POL-EKO Laboratorium Pomiarowe Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 115 (Wodzisław Śląski, Poland). Its accreditation scope covers 14 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electrical thermometers (including electronic), Bar sieves, Climatic chambers, Laboratory test sieves. Most frequently used calibration principles: Internal procedure; At permanent location (S) and outside of it (P), Internal procedure; Measurement using a coordinate measuring micros…, Internal procedure; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 115
  • Calibration items in scope: 14
  • Types of calibrated items: 11
  • Calibration principles used: 7
  • City: Wodzisław Śląski, Poland
  • Valid until: 27-05-2028
Accreditation number
AP 115
Accreditation body
PCA
Address
ul. Kokoszycka 172 C, 44-300 Wodzisław Śląski
City
Wodzisław Śląski, Poland
Valid until
27-05-2028

What this laboratory calibrates (11)

Calibration principles (7)

Certificate information

Issue date
17.03.2026
Issue no.
19
Certificate date
06.04.2020
Accreditation cycle
21.05.2024 — 27.05.2028
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (14)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Laboratory test sieves Calibration — Length
0,02 mm to 10 mm · CMC 3 μm 10 mm to 50 mm · CMC 50 μm 50 mm to 125 mm · CMC 110 μm
Length
Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S) PLP-SL based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000
2 Bar sieves Calibration — Length
2,5 mm to 10 mm · CMC 3,0 μm 10 mm to 50 mm · CMC 50 μm
Length
Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S) PLP-SL based on PN-EN 933-3:2012
3 Sieve baskets of woven wire cloth Calibration — Length
0,02 mm to 0,5 mm · CMC 3 μm
Length
Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S) PLP-SL based on PN-ISO 3310-1:2000
4 Laboratory test sieves Calibration — Length
10 mm to 50 mm · CMC 50 μm 50 mm to 125 mm · CMC 110 μm
Length
Internal procedure; Measurement using a calliper; At permanent location (S) PLP-SL based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000
5 Bar sieves Calibration — Length
10 mm to 50 mm · CMC 50 μm
Length
Internal procedure; Measurement using a calliper; At permanent location (S) PLP-SL based on PN-EN 933-3:2012
6 Thermohygrometers Calibration — Relative humidity
temperature range 10 °C to 20 °C — 22 %rh to 98 %rh · CMC 2,5 %rh temperature range 20 °C to 40 °C — 20 %rh to 98 %rh · CMC 2,5 %rh temperature range 40 °C to 60 °C — 20 %rh to 80 %rh · CMC 2,5 %rh
Relative humidity
Internal procedure; Direct method; At permanent location (S) PLP-RH
7 Climatic chambers Calibration — Relative humidity
temperature range 10 °C to 20 °C — 22 %rh to 98 %rh · CMC 3,0%rh 1) temperature range 20 °C to 40 °C — 20 %rh to 98 %rh · CMC 3,0%rh 1) temperature range 40 °C to 60 °C — 20 %rh to 80 %rh · CMC 3,0%rh 1)
Relative humidity
Internal procedure; Direct method; At permanent location (S) and outside of it (P) PLP-KK
8 Climatic chambers
Thermostatic chambers
Calibration — Temperature (electrical thermometry)
-80 °C to -25 °C · CMC 0,5 °C 1) -25 °C to 200 °C · CMC 0,15 °C 1)
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) and outside of it (P) PLP-BRT, PLP-PRT
9 Liquid thermostats Calibration — Temperature (electrical thermometry)
-25 °C to 200 °C · CMC 0,15 °C 1)
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) and outside of it (P) PLP-LW
10 Furnaces Calibration — Temperature (electrical thermometry)
100 °C to 1100 °C · CMC 3,0 °C 1)
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) and outside of it (P) PLP-PL
11 Steam sterilization chambers (autoclaves, Koch apparatus etc.) Calibration — Temperature (electrical thermometry)
60 °C to 140 °C · CMC 0,5 °C 1)
Temperature (electrical thermometry)
Internal procedure; Outside of permanent location (P) PLP-AT
12 Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry)
-95 °C to -25 °C · CMC 0,2 °C -25 °C to 80 °C · CMC 0,05 °C 80 °C to 200 °C · CMC 0,06 °C 200 ºC°C to 1100 °C · CMC 2,5 °C
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) PLP-TE
13 Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry)
-95 °C to 200 °C · CMC 0,2 °C 200 °C to 1000 °C · CMC 2,5 °C
Temperature (electrical thermometry)
Internal procedure; Outside of permanent location (P) PLP-TE
14 Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Calibration — Temperature (electrical thermometry)
-40 °C to 60 °C · CMC 0,2 °C 60 °C to 140 °C · CMC 0,3 °C
Temperature (electrical thermometry)
Internal procedure; At permanent location (S) PLP-RT

Reference standards (13)

PLP-AT
PLP-BRT
PLP-KK
PLP-LW
PLP-PL
PLP-PRT
PLP-RH
PLP-RT
PLP-SL
PLP-TE
PN-EN 933-3:2012
PN-ISO 3310-1:2000
PN-ISO 3310-2:2000