{"lab":{"_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","imported_at":"2026-11-13T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"Os. H.Sienkiewicza 33, 32-080 Zabierzów","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"16.03.2020","city":"Zabierzów","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.","cycle_from":"26.03.2024","cycle_to":"10.04.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"7.01","pl":"napięcie DC","en":"DC voltage","de":"Gleichspannung","zh":"直流电压","cs":"stejnosměrné napětí (DC)"},{"codes":"7.02","pl":"prąd DC","en":"DC current","de":"DC-Strom","zh":"直流电流","cs":"proud DC"},{"codes":"7.03","pl":"napięcie AC","en":"AC voltage","de":"AC-Spannung","zh":"交流电压","cs":"napětí AC"},{"codes":"7.04","pl":"prąd AC","en":"AC current","de":"AC-Strom","zh":"交流电流","cs":"proud AC"},{"codes":"7.05","pl":"rezystancja DC","en":"DC resistance","de":"DC-Widerstand","zh":"直流电阻","cs":"odpor DC"},{"codes":"10.01","pl":"czas (przedział czasu)","en":"time (time interval)","de":"Zeit (Zeitintervall)","zh":"时间（时间间隔）","cs":"čas (časový interval)"},{"codes":"10.02","pl":"częstotliwość","en":"frequency","de":"Frequenz","zh":"频率","cs":"frekvence"}],"has_en":true,"has_zh":true,"issue":{"no":"9","date":"13.02.2025"},"issue_date":"13.02.2025","issue_number":"9","lab_division":"Centralne Laboratorium Aparatury Medycznej CELAMED","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[19.799043,50.1188378]},"map_coord":[50.1188378,19.799043],"map_geo":"nominatim-street","methods_count":20,"name":"ASPEL S.A.","parse_date":"2026-11-13T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-13T12:00:00.000Z","pdf_files":["AP_161.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: napięcie DC, prąd DC, napięcie AC, prąd AC, rezystancja DC, czas (przedział czasu), częstotliwość. W stałej lokalizacji (S).","search_text":"aspel s.a. centralne laboratorium aparatury medycznej celamed os. h.sienkiewicza 33, 32-080 zabierzów laboratorium wzorcujące. wielkości mierzone: napięcie dc, prąd dc, napięcie ac, prąd ac, rezystancja dc, czas (przedział czasu), częstotliwość. w stałej lokalizacji (s). ap 161 ap161 laboratorium wzorcujące wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance time (time interval) frequency aspel s.a. centralne laboratorium aparatury medycznej celamed os. h.sienkiewicza 33, 32-080 zabierzow laboratorium wzorcujace. wielkosci mierzone: napiecie dc, prad dc, napiecie ac, prad ac, rezystancja dc, czas (przedzial czasu), czestotliwosc. w stalej lokalizacji (s). ap 161 ap161 laboratorium wzorcujace wzorcowanie kalibracja dc voltage dc current ac voltage ac current dc resistance time (time interval) frequency","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20161,podmiot.html","source_pdf_sha256":"5b79803c3de2b8bc795d205ad72d81da214078bcb88db2bc37463536b18d8b8e","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/13/e0f87588060f15f1b1ce3b60414f4909/AP%20161.pdf","status":"active","updated_at":"2026-11-13T12:00:00.000Z","valid_from":"11-04-2016","valid_until":"10-04-2028","website":"www.celamed.pl","lab_division_en":"Central Laboratory of Medical Equipment CELAMED","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Zentrallabor für Medizingeräte CELAMED","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。以百分比表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"CELAMED 医疗设备中心实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Centrální laboratoř zdravotnických přístrojů CELAMED","pelny_cs":true},"methods":[{"_id":"a93353952c77311d142412f6","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Mierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry\nKalibratory\nZasilacze","test_object_en":"Analogue voltmeters\nDigital voltmeters\nMultimeters\nCalibrators\nPower supplies","methodology":"Wzorcowanie — Napięcia DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"10 mV do 100 mV","cmc":"0,012 %"},{"name":"","range":"100 mV do 1 V","cmc":"0,0063 %"},{"name":"","range":"1 V do 10 V","cmc":"0,0057 %"},{"name":"","range":"10 V do 100 V","cmc":"0,0071 %"},{"name":"","range":"100 V do 500 V","cmc":"0,0078 %"},{"name":"","range":"500 V do 1000 V","cmc":"0,0083 %"}],"parameters_en":[{"name":"","range":"10 mV to 100 mV","cmc":"0,012 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,0063 %"},{"name":"","range":"1 V to 10 V","cmc":"0,0057 %"},{"name":"","range":"10 V to 100 V","cmc":"0,0071 %"},{"name":"","range":"100 V to 500 V","cmc":"0,0078 %"},{"name":"","range":"500 V to 1000 V","cmc":"0,0083 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcia DC\nZakres:\n10 mV do 100 mV CMC 0,012 %\n100 mV do 1 V CMC 0,0063 %\n1 V do 10 V CMC 0,0057 %\n10 V do 100 V CMC 0,0071 %\n100 V do 500 V CMC 0,0078 %\n500 V do 1000 V CMC 0,0083 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-01, MW-AL-02","norm_bases":["MW-AL-01","MW-AL-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcia DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry\nKalibratory\nZasilacze Wzorcowanie — Napięcia DC\nZakres:\n10 mV do 100 mV CMC 0,012 %\n100 mV do 1 V CMC 0,0063 %\n1 V do 10 V CMC 0,0057 %\n10 V do 100 V CMC 0,0071 %\n100 V do 500 V CMC 0,0078 %\n500 V do 1000 V CMC 0,0083 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-01, MW-AL-02 Mierniki napiecia analogowe\nMierniki napiecia cyfrowe\nMultimetry\nKalibratory\nZasilacze Wzorcowanie — Napiecia DC\nZakres:\n10 mV do 100 mV CMC 0,012 %\n100 mV do 1 V CMC 0,0063 %\n1 V do 10 V CMC 0,0057 %\n10 V do 100 V CMC 0,0071 %\n100 V do 500 V CMC 0,0078 %\n500 V do 1000 V CMC 0,0083 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-01, MW-AL-02","search_en":"Analogue voltmeters Digital voltmeters Multimeters Calibrators Power supplies Calibration — DC voltage Internal procedure; At permanent location (S) DC voltage Internal procedure At permanent location (S) MW-AL-01, MW-AL-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Gleichspannungen","parameters_de":[{"name":"","range":"10 mV to 100 mV","cmc":"0,012 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,0063 %"},{"name":"","range":"1 V to 10 V","cmc":"0,0057 %"},{"name":"","range":"10 V to 100 V","cmc":"0,0071 %"},{"name":"","range":"100 V bis 500 V","cmc":"0,0078 %"},{"name":"","range":"500 V to 1000 V","cmc":"0,0083 %"}],"regulatory_area_de":"Gleichspannungen","search_de":"Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte Multimeter Kalibratoren Netzgeräte Kalibrierung — Gleichspannungen Internes Verfahren; Am festen Standort (S) Gleichspannungen Internes Verfahren Am festen Standort (S) MW-AL-01, MW-AL-02","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\nMultimeter\nKalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"10 mV to 100 mV","cmc":"0,012 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,0063 %"},{"name":"","range":"1 V to 10 V","cmc":"0,0057 %"},{"name":"","range":"10 V to 100 V","cmc":"0,0071 %"},{"name":"","range":"100 V to 500 V","cmc":"0,0078 %"},{"name":"","range":"500 V to 1000 V","cmc":"0,0083 %"}],"regulatory_area_zh":"直流电压","search_zh":"模拟电压表 数字电压表 万用表 校准器 电源 校准 — 直流电压 内部程序；在固定地点 (S) 直流电压 内部程序 在固定地点 (S) MW-AL-01, MW-AL-02","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"模拟电压表\n数字电压表\n万用表\n校准器\n电源","methodology_cs":"Kalibrace — Stejnosměrná napětí","parameters_cs":[{"name":"","range":"10 mV to 100 mV","cmc":"0,012 %"},{"name":"","range":"100 mV to 1 V","cmc":"0,0063 %"},{"name":"","range":"1 V to 10 V","cmc":"0,0057 %"},{"name":"","range":"10 V to 100 V","cmc":"0,0071 %"},{"name":"","range":"100 V to 500 V","cmc":"0,0078 %"},{"name":"","range":"500 V to 1000 V","cmc":"0,0083 %"}],"regulatory_area_cs":"Stejnosměrná napětí","search_cs":"Analogové měřiče napětí Digitální měřiče napětí Multimetry Kalibrátory Napájecí zdroje Kalibrace — Stejnosměrná napětí Vnitřní postup; Ve stálé lokalitě (S) Stejnosměrná napětí Vnitřní postup Ve stálé lokalitě (S) MW-AL-01, MW-AL-02","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče napětí\nDigitální měřiče napětí\nMultimetry\nKalibrátory\nNapájecí zdroje"},{"_id":"60b42c6b37a9d71851fced3f","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Napięcia DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"1 kV do 5 kV","cmc":"0,25 %"}],"parameters_en":[{"name":"","range":"1 kV to 5 kV","cmc":"0,25 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcia DC\n1 kV do 5 kV CMC 0,25 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-02","norm_bases":["MW-AL-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcia DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory\nZasilacze Wzorcowanie — Napięcia DC\n1 kV do 5 kV CMC 0,25 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-02 Kalibratory\nZasilacze Wzorcowanie — Napiecia DC\n1 kV do 5 kV CMC 0,25 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-02","search_en":"Calibrators Power supplies Calibration — DC voltage Internal procedure; At permanent location (S) DC voltage Internal procedure At permanent location (S) MW-AL-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Gleichspannungen","parameters_de":[{"name":"","range":"1 kV bis 5 kV","cmc":"0,25 %"}],"regulatory_area_de":"Gleichspannungen","search_de":"Kalibratoren Netzgeräte Kalibrierung — Gleichspannungen Internes Verfahren; Am festen Standort (S) Gleichspannungen Internes Verfahren Am festen Standort (S) MW-AL-02","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"1 kV to 5 kV","cmc":"0,25 %"}],"regulatory_area_zh":"直流电压","search_zh":"校准器 电源 校准 — 直流电压 内部程序；在固定地点 (S) 直流电压 内部程序 在固定地点 (S) MW-AL-02","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Stejnosměrná napětí","parameters_cs":[{"name":"","range":"1 kV to 5 kV","cmc":"0,25 %"}],"regulatory_area_cs":"Stejnosměrná napětí","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Stejnosměrná napětí Vnitřní postup; Ve stálé lokalitě (S) Stejnosměrná napětí Vnitřní postup Ve stálé lokalitě (S) MW-AL-02","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"65ce3222be3154fa06670de6","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Mierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry","test_object_en":"Analogue ammeters\nDigital ammeters\nMultimeters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,1 mA do 1 mA","cmc":"0,10 %"},{"name":"","range":"1 mA do 10 mA","cmc":"0,10 %"},{"name":"","range":"10 mA do 100 mA","cmc":"0,086 %"},{"name":"","range":"100 mA do 1 A","cmc":"0,33 %"},{"name":"","range":"1 A do 10 A","cmc":"0,32 %"}],"parameters_en":[{"name":"","range":"0,1 mA to 1 mA","cmc":"0,10 %"},{"name":"","range":"1 mA to 10 mA","cmc":"0,10 %"},{"name":"","range":"10 mA to 100 mA","cmc":"0,086 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,33 %"},{"name":"","range":"1 A to 10 A","cmc":"0,32 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,1 mA do 1 mA CMC 0,10 %\n1 mA do 10 mA CMC 0,10 %\n10 mA do 100 mA CMC 0,086 %\n100 mA do 1 A CMC 0,33 %\n1 A do 10 A CMC 0,32 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-01","norm_bases":["MW-AL-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry Wzorcowanie — Prąd DC\nZakres:\n0,1 mA do 1 mA CMC 0,10 %\n1 mA do 10 mA CMC 0,10 %\n10 mA do 100 mA CMC 0,086 %\n100 mA do 1 A CMC 0,33 %\n1 A do 10 A CMC 0,32 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-01 Mierniki pradu analogowe\nMierniki pradu cyfrowe\nMultimetry Wzorcowanie — Prad DC\nZakres:\n0,1 mA do 1 mA CMC 0,10 %\n1 mA do 10 mA CMC 0,10 %\n10 mA do 100 mA CMC 0,086 %\n100 mA do 1 A CMC 0,33 %\n1 A do 10 A CMC 0,32 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-01","search_en":"Analogue ammeters Digital ammeters Multimeters Calibration — DC current Internal procedure; At permanent location (S) DC current Internal procedure At permanent location (S) MW-AL-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,1 mA to 1 mA","cmc":"0,10 %"},{"name":"","range":"1 mA to 10 mA","cmc":"0,10 %"},{"name":"","range":"10 mA bis 100 mA","cmc":"0,086 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,33 %"},{"name":"","range":"1 A to 10 A","cmc":"0,32 %"}],"regulatory_area_de":"DC-Strom","search_de":"Analoge Strommessgeräte Digitale Strommessgeräte Multimeter Kalibrierung — DC-Strom Internes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Am festen Standort (S) MW-AL-01","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Strommessgeräte\nDigitale Strommessgeräte\nMultimeter","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,1 mA to 1 mA","cmc":"0,10 %"},{"name":"","range":"1 mA to 10 mA","cmc":"0,10 %"},{"name":"","range":"10 mA to 100 mA","cmc":"0,086 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,33 %"},{"name":"","range":"1 A to 10 A","cmc":"0,32 %"}],"regulatory_area_zh":"直流电流","search_zh":"模拟电流表 数字电流表 万用表 校准 — 直流电流 内部程序；在固定地点 (S) 直流电流 内部程序 在固定地点 (S) MW-AL-01","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"模拟电流表\n数字电流表\n万用表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,1 mA to 1 mA","cmc":"0,10 %"},{"name":"","range":"1 mA to 10 mA","cmc":"0,10 %"},{"name":"","range":"10 mA to 100 mA","cmc":"0,086 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,33 %"},{"name":"","range":"1 A to 10 A","cmc":"0,32 %"}],"regulatory_area_cs":"Proud DC","search_cs":"Analogové měřiče proudu Digitální měřiče proudu Multimetry Kalibrace — Proud DC Vnitřní postup; Ve stálé lokalitě (S) Proud DC Vnitřní postup Ve stálé lokalitě (S) MW-AL-01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče proudu\nDigitální měřiče proudu\nMultimetry"},{"_id":"b931358470b7961bc2f3a938","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"10 A do 200 A","cmc":"0,32 %"}],"parameters_en":[{"name":"","range":"10 A to 200 A","cmc":"0,32 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\n10 A do 200 A CMC 0,32 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-03","norm_bases":["MW-AL-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki cęgowe Wzorcowanie — Prąd DC\n10 A do 200 A CMC 0,32 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-03 Mierniki cegowe Wzorcowanie — Prad DC\n10 A do 200 A CMC 0,32 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-03","search_en":"Clamp meters Calibration — DC current Internal procedure; At permanent location (S) DC current Internal procedure At permanent location (S) MW-AL-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"10 A to 200 A","cmc":"0,32 %"}],"regulatory_area_de":"DC-Strom","search_de":"Zangenmessgeräte Kalibrierung — DC-Strom Internes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Am festen Standort (S) MW-AL-03","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"10 A to 200 A","cmc":"0,32 %"}],"regulatory_area_zh":"直流电流","search_zh":"钳形表 校准 — 直流电流 内部程序；在固定地点 (S) 直流电流 内部程序 在固定地点 (S) MW-AL-03","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"10 A to 200 A","cmc":"0,32 %"}],"regulatory_area_cs":"Proud DC","search_cs":"Klešťové měřiče Kalibrace — Proud DC Vnitřní postup; Ve stálé lokalitě (S) Proud DC Vnitřní postup Ve stálé lokalitě (S) MW-AL-03","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Klešťové měřiče"},{"_id":"989c0e2cc52480a8fe6fd8b0","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Kalibratory","test_object_en":"Calibrators","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,1 mA do 1 mA","cmc":"0,076 %"},{"name":"","range":"1 mA do 10 mA","cmc":"0,093 %"},{"name":"","range":"10 mA do 100 mA","cmc":"0,076 %"},{"name":"","range":"100 mA do 1 A","cmc":"0,13 %"},{"name":"","range":"1 A do 3 A","cmc":"0,30 %"},{"name":"","range":"3 A do 5 A","cmc":"0,23 %"},{"name":"","range":"5 A do 10 A","cmc":"0,31 %"}],"parameters_en":[{"name":"","range":"0,1 mA to 1 mA","cmc":"0,076 %"},{"name":"","range":"1 mA to 10 mA","cmc":"0,093 %"},{"name":"","range":"10 mA to 100 mA","cmc":"0,076 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,13 %"},{"name":"","range":"1 A to 3 A","cmc":"0,30 %"},{"name":"","range":"3 A to 5 A","cmc":"0,23 %"},{"name":"","range":"5 A to 10 A","cmc":"0,31 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,1 mA do 1 mA CMC 0,076 %\n1 mA do 10 mA CMC 0,093 %\n10 mA do 100 mA CMC 0,076 %\n100 mA do 1 A CMC 0,13 %\n1 A do 3 A CMC 0,30 %\n3 A do 5 A CMC 0,23 %\n5 A do 10 A CMC 0,31 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-02","norm_bases":["MW-AL-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory Wzorcowanie — Prąd DC\nZakres:\n0,1 mA do 1 mA CMC 0,076 %\n1 mA do 10 mA CMC 0,093 %\n10 mA do 100 mA CMC 0,076 %\n100 mA do 1 A CMC 0,13 %\n1 A do 3 A CMC 0,30 %\n3 A do 5 A CMC 0,23 %\n5 A do 10 A CMC 0,31 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-02 Kalibratory Wzorcowanie — Prad DC\nZakres:\n0,1 mA do 1 mA CMC 0,076 %\n1 mA do 10 mA CMC 0,093 %\n10 mA do 100 mA CMC 0,076 %\n100 mA do 1 A CMC 0,13 %\n1 A do 3 A CMC 0,30 %\n3 A do 5 A CMC 0,23 %\n5 A do 10 A CMC 0,31 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-02","search_en":"Calibrators Calibration — DC current Internal procedure; At permanent location (S) DC current Internal procedure At permanent location (S) MW-AL-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,1 mA to 1 mA","cmc":"0,076 %"},{"name":"","range":"1 mA to 10 mA","cmc":"0,093 %"},{"name":"","range":"10 mA bis 100 mA","cmc":"0,076 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,13 %"},{"name":"","range":"1 A to 3 A","cmc":"0,30 %"},{"name":"","range":"3 A to 5 A","cmc":"0,23 %"},{"name":"","range":"5 A to 10 A","cmc":"0,31 %"}],"regulatory_area_de":"DC-Strom","search_de":"Kalibratoren Kalibrierung — DC-Strom Internes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Am festen Standort (S) MW-AL-02","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,1 mA to 1 mA","cmc":"0,076 %"},{"name":"","range":"1 mA to 10 mA","cmc":"0,093 %"},{"name":"","range":"10 mA to 100 mA","cmc":"0,076 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,13 %"},{"name":"","range":"1 A to 3 A","cmc":"0,30 %"},{"name":"","range":"3 A to 5 A","cmc":"0,23 %"},{"name":"","range":"5 A to 10 A","cmc":"0,31 %"}],"regulatory_area_zh":"直流电流","search_zh":"校准器 校准 — 直流电流 内部程序；在固定地点 (S) 直流电流 内部程序 在固定地点 (S) MW-AL-02","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,1 mA to 1 mA","cmc":"0,076 %"},{"name":"","range":"1 mA to 10 mA","cmc":"0,093 %"},{"name":"","range":"10 mA to 100 mA","cmc":"0,076 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,13 %"},{"name":"","range":"1 A to 3 A","cmc":"0,30 %"},{"name":"","range":"3 A to 5 A","cmc":"0,23 %"},{"name":"","range":"5 A to 10 A","cmc":"0,31 %"}],"regulatory_area_cs":"Proud DC","search_cs":"Kalibrátory Kalibrace — Proud DC Vnitřní postup; Ve stálé lokalitě (S) Proud DC Vnitřní postup Ve stálé lokalitě (S) MW-AL-02","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory"},{"_id":"7d4544cd3f00fe8b8210ecd6","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Mierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry","test_object_en":"Analogue voltmeters\nDigital voltmeters\nMultimeters","methodology":"Wzorcowanie — Napięcia AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"40 Hz do 499 Hz","range":"10 mV do 100 mV","cmc":"0,30 %"},{"name":"40 Hz do 499 Hz","range":"100 mV do 1 V","cmc":"0,11 %"},{"name":"40 Hz do 499 Hz","range":"1 V do 10 V","cmc":"0,09 %"},{"name":"40 Hz do 499 Hz","range":"10 V do 100 V","cmc":"0,07 %"},{"name":"40 Hz do 499 Hz","range":"100 V do 1000 V","cmc":"0,10 %"},{"name":"499 Hz do 4999 Hz","range":"10 mV do 100 mV","cmc":"0,58 %"},{"name":"499 Hz do 4999 Hz","range":"100 mV do 1 V","cmc":"0,16 %"},{"name":"499 Hz do 4999 Hz","range":"1 V do 1000 V","cmc":"0,16 %"}],"parameters_en":[{"name":"40 Hz to 499 Hz","range":"10 mV to 100 mV","cmc":"0,30 %"},{"name":"40 Hz to 499 Hz","range":"100 mV to 1 V","cmc":"0,11 %"},{"name":"40 Hz to 499 Hz","range":"1 V to 10 V","cmc":"0,09 %"},{"name":"40 Hz to 499 Hz","range":"10 V to 100 V","cmc":"0,07 %"},{"name":"40 Hz to 499 Hz","range":"100 V to 1000 V","cmc":"0,10 %"},{"name":"499 Hz to 4999 Hz","range":"10 mV to 100 mV","cmc":"0,58 %"},{"name":"499 Hz to 4999 Hz","range":"100 mV to 1 V","cmc":"0,16 %"},{"name":"499 Hz to 4999 Hz","range":"1 V to 1000 V","cmc":"0,16 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcia AC\nZakres:\n40 Hz do 499 Hz 10 mV do 100 mV CMC 0,30 %\n40 Hz do 499 Hz 100 mV do 1 V CMC 0,11 %\n40 Hz do 499 Hz 1 V do 10 V CMC 0,09 %\n40 Hz do 499 Hz 10 V do 100 V CMC 0,07 %\n40 Hz do 499 Hz 100 V do 1000 V CMC 0,10 %\n499 Hz do 4999 Hz 10 mV do 100 mV CMC 0,58 %\n499 Hz do 4999 Hz 100 mV do 1 V CMC 0,16 %\n499 Hz do 4999 Hz 1 V do 1000 V CMC 0,16 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-01","norm_bases":["MW-AL-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcia AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry Wzorcowanie — Napięcia AC\nZakres:\n40 Hz do 499 Hz 10 mV do 100 mV CMC 0,30 %\n40 Hz do 499 Hz 100 mV do 1 V CMC 0,11 %\n40 Hz do 499 Hz 1 V do 10 V CMC 0,09 %\n40 Hz do 499 Hz 10 V do 100 V CMC 0,07 %\n40 Hz do 499 Hz 100 V do 1000 V CMC 0,10 %\n499 Hz do 4999 Hz 10 mV do 100 mV CMC 0,58 %\n499 Hz do 4999 Hz 100 mV do 1 V CMC 0,16 %\n499 Hz do 4999 Hz 1 V do 1000 V CMC 0,16 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-01 Mierniki napiecia analogowe\nMierniki napiecia cyfrowe\nMultimetry Wzorcowanie — Napiecia AC\nZakres:\n40 Hz do 499 Hz 10 mV do 100 mV CMC 0,30 %\n40 Hz do 499 Hz 100 mV do 1 V CMC 0,11 %\n40 Hz do 499 Hz 1 V do 10 V CMC 0,09 %\n40 Hz do 499 Hz 10 V do 100 V CMC 0,07 %\n40 Hz do 499 Hz 100 V do 1000 V CMC 0,10 %\n499 Hz do 4999 Hz 10 mV do 100 mV CMC 0,58 %\n499 Hz do 4999 Hz 100 mV do 1 V CMC 0,16 %\n499 Hz do 4999 Hz 1 V do 1000 V CMC 0,16 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-01","search_en":"Analogue voltmeters Digital voltmeters Multimeters Calibration — AC voltage Internal procedure; At permanent location (S) AC voltage Internal procedure At permanent location (S) 40 Hz to 499 Hz 40 Hz to 499 Hz 40 Hz to 499 Hz 40 Hz to 499 Hz 40 Hz to 499 Hz 499 Hz to 4999 Hz 499 Hz to 4999 Hz 499 Hz to 4999 Hz MW-AL-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannungen","parameters_de":[{"name":"40 Hz bis 499 Hz","range":"10 mV to 100 mV","cmc":"0,30 %"},{"name":"40 Hz bis 499 Hz","range":"100 mV to 1 V","cmc":"0,11 %"},{"name":"40 Hz bis 499 Hz","range":"1 V to 10 V","cmc":"0,09 %"},{"name":"40 Hz bis 499 Hz","range":"10 V to 100 V","cmc":"0,07 %"},{"name":"40 Hz bis 499 Hz","range":"100 V to 1000 V","cmc":"0,10 %"},{"name":"499 Hz bis 4999 Hz","range":"10 mV to 100 mV","cmc":"0,58 %"},{"name":"499 Hz bis 4999 Hz","range":"100 mV to 1 V","cmc":"0,16 %"},{"name":"499 Hz bis 4999 Hz","range":"1 V to 1000 V","cmc":"0,16 %"}],"regulatory_area_de":"Wechselspannungen","search_de":"Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte Multimeter Kalibrierung — Wechselspannungen Internes Verfahren; Am festen Standort (S) Wechselspannungen Internes Verfahren Am festen Standort (S) 40 Hz bis 499 Hz 40 Hz bis 499 Hz 40 Hz bis 499 Hz 40 Hz bis 499 Hz 40 Hz bis 499 Hz 499 Hz bis 4999 Hz 499 Hz bis 4999 Hz 499 Hz bis 4999 Hz MW-AL-01","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\nMultimeter","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"40 Hz 至 499 Hz","range":"10 mV to 100 mV","cmc":"0,30 %"},{"name":"40 Hz 至 499 Hz","range":"100 mV to 1 V","cmc":"0,11 %"},{"name":"40 Hz 至 499 Hz","range":"1 V to 10 V","cmc":"0,09 %"},{"name":"40 Hz 至 499 Hz","range":"10 V to 100 V","cmc":"0,07 %"},{"name":"40 Hz 至 499 Hz","range":"100 V to 1000 V","cmc":"0,10 %"},{"name":"499 Hz 至 4999 Hz","range":"10 mV to 100 mV","cmc":"0,58 %"},{"name":"499 Hz 至 4999 Hz","range":"100 mV to 1 V","cmc":"0,16 %"},{"name":"499 Hz 至 4999 Hz","range":"1 V to 1000 V","cmc":"0,16 %"}],"regulatory_area_zh":"交流电压","search_zh":"模拟电压表 数字电压表 万用表 校准 — 交流电压 内部程序；在固定地点 (S) 交流电压 内部程序 在固定地点 (S) 40 Hz 至 499 Hz 40 Hz 至 499 Hz 40 Hz 至 499 Hz 40 Hz 至 499 Hz 40 Hz 至 499 Hz 499 Hz 至 4999 Hz 499 Hz 至 4999 Hz 499 Hz 至 4999 Hz MW-AL-01","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"模拟电压表\n数字电压表\n万用表","methodology_cs":"Kalibrace — Střídavá napětí","parameters_cs":[{"name":"40 Hz až 499 Hz","range":"10 mV to 100 mV","cmc":"0,30 %"},{"name":"40 Hz až 499 Hz","range":"100 mV to 1 V","cmc":"0,11 %"},{"name":"40 Hz až 499 Hz","range":"1 V to 10 V","cmc":"0,09 %"},{"name":"40 Hz až 499 Hz","range":"10 V to 100 V","cmc":"0,07 %"},{"name":"40 Hz až 499 Hz","range":"100 V to 1000 V","cmc":"0,10 %"},{"name":"499 Hz až 4999 Hz","range":"10 mV to 100 mV","cmc":"0,58 %"},{"name":"499 Hz až 4999 Hz","range":"100 mV to 1 V","cmc":"0,16 %"},{"name":"499 Hz až 4999 Hz","range":"1 V to 1000 V","cmc":"0,16 %"}],"regulatory_area_cs":"Střídavá napětí","search_cs":"Analogové měřiče napětí Digitální měřiče napětí Multimetry Kalibrace — Střídavá napětí Vnitřní postup; Ve stálé lokalitě (S) Střídavá napětí Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 499 Hz 40 Hz až 499 Hz 40 Hz až 499 Hz 40 Hz až 499 Hz 40 Hz až 499 Hz 499 Hz až 4999 Hz 499 Hz až 4999 Hz 499 Hz až 4999 Hz MW-AL-01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče napětí\nDigitální měřiče napětí\nMultimetry"},{"_id":"fe21f4970b195fb00f3cd195","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Kalibratory\nZasilacze","test_object_en":"Calibrators\nPower supplies","methodology":"Wzorcowanie — Napięcia AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"40 Hz do 100 Hz","range":"1 kV do 5 kV","cmc":"0,46 %"},{"name":"10 Hz do 20 kHz","range":"10 mV do 100 mV","cmc":"0,10 %"},{"name":"10 Hz do 20 kHz","range":"100 mV do 100 V","cmc":"0,09 %"},{"name":"10 Hz do 20 kHz","range":"100 V do 750 V","cmc":"0,10 %"},{"name":"20 kHz do 50 kHz","range":"10 mV do 100 mV","cmc":"0,15 %"},{"name":"20 kHz do 50 kHz","range":"100 mV do 1 V","cmc":"0,14 %"},{"name":"20 kHz do 50 kHz","range":"1 V do 100 V","cmc":"0,13 %"},{"name":"20 kHz do 50 kHz","range":"100 V do 750 V","cmc":"0,20 %"},{"name":"50 kHz do 100 kHz","range":"10 mV do 100 mV","cmc":"0,24 %"},{"name":"50 kHz do 100 kHz","range":"100 mV do 100 V","cmc":"0,23 %"},{"name":"50 kHz do 100 kHz","range":"100 V do 750 V","cmc":"0,29 %"},{"name":"100 kHz do 300 kHz","range":"10 mV do 100 mV","cmc":"1,3 %"},{"name":"100 kHz do 300 kHz","range":"100 mV do 10 V","cmc":"1,3 %"},{"name":"100 kHz do 300 kHz","range":"10 V do 100 V","cmc":"1,3 %"},{"name":"100 kHz do 300 kHz","range":"100 V do 750 V","cmc":"1,3 %"}],"parameters_en":[{"name":"40 Hz to 100 Hz","range":"1 kV to 5 kV","cmc":"0,46 %"},{"name":"10 Hz to 20 kHz","range":"10 mV to 100 mV","cmc":"0,10 %"},{"name":"10 Hz to 20 kHz","range":"100 mV to 100 V","cmc":"0,09 %"},{"name":"10 Hz to 20 kHz","range":"100 V to 750 V","cmc":"0,10 %"},{"name":"20 kHz to 50 kHz","range":"10 mV to 100 mV","cmc":"0,15 %"},{"name":"20 kHz to 50 kHz","range":"100 mV to 1 V","cmc":"0,14 %"},{"name":"20 kHz to 50 kHz","range":"1 V to 100 V","cmc":"0,13 %"},{"name":"20 kHz to 50 kHz","range":"100 V to 750 V","cmc":"0,20 %"},{"name":"50 kHz to 100 kHz","range":"10 mV to 100 mV","cmc":"0,24 %"},{"name":"50 kHz to 100 kHz","range":"100 mV to 100 V","cmc":"0,23 %"},{"name":"50 kHz to 100 kHz","range":"100 V to 750 V","cmc":"0,29 %"},{"name":"100 kHz to 300 kHz","range":"10 mV to 100 mV","cmc":"1,3 %"},{"name":"100 kHz to 300 kHz","range":"100 mV to 10 V","cmc":"1,3 %"},{"name":"100 kHz to 300 kHz","range":"10 V to 100 V","cmc":"1,3 %"},{"name":"100 kHz to 300 kHz","range":"100 V to 750 V","cmc":"1,3 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcia AC\nZakres:\n40 Hz do 100 Hz 1 kV do 5 kV CMC 0,46 %\n10 Hz do 20 kHz 10 mV do 100 mV CMC 0,10 %\n10 Hz do 20 kHz 100 mV do 100 V CMC 0,09 %\n10 Hz do 20 kHz 100 V do 750 V CMC 0,10 %\n20 kHz do 50 kHz 10 mV do 100 mV CMC 0,15 %\n20 kHz do 50 kHz 100 mV do 1 V CMC 0,14 %\n20 kHz do 50 kHz 1 V do 100 V CMC 0,13 %\n20 kHz do 50 kHz 100 V do 750 V CMC 0,20 %\n50 kHz do 100 kHz 10 mV do 100 mV CMC 0,24 %\n50 kHz do 100 kHz 100 mV do 100 V CMC 0,23 %\n50 kHz do 100 kHz 100 V do 750 V CMC 0,29 %\n100 kHz do 300 kHz 10 mV do 100 mV CMC 1,3 %\n100 kHz do 300 kHz 100 mV do 10 V CMC 1,3 %\n100 kHz do 300 kHz 10 V do 100 V CMC 1,3 %\n100 kHz do 300 kHz 100 V do 750 V CMC 1,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-02","norm_bases":["MW-AL-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcia AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory\nZasilacze Wzorcowanie — Napięcia AC\nZakres:\n40 Hz do 100 Hz 1 kV do 5 kV CMC 0,46 %\n10 Hz do 20 kHz 10 mV do 100 mV CMC 0,10 %\n10 Hz do 20 kHz 100 mV do 100 V CMC 0,09 %\n10 Hz do 20 kHz 100 V do 750 V CMC 0,10 %\n20 kHz do 50 kHz 10 mV do 100 mV CMC 0,15 %\n20 kHz do 50 kHz 100 mV do 1 V CMC 0,14 %\n20 kHz do 50 kHz 1 V do 100 V CMC 0,13 %\n20 kHz do 50 kHz 100 V do 750 V CMC 0,20 %\n50 kHz do 100 kHz 10 mV do 100 mV CMC 0,24 %\n50 kHz do 100 kHz 100 mV do 100 V CMC 0,23 %\n50 kHz do 100 kHz 100 V do 750 V CMC 0,29 %\n100 kHz do 300 kHz 10 mV do 100 mV CMC 1,3 %\n100 kHz do 300 kHz 100 mV do 10 V CMC 1,3 %\n100 kHz do 300 kHz 10 V do 100 V CMC 1,3 %\n100 kHz do 300 kHz 100 V do 750 V CMC 1,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-02 Kalibratory\nZasilacze Wzorcowanie — Napiecia AC\nZakres:\n40 Hz do 100 Hz 1 kV do 5 kV CMC 0,46 %\n10 Hz do 20 kHz 10 mV do 100 mV CMC 0,10 %\n10 Hz do 20 kHz 100 mV do 100 V CMC 0,09 %\n10 Hz do 20 kHz 100 V do 750 V CMC 0,10 %\n20 kHz do 50 kHz 10 mV do 100 mV CMC 0,15 %\n20 kHz do 50 kHz 100 mV do 1 V CMC 0,14 %\n20 kHz do 50 kHz 1 V do 100 V CMC 0,13 %\n20 kHz do 50 kHz 100 V do 750 V CMC 0,20 %\n50 kHz do 100 kHz 10 mV do 100 mV CMC 0,24 %\n50 kHz do 100 kHz 100 mV do 100 V CMC 0,23 %\n50 kHz do 100 kHz 100 V do 750 V CMC 0,29 %\n100 kHz do 300 kHz 10 mV do 100 mV CMC 1,3 %\n100 kHz do 300 kHz 100 mV do 10 V CMC 1,3 %\n100 kHz do 300 kHz 10 V do 100 V CMC 1,3 %\n100 kHz do 300 kHz 100 V do 750 V CMC 1,3 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-02","search_en":"Calibrators Power supplies Calibration — AC voltage Internal procedure; At permanent location (S) AC voltage Internal procedure At permanent location (S) 40 Hz to 100 Hz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 50 kHz to 100 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz 100 kHz to 300 kHz MW-AL-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselspannungen","parameters_de":[{"name":"40 Hz bis 100 Hz","range":"1 kV bis 5 kV","cmc":"0,46 %"},{"name":"10 Hz bis 20 kHz","range":"10 mV to 100 mV","cmc":"0,10 %"},{"name":"10 Hz bis 20 kHz","range":"100 mV to 100 V","cmc":"0,09 %"},{"name":"10 Hz bis 20 kHz","range":"100 V to 750 V","cmc":"0,10 %"},{"name":"20 kHz bis 50 kHz","range":"10 mV to 100 mV","cmc":"0,15 %"},{"name":"20 kHz bis 50 kHz","range":"100 mV to 1 V","cmc":"0,14 %"},{"name":"20 kHz bis 50 kHz","range":"1 V to 100 V","cmc":"0,13 %"},{"name":"20 kHz bis 50 kHz","range":"100 V to 750 V","cmc":"0,20 %"},{"name":"50 kHz bis 100 kHz","range":"10 mV to 100 mV","cmc":"0,24 %"},{"name":"50 kHz bis 100 kHz","range":"100 mV to 100 V","cmc":"0,23 %"},{"name":"50 kHz bis 100 kHz","range":"100 V to 750 V","cmc":"0,29 %"},{"name":"100 kHz bis 300 kHz","range":"10 mV to 100 mV","cmc":"1,3 %"},{"name":"100 kHz bis 300 kHz","range":"100 mV bis 10 V","cmc":"1,3 %"},{"name":"100 kHz bis 300 kHz","range":"10 V to 100 V","cmc":"1,3 %"},{"name":"100 kHz bis 300 kHz","range":"100 V to 750 V","cmc":"1,3 %"}],"regulatory_area_de":"Wechselspannungen","search_de":"Kalibratoren Netzgeräte Kalibrierung — Wechselspannungen Internes Verfahren; Am festen Standort (S) Wechselspannungen Internes Verfahren Am festen Standort (S) 40 Hz bis 100 Hz 10 Hz bis 20 kHz 10 Hz bis 20 kHz 10 Hz bis 20 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 20 kHz bis 50 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 50 kHz bis 100 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz 100 kHz bis 300 kHz MW-AL-02","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren\nNetzgeräte","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"40 Hz 至 100 Hz","range":"1 kV to 5 kV","cmc":"0,46 %"},{"name":"10 Hz 至 20 kHz","range":"10 mV to 100 mV","cmc":"0,10 %"},{"name":"10 Hz 至 20 kHz","range":"100 mV to 100 V","cmc":"0,09 %"},{"name":"10 Hz 至 20 kHz","range":"100 V to 750 V","cmc":"0,10 %"},{"name":"20 kHz 至 50 kHz","range":"10 mV to 100 mV","cmc":"0,15 %"},{"name":"20 kHz 至 50 kHz","range":"100 mV to 1 V","cmc":"0,14 %"},{"name":"20 kHz 至 50 kHz","range":"1 V to 100 V","cmc":"0,13 %"},{"name":"20 kHz 至 50 kHz","range":"100 V to 750 V","cmc":"0,20 %"},{"name":"50 kHz 至 100 kHz","range":"10 mV to 100 mV","cmc":"0,24 %"},{"name":"50 kHz 至 100 kHz","range":"100 mV to 100 V","cmc":"0,23 %"},{"name":"50 kHz 至 100 kHz","range":"100 V to 750 V","cmc":"0,29 %"},{"name":"100 kHz 至 300 kHz","range":"10 mV to 100 mV","cmc":"1,3 %"},{"name":"100 kHz 至 300 kHz","range":"100 mV to 10 V","cmc":"1,3 %"},{"name":"100 kHz 至 300 kHz","range":"10 V to 100 V","cmc":"1,3 %"},{"name":"100 kHz 至 300 kHz","range":"100 V to 750 V","cmc":"1,3 %"}],"regulatory_area_zh":"交流电压","search_zh":"校准器 电源 校准 — 交流电压 内部程序；在固定地点 (S) 交流电压 内部程序 在固定地点 (S) 40 Hz 至 100 Hz 10 Hz 至 20 kHz 10 Hz 至 20 kHz 10 Hz 至 20 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 20 kHz 至 50 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 50 kHz 至 100 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz 100 kHz 至 300 kHz MW-AL-02","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器\n电源","methodology_cs":"Kalibrace — Střídavá napětí","parameters_cs":[{"name":"40 Hz až 100 Hz","range":"1 kV to 5 kV","cmc":"0,46 %"},{"name":"10 Hz až 20 kHz","range":"10 mV to 100 mV","cmc":"0,10 %"},{"name":"10 Hz až 20 kHz","range":"100 mV to 100 V","cmc":"0,09 %"},{"name":"10 Hz až 20 kHz","range":"100 V to 750 V","cmc":"0,10 %"},{"name":"20 kHz až 50 kHz","range":"10 mV to 100 mV","cmc":"0,15 %"},{"name":"20 kHz až 50 kHz","range":"100 mV to 1 V","cmc":"0,14 %"},{"name":"20 kHz až 50 kHz","range":"1 V to 100 V","cmc":"0,13 %"},{"name":"20 kHz až 50 kHz","range":"100 V to 750 V","cmc":"0,20 %"},{"name":"50 kHz až 100 kHz","range":"10 mV to 100 mV","cmc":"0,24 %"},{"name":"50 kHz až 100 kHz","range":"100 mV to 100 V","cmc":"0,23 %"},{"name":"50 kHz až 100 kHz","range":"100 V to 750 V","cmc":"0,29 %"},{"name":"100 kHz až 300 kHz","range":"10 mV to 100 mV","cmc":"1,3 %"},{"name":"100 kHz až 300 kHz","range":"100 mV to 10 V","cmc":"1,3 %"},{"name":"100 kHz až 300 kHz","range":"10 V to 100 V","cmc":"1,3 %"},{"name":"100 kHz až 300 kHz","range":"100 V to 750 V","cmc":"1,3 %"}],"regulatory_area_cs":"Střídavá napětí","search_cs":"Kalibrátory Napájecí zdroje Kalibrace — Střídavá napětí Vnitřní postup; Ve stálé lokalitě (S) Střídavá napětí Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 100 Hz 10 Hz až 20 kHz 10 Hz až 20 kHz 10 Hz až 20 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 20 kHz až 50 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 50 kHz až 100 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz 100 kHz až 300 kHz MW-AL-02","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory\nNapájecí zdroje"},{"_id":"b295dd2740be37fa853695ab","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Mierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry","test_object_en":"Analogue ammeters\nDigital ammeters\nMultimeters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"40 Hz do 499 Hz","range":"0,1 mA do 1 mA","cmc":"0,35 %"},{"name":"40 Hz do 499 Hz","range":"1 mA do 10 mA","cmc":"0,21 %"},{"name":"40 Hz do 499 Hz","range":"10 mA do 100 mA","cmc":"0,20 %"},{"name":"40 Hz do 499 Hz","range":"100 mA do 1 A","cmc":"0,21 %"},{"name":"40 Hz do 499 Hz","range":"1 A do 10 A","cmc":"0,46 %"},{"name":"499 Hz do 1999 Hz","range":"0,1 mA do 1 mA","cmc":"0,61 %"},{"name":"1999 Hz do 4999 Hz","range":"0,1 mA do 1 mA","cmc":"1,8 %"},{"name":"499 Hz do 4999 Hz","range":"1 mA do 10 mA","cmc":"0,26 %"},{"name":"499 Hz do 4999 Hz","range":"10 mA do 100 mA","cmc":"0,24 %"},{"name":"499 Hz do 4999 Hz","range":"100 mA do 1 A","cmc":"0,24 %"},{"name":"499 Hz do 4999 Hz","range":"1 A do 10 A","cmc":"0,48 %"}],"parameters_en":[{"name":"40 Hz to 499 Hz","range":"0,1 mA to 1 mA","cmc":"0,35 %"},{"name":"40 Hz to 499 Hz","range":"1 mA to 10 mA","cmc":"0,21 %"},{"name":"40 Hz to 499 Hz","range":"10 mA to 100 mA","cmc":"0,20 %"},{"name":"40 Hz to 499 Hz","range":"100 mA to 1 A","cmc":"0,21 %"},{"name":"40 Hz to 499 Hz","range":"1 A to 10 A","cmc":"0,46 %"},{"name":"499 Hz to 1999 Hz","range":"0,1 mA to 1 mA","cmc":"0,61 %"},{"name":"1999 Hz to 4999 Hz","range":"0,1 mA to 1 mA","cmc":"1,8 %"},{"name":"499 Hz to 4999 Hz","range":"1 mA to 10 mA","cmc":"0,26 %"},{"name":"499 Hz to 4999 Hz","range":"10 mA to 100 mA","cmc":"0,24 %"},{"name":"499 Hz to 4999 Hz","range":"100 mA to 1 A","cmc":"0,24 %"},{"name":"499 Hz to 4999 Hz","range":"1 A to 10 A","cmc":"0,48 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 499 Hz 0,1 mA do 1 mA CMC 0,35 %\n40 Hz do 499 Hz 1 mA do 10 mA CMC 0,21 %\n40 Hz do 499 Hz 10 mA do 100 mA CMC 0,20 %\n40 Hz do 499 Hz 100 mA do 1 A CMC 0,21 %\n40 Hz do 499 Hz 1 A do 10 A CMC 0,46 %\n499 Hz do 1999 Hz 0,1 mA do 1 mA CMC 0,61 %\n1999 Hz do 4999 Hz 0,1 mA do 1 mA CMC 1,8 %\n499 Hz do 4999 Hz 1 mA do 10 mA CMC 0,26 %\n499 Hz do 4999 Hz 10 mA do 100 mA CMC 0,24 %\n499 Hz do 4999 Hz 100 mA do 1 A CMC 0,24 %\n499 Hz do 4999 Hz 1 A do 10 A CMC 0,48 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-01","norm_bases":["MW-AL-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry Wzorcowanie — Prąd AC\nZakres:\n40 Hz do 499 Hz 0,1 mA do 1 mA CMC 0,35 %\n40 Hz do 499 Hz 1 mA do 10 mA CMC 0,21 %\n40 Hz do 499 Hz 10 mA do 100 mA CMC 0,20 %\n40 Hz do 499 Hz 100 mA do 1 A CMC 0,21 %\n40 Hz do 499 Hz 1 A do 10 A CMC 0,46 %\n499 Hz do 1999 Hz 0,1 mA do 1 mA CMC 0,61 %\n1999 Hz do 4999 Hz 0,1 mA do 1 mA CMC 1,8 %\n499 Hz do 4999 Hz 1 mA do 10 mA CMC 0,26 %\n499 Hz do 4999 Hz 10 mA do 100 mA CMC 0,24 %\n499 Hz do 4999 Hz 100 mA do 1 A CMC 0,24 %\n499 Hz do 4999 Hz 1 A do 10 A CMC 0,48 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-01 Mierniki pradu analogowe\nMierniki pradu cyfrowe\nMultimetry Wzorcowanie — Prad AC\nZakres:\n40 Hz do 499 Hz 0,1 mA do 1 mA CMC 0,35 %\n40 Hz do 499 Hz 1 mA do 10 mA CMC 0,21 %\n40 Hz do 499 Hz 10 mA do 100 mA CMC 0,20 %\n40 Hz do 499 Hz 100 mA do 1 A CMC 0,21 %\n40 Hz do 499 Hz 1 A do 10 A CMC 0,46 %\n499 Hz do 1999 Hz 0,1 mA do 1 mA CMC 0,61 %\n1999 Hz do 4999 Hz 0,1 mA do 1 mA CMC 1,8 %\n499 Hz do 4999 Hz 1 mA do 10 mA CMC 0,26 %\n499 Hz do 4999 Hz 10 mA do 100 mA CMC 0,24 %\n499 Hz do 4999 Hz 100 mA do 1 A CMC 0,24 %\n499 Hz do 4999 Hz 1 A do 10 A CMC 0,48 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-01","search_en":"Analogue ammeters Digital ammeters Multimeters Calibration — AC current Internal procedure; At permanent location (S) AC current Internal procedure At permanent location (S) 40 Hz to 499 Hz 40 Hz to 499 Hz 40 Hz to 499 Hz 40 Hz to 499 Hz 40 Hz to 499 Hz 499 Hz to 1999 Hz 1999 Hz to 4999 Hz 499 Hz to 4999 Hz 499 Hz to 4999 Hz 499 Hz to 4999 Hz 499 Hz to 4999 Hz MW-AL-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"40 Hz bis 499 Hz","range":"0,1 mA to 1 mA","cmc":"0,35 %"},{"name":"40 Hz bis 499 Hz","range":"1 mA to 10 mA","cmc":"0,21 %"},{"name":"40 Hz bis 499 Hz","range":"10 mA bis 100 mA","cmc":"0,20 %"},{"name":"40 Hz bis 499 Hz","range":"100 mA to 1 A","cmc":"0,21 %"},{"name":"40 Hz bis 499 Hz","range":"1 A to 10 A","cmc":"0,46 %"},{"name":"499 Hz bis 1999 Hz","range":"0,1 mA to 1 mA","cmc":"0,61 %"},{"name":"1999 Hz bis 4999 Hz","range":"0,1 mA to 1 mA","cmc":"1,8 %"},{"name":"499 Hz bis 4999 Hz","range":"1 mA to 10 mA","cmc":"0,26 %"},{"name":"499 Hz bis 4999 Hz","range":"10 mA bis 100 mA","cmc":"0,24 %"},{"name":"499 Hz bis 4999 Hz","range":"100 mA to 1 A","cmc":"0,24 %"},{"name":"499 Hz bis 4999 Hz","range":"1 A to 10 A","cmc":"0,48 %"}],"regulatory_area_de":"AC-Strom","search_de":"Analoge Strommessgeräte Digitale Strommessgeräte Multimeter Kalibrierung — Wechselstrom Internes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Am festen Standort (S) 40 Hz bis 499 Hz 40 Hz bis 499 Hz 40 Hz bis 499 Hz 40 Hz bis 499 Hz 40 Hz bis 499 Hz 499 Hz bis 1999 Hz 1999 Hz bis 4999 Hz 499 Hz bis 4999 Hz 499 Hz bis 4999 Hz 499 Hz bis 4999 Hz 499 Hz bis 4999 Hz MW-AL-01","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Strommessgeräte\nDigitale Strommessgeräte\nMultimeter","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"40 Hz 至 499 Hz","range":"0,1 mA to 1 mA","cmc":"0,35 %"},{"name":"40 Hz 至 499 Hz","range":"1 mA to 10 mA","cmc":"0,21 %"},{"name":"40 Hz 至 499 Hz","range":"10 mA to 100 mA","cmc":"0,20 %"},{"name":"40 Hz 至 499 Hz","range":"100 mA to 1 A","cmc":"0,21 %"},{"name":"40 Hz 至 499 Hz","range":"1 A to 10 A","cmc":"0,46 %"},{"name":"499 Hz 至 1999 Hz","range":"0,1 mA to 1 mA","cmc":"0,61 %"},{"name":"1999 Hz 至 4999 Hz","range":"0,1 mA to 1 mA","cmc":"1,8 %"},{"name":"499 Hz 至 4999 Hz","range":"1 mA to 10 mA","cmc":"0,26 %"},{"name":"499 Hz 至 4999 Hz","range":"10 mA to 100 mA","cmc":"0,24 %"},{"name":"499 Hz 至 4999 Hz","range":"100 mA to 1 A","cmc":"0,24 %"},{"name":"499 Hz 至 4999 Hz","range":"1 A to 10 A","cmc":"0,48 %"}],"regulatory_area_zh":"交流电流","search_zh":"模拟电流表 数字电流表 万用表 校准 — 交流电流 内部程序；在固定地点 (S) 交流电流 内部程序 在固定地点 (S) 40 Hz 至 499 Hz 40 Hz 至 499 Hz 40 Hz 至 499 Hz 40 Hz 至 499 Hz 40 Hz 至 499 Hz 499 Hz 至 1999 Hz 1999 Hz 至 4999 Hz 499 Hz 至 4999 Hz 499 Hz 至 4999 Hz 499 Hz 至 4999 Hz 499 Hz 至 4999 Hz MW-AL-01","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"模拟电流表\n数字电流表\n万用表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"40 Hz až 499 Hz","range":"0,1 mA to 1 mA","cmc":"0,35 %"},{"name":"40 Hz až 499 Hz","range":"1 mA to 10 mA","cmc":"0,21 %"},{"name":"40 Hz až 499 Hz","range":"10 mA to 100 mA","cmc":"0,20 %"},{"name":"40 Hz až 499 Hz","range":"100 mA to 1 A","cmc":"0,21 %"},{"name":"40 Hz až 499 Hz","range":"1 A to 10 A","cmc":"0,46 %"},{"name":"499 Hz až 1999 Hz","range":"0,1 mA to 1 mA","cmc":"0,61 %"},{"name":"1999 Hz až 4999 Hz","range":"0,1 mA to 1 mA","cmc":"1,8 %"},{"name":"499 Hz až 4999 Hz","range":"1 mA to 10 mA","cmc":"0,26 %"},{"name":"499 Hz až 4999 Hz","range":"10 mA to 100 mA","cmc":"0,24 %"},{"name":"499 Hz až 4999 Hz","range":"100 mA to 1 A","cmc":"0,24 %"},{"name":"499 Hz až 4999 Hz","range":"1 A to 10 A","cmc":"0,48 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Analogové měřiče proudu Digitální měřiče proudu Multimetry Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) Proud AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 499 Hz 40 Hz až 499 Hz 40 Hz až 499 Hz 40 Hz až 499 Hz 40 Hz až 499 Hz 499 Hz až 1999 Hz 1999 Hz až 4999 Hz 499 Hz až 4999 Hz 499 Hz až 4999 Hz 499 Hz až 4999 Hz 499 Hz až 4999 Hz MW-AL-01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče proudu\nDigitální měřiče proudu\nMultimetry"},{"_id":"64310b8ebd127da41a4067e6","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Mierniki cęgowe","test_object_en":"Clamp meters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"40 Hz do 100 Hz","range":"10 A do 200 A","cmc":"0,46 %"}],"parameters_en":[{"name":"40 Hz to 100 Hz","range":"10 A to 200 A","cmc":"0,46 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\n40 Hz do 100 Hz 10 A do 200 A CMC 0,46 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-03","norm_bases":["MW-AL-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki cęgowe Wzorcowanie — Prąd AC\n40 Hz do 100 Hz 10 A do 200 A CMC 0,46 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-03 Mierniki cegowe Wzorcowanie — Prad AC\n40 Hz do 100 Hz 10 A do 200 A CMC 0,46 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-03","search_en":"Clamp meters Calibration — AC current Internal procedure; At permanent location (S) AC current Internal procedure At permanent location (S) 40 Hz to 100 Hz MW-AL-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"40 Hz bis 100 Hz","range":"10 A to 200 A","cmc":"0,46 %"}],"regulatory_area_de":"AC-Strom","search_de":"Zangenmessgeräte Kalibrierung — Wechselstrom Internes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Am festen Standort (S) 40 Hz bis 100 Hz MW-AL-03","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Zangenmessgeräte","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"40 Hz 至 100 Hz","range":"10 A to 200 A","cmc":"0,46 %"}],"regulatory_area_zh":"交流电流","search_zh":"钳形表 校准 — 交流电流 内部程序；在固定地点 (S) 交流电流 内部程序 在固定地点 (S) 40 Hz 至 100 Hz MW-AL-03","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"钳形表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"40 Hz až 100 Hz","range":"10 A to 200 A","cmc":"0,46 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Klešťové měřiče Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) Proud AC Vnitřní postup Ve stálé lokalitě (S) 40 Hz až 100 Hz MW-AL-03","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Klešťové měřiče"},{"_id":"682af9f6e140277092bc6d1e","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Kalibratory","test_object_en":"Calibrators","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"3 Hz do 10000 Hz","range":"0,1 mA do 100 mA","cmc":"0,18 %"},{"name":"3 Hz do 10000 Hz","range":"100 mA do 1 A","cmc":"0,19 %"},{"name":"3 Hz do 10000 Hz","range":"1 A do 3 A","cmc":"0,43 %"},{"name":"3 Hz do 10000 Hz","range":"3 A do 5 A","cmc":"0,39 %"},{"name":"3 Hz do 10000 Hz","range":"5 A do 10 A","cmc":"0,45 %"}],"parameters_en":[{"name":"3 Hz to 10000 Hz","range":"0,1 mA to 100 mA","cmc":"0,18 %"},{"name":"3 Hz to 10000 Hz","range":"100 mA to 1 A","cmc":"0,19 %"},{"name":"3 Hz to 10000 Hz","range":"1 A to 3 A","cmc":"0,43 %"},{"name":"3 Hz to 10000 Hz","range":"3 A to 5 A","cmc":"0,39 %"},{"name":"3 Hz to 10000 Hz","range":"5 A to 10 A","cmc":"0,45 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n3 Hz do 10000 Hz 0,1 mA do 100 mA CMC 0,18 %\n3 Hz do 10000 Hz 100 mA do 1 A CMC 0,19 %\n3 Hz do 10000 Hz 1 A do 3 A CMC 0,43 %\n3 Hz do 10000 Hz 3 A do 5 A CMC 0,39 %\n3 Hz do 10000 Hz 5 A do 10 A CMC 0,45 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-02","norm_bases":["MW-AL-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory Wzorcowanie — Prąd AC\nZakres:\n3 Hz do 10000 Hz 0,1 mA do 100 mA CMC 0,18 %\n3 Hz do 10000 Hz 100 mA do 1 A CMC 0,19 %\n3 Hz do 10000 Hz 1 A do 3 A CMC 0,43 %\n3 Hz do 10000 Hz 3 A do 5 A CMC 0,39 %\n3 Hz do 10000 Hz 5 A do 10 A CMC 0,45 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-02 Kalibratory Wzorcowanie — Prad AC\nZakres:\n3 Hz do 10000 Hz 0,1 mA do 100 mA CMC 0,18 %\n3 Hz do 10000 Hz 100 mA do 1 A CMC 0,19 %\n3 Hz do 10000 Hz 1 A do 3 A CMC 0,43 %\n3 Hz do 10000 Hz 3 A do 5 A CMC 0,39 %\n3 Hz do 10000 Hz 5 A do 10 A CMC 0,45 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-02","search_en":"Calibrators Calibration — AC current Internal procedure; At permanent location (S) AC current Internal procedure At permanent location (S) 3 Hz to 10000 Hz 3 Hz to 10000 Hz 3 Hz to 10000 Hz 3 Hz to 10000 Hz 3 Hz to 10000 Hz MW-AL-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"3 Hz bis 10000 Hz","range":"0,1 mA to 100 mA","cmc":"0,18 %"},{"name":"3 Hz bis 10000 Hz","range":"100 mA to 1 A","cmc":"0,19 %"},{"name":"3 Hz bis 10000 Hz","range":"1 A to 3 A","cmc":"0,43 %"},{"name":"3 Hz bis 10000 Hz","range":"3 A to 5 A","cmc":"0,39 %"},{"name":"3 Hz bis 10000 Hz","range":"5 A to 10 A","cmc":"0,45 %"}],"regulatory_area_de":"AC-Strom","search_de":"Kalibratoren Kalibrierung — Wechselstrom Internes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Am festen Standort (S) 3 Hz bis 10000 Hz 3 Hz bis 10000 Hz 3 Hz bis 10000 Hz 3 Hz bis 10000 Hz 3 Hz bis 10000 Hz MW-AL-02","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Kalibratoren","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"3 Hz 至 10000 Hz","range":"0,1 mA to 100 mA","cmc":"0,18 %"},{"name":"3 Hz 至 10000 Hz","range":"100 mA to 1 A","cmc":"0,19 %"},{"name":"3 Hz 至 10000 Hz","range":"1 A to 3 A","cmc":"0,43 %"},{"name":"3 Hz 至 10000 Hz","range":"3 A to 5 A","cmc":"0,39 %"},{"name":"3 Hz 至 10000 Hz","range":"5 A to 10 A","cmc":"0,45 %"}],"regulatory_area_zh":"交流电流","search_zh":"校准器 校准 — 交流电流 内部程序；在固定地点 (S) 交流电流 内部程序 在固定地点 (S) 3 Hz 至 10000 Hz 3 Hz 至 10000 Hz 3 Hz 至 10000 Hz 3 Hz 至 10000 Hz 3 Hz 至 10000 Hz MW-AL-02","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"校准器","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"3 Hz až 10000 Hz","range":"0,1 mA to 100 mA","cmc":"0,18 %"},{"name":"3 Hz až 10000 Hz","range":"100 mA to 1 A","cmc":"0,19 %"},{"name":"3 Hz až 10000 Hz","range":"1 A to 3 A","cmc":"0,43 %"},{"name":"3 Hz až 10000 Hz","range":"3 A to 5 A","cmc":"0,39 %"},{"name":"3 Hz až 10000 Hz","range":"5 A to 10 A","cmc":"0,45 %"}],"regulatory_area_cs":"Proud AC","search_cs":"Kalibrátory Kalibrace — Proud AC Vnitřní postup; Ve stálé lokalitě (S) Proud AC Vnitřní postup Ve stálé lokalitě (S) 3 Hz až 10000 Hz 3 Hz až 10000 Hz 3 Hz až 10000 Hz 3 Hz až 10000 Hz 3 Hz až 10000 Hz MW-AL-02","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory"},{"_id":"1e7d7efa1fc88f174e59ee3b","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Rezystory stałe\nRezystory regulowane","test_object_en":"Fixed resistors\nVariable resistors","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0 Ω do 100 Ω","cmc":"0,013 %"},{"name":"","range":"100 Ω do 1 kΩ","cmc":"0,0066 %"},{"name":"","range":"1 kΩ do 10 kΩ","cmc":"0,0065 %"},{"name":"","range":"10 kΩ do 100 kΩ","cmc":"0,0066 %"},{"name":"","range":"100 kΩ do 1 MΩ","cmc":"0,010 %"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,037 %"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,46 %"},{"name":"","range":"100 MΩ do 1000 MΩ","cmc":"4,6 %"}],"parameters_en":[{"name":"","range":"0 Ω to 100 Ω","cmc":"0,013 %"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0066 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0065 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0066 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,010 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,037 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,46 %"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"4,6 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω do 100 Ω CMC 0,013 %\n100 Ω do 1 kΩ CMC 0,0066 %\n1 kΩ do 10 kΩ CMC 0,0065 %\n10 kΩ do 100 kΩ CMC 0,0066 %\n100 kΩ do 1 MΩ CMC 0,010 %\n1 MΩ do 10 MΩ CMC 0,037 %\n10 MΩ do 100 MΩ CMC 0,46 %\n100 MΩ do 1000 MΩ CMC 4,6 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-05","norm_bases":["MW-AL-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Rezystory stałe\nRezystory regulowane Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω do 100 Ω CMC 0,013 %\n100 Ω do 1 kΩ CMC 0,0066 %\n1 kΩ do 10 kΩ CMC 0,0065 %\n10 kΩ do 100 kΩ CMC 0,0066 %\n100 kΩ do 1 MΩ CMC 0,010 %\n1 MΩ do 10 MΩ CMC 0,037 %\n10 MΩ do 100 MΩ CMC 0,46 %\n100 MΩ do 1000 MΩ CMC 4,6 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-05 Rezystory stale\nRezystory regulowane Wzorcowanie — Rezystancja DC\nZakres:\n0 Ω do 100 Ω CMC 0,013 %\n100 Ω do 1 kΩ CMC 0,0066 %\n1 kΩ do 10 kΩ CMC 0,0065 %\n10 kΩ do 100 kΩ CMC 0,0066 %\n100 kΩ do 1 MΩ CMC 0,010 %\n1 MΩ do 10 MΩ CMC 0,037 %\n10 MΩ do 100 MΩ CMC 0,46 %\n100 MΩ do 1000 MΩ CMC 4,6 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-05","search_en":"Fixed resistors Variable resistors Calibration — DC resistance Internal procedure; At permanent location (S) DC resistance Internal procedure At permanent location (S) MW-AL-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0 Ω to 100 Ω","cmc":"0,013 %"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0066 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0065 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0066 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,010 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,037 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,46 %"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"4,6 %"}],"regulatory_area_de":"DC-Widerstand","search_de":"Festwiderstände Einstellbare Widerstände Kalibrierung — DC-Widerstand Internes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Am festen Standort (S) MW-AL-05","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Festwiderstände\nEinstellbare Widerstände","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0 Ω to 100 Ω","cmc":"0,013 %"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0066 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0065 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0066 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,010 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,037 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,46 %"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"4,6 %"}],"regulatory_area_zh":"直流电阻","search_zh":"固定电阻器 可调电阻器 校准 — 直流电阻 内部程序；在固定地点 (S) 直流电阻 内部程序 在固定地点 (S) MW-AL-05","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"固定电阻器\n可调电阻器","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0 Ω to 100 Ω","cmc":"0,013 %"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,0066 %"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"0,0065 %"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"0,0066 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,010 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,037 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,46 %"},{"name":"","range":"100 MΩ to 1000 MΩ","cmc":"4,6 %"}],"regulatory_area_cs":"Odpor DC","search_cs":"Pevné rezistory Nastavitelné rezistory Kalibrace — Odpor DC Vnitřní postup; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Ve stálé lokalitě (S) MW-AL-05","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Pevné rezistory\nNastavitelné rezistory"},{"_id":"ec903bf2d7a8064871f3f38d","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMultimetry","test_object_en":"Analogue ohmmeters\nDigital ohmmeters\nMultimeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"1 Ω do 10 Ω","cmc":"0,1 %"},{"name":"","range":"10 Ω do 1 kΩ","cmc":"0,06 %"},{"name":"","range":"1 kΩ do 1 MΩ","cmc":"0,036 %"},{"name":"","range":"1 MΩ do 10 MΩ","cmc":"0,12 %"},{"name":"","range":"10 MΩ do 100 MΩ","cmc":"0,48 %"}],"parameters_en":[{"name":"","range":"1 Ω to 10 Ω","cmc":"0,1 %"},{"name":"","range":"10 Ω to 1 kΩ","cmc":"0,06 %"},{"name":"","range":"1 kΩ to 1 MΩ","cmc":"0,036 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,48 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n1 Ω do 10 Ω CMC 0,1 %\n10 Ω do 1 kΩ CMC 0,06 %\n1 kΩ do 1 MΩ CMC 0,036 %\n1 MΩ do 10 MΩ CMC 0,12 %\n10 MΩ do 100 MΩ CMC 0,48 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"MW-AL-04","norm_bases":["MW-AL-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n1 Ω do 10 Ω CMC 0,1 %\n10 Ω do 1 kΩ CMC 0,06 %\n1 kΩ do 1 MΩ CMC 0,036 %\n1 MΩ do 10 MΩ CMC 0,12 %\n10 MΩ do 100 MΩ CMC 0,48 %\nProcedura wewnętrzna; W stałej lokalizacji (S) MW-AL-04 Mierniki rezystancji analogowe\nMierniki rezystancji cyfrowe\nMultimetry Wzorcowanie — Rezystancja DC\nZakres:\n1 Ω do 10 Ω CMC 0,1 %\n10 Ω do 1 kΩ CMC 0,06 %\n1 kΩ do 1 MΩ CMC 0,036 %\n1 MΩ do 10 MΩ CMC 0,12 %\n10 MΩ do 100 MΩ CMC 0,48 %\nProcedura wewnetrzna; W stalej lokalizacji (S) MW-AL-04","search_en":"Analogue ohmmeters Digital ohmmeters Multimeters Calibration — DC resistance Internal procedure; At permanent location (S) DC resistance Internal procedure At permanent location (S) MW-AL-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"1 Ω to 10 Ω","cmc":"0,1 %"},{"name":"","range":"10 Ω to 1 kΩ","cmc":"0,06 %"},{"name":"","range":"1 kΩ to 1 MΩ","cmc":"0,036 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,48 %"}],"regulatory_area_de":"DC-Widerstand","search_de":"Analoge Widerstandsmessgeräte Digitale Widerstandsmessgeräte Multimeter Kalibrierung — DC-Widerstand Internes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Am festen Standort (S) MW-AL-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Widerstandsmessgeräte\nDigitale Widerstandsmessgeräte\nMultimeter","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"1 Ω to 10 Ω","cmc":"0,1 %"},{"name":"","range":"10 Ω to 1 kΩ","cmc":"0,06 %"},{"name":"","range":"1 kΩ to 1 MΩ","cmc":"0,036 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,48 %"}],"regulatory_area_zh":"直流电阻","search_zh":"模拟式电阻表 数字电阻测量仪 万用表 校准 — 直流电阻 内部程序；在固定地点 (S) 直流电阻 内部程序 在固定地点 (S) MW-AL-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"模拟式电阻表\n数字电阻测量仪\n万用表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"1 Ω to 10 Ω","cmc":"0,1 %"},{"name":"","range":"10 Ω to 1 kΩ","cmc":"0,06 %"},{"name":"","range":"1 kΩ to 1 MΩ","cmc":"0,036 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,12 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,48 %"}],"regulatory_area_cs":"Odpor DC","search_cs":"Analogové měřiče odporu Digitální měřiče odporu Multimetry Kalibrace — Odpor DC Vnitřní postup; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Ve stálé lokalitě (S) MW-AL-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče odporu\nDigitální měřiče odporu\nMultimetry"},{"_id":"524215e7c97b2e98ba538e91","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Generatory okresu","test_object_en":"Period generators","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"100 ns do 100 s","cmc":"20 uHz · T² + 9 · 10⁻¹⁰ · T"}],"parameters_en":[{"name":"","range":"100 ns to 100 s","cmc":"20 uHz · T² + 9 · 10⁻¹⁰ · T"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n100 ns do 100 s CMC 20 uHz · T² + 9 · 10⁻¹⁰ · T\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"MW-AL-06","norm_bases":["MW-AL-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"(składnik 20 uHz · T² dla przebiegów sinusoidalnych przy okresie T > 0,1 ms)\nT – wielkość mierzona (s)","note_en":"(the 20 uHz · T² term for sinusoidal waveforms with period T > 0,1 ms)\nT – measured quantity (s)","search_text":"Generatory okresu Wzorcowanie — Czas (przedział czasu)\n100 ns do 100 s CMC 20 uHz · T² + 9 · 10⁻¹⁰ · T\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) MW-AL-06 Generatory okresu Wzorcowanie — Czas (przedzial czasu)\n100 ns do 100 s CMC 20 uHz · T² + 9 · 10⁻¹⁰ · T\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) MW-AL-06","search_en":"Period generators Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) MW-AL-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"100 ns to 100 s","cmc":"20 uHz · T² + 9 · 10⁻¹⁰ · T"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Periodengeneratoren Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) MW-AL-06","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Periodengeneratoren","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"100 ns to 100 s","cmc":"20 uHz · T² + 9 · 10⁻¹⁰ · T"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"周期发生器 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) MW-AL-06","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"周期发生器","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"100 ns to 100 s","cmc":"20 uHz · T² + 9 · 10⁻¹⁰ · T"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Generátory periody Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) MW-AL-06","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Generátory periody"},{"_id":"0218c937d8ab8d6d51623f57","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Generatory przedziału czasu","test_object_en":"Time interval generators","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"100 ns do 1000 s","cmc":"0,9 ns + 9 · 10⁻¹⁰ · T"}],"parameters_en":[{"name":"","range":"100 ns to 1000 s","cmc":"0,9 ns + 9 · 10⁻¹⁰ · T"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n100 ns do 1000 s CMC 0,9 ns + 9 · 10⁻¹⁰ · T\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"MW-AL-06","norm_bases":["MW-AL-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"T – wielkość mierzona (s)","note_en":"T – measured quantity (s)","search_text":"Generatory przedziału czasu Wzorcowanie — Czas (przedział czasu)\n100 ns do 1000 s CMC 0,9 ns + 9 · 10⁻¹⁰ · T\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) MW-AL-06 Generatory przedzialu czasu Wzorcowanie — Czas (przedzial czasu)\n100 ns do 1000 s CMC 0,9 ns + 9 · 10⁻¹⁰ · T\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) MW-AL-06","search_en":"Time interval generators Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) MW-AL-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"100 ns to 1000 s","cmc":"0,9 ns + 9 · 10⁻¹⁰ · T"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Zeitintervallgeneratoren Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) MW-AL-06","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Zeitintervallgeneratoren","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"100 ns to 1000 s","cmc":"0,9 ns + 9 · 10⁻¹⁰ · T"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"时间间隔发生器 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) MW-AL-06","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"时间间隔发生器","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"100 ns to 1000 s","cmc":"0,9 ns + 9 · 10⁻¹⁰ · T"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Generátory časového intervalu Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) MW-AL-06","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Generátory časového intervalu"},{"_id":"a27ddc1340a251e3ba876d81","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Mierniki okresu","test_object_en":"Period meters","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"sygnał prostokątny","range":"100 ns do 25 s","cmc":"9 · 10⁻¹⁰ · T"}],"parameters_en":[{"name":"square-wave signal","range":"100 ns to 25 s","cmc":"9 · 10⁻¹⁰ · T"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nsygnał prostokątny 100 ns do 25 s CMC 9 · 10⁻¹⁰ · T\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"MW-AL-07","norm_bases":["MW-AL-07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"T – wielkość mierzona (s)","note_en":"T – measured quantity (s)","search_text":"Mierniki okresu Wzorcowanie — Czas (przedział czasu)\nsygnał prostokątny 100 ns do 25 s CMC 9 · 10⁻¹⁰ · T\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) MW-AL-07 Mierniki okresu Wzorcowanie — Czas (przedzial czasu)\nsygnal prostokatny 100 ns do 25 s CMC 9 · 10⁻¹⁰ · T\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) MW-AL-07","search_en":"Period meters Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) square-wave signal MW-AL-07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"Rechtecksignal","range":"100 ns to 25 s","cmc":"9 · 10⁻¹⁰ · T"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Periodendauermesser Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) Rechtecksignal MW-AL-07","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Periodendauermesser","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"方波信号","range":"100 ns to 25 s","cmc":"9 · 10⁻¹⁰ · T"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"周期测量仪 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) 方波信号 MW-AL-07","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"周期测量仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"obdélníkový signál","range":"100 ns to 25 s","cmc":"9 · 10⁻¹⁰ · T"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče periody Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) obdélníkový signál MW-AL-07","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče periody"},{"_id":"3c8bdec49be992d6c65d166c","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Mierniki przedziału czasu","test_object_en":"Time interval meters","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"100 ns do 1000 s","cmc":"1,4 ns + 9 · 10⁻¹⁰ · T"}],"parameters_en":[{"name":"","range":"100 ns to 1000 s","cmc":"1,4 ns + 9 · 10⁻¹⁰ · T"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n100 ns do 1000 s CMC 1,4 ns + 9 · 10⁻¹⁰ · T\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"MW-AL-07","norm_bases":["MW-AL-07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"T – wielkość mierzona (s)","note_en":"T – measured quantity (s)","search_text":"Mierniki przedziału czasu Wzorcowanie — Czas (przedział czasu)\n100 ns do 1000 s CMC 1,4 ns + 9 · 10⁻¹⁰ · T\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) MW-AL-07 Mierniki przedzialu czasu Wzorcowanie — Czas (przedzial czasu)\n100 ns do 1000 s CMC 1,4 ns + 9 · 10⁻¹⁰ · T\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) MW-AL-07","search_en":"Time interval meters Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) MW-AL-07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"100 ns to 1000 s","cmc":"1,4 ns + 9 · 10⁻¹⁰ · T"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Zeitintervallmessgeräte Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) MW-AL-07","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Zeitintervallmessgeräte","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"100 ns to 1000 s","cmc":"1,4 ns + 9 · 10⁻¹⁰ · T"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"时间间隔测量仪 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) MW-AL-07","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"时间间隔测量仪","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"100 ns to 1000 s","cmc":"1,4 ns + 9 · 10⁻¹⁰ · T"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Měřiče časového intervalu Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) MW-AL-07","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Měřiče časového intervalu"},{"_id":"b9174b699c08d2dc342f5cba","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Oscyloskopy","test_object_en":"Oscilloscopes","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"","range":"100 ns do 25 s","cmc":"1,4 ns + 2 · 10⁻⁵ · T"}],"parameters_en":[{"name":"","range":"100 ns to 25 s","cmc":"1,4 ns + 2 · 10⁻⁵ · T"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\n100 ns do 25 s CMC 1,4 ns + 2 · 10⁻⁵ · T\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"MW-AL-07","norm_bases":["MW-AL-07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":"T – wielkość mierzona (s)","note_en":"T – measured quantity (s)","search_text":"Oscyloskopy Wzorcowanie — Czas (przedział czasu)\n100 ns do 25 s CMC 1,4 ns + 2 · 10⁻⁵ · T\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) MW-AL-07 Oscyloskopy Wzorcowanie — Czas (przedzial czasu)\n100 ns do 25 s CMC 1,4 ns + 2 · 10⁻⁵ · T\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) MW-AL-07","search_en":"Oscilloscopes Calibration — Time (time interval) Internal procedure; Direct method; At permanent location (S) Time (time interval) Internal procedure Direct method At permanent location (S) MW-AL-07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Zeit (Zeitintervall)","parameters_de":[{"name":"","range":"100 ns to 25 s","cmc":"1,4 ns + 2 · 10⁻⁵ · T"}],"regulatory_area_de":"Zeit (Zeitintervall)","search_de":"Oszilloskope Kalibrierung — Zeit (Zeitintervall) Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Zeit (Zeitintervall) Internes Verfahren Direktes Verfahren Am festen Standort (S) MW-AL-07","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Oszilloskope","methodology_zh":"校准 — 时间（时间间隔）","parameters_zh":[{"name":"","range":"100 ns to 25 s","cmc":"1,4 ns + 2 · 10⁻⁵ · T"}],"regulatory_area_zh":"时间（时间间隔）","search_zh":"示波器 校准 — 时间（时间间隔） 内部程序；直接法；在固定地点 (S) 时间（时间间隔） 内部程序 直接法 在固定地点 (S) MW-AL-07","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"示波器","methodology_cs":"Kalibrace — Čas (časový interval)","parameters_cs":[{"name":"","range":"100 ns to 25 s","cmc":"1,4 ns + 2 · 10⁻⁵ · T"}],"regulatory_area_cs":"Čas (časový interval)","search_cs":"Osciloskopy Kalibrace — Čas (časový interval) Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Čas (časový interval) Vnitřní postup Přímá metoda Ve stálé lokalitě (S) MW-AL-07","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Osciloskopy"},{"_id":"e7f2bd01ac945ff0099be8e7","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Generatory częstotliwości kwarcowe","test_object_en":"Quartz frequency generators","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"0,01 Hz do 3,0 GHz","cmc":"20 µHz + 9 · 10⁻¹⁰ · F"}],"parameters_en":[{"name":"","range":"0,01 Hz to 3,0 GHz","cmc":"20 µHz + 9 · 10⁻¹⁰ · F"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n0,01 Hz do 3,0 GHz CMC 20 µHz + 9 · 10⁻¹⁰ · F\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"MW-AL-06","norm_bases":["MW-AL-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"(składnik 20 µHz dla przebiegów sinusoidalnych przy częstotliwości F < 10 kHz)\nF – wielkość mierzona (Hz)","note_en":"(the 20 µHz term for sinusoidal waveforms at frequency F < 10 kHz)\nF – measured quantity (Hz)","search_text":"Generatory częstotliwości kwarcowe Wzorcowanie — Częstotliwość\n0,01 Hz do 3,0 GHz CMC 20 µHz + 9 · 10⁻¹⁰ · F\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) MW-AL-06 Generatory czestotliwosci kwarcowe Wzorcowanie — Czestotliwosc\n0,01 Hz do 3,0 GHz CMC 20 µHz + 9 · 10⁻¹⁰ · F\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) MW-AL-06","search_en":"Quartz frequency generators Calibration — Frequency Internal procedure; Direct method; At permanent location (S) Frequency Internal procedure Direct method At permanent location (S) MW-AL-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"0,01 Hz to 3,0 GHz","cmc":"20 µHz + 9 · 10⁻¹⁰ · F"}],"regulatory_area_de":"Frequenz","search_de":"Quarzfrequenzgeneratoren Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) MW-AL-06","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Quarzfrequenzgeneratoren","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"0,01 Hz to 3,0 GHz","cmc":"20 µHz + 9 · 10⁻¹⁰ · F"}],"regulatory_area_zh":"频率","search_zh":"石英频率发生器 校准 — 频率 内部程序；直接法；在固定地点 (S) 频率 内部程序 直接法 在固定地点 (S) MW-AL-06","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"石英频率发生器","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"0,01 Hz to 3,0 GHz","cmc":"20 µHz + 9 · 10⁻¹⁰ · F"}],"regulatory_area_cs":"Frekvence","search_cs":"Krystalové generátory kmitočtu Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda Ve stálé lokalitě (S) MW-AL-06","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Krystalové generátory kmitočtu"},{"_id":"4f2bcf2b195b27b4adf5ad30","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Generatory częstotliwości bezkwarcowe","test_object_en":"Non-quartz frequency generators","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"0,01 Hz do 10 MHz","cmc":"1 · 10⁻⁶ · F"}],"parameters_en":[{"name":"","range":"0,01 Hz to 10 MHz","cmc":"1 · 10⁻⁶ · F"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n0,01 Hz do 10 MHz CMC 1 · 10⁻⁶ · F\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"MW-AL-06","norm_bases":["MW-AL-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"F – wielkość mierzona (Hz)","note_en":"F – measured quantity (Hz)","search_text":"Generatory częstotliwości bezkwarcowe Wzorcowanie — Częstotliwość\n0,01 Hz do 10 MHz CMC 1 · 10⁻⁶ · F\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) MW-AL-06 Generatory czestotliwosci bezkwarcowe Wzorcowanie — Czestotliwosc\n0,01 Hz do 10 MHz CMC 1 · 10⁻⁶ · F\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) MW-AL-06","search_en":"Non-quartz frequency generators Calibration — Frequency Internal procedure; Direct method; At permanent location (S) Frequency Internal procedure Direct method At permanent location (S) MW-AL-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"0,01 Hz to 10 MHz","cmc":"1 · 10⁻⁶ · F"}],"regulatory_area_de":"Frequenz","search_de":"Frequenzgeneratoren ohne Quarz Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) MW-AL-06","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Frequenzgeneratoren ohne Quarz","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"0,01 Hz to 10 MHz","cmc":"1 · 10⁻⁶ · F"}],"regulatory_area_zh":"频率","search_zh":"非石英频率发生器 校准 — 频率 内部程序；直接法；在固定地点 (S) 频率 内部程序 直接法 在固定地点 (S) MW-AL-06","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"非石英频率发生器","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"0,01 Hz to 10 MHz","cmc":"1 · 10⁻⁶ · F"}],"regulatory_area_cs":"Frekvence","search_cs":"Nekrystalové generátory kmitočtu Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda Ve stálé lokalitě (S) MW-AL-06","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Nekrystalové generátory kmitočtu"},{"_id":"bcea85297ad451fe1ba6ca0c","lab_id":"6af798950ecd48de0c7068a1","country":"PL","accr_number":"AP 161","accr_body":"PCA","test_object":"Mierniki częstotliwości analogowe\nMierniki częstotliwości cyfrowe (sygnał prostokątny)\nMultimetry","test_object_en":"Analogue frequency meters\nDigital frequency meters (square-wave signal)\nMultimeters","methodology":"Wzorcowanie — Częstotliwość","methodology_en":"Calibration — Frequency","parameters":[{"name":"","range":"0,04 Hz do 10 MHz","cmc":"9 · 10⁻¹⁰ · F"}],"parameters_en":[{"name":"","range":"0,04 Hz to 10 MHz","cmc":"9 · 10⁻¹⁰ · F"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Częstotliwość\n0,04 Hz do 10 MHz CMC 9 · 10⁻¹⁰ · F\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"MW-AL-07","norm_bases":["MW-AL-07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Częstotliwość","regulatory_area_en":"Frequency","outside_premises":false,"location_of_activity":"S","note":"F – wielkość mierzona (Hz)","note_en":"F – measured quantity (Hz)","search_text":"Mierniki częstotliwości analogowe\nMierniki częstotliwości cyfrowe (sygnał prostokątny)\nMultimetry Wzorcowanie — Częstotliwość\n0,04 Hz do 10 MHz CMC 9 · 10⁻¹⁰ · F\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) MW-AL-07 Mierniki czestotliwosci analogowe\nMierniki czestotliwosci cyfrowe (sygnal prostokatny)\nMultimetry Wzorcowanie — Czestotliwosc\n0,04 Hz do 10 MHz CMC 9 · 10⁻¹⁰ · F\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) MW-AL-07","search_en":"Analogue frequency meters Digital frequency meters (square-wave signal) Multimeters Calibration — Frequency Internal procedure; Direct method; At permanent location (S) Frequency Internal procedure Direct method At permanent location (S) MW-AL-07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Frequenz","parameters_de":[{"name":"","range":"0,04 Hz to 10 MHz","cmc":"9 · 10⁻¹⁰ · F"}],"regulatory_area_de":"Frequenz","search_de":"Analoge Frequenzmesser Digitale Frequenzmesser (Rechtecksignal) Multimeter Kalibrierung — Frequenz Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Frequenz Internes Verfahren Direktes Verfahren Am festen Standort (S) MW-AL-07","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Frequenzmesser\nDigitale Frequenzmesser (Rechtecksignal)\nMultimeter","methodology_zh":"校准 — 频率","parameters_zh":[{"name":"","range":"0,04 Hz to 10 MHz","cmc":"9 · 10⁻¹⁰ · F"}],"regulatory_area_zh":"频率","search_zh":"模拟式频率计 数字式频率计（方波信号） 万用表 校准 — 频率 内部程序；直接法；在固定地点 (S) 频率 内部程序 直接法 在固定地点 (S) MW-AL-07","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟式频率计\n数字式频率计（方波信号）\n万用表","methodology_cs":"Kalibrace — Kmitočet","parameters_cs":[{"name":"","range":"0,04 Hz to 10 MHz","cmc":"9 · 10⁻¹⁰ · F"}],"regulatory_area_cs":"Frekvence","search_cs":"Analogové měřiče kmitočtu Digitální měřiče kmitočtu (obdélníkový signál) Multimetry Kalibrace — Kmitočet Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Frekvence Vnitřní postup Přímá metoda Ve stálé lokalitě (S) MW-AL-07","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče kmitočtu\nDigitální měřiče kmitočtu (obdélníkový signál)\nMultimetry"}],"has_pdf":true}