🇵🇱 ASPEL S.A. PL
Metrology & calibration
ASPEL S.A. is a calibration laboratory accredited by PCA under number AP 161 (Zabierzów, Poland). Its accreditation scope covers 20 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Calibrators, Power supplies, Analogue ammeters. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Direct method; At permanent location (S).
At a glance
- Accreditation number: PCA AP 161
- Calibration items in scope: 20
- Types of calibrated items: 21
- Calibration principles used: 2
- City: Zabierzów, Poland
- Valid until: 10-04-2028
- Accreditation number
- AP 161
- Accreditation body
- PCA
- Address
- Os. H.Sienkiewicza 33, 32-080 Zabierzów
- City
- Zabierzów, Poland
- Division
- Central Laboratory of Medical Equipment CELAMED
- Valid until
- 10-04-2028
What this laboratory calibrates (21)
- Multimeters — 6 calibration items
- Calibrators — 5 calibration items
- Power supplies — 3 calibration items
- Analogue ammeters — 2 calibration items
- Analogue voltmeters — 2 calibration items
- Clamp meters — 2 calibration items
- Digital ammeters — 2 calibration items
- Digital voltmeters — 2 calibration items
- Analogue frequency meters — 1 calibration item
- Analogue ohmmeters — 1 calibration item
- Digital frequency meters (square-wave signal) — 1 calibration item
- Digital ohmmeters — 1 calibration item
- Fixed resistors — 1 calibration item
- Non-quartz frequency generators — 1 calibration item
- Oscilloscopes — 1 calibration item
- and 6 more
Calibration principles (2)
- Internal procedure; At permanent location (S) — 12 calibration items
- Internal procedure; Direct method; At permanent location (S) — 8 calibration items
Certificate information
- Issue date
- 13.02.2025
- Issue no.
- 9
- Certificate date
- 16.03.2020
- Accreditation cycle
- 26.03.2024 — 10.04.2028
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (20)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Analogue voltmeters Digital voltmeters Multimeters Calibrators Power supplies |
Calibration — DC voltage 10 mV to 100 mV · CMC 0,012 % 100 mV to 1 V · CMC 0,0063 % 1 V to 10 V · CMC 0,0057 % 10 V to 100 V · CMC 0,0071 % 100 V to 500 V · CMC 0,0078 % 500 V to 1000 V · CMC 0,0083 % DC voltage |
Internal procedure; At permanent location (S) | MW-AL-01, MW-AL-02 | |
| 2 | Calibrators Power supplies |
Calibration — DC voltage 1 kV to 5 kV · CMC 0,25 % DC voltage |
Internal procedure; At permanent location (S) | MW-AL-02 | |
| 3 | Analogue ammeters Digital ammeters Multimeters |
Calibration — DC current 0,1 mA to 1 mA · CMC 0,10 % 1 mA to 10 mA · CMC 0,10 % 10 mA to 100 mA · CMC 0,086 % 100 mA to 1 A · CMC 0,33 % 1 A to 10 A · CMC 0,32 % DC current |
Internal procedure; At permanent location (S) | MW-AL-01 | |
| 4 | Clamp meters | Calibration — DC current 10 A to 200 A · CMC 0,32 % DC current |
Internal procedure; At permanent location (S) | MW-AL-03 | |
| 5 | Calibrators | Calibration — DC current 0,1 mA to 1 mA · CMC 0,076 % 1 mA to 10 mA · CMC 0,093 % 10 mA to 100 mA · CMC 0,076 % 100 mA to 1 A · CMC 0,13 % 1 A to 3 A · CMC 0,30 % 3 A to 5 A · CMC 0,23 % 5 A to 10 A · CMC 0,31 % DC current |
Internal procedure; At permanent location (S) | MW-AL-02 | |
| 6 | Analogue voltmeters Digital voltmeters Multimeters |
Calibration — AC voltage 40 Hz to 499 Hz — 10 mV to 100 mV · CMC 0,30 % 40 Hz to 499 Hz — 100 mV to 1 V · CMC 0,11 % 40 Hz to 499 Hz — 1 V to 10 V · CMC 0,09 % 40 Hz to 499 Hz — 10 V to 100 V · CMC 0,07 % 40 Hz to 499 Hz — 100 V to 1000 V · CMC 0,10 % 499 Hz to 4999 Hz — 10 mV to 100 mV · CMC 0,58 % 499 Hz to 4999 Hz — 100 mV to 1 V · CMC 0,16 % 499 Hz to 4999 Hz — 1 V to 1000 V · CMC 0,16 % AC voltage |
Internal procedure; At permanent location (S) | MW-AL-01 | |
| 7 | Calibrators Power supplies |
Calibration — AC voltage 40 Hz to 100 Hz — 1 kV to 5 kV · CMC 0,46 % 10 Hz to 20 kHz — 10 mV to 100 mV · CMC 0,10 % 10 Hz to 20 kHz — 100 mV to 100 V · CMC 0,09 % 10 Hz to 20 kHz — 100 V to 750 V · CMC 0,10 % 20 kHz to 50 kHz — 10 mV to 100 mV · CMC 0,15 % 20 kHz to 50 kHz — 100 mV to 1 V · CMC 0,14 % 20 kHz to 50 kHz — 1 V to 100 V · CMC 0,13 % 20 kHz to 50 kHz — 100 V to 750 V · CMC 0,20 % 50 kHz to 100 kHz — 10 mV to 100 mV · CMC 0,24 % 50 kHz to 100 kHz — 100 mV to 100 V · CMC 0,23 % 50 kHz to 100 kHz — 100 V to 750 V · CMC 0,29 % 100 kHz to 300 kHz — 10 mV to 100 mV · CMC 1,3 % 100 kHz to 300 kHz — 100 mV to 10 V · CMC 1,3 % 100 kHz to 300 kHz — 10 V to 100 V · CMC 1,3 % 100 kHz to 300 kHz — 100 V to 750 V · CMC 1,3 % AC voltage |
Internal procedure; At permanent location (S) | MW-AL-02 | |
| 8 | Analogue ammeters Digital ammeters Multimeters |
Calibration — AC current 40 Hz to 499 Hz — 0,1 mA to 1 mA · CMC 0,35 % 40 Hz to 499 Hz — 1 mA to 10 mA · CMC 0,21 % 40 Hz to 499 Hz — 10 mA to 100 mA · CMC 0,20 % 40 Hz to 499 Hz — 100 mA to 1 A · CMC 0,21 % 40 Hz to 499 Hz — 1 A to 10 A · CMC 0,46 % 499 Hz to 1999 Hz — 0,1 mA to 1 mA · CMC 0,61 % 1999 Hz to 4999 Hz — 0,1 mA to 1 mA · CMC 1,8 % 499 Hz to 4999 Hz — 1 mA to 10 mA · CMC 0,26 % 499 Hz to 4999 Hz — 10 mA to 100 mA · CMC 0,24 % 499 Hz to 4999 Hz — 100 mA to 1 A · CMC 0,24 % 499 Hz to 4999 Hz — 1 A to 10 A · CMC 0,48 % AC current |
Internal procedure; At permanent location (S) | MW-AL-01 | |
| 9 | Clamp meters | Calibration — AC current 40 Hz to 100 Hz — 10 A to 200 A · CMC 0,46 % AC current |
Internal procedure; At permanent location (S) | MW-AL-03 | |
| 10 | Calibrators | Calibration — AC current 3 Hz to 10000 Hz — 0,1 mA to 100 mA · CMC 0,18 % 3 Hz to 10000 Hz — 100 mA to 1 A · CMC 0,19 % 3 Hz to 10000 Hz — 1 A to 3 A · CMC 0,43 % 3 Hz to 10000 Hz — 3 A to 5 A · CMC 0,39 % 3 Hz to 10000 Hz — 5 A to 10 A · CMC 0,45 % AC current |
Internal procedure; At permanent location (S) | MW-AL-02 | |
| 11 | Fixed resistors Variable resistors |
Calibration — DC resistance 0 Ω to 100 Ω · CMC 0,013 % 100 Ω to 1 kΩ · CMC 0,0066 % 1 kΩ to 10 kΩ · CMC 0,0065 % 10 kΩ to 100 kΩ · CMC 0,0066 % 100 kΩ to 1 MΩ · CMC 0,010 % 1 MΩ to 10 MΩ · CMC 0,037 % 10 MΩ to 100 MΩ · CMC 0,46 % 100 MΩ to 1000 MΩ · CMC 4,6 % DC resistance |
Internal procedure; At permanent location (S) | MW-AL-05 | |
| 12 | Analogue ohmmeters Digital ohmmeters Multimeters |
Calibration — DC resistance 1 Ω to 10 Ω · CMC 0,1 % 10 Ω to 1 kΩ · CMC 0,06 % 1 kΩ to 1 MΩ · CMC 0,036 % 1 MΩ to 10 MΩ · CMC 0,12 % 10 MΩ to 100 MΩ · CMC 0,48 % DC resistance |
Internal procedure; At permanent location (S) | MW-AL-04 | |
| 13 | Period generators | Calibration — Time (time interval) 100 ns to 100 s · CMC 20 uHz · T² + 9 · 10⁻¹⁰ · T Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | MW-AL-06 | |
| 14 | Time interval generators | Calibration — Time (time interval) 100 ns to 1000 s · CMC 0,9 ns + 9 · 10⁻¹⁰ · T Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | MW-AL-06 | |
| 15 | Period meters | Calibration — Time (time interval) square-wave signal — 100 ns to 25 s · CMC 9 · 10⁻¹⁰ · T Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | MW-AL-07 | |
| 16 | Time interval meters | Calibration — Time (time interval) 100 ns to 1000 s · CMC 1,4 ns + 9 · 10⁻¹⁰ · T Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | MW-AL-07 | |
| 17 | Oscilloscopes | Calibration — Time (time interval) 100 ns to 25 s · CMC 1,4 ns + 2 · 10⁻⁵ · T Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | MW-AL-07 | |
| 18 | Quartz frequency generators | Calibration — Frequency 0,01 Hz to 3,0 GHz · CMC 20 µHz + 9 · 10⁻¹⁰ · F Frequency |
Internal procedure; Direct method; At permanent location (S) | MW-AL-06 | |
| 19 | Non-quartz frequency generators | Calibration — Frequency 0,01 Hz to 10 MHz · CMC 1 · 10⁻⁶ · F Frequency |
Internal procedure; Direct method; At permanent location (S) | MW-AL-06 | |
| 20 | Analogue frequency meters Digital frequency meters (square-wave signal) Multimeters |
Calibration — Frequency 0,04 Hz to 10 MHz · CMC 9 · 10⁻¹⁰ · F Frequency |
Internal procedure; Direct method; At permanent location (S) | MW-AL-07 | |
Reference standards (7)
MW-AL-01
MW-AL-02
MW-AL-03
MW-AL-04
MW-AL-05
MW-AL-06
MW-AL-07