyznie 0 mm do 30 mm CMC 6 µm\n– spoiny w narozach 0 mm do 30 mm CMC 10 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych oraz waleczkow pomiarowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/01/02","search_en":"Special vernier instruments Digital vernier weld gauges Calibration — Length Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S) Length Internal procedure Direct method using gauge blocks and measuring rollers At permanent location (S) – welds on a plane – corner welds Internal procedure IW/KUM/01/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":53,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/01/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Nähte auf einer Ebene","range":"0 mm to 30 mm","cmc":"6 µm"},{"name":"– Nähte in Ecken","range":"0 mm to 30 mm","cmc":"10 µm"}],"reference_de":"Internes Verfahren IW/KUM/01/02","regulatory_area_de":"Länge","search_de":"Spezialmessschieber Digitale Schweißnahtmessschieber Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Parallelendmaßen und Messrollen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen und Messrollen Am festen Standort (S) – Nähte auf einer Ebene – Nähte in Ecken Internes Verfahren IW/KUM/01/02","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen und Messrollen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen und Messrollen","Am festen Standort (S)"],"test_object_de":"Spezialmessschieber\nDigitale Schweißnahtmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 平面焊缝","range":"0 mm to 30 mm","cmc":"6 µm"},{"name":"– 角部焊缝","range":"0 mm to 30 mm","cmc":"10 µm"}],"reference_zh":"内部程序 IW/KUM/01/02","regulatory_area_zh":"长度","search_zh":"专用游标量具 数显游标焊缝规 校准 — 长度 内部程序；使用量块和测量棒的直接法；在固定地点 (S) 长度 内部程序 使用量块和测量棒的直接法 在固定地点 (S) – 平面焊缝 – 角部焊缝 内部程序 IW/KUM/01/02","technique_zh":"内部程序；使用量块和测量棒的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块和测量棒的直接法","在固定地点 (S)"],"test_object_zh":"专用游标量具\n数显游标焊缝规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– svary v rovině","range":"0 mm to 30 mm","cmc":"6 µm"},{"name":"– svary v rozích","range":"0 mm to 30 mm","cmc":"10 µm"}],"reference_cs":"Vnitřní postup IW/KUM/01/02","regulatory_area_cs":"Délka","search_cs":"Speciální posuvná měřidla Digitální posuvná měřidla svarů Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek a měřicích válečků; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek a měřicích válečků Ve stálé lokalitě (S) – svary v rovině – svary v rozích Vnitřní postup IW/KUM/01/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek a měřicích válečků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek a měřicích válečků","Ve stálé lokalitě (S)"],"test_object_cs":"Speciální posuvná měřidla\nDigitální posuvná měřidla svarů"},{"_id":"1b688d4c7b5e6314fa6a7363","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Przyrządy suwmiarkowe specjalne\nSpoinomierze suwmiarkowe analogowe","test_object_en":"Special vernier instruments\nAnalogue vernier weld gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– spoiny na płaszczyźnie","range":"0 mm do 30 mm","cmc":"0,06 mm"},{"name":"– spoiny w narożach","range":"0 mm do 30 mm","cmc":"0,06 mm"}],"parameters_en":[{"name":"– welds on a plane","range":"0 mm to 30 mm","cmc":"0,06 mm"},{"name":"– corner welds","range":"0 mm to 30 mm","cmc":"0,06 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks and measuring rollers","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– spoiny na płaszczyźnie 0 mm do 30 mm CMC 0,06 mm\n– spoiny w narożach 0 mm do 30 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/01/02","norm_bases":["IW/KUM/01/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przyrządy suwmiarkowe specjalne\nSpoinomierze suwmiarkowe analogowe Wzorcowanie — Długość\nZakres:\n– spoiny na płaszczyźnie 0 mm do 30 mm CMC 0,06 mm\n– spoiny w narożach 0 mm do 30 mm CMC 0,06 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/01/02 Przyrzady suwmiarkowe specjalne\nSpoinomierze suwmiarkowe analogowe Wzorcowanie — Dlugosc\nZakres:\n– spoiny na plaszczyznie 0 mm do 30 mm CMC 0,06 mm\n– spoiny w narozach 0 mm do 30 mm CMC 0,06 mm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych oraz waleczkow pomiarowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/01/02","search_en":"Special vernier instruments Analogue vernier weld gauges Calibration — Length Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S) Length Internal procedure Direct method using gauge blocks and measuring rollers At permanent location (S) – welds on a plane – corner welds Internal procedure IW/KUM/01/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":54,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/01/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Nähte auf einer Ebene","range":"0 mm to 30 mm","cmc":"0,06 mm"},{"name":"– Nähte in Ecken","range":"0 mm to 30 mm","cmc":"0,06 mm"}],"reference_de":"Internes Verfahren IW/KUM/01/02","regulatory_area_de":"Länge","search_de":"Spezialmessschieber Analoge Schweißnahtmessschieber Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Parallelendmaßen und Messrollen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen und Messrollen Am festen Standort (S) – Nähte auf einer Ebene – Nähte in Ecken Internes Verfahren IW/KUM/01/02","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen und Messrollen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen und Messrollen","Am festen Standort (S)"],"test_object_de":"Spezialmessschieber\nAnaloge Schweißnahtmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 平面焊缝","range":"0 mm to 30 mm","cmc":"0,06 mm"},{"name":"– 角部焊缝","range":"0 mm to 30 mm","cmc":"0,06 mm"}],"reference_zh":"内部程序 IW/KUM/01/02","regulatory_area_zh":"长度","search_zh":"专用游标量具 模拟游标焊缝规 校准 — 长度 内部程序；使用量块和测量棒的直接法；在固定地点 (S) 长度 内部程序 使用量块和测量棒的直接法 在固定地点 (S) – 平面焊缝 – 角部焊缝 内部程序 IW/KUM/01/02","technique_zh":"内部程序；使用量块和测量棒的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块和测量棒的直接法","在固定地点 (S)"],"test_object_zh":"专用游标量具\n模拟游标焊缝规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– svary v rovině","range":"0 mm to 30 mm","cmc":"0,06 mm"},{"name":"– svary v rozích","range":"0 mm to 30 mm","cmc":"0,06 mm"}],"reference_cs":"Vnitřní postup IW/KUM/01/02","regulatory_area_cs":"Délka","search_cs":"Speciální posuvná měřidla Analogová posuvná měřidla svarů Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek a měřicích válečků; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek a měřicích válečků Ve stálé lokalitě (S) – svary v rovině – svary v rozích Vnitřní postup IW/KUM/01/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek a měřicích válečků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek a měřicích válečků","Ve stálé lokalitě (S)"],"test_object_cs":"Speciální posuvná měřidla\nAnalogová posuvná měřidla svarů"},{"_id":"2eaf0702b5299b6508ab3720","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Spoinomierze","test_object_en":"Weld gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– wysokość spoin czołowych","range":"0 mm do 15 mm","cmc":"0,06 mm"},{"name":"– wysokość spoin pachwinowych","range":"0 mm do 20 mm","cmc":"0,06 mm"},{"name":"– grubość spoin pachwinowych","range":"0 mm do 15 mm","cmc":"0,06 mm"},{"name":"– szerokość spoin czołowych","range":"0 mm do 60 mm","cmc":"0,21 mm"},{"name":"– głębokość podcięcia","range":"0 mm do 6 mm","cmc":"0,065 mm"}],"parameters_en":[{"name":"– butt weld height","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"– fillet weld height","range":"0 mm to 20 mm","cmc":"0,06 mm"},{"name":"– fillet weld throat thickness","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"– butt weld width","range":"0 mm to 60 mm","cmc":"0,21 mm"},{"name":"– undercut depth","range":"0 mm to 6 mm","cmc":"0,065 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks and measuring rollers","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– wysokość spoin czołowych 0 mm do 15 mm CMC 0,06 mm\n– wysokość spoin pachwinowych 0 mm do 20 mm CMC 0,06 mm\n– grubość spoin pachwinowych 0 mm do 15 mm CMC 0,06 mm\n– szerokość spoin czołowych 0 mm do 60 mm CMC 0,21 mm\n– głębokość podcięcia 0 mm do 6 mm CMC 0,065 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/01/02","norm_bases":["IW/KUM/01/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Spoinomierze Wzorcowanie — Długość\nZakres:\n– wysokość spoin czołowych 0 mm do 15 mm CMC 0,06 mm\n– wysokość spoin pachwinowych 0 mm do 20 mm CMC 0,06 mm\n– grubość spoin pachwinowych 0 mm do 15 mm CMC 0,06 mm\n– szerokość spoin czołowych 0 mm do 60 mm CMC 0,21 mm\n– głębokość podcięcia 0 mm do 6 mm CMC 0,065 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych oraz wałeczków pomiarowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/01/02 Spoinomierze Wzorcowanie — Dlugosc\nZakres:\n– wysokosc spoin czolowych 0 mm do 15 mm CMC 0,06 mm\n– wysokosc spoin pachwinowych 0 mm do 20 mm CMC 0,06 mm\n– grubosc spoin pachwinowych 0 mm do 15 mm CMC 0,06 mm\n– szerokosc spoin czolowych 0 mm do 60 mm CMC 0,21 mm\n– glebokosc podciecia 0 mm do 6 mm CMC 0,065 mm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych oraz waleczkow pomiarowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/01/02","search_en":"Weld gauges Calibration — Length Internal procedure; Direct method using gauge blocks and measuring rollers; At permanent location (S) Length Internal procedure Direct method using gauge blocks and measuring rollers At permanent location (S) – butt weld height – fillet weld height – fillet weld throat thickness – butt weld width – undercut depth Internal procedure IW/KUM/01/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":55,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/01/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Stumpfnahthöhe","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"– Kehlnahthöhe","range":"0 mm to 20 mm","cmc":"0,06 mm"},{"name":"– Kehlnahtdicke","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"– Stumpfnahtbreite","range":"0 mm to 60 mm","cmc":"0,21 mm"},{"name":"– Einbrandkerbentiefe","range":"0 mm to 6 mm","cmc":"0,065 mm"}],"reference_de":"Internes Verfahren IW/KUM/01/02","regulatory_area_de":"Länge","search_de":"Schweißnahtlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Parallelendmaßen und Messrollen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen und Messrollen Am festen Standort (S) – Stumpfnahthöhe – Kehlnahthöhe – Kehlnahtdicke – Stumpfnahtbreite – Einbrandkerbentiefe Internes Verfahren IW/KUM/01/02","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen und Messrollen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen und Messrollen","Am festen Standort (S)"],"test_object_de":"Schweißnahtlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 对接焊缝余高","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"– 角焊缝高度","range":"0 mm to 20 mm","cmc":"0,06 mm"},{"name":"– 角焊缝厚度","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"– 对接焊缝宽度","range":"0 mm to 60 mm","cmc":"0,21 mm"},{"name":"– 咬边深度","range":"0 mm to 6 mm","cmc":"0,065 mm"}],"reference_zh":"内部程序 IW/KUM/01/02","regulatory_area_zh":"长度","search_zh":"焊缝量规 校准 — 长度 内部程序；使用量块和测量棒的直接法；在固定地点 (S) 长度 内部程序 使用量块和测量棒的直接法 在固定地点 (S) – 对接焊缝余高 – 角焊缝高度 – 角焊缝厚度 – 对接焊缝宽度 – 咬边深度 内部程序 IW/KUM/01/02","technique_zh":"内部程序；使用量块和测量棒的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块和测量棒的直接法","在固定地点 (S)"],"test_object_zh":"焊缝量规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– výška tupých svarů","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"– výška koutových svarů","range":"0 mm to 20 mm","cmc":"0,06 mm"},{"name":"– tloušťka koutových svarů","range":"0 mm to 15 mm","cmc":"0,06 mm"},{"name":"– šířka tupých svarů","range":"0 mm to 60 mm","cmc":"0,21 mm"},{"name":"– hloubka zápalu","range":"0 mm to 6 mm","cmc":"0,065 mm"}],"reference_cs":"Vnitřní postup IW/KUM/01/02","regulatory_area_cs":"Délka","search_cs":"Svarové měrky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek a měřicích válečků; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek a měřicích válečků Ve stálé lokalitě (S) – výška tupých svarů – výška koutových svarů – tloušťka koutových svarů – šířka tupých svarů – hloubka zápalu Vnitřní postup IW/KUM/01/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek a měřicích válečků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek a měřicích válečků","Ve stálé lokalitě (S)"],"test_object_cs":"Svarové měrky"},{"_id":"59b4b19a283e1034426b563d","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Przyrządy suwmiarkowe specjalne","test_object_en":"Special vernier instruments","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"Fazomierze suwmiarkowe","range":"0 mm do 10 mm","cmc":"20 µm"},{"name":"Szczelinomierze suwmiarkowe stożkowe","range":"0,2 mm do 40 mm","cmc":"13 µm"}],"parameters_en":[{"name":"Vernier chamfer gauges","range":"0 mm to 10 mm","cmc":"20 µm"},{"name":"Taper vernier gap gauges","range":"0,2 mm to 40 mm","cmc":"13 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\nFazomierze suwmiarkowe 0 mm do 10 mm CMC 20 µm\nSzczelinomierze suwmiarkowe stożkowe 0,2 mm do 40 mm CMC 13 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/01/04","norm_bases":["IW/KUM/01/04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przyrządy suwmiarkowe specjalne Wzorcowanie — Długość\nZakres:\nFazomierze suwmiarkowe 0 mm do 10 mm CMC 20 µm\nSzczelinomierze suwmiarkowe stożkowe 0,2 mm do 40 mm CMC 13 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/01/04 Przyrzady suwmiarkowe specjalne Wzorcowanie — Dlugosc\nZakres:\nFazomierze suwmiarkowe 0 mm do 10 mm CMC 20 µm\nSzczelinomierze suwmiarkowe stozkowe 0,2 mm do 40 mm CMC 13 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/01/04","search_en":"Special vernier instruments Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Vernier chamfer gauges Taper vernier gap gauges Internal procedure IW/KUM/01/04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":56,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/01/04","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Fasenmessschieber","range":"0 mm to 10 mm","cmc":"20 µm"},{"name":"Kegelige Spaltmessschieber","range":"0,2 mm to 40 mm","cmc":"13 µm"}],"reference_de":"Internes Verfahren IW/KUM/01/04","regulatory_area_de":"Länge","search_de":"Spezialmessschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Fasenmessschieber Kegelige Spaltmessschieber Internes Verfahren IW/KUM/01/04","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Spezialmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"游标倒角规","range":"0 mm to 10 mm","cmc":"20 µm"},{"name":"锥形游标塞尺","range":"0,2 mm to 40 mm","cmc":"13 µm"}],"reference_zh":"内部程序 IW/KUM/01/04","regulatory_area_zh":"长度","search_zh":"专用游标量具 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 游标倒角规 锥形游标塞尺 内部程序 IW/KUM/01/04","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"专用游标量具","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"Posuvné měřidla zkosení","range":"0 mm to 10 mm","cmc":"20 µm"},{"name":"Kuželová posuvná spároměrka","range":"0,2 mm to 40 mm","cmc":"13 µm"}],"reference_cs":"Vnitřní postup IW/KUM/01/04","regulatory_area_cs":"Délka","search_cs":"Speciální posuvná měřidla Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Posuvné měřidla zkosení Kuželová posuvná spároměrka Vnitřní postup IW/KUM/01/04","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Speciální posuvná měřidla"},{"_id":"0825d416acdb3bb459590791","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Sprawdziany gwintowe pierścieniowe walcowe","test_object_en":"Cylindrical thread ring gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"średnica podziałowa D₂","range":"2,6 mm do 90 mm","cmc":"3,1 µm"},{"name":"średnica podziałowa D₂","range":"90 mm do 125 mm","cmc":"3,2 µm"}],"parameters_en":[{"name":"pitch diameter D₂","range":"2,6 mm to 90 mm","cmc":"3,1 µm"},{"name":"pitch diameter D₂","range":"90 mm to 125 mm","cmc":"3,2 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a ULM 520 S-E length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\nśrednica podziałowa D₂ 2,6 mm do 90 mm CMC 3,1 µm\nśrednica podziałowa D₂ 90 mm do 125 mm CMC 3,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/22/02","norm_bases":["IW/KUM/22/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe pierścieniowe walcowe Wzorcowanie — Długość\nZakres:\nśrednica podziałowa D₂ 2,6 mm do 90 mm CMC 3,1 µm\nśrednica podziałowa D₂ 90 mm do 125 mm CMC 3,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/22/02 Sprawdziany gwintowe pierscieniowe walcowe Wzorcowanie — Dlugosc\nZakres:\nsrednica podzialowa D₂ 2,6 mm do 90 mm CMC 3,1 µm\nsrednica podzialowa D₂ 90 mm do 125 mm CMC 3,2 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza ULM 520 S-E; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/22/02","search_en":"Cylindrical thread ring gauges Calibration — Length Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Length Internal procedure Direct method using a ULM 520 S-E length measuring machine At permanent location (S) pitch diameter D₂ pitch diameter D₂ Internal procedure IW/KUM/22/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":57,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/22/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Flankendurchmesser D₂","range":"2,6 mm to 90 mm","cmc":"3,1 µm"},{"name":"Flankendurchmesser D₂","range":"90 mm to 125 mm","cmc":"3,2 µm"}],"reference_de":"Internes Verfahren IW/KUM/22/02","regulatory_area_de":"Länge","search_de":"Zylindrische Gewindelehrringe Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E Am festen Standort (S) Flankendurchmesser D₂ Flankendurchmesser D₂ Internes Verfahren IW/KUM/22/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E","Am festen Standort (S)"],"test_object_de":"Zylindrische Gewindelehrringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"中径D₂","range":"2,6 mm to 90 mm","cmc":"3,1 µm"},{"name":"中径D₂","range":"90 mm to 125 mm","cmc":"3,2 µm"}],"reference_zh":"内部程序 IW/KUM/22/02","regulatory_area_zh":"长度","search_zh":"圆柱螺纹环规 校准 — 长度 内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S) 长度 内部程序 使用ULM 520 S-E测长仪的直接法 在固定地点 (S) 中径D₂ 中径D₂ 内部程序 IW/KUM/22/02","technique_zh":"内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ULM 520 S-E测长仪的直接法","在固定地点 (S)"],"test_object_zh":"圆柱螺纹环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"střední průměr D₂","range":"2,6 mm to 90 mm","cmc":"3,1 µm"},{"name":"střední průměr D₂","range":"90 mm to 125 mm","cmc":"3,2 µm"}],"reference_cs":"Vnitřní postup IW/KUM/22/02","regulatory_area_cs":"Délka","search_cs":"Závitové kroužky válcové Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru ULM 520 S-E Ve stálé lokalitě (S) střední průměr D₂ střední průměr D₂ Vnitřní postup IW/KUM/22/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru ULM 520 S-E","Ve stálé lokalitě (S)"],"test_object_cs":"Závitové kroužky válcové"},{"_id":"be21bcfa40622b6a8d210302","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Sprawdziany gwintowe trzpieniowe walcowe","test_object_en":"Cylindrical thread plug gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"średnica podziałowa d₂","range":"1 mm do 100 mm","cmc":"3,0 µm"},{"name":"średnica podziałowa d₂","range":"100 mm do 200 mm","cmc":"3,1 µm"}],"parameters_en":[{"name":"pitch diameter d₂","range":"1 mm to 100 mm","cmc":"3,0 µm"},{"name":"pitch diameter d₂","range":"100 mm to 200 mm","cmc":"3,1 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a ULM 520 S-E length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\nśrednica podziałowa d₂ 1 mm do 100 mm CMC 3,0 µm\nśrednica podziałowa d₂ 100 mm do 200 mm CMC 3,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/22/03","norm_bases":["IW/KUM/22/03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe trzpieniowe walcowe Wzorcowanie — Długość\nZakres:\nśrednica podziałowa d₂ 1 mm do 100 mm CMC 3,0 µm\nśrednica podziałowa d₂ 100 mm do 200 mm CMC 3,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/22/03 Sprawdziany gwintowe trzpieniowe walcowe Wzorcowanie — Dlugosc\nZakres:\nsrednica podzialowa d₂ 1 mm do 100 mm CMC 3,0 µm\nsrednica podzialowa d₂ 100 mm do 200 mm CMC 3,1 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza ULM 520 S-E; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/22/03","search_en":"Cylindrical thread plug gauges Calibration — Length Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Length Internal procedure Direct method using a ULM 520 S-E length measuring machine At permanent location (S) pitch diameter d₂ pitch diameter d₂ Internal procedure IW/KUM/22/03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":58,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/22/03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Flankendurchmesser d₂","range":"1 mm to 100 mm","cmc":"3,0 µm"},{"name":"Flankendurchmesser d₂","range":"100 mm to 200 mm","cmc":"3,1 µm"}],"reference_de":"Internes Verfahren IW/KUM/22/03","regulatory_area_de":"Länge","search_de":"Zylindrische Gewindelehrdorne Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E Am festen Standort (S) Flankendurchmesser d₂ Flankendurchmesser d₂ Internes Verfahren IW/KUM/22/03","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E","Am festen Standort (S)"],"test_object_de":"Zylindrische Gewindelehrdorne","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"中径d₂","range":"1 mm to 100 mm","cmc":"3,0 µm"},{"name":"中径d₂","range":"100 mm to 200 mm","cmc":"3,1 µm"}],"reference_zh":"内部程序 IW/KUM/22/03","regulatory_area_zh":"长度","search_zh":"圆柱螺纹塞规 校准 — 长度 内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S) 长度 内部程序 使用ULM 520 S-E测长仪的直接法 在固定地点 (S) 中径d₂ 中径d₂ 内部程序 IW/KUM/22/03","technique_zh":"内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ULM 520 S-E测长仪的直接法","在固定地点 (S)"],"test_object_zh":"圆柱螺纹塞规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"střední průměr d₂","range":"1 mm to 100 mm","cmc":"3,0 µm"},{"name":"střední průměr d₂","range":"100 mm to 200 mm","cmc":"3,1 µm"}],"reference_cs":"Vnitřní postup IW/KUM/22/03","regulatory_area_cs":"Délka","search_cs":"Závitové trny válcové Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru ULM 520 S-E Ve stálé lokalitě (S) střední průměr d₂ střední průměr d₂ Vnitřní postup IW/KUM/22/03","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru ULM 520 S-E","Ve stálé lokalitě (S)"],"test_object_cs":"Závitové trny válcové"},{"_id":"4b06b1c2a06e4e1cf81b421e","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Sprawdziany gwintowe pierścieniowe stożkowe","test_object_en":"Taper thread ring gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"średnica podziałowa","range":"4 mm do 100 mm","cmc":"5,0 µm"}],"parameters_en":[{"name":"pitch diameter","range":"4 mm to 100 mm","cmc":"5,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a ULM 520 S-E length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nśrednica podziałowa 4 mm do 100 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/22/05","norm_bases":["IW/KUM/22/05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe pierścieniowe stożkowe Wzorcowanie — Długość\nśrednica podziałowa 4 mm do 100 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/22/05 Sprawdziany gwintowe pierscieniowe stozkowe Wzorcowanie — Dlugosc\nsrednica podzialowa 4 mm do 100 mm CMC 5,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza ULM 520 S-E; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/22/05","search_en":"Taper thread ring gauges Calibration — Length Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Length Internal procedure Direct method using a ULM 520 S-E length measuring machine At permanent location (S) pitch diameter Internal procedure IW/KUM/22/05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":59,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/22/05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Flankendurchmesser","range":"4 mm to 100 mm","cmc":"5,0 µm"}],"reference_de":"Internes Verfahren IW/KUM/22/05","regulatory_area_de":"Länge","search_de":"Kegelige Gewindelehrringe Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E Am festen Standort (S) Flankendurchmesser Internes Verfahren IW/KUM/22/05","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E","Am festen Standort (S)"],"test_object_de":"Kegelige Gewindelehrringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"中径","range":"4 mm to 100 mm","cmc":"5,0 µm"}],"reference_zh":"内部程序 IW/KUM/22/05","regulatory_area_zh":"长度","search_zh":"锥度螺纹环规 校准 — 长度 内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S) 长度 内部程序 使用ULM 520 S-E测长仪的直接法 在固定地点 (S) 中径 内部程序 IW/KUM/22/05","technique_zh":"内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ULM 520 S-E测长仪的直接法","在固定地点 (S)"],"test_object_zh":"锥度螺纹环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"střední průměr","range":"4 mm to 100 mm","cmc":"5,0 µm"}],"reference_cs":"Vnitřní postup IW/KUM/22/05","regulatory_area_cs":"Délka","search_cs":"Kuželové závitové kroužky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru ULM 520 S-E Ve stálé lokalitě (S) střední průměr Vnitřní postup IW/KUM/22/05","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru ULM 520 S-E","Ve stálé lokalitě (S)"],"test_object_cs":"Kuželové závitové kroužky"},{"_id":"f98489013650b49e0e16a181","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Sprawdziany gwintowe trzpieniowe stożkowe","test_object_en":"Taper thread plug gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"średnica podziałowa","range":"4 mm do 100 mm","cmc":"5,0 µm"}],"parameters_en":[{"name":"pitch diameter","range":"4 mm to 100 mm","cmc":"5,0 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a ULM 520 S-E length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nśrednica podziałowa 4 mm do 100 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/22/06","norm_bases":["IW/KUM/22/06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe trzpieniowe stożkowe Wzorcowanie — Długość\nśrednica podziałowa 4 mm do 100 mm CMC 5,0 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/22/06 Sprawdziany gwintowe trzpieniowe stozkowe Wzorcowanie — Dlugosc\nsrednica podzialowa 4 mm do 100 mm CMC 5,0 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza ULM 520 S-E; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/22/06","search_en":"Taper thread plug gauges Calibration — Length Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Length Internal procedure Direct method using a ULM 520 S-E length measuring machine At permanent location (S) pitch diameter Internal procedure IW/KUM/22/06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":60,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/22/06","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Flankendurchmesser","range":"4 mm to 100 mm","cmc":"5,0 µm"}],"reference_de":"Internes Verfahren IW/KUM/22/06","regulatory_area_de":"Länge","search_de":"Kegelige Gewindelehrdorne Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E Am festen Standort (S) Flankendurchmesser Internes Verfahren IW/KUM/22/06","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E","Am festen Standort (S)"],"test_object_de":"Kegelige Gewindelehrdorne","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"中径","range":"4 mm to 100 mm","cmc":"5,0 µm"}],"reference_zh":"内部程序 IW/KUM/22/06","regulatory_area_zh":"长度","search_zh":"锥度螺纹塞规 校准 — 长度 内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S) 长度 内部程序 使用ULM 520 S-E测长仪的直接法 在固定地点 (S) 中径 内部程序 IW/KUM/22/06","technique_zh":"内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ULM 520 S-E测长仪的直接法","在固定地点 (S)"],"test_object_zh":"锥度螺纹塞规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"střední průměr","range":"4 mm to 100 mm","cmc":"5,0 µm"}],"reference_cs":"Vnitřní postup IW/KUM/22/06","regulatory_area_cs":"Délka","search_cs":"Kuželové závitové kalibry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru ULM 520 S-E Ve stálé lokalitě (S) střední průměr Vnitřní postup IW/KUM/22/06","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru ULM 520 S-E","Ve stálé lokalitě (S)"],"test_object_cs":"Kuželové závitové kalibry"},{"_id":"952d31121d404867341510a9","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Sprawdziany pierścieniowe gładkie:","test_object_en":"Plain ring gauges:","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– za pomocą głowicy","range":"3 mm do 50 mm","cmc":"0,7 µm"},{"name":"– za pomocą głowicy","range":"50 mm do 90 mm","cmc":"0,8 µm"},{"name":"– za pomocą kabłąków","range":"12 mm do 50 mm","cmc":"0,6 µm"},{"name":"– za pomocą kabłąków","range":"50 mm do 100 mm","cmc":"0,7 µm"},{"name":"– za pomocą kabłąków","range":"100 mm do 150 mm","cmc":"1,0 µm"},{"name":"– za pomocą kabłąków","range":"150 mm do 200 mm","cmc":"1,4 µm"},{"name":"– za pomocą kabłąków","range":"200 mm do 250 mm","cmc":"1,8 µm"},{"name":"– za pomocą kabłąków","range":"250 mm do 300 mm","cmc":"2,3 µm"}],"parameters_en":[{"name":"– with the head","range":"3 mm to 50 mm","cmc":"0,7 µm"},{"name":"– with the head","range":"50 mm to 90 mm","cmc":"0,8 µm"},{"name":"– with the bows","range":"12 mm to 50 mm","cmc":"0,6 µm"},{"name":"– with the bows","range":"50 mm to 100 mm","cmc":"0,7 µm"},{"name":"– with the bows","range":"100 mm to 150 mm","cmc":"1,0 µm"},{"name":"– with the bows","range":"150 mm to 200 mm","cmc":"1,4 µm"},{"name":"– with the bows","range":"200 mm to 250 mm","cmc":"1,8 µm"},{"name":"– with the bows","range":"250 mm to 300 mm","cmc":"2,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a ULM 520 S-E length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– za pomocą głowicy 3 mm do 50 mm CMC 0,7 µm\n– za pomocą głowicy 50 mm do 90 mm CMC 0,8 µm\n– za pomocą kabłąków 12 mm do 50 mm CMC 0,6 µm\n– za pomocą kabłąków 50 mm do 100 mm CMC 0,7 µm\n– za pomocą kabłąków 100 mm do 150 mm CMC 1,0 µm\n– za pomocą kabłąków 150 mm do 200 mm CMC 1,4 µm\n– za pomocą kabłąków 200 mm do 250 mm CMC 1,8 µm\n– za pomocą kabłąków 250 mm do 300 mm CMC 2,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/22/01","norm_bases":["IW/KUM/22/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany pierścieniowe gładkie: Wzorcowanie — Długość\nZakres:\n– za pomocą głowicy 3 mm do 50 mm CMC 0,7 µm\n– za pomocą głowicy 50 mm do 90 mm CMC 0,8 µm\n– za pomocą kabłąków 12 mm do 50 mm CMC 0,6 µm\n– za pomocą kabłąków 50 mm do 100 mm CMC 0,7 µm\n– za pomocą kabłąków 100 mm do 150 mm CMC 1,0 µm\n– za pomocą kabłąków 150 mm do 200 mm CMC 1,4 µm\n– za pomocą kabłąków 200 mm do 250 mm CMC 1,8 µm\n– za pomocą kabłąków 250 mm do 300 mm CMC 2,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/22/01 Sprawdziany pierscieniowe gladkie: Wzorcowanie — Dlugosc\nZakres:\n– za pomoca glowicy 3 mm do 50 mm CMC 0,7 µm\n– za pomoca glowicy 50 mm do 90 mm CMC 0,8 µm\n– za pomoca kablakow 12 mm do 50 mm CMC 0,6 µm\n– za pomoca kablakow 50 mm do 100 mm CMC 0,7 µm\n– za pomoca kablakow 100 mm do 150 mm CMC 1,0 µm\n– za pomoca kablakow 150 mm do 200 mm CMC 1,4 µm\n– za pomoca kablakow 200 mm do 250 mm CMC 1,8 µm\n– za pomoca kablakow 250 mm do 300 mm CMC 2,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza ULM 520 S-E; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/22/01","search_en":"Plain ring gauges: Calibration — Length Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Length Internal procedure Direct method using a ULM 520 S-E length measuring machine At permanent location (S) – with the head – with the head – with the bows – with the bows – with the bows – with the bows – with the bows – with the bows Internal procedure IW/KUM/22/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":61,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/22/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– mit dem Messkopf","range":"3 mm to 50 mm","cmc":"0,7 µm"},{"name":"– mit dem Messkopf","range":"50 mm to 90 mm","cmc":"0,8 µm"},{"name":"– mit Messbügeln","range":"12 mm to 50 mm","cmc":"0,6 µm"},{"name":"– mit Messbügeln","range":"50 mm to 100 mm","cmc":"0,7 µm"},{"name":"– mit Messbügeln","range":"100 mm to 150 mm","cmc":"1,0 µm"},{"name":"– mit Messbügeln","range":"150 mm to 200 mm","cmc":"1,4 µm"},{"name":"– mit Messbügeln","range":"200 mm to 250 mm","cmc":"1,8 µm"},{"name":"– mit Messbügeln","range":"250 mm to 300 mm","cmc":"2,3 µm"}],"reference_de":"Internes Verfahren IW/KUM/22/01","regulatory_area_de":"Länge","search_de":"Glatte Lehrringe: Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E Am festen Standort (S) – mit dem Messkopf – mit dem Messkopf – mit Messbügeln – mit Messbügeln – mit Messbügeln – mit Messbügeln – mit Messbügeln – mit Messbügeln Internes Verfahren IW/KUM/22/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E","Am festen Standort (S)"],"test_object_de":"Glatte Lehrringe:","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 用测头","range":"3 mm to 50 mm","cmc":"0,7 µm"},{"name":"– 用测头","range":"50 mm to 90 mm","cmc":"0,8 µm"},{"name":"– 用测量臂","range":"12 mm to 50 mm","cmc":"0,6 µm"},{"name":"– 用测量臂","range":"50 mm to 100 mm","cmc":"0,7 µm"},{"name":"– 用测量臂","range":"100 mm to 150 mm","cmc":"1,0 µm"},{"name":"– 用测量臂","range":"150 mm to 200 mm","cmc":"1,4 µm"},{"name":"– 用测量臂","range":"200 mm to 250 mm","cmc":"1,8 µm"},{"name":"– 用测量臂","range":"250 mm to 300 mm","cmc":"2,3 µm"}],"reference_zh":"内部程序 IW/KUM/22/01","regulatory_area_zh":"长度","search_zh":"光滑环规： 校准 — 长度 内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S) 长度 内部程序 使用ULM 520 S-E测长仪的直接法 在固定地点 (S) – 用测头 – 用测头 – 用测量臂 – 用测量臂 – 用测量臂 – 用测量臂 – 用测量臂 – 用测量臂 内部程序 IW/KUM/22/01","technique_zh":"内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ULM 520 S-E测长仪的直接法","在固定地点 (S)"],"test_object_zh":"光滑环规：","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– pomocí hlavice","range":"3 mm to 50 mm","cmc":"0,7 µm"},{"name":"– pomocí hlavice","range":"50 mm to 90 mm","cmc":"0,8 µm"},{"name":"– pomocí třmenů","range":"12 mm to 50 mm","cmc":"0,6 µm"},{"name":"– pomocí třmenů","range":"50 mm to 100 mm","cmc":"0,7 µm"},{"name":"– pomocí třmenů","range":"100 mm to 150 mm","cmc":"1,0 µm"},{"name":"– pomocí třmenů","range":"150 mm to 200 mm","cmc":"1,4 µm"},{"name":"– pomocí třmenů","range":"200 mm to 250 mm","cmc":"1,8 µm"},{"name":"– pomocí třmenů","range":"250 mm to 300 mm","cmc":"2,3 µm"}],"reference_cs":"Vnitřní postup IW/KUM/22/01","regulatory_area_cs":"Délka","search_cs":"Hladké kroužky: Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru ULM 520 S-E Ve stálé lokalitě (S) – pomocí hlavice – pomocí hlavice – pomocí třmenů – pomocí třmenů – pomocí třmenů – pomocí třmenů – pomocí třmenů – pomocí třmenů Vnitřní postup IW/KUM/22/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru ULM 520 S-E","Ve stálé lokalitě (S)"],"test_object_cs":"Hladké kroužky:"},{"_id":"ec0fc4ad0d9e6088781570e6","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Sprawdziany stożkowe do otworów","test_object_en":"Taper hole gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,1 mm do 5 mm","cmc":"9 µm"},{"name":"","range":"1 mm do 60 mm","cmc":"17 µm"}],"parameters_en":[{"name":"","range":"0,1 mm to 5 mm","cmc":"9 µm"},{"name":"","range":"1 mm to 60 mm","cmc":"17 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an ISD-V300A microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an ISD-V300A microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0,1 mm do 5 mm CMC 9 µm\n1 mm do 60 mm CMC 17 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/23/02","norm_bases":["IW/KUM/23/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany stożkowe do otworów Wzorcowanie — Długość\nZakres:\n0,1 mm do 5 mm CMC 9 µm\n1 mm do 60 mm CMC 17 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/23/02 Sprawdziany stozkowe do otworow Wzorcowanie — Dlugosc\nZakres:\n0,1 mm do 5 mm CMC 9 µm\n1 mm do 60 mm CMC 17 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem mikroskopu ISD-V300A; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/23/02","search_en":"Taper hole gauges Calibration — Length Internal procedure; Direct method using an ISD-V300A microscope; At permanent location (S) Length Internal procedure Direct method using an ISD-V300A microscope At permanent location (S) Internal procedure IW/KUM/23/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":62,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/23/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,1 mm to 5 mm","cmc":"9 µm"},{"name":"","range":"1 mm to 60 mm","cmc":"17 µm"}],"reference_de":"Internes Verfahren IW/KUM/23/02","regulatory_area_de":"Länge","search_de":"Kegellehren für Bohrungen Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Mikroskop ISD-V300A; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Mikroskop ISD-V300A Am festen Standort (S) Internes Verfahren IW/KUM/23/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Mikroskop ISD-V300A; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Mikroskop ISD-V300A","Am festen Standort (S)"],"test_object_de":"Kegellehren für Bohrungen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,1 mm to 5 mm","cmc":"9 µm"},{"name":"","range":"1 mm to 60 mm","cmc":"17 µm"}],"reference_zh":"内部程序 IW/KUM/23/02","regulatory_area_zh":"长度","search_zh":"孔用锥度量规 校准 — 长度 内部程序；使用ISD-V300A显微镜的直接法；在固定地点 (S) 长度 内部程序 使用ISD-V300A显微镜的直接法 在固定地点 (S) 内部程序 IW/KUM/23/02","technique_zh":"内部程序；使用ISD-V300A显微镜的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ISD-V300A显微镜的直接法","在固定地点 (S)"],"test_object_zh":"孔用锥度量规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,1 mm to 5 mm","cmc":"9 µm"},{"name":"","range":"1 mm to 60 mm","cmc":"17 µm"}],"reference_cs":"Vnitřní postup IW/KUM/23/02","regulatory_area_cs":"Délka","search_cs":"Kuželové kalibry pro otvory Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím mikroskopu ISD-V300A; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím mikroskopu ISD-V300A Ve stálé lokalitě (S) Vnitřní postup IW/KUM/23/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím mikroskopu ISD-V300A; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím mikroskopu ISD-V300A","Ve stálé lokalitě (S)"],"test_object_cs":"Kuželové kalibry pro otvory"},{"_id":"eb4b63257490dd25ec0204fe","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Sprawdziany tłoczkowe","test_object_en":"Plug gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"1 mm do 50 mm","cmc":"0,5 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,9 µm"}],"parameters_en":[{"name":"","range":"1 mm to 50 mm","cmc":"0,5 µm"},{"name":"","range":"50 mm to 100 mm","cmc":"0,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an Abbe P01 vertical length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n1 mm do 50 mm CMC 0,5 µm\n50 mm do 100 mm CMC 0,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/07/02","norm_bases":["IW/KUM/07/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany tłoczkowe Wzorcowanie — Długość\nZakres:\n1 mm do 50 mm CMC 0,5 µm\n50 mm do 100 mm CMC 0,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/07/02 Sprawdziany tloczkowe Wzorcowanie — Dlugosc\nZakres:\n1 mm do 50 mm CMC 0,5 µm\n50 mm do 100 mm CMC 0,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza pionowego Abbego P01; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/07/02","search_en":"Plug gauges Calibration — Length Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S) Length Internal procedure Direct method using an Abbe P01 vertical length measuring machine At permanent location (S) Internal procedure IW/KUM/07/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":63,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/07/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"1 mm to 50 mm","cmc":"0,5 µm"},{"name":"","range":"50 mm to 100 mm","cmc":"0,9 µm"}],"reference_de":"Internes Verfahren IW/KUM/07/02","regulatory_area_de":"Länge","search_de":"Lehrdorne Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01 Am festen Standort (S) Internes Verfahren IW/KUM/07/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01","Am festen Standort (S)"],"test_object_de":"Lehrdorne","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"1 mm to 50 mm","cmc":"0,5 µm"},{"name":"","range":"50 mm to 100 mm","cmc":"0,9 µm"}],"reference_zh":"内部程序 IW/KUM/07/02","regulatory_area_zh":"长度","search_zh":"塞规 校准 — 长度 内部程序；使用阿贝立式测长仪P01的直接法；在固定地点 (S) 长度 内部程序 使用阿贝立式测长仪P01的直接法 在固定地点 (S) 内部程序 IW/KUM/07/02","technique_zh":"内部程序；使用阿贝立式测长仪P01的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用阿贝立式测长仪P01的直接法","在固定地点 (S)"],"test_object_zh":"塞规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"1 mm to 50 mm","cmc":"0,5 µm"},{"name":"","range":"50 mm to 100 mm","cmc":"0,9 µm"}],"reference_cs":"Vnitřní postup IW/KUM/07/02","regulatory_area_cs":"Délka","search_cs":"Kalibry trny Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím Abbeho svislého délkoměru P01; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím Abbeho svislého délkoměru P01 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/07/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím Abbeho svislého délkoměru P01; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím Abbeho svislého délkoměru P01","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibry trny"},{"_id":"d9b3f5701346760153076b5b","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Sprawdziany tłoczkowe","test_object_en":"Plug gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"1 mm do 50 mm","cmc":"0,4 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,8 µm"}],"parameters_en":[{"name":"","range":"1 mm to 50 mm","cmc":"0,4 µm"},{"name":"","range":"50 mm to 100 mm","cmc":"0,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego ULM 520 S-E; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a ULM 520 S-E horizontal length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza poziomego ULM 520 S-E","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a ULM 520 S-E horizontal length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n1 mm do 50 mm CMC 0,4 µm\n50 mm do 100 mm CMC 0,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego ULM 520 S-E; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/07/02","norm_bases":["IW/KUM/07/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany tłoczkowe Wzorcowanie — Długość\nZakres:\n1 mm do 50 mm CMC 0,4 µm\n50 mm do 100 mm CMC 0,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego ULM 520 S-E; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/07/02 Sprawdziany tloczkowe Wzorcowanie — Dlugosc\nZakres:\n1 mm do 50 mm CMC 0,4 µm\n50 mm do 100 mm CMC 0,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza poziomego ULM 520 S-E; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/07/02","search_en":"Plug gauges Calibration — Length Internal procedure; Direct method using a ULM 520 S-E horizontal length measuring machine; At permanent location (S) Length Internal procedure Direct method using a ULM 520 S-E horizontal length measuring machine At permanent location (S) Internal procedure IW/KUM/07/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":64,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/07/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"1 mm to 50 mm","cmc":"0,4 µm"},{"name":"","range":"50 mm to 100 mm","cmc":"0,8 µm"}],"reference_de":"Internes Verfahren IW/KUM/07/02","regulatory_area_de":"Länge","search_de":"Lehrdorne Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Horizontal-Längenmessgerät ULM 520 S-E; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Horizontal-Längenmessgerät ULM 520 S-E Am festen Standort (S) Internes Verfahren IW/KUM/07/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Horizontal-Längenmessgerät ULM 520 S-E; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Horizontal-Längenmessgerät ULM 520 S-E","Am festen Standort (S)"],"test_object_de":"Lehrdorne","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"1 mm to 50 mm","cmc":"0,4 µm"},{"name":"","range":"50 mm to 100 mm","cmc":"0,8 µm"}],"reference_zh":"内部程序 IW/KUM/07/02","regulatory_area_zh":"长度","search_zh":"塞规 校准 — 长度 内部程序；使用ULM 520 S-E卧式测长仪的直接法；在固定地点 (S) 长度 内部程序 使用ULM 520 S-E卧式测长仪的直接法 在固定地点 (S) 内部程序 IW/KUM/07/02","technique_zh":"内部程序；使用ULM 520 S-E卧式测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ULM 520 S-E卧式测长仪的直接法","在固定地点 (S)"],"test_object_zh":"塞规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"1 mm to 50 mm","cmc":"0,4 µm"},{"name":"","range":"50 mm to 100 mm","cmc":"0,8 µm"}],"reference_cs":"Vnitřní postup IW/KUM/07/02","regulatory_area_cs":"Délka","search_cs":"Kalibry trny Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím vodorovného délkoměru ULM 520 S-E; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím vodorovného délkoměru ULM 520 S-E Ve stálé lokalitě (S) Vnitřní postup IW/KUM/07/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím vodorovného délkoměru ULM 520 S-E; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím vodorovného délkoměru ULM 520 S-E","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibry trny"},{"_id":"04db8434072d3b40255be055","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Suwmiarki","test_object_en":"Vernier calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 150 mm","cmc":"8 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"16 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"18 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"23 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"29 µm"}],"parameters_en":[{"name":"","range":"0 mm do 150 mm","cmc":"8 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"16 µm"},{"name":"","range":"0 mm to 600 mm","cmc":"18 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"23 µm"},{"name":"","range":"0 mm to 1000 mm","cmc":"29 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 8 µm\n0 mm do 300 mm CMC 11 µm\n0 mm do 500 mm CMC 16 µm\n0 mm do 600 mm CMC 18 µm\n0 mm do 800 mm CMC 23 µm\n0 mm do 1000 mm CMC 29 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/01/01","norm_bases":["IW/KUM/01/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Suwmiarki Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 8 µm\n0 mm do 300 mm CMC 11 µm\n0 mm do 500 mm CMC 16 µm\n0 mm do 600 mm CMC 18 µm\n0 mm do 800 mm CMC 23 µm\n0 mm do 1000 mm CMC 29 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/01/01 Suwmiarki Wzorcowanie — Dlugosc\nZakres:\n0 mm do 150 mm CMC 8 µm\n0 mm do 300 mm CMC 11 µm\n0 mm do 500 mm CMC 16 µm\n0 mm do 600 mm CMC 18 µm\n0 mm do 800 mm CMC 23 µm\n0 mm do 1000 mm CMC 29 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/01/01","search_en":"Vernier calipers Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/01/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":65,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/01/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 150 mm","cmc":"8 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"16 µm"},{"name":"","range":"0 mm bis 600 mm","cmc":"18 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"23 µm"},{"name":"","range":"0 mm bis 1000 mm","cmc":"29 µm"}],"reference_de":"Internes Verfahren IW/KUM/01/01","regulatory_area_de":"Länge","search_de":"Messschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/01/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Messschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 150 mm","cmc":"8 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"16 µm"},{"name":"","range":"0 mm 至 600 mm","cmc":"18 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"23 µm"},{"name":"","range":"0 mm 至 1000 mm","cmc":"29 µm"}],"reference_zh":"内部程序 IW/KUM/01/01","regulatory_area_zh":"长度","search_zh":"游标卡尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/01/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 150 mm","cmc":"8 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"16 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"18 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"23 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"29 µm"}],"reference_cs":"Vnitřní postup IW/KUM/01/01","regulatory_area_cs":"Délka","search_cs":"Posuvná měřidla Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/01/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvná měřidla"},{"_id":"0571fb7a65d57806a36a6297","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Szczelinomierze","test_object_en":"Feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– listkowe","range":"0,02 mm do 3,0 mm","cmc":"0,3 µm"}],"parameters_en":[{"name":"– leaf","range":"0,02 mm to 3,0 mm","cmc":"0,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an Abbe P01 vertical length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n– listkowe 0,02 mm do 3,0 mm CMC 0,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/07/01","norm_bases":["IW/KUM/07/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze Wzorcowanie — Długość\n– listkowe 0,02 mm do 3,0 mm CMC 0,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/07/01 Szczelinomierze Wzorcowanie — Dlugosc\n– listkowe 0,02 mm do 3,0 mm CMC 0,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza pionowego Abbego P01; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/07/01","search_en":"Feeler gauges Calibration — Length Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S) Length Internal procedure Direct method using an Abbe P01 vertical length measuring machine At permanent location (S) – leaf Internal procedure IW/KUM/07/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":66,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/07/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Blattform","range":"0,02 mm to 3,0 mm","cmc":"0,3 µm"}],"reference_de":"Internes Verfahren IW/KUM/07/01","regulatory_area_de":"Länge","search_de":"Fühlerlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01 Am festen Standort (S) – Blattform Internes Verfahren IW/KUM/07/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01","Am festen Standort (S)"],"test_object_de":"Fühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 片式","range":"0,02 mm to 3,0 mm","cmc":"0,3 µm"}],"reference_zh":"内部程序 IW/KUM/07/01","regulatory_area_zh":"长度","search_zh":"塞尺 校准 — 长度 内部程序；使用阿贝立式测长仪P01的直接法；在固定地点 (S) 长度 内部程序 使用阿贝立式测长仪P01的直接法 在固定地点 (S) – 片式 内部程序 IW/KUM/07/01","technique_zh":"内部程序；使用阿贝立式测长仪P01的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用阿贝立式测长仪P01的直接法","在固定地点 (S)"],"test_object_zh":"塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– listové","range":"0,02 mm to 3,0 mm","cmc":"0,3 µm"}],"reference_cs":"Vnitřní postup IW/KUM/07/01","regulatory_area_cs":"Délka","search_cs":"Spároměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím Abbeho svislého délkoměru P01; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím Abbeho svislého délkoměru P01 Ve stálé lokalitě (S) – listové Vnitřní postup IW/KUM/07/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím Abbeho svislého délkoměru P01; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím Abbeho svislého délkoměru P01","Ve stálé lokalitě (S)"],"test_object_cs":"Spároměry"},{"_id":"48b9aa549f8eea848ee71944","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Szczelinomierze","test_object_en":"Feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– listkowe","range":"0,02 mm do 3,0 mm","cmc":"0,8 µm"}],"parameters_en":[{"name":"– leaf","range":"0,02 mm to 3,0 mm","cmc":"0,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometru cyfrowego o rozdz. 0,0001 mm; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a digital micrometer with 0,0001 mm resolution; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem mikrometru cyfrowego o rozdz. 0,0001 mm","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a digital micrometer with 0,0001 mm resolution","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n– listkowe 0,02 mm do 3,0 mm CMC 0,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometru cyfrowego o rozdz. 0,0001 mm; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/07/01","norm_bases":["IW/KUM/07/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze Wzorcowanie — Długość\n– listkowe 0,02 mm do 3,0 mm CMC 0,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometru cyfrowego o rozdz. 0,0001 mm; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/07/01 Szczelinomierze Wzorcowanie — Dlugosc\n– listkowe 0,02 mm do 3,0 mm CMC 0,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem mikrometru cyfrowego o rozdz. 0,0001 mm; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/07/01","search_en":"Feeler gauges Calibration — Length Internal procedure; Direct method using a digital micrometer with 0,0001 mm resolution; At permanent location (S) Length Internal procedure Direct method using a digital micrometer with 0,0001 mm resolution At permanent location (S) – leaf Internal procedure IW/KUM/07/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":67,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/07/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Blattform","range":"0,02 mm to 3,0 mm","cmc":"0,8 µm"}],"reference_de":"Internes Verfahren IW/KUM/07/01","regulatory_area_de":"Länge","search_de":"Fühlerlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einer digitalen Messschraube mit Auflösung 0,0001 mm; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einer digitalen Messschraube mit Auflösung 0,0001 mm Am festen Standort (S) – Blattform Internes Verfahren IW/KUM/07/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einer digitalen Messschraube mit Auflösung 0,0001 mm; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einer digitalen Messschraube mit Auflösung 0,0001 mm","Am festen Standort (S)"],"test_object_de":"Fühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 片式","range":"0,02 mm to 3,0 mm","cmc":"0,8 µm"}],"reference_zh":"内部程序 IW/KUM/07/01","regulatory_area_zh":"长度","search_zh":"塞尺 校准 — 长度 内部程序；使用分辨力0,0001 mm数显千分尺的直接法；在固定地点 (S) 长度 内部程序 使用分辨力0,0001 mm数显千分尺的直接法 在固定地点 (S) – 片式 内部程序 IW/KUM/07/01","technique_zh":"内部程序；使用分辨力0,0001 mm数显千分尺的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用分辨力0,0001 mm数显千分尺的直接法","在固定地点 (S)"],"test_object_zh":"塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– listové","range":"0,02 mm to 3,0 mm","cmc":"0,8 µm"}],"reference_cs":"Vnitřní postup IW/KUM/07/01","regulatory_area_cs":"Délka","search_cs":"Spároměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím digitálního mikrometru s rozlišením 0,0001 mm; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím digitálního mikrometru s rozlišením 0,0001 mm Ve stálé lokalitě (S) – listové Vnitřní postup IW/KUM/07/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím digitálního mikrometru s rozlišením 0,0001 mm; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím digitálního mikrometru s rozlišením 0,0001 mm","Ve stálé lokalitě (S)"],"test_object_cs":"Spároměry"},{"_id":"2cdd3ba11e8fac78bbb150bb","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Szczelinomierze","test_object_en":"Feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– klinowe szerokie","range":"0,5 mm do 27 mm","cmc":"12 µm"}],"parameters_en":[{"name":"– wide wedge","range":"0,5 mm to 27 mm","cmc":"12 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an Abbe P01 vertical length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n– klinowe szerokie 0,5 mm do 27 mm CMC 12 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/07/01","norm_bases":["IW/KUM/07/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze Wzorcowanie — Długość\n– klinowe szerokie 0,5 mm do 27 mm CMC 12 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/07/01 Szczelinomierze Wzorcowanie — Dlugosc\n– klinowe szerokie 0,5 mm do 27 mm CMC 12 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza pionowego Abbego P01; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/07/01","search_en":"Feeler gauges Calibration — Length Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S) Length Internal procedure Direct method using an Abbe P01 vertical length measuring machine At permanent location (S) – wide wedge Internal procedure IW/KUM/07/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":68,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/07/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– breite Keilform","range":"0,5 mm to 27 mm","cmc":"12 µm"}],"reference_de":"Internes Verfahren IW/KUM/07/01","regulatory_area_de":"Länge","search_de":"Fühlerlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01 Am festen Standort (S) – breite Keilform Internes Verfahren IW/KUM/07/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01","Am festen Standort (S)"],"test_object_de":"Fühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 宽楔形","range":"0,5 mm to 27 mm","cmc":"12 µm"}],"reference_zh":"内部程序 IW/KUM/07/01","regulatory_area_zh":"长度","search_zh":"塞尺 校准 — 长度 内部程序；使用阿贝立式测长仪P01的直接法；在固定地点 (S) 长度 内部程序 使用阿贝立式测长仪P01的直接法 在固定地点 (S) – 宽楔形 内部程序 IW/KUM/07/01","technique_zh":"内部程序；使用阿贝立式测长仪P01的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用阿贝立式测长仪P01的直接法","在固定地点 (S)"],"test_object_zh":"塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– klínové široké","range":"0,5 mm to 27 mm","cmc":"12 µm"}],"reference_cs":"Vnitřní postup IW/KUM/07/01","regulatory_area_cs":"Délka","search_cs":"Spároměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím Abbeho svislého délkoměru P01; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím Abbeho svislého délkoměru P01 Ve stálé lokalitě (S) – klínové široké Vnitřní postup IW/KUM/07/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím Abbeho svislého délkoměru P01; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím Abbeho svislého délkoměru P01","Ve stálé lokalitě (S)"],"test_object_cs":"Spároměry"},{"_id":"39edae828983b91471c81205","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Szczelinomierze","test_object_en":"Feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– klinowe szerokie","range":"0,5 mm do 27 mm","cmc":"14 µm"}],"parameters_en":[{"name":"– wide wedge","range":"0,5 mm to 27 mm","cmc":"14 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem czujnika cyfrowego o rozdz. 0,0005 mm; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a digital dial gauge with 0,0005 mm resolution; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem czujnika cyfrowego o rozdz. 0,0005 mm","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a digital dial gauge with 0,0005 mm resolution","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n– klinowe szerokie 0,5 mm do 27 mm CMC 14 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem czujnika cyfrowego o rozdz. 0,0005 mm; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/07/01","norm_bases":["IW/KUM/07/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze Wzorcowanie — Długość\n– klinowe szerokie 0,5 mm do 27 mm CMC 14 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem czujnika cyfrowego o rozdz. 0,0005 mm; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/07/01 Szczelinomierze Wzorcowanie — Dlugosc\n– klinowe szerokie 0,5 mm do 27 mm CMC 14 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem czujnika cyfrowego o rozdz. 0,0005 mm; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/07/01","search_en":"Feeler gauges Calibration — Length Internal procedure; Direct method using a digital dial gauge with 0,0005 mm resolution; At permanent location (S) Length Internal procedure Direct method using a digital dial gauge with 0,0005 mm resolution At permanent location (S) – wide wedge Internal procedure IW/KUM/07/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":69,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/07/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– breite Keilform","range":"0,5 mm to 27 mm","cmc":"14 µm"}],"reference_de":"Internes Verfahren IW/KUM/07/01","regulatory_area_de":"Länge","search_de":"Fühlerlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einer digitalen Messuhr mit Auflösung 0,0005 mm; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einer digitalen Messuhr mit Auflösung 0,0005 mm Am festen Standort (S) – breite Keilform Internes Verfahren IW/KUM/07/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einer digitalen Messuhr mit Auflösung 0,0005 mm; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einer digitalen Messuhr mit Auflösung 0,0005 mm","Am festen Standort (S)"],"test_object_de":"Fühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 宽楔形","range":"0,5 mm to 27 mm","cmc":"14 µm"}],"reference_zh":"内部程序 IW/KUM/07/01","regulatory_area_zh":"长度","search_zh":"塞尺 校准 — 长度 内部程序；使用分辨力0,0005 mm数显指示表的直接法；在固定地点 (S) 长度 内部程序 使用分辨力0,0005 mm数显指示表的直接法 在固定地点 (S) – 宽楔形 内部程序 IW/KUM/07/01","technique_zh":"内部程序；使用分辨力0,0005 mm数显指示表的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用分辨力0,0005 mm数显指示表的直接法","在固定地点 (S)"],"test_object_zh":"塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– klínové široké","range":"0,5 mm to 27 mm","cmc":"14 µm"}],"reference_cs":"Vnitřní postup IW/KUM/07/01","regulatory_area_cs":"Délka","search_cs":"Spároměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím digitálního úchylkoměru s rozlišením 0,0005 mm; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím digitálního úchylkoměru s rozlišením 0,0005 mm Ve stálé lokalitě (S) – klínové široké Vnitřní postup IW/KUM/07/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím digitálního úchylkoměru s rozlišením 0,0005 mm; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím digitálního úchylkoměru s rozlišením 0,0005 mm","Ve stálé lokalitě (S)"],"test_object_cs":"Spároměry"},{"_id":"3304ab3db3fa7dc3b737c517","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Szczelinomierze","test_object_en":"Feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– klinowe – klin płaski","range":"0,5 mm do 45 mm","cmc":"8 µm"}],"parameters_en":[{"name":"– wedge – flat wedge","range":"0,5 mm to 45 mm","cmc":"8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu pomiarowego cyfrowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a digital measuring microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem mikroskopu pomiarowego cyfrowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a digital measuring microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n– klinowe – klin płaski 0,5 mm do 45 mm CMC 8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu pomiarowego cyfrowego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/07/01","norm_bases":["IW/KUM/07/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze Wzorcowanie — Długość\n– klinowe – klin płaski 0,5 mm do 45 mm CMC 8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu pomiarowego cyfrowego; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/07/01 Szczelinomierze Wzorcowanie — Dlugosc\n– klinowe – klin plaski 0,5 mm do 45 mm CMC 8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem mikroskopu pomiarowego cyfrowego; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/07/01","search_en":"Feeler gauges Calibration — Length Internal procedure; Direct method using a digital measuring microscope; At permanent location (S) Length Internal procedure Direct method using a digital measuring microscope At permanent location (S) – wedge – flat wedge Internal procedure IW/KUM/07/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":70,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/07/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Keilform – flacher Keil","range":"0,5 mm to 45 mm","cmc":"8 µm"}],"reference_de":"Internes Verfahren IW/KUM/07/01","regulatory_area_de":"Länge","search_de":"Fühlerlehren Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem digitalen Messmikroskop; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem digitalen Messmikroskop Am festen Standort (S) – Keilform – flacher Keil Internes Verfahren IW/KUM/07/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem digitalen Messmikroskop; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem digitalen Messmikroskop","Am festen Standort (S)"],"test_object_de":"Fühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 楔形 – 扁楔","range":"0,5 mm to 45 mm","cmc":"8 µm"}],"reference_zh":"内部程序 IW/KUM/07/01","regulatory_area_zh":"长度","search_zh":"塞尺 校准 — 长度 内部程序；使用数字测量显微镜的直接法；在固定地点 (S) 长度 内部程序 使用数字测量显微镜的直接法 在固定地点 (S) – 楔形 – 扁楔 内部程序 IW/KUM/07/01","technique_zh":"内部程序；使用数字测量显微镜的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用数字测量显微镜的直接法","在固定地点 (S)"],"test_object_zh":"塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– klínové – plochý klín","range":"0,5 mm to 45 mm","cmc":"8 µm"}],"reference_cs":"Vnitřní postup IW/KUM/07/01","regulatory_area_cs":"Délka","search_cs":"Spároměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím digitálního měřicího mikroskopu; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím digitálního měřicího mikroskopu Ve stálé lokalitě (S) – klínové – plochý klín Vnitřní postup IW/KUM/07/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím digitálního měřicího mikroskopu; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím digitálního měřicího mikroskopu","Ve stálé lokalitě (S)"],"test_object_cs":"Spároměry"},{"_id":"a1df98ec45f013b347e39a89","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Średnicówki czujnikowe dwupunktowe\n– działka elementarna 0,01 mm\n– rozdzielczość 0,001 mm","test_object_en":"Two-point dial bore gauges\n– scale interval 0,01 mm\n– resolution 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"3,5 mm do 35 mm","cmc":"2,1 µm"},{"name":"","range":"35 mm do 60 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm do 150 mm","cmc":"2,2 µm"},{"name":"","range":"150 mm do 250 mm","cmc":"3,4 µm"},{"name":"","range":"250 mm do 400 mm","cmc":"5,1 µm"},{"name":"","range":"400 mm do 600 mm","cmc":"7,8 µm"},{"name":"","range":"600 mm do 800 mm","cmc":"11,5 µm"}],"parameters_en":[{"name":"","range":"3,5 mm to 35 mm","cmc":"2,1 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"2,2 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"3,4 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"5,1 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"7,8 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"11,5 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n3,5 mm do 35 mm CMC 2,1 µm\n35 mm do 60 mm CMC 2,1 µm\n50 mm do 150 mm CMC 2,2 µm\n150 mm do 250 mm CMC 3,4 µm\n250 mm do 400 mm CMC 5,1 µm\n400 mm do 600 mm CMC 7,8 µm\n600 mm do 800 mm CMC 11,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/14/01","norm_bases":["IW/KUM/14/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki czujnikowe dwupunktowe\n– działka elementarna 0,01 mm\n– rozdzielczość 0,001 mm Wzorcowanie — Długość\nZakres:\n3,5 mm do 35 mm CMC 2,1 µm\n35 mm do 60 mm CMC 2,1 µm\n50 mm do 150 mm CMC 2,2 µm\n150 mm do 250 mm CMC 3,4 µm\n250 mm do 400 mm CMC 5,1 µm\n400 mm do 600 mm CMC 7,8 µm\n600 mm do 800 mm CMC 11,5 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/14/01 Srednicowki czujnikowe dwupunktowe\n– dzialka elementarna 0,01 mm\n– rozdzielczosc 0,001 mm Wzorcowanie — Dlugosc\nZakres:\n3,5 mm do 35 mm CMC 2,1 µm\n35 mm do 60 mm CMC 2,1 µm\n50 mm do 150 mm CMC 2,2 µm\n150 mm do 250 mm CMC 3,4 µm\n250 mm do 400 mm CMC 5,1 µm\n400 mm do 600 mm CMC 7,8 µm\n600 mm do 800 mm CMC 11,5 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/14/01","search_en":"Two-point dial bore gauges – scale interval 0,01 mm – resolution 0,001 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/14/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":71,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/14/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"3,5 mm to 35 mm","cmc":"2,1 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"2,2 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"3,4 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"5,1 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"7,8 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"11,5 µm"}],"reference_de":"Internes Verfahren IW/KUM/14/01","regulatory_area_de":"Länge","search_de":"Zweipunkt-Innenfeinmessgeräte – Skalenteilungswert 0,01 mm – Auflösung 0,001 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/14/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Zweipunkt-Innenfeinmessgeräte\n– Skalenteilungswert 0,01 mm\n– Auflösung 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"3,5 mm to 35 mm","cmc":"2,1 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"2,2 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"3,4 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"5,1 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"7,8 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"11,5 µm"}],"reference_zh":"内部程序 IW/KUM/14/01","regulatory_area_zh":"长度","search_zh":"两点式内径指示表 – 分度值 0,01 mm – 分辨力 0,001 mm 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/14/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"两点式内径指示表\n– 分度值 0,01 mm\n– 分辨力 0,001 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"3,5 mm to 35 mm","cmc":"2,1 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"2,1 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"2,2 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"3,4 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"5,1 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"7,8 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"11,5 µm"}],"reference_cs":"Vnitřní postup IW/KUM/14/01","regulatory_area_cs":"Délka","search_cs":"Dvoudotekové dutinoměry s úchylkoměrem – hodnota dílku 0,01 mm – rozlišení 0,001 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/14/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Dvoudotekové dutinoměry s úchylkoměrem\n– hodnota dílku 0,01 mm\n– rozlišení 0,001 mm"},{"_id":"4cadedea4cbdbba8d3fade91","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Średnicówki czujnikowe dwupunktowe\n– działka elementarna 0,001 mm\n– działka elementarna 0,0005 mm","test_object_en":"Two-point dial bore gauges\n– scale interval 0,001 mm\n– scale interval 0,0005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"3,5 mm do 35 mm","cmc":"0,8 µm"},{"name":"","range":"35 mm do 60 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm do 150 mm","cmc":"1,1 µm"},{"name":"","range":"150 mm do 250 mm","cmc":"2,9 µm"},{"name":"","range":"250 mm do 400 mm","cmc":"4,7 µm"},{"name":"","range":"400 mm do 600 mm","cmc":"7,5 µm"},{"name":"","range":"600 mm do 800 mm","cmc":"11,3 µm"}],"parameters_en":[{"name":"","range":"3,5 mm to 35 mm","cmc":"0,8 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"1,1 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"2,9 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"4,7 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"7,5 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"11,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n3,5 mm do 35 mm CMC 0,8 µm\n35 mm do 60 mm CMC 0,9 µm\n50 mm do 150 mm CMC 1,1 µm\n150 mm do 250 mm CMC 2,9 µm\n250 mm do 400 mm CMC 4,7 µm\n400 mm do 600 mm CMC 7,5 µm\n600 mm do 800 mm CMC 11,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/14/01","norm_bases":["IW/KUM/14/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki czujnikowe dwupunktowe\n– działka elementarna 0,001 mm\n– działka elementarna 0,0005 mm Wzorcowanie — Długość\nZakres:\n3,5 mm do 35 mm CMC 0,8 µm\n35 mm do 60 mm CMC 0,9 µm\n50 mm do 150 mm CMC 1,1 µm\n150 mm do 250 mm CMC 2,9 µm\n250 mm do 400 mm CMC 4,7 µm\n400 mm do 600 mm CMC 7,5 µm\n600 mm do 800 mm CMC 11,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/14/01 Srednicowki czujnikowe dwupunktowe\n– dzialka elementarna 0,001 mm\n– dzialka elementarna 0,0005 mm Wzorcowanie — Dlugosc\nZakres:\n3,5 mm do 35 mm CMC 0,8 µm\n35 mm do 60 mm CMC 0,9 µm\n50 mm do 150 mm CMC 1,1 µm\n150 mm do 250 mm CMC 2,9 µm\n250 mm do 400 mm CMC 4,7 µm\n400 mm do 600 mm CMC 7,5 µm\n600 mm do 800 mm CMC 11,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/14/01","search_en":"Two-point dial bore gauges – scale interval 0,001 mm – scale interval 0,0005 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/14/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":72,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/14/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"3,5 mm to 35 mm","cmc":"0,8 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"1,1 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"2,9 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"4,7 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"7,5 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"11,3 µm"}],"reference_de":"Internes Verfahren IW/KUM/14/01","regulatory_area_de":"Länge","search_de":"Zweipunkt-Innenfeinmessgeräte – Skalenteilungswert 0,001 mm – Skalenteilungswert 0,0005 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/14/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Zweipunkt-Innenfeinmessgeräte\n– Skalenteilungswert 0,001 mm\n– Skalenteilungswert 0,0005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"3,5 mm to 35 mm","cmc":"0,8 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"1,1 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"2,9 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"4,7 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"7,5 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"11,3 µm"}],"reference_zh":"内部程序 IW/KUM/14/01","regulatory_area_zh":"长度","search_zh":"两点式内径指示表 – 分度值 0,001 mm – 分度值 0,0005 mm 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/14/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"两点式内径指示表\n– 分度值 0,001 mm\n– 分度值 0,0005 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"3,5 mm to 35 mm","cmc":"0,8 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"1,1 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"2,9 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"4,7 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"7,5 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"11,3 µm"}],"reference_cs":"Vnitřní postup IW/KUM/14/01","regulatory_area_cs":"Délka","search_cs":"Dvoudotekové dutinoměry s úchylkoměrem – hodnota dílku 0,001 mm – hodnota dílku 0,0005 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/14/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Dvoudotekové dutinoměry s úchylkoměrem\n– hodnota dílku 0,001 mm\n– hodnota dílku 0,0005 mm"},{"_id":"b36b3b61b485b9f06c160690","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Średnicówki czujnikowe dwupunktowe\n– rozdzielczość 0,01 mm","test_object_en":"Two-point dial bore gauges\n– resolution 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"3,5 mm do 35 mm","cmc":"8,7 µm"},{"name":"","range":"35 mm do 60 mm","cmc":"8,7 µm"},{"name":"","range":"50 mm do 150 mm","cmc":"8,7 µm"},{"name":"","range":"150 mm do 250 mm","cmc":"9,0 µm"},{"name":"","range":"250 mm do 400 mm","cmc":"9,8 µm"},{"name":"","range":"400 mm do 600 mm","cmc":"11,4 µm"},{"name":"","range":"600 mm do 800 mm","cmc":"14,3 µm"}],"parameters_en":[{"name":"","range":"3,5 mm to 35 mm","cmc":"8,7 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"8,7 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"8,7 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"9,0 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"9,8 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"11,4 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"14,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n3,5 mm do 35 mm CMC 8,7 µm\n35 mm do 60 mm CMC 8,7 µm\n50 mm do 150 mm CMC 8,7 µm\n150 mm do 250 mm CMC 9,0 µm\n250 mm do 400 mm CMC 9,8 µm\n400 mm do 600 mm CMC 11,4 µm\n600 mm do 800 mm CMC 14,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/14/01","norm_bases":["IW/KUM/14/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki czujnikowe dwupunktowe\n– rozdzielczość 0,01 mm Wzorcowanie — Długość\nZakres:\n3,5 mm do 35 mm CMC 8,7 µm\n35 mm do 60 mm CMC 8,7 µm\n50 mm do 150 mm CMC 8,7 µm\n150 mm do 250 mm CMC 9,0 µm\n250 mm do 400 mm CMC 9,8 µm\n400 mm do 600 mm CMC 11,4 µm\n600 mm do 800 mm CMC 14,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/14/01 Srednicowki czujnikowe dwupunktowe\n– rozdzielczosc 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n3,5 mm do 35 mm CMC 8,7 µm\n35 mm do 60 mm CMC 8,7 µm\n50 mm do 150 mm CMC 8,7 µm\n150 mm do 250 mm CMC 9,0 µm\n250 mm do 400 mm CMC 9,8 µm\n400 mm do 600 mm CMC 11,4 µm\n600 mm do 800 mm CMC 14,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/14/01","search_en":"Two-point dial bore gauges – resolution 0,01 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/14/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":73,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/14/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"3,5 mm to 35 mm","cmc":"8,7 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"8,7 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"8,7 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"9,0 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"9,8 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"11,4 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"14,3 µm"}],"reference_de":"Internes Verfahren IW/KUM/14/01","regulatory_area_de":"Länge","search_de":"Zweipunkt-Innenfeinmessgeräte – Auflösung 0,01 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/14/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Zweipunkt-Innenfeinmessgeräte\n– Auflösung 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"3,5 mm to 35 mm","cmc":"8,7 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"8,7 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"8,7 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"9,0 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"9,8 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"11,4 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"14,3 µm"}],"reference_zh":"内部程序 IW/KUM/14/01","regulatory_area_zh":"长度","search_zh":"两点式内径指示表 – 分辨力 0,01 mm 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/14/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"两点式内径指示表\n– 分辨力 0,01 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"3,5 mm to 35 mm","cmc":"8,7 µm"},{"name":"","range":"35 mm to 60 mm","cmc":"8,7 µm"},{"name":"","range":"50 mm to 150 mm","cmc":"8,7 µm"},{"name":"","range":"150 mm to 250 mm","cmc":"9,0 µm"},{"name":"","range":"250 mm to 400 mm","cmc":"9,8 µm"},{"name":"","range":"400 mm to 600 mm","cmc":"11,4 µm"},{"name":"","range":"600 mm to 800 mm","cmc":"14,3 µm"}],"reference_cs":"Vnitřní postup IW/KUM/14/01","regulatory_area_cs":"Délka","search_cs":"Dvoudotekové dutinoměry s úchylkoměrem – rozlišení 0,01 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/14/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Dvoudotekové dutinoměry s úchylkoměrem\n– rozlišení 0,01 mm"},{"_id":"15fff5256d1e256cc42c3fff","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Średnicówki czujnikowe dwupunktowe\n– rozdzielczość 0,0005 mm","test_object_en":"Two-point dial bore gauges\n– resolution 0,0005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"3,5 mm do 18 mm","cmc":"1,2 µm"}],"parameters_en":[{"name":"","range":"3,5 mm to 18 mm","cmc":"1,2 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n3,5 mm do 18 mm CMC 1,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/14/01","norm_bases":["IW/KUM/14/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki czujnikowe dwupunktowe\n– rozdzielczość 0,0005 mm Wzorcowanie — Długość\n3,5 mm do 18 mm CMC 1,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/14/01 Srednicowki czujnikowe dwupunktowe\n– rozdzielczosc 0,0005 mm Wzorcowanie — Dlugosc\n3,5 mm do 18 mm CMC 1,2 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/14/01","search_en":"Two-point dial bore gauges – resolution 0,0005 mm Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/14/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":74,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/14/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"3,5 mm to 18 mm","cmc":"1,2 µm"}],"reference_de":"Internes Verfahren IW/KUM/14/01","regulatory_area_de":"Länge","search_de":"Zweipunkt-Innenfeinmessgeräte – Auflösung 0,0005 mm Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/14/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Zweipunkt-Innenfeinmessgeräte\n– Auflösung 0,0005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"3,5 mm to 18 mm","cmc":"1,2 µm"}],"reference_zh":"内部程序 IW/KUM/14/01","regulatory_area_zh":"长度","search_zh":"两点式内径指示表 – 分辨力 0,0005 mm 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/14/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"两点式内径指示表\n– 分辨力 0,0005 mm","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"3,5 mm to 18 mm","cmc":"1,2 µm"}],"reference_cs":"Vnitřní postup IW/KUM/14/01","regulatory_area_cs":"Délka","search_cs":"Dvoudotekové dutinoměry s úchylkoměrem – rozlišení 0,0005 mm Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/14/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Dvoudotekové dutinoměry s úchylkoměrem\n– rozlišení 0,0005 mm"},{"_id":"c6ab9a844af68d9bad46fbc4","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Średnicówki mikrometryczne dwupunktowe","test_object_en":"Two-point micrometer bore gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"30 mm","cmc":"0,8 µm"},{"name":"","range":"35 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm","cmc":"1,0 µm"},{"name":"","range":"63 mm","cmc":"1,2 µm"},{"name":"","range":"75 mm","cmc":"1,3 µm"},{"name":"","range":"88 mm","cmc":"1,5 µm"},{"name":"","range":"100 mm","cmc":"1,6 µm"},{"name":"","range":"125 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm","cmc":"2,3 µm"},{"name":"","range":"175 mm","cmc":"2,6 µm"},{"name":"","range":"200 mm","cmc":"2,9 µm"},{"name":"","range":"225 mm","cmc":"3,3 µm"},{"name":"","range":"250 mm","cmc":"3,6 µm"},{"name":"","range":"275 mm","cmc":"3,9 µm"},{"name":"","range":"300 mm","cmc":"4,3 µm"},{"name":"","range":"325 mm","cmc":"4,6 µm"},{"name":"","range":"350 mm","cmc":"4,9 µm"},{"name":"","range":"375 mm","cmc":"5,3 µm"}],"parameters_en":[{"name":"","range":"30 mm","cmc":"0,8 µm"},{"name":"","range":"35 mm","cmc":"0,9 µm"},{"name":"","range":"50 mm","cmc":"1,0 µm"},{"name":"","range":"63 mm","cmc":"1,2 µm"},{"name":"","range":"75 mm","cmc":"1,3 µm"},{"name":"","range":"88 mm","cmc":"1,5 µm"},{"name":"","range":"100 mm","cmc":"1,6 µm"},{"name":"","range":"125 mm","cmc":"1,9 µm"},{"name":"","range":"150 mm","cmc":"2,3 µm"},{"name":"","range":"175 mm","cmc":"2,6 µm"},{"name":"","range":"200 mm","cmc":"2,9 µm"},{"name":"","range":"225 mm","cmc":"3,3 µm"},{"name":"","range":"250 mm","cmc":"3,6 µm"},{"name":"","range":"275 mm","cmc":"3,9 µm"},{"name":"","range":"300 mm","cmc":"4,3 µm"},{"name":"","range":"325 mm","cmc":"4,6 µm"},{"name":"","range":"350 mm","cmc":"4,9 µm"},{"name":"","range":"375 mm","cmc":"5,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n30 mm CMC 0,8 µm\n35 mm CMC 0,9 µm\n50 mm CMC 1,0 µm\n63 mm CMC 1,2 µm\n75 mm CMC 1,3 µm\n88 mm CMC 1,5 µm\n100 mm CMC 1,6 µm\n125 mm CMC 1,9 µm\n150 mm CMC 2,3 µm\n175 mm CMC 2,6 µm\n200 mm CMC 2,9 µm\n225 mm CMC 3,3 µm\n250 mm CMC 3,6 µm\n275 mm CMC 3,9 µm\n300 mm CMC 4,3 µm\n325 mm CMC 4,6 µm\n350 mm CMC 4,9 µm\n375 mm CMC 5,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/02/04","norm_bases":["IW/KUM/02/04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki mikrometryczne dwupunktowe Wzorcowanie — Długość\nZakres:\n30 mm CMC 0,8 µm\n35 mm CMC 0,9 µm\n50 mm CMC 1,0 µm\n63 mm CMC 1,2 µm\n75 mm CMC 1,3 µm\n88 mm CMC 1,5 µm\n100 mm CMC 1,6 µm\n125 mm CMC 1,9 µm\n150 mm CMC 2,3 µm\n175 mm CMC 2,6 µm\n200 mm CMC 2,9 µm\n225 mm CMC 3,3 µm\n250 mm CMC 3,6 µm\n275 mm CMC 3,9 µm\n300 mm CMC 4,3 µm\n325 mm CMC 4,6 µm\n350 mm CMC 4,9 µm\n375 mm CMC 5,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/02/04 Srednicowki mikrometryczne dwupunktowe Wzorcowanie — Dlugosc\nZakres:\n30 mm CMC 0,8 µm\n35 mm CMC 0,9 µm\n50 mm CMC 1,0 µm\n63 mm CMC 1,2 µm\n75 mm CMC 1,3 µm\n88 mm CMC 1,5 µm\n100 mm CMC 1,6 µm\n125 mm CMC 1,9 µm\n150 mm CMC 2,3 µm\n175 mm CMC 2,6 µm\n200 mm CMC 2,9 µm\n225 mm CMC 3,3 µm\n250 mm CMC 3,6 µm\n275 mm CMC 3,9 µm\n300 mm CMC 4,3 µm\n325 mm CMC 4,6 µm\n350 mm CMC 4,9 µm\n375 mm CMC 5,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/02/04","search_en":"Two-point micrometer bore gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/02/04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":75,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/02/04","methodology_de":"Kalibrierung — Länge","reference_de":"Internes Verfahren IW/KUM/02/04","regulatory_area_de":"Länge","search_de":"Zweipunkt-Innenmessschrauben Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/02/04","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Zweipunkt-Innenmessschrauben","methodology_zh":"校准 — 长度","reference_zh":"内部程序 IW/KUM/02/04","regulatory_area_zh":"长度","search_zh":"两点式内径千分尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/02/04","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"两点式内径千分尺","methodology_cs":"Kalibrace — Délka","reference_cs":"Vnitřní postup IW/KUM/02/04","regulatory_area_cs":"Délka","search_cs":"Dvoudotekové mikrometrické odpichy Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/02/04","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Dvoudotekové mikrometrické odpichy"},{"_id":"bc64771cf442fbd97557907f","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Średnicówki mikrometryczne trójpunktowe\nŚrednicówki czujnikowe trójpunktowe","test_object_en":"Three-point micrometer bore gauges\nThree-point dial bore gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"3 mm do 100 mm","cmc":"1,9 µm"},{"name":"","range":"100 mm do 175 mm","cmc":"2,9 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"4,3 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"4,8 µm"}],"parameters_en":[{"name":"","range":"3 mm do 100 mm","cmc":"1,9 µm"},{"name":"","range":"100 mm do 175 mm","cmc":"2,9 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"4,3 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"4,8 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem pierścieni wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using setting rings; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem pierścieni wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using setting rings","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n3 mm do 100 mm CMC 1,9 µm\n100 mm do 175 mm CMC 2,9 µm\n175 mm do 200 mm CMC 3,0 µm\n200 mm do 250 mm CMC 4,3 µm\n250 mm do 300 mm CMC 4,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem pierścieni wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/02/05","norm_bases":["IW/KUM/02/05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki mikrometryczne trójpunktowe\nŚrednicówki czujnikowe trójpunktowe Wzorcowanie — Długość\nZakres:\n3 mm do 100 mm CMC 1,9 µm\n100 mm do 175 mm CMC 2,9 µm\n175 mm do 200 mm CMC 3,0 µm\n200 mm do 250 mm CMC 4,3 µm\n250 mm do 300 mm CMC 4,8 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem pierścieni wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/02/05 Srednicowki mikrometryczne trojpunktowe\nSrednicowki czujnikowe trojpunktowe Wzorcowanie — Dlugosc\nZakres:\n3 mm do 100 mm CMC 1,9 µm\n100 mm do 175 mm CMC 2,9 µm\n175 mm do 200 mm CMC 3,0 µm\n200 mm do 250 mm CMC 4,3 µm\n250 mm do 300 mm CMC 4,8 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem pierscieni wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/02/05","search_en":"Three-point micrometer bore gauges Three-point dial bore gauges Calibration — Length Internal procedure; Direct method using setting rings; At permanent location (S) Length Internal procedure Direct method using setting rings At permanent location (S) Internal procedure IW/KUM/02/05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":76,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/02/05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"3 mm do 100 mm","cmc":"1,9 µm"},{"name":"","range":"100 mm do 175 mm","cmc":"2,9 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"4,3 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"4,8 µm"}],"reference_de":"Internes Verfahren IW/KUM/02/05","regulatory_area_de":"Länge","search_de":"Dreipunkt-Innenmessschrauben Dreipunkt-Innenfeinmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Einstellringen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Einstellringen Am festen Standort (S) Internes Verfahren IW/KUM/02/05","technique_de":"Internes Verfahren; Direktes Verfahren mit Einstellringen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Einstellringen","Am festen Standort (S)"],"test_object_de":"Dreipunkt-Innenmessschrauben\nDreipunkt-Innenfeinmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"3 mm do 100 mm","cmc":"1,9 µm"},{"name":"","range":"100 mm do 175 mm","cmc":"2,9 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"4,3 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"4,8 µm"}],"reference_zh":"内部程序 IW/KUM/02/05","regulatory_area_zh":"长度","search_zh":"三点式内径千分尺 三点式指示表内径规 校准 — 长度 内部程序；使用校对环规的直接法；在固定地点 (S) 长度 内部程序 使用校对环规的直接法 在固定地点 (S) 内部程序 IW/KUM/02/05","technique_zh":"内部程序；使用校对环规的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用校对环规的直接法","在固定地点 (S)"],"test_object_zh":"三点式内径千分尺\n三点式指示表内径规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"3 mm do 100 mm","cmc":"1,9 µm"},{"name":"","range":"100 mm do 175 mm","cmc":"2,9 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"4,3 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"4,8 µm"}],"reference_cs":"Vnitřní postup IW/KUM/02/05","regulatory_area_cs":"Délka","search_cs":"Třídotekové mikrometrické dutinoměry Třídotekové dutinoměry s úchylkoměrem Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím nastavovacích kroužků; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím nastavovacích kroužků Ve stálé lokalitě (S) Vnitřní postup IW/KUM/02/05","technique_cs":"Vnitřní postup; Přímá metoda s použitím nastavovacích kroužků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím nastavovacích kroužků","Ve stálé lokalitě (S)"],"test_object_cs":"Třídotekové mikrometrické dutinoměry\nTřídotekové dutinoměry s úchylkoměrem"},{"_id":"69d4f428fdbe4cd45e95e64f","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Transametry","test_object_en":"Transameters","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– zakres czujnika transametru","range":"-140 µm do 140 µm","cmc":"0,3 µm"},{"name":"– zakres transametru","range":"0 mm do 150 mm","cmc":"0,3 µm"}],"parameters_en":[{"name":"– transameter indicator range","range":"-140 µm to 140 µm","cmc":"0,3 µm"},{"name":"– transameter range","range":"0 mm to 150 mm","cmc":"0,3 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– zakres czujnika transametru -140 µm do 140 µm CMC 0,3 µm\n– zakres transametru 0 mm do 150 mm CMC 0,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/02/03","norm_bases":["IW/KUM/02/03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Transametry Wzorcowanie — Długość\nZakres:\n– zakres czujnika transametru -140 µm do 140 µm CMC 0,3 µm\n– zakres transametru 0 mm do 150 mm CMC 0,3 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/02/03 Transametry Wzorcowanie — Dlugosc\nZakres:\n– zakres czujnika transametru -140 µm do 140 µm CMC 0,3 µm\n– zakres transametru 0 mm do 150 mm CMC 0,3 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/02/03","search_en":"Transameters Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) – transameter indicator range – transameter range Internal procedure IW/KUM/02/03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":77,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/02/03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Messbereich der Transameter-Messuhr","range":"-140 µm to 140 µm","cmc":"0,3 µm"},{"name":"– Messbereich des Transameters","range":"0 mm to 150 mm","cmc":"0,3 µm"}],"reference_de":"Internes Verfahren IW/KUM/02/03","regulatory_area_de":"Länge","search_de":"Transameter Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) – Messbereich der Transameter-Messuhr – Messbereich des Transameters Internes Verfahren IW/KUM/02/03","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Transameter","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 杠杆千分尺指示表量程","range":"-140 µm to 140 µm","cmc":"0,3 µm"},{"name":"– 杠杆千分尺量程","range":"0 mm to 150 mm","cmc":"0,3 µm"}],"reference_zh":"内部程序 IW/KUM/02/03","regulatory_area_zh":"长度","search_zh":"Transametr 量仪 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) – 杠杆千分尺指示表量程 – 杠杆千分尺量程 内部程序 IW/KUM/02/03","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"Transametr 量仪","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– rozsah úchylkoměru transametru","range":"-140 µm to 140 µm","cmc":"0,3 µm"},{"name":"– rozsah transametru","range":"0 mm to 150 mm","cmc":"0,3 µm"}],"reference_cs":"Vnitřní postup IW/KUM/02/03","regulatory_area_cs":"Délka","search_cs":"Pasametry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) – rozsah úchylkoměru transametru – rozsah transametru Vnitřní postup IW/KUM/02/03","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Pasametry"},{"_id":"abb1889a2a4c00b6bd82c4c4","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wałeczki pomiarowe","test_object_en":"Measuring rollers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– do gwintów","range":"0,17 mm do 6,35 mm","cmc":"0,40 µm"},{"name":"– do otworów","range":"0,05 mm do 10,0 mm","cmc":"0,36 µm"},{"name":"– do otworów","range":"10,0 mm do 20,0 mm","cmc":"0,37 µm"},{"name":"– do kół zębatych","range":"1,7 mm do 17 mm","cmc":"0,37 µm"}],"parameters_en":[{"name":"– for threads","range":"0,17 mm to 6,35 mm","cmc":"0,40 µm"},{"name":"– for holes","range":"0,05 mm to 10,0 mm","cmc":"0,36 µm"},{"name":"– for holes","range":"10,0 mm to 20,0 mm","cmc":"0,37 µm"},{"name":"– for gears","range":"1,7 mm to 17 mm","cmc":"0,37 µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika CARL ZEISS JENA MOP 02/20; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparative method using gauge blocks and a CARL ZEISS JENA MOP 02/20 probe; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika CARL ZEISS JENA MOP 02/20","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparative method using gauge blocks and a CARL ZEISS JENA MOP 02/20 probe","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– do gwintów 0,17 mm do 6,35 mm CMC 0,40 µm\n– do otworów 0,05 mm do 10,0 mm CMC 0,36 µm\n– do otworów 10,0 mm do 20,0 mm CMC 0,37 µm\n– do kół zębatych 1,7 mm do 17 mm CMC 0,37 µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika CARL ZEISS JENA MOP 02/20; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/09/01","norm_bases":["IW/KUM/09/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wałeczki pomiarowe Wzorcowanie — Długość\nZakres:\n– do gwintów 0,17 mm do 6,35 mm CMC 0,40 µm\n– do otworów 0,05 mm do 10,0 mm CMC 0,36 µm\n– do otworów 10,0 mm do 20,0 mm CMC 0,37 µm\n– do kół zębatych 1,7 mm do 17 mm CMC 0,37 µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem płytek wzorcowych oraz czujnika CARL ZEISS JENA MOP 02/20; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/09/01 Waleczki pomiarowe Wzorcowanie — Dlugosc\nZakres:\n– do gwintow 0,17 mm do 6,35 mm CMC 0,40 µm\n– do otworow 0,05 mm do 10,0 mm CMC 0,36 µm\n– do otworow 10,0 mm do 20,0 mm CMC 0,37 µm\n– do kol zebatych 1,7 mm do 17 mm CMC 0,37 µm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem plytek wzorcowych oraz czujnika CARL ZEISS JENA MOP 02/20; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/09/01","search_en":"Measuring rollers Calibration — Length Internal procedure; Comparative method using gauge blocks and a CARL ZEISS JENA MOP 02/20 probe; At permanent location (S) Length Internal procedure Comparative method using gauge blocks and a CARL ZEISS JENA MOP 02/20 probe At permanent location (S) – for threads – for holes – for holes – for gears Internal procedure IW/KUM/09/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":78,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/09/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– für Gewinde","range":"0,17 mm to 6,35 mm","cmc":"0,40 µm"},{"name":"– für Bohrungen","range":"0,05 mm to 10,0 mm","cmc":"0,36 µm"},{"name":"– für Bohrungen","range":"10,0 mm to 20,0 mm","cmc":"0,37 µm"},{"name":"– für Zahnräder","range":"1,7 mm to 17 mm","cmc":"0,37 µm"}],"reference_de":"Internes Verfahren IW/KUM/09/01","regulatory_area_de":"Länge","search_de":"Messrollen Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit Parallelendmaßen und einem Messtaster CARL ZEISS JENA MOP 02/20; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit Parallelendmaßen und einem Messtaster CARL ZEISS JENA MOP 02/20 Am festen Standort (S) – für Gewinde – für Bohrungen – für Bohrungen – für Zahnräder Internes Verfahren IW/KUM/09/01","technique_de":"Internes Verfahren; Vergleichsverfahren mit Parallelendmaßen und einem Messtaster CARL ZEISS JENA MOP 02/20; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit Parallelendmaßen und einem Messtaster CARL ZEISS JENA MOP 02/20","Am festen Standort (S)"],"test_object_de":"Messrollen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 用于螺纹","range":"0,17 mm to 6,35 mm","cmc":"0,40 µm"},{"name":"– 用于孔","range":"0,05 mm to 10,0 mm","cmc":"0,36 µm"},{"name":"– 用于孔","range":"10,0 mm to 20,0 mm","cmc":"0,37 µm"},{"name":"– 用于齿轮","range":"1,7 mm to 17 mm","cmc":"0,37 µm"}],"reference_zh":"内部程序 IW/KUM/09/01","regulatory_area_zh":"长度","search_zh":"测量用量棒 校准 — 长度 内部程序；使用量块和CARL ZEISS JENA MOP 02/20测头的比较法；在固定地点 (S) 长度 内部程序 使用量块和CARL ZEISS JENA MOP 02/20测头的比较法 在固定地点 (S) – 用于螺纹 – 用于孔 – 用于孔 – 用于齿轮 内部程序 IW/KUM/09/01","technique_zh":"内部程序；使用量块和CARL ZEISS JENA MOP 02/20测头的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用量块和CARL ZEISS JENA MOP 02/20测头的比较法","在固定地点 (S)"],"test_object_zh":"测量用量棒","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– pro závity","range":"0,17 mm to 6,35 mm","cmc":"0,40 µm"},{"name":"– pro otvory","range":"0,05 mm to 10,0 mm","cmc":"0,36 µm"},{"name":"– pro otvory","range":"10,0 mm to 20,0 mm","cmc":"0,37 µm"},{"name":"– pro ozubená kola","range":"1,7 mm to 17 mm","cmc":"0,37 µm"}],"reference_cs":"Vnitřní postup IW/KUM/09/01","regulatory_area_cs":"Délka","search_cs":"Měřicí válečky Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím koncových měrek a snímače CARL ZEISS JENA MOP 02/20; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím koncových měrek a snímače CARL ZEISS JENA MOP 02/20 Ve stálé lokalitě (S) – pro závity – pro otvory – pro otvory – pro ozubená kola Vnitřní postup IW/KUM/09/01","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím koncových měrek a snímače CARL ZEISS JENA MOP 02/20; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím koncových měrek a snímače CARL ZEISS JENA MOP 02/20","Ve stálé lokalitě (S)"],"test_object_cs":"Měřicí válečky"},{"_id":"83317e8f53f90928a41adfd3","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wałeczki pomiarowe","test_object_en":"Measuring rollers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,05 mm do 25 mm","cmc":"0,27 µm"}],"parameters_en":[{"name":"","range":"0,05 mm to 25 mm","cmc":"0,27 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an Abbe P01 vertical length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,05 mm do 25 mm CMC 0,27 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/09/02","norm_bases":["IW/KUM/09/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wałeczki pomiarowe Wzorcowanie — Długość\n0,05 mm do 25 mm CMC 0,27 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza pionowego Abbego P01; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/09/02 Waleczki pomiarowe Wzorcowanie — Dlugosc\n0,05 mm do 25 mm CMC 0,27 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza pionowego Abbego P01; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/09/02","search_en":"Measuring rollers Calibration — Length Internal procedure; Direct method using an Abbe P01 vertical length measuring machine; At permanent location (S) Length Internal procedure Direct method using an Abbe P01 vertical length measuring machine At permanent location (S) Internal procedure IW/KUM/09/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":79,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/09/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,05 mm to 25 mm","cmc":"0,27 µm"}],"reference_de":"Internes Verfahren IW/KUM/09/02","regulatory_area_de":"Länge","search_de":"Messrollen Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01 Am festen Standort (S) Internes Verfahren IW/KUM/09/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Abbe-Vertikallängenmessgerät P01","Am festen Standort (S)"],"test_object_de":"Messrollen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,05 mm to 25 mm","cmc":"0,27 µm"}],"reference_zh":"内部程序 IW/KUM/09/02","regulatory_area_zh":"长度","search_zh":"测量用量棒 校准 — 长度 内部程序；使用阿贝立式测长仪P01的直接法；在固定地点 (S) 长度 内部程序 使用阿贝立式测长仪P01的直接法 在固定地点 (S) 内部程序 IW/KUM/09/02","technique_zh":"内部程序；使用阿贝立式测长仪P01的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用阿贝立式测长仪P01的直接法","在固定地点 (S)"],"test_object_zh":"测量用量棒","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,05 mm to 25 mm","cmc":"0,27 µm"}],"reference_cs":"Vnitřní postup IW/KUM/09/02","regulatory_area_cs":"Délka","search_cs":"Měřicí válečky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím Abbeho svislého délkoměru P01; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím Abbeho svislého délkoměru P01 Ve stálé lokalitě (S) Vnitřní postup IW/KUM/09/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím Abbeho svislého délkoměru P01; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím Abbeho svislého délkoměru P01","Ve stálé lokalitě (S)"],"test_object_cs":"Měřicí válečky"},{"_id":"eabade620627ba6695a6efdb","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wałeczki pomiarowe","test_object_en":"Measuring rollers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,05 mm do 25 mm","cmc":"0,24 µm"}],"parameters_en":[{"name":"","range":"0,05 mm to 25 mm","cmc":"0,24 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego ULM 520 S-E; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a ULM 520 S-E horizontal length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza poziomego ULM 520 S-E","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a ULM 520 S-E horizontal length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,05 mm do 25 mm CMC 0,24 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego ULM 520 S-E; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/09/02","norm_bases":["IW/KUM/09/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wałeczki pomiarowe Wzorcowanie — Długość\n0,05 mm do 25 mm CMC 0,24 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza poziomego ULM 520 S-E; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/09/02 Waleczki pomiarowe Wzorcowanie — Dlugosc\n0,05 mm do 25 mm CMC 0,24 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza poziomego ULM 520 S-E; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/09/02","search_en":"Measuring rollers Calibration — Length Internal procedure; Direct method using a ULM 520 S-E horizontal length measuring machine; At permanent location (S) Length Internal procedure Direct method using a ULM 520 S-E horizontal length measuring machine At permanent location (S) Internal procedure IW/KUM/09/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":80,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/09/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,05 mm to 25 mm","cmc":"0,24 µm"}],"reference_de":"Internes Verfahren IW/KUM/09/02","regulatory_area_de":"Länge","search_de":"Messrollen Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Horizontal-Längenmessgerät ULM 520 S-E; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Horizontal-Längenmessgerät ULM 520 S-E Am festen Standort (S) Internes Verfahren IW/KUM/09/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Horizontal-Längenmessgerät ULM 520 S-E; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Horizontal-Längenmessgerät ULM 520 S-E","Am festen Standort (S)"],"test_object_de":"Messrollen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,05 mm to 25 mm","cmc":"0,24 µm"}],"reference_zh":"内部程序 IW/KUM/09/02","regulatory_area_zh":"长度","search_zh":"测量用量棒 校准 — 长度 内部程序；使用ULM 520 S-E卧式测长仪的直接法；在固定地点 (S) 长度 内部程序 使用ULM 520 S-E卧式测长仪的直接法 在固定地点 (S) 内部程序 IW/KUM/09/02","technique_zh":"内部程序；使用ULM 520 S-E卧式测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ULM 520 S-E卧式测长仪的直接法","在固定地点 (S)"],"test_object_zh":"测量用量棒","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,05 mm to 25 mm","cmc":"0,24 µm"}],"reference_cs":"Vnitřní postup IW/KUM/09/02","regulatory_area_cs":"Délka","search_cs":"Měřicí válečky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím vodorovného délkoměru ULM 520 S-E; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím vodorovného délkoměru ULM 520 S-E Ve stálé lokalitě (S) Vnitřní postup IW/KUM/09/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím vodorovného délkoměru ULM 520 S-E; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím vodorovného délkoměru ULM 520 S-E","Ve stálé lokalitě (S)"],"test_object_cs":"Měřicí válečky"},{"_id":"320e4b9b0905cb122d394519","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wałeczki pomiarowe","test_object_en":"Measuring rollers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,1 mm do 25 mm","cmc":"0,51 µm"}],"parameters_en":[{"name":"","range":"0,1 mm to 25 mm","cmc":"0,51 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometru laserowego skaningowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a laser scan micrometer; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem mikrometru laserowego skaningowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a laser scan micrometer","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,1 mm do 25 mm CMC 0,51 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometru laserowego skaningowego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/09/02","norm_bases":["IW/KUM/09/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wałeczki pomiarowe Wzorcowanie — Długość\n0,1 mm do 25 mm CMC 0,51 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometru laserowego skaningowego; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/09/02 Waleczki pomiarowe Wzorcowanie — Dlugosc\n0,1 mm do 25 mm CMC 0,51 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem mikrometru laserowego skaningowego; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/09/02","search_en":"Measuring rollers Calibration — Length Internal procedure; Direct method using a laser scan micrometer; At permanent location (S) Length Internal procedure Direct method using a laser scan micrometer At permanent location (S) Internal procedure IW/KUM/09/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":81,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/09/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,1 mm to 25 mm","cmc":"0,51 µm"}],"reference_de":"Internes Verfahren IW/KUM/09/02","regulatory_area_de":"Länge","search_de":"Messrollen Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Laser-Scan-Mikrometer; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Laser-Scan-Mikrometer Am festen Standort (S) Internes Verfahren IW/KUM/09/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Laser-Scan-Mikrometer; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Laser-Scan-Mikrometer","Am festen Standort (S)"],"test_object_de":"Messrollen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,1 mm to 25 mm","cmc":"0,51 µm"}],"reference_zh":"内部程序 IW/KUM/09/02","regulatory_area_zh":"长度","search_zh":"测量用量棒 校准 — 长度 内部程序；使用激光扫描测径仪的直接法；在固定地点 (S) 长度 内部程序 使用激光扫描测径仪的直接法 在固定地点 (S) 内部程序 IW/KUM/09/02","technique_zh":"内部程序；使用激光扫描测径仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用激光扫描测径仪的直接法","在固定地点 (S)"],"test_object_zh":"测量用量棒","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,1 mm to 25 mm","cmc":"0,51 µm"}],"reference_cs":"Vnitřní postup IW/KUM/09/02","regulatory_area_cs":"Délka","search_cs":"Měřicí válečky Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím laserového skenovacího mikrometru; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím laserového skenovacího mikrometru Ve stálé lokalitě (S) Vnitřní postup IW/KUM/09/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím laserového skenovacího mikrometru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím laserového skenovacího mikrometru","Ve stálé lokalitě (S)"],"test_object_cs":"Měřicí válečky"},{"_id":"3f7eedfcbfab3a57cf9e141e","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wzorce kreskowe","test_object_en":"Line standards","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 300 mm","cmc":"Q[4,5; 0,0066∙L] µm"}],"parameters_en":[{"name":"","range":"0 mm to 300 mm","cmc":"Q[4,5; 0,0066∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an ISD-V300A microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an ISD-V300A microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 300 mm CMC Q[4,5; 0,0066∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/23/01","norm_bases":["IW/KUM/23/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (mm)","note_en":"L - measured quantity (mm)","search_text":"Wzorce kreskowe Wzorcowanie — Długość\n0 mm do 300 mm CMC Q[4,5; 0,0066∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu ISD-V300A; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/23/01 Wzorce kreskowe Wzorcowanie — Dlugosc\n0 mm do 300 mm CMC Q[4,5; 0,0066∙L] µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem mikroskopu ISD-V300A; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/23/01","search_en":"Line standards Calibration — Length Internal procedure; Direct method using an ISD-V300A microscope; At permanent location (S) Length Internal procedure Direct method using an ISD-V300A microscope At permanent location (S) Internal procedure IW/KUM/23/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":82,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/23/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 300 mm","cmc":"Q[4,5; 0,0066∙L] µm"}],"reference_de":"Internes Verfahren IW/KUM/23/01","regulatory_area_de":"Länge","search_de":"Strichmaßstäbe Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Mikroskop ISD-V300A; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Mikroskop ISD-V300A Am festen Standort (S) Internes Verfahren IW/KUM/23/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Mikroskop ISD-V300A; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Mikroskop ISD-V300A","Am festen Standort (S)"],"test_object_de":"Strichmaßstäbe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 300 mm","cmc":"Q[4,5; 0,0066∙L] µm"}],"reference_zh":"内部程序 IW/KUM/23/01","regulatory_area_zh":"长度","search_zh":"线纹尺 校准 — 长度 内部程序；使用ISD-V300A显微镜的直接法；在固定地点 (S) 长度 内部程序 使用ISD-V300A显微镜的直接法 在固定地点 (S) 内部程序 IW/KUM/23/01","technique_zh":"内部程序；使用ISD-V300A显微镜的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ISD-V300A显微镜的直接法","在固定地点 (S)"],"test_object_zh":"线纹尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 300 mm","cmc":"Q[4,5; 0,0066∙L] µm"}],"reference_cs":"Vnitřní postup IW/KUM/23/01","regulatory_area_cs":"Délka","search_cs":"Čárková měřítka Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím mikroskopu ISD-V300A; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím mikroskopu ISD-V300A Ve stálé lokalitě (S) Vnitřní postup IW/KUM/23/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím mikroskopu ISD-V300A; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím mikroskopu ISD-V300A","Ve stálé lokalitě (S)"],"test_object_cs":"Čárková měřítka"},{"_id":"ec27323fabd10134c980079d","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wzorce kreskowe lup pomiarowych","test_object_en":"Line standards of measuring magnifiers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 30 mm","cmc":"3,2 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"4,0 µm"}],"parameters_en":[{"name":"","range":"0 mm do 30 mm","cmc":"3,2 µm"},{"name":"","range":"0 mm to 50 mm","cmc":"4,0 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using a Mitutoyo measuring microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using a Mitutoyo measuring microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 30 mm CMC 3,2 µm\n0 mm do 50 mm CMC 4,0 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/10/04","norm_bases":["IW/KUM/10/04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce kreskowe lup pomiarowych Wzorcowanie — Długość\nZakres:\n0 mm do 30 mm CMC 3,2 µm\n0 mm do 50 mm CMC 4,0 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/10/04 Wzorce kreskowe lup pomiarowych Wzorcowanie — Dlugosc\nZakres:\n0 mm do 30 mm CMC 3,2 µm\n0 mm do 50 mm CMC 4,0 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/10/04","search_en":"Line standards of measuring magnifiers Calibration — Length Internal procedure; Indirect method using a Mitutoyo measuring microscope; At permanent location (S) Length Internal procedure Indirect method using a Mitutoyo measuring microscope At permanent location (S) Internal procedure IW/KUM/10/04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":83,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/10/04","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 30 mm","cmc":"3,2 µm"},{"name":"","range":"0 mm bis 50 mm","cmc":"4,0 µm"}],"reference_de":"Internes Verfahren IW/KUM/10/04","regulatory_area_de":"Länge","search_de":"Strichmaßstäbe von Messlupen Kalibrierung — Länge Internes Verfahren; Indirektes Verfahren mit einem Messmikroskop Mitutoyo; Am festen Standort (S) Länge Internes Verfahren Indirektes Verfahren mit einem Messmikroskop Mitutoyo Am festen Standort (S) Internes Verfahren IW/KUM/10/04","technique_de":"Internes Verfahren; Indirektes Verfahren mit einem Messmikroskop Mitutoyo; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit einem Messmikroskop Mitutoyo","Am festen Standort (S)"],"test_object_de":"Strichmaßstäbe von Messlupen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 30 mm","cmc":"3,2 µm"},{"name":"","range":"0 mm 至 50 mm","cmc":"4,0 µm"}],"reference_zh":"内部程序 IW/KUM/10/04","regulatory_area_zh":"长度","search_zh":"测量放大镜线纹尺 校准 — 长度 内部程序；使用Mitutoyo测量显微镜的间接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo测量显微镜的间接法 在固定地点 (S) 内部程序 IW/KUM/10/04","technique_zh":"内部程序；使用Mitutoyo测量显微镜的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo测量显微镜的间接法","在固定地点 (S)"],"test_object_zh":"测量放大镜线纹尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 30 mm","cmc":"3,2 µm"},{"name":"","range":"0 mm do 50 mm","cmc":"4,0 µm"}],"reference_cs":"Vnitřní postup IW/KUM/10/04","regulatory_area_cs":"Délka","search_cs":"Čárková měřítka měřicích lup Kalibrace — Délka Vnitřní postup; Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo Ve stálé lokalitě (S) Vnitřní postup IW/KUM/10/04","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo","Ve stálé lokalitě (S)"],"test_object_cs":"Čárková měřítka měřicích lup"},{"_id":"38547088bcc849982cd7a498","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wzorce łuków kołowych (promieniomierze)","test_object_en":"Circular arc standards (radius gauges)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"1 mm do 7 mm","cmc":"4 µm"},{"name":"","range":"7,5 mm do 15 mm","cmc":"15 µm"},{"name":"","range":"15,5 mm do 25 mm","cmc":"21 µm"}],"parameters_en":[{"name":"","range":"1 mm to 7 mm","cmc":"4 µm"},{"name":"","range":"7,5 mm to 15 mm","cmc":"15 µm"},{"name":"","range":"15,5 mm to 25 mm","cmc":"21 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using a Mitutoyo measuring microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using a Mitutoyo measuring microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n1 mm do 7 mm CMC 4 µm\n7,5 mm do 15 mm CMC 15 µm\n15,5 mm do 25 mm CMC 21 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/10/01","norm_bases":["IW/KUM/10/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce łuków kołowych (promieniomierze) Wzorcowanie — Długość\nZakres:\n1 mm do 7 mm CMC 4 µm\n7,5 mm do 15 mm CMC 15 µm\n15,5 mm do 25 mm CMC 21 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/10/01 Wzorce lukow kolowych (promieniomierze) Wzorcowanie — Dlugosc\nZakres:\n1 mm do 7 mm CMC 4 µm\n7,5 mm do 15 mm CMC 15 µm\n15,5 mm do 25 mm CMC 21 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/10/01","search_en":"Circular arc standards (radius gauges) Calibration — Length Internal procedure; Indirect method using a Mitutoyo measuring microscope; At permanent location (S) Length Internal procedure Indirect method using a Mitutoyo measuring microscope At permanent location (S) Internal procedure IW/KUM/10/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":84,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/10/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"1 mm to 7 mm","cmc":"4 µm"},{"name":"","range":"7,5 mm to 15 mm","cmc":"15 µm"},{"name":"","range":"15,5 mm to 25 mm","cmc":"21 µm"}],"reference_de":"Internes Verfahren IW/KUM/10/01","regulatory_area_de":"Länge","search_de":"Kreisbogennormale (Radienlehren) Kalibrierung — Länge Internes Verfahren; Indirektes Verfahren mit einem Messmikroskop Mitutoyo; Am festen Standort (S) Länge Internes Verfahren Indirektes Verfahren mit einem Messmikroskop Mitutoyo Am festen Standort (S) Internes Verfahren IW/KUM/10/01","technique_de":"Internes Verfahren; Indirektes Verfahren mit einem Messmikroskop Mitutoyo; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit einem Messmikroskop Mitutoyo","Am festen Standort (S)"],"test_object_de":"Kreisbogennormale (Radienlehren)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"1 mm to 7 mm","cmc":"4 µm"},{"name":"","range":"7,5 mm to 15 mm","cmc":"15 µm"},{"name":"","range":"15,5 mm to 25 mm","cmc":"21 µm"}],"reference_zh":"内部程序 IW/KUM/10/01","regulatory_area_zh":"长度","search_zh":"圆弧标准器（半径规） 校准 — 长度 内部程序；使用Mitutoyo测量显微镜的间接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo测量显微镜的间接法 在固定地点 (S) 内部程序 IW/KUM/10/01","technique_zh":"内部程序；使用Mitutoyo测量显微镜的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo测量显微镜的间接法","在固定地点 (S)"],"test_object_zh":"圆弧标准器（半径规）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"1 mm to 7 mm","cmc":"4 µm"},{"name":"","range":"7,5 mm to 15 mm","cmc":"15 µm"},{"name":"","range":"15,5 mm to 25 mm","cmc":"21 µm"}],"reference_cs":"Vnitřní postup IW/KUM/10/01","regulatory_area_cs":"Délka","search_cs":"Etalony kruhových oblouků (rádiusové měrky) Kalibrace — Délka Vnitřní postup; Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo Ve stálé lokalitě (S) Vnitřní postup IW/KUM/10/01","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo","Ve stálé lokalitě (S)"],"test_object_cs":"Etalony kruhových oblouků (rádiusové měrky)"},{"_id":"9645aed78863924c1370346b","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wzorce łuków kołowych (promieniomierze)","test_object_en":"Circular arc standards (radius gauges)","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,1 mm do 7 mm","cmc":"3 µm"},{"name":"","range":"7 mm do 15 mm","cmc":"4 µm"},{"name":"","range":"15 mm do 25 mm","cmc":"13 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"20 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"33 µm"}],"parameters_en":[{"name":"","range":"0,1 mm do 7 mm","cmc":"3 µm"},{"name":"","range":"7 mm do 15 mm","cmc":"4 µm"},{"name":"","range":"15 mm do 25 mm","cmc":"13 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"20 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"33 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu pomiarowego ISD-V300A; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an ISD-V300A measuring microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem mikroskopu pomiarowego ISD-V300A","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an ISD-V300A measuring microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0,1 mm do 7 mm CMC 3 µm\n7 mm do 15 mm CMC 4 µm\n15 mm do 25 mm CMC 13 µm\n25 mm do 50 mm CMC 20 µm\n50 mm do 100 mm CMC 33 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu pomiarowego ISD-V300A; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/23/03","norm_bases":["IW/KUM/23/03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce łuków kołowych (promieniomierze) Wzorcowanie — Długość\nZakres:\n0,1 mm do 7 mm CMC 3 µm\n7 mm do 15 mm CMC 4 µm\n15 mm do 25 mm CMC 13 µm\n25 mm do 50 mm CMC 20 µm\n50 mm do 100 mm CMC 33 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikroskopu pomiarowego ISD-V300A; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/23/03 Wzorce lukow kolowych (promieniomierze) Wzorcowanie — Dlugosc\nZakres:\n0,1 mm do 7 mm CMC 3 µm\n7 mm do 15 mm CMC 4 µm\n15 mm do 25 mm CMC 13 µm\n25 mm do 50 mm CMC 20 µm\n50 mm do 100 mm CMC 33 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem mikroskopu pomiarowego ISD-V300A; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/23/03","search_en":"Circular arc standards (radius gauges) Calibration — Length Internal procedure; Direct method using an ISD-V300A measuring microscope; At permanent location (S) Length Internal procedure Direct method using an ISD-V300A measuring microscope At permanent location (S) Internal procedure IW/KUM/23/03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":85,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/23/03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,1 mm do 7 mm","cmc":"3 µm"},{"name":"","range":"7 mm do 15 mm","cmc":"4 µm"},{"name":"","range":"15 mm do 25 mm","cmc":"13 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"20 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"33 µm"}],"reference_de":"Internes Verfahren IW/KUM/23/03","regulatory_area_de":"Länge","search_de":"Kreisbogennormale (Radienlehren) Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Messmikroskop ISD-V300A; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Messmikroskop ISD-V300A Am festen Standort (S) Internes Verfahren IW/KUM/23/03","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Messmikroskop ISD-V300A; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Messmikroskop ISD-V300A","Am festen Standort (S)"],"test_object_de":"Kreisbogennormale (Radienlehren)","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,1 mm do 7 mm","cmc":"3 µm"},{"name":"","range":"7 mm do 15 mm","cmc":"4 µm"},{"name":"","range":"15 mm do 25 mm","cmc":"13 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"20 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"33 µm"}],"reference_zh":"内部程序 IW/KUM/23/03","regulatory_area_zh":"长度","search_zh":"圆弧标准器（半径规） 校准 — 长度 内部程序；使用ISD-V300A测量显微镜的直接法；在固定地点 (S) 长度 内部程序 使用ISD-V300A测量显微镜的直接法 在固定地点 (S) 内部程序 IW/KUM/23/03","technique_zh":"内部程序；使用ISD-V300A测量显微镜的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ISD-V300A测量显微镜的直接法","在固定地点 (S)"],"test_object_zh":"圆弧标准器（半径规）","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,1 mm do 7 mm","cmc":"3 µm"},{"name":"","range":"7 mm do 15 mm","cmc":"4 µm"},{"name":"","range":"15 mm do 25 mm","cmc":"13 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"20 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"33 µm"}],"reference_cs":"Vnitřní postup IW/KUM/23/03","regulatory_area_cs":"Délka","search_cs":"Etalony kruhových oblouků (rádiusové měrky) Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím měřicího mikroskopu ISD-V300A; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím měřicího mikroskopu ISD-V300A Ve stálé lokalitě (S) Vnitřní postup IW/KUM/23/03","technique_cs":"Vnitřní postup; Přímá metoda s použitím měřicího mikroskopu ISD-V300A; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím měřicího mikroskopu ISD-V300A","Ve stálé lokalitě (S)"],"test_object_cs":"Etalony kruhových oblouků (rádiusové měrky)"},{"_id":"9ec9c09a5c314f1cb889e8f0","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wzorce nastawcze do wymiarów zewnętrznych","test_object_en":"Setting standards for external dimensions","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"25 mm do 50 mm","cmc":"0,5 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,6 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"0,8 µm"}],"parameters_en":[{"name":"","range":"25 mm to 50 mm","cmc":"0,5 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,6 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"0,8 µm"}],"technique":"Procedura wewnętrzna; Metoda porównawcza z zastosowaniem transametru; W stałej lokalizacji (S)","technique_en":"Internal procedure; Comparative method using a transameter; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda porównawcza z zastosowaniem transametru","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Comparative method using a transameter","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n25 mm do 50 mm CMC 0,5 µm\n50 mm do 100 mm CMC 0,6 µm\n100 mm do 150 mm CMC 0,8 µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem transametru; W stałej lokalizacji (S)","reference":"Instrukcja wewnętrzna IW/KUM/02/06","norm_bases":["IW/KUM/02/06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce nastawcze do wymiarów zewnętrznych Wzorcowanie — Długość\nZakres:\n25 mm do 50 mm CMC 0,5 µm\n50 mm do 100 mm CMC 0,6 µm\n100 mm do 150 mm CMC 0,8 µm\nProcedura wewnętrzna; Metoda porównawcza z zastosowaniem transametru; W stałej lokalizacji (S) Instrukcja wewnętrzna IW/KUM/02/06 Wzorce nastawcze do wymiarow zewnetrznych Wzorcowanie — Dlugosc\nZakres:\n25 mm do 50 mm CMC 0,5 µm\n50 mm do 100 mm CMC 0,6 µm\n100 mm do 150 mm CMC 0,8 µm\nProcedura wewnetrzna; Metoda porownawcza z zastosowaniem transametru; W stalej lokalizacji (S) Instrukcja wewnetrzna IW/KUM/02/06","search_en":"Setting standards for external dimensions Calibration — Length Internal procedure; Comparative method using a transameter; At permanent location (S) Length Internal procedure Comparative method using a transameter At permanent location (S) Internal instruction IW/KUM/02/06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":86,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal instruction IW/KUM/02/06","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"25 mm bis 50 mm","cmc":"0,5 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,6 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"0,8 µm"}],"reference_de":"Interne Arbeitsanweisung IW/KUM/02/06","regulatory_area_de":"Länge","search_de":"Einstellnormale für Außenmaße Kalibrierung — Länge Internes Verfahren; Vergleichsverfahren mit einem Transameter; Am festen Standort (S) Länge Internes Verfahren Vergleichsverfahren mit einem Transameter Am festen Standort (S) Interne Arbeitsanweisung IW/KUM/02/06","technique_de":"Internes Verfahren; Vergleichsverfahren mit einem Transameter; Am festen Standort (S)","techniques_de":["Internes Verfahren","Vergleichsverfahren mit einem Transameter","Am festen Standort (S)"],"test_object_de":"Einstellnormale für Außenmaße","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"25 mm 至 50 mm","cmc":"0,5 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,6 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"0,8 µm"}],"reference_zh":"内部作业指导书 IW/KUM/02/06","regulatory_area_zh":"长度","search_zh":"外尺寸校对规 校准 — 长度 内部程序；使用杠杆千分尺的比较法；在固定地点 (S) 长度 内部程序 使用杠杆千分尺的比较法 在固定地点 (S) 内部作业指导书 IW/KUM/02/06","technique_zh":"内部程序；使用杠杆千分尺的比较法；在固定地点 (S)","techniques_zh":["内部程序","使用杠杆千分尺的比较法","在固定地点 (S)"],"test_object_zh":"外尺寸校对规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"25 mm do 50 mm","cmc":"0,5 µm"},{"name":"","range":"50 mm do 100 mm","cmc":"0,6 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"0,8 µm"}],"reference_cs":"Vnitřní instrukce IW/KUM/02/06","regulatory_area_cs":"Délka","search_cs":"Nastavovací etalony pro vnější rozměry Kalibrace — Délka Vnitřní postup; Srovnávací metoda s použitím transametru; Ve stálé lokalitě (S) Délka Vnitřní postup Srovnávací metoda s použitím transametru Ve stálé lokalitě (S) Vnitřní instrukce IW/KUM/02/06","technique_cs":"Vnitřní postup; Srovnávací metoda s použitím transametru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Srovnávací metoda s použitím transametru","Ve stálé lokalitě (S)"],"test_object_cs":"Nastavovací etalony pro vnější rozměry"},{"_id":"bb554df9c0911c35e4c8ed2d","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wzorce nastawcze do wymiarów zewnętrznych","test_object_en":"Setting standards for external dimensions","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"25 mm do 100 mm","cmc":"0,4 µm"},{"name":"","range":"100 mm do 200 mm","cmc":"1,0 µm"},{"name":"","range":"200 mm do 300 mm","cmc":"1,4 µm"},{"name":"","range":"300 mm do 400 mm","cmc":"1,8 µm"},{"name":"","range":"400 mm do 500 mm","cmc":"2,2 µm"}],"parameters_en":[{"name":"","range":"25 mm to 100 mm","cmc":"0,4 µm"},{"name":"","range":"100 mm to 200 mm","cmc":"1,0 µm"},{"name":"","range":"200 mm to 300 mm","cmc":"1,4 µm"},{"name":"","range":"300 mm to 400 mm","cmc":"1,8 µm"},{"name":"","range":"400 mm to 500 mm","cmc":"2,2 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a ULM 520 S-E length measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n25 mm do 100 mm CMC 0,4 µm\n100 mm do 200 mm CMC 1,0 µm\n200 mm do 300 mm CMC 1,4 µm\n300 mm do 400 mm CMC 1,8 µm\n400 mm do 500 mm CMC 2,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/22/04","norm_bases":["IW/KUM/22/04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce nastawcze do wymiarów zewnętrznych Wzorcowanie — Długość\nZakres:\n25 mm do 100 mm CMC 0,4 µm\n100 mm do 200 mm CMC 1,0 µm\n200 mm do 300 mm CMC 1,4 µm\n300 mm do 400 mm CMC 1,8 µm\n400 mm do 500 mm CMC 2,2 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem długościomierza ULM 520 S-E; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/22/04 Wzorce nastawcze do wymiarow zewnetrznych Wzorcowanie — Dlugosc\nZakres:\n25 mm do 100 mm CMC 0,4 µm\n100 mm do 200 mm CMC 1,0 µm\n200 mm do 300 mm CMC 1,4 µm\n300 mm do 400 mm CMC 1,8 µm\n400 mm do 500 mm CMC 2,2 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem dlugosciomierza ULM 520 S-E; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/22/04","search_en":"Setting standards for external dimensions Calibration — Length Internal procedure; Direct method using a ULM 520 S-E length measuring machine; At permanent location (S) Length Internal procedure Direct method using a ULM 520 S-E length measuring machine At permanent location (S) Internal procedure IW/KUM/22/04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":87,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/22/04","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"25 mm to 100 mm","cmc":"0,4 µm"},{"name":"","range":"100 mm to 200 mm","cmc":"1,0 µm"},{"name":"","range":"200 mm to 300 mm","cmc":"1,4 µm"},{"name":"","range":"300 mm to 400 mm","cmc":"1,8 µm"},{"name":"","range":"400 mm to 500 mm","cmc":"2,2 µm"}],"reference_de":"Internes Verfahren IW/KUM/22/04","regulatory_area_de":"Länge","search_de":"Einstellnormale für Außenmaße Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E Am festen Standort (S) Internes Verfahren IW/KUM/22/04","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Längenmessgerät ULM 520 S-E","Am festen Standort (S)"],"test_object_de":"Einstellnormale für Außenmaße","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"25 mm to 100 mm","cmc":"0,4 µm"},{"name":"","range":"100 mm to 200 mm","cmc":"1,0 µm"},{"name":"","range":"200 mm to 300 mm","cmc":"1,4 µm"},{"name":"","range":"300 mm to 400 mm","cmc":"1,8 µm"},{"name":"","range":"400 mm to 500 mm","cmc":"2,2 µm"}],"reference_zh":"内部程序 IW/KUM/22/04","regulatory_area_zh":"长度","search_zh":"外尺寸校对规 校准 — 长度 内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S) 长度 内部程序 使用ULM 520 S-E测长仪的直接法 在固定地点 (S) 内部程序 IW/KUM/22/04","technique_zh":"内部程序；使用ULM 520 S-E测长仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用ULM 520 S-E测长仪的直接法","在固定地点 (S)"],"test_object_zh":"外尺寸校对规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"25 mm to 100 mm","cmc":"0,4 µm"},{"name":"","range":"100 mm to 200 mm","cmc":"1,0 µm"},{"name":"","range":"200 mm to 300 mm","cmc":"1,4 µm"},{"name":"","range":"300 mm to 400 mm","cmc":"1,8 µm"},{"name":"","range":"400 mm to 500 mm","cmc":"2,2 µm"}],"reference_cs":"Vnitřní postup IW/KUM/22/04","regulatory_area_cs":"Délka","search_cs":"Nastavovací etalony pro vnější rozměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím délkoměru ULM 520 S-E Ve stálé lokalitě (S) Vnitřní postup IW/KUM/22/04","technique_cs":"Vnitřní postup; Přímá metoda s použitím délkoměru ULM 520 S-E; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím délkoměru ULM 520 S-E","Ve stálé lokalitě (S)"],"test_object_cs":"Nastavovací etalony pro vnější rozměry"},{"_id":"221f0d2c78326f9a6c43ca3b","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wzorce schodkowe do grubościomierzy ultradźwiękowych","test_object_en":"Step standards for ultrasonic thickness gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– stalowe","range":"0,5 mm do 50 mm","cmc":"3 µm"},{"name":"– stalowe","range":"50 mm do 100 mm","cmc":"5 µm"},{"name":"– stalowe","range":"100 mm do 125 mm","cmc":"6 µm"},{"name":"– aluminiowe","range":"0,5 mm do 50 mm","cmc":"4 µm"},{"name":"– aluminiowe","range":"50 mm do 100 mm","cmc":"6 µm"},{"name":"– aluminiowe","range":"100 mm do 125 mm","cmc":"7 µm"}],"parameters_en":[{"name":"– steel","range":"0,5 mm to 50 mm","cmc":"3 µm"},{"name":"– steel","range":"50 mm to 100 mm","cmc":"5 µm"},{"name":"– steel","range":"100 mm to 125 mm","cmc":"6 µm"},{"name":"– aluminium","range":"0,5 mm to 50 mm","cmc":"4 µm"},{"name":"– aluminium","range":"50 mm to 100 mm","cmc":"6 µm"},{"name":"– aluminium","range":"100 mm to 125 mm","cmc":"7 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometrów zewnętrznych cyfrowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using digital external micrometers; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem mikrometrów zewnętrznych cyfrowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using digital external micrometers","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– stalowe 0,5 mm do 50 mm CMC 3 µm\n– stalowe 50 mm do 100 mm CMC 5 µm\n– stalowe 100 mm do 125 mm CMC 6 µm\n– aluminiowe 0,5 mm do 50 mm CMC 4 µm\n– aluminiowe 50 mm do 100 mm CMC 6 µm\n– aluminiowe 100 mm do 125 mm CMC 7 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometrów zewnętrznych cyfrowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/26/01","norm_bases":["IW/KUM/26/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce schodkowe do grubościomierzy ultradźwiękowych Wzorcowanie — Długość\nZakres:\n– stalowe 0,5 mm do 50 mm CMC 3 µm\n– stalowe 50 mm do 100 mm CMC 5 µm\n– stalowe 100 mm do 125 mm CMC 6 µm\n– aluminiowe 0,5 mm do 50 mm CMC 4 µm\n– aluminiowe 50 mm do 100 mm CMC 6 µm\n– aluminiowe 100 mm do 125 mm CMC 7 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem mikrometrów zewnętrznych cyfrowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/26/01 Wzorce schodkowe do grubosciomierzy ultradzwiekowych Wzorcowanie — Dlugosc\nZakres:\n– stalowe 0,5 mm do 50 mm CMC 3 µm\n– stalowe 50 mm do 100 mm CMC 5 µm\n– stalowe 100 mm do 125 mm CMC 6 µm\n– aluminiowe 0,5 mm do 50 mm CMC 4 µm\n– aluminiowe 50 mm do 100 mm CMC 6 µm\n– aluminiowe 100 mm do 125 mm CMC 7 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem mikrometrow zewnetrznych cyfrowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/26/01","search_en":"Step standards for ultrasonic thickness gauges Calibration — Length Internal procedure; Direct method using digital external micrometers; At permanent location (S) Length Internal procedure Direct method using digital external micrometers At permanent location (S) – steel – steel – steel – aluminium – aluminium – aluminium Internal procedure IW/KUM/26/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":88,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/26/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– aus Stahl","range":"0,5 mm to 50 mm","cmc":"3 µm"},{"name":"– aus Stahl","range":"50 mm to 100 mm","cmc":"5 µm"},{"name":"– aus Stahl","range":"100 mm bis 125 mm","cmc":"6 µm"},{"name":"– aus Aluminium","range":"0,5 mm to 50 mm","cmc":"4 µm"},{"name":"– aus Aluminium","range":"50 mm to 100 mm","cmc":"6 µm"},{"name":"– aus Aluminium","range":"100 mm bis 125 mm","cmc":"7 µm"}],"reference_de":"Internes Verfahren IW/KUM/26/01","regulatory_area_de":"Länge","search_de":"Stufenkörper für Ultraschall-Dickenmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit digitalen Bügelmessschrauben; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit digitalen Bügelmessschrauben Am festen Standort (S) – aus Stahl – aus Stahl – aus Stahl – aus Aluminium – aus Aluminium – aus Aluminium Internes Verfahren IW/KUM/26/01","technique_de":"Internes Verfahren; Direktes Verfahren mit digitalen Bügelmessschrauben; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit digitalen Bügelmessschrauben","Am festen Standort (S)"],"test_object_de":"Stufenkörper für Ultraschall-Dickenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 钢制","range":"0,5 mm to 50 mm","cmc":"3 µm"},{"name":"– 钢制","range":"50 mm to 100 mm","cmc":"5 µm"},{"name":"– 钢制","range":"100 mm 至 125 mm","cmc":"6 µm"},{"name":"– 铝制","range":"0,5 mm to 50 mm","cmc":"4 µm"},{"name":"– 铝制","range":"50 mm to 100 mm","cmc":"6 µm"},{"name":"– 铝制","range":"100 mm 至 125 mm","cmc":"7 µm"}],"reference_zh":"内部程序 IW/KUM/26/01","regulatory_area_zh":"长度","search_zh":"超声测厚仪用阶梯试块 校准 — 长度 内部程序；使用数显外径千分尺的直接法；在固定地点 (S) 长度 内部程序 使用数显外径千分尺的直接法 在固定地点 (S) – 钢制 – 钢制 – 钢制 – 铝制 – 铝制 – 铝制 内部程序 IW/KUM/26/01","technique_zh":"内部程序；使用数显外径千分尺的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用数显外径千分尺的直接法","在固定地点 (S)"],"test_object_zh":"超声测厚仪用阶梯试块","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– ocelové","range":"0,5 mm to 50 mm","cmc":"3 µm"},{"name":"– ocelové","range":"50 mm to 100 mm","cmc":"5 µm"},{"name":"– ocelové","range":"100 mm do 125 mm","cmc":"6 µm"},{"name":"– hliníkové","range":"0,5 mm to 50 mm","cmc":"4 µm"},{"name":"– hliníkové","range":"50 mm to 100 mm","cmc":"6 µm"},{"name":"– hliníkové","range":"100 mm do 125 mm","cmc":"7 µm"}],"reference_cs":"Vnitřní postup IW/KUM/26/01","regulatory_area_cs":"Délka","search_cs":"Stupňové etalony pro ultrazvukové tloušťkoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím digitálních mikrometrů pro vnější měření; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím digitálních mikrometrů pro vnější měření Ve stálé lokalitě (S) – ocelové – ocelové – ocelové – hliníkové – hliníkové – hliníkové Vnitřní postup IW/KUM/26/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím digitálních mikrometrů pro vnější měření; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím digitálních mikrometrů pro vnější měření","Ve stálé lokalitě (S)"],"test_object_cs":"Stupňové etalony pro ultrazvukové tloušťkoměry"},{"_id":"b83526912a07ce8c1daae020","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wzorce zarysu gwintu","test_object_en":"Thread profile standards","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– metrycznego","range":"0,25 mm do 6 mm","cmc":"4 µm"},{"name":"– calowego","range":"4 do 62 zwoje na cal","cmc":"4 µm"}],"parameters_en":[{"name":"– metric","range":"0,25 mm to 6 mm","cmc":"4 µm"},{"name":"– inch","range":"4 to 62 threads per inch","cmc":"4 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using a Mitutoyo measuring microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using a Mitutoyo measuring microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– metrycznego 0,25 mm do 6 mm CMC 4 µm\n– calowego 4 do 62 zwoje na cal CMC 4 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/10/02","norm_bases":["IW/KUM/10/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce zarysu gwintu Wzorcowanie — Długość\nZakres:\n– metrycznego 0,25 mm do 6 mm CMC 4 µm\n– calowego 4 do 62 zwoje na cal CMC 4 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/10/02 Wzorce zarysu gwintu Wzorcowanie — Dlugosc\nZakres:\n– metrycznego 0,25 mm do 6 mm CMC 4 µm\n– calowego 4 do 62 zwoje na cal CMC 4 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem mikroskopu pomiarowego Mitutoyo; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/10/02","search_en":"Thread profile standards Calibration — Length Internal procedure; Indirect method using a Mitutoyo measuring microscope; At permanent location (S) Length Internal procedure Indirect method using a Mitutoyo measuring microscope At permanent location (S) – metric – inch Internal procedure IW/KUM/10/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":89,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/10/02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– metrisches Gewinde","range":"0,25 mm to 6 mm","cmc":"4 µm"},{"name":"– Zollgewinde","range":"4 to 62 threads per inch","cmc":"4 µm"}],"reference_de":"Internes Verfahren IW/KUM/10/02","regulatory_area_de":"Länge","search_de":"Gewindeprofilnormale Kalibrierung — Länge Internes Verfahren; Indirektes Verfahren mit einem Messmikroskop Mitutoyo; Am festen Standort (S) Länge Internes Verfahren Indirektes Verfahren mit einem Messmikroskop Mitutoyo Am festen Standort (S) – metrisches Gewinde – Zollgewinde Internes Verfahren IW/KUM/10/02","technique_de":"Internes Verfahren; Indirektes Verfahren mit einem Messmikroskop Mitutoyo; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit einem Messmikroskop Mitutoyo","Am festen Standort (S)"],"test_object_de":"Gewindeprofilnormale","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 米制螺纹","range":"0,25 mm to 6 mm","cmc":"4 µm"},{"name":"– 英制螺纹","range":"4 to 62 threads per inch","cmc":"4 µm"}],"reference_zh":"内部程序 IW/KUM/10/02","regulatory_area_zh":"长度","search_zh":"螺纹牙型标准器 校准 — 长度 内部程序；使用Mitutoyo测量显微镜的间接法；在固定地点 (S) 长度 内部程序 使用Mitutoyo测量显微镜的间接法 在固定地点 (S) – 米制螺纹 – 英制螺纹 内部程序 IW/KUM/10/02","technique_zh":"内部程序；使用Mitutoyo测量显微镜的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用Mitutoyo测量显微镜的间接法","在固定地点 (S)"],"test_object_zh":"螺纹牙型标准器","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– metrického","range":"0,25 mm to 6 mm","cmc":"4 µm"},{"name":"– palcového","range":"4 to 62 threads per inch","cmc":"4 µm"}],"reference_cs":"Vnitřní postup IW/KUM/10/02","regulatory_area_cs":"Délka","search_cs":"Etalony profilu závitu Kalibrace — Délka Vnitřní postup; Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo; Ve stálé lokalitě (S) Délka Vnitřní postup Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo Ve stálé lokalitě (S) – metrického – palcového Vnitřní postup IW/KUM/10/02","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím měřicího mikroskopu Mitutoyo","Ve stálé lokalitě (S)"],"test_object_cs":"Etalony profilu závitu"},{"_id":"5b9b5beb21b21cb2bd4450af","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wysokościomierze cyfrowe","test_object_en":"Digital height gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"– rozdzielczość 0,01 mm","range":"0 mm do 1000 mm","cmc":"Q[5,86; 3,24∙L] µm"},{"name":"– rozdzielczość 0,005 mm","range":"0 mm do 1000 mm","cmc":"Q[3,03; 3,24∙L] µm"},{"name":"– rozdzielczość 0,001 mm","range":"0 mm do 1000 mm","cmc":"Q[1,11; 3,24∙L] µm"},{"name":"– rozdzielczość 0,0005 mm","range":"0 mm do 1000 mm","cmc":"Q[1,00; 3,24∙L] µm"},{"name":"– rozdzielczość 0,0001 mm","range":"0 mm do 1000 mm","cmc":"Q[0,95; 3,24∙L] µm"}],"parameters_en":[{"name":"– resolution 0,01 mm","range":"0 mm to 1000 mm","cmc":"Q[5,86; 3,24∙L] µm"},{"name":"– resolution 0,005 mm","range":"0 mm to 1000 mm","cmc":"Q[3,03; 3,24∙L] µm"},{"name":"– resolution 0,001 mm","range":"0 mm to 1000 mm","cmc":"Q[1,11; 3,24∙L] µm"},{"name":"– resolution 0,0005 mm","range":"0 mm to 1000 mm","cmc":"Q[1,00; 3,24∙L] µm"},{"name":"– resolution 0,0001 mm","range":"0 mm to 1000 mm","cmc":"Q[0,95; 3,24∙L] µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n– rozdzielczość 0,01 mm 0 mm do 1000 mm CMC Q[5,86; 3,24∙L] µm\n– rozdzielczość 0,005 mm 0 mm do 1000 mm CMC Q[3,03; 3,24∙L] µm\n– rozdzielczość 0,001 mm 0 mm do 1000 mm CMC Q[1,11; 3,24∙L] µm\n– rozdzielczość 0,0005 mm 0 mm do 1000 mm CMC Q[1,00; 3,24∙L] µm\n– rozdzielczość 0,0001 mm 0 mm do 1000 mm CMC Q[0,95; 3,24∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna IW/KUM/12/04","norm_bases":["IW/KUM/12/04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":true,"location_of_activity":"S, P","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Wysokościomierze cyfrowe Wzorcowanie — Długość\nZakres:\n– rozdzielczość 0,01 mm 0 mm do 1000 mm CMC Q[5,86; 3,24∙L] µm\n– rozdzielczość 0,005 mm 0 mm do 1000 mm CMC Q[3,03; 3,24∙L] µm\n– rozdzielczość 0,001 mm 0 mm do 1000 mm CMC Q[1,11; 3,24∙L] µm\n– rozdzielczość 0,0005 mm 0 mm do 1000 mm CMC Q[1,00; 3,24∙L] µm\n– rozdzielczość 0,0001 mm 0 mm do 1000 mm CMC Q[0,95; 3,24∙L] µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna IW/KUM/12/04 Wysokosciomierze cyfrowe Wzorcowanie — Dlugosc\nZakres:\n– rozdzielczosc 0,01 mm 0 mm do 1000 mm CMC Q[5,86; 3,24∙L] µm\n– rozdzielczosc 0,005 mm 0 mm do 1000 mm CMC Q[3,03; 3,24∙L] µm\n– rozdzielczosc 0,001 mm 0 mm do 1000 mm CMC Q[1,11; 3,24∙L] µm\n– rozdzielczosc 0,0005 mm 0 mm do 1000 mm CMC Q[1,00; 3,24∙L] µm\n– rozdzielczosc 0,0001 mm 0 mm do 1000 mm CMC Q[0,95; 3,24∙L] µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna IW/KUM/12/04","search_en":"Digital height gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) and outside of it (P) Length Internal procedure Direct method using gauge blocks At permanent location (S) and outside of it (P) – resolution 0,01 mm – resolution 0,005 mm – resolution 0,001 mm – resolution 0,0005 mm – resolution 0,0001 mm Internal procedure IW/KUM/12/04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":90,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/12/04","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"– Auflösung 0,01 mm","range":"0 mm bis 1000 mm","cmc":"Q[5,86; 3,24∙L] µm"},{"name":"– Auflösung 0,005 mm","range":"0 mm bis 1000 mm","cmc":"Q[3,03; 3,24∙L] µm"},{"name":"– Auflösung 0,001 mm","range":"0 mm bis 1000 mm","cmc":"Q[1,11; 3,24∙L] µm"},{"name":"– Auflösung 0,0005 mm","range":"0 mm bis 1000 mm","cmc":"Q[1,00; 3,24∙L] µm"},{"name":"– Auflösung 0,0001 mm","range":"0 mm bis 1000 mm","cmc":"Q[0,95; 3,24∙L] µm"}],"reference_de":"Internes Verfahren IW/KUM/12/04","regulatory_area_de":"Länge","search_de":"Digitale Höhenmessgeräte Kalibrierung — Länge Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) und außerhalb (P) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) und außerhalb (P) – Auflösung 0,01 mm – Auflösung 0,005 mm – Auflösung 0,001 mm – Auflösung 0,0005 mm – Auflösung 0,0001 mm Internes Verfahren IW/KUM/12/04","technique_de":"Internes Verfahren; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Digitale Höhenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"– 分辨力 0,01 mm","range":"0 mm 至 1000 mm","cmc":"Q[5,86; 3,24∙L] µm"},{"name":"– 分辨力 0,005 mm","range":"0 mm 至 1000 mm","cmc":"Q[3,03; 3,24∙L] µm"},{"name":"– 分辨力 0,001 mm","range":"0 mm 至 1000 mm","cmc":"Q[1,11; 3,24∙L] µm"},{"name":"– 分辨力 0,0005 mm","range":"0 mm 至 1000 mm","cmc":"Q[1,00; 3,24∙L] µm"},{"name":"– 分辨力 0,0001 mm","range":"0 mm 至 1000 mm","cmc":"Q[0,95; 3,24∙L] µm"}],"reference_zh":"内部程序 IW/KUM/12/04","regulatory_area_zh":"长度","search_zh":"数显高度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 及固定地点以外 (P) 长度 内部程序 使用量块的直接法 在固定地点 (S) 及固定地点以外 (P) – 分辨力 0,01 mm – 分辨力 0,005 mm – 分辨力 0,001 mm – 分辨力 0,0005 mm – 分辨力 0,0001 mm 内部程序 IW/KUM/12/04","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"数显高度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"– rozlišení 0,01 mm","range":"0 mm do 1000 mm","cmc":"Q[5,86; 3,24∙L] µm"},{"name":"– rozlišení 0,005 mm","range":"0 mm do 1000 mm","cmc":"Q[3,03; 3,24∙L] µm"},{"name":"– rozlišení 0,001 mm","range":"0 mm do 1000 mm","cmc":"Q[1,11; 3,24∙L] µm"},{"name":"– rozlišení 0,0005 mm","range":"0 mm do 1000 mm","cmc":"Q[1,00; 3,24∙L] µm"},{"name":"– rozlišení 0,0001 mm","range":"0 mm do 1000 mm","cmc":"Q[0,95; 3,24∙L] µm"}],"reference_cs":"Vnitřní postup IW/KUM/12/04","regulatory_area_cs":"Délka","search_cs":"Digitální výškoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; V trvalé lokalitě (S) i mimo ni (P) Délka Vnitřní postup Přímá metoda s použitím koncových měrek V trvalé lokalitě (S) i mimo ni (P) – rozlišení 0,01 mm – rozlišení 0,005 mm – rozlišení 0,001 mm – rozlišení 0,0005 mm – rozlišení 0,0001 mm Vnitřní postup IW/KUM/12/04","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Digitální výškoměry"},{"_id":"282996f3b99ce8ce18f90552","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wysokościomierze do pomiaru wysokości kół pojazdów","test_object_en":"Height gauges for measuring vehicle wheel height","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 1000 mm","cmc":"0,5 mm"}],"parameters_en":[{"name":"","range":"0 mm to 1000 mm","cmc":"0,5 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 1000 mm CMC 0,5 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/01/03","norm_bases":["IW/KUM/01/03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wysokościomierze do pomiaru wysokości kół pojazdów Wzorcowanie — Długość\n0 mm do 1000 mm CMC 0,5 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/01/03 Wysokosciomierze do pomiaru wysokosci kol pojazdow Wzorcowanie — Dlugosc\n0 mm do 1000 mm CMC 0,5 mm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/01/03","search_en":"Height gauges for measuring vehicle wheel height Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/01/03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":91,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/01/03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 1000 mm","cmc":"0,5 mm"}],"reference_de":"Internes Verfahren IW/KUM/01/03","regulatory_area_de":"Länge","search_de":"Höhenmessgeräte zur Messung der Radhöhe von Fahrzeugen Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/01/03","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Höhenmessgeräte zur Messung der Radhöhe von Fahrzeugen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 1000 mm","cmc":"0,5 mm"}],"reference_zh":"内部程序 IW/KUM/01/03","regulatory_area_zh":"长度","search_zh":"车轮高度测量用高度计 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/01/03","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"车轮高度测量用高度计","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 1000 mm","cmc":"0,5 mm"}],"reference_cs":"Vnitřní postup IW/KUM/01/03","regulatory_area_cs":"Délka","search_cs":"Výškoměry pro měření výšky kol vozidel Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/01/03","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Výškoměry pro měření výšky kol vozidel"},{"_id":"57a0f8d630cc08f755baad42","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Wysokościomierze suwmiarkowe","test_object_en":"Vernier height gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"18 µm"},{"name":"","range":"0 mm do 750 mm","cmc":"22 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"29 µm"}],"parameters_en":[{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm to 600 mm","cmc":"18 µm"},{"name":"","range":"0 mm do 750 mm","cmc":"22 µm"},{"name":"","range":"0 mm to 1000 mm","cmc":"29 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 300 mm CMC 11 µm\n0 mm do 600 mm CMC 18 µm\n0 mm do 750 mm CMC 22 µm\n0 mm do 1000 mm CMC 29 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/01/01","norm_bases":["IW/KUM/01/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wysokościomierze suwmiarkowe Wzorcowanie — Długość\nZakres:\n0 mm do 300 mm CMC 11 µm\n0 mm do 600 mm CMC 18 µm\n0 mm do 750 mm CMC 22 µm\n0 mm do 1000 mm CMC 29 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/01/01 Wysokosciomierze suwmiarkowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 300 mm CMC 11 µm\n0 mm do 600 mm CMC 18 µm\n0 mm do 750 mm CMC 22 µm\n0 mm do 1000 mm CMC 29 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/01/01","search_en":"Vernier height gauges Calibration — Length Internal procedure; Direct method using gauge blocks; At permanent location (S) Length Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/01/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":92,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/01/01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm bis 600 mm","cmc":"18 µm"},{"name":"","range":"0 mm do 750 mm","cmc":"22 µm"},{"name":"","range":"0 mm bis 1000 mm","cmc":"29 µm"}],"reference_de":"Internes Verfahren IW/KUM/01/01","regulatory_area_de":"Länge","search_de":"Höhenmessschieber Kalibrierung — Länge Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/01/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Höhenmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm 至 600 mm","cmc":"18 µm"},{"name":"","range":"0 mm do 750 mm","cmc":"22 µm"},{"name":"","range":"0 mm 至 1000 mm","cmc":"29 µm"}],"reference_zh":"内部程序 IW/KUM/01/01","regulatory_area_zh":"长度","search_zh":"游标高度尺 校准 — 长度 内部程序；使用量块的直接法；在固定地点 (S) 长度 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/01/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"游标高度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 300 mm","cmc":"11 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"18 µm"},{"name":"","range":"0 mm do 750 mm","cmc":"22 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"29 µm"}],"reference_cs":"Vnitřní postup IW/KUM/01/01","regulatory_area_cs":"Délka","search_cs":"Posuvné výškoměry Kalibrace — Délka Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/01/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Posuvné výškoměry"},{"_id":"611e526034b49d1abf473700","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Kątomierze uniwersalne analogowe","test_object_en":"Analogue universal protractors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"4 x 90°","cmc":"3,0'"}],"parameters_en":[{"name":"","range":"4 x 90°","cmc":"3,0'"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n4 x 90° CMC 3,0'\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/03/01","norm_bases":["IW/KUM/03/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątomierze uniwersalne analogowe Wzorcowanie — Kąt\n4 x 90° CMC 3,0'\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/03/01 Katomierze uniwersalne analogowe Wzorcowanie — Kat\n4 x 90° CMC 3,0'\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/03/01","search_en":"Analogue universal protractors Calibration — Angle Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Angle Internal procedure Direct method using angle gauge blocks At permanent location (S) Internal procedure IW/KUM/03/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":93,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/03/01","methodology_de":"Kalibrierung — Winkel","reference_de":"Internes Verfahren IW/KUM/03/01","regulatory_area_de":"Winkel","search_de":"Analoge Universalwinkelmesser Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Winkelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/03/01","technique_de":"Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Analoge Universalwinkelmesser","methodology_zh":"校准 — 角度","reference_zh":"内部程序 IW/KUM/03/01","regulatory_area_zh":"角度","search_zh":"模拟万能角度尺 校准 — 角度 内部程序；使用角度量块的直接法；在固定地点 (S) 角度 内部程序 使用角度量块的直接法 在固定地点 (S) 内部程序 IW/KUM/03/01","technique_zh":"内部程序；使用角度量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度量块的直接法","在固定地点 (S)"],"test_object_zh":"模拟万能角度尺","methodology_cs":"Kalibrace — Úhel","reference_cs":"Vnitřní postup IW/KUM/03/01","regulatory_area_cs":"Úhel","search_cs":"Analogové univerzální úhloměry Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlových koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/03/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlových koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové univerzální úhloměry"},{"_id":"3ead6cea808dceb0b62fae85","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Kątomierze uniwersalne cyfrowe","test_object_en":"Digital universal protractors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 360°","cmc":"1,5'"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"1,5'"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 360° CMC 1,5'\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/03/01","norm_bases":["IW/KUM/03/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątomierze uniwersalne cyfrowe Wzorcowanie — Kąt\n0° do 360° CMC 1,5'\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/03/01 Katomierze uniwersalne cyfrowe Wzorcowanie — Kat\n0° do 360° CMC 1,5'\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/03/01","search_en":"Digital universal protractors Calibration — Angle Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Angle Internal procedure Direct method using angle gauge blocks At permanent location (S) Internal procedure IW/KUM/03/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":94,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/03/01","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° bis 360°","cmc":"1,5'"}],"reference_de":"Internes Verfahren IW/KUM/03/01","regulatory_area_de":"Winkel","search_de":"Digitale Universalwinkelmesser Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Winkelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/03/01","technique_de":"Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Digitale Universalwinkelmesser","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"1,5'"}],"reference_zh":"内部程序 IW/KUM/03/01","regulatory_area_zh":"角度","search_zh":"数显万能角度尺 校准 — 角度 内部程序；使用角度量块的直接法；在固定地点 (S) 角度 内部程序 使用角度量块的直接法 在固定地点 (S) 内部程序 IW/KUM/03/01","technique_zh":"内部程序；使用角度量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度量块的直接法","在固定地点 (S)"],"test_object_zh":"数显万能角度尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° do 360°","cmc":"1,5'"}],"reference_cs":"Vnitřní postup IW/KUM/03/01","regulatory_area_cs":"Úhel","search_cs":"Digitální univerzální úhloměry Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlových koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/03/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlových koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální univerzální úhloměry"},{"_id":"d9aa47e1672a1a06ec2dfa11","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Kątomierze cyfrowe","test_object_en":"Digital protractors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 360°","cmc":"0,04°"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"0,04°"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem pryzmy kątowej; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an angle prism; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem pryzmy kątowej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an angle prism","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 360° CMC 0,04°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem pryzmy kątowej; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/03/02","norm_bases":["IW/KUM/03/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątomierze cyfrowe Wzorcowanie — Kąt\n0° do 360° CMC 0,04°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem pryzmy kątowej; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/03/02 Katomierze cyfrowe Wzorcowanie — Kat\n0° do 360° CMC 0,04°\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem pryzmy katowej; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/03/02","search_en":"Digital protractors Calibration — Angle Internal procedure; Direct method using an angle prism; At permanent location (S) Angle Internal procedure Direct method using an angle prism At permanent location (S) Internal procedure IW/KUM/03/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":95,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/03/02","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° bis 360°","cmc":"0,04°"}],"reference_de":"Internes Verfahren IW/KUM/03/02","regulatory_area_de":"Winkel","search_de":"Digitale Winkelmesser Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit einem Winkelprisma; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit einem Winkelprisma Am festen Standort (S) Internes Verfahren IW/KUM/03/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einem Winkelprisma; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem Winkelprisma","Am festen Standort (S)"],"test_object_de":"Digitale Winkelmesser","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"0,04°"}],"reference_zh":"内部程序 IW/KUM/03/02","regulatory_area_zh":"角度","search_zh":"数显角度尺 校准 — 角度 内部程序；使用角度棱体的直接法；在固定地点 (S) 角度 内部程序 使用角度棱体的直接法 在固定地点 (S) 内部程序 IW/KUM/03/02","technique_zh":"内部程序；使用角度棱体的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度棱体的直接法","在固定地点 (S)"],"test_object_zh":"数显角度尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° do 360°","cmc":"0,04°"}],"reference_cs":"Vnitřní postup IW/KUM/03/02","regulatory_area_cs":"Úhel","search_cs":"Digitální úhloměry Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlového hranolu; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlového hranolu Ve stálé lokalitě (S) Vnitřní postup IW/KUM/03/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlového hranolu; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlového hranolu","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úhloměry"},{"_id":"da8319cc04cd6dd2a43bad79","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Kątomierze traserskie","test_object_en":"Marking-out protractors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 180°","cmc":"0,12°"}],"parameters_en":[{"name":"","range":"0° to 180°","cmc":"0,12°"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 180° CMC 0,12°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/03/01","norm_bases":["IW/KUM/03/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątomierze traserskie Wzorcowanie — Kąt\n0° do 180° CMC 0,12°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/03/01 Katomierze traserskie Wzorcowanie — Kat\n0° do 180° CMC 0,12°\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/03/01","search_en":"Marking-out protractors Calibration — Angle Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Angle Internal procedure Direct method using angle gauge blocks At permanent location (S) Internal procedure IW/KUM/03/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":96,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/03/01","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° to 180°","cmc":"0,12°"}],"reference_de":"Internes Verfahren IW/KUM/03/01","regulatory_area_de":"Winkel","search_de":"Anreißwinkelmesser Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Winkelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/03/01","technique_de":"Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Anreißwinkelmesser","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° to 180°","cmc":"0,12°"}],"reference_zh":"内部程序 IW/KUM/03/01","regulatory_area_zh":"角度","search_zh":"划线角度尺 校准 — 角度 内部程序；使用角度量块的直接法；在固定地点 (S) 角度 内部程序 使用角度量块的直接法 在固定地点 (S) 内部程序 IW/KUM/03/01","technique_zh":"内部程序；使用角度量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度量块的直接法","在固定地点 (S)"],"test_object_zh":"划线角度尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° to 180°","cmc":"0,12°"}],"reference_cs":"Vnitřní postup IW/KUM/03/01","regulatory_area_cs":"Úhel","search_cs":"Rýsovací úhloměry Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlových koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/03/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlových koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Rýsovací úhloměry"},{"_id":"8a31a241e42d3965e362ba63","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Kątowniki 90° dwuramienne","test_object_en":"90° two-leg squares","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"długość dłuższego ramienia; – płaskość","range":"40 mm do 500 mm","cmc":"2 µm"},{"name":"długość dłuższego ramienia; – prostoliniowość","range":"40 mm do 500 mm","cmc":"1 µm"},{"name":"długość dłuższego ramienia; – równoległość","range":"40 mm do 500 mm","cmc":"1,4 µm"},{"name":"długość dłuższego ramienia; – prostopadłość","range":"40 mm do 500 mm","cmc":"1,1 µm"}],"parameters_en":[{"name":"longer leg length; – flatness","range":"40 mm to 500 mm","cmc":"2 µm"},{"name":"longer leg length; – straightness","range":"40 mm to 500 mm","cmc":"1 µm"},{"name":"longer leg length; – parallelism","range":"40 mm to 500 mm","cmc":"1,4 µm"},{"name":"longer leg length; – perpendicularity","range":"40 mm to 500 mm","cmc":"1,1 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\nZakres:\ndługość dłuższego ramienia; – płaskość 40 mm do 500 mm CMC 2 µm\ndługość dłuższego ramienia; – prostoliniowość 40 mm do 500 mm CMC 1 µm\ndługość dłuższego ramienia; – równoległość 40 mm do 500 mm CMC 1,4 µm\ndługość dłuższego ramienia; – prostopadłość 40 mm do 500 mm CMC 1,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/04/01","norm_bases":["IW/KUM/04/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątowniki 90° dwuramienne Wzorcowanie — Kąt\nZakres:\ndługość dłuższego ramienia; – płaskość 40 mm do 500 mm CMC 2 µm\ndługość dłuższego ramienia; – prostoliniowość 40 mm do 500 mm CMC 1 µm\ndługość dłuższego ramienia; – równoległość 40 mm do 500 mm CMC 1,4 µm\ndługość dłuższego ramienia; – prostopadłość 40 mm do 500 mm CMC 1,1 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/04/01 Katowniki 90° dwuramienne Wzorcowanie — Kat\nZakres:\ndlugosc dluzszego ramienia; – plaskosc 40 mm do 500 mm CMC 2 µm\ndlugosc dluzszego ramienia; – prostoliniowosc 40 mm do 500 mm CMC 1 µm\ndlugosc dluzszego ramienia; – rownoleglosc 40 mm do 500 mm CMC 1,4 µm\ndlugosc dluzszego ramienia; – prostopadlosc 40 mm do 500 mm CMC 1,1 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/04/01","search_en":"90° two-leg squares Calibration — Angle Internal procedure; Direct method using gauge blocks; At permanent location (S) Angle Internal procedure Direct method using gauge blocks At permanent location (S) longer leg length; – flatness longer leg length; – straightness longer leg length; – parallelism longer leg length; – perpendicularity Internal procedure IW/KUM/04/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":97,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/04/01","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"Länge des längeren Schenkels; – Ebenheit","range":"40 mm to 500 mm","cmc":"2 µm"},{"name":"Länge des längeren Schenkels; – Geradheit","range":"40 mm to 500 mm","cmc":"1 µm"},{"name":"Länge des längeren Schenkels; – Parallelität","range":"40 mm to 500 mm","cmc":"1,4 µm"},{"name":"Länge des längeren Schenkels; – Rechtwinkligkeit","range":"40 mm to 500 mm","cmc":"1,1 µm"}],"reference_de":"Internes Verfahren IW/KUM/04/01","regulatory_area_de":"Winkel","search_de":"Zweischenklige 90°-Anschlagwinkel Kalibrierung — Winkel Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Länge des längeren Schenkels; – Ebenheit Länge des längeren Schenkels; – Geradheit Länge des längeren Schenkels; – Parallelität Länge des längeren Schenkels; – Rechtwinkligkeit Internes Verfahren IW/KUM/04/01","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Zweischenklige 90°-Anschlagwinkel","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"长边长度；– 平面度","range":"40 mm to 500 mm","cmc":"2 µm"},{"name":"长边长度；– 直线度","range":"40 mm to 500 mm","cmc":"1 µm"},{"name":"长边长度；– 平行度","range":"40 mm to 500 mm","cmc":"1,4 µm"},{"name":"长边长度；– 垂直度","range":"40 mm to 500 mm","cmc":"1,1 µm"}],"reference_zh":"内部程序 IW/KUM/04/01","regulatory_area_zh":"角度","search_zh":"90° 宽座直角尺 校准 — 角度 内部程序；使用量块的直接法；在固定地点 (S) 角度 内部程序 使用量块的直接法 在固定地点 (S) 长边长度；– 平面度 长边长度；– 直线度 长边长度；– 平行度 长边长度；– 垂直度 内部程序 IW/KUM/04/01","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"90° 宽座直角尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"délka delšího ramene; – rovinnost","range":"40 mm to 500 mm","cmc":"2 µm"},{"name":"délka delšího ramene; – přímost","range":"40 mm to 500 mm","cmc":"1 µm"},{"name":"délka delšího ramene; – rovnoběžnost","range":"40 mm to 500 mm","cmc":"1,4 µm"},{"name":"délka delšího ramene; – kolmost","range":"40 mm to 500 mm","cmc":"1,1 µm"}],"reference_cs":"Vnitřní postup IW/KUM/04/01","regulatory_area_cs":"Úhel","search_cs":"Dvouramenné úhelníky 90° Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) délka delšího ramene; – rovinnost délka delšího ramene; – přímost délka delšího ramene; – rovnoběžnost délka delšího ramene; – kolmost Vnitřní postup IW/KUM/04/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Dvouramenné úhelníky 90°"},{"_id":"15c5c73a5f83e6081937cffd","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Kątowniki 90° walcowe","test_object_en":"90° cylindrical squares","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0 mm do 400 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"","range":"0 mm to 400 mm","cmc":"1,0 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem czujnika indukcyjnego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using an inductive probe; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem czujnika indukcyjnego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using an inductive probe","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0 mm do 400 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem czujnika indukcyjnego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/15/01","norm_bases":["IW/KUM/15/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątowniki 90° walcowe Wzorcowanie — Kąt\n0 mm do 400 mm CMC 1,0 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem czujnika indukcyjnego; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/15/01 Katowniki 90° walcowe Wzorcowanie — Kat\n0 mm do 400 mm CMC 1,0 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem czujnika indukcyjnego; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/15/01","search_en":"90° cylindrical squares Calibration — Angle Internal procedure; Indirect method using an inductive probe; At permanent location (S) Angle Internal procedure Indirect method using an inductive probe At permanent location (S) Internal procedure IW/KUM/15/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":98,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/15/01","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0 mm to 400 mm","cmc":"1,0 µm"}],"reference_de":"Internes Verfahren IW/KUM/15/01","regulatory_area_de":"Winkel","search_de":"90°-Zylinderwinkel Kalibrierung — Winkel Internes Verfahren; Indirektes Verfahren mit einem induktiven Messtaster; Am festen Standort (S) Winkel Internes Verfahren Indirektes Verfahren mit einem induktiven Messtaster Am festen Standort (S) Internes Verfahren IW/KUM/15/01","technique_de":"Internes Verfahren; Indirektes Verfahren mit einem induktiven Messtaster; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit einem induktiven Messtaster","Am festen Standort (S)"],"test_object_de":"90°-Zylinderwinkel","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0 mm to 400 mm","cmc":"1,0 µm"}],"reference_zh":"内部程序 IW/KUM/15/01","regulatory_area_zh":"角度","search_zh":"90°圆柱角尺 校准 — 角度 内部程序；使用电感测头的间接法；在固定地点 (S) 角度 内部程序 使用电感测头的间接法 在固定地点 (S) 内部程序 IW/KUM/15/01","technique_zh":"内部程序；使用电感测头的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用电感测头的间接法","在固定地点 (S)"],"test_object_zh":"90°圆柱角尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0 mm to 400 mm","cmc":"1,0 µm"}],"reference_cs":"Vnitřní postup IW/KUM/15/01","regulatory_area_cs":"Úhel","search_cs":"Válcové úhelníky 90° Kalibrace — Úhel Vnitřní postup; Nepřímá metoda s použitím indukčního snímače; Ve stálé lokalitě (S) Úhel Vnitřní postup Nepřímá metoda s použitím indukčního snímače Ve stálé lokalitě (S) Vnitřní postup IW/KUM/15/01","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím indukčního snímače; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím indukčního snímače","Ve stálé lokalitě (S)"],"test_object_cs":"Válcové úhelníky 90°"},{"_id":"90b38f81fcac0484eda86e83","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Optyczne poziomnice kątowe","test_object_en":"Optical angle levels","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"– błąd ustawienia wskaz. zerowego","range":"-120° do 120°","cmc":"0,2 dz. el."},{"name":"– błąd wartości działki elementarnej","range":"-120° do 120°","cmc":"4″"},{"name":"– błąd pomiaru w całym zakresie","range":"-120° do 120°","cmc":"12″"}],"parameters_en":[{"name":"– zero setting error","range":"-120° to 120°","cmc":"0,2 dz. el."},{"name":"– scale interval value error","range":"-120° to 120°","cmc":"4″"},{"name":"– measurement error over the full range","range":"-120° to 120°","cmc":"12″"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using an optical dividing head; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using an optical dividing head","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\nZakres:\n– błąd ustawienia wskaz. zerowego -120° do 120° CMC 0,2 dz. el.\n– błąd wartości działki elementarnej -120° do 120° CMC 4″\n– błąd pomiaru w całym zakresie -120° do 120° CMC 12″\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/21/01","norm_bases":["IW/KUM/21/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Optyczne poziomnice kątowe Wzorcowanie — Kąt\nZakres:\n– błąd ustawienia wskaz. zerowego -120° do 120° CMC 0,2 dz. el.\n– błąd wartości działki elementarnej -120° do 120° CMC 4″\n– błąd pomiaru w całym zakresie -120° do 120° CMC 12″\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/21/01 Optyczne poziomnice katowe Wzorcowanie — Kat\nZakres:\n– blad ustawienia wskaz. zerowego -120° do 120° CMC 0,2 dz. el.\n– blad wartosci dzialki elementarnej -120° do 120° CMC 4″\n– blad pomiaru w calym zakresie -120° do 120° CMC 12″\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem optycznej glowicy podzialowej; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/21/01","search_en":"Optical angle levels Calibration — Angle Internal procedure; Direct method using an optical dividing head; At permanent location (S) Angle Internal procedure Direct method using an optical dividing head At permanent location (S) – zero setting error – scale interval value error – measurement error over the full range Internal procedure IW/KUM/21/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":99,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/21/01","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"– Nullpunkteinstellfehler","range":"-120° to 120°","cmc":"0,2 dz. el."},{"name":"– Fehler des Skalenteilungswerts","range":"-120° to 120°","cmc":"4″"},{"name":"– Messfehler im gesamten Bereich","range":"-120° to 120°","cmc":"12″"}],"reference_de":"Internes Verfahren IW/KUM/21/01","regulatory_area_de":"Winkel","search_de":"Optische Winkellibellen Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit einem optischen Teilkopf; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit einem optischen Teilkopf Am festen Standort (S) – Nullpunkteinstellfehler – Fehler des Skalenteilungswerts – Messfehler im gesamten Bereich Internes Verfahren IW/KUM/21/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einem optischen Teilkopf; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem optischen Teilkopf","Am festen Standort (S)"],"test_object_de":"Optische Winkellibellen","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"– 零位示值设定误差","range":"-120° to 120°","cmc":"0,2 dz. el."},{"name":"– 分度值误差","range":"-120° to 120°","cmc":"4″"},{"name":"– 全量程测量误差","range":"-120° to 120°","cmc":"12″"}],"reference_zh":"内部程序 IW/KUM/21/01","regulatory_area_zh":"角度","search_zh":"光学角度水平仪 校准 — 角度 内部程序；使用光学分度头的直接法；在固定地点 (S) 角度 内部程序 使用光学分度头的直接法 在固定地点 (S) – 零位示值设定误差 – 分度值误差 – 全量程测量误差 内部程序 IW/KUM/21/01","technique_zh":"内部程序；使用光学分度头的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用光学分度头的直接法","在固定地点 (S)"],"test_object_zh":"光学角度水平仪","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"– chyba nastavení nulové indikace","range":"-120° to 120°","cmc":"0,2 dz. el."},{"name":"– chyba hodnoty dílku","range":"-120° to 120°","cmc":"4″"},{"name":"– chyba měření v celém rozsahu","range":"-120° to 120°","cmc":"12″"}],"reference_cs":"Vnitřní postup IW/KUM/21/01","regulatory_area_cs":"Úhel","search_cs":"Optické úhlové libely Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím optické dělicí hlavy; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím optické dělicí hlavy Ve stálé lokalitě (S) – chyba nastavení nulové indikace – chyba hodnoty dílku – chyba měření v celém rozsahu Vnitřní postup IW/KUM/21/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím optické dělicí hlavy; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím optické dělicí hlavy","Ve stálé lokalitě (S)"],"test_object_cs":"Optické úhlové libely"},{"_id":"690e1c134f77f55b56432477","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Płytki kątowe o matowych powierzchniach","test_object_en":"Angle gauge blocks with matt surfaces","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 30°","cmc":"31″"}],"parameters_en":[{"name":"","range":"0° to 30°","cmc":"31″"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using a microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem mikroskopu","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using a microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 30° CMC 31″\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/10/03","norm_bases":["IW/KUM/10/03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Płytki kątowe o matowych powierzchniach Wzorcowanie — Kąt\n0° do 30° CMC 31″\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem mikroskopu; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/10/03 Plytki katowe o matowych powierzchniach Wzorcowanie — Kat\n0° do 30° CMC 31″\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem mikroskopu; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/10/03","search_en":"Angle gauge blocks with matt surfaces Calibration — Angle Internal procedure; Indirect method using a microscope; At permanent location (S) Angle Internal procedure Indirect method using a microscope At permanent location (S) Internal procedure IW/KUM/10/03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":100,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/10/03","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° to 30°","cmc":"31″"}],"reference_de":"Internes Verfahren IW/KUM/10/03","regulatory_area_de":"Winkel","search_de":"Winkelendmaße mit matten Oberflächen Kalibrierung — Winkel Internes Verfahren; Indirektes Verfahren mit einem Mikroskop; Am festen Standort (S) Winkel Internes Verfahren Indirektes Verfahren mit einem Mikroskop Am festen Standort (S) Internes Verfahren IW/KUM/10/03","technique_de":"Internes Verfahren; Indirektes Verfahren mit einem Mikroskop; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit einem Mikroskop","Am festen Standort (S)"],"test_object_de":"Winkelendmaße mit matten Oberflächen","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° to 30°","cmc":"31″"}],"reference_zh":"内部程序 IW/KUM/10/03","regulatory_area_zh":"角度","search_zh":"无光泽表面角度块 校准 — 角度 内部程序；使用显微镜的间接法；在固定地点 (S) 角度 内部程序 使用显微镜的间接法 在固定地点 (S) 内部程序 IW/KUM/10/03","technique_zh":"内部程序；使用显微镜的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用显微镜的间接法","在固定地点 (S)"],"test_object_zh":"无光泽表面角度块","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° to 30°","cmc":"31″"}],"reference_cs":"Vnitřní postup IW/KUM/10/03","regulatory_area_cs":"Úhel","search_cs":"Úhlové měrky s matnými povrchy Kalibrace — Úhel Vnitřní postup; Nepřímá metoda s použitím mikroskopu; Ve stálé lokalitě (S) Úhel Vnitřní postup Nepřímá metoda s použitím mikroskopu Ve stálé lokalitě (S) Vnitřní postup IW/KUM/10/03","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím mikroskopu; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím mikroskopu","Ve stálé lokalitě (S)"],"test_object_cs":"Úhlové měrky s matnými povrchy"},{"_id":"8991d99035e05ac119da1ab0","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Poziomnice budowlane","test_object_en":"Builder's levels","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"– błąd ustawienia wskazania zerowego ampułki","range":"0 m do 2 m","cmc":"0,2 mm"}],"parameters_en":[{"name":"– vial zero indication setting error","range":"0 m to 2 m","cmc":"0,2 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem łoża pomiarowego CARL ZEISS JENA; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a CARL ZEISS JENA measuring bed; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem łoża pomiarowego CARL ZEISS JENA","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a CARL ZEISS JENA measuring bed","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n– błąd ustawienia wskazania zerowego ampułki 0 m do 2 m CMC 0,2 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem łoża pomiarowego CARL ZEISS JENA; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/11/02","norm_bases":["IW/KUM/11/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Poziomnice budowlane Wzorcowanie — Kąt\n– błąd ustawienia wskazania zerowego ampułki 0 m do 2 m CMC 0,2 mm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem łoża pomiarowego CARL ZEISS JENA; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/11/02 Poziomnice budowlane Wzorcowanie — Kat\n– blad ustawienia wskazania zerowego ampulki 0 m do 2 m CMC 0,2 mm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem loza pomiarowego CARL ZEISS JENA; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/11/02","search_en":"Builder's levels Calibration — Angle Internal procedure; Direct method using a CARL ZEISS JENA measuring bed; At permanent location (S) Angle Internal procedure Direct method using a CARL ZEISS JENA measuring bed At permanent location (S) – vial zero indication setting error Internal procedure IW/KUM/11/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":101,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/11/02","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"– Nullpunkteinstellfehler der Libelle","range":"0 m to 2 m","cmc":"0,2 mm"}],"reference_de":"Internes Verfahren IW/KUM/11/02","regulatory_area_de":"Winkel","search_de":"Wasserwaagen für das Bauwesen Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit einer Messbank CARL ZEISS JENA; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit einer Messbank CARL ZEISS JENA Am festen Standort (S) – Nullpunkteinstellfehler der Libelle Internes Verfahren IW/KUM/11/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einer Messbank CARL ZEISS JENA; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einer Messbank CARL ZEISS JENA","Am festen Standort (S)"],"test_object_de":"Wasserwaagen für das Bauwesen","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"– 水准泡零位示值设定误差","range":"0 m to 2 m","cmc":"0,2 mm"}],"reference_zh":"内部程序 IW/KUM/11/02","regulatory_area_zh":"角度","search_zh":"建筑水平尺 校准 — 角度 内部程序；使用CARL ZEISS JENA测量台的直接法；在固定地点 (S) 角度 内部程序 使用CARL ZEISS JENA测量台的直接法 在固定地点 (S) – 水准泡零位示值设定误差 内部程序 IW/KUM/11/02","technique_zh":"内部程序；使用CARL ZEISS JENA测量台的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用CARL ZEISS JENA测量台的直接法","在固定地点 (S)"],"test_object_zh":"建筑水平尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"– chyba nastavení nulové indikace libely","range":"0 m to 2 m","cmc":"0,2 mm"}],"reference_cs":"Vnitřní postup IW/KUM/11/02","regulatory_area_cs":"Úhel","search_cs":"Stavební vodováhy Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím měřicího lože CARL ZEISS JENA; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím měřicího lože CARL ZEISS JENA Ve stálé lokalitě (S) – chyba nastavení nulové indikace libely Vnitřní postup IW/KUM/11/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím měřicího lože CARL ZEISS JENA; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím měřicího lože CARL ZEISS JENA","Ve stálé lokalitě (S)"],"test_object_cs":"Stavební vodováhy"},{"_id":"a5d029dd9f94df46ec14e51e","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Poziomnice cyfrowe","test_object_en":"Digital levels","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"4 x 90°","cmc":"0,04°"}],"parameters_en":[{"name":"","range":"4 x 90°","cmc":"0,04°"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej CARL ZEISS JENA; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a CARL ZEISS JENA optical dividing head; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej CARL ZEISS JENA","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a CARL ZEISS JENA optical dividing head","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n4 x 90° CMC 0,04°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej CARL ZEISS JENA; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/11/02","norm_bases":["IW/KUM/11/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Poziomnice cyfrowe Wzorcowanie — Kąt\n4 x 90° CMC 0,04°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej CARL ZEISS JENA; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/11/02 Poziomnice cyfrowe Wzorcowanie — Kat\n4 x 90° CMC 0,04°\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem optycznej glowicy podzialowej CARL ZEISS JENA; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/11/02","search_en":"Digital levels Calibration — Angle Internal procedure; Direct method using a CARL ZEISS JENA optical dividing head; At permanent location (S) Angle Internal procedure Direct method using a CARL ZEISS JENA optical dividing head At permanent location (S) Internal procedure IW/KUM/11/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":102,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/11/02","methodology_de":"Kalibrierung — Winkel","reference_de":"Internes Verfahren IW/KUM/11/02","regulatory_area_de":"Winkel","search_de":"Digitale Wasserwaagen Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit einem optischen Teilkopf CARL ZEISS JENA; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit einem optischen Teilkopf CARL ZEISS JENA Am festen Standort (S) Internes Verfahren IW/KUM/11/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einem optischen Teilkopf CARL ZEISS JENA; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem optischen Teilkopf CARL ZEISS JENA","Am festen Standort (S)"],"test_object_de":"Digitale Wasserwaagen","methodology_zh":"校准 — 角度","reference_zh":"内部程序 IW/KUM/11/02","regulatory_area_zh":"角度","search_zh":"数显水平仪 校准 — 角度 内部程序；使用CARL ZEISS JENA光学分度头的直接法；在固定地点 (S) 角度 内部程序 使用CARL ZEISS JENA光学分度头的直接法 在固定地点 (S) 内部程序 IW/KUM/11/02","technique_zh":"内部程序；使用CARL ZEISS JENA光学分度头的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用CARL ZEISS JENA光学分度头的直接法","在固定地点 (S)"],"test_object_zh":"数显水平仪","methodology_cs":"Kalibrace — Úhel","reference_cs":"Vnitřní postup IW/KUM/11/02","regulatory_area_cs":"Úhel","search_cs":"Digitální libely Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím optické dělicí hlavy CARL ZEISS JENA; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím optické dělicí hlavy CARL ZEISS JENA Ve stálé lokalitě (S) Vnitřní postup IW/KUM/11/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím optické dělicí hlavy CARL ZEISS JENA; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím optické dělicí hlavy CARL ZEISS JENA","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální libely"},{"_id":"7259dd7cf1d7f1845a252c36","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Poziomnice koincydencyjne","test_object_en":"Coincidence levels","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"– błąd pomiaru w całym zakresie","range":"0 mm/m do 20 mm/m","cmc":"0,014 mm/m"},{"name":"– błąd ustawienia wskazania zerowego","range":"0 mm/m do 20 mm/m","cmc":"0,002 mm/m"}],"parameters_en":[{"name":"– measurement error over the full range","range":"0 mm/m to 20 mm/m","cmc":"0,014 mm/m"},{"name":"– zero indication setting error","range":"0 mm/m to 20 mm/m","cmc":"0,002 mm/m"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej CARL ZEISS JENA; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a CARL ZEISS JENA optical dividing head; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej CARL ZEISS JENA","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a CARL ZEISS JENA optical dividing head","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\nZakres:\n– błąd pomiaru w całym zakresie 0 mm/m do 20 mm/m CMC 0,014 mm/m\n– błąd ustawienia wskazania zerowego 0 mm/m do 20 mm/m CMC 0,002 mm/m\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej CARL ZEISS JENA; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/21/02","norm_bases":["IW/KUM/21/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Poziomnice koincydencyjne Wzorcowanie — Kąt\nZakres:\n– błąd pomiaru w całym zakresie 0 mm/m do 20 mm/m CMC 0,014 mm/m\n– błąd ustawienia wskazania zerowego 0 mm/m do 20 mm/m CMC 0,002 mm/m\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem optycznej głowicy podziałowej CARL ZEISS JENA; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/21/02 Poziomnice koincydencyjne Wzorcowanie — Kat\nZakres:\n– blad pomiaru w calym zakresie 0 mm/m do 20 mm/m CMC 0,014 mm/m\n– blad ustawienia wskazania zerowego 0 mm/m do 20 mm/m CMC 0,002 mm/m\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem optycznej glowicy podzialowej CARL ZEISS JENA; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/21/02","search_en":"Coincidence levels Calibration — Angle Internal procedure; Direct method using a CARL ZEISS JENA optical dividing head; At permanent location (S) Angle Internal procedure Direct method using a CARL ZEISS JENA optical dividing head At permanent location (S) – measurement error over the full range – zero indication setting error Internal procedure IW/KUM/21/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":103,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/21/02","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"– Messfehler im gesamten Bereich","range":"0 mm/m to 20 mm/m","cmc":"0,014 mm/m"},{"name":"– Nullpunkteinstellfehler","range":"0 mm/m to 20 mm/m","cmc":"0,002 mm/m"}],"reference_de":"Internes Verfahren IW/KUM/21/02","regulatory_area_de":"Winkel","search_de":"Koinzidenzlibellen Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit einem optischen Teilkopf CARL ZEISS JENA; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit einem optischen Teilkopf CARL ZEISS JENA Am festen Standort (S) – Messfehler im gesamten Bereich – Nullpunkteinstellfehler Internes Verfahren IW/KUM/21/02","technique_de":"Internes Verfahren; Direktes Verfahren mit einem optischen Teilkopf CARL ZEISS JENA; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einem optischen Teilkopf CARL ZEISS JENA","Am festen Standort (S)"],"test_object_de":"Koinzidenzlibellen","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"– 全量程测量误差","range":"0 mm/m to 20 mm/m","cmc":"0,014 mm/m"},{"name":"– 零位示值设定误差","range":"0 mm/m to 20 mm/m","cmc":"0,002 mm/m"}],"reference_zh":"内部程序 IW/KUM/21/02","regulatory_area_zh":"角度","search_zh":"合像水平仪 校准 — 角度 内部程序；使用CARL ZEISS JENA光学分度头的直接法；在固定地点 (S) 角度 内部程序 使用CARL ZEISS JENA光学分度头的直接法 在固定地点 (S) – 全量程测量误差 – 零位示值设定误差 内部程序 IW/KUM/21/02","technique_zh":"内部程序；使用CARL ZEISS JENA光学分度头的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用CARL ZEISS JENA光学分度头的直接法","在固定地点 (S)"],"test_object_zh":"合像水平仪","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"– chyba měření v celém rozsahu","range":"0 mm/m to 20 mm/m","cmc":"0,014 mm/m"},{"name":"– chyba nastavení nulové indikace","range":"0 mm/m to 20 mm/m","cmc":"0,002 mm/m"}],"reference_cs":"Vnitřní postup IW/KUM/21/02","regulatory_area_cs":"Úhel","search_cs":"Koincidenční libely Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím optické dělicí hlavy CARL ZEISS JENA; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím optické dělicí hlavy CARL ZEISS JENA Ve stálé lokalitě (S) – chyba měření v celém rozsahu – chyba nastavení nulové indikace Vnitřní postup IW/KUM/21/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím optické dělicí hlavy CARL ZEISS JENA; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím optické dělicí hlavy CARL ZEISS JENA","Ve stálé lokalitě (S)"],"test_object_cs":"Koincidenční libely"},{"_id":"fa9b79866b0d415983312fd6","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Poziomnice liniałowe","test_object_en":"Straightedge levels","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"– błąd ustawienia wskazania zerowego","range":"0 mm/m do 1 mm/m","cmc":"0,2 dz. el."},{"name":"– błąd wartości działki elementarnej","range":"0 mm/m do 1 mm/m","cmc":"0,019 mm/m"}],"parameters_en":[{"name":"– zero indication setting error","range":"0 mm/m to 1 mm/m","cmc":"0,2 dz. el."},{"name":"– scale interval value error","range":"0 mm/m to 1 mm/m","cmc":"0,019 mm/m"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem poziomnicy koincydencyjnej; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a coincidence level; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem poziomnicy koincydencyjnej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a coincidence level","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\nZakres:\n– błąd ustawienia wskazania zerowego 0 mm/m do 1 mm/m CMC 0,2 dz. el.\n– błąd wartości działki elementarnej 0 mm/m do 1 mm/m CMC 0,019 mm/m\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem poziomnicy koincydencyjnej; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/11/01","norm_bases":["IW/KUM/11/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Poziomnice liniałowe Wzorcowanie — Kąt\nZakres:\n– błąd ustawienia wskazania zerowego 0 mm/m do 1 mm/m CMC 0,2 dz. el.\n– błąd wartości działki elementarnej 0 mm/m do 1 mm/m CMC 0,019 mm/m\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem poziomnicy koincydencyjnej; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/11/01 Poziomnice linialowe Wzorcowanie — Kat\nZakres:\n– blad ustawienia wskazania zerowego 0 mm/m do 1 mm/m CMC 0,2 dz. el.\n– blad wartosci dzialki elementarnej 0 mm/m do 1 mm/m CMC 0,019 mm/m\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem poziomnicy koincydencyjnej; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/11/01","search_en":"Straightedge levels Calibration — Angle Internal procedure; Direct method using a coincidence level; At permanent location (S) Angle Internal procedure Direct method using a coincidence level At permanent location (S) – zero indication setting error – scale interval value error Internal procedure IW/KUM/11/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":104,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/11/01","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"– Nullpunkteinstellfehler","range":"0 mm/m to 1 mm/m","cmc":"0,2 dz. el."},{"name":"– Fehler des Skalenteilungswerts","range":"0 mm/m to 1 mm/m","cmc":"0,019 mm/m"}],"reference_de":"Internes Verfahren IW/KUM/11/01","regulatory_area_de":"Winkel","search_de":"Linealwasserwaagen Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit einer Koinzidenzlibelle; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit einer Koinzidenzlibelle Am festen Standort (S) – Nullpunkteinstellfehler – Fehler des Skalenteilungswerts Internes Verfahren IW/KUM/11/01","technique_de":"Internes Verfahren; Direktes Verfahren mit einer Koinzidenzlibelle; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit einer Koinzidenzlibelle","Am festen Standort (S)"],"test_object_de":"Linealwasserwaagen","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"– 零位示值设定误差","range":"0 mm/m to 1 mm/m","cmc":"0,2 dz. el."},{"name":"– 分度值误差","range":"0 mm/m to 1 mm/m","cmc":"0,019 mm/m"}],"reference_zh":"内部程序 IW/KUM/11/01","regulatory_area_zh":"角度","search_zh":"尺式水平仪 校准 — 角度 内部程序；使用合像水平仪的直接法；在固定地点 (S) 角度 内部程序 使用合像水平仪的直接法 在固定地点 (S) – 零位示值设定误差 – 分度值误差 内部程序 IW/KUM/11/01","technique_zh":"内部程序；使用合像水平仪的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用合像水平仪的直接法","在固定地点 (S)"],"test_object_zh":"尺式水平仪","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"– chyba nastavení nulové indikace","range":"0 mm/m to 1 mm/m","cmc":"0,2 dz. el."},{"name":"– chyba hodnoty dílku","range":"0 mm/m to 1 mm/m","cmc":"0,019 mm/m"}],"reference_cs":"Vnitřní postup IW/KUM/11/01","regulatory_area_cs":"Úhel","search_cs":"Pravítkové libely Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím koincidenční libely; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím koincidenční libely Ve stálé lokalitě (S) – chyba nastavení nulové indikace – chyba hodnoty dílku Vnitřní postup IW/KUM/11/01","technique_cs":"Vnitřní postup; Přímá metoda s použitím koincidenční libely; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koincidenční libely","Ve stálé lokalitě (S)"],"test_object_cs":"Pravítkové libely"},{"_id":"aa69958a179bdc592349c342","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Spoinomierze","test_object_en":"Weld gauges","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"– pomiary kąta ukosowania","range":"80° do 160°","cmc":"0,29°"}],"parameters_en":[{"name":"– bevel angle measurements","range":"80° to 160°","cmc":"0,29°"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n– pomiary kąta ukosowania 80° do 160° CMC 0,29°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/01/02","norm_bases":["IW/KUM/01/02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Spoinomierze Wzorcowanie — Kąt\n– pomiary kąta ukosowania 80° do 160° CMC 0,29°\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/01/02 Spoinomierze Wzorcowanie — Kat\n– pomiary kata ukosowania 80° do 160° CMC 0,29°\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/01/02","search_en":"Weld gauges Calibration — Angle Internal procedure; Direct method using angle gauge blocks; At permanent location (S) Angle Internal procedure Direct method using angle gauge blocks At permanent location (S) – bevel angle measurements Internal procedure IW/KUM/01/02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":105,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/01/02","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"– Messungen des Fugenflankenwinkels","range":"80° to 160°","cmc":"0,29°"}],"reference_de":"Internes Verfahren IW/KUM/01/02","regulatory_area_de":"Winkel","search_de":"Schweißnahtlehren Kalibrierung — Winkel Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren Direktes Verfahren mit Winkelendmaßen Am festen Standort (S) – Messungen des Fugenflankenwinkels Internes Verfahren IW/KUM/01/02","technique_de":"Internes Verfahren; Direktes Verfahren mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Schweißnahtlehren","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"– 坡口角度测量","range":"80° to 160°","cmc":"0,29°"}],"reference_zh":"内部程序 IW/KUM/01/02","regulatory_area_zh":"角度","search_zh":"焊缝量规 校准 — 角度 内部程序；使用角度量块的直接法；在固定地点 (S) 角度 内部程序 使用角度量块的直接法 在固定地点 (S) – 坡口角度测量 内部程序 IW/KUM/01/02","technique_zh":"内部程序；使用角度量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用角度量块的直接法","在固定地点 (S)"],"test_object_zh":"焊缝量规","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"– měření úhlu úkosu","range":"80° to 160°","cmc":"0,29°"}],"reference_cs":"Vnitřní postup IW/KUM/01/02","regulatory_area_cs":"Úhel","search_cs":"Svarové měrky Kalibrace — Úhel Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup Přímá metoda s použitím úhlových koncových měrek Ve stálé lokalitě (S) – měření úhlu úkosu Vnitřní postup IW/KUM/01/02","technique_cs":"Vnitřní postup; Přímá metoda s použitím úhlových koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím úhlových koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Svarové měrky"},{"_id":"f7f746161b675fadfd2afaaa","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Liniały krawędziowe","test_object_en":"Knife-edge straightedges","methodology":"Wzorcowanie — Geometria powierzchni","methodology_en":"Calibration — Surface geometry","parameters":[{"name":"","range":"0 mm do 100 mm","cmc":"0,7 µm"},{"name":"","range":"100 mm do 400 mm","cmc":"2,3 µm"},{"name":"","range":"400 mm do 700 mm","cmc":"3,9 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,7 µm"},{"name":"","range":"100 mm to 400 mm","cmc":"2,3 µm"},{"name":"","range":"400 mm to 700 mm","cmc":"3,9 µm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia z zastosowaniem płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Geometria powierzchni\nZakres:\n0 mm do 100 mm CMC 0,7 µm\n100 mm do 400 mm CMC 2,3 µm\n400 mm do 700 mm CMC 3,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/17/03","norm_bases":["IW/KUM/17/03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Geometria powierzchni","regulatory_area_en":"Surface geometry","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Liniały krawędziowe Wzorcowanie — Geometria powierzchni\nZakres:\n0 mm do 100 mm CMC 0,7 µm\n100 mm do 400 mm CMC 2,3 µm\n400 mm do 700 mm CMC 3,9 µm\nProcedura wewnętrzna; Metoda bezpośrednia z zastosowaniem płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/17/03 Linialy krawedziowe Wzorcowanie — Geometria powierzchni\nZakres:\n0 mm do 100 mm CMC 0,7 µm\n100 mm do 400 mm CMC 2,3 µm\n400 mm do 700 mm CMC 3,9 µm\nProcedura wewnetrzna; Metoda bezposrednia z zastosowaniem plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/17/03","search_en":"Knife-edge straightedges Calibration — Surface geometry Internal procedure; Direct method using gauge blocks; At permanent location (S) Surface geometry Internal procedure Direct method using gauge blocks At permanent location (S) Internal procedure IW/KUM/17/03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":106,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/17/03","methodology_de":"Kalibrierung — Oberflächengeometrie","parameters_de":[{"name":"","range":"0 mm to 100 mm","cmc":"0,7 µm"},{"name":"","range":"100 mm to 400 mm","cmc":"2,3 µm"},{"name":"","range":"400 mm to 700 mm","cmc":"3,9 µm"}],"reference_de":"Internes Verfahren IW/KUM/17/03","regulatory_area_de":"Oberflächengeometrie","search_de":"Haarlineale Kalibrierung — Oberflächengeometrie Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S) Oberflächengeometrie Internes Verfahren Direktes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW/KUM/17/03","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Haarlineale","methodology_zh":"校准 — 表面几何量","parameters_zh":[{"name":"","range":"0 mm to 100 mm","cmc":"0,7 µm"},{"name":"","range":"100 mm to 400 mm","cmc":"2,3 µm"},{"name":"","range":"400 mm to 700 mm","cmc":"3,9 µm"}],"reference_zh":"内部程序 IW/KUM/17/03","regulatory_area_zh":"表面几何量","search_zh":"刀口尺 校准 — 表面几何量 内部程序；使用量块的直接法；在固定地点 (S) 表面几何量 内部程序 使用量块的直接法 在固定地点 (S) 内部程序 IW/KUM/17/03","technique_zh":"内部程序；使用量块的直接法；在固定地点 (S)","techniques_zh":["内部程序","使用量块的直接法","在固定地点 (S)"],"test_object_zh":"刀口尺","methodology_cs":"Kalibrace — Geometrie povrchu","parameters_cs":[{"name":"","range":"0 mm to 100 mm","cmc":"0,7 µm"},{"name":"","range":"100 mm to 400 mm","cmc":"2,3 µm"},{"name":"","range":"400 mm to 700 mm","cmc":"3,9 µm"}],"reference_cs":"Vnitřní postup IW/KUM/17/03","regulatory_area_cs":"Geometrie povrchu","search_cs":"Nožová pravítka Kalibrace — Geometrie povrchu Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S) Geometrie povrchu Vnitřní postup Přímá metoda s použitím koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW/KUM/17/03","technique_cs":"Vnitřní postup; Přímá metoda s použitím koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda s použitím koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Nožová pravítka"},{"_id":"a69666693744c51dbe470cf6","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Płaskie płytki interferencyjne","test_object_en":"Optical flats","methodology":"Wzorcowanie — Geometria powierzchni","methodology_en":"Calibration — Surface geometry","parameters":[{"name":"średnica","range":"0 mm do 100 mm","cmc":"0,04 µm"}],"parameters_en":[{"name":"diameter","range":"0 mm to 100 mm","cmc":"0,04 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem płytek interferencyjnych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using optical flats; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem płytek interferencyjnych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using optical flats","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Geometria powierzchni\nśrednica 0 mm do 100 mm CMC 0,04 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem płytek interferencyjnych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/08/01","norm_bases":["IW/KUM/08/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Geometria powierzchni","regulatory_area_en":"Surface geometry","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Płaskie płytki interferencyjne Wzorcowanie — Geometria powierzchni\nśrednica 0 mm do 100 mm CMC 0,04 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem płytek interferencyjnych; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/08/01 Plaskie plytki interferencyjne Wzorcowanie — Geometria powierzchni\nsrednica 0 mm do 100 mm CMC 0,04 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem plytek interferencyjnych; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/08/01","search_en":"Optical flats Calibration — Surface geometry Internal procedure; Indirect method using optical flats; At permanent location (S) Surface geometry Internal procedure Indirect method using optical flats At permanent location (S) diameter Internal procedure IW/KUM/08/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":107,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/08/01","methodology_de":"Kalibrierung — Oberflächengeometrie","parameters_de":[{"name":"Durchmesser","range":"0 mm to 100 mm","cmc":"0,04 µm"}],"reference_de":"Internes Verfahren IW/KUM/08/01","regulatory_area_de":"Oberflächengeometrie","search_de":"Planglasplatten Kalibrierung — Oberflächengeometrie Internes Verfahren; Indirektes Verfahren mit Planglasplatten; Am festen Standort (S) Oberflächengeometrie Internes Verfahren Indirektes Verfahren mit Planglasplatten Am festen Standort (S) Durchmesser Internes Verfahren IW/KUM/08/01","technique_de":"Internes Verfahren; Indirektes Verfahren mit Planglasplatten; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit Planglasplatten","Am festen Standort (S)"],"test_object_de":"Planglasplatten","methodology_zh":"校准 — 表面几何量","parameters_zh":[{"name":"直径","range":"0 mm to 100 mm","cmc":"0,04 µm"}],"reference_zh":"内部程序 IW/KUM/08/01","regulatory_area_zh":"表面几何量","search_zh":"平面平晶 校准 — 表面几何量 内部程序；使用平晶的间接法；在固定地点 (S) 表面几何量 内部程序 使用平晶的间接法 在固定地点 (S) 直径 内部程序 IW/KUM/08/01","technique_zh":"内部程序；使用平晶的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用平晶的间接法","在固定地点 (S)"],"test_object_zh":"平面平晶","methodology_cs":"Kalibrace — Geometrie povrchu","parameters_cs":[{"name":"průměr","range":"0 mm to 100 mm","cmc":"0,04 µm"}],"reference_cs":"Vnitřní postup IW/KUM/08/01","regulatory_area_cs":"Geometrie povrchu","search_cs":"Rovinné interferenční destičky Kalibrace — Geometrie povrchu Vnitřní postup; Nepřímá metoda s použitím interferenčních destiček; Ve stálé lokalitě (S) Geometrie povrchu Vnitřní postup Nepřímá metoda s použitím interferenčních destiček Ve stálé lokalitě (S) průměr Vnitřní postup IW/KUM/08/01","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím interferenčních destiček; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím interferenčních destiček","Ve stálé lokalitě (S)"],"test_object_cs":"Rovinné interferenční destičky"},{"_id":"7195b90ad53b82c3e24f4c61","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Płaskorównoległe płytki interferencyjne","test_object_en":"Plane-parallel optical flats","methodology":"Wzorcowanie — Geometria powierzchni","methodology_en":"Calibration — Surface geometry","parameters":[{"name":"długość płytek; – odchyłka płaskości powierzchni","range":"12,00 mm do 80,00 mm","cmc":"0,06 µm"},{"name":"długość płytek; – odchyłka równoległości powierzchni","range":"12,00 mm do 80,00 mm","cmc":"0,16 µm"}],"parameters_en":[{"name":"flat length; – surface flatness deviation","range":"12,00 mm to 80,00 mm","cmc":"0,06 µm"},{"name":"flat length; – surface parallelism deviation","range":"12,00 mm to 80,00 mm","cmc":"0,16 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem płytek interferencyjnych oraz czujnika MOP 02/20; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method using optical flats and a MOP 02/20 probe; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem płytek interferencyjnych oraz czujnika MOP 02/20","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method using optical flats and a MOP 02/20 probe","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Geometria powierzchni\nZakres:\ndługość płytek; – odchyłka płaskości powierzchni 12,00 mm do 80,00 mm CMC 0,06 µm\ndługość płytek; – odchyłka równoległości powierzchni 12,00 mm do 80,00 mm CMC 0,16 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem płytek interferencyjnych oraz czujnika MOP 02/20; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW/KUM/08/01","norm_bases":["IW/KUM/08/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Geometria powierzchni","regulatory_area_en":"Surface geometry","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Płaskorównoległe płytki interferencyjne Wzorcowanie — Geometria powierzchni\nZakres:\ndługość płytek; – odchyłka płaskości powierzchni 12,00 mm do 80,00 mm CMC 0,06 µm\ndługość płytek; – odchyłka równoległości powierzchni 12,00 mm do 80,00 mm CMC 0,16 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem płytek interferencyjnych oraz czujnika MOP 02/20; W stałej lokalizacji (S) Procedura wewnętrzna IW/KUM/08/01 Plaskorownolegle plytki interferencyjne Wzorcowanie — Geometria powierzchni\nZakres:\ndlugosc plytek; – odchylka plaskosci powierzchni 12,00 mm do 80,00 mm CMC 0,06 µm\ndlugosc plytek; – odchylka rownoleglosci powierzchni 12,00 mm do 80,00 mm CMC 0,16 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem plytek interferencyjnych oraz czujnika MOP 02/20; W stalej lokalizacji (S) Procedura wewnetrzna IW/KUM/08/01","search_en":"Plane-parallel optical flats Calibration — Surface geometry Internal procedure; Indirect method using optical flats and a MOP 02/20 probe; At permanent location (S) Surface geometry Internal procedure Indirect method using optical flats and a MOP 02/20 probe At permanent location (S) flat length; – surface flatness deviation flat length; – surface parallelism deviation Internal procedure IW/KUM/08/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":108,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/08/01","methodology_de":"Kalibrierung — Oberflächengeometrie","parameters_de":[{"name":"Plattenlänge; – Ebenheitsabweichung der Fläche","range":"12,00 mm to 80,00 mm","cmc":"0,06 µm"},{"name":"Plattenlänge; – Parallelitätsabweichung der Flächen","range":"12,00 mm to 80,00 mm","cmc":"0,16 µm"}],"reference_de":"Internes Verfahren IW/KUM/08/01","regulatory_area_de":"Oberflächengeometrie","search_de":"Planparallele Interferenzplatten Kalibrierung — Oberflächengeometrie Internes Verfahren; Indirektes Verfahren mit Planglasplatten und einem Messtaster MOP 02/20; Am festen Standort (S) Oberflächengeometrie Internes Verfahren Indirektes Verfahren mit Planglasplatten und einem Messtaster MOP 02/20 Am festen Standort (S) Plattenlänge; – Ebenheitsabweichung der Fläche Plattenlänge; – Parallelitätsabweichung der Flächen Internes Verfahren IW/KUM/08/01","technique_de":"Internes Verfahren; Indirektes Verfahren mit Planglasplatten und einem Messtaster MOP 02/20; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit Planglasplatten und einem Messtaster MOP 02/20","Am festen Standort (S)"],"test_object_de":"Planparallele Interferenzplatten","methodology_zh":"校准 — 表面几何量","parameters_zh":[{"name":"平晶长度；– 表面平面度偏差","range":"12,00 mm to 80,00 mm","cmc":"0,06 µm"},{"name":"平晶长度；– 表面平行度偏差","range":"12,00 mm to 80,00 mm","cmc":"0,16 µm"}],"reference_zh":"内部程序 IW/KUM/08/01","regulatory_area_zh":"表面几何量","search_zh":"平行平晶干涉板 校准 — 表面几何量 内部程序；使用平晶和MOP 02/20测头的间接法；在固定地点 (S) 表面几何量 内部程序 使用平晶和MOP 02/20测头的间接法 在固定地点 (S) 平晶长度；– 表面平面度偏差 平晶长度；– 表面平行度偏差 内部程序 IW/KUM/08/01","technique_zh":"内部程序；使用平晶和MOP 02/20测头的间接法；在固定地点 (S)","techniques_zh":["内部程序","使用平晶和MOP 02/20测头的间接法","在固定地点 (S)"],"test_object_zh":"平行平晶干涉板","methodology_cs":"Kalibrace — Geometrie povrchu","parameters_cs":[{"name":"délka destiček; – odchylka rovinnosti povrchu","range":"12,00 mm to 80,00 mm","cmc":"0,06 µm"},{"name":"délka destiček; – odchylka rovnoběžnosti povrchů","range":"12,00 mm to 80,00 mm","cmc":"0,16 µm"}],"reference_cs":"Vnitřní postup IW/KUM/08/01","regulatory_area_cs":"Geometrie povrchu","search_cs":"Planparalelní interferenční destičky Kalibrace — Geometrie povrchu Vnitřní postup; Nepřímá metoda s použitím interferenčních destiček a snímače MOP 02/20; Ve stálé lokalitě (S) Geometrie povrchu Vnitřní postup Nepřímá metoda s použitím interferenčních destiček a snímače MOP 02/20 Ve stálé lokalitě (S) délka destiček; – odchylka rovinnosti povrchu délka destiček; – odchylka rovnoběžnosti povrchů Vnitřní postup IW/KUM/08/01","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím interferenčních destiček a snímače MOP 02/20; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím interferenčních destiček a snímače MOP 02/20","Ve stálé lokalitě (S)"],"test_object_cs":"Planparalelní interferenční destičky"},{"_id":"78fe83c34111fe5a0ae3883b","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Płyty pomiarowe","test_object_en":"Surface plates","methodology":"Wzorcowanie — Geometria powierzchni","methodology_en":"Calibration — Surface geometry","parameters":[{"name":"długość dłuższego boku","range":"250 mm","cmc":"1,1 µm"},{"name":"długość dłuższego boku","range":"400 mm","cmc":"1,3 µm"},{"name":"długość dłuższego boku","range":"630 mm","cmc":"1,8 µm"},{"name":"długość dłuższego boku","range":"800 mm","cmc":"2,0 µm"},{"name":"długość dłuższego boku","range":"1000 mm","cmc":"2,2 µm"},{"name":"długość dłuższego boku","range":"1200 mm","cmc":"2,5 µm"},{"name":"długość dłuższego boku","range":"1600 mm","cmc":"2,9 µm"},{"name":"długość dłuższego boku","range":"2000 mm","cmc":"3,2 µm"},{"name":"długość dłuższego boku","range":"2500 mm","cmc":"3,6 µm"}],"parameters_en":[{"name":"longer side length","range":"250 mm","cmc":"1,1 µm"},{"name":"longer side length","range":"400 mm","cmc":"1,3 µm"},{"name":"longer side length","range":"630 mm","cmc":"1,8 µm"},{"name":"longer side length","range":"800 mm","cmc":"2,0 µm"},{"name":"longer side length","range":"1000 mm","cmc":"2,2 µm"},{"name":"longer side length","range":"1200 mm","cmc":"2,5 µm"},{"name":"longer side length","range":"1600 mm","cmc":"2,9 µm"},{"name":"longer side length","range":"2000 mm","cmc":"3,2 µm"},{"name":"longer side length","range":"2500 mm","cmc":"3,6 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem poziomnic różnicowych Talyvel 6 Taylor-Hobson; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Indirect method using Talyvel 6 Taylor-Hobson differential levels; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem poziomnic różnicowych Talyvel 6 Taylor-Hobson","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Indirect method using Talyvel 6 Taylor-Hobson differential levels","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Geometria powierzchni\nZakres:\ndługość dłuższego boku 250 mm CMC 1,1 µm\ndługość dłuższego boku 400 mm CMC 1,3 µm\ndługość dłuższego boku 630 mm CMC 1,8 µm\ndługość dłuższego boku 800 mm CMC 2,0 µm\ndługość dłuższego boku 1000 mm CMC 2,2 µm\ndługość dłuższego boku 1200 mm CMC 2,5 µm\ndługość dłuższego boku 1600 mm CMC 2,9 µm\ndługość dłuższego boku 2000 mm CMC 3,2 µm\ndługość dłuższego boku 2500 mm CMC 3,6 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem poziomnic różnicowych Talyvel 6 Taylor-Hobson; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna IW/KUM/20/01 oparta na PN-ISO 8512-1:1998 PN-ISO 8512-2:1999","norm_bases":["IW/KUM/20/01","PN-ISO 8512-1:1998","PN-ISO 8512-2:1999"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Geometria powierzchni","regulatory_area_en":"Surface geometry","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Płyty pomiarowe Wzorcowanie — Geometria powierzchni\nZakres:\ndługość dłuższego boku 250 mm CMC 1,1 µm\ndługość dłuższego boku 400 mm CMC 1,3 µm\ndługość dłuższego boku 630 mm CMC 1,8 µm\ndługość dłuższego boku 800 mm CMC 2,0 µm\ndługość dłuższego boku 1000 mm CMC 2,2 µm\ndługość dłuższego boku 1200 mm CMC 2,5 µm\ndługość dłuższego boku 1600 mm CMC 2,9 µm\ndługość dłuższego boku 2000 mm CMC 3,2 µm\ndługość dłuższego boku 2500 mm CMC 3,6 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem poziomnic różnicowych Talyvel 6 Taylor-Hobson; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna IW/KUM/20/01 oparta na PN-ISO 8512-1:1998 PN-ISO 8512-2:1999 Plyty pomiarowe Wzorcowanie — Geometria powierzchni\nZakres:\ndlugosc dluzszego boku 250 mm CMC 1,1 µm\ndlugosc dluzszego boku 400 mm CMC 1,3 µm\ndlugosc dluzszego boku 630 mm CMC 1,8 µm\ndlugosc dluzszego boku 800 mm CMC 2,0 µm\ndlugosc dluzszego boku 1000 mm CMC 2,2 µm\ndlugosc dluzszego boku 1200 mm CMC 2,5 µm\ndlugosc dluzszego boku 1600 mm CMC 2,9 µm\ndlugosc dluzszego boku 2000 mm CMC 3,2 µm\ndlugosc dluzszego boku 2500 mm CMC 3,6 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem poziomnic roznicowych Talyvel 6 Taylor-Hobson; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna IW/KUM/20/01 oparta na PN-ISO 8512-1:1998 PN-ISO 8512-2:1999","search_en":"Surface plates Calibration — Surface geometry Internal procedure; Indirect method using Talyvel 6 Taylor-Hobson differential levels; At permanent location (S) and outside of it (P) Surface geometry Internal procedure Indirect method using Talyvel 6 Taylor-Hobson differential levels At permanent location (S) and outside of it (P) longer side length longer side length longer side length longer side length longer side length longer side length longer side length longer side length longer side length Internal procedure IW/KUM/20/01 based on PN-ISO 8512-1:1998 PN-ISO 8512-2:1999","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":109,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/20/01 based on PN-ISO 8512-1:1998 PN-ISO 8512-2:1999","methodology_de":"Kalibrierung — Oberflächengeometrie","parameters_de":[{"name":"Länge der längeren Seite","range":"250 mm","cmc":"1,1 µm"},{"name":"Länge der längeren Seite","range":"400 mm","cmc":"1,3 µm"},{"name":"Länge der längeren Seite","range":"630 mm","cmc":"1,8 µm"},{"name":"Länge der längeren Seite","range":"800 mm","cmc":"2,0 µm"},{"name":"Länge der längeren Seite","range":"1000 mm","cmc":"2,2 µm"},{"name":"Länge der längeren Seite","range":"1200 mm","cmc":"2,5 µm"},{"name":"Länge der längeren Seite","range":"1600 mm","cmc":"2,9 µm"},{"name":"Länge der längeren Seite","range":"2000 mm","cmc":"3,2 µm"},{"name":"Länge der längeren Seite","range":"2500 mm","cmc":"3,6 µm"}],"reference_de":"Internes Verfahren IW/KUM/20/01 auf Grundlage von PN-ISO 8512-1:1998 PN-ISO 8512-2:1999","regulatory_area_de":"Oberflächengeometrie","search_de":"Messplatten Kalibrierung — Oberflächengeometrie Internes Verfahren; Indirektes Verfahren mit Differenzlibellen Talyvel 6 Taylor-Hobson; Am festen Standort (S) und außerhalb (P) Oberflächengeometrie Internes Verfahren Indirektes Verfahren mit Differenzlibellen Talyvel 6 Taylor-Hobson Am festen Standort (S) und außerhalb (P) Länge der längeren Seite Länge der längeren Seite Länge der längeren Seite Länge der längeren Seite Länge der längeren Seite Länge der längeren Seite Länge der längeren Seite Länge der längeren Seite Länge der längeren Seite Internes Verfahren IW/KUM/20/01 auf Grundlage von PN-ISO 8512-1:1998 PN-ISO 8512-2:1999","technique_de":"Internes Verfahren; Indirektes Verfahren mit Differenzlibellen Talyvel 6 Taylor-Hobson; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit Differenzlibellen Talyvel 6 Taylor-Hobson","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Messplatten","methodology_zh":"校准 — 表面几何量","parameters_zh":[{"name":"长边长度","range":"250 mm","cmc":"1,1 µm"},{"name":"长边长度","range":"400 mm","cmc":"1,3 µm"},{"name":"长边长度","range":"630 mm","cmc":"1,8 µm"},{"name":"长边长度","range":"800 mm","cmc":"2,0 µm"},{"name":"长边长度","range":"1000 mm","cmc":"2,2 µm"},{"name":"长边长度","range":"1200 mm","cmc":"2,5 µm"},{"name":"长边长度","range":"1600 mm","cmc":"2,9 µm"},{"name":"长边长度","range":"2000 mm","cmc":"3,2 µm"},{"name":"长边长度","range":"2500 mm","cmc":"3,6 µm"}],"reference_zh":"内部程序 IW/KUM/20/01 依据PN-ISO 8512-1:1998 PN-ISO 8512-2:1999","regulatory_area_zh":"表面几何量","search_zh":"测量平板 校准 — 表面几何量 内部程序；使用Talyvel 6 Taylor-Hobson差动水平仪的间接法；在固定地点 (S) 及固定地点以外 (P) 表面几何量 内部程序 使用Talyvel 6 Taylor-Hobson差动水平仪的间接法 在固定地点 (S) 及固定地点以外 (P) 长边长度 长边长度 长边长度 长边长度 长边长度 长边长度 长边长度 长边长度 长边长度 内部程序 IW/KUM/20/01 依据PN-ISO 8512-1:1998 PN-ISO 8512-2:1999","technique_zh":"内部程序；使用Talyvel 6 Taylor-Hobson差动水平仪的间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","使用Talyvel 6 Taylor-Hobson差动水平仪的间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"测量平板","methodology_cs":"Kalibrace — Geometrie povrchu","parameters_cs":[{"name":"délka delší strany","range":"250 mm","cmc":"1,1 µm"},{"name":"délka delší strany","range":"400 mm","cmc":"1,3 µm"},{"name":"délka delší strany","range":"630 mm","cmc":"1,8 µm"},{"name":"délka delší strany","range":"800 mm","cmc":"2,0 µm"},{"name":"délka delší strany","range":"1000 mm","cmc":"2,2 µm"},{"name":"délka delší strany","range":"1200 mm","cmc":"2,5 µm"},{"name":"délka delší strany","range":"1600 mm","cmc":"2,9 µm"},{"name":"délka delší strany","range":"2000 mm","cmc":"3,2 µm"},{"name":"délka delší strany","range":"2500 mm","cmc":"3,6 µm"}],"reference_cs":"Vnitřní postup IW/KUM/20/01 na základě PN-ISO 8512-1:1998 PN-ISO 8512-2:1999","regulatory_area_cs":"Geometrie povrchu","search_cs":"Příměrné desky Kalibrace — Geometrie povrchu Vnitřní postup; Nepřímá metoda s použitím diferenčních libel Talyvel 6 Taylor-Hobson; V trvalé lokalitě (S) i mimo ni (P) Geometrie povrchu Vnitřní postup Nepřímá metoda s použitím diferenčních libel Talyvel 6 Taylor-Hobson V trvalé lokalitě (S) i mimo ni (P) délka delší strany délka delší strany délka delší strany délka delší strany délka delší strany délka delší strany délka delší strany délka delší strany délka delší strany Vnitřní postup IW/KUM/20/01 na základě PN-ISO 8512-1:1998 PN-ISO 8512-2:1999","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím diferenčních libel Talyvel 6 Taylor-Hobson; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím diferenčních libel Talyvel 6 Taylor-Hobson","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Příměrné desky"},{"_id":"cc5e73654bbc2e94470b8381","lab_id":"6afa3b9c8989a133b76445cb","country":"PL","accr_number":"AP 162","accr_body":"PCA","test_object":"Liniały powierzchniowe","test_object_en":"Surface straightedges","methodology":"Wzorcowanie — Geometria powierzchni","methodology_en":"Calibration — Surface geometry","parameters":[{"name":"długość liniału","range":"250 mm","cmc":"1,0 µm"},{"name":"długość liniału","range":"500 mm","cmc":"1,5 µm"},{"name":"długość liniału","range":"1000 mm","cmc":"2,2 µm"},{"name":"długość liniału","range":"1500 mm","cmc":"2,8 µm"},{"name":"długość liniału","range":"2000 mm","cmc":"3,2 µm"},{"name":"długość liniału","range":"2500 mm","cmc":"3,6 µm"},{"name":"długość liniału","range":"3000 mm","cmc":"4,0 µm"},{"name":"długość liniału","range":"4000 mm","cmc":"4,6 µm"},{"name":"długość liniału","range":"5000 mm","cmc":"5,2 µm"}],"parameters_en":[{"name":"straightedge length","range":"250 mm","cmc":"1,0 µm"},{"name":"straightedge length","range":"500 mm","cmc":"1,5 µm"},{"name":"straightedge length","range":"1000 mm","cmc":"2,2 µm"},{"name":"straightedge length","range":"1500 mm","cmc":"2,8 µm"},{"name":"straightedge length","range":"2000 mm","cmc":"3,2 µm"},{"name":"straightedge length","range":"2500 mm","cmc":"3,6 µm"},{"name":"straightedge length","range":"3000 mm","cmc":"4,0 µm"},{"name":"straightedge length","range":"4000 mm","cmc":"4,6 µm"},{"name":"straightedge length","range":"5000 mm","cmc":"5,2 µm"}],"technique":"Procedura wewnętrzna; Metoda pośrednia z zastosowaniem poziomnic różnicowych Talyvel 6 Taylor-Hobson; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Indirect method using Talyvel 6 Taylor-Hobson differential levels; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia z zastosowaniem poziomnic różnicowych Talyvel 6 Taylor-Hobson","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Indirect method using Talyvel 6 Taylor-Hobson differential levels","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Geometria powierzchni\nZakres:\ndługość liniału 250 mm CMC 1,0 µm\ndługość liniału 500 mm CMC 1,5 µm\ndługość liniału 1000 mm CMC 2,2 µm\ndługość liniału 1500 mm CMC 2,8 µm\ndługość liniału 2000 mm CMC 3,2 µm\ndługość liniału 2500 mm CMC 3,6 µm\ndługość liniału 3000 mm CMC 4,0 µm\ndługość liniału 4000 mm CMC 4,6 µm\ndługość liniału 5000 mm CMC 5,2 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem poziomnic różnicowych Talyvel 6 Taylor-Hobson; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna IW/KUM/20/01","norm_bases":["IW/KUM/20/01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Geometria powierzchni","regulatory_area_en":"Surface geometry","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Liniały powierzchniowe Wzorcowanie — Geometria powierzchni\nZakres:\ndługość liniału 250 mm CMC 1,0 µm\ndługość liniału 500 mm CMC 1,5 µm\ndługość liniału 1000 mm CMC 2,2 µm\ndługość liniału 1500 mm CMC 2,8 µm\ndługość liniału 2000 mm CMC 3,2 µm\ndługość liniału 2500 mm CMC 3,6 µm\ndługość liniału 3000 mm CMC 4,0 µm\ndługość liniału 4000 mm CMC 4,6 µm\ndługość liniału 5000 mm CMC 5,2 µm\nProcedura wewnętrzna; Metoda pośrednia z zastosowaniem poziomnic różnicowych Talyvel 6 Taylor-Hobson; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna IW/KUM/20/01 Linialy powierzchniowe Wzorcowanie — Geometria powierzchni\nZakres:\ndlugosc linialu 250 mm CMC 1,0 µm\ndlugosc linialu 500 mm CMC 1,5 µm\ndlugosc linialu 1000 mm CMC 2,2 µm\ndlugosc linialu 1500 mm CMC 2,8 µm\ndlugosc linialu 2000 mm CMC 3,2 µm\ndlugosc linialu 2500 mm CMC 3,6 µm\ndlugosc linialu 3000 mm CMC 4,0 µm\ndlugosc linialu 4000 mm CMC 4,6 µm\ndlugosc linialu 5000 mm CMC 5,2 µm\nProcedura wewnetrzna; Metoda posrednia z zastosowaniem poziomnic roznicowych Talyvel 6 Taylor-Hobson; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna IW/KUM/20/01","search_en":"Surface straightedges Calibration — Surface geometry Internal procedure; Indirect method using Talyvel 6 Taylor-Hobson differential levels; At permanent location (S) and outside of it (P) Surface geometry Internal procedure Indirect method using Talyvel 6 Taylor-Hobson differential levels At permanent location (S) and outside of it (P) straightedge length straightedge length straightedge length straightedge length straightedge length straightedge length straightedge length straightedge length straightedge length Internal procedure IW/KUM/20/01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":110,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW/KUM/20/01","methodology_de":"Kalibrierung — Oberflächengeometrie","parameters_de":[{"name":"Lineallänge","range":"250 mm","cmc":"1,0 µm"},{"name":"Lineallänge","range":"500 mm","cmc":"1,5 µm"},{"name":"Lineallänge","range":"1000 mm","cmc":"2,2 µm"},{"name":"Lineallänge","range":"1500 mm","cmc":"2,8 µm"},{"name":"Lineallänge","range":"2000 mm","cmc":"3,2 µm"},{"name":"Lineallänge","range":"2500 mm","cmc":"3,6 µm"},{"name":"Lineallänge","range":"3000 mm","cmc":"4,0 µm"},{"name":"Lineallänge","range":"4000 mm","cmc":"4,6 µm"},{"name":"Lineallänge","range":"5000 mm","cmc":"5,2 µm"}],"reference_de":"Internes Verfahren IW/KUM/20/01","regulatory_area_de":"Oberflächengeometrie","search_de":"Haarlineale Kalibrierung — Oberflächengeometrie Internes Verfahren; Indirektes Verfahren mit Differenzlibellen Talyvel 6 Taylor-Hobson; Am festen Standort (S) und außerhalb (P) Oberflächengeometrie Internes Verfahren Indirektes Verfahren mit Differenzlibellen Talyvel 6 Taylor-Hobson Am festen Standort (S) und außerhalb (P) Lineallänge Lineallänge Lineallänge Lineallänge Lineallänge Lineallänge Lineallänge Lineallänge Lineallänge Internes Verfahren IW/KUM/20/01","technique_de":"Internes Verfahren; Indirektes Verfahren mit Differenzlibellen Talyvel 6 Taylor-Hobson; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Indirektes Verfahren mit Differenzlibellen Talyvel 6 Taylor-Hobson","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Haarlineale","methodology_zh":"校准 — 表面几何量","parameters_zh":[{"name":"平尺长度","range":"250 mm","cmc":"1,0 µm"},{"name":"平尺长度","range":"500 mm","cmc":"1,5 µm"},{"name":"平尺长度","range":"1000 mm","cmc":"2,2 µm"},{"name":"平尺长度","range":"1500 mm","cmc":"2,8 µm"},{"name":"平尺长度","range":"2000 mm","cmc":"3,2 µm"},{"name":"平尺长度","range":"2500 mm","cmc":"3,6 µm"},{"name":"平尺长度","range":"3000 mm","cmc":"4,0 µm"},{"name":"平尺长度","range":"4000 mm","cmc":"4,6 µm"},{"name":"平尺长度","range":"5000 mm","cmc":"5,2 µm"}],"reference_zh":"内部程序 IW/KUM/20/01","regulatory_area_zh":"表面几何量","search_zh":"刀口尺 校准 — 表面几何量 内部程序；使用Talyvel 6 Taylor-Hobson差动水平仪的间接法；在固定地点 (S) 及固定地点以外 (P) 表面几何量 内部程序 使用Talyvel 6 Taylor-Hobson差动水平仪的间接法 在固定地点 (S) 及固定地点以外 (P) 平尺长度 平尺长度 平尺长度 平尺长度 平尺长度 平尺长度 平尺长度 平尺长度 平尺长度 内部程序 IW/KUM/20/01","technique_zh":"内部程序；使用Talyvel 6 Taylor-Hobson差动水平仪的间接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","使用Talyvel 6 Taylor-Hobson差动水平仪的间接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"刀口尺","methodology_cs":"Kalibrace — Geometrie povrchu","parameters_cs":[{"name":"délka pravítka","range":"250 mm","cmc":"1,0 µm"},{"name":"délka pravítka","range":"500 mm","cmc":"1,5 µm"},{"name":"délka pravítka","range":"1000 mm","cmc":"2,2 µm"},{"name":"délka pravítka","range":"1500 mm","cmc":"2,8 µm"},{"name":"délka pravítka","range":"2000 mm","cmc":"3,2 µm"},{"name":"délka pravítka","range":"2500 mm","cmc":"3,6 µm"},{"name":"délka pravítka","range":"3000 mm","cmc":"4,0 µm"},{"name":"délka pravítka","range":"4000 mm","cmc":"4,6 µm"},{"name":"délka pravítka","range":"5000 mm","cmc":"5,2 µm"}],"reference_cs":"Vnitřní postup IW/KUM/20/01","regulatory_area_cs":"Geometrie povrchu","search_cs":"Pravítka pro rovinnost Kalibrace — Geometrie povrchu Vnitřní postup; Nepřímá metoda s použitím diferenčních libel Talyvel 6 Taylor-Hobson; V trvalé lokalitě (S) i mimo ni (P) Geometrie povrchu Vnitřní postup Nepřímá metoda s použitím diferenčních libel Talyvel 6 Taylor-Hobson V trvalé lokalitě (S) i mimo ni (P) délka pravítka délka pravítka délka pravítka délka pravítka délka pravítka délka pravítka délka pravítka délka pravítka délka pravítka Vnitřní postup IW/KUM/20/01","technique_cs":"Vnitřní postup; Nepřímá metoda s použitím diferenčních libel Talyvel 6 Taylor-Hobson; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Nepřímá metoda s použitím diferenčních libel Talyvel 6 Taylor-Hobson","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Pravítka pro rovinnost"}],"has_pdf":true}