PCA AP 161 • Zabierzów, Poland • 20 calibration items

Metrology & calibration

ASPEL S.A. is a calibration laboratory accredited by PCA under number AP 161 (Zabierzów, Poland). Its accreditation scope covers 20 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Calibrators, Power supplies, Analogue ammeters. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Direct method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 161
  • Calibration items in scope: 20
  • Types of calibrated items: 21
  • Calibration principles used: 2
  • City: Zabierzów, Poland
  • Valid until: 10-04-2028
Accreditation number
AP 161
Accreditation body
PCA
Address
Os. H.Sienkiewicza 33, 32-080 Zabierzów
City
Zabierzów, Poland
Division
Central Laboratory of Medical Equipment CELAMED
Valid until
10-04-2028

What this laboratory calibrates (21)

Calibration principles (2)

Certificate information

Issue date
13.02.2025
Issue no.
9
Certificate date
16.03.2020
Accreditation cycle
26.03.2024 — 10.04.2028
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (20)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Analogue voltmeters
Digital voltmeters
Multimeters
Calibrators
Power supplies
Calibration — DC voltage
10 mV to 100 mV · CMC 0,012 % 100 mV to 1 V · CMC 0,0063 % 1 V to 10 V · CMC 0,0057 % 10 V to 100 V · CMC 0,0071 % 100 V to 500 V · CMC 0,0078 % 500 V to 1000 V · CMC 0,0083 %
DC voltage
Internal procedure; At permanent location (S) MW-AL-01, MW-AL-02
2 Calibrators
Power supplies
Calibration — DC voltage
1 kV to 5 kV · CMC 0,25 %
DC voltage
Internal procedure; At permanent location (S) MW-AL-02
3 Analogue ammeters
Digital ammeters
Multimeters
Calibration — DC current
0,1 mA to 1 mA · CMC 0,10 % 1 mA to 10 mA · CMC 0,10 % 10 mA to 100 mA · CMC 0,086 % 100 mA to 1 A · CMC 0,33 % 1 A to 10 A · CMC 0,32 %
DC current
Internal procedure; At permanent location (S) MW-AL-01
4 Clamp meters Calibration — DC current
10 A to 200 A · CMC 0,32 %
DC current
Internal procedure; At permanent location (S) MW-AL-03
5 Calibrators Calibration — DC current
0,1 mA to 1 mA · CMC 0,076 % 1 mA to 10 mA · CMC 0,093 % 10 mA to 100 mA · CMC 0,076 % 100 mA to 1 A · CMC 0,13 % 1 A to 3 A · CMC 0,30 % 3 A to 5 A · CMC 0,23 % 5 A to 10 A · CMC 0,31 %
DC current
Internal procedure; At permanent location (S) MW-AL-02
6 Analogue voltmeters
Digital voltmeters
Multimeters
Calibration — AC voltage
40 Hz to 499 Hz — 10 mV to 100 mV · CMC 0,30 % 40 Hz to 499 Hz — 100 mV to 1 V · CMC 0,11 % 40 Hz to 499 Hz — 1 V to 10 V · CMC 0,09 % 40 Hz to 499 Hz — 10 V to 100 V · CMC 0,07 % 40 Hz to 499 Hz — 100 V to 1000 V · CMC 0,10 % 499 Hz to 4999 Hz — 10 mV to 100 mV · CMC 0,58 % 499 Hz to 4999 Hz — 100 mV to 1 V · CMC 0,16 % 499 Hz to 4999 Hz — 1 V to 1000 V · CMC 0,16 %
AC voltage
Internal procedure; At permanent location (S) MW-AL-01
7 Calibrators
Power supplies
Calibration — AC voltage
40 Hz to 100 Hz — 1 kV to 5 kV · CMC 0,46 % 10 Hz to 20 kHz — 10 mV to 100 mV · CMC 0,10 % 10 Hz to 20 kHz — 100 mV to 100 V · CMC 0,09 % 10 Hz to 20 kHz — 100 V to 750 V · CMC 0,10 % 20 kHz to 50 kHz — 10 mV to 100 mV · CMC 0,15 % 20 kHz to 50 kHz — 100 mV to 1 V · CMC 0,14 % 20 kHz to 50 kHz — 1 V to 100 V · CMC 0,13 % 20 kHz to 50 kHz — 100 V to 750 V · CMC 0,20 % 50 kHz to 100 kHz — 10 mV to 100 mV · CMC 0,24 % 50 kHz to 100 kHz — 100 mV to 100 V · CMC 0,23 % 50 kHz to 100 kHz — 100 V to 750 V · CMC 0,29 % 100 kHz to 300 kHz — 10 mV to 100 mV · CMC 1,3 % 100 kHz to 300 kHz — 100 mV to 10 V · CMC 1,3 % 100 kHz to 300 kHz — 10 V to 100 V · CMC 1,3 % 100 kHz to 300 kHz — 100 V to 750 V · CMC 1,3 %
AC voltage
Internal procedure; At permanent location (S) MW-AL-02
8 Analogue ammeters
Digital ammeters
Multimeters
Calibration — AC current
40 Hz to 499 Hz — 0,1 mA to 1 mA · CMC 0,35 % 40 Hz to 499 Hz — 1 mA to 10 mA · CMC 0,21 % 40 Hz to 499 Hz — 10 mA to 100 mA · CMC 0,20 % 40 Hz to 499 Hz — 100 mA to 1 A · CMC 0,21 % 40 Hz to 499 Hz — 1 A to 10 A · CMC 0,46 % 499 Hz to 1999 Hz — 0,1 mA to 1 mA · CMC 0,61 % 1999 Hz to 4999 Hz — 0,1 mA to 1 mA · CMC 1,8 % 499 Hz to 4999 Hz — 1 mA to 10 mA · CMC 0,26 % 499 Hz to 4999 Hz — 10 mA to 100 mA · CMC 0,24 % 499 Hz to 4999 Hz — 100 mA to 1 A · CMC 0,24 % 499 Hz to 4999 Hz — 1 A to 10 A · CMC 0,48 %
AC current
Internal procedure; At permanent location (S) MW-AL-01
9 Clamp meters Calibration — AC current
40 Hz to 100 Hz — 10 A to 200 A · CMC 0,46 %
AC current
Internal procedure; At permanent location (S) MW-AL-03
10 Calibrators Calibration — AC current
3 Hz to 10000 Hz — 0,1 mA to 100 mA · CMC 0,18 % 3 Hz to 10000 Hz — 100 mA to 1 A · CMC 0,19 % 3 Hz to 10000 Hz — 1 A to 3 A · CMC 0,43 % 3 Hz to 10000 Hz — 3 A to 5 A · CMC 0,39 % 3 Hz to 10000 Hz — 5 A to 10 A · CMC 0,45 %
AC current
Internal procedure; At permanent location (S) MW-AL-02
11 Fixed resistors
Variable resistors
Calibration — DC resistance
0 Ω to 100 Ω · CMC 0,013 % 100 Ω to 1 kΩ · CMC 0,0066 % 1 kΩ to 10 kΩ · CMC 0,0065 % 10 kΩ to 100 kΩ · CMC 0,0066 % 100 kΩ to 1 MΩ · CMC 0,010 % 1 MΩ to 10 MΩ · CMC 0,037 % 10 MΩ to 100 MΩ · CMC 0,46 % 100 MΩ to 1000 MΩ · CMC 4,6 %
DC resistance
Internal procedure; At permanent location (S) MW-AL-05
12 Analogue ohmmeters
Digital ohmmeters
Multimeters
Calibration — DC resistance
1 Ω to 10 Ω · CMC 0,1 % 10 Ω to 1 kΩ · CMC 0,06 % 1 kΩ to 1 MΩ · CMC 0,036 % 1 MΩ to 10 MΩ · CMC 0,12 % 10 MΩ to 100 MΩ · CMC 0,48 %
DC resistance
Internal procedure; At permanent location (S) MW-AL-04
13 Period generators Calibration — Time (time interval)
100 ns to 100 s · CMC 20 uHz · T² + 9 · 10⁻¹⁰ · T
Time (time interval)
Internal procedure; Direct method; At permanent location (S) MW-AL-06
14 Time interval generators Calibration — Time (time interval)
100 ns to 1000 s · CMC 0,9 ns + 9 · 10⁻¹⁰ · T
Time (time interval)
Internal procedure; Direct method; At permanent location (S) MW-AL-06
15 Period meters Calibration — Time (time interval)
square-wave signal — 100 ns to 25 s · CMC 9 · 10⁻¹⁰ · T
Time (time interval)
Internal procedure; Direct method; At permanent location (S) MW-AL-07
16 Time interval meters Calibration — Time (time interval)
100 ns to 1000 s · CMC 1,4 ns + 9 · 10⁻¹⁰ · T
Time (time interval)
Internal procedure; Direct method; At permanent location (S) MW-AL-07
17 Oscilloscopes Calibration — Time (time interval)
100 ns to 25 s · CMC 1,4 ns + 2 · 10⁻⁵ · T
Time (time interval)
Internal procedure; Direct method; At permanent location (S) MW-AL-07
18 Quartz frequency generators Calibration — Frequency
0,01 Hz to 3,0 GHz · CMC 20 µHz + 9 · 10⁻¹⁰ · F
Frequency
Internal procedure; Direct method; At permanent location (S) MW-AL-06
19 Non-quartz frequency generators Calibration — Frequency
0,01 Hz to 10 MHz · CMC 1 · 10⁻⁶ · F
Frequency
Internal procedure; Direct method; At permanent location (S) MW-AL-06
20 Analogue frequency meters
Digital frequency meters (square-wave signal)
Multimeters
Calibration — Frequency
0,04 Hz to 10 MHz · CMC 9 · 10⁻¹⁰ · F
Frequency
Internal procedure; Direct method; At permanent location (S) MW-AL-07

Reference standards (7)

MW-AL-01
MW-AL-02
MW-AL-03
MW-AL-04
MW-AL-05
MW-AL-06
MW-AL-07

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20161