🇵🇱 Instytut Automatyki Systemów Energetycznych Sp. z o.o. PL
Metrology & calibration
Instytut Automatyki Systemów Energetycznych Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 145 (Wrocław, Poland). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Combination wave (surge) generators, Electrical fast transient/burst (EFT/B) generators, Electrostatic discharge (ESD) generators. Most frequently used calibration principles: Internal procedure; At permanent location (S).
At a glance
- Accreditation number: PCA AP 145
- Calibration items in scope: 3
- Types of calibrated items: 3
- Calibration principles used: 1
- City: Wrocław, Poland
- Valid until: 18-11-2028
- Accreditation number
- AP 145
- Accreditation body
- PCA
- Address
- ul. Wystawowa 1, 51-618 Wrocław
- City
- Wrocław, Poland
- Division
- Laboratorium Badawcze i Wzorcujące
- Valid until
- 18-11-2028
What this laboratory calibrates (3)
- Combination wave (surge) generators — 1 calibration item
- Electrical fast transient/burst (EFT/B) generators — 1 calibration item
- Electrostatic discharge (ESD) generators — 1 calibration item
Calibration principles (1)
- Internal procedure; At permanent location (S) — 3 calibration items
Certificate information
- Issue date
- 16.10.2025
- Issue no.
- 8
- Certificate date
- 27.10.2020
- Accreditation cycle
- 28.10.2024 — 18.11.2028
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (3)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Electrostatic discharge (ESD) generators | Calibration — High-frequency electrical quantities output voltage — 2 kV to 30 kV · CMC 3,0 % peak value of discharge current — 5 A to 35 A · CMC 6,0 % discharge current rise time — 0,5 ns to 1,5 ns · CMC 8,0 % discharge current at 30 ns — 2 A to 21 A · CMC 8,0 % discharge current at 60 ns — 1 A to 11 A · CMC 8,0 % High-frequency electrical quantities |
Internal procedure; At permanent location (S) | LB-IT07 w oparciu o PN-EN 61000-4-2:2011 | |
| 2 | Electrical fast transient/burst (EFT/B) generators | Calibration — High-frequency electrical quantities peak voltage — 0,2 kV to 4,8 kV · CMC 6,0 % pulse rise time — 3 ns to 7 ns · CMC 5,5 % pulse duration — 30 ns to 200 ns · CMC 4,0 % burst duration — 0,5 ms to 20 ms · CMC 4,0 % burst period — 200 ms to 400 ms · CMC 4,0 % pulse repetition frequency within a burst — 2 Hz to 120 kHz · CMC 4,0 % High-frequency electrical quantities |
Internal procedure; At permanent location (S) | LB-IT05 w oparciu o PN-EN 61000-4-4:2010 +A1:2010; LB-IT05A w oparciu o PN-EN 61000-4-4:2013-05 | |
| 3 | Combination wave (surge) generators | Calibration — High-frequency electrical quantities open-circuit peak voltage — 0,2 kV to 7 kV · CMC 5 % open-circuit voltage front time — 0,5 μs to 20 μs · CMC 7 % open-circuit voltage duration — 10 μs to 1000 μs · CMC 6 % short-circuit peak current — 5 A to 3800 A · CMC 5 % short-circuit current front time — 1,5 μs to 15 μs · CMC 5 % short-circuit current duration — 15 μs to 400 μs · CMC 6 % effective output impedance — 1,5 Ω to 45 Ω · CMC 6 % High-frequency electrical quantities |
Internal procedure; At permanent location (S) | LB-IT06 w oparciu o PN-EN 61000-4-5:2010; LB-IT06A w oparciu o PN-EN 61000-4-5:2014-10 | |
Reference standards (10)
LB-IT05
LB-IT05A
LB-IT06
LB-IT06A
LB-IT07
PN-EN 61000-4-2:2011
PN-EN 61000-4-4:2010 +A1:2010
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5:2010
PN-EN 61000-4-5:2014-10