🇵🇱 POL-EKO Laboratorium Pomiarowe Sp. z o.o. PL
Metrology & calibration
POL-EKO Laboratorium Pomiarowe Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 115 (Wodzisław Śląski, Poland). Its accreditation scope covers 14 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electrical thermometers (including electronic), Bar sieves, Climatic chambers, Laboratory test sieves. Most frequently used calibration principles: Internal procedure; At permanent location (S) and outside of it (P), Internal procedure; Measurement using a coordinate measuring micros…, Internal procedure; At permanent location (S).
At a glance
- Accreditation number: PCA AP 115
- Calibration items in scope: 14
- Types of calibrated items: 11
- Calibration principles used: 7
- City: Wodzisław Śląski, Poland
- Valid until: 27-05-2028
- Accreditation number
- AP 115
- Accreditation body
- PCA
- Address
- ul. Kokoszycka 172 C, 44-300 Wodzisław Śląski
- City
- Wodzisław Śląski, Poland
- Valid until
- 27-05-2028
What this laboratory calibrates (11)
- Electrical thermometers (including electronic) — 3 calibration items
- Bar sieves — 2 calibration items
- Climatic chambers — 2 calibration items
- Laboratory test sieves — 2 calibration items
- Electrical thermometers (with temperature recording) — 1 calibration item
- Furnaces — 1 calibration item
- Liquid thermostats — 1 calibration item
- Sieve baskets of woven wire cloth — 1 calibration item
- Steam sterilization chambers (autoclaves, Koch apparatus etc.) — 1 calibration item
- Thermohygrometers — 1 calibration item
- Thermostatic chambers — 1 calibration item
Calibration principles (7)
- Internal procedure; At permanent location (S) and outside of it (P) — 3 calibration items
- Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S) — 3 calibration items
- Internal procedure; At permanent location (S) — 2 calibration items
- Internal procedure; Measurement using a calliper; At permanent location (S) — 2 calibration items
- Internal procedure; Outside of permanent location (P) — 2 calibration items
- Internal procedure; Direct method; At permanent location (S) — 1 calibration item
- Internal procedure; Direct method; At permanent location (S) and outside of it (P) — 1 calibration item
Certificate information
- Issue date
- 17.03.2026
- Issue no.
- 19
- Certificate date
- 06.04.2020
- Accreditation cycle
- 21.05.2024 — 27.05.2028
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (14)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Laboratory test sieves | Calibration — Length 0,02 mm to 10 mm · CMC 3 μm 10 mm to 50 mm · CMC 50 μm 50 mm to 125 mm · CMC 110 μm Length |
Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S) | PLP-SL based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 | |
| 2 | Bar sieves | Calibration — Length 2,5 mm to 10 mm · CMC 3,0 μm 10 mm to 50 mm · CMC 50 μm Length |
Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S) | PLP-SL based on PN-EN 933-3:2012 | |
| 3 | Sieve baskets of woven wire cloth | Calibration — Length 0,02 mm to 0,5 mm · CMC 3 μm Length |
Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S) | PLP-SL based on PN-ISO 3310-1:2000 | |
| 4 | Laboratory test sieves | Calibration — Length 10 mm to 50 mm · CMC 50 μm 50 mm to 125 mm · CMC 110 μm Length |
Internal procedure; Measurement using a calliper; At permanent location (S) | PLP-SL based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 | |
| 5 | Bar sieves | Calibration — Length 10 mm to 50 mm · CMC 50 μm Length |
Internal procedure; Measurement using a calliper; At permanent location (S) | PLP-SL based on PN-EN 933-3:2012 | |
| 6 | Thermohygrometers | Calibration — Relative humidity temperature range 10 °C to 20 °C — 22 %rh to 98 %rh · CMC 2,5 %rh temperature range 20 °C to 40 °C — 20 %rh to 98 %rh · CMC 2,5 %rh temperature range 40 °C to 60 °C — 20 %rh to 80 %rh · CMC 2,5 %rh Relative humidity |
Internal procedure; Direct method; At permanent location (S) | PLP-RH | |
| 7 | Climatic chambers | Calibration — Relative humidity temperature range 10 °C to 20 °C — 22 %rh to 98 %rh · CMC 3,0%rh 1) temperature range 20 °C to 40 °C — 20 %rh to 98 %rh · CMC 3,0%rh 1) temperature range 40 °C to 60 °C — 20 %rh to 80 %rh · CMC 3,0%rh 1) Relative humidity |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | PLP-KK | |
| 8 | Climatic chambers Thermostatic chambers |
Calibration — Temperature (electrical thermometry) -80 °C to -25 °C · CMC 0,5 °C 1) -25 °C to 200 °C · CMC 0,15 °C 1) Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) and outside of it (P) | PLP-BRT, PLP-PRT | |
| 9 | Liquid thermostats | Calibration — Temperature (electrical thermometry) -25 °C to 200 °C · CMC 0,15 °C 1) Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) and outside of it (P) | PLP-LW | |
| 10 | Furnaces | Calibration — Temperature (electrical thermometry) 100 °C to 1100 °C · CMC 3,0 °C 1) Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) and outside of it (P) | PLP-PL | |
| 11 | Steam sterilization chambers (autoclaves, Koch apparatus etc.) | Calibration — Temperature (electrical thermometry) 60 °C to 140 °C · CMC 0,5 °C 1) Temperature (electrical thermometry) |
Internal procedure; Outside of permanent location (P) | PLP-AT | |
| 12 | Electrical thermometers (including electronic) | Calibration — Temperature (electrical thermometry) -95 °C to -25 °C · CMC 0,2 °C -25 °C to 80 °C · CMC 0,05 °C 80 °C to 200 °C · CMC 0,06 °C 200 ºC°C to 1100 °C · CMC 2,5 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | PLP-TE | |
| 13 | Electrical thermometers (including electronic) | Calibration — Temperature (electrical thermometry) -95 °C to 200 °C · CMC 0,2 °C 200 °C to 1000 °C · CMC 2,5 °C Temperature (electrical thermometry) |
Internal procedure; Outside of permanent location (P) | PLP-TE | |
| 14 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -40 °C to 60 °C · CMC 0,2 °C 60 °C to 140 °C · CMC 0,3 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | PLP-RT | |
Reference standards (13)
PLP-AT
PLP-BRT
PLP-KK
PLP-LW
PLP-PL
PLP-PRT
PLP-RH
PLP-RT
PLP-SL
PLP-TE
PN-EN 933-3:2012
PN-ISO 3310-1:2000
PN-ISO 3310-2:2000