🇵🇱 Instytut Niskich Temperatur i Badań Strukturalnych PAN PL

PCA AP 125 • Wrocław, Poland • 3 calibration items

Metrology & calibration

Instytut Niskich Temperatur i Badań Strukturalnych PAN is a calibration laboratory accredited by PCA under number AP 125 (Wrocław, Poland). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Resistance thermometer sensors, Electrical thermometers (including electronic). Most frequently used calibration principles: Internal procedure; Comparison method; At permanent location (S), Internal procedure; Calibration by the ITS-90 fixed point method; A….

At a glance

  • Accreditation number: PCA AP 125
  • Calibration items in scope: 3
  • Types of calibrated items: 2
  • Calibration principles used: 2
  • City: Wrocław, Poland
  • Valid until: 24-05-2029
Accreditation number
AP 125
Accreditation body
PCA
Address
ul. Okólna 2, 50-422 Wrocław
City
Wrocław, Poland
Division
Laboratorium Wzorca Temperatury
Valid until
24-05-2029

What this laboratory calibrates (2)

Calibration principles (2)

Certificate information

Issue date
28.04.2025
Issue no.
13
Certificate date
03.06.2019
Accreditation cycle
28.04.2025 — 24.05.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (3)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Resistance thermometer sensors Calibration — Temperature (electrical thermometry)
triple point of mercury — Hg (234,3156 K) (-38,8344 °C) · CMC 0,38 mK triple point of water — H2O (273,16 K) (0,01 °C) · CMC 0,65 mK melting point of gallium — Ga (302,9146 K) (29,7646 °C) · CMC 1,00 mK freezing point of indium — In (429,7485 K) (156,5985 °C) · CMC 2,54 mK
Temperature (electrical thermometry)
Internal procedure; Calibration by the ITS-90 fixed point method; At permanent location (S) IW/S2/01
2 Resistance thermometer sensors Calibration — Temperature (electrical thermometry)
-80 °C to 95 °C · CMC 0,01 °C 95 °C to 200 °C · CMC 0,02 °C 200 °C to 400 °C · CMC 0,1 °C
Temperature (electrical thermometry)
Internal procedure; Comparison method; At permanent location (S) IW/S2/03
3 Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry)
-80 °C to 95 °C · CMC 0,01 °C 95 °C to 200 °C · CMC 0,02 °C 200 °C to 400 °C · CMC 0,1 °C
Temperature (electrical thermometry)
Internal procedure; Comparison method; At permanent location (S) IW/S2/02

Reference standards (3)

IW/S2/01
IW/S2/02
IW/S2/03

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20125