SVANTEK Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 146 (Warszawa, Poland). Its accreditation scope covers 10 calibration items in the following areas: Metrology & calibration. Calibrated items include: Vibration calibrators, - acceleration, Human-response vibration meters, Machine vibration meters. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Non-simultaneous comparison method; At permanen….

At a glance

  • Accreditation number: PCA AP 146
  • Calibration items in scope: 10
  • Types of calibrated items: 10
  • Calibration principles used: 2
  • City: Warszawa, Poland
  • Valid until: 04-12-2028
Accreditation number
AP 146
Accreditation body
PCA
Address
ul. Strzygłowska 81, 04-872 Warszawa
City
Warszawa, Poland
Division
Calibration Laboratory
Valid until
04-12-2028

What this laboratory calibrates (10)

Calibration principles (2)

Certificate information

Issue date
06.11.2024
Issue no.
11
Certificate date
27.01.2020
Accreditation cycle
06.11.2024 — 04.12.2028
Approved by
Tadeusz Matras

Accreditation scope — calibration items (10)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand. In other cases, the CMC uncertainty is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Measurement microphones Calibration — Sound pressure (airborne sound)
- pressure sensitivity level — relative to 1 V/Pa; frequency: 250 Hz; frequency: 1 kHz; - 40 dB to - 25 dB · CMC 0,09 dB
Sound pressure (airborne sound)
Internal procedure; Non-simultaneous comparison method; At permanent location (S) IN-05 based on PN-EN 61094-5:2016
2 Sound calibrators Calibration — Sound pressure (airborne sound)
- sound pressure level — relative to 20 µPa; frequency: 1 kHz; 90 dB to 120 dB · CMC 0,08 dB
Sound pressure (airborne sound)
Internal procedure; At permanent location (S) IN-01 based on PN-EN 60942:2018
3 Sound level meters Calibration — Sound pressure (airborne sound)
- response of the sound level meter to the signal from a sound calibrator — relative to 20 μPa; 90 dB to 120 dB · CMC 0,2 dB - response of the sound level meter to electrical test signals — relative to 20 μPa; 20 Hz to 20 kHz; 0 dB to 140 dB · CMC 0,2 dB - free-field frequency response of the sound level meter — 20 Hz to 20 kHz; 125 Hz · CMC 0,3 dB - free-field frequency response of the sound level meter — 20 Hz to 20 kHz; 1 kHz · CMC 0,3 dB - free-field frequency response of the sound level meter — 20 Hz to 20 kHz; 4 kHz · CMC 0,3 dB - free-field frequency response of the sound level meter — 20 Hz to 20 kHz; 8 kHz · CMC 0,4 dB
Sound pressure (airborne sound)
Internal procedure; At permanent location (S) IN-02 based on PN-EN 61672-3:2007, PN-EN 61672-3:2014
4 Octave-band and one-third-octave-band filters Calibration — Sound pressure (airborne sound)
- relative attenuation — 20 Hz to 20 kHz; 0 dB to 100 dB; ≤ 70 dB · CMC 0,2 dB - relative attenuation — 20 Hz to 20 kHz; 0 dB to 100 dB; > 70 dB · CMC 0,3 dB
Sound pressure (airborne sound)
Internal procedure; At permanent location (S) IN-04 based on PN-EN 61260:2000, PN-EN 61260:2016
5 Personal sound exposure meters: Calibration — Sound pressure (airborne sound)
- response of the sound exposure meter to the signal from a sound calibrator — time 60 s to 120 s; 90 dB to 120 dB · CMC 4,0 % - response of the sound exposure meter to electrical test signals — time 60 s to 120 s; 0,3 Pa²h to 105 Pa²h · CMC 3,0 % - free-field frequency response of the sound exposure meter — time 60 s to 120 s; relative to 20 μPa; 63 Hz to 4 kHz · CMC 0,4 dB - free-field frequency response of the sound exposure meter — time 60 s to 120 s; relative to 20 μPa; 4 kHz to 8 kHz · CMC 0,6 dB
Sound pressure (airborne sound)
Internal procedure; At permanent location (S) IN-03 based on PN-EN 61252:2000
6 Vibration transducers Calibration — Acceleration of mechanical vibration Sensitivity of vibration transducers
- reference sensitivity — 16 Hz and 80 Hz; 0,1 pC·m⁻¹·s² to 1000 pC·m⁻¹·s² · CMC 1,8 % - reference sensitivity — 16 Hz and 80 Hz; 0,1 mV·m⁻¹·s² to 1000 mV·m⁻¹·s² · CMC 1,8 % - frequency response — 0,5 Hz to 2 kHz; 0,5 Hz to 0,8 Hz · CMC 2,3 % - frequency response — 0,5 Hz to 2 kHz; 1 Hz to 16 Hz · CMC 2,1 % - frequency response — 0,5 Hz to 2 kHz; 20 Hz to 500 Hz · CMC 1,8 % - frequency response — 0,5 Hz to 2 kHz; 630 Hz to 2000 Hz · CMC 2,1 %
Acceleration of mechanical vibration Sensitivity of vibration transducers
Internal procedure; At permanent location (S) IN-07 based on ISO 16063-21:2003
7 Human-response vibration meters Calibration — Acceleration of mechanical vibration Sensitivity of vibration transducers
- response of the meter to the reference signal — 15,915 Hz; 1 m·s⁻² · CMC 1,8% - response of the meter to the reference signal — 79,58 Hz; 10 m·s⁻² for · CMC 1,8% - frequency responses of the meter for a mechanical signal for filters Wₖ, W_D, Wₕ — 0,63 Hz · CMC 3,3 % - frequency responses of the meter for a mechanical signal for filters Wₖ, W_D, Wₕ — 0,8 Hz to 1 Hz · CMC 2,9 % - frequency responses of the meter for a mechanical signal for filters Wₖ, W_D, Wₕ — 1,25 Hz to 125 Hz · CMC 2,5 % - frequency responses of the meter for a mechanical signal for filters Wₖ, W_D, Wₕ — 5 Hz to 20 Hz · CMC 2,3 % - frequency responses of the meter for a mechanical signal for filters Wₖ, W_D, Wₕ — 25 Hz to 500 Hz · CMC 2,1 % - frequency responses of the meter for a mechanical signal for filters Wₖ, W_D, Wₕ — 630 Hz to 1000 Hz · CMC 2,3 % - determination of the linearity errors of the meter for a mechanical signal — 15,915 Hz; 0,1 m·s⁻² to 25 m·s⁻² · CMC 1,8 % - determination of the linearity errors of the meter for a mechanical signal — 79,58 Hz; 5 m·s⁻² to 100 m·s⁻² for · CMC 1,8 %
Acceleration of mechanical vibration Sensitivity of vibration transducers
Internal procedure; At permanent location (S) IN-08 based on PN-EN ISO 8041-1:2017
8 Vibration calibrators Calibration — Acceleration of mechanical vibration Sensitivity of vibration transducers
16 Hz: 1 m·s⁻² · CMC 1,5 % 80 Hz: 10 m·s⁻² · CMC 1,5 % 160 Hz: 10 m·s⁻² · CMC 1,5 % 630 Hz: 1 m·s⁻² · CMC 1,5 %
Acceleration of mechanical vibration Sensitivity of vibration transducers
Internal procedure; At permanent location (S) IN-06 based on PN-EN ISO 8041-1:2017
9 Vibration calibrators
- acceleration
Calibration — Acceleration of mechanical vibration Sensitivity of vibration transducers
16 Hz: 1 m·s⁻² · CMC 1,5 % 80 Hz: 10 m·s⁻² · CMC 1,5 % 160 Hz: 10 m·s⁻² · CMC 1,5 % 630 Hz: 1 m·s⁻² · CMC 1,5 %
Acceleration of mechanical vibration Sensitivity of vibration transducers
Internal procedure; At permanent location (S) IN-06 based on PN-EN ISO 8041-1:2017
10 Machine vibration meters Calibration — Acceleration of mechanical vibration Sensitivity of vibration transducers
- response of the meter to the reference signal for a mechanical signal — 80 Hz; 10 m·s⁻² · CMC 1,8 % - frequency responses of the meter for a mechanical signal — 8 Hz to 20 Hz · CMC 2,3 % - frequency responses of the meter for a mechanical signal — 25 Hz to 500 Hz · CMC 2,1 % - frequency responses of the meter for a mechanical signal — 630 Hz to 1600 Hz · CMC 2,3 % - frequency responses of the meter for a mechanical signal — 2000 Hz · CMC 2,4 %
Acceleration of mechanical vibration Sensitivity of vibration transducers
Internal procedure; At permanent location (S) IN-10

Reference standards (18)

IN-01
IN-02
IN-03
IN-04
IN-05
IN-06
IN-07
IN-08
IN-10
ISO 16063-21:2003
PN-EN 60942:2018
PN-EN 61094-5:2016
PN-EN 61252:2000
PN-EN 61260:2000
PN-EN 61260:2016
PN-EN 61672-3:2007
PN-EN 61672-3:2014
PN-EN ISO 8041-1:2017