{"lab":{"_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","imported_at":"2026-11-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Hanasiewicza 14, 35-103 Rzeszów","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"30.05.2025","city":"Rzeszów","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i wyrażona jest w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units.","cycle_from":"16.09.2025","cycle_to":"15.10.2029","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"6.02","pl":"kąt","en":"angle","de":"Winkel","zh":"角度","cs":"úhel"},{"codes":"6.03","pl":"długość (geometria powierzchni)","en":"length (surface geometry)","de":"Länge (Oberflächengeometrie)","zh":"长度（表面几何）","cs":"délka (geometrie povrchu)"},{"codes":"6.04","pl":"długość (pomiary współrzędnościowe)","en":"length (coordinate measurements)","de":"Länge (Koordinatenmesstechnik)","zh":"长度（坐标测量）","cs":"délka (souřadnicová měření)"}],"has_en":true,"has_zh":true,"issue":{"no":"20","date":"30.07.2026"},"issue_date":"30.07.2026","issue_number":"20","lab_division":null,"lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[21.9797174,50.0293791]},"map_coord":[50.0293791,21.9797174],"map_geo":"nominatim-street","methods_count":78,"name":"ARKOM-LAB Sp. z o.o.","parse_date":"2026-11-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-15T12:00:00.000Z","pdf_files":["AP_154.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: długość, kąt, długość (geometria powierzchni), długość (pomiary współrzędnościowe). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"arkom-lab sp. z o.o. ul. hanasiewicza 14, 35-103 rzeszów laboratorium wzorcujące. wielkości mierzone: długość, kąt, długość (geometria powierzchni), długość (pomiary współrzędnościowe). w stałej lokalizacji (s) i/lub poza nią (p). ap 154 ap154 laboratorium wzorcujące wzorcowanie kalibracja length angle length (surface geometry) length (coordinate measurements) arkom-lab sp. z o.o. ul. hanasiewicza 14, 35-103 rzeszow laboratorium wzorcujace. wielkosci mierzone: dlugosc, kat, dlugosc (geometria powierzchni), dlugosc (pomiary wspolrzednosciowe). w stalej lokalizacji (s) i/lub poza nia (p). ap 154 ap154 laboratorium wzorcujace wzorcowanie kalibracja length angle length (surface geometry) length (coordinate measurements)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20154,podmiot.html","source_pdf_sha256":"8b3fbeb70302bac2c80ad3d579f6736376a32ff8b912da85c1adf804c6110f91","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/15/d4f98c1a92a09c4a06ccdfaf5ef278dc/AP%20154.pdf","status":"active","updated_at":"2026-11-15T12:00:00.000Z","valid_from":"16-10-2013","valid_until":"15-10-2029","website":"www.arkomlab.pl","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben.","has_de":true,"cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny.","has_cs":true,"pelny_cs":true},"methods":[{"_id":"6a0b8adf1bd926d5e9bc87bc","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Płytki wzorcowe kl. 0, 1, 2","test_object_en":"Gauge blocks class 0, 1, 2","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,5 mm do 175 mm","cmc":"(0,06 + 0,0007 · L) µm"}],"parameters_en":[{"name":"","range":"0,5 mm to 175 mm","cmc":"(0,06 + 0,0007 · L) µm"}],"technique":"Procedura wewnętrzna; przy użyciu komparatora MAHR oraz płytek wzorcowych klasy K; W stałej lokalizacji (S)","technique_en":"Internal procedure; using a MAHR comparator and class K gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu komparatora MAHR oraz płytek wzorcowych klasy K","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using a MAHR comparator and class K gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,5 mm do 175 mm CMC (0,06 + 0,0007 · L) µm\nProcedura wewnętrzna; przy użyciu komparatora MAHR oraz płytek wzorcowych klasy K; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-1-LW-AK-01 w oparciu o normę PN-EN ISO 3650:2000","norm_bases":["IW-1-LW-AK-01","PN-EN ISO 3650:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L – wielkość mierzona (mm)","note_en":"L – measured quantity (mm)","search_text":"Płytki wzorcowe kl. 0, 1, 2 Wzorcowanie — Długość\n0,5 mm do 175 mm CMC (0,06 + 0,0007 · L) µm\nProcedura wewnętrzna; przy użyciu komparatora MAHR oraz płytek wzorcowych klasy K; W stałej lokalizacji (S) Procedura wewnętrzna IW-1-LW-AK-01 w oparciu o normę PN-EN ISO 3650:2000 Plytki wzorcowe kl. 0, 1, 2 Wzorcowanie — Dlugosc\n0,5 mm do 175 mm CMC (0,06 + 0,0007 · L) µm\nProcedura wewnetrzna; przy uzyciu komparatora MAHR oraz plytek wzorcowych klasy K; W stalej lokalizacji (S) Procedura wewnetrzna IW-1-LW-AK-01 w oparciu o norme PN-EN ISO 3650:2000","search_en":"Gauge blocks class 0, 1, 2 Calibration — Length Internal procedure; using a MAHR comparator and class K gauge blocks; At permanent location (S) Length Internal procedure using a MAHR comparator and class K gauge blocks At permanent location (S) Internal procedure IW-1-LW-AK-01 based on the standard PN-EN ISO 3650:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-1-LW-AK-01 based on the standard PN-EN ISO 3650:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,5 mm to 175 mm","cmc":"(0,06 + 0,0007 · L) µm"}],"reference_de":"Internes Verfahren IW-1-LW-AK-01 auf Grundlage der Norm PN-EN ISO 3650:2000","regulatory_area_de":"Länge","search_de":"Parallelendmaße Kl. 0, 1, 2 Kalibrierung — Länge Internes Verfahren; mit einem Komparator MAHR und Parallelendmaßen der Klasse K; Am festen Standort (S) Länge Internes Verfahren mit einem Komparator MAHR und Parallelendmaßen der Klasse K Am festen Standort (S) Internes Verfahren IW-1-LW-AK-01 auf Grundlage der Norm PN-EN ISO 3650:2000","technique_de":"Internes Verfahren; mit einem Komparator MAHR und Parallelendmaßen der Klasse K; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit einem Komparator MAHR und Parallelendmaßen der Klasse K","Am festen Standort (S)"],"test_object_de":"Parallelendmaße Kl. 0, 1, 2","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,5 mm to 175 mm","cmc":"(0,06 + 0,0007 · L) µm"}],"reference_zh":"内部程序 IW-1-LW-AK-01 依据标准PN-EN ISO 3650:2000","regulatory_area_zh":"长度","search_zh":"量块 0、1、2级 校准 — 长度 内部程序；使用MAHR比较仪和K级量块；在固定地点 (S) 长度 内部程序 使用MAHR比较仪和K级量块 在固定地点 (S) 内部程序 IW-1-LW-AK-01 依据标准PN-EN ISO 3650:2000","technique_zh":"内部程序；使用MAHR比较仪和K级量块；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR比较仪和K级量块","在固定地点 (S)"],"test_object_zh":"量块 0、1、2级","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,5 mm to 175 mm","cmc":"(0,06 + 0,0007 · L) µm"}],"reference_cs":"Vnitřní postup IW-1-LW-AK-01 na základě normy PN-EN ISO 3650:2000","regulatory_area_cs":"Délka","search_cs":"Koncové měrky tř. 0, 1, 2 Kalibrace — Délka Vnitřní postup; pomocí komparátoru MAHR a koncových měrek třídy K; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí komparátoru MAHR a koncových měrek třídy K Ve stálé lokalitě (S) Vnitřní postup IW-1-LW-AK-01 na základě normy PN-EN ISO 3650:2000","technique_cs":"Vnitřní postup; pomocí komparátoru MAHR a koncových měrek třídy K; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí komparátoru MAHR a koncových měrek třídy K","Ve stálé lokalitě (S)"],"test_object_cs":"Koncové měrky tř. 0, 1, 2"},{"_id":"b86f83d23308f5154e1e568f","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Pierścienie wzorcowe","test_object_en":"Setting rings","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- średnica pierścienia","range":"0,8 mm do 50 mm","cmc":"1,3 µm"},{"name":"- średnica pierścienia","range":"50 mm do 100 mm","cmc":"1,4 µm"},{"name":"- średnica pierścienia","range":"100 mm do 200 mm","cmc":"1,5 µm"},{"name":"- średnica pierścienia","range":"200 mm do 300 mm","cmc":"1,9 µm"}],"parameters_en":[{"name":"- ring diameter","range":"0,8 mm to 50 mm","cmc":"1,3 µm"},{"name":"- ring diameter","range":"50 mm to 100 mm","cmc":"1,4 µm"},{"name":"- ring diameter","range":"100 mm to 200 mm","cmc":"1,5 µm"},{"name":"- ring diameter","range":"200 mm to 300 mm","cmc":"1,9 µm"}],"technique":"Procedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using a MAHR horizontal length measuring machine and setting rings","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- średnica pierścienia 0,8 mm do 50 mm CMC 1,3 µm\n- średnica pierścienia 50 mm do 100 mm CMC 1,4 µm\n- średnica pierścienia 100 mm do 200 mm CMC 1,5 µm\n- średnica pierścienia 200 mm do 300 mm CMC 1,9 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-2-LW-AK-01","norm_bases":["IW-2-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Pierścienie wzorcowe Wzorcowanie — Długość\nZakres:\n- średnica pierścienia 0,8 mm do 50 mm CMC 1,3 µm\n- średnica pierścienia 50 mm do 100 mm CMC 1,4 µm\n- średnica pierścienia 100 mm do 200 mm CMC 1,5 µm\n- średnica pierścienia 200 mm do 300 mm CMC 1,9 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-2-LW-AK-01 Pierscienie wzorcowe Wzorcowanie — Dlugosc\nZakres:\n- srednica pierscienia 0,8 mm do 50 mm CMC 1,3 µm\n- srednica pierscienia 50 mm do 100 mm CMC 1,4 µm\n- srednica pierscienia 100 mm do 200 mm CMC 1,5 µm\n- srednica pierscienia 200 mm do 300 mm CMC 1,9 µm\nProcedura wewnetrzna; przy uzyciu dlugosciomierza poziomego MAHR oraz pierscieni wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-2-LW-AK-01","search_en":"Setting rings Calibration — Length Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) Length Internal procedure using a MAHR horizontal length measuring machine and setting rings At permanent location (S) - ring diameter - ring diameter - ring diameter - ring diameter Internal procedure IW-2-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-2-LW-AK-01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Ringdurchmesser","range":"0,8 mm to 50 mm","cmc":"1,3 µm"},{"name":"- Ringdurchmesser","range":"50 mm to 100 mm","cmc":"1,4 µm"},{"name":"- Ringdurchmesser","range":"100 mm to 200 mm","cmc":"1,5 µm"},{"name":"- Ringdurchmesser","range":"200 mm to 300 mm","cmc":"1,9 µm"}],"reference_de":"Internes Verfahren IW-2-LW-AK-01","regulatory_area_de":"Länge","search_de":"Normalringe Kalibrierung — Länge Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Einstellringen; Am festen Standort (S) Länge Internes Verfahren mit einem Horizontal-Längenmessgerät MAHR und Einstellringen Am festen Standort (S) - Ringdurchmesser - Ringdurchmesser - Ringdurchmesser - Ringdurchmesser Internes Verfahren IW-2-LW-AK-01","technique_de":"Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Einstellringen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit einem Horizontal-Längenmessgerät MAHR und Einstellringen","Am festen Standort (S)"],"test_object_de":"Normalringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 环规直径","range":"0,8 mm to 50 mm","cmc":"1,3 µm"},{"name":"- 环规直径","range":"50 mm to 100 mm","cmc":"1,4 µm"},{"name":"- 环规直径","range":"100 mm to 200 mm","cmc":"1,5 µm"},{"name":"- 环规直径","range":"200 mm to 300 mm","cmc":"1,9 µm"}],"reference_zh":"内部程序 IW-2-LW-AK-01","regulatory_area_zh":"长度","search_zh":"标准环规 校准 — 长度 内部程序；使用MAHR卧式测长仪和校对环规；在固定地点 (S) 长度 内部程序 使用MAHR卧式测长仪和校对环规 在固定地点 (S) - 环规直径 - 环规直径 - 环规直径 - 环规直径 内部程序 IW-2-LW-AK-01","technique_zh":"内部程序；使用MAHR卧式测长仪和校对环规；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR卧式测长仪和校对环规","在固定地点 (S)"],"test_object_zh":"标准环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- průměr kroužku","range":"0,8 mm to 50 mm","cmc":"1,3 µm"},{"name":"- průměr kroužku","range":"50 mm to 100 mm","cmc":"1,4 µm"},{"name":"- průměr kroužku","range":"100 mm to 200 mm","cmc":"1,5 µm"},{"name":"- průměr kroužku","range":"200 mm to 300 mm","cmc":"1,9 µm"}],"reference_cs":"Vnitřní postup IW-2-LW-AK-01","regulatory_area_cs":"Délka","search_cs":"Etalonové kroužky Kalibrace — Délka Vnitřní postup; pomocí vodorovného délkoměru MAHR a nastavovacích kroužků; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí vodorovného délkoměru MAHR a nastavovacích kroužků Ve stálé lokalitě (S) - průměr kroužku - průměr kroužku - průměr kroužku - průměr kroužku Vnitřní postup IW-2-LW-AK-01","technique_cs":"Vnitřní postup; pomocí vodorovného délkoměru MAHR a nastavovacích kroužků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí vodorovného délkoměru MAHR a nastavovacích kroužků","Ve stálé lokalitě (S)"],"test_object_cs":"Etalonové kroužky"},{"_id":"f4ea5b9e697bb0ed8b3d1616","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Sprawdziany i przeciwsprawdziany gwintowe trzpieniowe walcowe","test_object_en":"Cylindrical thread plug gauges and check plugs","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- średnica podziałowa","range":"1 mm do 100 mm","cmc":"3,0 µm"},{"name":"- średnica podziałowa","range":"100 mm do 200 mm","cmc":"3,1 µm"},{"name":"- średnica podziałowa","range":"200 mm do 300 mm","cmc":"3,4 µm"}],"parameters_en":[{"name":"- pitch diameter","range":"1 mm to 100 mm","cmc":"3,0 µm"},{"name":"- pitch diameter","range":"100 mm to 200 mm","cmc":"3,1 µm"},{"name":"- pitch diameter","range":"200 mm to 300 mm","cmc":"3,4 µm"}],"technique":"Procedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz wałeczków pomiarowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using a MAHR horizontal length measuring machine and measuring rollers; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu długościomierza poziomego MAHR oraz wałeczków pomiarowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using a MAHR horizontal length measuring machine and measuring rollers","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- średnica podziałowa 1 mm do 100 mm CMC 3,0 µm\n- średnica podziałowa 100 mm do 200 mm CMC 3,1 µm\n- średnica podziałowa 200 mm do 300 mm CMC 3,4 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz wałeczków pomiarowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-2-LW-AK-02","norm_bases":["IW-2-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany i przeciwsprawdziany gwintowe trzpieniowe walcowe Wzorcowanie — Długość\nZakres:\n- średnica podziałowa 1 mm do 100 mm CMC 3,0 µm\n- średnica podziałowa 100 mm do 200 mm CMC 3,1 µm\n- średnica podziałowa 200 mm do 300 mm CMC 3,4 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz wałeczków pomiarowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-2-LW-AK-02 Sprawdziany i przeciwsprawdziany gwintowe trzpieniowe walcowe Wzorcowanie — Dlugosc\nZakres:\n- srednica podzialowa 1 mm do 100 mm CMC 3,0 µm\n- srednica podzialowa 100 mm do 200 mm CMC 3,1 µm\n- srednica podzialowa 200 mm do 300 mm CMC 3,4 µm\nProcedura wewnetrzna; przy uzyciu dlugosciomierza poziomego MAHR oraz waleczkow pomiarowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-2-LW-AK-02","search_en":"Cylindrical thread plug gauges and check plugs Calibration — Length Internal procedure; using a MAHR horizontal length measuring machine and measuring rollers; At permanent location (S) Length Internal procedure using a MAHR horizontal length measuring machine and measuring rollers At permanent location (S) - pitch diameter - pitch diameter - pitch diameter Internal procedure IW-2-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-2-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Flankendurchmesser","range":"1 mm to 100 mm","cmc":"3,0 µm"},{"name":"- Flankendurchmesser","range":"100 mm to 200 mm","cmc":"3,1 µm"},{"name":"- Flankendurchmesser","range":"200 mm to 300 mm","cmc":"3,4 µm"}],"reference_de":"Internes Verfahren IW-2-LW-AK-02","regulatory_area_de":"Länge","search_de":"Zylindrische Gewindelehrdorne und Prüfdorne Kalibrierung — Länge Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Messrollen; Am festen Standort (S) Länge Internes Verfahren mit einem Horizontal-Längenmessgerät MAHR und Messrollen Am festen Standort (S) - Flankendurchmesser - Flankendurchmesser - Flankendurchmesser Internes Verfahren IW-2-LW-AK-02","technique_de":"Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Messrollen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit einem Horizontal-Längenmessgerät MAHR und Messrollen","Am festen Standort (S)"],"test_object_de":"Zylindrische Gewindelehrdorne und Prüfdorne","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 中径","range":"1 mm to 100 mm","cmc":"3,0 µm"},{"name":"- 中径","range":"100 mm to 200 mm","cmc":"3,1 µm"},{"name":"- 中径","range":"200 mm to 300 mm","cmc":"3,4 µm"}],"reference_zh":"内部程序 IW-2-LW-AK-02","regulatory_area_zh":"长度","search_zh":"圆柱螺纹塞规及校对塞规 校准 — 长度 内部程序；使用MAHR卧式测长仪和测量棒；在固定地点 (S) 长度 内部程序 使用MAHR卧式测长仪和测量棒 在固定地点 (S) - 中径 - 中径 - 中径 内部程序 IW-2-LW-AK-02","technique_zh":"内部程序；使用MAHR卧式测长仪和测量棒；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR卧式测长仪和测量棒","在固定地点 (S)"],"test_object_zh":"圆柱螺纹塞规及校对塞规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- střední průměr","range":"1 mm to 100 mm","cmc":"3,0 µm"},{"name":"- střední průměr","range":"100 mm to 200 mm","cmc":"3,1 µm"},{"name":"- střední průměr","range":"200 mm to 300 mm","cmc":"3,4 µm"}],"reference_cs":"Vnitřní postup IW-2-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Válcové závitové kalibry a kontrolní kalibry Kalibrace — Délka Vnitřní postup; pomocí vodorovného délkoměru MAHR a měřicích válečků; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí vodorovného délkoměru MAHR a měřicích válečků Ve stálé lokalitě (S) - střední průměr - střední průměr - střední průměr Vnitřní postup IW-2-LW-AK-02","technique_cs":"Vnitřní postup; pomocí vodorovného délkoměru MAHR a měřicích válečků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí vodorovného délkoměru MAHR a měřicích válečků","Ve stálé lokalitě (S)"],"test_object_cs":"Válcové závitové kalibry a kontrolní kalibry"},{"_id":"5d1d5d03e257d94c75b2ed84","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Sprawdziany gwintowe pierścieniowe walcowe","test_object_en":"Cylindrical thread ring gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- średnica podziałowa","range":"2,4 mm do 100 mm","cmc":"3,1 µm"},{"name":"- średnica podziałowa","range":"100 mm do 200 mm","cmc":"3,2 µm"},{"name":"- średnica podziałowa","range":"200 mm do 300 mm","cmc":"3,5 µm"}],"parameters_en":[{"name":"- pitch diameter","range":"2,4 mm to 100 mm","cmc":"3,1 µm"},{"name":"- pitch diameter","range":"100 mm to 200 mm","cmc":"3,2 µm"},{"name":"- pitch diameter","range":"200 mm to 300 mm","cmc":"3,5 µm"}],"technique":"Procedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using a MAHR horizontal length measuring machine and setting rings","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- średnica podziałowa 2,4 mm do 100 mm CMC 3,1 µm\n- średnica podziałowa 100 mm do 200 mm CMC 3,2 µm\n- średnica podziałowa 200 mm do 300 mm CMC 3,5 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-2-LW-AK-03","norm_bases":["IW-2-LW-AK-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe pierścieniowe walcowe Wzorcowanie — Długość\nZakres:\n- średnica podziałowa 2,4 mm do 100 mm CMC 3,1 µm\n- średnica podziałowa 100 mm do 200 mm CMC 3,2 µm\n- średnica podziałowa 200 mm do 300 mm CMC 3,5 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-2-LW-AK-03 Sprawdziany gwintowe pierscieniowe walcowe Wzorcowanie — Dlugosc\nZakres:\n- srednica podzialowa 2,4 mm do 100 mm CMC 3,1 µm\n- srednica podzialowa 100 mm do 200 mm CMC 3,2 µm\n- srednica podzialowa 200 mm do 300 mm CMC 3,5 µm\nProcedura wewnetrzna; przy uzyciu dlugosciomierza poziomego MAHR oraz pierscieni wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-2-LW-AK-03","search_en":"Cylindrical thread ring gauges Calibration — Length Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) Length Internal procedure using a MAHR horizontal length measuring machine and setting rings At permanent location (S) - pitch diameter - pitch diameter - pitch diameter Internal procedure IW-2-LW-AK-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-2-LW-AK-03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Flankendurchmesser","range":"2,4 mm to 100 mm","cmc":"3,1 µm"},{"name":"- Flankendurchmesser","range":"100 mm to 200 mm","cmc":"3,2 µm"},{"name":"- Flankendurchmesser","range":"200 mm to 300 mm","cmc":"3,5 µm"}],"reference_de":"Internes Verfahren IW-2-LW-AK-03","regulatory_area_de":"Länge","search_de":"Zylindrische Gewindelehrringe Kalibrierung — Länge Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Einstellringen; Am festen Standort (S) Länge Internes Verfahren mit einem Horizontal-Längenmessgerät MAHR und Einstellringen Am festen Standort (S) - Flankendurchmesser - Flankendurchmesser - Flankendurchmesser Internes Verfahren IW-2-LW-AK-03","technique_de":"Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Einstellringen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit einem Horizontal-Längenmessgerät MAHR und Einstellringen","Am festen Standort (S)"],"test_object_de":"Zylindrische Gewindelehrringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 中径","range":"2,4 mm to 100 mm","cmc":"3,1 µm"},{"name":"- 中径","range":"100 mm to 200 mm","cmc":"3,2 µm"},{"name":"- 中径","range":"200 mm to 300 mm","cmc":"3,5 µm"}],"reference_zh":"内部程序 IW-2-LW-AK-03","regulatory_area_zh":"长度","search_zh":"圆柱螺纹环规 校准 — 长度 内部程序；使用MAHR卧式测长仪和校对环规；在固定地点 (S) 长度 内部程序 使用MAHR卧式测长仪和校对环规 在固定地点 (S) - 中径 - 中径 - 中径 内部程序 IW-2-LW-AK-03","technique_zh":"内部程序；使用MAHR卧式测长仪和校对环规；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR卧式测长仪和校对环规","在固定地点 (S)"],"test_object_zh":"圆柱螺纹环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- střední průměr","range":"2,4 mm to 100 mm","cmc":"3,1 µm"},{"name":"- střední průměr","range":"100 mm to 200 mm","cmc":"3,2 µm"},{"name":"- střední průměr","range":"200 mm to 300 mm","cmc":"3,5 µm"}],"reference_cs":"Vnitřní postup IW-2-LW-AK-03","regulatory_area_cs":"Délka","search_cs":"Závitové kroužky válcové Kalibrace — Délka Vnitřní postup; pomocí vodorovného délkoměru MAHR a nastavovacích kroužků; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí vodorovného délkoměru MAHR a nastavovacích kroužků Ve stálé lokalitě (S) - střední průměr - střední průměr - střední průměr Vnitřní postup IW-2-LW-AK-03","technique_cs":"Vnitřní postup; pomocí vodorovného délkoměru MAHR a nastavovacích kroužků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí vodorovného délkoměru MAHR a nastavovacích kroužků","Ve stálé lokalitě (S)"],"test_object_cs":"Závitové kroužky válcové"},{"_id":"4818bfe2375528ee55b29497","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Sprawdziany gwintowe trzpieniowe stożkowe","test_object_en":"Taper thread plug gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- średnica podziałowa","range":"4 mm do 100 mm","cmc":"5,0 µm"},{"name":"- średnica podziałowa","range":"100 mm do 200 mm","cmc":"6,7 µm"}],"parameters_en":[{"name":"- pitch diameter","range":"4 mm to 100 mm","cmc":"5,0 µm"},{"name":"- pitch diameter","range":"100 mm to 200 mm","cmc":"6,7 µm"}],"technique":"Procedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using a MAHR horizontal length measuring machine and setting rings","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- średnica podziałowa 4 mm do 100 mm CMC 5,0 µm\n- średnica podziałowa 100 mm do 200 mm CMC 6,7 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-2-LW-AK-04","norm_bases":["IW-2-LW-AK-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe trzpieniowe stożkowe Wzorcowanie — Długość\nZakres:\n- średnica podziałowa 4 mm do 100 mm CMC 5,0 µm\n- średnica podziałowa 100 mm do 200 mm CMC 6,7 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-2-LW-AK-04 Sprawdziany gwintowe trzpieniowe stozkowe Wzorcowanie — Dlugosc\nZakres:\n- srednica podzialowa 4 mm do 100 mm CMC 5,0 µm\n- srednica podzialowa 100 mm do 200 mm CMC 6,7 µm\nProcedura wewnetrzna; przy uzyciu dlugosciomierza poziomego MAHR oraz pierscieni wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-2-LW-AK-04","search_en":"Taper thread plug gauges Calibration — Length Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) Length Internal procedure using a MAHR horizontal length measuring machine and setting rings At permanent location (S) - pitch diameter - pitch diameter Internal procedure IW-2-LW-AK-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-2-LW-AK-04","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Flankendurchmesser","range":"4 mm to 100 mm","cmc":"5,0 µm"},{"name":"- Flankendurchmesser","range":"100 mm to 200 mm","cmc":"6,7 µm"}],"reference_de":"Internes Verfahren IW-2-LW-AK-04","regulatory_area_de":"Länge","search_de":"Kegelige Gewindelehrdorne Kalibrierung — Länge Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Einstellringen; Am festen Standort (S) Länge Internes Verfahren mit einem Horizontal-Längenmessgerät MAHR und Einstellringen Am festen Standort (S) - Flankendurchmesser - Flankendurchmesser Internes Verfahren IW-2-LW-AK-04","technique_de":"Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Einstellringen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit einem Horizontal-Längenmessgerät MAHR und Einstellringen","Am festen Standort (S)"],"test_object_de":"Kegelige Gewindelehrdorne","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 中径","range":"4 mm to 100 mm","cmc":"5,0 µm"},{"name":"- 中径","range":"100 mm to 200 mm","cmc":"6,7 µm"}],"reference_zh":"内部程序 IW-2-LW-AK-04","regulatory_area_zh":"长度","search_zh":"锥度螺纹塞规 校准 — 长度 内部程序；使用MAHR卧式测长仪和校对环规；在固定地点 (S) 长度 内部程序 使用MAHR卧式测长仪和校对环规 在固定地点 (S) - 中径 - 中径 内部程序 IW-2-LW-AK-04","technique_zh":"内部程序；使用MAHR卧式测长仪和校对环规；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR卧式测长仪和校对环规","在固定地点 (S)"],"test_object_zh":"锥度螺纹塞规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- střední průměr","range":"4 mm to 100 mm","cmc":"5,0 µm"},{"name":"- střední průměr","range":"100 mm to 200 mm","cmc":"6,7 µm"}],"reference_cs":"Vnitřní postup IW-2-LW-AK-04","regulatory_area_cs":"Délka","search_cs":"Kuželové závitové kalibry Kalibrace — Délka Vnitřní postup; pomocí vodorovného délkoměru MAHR a nastavovacích kroužků; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí vodorovného délkoměru MAHR a nastavovacích kroužků Ve stálé lokalitě (S) - střední průměr - střední průměr Vnitřní postup IW-2-LW-AK-04","technique_cs":"Vnitřní postup; pomocí vodorovného délkoměru MAHR a nastavovacích kroužků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí vodorovného délkoměru MAHR a nastavovacích kroužků","Ve stálé lokalitě (S)"],"test_object_cs":"Kuželové závitové kalibry"},{"_id":"12e80855054f9f431cee6c1c","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Sprawdziany gwintowe pierścieniowe stożkowe","test_object_en":"Taper thread ring gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- średnica podziałowa","range":"4 mm do 100 mm","cmc":"5,0 µm"},{"name":"- średnica podziałowa","range":"100 mm do 200 mm","cmc":"6,7 µm"}],"parameters_en":[{"name":"- pitch diameter","range":"4 mm to 100 mm","cmc":"5,0 µm"},{"name":"- pitch diameter","range":"100 mm to 200 mm","cmc":"6,7 µm"}],"technique":"Procedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using a MAHR horizontal length measuring machine and setting rings","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- średnica podziałowa 4 mm do 100 mm CMC 5,0 µm\n- średnica podziałowa 100 mm do 200 mm CMC 6,7 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-2-LW-AK-05","norm_bases":["IW-2-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany gwintowe pierścieniowe stożkowe Wzorcowanie — Długość\nZakres:\n- średnica podziałowa 4 mm do 100 mm CMC 5,0 µm\n- średnica podziałowa 100 mm do 200 mm CMC 6,7 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-2-LW-AK-05 Sprawdziany gwintowe pierscieniowe stozkowe Wzorcowanie — Dlugosc\nZakres:\n- srednica podzialowa 4 mm do 100 mm CMC 5,0 µm\n- srednica podzialowa 100 mm do 200 mm CMC 6,7 µm\nProcedura wewnetrzna; przy uzyciu dlugosciomierza poziomego MAHR oraz pierscieni wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-2-LW-AK-05","search_en":"Taper thread ring gauges Calibration — Length Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) Length Internal procedure using a MAHR horizontal length measuring machine and setting rings At permanent location (S) - pitch diameter - pitch diameter Internal procedure IW-2-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-2-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Flankendurchmesser","range":"4 mm to 100 mm","cmc":"5,0 µm"},{"name":"- Flankendurchmesser","range":"100 mm to 200 mm","cmc":"6,7 µm"}],"reference_de":"Internes Verfahren IW-2-LW-AK-05","regulatory_area_de":"Länge","search_de":"Kegelige Gewindelehrringe Kalibrierung — Länge Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Einstellringen; Am festen Standort (S) Länge Internes Verfahren mit einem Horizontal-Längenmessgerät MAHR und Einstellringen Am festen Standort (S) - Flankendurchmesser - Flankendurchmesser Internes Verfahren IW-2-LW-AK-05","technique_de":"Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Einstellringen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit einem Horizontal-Längenmessgerät MAHR und Einstellringen","Am festen Standort (S)"],"test_object_de":"Kegelige Gewindelehrringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 中径","range":"4 mm to 100 mm","cmc":"5,0 µm"},{"name":"- 中径","range":"100 mm to 200 mm","cmc":"6,7 µm"}],"reference_zh":"内部程序 IW-2-LW-AK-05","regulatory_area_zh":"长度","search_zh":"锥度螺纹环规 校准 — 长度 内部程序；使用MAHR卧式测长仪和校对环规；在固定地点 (S) 长度 内部程序 使用MAHR卧式测长仪和校对环规 在固定地点 (S) - 中径 - 中径 内部程序 IW-2-LW-AK-05","technique_zh":"内部程序；使用MAHR卧式测长仪和校对环规；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR卧式测长仪和校对环规","在固定地点 (S)"],"test_object_zh":"锥度螺纹环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- střední průměr","range":"4 mm to 100 mm","cmc":"5,0 µm"},{"name":"- střední průměr","range":"100 mm to 200 mm","cmc":"6,7 µm"}],"reference_cs":"Vnitřní postup IW-2-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Kuželové závitové kroužky Kalibrace — Délka Vnitřní postup; pomocí vodorovného délkoměru MAHR a nastavovacích kroužků; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí vodorovného délkoměru MAHR a nastavovacích kroužků Ve stálé lokalitě (S) - střední průměr - střední průměr Vnitřní postup IW-2-LW-AK-05","technique_cs":"Vnitřní postup; pomocí vodorovného délkoměru MAHR a nastavovacích kroužků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí vodorovného délkoměru MAHR a nastavovacích kroužků","Ve stálé lokalitě (S)"],"test_object_cs":"Kuželové závitové kroužky"},{"_id":"1c6200975dd2b4f08d8a0a09","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Sprawdziany tłoczkowe","test_object_en":"Plug gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- średnica tłoczka","range":"0,2 mm do 100 mm","cmc":"1,0 µm"},{"name":"- średnica tłoczka","range":"100 mm do 200 mm","cmc":"1,3 µm"},{"name":"- średnica tłoczka","range":"200 mm do 300 mm","cmc":"1,6 µm"}],"parameters_en":[{"name":"- plug diameter","range":"0,2 mm to 100 mm","cmc":"1,0 µm"},{"name":"- plug diameter","range":"100 mm to 200 mm","cmc":"1,3 µm"},{"name":"- plug diameter","range":"200 mm to 300 mm","cmc":"1,6 µm"}],"technique":"Procedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz wzorca tłoczkowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; using a MAHR horizontal length measuring machine and a reference plug; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu długościomierza poziomego MAHR oraz wzorca tłoczkowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using a MAHR horizontal length measuring machine and a reference plug","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- średnica tłoczka 0,2 mm do 100 mm CMC 1,0 µm\n- średnica tłoczka 100 mm do 200 mm CMC 1,3 µm\n- średnica tłoczka 200 mm do 300 mm CMC 1,6 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz wzorca tłoczkowego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-2-LW-AK-06","norm_bases":["IW-2-LW-AK-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany tłoczkowe Wzorcowanie — Długość\nZakres:\n- średnica tłoczka 0,2 mm do 100 mm CMC 1,0 µm\n- średnica tłoczka 100 mm do 200 mm CMC 1,3 µm\n- średnica tłoczka 200 mm do 300 mm CMC 1,6 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz wzorca tłoczkowego; W stałej lokalizacji (S) Procedura wewnętrzna IW-2-LW-AK-06 Sprawdziany tloczkowe Wzorcowanie — Dlugosc\nZakres:\n- srednica tloczka 0,2 mm do 100 mm CMC 1,0 µm\n- srednica tloczka 100 mm do 200 mm CMC 1,3 µm\n- srednica tloczka 200 mm do 300 mm CMC 1,6 µm\nProcedura wewnetrzna; przy uzyciu dlugosciomierza poziomego MAHR oraz wzorca tloczkowego; W stalej lokalizacji (S) Procedura wewnetrzna IW-2-LW-AK-06","search_en":"Plug gauges Calibration — Length Internal procedure; using a MAHR horizontal length measuring machine and a reference plug; At permanent location (S) Length Internal procedure using a MAHR horizontal length measuring machine and a reference plug At permanent location (S) - plug diameter - plug diameter - plug diameter Internal procedure IW-2-LW-AK-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-2-LW-AK-06","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Lehrdorndurchmesser","range":"0,2 mm to 100 mm","cmc":"1,0 µm"},{"name":"- Lehrdorndurchmesser","range":"100 mm to 200 mm","cmc":"1,3 µm"},{"name":"- Lehrdorndurchmesser","range":"200 mm to 300 mm","cmc":"1,6 µm"}],"reference_de":"Internes Verfahren IW-2-LW-AK-06","regulatory_area_de":"Länge","search_de":"Lehrdorne Kalibrierung — Länge Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und einem Einstelldorn; Am festen Standort (S) Länge Internes Verfahren mit einem Horizontal-Längenmessgerät MAHR und einem Einstelldorn Am festen Standort (S) - Lehrdorndurchmesser - Lehrdorndurchmesser - Lehrdorndurchmesser Internes Verfahren IW-2-LW-AK-06","technique_de":"Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und einem Einstelldorn; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit einem Horizontal-Längenmessgerät MAHR und einem Einstelldorn","Am festen Standort (S)"],"test_object_de":"Lehrdorne","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 塞规直径","range":"0,2 mm to 100 mm","cmc":"1,0 µm"},{"name":"- 塞规直径","range":"100 mm to 200 mm","cmc":"1,3 µm"},{"name":"- 塞规直径","range":"200 mm to 300 mm","cmc":"1,6 µm"}],"reference_zh":"内部程序 IW-2-LW-AK-06","regulatory_area_zh":"长度","search_zh":"塞规 校准 — 长度 内部程序；使用MAHR卧式测长仪和校对塞规；在固定地点 (S) 长度 内部程序 使用MAHR卧式测长仪和校对塞规 在固定地点 (S) - 塞规直径 - 塞规直径 - 塞规直径 内部程序 IW-2-LW-AK-06","technique_zh":"内部程序；使用MAHR卧式测长仪和校对塞规；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR卧式测长仪和校对塞规","在固定地点 (S)"],"test_object_zh":"塞规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- průměr válečku","range":"0,2 mm to 100 mm","cmc":"1,0 µm"},{"name":"- průměr válečku","range":"100 mm to 200 mm","cmc":"1,3 µm"},{"name":"- průměr válečku","range":"200 mm to 300 mm","cmc":"1,6 µm"}],"reference_cs":"Vnitřní postup IW-2-LW-AK-06","regulatory_area_cs":"Délka","search_cs":"Kalibry trny Kalibrace — Délka Vnitřní postup; pomocí vodorovného délkoměru MAHR a etalonového válečku; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí vodorovného délkoměru MAHR a etalonového válečku Ve stálé lokalitě (S) - průměr válečku - průměr válečku - průměr válečku Vnitřní postup IW-2-LW-AK-06","technique_cs":"Vnitřní postup; pomocí vodorovného délkoměru MAHR a etalonového válečku; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí vodorovného délkoměru MAHR a etalonového válečku","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibry trny"},{"_id":"9e4747cfc6427cb0de93237b","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Sprawdziany pierścieniowe gładkie","test_object_en":"Plain ring gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- średnica pierścienia","range":"0,8 mm do 50 mm","cmc":"1,3 µm"},{"name":"- średnica pierścienia","range":"50 mm do 100 mm","cmc":"1,4 µm"},{"name":"- średnica pierścienia","range":"100 mm do 200 mm","cmc":"1,5 µm"},{"name":"- średnica pierścienia","range":"200 mm do 300 mm","cmc":"1,9 µm"}],"parameters_en":[{"name":"- ring diameter","range":"0,8 mm to 50 mm","cmc":"1,3 µm"},{"name":"- ring diameter","range":"50 mm to 100 mm","cmc":"1,4 µm"},{"name":"- ring diameter","range":"100 mm to 200 mm","cmc":"1,5 µm"},{"name":"- ring diameter","range":"200 mm to 300 mm","cmc":"1,9 µm"}],"technique":"Procedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using a MAHR horizontal length measuring machine and setting rings","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- średnica pierścienia 0,8 mm do 50 mm CMC 1,3 µm\n- średnica pierścienia 50 mm do 100 mm CMC 1,4 µm\n- średnica pierścienia 100 mm do 200 mm CMC 1,5 µm\n- średnica pierścienia 200 mm do 300 mm CMC 1,9 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-2-LW-AK-07","norm_bases":["IW-2-LW-AK-07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany pierścieniowe gładkie Wzorcowanie — Długość\nZakres:\n- średnica pierścienia 0,8 mm do 50 mm CMC 1,3 µm\n- średnica pierścienia 50 mm do 100 mm CMC 1,4 µm\n- średnica pierścienia 100 mm do 200 mm CMC 1,5 µm\n- średnica pierścienia 200 mm do 300 mm CMC 1,9 µm\nProcedura wewnętrzna; przy użyciu długościomierza poziomego MAHR oraz pierścieni wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-2-LW-AK-07 Sprawdziany pierscieniowe gladkie Wzorcowanie — Dlugosc\nZakres:\n- srednica pierscienia 0,8 mm do 50 mm CMC 1,3 µm\n- srednica pierscienia 50 mm do 100 mm CMC 1,4 µm\n- srednica pierscienia 100 mm do 200 mm CMC 1,5 µm\n- srednica pierscienia 200 mm do 300 mm CMC 1,9 µm\nProcedura wewnetrzna; przy uzyciu dlugosciomierza poziomego MAHR oraz pierscieni wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-2-LW-AK-07","search_en":"Plain ring gauges Calibration — Length Internal procedure; using a MAHR horizontal length measuring machine and setting rings; At permanent location (S) Length Internal procedure using a MAHR horizontal length measuring machine and setting rings At permanent location (S) - ring diameter - ring diameter - ring diameter - ring diameter Internal procedure IW-2-LW-AK-07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-2-LW-AK-07","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Ringdurchmesser","range":"0,8 mm to 50 mm","cmc":"1,3 µm"},{"name":"- Ringdurchmesser","range":"50 mm to 100 mm","cmc":"1,4 µm"},{"name":"- Ringdurchmesser","range":"100 mm to 200 mm","cmc":"1,5 µm"},{"name":"- Ringdurchmesser","range":"200 mm to 300 mm","cmc":"1,9 µm"}],"reference_de":"Internes Verfahren IW-2-LW-AK-07","regulatory_area_de":"Länge","search_de":"Glatte Lehrringe Kalibrierung — Länge Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Einstellringen; Am festen Standort (S) Länge Internes Verfahren mit einem Horizontal-Längenmessgerät MAHR und Einstellringen Am festen Standort (S) - Ringdurchmesser - Ringdurchmesser - Ringdurchmesser - Ringdurchmesser Internes Verfahren IW-2-LW-AK-07","technique_de":"Internes Verfahren; mit einem Horizontal-Längenmessgerät MAHR und Einstellringen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit einem Horizontal-Längenmessgerät MAHR und Einstellringen","Am festen Standort (S)"],"test_object_de":"Glatte Lehrringe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 环规直径","range":"0,8 mm to 50 mm","cmc":"1,3 µm"},{"name":"- 环规直径","range":"50 mm to 100 mm","cmc":"1,4 µm"},{"name":"- 环规直径","range":"100 mm to 200 mm","cmc":"1,5 µm"},{"name":"- 环规直径","range":"200 mm to 300 mm","cmc":"1,9 µm"}],"reference_zh":"内部程序 IW-2-LW-AK-07","regulatory_area_zh":"长度","search_zh":"光滑环规 校准 — 长度 内部程序；使用MAHR卧式测长仪和校对环规；在固定地点 (S) 长度 内部程序 使用MAHR卧式测长仪和校对环规 在固定地点 (S) - 环规直径 - 环规直径 - 环规直径 - 环规直径 内部程序 IW-2-LW-AK-07","technique_zh":"内部程序；使用MAHR卧式测长仪和校对环规；在固定地点 (S)","techniques_zh":["内部程序","使用MAHR卧式测长仪和校对环规","在固定地点 (S)"],"test_object_zh":"光滑环规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- průměr kroužku","range":"0,8 mm to 50 mm","cmc":"1,3 µm"},{"name":"- průměr kroužku","range":"50 mm to 100 mm","cmc":"1,4 µm"},{"name":"- průměr kroužku","range":"100 mm to 200 mm","cmc":"1,5 µm"},{"name":"- průměr kroužku","range":"200 mm to 300 mm","cmc":"1,9 µm"}],"reference_cs":"Vnitřní postup IW-2-LW-AK-07","regulatory_area_cs":"Délka","search_cs":"Hladké kroužky Kalibrace — Délka Vnitřní postup; pomocí vodorovného délkoměru MAHR a nastavovacích kroužků; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí vodorovného délkoměru MAHR a nastavovacích kroužků Ve stálé lokalitě (S) - průměr kroužku - průměr kroužku - průměr kroužku - průměr kroužku Vnitřní postup IW-2-LW-AK-07","technique_cs":"Vnitřní postup; pomocí vodorovného délkoměru MAHR a nastavovacích kroužků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí vodorovného délkoměru MAHR a nastavovacích kroužků","Ve stálé lokalitě (S)"],"test_object_cs":"Hladké kroužky"},{"_id":"35972011075312f6b92367c4","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,001 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 5 mm","cmc":"0,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 5 mm","cmc":"0,6 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 5 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK 01","norm_bases":["IW-3-LW-AK 01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,001 mm Wzorcowanie — Długość\n0 mm do 5 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK 01 Czujniki analogowe o wartosci dzialki elementarnej 0,001 mm Wzorcowanie — Dlugosc\n0 mm do 5 mm CMC 0,6 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK 01","search_en":"Analogue dial gauges with a scale interval of 0,001 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK 01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK 01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 5 mm","cmc":"0,6 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK 01","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,001 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK 01","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 5 mm","cmc":"0,6 µm"}],"reference_zh":"内部程序 IW-3-LW-AK 01","regulatory_area_zh":"长度","search_zh":"分度值 0,001 mm 的模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK 01","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,001 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 5 mm","cmc":"0,6 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK 01","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,001 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK 01","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,001 mm"},{"_id":"0f31fa4acf9dbb81b23758a9","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,002 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,002 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 3 mm","cmc":"0,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 3 mm","cmc":"0,6 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 3 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-01","norm_bases":["IW-3-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,002 mm Wzorcowanie — Długość\n0 mm do 3 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-01 Czujniki analogowe o wartosci dzialki elementarnej 0,002 mm Wzorcowanie — Dlugosc\n0 mm do 3 mm CMC 0,6 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-01","search_en":"Analogue dial gauges with a scale interval of 0,002 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 3 mm","cmc":"0,6 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-01","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,002 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-01","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,002 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 3 mm","cmc":"0,6 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-01","regulatory_area_zh":"长度","search_zh":"分度值 0,002 mm 的模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-01","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,002 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 3 mm","cmc":"0,6 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-01","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,002 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-01","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,002 mm"},{"_id":"68733522fa2203a6ab49d3bb","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,005 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"0,7 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10 mm","cmc":"0,7 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 10 mm CMC 0,7 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-01","norm_bases":["IW-3-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,005 mm Wzorcowanie — Długość\n0 mm do 10 mm CMC 0,7 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-01 Czujniki analogowe o wartosci dzialki elementarnej 0,005 mm Wzorcowanie — Dlugosc\n0 mm do 10 mm CMC 0,7 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-01","search_en":"Analogue dial gauges with a scale interval of 0,005 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 10 mm","cmc":"0,7 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-01","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,005 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-01","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 10 mm","cmc":"0,7 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-01","regulatory_area_zh":"长度","search_zh":"分度值 0,005 mm 的模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-01","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,005 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 10 mm","cmc":"0,7 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-01","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,005 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-01","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,005 mm"},{"_id":"65caffb0d141dba5f1a2036c","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,01 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"1,2 µm"},{"name":"","range":"10 mm do 100 mm","cmc":"2,1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10 mm","cmc":"1,2 µm"},{"name":"","range":"10 mm to 100 mm","cmc":"2,1 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 1,2 µm\n10 mm do 100 mm CMC 2,1 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-01","norm_bases":["IW-3-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,01 mm Wzorcowanie — Długość\nZakres:\n0 mm do 10 mm CMC 1,2 µm\n10 mm do 100 mm CMC 2,1 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-01 Czujniki analogowe o wartosci dzialki elementarnej 0,01 mm Wzorcowanie — Dlugosc\nZakres:\n0 mm do 10 mm CMC 1,2 µm\n10 mm do 100 mm CMC 2,1 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-01","search_en":"Analogue dial gauges with a scale interval of 0,01 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 10 mm","cmc":"1,2 µm"},{"name":"","range":"10 mm to 100 mm","cmc":"2,1 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-01","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,01 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-01","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 10 mm","cmc":"1,2 µm"},{"name":"","range":"10 mm to 100 mm","cmc":"2,1 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-01","regulatory_area_zh":"长度","search_zh":"分度值 0,01 mm 的模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-01","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,01 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 10 mm","cmc":"1,2 µm"},{"name":"","range":"10 mm to 100 mm","cmc":"2,1 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-01","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,01 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-01","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,01 mm"},{"_id":"64eb09f80684f9e64fadf951","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe o wartości działki elementarnej 0,1 mm","test_object_en":"Analogue dial gauges with a scale interval of 0,1 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 100 mm","cmc":"8,3 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"8,3 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 100 mm CMC 8,3 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-01","norm_bases":["IW-3-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe o wartości działki elementarnej 0,1 mm Wzorcowanie — Długość\n0 mm do 100 mm CMC 8,3 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-01 Czujniki analogowe o wartosci dzialki elementarnej 0,1 mm Wzorcowanie — Dlugosc\n0 mm do 100 mm CMC 8,3 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-01","search_en":"Analogue dial gauges with a scale interval of 0,1 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 100 mm","cmc":"8,3 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-01","regulatory_area_de":"Länge","search_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,1 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-01","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Messuhren mit einem Skalenteilungswert von 0,1 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 100 mm","cmc":"8,3 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-01","regulatory_area_zh":"长度","search_zh":"分度值 0,1 mm 的模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-01","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,1 mm 的模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 100 mm","cmc":"8,3 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-01","regulatory_area_cs":"Délka","search_cs":"Analogové úchylkoměry s hodnotou dílku 0,1 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-01","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové úchylkoměry s hodnotou dílku 0,1 mm"},{"_id":"60250a7405fbc860790e3152","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,0002 mm","test_object_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,0002 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10 mm","cmc":"0,5 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 10 mm CMC 0,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,0002 mm Wzorcowanie — Długość\n0 mm do 10 mm CMC 0,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczosci 0,0002 mm Wzorcowanie — Dlugosc\n0 mm do 10 mm CMC 0,5 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,0002 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 10 mm","cmc":"0,5 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,0002 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,0002 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 10 mm","cmc":"0,5 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,0002 mm 的数显指示表及数显扭簧比较仪型测微表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,0002 mm 的数显指示表及数显扭簧比较仪型测微表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 10 mm","cmc":"0,5 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,0002 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,0002 mm"},{"_id":"6aa6c19ed93ea2f8c61c255c","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,0002 mm","test_object_en":"Digital dial gauges with a resolution of 0,0002 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 100 mm","cmc":"0,7 µm"}],"parameters_en":[{"name":"","range":"10 mm to 100 mm","cmc":"0,7 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n10 mm do 100 mm CMC 0,7 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,0002 mm Wzorcowanie — Długość\n10 mm do 100 mm CMC 0,7 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe o rozdzielczosci 0,0002 mm Wzorcowanie — Dlugosc\n10 mm do 100 mm CMC 0,7 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges with a resolution of 0,0002 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 100 mm","cmc":"0,7 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,0002 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,0002 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 100 mm","cmc":"0,7 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,0002 mm 的数显指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,0002 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 100 mm","cmc":"0,7 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,0002 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,0002 mm"},{"_id":"daa3e32186b3bd25431794d0","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,0005 mm","test_object_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,0005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"0,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10 mm","cmc":"0,6 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 10 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,0005 mm Wzorcowanie — Długość\n0 mm do 10 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczosci 0,0005 mm Wzorcowanie — Dlugosc\n0 mm do 10 mm CMC 0,6 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,0005 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 10 mm","cmc":"0,6 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,0005 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,0005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 10 mm","cmc":"0,6 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,0005 mm 的数显指示表及数显扭簧比较仪型测微表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,0005 mm 的数显指示表及数显扭簧比较仪型测微表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 10 mm","cmc":"0,6 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,0005 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,0005 mm"},{"_id":"7fcf9e650d238585f4b86ac6","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,0005 mm","test_object_en":"Digital dial gauges with a resolution of 0,0005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 100 mm","cmc":"0,8 µm"}],"parameters_en":[{"name":"","range":"10 mm to 100 mm","cmc":"0,8 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n10 mm do 100 mm CMC 0,8 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,0005 mm Wzorcowanie — Długość\n10 mm do 100 mm CMC 0,8 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe o rozdzielczosci 0,0005 mm Wzorcowanie — Dlugosc\n10 mm do 100 mm CMC 0,8 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges with a resolution of 0,0005 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 100 mm","cmc":"0,8 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,0005 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,0005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 100 mm","cmc":"0,8 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,0005 mm 的数显指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,0005 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 100 mm","cmc":"0,8 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,0005 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,0005 mm"},{"_id":"5dca7c5f6bf54447bf3eadd3","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,001 mm","test_object_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"0,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10 mm","cmc":"0,6 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 10 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,001 mm Wzorcowanie — Długość\n0 mm do 10 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczosci 0,001 mm Wzorcowanie — Dlugosc\n0 mm do 10 mm CMC 0,6 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,001 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 10 mm","cmc":"0,6 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,001 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 10 mm","cmc":"0,6 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,001 mm 的数显指示表及数显扭簧比较仪型测微表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,001 mm 的数显指示表及数显扭簧比较仪型测微表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 10 mm","cmc":"0,6 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,001 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,001 mm"},{"_id":"d08c0c31ac9792f4a2e42658","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,001 mm","test_object_en":"Digital dial gauges with a resolution of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 100 mm","cmc":"1,5 µm"}],"parameters_en":[{"name":"","range":"10 mm to 100 mm","cmc":"1,5 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n10 mm do 100 mm CMC 1,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,001 mm Wzorcowanie — Długość\n10 mm do 100 mm CMC 1,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe o rozdzielczosci 0,001 mm Wzorcowanie — Dlugosc\n10 mm do 100 mm CMC 1,5 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges with a resolution of 0,001 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 100 mm","cmc":"1,5 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,001 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 100 mm","cmc":"1,5 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,001 mm 的数显指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,001 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 100 mm","cmc":"1,5 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,001 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,001 mm"},{"_id":"dd21f75759c23327ee737569","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,002 mm","test_object_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,002 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"1,3 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10 mm","cmc":"1,3 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 10 mm CMC 1,3 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,002 mm Wzorcowanie — Długość\n0 mm do 10 mm CMC 1,3 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczosci 0,002 mm Wzorcowanie — Dlugosc\n0 mm do 10 mm CMC 1,3 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,002 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":19,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 10 mm","cmc":"1,3 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,002 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,002 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 10 mm","cmc":"1,3 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,002 mm 的数显指示表及数显扭簧比较仪型测微表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,002 mm 的数显指示表及数显扭簧比较仪型测微表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 10 mm","cmc":"1,3 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,002 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,002 mm"},{"_id":"3945b48d316d3a0ed6f2e4fa","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,002 mm","test_object_en":"Digital dial gauges with a resolution of 0,002 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 100 mm","cmc":"1,4 µm"}],"parameters_en":[{"name":"","range":"10 mm to 100 mm","cmc":"1,4 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n10 mm do 100 mm CMC 1,4 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,002 mm Wzorcowanie — Długość\n10 mm do 100 mm CMC 1,4 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe o rozdzielczosci 0,002 mm Wzorcowanie — Dlugosc\n10 mm do 100 mm CMC 1,4 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges with a resolution of 0,002 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":20,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 100 mm","cmc":"1,4 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,002 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,002 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 100 mm","cmc":"1,4 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,002 mm 的数显指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,002 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 100 mm","cmc":"1,4 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,002 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,002 mm"},{"_id":"166bba044125fd9fae359214","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,005 mm","test_object_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"1,3 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10 mm","cmc":"1,3 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 10 mm CMC 1,3 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,005 mm Wzorcowanie — Długość\n0 mm do 10 mm CMC 1,3 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczosci 0,005 mm Wzorcowanie — Dlugosc\n0 mm do 10 mm CMC 1,3 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,005 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":21,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 10 mm","cmc":"1,3 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,005 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 10 mm","cmc":"1,3 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,005 mm 的数显指示表及数显扭簧比较仪型测微表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,005 mm 的数显指示表及数显扭簧比较仪型测微表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 10 mm","cmc":"1,3 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,005 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,005 mm"},{"_id":"16b06c9ba3cd031603da299b","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,005 mm","test_object_en":"Digital dial gauges with a resolution of 0,005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 100 mm","cmc":"1,4 µm"}],"parameters_en":[{"name":"","range":"10 mm to 100 mm","cmc":"1,4 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n10 mm do 100 mm CMC 1,4 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,005 mm Wzorcowanie — Długość\n10 mm do 100 mm CMC 1,4 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe o rozdzielczosci 0,005 mm Wzorcowanie — Dlugosc\n10 mm do 100 mm CMC 1,4 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges with a resolution of 0,005 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":22,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 100 mm","cmc":"1,4 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,005 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 100 mm","cmc":"1,4 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,005 mm 的数显指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,005 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 100 mm","cmc":"1,4 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,005 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,005 mm"},{"_id":"a9755d88c0148f15dfe47165","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,01 mm","test_object_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"1,8 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10 mm","cmc":"1,8 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 10 mm CMC 1,8 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,01 mm Wzorcowanie — Długość\n0 mm do 10 mm CMC 1,8 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczosci 0,01 mm Wzorcowanie — Dlugosc\n0 mm do 10 mm CMC 1,8 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,01 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":23,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 10 mm","cmc":"1,8 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,01 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 10 mm","cmc":"1,8 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,01 mm 的数显指示表及数显扭簧比较仪型测微表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,01 mm 的数显指示表及数显扭簧比较仪型测微表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 10 mm","cmc":"1,8 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,01 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,01 mm"},{"_id":"92043305a77858f702a1d096","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,01 mm","test_object_en":"Digital dial gauges with a resolution of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 100 mm","cmc":"2,1 µm"}],"parameters_en":[{"name":"","range":"10 mm to 100 mm","cmc":"2,1 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n10 mm do 100 mm CMC 2,1 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,01 mm Wzorcowanie — Długość\n10 mm do 100 mm CMC 2,1 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe o rozdzielczosci 0,01 mm Wzorcowanie — Dlugosc\n10 mm do 100 mm CMC 2,1 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges with a resolution of 0,01 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":24,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 100 mm","cmc":"2,1 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messtaster mit einer Auflösung von 0,01 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messtaster mit einer Auflösung von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 100 mm","cmc":"2,1 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨率 0,01 mm 的数字测微表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨率 0,01 mm 的数字测微表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 100 mm","cmc":"2,1 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,01 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,01 mm"},{"_id":"6250f607cac2a1383c512e6e","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,02 mm","test_object_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,02 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 10 mm","cmc":"5,8 µm"}],"parameters_en":[{"name":"","range":"0 mm to 10 mm","cmc":"5,8 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 10 mm CMC 5,8 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczości 0,02 mm Wzorcowanie — Długość\n0 mm do 10 mm CMC 5,8 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe oraz czujniki cyfrowe typu mikrokator o rozdzielczosci 0,02 mm Wzorcowanie — Dlugosc\n0 mm do 10 mm CMC 5,8 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges and digital micrometer-type gauges with a resolution of 0,02 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":25,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 10 mm","cmc":"5,8 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,02 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren und digitale Feinzeiger (Mikrokator) mit einer Auflösung von 0,02 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 10 mm","cmc":"5,8 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,02 mm 的数显指示表及数显扭簧比较仪型测微表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,02 mm 的数显指示表及数显扭簧比较仪型测微表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 10 mm","cmc":"5,8 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,02 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry a digitální úchylkoměry typu mikrokátor s rozlišením 0,02 mm"},{"_id":"5333d502662ccb36ed685047","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,02 mm","test_object_en":"Digital dial gauges with a resolution of 0,02 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 100 mm","cmc":"5,9 µm"}],"parameters_en":[{"name":"","range":"10 mm to 100 mm","cmc":"5,9 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n10 mm do 100 mm CMC 5,9 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,02 mm Wzorcowanie — Długość\n10 mm do 100 mm CMC 5,9 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe o rozdzielczosci 0,02 mm Wzorcowanie — Dlugosc\n10 mm do 100 mm CMC 5,9 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges with a resolution of 0,02 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":26,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 100 mm","cmc":"5,9 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,02 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,02 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 100 mm","cmc":"5,9 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,02 mm 的数显指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,02 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 100 mm","cmc":"5,9 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,02 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,02 mm"},{"_id":"88fbabd5d739978729baa2df","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,05 mm","test_object_en":"Digital dial gauges with a resolution of 0,05 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 100 mm","cmc":"14,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"14,5 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 100 mm CMC 14,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,05 mm Wzorcowanie — Długość\n0 mm do 100 mm CMC 14,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe o rozdzielczosci 0,05 mm Wzorcowanie — Dlugosc\n0 mm do 100 mm CMC 14,5 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges with a resolution of 0,05 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":27,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 100 mm","cmc":"14,5 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,05 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,05 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 100 mm","cmc":"14,5 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,05 mm 的数显指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,05 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 100 mm","cmc":"14,5 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,05 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,05 mm"},{"_id":"09c2a553f436629a3a9f8a29","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,1 mm","test_object_en":"Digital dial gauges with a resolution of 0,1 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 100 mm","cmc":"28,9 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"28,9 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 100 mm CMC 28,9 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,1 mm Wzorcowanie — Długość\n0 mm do 100 mm CMC 28,9 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe o rozdzielczosci 0,1 mm Wzorcowanie — Dlugosc\n0 mm do 100 mm CMC 28,9 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges with a resolution of 0,1 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":28,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 100 mm","cmc":"28,9 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,1 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,1 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 100 mm","cmc":"28,9 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,1 mm 的数显指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,1 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 100 mm","cmc":"28,9 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,1 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,1 mm"},{"_id":"ba7de2c24eb5211102f1c66e","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe o rozdzielczości 0,2 mm","test_object_en":"Digital dial gauges with a resolution of 0,2 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 100 mm","cmc":"57,8 µm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"57,8 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 100 mm CMC 57,8 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-02","norm_bases":["IW-3-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe o rozdzielczości 0,2 mm Wzorcowanie — Długość\n0 mm do 100 mm CMC 57,8 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-02 Czujniki cyfrowe o rozdzielczosci 0,2 mm Wzorcowanie — Dlugosc\n0 mm do 100 mm CMC 57,8 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-02","search_en":"Digital dial gauges with a resolution of 0,2 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":29,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 100 mm","cmc":"57,8 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-02","regulatory_area_de":"Länge","search_de":"Digitale Messuhren mit einer Auflösung von 0,2 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-02","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Messuhren mit einer Auflösung von 0,2 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 100 mm","cmc":"57,8 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-02","regulatory_area_zh":"长度","search_zh":"分辨力 0,2 mm 的数显指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-02","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,2 mm 的数显指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 100 mm","cmc":"57,8 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Digitální úchylkoměry s rozlišením 0,2 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-02","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální úchylkoměry s rozlišením 0,2 mm"},{"_id":"3aa40d3a46d88a100d3512fd","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,001 mm","test_object_en":"Lever-type analogue dial gauges with a scale interval of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 0,6 mm","cmc":"0,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,6 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 0,6 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-03","norm_bases":["IW-3-LW-AK-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,001 mm Wzorcowanie — Długość\n0 mm do 0,6 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-03 Czujniki analogowe z uchylnym trzpieniem o wartosci dzialki elementarnej 0,001 mm Wzorcowanie — Dlugosc\n0 mm do 0,6 mm CMC 0,6 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-03","search_en":"Lever-type analogue dial gauges with a scale interval of 0,001 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":30,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,6 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-03","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,001 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-03","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,6 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-03","regulatory_area_zh":"长度","search_zh":"分度值 0,001 mm 的模拟杠杆指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-03","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,001 mm 的模拟杠杆指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 0,6 mm","cmc":"0,6 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-03","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,001 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-03","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,001 mm"},{"_id":"ccd8d6acea063235329b22aa","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,002 mm","test_object_en":"Lever-type analogue dial gauges with a scale interval of 0,002 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 1,2 mm","cmc":"0,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 1,2 mm","cmc":"0,6 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 1,2 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-03","norm_bases":["IW-3-LW-AK-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,002 mm Wzorcowanie — Długość\n0 mm do 1,2 mm CMC 0,6 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-03 Czujniki analogowe z uchylnym trzpieniem o wartosci dzialki elementarnej 0,002 mm Wzorcowanie — Dlugosc\n0 mm do 1,2 mm CMC 0,6 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-03","search_en":"Lever-type analogue dial gauges with a scale interval of 0,002 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":31,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 1,2 mm","cmc":"0,6 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-03","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,002 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-03","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,002 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 1,2 mm","cmc":"0,6 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-03","regulatory_area_zh":"长度","search_zh":"分度值 0,002 mm的模拟式杠杆指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-03","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,002 mm的模拟式杠杆指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 1,2 mm","cmc":"0,6 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-03","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,002 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-03","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,002 mm"},{"_id":"3fc6d64a1686be88fa676b48","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,01 mm","test_object_en":"Lever-type analogue dial gauges with a scale interval of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 3 mm","cmc":"1,2 µm"}],"parameters_en":[{"name":"","range":"0 mm to 3 mm","cmc":"1,2 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 3 mm CMC 1,2 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-03","norm_bases":["IW-3-LW-AK-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,01 mm Wzorcowanie — Długość\n0 mm do 3 mm CMC 1,2 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-03 Czujniki analogowe z uchylnym trzpieniem o wartosci dzialki elementarnej 0,01 mm Wzorcowanie — Dlugosc\n0 mm do 3 mm CMC 1,2 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-03","search_en":"Lever-type analogue dial gauges with a scale interval of 0,01 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":32,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 3 mm","cmc":"1,2 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-03","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,01 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-03","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 3 mm","cmc":"1,2 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-03","regulatory_area_zh":"长度","search_zh":"分度值 0,01 mm的模拟式杠杆指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-03","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,01 mm的模拟式杠杆指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 3 mm","cmc":"1,2 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-03","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,01 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-03","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,01 mm"},{"_id":"4f2e5308ef6cb9204eb74cc5","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,02 mm","test_object_en":"Lever-type analogue dial gauges with a scale interval of 0,02 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 2 mm","cmc":"1,7 µm"}],"parameters_en":[{"name":"","range":"0 mm to 2 mm","cmc":"1,7 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 2 mm CMC 1,7 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-03","norm_bases":["IW-3-LW-AK-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe z uchylnym trzpieniem o wartości działki elementarnej 0,02 mm Wzorcowanie — Długość\n0 mm do 2 mm CMC 1,7 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-03 Czujniki analogowe z uchylnym trzpieniem o wartosci dzialki elementarnej 0,02 mm Wzorcowanie — Dlugosc\n0 mm do 2 mm CMC 1,7 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-03","search_en":"Lever-type analogue dial gauges with a scale interval of 0,02 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":33,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 2 mm","cmc":"1,7 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-03","regulatory_area_de":"Länge","search_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,02 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-03","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Fühlhebelmessgeräte mit einem Skalenteilungswert von 0,02 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 2 mm","cmc":"1,7 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-03","regulatory_area_zh":"长度","search_zh":"分度值 0,02 mm 的模拟杠杆指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-03","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,02 mm 的模拟杠杆指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 2 mm","cmc":"1,7 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-03","regulatory_area_cs":"Délka","search_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,02 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-03","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové páčkové úchylkoměry s hodnotou dílku 0,02 mm"},{"_id":"0cda1e3d5290580bd820d089","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe z uchylnym trzpieniem o rozdzielczości 0,001 mm","test_object_en":"Lever-type digital dial gauges with a resolution of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 2 mm","cmc":"0,7 µm"}],"parameters_en":[{"name":"","range":"0 mm to 2 mm","cmc":"0,7 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 2 mm CMC 0,7 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-04","norm_bases":["IW-3-LW-AK-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe z uchylnym trzpieniem o rozdzielczości 0,001 mm Wzorcowanie — Długość\n0 mm do 2 mm CMC 0,7 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-04 Czujniki cyfrowe z uchylnym trzpieniem o rozdzielczosci 0,001 mm Wzorcowanie — Dlugosc\n0 mm do 2 mm CMC 0,7 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-04","search_en":"Lever-type digital dial gauges with a resolution of 0,001 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":34,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-04","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 2 mm","cmc":"0,7 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-04","regulatory_area_de":"Länge","search_de":"Digitale Fühlhebelmessgeräte mit einer Auflösung von 0,001 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-04","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Fühlhebelmessgeräte mit einer Auflösung von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 2 mm","cmc":"0,7 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-04","regulatory_area_zh":"长度","search_zh":"分辨力 0,001 mm 的数显杠杆指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-04","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,001 mm 的数显杠杆指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 2 mm","cmc":"0,7 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-04","regulatory_area_cs":"Délka","search_cs":"Digitální páčkové úchylkoměry s rozlišením 0,001 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-04","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální páčkové úchylkoměry s rozlišením 0,001 mm"},{"_id":"470c16159fb6e18360171cdb","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki cyfrowe z uchylnym trzpieniem o rozdzielczości 0,01 mm","test_object_en":"Lever-type digital dial gauges with a resolution of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 2 mm","cmc":"1,2 µm"}],"parameters_en":[{"name":"","range":"0 mm to 2 mm","cmc":"1,2 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 2 mm CMC 1,2 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-04","norm_bases":["IW-3-LW-AK-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki cyfrowe z uchylnym trzpieniem o rozdzielczości 0,01 mm Wzorcowanie — Długość\n0 mm do 2 mm CMC 1,2 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-04 Czujniki cyfrowe z uchylnym trzpieniem o rozdzielczosci 0,01 mm Wzorcowanie — Dlugosc\n0 mm do 2 mm CMC 1,2 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-04","search_en":"Lever-type digital dial gauges with a resolution of 0,01 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":35,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-04","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 2 mm","cmc":"1,2 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-04","regulatory_area_de":"Länge","search_de":"Digitale Fühlhebelmessgeräte mit einer Auflösung von 0,01 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-04","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Digitale Fühlhebelmessgeräte mit einer Auflösung von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 2 mm","cmc":"1,2 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-04","regulatory_area_zh":"长度","search_zh":"分辨力 0,01 mm 的数显杠杆指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-04","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分辨力 0,01 mm 的数显杠杆指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 2 mm","cmc":"1,2 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-04","regulatory_area_cs":"Délka","search_cs":"Digitální páčkové úchylkoměry s rozlišením 0,01 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-04","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální páčkové úchylkoměry s rozlišením 0,01 mm"},{"_id":"31ce2b2b70c786716d0e5369","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,0002 mm","test_object_en":"Lever-gear analogue dial gauges with a scale interval of 0,0002 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"-0,015 mm do 0,015 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"-0,015 mm to 0,015 mm","cmc":"0,5 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n-0,015 mm do 0,015 mm CMC 0,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-05","norm_bases":["IW-3-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,0002 mm Wzorcowanie — Długość\n-0,015 mm do 0,015 mm CMC 0,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-05 Czujniki analogowe dzwigniowo-zebate o wartosci dzialki elementarnej 0,0002 mm Wzorcowanie — Dlugosc\n-0,015 mm do 0,015 mm CMC 0,5 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-05","search_en":"Lever-gear analogue dial gauges with a scale interval of 0,0002 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":36,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"-0,015 mm to 0,015 mm","cmc":"0,5 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-05","regulatory_area_de":"Länge","search_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,0002 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-05","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,0002 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"-0,015 mm to 0,015 mm","cmc":"0,5 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-05","regulatory_area_zh":"长度","search_zh":"分度值 0,0002 mm 的杠杆齿轮式模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-05","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,0002 mm 的杠杆齿轮式模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"-0,015 mm to 0,015 mm","cmc":"0,5 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,0002 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-05","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,0002 mm"},{"_id":"6ab80385fad6761df7771c9a","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,0005 mm","test_object_en":"Lever-gear analogue dial gauges with a scale interval of 0,0005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"-0,025 mm do 0,025 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"-0,025 mm to 0,025 mm","cmc":"0,5 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n-0,025 mm do 0,025 mm CMC 0,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-05","norm_bases":["IW-3-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,0005 mm Wzorcowanie — Długość\n-0,025 mm do 0,025 mm CMC 0,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-05 Czujniki analogowe dzwigniowo-zebate o wartosci dzialki elementarnej 0,0005 mm Wzorcowanie — Dlugosc\n-0,025 mm do 0,025 mm CMC 0,5 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-05","search_en":"Lever-gear analogue dial gauges with a scale interval of 0,0005 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":37,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"-0,025 mm to 0,025 mm","cmc":"0,5 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-05","regulatory_area_de":"Länge","search_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,0005 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-05","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,0005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"-0,025 mm to 0,025 mm","cmc":"0,5 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-05","regulatory_area_zh":"长度","search_zh":"分度值 0,0005 mm 的杠杆齿轮式模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-05","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,0005 mm 的杠杆齿轮式模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"-0,025 mm to 0,025 mm","cmc":"0,5 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,0005 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-05","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,0005 mm"},{"_id":"70701afc218fb6ad09d4685b","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,001 mm","test_object_en":"Lever-gear analogue dial gauges with a scale interval of 0,001 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"-0,10 mm do 0,10 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"-0,10 mm to 0,10 mm","cmc":"0,5 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n-0,10 mm do 0,10 mm CMC 0,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-05","norm_bases":["IW-3-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,001 mm Wzorcowanie — Długość\n-0,10 mm do 0,10 mm CMC 0,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-05 Czujniki analogowe dzwigniowo-zebate o wartosci dzialki elementarnej 0,001 mm Wzorcowanie — Dlugosc\n-0,10 mm do 0,10 mm CMC 0,5 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-05","search_en":"Lever-gear analogue dial gauges with a scale interval of 0,001 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":38,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"-0,10 mm to 0,10 mm","cmc":"0,5 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-05","regulatory_area_de":"Länge","search_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,001 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-05","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,001 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"-0,10 mm to 0,10 mm","cmc":"0,5 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-05","regulatory_area_zh":"长度","search_zh":"分度值 0,001 mm 的杠杆齿轮式模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-05","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,001 mm 的杠杆齿轮式模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"-0,10 mm to 0,10 mm","cmc":"0,5 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,001 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-05","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,001 mm"},{"_id":"b64593e3f88fe9ad69a83346","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,002 mm","test_object_en":"Lever-gear analogue dial gauges with a scale interval of 0,002 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"-0,13 mm do 0,13 mm","cmc":"0,5 µm"}],"parameters_en":[{"name":"","range":"-0,13 mm to 0,13 mm","cmc":"0,5 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n-0,13 mm do 0,13 mm CMC 0,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-05","norm_bases":["IW-3-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,002 mm Wzorcowanie — Długość\n-0,13 mm do 0,13 mm CMC 0,5 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-05 Czujniki analogowe dzwigniowo-zebate o wartosci dzialki elementarnej 0,002 mm Wzorcowanie — Dlugosc\n-0,13 mm do 0,13 mm CMC 0,5 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-05","search_en":"Lever-gear analogue dial gauges with a scale interval of 0,002 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":39,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"-0,13 mm to 0,13 mm","cmc":"0,5 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-05","regulatory_area_de":"Länge","search_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,002 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-05","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,002 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"-0,13 mm to 0,13 mm","cmc":"0,5 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-05","regulatory_area_zh":"长度","search_zh":"分度值 0,002 mm 的杠杆齿轮式模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-05","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,002 mm 的杠杆齿轮式模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"-0,13 mm to 0,13 mm","cmc":"0,5 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,002 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-05","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,002 mm"},{"_id":"091bb070e0dbb7341f42ffed","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,005 mm","test_object_en":"Lever-gear analogue dial gauges with a scale interval of 0,005 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"-0,20 mm do 0,20 mm","cmc":"0,7 µm"}],"parameters_en":[{"name":"","range":"-0,20 mm to 0,20 mm","cmc":"0,7 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n-0,20 mm do 0,20 mm CMC 0,7 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-05","norm_bases":["IW-3-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,005 mm Wzorcowanie — Długość\n-0,20 mm do 0,20 mm CMC 0,7 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-05 Czujniki analogowe dzwigniowo-zebate o wartosci dzialki elementarnej 0,005 mm Wzorcowanie — Dlugosc\n-0,20 mm do 0,20 mm CMC 0,7 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-05","search_en":"Lever-gear analogue dial gauges with a scale interval of 0,005 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":40,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"-0,20 mm to 0,20 mm","cmc":"0,7 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-05","regulatory_area_de":"Länge","search_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,005 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-05","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,005 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"-0,20 mm to 0,20 mm","cmc":"0,7 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-05","regulatory_area_zh":"长度","search_zh":"分度值 0,005 mm 的杠杆齿轮式模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-05","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,005 mm 的杠杆齿轮式模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"-0,20 mm to 0,20 mm","cmc":"0,7 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,005 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-05","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,005 mm"},{"_id":"616ed075d4685ea446daf014","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,01 mm","test_object_en":"Lever-gear analogue dial gauges with a scale interval of 0,01 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"-1,0 mm do 1,0 mm","cmc":"1,0 µm"}],"parameters_en":[{"name":"","range":"-1,0 mm to 1,0 mm","cmc":"1,0 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n-1,0 mm do 1,0 mm CMC 1,0 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-05","norm_bases":["IW-3-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,01 mm Wzorcowanie — Długość\n-1,0 mm do 1,0 mm CMC 1,0 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-05 Czujniki analogowe dzwigniowo-zebate o wartosci dzialki elementarnej 0,01 mm Wzorcowanie — Dlugosc\n-1,0 mm do 1,0 mm CMC 1,0 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-05","search_en":"Lever-gear analogue dial gauges with a scale interval of 0,01 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":41,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"-1,0 mm to 1,0 mm","cmc":"1,0 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-05","regulatory_area_de":"Länge","search_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,01 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-05","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,01 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"-1,0 mm to 1,0 mm","cmc":"1,0 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-05","regulatory_area_zh":"长度","search_zh":"分度值 0,01 mm 的杠杆齿轮式模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-05","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,01 mm 的杠杆齿轮式模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"-1,0 mm to 1,0 mm","cmc":"1,0 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,01 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-05","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,01 mm"},{"_id":"787ed1376bc2fd08e782a97d","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,05 mm","test_object_en":"Lever-gear analogue dial gauges with a scale interval of 0,05 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"-1,5 mm do 1,5 mm","cmc":"4,1 µm"}],"parameters_en":[{"name":"","range":"-1,5 mm to 1,5 mm","cmc":"4,1 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n-1,5 mm do 1,5 mm CMC 4,1 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-05","norm_bases":["IW-3-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,05 mm Wzorcowanie — Długość\n-1,5 mm do 1,5 mm CMC 4,1 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-05 Czujniki analogowe dzwigniowo-zebate o wartosci dzialki elementarnej 0,05 mm Wzorcowanie — Dlugosc\n-1,5 mm do 1,5 mm CMC 4,1 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-05","search_en":"Lever-gear analogue dial gauges with a scale interval of 0,05 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":42,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"-1,5 mm to 1,5 mm","cmc":"4,1 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-05","regulatory_area_de":"Länge","search_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,05 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-05","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,05 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"-1,5 mm to 1,5 mm","cmc":"4,1 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-05","regulatory_area_zh":"长度","search_zh":"分度值 0,05 mm 的杠杆齿轮式模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-05","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,05 mm 的杠杆齿轮式模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"-1,5 mm to 1,5 mm","cmc":"4,1 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,05 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-05","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,05 mm"},{"_id":"6ab1fd9a65d8ab4384402ae3","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,1 mm","test_object_en":"Lever-gear analogue dial gauges with a scale interval of 0,1 mm","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"-4,0 mm do 4,0 mm","cmc":"8,2 µm"}],"parameters_en":[{"name":"","range":"-4,0 mm to 4,0 mm","cmc":"8,2 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n-4,0 mm do 4,0 mm CMC 8,2 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-3-LW-AK-05","norm_bases":["IW-3-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki analogowe dźwigniowo-zębate o wartości działki elementarnej 0,1 mm Wzorcowanie — Długość\n-4,0 mm do 4,0 mm CMC 8,2 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR; W stałej lokalizacji (S) Procedura wewnętrzna IW-3-LW-AK-05 Czujniki analogowe dzwigniowo-zebate o wartosci dzialki elementarnej 0,1 mm Wzorcowanie — Dlugosc\n-4,0 mm do 4,0 mm CMC 8,2 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR; W stalej lokalizacji (S) Procedura wewnetrzna IW-3-LW-AK-05","search_en":"Lever-gear analogue dial gauges with a scale interval of 0,1 mm Calibration — Length Internal procedure; using OPTIMAR; At permanent location (S) Length Internal procedure using OPTIMAR At permanent location (S) Internal procedure IW-3-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":43,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-3-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"-4,0 mm to 4,0 mm","cmc":"8,2 µm"}],"reference_de":"Internes Verfahren IW-3-LW-AK-05","regulatory_area_de":"Länge","search_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,1 mm Kalibrierung — Länge Internes Verfahren; mit OPTIMAR; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR Am festen Standort (S) Internes Verfahren IW-3-LW-AK-05","technique_de":"Internes Verfahren; mit OPTIMAR; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR","Am festen Standort (S)"],"test_object_de":"Analoge Hebel-Zahnrad-Messuhren mit einem Skalenteilungswert von 0,1 mm","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"-4,0 mm to 4,0 mm","cmc":"8,2 µm"}],"reference_zh":"内部程序 IW-3-LW-AK-05","regulatory_area_zh":"长度","search_zh":"分度值 0,1 mm 的杠杆齿轮式模拟指示表 校准 — 长度 内部程序；使用OPTIMAR；在固定地点 (S) 长度 内部程序 使用OPTIMAR 在固定地点 (S) 内部程序 IW-3-LW-AK-05","technique_zh":"内部程序；使用OPTIMAR；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR","在固定地点 (S)"],"test_object_zh":"分度值 0,1 mm 的杠杆齿轮式模拟指示表","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"-4,0 mm to 4,0 mm","cmc":"8,2 µm"}],"reference_cs":"Vnitřní postup IW-3-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,1 mm Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR Ve stálé lokalitě (S) Vnitřní postup IW-3-LW-AK-05","technique_cs":"Vnitřní postup; pomocí OPTIMAR; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové pákové úchylkoměry s ozubeným převodem s hodnotou dílku 0,1 mm"},{"_id":"1eb313e3eabc197e5c740817","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Średnicówki mikrometryczne dwupunktowe i trójpunktowe","test_object_en":"Two-point and three-point inside micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"2 mm do 100 mm","cmc":"2,3 µm"},{"name":"","range":"100 mm do 300 mm","cmc":"2,8 µm"}],"parameters_en":[{"name":"","range":"2 mm to 100 mm","cmc":"2,3 µm"},{"name":"","range":"100 mm to 300 mm","cmc":"2,8 µm"}],"technique":"Procedura wewnętrzna; przy użyciu pierścieni wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using setting rings; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu pierścieni wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using setting rings","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n2 mm do 100 mm CMC 2,3 µm\n100 mm do 300 mm CMC 2,8 µm\nProcedura wewnętrzna; przy użyciu pierścieni wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-8-LW-AK-01","norm_bases":["IW-8-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki mikrometryczne dwupunktowe i trójpunktowe Wzorcowanie — Długość\nZakres:\n2 mm do 100 mm CMC 2,3 µm\n100 mm do 300 mm CMC 2,8 µm\nProcedura wewnętrzna; przy użyciu pierścieni wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-8-LW-AK-01 Srednicowki mikrometryczne dwupunktowe i trojpunktowe Wzorcowanie — Dlugosc\nZakres:\n2 mm do 100 mm CMC 2,3 µm\n100 mm do 300 mm CMC 2,8 µm\nProcedura wewnetrzna; przy uzyciu pierscieni wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-8-LW-AK-01","search_en":"Two-point and three-point inside micrometers Calibration — Length Internal procedure; using setting rings; At permanent location (S) Length Internal procedure using setting rings At permanent location (S) Internal procedure IW-8-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":44,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-8-LW-AK-01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"2 mm to 100 mm","cmc":"2,3 µm"},{"name":"","range":"100 mm to 300 mm","cmc":"2,8 µm"}],"reference_de":"Internes Verfahren IW-8-LW-AK-01","regulatory_area_de":"Länge","search_de":"Zwei- und Dreipunkt-Innenmessschrauben Kalibrierung — Länge Internes Verfahren; mit Einstellringen; Am festen Standort (S) Länge Internes Verfahren mit Einstellringen Am festen Standort (S) Internes Verfahren IW-8-LW-AK-01","technique_de":"Internes Verfahren; mit Einstellringen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Einstellringen","Am festen Standort (S)"],"test_object_de":"Zwei- und Dreipunkt-Innenmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"2 mm to 100 mm","cmc":"2,3 µm"},{"name":"","range":"100 mm to 300 mm","cmc":"2,8 µm"}],"reference_zh":"内部程序 IW-8-LW-AK-01","regulatory_area_zh":"长度","search_zh":"两点式和三点式内径千分尺 校准 — 长度 内部程序；使用校对环规；在固定地点 (S) 长度 内部程序 使用校对环规 在固定地点 (S) 内部程序 IW-8-LW-AK-01","technique_zh":"内部程序；使用校对环规；在固定地点 (S)","techniques_zh":["内部程序","使用校对环规","在固定地点 (S)"],"test_object_zh":"两点式和三点式内径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"2 mm to 100 mm","cmc":"2,3 µm"},{"name":"","range":"100 mm to 300 mm","cmc":"2,8 µm"}],"reference_cs":"Vnitřní postup IW-8-LW-AK-01","regulatory_area_cs":"Délka","search_cs":"Dvoudotekové a třídotekové mikrometrické dutinoměry Kalibrace — Délka Vnitřní postup; pomocí nastavovacích kroužků; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí nastavovacích kroužků Ve stálé lokalitě (S) Vnitřní postup IW-8-LW-AK-01","technique_cs":"Vnitřní postup; pomocí nastavovacích kroužků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí nastavovacích kroužků","Ve stálé lokalitě (S)"],"test_object_cs":"Dvoudotekové a třídotekové mikrometrické dutinoměry"},{"_id":"ccd17f55dfe395aa42a81141","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Sita","test_object_en":"Test sieves","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,02 mm do 25 mm","cmc":"4 µm"},{"name":"","range":"25 mm do 125 mm","cmc":"8 µm"}],"parameters_en":[{"name":"","range":"0,02 mm to 25 mm","cmc":"4 µm"},{"name":"","range":"25 mm to 125 mm","cmc":"8 µm"}],"technique":"Procedura wewnętrzna; pomiar przy użyciu współrzędnościowej maszyny pomiarowej; W stałej lokalizacji (S)","technique_en":"Internal procedure; measurement using a coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","pomiar przy użyciu współrzędnościowej maszyny pomiarowej","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","measurement using a coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0,02 mm do 25 mm CMC 4 µm\n25 mm do 125 mm CMC 8 µm\nProcedura wewnętrzna; pomiar przy użyciu współrzędnościowej maszyny pomiarowej; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-02 w oparciu o PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24","norm_bases":["IW-9-LW-AK-02","PN-ISO 3310-1:2000","PN-ISO 3310-2:2000","PN-ISO 3310-3:2000","PN-EN 933-3:2012","ASTM E11-24"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sita Wzorcowanie — Długość\nZakres:\n0,02 mm do 25 mm CMC 4 µm\n25 mm do 125 mm CMC 8 µm\nProcedura wewnętrzna; pomiar przy użyciu współrzędnościowej maszyny pomiarowej; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-02 w oparciu o PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24 Sita Wzorcowanie — Dlugosc\nZakres:\n0,02 mm do 25 mm CMC 4 µm\n25 mm do 125 mm CMC 8 µm\nProcedura wewnetrzna; pomiar przy uzyciu wspolrzednosciowej maszyny pomiarowej; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-02 w oparciu o PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24","search_en":"Test sieves Calibration — Length Internal procedure; measurement using a coordinate measuring machine; At permanent location (S) Length Internal procedure measurement using a coordinate measuring machine At permanent location (S) Internal procedure IW-9-LW-AK-02 based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":45,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-02 based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,02 mm to 25 mm","cmc":"4 µm"},{"name":"","range":"25 mm to 125 mm","cmc":"8 µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-02 auf Grundlage von PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24","regulatory_area_de":"Länge","search_de":"Prüfsiebe Kalibrierung — Länge Internes Verfahren; Messung mit einem Koordinatenmessgerät; Am festen Standort (S) Länge Internes Verfahren Messung mit einem Koordinatenmessgerät Am festen Standort (S) Internes Verfahren IW-9-LW-AK-02 auf Grundlage von PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24","technique_de":"Internes Verfahren; Messung mit einem Koordinatenmessgerät; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung mit einem Koordinatenmessgerät","Am festen Standort (S)"],"test_object_de":"Prüfsiebe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,02 mm to 25 mm","cmc":"4 µm"},{"name":"","range":"25 mm to 125 mm","cmc":"8 µm"}],"reference_zh":"内部程序 IW-9-LW-AK-02 依据PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24","regulatory_area_zh":"长度","search_zh":"试验筛 校准 — 长度 内部程序；使用坐标测量机测量；在固定地点 (S) 长度 内部程序 使用坐标测量机测量 在固定地点 (S) 内部程序 IW-9-LW-AK-02 依据PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24","technique_zh":"内部程序；使用坐标测量机测量；在固定地点 (S)","techniques_zh":["内部程序","使用坐标测量机测量","在固定地点 (S)"],"test_object_zh":"试验筛","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,02 mm to 25 mm","cmc":"4 µm"},{"name":"","range":"25 mm to 125 mm","cmc":"8 µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-02 na základě PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24","regulatory_area_cs":"Délka","search_cs":"Zkušební síta Kalibrace — Délka Vnitřní postup; měření pomocí souřadnicového měřicího stroje; Ve stálé lokalitě (S) Délka Vnitřní postup měření pomocí souřadnicového měřicího stroje Ve stálé lokalitě (S) Vnitřní postup IW-9-LW-AK-02 na základě PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 PN-ISO 3310-3:2000 PN-EN 933-3:2012 ASTM E11-24","technique_cs":"Vnitřní postup; měření pomocí souřadnicového měřicího stroje; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","měření pomocí souřadnicového měřicího stroje","Ve stálé lokalitě (S)"],"test_object_cs":"Zkušební síta"},{"_id":"58fa3a78ac3b6908f217f810","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Suwmiarki","test_object_en":"Vernier calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"22 µm"}],"parameters_en":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm to 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"20 µm"},{"name":"","range":"0 mm to 1000 mm","cmc":"22 µm"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 14 µm\n0 mm do 300 mm CMC 15 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 20 µm\n0 mm do 800 mm CMC 20 µm\n0 mm do 1000 mm CMC 22 µm\nW stałej lokalizacji (S)","reference":"PN-EN ISO 13385-1:2019","norm_bases":["PN-EN ISO 13385-1:2019"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Suwmiarki Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 14 µm\n0 mm do 300 mm CMC 15 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 20 µm\n0 mm do 800 mm CMC 20 µm\n0 mm do 1000 mm CMC 22 µm\nW stałej lokalizacji (S) PN-EN ISO 13385-1:2019 Suwmiarki Wzorcowanie — Dlugosc\nZakres:\n0 mm do 150 mm CMC 14 µm\n0 mm do 300 mm CMC 15 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 20 µm\n0 mm do 800 mm CMC 20 µm\n0 mm do 1000 mm CMC 22 µm\nW stalej lokalizacji (S) PN-EN ISO 13385-1:2019","search_en":"Vernier calipers Calibration — Length At permanent location (S) Length At permanent location (S) PN-EN ISO 13385-1:2019","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":46,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm bis 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"20 µm"},{"name":"","range":"0 mm bis 1000 mm","cmc":"22 µm"}],"regulatory_area_de":"Länge","search_de":"Messschieber Kalibrierung — Länge Am festen Standort (S) Länge Am festen Standort (S) PN-EN ISO 13385-1:2019","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Messschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm 至 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"20 µm"},{"name":"","range":"0 mm 至 1000 mm","cmc":"22 µm"}],"regulatory_area_zh":"长度","search_zh":"游标卡尺 校准 — 长度 在固定地点 (S) 长度 在固定地点 (S) PN-EN ISO 13385-1:2019","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"22 µm"}],"regulatory_area_cs":"Délka","search_cs":"Posuvná měřidla Kalibrace — Délka Ve stálé lokalitě (S) Délka Ve stálé lokalitě (S) PN-EN ISO 13385-1:2019","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Posuvná měřidla"},{"_id":"5e902b57a9a6d56ec30ed45d","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Wysokościomierze suwmiarkowe","test_object_en":"Vernier height gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"22 µm"}],"parameters_en":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm to 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"20 µm"},{"name":"","range":"0 mm to 1000 mm","cmc":"22 µm"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 14 µm\n0 mm do 300 mm CMC 15 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 20 µm\n0 mm do 800 mm CMC 20 µm\n0 mm do 1000 mm CMC 22 µm\nW stałej lokalizacji (S)","reference":"PN-EN ISO 13225-1:2020","norm_bases":["PN-EN ISO 13225-1:2020"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wysokościomierze suwmiarkowe Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 14 µm\n0 mm do 300 mm CMC 15 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 20 µm\n0 mm do 800 mm CMC 20 µm\n0 mm do 1000 mm CMC 22 µm\nW stałej lokalizacji (S) PN-EN ISO 13225-1:2020 Wysokosciomierze suwmiarkowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 150 mm CMC 14 µm\n0 mm do 300 mm CMC 15 µm\n0 mm do 500 mm CMC 17 µm\n0 mm do 600 mm CMC 20 µm\n0 mm do 800 mm CMC 20 µm\n0 mm do 1000 mm CMC 22 µm\nW stalej lokalizacji (S) PN-EN ISO 13225-1:2020","search_en":"Vernier height gauges Calibration — Length At permanent location (S) Length At permanent location (S) PN-EN ISO 13225-1:2020","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":47,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm bis 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"20 µm"},{"name":"","range":"0 mm bis 1000 mm","cmc":"22 µm"}],"regulatory_area_de":"Länge","search_de":"Höhenmessschieber Kalibrierung — Länge Am festen Standort (S) Länge Am festen Standort (S) PN-EN ISO 13225-1:2020","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Höhenmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm 至 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"20 µm"},{"name":"","range":"0 mm 至 1000 mm","cmc":"22 µm"}],"regulatory_area_zh":"长度","search_zh":"游标高度尺 校准 — 长度 在固定地点 (S) 长度 在固定地点 (S) PN-EN ISO 13225-1:2020","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"游标高度尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"},{"name":"","range":"0 mm do 600 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 800 mm","cmc":"20 µm"},{"name":"","range":"0 mm do 1000 mm","cmc":"22 µm"}],"regulatory_area_cs":"Délka","search_cs":"Posuvné výškoměry Kalibrace — Délka Ve stálé lokalitě (S) Délka Ve stálé lokalitě (S) PN-EN ISO 13225-1:2020","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Posuvné výškoměry"},{"_id":"d1cf2a59874a83c56805ce94","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Głębokościomierze suwmiarkowe","test_object_en":"Vernier depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm do 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm do 500 mm","cmc":"17 µm"}],"parameters_en":[{"name":"","range":"0 mm to 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm to 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm to 500 mm","cmc":"17 µm"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 14 µm\n0 mm do 300 mm CMC 15 µm\n0 mm do 500 mm CMC 17 µm\nW stałej lokalizacji (S)","reference":"PN-EN ISO 13385:2020","norm_bases":["PN-EN ISO 13385:2020"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze suwmiarkowe Wzorcowanie — Długość\nZakres:\n0 mm do 150 mm CMC 14 µm\n0 mm do 300 mm CMC 15 µm\n0 mm do 500 mm CMC 17 µm\nW stałej lokalizacji (S) PN-EN ISO 13385:2020 Glebokosciomierze suwmiarkowe Wzorcowanie — Dlugosc\nZakres:\n0 mm do 150 mm CMC 14 µm\n0 mm do 300 mm CMC 15 µm\n0 mm do 500 mm CMC 17 µm\nW stalej lokalizacji (S) PN-EN ISO 13385:2020","search_en":"Vernier depth gauges Calibration — Length At permanent location (S) Length At permanent location (S) PN-EN ISO 13385:2020","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":48,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm to 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm to 500 mm","cmc":"17 µm"}],"regulatory_area_de":"Länge","search_de":"Tiefenmessschieber Kalibrierung — Länge Am festen Standort (S) Länge Am festen Standort (S) PN-EN ISO 13385:2020","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Tiefenmessschieber","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm to 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm to 500 mm","cmc":"17 µm"}],"regulatory_area_zh":"长度","search_zh":"深度游标卡尺 校准 — 长度 在固定地点 (S) 长度 在固定地点 (S) PN-EN ISO 13385:2020","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"深度游标卡尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 150 mm","cmc":"14 µm"},{"name":"","range":"0 mm to 300 mm","cmc":"15 µm"},{"name":"","range":"0 mm to 500 mm","cmc":"17 µm"}],"regulatory_area_cs":"Délka","search_cs":"Posuvné hloubkoměry Kalibrace — Délka Ve stálé lokalitě (S) Délka Ve stálé lokalitě (S) PN-EN ISO 13385:2020","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Posuvné hloubkoměry"},{"_id":"d3e5038b176543fe39be7e26","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Mikrometry zewnętrzne","test_object_en":"External micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,1 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,1 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"4,7 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"5,1 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"5,4 µm"},{"name":"","range":"375 mm do 400 mm","cmc":"5,7 µm"},{"name":"","range":"400 mm do 425 mm","cmc":"6,1 µm"},{"name":"","range":"425 mm do 450 mm","cmc":"6,4 µm"},{"name":"","range":"450 mm do 475 mm","cmc":"6,8 µm"},{"name":"","range":"475 mm do 500 mm","cmc":"7,1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"2,1 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,1 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"4,7 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"5,1 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"5,4 µm"},{"name":"","range":"375 mm do 400 mm","cmc":"5,7 µm"},{"name":"","range":"400 mm do 425 mm","cmc":"6,1 µm"},{"name":"","range":"425 mm do 450 mm","cmc":"6,4 µm"},{"name":"","range":"450 mm do 475 mm","cmc":"6,8 µm"},{"name":"","range":"475 mm do 500 mm","cmc":"7,1 µm"}],"technique":"W stałej lokalizacji (S)","technique_en":"At permanent location (S)","techniques":["W stałej lokalizacji (S)"],"techniques_en":["At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,0 µm\n25 mm do 50 mm CMC 1,2 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,1 µm\n125 mm do 150 mm CMC 2,4 µm\n150 mm do 175 mm CMC 2,7 µm\n175 mm do 200 mm CMC 3,0 µm\n200 mm do 225 mm CMC 3,4 µm\n225 mm do 250 mm CMC 3,7 µm\n250 mm do 275 mm CMC 4,1 µm\n275 mm do 300 mm CMC 4,4 µm\n300 mm do 325 mm CMC 4,7 µm\n325 mm do 350 mm CMC 5,1 µm\n350 mm do 375 mm CMC 5,4 µm\n375 mm do 400 mm CMC 5,7 µm\n400 mm do 425 mm CMC 6,1 µm\n425 mm do 450 mm CMC 6,4 µm\n450 mm do 475 mm CMC 6,8 µm\n475 mm do 500 mm CMC 7,1 µm\nW stałej lokalizacji (S)","reference":"PN-EN ISO 3611:2023","norm_bases":["PN-EN ISO 3611:2023"],"internal_procedure":false,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry zewnętrzne Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,0 µm\n25 mm do 50 mm CMC 1,2 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,1 µm\n125 mm do 150 mm CMC 2,4 µm\n150 mm do 175 mm CMC 2,7 µm\n175 mm do 200 mm CMC 3,0 µm\n200 mm do 225 mm CMC 3,4 µm\n225 mm do 250 mm CMC 3,7 µm\n250 mm do 275 mm CMC 4,1 µm\n275 mm do 300 mm CMC 4,4 µm\n300 mm do 325 mm CMC 4,7 µm\n325 mm do 350 mm CMC 5,1 µm\n350 mm do 375 mm CMC 5,4 µm\n375 mm do 400 mm CMC 5,7 µm\n400 mm do 425 mm CMC 6,1 µm\n425 mm do 450 mm CMC 6,4 µm\n450 mm do 475 mm CMC 6,8 µm\n475 mm do 500 mm CMC 7,1 µm\nW stałej lokalizacji (S) PN-EN ISO 3611:2023 Mikrometry zewnetrzne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 25 mm CMC 1,0 µm\n25 mm do 50 mm CMC 1,2 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,1 µm\n125 mm do 150 mm CMC 2,4 µm\n150 mm do 175 mm CMC 2,7 µm\n175 mm do 200 mm CMC 3,0 µm\n200 mm do 225 mm CMC 3,4 µm\n225 mm do 250 mm CMC 3,7 µm\n250 mm do 275 mm CMC 4,1 µm\n275 mm do 300 mm CMC 4,4 µm\n300 mm do 325 mm CMC 4,7 µm\n325 mm do 350 mm CMC 5,1 µm\n350 mm do 375 mm CMC 5,4 µm\n375 mm do 400 mm CMC 5,7 µm\n400 mm do 425 mm CMC 6,1 µm\n425 mm do 450 mm CMC 6,4 µm\n450 mm do 475 mm CMC 6,8 µm\n475 mm do 500 mm CMC 7,1 µm\nW stalej lokalizacji (S) PN-EN ISO 3611:2023","search_en":"External micrometers Calibration — Length At permanent location (S) Length At permanent location (S) PN-EN ISO 3611:2023","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":49,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"2,1 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,1 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"4,7 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"5,1 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"5,4 µm"},{"name":"","range":"375 mm do 400 mm","cmc":"5,7 µm"},{"name":"","range":"400 mm do 425 mm","cmc":"6,1 µm"},{"name":"","range":"425 mm do 450 mm","cmc":"6,4 µm"},{"name":"","range":"450 mm do 475 mm","cmc":"6,8 µm"},{"name":"","range":"475 mm do 500 mm","cmc":"7,1 µm"}],"regulatory_area_de":"Länge","search_de":"Bügelmessschrauben Kalibrierung — Länge Am festen Standort (S) Länge Am festen Standort (S) PN-EN ISO 3611:2023","technique_de":"Am festen Standort (S)","techniques_de":["Am festen Standort (S)"],"test_object_de":"Bügelmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"2,1 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,1 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"4,7 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"5,1 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"5,4 µm"},{"name":"","range":"375 mm do 400 mm","cmc":"5,7 µm"},{"name":"","range":"400 mm do 425 mm","cmc":"6,1 µm"},{"name":"","range":"425 mm do 450 mm","cmc":"6,4 µm"},{"name":"","range":"450 mm do 475 mm","cmc":"6,8 µm"},{"name":"","range":"475 mm do 500 mm","cmc":"7,1 µm"}],"regulatory_area_zh":"长度","search_zh":"外径千分尺 校准 — 长度 在固定地点 (S) 长度 在固定地点 (S) PN-EN ISO 3611:2023","technique_zh":"在固定地点 (S)","techniques_zh":["在固定地点 (S)"],"test_object_zh":"外径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,1 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,1 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"4,7 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"5,1 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"5,4 µm"},{"name":"","range":"375 mm do 400 mm","cmc":"5,7 µm"},{"name":"","range":"400 mm do 425 mm","cmc":"6,1 µm"},{"name":"","range":"425 mm do 450 mm","cmc":"6,4 µm"},{"name":"","range":"450 mm do 475 mm","cmc":"6,8 µm"},{"name":"","range":"475 mm do 500 mm","cmc":"7,1 µm"}],"regulatory_area_cs":"Délka","search_cs":"Mikrometry pro vnější měření Kalibrace — Délka Ve stálé lokalitě (S) Délka Ve stálé lokalitě (S) PN-EN ISO 3611:2023","technique_cs":"Ve stálé lokalitě (S)","techniques_cs":["Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometry pro vnější měření"},{"_id":"e4a0126d65c08001867ef564","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Mikrometry wewnętrzne","test_object_en":"Internal micrometers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"5 mm do 100 mm","cmc":"2,3 µm"}],"parameters_en":[{"name":"","range":"5 mm to 100 mm","cmc":"2,3 µm"}],"technique":"Procedura wewnętrzna; przy użyciu pierścieni wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using setting rings; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu pierścieni wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using setting rings","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n5 mm do 100 mm CMC 2,3 µm\nProcedura wewnętrzna; przy użyciu pierścieni wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-10-LW-AK-01","norm_bases":["IW-10-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mikrometry wewnętrzne Wzorcowanie — Długość\n5 mm do 100 mm CMC 2,3 µm\nProcedura wewnętrzna; przy użyciu pierścieni wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-10-LW-AK-01 Mikrometry wewnetrzne Wzorcowanie — Dlugosc\n5 mm do 100 mm CMC 2,3 µm\nProcedura wewnetrzna; przy uzyciu pierscieni wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-10-LW-AK-01","search_en":"Internal micrometers Calibration — Length Internal procedure; using setting rings; At permanent location (S) Length Internal procedure using setting rings At permanent location (S) Internal procedure IW-10-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":50,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-10-LW-AK-01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"5 mm to 100 mm","cmc":"2,3 µm"}],"reference_de":"Internes Verfahren IW-10-LW-AK-01","regulatory_area_de":"Länge","search_de":"Innenmessschrauben Kalibrierung — Länge Internes Verfahren; mit Einstellringen; Am festen Standort (S) Länge Internes Verfahren mit Einstellringen Am festen Standort (S) Internes Verfahren IW-10-LW-AK-01","technique_de":"Internes Verfahren; mit Einstellringen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Einstellringen","Am festen Standort (S)"],"test_object_de":"Innenmessschrauben","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"5 mm to 100 mm","cmc":"2,3 µm"}],"reference_zh":"内部程序 IW-10-LW-AK-01","regulatory_area_zh":"长度","search_zh":"内径千分尺 校准 — 长度 内部程序；使用校对环规；在固定地点 (S) 长度 内部程序 使用校对环规 在固定地点 (S) 内部程序 IW-10-LW-AK-01","technique_zh":"内部程序；使用校对环规；在固定地点 (S)","techniques_zh":["内部程序","使用校对环规","在固定地点 (S)"],"test_object_zh":"内径千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"5 mm to 100 mm","cmc":"2,3 µm"}],"reference_cs":"Vnitřní postup IW-10-LW-AK-01","regulatory_area_cs":"Délka","search_cs":"Vnitřní mikrometry Kalibrace — Délka Vnitřní postup; pomocí nastavovacích kroužků; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí nastavovacích kroužků Ve stálé lokalitě (S) Vnitřní postup IW-10-LW-AK-01","technique_cs":"Vnitřní postup; pomocí nastavovacích kroužků; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí nastavovacích kroužků","Ve stálé lokalitě (S)"],"test_object_cs":"Vnitřní mikrometry"},{"_id":"00e2ca8110ae110bb1835995","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Głębokościomierze mikrometryczne","test_object_en":"Micrometer depth gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,1 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,1 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"4,7 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"5,1 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"5,4 µm"},{"name":"","range":"375 mm do 400 mm","cmc":"5,7 µm"},{"name":"","range":"400 mm do 425 mm","cmc":"6,1 µm"},{"name":"","range":"425 mm do 450 mm","cmc":"6,4 µm"},{"name":"","range":"450 mm do 475 mm","cmc":"6,8 µm"},{"name":"","range":"475 mm do 500 mm","cmc":"7,1 µm"}],"parameters_en":[{"name":"","range":"0 mm to 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm to 125 mm","cmc":"2,1 µm"},{"name":"","range":"125 mm to 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm to 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm to 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,1 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"4,7 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"5,1 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"5,4 µm"},{"name":"","range":"375 mm do 400 mm","cmc":"5,7 µm"},{"name":"","range":"400 mm do 425 mm","cmc":"6,1 µm"},{"name":"","range":"425 mm do 450 mm","cmc":"6,4 µm"},{"name":"","range":"450 mm do 475 mm","cmc":"6,8 µm"},{"name":"","range":"475 mm do 500 mm","cmc":"7,1 µm"}],"technique":"Procedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,0 µm\n25 mm do 50 mm CMC 1,2 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,1 µm\n125 mm do 150 mm CMC 2,4 µm\n150 mm do 175 mm CMC 2,7 µm\n175 mm do 200 mm CMC 3,0 µm\n200 mm do 225 mm CMC 3,4 µm\n225 mm do 250 mm CMC 3,7 µm\n250 mm do 275 mm CMC 4,1 µm\n275 mm do 300 mm CMC 4,4 µm\n300 mm do 325 mm CMC 4,7 µm\n325 mm do 350 mm CMC 5,1 µm\n350 mm do 375 mm CMC 5,4 µm\n375 mm do 400 mm CMC 5,7 µm\n400 mm do 425 mm CMC 6,1 µm\n425 mm do 450 mm CMC 6,4 µm\n450 mm do 475 mm CMC 6,8 µm\n475 mm do 500 mm CMC 7,1 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-11-LW-AK-01","norm_bases":["IW-11-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze mikrometryczne Wzorcowanie — Długość\nZakres:\n0 mm do 25 mm CMC 1,0 µm\n25 mm do 50 mm CMC 1,2 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,1 µm\n125 mm do 150 mm CMC 2,4 µm\n150 mm do 175 mm CMC 2,7 µm\n175 mm do 200 mm CMC 3,0 µm\n200 mm do 225 mm CMC 3,4 µm\n225 mm do 250 mm CMC 3,7 µm\n250 mm do 275 mm CMC 4,1 µm\n275 mm do 300 mm CMC 4,4 µm\n300 mm do 325 mm CMC 4,7 µm\n325 mm do 350 mm CMC 5,1 µm\n350 mm do 375 mm CMC 5,4 µm\n375 mm do 400 mm CMC 5,7 µm\n400 mm do 425 mm CMC 6,1 µm\n425 mm do 450 mm CMC 6,4 µm\n450 mm do 475 mm CMC 6,8 µm\n475 mm do 500 mm CMC 7,1 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-11-LW-AK-01 Glebokosciomierze mikrometryczne Wzorcowanie — Dlugosc\nZakres:\n0 mm do 25 mm CMC 1,0 µm\n25 mm do 50 mm CMC 1,2 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 125 mm CMC 2,1 µm\n125 mm do 150 mm CMC 2,4 µm\n150 mm do 175 mm CMC 2,7 µm\n175 mm do 200 mm CMC 3,0 µm\n200 mm do 225 mm CMC 3,4 µm\n225 mm do 250 mm CMC 3,7 µm\n250 mm do 275 mm CMC 4,1 µm\n275 mm do 300 mm CMC 4,4 µm\n300 mm do 325 mm CMC 4,7 µm\n325 mm do 350 mm CMC 5,1 µm\n350 mm do 375 mm CMC 5,4 µm\n375 mm do 400 mm CMC 5,7 µm\n400 mm do 425 mm CMC 6,1 µm\n425 mm do 450 mm CMC 6,4 µm\n450 mm do 475 mm CMC 6,8 µm\n475 mm do 500 mm CMC 7,1 µm\nProcedura wewnetrzna; przy uzyciu plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-11-LW-AK-01","search_en":"Micrometer depth gauges Calibration — Length Internal procedure; using gauge blocks; At permanent location (S) Length Internal procedure using gauge blocks At permanent location (S) Internal procedure IW-11-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":51,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-11-LW-AK-01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm bis 125 mm","cmc":"2,1 µm"},{"name":"","range":"125 mm bis 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm bis 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm bis 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,1 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"4,7 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"5,1 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"5,4 µm"},{"name":"","range":"375 mm do 400 mm","cmc":"5,7 µm"},{"name":"","range":"400 mm do 425 mm","cmc":"6,1 µm"},{"name":"","range":"425 mm do 450 mm","cmc":"6,4 µm"},{"name":"","range":"450 mm do 475 mm","cmc":"6,8 µm"},{"name":"","range":"475 mm do 500 mm","cmc":"7,1 µm"}],"reference_de":"Internes Verfahren IW-11-LW-AK-01","regulatory_area_de":"Länge","search_de":"Mikrometer-Tiefenmessgeräte Kalibrierung — Länge Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW-11-LW-AK-01","technique_de":"Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Mikrometer-Tiefenmessgeräte","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm 至 125 mm","cmc":"2,1 µm"},{"name":"","range":"125 mm 至 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm 至 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm 至 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,1 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"4,7 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"5,1 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"5,4 µm"},{"name":"","range":"375 mm do 400 mm","cmc":"5,7 µm"},{"name":"","range":"400 mm do 425 mm","cmc":"6,1 µm"},{"name":"","range":"425 mm do 450 mm","cmc":"6,4 µm"},{"name":"","range":"450 mm do 475 mm","cmc":"6,8 µm"},{"name":"","range":"475 mm do 500 mm","cmc":"7,1 µm"}],"reference_zh":"内部程序 IW-11-LW-AK-01","regulatory_area_zh":"长度","search_zh":"深度千分尺 校准 — 长度 内部程序；使用量块；在固定地点 (S) 长度 内部程序 使用量块 在固定地点 (S) 内部程序 IW-11-LW-AK-01","technique_zh":"内部程序；使用量块；在固定地点 (S)","techniques_zh":["内部程序","使用量块","在固定地点 (S)"],"test_object_zh":"深度千分尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 25 mm","cmc":"1,0 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,2 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 125 mm","cmc":"2,1 µm"},{"name":"","range":"125 mm do 150 mm","cmc":"2,4 µm"},{"name":"","range":"150 mm do 175 mm","cmc":"2,7 µm"},{"name":"","range":"175 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 225 mm","cmc":"3,4 µm"},{"name":"","range":"225 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 275 mm","cmc":"4,1 µm"},{"name":"","range":"275 mm do 300 mm","cmc":"4,4 µm"},{"name":"","range":"300 mm do 325 mm","cmc":"4,7 µm"},{"name":"","range":"325 mm do 350 mm","cmc":"5,1 µm"},{"name":"","range":"350 mm do 375 mm","cmc":"5,4 µm"},{"name":"","range":"375 mm do 400 mm","cmc":"5,7 µm"},{"name":"","range":"400 mm do 425 mm","cmc":"6,1 µm"},{"name":"","range":"425 mm do 450 mm","cmc":"6,4 µm"},{"name":"","range":"450 mm do 475 mm","cmc":"6,8 µm"},{"name":"","range":"475 mm do 500 mm","cmc":"7,1 µm"}],"reference_cs":"Vnitřní postup IW-11-LW-AK-01","regulatory_area_cs":"Délka","search_cs":"Mikrometrické hloubkoměry Kalibrace — Délka Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW-11-LW-AK-01","technique_cs":"Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Mikrometrické hloubkoměry"},{"_id":"73fbda6c034d9476e0eb5495","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Głębokościomierze czujnikowe z odczytem analogowym o wartości działki elementarnej:","test_object_en":"Dial depth gauges with analogue reading, scale interval:","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- 0,001 mm","range":"0 mm do 5 mm","cmc":"0,6 µm"},{"name":"- 0,002 mm","range":"0 mm do 5 mm","cmc":"0,6 µm"},{"name":"- 0,005 mm","range":"0 mm do 10 mm","cmc":"0,7 µm"},{"name":"- 0,01 mm","range":"0 mm do 10 mm","cmc":"1,2 µm"},{"name":"- 0,01 mm","range":"10 mm do 100 mm","cmc":"2,1 µm"},{"name":"- 0,1 mm","range":"0 mm do 100 mm","cmc":"8,3 µm"}],"parameters_en":[{"name":"- 0,001 mm","range":"0 mm to 5 mm","cmc":"0,6 µm"},{"name":"- 0,002 mm","range":"0 mm to 5 mm","cmc":"0,6 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"- 0,01 mm","range":"0 mm to 10 mm","cmc":"1,2 µm"},{"name":"- 0,01 mm","range":"10 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"8,3 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR oraz współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR and the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR oraz współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR and the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- 0,001 mm 0 mm do 5 mm CMC 0,6 µm\n- 0,002 mm 0 mm do 5 mm CMC 0,6 µm\n- 0,005 mm 0 mm do 10 mm CMC 0,7 µm\n- 0,01 mm 0 mm do 10 mm CMC 1,2 µm\n- 0,01 mm 10 mm do 100 mm CMC 2,1 µm\n- 0,1 mm 0 mm do 100 mm CMC 8,3 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR oraz współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-6-LW-AK 01","norm_bases":["IW-6-LW-AK 01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze czujnikowe z odczytem analogowym o wartości działki elementarnej: Wzorcowanie — Długość\nZakres:\n- 0,001 mm 0 mm do 5 mm CMC 0,6 µm\n- 0,002 mm 0 mm do 5 mm CMC 0,6 µm\n- 0,005 mm 0 mm do 10 mm CMC 0,7 µm\n- 0,01 mm 0 mm do 10 mm CMC 1,2 µm\n- 0,01 mm 10 mm do 100 mm CMC 2,1 µm\n- 0,1 mm 0 mm do 100 mm CMC 8,3 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR oraz współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-6-LW-AK 01 Glebokosciomierze czujnikowe z odczytem analogowym o wartosci dzialki elementarnej: Wzorcowanie — Dlugosc\nZakres:\n- 0,001 mm 0 mm do 5 mm CMC 0,6 µm\n- 0,002 mm 0 mm do 5 mm CMC 0,6 µm\n- 0,005 mm 0 mm do 10 mm CMC 0,7 µm\n- 0,01 mm 0 mm do 10 mm CMC 1,2 µm\n- 0,01 mm 10 mm do 100 mm CMC 2,1 µm\n- 0,1 mm 0 mm do 100 mm CMC 8,3 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR oraz wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-6-LW-AK 01","search_en":"Dial depth gauges with analogue reading, scale interval: Calibration — Length Internal procedure; using OPTIMAR and the O-Inspect coordinate measuring machine; At permanent location (S) Length Internal procedure using OPTIMAR and the O-Inspect coordinate measuring machine At permanent location (S) - 0,001 mm - 0,002 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,1 mm Internal procedure IW-6-LW-AK 01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":52,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-6-LW-AK 01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- 0,001 mm","range":"0 mm to 5 mm","cmc":"0,6 µm"},{"name":"- 0,002 mm","range":"0 mm to 5 mm","cmc":"0,6 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"- 0,01 mm","range":"0 mm to 10 mm","cmc":"1,2 µm"},{"name":"- 0,01 mm","range":"10 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"8,3 µm"}],"reference_de":"Internes Verfahren IW-6-LW-AK 01","regulatory_area_de":"Länge","search_de":"Tiefenmessuhren mit analoger Anzeige mit einem Skalenteilungswert von: Kalibrierung — Länge Internes Verfahren; mit OPTIMAR und dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR und dem Koordinatenmessgerät O-Inspect Am festen Standort (S) - 0,001 mm - 0,002 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,1 mm Internes Verfahren IW-6-LW-AK 01","technique_de":"Internes Verfahren; mit OPTIMAR und dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR und dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Tiefenmessuhren mit analoger Anzeige mit einem Skalenteilungswert von:","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 0,001 mm","range":"0 mm to 5 mm","cmc":"0,6 µm"},{"name":"- 0,002 mm","range":"0 mm to 5 mm","cmc":"0,6 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"- 0,01 mm","range":"0 mm to 10 mm","cmc":"1,2 µm"},{"name":"- 0,01 mm","range":"10 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"8,3 µm"}],"reference_zh":"内部程序 IW-6-LW-AK 01","regulatory_area_zh":"长度","search_zh":"模拟读数指示式深度尺，分度值： 校准 — 长度 内部程序；使用OPTIMAR和O-Inspect坐标测量机；在固定地点 (S) 长度 内部程序 使用OPTIMAR和O-Inspect坐标测量机 在固定地点 (S) - 0,001 mm - 0,002 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,1 mm 内部程序 IW-6-LW-AK 01","technique_zh":"内部程序；使用OPTIMAR和O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR和O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"模拟读数指示式深度尺，分度值：","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- 0,001 mm","range":"0 mm to 5 mm","cmc":"0,6 µm"},{"name":"- 0,002 mm","range":"0 mm to 5 mm","cmc":"0,6 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"0,7 µm"},{"name":"- 0,01 mm","range":"0 mm to 10 mm","cmc":"1,2 µm"},{"name":"- 0,01 mm","range":"10 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"8,3 µm"}],"reference_cs":"Vnitřní postup IW-6-LW-AK 01","regulatory_area_cs":"Délka","search_cs":"Hloubkoměry s úchylkoměrem s analogovým odečtem s hodnotou dílku: Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR a souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR a souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) - 0,001 mm - 0,002 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,1 mm Vnitřní postup IW-6-LW-AK 01","technique_cs":"Vnitřní postup; pomocí OPTIMAR a souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR a souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Hloubkoměry s úchylkoměrem s analogovým odečtem s hodnotou dílku:"},{"_id":"ddb619d946641753d320d739","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Głębokościomierze czujnikowe z odczytem cyfrowym o rozdzielczości:","test_object_en":"Dial depth gauges with digital reading, resolution:","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- 0,0002 mm","range":"0 mm do 10 mm","cmc":"0,5 µm"},{"name":"- 0,0002 mm","range":"10 mm do 100 mm","cmc":"0,7 µm"},{"name":"- 0,0005 mm","range":"0 mm do 10 mm","cmc":"0,5 µm"},{"name":"- 0,0005 mm","range":"10 mm do 100 mm","cmc":"0,7 µm"},{"name":"- 0,001 mm","range":"0 mm do 10 mm","cmc":"0,6 µm"},{"name":"- 0,001 mm","range":"10 mm do 100 mm","cmc":"1,5 µm"},{"name":"- 0,002 mm","range":"0 mm do 10 mm","cmc":"1,3 µm"},{"name":"- 0,002 mm","range":"10 mm do 100 mm","cmc":"1,4 µm"},{"name":"- 0,005 mm","range":"0 mm do 10 mm","cmc":"1,3 µm"},{"name":"- 0,005 mm","range":"10 mm do 100 mm","cmc":"1,4 µm"},{"name":"- 0,01 mm","range":"0 mm do 10 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"10 mm do 100 mm","cmc":"2,1 µm"},{"name":"- 0,02 mm","range":"0 mm do 100 mm","cmc":"5,9 µm"},{"name":"- 0,05 mm","range":"0 mm do 100 mm","cmc":"14,5 µm"},{"name":"- 0,1 mm","range":"0 mm do 100 mm","cmc":"28,9 µm"},{"name":"- 0,2 mm","range":"0 mm do 100 mm","cmc":"57,8 µm"}],"parameters_en":[{"name":"- 0,0002 mm","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"- 0,0002 mm","range":"10 mm to 100 mm","cmc":"0,7 µm"},{"name":"- 0,0005 mm","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"- 0,0005 mm","range":"10 mm to 100 mm","cmc":"0,7 µm"},{"name":"- 0,001 mm","range":"0 mm to 10 mm","cmc":"0,6 µm"},{"name":"- 0,001 mm","range":"10 mm to 100 mm","cmc":"1,5 µm"},{"name":"- 0,002 mm","range":"0 mm to 10 mm","cmc":"1,3 µm"},{"name":"- 0,002 mm","range":"10 mm to 100 mm","cmc":"1,4 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"1,3 µm"},{"name":"- 0,005 mm","range":"10 mm to 100 mm","cmc":"1,4 µm"},{"name":"- 0,01 mm","range":"0 mm to 10 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"10 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,02 mm","range":"0 mm to 100 mm","cmc":"5,9 µm"},{"name":"- 0,05 mm","range":"0 mm to 100 mm","cmc":"14,5 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"28,9 µm"},{"name":"- 0,2 mm","range":"0 mm to 100 mm","cmc":"57,8 µm"}],"technique":"Procedura wewnętrzna; przy użyciu OPTIMAR oraz współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using OPTIMAR and the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu OPTIMAR oraz współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using OPTIMAR and the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- 0,0002 mm 0 mm do 10 mm CMC 0,5 µm\n- 0,0002 mm 10 mm do 100 mm CMC 0,7 µm\n- 0,0005 mm 0 mm do 10 mm CMC 0,5 µm\n- 0,0005 mm 10 mm do 100 mm CMC 0,7 µm\n- 0,001 mm 0 mm do 10 mm CMC 0,6 µm\n- 0,001 mm 10 mm do 100 mm CMC 1,5 µm\n- 0,002 mm 0 mm do 10 mm CMC 1,3 µm\n- 0,002 mm 10 mm do 100 mm CMC 1,4 µm\n- 0,005 mm 0 mm do 10 mm CMC 1,3 µm\n- 0,005 mm 10 mm do 100 mm CMC 1,4 µm\n- 0,01 mm 0 mm do 10 mm CMC 1,8 µm\n- 0,01 mm 10 mm do 100 mm CMC 2,1 µm\n- 0,02 mm 0 mm do 100 mm CMC 5,9 µm\n- 0,05 mm 0 mm do 100 mm CMC 14,5 µm\n- 0,1 mm 0 mm do 100 mm CMC 28,9 µm\n- 0,2 mm 0 mm do 100 mm CMC 57,8 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR oraz współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-6-LW-AK 01","norm_bases":["IW-6-LW-AK 01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Głębokościomierze czujnikowe z odczytem cyfrowym o rozdzielczości: Wzorcowanie — Długość\nZakres:\n- 0,0002 mm 0 mm do 10 mm CMC 0,5 µm\n- 0,0002 mm 10 mm do 100 mm CMC 0,7 µm\n- 0,0005 mm 0 mm do 10 mm CMC 0,5 µm\n- 0,0005 mm 10 mm do 100 mm CMC 0,7 µm\n- 0,001 mm 0 mm do 10 mm CMC 0,6 µm\n- 0,001 mm 10 mm do 100 mm CMC 1,5 µm\n- 0,002 mm 0 mm do 10 mm CMC 1,3 µm\n- 0,002 mm 10 mm do 100 mm CMC 1,4 µm\n- 0,005 mm 0 mm do 10 mm CMC 1,3 µm\n- 0,005 mm 10 mm do 100 mm CMC 1,4 µm\n- 0,01 mm 0 mm do 10 mm CMC 1,8 µm\n- 0,01 mm 10 mm do 100 mm CMC 2,1 µm\n- 0,02 mm 0 mm do 100 mm CMC 5,9 µm\n- 0,05 mm 0 mm do 100 mm CMC 14,5 µm\n- 0,1 mm 0 mm do 100 mm CMC 28,9 µm\n- 0,2 mm 0 mm do 100 mm CMC 57,8 µm\nProcedura wewnętrzna; przy użyciu OPTIMAR oraz współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-6-LW-AK 01 Glebokosciomierze czujnikowe z odczytem cyfrowym o rozdzielczosci: Wzorcowanie — Dlugosc\nZakres:\n- 0,0002 mm 0 mm do 10 mm CMC 0,5 µm\n- 0,0002 mm 10 mm do 100 mm CMC 0,7 µm\n- 0,0005 mm 0 mm do 10 mm CMC 0,5 µm\n- 0,0005 mm 10 mm do 100 mm CMC 0,7 µm\n- 0,001 mm 0 mm do 10 mm CMC 0,6 µm\n- 0,001 mm 10 mm do 100 mm CMC 1,5 µm\n- 0,002 mm 0 mm do 10 mm CMC 1,3 µm\n- 0,002 mm 10 mm do 100 mm CMC 1,4 µm\n- 0,005 mm 0 mm do 10 mm CMC 1,3 µm\n- 0,005 mm 10 mm do 100 mm CMC 1,4 µm\n- 0,01 mm 0 mm do 10 mm CMC 1,8 µm\n- 0,01 mm 10 mm do 100 mm CMC 2,1 µm\n- 0,02 mm 0 mm do 100 mm CMC 5,9 µm\n- 0,05 mm 0 mm do 100 mm CMC 14,5 µm\n- 0,1 mm 0 mm do 100 mm CMC 28,9 µm\n- 0,2 mm 0 mm do 100 mm CMC 57,8 µm\nProcedura wewnetrzna; przy uzyciu OPTIMAR oraz wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-6-LW-AK 01","search_en":"Dial depth gauges with digital reading, resolution: Calibration — Length Internal procedure; using OPTIMAR and the O-Inspect coordinate measuring machine; At permanent location (S) Length Internal procedure using OPTIMAR and the O-Inspect coordinate measuring machine At permanent location (S) - 0,0002 mm - 0,0002 mm - 0,0005 mm - 0,0005 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,02 mm - 0,05 mm - 0,1 mm - 0,2 mm Internal procedure IW-6-LW-AK 01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":53,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-6-LW-AK 01","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- 0,0002 mm","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"- 0,0002 mm","range":"10 mm to 100 mm","cmc":"0,7 µm"},{"name":"- 0,0005 mm","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"- 0,0005 mm","range":"10 mm to 100 mm","cmc":"0,7 µm"},{"name":"- 0,001 mm","range":"0 mm to 10 mm","cmc":"0,6 µm"},{"name":"- 0,001 mm","range":"10 mm to 100 mm","cmc":"1,5 µm"},{"name":"- 0,002 mm","range":"0 mm to 10 mm","cmc":"1,3 µm"},{"name":"- 0,002 mm","range":"10 mm to 100 mm","cmc":"1,4 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"1,3 µm"},{"name":"- 0,005 mm","range":"10 mm to 100 mm","cmc":"1,4 µm"},{"name":"- 0,01 mm","range":"0 mm to 10 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"10 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,02 mm","range":"0 mm to 100 mm","cmc":"5,9 µm"},{"name":"- 0,05 mm","range":"0 mm to 100 mm","cmc":"14,5 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"28,9 µm"},{"name":"- 0,2 mm","range":"0 mm to 100 mm","cmc":"57,8 µm"}],"reference_de":"Internes Verfahren IW-6-LW-AK 01","regulatory_area_de":"Länge","search_de":"Tiefenmessuhren mit digitaler Anzeige mit einer Auflösung von: Kalibrierung — Länge Internes Verfahren; mit OPTIMAR und dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge Internes Verfahren mit OPTIMAR und dem Koordinatenmessgerät O-Inspect Am festen Standort (S) - 0,0002 mm - 0,0002 mm - 0,0005 mm - 0,0005 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,02 mm - 0,05 mm - 0,1 mm - 0,2 mm Internes Verfahren IW-6-LW-AK 01","technique_de":"Internes Verfahren; mit OPTIMAR und dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit OPTIMAR und dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Tiefenmessuhren mit digitaler Anzeige mit einer Auflösung von:","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 0,0002 mm","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"- 0,0002 mm","range":"10 mm to 100 mm","cmc":"0,7 µm"},{"name":"- 0,0005 mm","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"- 0,0005 mm","range":"10 mm to 100 mm","cmc":"0,7 µm"},{"name":"- 0,001 mm","range":"0 mm to 10 mm","cmc":"0,6 µm"},{"name":"- 0,001 mm","range":"10 mm to 100 mm","cmc":"1,5 µm"},{"name":"- 0,002 mm","range":"0 mm to 10 mm","cmc":"1,3 µm"},{"name":"- 0,002 mm","range":"10 mm to 100 mm","cmc":"1,4 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"1,3 µm"},{"name":"- 0,005 mm","range":"10 mm to 100 mm","cmc":"1,4 µm"},{"name":"- 0,01 mm","range":"0 mm to 10 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"10 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,02 mm","range":"0 mm to 100 mm","cmc":"5,9 µm"},{"name":"- 0,05 mm","range":"0 mm to 100 mm","cmc":"14,5 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"28,9 µm"},{"name":"- 0,2 mm","range":"0 mm to 100 mm","cmc":"57,8 µm"}],"reference_zh":"内部程序 IW-6-LW-AK 01","regulatory_area_zh":"长度","search_zh":"数显读数指示式深度尺，分辨力： 校准 — 长度 内部程序；使用OPTIMAR和O-Inspect坐标测量机；在固定地点 (S) 长度 内部程序 使用OPTIMAR和O-Inspect坐标测量机 在固定地点 (S) - 0,0002 mm - 0,0002 mm - 0,0005 mm - 0,0005 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,02 mm - 0,05 mm - 0,1 mm - 0,2 mm 内部程序 IW-6-LW-AK 01","technique_zh":"内部程序；使用OPTIMAR和O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用OPTIMAR和O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"数显读数指示式深度尺，分辨力：","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- 0,0002 mm","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"- 0,0002 mm","range":"10 mm to 100 mm","cmc":"0,7 µm"},{"name":"- 0,0005 mm","range":"0 mm to 10 mm","cmc":"0,5 µm"},{"name":"- 0,0005 mm","range":"10 mm to 100 mm","cmc":"0,7 µm"},{"name":"- 0,001 mm","range":"0 mm to 10 mm","cmc":"0,6 µm"},{"name":"- 0,001 mm","range":"10 mm to 100 mm","cmc":"1,5 µm"},{"name":"- 0,002 mm","range":"0 mm to 10 mm","cmc":"1,3 µm"},{"name":"- 0,002 mm","range":"10 mm to 100 mm","cmc":"1,4 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"1,3 µm"},{"name":"- 0,005 mm","range":"10 mm to 100 mm","cmc":"1,4 µm"},{"name":"- 0,01 mm","range":"0 mm to 10 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"10 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,02 mm","range":"0 mm to 100 mm","cmc":"5,9 µm"},{"name":"- 0,05 mm","range":"0 mm to 100 mm","cmc":"14,5 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"28,9 µm"},{"name":"- 0,2 mm","range":"0 mm to 100 mm","cmc":"57,8 µm"}],"reference_cs":"Vnitřní postup IW-6-LW-AK 01","regulatory_area_cs":"Délka","search_cs":"Hloubkoměry s úchylkoměrem s digitálním odečtem s rozlišením: Kalibrace — Délka Vnitřní postup; pomocí OPTIMAR a souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí OPTIMAR a souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) - 0,0002 mm - 0,0002 mm - 0,0005 mm - 0,0005 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,02 mm - 0,05 mm - 0,1 mm - 0,2 mm Vnitřní postup IW-6-LW-AK 01","technique_cs":"Vnitřní postup; pomocí OPTIMAR a souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí OPTIMAR a souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Hloubkoměry s úchylkoměrem s digitálním odečtem s rozlišením:"},{"_id":"7a7b110969a8863cf46200b0","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Grubościomierze czujnikowe z czujnikiem analogowym o wartości o działki elementarnej:","test_object_en":"Dial thickness gauges with an analogue indicator, scale interval:","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- 0,001 mm","range":"0 mm do 5 mm","cmc":"1,0 µm"},{"name":"- 0,002 mm","range":"0 mm do 10 mm","cmc":"1,0 µm"},{"name":"- 0,005 mm","range":"0 mm do 10 mm","cmc":"1,1 µm"},{"name":"- 0,005 mm","range":"0 mm do 50 mm","cmc":"1,3 µm"},{"name":"- 0,005 mm","range":"0 mm do 75 mm","cmc":"1,5 µm"},{"name":"- 0,005 mm","range":"0 mm do 100 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"0 mm do 25 mm","cmc":"1,5 µm"},{"name":"- 0,01 mm","range":"0 mm do 50 mm","cmc":"1,6 µm"},{"name":"- 0,01 mm","range":"0 mm do 75 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"0 mm do 100 mm","cmc":"2,0 µm"},{"name":"- 0,1 mm","range":"0 mm do 60 mm","cmc":"5,9 µm"},{"name":"- 0,1 mm","range":"0 mm do 100 mm","cmc":"6,0 µm"}],"parameters_en":[{"name":"- 0,001 mm","range":"0 mm to 5 mm","cmc":"1,0 µm"},{"name":"- 0,002 mm","range":"0 mm to 10 mm","cmc":"1,0 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"1,1 µm"},{"name":"- 0,005 mm","range":"0 mm to 50 mm","cmc":"1,3 µm"},{"name":"- 0,005 mm","range":"0 mm to 75 mm","cmc":"1,5 µm"},{"name":"- 0,005 mm","range":"0 mm to 100 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"0 mm to 25 mm","cmc":"1,5 µm"},{"name":"- 0,01 mm","range":"0 mm to 50 mm","cmc":"1,6 µm"},{"name":"- 0,01 mm","range":"0 mm to 75 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"0 mm to 100 mm","cmc":"2,0 µm"},{"name":"- 0,1 mm","range":"0 mm to 60 mm","cmc":"5,9 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"6,0 µm"}],"technique":"Procedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- 0,001 mm 0 mm do 5 mm CMC 1,0 µm\n- 0,002 mm 0 mm do 10 mm CMC 1,0 µm\n- 0,005 mm 0 mm do 10 mm CMC 1,1 µm\n- 0,005 mm 0 mm do 50 mm CMC 1,3 µm\n- 0,005 mm 0 mm do 75 mm CMC 1,5 µm\n- 0,005 mm 0 mm do 100 mm CMC 1,8 µm\n- 0,01 mm 0 mm do 25 mm CMC 1,5 µm\n- 0,01 mm 0 mm do 50 mm CMC 1,6 µm\n- 0,01 mm 0 mm do 75 mm CMC 1,8 µm\n- 0,01 mm 0 mm do 100 mm CMC 2,0 µm\n- 0,1 mm 0 mm do 60 mm CMC 5,9 µm\n- 0,1 mm 0 mm do 100 mm CMC 6,0 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-10-LW-AK-02","norm_bases":["IW-10-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Grubościomierze czujnikowe z czujnikiem analogowym o wartości o działki elementarnej: Wzorcowanie — Długość\nZakres:\n- 0,001 mm 0 mm do 5 mm CMC 1,0 µm\n- 0,002 mm 0 mm do 10 mm CMC 1,0 µm\n- 0,005 mm 0 mm do 10 mm CMC 1,1 µm\n- 0,005 mm 0 mm do 50 mm CMC 1,3 µm\n- 0,005 mm 0 mm do 75 mm CMC 1,5 µm\n- 0,005 mm 0 mm do 100 mm CMC 1,8 µm\n- 0,01 mm 0 mm do 25 mm CMC 1,5 µm\n- 0,01 mm 0 mm do 50 mm CMC 1,6 µm\n- 0,01 mm 0 mm do 75 mm CMC 1,8 µm\n- 0,01 mm 0 mm do 100 mm CMC 2,0 µm\n- 0,1 mm 0 mm do 60 mm CMC 5,9 µm\n- 0,1 mm 0 mm do 100 mm CMC 6,0 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-10-LW-AK-02 Grubosciomierze czujnikowe z czujnikiem analogowym o wartosci o dzialki elementarnej: Wzorcowanie — Dlugosc\nZakres:\n- 0,001 mm 0 mm do 5 mm CMC 1,0 µm\n- 0,002 mm 0 mm do 10 mm CMC 1,0 µm\n- 0,005 mm 0 mm do 10 mm CMC 1,1 µm\n- 0,005 mm 0 mm do 50 mm CMC 1,3 µm\n- 0,005 mm 0 mm do 75 mm CMC 1,5 µm\n- 0,005 mm 0 mm do 100 mm CMC 1,8 µm\n- 0,01 mm 0 mm do 25 mm CMC 1,5 µm\n- 0,01 mm 0 mm do 50 mm CMC 1,6 µm\n- 0,01 mm 0 mm do 75 mm CMC 1,8 µm\n- 0,01 mm 0 mm do 100 mm CMC 2,0 µm\n- 0,1 mm 0 mm do 60 mm CMC 5,9 µm\n- 0,1 mm 0 mm do 100 mm CMC 6,0 µm\nProcedura wewnetrzna; przy uzyciu plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-10-LW-AK-02","search_en":"Dial thickness gauges with an analogue indicator, scale interval: Calibration — Length Internal procedure; using gauge blocks; At permanent location (S) Length Internal procedure using gauge blocks At permanent location (S) - 0,001 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,1 mm - 0,1 mm Internal procedure IW-10-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":54,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-10-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- 0,001 mm","range":"0 mm to 5 mm","cmc":"1,0 µm"},{"name":"- 0,002 mm","range":"0 mm to 10 mm","cmc":"1,0 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"1,1 µm"},{"name":"- 0,005 mm","range":"0 mm bis 50 mm","cmc":"1,3 µm"},{"name":"- 0,005 mm","range":"0 mm to 75 mm","cmc":"1,5 µm"},{"name":"- 0,005 mm","range":"0 mm to 100 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"0 mm bis 25 mm","cmc":"1,5 µm"},{"name":"- 0,01 mm","range":"0 mm bis 50 mm","cmc":"1,6 µm"},{"name":"- 0,01 mm","range":"0 mm to 75 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"0 mm to 100 mm","cmc":"2,0 µm"},{"name":"- 0,1 mm","range":"0 mm to 60 mm","cmc":"5,9 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"6,0 µm"}],"reference_de":"Internes Verfahren IW-10-LW-AK-02","regulatory_area_de":"Länge","search_de":"Dickenmessgeräte mit analoger Messuhr, Skalenteilungswert: Kalibrierung — Länge Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren mit Parallelendmaßen Am festen Standort (S) - 0,001 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,1 mm - 0,1 mm Internes Verfahren IW-10-LW-AK-02","technique_de":"Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Dickenmessgeräte mit analoger Messuhr, Skalenteilungswert:","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 0,001 mm","range":"0 mm to 5 mm","cmc":"1,0 µm"},{"name":"- 0,002 mm","range":"0 mm to 10 mm","cmc":"1,0 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"1,1 µm"},{"name":"- 0,005 mm","range":"0 mm 至 50 mm","cmc":"1,3 µm"},{"name":"- 0,005 mm","range":"0 mm to 75 mm","cmc":"1,5 µm"},{"name":"- 0,005 mm","range":"0 mm to 100 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"0 mm 至 25 mm","cmc":"1,5 µm"},{"name":"- 0,01 mm","range":"0 mm 至 50 mm","cmc":"1,6 µm"},{"name":"- 0,01 mm","range":"0 mm to 75 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"0 mm to 100 mm","cmc":"2,0 µm"},{"name":"- 0,1 mm","range":"0 mm to 60 mm","cmc":"5,9 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"6,0 µm"}],"reference_zh":"内部程序 IW-10-LW-AK-02","regulatory_area_zh":"长度","search_zh":"带模拟指示表的指示式测厚仪，分度值： 校准 — 长度 内部程序；使用量块；在固定地点 (S) 长度 内部程序 使用量块 在固定地点 (S) - 0,001 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,1 mm - 0,1 mm 内部程序 IW-10-LW-AK-02","technique_zh":"内部程序；使用量块；在固定地点 (S)","techniques_zh":["内部程序","使用量块","在固定地点 (S)"],"test_object_zh":"带模拟指示表的指示式测厚仪，分度值：","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- 0,001 mm","range":"0 mm to 5 mm","cmc":"1,0 µm"},{"name":"- 0,002 mm","range":"0 mm to 10 mm","cmc":"1,0 µm"},{"name":"- 0,005 mm","range":"0 mm to 10 mm","cmc":"1,1 µm"},{"name":"- 0,005 mm","range":"0 mm do 50 mm","cmc":"1,3 µm"},{"name":"- 0,005 mm","range":"0 mm to 75 mm","cmc":"1,5 µm"},{"name":"- 0,005 mm","range":"0 mm to 100 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"0 mm do 25 mm","cmc":"1,5 µm"},{"name":"- 0,01 mm","range":"0 mm do 50 mm","cmc":"1,6 µm"},{"name":"- 0,01 mm","range":"0 mm to 75 mm","cmc":"1,8 µm"},{"name":"- 0,01 mm","range":"0 mm to 100 mm","cmc":"2,0 µm"},{"name":"- 0,1 mm","range":"0 mm to 60 mm","cmc":"5,9 µm"},{"name":"- 0,1 mm","range":"0 mm to 100 mm","cmc":"6,0 µm"}],"reference_cs":"Vnitřní postup IW-10-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Tloušťkoměry s analogovým úchylkoměrem s hodnotou dílku: Kalibrace — Délka Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí koncových měrek Ve stálé lokalitě (S) - 0,001 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,1 mm - 0,1 mm Vnitřní postup IW-10-LW-AK-02","technique_cs":"Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Tloušťkoměry s analogovým úchylkoměrem s hodnotou dílku:"},{"_id":"526c2973055212f765e29812","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Grubościomierze czujnikowe z czujnikiem cyfrowym o rozdzielczości:","test_object_en":"Dial thickness gauges with a digital indicator, resolution:","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- 0,001 mm","range":"0 mm do 25 mm","cmc":"1,2 µm"},{"name":"- 0,001 mm","range":"0 mm do 50 mm","cmc":"1,4 µm"},{"name":"- 0,001 mm","range":"0 mm do 75 mm","cmc":"1,6 µm"},{"name":"- 0,001 mm","range":"0 mm do 100 mm","cmc":"1,9 µm"},{"name":"- 0,002 mm","range":"0 mm do 25 mm","cmc":"1,6 µm"},{"name":"- 0,002 mm","range":"0 mm do 50 mm","cmc":"1,7 µm"},{"name":"- 0,002 mm","range":"0 mm do 75 mm","cmc":"1,9 µm"},{"name":"- 0,002 mm","range":"0 mm do 100 mm","cmc":"2,1 µm"},{"name":"- 0,005 mm","range":"0 mm do 50 mm","cmc":"3,2 µm"},{"name":"- 0,005 mm","range":"0 mm do 75 mm","cmc":"3,3 µm"},{"name":"- 0,005 mm","range":"0 mm do 100 mm","cmc":"3,4 µm"},{"name":"- 0,01 mm","range":"0 mm do 50 mm","cmc":"5,9 µm"},{"name":"- 0,01 mm","range":"0 mm do 100 mm","cmc":"6,0 µm"}],"parameters_en":[{"name":"- 0,001 mm","range":"0 mm to 25 mm","cmc":"1,2 µm"},{"name":"- 0,001 mm","range":"0 mm to 50 mm","cmc":"1,4 µm"},{"name":"- 0,001 mm","range":"0 mm to 75 mm","cmc":"1,6 µm"},{"name":"- 0,001 mm","range":"0 mm to 100 mm","cmc":"1,9 µm"},{"name":"- 0,002 mm","range":"0 mm to 25 mm","cmc":"1,6 µm"},{"name":"- 0,002 mm","range":"0 mm to 50 mm","cmc":"1,7 µm"},{"name":"- 0,002 mm","range":"0 mm to 75 mm","cmc":"1,9 µm"},{"name":"- 0,002 mm","range":"0 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,005 mm","range":"0 mm to 50 mm","cmc":"3,2 µm"},{"name":"- 0,005 mm","range":"0 mm to 75 mm","cmc":"3,3 µm"},{"name":"- 0,005 mm","range":"0 mm to 100 mm","cmc":"3,4 µm"},{"name":"- 0,01 mm","range":"0 mm to 50 mm","cmc":"5,9 µm"},{"name":"- 0,01 mm","range":"0 mm to 100 mm","cmc":"6,0 µm"}],"technique":"Procedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- 0,001 mm 0 mm do 25 mm CMC 1,2 µm\n- 0,001 mm 0 mm do 50 mm CMC 1,4 µm\n- 0,001 mm 0 mm do 75 mm CMC 1,6 µm\n- 0,001 mm 0 mm do 100 mm CMC 1,9 µm\n- 0,002 mm 0 mm do 25 mm CMC 1,6 µm\n- 0,002 mm 0 mm do 50 mm CMC 1,7 µm\n- 0,002 mm 0 mm do 75 mm CMC 1,9 µm\n- 0,002 mm 0 mm do 100 mm CMC 2,1 µm\n- 0,005 mm 0 mm do 50 mm CMC 3,2 µm\n- 0,005 mm 0 mm do 75 mm CMC 3,3 µm\n- 0,005 mm 0 mm do 100 mm CMC 3,4 µm\n- 0,01 mm 0 mm do 50 mm CMC 5,9 µm\n- 0,01 mm 0 mm do 100 mm CMC 6,0 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-10-LW-AK-02","norm_bases":["IW-10-LW-AK-02"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Grubościomierze czujnikowe z czujnikiem cyfrowym o rozdzielczości: Wzorcowanie — Długość\nZakres:\n- 0,001 mm 0 mm do 25 mm CMC 1,2 µm\n- 0,001 mm 0 mm do 50 mm CMC 1,4 µm\n- 0,001 mm 0 mm do 75 mm CMC 1,6 µm\n- 0,001 mm 0 mm do 100 mm CMC 1,9 µm\n- 0,002 mm 0 mm do 25 mm CMC 1,6 µm\n- 0,002 mm 0 mm do 50 mm CMC 1,7 µm\n- 0,002 mm 0 mm do 75 mm CMC 1,9 µm\n- 0,002 mm 0 mm do 100 mm CMC 2,1 µm\n- 0,005 mm 0 mm do 50 mm CMC 3,2 µm\n- 0,005 mm 0 mm do 75 mm CMC 3,3 µm\n- 0,005 mm 0 mm do 100 mm CMC 3,4 µm\n- 0,01 mm 0 mm do 50 mm CMC 5,9 µm\n- 0,01 mm 0 mm do 100 mm CMC 6,0 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-10-LW-AK-02 Grubosciomierze czujnikowe z czujnikiem cyfrowym o rozdzielczosci: Wzorcowanie — Dlugosc\nZakres:\n- 0,001 mm 0 mm do 25 mm CMC 1,2 µm\n- 0,001 mm 0 mm do 50 mm CMC 1,4 µm\n- 0,001 mm 0 mm do 75 mm CMC 1,6 µm\n- 0,001 mm 0 mm do 100 mm CMC 1,9 µm\n- 0,002 mm 0 mm do 25 mm CMC 1,6 µm\n- 0,002 mm 0 mm do 50 mm CMC 1,7 µm\n- 0,002 mm 0 mm do 75 mm CMC 1,9 µm\n- 0,002 mm 0 mm do 100 mm CMC 2,1 µm\n- 0,005 mm 0 mm do 50 mm CMC 3,2 µm\n- 0,005 mm 0 mm do 75 mm CMC 3,3 µm\n- 0,005 mm 0 mm do 100 mm CMC 3,4 µm\n- 0,01 mm 0 mm do 50 mm CMC 5,9 µm\n- 0,01 mm 0 mm do 100 mm CMC 6,0 µm\nProcedura wewnetrzna; przy uzyciu plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-10-LW-AK-02","search_en":"Dial thickness gauges with a digital indicator, resolution: Calibration — Length Internal procedure; using gauge blocks; At permanent location (S) Length Internal procedure using gauge blocks At permanent location (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm Internal procedure IW-10-LW-AK-02","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":55,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-10-LW-AK-02","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- 0,001 mm","range":"0 mm bis 25 mm","cmc":"1,2 µm"},{"name":"- 0,001 mm","range":"0 mm bis 50 mm","cmc":"1,4 µm"},{"name":"- 0,001 mm","range":"0 mm to 75 mm","cmc":"1,6 µm"},{"name":"- 0,001 mm","range":"0 mm to 100 mm","cmc":"1,9 µm"},{"name":"- 0,002 mm","range":"0 mm bis 25 mm","cmc":"1,6 µm"},{"name":"- 0,002 mm","range":"0 mm bis 50 mm","cmc":"1,7 µm"},{"name":"- 0,002 mm","range":"0 mm to 75 mm","cmc":"1,9 µm"},{"name":"- 0,002 mm","range":"0 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,005 mm","range":"0 mm bis 50 mm","cmc":"3,2 µm"},{"name":"- 0,005 mm","range":"0 mm to 75 mm","cmc":"3,3 µm"},{"name":"- 0,005 mm","range":"0 mm to 100 mm","cmc":"3,4 µm"},{"name":"- 0,01 mm","range":"0 mm bis 50 mm","cmc":"5,9 µm"},{"name":"- 0,01 mm","range":"0 mm to 100 mm","cmc":"6,0 µm"}],"reference_de":"Internes Verfahren IW-10-LW-AK-02","regulatory_area_de":"Länge","search_de":"Dickenmessgeräte mit digitaler Messuhr mit einer Auflösung von: Kalibrierung — Länge Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren mit Parallelendmaßen Am festen Standort (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm Internes Verfahren IW-10-LW-AK-02","technique_de":"Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Dickenmessgeräte mit digitaler Messuhr mit einer Auflösung von:","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 0,001 mm","range":"0 mm 至 25 mm","cmc":"1,2 µm"},{"name":"- 0,001 mm","range":"0 mm 至 50 mm","cmc":"1,4 µm"},{"name":"- 0,001 mm","range":"0 mm to 75 mm","cmc":"1,6 µm"},{"name":"- 0,001 mm","range":"0 mm to 100 mm","cmc":"1,9 µm"},{"name":"- 0,002 mm","range":"0 mm 至 25 mm","cmc":"1,6 µm"},{"name":"- 0,002 mm","range":"0 mm 至 50 mm","cmc":"1,7 µm"},{"name":"- 0,002 mm","range":"0 mm to 75 mm","cmc":"1,9 µm"},{"name":"- 0,002 mm","range":"0 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,005 mm","range":"0 mm 至 50 mm","cmc":"3,2 µm"},{"name":"- 0,005 mm","range":"0 mm to 75 mm","cmc":"3,3 µm"},{"name":"- 0,005 mm","range":"0 mm to 100 mm","cmc":"3,4 µm"},{"name":"- 0,01 mm","range":"0 mm 至 50 mm","cmc":"5,9 µm"},{"name":"- 0,01 mm","range":"0 mm to 100 mm","cmc":"6,0 µm"}],"reference_zh":"内部程序 IW-10-LW-AK-02","regulatory_area_zh":"长度","search_zh":"带数显指示表的指示式测厚仪，分辨力： 校准 — 长度 内部程序；使用量块；在固定地点 (S) 长度 内部程序 使用量块 在固定地点 (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm 内部程序 IW-10-LW-AK-02","technique_zh":"内部程序；使用量块；在固定地点 (S)","techniques_zh":["内部程序","使用量块","在固定地点 (S)"],"test_object_zh":"带数显指示表的指示式测厚仪，分辨力：","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- 0,001 mm","range":"0 mm do 25 mm","cmc":"1,2 µm"},{"name":"- 0,001 mm","range":"0 mm do 50 mm","cmc":"1,4 µm"},{"name":"- 0,001 mm","range":"0 mm to 75 mm","cmc":"1,6 µm"},{"name":"- 0,001 mm","range":"0 mm to 100 mm","cmc":"1,9 µm"},{"name":"- 0,002 mm","range":"0 mm do 25 mm","cmc":"1,6 µm"},{"name":"- 0,002 mm","range":"0 mm do 50 mm","cmc":"1,7 µm"},{"name":"- 0,002 mm","range":"0 mm to 75 mm","cmc":"1,9 µm"},{"name":"- 0,002 mm","range":"0 mm to 100 mm","cmc":"2,1 µm"},{"name":"- 0,005 mm","range":"0 mm do 50 mm","cmc":"3,2 µm"},{"name":"- 0,005 mm","range":"0 mm to 75 mm","cmc":"3,3 µm"},{"name":"- 0,005 mm","range":"0 mm to 100 mm","cmc":"3,4 µm"},{"name":"- 0,01 mm","range":"0 mm do 50 mm","cmc":"5,9 µm"},{"name":"- 0,01 mm","range":"0 mm to 100 mm","cmc":"6,0 µm"}],"reference_cs":"Vnitřní postup IW-10-LW-AK-02","regulatory_area_cs":"Délka","search_cs":"Tloušťkoměry s digitálním úchylkoměrem s rozlišením: Kalibrace — Délka Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí koncových měrek Ve stálé lokalitě (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm Vnitřní postup IW-10-LW-AK-02","technique_cs":"Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Tloušťkoměry s digitálním úchylkoměrem s rozlišením:"},{"_id":"912e6ccfc05d697267db4eca","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Macki zewnętrzne","test_object_en":"External calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 200 mm","cmc":"3,5 µm"}],"parameters_en":[{"name":"","range":"0 mm to 200 mm","cmc":"3,5 µm"}],"technique":"Procedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 200 mm CMC 3,5 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-10-LW-AK-03","norm_bases":["IW-10-LW-AK-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Macki zewnętrzne Wzorcowanie — Długość\n0 mm do 200 mm CMC 3,5 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-10-LW-AK-03 Macki zewnetrzne Wzorcowanie — Dlugosc\n0 mm do 200 mm CMC 3,5 µm\nProcedura wewnetrzna; przy uzyciu plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-10-LW-AK-03","search_en":"External calipers Calibration — Length Internal procedure; using gauge blocks; At permanent location (S) Length Internal procedure using gauge blocks At permanent location (S) Internal procedure IW-10-LW-AK-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":56,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-10-LW-AK-03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 200 mm","cmc":"3,5 µm"}],"reference_de":"Internes Verfahren IW-10-LW-AK-03","regulatory_area_de":"Länge","search_de":"Außentaster Kalibrierung — Länge Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW-10-LW-AK-03","technique_de":"Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Außentaster","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 200 mm","cmc":"3,5 µm"}],"reference_zh":"内部程序 IW-10-LW-AK-03","regulatory_area_zh":"长度","search_zh":"外卡钳 校准 — 长度 内部程序；使用量块；在固定地点 (S) 长度 内部程序 使用量块 在固定地点 (S) 内部程序 IW-10-LW-AK-03","technique_zh":"内部程序；使用量块；在固定地点 (S)","techniques_zh":["内部程序","使用量块","在固定地点 (S)"],"test_object_zh":"外卡钳","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 200 mm","cmc":"3,5 µm"}],"reference_cs":"Vnitřní postup IW-10-LW-AK-03","regulatory_area_cs":"Délka","search_cs":"Vnější odpichy Kalibrace — Délka Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW-10-LW-AK-03","technique_cs":"Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Vnější odpichy"},{"_id":"f877e453a137671fd995050f","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Macki wewnętrzne","test_object_en":"Internal calipers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"2 mm do 25 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,3 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"2,3 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"4,3 µm"}],"parameters_en":[{"name":"","range":"2 mm do 25 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm to 50 mm","cmc":"1,3 µm"},{"name":"","range":"50 mm to 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm to 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"2,3 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"4,3 µm"}],"technique":"Procedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n2 mm do 25 mm CMC 1,1 µm\n25 mm do 50 mm CMC 1,3 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 150 mm CMC 2,3 µm\n150 mm do 200 mm CMC 3,0 µm\n200 mm do 250 mm CMC 3,7 µm\n250 mm do 300 mm CMC 4,3 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-10-LW-AK-03","norm_bases":["IW-10-LW-AK-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Macki wewnętrzne Wzorcowanie — Długość\nZakres:\n2 mm do 25 mm CMC 1,1 µm\n25 mm do 50 mm CMC 1,3 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 150 mm CMC 2,3 µm\n150 mm do 200 mm CMC 3,0 µm\n200 mm do 250 mm CMC 3,7 µm\n250 mm do 300 mm CMC 4,3 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-10-LW-AK-03 Macki wewnetrzne Wzorcowanie — Dlugosc\nZakres:\n2 mm do 25 mm CMC 1,1 µm\n25 mm do 50 mm CMC 1,3 µm\n50 mm do 75 mm CMC 1,5 µm\n75 mm do 100 mm CMC 1,8 µm\n100 mm do 150 mm CMC 2,3 µm\n150 mm do 200 mm CMC 3,0 µm\n200 mm do 250 mm CMC 3,7 µm\n250 mm do 300 mm CMC 4,3 µm\nProcedura wewnetrzna; przy uzyciu plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-10-LW-AK-03","search_en":"Internal calipers Calibration — Length Internal procedure; using gauge blocks; At permanent location (S) Length Internal procedure using gauge blocks At permanent location (S) Internal procedure IW-10-LW-AK-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":57,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-10-LW-AK-03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"2 mm do 25 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm bis 50 mm","cmc":"1,3 µm"},{"name":"","range":"50 mm bis 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm bis 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"2,3 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"4,3 µm"}],"reference_de":"Internes Verfahren IW-10-LW-AK-03","regulatory_area_de":"Länge","search_de":"Innentaster Kalibrierung — Länge Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren mit Parallelendmaßen Am festen Standort (S) Internes Verfahren IW-10-LW-AK-03","technique_de":"Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Innentaster","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"2 mm do 25 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm 至 50 mm","cmc":"1,3 µm"},{"name":"","range":"50 mm 至 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm 至 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"2,3 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"4,3 µm"}],"reference_zh":"内部程序 IW-10-LW-AK-03","regulatory_area_zh":"长度","search_zh":"内卡钳 校准 — 长度 内部程序；使用量块；在固定地点 (S) 长度 内部程序 使用量块 在固定地点 (S) 内部程序 IW-10-LW-AK-03","technique_zh":"内部程序；使用量块；在固定地点 (S)","techniques_zh":["内部程序","使用量块","在固定地点 (S)"],"test_object_zh":"内卡钳","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"2 mm do 25 mm","cmc":"1,1 µm"},{"name":"","range":"25 mm do 50 mm","cmc":"1,3 µm"},{"name":"","range":"50 mm do 75 mm","cmc":"1,5 µm"},{"name":"","range":"75 mm do 100 mm","cmc":"1,8 µm"},{"name":"","range":"100 mm do 150 mm","cmc":"2,3 µm"},{"name":"","range":"150 mm do 200 mm","cmc":"3,0 µm"},{"name":"","range":"200 mm do 250 mm","cmc":"3,7 µm"},{"name":"","range":"250 mm do 300 mm","cmc":"4,3 µm"}],"reference_cs":"Vnitřní postup IW-10-LW-AK-03","regulatory_area_cs":"Délka","search_cs":"Vnitřní odpichy Kalibrace — Délka Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí koncových měrek Ve stálé lokalitě (S) Vnitřní postup IW-10-LW-AK-03","technique_cs":"Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Vnitřní odpichy"},{"_id":"46c0ac4d47536ebc08378a65","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Szczelinomierze listkowe","test_object_en":"Leaf feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,01 mm do 10,00 mm","cmc":"4,9 µm"}],"parameters_en":[{"name":"","range":"0,01 mm to 10,00 mm","cmc":"4,9 µm"}],"technique":"Procedura wewnętrzna; przy użyciu mikrometru cyfrowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; using a digital micrometer; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu mikrometru cyfrowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using a digital micrometer","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,01 mm do 10,00 mm CMC 4,9 µm\nProcedura wewnętrzna; przy użyciu mikrometru cyfrowego; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-10-LW-AK-04","norm_bases":["IW-10-LW-AK-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze listkowe Wzorcowanie — Długość\n0,01 mm do 10,00 mm CMC 4,9 µm\nProcedura wewnętrzna; przy użyciu mikrometru cyfrowego; W stałej lokalizacji (S) Procedura wewnętrzna IW-10-LW-AK-04 Szczelinomierze listkowe Wzorcowanie — Dlugosc\n0,01 mm do 10,00 mm CMC 4,9 µm\nProcedura wewnetrzna; przy uzyciu mikrometru cyfrowego; W stalej lokalizacji (S) Procedura wewnetrzna IW-10-LW-AK-04","search_en":"Leaf feeler gauges Calibration — Length Internal procedure; using a digital micrometer; At permanent location (S) Length Internal procedure using a digital micrometer At permanent location (S) Internal procedure IW-10-LW-AK-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":58,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-10-LW-AK-04","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,01 mm to 10,00 mm","cmc":"4,9 µm"}],"reference_de":"Internes Verfahren IW-10-LW-AK-04","regulatory_area_de":"Länge","search_de":"Fühlerlehren Kalibrierung — Länge Internes Verfahren; mit einer digitalen Messschraube; Am festen Standort (S) Länge Internes Verfahren mit einer digitalen Messschraube Am festen Standort (S) Internes Verfahren IW-10-LW-AK-04","technique_de":"Internes Verfahren; mit einer digitalen Messschraube; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit einer digitalen Messschraube","Am festen Standort (S)"],"test_object_de":"Fühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,01 mm to 10,00 mm","cmc":"4,9 µm"}],"reference_zh":"内部程序 IW-10-LW-AK-04","regulatory_area_zh":"长度","search_zh":"塞尺 校准 — 长度 内部程序；使用数显千分尺；在固定地点 (S) 长度 内部程序 使用数显千分尺 在固定地点 (S) 内部程序 IW-10-LW-AK-04","technique_zh":"内部程序；使用数显千分尺；在固定地点 (S)","techniques_zh":["内部程序","使用数显千分尺","在固定地点 (S)"],"test_object_zh":"塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,01 mm to 10,00 mm","cmc":"4,9 µm"}],"reference_cs":"Vnitřní postup IW-10-LW-AK-04","regulatory_area_cs":"Délka","search_cs":"Spárové měrky listové Kalibrace — Délka Vnitřní postup; pomocí digitálního mikrometru; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí digitálního mikrometru Ve stálé lokalitě (S) Vnitřní postup IW-10-LW-AK-04","technique_cs":"Vnitřní postup; pomocí digitálního mikrometru; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí digitálního mikrometru","Ve stálé lokalitě (S)"],"test_object_cs":"Spárové měrky listové"},{"_id":"bfed36d3ec61438cb86e2a8b","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Kątowniki 90° dwuramienne","test_object_en":"90° try squares","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"pomiar odchyłki - płaskości","range":"długość ramienia do 500 mm","cmc":"4,2 µm"},{"name":"pomiar odchyłki - prostoliniowości","range":"długość ramienia do 500 mm","cmc":"4,2 µm"},{"name":"pomiar odchyłki - równoległości","range":"długość ramienia do 500 mm","cmc":"4,2 µm"},{"name":"pomiar odchyłki - prostopadłości","range":"długość ramienia do 500 mm","cmc":"4,2 µm"}],"parameters_en":[{"name":"deviation measurement - flatness","range":"arm length up to 500 mm","cmc":"4,2 µm"},{"name":"deviation measurement - straightness","range":"arm length up to 500 mm","cmc":"4,2 µm"},{"name":"deviation measurement - parallelism","range":"arm length up to 500 mm","cmc":"4,2 µm"},{"name":"deviation measurement - perpendicularity","range":"arm length up to 500 mm","cmc":"4,2 µm"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\npomiar odchyłki - płaskości długość ramienia do 500 mm CMC 4,2 µm\npomiar odchyłki - prostoliniowości długość ramienia do 500 mm CMC 4,2 µm\npomiar odchyłki - równoległości długość ramienia do 500 mm CMC 4,2 µm\npomiar odchyłki - prostopadłości długość ramienia do 500 mm CMC 4,2 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-03","norm_bases":["IW-9-LW-AK-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątowniki 90° dwuramienne Wzorcowanie — Długość\nZakres:\npomiar odchyłki - płaskości długość ramienia do 500 mm CMC 4,2 µm\npomiar odchyłki - prostoliniowości długość ramienia do 500 mm CMC 4,2 µm\npomiar odchyłki - równoległości długość ramienia do 500 mm CMC 4,2 µm\npomiar odchyłki - prostopadłości długość ramienia do 500 mm CMC 4,2 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-03 Katowniki 90° dwuramienne Wzorcowanie — Dlugosc\nZakres:\npomiar odchylki - plaskosci dlugosc ramienia do 500 mm CMC 4,2 µm\npomiar odchylki - prostoliniowosci dlugosc ramienia do 500 mm CMC 4,2 µm\npomiar odchylki - rownoleglosci dlugosc ramienia do 500 mm CMC 4,2 µm\npomiar odchylki - prostopadlosci dlugosc ramienia do 500 mm CMC 4,2 µm\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-03","search_en":"90° try squares Calibration — Length Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Length Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) deviation measurement - flatness deviation measurement - straightness deviation measurement - parallelism deviation measurement - perpendicularity Internal procedure IW-9-LW-AK-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":59,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-03","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Abweichungsmessung - Ebenheit","range":"Schenkellänge bis 500 mm","cmc":"4,2 µm"},{"name":"Abweichungsmessung - Geradheit","range":"Schenkellänge bis 500 mm","cmc":"4,2 µm"},{"name":"Abweichungsmessung - Parallelität","range":"Schenkellänge bis 500 mm","cmc":"4,2 µm"},{"name":"Abweichungsmessung - Rechtwinkligkeit","range":"Schenkellänge bis 500 mm","cmc":"4,2 µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-03","regulatory_area_de":"Länge","search_de":"Zweischenklige 90°-Anschlagwinkel Kalibrierung — Länge Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) Abweichungsmessung - Ebenheit Abweichungsmessung - Geradheit Abweichungsmessung - Parallelität Abweichungsmessung - Rechtwinkligkeit Internes Verfahren IW-9-LW-AK-03","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Zweischenklige 90°-Anschlagwinkel","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"偏差测量 - 平面度","range":"arm length up to 500 mm","cmc":"4,2 µm"},{"name":"偏差测量 - 直线度","range":"arm length up to 500 mm","cmc":"4,2 µm"},{"name":"偏差测量 - 平行度","range":"arm length up to 500 mm","cmc":"4,2 µm"},{"name":"偏差测量 - 垂直度","range":"arm length up to 500 mm","cmc":"4,2 µm"}],"reference_zh":"内部程序 IW-9-LW-AK-03","regulatory_area_zh":"长度","search_zh":"90° 宽座直角尺 校准 — 长度 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 长度 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) 偏差测量 - 平面度 偏差测量 - 直线度 偏差测量 - 平行度 偏差测量 - 垂直度 内部程序 IW-9-LW-AK-03","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"90° 宽座直角尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"měření odchylky - rovinnosti","range":"arm length up to 500 mm","cmc":"4,2 µm"},{"name":"měření odchylky - přímosti","range":"arm length up to 500 mm","cmc":"4,2 µm"},{"name":"měření odchylky - rovnoběžnosti","range":"arm length up to 500 mm","cmc":"4,2 µm"},{"name":"měření odchylky - kolmosti","range":"arm length up to 500 mm","cmc":"4,2 µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-03","regulatory_area_cs":"Délka","search_cs":"Dvouramenné úhelníky 90° Kalibrace — Délka Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) měření odchylky - rovinnosti měření odchylky - přímosti měření odchylky - rovnoběžnosti měření odchylky - kolmosti Vnitřní postup IW-9-LW-AK-03","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Dvouramenné úhelníky 90°"},{"_id":"641178c40cc35e8c26ee1104","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Kątowniki walcowe 90°","test_object_en":"90° cylindrical squares","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"pomiar odchyłki - prostoliniowości","range":"0 mm do 400 mm","cmc":"4,2 µm"},{"name":"pomiar odchyłki - prostopadłości","range":"0 mm do 400 mm","cmc":"4,2 µm"}],"parameters_en":[{"name":"deviation measurement - straightness","range":"0 mm to 400 mm","cmc":"4,2 µm"},{"name":"deviation measurement - perpendicularity","range":"0 mm to 400 mm","cmc":"4,2 µm"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\npomiar odchyłki - prostoliniowości 0 mm do 400 mm CMC 4,2 µm\npomiar odchyłki - prostopadłości 0 mm do 400 mm CMC 4,2 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-04","norm_bases":["IW-9-LW-AK-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątowniki walcowe 90° Wzorcowanie — Długość\nZakres:\npomiar odchyłki - prostoliniowości 0 mm do 400 mm CMC 4,2 µm\npomiar odchyłki - prostopadłości 0 mm do 400 mm CMC 4,2 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-04 Katowniki walcowe 90° Wzorcowanie — Dlugosc\nZakres:\npomiar odchylki - prostoliniowosci 0 mm do 400 mm CMC 4,2 µm\npomiar odchylki - prostopadlosci 0 mm do 400 mm CMC 4,2 µm\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-04","search_en":"90° cylindrical squares Calibration — Length Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Length Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) deviation measurement - straightness deviation measurement - perpendicularity Internal procedure IW-9-LW-AK-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":60,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-04","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"Abweichungsmessung - Geradheit","range":"0 mm to 400 mm","cmc":"4,2 µm"},{"name":"Abweichungsmessung - Rechtwinkligkeit","range":"0 mm to 400 mm","cmc":"4,2 µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-04","regulatory_area_de":"Länge","search_de":"Zylinderwinkel 90° Kalibrierung — Länge Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) Abweichungsmessung - Geradheit Abweichungsmessung - Rechtwinkligkeit Internes Verfahren IW-9-LW-AK-04","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Zylinderwinkel 90°","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"偏差测量 - 直线度","range":"0 mm to 400 mm","cmc":"4,2 µm"},{"name":"偏差测量 - 垂直度","range":"0 mm to 400 mm","cmc":"4,2 µm"}],"reference_zh":"内部程序 IW-9-LW-AK-04","regulatory_area_zh":"长度","search_zh":"圆柱角尺 90° 校准 — 长度 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 长度 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) 偏差测量 - 直线度 偏差测量 - 垂直度 内部程序 IW-9-LW-AK-04","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"圆柱角尺 90°","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"měření odchylky - přímosti","range":"0 mm to 400 mm","cmc":"4,2 µm"},{"name":"měření odchylky - kolmosti","range":"0 mm to 400 mm","cmc":"4,2 µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-04","regulatory_area_cs":"Délka","search_cs":"Válcové úhelníky 90° Kalibrace — Délka Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) měření odchylky - přímosti měření odchylky - kolmosti Vnitřní postup IW-9-LW-AK-04","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Válcové úhelníky 90°"},{"_id":"f8ec23cd061587180e242d47","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Średnicówki czujnikowe czujnikiem analogowym o wartości działki elementarnej:","test_object_en":"Dial bore gauges with an analogue indicator, scale interval:","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- 0,001 mm","range":"0 mm do 35 mm","cmc":"3,7 µm"},{"name":"- 0,001 mm","range":"od 35 mm do 60 mm","cmc":"3,8 µm"},{"name":"- 0,001 mm","range":"od 50 mm do 150 mm","cmc":"4,3 µm"},{"name":"- 0,001 mm","range":"od 150 mm do 250 mm","cmc":"5,2 µm"},{"name":"- 0,001 mm","range":"od 250 mm do 500 mm","cmc":"7,9 µm"},{"name":"- 0,002 mm","range":"0 mm do 35 mm","cmc":"3,7 µm"},{"name":"- 0,002 mm","range":"od 35 mm do 60 mm","cmc":"3,8 µm"},{"name":"- 0,002 mm","range":"od 50 mm do 150 mm","cmc":"4,3 µm"},{"name":"- 0,002 mm","range":"od 150 mm do 250 mm","cmc":"5,2 µm"},{"name":"- 0,002 mm","range":"od 250 mm do 500 mm","cmc":"7,9 µm"},{"name":"- 0,005 mm","range":"0 mm do 35 mm","cmc":"3,8 µm"},{"name":"- 0,005 mm","range":"od 35 mm do 60 mm","cmc":"3,8 µm"},{"name":"- 0,005 mm","range":"od 50 mm do 150 mm","cmc":"4,4 µm"},{"name":"- 0,005 mm","range":"od 150 mm do 250 mm","cmc":"5,2 µm"},{"name":"- 0,005 mm","range":"od 250 mm do 500 mm","cmc":"7,9 µm"},{"name":"- 0,01 mm","range":"0 mm do 35 mm","cmc":"4,4 µm"},{"name":"- 0,01 mm","range":"od 35 mm do 60 mm","cmc":"4,4 µm"},{"name":"- 0,01 mm","range":"od 50 mm do 150 mm","cmc":"4,9 µm"},{"name":"- 0,01 mm","range":"od 150 mm do 250 mm","cmc":"5,7 µm"},{"name":"- 0,01 mm","range":"od 250 mm do 500 mm","cmc":"8,2 µm"},{"name":"- 0,1 mm","range":"0 mm do 35 mm","cmc":"10,8 µm"},{"name":"- 0,1 mm","range":"od 35 mm do 60 mm","cmc":"10,9 µm"},{"name":"- 0,1 mm","range":"od 50 mm do 150 mm","cmc":"11,0 µm"},{"name":"- 0,1 mm","range":"od 150 mm do 250 mm","cmc":"11,4 µm"},{"name":"- 0,1 mm","range":"od 250 mm do 500 mm","cmc":"12,9 µm"}],"parameters_en":[{"name":"- 0,001 mm","range":"0 mm to 35 mm","cmc":"3,7 µm"},{"name":"- 0,001 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,001 mm","range":"od 50 mm to 150 mm","cmc":"4,3 µm"},{"name":"- 0,001 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,001 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,002 mm","range":"0 mm to 35 mm","cmc":"3,7 µm"},{"name":"- 0,002 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,002 mm","range":"od 50 mm to 150 mm","cmc":"4,3 µm"},{"name":"- 0,002 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,002 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,005 mm","range":"0 mm to 35 mm","cmc":"3,8 µm"},{"name":"- 0,005 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,005 mm","range":"od 50 mm to 150 mm","cmc":"4,4 µm"},{"name":"- 0,005 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,005 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,01 mm","range":"0 mm to 35 mm","cmc":"4,4 µm"},{"name":"- 0,01 mm","range":"od 35 mm to 60 mm","cmc":"4,4 µm"},{"name":"- 0,01 mm","range":"od 50 mm to 150 mm","cmc":"4,9 µm"},{"name":"- 0,01 mm","range":"od 150 mm to 250 mm","cmc":"5,7 µm"},{"name":"- 0,01 mm","range":"od 250 mm to 500 mm","cmc":"8,2 µm"},{"name":"- 0,1 mm","range":"0 mm to 35 mm","cmc":"10,8 µm"},{"name":"- 0,1 mm","range":"od 35 mm to 60 mm","cmc":"10,9 µm"},{"name":"- 0,1 mm","range":"od 50 mm to 150 mm","cmc":"11,0 µm"},{"name":"- 0,1 mm","range":"od 150 mm to 250 mm","cmc":"11,4 µm"},{"name":"- 0,1 mm","range":"od 250 mm to 500 mm","cmc":"12,9 µm"}],"technique":"Procedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- 0,001 mm 0 mm do 35 mm CMC 3,7 µm\n- 0,001 mm od 35 mm do 60 mm CMC 3,8 µm\n- 0,001 mm od 50 mm do 150 mm CMC 4,3 µm\n- 0,001 mm od 150 mm do 250 mm CMC 5,2 µm\n- 0,001 mm od 250 mm do 500 mm CMC 7,9 µm\n- 0,002 mm 0 mm do 35 mm CMC 3,7 µm\n- 0,002 mm od 35 mm do 60 mm CMC 3,8 µm\n- 0,002 mm od 50 mm do 150 mm CMC 4,3 µm\n- 0,002 mm od 150 mm do 250 mm CMC 5,2 µm\n- 0,002 mm od 250 mm do 500 mm CMC 7,9 µm\n- 0,005 mm 0 mm do 35 mm CMC 3,8 µm\n- 0,005 mm od 35 mm do 60 mm CMC 3,8 µm\n- 0,005 mm od 50 mm do 150 mm CMC 4,4 µm\n- 0,005 mm od 150 mm do 250 mm CMC 5,2 µm\n- 0,005 mm od 250 mm do 500 mm CMC 7,9 µm\n- 0,01 mm 0 mm do 35 mm CMC 4,4 µm\n- 0,01 mm od 35 mm do 60 mm CMC 4,4 µm\n- 0,01 mm od 50 mm do 150 mm CMC 4,9 µm\n- 0,01 mm od 150 mm do 250 mm CMC 5,7 µm\n- 0,01 mm od 250 mm do 500 mm CMC 8,2 µm\n- 0,1 mm 0 mm do 35 mm CMC 10,8 µm\n- 0,1 mm od 35 mm do 60 mm CMC 10,9 µm\n- 0,1 mm od 50 mm do 150 mm CMC 11,0 µm\n- 0,1 mm od 150 mm do 250 mm CMC 11,4 µm\n- 0,1 mm od 250 mm do 500 mm CMC 12,9 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-10-LW-AK-05","norm_bases":["IW-10-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki czujnikowe czujnikiem analogowym o wartości działki elementarnej: Wzorcowanie — Długość\nZakres:\n- 0,001 mm 0 mm do 35 mm CMC 3,7 µm\n- 0,001 mm od 35 mm do 60 mm CMC 3,8 µm\n- 0,001 mm od 50 mm do 150 mm CMC 4,3 µm\n- 0,001 mm od 150 mm do 250 mm CMC 5,2 µm\n- 0,001 mm od 250 mm do 500 mm CMC 7,9 µm\n- 0,002 mm 0 mm do 35 mm CMC 3,7 µm\n- 0,002 mm od 35 mm do 60 mm CMC 3,8 µm\n- 0,002 mm od 50 mm do 150 mm CMC 4,3 µm\n- 0,002 mm od 150 mm do 250 mm CMC 5,2 µm\n- 0,002 mm od 250 mm do 500 mm CMC 7,9 µm\n- 0,005 mm 0 mm do 35 mm CMC 3,8 µm\n- 0,005 mm od 35 mm do 60 mm CMC 3,8 µm\n- 0,005 mm od 50 mm do 150 mm CMC 4,4 µm\n- 0,005 mm od 150 mm do 250 mm CMC 5,2 µm\n- 0,005 mm od 250 mm do 500 mm CMC 7,9 µm\n- 0,01 mm 0 mm do 35 mm CMC 4,4 µm\n- 0,01 mm od 35 mm do 60 mm CMC 4,4 µm\n- 0,01 mm od 50 mm do 150 mm CMC 4,9 µm\n- 0,01 mm od 150 mm do 250 mm CMC 5,7 µm\n- 0,01 mm od 250 mm do 500 mm CMC 8,2 µm\n- 0,1 mm 0 mm do 35 mm CMC 10,8 µm\n- 0,1 mm od 35 mm do 60 mm CMC 10,9 µm\n- 0,1 mm od 50 mm do 150 mm CMC 11,0 µm\n- 0,1 mm od 150 mm do 250 mm CMC 11,4 µm\n- 0,1 mm od 250 mm do 500 mm CMC 12,9 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-10-LW-AK-05 Srednicowki czujnikowe czujnikiem analogowym o wartosci dzialki elementarnej: Wzorcowanie — Dlugosc\nZakres:\n- 0,001 mm 0 mm do 35 mm CMC 3,7 µm\n- 0,001 mm od 35 mm do 60 mm CMC 3,8 µm\n- 0,001 mm od 50 mm do 150 mm CMC 4,3 µm\n- 0,001 mm od 150 mm do 250 mm CMC 5,2 µm\n- 0,001 mm od 250 mm do 500 mm CMC 7,9 µm\n- 0,002 mm 0 mm do 35 mm CMC 3,7 µm\n- 0,002 mm od 35 mm do 60 mm CMC 3,8 µm\n- 0,002 mm od 50 mm do 150 mm CMC 4,3 µm\n- 0,002 mm od 150 mm do 250 mm CMC 5,2 µm\n- 0,002 mm od 250 mm do 500 mm CMC 7,9 µm\n- 0,005 mm 0 mm do 35 mm CMC 3,8 µm\n- 0,005 mm od 35 mm do 60 mm CMC 3,8 µm\n- 0,005 mm od 50 mm do 150 mm CMC 4,4 µm\n- 0,005 mm od 150 mm do 250 mm CMC 5,2 µm\n- 0,005 mm od 250 mm do 500 mm CMC 7,9 µm\n- 0,01 mm 0 mm do 35 mm CMC 4,4 µm\n- 0,01 mm od 35 mm do 60 mm CMC 4,4 µm\n- 0,01 mm od 50 mm do 150 mm CMC 4,9 µm\n- 0,01 mm od 150 mm do 250 mm CMC 5,7 µm\n- 0,01 mm od 250 mm do 500 mm CMC 8,2 µm\n- 0,1 mm 0 mm do 35 mm CMC 10,8 µm\n- 0,1 mm od 35 mm do 60 mm CMC 10,9 µm\n- 0,1 mm od 50 mm do 150 mm CMC 11,0 µm\n- 0,1 mm od 150 mm do 250 mm CMC 11,4 µm\n- 0,1 mm od 250 mm do 500 mm CMC 12,9 µm\nProcedura wewnetrzna; przy uzyciu plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-10-LW-AK-05","search_en":"Dial bore gauges with an analogue indicator, scale interval: Calibration — Length Internal procedure; using gauge blocks; At permanent location (S) Length Internal procedure using gauge blocks At permanent location (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,1 mm - 0,1 mm - 0,1 mm - 0,1 mm - 0,1 mm Internal procedure IW-10-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":61,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-10-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- 0,001 mm","range":"0 mm to 35 mm","cmc":"3,7 µm"},{"name":"- 0,001 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,001 mm","range":"od 50 mm to 150 mm","cmc":"4,3 µm"},{"name":"- 0,001 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,001 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,002 mm","range":"0 mm to 35 mm","cmc":"3,7 µm"},{"name":"- 0,002 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,002 mm","range":"od 50 mm to 150 mm","cmc":"4,3 µm"},{"name":"- 0,002 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,002 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,005 mm","range":"0 mm to 35 mm","cmc":"3,8 µm"},{"name":"- 0,005 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,005 mm","range":"od 50 mm to 150 mm","cmc":"4,4 µm"},{"name":"- 0,005 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,005 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,01 mm","range":"0 mm to 35 mm","cmc":"4,4 µm"},{"name":"- 0,01 mm","range":"od 35 mm to 60 mm","cmc":"4,4 µm"},{"name":"- 0,01 mm","range":"od 50 mm to 150 mm","cmc":"4,9 µm"},{"name":"- 0,01 mm","range":"od 150 mm to 250 mm","cmc":"5,7 µm"},{"name":"- 0,01 mm","range":"od 250 mm to 500 mm","cmc":"8,2 µm"},{"name":"- 0,1 mm","range":"0 mm to 35 mm","cmc":"10,8 µm"},{"name":"- 0,1 mm","range":"od 35 mm to 60 mm","cmc":"10,9 µm"},{"name":"- 0,1 mm","range":"od 50 mm to 150 mm","cmc":"11,0 µm"},{"name":"- 0,1 mm","range":"od 150 mm to 250 mm","cmc":"11,4 µm"},{"name":"- 0,1 mm","range":"od 250 mm to 500 mm","cmc":"12,9 µm"}],"reference_de":"Internes Verfahren IW-10-LW-AK-05","regulatory_area_de":"Länge","search_de":"Innenfeinmessgeräte mit analoger Messuhr, Skalenteilungswert: Kalibrierung — Länge Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren mit Parallelendmaßen Am festen Standort (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,1 mm - 0,1 mm - 0,1 mm - 0,1 mm - 0,1 mm Internes Verfahren IW-10-LW-AK-05","technique_de":"Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Innenfeinmessgeräte mit analoger Messuhr, Skalenteilungswert:","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 0,001 mm","range":"0 mm to 35 mm","cmc":"3,7 µm"},{"name":"- 0,001 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,001 mm","range":"od 50 mm to 150 mm","cmc":"4,3 µm"},{"name":"- 0,001 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,001 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,002 mm","range":"0 mm to 35 mm","cmc":"3,7 µm"},{"name":"- 0,002 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,002 mm","range":"od 50 mm to 150 mm","cmc":"4,3 µm"},{"name":"- 0,002 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,002 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,005 mm","range":"0 mm to 35 mm","cmc":"3,8 µm"},{"name":"- 0,005 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,005 mm","range":"od 50 mm to 150 mm","cmc":"4,4 µm"},{"name":"- 0,005 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,005 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,01 mm","range":"0 mm to 35 mm","cmc":"4,4 µm"},{"name":"- 0,01 mm","range":"od 35 mm to 60 mm","cmc":"4,4 µm"},{"name":"- 0,01 mm","range":"od 50 mm to 150 mm","cmc":"4,9 µm"},{"name":"- 0,01 mm","range":"od 150 mm to 250 mm","cmc":"5,7 µm"},{"name":"- 0,01 mm","range":"od 250 mm to 500 mm","cmc":"8,2 µm"},{"name":"- 0,1 mm","range":"0 mm to 35 mm","cmc":"10,8 µm"},{"name":"- 0,1 mm","range":"od 35 mm to 60 mm","cmc":"10,9 µm"},{"name":"- 0,1 mm","range":"od 50 mm to 150 mm","cmc":"11,0 µm"},{"name":"- 0,1 mm","range":"od 150 mm to 250 mm","cmc":"11,4 µm"},{"name":"- 0,1 mm","range":"od 250 mm to 500 mm","cmc":"12,9 µm"}],"reference_zh":"内部程序 IW-10-LW-AK-05","regulatory_area_zh":"长度","search_zh":"带模拟指示表的内径指示表，分度值： 校准 — 长度 内部程序；使用量块；在固定地点 (S) 长度 内部程序 使用量块 在固定地点 (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,1 mm - 0,1 mm - 0,1 mm - 0,1 mm - 0,1 mm 内部程序 IW-10-LW-AK-05","technique_zh":"内部程序；使用量块；在固定地点 (S)","techniques_zh":["内部程序","使用量块","在固定地点 (S)"],"test_object_zh":"带模拟指示表的内径指示表，分度值：","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- 0,001 mm","range":"0 mm to 35 mm","cmc":"3,7 µm"},{"name":"- 0,001 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,001 mm","range":"od 50 mm to 150 mm","cmc":"4,3 µm"},{"name":"- 0,001 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,001 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,002 mm","range":"0 mm to 35 mm","cmc":"3,7 µm"},{"name":"- 0,002 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,002 mm","range":"od 50 mm to 150 mm","cmc":"4,3 µm"},{"name":"- 0,002 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,002 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,005 mm","range":"0 mm to 35 mm","cmc":"3,8 µm"},{"name":"- 0,005 mm","range":"od 35 mm to 60 mm","cmc":"3,8 µm"},{"name":"- 0,005 mm","range":"od 50 mm to 150 mm","cmc":"4,4 µm"},{"name":"- 0,005 mm","range":"od 150 mm to 250 mm","cmc":"5,2 µm"},{"name":"- 0,005 mm","range":"od 250 mm to 500 mm","cmc":"7,9 µm"},{"name":"- 0,01 mm","range":"0 mm to 35 mm","cmc":"4,4 µm"},{"name":"- 0,01 mm","range":"od 35 mm to 60 mm","cmc":"4,4 µm"},{"name":"- 0,01 mm","range":"od 50 mm to 150 mm","cmc":"4,9 µm"},{"name":"- 0,01 mm","range":"od 150 mm to 250 mm","cmc":"5,7 µm"},{"name":"- 0,01 mm","range":"od 250 mm to 500 mm","cmc":"8,2 µm"},{"name":"- 0,1 mm","range":"0 mm to 35 mm","cmc":"10,8 µm"},{"name":"- 0,1 mm","range":"od 35 mm to 60 mm","cmc":"10,9 µm"},{"name":"- 0,1 mm","range":"od 50 mm to 150 mm","cmc":"11,0 µm"},{"name":"- 0,1 mm","range":"od 150 mm to 250 mm","cmc":"11,4 µm"},{"name":"- 0,1 mm","range":"od 250 mm to 500 mm","cmc":"12,9 µm"}],"reference_cs":"Vnitřní postup IW-10-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Dutinoměry s analogovým úchylkoměrem s hodnotou dílku: Kalibrace — Délka Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí koncových měrek Ve stálé lokalitě (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,1 mm - 0,1 mm - 0,1 mm - 0,1 mm - 0,1 mm Vnitřní postup IW-10-LW-AK-05","technique_cs":"Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Dutinoměry s analogovým úchylkoměrem s hodnotou dílku:"},{"_id":"f66cf91684a544db19030b88","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Średnicówki czujnikowe z cyfrowym czujnikiem o rozdzielczości:","test_object_en":"Dial bore gauges with a digital indicator, resolution:","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- 0,001 mm","range":"0 mm do 35 mm","cmc":"4,1 µm"},{"name":"- 0,001 mm","range":"od 35 mm do 60 mm","cmc":"4,2 µm"},{"name":"- 0,001 mm","range":"od 50 mm do 150 mm","cmc":"4,7 µm"},{"name":"- 0,001 mm","range":"od 150 mm do 250 mm","cmc":"5,5 µm"},{"name":"- 0,001 mm","range":"od 250 mm do 500 mm","cmc":"8,1 µm"},{"name":"- 0,002 mm","range":"0 mm do 35 mm","cmc":"4,2 µm"},{"name":"- 0,002 mm","range":"od 35 mm do 60 mm","cmc":"4,3 µm"},{"name":"- 0,002 mm","range":"od 50 mm do 150 mm","cmc":"4,8 µm"},{"name":"- 0,002 mm","range":"od 150 mm do 250 mm","cmc":"5,6 µm"},{"name":"- 0,002 mm","range":"od 250 mm do 500 mm","cmc":"8,2 µm"},{"name":"- 0,005 mm","range":"0 mm do 35 mm","cmc":"5,0 µm"},{"name":"- 0,005 mm","range":"od 35 mm do 60 mm","cmc":"5,1 µm"},{"name":"- 0,005 mm","range":"od 50 mm do 150 mm","cmc":"5,5 mm"},{"name":"- 0,005 mm","range":"od 150 mm do 250 mm","cmc":"6,2 µm"},{"name":"- 0,005 mm","range":"od 250 mm do 500 mm","cmc":"8,6 µm"},{"name":"- 0,01 mm","range":"0 mm do 35 mm","cmc":"7,2 µm"},{"name":"- 0,01 mm","range":"od 35 mm do 60 mm","cmc":"7,2 µm"},{"name":"- 0,01 mm","range":"od 50 mm do 150 mm","cmc":"7,5 µm"},{"name":"- 0,01 mm","range":"od 150 mm do 250 mm","cmc":"8,0 µm"},{"name":"- 0,01 mm","range":"od 250 mm do 500 mm","cmc":"10,0 µm"},{"name":"- 0,02 mm","range":"0 mm do 35 mm","cmc":"13,5 µm"},{"name":"- 0,02 mm","range":"od 35 mm do 60 mm","cmc":"13,6 µm"},{"name":"- 0,02 mm","range":"od 50 mm do 150 mm","cmc":"13,7 µm"},{"name":"- 0,02 mm","range":"od 150 mm do 250 mm","cmc":"14,00 µm"},{"name":"- 0,02 mm","range":"od 250 mm do 500 mm","cmc":"15,2 µm"},{"name":"- 0,05 mm","range":"0 mm do 35 mm","cmc":"32,7µm"},{"name":"- 0,05 mm","range":"od 35 mm do 60 mm","cmc":"32,7 µm"},{"name":"- 0,05 mm","range":"od 50 mm do 150 mm","cmc":"32,8 µm"},{"name":"- 0,05 mm","range":"od 150 mm do 250 mm","cmc":"32,9 µm"},{"name":"- 0,05 mm","range":"od 250 mm do 500 mm","cmc":"33,5 µm"}],"parameters_en":[{"name":"- 0,001 mm","range":"0 mm to 35 mm","cmc":"4,1 µm"},{"name":"- 0,001 mm","range":"od 35 mm to 60 mm","cmc":"4,2 µm"},{"name":"- 0,001 mm","range":"od 50 mm to 150 mm","cmc":"4,7 µm"},{"name":"- 0,001 mm","range":"od 150 mm to 250 mm","cmc":"5,5 µm"},{"name":"- 0,001 mm","range":"od 250 mm to 500 mm","cmc":"8,1 µm"},{"name":"- 0,002 mm","range":"0 mm to 35 mm","cmc":"4,2 µm"},{"name":"- 0,002 mm","range":"od 35 mm to 60 mm","cmc":"4,3 µm"},{"name":"- 0,002 mm","range":"od 50 mm to 150 mm","cmc":"4,8 µm"},{"name":"- 0,002 mm","range":"od 150 mm to 250 mm","cmc":"5,6 µm"},{"name":"- 0,002 mm","range":"od 250 mm to 500 mm","cmc":"8,2 µm"},{"name":"- 0,005 mm","range":"0 mm to 35 mm","cmc":"5,0 µm"},{"name":"- 0,005 mm","range":"od 35 mm to 60 mm","cmc":"5,1 µm"},{"name":"- 0,005 mm","range":"od 50 mm to 150 mm","cmc":"5,5 mm"},{"name":"- 0,005 mm","range":"od 150 mm to 250 mm","cmc":"6,2 µm"},{"name":"- 0,005 mm","range":"od 250 mm to 500 mm","cmc":"8,6 µm"},{"name":"- 0,01 mm","range":"0 mm to 35 mm","cmc":"7,2 µm"},{"name":"- 0,01 mm","range":"od 35 mm to 60 mm","cmc":"7,2 µm"},{"name":"- 0,01 mm","range":"od 50 mm to 150 mm","cmc":"7,5 µm"},{"name":"- 0,01 mm","range":"od 150 mm to 250 mm","cmc":"8,0 µm"},{"name":"- 0,01 mm","range":"od 250 mm to 500 mm","cmc":"10,0 µm"},{"name":"- 0,02 mm","range":"0 mm to 35 mm","cmc":"13,5 µm"},{"name":"- 0,02 mm","range":"od 35 mm to 60 mm","cmc":"13,6 µm"},{"name":"- 0,02 mm","range":"od 50 mm to 150 mm","cmc":"13,7 µm"},{"name":"- 0,02 mm","range":"od 150 mm to 250 mm","cmc":"14,00 µm"},{"name":"- 0,02 mm","range":"od 250 mm to 500 mm","cmc":"15,2 µm"},{"name":"- 0,05 mm","range":"0 mm to 35 mm","cmc":"32,7µm"},{"name":"- 0,05 mm","range":"od 35 mm to 60 mm","cmc":"32,7 µm"},{"name":"- 0,05 mm","range":"od 50 mm to 150 mm","cmc":"32,8 µm"},{"name":"- 0,05 mm","range":"od 150 mm to 250 mm","cmc":"32,9 µm"},{"name":"- 0,05 mm","range":"od 250 mm to 500 mm","cmc":"33,5 µm"}],"technique":"Procedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu płytek wzorcowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- 0,001 mm 0 mm do 35 mm CMC 4,1 µm\n- 0,001 mm od 35 mm do 60 mm CMC 4,2 µm\n- 0,001 mm od 50 mm do 150 mm CMC 4,7 µm\n- 0,001 mm od 150 mm do 250 mm CMC 5,5 µm\n- 0,001 mm od 250 mm do 500 mm CMC 8,1 µm\n- 0,002 mm 0 mm do 35 mm CMC 4,2 µm\n- 0,002 mm od 35 mm do 60 mm CMC 4,3 µm\n- 0,002 mm od 50 mm do 150 mm CMC 4,8 µm\n- 0,002 mm od 150 mm do 250 mm CMC 5,6 µm\n- 0,002 mm od 250 mm do 500 mm CMC 8,2 µm\n- 0,005 mm 0 mm do 35 mm CMC 5,0 µm\n- 0,005 mm od 35 mm do 60 mm CMC 5,1 µm\n- 0,005 mm od 50 mm do 150 mm CMC 5,5 mm\n- 0,005 mm od 150 mm do 250 mm CMC 6,2 µm\n- 0,005 mm od 250 mm do 500 mm CMC 8,6 µm\n- 0,01 mm 0 mm do 35 mm CMC 7,2 µm\n- 0,01 mm od 35 mm do 60 mm CMC 7,2 µm\n- 0,01 mm od 50 mm do 150 mm CMC 7,5 µm\n- 0,01 mm od 150 mm do 250 mm CMC 8,0 µm\n- 0,01 mm od 250 mm do 500 mm CMC 10,0 µm\n- 0,02 mm 0 mm do 35 mm CMC 13,5 µm\n- 0,02 mm od 35 mm do 60 mm CMC 13,6 µm\n- 0,02 mm od 50 mm do 150 mm CMC 13,7 µm\n- 0,02 mm od 150 mm do 250 mm CMC 14,00 µm\n- 0,02 mm od 250 mm do 500 mm CMC 15,2 µm\n- 0,05 mm 0 mm do 35 mm CMC 32,7µm\n- 0,05 mm od 35 mm do 60 mm CMC 32,7 µm\n- 0,05 mm od 50 mm do 150 mm CMC 32,8 µm\n- 0,05 mm od 150 mm do 250 mm CMC 32,9 µm\n- 0,05 mm od 250 mm do 500 mm CMC 33,5 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-10-LW-AK-05","norm_bases":["IW-10-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Średnicówki czujnikowe z cyfrowym czujnikiem o rozdzielczości: Wzorcowanie — Długość\nZakres:\n- 0,001 mm 0 mm do 35 mm CMC 4,1 µm\n- 0,001 mm od 35 mm do 60 mm CMC 4,2 µm\n- 0,001 mm od 50 mm do 150 mm CMC 4,7 µm\n- 0,001 mm od 150 mm do 250 mm CMC 5,5 µm\n- 0,001 mm od 250 mm do 500 mm CMC 8,1 µm\n- 0,002 mm 0 mm do 35 mm CMC 4,2 µm\n- 0,002 mm od 35 mm do 60 mm CMC 4,3 µm\n- 0,002 mm od 50 mm do 150 mm CMC 4,8 µm\n- 0,002 mm od 150 mm do 250 mm CMC 5,6 µm\n- 0,002 mm od 250 mm do 500 mm CMC 8,2 µm\n- 0,005 mm 0 mm do 35 mm CMC 5,0 µm\n- 0,005 mm od 35 mm do 60 mm CMC 5,1 µm\n- 0,005 mm od 50 mm do 150 mm CMC 5,5 mm\n- 0,005 mm od 150 mm do 250 mm CMC 6,2 µm\n- 0,005 mm od 250 mm do 500 mm CMC 8,6 µm\n- 0,01 mm 0 mm do 35 mm CMC 7,2 µm\n- 0,01 mm od 35 mm do 60 mm CMC 7,2 µm\n- 0,01 mm od 50 mm do 150 mm CMC 7,5 µm\n- 0,01 mm od 150 mm do 250 mm CMC 8,0 µm\n- 0,01 mm od 250 mm do 500 mm CMC 10,0 µm\n- 0,02 mm 0 mm do 35 mm CMC 13,5 µm\n- 0,02 mm od 35 mm do 60 mm CMC 13,6 µm\n- 0,02 mm od 50 mm do 150 mm CMC 13,7 µm\n- 0,02 mm od 150 mm do 250 mm CMC 14,00 µm\n- 0,02 mm od 250 mm do 500 mm CMC 15,2 µm\n- 0,05 mm 0 mm do 35 mm CMC 32,7µm\n- 0,05 mm od 35 mm do 60 mm CMC 32,7 µm\n- 0,05 mm od 50 mm do 150 mm CMC 32,8 µm\n- 0,05 mm od 150 mm do 250 mm CMC 32,9 µm\n- 0,05 mm od 250 mm do 500 mm CMC 33,5 µm\nProcedura wewnętrzna; przy użyciu płytek wzorcowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-10-LW-AK-05 Srednicowki czujnikowe z cyfrowym czujnikiem o rozdzielczosci: Wzorcowanie — Dlugosc\nZakres:\n- 0,001 mm 0 mm do 35 mm CMC 4,1 µm\n- 0,001 mm od 35 mm do 60 mm CMC 4,2 µm\n- 0,001 mm od 50 mm do 150 mm CMC 4,7 µm\n- 0,001 mm od 150 mm do 250 mm CMC 5,5 µm\n- 0,001 mm od 250 mm do 500 mm CMC 8,1 µm\n- 0,002 mm 0 mm do 35 mm CMC 4,2 µm\n- 0,002 mm od 35 mm do 60 mm CMC 4,3 µm\n- 0,002 mm od 50 mm do 150 mm CMC 4,8 µm\n- 0,002 mm od 150 mm do 250 mm CMC 5,6 µm\n- 0,002 mm od 250 mm do 500 mm CMC 8,2 µm\n- 0,005 mm 0 mm do 35 mm CMC 5,0 µm\n- 0,005 mm od 35 mm do 60 mm CMC 5,1 µm\n- 0,005 mm od 50 mm do 150 mm CMC 5,5 mm\n- 0,005 mm od 150 mm do 250 mm CMC 6,2 µm\n- 0,005 mm od 250 mm do 500 mm CMC 8,6 µm\n- 0,01 mm 0 mm do 35 mm CMC 7,2 µm\n- 0,01 mm od 35 mm do 60 mm CMC 7,2 µm\n- 0,01 mm od 50 mm do 150 mm CMC 7,5 µm\n- 0,01 mm od 150 mm do 250 mm CMC 8,0 µm\n- 0,01 mm od 250 mm do 500 mm CMC 10,0 µm\n- 0,02 mm 0 mm do 35 mm CMC 13,5 µm\n- 0,02 mm od 35 mm do 60 mm CMC 13,6 µm\n- 0,02 mm od 50 mm do 150 mm CMC 13,7 µm\n- 0,02 mm od 150 mm do 250 mm CMC 14,00 µm\n- 0,02 mm od 250 mm do 500 mm CMC 15,2 µm\n- 0,05 mm 0 mm do 35 mm CMC 32,7µm\n- 0,05 mm od 35 mm do 60 mm CMC 32,7 µm\n- 0,05 mm od 50 mm do 150 mm CMC 32,8 µm\n- 0,05 mm od 150 mm do 250 mm CMC 32,9 µm\n- 0,05 mm od 250 mm do 500 mm CMC 33,5 µm\nProcedura wewnetrzna; przy uzyciu plytek wzorcowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-10-LW-AK-05","search_en":"Dial bore gauges with a digital indicator, resolution: Calibration — Length Internal procedure; using gauge blocks; At permanent location (S) Length Internal procedure using gauge blocks At permanent location (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,05 mm - 0,05 mm - 0,05 mm - 0,05 mm - 0,05 mm Internal procedure IW-10-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":62,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-10-LW-AK-05","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- 0,001 mm","range":"0 mm to 35 mm","cmc":"4,1 µm"},{"name":"- 0,001 mm","range":"od 35 mm to 60 mm","cmc":"4,2 µm"},{"name":"- 0,001 mm","range":"od 50 mm to 150 mm","cmc":"4,7 µm"},{"name":"- 0,001 mm","range":"od 150 mm to 250 mm","cmc":"5,5 µm"},{"name":"- 0,001 mm","range":"od 250 mm to 500 mm","cmc":"8,1 µm"},{"name":"- 0,002 mm","range":"0 mm to 35 mm","cmc":"4,2 µm"},{"name":"- 0,002 mm","range":"od 35 mm to 60 mm","cmc":"4,3 µm"},{"name":"- 0,002 mm","range":"od 50 mm to 150 mm","cmc":"4,8 µm"},{"name":"- 0,002 mm","range":"od 150 mm to 250 mm","cmc":"5,6 µm"},{"name":"- 0,002 mm","range":"od 250 mm to 500 mm","cmc":"8,2 µm"},{"name":"- 0,005 mm","range":"0 mm to 35 mm","cmc":"5,0 µm"},{"name":"- 0,005 mm","range":"od 35 mm to 60 mm","cmc":"5,1 µm"},{"name":"- 0,005 mm","range":"od 50 mm to 150 mm","cmc":"5,5 mm"},{"name":"- 0,005 mm","range":"od 150 mm to 250 mm","cmc":"6,2 µm"},{"name":"- 0,005 mm","range":"od 250 mm to 500 mm","cmc":"8,6 µm"},{"name":"- 0,01 mm","range":"0 mm to 35 mm","cmc":"7,2 µm"},{"name":"- 0,01 mm","range":"od 35 mm to 60 mm","cmc":"7,2 µm"},{"name":"- 0,01 mm","range":"od 50 mm to 150 mm","cmc":"7,5 µm"},{"name":"- 0,01 mm","range":"od 150 mm to 250 mm","cmc":"8,0 µm"},{"name":"- 0,01 mm","range":"od 250 mm to 500 mm","cmc":"10,0 µm"},{"name":"- 0,02 mm","range":"0 mm to 35 mm","cmc":"13,5 µm"},{"name":"- 0,02 mm","range":"od 35 mm to 60 mm","cmc":"13,6 µm"},{"name":"- 0,02 mm","range":"od 50 mm to 150 mm","cmc":"13,7 µm"},{"name":"- 0,02 mm","range":"od 150 mm to 250 mm","cmc":"14,00 µm"},{"name":"- 0,02 mm","range":"od 250 mm to 500 mm","cmc":"15,2 µm"},{"name":"- 0,05 mm","range":"0 mm to 35 mm","cmc":"32,7µm"},{"name":"- 0,05 mm","range":"od 35 mm to 60 mm","cmc":"32,7 µm"},{"name":"- 0,05 mm","range":"od 50 mm to 150 mm","cmc":"32,8 µm"},{"name":"- 0,05 mm","range":"od 150 mm to 250 mm","cmc":"32,9 µm"},{"name":"- 0,05 mm","range":"od 250 mm to 500 mm","cmc":"33,5 µm"}],"reference_de":"Internes Verfahren IW-10-LW-AK-05","regulatory_area_de":"Länge","search_de":"Innenfeinmessgeräte mit digitaler Messuhr mit einer Auflösung von: Kalibrierung — Länge Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S) Länge Internes Verfahren mit Parallelendmaßen Am festen Standort (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,05 mm - 0,05 mm - 0,05 mm - 0,05 mm - 0,05 mm Internes Verfahren IW-10-LW-AK-05","technique_de":"Internes Verfahren; mit Parallelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Parallelendmaßen","Am festen Standort (S)"],"test_object_de":"Innenfeinmessgeräte mit digitaler Messuhr mit einer Auflösung von:","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 0,001 mm","range":"0 mm to 35 mm","cmc":"4,1 µm"},{"name":"- 0,001 mm","range":"od 35 mm to 60 mm","cmc":"4,2 µm"},{"name":"- 0,001 mm","range":"od 50 mm to 150 mm","cmc":"4,7 µm"},{"name":"- 0,001 mm","range":"od 150 mm to 250 mm","cmc":"5,5 µm"},{"name":"- 0,001 mm","range":"od 250 mm to 500 mm","cmc":"8,1 µm"},{"name":"- 0,002 mm","range":"0 mm to 35 mm","cmc":"4,2 µm"},{"name":"- 0,002 mm","range":"od 35 mm to 60 mm","cmc":"4,3 µm"},{"name":"- 0,002 mm","range":"od 50 mm to 150 mm","cmc":"4,8 µm"},{"name":"- 0,002 mm","range":"od 150 mm to 250 mm","cmc":"5,6 µm"},{"name":"- 0,002 mm","range":"od 250 mm to 500 mm","cmc":"8,2 µm"},{"name":"- 0,005 mm","range":"0 mm to 35 mm","cmc":"5,0 µm"},{"name":"- 0,005 mm","range":"od 35 mm to 60 mm","cmc":"5,1 µm"},{"name":"- 0,005 mm","range":"od 50 mm to 150 mm","cmc":"5,5 mm"},{"name":"- 0,005 mm","range":"od 150 mm to 250 mm","cmc":"6,2 µm"},{"name":"- 0,005 mm","range":"od 250 mm to 500 mm","cmc":"8,6 µm"},{"name":"- 0,01 mm","range":"0 mm to 35 mm","cmc":"7,2 µm"},{"name":"- 0,01 mm","range":"od 35 mm to 60 mm","cmc":"7,2 µm"},{"name":"- 0,01 mm","range":"od 50 mm to 150 mm","cmc":"7,5 µm"},{"name":"- 0,01 mm","range":"od 150 mm to 250 mm","cmc":"8,0 µm"},{"name":"- 0,01 mm","range":"od 250 mm to 500 mm","cmc":"10,0 µm"},{"name":"- 0,02 mm","range":"0 mm to 35 mm","cmc":"13,5 µm"},{"name":"- 0,02 mm","range":"od 35 mm to 60 mm","cmc":"13,6 µm"},{"name":"- 0,02 mm","range":"od 50 mm to 150 mm","cmc":"13,7 µm"},{"name":"- 0,02 mm","range":"od 150 mm to 250 mm","cmc":"14,00 µm"},{"name":"- 0,02 mm","range":"od 250 mm to 500 mm","cmc":"15,2 µm"},{"name":"- 0,05 mm","range":"0 mm to 35 mm","cmc":"32,7µm"},{"name":"- 0,05 mm","range":"od 35 mm to 60 mm","cmc":"32,7 µm"},{"name":"- 0,05 mm","range":"od 50 mm to 150 mm","cmc":"32,8 µm"},{"name":"- 0,05 mm","range":"od 150 mm to 250 mm","cmc":"32,9 µm"},{"name":"- 0,05 mm","range":"od 250 mm to 500 mm","cmc":"33,5 µm"}],"reference_zh":"内部程序 IW-10-LW-AK-05","regulatory_area_zh":"长度","search_zh":"带数显指示表的内径指示表，分辨力： 校准 — 长度 内部程序；使用量块；在固定地点 (S) 长度 内部程序 使用量块 在固定地点 (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,05 mm - 0,05 mm - 0,05 mm - 0,05 mm - 0,05 mm 内部程序 IW-10-LW-AK-05","technique_zh":"内部程序；使用量块；在固定地点 (S)","techniques_zh":["内部程序","使用量块","在固定地点 (S)"],"test_object_zh":"带数显指示表的内径指示表，分辨力：","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- 0,001 mm","range":"0 mm to 35 mm","cmc":"4,1 µm"},{"name":"- 0,001 mm","range":"od 35 mm to 60 mm","cmc":"4,2 µm"},{"name":"- 0,001 mm","range":"od 50 mm to 150 mm","cmc":"4,7 µm"},{"name":"- 0,001 mm","range":"od 150 mm to 250 mm","cmc":"5,5 µm"},{"name":"- 0,001 mm","range":"od 250 mm to 500 mm","cmc":"8,1 µm"},{"name":"- 0,002 mm","range":"0 mm to 35 mm","cmc":"4,2 µm"},{"name":"- 0,002 mm","range":"od 35 mm to 60 mm","cmc":"4,3 µm"},{"name":"- 0,002 mm","range":"od 50 mm to 150 mm","cmc":"4,8 µm"},{"name":"- 0,002 mm","range":"od 150 mm to 250 mm","cmc":"5,6 µm"},{"name":"- 0,002 mm","range":"od 250 mm to 500 mm","cmc":"8,2 µm"},{"name":"- 0,005 mm","range":"0 mm to 35 mm","cmc":"5,0 µm"},{"name":"- 0,005 mm","range":"od 35 mm to 60 mm","cmc":"5,1 µm"},{"name":"- 0,005 mm","range":"od 50 mm to 150 mm","cmc":"5,5 mm"},{"name":"- 0,005 mm","range":"od 150 mm to 250 mm","cmc":"6,2 µm"},{"name":"- 0,005 mm","range":"od 250 mm to 500 mm","cmc":"8,6 µm"},{"name":"- 0,01 mm","range":"0 mm to 35 mm","cmc":"7,2 µm"},{"name":"- 0,01 mm","range":"od 35 mm to 60 mm","cmc":"7,2 µm"},{"name":"- 0,01 mm","range":"od 50 mm to 150 mm","cmc":"7,5 µm"},{"name":"- 0,01 mm","range":"od 150 mm to 250 mm","cmc":"8,0 µm"},{"name":"- 0,01 mm","range":"od 250 mm to 500 mm","cmc":"10,0 µm"},{"name":"- 0,02 mm","range":"0 mm to 35 mm","cmc":"13,5 µm"},{"name":"- 0,02 mm","range":"od 35 mm to 60 mm","cmc":"13,6 µm"},{"name":"- 0,02 mm","range":"od 50 mm to 150 mm","cmc":"13,7 µm"},{"name":"- 0,02 mm","range":"od 150 mm to 250 mm","cmc":"14,00 µm"},{"name":"- 0,02 mm","range":"od 250 mm to 500 mm","cmc":"15,2 µm"},{"name":"- 0,05 mm","range":"0 mm to 35 mm","cmc":"32,7µm"},{"name":"- 0,05 mm","range":"od 35 mm to 60 mm","cmc":"32,7 µm"},{"name":"- 0,05 mm","range":"od 50 mm to 150 mm","cmc":"32,8 µm"},{"name":"- 0,05 mm","range":"od 150 mm to 250 mm","cmc":"32,9 µm"},{"name":"- 0,05 mm","range":"od 250 mm to 500 mm","cmc":"33,5 µm"}],"reference_cs":"Vnitřní postup IW-10-LW-AK-05","regulatory_area_cs":"Délka","search_cs":"Dutinoměry s digitálním úchylkoměrem s rozlišením: Kalibrace — Délka Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí koncových měrek Ve stálé lokalitě (S) - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,001 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,002 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,005 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,01 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,02 mm - 0,05 mm - 0,05 mm - 0,05 mm - 0,05 mm - 0,05 mm Vnitřní postup IW-10-LW-AK-05","technique_cs":"Vnitřní postup; pomocí koncových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí koncových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Dutinoměry s digitálním úchylkoměrem s rozlišením:"},{"_id":"4d7079509176a9ba0fa06023","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Przymiary sztywne","test_object_en":"Rigid rules","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 750 mm","cmc":"(40,2 + 12,1 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 750 mm","cmc":"(40,2 + 12,1 · L) µm"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 750 mm CMC (40,2 + 12,1 · L) µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-06","norm_bases":["IW-9-LW-AK-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Przymiary sztywne Wzorcowanie — Długość\n0 mm do 750 mm CMC (40,2 + 12,1 · L) µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-06 Przymiary sztywne Wzorcowanie — Dlugosc\n0 mm do 750 mm CMC (40,2 + 12,1 · L) µm\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-06","search_en":"Rigid rules Calibration — Length Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Length Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) Internal procedure IW-9-LW-AK-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":63,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-06","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 750 mm","cmc":"(40,2 + 12,1 · L) µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-06","regulatory_area_de":"Länge","search_de":"Starre Maßstäbe Kalibrierung — Länge Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) Internes Verfahren IW-9-LW-AK-06","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Starre Maßstäbe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 750 mm","cmc":"(40,2 + 12,1 · L) µm"}],"reference_zh":"内部程序 IW-9-LW-AK-06","regulatory_area_zh":"长度","search_zh":"刚性量尺 校准 — 长度 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 长度 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) 内部程序 IW-9-LW-AK-06","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"刚性量尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 750 mm","cmc":"(40,2 + 12,1 · L) µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-06","regulatory_area_cs":"Délka","search_cs":"Tuhá délková měřidla Kalibrace — Délka Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) Vnitřní postup IW-9-LW-AK-06","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Tuhá délková měřidla"},{"_id":"efa79678567f9873faef7f3d","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Przymiary półsztywne","test_object_en":"Semi-rigid rules","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 750 mm","cmc":"(40,2 + 22,2 · L) µm"}],"parameters_en":[{"name":"","range":"0 mm to 750 mm","cmc":"(40,2 + 22,2 · L) µm"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 750 mm CMC (40,2 + 22,2 · L) µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-06","norm_bases":["IW-9-LW-AK-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":"L - wielkość mierzona (m)","note_en":"L - measured quantity (m)","search_text":"Przymiary półsztywne Wzorcowanie — Długość\n0 mm do 750 mm CMC (40,2 + 22,2 · L) µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-06 Przymiary polsztywne Wzorcowanie — Dlugosc\n0 mm do 750 mm CMC (40,2 + 22,2 · L) µm\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-06","search_en":"Semi-rigid rules Calibration — Length Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Length Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) Internal procedure IW-9-LW-AK-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":64,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-06","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 750 mm","cmc":"(40,2 + 22,2 · L) µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-06","regulatory_area_de":"Länge","search_de":"Halbstarre Maßstäbe Kalibrierung — Länge Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) Internes Verfahren IW-9-LW-AK-06","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Halbstarre Maßstäbe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 750 mm","cmc":"(40,2 + 22,2 · L) µm"}],"reference_zh":"内部程序 IW-9-LW-AK-06","regulatory_area_zh":"长度","search_zh":"半刚性量尺 校准 — 长度 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 长度 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) 内部程序 IW-9-LW-AK-06","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"半刚性量尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 750 mm","cmc":"(40,2 + 22,2 · L) µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-06","regulatory_area_cs":"Délka","search_cs":"Polotuhá délková měřidla Kalibrace — Délka Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) Vnitřní postup IW-9-LW-AK-06","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Polotuhá délková měřidla"},{"_id":"24cab923b1b23ae660c3bfd8","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Wzorce kreskowe lup pomiarowych","test_object_en":"Line scales of measuring magnifiers","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 20 mm","cmc":"3,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 20 mm","cmc":"3,6 µm"}],"technique":"Procedura wewnętrzna; pomiar przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; measurement using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","pomiar przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","measurement using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 20 mm CMC 3,6 µm\nProcedura wewnętrzna; pomiar przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-08","norm_bases":["IW-9-LW-AK-08"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wzorce kreskowe lup pomiarowych Wzorcowanie — Długość\n0 mm do 20 mm CMC 3,6 µm\nProcedura wewnętrzna; pomiar przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-08 Wzorce kreskowe lup pomiarowych Wzorcowanie — Dlugosc\n0 mm do 20 mm CMC 3,6 µm\nProcedura wewnetrzna; pomiar przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-08","search_en":"Line scales of measuring magnifiers Calibration — Length Internal procedure; measurement using the O-Inspect coordinate measuring machine; At permanent location (S) Length Internal procedure measurement using the O-Inspect coordinate measuring machine At permanent location (S) Internal procedure IW-9-LW-AK-08","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":65,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-08","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm to 20 mm","cmc":"3,6 µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-08","regulatory_area_de":"Länge","search_de":"Strichmaßstäbe von Messlupen Kalibrierung — Länge Internes Verfahren; Messung mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge Internes Verfahren Messung mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) Internes Verfahren IW-9-LW-AK-08","technique_de":"Internes Verfahren; Messung mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Strichmaßstäbe von Messlupen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm to 20 mm","cmc":"3,6 µm"}],"reference_zh":"内部程序 IW-9-LW-AK-08","regulatory_area_zh":"长度","search_zh":"测量放大镜线纹尺 校准 — 长度 内部程序；使用O-Inspect坐标测量机测量；在固定地点 (S) 长度 内部程序 使用O-Inspect坐标测量机测量 在固定地点 (S) 内部程序 IW-9-LW-AK-08","technique_zh":"内部程序；使用O-Inspect坐标测量机测量；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机测量","在固定地点 (S)"],"test_object_zh":"测量放大镜线纹尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm to 20 mm","cmc":"3,6 µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-08","regulatory_area_cs":"Délka","search_cs":"Čárková měřítka měřicích lup Kalibrace — Délka Vnitřní postup; měření pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka Vnitřní postup měření pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) Vnitřní postup IW-9-LW-AK-08","technique_cs":"Vnitřní postup; měření pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","měření pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Čárková měřítka měřicích lup"},{"_id":"27de768d9f525ccd3a92bf92","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Szczelinomierze klinowe","test_object_en":"Taper feeler gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 50 mm","cmc":"29,4 µm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"29,4 µm"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 50 mm CMC 29,4 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-12","norm_bases":["IW-9-LW-AK-12"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Szczelinomierze klinowe Wzorcowanie — Długość\n0 mm do 50 mm CMC 29,4 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-12 Szczelinomierze klinowe Wzorcowanie — Dlugosc\n0 mm do 50 mm CMC 29,4 µm\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-12","search_en":"Taper feeler gauges Calibration — Length Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Length Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) Internal procedure IW-9-LW-AK-12","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":66,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-12","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 50 mm","cmc":"29,4 µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-12","regulatory_area_de":"Länge","search_de":"Keilfühlerlehren Kalibrierung — Länge Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) Internes Verfahren IW-9-LW-AK-12","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Keilfühlerlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"29,4 µm"}],"reference_zh":"内部程序 IW-9-LW-AK-12","regulatory_area_zh":"长度","search_zh":"楔形塞尺 校准 — 长度 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 长度 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) 内部程序 IW-9-LW-AK-12","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"楔形塞尺","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 50 mm","cmc":"29,4 µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-12","regulatory_area_cs":"Délka","search_cs":"Klínové spároměry Kalibrace — Délka Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) Vnitřní postup IW-9-LW-AK-12","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Klínové spároměry"},{"_id":"2d9fb18a5eb87b03145ffc92","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Sprawdziany stożkowe do otworów","test_object_en":"Taper hole gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0 mm do 200 mm","cmc":"20,0 µm"}],"parameters_en":[{"name":"","range":"0 mm to 200 mm","cmc":"20,0 µm"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0 mm do 200 mm CMC 20,0 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-11","norm_bases":["IW-9-LW-AK-11"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany stożkowe do otworów Wzorcowanie — Długość\n0 mm do 200 mm CMC 20,0 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-11 Sprawdziany stozkowe do otworow Wzorcowanie — Dlugosc\n0 mm do 200 mm CMC 20,0 µm\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-11","search_en":"Taper hole gauges Calibration — Length Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Length Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) Internal procedure IW-9-LW-AK-11","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":67,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-11","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0 mm bis 200 mm","cmc":"20,0 µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-11","regulatory_area_de":"Länge","search_de":"Kegellehren für Bohrungen Kalibrierung — Länge Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) Internes Verfahren IW-9-LW-AK-11","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Kegellehren für Bohrungen","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0 mm 至 200 mm","cmc":"20,0 µm"}],"reference_zh":"内部程序 IW-9-LW-AK-11","regulatory_area_zh":"长度","search_zh":"孔用锥度量规 校准 — 长度 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 长度 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) 内部程序 IW-9-LW-AK-11","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"孔用锥度量规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0 mm do 200 mm","cmc":"20,0 µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-11","regulatory_area_cs":"Délka","search_cs":"Kuželové kalibry pro otvory Kalibrace — Délka Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) Vnitřní postup IW-9-LW-AK-11","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Kuželové kalibry pro otvory"},{"_id":"272bfe090bc0a24456e3f3b1","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Spoinomierze","test_object_en":"Weld gauges","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"- suwmiarkowe","range":"0 mm do 50 mm","cmc":"16,7 µm"},{"name":"- specjalne","range":"0 mm do 60 mm","cmc":"16,7 µm"}],"parameters_en":[{"name":"- vernier type","range":"0 mm to 50 mm","cmc":"16,7 µm"},{"name":"- special","range":"0 mm to 60 mm","cmc":"16,7 µm"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n- suwmiarkowe 0 mm do 50 mm CMC 16,7 µm\n- specjalne 0 mm do 60 mm CMC 16,7 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-09 IW-9-LW-AK-10","norm_bases":["IW-9-LW-AK-09","IW-9-LW-AK-10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Spoinomierze Wzorcowanie — Długość\nZakres:\n- suwmiarkowe 0 mm do 50 mm CMC 16,7 µm\n- specjalne 0 mm do 60 mm CMC 16,7 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-09 IW-9-LW-AK-10 Spoinomierze Wzorcowanie — Dlugosc\nZakres:\n- suwmiarkowe 0 mm do 50 mm CMC 16,7 µm\n- specjalne 0 mm do 60 mm CMC 16,7 µm\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-09 IW-9-LW-AK-10","search_en":"Weld gauges Calibration — Length Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Length Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) - vernier type - special Internal procedure IW-9-LW-AK-09 IW-9-LW-AK-10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":68,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-09 IW-9-LW-AK-10","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"- Messschieberbauart","range":"0 mm bis 50 mm","cmc":"16,7 µm"},{"name":"- Sonderausführungen","range":"0 mm to 60 mm","cmc":"16,7 µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-09 IW-9-LW-AK-10","regulatory_area_de":"Länge","search_de":"Schweißnahtlehren Kalibrierung — Länge Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) - Messschieberbauart - Sonderausführungen Internes Verfahren IW-9-LW-AK-09 IW-9-LW-AK-10","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Schweißnahtlehren","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"- 游标式","range":"0 mm 至 50 mm","cmc":"16,7 µm"},{"name":"- 专用","range":"0 mm to 60 mm","cmc":"16,7 µm"}],"reference_zh":"内部程序 IW-9-LW-AK-09 IW-9-LW-AK-10","regulatory_area_zh":"长度","search_zh":"焊缝量规 校准 — 长度 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 长度 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) - 游标式 - 专用 内部程序 IW-9-LW-AK-09 IW-9-LW-AK-10","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"焊缝量规","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"- posuvné","range":"0 mm do 50 mm","cmc":"16,7 µm"},{"name":"- speciální","range":"0 mm to 60 mm","cmc":"16,7 µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-09 IW-9-LW-AK-10","regulatory_area_cs":"Délka","search_cs":"Svarové měrky Kalibrace — Délka Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) - posuvné - speciální Vnitřní postup IW-9-LW-AK-09 IW-9-LW-AK-10","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Svarové měrky"},{"_id":"603a227b75fe634825b17145","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Sprawdziany specjalne","test_object_en":"Special gauges","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 360°","cmc":"48’’"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"48’’"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 360° CMC 48’’\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-01","norm_bases":["IW-9-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany specjalne Wzorcowanie — Kąt\n0° do 360° CMC 48’’\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-01 Sprawdziany specjalne Wzorcowanie — Kat\n0° do 360° CMC 48’’\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-01","search_en":"Special gauges Calibration — Angle Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Angle Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) Internal procedure IW-9-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":69,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-01","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° bis 360°","cmc":"48’’"}],"reference_de":"Internes Verfahren IW-9-LW-AK-01","regulatory_area_de":"Winkel","search_de":"Sonderlehren Kalibrierung — Winkel Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Winkel Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) Internes Verfahren IW-9-LW-AK-01","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Sonderlehren","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"48’’"}],"reference_zh":"内部程序 IW-9-LW-AK-01","regulatory_area_zh":"角度","search_zh":"专用量规 校准 — 角度 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 角度 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) 内部程序 IW-9-LW-AK-01","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"专用量规","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° do 360°","cmc":"48’’"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-01","regulatory_area_cs":"Úhel","search_cs":"Speciální kalibry Kalibrace — Úhel Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Úhel Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) Vnitřní postup IW-9-LW-AK-01","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Speciální kalibry"},{"_id":"5084cc910b8520cbd30fa46a","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Kątomierze uniwersalne analogowe","test_object_en":"Analogue universal bevel protractors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"4x90°","cmc":"2,8’"}],"parameters_en":[{"name":"","range":"4x90°","cmc":"2,8’"}],"technique":"Procedura wewnętrzna; przy użyciu płytek kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu płytek kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n4x90° CMC 2,8’\nProcedura wewnętrzna; przy użyciu płytek kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-11-LW-AK-03","norm_bases":["IW-11-LW-AK-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątomierze uniwersalne analogowe Wzorcowanie — Kąt\n4x90° CMC 2,8’\nProcedura wewnętrzna; przy użyciu płytek kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-11-LW-AK-03 Katomierze uniwersalne analogowe Wzorcowanie — Kat\n4x90° CMC 2,8’\nProcedura wewnetrzna; przy uzyciu plytek katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-11-LW-AK-03","search_en":"Analogue universal bevel protractors Calibration — Angle Internal procedure; using angle gauge blocks; At permanent location (S) Angle Internal procedure using angle gauge blocks At permanent location (S) Internal procedure IW-11-LW-AK-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":70,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-11-LW-AK-03","methodology_de":"Kalibrierung — Winkel","reference_de":"Internes Verfahren IW-11-LW-AK-03","regulatory_area_de":"Winkel","search_de":"Analoge Universalwinkelmesser Kalibrierung — Winkel Internes Verfahren; mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren mit Winkelendmaßen Am festen Standort (S) Internes Verfahren IW-11-LW-AK-03","technique_de":"Internes Verfahren; mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Analoge Universalwinkelmesser","methodology_zh":"校准 — 角度","reference_zh":"内部程序 IW-11-LW-AK-03","regulatory_area_zh":"角度","search_zh":"模拟万能角度尺 校准 — 角度 内部程序；使用角度块；在固定地点 (S) 角度 内部程序 使用角度块 在固定地点 (S) 内部程序 IW-11-LW-AK-03","technique_zh":"内部程序；使用角度块；在固定地点 (S)","techniques_zh":["内部程序","使用角度块","在固定地点 (S)"],"test_object_zh":"模拟万能角度尺","methodology_cs":"Kalibrace — Úhel","reference_cs":"Vnitřní postup IW-11-LW-AK-03","regulatory_area_cs":"Úhel","search_cs":"Analogové univerzální úhloměry Kalibrace — Úhel Vnitřní postup; pomocí úhlových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup pomocí úhlových měrek Ve stálé lokalitě (S) Vnitřní postup IW-11-LW-AK-03","technique_cs":"Vnitřní postup; pomocí úhlových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí úhlových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové univerzální úhloměry"},{"_id":"3c4cce64d6d071ad65924e1b","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Kątomierze uniwersalne cyfrowe","test_object_en":"Digital universal bevel protractors","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 360°","cmc":"2,5’"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"2,5’"}],"technique":"Procedura wewnętrzna; przy użyciu płytek kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu płytek kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 360° CMC 2,5’\nProcedura wewnętrzna; przy użyciu płytek kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-11-LW-AK-03","norm_bases":["IW-11-LW-AK-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątomierze uniwersalne cyfrowe Wzorcowanie — Kąt\n0° do 360° CMC 2,5’\nProcedura wewnętrzna; przy użyciu płytek kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-11-LW-AK-03 Katomierze uniwersalne cyfrowe Wzorcowanie — Kat\n0° do 360° CMC 2,5’\nProcedura wewnetrzna; przy uzyciu plytek katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-11-LW-AK-03","search_en":"Digital universal bevel protractors Calibration — Angle Internal procedure; using angle gauge blocks; At permanent location (S) Angle Internal procedure using angle gauge blocks At permanent location (S) Internal procedure IW-11-LW-AK-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":71,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-11-LW-AK-03","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° bis 360°","cmc":"2,5’"}],"reference_de":"Internes Verfahren IW-11-LW-AK-03","regulatory_area_de":"Winkel","search_de":"Digitale Universalwinkelmesser Kalibrierung — Winkel Internes Verfahren; mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren mit Winkelendmaßen Am festen Standort (S) Internes Verfahren IW-11-LW-AK-03","technique_de":"Internes Verfahren; mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Digitale Universalwinkelmesser","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"2,5’"}],"reference_zh":"内部程序 IW-11-LW-AK-03","regulatory_area_zh":"角度","search_zh":"数显万能角度尺 校准 — 角度 内部程序；使用角度块；在固定地点 (S) 角度 内部程序 使用角度块 在固定地点 (S) 内部程序 IW-11-LW-AK-03","technique_zh":"内部程序；使用角度块；在固定地点 (S)","techniques_zh":["内部程序","使用角度块","在固定地点 (S)"],"test_object_zh":"数显万能角度尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° do 360°","cmc":"2,5’"}],"reference_cs":"Vnitřní postup IW-11-LW-AK-03","regulatory_area_cs":"Úhel","search_cs":"Digitální univerzální úhloměry Kalibrace — Úhel Vnitřní postup; pomocí úhlových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup pomocí úhlových měrek Ve stálé lokalitě (S) Vnitřní postup IW-11-LW-AK-03","technique_cs":"Vnitřní postup; pomocí úhlových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí úhlových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální univerzální úhloměry"},{"_id":"5f7e79c639d2d05ab1c7ad97","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Poziomnice cyfrowe","test_object_en":"Digital levels","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"4x90°","cmc":"0,04°"}],"parameters_en":[{"name":"","range":"4x90°","cmc":"0,04°"}],"technique":"Procedura wewnętrzna; przy użyciu płytek kątowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; using angle gauge blocks; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu płytek kątowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using angle gauge blocks","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n4x90° CMC 0,04°\nProcedura wewnętrzna; przy użyciu płytek kątowych; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-11-LW-AK-04","norm_bases":["IW-11-LW-AK-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Poziomnice cyfrowe Wzorcowanie — Kąt\n4x90° CMC 0,04°\nProcedura wewnętrzna; przy użyciu płytek kątowych; W stałej lokalizacji (S) Procedura wewnętrzna IW-11-LW-AK-04 Poziomnice cyfrowe Wzorcowanie — Kat\n4x90° CMC 0,04°\nProcedura wewnetrzna; przy uzyciu plytek katowych; W stalej lokalizacji (S) Procedura wewnetrzna IW-11-LW-AK-04","search_en":"Digital levels Calibration — Angle Internal procedure; using angle gauge blocks; At permanent location (S) Angle Internal procedure using angle gauge blocks At permanent location (S) Internal procedure IW-11-LW-AK-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":72,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-11-LW-AK-04","methodology_de":"Kalibrierung — Winkel","reference_de":"Internes Verfahren IW-11-LW-AK-04","regulatory_area_de":"Winkel","search_de":"Digitale Wasserwaagen Kalibrierung — Winkel Internes Verfahren; mit Winkelendmaßen; Am festen Standort (S) Winkel Internes Verfahren mit Winkelendmaßen Am festen Standort (S) Internes Verfahren IW-11-LW-AK-04","technique_de":"Internes Verfahren; mit Winkelendmaßen; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit Winkelendmaßen","Am festen Standort (S)"],"test_object_de":"Digitale Wasserwaagen","methodology_zh":"校准 — 角度","reference_zh":"内部程序 IW-11-LW-AK-04","regulatory_area_zh":"角度","search_zh":"数显水平仪 校准 — 角度 内部程序；使用角度块；在固定地点 (S) 角度 内部程序 使用角度块 在固定地点 (S) 内部程序 IW-11-LW-AK-04","technique_zh":"内部程序；使用角度块；在固定地点 (S)","techniques_zh":["内部程序","使用角度块","在固定地点 (S)"],"test_object_zh":"数显水平仪","methodology_cs":"Kalibrace — Úhel","reference_cs":"Vnitřní postup IW-11-LW-AK-04","regulatory_area_cs":"Úhel","search_cs":"Digitální libely Kalibrace — Úhel Vnitřní postup; pomocí úhlových měrek; Ve stálé lokalitě (S) Úhel Vnitřní postup pomocí úhlových měrek Ve stálé lokalitě (S) Vnitřní postup IW-11-LW-AK-04","technique_cs":"Vnitřní postup; pomocí úhlových měrek; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí úhlových měrek","Ve stálé lokalitě (S)"],"test_object_cs":"Digitální libely"},{"_id":"e8dd35f39e5c0eec4376ce4b","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Spoinomierze (pomiar kąta ukosowania)","test_object_en":"Weld gauges (bevel angle measurement)","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"- suwmiarkowe","range":"60° do 90°","cmc":"5’ 11’’"},{"name":"- specjalne","range":"do 160°","cmc":"5’ 11’’"}],"parameters_en":[{"name":"- vernier type","range":"60° to 90°","cmc":"5’ 11’’"},{"name":"- special","range":"up to 160°","cmc":"5’ 11’’"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\nZakres:\n- suwmiarkowe 60° do 90° CMC 5’ 11’’\n- specjalne do 160° CMC 5’ 11’’\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-09 IW-9-LW-AK-10","norm_bases":["IW-9-LW-AK-09","IW-9-LW-AK-10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Spoinomierze (pomiar kąta ukosowania) Wzorcowanie — Kąt\nZakres:\n- suwmiarkowe 60° do 90° CMC 5’ 11’’\n- specjalne do 160° CMC 5’ 11’’\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-09 IW-9-LW-AK-10 Spoinomierze (pomiar kata ukosowania) Wzorcowanie — Kat\nZakres:\n- suwmiarkowe 60° do 90° CMC 5’ 11’’\n- specjalne do 160° CMC 5’ 11’’\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-09 IW-9-LW-AK-10","search_en":"Weld gauges (bevel angle measurement) Calibration — Angle Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Angle Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) - vernier type - special Internal procedure IW-9-LW-AK-09 IW-9-LW-AK-10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":73,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-09 IW-9-LW-AK-10","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"- Messschieberbauart","range":"60° to 90°","cmc":"5’ 11’’"},{"name":"- Sonderausführungen","range":"bis 160°","cmc":"5’ 11’’"}],"reference_de":"Internes Verfahren IW-9-LW-AK-09 IW-9-LW-AK-10","regulatory_area_de":"Winkel","search_de":"Schweißnahtlehren (Messung des Fugenflankenwinkels) Kalibrierung — Winkel Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Winkel Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) - Messschieberbauart - Sonderausführungen Internes Verfahren IW-9-LW-AK-09 IW-9-LW-AK-10","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Schweißnahtlehren (Messung des Fugenflankenwinkels)","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"- 游标式","range":"60° to 90°","cmc":"5’ 11’’"},{"name":"- 专用","range":"至 160°","cmc":"5’ 11’’"}],"reference_zh":"内部程序 IW-9-LW-AK-09 IW-9-LW-AK-10","regulatory_area_zh":"角度","search_zh":"焊缝规（坡口角度测量） 校准 — 角度 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 角度 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) - 游标式 - 专用 内部程序 IW-9-LW-AK-09 IW-9-LW-AK-10","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"焊缝规（坡口角度测量）","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"- posuvné","range":"60° to 90°","cmc":"5’ 11’’"},{"name":"- speciální","range":"do 160°","cmc":"5’ 11’’"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-09 IW-9-LW-AK-10","regulatory_area_cs":"Úhel","search_cs":"Měrky svarů (měření úhlu úkosu) Kalibrace — Úhel Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Úhel Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) - posuvné - speciální Vnitřní postup IW-9-LW-AK-09 IW-9-LW-AK-10","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Měrky svarů (měření úhlu úkosu)"},{"_id":"3d3fc2a637a0a8e3beaae76b","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Kątowniki dwuramienne specjalne","test_object_en":"Special try squares","methodology":"Wzorcowanie — Kąt","methodology_en":"Calibration — Angle","parameters":[{"name":"","range":"0° do 360°","cmc":"48’’"}],"parameters_en":[{"name":"","range":"0° to 360°","cmc":"48’’"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Kąt\n0° do 360° CMC 48’’\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-05","norm_bases":["IW-9-LW-AK-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Kąt","regulatory_area_en":"Angle","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kątowniki dwuramienne specjalne Wzorcowanie — Kąt\n0° do 360° CMC 48’’\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-05 Katowniki dwuramienne specjalne Wzorcowanie — Kat\n0° do 360° CMC 48’’\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-05","search_en":"Special try squares Calibration — Angle Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Angle Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) Internal procedure IW-9-LW-AK-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":74,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-05","methodology_de":"Kalibrierung — Winkel","parameters_de":[{"name":"","range":"0° bis 360°","cmc":"48’’"}],"reference_de":"Internes Verfahren IW-9-LW-AK-05","regulatory_area_de":"Winkel","search_de":"Spezial-Flachwinkel Kalibrierung — Winkel Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Winkel Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) Internes Verfahren IW-9-LW-AK-05","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Spezial-Flachwinkel","methodology_zh":"校准 — 角度","parameters_zh":[{"name":"","range":"0° 至 360°","cmc":"48’’"}],"reference_zh":"内部程序 IW-9-LW-AK-05","regulatory_area_zh":"角度","search_zh":"专用宽座直角尺 校准 — 角度 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 角度 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) 内部程序 IW-9-LW-AK-05","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"专用宽座直角尺","methodology_cs":"Kalibrace — Úhel","parameters_cs":[{"name":"","range":"0° do 360°","cmc":"48’’"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-05","regulatory_area_cs":"Úhel","search_cs":"Speciální dvouramenné úhelníky Kalibrace — Úhel Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Úhel Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) Vnitřní postup IW-9-LW-AK-05","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Speciální dvouramenné úhelníky"},{"_id":"2b9b0252312365a1450f98d1","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Płyty pomiarowe","test_object_en":"Surface plates","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"250 mm","cmc":"1,2 µm"},{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"400 mm","cmc":"1,7 µm"},{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"500 mm","cmc":"1,8 µm"},{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"630 mm","cmc":"2,8 µm"},{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"800 mm","cmc":"2,7 µm"},{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"1000 mm","cmc":"3,0 µm"},{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"1200 mm","cmc":"3,3 µm"},{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"1600 mm","cmc":"3,8 µm"},{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"2000 mm","cmc":"4,3 µm"},{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"2500 mm","cmc":"4,8 µm"},{"name":"- odchylenie od płaskości; długość dłuższego boku","range":"3000 mm","cmc":"5,3 µm"}],"parameters_en":[{"name":"- flatness deviation; length of the longer side","range":"250 mm","cmc":"1,2 µm"},{"name":"- flatness deviation; length of the longer side","range":"400 mm","cmc":"1,7 µm"},{"name":"- flatness deviation; length of the longer side","range":"500 mm","cmc":"1,8 µm"},{"name":"- flatness deviation; length of the longer side","range":"630 mm","cmc":"2,8 µm"},{"name":"- flatness deviation; length of the longer side","range":"800 mm","cmc":"2,7 µm"},{"name":"- flatness deviation; length of the longer side","range":"1000 mm","cmc":"3,0 µm"},{"name":"- flatness deviation; length of the longer side","range":"1200 mm","cmc":"3,3 µm"},{"name":"- flatness deviation; length of the longer side","range":"1600 mm","cmc":"3,8 µm"},{"name":"- flatness deviation; length of the longer side","range":"2000 mm","cmc":"4,3 µm"},{"name":"- flatness deviation; length of the longer side","range":"2500 mm","cmc":"4,8 µm"},{"name":"- flatness deviation; length of the longer side","range":"3000 mm","cmc":"5,3 µm"}],"technique":"Procedura wewnętrzna; przy użyciu poziomnic różnicowych Talyvel 6; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; using Talyvel 6 differential levels; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","przy użyciu poziomnic różnicowych Talyvel 6","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","using Talyvel 6 differential levels","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\nZakres:\n- odchylenie od płaskości; długość dłuższego boku 250 mm CMC 1,2 µm\n- odchylenie od płaskości; długość dłuższego boku 400 mm CMC 1,7 µm\n- odchylenie od płaskości; długość dłuższego boku 500 mm CMC 1,8 µm\n- odchylenie od płaskości; długość dłuższego boku 630 mm CMC 2,8 µm\n- odchylenie od płaskości; długość dłuższego boku 800 mm CMC 2,7 µm\n- odchylenie od płaskości; długość dłuższego boku 1000 mm CMC 3,0 µm\n- odchylenie od płaskości; długość dłuższego boku 1200 mm CMC 3,3 µm\n- odchylenie od płaskości; długość dłuższego boku 1600 mm CMC 3,8 µm\n- odchylenie od płaskości; długość dłuższego boku 2000 mm CMC 4,3 µm\n- odchylenie od płaskości; długość dłuższego boku 2500 mm CMC 4,8 µm\n- odchylenie od płaskości; długość dłuższego boku 3000 mm CMC 5,3 µm\nProcedura wewnętrzna; przy użyciu poziomnic różnicowych Talyvel 6; W stałej lokalizacji (S) i poza nią (P)","reference":"Procedura wewnętrzna IW-4-LW-AK-01","norm_bases":["IW-4-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Płyty pomiarowe Wzorcowanie — Długość (geometria powierzchni)\nZakres:\n- odchylenie od płaskości; długość dłuższego boku 250 mm CMC 1,2 µm\n- odchylenie od płaskości; długość dłuższego boku 400 mm CMC 1,7 µm\n- odchylenie od płaskości; długość dłuższego boku 500 mm CMC 1,8 µm\n- odchylenie od płaskości; długość dłuższego boku 630 mm CMC 2,8 µm\n- odchylenie od płaskości; długość dłuższego boku 800 mm CMC 2,7 µm\n- odchylenie od płaskości; długość dłuższego boku 1000 mm CMC 3,0 µm\n- odchylenie od płaskości; długość dłuższego boku 1200 mm CMC 3,3 µm\n- odchylenie od płaskości; długość dłuższego boku 1600 mm CMC 3,8 µm\n- odchylenie od płaskości; długość dłuższego boku 2000 mm CMC 4,3 µm\n- odchylenie od płaskości; długość dłuższego boku 2500 mm CMC 4,8 µm\n- odchylenie od płaskości; długość dłuższego boku 3000 mm CMC 5,3 µm\nProcedura wewnętrzna; przy użyciu poziomnic różnicowych Talyvel 6; W stałej lokalizacji (S) i poza nią (P) Procedura wewnętrzna IW-4-LW-AK-01 Plyty pomiarowe Wzorcowanie — Dlugosc (geometria powierzchni)\nZakres:\n- odchylenie od plaskosci; dlugosc dluzszego boku 250 mm CMC 1,2 µm\n- odchylenie od plaskosci; dlugosc dluzszego boku 400 mm CMC 1,7 µm\n- odchylenie od plaskosci; dlugosc dluzszego boku 500 mm CMC 1,8 µm\n- odchylenie od plaskosci; dlugosc dluzszego boku 630 mm CMC 2,8 µm\n- odchylenie od plaskosci; dlugosc dluzszego boku 800 mm CMC 2,7 µm\n- odchylenie od plaskosci; dlugosc dluzszego boku 1000 mm CMC 3,0 µm\n- odchylenie od plaskosci; dlugosc dluzszego boku 1200 mm CMC 3,3 µm\n- odchylenie od plaskosci; dlugosc dluzszego boku 1600 mm CMC 3,8 µm\n- odchylenie od plaskosci; dlugosc dluzszego boku 2000 mm CMC 4,3 µm\n- odchylenie od plaskosci; dlugosc dluzszego boku 2500 mm CMC 4,8 µm\n- odchylenie od plaskosci; dlugosc dluzszego boku 3000 mm CMC 5,3 µm\nProcedura wewnetrzna; przy uzyciu poziomnic roznicowych Talyvel 6; W stalej lokalizacji (S) i poza nia (P) Procedura wewnetrzna IW-4-LW-AK-01","search_en":"Surface plates Calibration — Length (surface geometry) Internal procedure; using Talyvel 6 differential levels; At permanent location (S) and outside of it (P) Length (surface geometry) Internal procedure using Talyvel 6 differential levels At permanent location (S) and outside of it (P) - flatness deviation; length of the longer side - flatness deviation; length of the longer side - flatness deviation; length of the longer side - flatness deviation; length of the longer side - flatness deviation; length of the longer side - flatness deviation; length of the longer side - flatness deviation; length of the longer side - flatness deviation; length of the longer side - flatness deviation; length of the longer side - flatness deviation; length of the longer side - flatness deviation; length of the longer side Internal procedure IW-4-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":75,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-4-LW-AK-01","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","parameters_de":[{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"250 mm","cmc":"1,2 µm"},{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"400 mm","cmc":"1,7 µm"},{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"500 mm","cmc":"1,8 µm"},{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"630 mm","cmc":"2,8 µm"},{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"800 mm","cmc":"2,7 µm"},{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"1000 mm","cmc":"3,0 µm"},{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"1200 mm","cmc":"3,3 µm"},{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"1600 mm","cmc":"3,8 µm"},{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"2000 mm","cmc":"4,3 µm"},{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"2500 mm","cmc":"4,8 µm"},{"name":"- Ebenheitsabweichung; Länge der längeren Seite","range":"3000 mm","cmc":"5,3 µm"}],"reference_de":"Internes Verfahren IW-4-LW-AK-01","regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Messplatten Kalibrierung — Länge (Oberflächengeometrie) Internes Verfahren; mit Differenzlibellen Talyvel 6; Am festen Standort (S) und außerhalb (P) Länge (Oberflächengeometrie) Internes Verfahren mit Differenzlibellen Talyvel 6 Am festen Standort (S) und außerhalb (P) - Ebenheitsabweichung; Länge der längeren Seite - Ebenheitsabweichung; Länge der längeren Seite - Ebenheitsabweichung; Länge der längeren Seite - Ebenheitsabweichung; Länge der längeren Seite - Ebenheitsabweichung; Länge der längeren Seite - Ebenheitsabweichung; Länge der längeren Seite - Ebenheitsabweichung; Länge der längeren Seite - Ebenheitsabweichung; Länge der längeren Seite - Ebenheitsabweichung; Länge der längeren Seite - Ebenheitsabweichung; Länge der längeren Seite - Ebenheitsabweichung; Länge der längeren Seite Internes Verfahren IW-4-LW-AK-01","technique_de":"Internes Verfahren; mit Differenzlibellen Talyvel 6; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","mit Differenzlibellen Talyvel 6","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Messplatten","methodology_zh":"校准 — 长度（表面几何）","parameters_zh":[{"name":"- 平面度偏差；长边长度","range":"250 mm","cmc":"1,2 µm"},{"name":"- 平面度偏差；长边长度","range":"400 mm","cmc":"1,7 µm"},{"name":"- 平面度偏差；长边长度","range":"500 mm","cmc":"1,8 µm"},{"name":"- 平面度偏差；长边长度","range":"630 mm","cmc":"2,8 µm"},{"name":"- 平面度偏差；长边长度","range":"800 mm","cmc":"2,7 µm"},{"name":"- 平面度偏差；长边长度","range":"1000 mm","cmc":"3,0 µm"},{"name":"- 平面度偏差；长边长度","range":"1200 mm","cmc":"3,3 µm"},{"name":"- 平面度偏差；长边长度","range":"1600 mm","cmc":"3,8 µm"},{"name":"- 平面度偏差；长边长度","range":"2000 mm","cmc":"4,3 µm"},{"name":"- 平面度偏差；长边长度","range":"2500 mm","cmc":"4,8 µm"},{"name":"- 平面度偏差；长边长度","range":"3000 mm","cmc":"5,3 µm"}],"reference_zh":"内部程序 IW-4-LW-AK-01","regulatory_area_zh":"长度（表面几何）","search_zh":"测量平板 校准 — 长度（表面几何） 内部程序；使用Talyvel 6差动水平仪；在固定地点 (S) 及固定地点以外 (P) 长度（表面几何） 内部程序 使用Talyvel 6差动水平仪 在固定地点 (S) 及固定地点以外 (P) - 平面度偏差；长边长度 - 平面度偏差；长边长度 - 平面度偏差；长边长度 - 平面度偏差；长边长度 - 平面度偏差；长边长度 - 平面度偏差；长边长度 - 平面度偏差；长边长度 - 平面度偏差；长边长度 - 平面度偏差；长边长度 - 平面度偏差；长边长度 - 平面度偏差；长边长度 内部程序 IW-4-LW-AK-01","technique_zh":"内部程序；使用Talyvel 6差动水平仪；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","使用Talyvel 6差动水平仪","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"测量平板","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","parameters_cs":[{"name":"- odchylka rovinnosti; délka delší strany","range":"250 mm","cmc":"1,2 µm"},{"name":"- odchylka rovinnosti; délka delší strany","range":"400 mm","cmc":"1,7 µm"},{"name":"- odchylka rovinnosti; délka delší strany","range":"500 mm","cmc":"1,8 µm"},{"name":"- odchylka rovinnosti; délka delší strany","range":"630 mm","cmc":"2,8 µm"},{"name":"- odchylka rovinnosti; délka delší strany","range":"800 mm","cmc":"2,7 µm"},{"name":"- odchylka rovinnosti; délka delší strany","range":"1000 mm","cmc":"3,0 µm"},{"name":"- odchylka rovinnosti; délka delší strany","range":"1200 mm","cmc":"3,3 µm"},{"name":"- odchylka rovinnosti; délka delší strany","range":"1600 mm","cmc":"3,8 µm"},{"name":"- odchylka rovinnosti; délka delší strany","range":"2000 mm","cmc":"4,3 µm"},{"name":"- odchylka rovinnosti; délka delší strany","range":"2500 mm","cmc":"4,8 µm"},{"name":"- odchylka rovinnosti; délka delší strany","range":"3000 mm","cmc":"5,3 µm"}],"reference_cs":"Vnitřní postup IW-4-LW-AK-01","regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Příměrné desky Kalibrace — Délka (geometrie povrchu) Vnitřní postup; pomocí diferenčních libel Talyvel 6; V trvalé lokalitě (S) i mimo ni (P) Délka (geometrie povrchu) Vnitřní postup pomocí diferenčních libel Talyvel 6 V trvalé lokalitě (S) i mimo ni (P) - odchylka rovinnosti; délka delší strany - odchylka rovinnosti; délka delší strany - odchylka rovinnosti; délka delší strany - odchylka rovinnosti; délka delší strany - odchylka rovinnosti; délka delší strany - odchylka rovinnosti; délka delší strany - odchylka rovinnosti; délka delší strany - odchylka rovinnosti; délka delší strany - odchylka rovinnosti; délka delší strany - odchylka rovinnosti; délka delší strany - odchylka rovinnosti; délka delší strany Vnitřní postup IW-4-LW-AK-01","technique_cs":"Vnitřní postup; pomocí diferenčních libel Talyvel 6; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","pomocí diferenčních libel Talyvel 6","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Příměrné desky"},{"_id":"8ea9741ecd8e92b7787acd1e","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Liniały krawędziowe","test_object_en":"Straight edges","methodology":"Wzorcowanie — Długość (geometria powierzchni)","methodology_en":"Calibration — Length (surface geometry)","parameters":[{"name":"","range":"0 mm do 750 mm","cmc":"2,6 µm"}],"parameters_en":[{"name":"","range":"0 mm to 750 mm","cmc":"2,6 µm"}],"technique":"Procedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (geometria powierzchni)\n0 mm do 750 mm CMC 2,6 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-07","norm_bases":["IW-9-LW-AK-07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (geometria powierzchni)","regulatory_area_en":"Length (surface geometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Liniały krawędziowe Wzorcowanie — Długość (geometria powierzchni)\n0 mm do 750 mm CMC 2,6 µm\nProcedura wewnętrzna; przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-07 Linialy krawedziowe Wzorcowanie — Dlugosc (geometria powierzchni)\n0 mm do 750 mm CMC 2,6 µm\nProcedura wewnetrzna; przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-07","search_en":"Straight edges Calibration — Length (surface geometry) Internal procedure; using the O-Inspect coordinate measuring machine; At permanent location (S) Length (surface geometry) Internal procedure using the O-Inspect coordinate measuring machine At permanent location (S) Internal procedure IW-9-LW-AK-07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":76,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-07","methodology_de":"Kalibrierung — Länge (Oberflächengeometrie)","parameters_de":[{"name":"","range":"0 mm to 750 mm","cmc":"2,6 µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-07","regulatory_area_de":"Länge (Oberflächengeometrie)","search_de":"Haarlineale Kalibrierung — Länge (Oberflächengeometrie) Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge (Oberflächengeometrie) Internes Verfahren mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) Internes Verfahren IW-9-LW-AK-07","technique_de":"Internes Verfahren; mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Haarlineale","methodology_zh":"校准 — 长度（表面几何）","parameters_zh":[{"name":"","range":"0 mm to 750 mm","cmc":"2,6 µm"}],"reference_zh":"内部程序 IW-9-LW-AK-07","regulatory_area_zh":"长度（表面几何）","search_zh":"刀口尺 校准 — 长度（表面几何） 内部程序；使用O-Inspect坐标测量机；在固定地点 (S) 长度（表面几何） 内部程序 使用O-Inspect坐标测量机 在固定地点 (S) 内部程序 IW-9-LW-AK-07","technique_zh":"内部程序；使用O-Inspect坐标测量机；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机","在固定地点 (S)"],"test_object_zh":"刀口尺","methodology_cs":"Kalibrace — Délka (geometrie povrchu)","parameters_cs":[{"name":"","range":"0 mm to 750 mm","cmc":"2,6 µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-07","regulatory_area_cs":"Délka (geometrie povrchu)","search_cs":"Nožová pravítka Kalibrace — Délka (geometrie povrchu) Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka (geometrie povrchu) Vnitřní postup pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) Vnitřní postup IW-9-LW-AK-07","technique_cs":"Vnitřní postup; pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Nožová pravítka"},{"_id":"7e864729f81b67bd1e1844fc","lab_id":"6afa3b998989a133b76445c5","country":"PL","accr_number":"AP 154","accr_body":"PCA","test_object":"Sprawdziany specjalne","test_object_en":"Special gauges","methodology":"Wzorcowanie — Długość (pomiary współrzędnościowe)","methodology_en":"Calibration — Length (coordinate measurements)","parameters":[{"name":"- długość","range":"0 mm do 600 mm","cmc":"4,2 µm"},{"name":"- szerokość","range":"0 mm do 400 mm","cmc":"4,2 µm"},{"name":"- średnica","range":"0 mm do 250 mm","cmc":"4,2 µm"},{"name":"- odchyłka kształtu","range":"0 mm do 1 mm","cmc":"3,0 µm"},{"name":"- odchyłki położenia","range":"0 mm do 600 mm","cmc":"4,1 µm"}],"parameters_en":[{"name":"- length","range":"0 mm to 600 mm","cmc":"4,2 µm"},{"name":"- width","range":"0 mm to 400 mm","cmc":"4,2 µm"},{"name":"- diameter","range":"0 mm to 250 mm","cmc":"4,2 µm"},{"name":"- form deviation","range":"0 mm to 1 mm","cmc":"3,0 µm"},{"name":"- location deviations","range":"0 mm to 600 mm","cmc":"4,1 µm"}],"technique":"Procedura wewnętrzna; pomiar przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","technique_en":"Internal procedure; measurement using the O-Inspect coordinate measuring machine; At permanent location (S)","techniques":["Procedura wewnętrzna","pomiar przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","measurement using the O-Inspect coordinate measuring machine","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość (pomiary współrzędnościowe)\nZakres:\n- długość 0 mm do 600 mm CMC 4,2 µm\n- szerokość 0 mm do 400 mm CMC 4,2 µm\n- średnica 0 mm do 250 mm CMC 4,2 µm\n- odchyłka kształtu 0 mm do 1 mm CMC 3,0 µm\n- odchyłki położenia 0 mm do 600 mm CMC 4,1 µm\nProcedura wewnętrzna; pomiar przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S)","reference":"Procedura wewnętrzna IW-9-LW-AK-01","norm_bases":["IW-9-LW-AK-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość (pomiary współrzędnościowe)","regulatory_area_en":"Length (coordinate measurements)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sprawdziany specjalne Wzorcowanie — Długość (pomiary współrzędnościowe)\nZakres:\n- długość 0 mm do 600 mm CMC 4,2 µm\n- szerokość 0 mm do 400 mm CMC 4,2 µm\n- średnica 0 mm do 250 mm CMC 4,2 µm\n- odchyłka kształtu 0 mm do 1 mm CMC 3,0 µm\n- odchyłki położenia 0 mm do 600 mm CMC 4,1 µm\nProcedura wewnętrzna; pomiar przy użyciu współrzędnościowej maszyny pomiarowej O-Inspect; W stałej lokalizacji (S) Procedura wewnętrzna IW-9-LW-AK-01 Sprawdziany specjalne Wzorcowanie — Dlugosc (pomiary wspolrzednosciowe)\nZakres:\n- dlugosc 0 mm do 600 mm CMC 4,2 µm\n- szerokosc 0 mm do 400 mm CMC 4,2 µm\n- srednica 0 mm do 250 mm CMC 4,2 µm\n- odchylka ksztaltu 0 mm do 1 mm CMC 3,0 µm\n- odchylki polozenia 0 mm do 600 mm CMC 4,1 µm\nProcedura wewnetrzna; pomiar przy uzyciu wspolrzednosciowej maszyny pomiarowej O-Inspect; W stalej lokalizacji (S) Procedura wewnetrzna IW-9-LW-AK-01","search_en":"Special gauges Calibration — Length (coordinate measurements) Internal procedure; measurement using the O-Inspect coordinate measuring machine; At permanent location (S) Length (coordinate measurements) Internal procedure measurement using the O-Inspect coordinate measuring machine At permanent location (S) - length - width - diameter - form deviation - location deviations Internal procedure IW-9-LW-AK-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":77,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"Internal procedure IW-9-LW-AK-01","methodology_de":"Kalibrierung — Länge (Koordinatenmessungen)","parameters_de":[{"name":"- Länge","range":"0 mm bis 600 mm","cmc":"4,2 µm"},{"name":"- Breite","range":"0 mm to 400 mm","cmc":"4,2 µm"},{"name":"- Durchmesser","range":"0 mm to 250 mm","cmc":"4,2 µm"},{"name":"- Formabweichung","range":"0 mm to 1 mm","cmc":"3,0 µm"},{"name":"- Lageabweichungen","range":"0 mm bis 600 mm","cmc":"4,1 µm"}],"reference_de":"Internes Verfahren IW-9-LW-AK-01","regulatory_area_de":"Länge (Koordinatenmessungen)","search_de":"Sonderlehren Kalibrierung — Länge (Koordinatenmessungen) Internes Verfahren; Messung mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S) Länge (Koordinatenmessungen) Internes Verfahren Messung mit dem Koordinatenmessgerät O-Inspect Am festen Standort (S) - Länge - Breite - Durchmesser - Formabweichung - Lageabweichungen Internes Verfahren IW-9-LW-AK-01","technique_de":"Internes Verfahren; Messung mit dem Koordinatenmessgerät O-Inspect; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung mit dem Koordinatenmessgerät O-Inspect","Am festen Standort (S)"],"test_object_de":"Sonderlehren","methodology_zh":"校准 — 长度（坐标测量）","parameters_zh":[{"name":"- 长度","range":"0 mm 至 600 mm","cmc":"4,2 µm"},{"name":"- 宽度","range":"0 mm to 400 mm","cmc":"4,2 µm"},{"name":"- 直径","range":"0 mm to 250 mm","cmc":"4,2 µm"},{"name":"- 形状偏差","range":"0 mm to 1 mm","cmc":"3,0 µm"},{"name":"- 位置偏差","range":"0 mm 至 600 mm","cmc":"4,1 µm"}],"reference_zh":"内部程序 IW-9-LW-AK-01","regulatory_area_zh":"长度（坐标测量）","search_zh":"专用量规 校准 — 长度（坐标测量） 内部程序；使用O-Inspect坐标测量机测量；在固定地点 (S) 长度（坐标测量） 内部程序 使用O-Inspect坐标测量机测量 在固定地点 (S) - 长度 - 宽度 - 直径 - 形状偏差 - 位置偏差 内部程序 IW-9-LW-AK-01","technique_zh":"内部程序；使用O-Inspect坐标测量机测量；在固定地点 (S)","techniques_zh":["内部程序","使用O-Inspect坐标测量机测量","在固定地点 (S)"],"test_object_zh":"专用量规","methodology_cs":"Kalibrace — Délka (souřadnicová měření)","parameters_cs":[{"name":"- délka","range":"0 mm do 600 mm","cmc":"4,2 µm"},{"name":"- šířka","range":"0 mm to 400 mm","cmc":"4,2 µm"},{"name":"- průměr","range":"0 mm to 250 mm","cmc":"4,2 µm"},{"name":"- odchylka tvaru","range":"0 mm to 1 mm","cmc":"3,0 µm"},{"name":"- odchylky polohy","range":"0 mm do 600 mm","cmc":"4,1 µm"}],"reference_cs":"Vnitřní postup IW-9-LW-AK-01","regulatory_area_cs":"Délka (souřadnicová měření)","search_cs":"Speciální kalibry Kalibrace — Délka (souřadnicová měření) Vnitřní postup; měření pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S) Délka (souřadnicová měření) Vnitřní postup měření pomocí souřadnicového měřicího stroje O-Inspect Ve stálé lokalitě (S) - délka - šířka - průměr - odchylka tvaru - odchylky polohy Vnitřní postup IW-9-LW-AK-01","technique_cs":"Vnitřní postup; měření pomocí souřadnicového měřicího stroje O-Inspect; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","měření pomocí souřadnicového měřicího stroje O-Inspect","Ve stálé lokalitě (S)"],"test_object_cs":"Speciální kalibry"}],"has_pdf":true}