🇵🇱 ARKOM-LAB Sp. z o.o. PL
Metrology & calibration
ARKOM-LAB Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 154 (Rzeszów, Poland). Its accreditation scope covers 78 calibration items in the following areas: Metrology & calibration. Calibrated items include: Special gauges, 90° cylindrical squares, 90° try squares, Analogue dial gauges with a scale interval of 0,001 mm. Most frequently used calibration principles: Internal procedure; using OPTIMAR; At permanent location (S), Internal procedure; using the O-Inspect coordinate measuring machin…, Internal procedure; using gauge blocks; At permanent location (S).
At a glance
- Accreditation number: PCA AP 154
- Calibration items in scope: 78
- Types of calibrated items: 77
- Calibration principles used: 15
- City: Rzeszów, Poland
- Valid until: 15-10-2029
- Accreditation number
- AP 154
- Accreditation body
- PCA
- Address
- ul. Hanasiewicza 14, 35-103 Rzeszów
- City
- Rzeszów, Poland
- Valid until
- 15-10-2029
What this laboratory calibrates (77)
- Special gauges — 2 calibration items
- 90° cylindrical squares — 1 calibration item
- 90° try squares — 1 calibration item
- Analogue dial gauges with a scale interval of 0,001 mm — 1 calibration item
- Analogue dial gauges with a scale interval of 0,002 mm — 1 calibration item
- Analogue dial gauges with a scale interval of 0,005 mm — 1 calibration item
- Analogue dial gauges with a scale interval of 0,01 mm — 1 calibration item
- Analogue dial gauges with a scale interval of 0,1 mm — 1 calibration item
- Analogue universal bevel protractors — 1 calibration item
- Cylindrical thread plug gauges and check plugs — 1 calibration item
- Cylindrical thread ring gauges — 1 calibration item
- Dial bore gauges with a digital indicator, resolution: — 1 calibration item
- Dial bore gauges with an analogue indicator, scale interval: — 1 calibration item
- Dial depth gauges with analogue reading, scale interval: — 1 calibration item
- Dial depth gauges with digital reading, resolution: — 1 calibration item
- and 62 more
Calibration principles (15)
- Internal procedure; using OPTIMAR; At permanent location (S) — 36 calibration items
- Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) — 11 calibration items
- Internal procedure; using gauge blocks; At permanent location (S) — 7 calibration items
- Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) — 5 calibration items
- At permanent location (S) — 4 calibration items
- Internal procedure; using angle gauge blocks; At permanent location (S) — 3 calibration items
- Internal procedure; measurement using the O-Inspect coordinate measuring machine; At permanent location (S) — 2 calibration items
- Internal procedure; using OPTIMAR and the O-Inspect coordinate measuring machine; At permanent location (S) — 2 calibration items
- Internal procedure; using setting rings; At permanent location (S) — 2 calibration items
- Internal procedure; measurement using a coordinate measuring machine; At permanent location (S) — 1 calibration item
- Internal procedure; using a digital micrometer; At permanent location (S) — 1 calibration item
- Internal procedure; using a MAHR comparator and class K gauge blocks; At permanent location (S) — 1 calibration item
- Internal procedure; using a MAHR horizontal length measuring machine and a reference plug; At permanent location (S) — 1 calibration item
- Internal procedure; using a MAHR horizontal length measuring machine and measuring rollers; At permanent location (S) — 1 calibration item
- Internal procedure; using Talyvel 6 differential levels; At permanent location (S) and outside of it (P) — 1 calibration item
Certificate information
- Issue date
- 30.07.2026
- Issue no.
- 20
- Certificate date
- 30.05.2025
- Accreditation cycle
- 16.09.2025 — 15.10.2029
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (78)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Gauge blocks class 0, 1, 2 | Calibration — Length 0,5 mm to 175 mm · CMC (0,06 + 0,0007 · L) µm Length |
Internal procedure; using a MAHR comparator and class K gauge blocks; At permanent location (S) | Internal procedure IW-1-LW-AK-01 based on the standard PN-EN ISO 3650:2000 | |
| 2 | Setting rings | Calibration — Length - ring diameter — 0,8 mm to 50 mm · CMC 1,3 µm - ring diameter — 50 mm to 100 mm · CMC 1,4 µm - ring diameter — 100 mm to 200 mm · CMC 1,5 µm - ring diameter — 200 mm to 300 mm · CMC 1,9 µm Length |
Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) | Internal procedure IW-2-LW-AK-01 | |
| 3 | Cylindrical thread plug gauges and check plugs | Calibration — Length - pitch diameter — 1 mm to 100 mm · CMC 3,0 µm - pitch diameter — 100 mm to 200 mm · CMC 3,1 µm - pitch diameter — 200 mm to 300 mm · CMC 3,4 µm Length |
Internal procedure; using a MAHR horizontal length measuring machine and measuring rollers; At permanent location (S) | Internal procedure IW-2-LW-AK-02 | |
| 4 | Cylindrical thread ring gauges | Calibration — Length - pitch diameter — 2,4 mm to 100 mm · CMC 3,1 µm - pitch diameter — 100 mm to 200 mm · CMC 3,2 µm - pitch diameter — 200 mm to 300 mm · CMC 3,5 µm Length |
Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) | Internal procedure IW-2-LW-AK-03 | |
| 5 | Taper thread plug gauges | Calibration — Length - pitch diameter — 4 mm to 100 mm · CMC 5,0 µm - pitch diameter — 100 mm to 200 mm · CMC 6,7 µm Length |
Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) | Internal procedure IW-2-LW-AK-04 | |
| 6 | Taper thread ring gauges | Calibration — Length - pitch diameter — 4 mm to 100 mm · CMC 5,0 µm - pitch diameter — 100 mm to 200 mm · CMC 6,7 µm Length |
Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) | Internal procedure IW-2-LW-AK-05 | |
| 7 | Plug gauges | Calibration — Length - plug diameter — 0,2 mm to 100 mm · CMC 1,0 µm - plug diameter — 100 mm to 200 mm · CMC 1,3 µm - plug diameter — 200 mm to 300 mm · CMC 1,6 µm Length |
Internal procedure; using a MAHR horizontal length measuring machine and a reference plug; At permanent location (S) | Internal procedure IW-2-LW-AK-06 | |
| 8 | Plain ring gauges | Calibration — Length - ring diameter — 0,8 mm to 50 mm · CMC 1,3 µm - ring diameter — 50 mm to 100 mm · CMC 1,4 µm - ring diameter — 100 mm to 200 mm · CMC 1,5 µm - ring diameter — 200 mm to 300 mm · CMC 1,9 µm Length |
Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) | Internal procedure IW-2-LW-AK-07 | |
| 9 | Analogue dial gauges with a scale interval of 0,001 mm | Calibration — Length 0 mm to 5 mm · CMC 0,6 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK 01 | |
| 10 | Analogue dial gauges with a scale interval of 0,002 mm | Calibration — Length 0 mm to 3 mm · CMC 0,6 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-01 | |
| 11 | Analogue dial gauges with a scale interval of 0,005 mm | Calibration — Length 0 mm to 10 mm · CMC 0,7 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-01 | |
| 12 | Analogue dial gauges with a scale interval of 0,01 mm | Calibration — Length 0 mm to 10 mm · CMC 1,2 µm 10 mm to 100 mm · CMC 2,1 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-01 | |
| 13 | Analogue dial gauges with a scale interval of 0,1 mm | Calibration — Length 0 mm to 100 mm · CMC 8,3 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-01 | |
| 14 | Digital dial gauges and digital micrometer-type gauges with a resolution of 0,0002 mm | Calibration — Length 0 mm to 10 mm · CMC 0,5 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 15 | Digital dial gauges with a resolution of 0,0002 mm | Calibration — Length 10 mm to 100 mm · CMC 0,7 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 16 | Digital dial gauges and digital micrometer-type gauges with a resolution of 0,0005 mm | Calibration — Length 0 mm to 10 mm · CMC 0,6 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 17 | Digital dial gauges with a resolution of 0,0005 mm | Calibration — Length 10 mm to 100 mm · CMC 0,8 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 18 | Digital dial gauges and digital micrometer-type gauges with a resolution of 0,001 mm | Calibration — Length 0 mm to 10 mm · CMC 0,6 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 19 | Digital dial gauges with a resolution of 0,001 mm | Calibration — Length 10 mm to 100 mm · CMC 1,5 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 20 | Digital dial gauges and digital micrometer-type gauges with a resolution of 0,002 mm | Calibration — Length 0 mm to 10 mm · CMC 1,3 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 21 | Digital dial gauges with a resolution of 0,002 mm | Calibration — Length 10 mm to 100 mm · CMC 1,4 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 22 | Digital dial gauges and digital micrometer-type gauges with a resolution of 0,005 mm | Calibration — Length 0 mm to 10 mm · CMC 1,3 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 23 | Digital dial gauges with a resolution of 0,005 mm | Calibration — Length 10 mm to 100 mm · CMC 1,4 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 24 | Digital dial gauges and digital micrometer-type gauges with a resolution of 0,01 mm | Calibration — Length 0 mm to 10 mm · CMC 1,8 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 25 | Digital dial gauges with a resolution of 0,01 mm | Calibration — Length 10 mm to 100 mm · CMC 2,1 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 26 | Digital dial gauges and digital micrometer-type gauges with a resolution of 0,02 mm | Calibration — Length 0 mm to 10 mm · CMC 5,8 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 27 | Digital dial gauges with a resolution of 0,02 mm | Calibration — Length 10 mm to 100 mm · CMC 5,9 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 28 | Digital dial gauges with a resolution of 0,05 mm | Calibration — Length 0 mm to 100 mm · CMC 14,5 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 29 | Digital dial gauges with a resolution of 0,1 mm | Calibration — Length 0 mm to 100 mm · CMC 28,9 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 30 | Digital dial gauges with a resolution of 0,2 mm | Calibration — Length 0 mm to 100 mm · CMC 57,8 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-02 | |
| 31 | Lever-type analogue dial gauges with a scale interval of 0,001 mm | Calibration — Length 0 mm to 0,6 mm · CMC 0,6 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-03 | |
| 32 | Lever-type analogue dial gauges with a scale interval of 0,002 mm | Calibration — Length 0 mm to 1,2 mm · CMC 0,6 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-03 | |
| 33 | Lever-type analogue dial gauges with a scale interval of 0,01 mm | Calibration — Length 0 mm to 3 mm · CMC 1,2 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-03 | |
| 34 | Lever-type analogue dial gauges with a scale interval of 0,02 mm | Calibration — Length 0 mm to 2 mm · CMC 1,7 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-03 | |
| 35 | Lever-type digital dial gauges with a resolution of 0,001 mm | Calibration — Length 0 mm to 2 mm · CMC 0,7 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-04 | |
| 36 | Lever-type digital dial gauges with a resolution of 0,01 mm | Calibration — Length 0 mm to 2 mm · CMC 1,2 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-04 | |
| 37 | Lever-gear analogue dial gauges with a scale interval of 0,0002 mm | Calibration — Length -0,015 mm to 0,015 mm · CMC 0,5 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-05 | |
| 38 | Lever-gear analogue dial gauges with a scale interval of 0,0005 mm | Calibration — Length -0,025 mm to 0,025 mm · CMC 0,5 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-05 | |
| 39 | Lever-gear analogue dial gauges with a scale interval of 0,001 mm | Calibration — Length -0,10 mm to 0,10 mm · CMC 0,5 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-05 | |
| 40 | Lever-gear analogue dial gauges with a scale interval of 0,002 mm | Calibration — Length -0,13 mm to 0,13 mm · CMC 0,5 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-05 | |
| 41 | Lever-gear analogue dial gauges with a scale interval of 0,005 mm | Calibration — Length -0,20 mm to 0,20 mm · CMC 0,7 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-05 | |
| 42 | Lever-gear analogue dial gauges with a scale interval of 0,01 mm | Calibration — Length -1,0 mm to 1,0 mm · CMC 1,0 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-05 | |
| 43 | Lever-gear analogue dial gauges with a scale interval of 0,05 mm | Calibration — Length -1,5 mm to 1,5 mm · CMC 4,1 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-05 | |
| 44 | Lever-gear analogue dial gauges with a scale interval of 0,1 mm | Calibration — Length -4,0 mm to 4,0 mm · CMC 8,2 µm Length |
Internal procedure; using OPTIMAR; At permanent location (S) | Internal procedure IW-3-LW-AK-05 | |
| 45 | Two-point and three-point inside micrometers | Calibration — Length 2 mm to 100 mm · CMC 2,3 µm 100 mm to 300 mm · CMC 2,8 µm Length |
Internal procedure; using setting rings; At permanent location (S) | Internal procedure IW-8-LW-AK-01 | |
| 46 | Test sieves | Calibration — Length 0,02 mm to 25 mm · CMC 4 µm 25 mm to 125 mm · CMC 8 µm Length |
Internal procedure; measurement using a coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-02 based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24 | |
| 47 | Vernier calipers | Calibration — Length 0 mm do 150 mm · CMC 14 µm 0 mm do 300 mm · CMC 15 µm 0 mm do 500 mm · CMC 17 µm 0 mm to 600 mm · CMC 20 µm 0 mm do 800 mm · CMC 20 µm 0 mm to 1000 mm · CMC 22 µm Length |
At permanent location (S) | PN-EN ISO 13385-1:2019 | |
| 48 | Vernier height gauges | Calibration — Length 0 mm do 150 mm · CMC 14 µm 0 mm do 300 mm · CMC 15 µm 0 mm do 500 mm · CMC 17 µm 0 mm to 600 mm · CMC 20 µm 0 mm do 800 mm · CMC 20 µm 0 mm to 1000 mm · CMC 22 µm Length |
At permanent location (S) | PN-EN ISO 13225-1:2020 | |
| 49 | Vernier depth gauges | Calibration — Length 0 mm to 150 mm · CMC 14 µm 0 mm to 300 mm · CMC 15 µm 0 mm to 500 mm · CMC 17 µm Length |
At permanent location (S) | PN-EN ISO 13385:2020 | |
| 50 | External micrometers | Calibration — Length 0 mm to 25 mm · CMC 1,0 µm 25 mm to 50 mm · CMC 1,2 µm 50 mm to 75 mm · CMC 1,5 µm 75 mm to 100 mm · CMC 1,8 µm 100 mm to 125 mm · CMC 2,1 µm 125 mm to 150 mm · CMC 2,4 µm 150 mm to 175 mm · CMC 2,7 µm 175 mm to 200 mm · CMC 3,0 µm 200 mm do 225 mm · CMC 3,4 µm 225 mm do 250 mm · CMC 3,7 µm 250 mm do 275 mm · CMC 4,1 µm 275 mm do 300 mm · CMC 4,4 µm 300 mm do 325 mm · CMC 4,7 µm 325 mm do 350 mm · CMC 5,1 µm 350 mm do 375 mm · CMC 5,4 µm 375 mm do 400 mm · CMC 5,7 µm 400 mm do 425 mm · CMC 6,1 µm 425 mm do 450 mm · CMC 6,4 µm 450 mm do 475 mm · CMC 6,8 µm 475 mm do 500 mm · CMC 7,1 µm Length |
At permanent location (S) | PN-EN ISO 3611:2023 | |
| 51 | Internal micrometers | Calibration — Length 5 mm to 100 mm · CMC 2,3 µm Length |
Internal procedure; using setting rings; At permanent location (S) | Internal procedure IW-10-LW-AK-01 | |
| 52 | Micrometer depth gauges | Calibration — Length 0 mm to 25 mm · CMC 1,0 µm 25 mm to 50 mm · CMC 1,2 µm 50 mm to 75 mm · CMC 1,5 µm 75 mm to 100 mm · CMC 1,8 µm 100 mm to 125 mm · CMC 2,1 µm 125 mm to 150 mm · CMC 2,4 µm 150 mm to 175 mm · CMC 2,7 µm 175 mm to 200 mm · CMC 3,0 µm 200 mm do 225 mm · CMC 3,4 µm 225 mm do 250 mm · CMC 3,7 µm 250 mm do 275 mm · CMC 4,1 µm 275 mm do 300 mm · CMC 4,4 µm 300 mm do 325 mm · CMC 4,7 µm 325 mm do 350 mm · CMC 5,1 µm 350 mm do 375 mm · CMC 5,4 µm 375 mm do 400 mm · CMC 5,7 µm 400 mm do 425 mm · CMC 6,1 µm 425 mm do 450 mm · CMC 6,4 µm 450 mm do 475 mm · CMC 6,8 µm 475 mm do 500 mm · CMC 7,1 µm Length |
Internal procedure; using gauge blocks; At permanent location (S) | Internal procedure IW-11-LW-AK-01 | |
| 53 | Dial depth gauges with analogue reading, scale interval: | Calibration — Length - 0,001 mm — 0 mm to 5 mm · CMC 0,6 µm - 0,002 mm — 0 mm to 5 mm · CMC 0,6 µm - 0,005 mm — 0 mm to 10 mm · CMC 0,7 µm - 0,01 mm — 0 mm to 10 mm · CMC 1,2 µm - 0,01 mm — 10 mm to 100 mm · CMC 2,1 µm - 0,1 mm — 0 mm to 100 mm · CMC 8,3 µm Length |
Internal procedure; using OPTIMAR and the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-6-LW-AK 01 | |
| 54 | Dial depth gauges with digital reading, resolution: | Calibration — Length - 0,0002 mm — 0 mm to 10 mm · CMC 0,5 µm - 0,0002 mm — 10 mm to 100 mm · CMC 0,7 µm - 0,0005 mm — 0 mm to 10 mm · CMC 0,5 µm - 0,0005 mm — 10 mm to 100 mm · CMC 0,7 µm - 0,001 mm — 0 mm to 10 mm · CMC 0,6 µm - 0,001 mm — 10 mm to 100 mm · CMC 1,5 µm - 0,002 mm — 0 mm to 10 mm · CMC 1,3 µm - 0,002 mm — 10 mm to 100 mm · CMC 1,4 µm - 0,005 mm — 0 mm to 10 mm · CMC 1,3 µm - 0,005 mm — 10 mm to 100 mm · CMC 1,4 µm - 0,01 mm — 0 mm to 10 mm · CMC 1,8 µm - 0,01 mm — 10 mm to 100 mm · CMC 2,1 µm - 0,02 mm — 0 mm to 100 mm · CMC 5,9 µm - 0,05 mm — 0 mm to 100 mm · CMC 14,5 µm - 0,1 mm — 0 mm to 100 mm · CMC 28,9 µm - 0,2 mm — 0 mm to 100 mm · CMC 57,8 µm Length |
Internal procedure; using OPTIMAR and the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-6-LW-AK 01 | |
| 55 | Dial thickness gauges with an analogue indicator, scale interval: | Calibration — Length - 0,001 mm — 0 mm to 5 mm · CMC 1,0 µm - 0,002 mm — 0 mm to 10 mm · CMC 1,0 µm - 0,005 mm — 0 mm to 10 mm · CMC 1,1 µm - 0,005 mm — 0 mm to 50 mm · CMC 1,3 µm - 0,005 mm — 0 mm to 75 mm · CMC 1,5 µm - 0,005 mm — 0 mm to 100 mm · CMC 1,8 µm - 0,01 mm — 0 mm to 25 mm · CMC 1,5 µm - 0,01 mm — 0 mm to 50 mm · CMC 1,6 µm - 0,01 mm — 0 mm to 75 mm · CMC 1,8 µm - 0,01 mm — 0 mm to 100 mm · CMC 2,0 µm - 0,1 mm — 0 mm to 60 mm · CMC 5,9 µm - 0,1 mm — 0 mm to 100 mm · CMC 6,0 µm Length |
Internal procedure; using gauge blocks; At permanent location (S) | Internal procedure IW-10-LW-AK-02 | |
| 56 | Dial thickness gauges with a digital indicator, resolution: | Calibration — Length - 0,001 mm — 0 mm to 25 mm · CMC 1,2 µm - 0,001 mm — 0 mm to 50 mm · CMC 1,4 µm - 0,001 mm — 0 mm to 75 mm · CMC 1,6 µm - 0,001 mm — 0 mm to 100 mm · CMC 1,9 µm - 0,002 mm — 0 mm to 25 mm · CMC 1,6 µm - 0,002 mm — 0 mm to 50 mm · CMC 1,7 µm - 0,002 mm — 0 mm to 75 mm · CMC 1,9 µm - 0,002 mm — 0 mm to 100 mm · CMC 2,1 µm - 0,005 mm — 0 mm to 50 mm · CMC 3,2 µm - 0,005 mm — 0 mm to 75 mm · CMC 3,3 µm - 0,005 mm — 0 mm to 100 mm · CMC 3,4 µm - 0,01 mm — 0 mm to 50 mm · CMC 5,9 µm - 0,01 mm — 0 mm to 100 mm · CMC 6,0 µm Length |
Internal procedure; using gauge blocks; At permanent location (S) | Internal procedure IW-10-LW-AK-02 | |
| 57 | External calipers | Calibration — Length 0 mm to 200 mm · CMC 3,5 µm Length |
Internal procedure; using gauge blocks; At permanent location (S) | Internal procedure IW-10-LW-AK-03 | |
| 58 | Internal calipers | Calibration — Length 2 mm do 25 mm · CMC 1,1 µm 25 mm to 50 mm · CMC 1,3 µm 50 mm to 75 mm · CMC 1,5 µm 75 mm to 100 mm · CMC 1,8 µm 100 mm do 150 mm · CMC 2,3 µm 150 mm do 200 mm · CMC 3,0 µm 200 mm do 250 mm · CMC 3,7 µm 250 mm do 300 mm · CMC 4,3 µm Length |
Internal procedure; using gauge blocks; At permanent location (S) | Internal procedure IW-10-LW-AK-03 | |
| 59 | Leaf feeler gauges | Calibration — Length 0,01 mm to 10,00 mm · CMC 4,9 µm Length |
Internal procedure; using a digital micrometer; At permanent location (S) | Internal procedure IW-10-LW-AK-04 | |
| 60 | 90° try squares | Calibration — Length deviation measurement - flatness — arm length up to 500 mm · CMC 4,2 µm deviation measurement - straightness — arm length up to 500 mm · CMC 4,2 µm deviation measurement - parallelism — arm length up to 500 mm · CMC 4,2 µm deviation measurement - perpendicularity — arm length up to 500 mm · CMC 4,2 µm Length |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-03 | |
| 61 | 90° cylindrical squares | Calibration — Length deviation measurement - straightness — 0 mm to 400 mm · CMC 4,2 µm deviation measurement - perpendicularity — 0 mm to 400 mm · CMC 4,2 µm Length |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-04 | |
| 62 | Dial bore gauges with an analogue indicator, scale interval: | Calibration — Length - 0,001 mm — 0 mm to 35 mm · CMC 3,7 µm - 0,001 mm — od 35 mm to 60 mm · CMC 3,8 µm - 0,001 mm — od 50 mm to 150 mm · CMC 4,3 µm - 0,001 mm — od 150 mm to 250 mm · CMC 5,2 µm - 0,001 mm — od 250 mm to 500 mm · CMC 7,9 µm - 0,002 mm — 0 mm to 35 mm · CMC 3,7 µm - 0,002 mm — od 35 mm to 60 mm · CMC 3,8 µm - 0,002 mm — od 50 mm to 150 mm · CMC 4,3 µm - 0,002 mm — od 150 mm to 250 mm · CMC 5,2 µm - 0,002 mm — od 250 mm to 500 mm · CMC 7,9 µm - 0,005 mm — 0 mm to 35 mm · CMC 3,8 µm - 0,005 mm — od 35 mm to 60 mm · CMC 3,8 µm - 0,005 mm — od 50 mm to 150 mm · CMC 4,4 µm - 0,005 mm — od 150 mm to 250 mm · CMC 5,2 µm - 0,005 mm — od 250 mm to 500 mm · CMC 7,9 µm - 0,01 mm — 0 mm to 35 mm · CMC 4,4 µm - 0,01 mm — od 35 mm to 60 mm · CMC 4,4 µm - 0,01 mm — od 50 mm to 150 mm · CMC 4,9 µm - 0,01 mm — od 150 mm to 250 mm · CMC 5,7 µm - 0,01 mm — od 250 mm to 500 mm · CMC 8,2 µm - 0,1 mm — 0 mm to 35 mm · CMC 10,8 µm - 0,1 mm — od 35 mm to 60 mm · CMC 10,9 µm - 0,1 mm — od 50 mm to 150 mm · CMC 11,0 µm - 0,1 mm — od 150 mm to 250 mm · CMC 11,4 µm - 0,1 mm — od 250 mm to 500 mm · CMC 12,9 µm Length |
Internal procedure; using gauge blocks; At permanent location (S) | Internal procedure IW-10-LW-AK-05 | |
| 63 | Dial bore gauges with a digital indicator, resolution: | Calibration — Length - 0,001 mm — 0 mm to 35 mm · CMC 4,1 µm - 0,001 mm — od 35 mm to 60 mm · CMC 4,2 µm - 0,001 mm — od 50 mm to 150 mm · CMC 4,7 µm - 0,001 mm — od 150 mm to 250 mm · CMC 5,5 µm - 0,001 mm — od 250 mm to 500 mm · CMC 8,1 µm - 0,002 mm — 0 mm to 35 mm · CMC 4,2 µm - 0,002 mm — od 35 mm to 60 mm · CMC 4,3 µm - 0,002 mm — od 50 mm to 150 mm · CMC 4,8 µm - 0,002 mm — od 150 mm to 250 mm · CMC 5,6 µm - 0,002 mm — od 250 mm to 500 mm · CMC 8,2 µm - 0,005 mm — 0 mm to 35 mm · CMC 5,0 µm - 0,005 mm — od 35 mm to 60 mm · CMC 5,1 µm - 0,005 mm — od 50 mm to 150 mm · CMC 5,5 mm - 0,005 mm — od 150 mm to 250 mm · CMC 6,2 µm - 0,005 mm — od 250 mm to 500 mm · CMC 8,6 µm - 0,01 mm — 0 mm to 35 mm · CMC 7,2 µm - 0,01 mm — od 35 mm to 60 mm · CMC 7,2 µm - 0,01 mm — od 50 mm to 150 mm · CMC 7,5 µm - 0,01 mm — od 150 mm to 250 mm · CMC 8,0 µm - 0,01 mm — od 250 mm to 500 mm · CMC 10,0 µm - 0,02 mm — 0 mm to 35 mm · CMC 13,5 µm - 0,02 mm — od 35 mm to 60 mm · CMC 13,6 µm - 0,02 mm — od 50 mm to 150 mm · CMC 13,7 µm - 0,02 mm — od 150 mm to 250 mm · CMC 14,00 µm - 0,02 mm — od 250 mm to 500 mm · CMC 15,2 µm - 0,05 mm — 0 mm to 35 mm · CMC 32,7µm - 0,05 mm — od 35 mm to 60 mm · CMC 32,7 µm - 0,05 mm — od 50 mm to 150 mm · CMC 32,8 µm - 0,05 mm — od 150 mm to 250 mm · CMC 32,9 µm - 0,05 mm — od 250 mm to 500 mm · CMC 33,5 µm Length |
Internal procedure; using gauge blocks; At permanent location (S) | Internal procedure IW-10-LW-AK-05 | |
| 64 | Rigid rules | Calibration — Length 0 mm to 750 mm · CMC (40,2 + 12,1 · L) µm Length |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-06 | |
| 65 | Semi-rigid rules | Calibration — Length 0 mm to 750 mm · CMC (40,2 + 22,2 · L) µm Length |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-06 | |
| 66 | Line scales of measuring magnifiers | Calibration — Length 0 mm to 20 mm · CMC 3,6 µm Length |
Internal procedure; measurement using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-08 | |
| 67 | Taper feeler gauges | Calibration — Length 0 mm to 50 mm · CMC 29,4 µm Length |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-12 | |
| 68 | Taper hole gauges | Calibration — Length 0 mm to 200 mm · CMC 20,0 µm Length |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-11 | |
| 69 | Weld gauges | Calibration — Length - vernier type — 0 mm to 50 mm · CMC 16,7 µm - special — 0 mm to 60 mm · CMC 16,7 µm Length |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-09 IW-9-LW-AK-10 | |
| 70 | Special gauges | Calibration — Angle 0° to 360° · CMC 48’’ Angle |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-01 | |
| 71 | Analogue universal bevel protractors | Calibration — Angle 4x90° · CMC 2,8’ Angle |
Internal procedure; using angle gauge blocks; At permanent location (S) | Internal procedure IW-11-LW-AK-03 | |
| 72 | Digital universal bevel protractors | Calibration — Angle 0° to 360° · CMC 2,5’ Angle |
Internal procedure; using angle gauge blocks; At permanent location (S) | Internal procedure IW-11-LW-AK-03 | |
| 73 | Digital levels | Calibration — Angle 4x90° · CMC 0,04° Angle |
Internal procedure; using angle gauge blocks; At permanent location (S) | Internal procedure IW-11-LW-AK-04 | |
| 74 | Weld gauges (bevel angle measurement) | Calibration — Angle - vernier type — 60° to 90° · CMC 5’ 11’’ - special — up to 160° · CMC 5’ 11’’ Angle |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-09 IW-9-LW-AK-10 | |
| 75 | Special try squares | Calibration — Angle 0° to 360° · CMC 48’’ Angle |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-05 | |
| 76 | Surface plates | Calibration — Length (surface geometry) - flatness deviation; length of the longer side — 250 mm · CMC 1,2 µm - flatness deviation; length of the longer side — 400 mm · CMC 1,7 µm - flatness deviation; length of the longer side — 500 mm · CMC 1,8 µm - flatness deviation; length of the longer side — 630 mm · CMC 2,8 µm - flatness deviation; length of the longer side — 800 mm · CMC 2,7 µm - flatness deviation; length of the longer side — 1000 mm · CMC 3,0 µm - flatness deviation; length of the longer side — 1200 mm · CMC 3,3 µm - flatness deviation; length of the longer side — 1600 mm · CMC 3,8 µm - flatness deviation; length of the longer side — 2000 mm · CMC 4,3 µm - flatness deviation; length of the longer side — 2500 mm · CMC 4,8 µm - flatness deviation; length of the longer side — 3000 mm · CMC 5,3 µm Length (surface geometry) |
Internal procedure; using Talyvel 6 differential levels; At permanent location (S) and outside of it (P) | Internal procedure IW-4-LW-AK-01 | |
| 77 | Straight edges | Calibration — Length (surface geometry) 0 mm to 750 mm · CMC 2,6 µm Length (surface geometry) |
Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-07 | |
| 78 | Special gauges | Calibration — Length (coordinate measurements) - length — 0 mm to 600 mm · CMC 4,2 µm - width — 0 mm to 400 mm · CMC 4,2 µm - diameter — 0 mm to 250 mm · CMC 4,2 µm - form deviation — 0 mm to 1 mm · CMC 3,0 µm - location deviations — 0 mm to 600 mm · CMC 4,1 µm Length (coordinate measurements) |
Internal procedure; measurement using the O-Inspect coordinate measuring machine; At permanent location (S) | Internal procedure IW-9-LW-AK-01 | |
Reference standards (47)
ASTM E11-24
IW-1-LW-AK-01
IW-10-LW-AK-01
IW-10-LW-AK-02
IW-10-LW-AK-03
IW-10-LW-AK-04
IW-10-LW-AK-05
IW-11-LW-AK-01
IW-11-LW-AK-03
IW-11-LW-AK-04
IW-2-LW-AK-01
IW-2-LW-AK-02
IW-2-LW-AK-03
IW-2-LW-AK-04
IW-2-LW-AK-05
IW-2-LW-AK-06
IW-2-LW-AK-07
IW-3-LW-AK 01
IW-3-LW-AK-01
IW-3-LW-AK-02
IW-3-LW-AK-03
IW-3-LW-AK-04
IW-3-LW-AK-05
IW-4-LW-AK-01
IW-6-LW-AK 01
IW-8-LW-AK-01
IW-9-LW-AK-01
IW-9-LW-AK-02
IW-9-LW-AK-03
IW-9-LW-AK-04
IW-9-LW-AK-05
IW-9-LW-AK-06
IW-9-LW-AK-07
IW-9-LW-AK-08
IW-9-LW-AK-09
IW-9-LW-AK-10
IW-9-LW-AK-11
IW-9-LW-AK-12
PN-EN 933-3:2012
PN-EN ISO 13225-1:2020
PN-EN ISO 13385-1:2019
PN-EN ISO 13385:2020
PN-EN ISO 3611:2023
PN-EN ISO 3650:2000
PN-ISO 3310-1:2000
PN-ISO 3310-2:2000
PN-ISO 3310-3:2000