Metrology & calibration
Instytut Meteorologii i Gospodarki Wodnej - Państwowy Instytut Badawczy is a calibration laboratory accredited by PCA under number AP 126 (Warszawa, Poland). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electrical thermometers, Electronic pressure gauges, Hygrometers, Resistance thermometer sensors. Most frequently used calibration principles: Internal procedure; At permanent location (S).
At a glance
- Accreditation number: PCA AP 126
- Calibration items in scope: 3
- Types of calibrated items: 6
- Calibration principles used: 1
- City: Warszawa, Poland
- Valid until: 13-07-2029
- Accreditation number
- AP 126
- Accreditation body
- PCA
- Address
- ul. Podleśna 61, 01-673 Warszawa
- City
- Warszawa, Poland
- Division
- Centralne Laboratorium Aparatury Pomiarowej
- Valid until
- 13-07-2029
What this laboratory calibrates (6)
- Electrical thermometers — 1 calibration item
- Electronic pressure gauges — 1 calibration item
- Hygrometers — 1 calibration item
- Resistance thermometer sensors — 1 calibration item
- Temperature transducers — 1 calibration item
- Transducers — 1 calibration item
Calibration principles (1)
- Internal procedure; At permanent location (S) — 3 calibration items
Certificate information
- Issue date
- 17.06.2025
- Issue no.
- 14
- Certificate date
- 28.06.2019
- Accreditation cycle
- 17.06.2025 — 13.07.2029
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (3)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Hygrometers Transducers |
Calibration — Relative humidity at 20 °C — 10 %rh to 40 %rh · CMC 1,5 %rh at 20 °C — 40 %rh to 60 %rh · CMC 1,8 %rh at 20 °C — 60 %rh to 80 %rh · CMC 2,2 %rh at 20 °C — 80 %rh to 95 %rh · CMC 2,5 %rh Relative humidity |
Internal procedure; At permanent location (S) | P.W.-HCB-02/CLAP | |
| 2 | Electronic pressure gauges | Calibration — Pressure absolute pressure (gas medium) — 600 hPa to 1100 hPa · CMC 0,17 hPa Pressure |
Internal procedure; At permanent location (S) | P.W.-PCB-1/CLAP w oparciu o Euramet/cg-17/v.4.1 | |
| 3 | Resistance thermometer sensors Temperature transducers Electrical thermometers |
Calibration — Temperature (electrical thermometry) -30 °C to 50 °C · CMC 0,05 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | P.W.-TCB-2/CLAP P.W.-TCB-3/CLAP P.W.-TCB-4/CLAP | |
Reference standards (6)
Euramet/cg-17/v.4.1
P.W.-HCB-02/CLAP
P.W.-PCB-1/CLAP
P.W.-TCB-2/CLAP
P.W.-TCB-3/CLAP
P.W.-TCB-4/CLAP