{"lab":{"_id":"6ae132eaff068247617088b5","accr_number":"AP 145","country":"PL","imported_at":"2026-10-27T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"ul. Wystawowa 1, 51-618 Wrocław","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"27.10.2020","city":"Wrocław","cmc_note":"Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The measurement uncertainty value for CMC expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand.","cycle_from":"28.10.2024","cycle_to":"18.11.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"8.01","pl":"wielkości elektryczne w.cz","en":"high-frequency electrical quantities"}],"has_en":true,"has_zh":false,"issue":{"no":"8","date":"16.10.2025"},"issue_date":"16.10.2025","issue_number":"8","lab_division":"Laboratorium Badawcze i Wzorcujące","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[17.0773185,51.1068875]},"map_coord":[51.1068875,17.0773185],"map_geo":"nominatim-street","methods_count":3,"name":"Instytut Automatyki Systemów Energetycznych Sp. z o.o.","parse_date":"2026-10-27T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-10-27T12:00:00.000Z","pdf_files":["AP_145.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: wielkości elektryczne w.cz. W stałej lokalizacji (S).","search_text":"instytut automatyki systemów energetycznych sp. z o.o. laboratorium badawcze i wzorcujące ul. wystawowa 1, 51-618 wrocław laboratorium wzorcujące. wielkości mierzone: wielkości elektryczne w.cz. w stałej lokalizacji (s). ap 145 ap145 laboratorium wzorcujące wzorcowanie kalibracja high-frequency electrical quantities instytut automatyki systemow energetycznych sp. z o.o. laboratorium badawcze i wzorcujace ul. wystawowa 1, 51-618 wroclaw laboratorium wzorcujace. wielkosci mierzone: wielkosci elektryczne w.cz. w stalej lokalizacji (s). ap 145 ap145 laboratorium wzorcujace wzorcowanie kalibracja high-frequency electrical quantities","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20145,podmiot.html","source_pdf_sha256":"88021d196a96ed0b2a51096e7e755b1c5eef791f5e89a9ecea7710aff53f3fa9","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/10/27/f31770d6892601ad74eefda508a9d17d/AP%20145.pdf","status":"active","updated_at":"2026-10-27T12:00:00.000Z","valid_from":"19-11-2012","valid_until":"18-11-2028","website":"iase.wroc.pl"},"methods":[{"_id":"cf859bf73383f950e9a83ff3","lab_id":"6ae132eaff068247617088b5","country":"PL","accr_number":"AP 145","accr_body":"PCA","test_object":"Generatory wyładowań elektrostatycznych (ESD)","test_object_en":"Electrostatic discharge (ESD) generators","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — High-frequency electrical quantities","parameters":[{"name":"napięcie wyjściowe","range":"2 kV do 30 kV","cmc":"3,0 %"},{"name":"wartość szczytowa prądu wyładowania","range":"5 A do 35 A","cmc":"6,0 %"},{"name":"czas narastania prądu wyładowania","range":"0,5 ns do 1,5 ns","cmc":"8,0 %"},{"name":"prąd wyładowania po 30 ns","range":"2 A do 21 A","cmc":"8,0 %"},{"name":"prąd wyładowania po 60 ns","range":"1 A do 11 A","cmc":"8,0 %"}],"parameters_en":[{"name":"output voltage","range":"2 kV to 30 kV","cmc":"3,0 %"},{"name":"peak value of discharge current","range":"5 A to 35 A","cmc":"6,0 %"},{"name":"discharge current rise time","range":"0,5 ns to 1,5 ns","cmc":"8,0 %"},{"name":"discharge current at 30 ns","range":"2 A to 21 A","cmc":"8,0 %"},{"name":"discharge current at 60 ns","range":"1 A to 11 A","cmc":"8,0 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nnapięcie wyjściowe 2 kV do 30 kV CMC 3,0 %\nwartość szczytowa prądu wyładowania 5 A do 35 A CMC 6,0 %\nczas narastania prądu wyładowania 0,5 ns do 1,5 ns CMC 8,0 %\nprąd wyładowania po 30 ns 2 A do 21 A CMC 8,0 %\nprąd wyładowania po 60 ns 1 A do 11 A CMC 8,0 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LB-IT07 w oparciu o PN-EN 61000-4-2:2011","norm_bases":["LB-IT07","PN-EN 61000-4-2:2011"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"High-frequency electrical quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Generatory wyładowań elektrostatycznych (ESD) Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nnapięcie wyjściowe 2 kV do 30 kV CMC 3,0 %\nwartość szczytowa prądu wyładowania 5 A do 35 A CMC 6,0 %\nczas narastania prądu wyładowania 0,5 ns do 1,5 ns CMC 8,0 %\nprąd wyładowania po 30 ns 2 A do 21 A CMC 8,0 %\nprąd wyładowania po 60 ns 1 A do 11 A CMC 8,0 %\nProcedura wewnętrzna; W stałej lokalizacji (S) LB-IT07 w oparciu o PN-EN 61000-4-2:2011 Generatory wyladowan elektrostatycznych (ESD) Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\nnapiecie wyjsciowe 2 kV do 30 kV CMC 3,0 %\nwartosc szczytowa pradu wyladowania 5 A do 35 A CMC 6,0 %\nczas narastania pradu wyladowania 0,5 ns do 1,5 ns CMC 8,0 %\nprad wyladowania po 30 ns 2 A do 21 A CMC 8,0 %\nprad wyladowania po 60 ns 1 A do 11 A CMC 8,0 %\nProcedura wewnetrzna; W stalej lokalizacji (S) LB-IT07 w oparciu o PN-EN 61000-4-2:2011","search_en":"Electrostatic discharge (ESD) generators Calibration — High-frequency electrical quantities\nScope:\noutput voltage 2 kV to 30 kV CMC 3,0 %\npeak value of discharge current 5 A to 35 A CMC 6,0 %\ndischarge current rise time 0,5 ns to 1,5 ns CMC 8,0 %\ndischarge current at 30 ns 2 A to 21 A CMC 8,0 %\ndischarge current at 60 ns 1 A to 11 A CMC 8,0 %\nInternal procedure; At permanent location (S) LB-IT07 w oparciu o PN-EN 61000-4-2:2011","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1"},{"_id":"75a169b664e4ebaf85b398aa","lab_id":"6ae132eaff068247617088b5","country":"PL","accr_number":"AP 145","accr_body":"PCA","test_object":"Generatory serii szybkich elektrycznych stanów przejściowych (EFT/B)","test_object_en":"Electrical fast transient/burst (EFT/B) generators","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — High-frequency electrical quantities","parameters":[{"name":"wartość szczytowa napięcia","range":"0,2 kV do 4,8 kV","cmc":"6,0 %"},{"name":"czas narastania impulsu","range":"3 ns do 7 ns","cmc":"5,5 %"},{"name":"czas trwania impulsu","range":"30 ns do 200 ns","cmc":"4,0 %"},{"name":"czas trwania serii impulsów","range":"0,5 ms do 20 ms","cmc":"4,0 %"},{"name":"okres serii impulsów","range":"200 ms do 400 ms","cmc":"4,0 %"},{"name":"częstotliwość impulsów w serii","range":"2 Hz do 120 kHz","cmc":"4,0 %"}],"parameters_en":[{"name":"peak voltage","range":"0,2 kV to 4,8 kV","cmc":"6,0 %"},{"name":"pulse rise time","range":"3 ns to 7 ns","cmc":"5,5 %"},{"name":"pulse duration","range":"30 ns to 200 ns","cmc":"4,0 %"},{"name":"burst duration","range":"0,5 ms to 20 ms","cmc":"4,0 %"},{"name":"burst period","range":"200 ms to 400 ms","cmc":"4,0 %"},{"name":"pulse repetition frequency within a burst","range":"2 Hz to 120 kHz","cmc":"4,0 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nwartość szczytowa napięcia 0,2 kV do 4,8 kV CMC 6,0 %\nczas narastania impulsu 3 ns do 7 ns CMC 5,5 %\nczas trwania impulsu 30 ns do 200 ns CMC 4,0 %\nczas trwania serii impulsów 0,5 ms do 20 ms CMC 4,0 %\nokres serii impulsów 200 ms do 400 ms CMC 4,0 %\nczęstotliwość impulsów w serii 2 Hz do 120 kHz CMC 4,0 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LB-IT05 w oparciu o PN-EN 61000-4-4:2010 +A1:2010; LB-IT05A w oparciu o PN-EN 61000-4-4:2013-05","norm_bases":["LB-IT05","PN-EN 61000-4-4:2010 +A1:2010","LB-IT05A","PN-EN 61000-4-4:2013-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"High-frequency electrical quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Generatory serii szybkich elektrycznych stanów przejściowych (EFT/B) Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nwartość szczytowa napięcia 0,2 kV do 4,8 kV CMC 6,0 %\nczas narastania impulsu 3 ns do 7 ns CMC 5,5 %\nczas trwania impulsu 30 ns do 200 ns CMC 4,0 %\nczas trwania serii impulsów 0,5 ms do 20 ms CMC 4,0 %\nokres serii impulsów 200 ms do 400 ms CMC 4,0 %\nczęstotliwość impulsów w serii 2 Hz do 120 kHz CMC 4,0 %\nProcedura wewnętrzna; W stałej lokalizacji (S) LB-IT05 w oparciu o PN-EN 61000-4-4:2010 +A1:2010; LB-IT05A w oparciu o PN-EN 61000-4-4:2013-05 Generatory serii szybkich elektrycznych stanow przejsciowych (EFT/B) Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\nwartosc szczytowa napiecia 0,2 kV do 4,8 kV CMC 6,0 %\nczas narastania impulsu 3 ns do 7 ns CMC 5,5 %\nczas trwania impulsu 30 ns do 200 ns CMC 4,0 %\nczas trwania serii impulsow 0,5 ms do 20 ms CMC 4,0 %\nokres serii impulsow 200 ms do 400 ms CMC 4,0 %\nczestotliwosc impulsow w serii 2 Hz do 120 kHz CMC 4,0 %\nProcedura wewnetrzna; W stalej lokalizacji (S) LB-IT05 w oparciu o PN-EN 61000-4-4:2010 +A1:2010; LB-IT05A w oparciu o PN-EN 61000-4-4:2013-05","search_en":"Electrical fast transient/burst (EFT/B) generators Calibration — High-frequency electrical quantities\nScope:\npeak voltage 0,2 kV to 4,8 kV CMC 6,0 %\npulse rise time 3 ns to 7 ns CMC 5,5 %\npulse duration 30 ns to 200 ns CMC 4,0 %\nburst duration 0,5 ms to 20 ms CMC 4,0 %\nburst period 200 ms to 400 ms CMC 4,0 %\npulse repetition frequency within a burst 2 Hz to 120 kHz CMC 4,0 %\nInternal procedure; At permanent location (S) LB-IT05 w oparciu o PN-EN 61000-4-4:2010 +A1:2010; LB-IT05A w oparciu o PN-EN 61000-4-4:2013-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1"},{"_id":"e05af3ea023ac9c1dbb5afc2","lab_id":"6ae132eaff068247617088b5","country":"PL","accr_number":"AP 145","accr_body":"PCA","test_object":"Generatory przebiegu złożonego","test_object_en":"Combination wave (surge) generators","methodology":"Wzorcowanie — Wielkości elektryczne w.cz.","methodology_en":"Calibration — High-frequency electrical quantities","parameters":[{"name":"wartość szczytowa napięcia obwodu otwartego","range":"0,2 kV do 7 kV","cmc":"5 %"},{"name":"czas trwania czoła napięcia obwodu otwartego","range":"0,5 μs do 20 μs","cmc":"7 %"},{"name":"czas trwania napięcia obwodu otwartego","range":"10 μs do 1000 μs","cmc":"6 %"},{"name":"wartość szczytowa prądu zwarciowego","range":"5 A do 3800 A","cmc":"5 %"},{"name":"czas trwania czoła prądu zwarciowego","range":"1,5 μs do 15 μs","cmc":"5 %"},{"name":"czas trwania prądu zwarciowego","range":"15 μs do 400 μs","cmc":"6 %"},{"name":"efektywna impedancja wyjściowa","range":"1,5 Ω do 45 Ω","cmc":"6 %"}],"parameters_en":[{"name":"open-circuit peak voltage","range":"0,2 kV to 7 kV","cmc":"5 %"},{"name":"open-circuit voltage front time","range":"0,5 μs to 20 μs","cmc":"7 %"},{"name":"open-circuit voltage duration","range":"10 μs to 1000 μs","cmc":"6 %"},{"name":"short-circuit peak current","range":"5 A to 3800 A","cmc":"5 %"},{"name":"short-circuit current front time","range":"1,5 μs to 15 μs","cmc":"5 %"},{"name":"short-circuit current duration","range":"15 μs to 400 μs","cmc":"6 %"},{"name":"effective output impedance","range":"1,5 Ω to 45 Ω","cmc":"6 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nwartość szczytowa napięcia obwodu otwartego 0,2 kV do 7 kV CMC 5 %\nczas trwania czoła napięcia obwodu otwartego 0,5 μs do 20 μs CMC 7 %\nczas trwania napięcia obwodu otwartego 10 μs do 1000 μs CMC 6 %\nwartość szczytowa prądu zwarciowego 5 A do 3800 A CMC 5 %\nczas trwania czoła prądu zwarciowego 1,5 μs do 15 μs CMC 5 %\nczas trwania prądu zwarciowego 15 μs do 400 μs CMC 6 %\nefektywna impedancja wyjściowa 1,5 Ω do 45 Ω CMC 6 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"LB-IT06 w oparciu o PN-EN 61000-4-5:2010; LB-IT06A w oparciu o PN-EN 61000-4-5:2014-10","norm_bases":["LB-IT06","PN-EN 61000-4-5:2010","LB-IT06A","PN-EN 61000-4-5:2014-10"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektryczne w.cz.","regulatory_area_en":"High-frequency electrical quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Generatory przebiegu złożonego Wzorcowanie — Wielkości elektryczne w.cz.\nZakres:\nwartość szczytowa napięcia obwodu otwartego 0,2 kV do 7 kV CMC 5 %\nczas trwania czoła napięcia obwodu otwartego 0,5 μs do 20 μs CMC 7 %\nczas trwania napięcia obwodu otwartego 10 μs do 1000 μs CMC 6 %\nwartość szczytowa prądu zwarciowego 5 A do 3800 A CMC 5 %\nczas trwania czoła prądu zwarciowego 1,5 μs do 15 μs CMC 5 %\nczas trwania prądu zwarciowego 15 μs do 400 μs CMC 6 %\nefektywna impedancja wyjściowa 1,5 Ω do 45 Ω CMC 6 %\nProcedura wewnętrzna; W stałej lokalizacji (S) LB-IT06 w oparciu o PN-EN 61000-4-5:2010; LB-IT06A w oparciu o PN-EN 61000-4-5:2014-10 Generatory przebiegu zlozonego Wzorcowanie — Wielkosci elektryczne w.cz.\nZakres:\nwartosc szczytowa napiecia obwodu otwartego 0,2 kV do 7 kV CMC 5 %\nczas trwania czola napiecia obwodu otwartego 0,5 μs do 20 μs CMC 7 %\nczas trwania napiecia obwodu otwartego 10 μs do 1000 μs CMC 6 %\nwartosc szczytowa pradu zwarciowego 5 A do 3800 A CMC 5 %\nczas trwania czola pradu zwarciowego 1,5 μs do 15 μs CMC 5 %\nczas trwania pradu zwarciowego 15 μs do 400 μs CMC 6 %\nefektywna impedancja wyjsciowa 1,5 Ω do 45 Ω CMC 6 %\nProcedura wewnetrzna; W stalej lokalizacji (S) LB-IT06 w oparciu o PN-EN 61000-4-5:2010; LB-IT06A w oparciu o PN-EN 61000-4-5:2014-10","search_en":"Combination wave (surge) generators Calibration — High-frequency electrical quantities\nScope:\nopen-circuit peak voltage 0,2 kV to 7 kV CMC 5 %\nopen-circuit voltage front time 0,5 μs to 20 μs CMC 7 %\nopen-circuit voltage duration 10 μs to 1000 μs CMC 6 %\nshort-circuit peak current 5 A to 3800 A CMC 5 %\nshort-circuit current front time 1,5 μs to 15 μs CMC 5 %\nshort-circuit current duration 15 μs to 400 μs CMC 6 %\neffective output impedance 1,5 Ω to 45 Ω CMC 6 %\nInternal procedure; At permanent location (S) LB-IT06 w oparciu o PN-EN 61000-4-5:2010; LB-IT06A w oparciu o PN-EN 61000-4-5:2014-10","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1"}],"has_pdf":true}