{"lab":{"_id":"6af5747a0ecd48de0c70624f","accr_number":"AP 115","country":"PL","imported_at":"2026-11-11T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Kokoszycka 172 C, 44-300 Wodzisław Śląski","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"06.04.2020","city":"Wodzisław Śląski","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units.","cycle_from":"21.05.2024","cycle_to":"27.05.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"6.01","pl":"długość","en":"length","de":"Länge","zh":"长度","cs":"délka"},{"codes":"14.02","pl":"wilgotność","en":"humidity","de":"Feuchte","zh":"湿度","cs":"vlhkost"},{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"teplota (elektrická termometrie)"}],"has_en":true,"has_zh":true,"issue":{"no":"19","date":"17.03.2026"},"issue_date":"17.03.2026","issue_number":"19","lab_division":null,"lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[18.4456319,50.0165875]},"map_coord":[50.0165875,18.4456319],"map_geo":"nominatim-street","methods_count":14,"name":"POL-EKO Laboratorium Pomiarowe Sp. z o.o.","parse_date":"2026-11-11T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-11T12:00:00.000Z","pdf_files":["AP_115.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: długość, wilgotność, temperatura (termometria elektryczna). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"pol-eko laboratorium pomiarowe sp. z o.o. ul. kokoszycka 172 c, 44-300 wodzisław śląski laboratorium wzorcujące. wielkości mierzone: długość, wilgotność, temperatura (termometria elektryczna). w stałej lokalizacji (s) i/lub poza nią (p). ap 115 ap115 laboratorium wzorcujące wzorcowanie kalibracja length humidity temperature (electrical thermometry) pol-eko laboratorium pomiarowe sp. z o.o. ul. kokoszycka 172 c, 44-300 wodzislaw slaski laboratorium wzorcujace. wielkosci mierzone: dlugosc, wilgotnosc, temperatura (termometria elektryczna). w stalej lokalizacji (s) i/lub poza nia (p). ap 115 ap115 laboratorium wzorcujace wzorcowanie kalibracja length humidity temperature (electrical thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20115,podmiot.html","source_pdf_sha256":"bfae45bc461c970b1b1b9ae657b6818f7d24ae9fa39bd7cea9cb72feb1329018","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/11/b9d3b046d3d735de91fa4f916c9ca5cb/AP%20115.pdf","status":"active","updated_at":"2026-11-11T12:00:00.000Z","valid_from":"28-05-2008","valid_until":"27-05-2028","website":"www.polekolab.pl","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben.","has_de":true,"cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny.","has_cs":true,"pelny_cs":true},"methods":[{"_id":"0119b8f833f29d601f805b26","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Sita kontrolne laboratoryjne","test_object_en":"Laboratory test sieves","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,02 mm do 10 mm","cmc":"3 μm"},{"name":"","range":"10 mm do 50 mm","cmc":"50 μm"},{"name":"","range":"50 mm do 125 mm","cmc":"110 μm"}],"parameters_en":[{"name":"","range":"0,02 mm to 10 mm","cmc":"3 μm"},{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"},{"name":"","range":"50 mm to 125 mm","cmc":"110 μm"}],"technique":"Procedura wewnętrzna; Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Measurement using a coordinate measuring microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n0,02 mm do 10 mm CMC 3 μm\n10 mm do 50 mm CMC 50 μm\n50 mm do 125 mm CMC 110 μm\nProcedura wewnętrzna; Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego; W stałej lokalizacji (S)","reference":"PLP-SL w oparciu o PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","norm_bases":["PLP-SL","PN-ISO 3310-1:2000","PN-ISO 3310-2:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sita kontrolne laboratoryjne Wzorcowanie — Długość\nZakres:\n0,02 mm do 10 mm CMC 3 μm\n10 mm do 50 mm CMC 50 μm\n50 mm do 125 mm CMC 110 μm\nProcedura wewnętrzna; Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego; W stałej lokalizacji (S) PLP-SL w oparciu o PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 Sita kontrolne laboratoryjne Wzorcowanie — Dlugosc\nZakres:\n0,02 mm do 10 mm CMC 3 μm\n10 mm do 50 mm CMC 50 μm\n50 mm do 125 mm CMC 110 μm\nProcedura wewnetrzna; Pomiar za pomoca wspolrzednosciowego mikroskopu pomiarowego; W stalej lokalizacji (S) PLP-SL w oparciu o PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","search_en":"Laboratory test sieves Calibration — Length Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S) Length Internal procedure Measurement using a coordinate measuring microscope At permanent location (S) PLP-SL based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PLP-SL based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,02 mm to 10 mm","cmc":"3 μm"},{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"},{"name":"","range":"50 mm to 125 mm","cmc":"110 μm"}],"reference_de":"PLP-SL auf Grundlage von PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","regulatory_area_de":"Länge","search_de":"Laborprüfsiebe Kalibrierung — Länge Interne Verfahrensanweisung; Messung mit einem Koordinatenmessmikroskop; Am festen Standort (S) Länge Internes Verfahren Messung mit einem Koordinatenmessmikroskop Am festen Standort (S) PLP-SL auf Grundlage von PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","technique_de":"Interne Verfahrensanweisung; Messung mit einem Koordinatenmessmikroskop; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung mit einem Koordinatenmessmikroskop","Am festen Standort (S)"],"test_object_de":"Laborprüfsiebe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,02 mm to 10 mm","cmc":"3 μm"},{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"},{"name":"","range":"50 mm to 125 mm","cmc":"110 μm"}],"reference_zh":"PLP-SL，依据 PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","regulatory_area_zh":"长度","search_zh":"实验室试验筛 校准 — 长度 内部程序；使用坐标测量显微镜测量；在固定地点 (S) 长度 内部程序 使用坐标测量显微镜测量 在固定地点 (S) PLP-SL，依据 PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","technique_zh":"内部程序；使用坐标测量显微镜测量；在固定地点 (S)","techniques_zh":["内部程序","使用坐标测量显微镜测量","在固定地点 (S)"],"test_object_zh":"实验室试验筛","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,02 mm to 10 mm","cmc":"3 μm"},{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"},{"name":"","range":"50 mm to 125 mm","cmc":"110 μm"}],"reference_cs":"PLP-SL na základě PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","regulatory_area_cs":"Délka","search_cs":"Laboratorní zkušební síta Kalibrace — Délka Vnitřní postup; Měření pomocí souřadnicového měřicího mikroskopu; Ve stálé lokalitě (S) Délka Vnitřní postup Měření pomocí souřadnicového měřicího mikroskopu Ve stálé lokalitě (S) PLP-SL na základě PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","technique_cs":"Vnitřní postup; Měření pomocí souřadnicového měřicího mikroskopu; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Měření pomocí souřadnicového měřicího mikroskopu","Ve stálé lokalitě (S)"],"test_object_cs":"Laboratorní zkušební síta"},{"_id":"02e91adfab5d00faaed8da9f","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Sita prętowe","test_object_en":"Bar sieves","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"2,5 mm do 10 mm","cmc":"3,0 μm"},{"name":"","range":"10 mm do 50 mm","cmc":"50 μm"}],"parameters_en":[{"name":"","range":"2,5 mm to 10 mm","cmc":"3,0 μm"},{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"}],"technique":"Procedura wewnętrzna; Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Measurement using a coordinate measuring microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n2,5 mm do 10 mm CMC 3,0 μm\n10 mm do 50 mm CMC 50 μm\nProcedura wewnętrzna; Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego; W stałej lokalizacji (S)","reference":"PLP-SL w oparciu o PN-EN 933-3:2012","norm_bases":["PLP-SL","PN-EN 933-3:2012"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sita prętowe Wzorcowanie — Długość\nZakres:\n2,5 mm do 10 mm CMC 3,0 μm\n10 mm do 50 mm CMC 50 μm\nProcedura wewnętrzna; Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego; W stałej lokalizacji (S) PLP-SL w oparciu o PN-EN 933-3:2012 Sita pretowe Wzorcowanie — Dlugosc\nZakres:\n2,5 mm do 10 mm CMC 3,0 μm\n10 mm do 50 mm CMC 50 μm\nProcedura wewnetrzna; Pomiar za pomoca wspolrzednosciowego mikroskopu pomiarowego; W stalej lokalizacji (S) PLP-SL w oparciu o PN-EN 933-3:2012","search_en":"Bar sieves Calibration — Length Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S) Length Internal procedure Measurement using a coordinate measuring microscope At permanent location (S) PLP-SL based on PN-EN 933-3:2012","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PLP-SL based on PN-EN 933-3:2012","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"2,5 mm to 10 mm","cmc":"3,0 μm"},{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"}],"reference_de":"PLP-SL auf Grundlage von PN-EN 933-3:2012","regulatory_area_de":"Länge","search_de":"Stabsiebe Kalibrierung — Länge Interne Verfahrensanweisung; Messung mit einem Koordinatenmessmikroskop; Am festen Standort (S) Länge Internes Verfahren Messung mit einem Koordinatenmessmikroskop Am festen Standort (S) PLP-SL auf Grundlage von PN-EN 933-3:2012","technique_de":"Interne Verfahrensanweisung; Messung mit einem Koordinatenmessmikroskop; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung mit einem Koordinatenmessmikroskop","Am festen Standort (S)"],"test_object_de":"Stabsiebe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"2,5 mm to 10 mm","cmc":"3,0 μm"},{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"}],"reference_zh":"PLP-SL，依据 PN-EN 933-3:2012","regulatory_area_zh":"长度","search_zh":"棒条筛 校准 — 长度 内部程序；使用坐标测量显微镜测量；在固定地点 (S) 长度 内部程序 使用坐标测量显微镜测量 在固定地点 (S) PLP-SL，依据 PN-EN 933-3:2012","technique_zh":"内部程序；使用坐标测量显微镜测量；在固定地点 (S)","techniques_zh":["内部程序","使用坐标测量显微镜测量","在固定地点 (S)"],"test_object_zh":"棒条筛","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"2,5 mm to 10 mm","cmc":"3,0 μm"},{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"}],"reference_cs":"PLP-SL na základě PN-EN 933-3:2012","regulatory_area_cs":"Délka","search_cs":"Tyčová síta Kalibrace — Délka Vnitřní postup; Měření pomocí souřadnicového měřicího mikroskopu; Ve stálé lokalitě (S) Délka Vnitřní postup Měření pomocí souřadnicového měřicího mikroskopu Ve stálé lokalitě (S) PLP-SL na základě PN-EN 933-3:2012","technique_cs":"Vnitřní postup; Měření pomocí souřadnicového měřicího mikroskopu; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Měření pomocí souřadnicového měřicího mikroskopu","Ve stálé lokalitě (S)"],"test_object_cs":"Tyčová síta"},{"_id":"11b7d1f3ab3ef5c9ed99bea1","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Sita kosz z tkaniny z drutu","test_object_en":"Sieve baskets of woven wire cloth","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"0,02 mm do 0,5 mm","cmc":"3 μm"}],"parameters_en":[{"name":"","range":"0,02 mm to 0,5 mm","cmc":"3 μm"}],"technique":"Procedura wewnętrzna; Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S)","techniques":["Procedura wewnętrzna","Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Measurement using a coordinate measuring microscope","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n0,02 mm do 0,5 mm CMC 3 μm\nProcedura wewnętrzna; Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego; W stałej lokalizacji (S)","reference":"PLP-SL w oparciu o PN-ISO 3310-1:2000","norm_bases":["PLP-SL","PN-ISO 3310-1:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sita kosz z tkaniny z drutu Wzorcowanie — Długość\n0,02 mm do 0,5 mm CMC 3 μm\nProcedura wewnętrzna; Pomiar za pomocą współrzędnościowego mikroskopu pomiarowego; W stałej lokalizacji (S) PLP-SL w oparciu o PN-ISO 3310-1:2000 Sita kosz z tkaniny z drutu Wzorcowanie — Dlugosc\n0,02 mm do 0,5 mm CMC 3 μm\nProcedura wewnetrzna; Pomiar za pomoca wspolrzednosciowego mikroskopu pomiarowego; W stalej lokalizacji (S) PLP-SL w oparciu o PN-ISO 3310-1:2000","search_en":"Sieve baskets of woven wire cloth Calibration — Length Internal procedure; Measurement using a coordinate measuring microscope; At permanent location (S) Length Internal procedure Measurement using a coordinate measuring microscope At permanent location (S) PLP-SL based on PN-ISO 3310-1:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PLP-SL based on PN-ISO 3310-1:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"0,02 mm to 0,5 mm","cmc":"3 μm"}],"reference_de":"PLP-SL auf Grundlage von PN-ISO 3310-1:2000","regulatory_area_de":"Länge","search_de":"Siebkörbe aus Drahtgewebe Kalibrierung — Länge Interne Verfahrensanweisung; Messung mit einem Koordinatenmessmikroskop; Am festen Standort (S) Länge Internes Verfahren Messung mit einem Koordinatenmessmikroskop Am festen Standort (S) PLP-SL auf Grundlage von PN-ISO 3310-1:2000","technique_de":"Interne Verfahrensanweisung; Messung mit einem Koordinatenmessmikroskop; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung mit einem Koordinatenmessmikroskop","Am festen Standort (S)"],"test_object_de":"Siebkörbe aus Drahtgewebe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"0,02 mm to 0,5 mm","cmc":"3 μm"}],"reference_zh":"PLP-SL，依据 PN-ISO 3310-1:2000","regulatory_area_zh":"长度","search_zh":"金属丝编织网筛篮 校准 — 长度 内部程序；使用坐标测量显微镜测量；在固定地点 (S) 长度 内部程序 使用坐标测量显微镜测量 在固定地点 (S) PLP-SL，依据 PN-ISO 3310-1:2000","technique_zh":"内部程序；使用坐标测量显微镜测量；在固定地点 (S)","techniques_zh":["内部程序","使用坐标测量显微镜测量","在固定地点 (S)"],"test_object_zh":"金属丝编织网筛篮","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"0,02 mm to 0,5 mm","cmc":"3 μm"}],"reference_cs":"PLP-SL na základě PN-ISO 3310-1:2000","regulatory_area_cs":"Délka","search_cs":"Sítové koše z drátěné tkaniny Kalibrace — Délka Vnitřní postup; Měření pomocí souřadnicového měřicího mikroskopu; Ve stálé lokalitě (S) Délka Vnitřní postup Měření pomocí souřadnicového měřicího mikroskopu Ve stálé lokalitě (S) PLP-SL na základě PN-ISO 3310-1:2000","technique_cs":"Vnitřní postup; Měření pomocí souřadnicového měřicího mikroskopu; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Měření pomocí souřadnicového měřicího mikroskopu","Ve stálé lokalitě (S)"],"test_object_cs":"Sítové koše z drátěné tkaniny"},{"_id":"d62ef2a49563780feeb18bdf","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Sita kontrolne laboratoryjne","test_object_en":"Laboratory test sieves","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 50 mm","cmc":"50 μm"},{"name":"","range":"50 mm do 125 mm","cmc":"110 μm"}],"parameters_en":[{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"},{"name":"","range":"50 mm to 125 mm","cmc":"110 μm"}],"technique":"Procedura wewnętrzna; Pomiar za pomocą suwmiarki; W stałej lokalizacji (S)","technique_en":"Internal procedure; Measurement using a calliper; At permanent location (S)","techniques":["Procedura wewnętrzna","Pomiar za pomocą suwmiarki","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Measurement using a calliper","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\nZakres:\n10 mm do 50 mm CMC 50 μm\n50 mm do 125 mm CMC 110 μm\nProcedura wewnętrzna; Pomiar za pomocą suwmiarki; W stałej lokalizacji (S)","reference":"PLP-SL w oparciu o PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","norm_bases":["PLP-SL","PN-ISO 3310-1:2000","PN-ISO 3310-2:2000"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sita kontrolne laboratoryjne Wzorcowanie — Długość\nZakres:\n10 mm do 50 mm CMC 50 μm\n50 mm do 125 mm CMC 110 μm\nProcedura wewnętrzna; Pomiar za pomocą suwmiarki; W stałej lokalizacji (S) PLP-SL w oparciu o PN-ISO 3310-1:2000 PN-ISO 3310-2:2000 Sita kontrolne laboratoryjne Wzorcowanie — Dlugosc\nZakres:\n10 mm do 50 mm CMC 50 μm\n50 mm do 125 mm CMC 110 μm\nProcedura wewnetrzna; Pomiar za pomoca suwmiarki; W stalej lokalizacji (S) PLP-SL w oparciu o PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","search_en":"Laboratory test sieves Calibration — Length Internal procedure; Measurement using a calliper; At permanent location (S) Length Internal procedure Measurement using a calliper At permanent location (S) PLP-SL based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PLP-SL based on PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"},{"name":"","range":"50 mm to 125 mm","cmc":"110 μm"}],"reference_de":"PLP-SL auf Grundlage von PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","regulatory_area_de":"Länge","search_de":"Laborprüfsiebe Kalibrierung — Länge Interne Verfahrensanweisung; Messung mit dem Messschieber; Am festen Standort (S) Länge Internes Verfahren Messung mit Messschieber Am festen Standort (S) PLP-SL auf Grundlage von PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","technique_de":"Interne Verfahrensanweisung; Messung mit dem Messschieber; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung mit Messschieber","Am festen Standort (S)"],"test_object_de":"Laborprüfsiebe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"},{"name":"","range":"50 mm to 125 mm","cmc":"110 μm"}],"reference_zh":"PLP-SL，依据 PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","regulatory_area_zh":"长度","search_zh":"实验室试验筛 校准 — 长度 内部程序；使用游标卡尺测量；在固定地点 (S) 长度 内部程序 使用游标卡尺测量 在固定地点 (S) PLP-SL，依据 PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","technique_zh":"内部程序；使用游标卡尺测量；在固定地点 (S)","techniques_zh":["内部程序","使用游标卡尺测量","在固定地点 (S)"],"test_object_zh":"实验室试验筛","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"},{"name":"","range":"50 mm to 125 mm","cmc":"110 μm"}],"reference_cs":"PLP-SL na základě PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","regulatory_area_cs":"Délka","search_cs":"Laboratorní zkušební síta Kalibrace — Délka Vnitřní postup; Měření pomocí posuvného měřidla; Ve stálé lokalitě (S) Délka Vnitřní postup Měření pomocí posuvného měřidla Ve stálé lokalitě (S) PLP-SL na základě PN-ISO 3310-1:2000 PN-ISO 3310-2:2000","technique_cs":"Vnitřní postup; Měření pomocí posuvného měřidla; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Měření pomocí posuvného měřidla","Ve stálé lokalitě (S)"],"test_object_cs":"Laboratorní zkušební síta"},{"_id":"690bd518ad22ec2edfa8d71d","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Sita prętowe","test_object_en":"Bar sieves","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"10 mm do 50 mm","cmc":"50 μm"}],"parameters_en":[{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"}],"technique":"Procedura wewnętrzna; Pomiar za pomocą suwmiarki; W stałej lokalizacji (S)","technique_en":"Internal procedure; Measurement using a calliper; At permanent location (S)","techniques":["Procedura wewnętrzna","Pomiar za pomocą suwmiarki","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Measurement using a calliper","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n10 mm do 50 mm CMC 50 μm\nProcedura wewnętrzna; Pomiar za pomocą suwmiarki; W stałej lokalizacji (S)","reference":"PLP-SL w oparciu o PN-EN 933-3:2012","norm_bases":["PLP-SL","PN-EN 933-3:2012"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Sita prętowe Wzorcowanie — Długość\n10 mm do 50 mm CMC 50 μm\nProcedura wewnętrzna; Pomiar za pomocą suwmiarki; W stałej lokalizacji (S) PLP-SL w oparciu o PN-EN 933-3:2012 Sita pretowe Wzorcowanie — Dlugosc\n10 mm do 50 mm CMC 50 μm\nProcedura wewnetrzna; Pomiar za pomoca suwmiarki; W stalej lokalizacji (S) PLP-SL w oparciu o PN-EN 933-3:2012","search_en":"Bar sieves Calibration — Length Internal procedure; Measurement using a calliper; At permanent location (S) Length Internal procedure Measurement using a calliper At permanent location (S) PLP-SL based on PN-EN 933-3:2012","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PLP-SL based on PN-EN 933-3:2012","methodology_de":"Kalibrierung — Länge","parameters_de":[{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"}],"reference_de":"PLP-SL auf Grundlage von PN-EN 933-3:2012","regulatory_area_de":"Länge","search_de":"Stabsiebe Kalibrierung — Länge Interne Verfahrensanweisung; Messung mit dem Messschieber; Am festen Standort (S) Länge Internes Verfahren Messung mit Messschieber Am festen Standort (S) PLP-SL auf Grundlage von PN-EN 933-3:2012","technique_de":"Interne Verfahrensanweisung; Messung mit dem Messschieber; Am festen Standort (S)","techniques_de":["Internes Verfahren","Messung mit Messschieber","Am festen Standort (S)"],"test_object_de":"Stabsiebe","methodology_zh":"校准 — 长度","parameters_zh":[{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"}],"reference_zh":"PLP-SL，依据 PN-EN 933-3:2012","regulatory_area_zh":"长度","search_zh":"棒条筛 校准 — 长度 内部程序；使用游标卡尺测量；在固定地点 (S) 长度 内部程序 使用游标卡尺测量 在固定地点 (S) PLP-SL，依据 PN-EN 933-3:2012","technique_zh":"内部程序；使用游标卡尺测量；在固定地点 (S)","techniques_zh":["内部程序","使用游标卡尺测量","在固定地点 (S)"],"test_object_zh":"棒条筛","methodology_cs":"Kalibrace — Délka","parameters_cs":[{"name":"","range":"10 mm to 50 mm","cmc":"50 μm"}],"reference_cs":"PLP-SL na základě PN-EN 933-3:2012","regulatory_area_cs":"Délka","search_cs":"Tyčová síta Kalibrace — Délka Vnitřní postup; Měření pomocí posuvného měřidla; Ve stálé lokalitě (S) Délka Vnitřní postup Měření pomocí posuvného měřidla Ve stálé lokalitě (S) PLP-SL na základě PN-EN 933-3:2012","technique_cs":"Vnitřní postup; Měření pomocí posuvného měřidla; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Měření pomocí posuvného měřidla","Ve stálé lokalitě (S)"],"test_object_cs":"Tyčová síta"},{"_id":"dccea1f247f2ee43ec09d099","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Termohigrometry","test_object_en":"Thermohygrometers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 10 °C do 20 °C","range":"22 %rh do 98 %rh","cmc":"2,5 %rh"},{"name":"zakres temperatur 20 °C do 40 °C","range":"20 %rh do 98 %rh","cmc":"2,5 %rh"},{"name":"zakres temperatur 40 °C do 60 °C","range":"20 %rh do 80 %rh","cmc":"2,5 %rh"}],"parameters_en":[{"name":"temperature range 10 °C to 20 °C","range":"22 %rh to 98 %rh","cmc":"2,5 %rh"},{"name":"temperature range 20 °C to 40 °C","range":"20 %rh to 98 %rh","cmc":"2,5 %rh"},{"name":"temperature range 40 °C to 60 °C","range":"20 %rh to 80 %rh","cmc":"2,5 %rh"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nZakres:\nzakres temperatur 10 °C do 20 °C 22 %rh do 98 %rh CMC 2,5 %rh\nzakres temperatur 20 °C do 40 °C 20 %rh do 98 %rh CMC 2,5 %rh\nzakres temperatur 40 °C do 60 °C 20 %rh do 80 %rh CMC 2,5 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PLP-RH","norm_bases":["PLP-RH"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termohigrometry Wzorcowanie — Wilgotność względna\nZakres:\nzakres temperatur 10 °C do 20 °C 22 %rh do 98 %rh CMC 2,5 %rh\nzakres temperatur 20 °C do 40 °C 20 %rh do 98 %rh CMC 2,5 %rh\nzakres temperatur 40 °C do 60 °C 20 %rh do 80 %rh CMC 2,5 %rh\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PLP-RH Termohigrometry Wzorcowanie — Wilgotnosc wzgledna\nZakres:\nzakres temperatur 10 °C do 20 °C 22 %rh do 98 %rh CMC 2,5 %rh\nzakres temperatur 20 °C do 40 °C 20 %rh do 98 %rh CMC 2,5 %rh\nzakres temperatur 40 °C do 60 °C 20 %rh do 80 %rh CMC 2,5 %rh\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PLP-RH","search_en":"Thermohygrometers Calibration — Relative humidity Internal procedure; Direct method; At permanent location (S) Relative humidity Internal procedure Direct method At permanent location (S) temperature range 10 °C to 20 °C temperature range 20 °C to 40 °C temperature range 40 °C to 60 °C PLP-RH","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperaturbereich 10 °C bis 20 °C","range":"22 %rh to 98 %rh","cmc":"2,5 %rh"},{"name":"Temperaturbereich 20 °C bis 40 °C","range":"20 %rh bis 98 %rh","cmc":"2,5 %rh"},{"name":"Temperaturbereich 40 °C bis 60 °C","range":"20 %rh bis 80 %rh","cmc":"2,5 %rh"}],"regulatory_area_de":"Relative Feuchte","search_de":"Thermohygrometer Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) Relative Feuchte Internes Verfahren Direktes Verfahren Am festen Standort (S) Temperaturbereich 10 °C bis 20 °C Temperaturbereich 20 °C bis 40 °C Temperaturbereich 40 °C bis 60 °C PLP-RH","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Thermohygrometer","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 10 °C 至 20 °C","range":"22 %rh to 98 %rh","cmc":"2,5 %rh"},{"name":"温度范围 20 °C 至 40 °C","range":"20 %rh 至 98 %rh","cmc":"2,5 %rh"},{"name":"温度范围 40 °C 至 60 °C","range":"20 %rh 至 80 %rh","cmc":"2,5 %rh"}],"regulatory_area_zh":"相对湿度","search_zh":"温湿度计 校准 — 相对湿度 内部程序；直接法；在固定地点 (S) 相对湿度 内部程序 直接法 在固定地点 (S) 温度范围 10 °C 至 20 °C 温度范围 20 °C 至 40 °C 温度范围 40 °C 至 60 °C PLP-RH","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"温湿度计","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"rozsah teplot 10 °C až 20 °C","range":"22 %rh to 98 %rh","cmc":"2,5 %rh"},{"name":"rozsah teplot 20 °C až 40 °C","range":"20 %rh do 98 %rh","cmc":"2,5 %rh"},{"name":"rozsah teplot 40 °C až 60 °C","range":"20 %rh do 80 %rh","cmc":"2,5 %rh"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Termohygrometry Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Relativní vlhkost Vnitřní postup Přímá metoda Ve stálé lokalitě (S) rozsah teplot 10 °C až 20 °C rozsah teplot 20 °C až 40 °C rozsah teplot 40 °C až 60 °C PLP-RH","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Termohygrometry"},{"_id":"9f05af9e5f70f5f38652bc4e","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Komory klimatyczne","test_object_en":"Climatic chambers","methodology":"Wzorcowanie — Wilgotność względna","methodology_en":"Calibration — Relative humidity","parameters":[{"name":"zakres temperatur 10 °C do 20 °C","range":"22 %rh do 98 %rh","cmc":"3,0%rh 1)"},{"name":"zakres temperatur 20 °C do 40 °C","range":"20 %rh do 98 %rh","cmc":"3,0%rh 1)"},{"name":"zakres temperatur 40 °C do 60 °C","range":"20 %rh do 80 %rh","cmc":"3,0%rh 1)"}],"parameters_en":[{"name":"temperature range 10 °C to 20 °C","range":"22 %rh to 98 %rh","cmc":"3,0%rh 1)"},{"name":"temperature range 20 °C to 40 °C","range":"20 %rh to 98 %rh","cmc":"3,0%rh 1)"},{"name":"temperature range 40 °C to 60 °C","range":"20 %rh to 80 %rh","cmc":"3,0%rh 1)"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wilgotność względna\nZakres:\nzakres temperatur 10 °C do 20 °C 22 %rh do 98 %rh CMC 3,0%rh 1)\nzakres temperatur 20 °C do 40 °C 20 %rh do 98 %rh CMC 3,0%rh 1)\nzakres temperatur 40 °C do 60 °C 20 %rh do 80 %rh CMC 3,0%rh 1)\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"PLP-KK","norm_bases":["PLP-KK"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wilgotność względna","regulatory_area_en":"Relative humidity","outside_premises":true,"location_of_activity":"S, P","note":"1) Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"1) The CMC uncertainty value refers to a single measurement point in the space of the device","search_text":"Komory klimatyczne Wzorcowanie — Wilgotność względna\nZakres:\nzakres temperatur 10 °C do 20 °C 22 %rh do 98 %rh CMC 3,0%rh 1)\nzakres temperatur 20 °C do 40 °C 20 %rh do 98 %rh CMC 3,0%rh 1)\nzakres temperatur 40 °C do 60 °C 20 %rh do 80 %rh CMC 3,0%rh 1)\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) i poza nią (P) PLP-KK Komory klimatyczne Wzorcowanie — Wilgotnosc wzgledna\nZakres:\nzakres temperatur 10 °C do 20 °C 22 %rh do 98 %rh CMC 3,0%rh 1)\nzakres temperatur 20 °C do 40 °C 20 %rh do 98 %rh CMC 3,0%rh 1)\nzakres temperatur 40 °C do 60 °C 20 %rh do 80 %rh CMC 3,0%rh 1)\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) i poza nia (P) PLP-KK","search_en":"Climatic chambers Calibration — Relative humidity Internal procedure; Direct method; At permanent location (S) and outside of it (P) Relative humidity Internal procedure Direct method At permanent location (S) and outside of it (P) temperature range 10 °C to 20 °C temperature range 20 °C to 40 °C temperature range 40 °C to 60 °C PLP-KK","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Relative Feuchte","parameters_de":[{"name":"Temperaturbereich 10 °C bis 20 °C","range":"22 %rh to 98 %rh","cmc":"3,0%rh 1)"},{"name":"Temperaturbereich 20 °C bis 40 °C","range":"20 %rh bis 98 %rh","cmc":"3,0%rh 1)"},{"name":"Temperaturbereich 40 °C bis 60 °C","range":"20 %rh bis 80 %rh","cmc":"3,0%rh 1)"}],"regulatory_area_de":"Relative Feuchte","search_de":"Klimakammern Kalibrierung — Relative Feuchte Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P) Relative Feuchte Internes Verfahren Direktes Verfahren Am festen Standort (S) und außerhalb (P) Temperaturbereich 10 °C bis 20 °C Temperaturbereich 20 °C bis 40 °C Temperaturbereich 40 °C bis 60 °C PLP-KK","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Klimakammern","methodology_zh":"校准 — 相对湿度","parameters_zh":[{"name":"温度范围 10 °C 至 20 °C","range":"22 %rh to 98 %rh","cmc":"3,0%rh 1)"},{"name":"温度范围 20 °C 至 40 °C","range":"20 %rh 至 98 %rh","cmc":"3,0%rh 1)"},{"name":"温度范围 40 °C 至 60 °C","range":"20 %rh 至 80 %rh","cmc":"3,0%rh 1)"}],"regulatory_area_zh":"相对湿度","search_zh":"气候箱 校准 — 相对湿度 内部程序；直接法；在固定地点 (S) 及固定地点以外 (P) 相对湿度 内部程序 直接法 在固定地点 (S) 及固定地点以外 (P) 温度范围 10 °C 至 20 °C 温度范围 20 °C 至 40 °C 温度范围 40 °C 至 60 °C PLP-KK","technique_zh":"内部程序；直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"气候箱","methodology_cs":"Kalibrace — Relativní vlhkost","parameters_cs":[{"name":"rozsah teplot 10 °C až 20 °C","range":"22 %rh to 98 %rh","cmc":"3,0%rh 1)"},{"name":"rozsah teplot 20 °C až 40 °C","range":"20 %rh do 98 %rh","cmc":"3,0%rh 1)"},{"name":"rozsah teplot 40 °C až 60 °C","range":"20 %rh do 80 %rh","cmc":"3,0%rh 1)"}],"regulatory_area_cs":"Relativní vlhkost","search_cs":"Klimatické komory Kalibrace — Relativní vlhkost Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P) Relativní vlhkost Vnitřní postup Přímá metoda V trvalé lokalitě (S) i mimo ni (P) rozsah teplot 10 °C až 20 °C rozsah teplot 20 °C až 40 °C rozsah teplot 40 °C až 60 °C PLP-KK","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","Přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Klimatické komory"},{"_id":"6d79a3ec77b245a652addeeb","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Komory klimatyczne\nKomory termostatyczne","test_object_en":"Climatic chambers\nThermostatic chambers","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-80 °C do -25 °C","cmc":"0,5 °C 1)"},{"name":"","range":"-25 °C do 200 °C","cmc":"0,15 °C 1)"}],"parameters_en":[{"name":"","range":"-80 °C to -25 °C","cmc":"0,5 °C 1)"},{"name":"","range":"-25 °C to 200 °C","cmc":"0,15 °C 1)"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -25 °C CMC 0,5 °C 1)\n-25 °C do 200 °C CMC 0,15 °C 1)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PLP-BRT, PLP-PRT","norm_bases":["PLP-BRT","PLP-PRT"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":"1) Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"1) The CMC uncertainty value refers to a single measurement point in the space of the device","search_text":"Komory klimatyczne\nKomory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -25 °C CMC 0,5 °C 1)\n-25 °C do 200 °C CMC 0,15 °C 1)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PLP-BRT, PLP-PRT Komory klimatyczne\nKomory termostatyczne Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-80 °C do -25 °C CMC 0,5 °C 1)\n-25 °C do 200 °C CMC 0,15 °C 1)\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PLP-BRT, PLP-PRT","search_en":"Climatic chambers Thermostatic chambers Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure At permanent location (S) and outside of it (P) PLP-BRT, PLP-PRT","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-80 °C to -25 °C","cmc":"0,5 °C 1)"},{"name":"","range":"-25 °C to 200 °C","cmc":"0,15 °C 1)"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Klimakammern Thermostatkammern Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) und außerhalb (P) PLP-BRT, PLP-PRT","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Klimakammern\nThermostatkammern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-80 °C to -25 °C","cmc":"0,5 °C 1)"},{"name":"","range":"-25 °C to 200 °C","cmc":"0,15 °C 1)"}],"regulatory_area_zh":"温度（电测温）","search_zh":"气候箱 恒温箱 校准 — 温度（电测温） 内部程序；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 在固定地点 (S) 及固定地点以外 (P) PLP-BRT, PLP-PRT","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"气候箱\n恒温箱","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-80 °C to -25 °C","cmc":"0,5 °C 1)"},{"name":"","range":"-25 °C to 200 °C","cmc":"0,15 °C 1)"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Klimatické komory Termostatické komory Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) PLP-BRT, PLP-PRT","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Klimatické komory\nTermostatické komory"},{"_id":"69e414f2e542879d549d08a1","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Termostaty cieczowe","test_object_en":"Liquid thermostats","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-25 °C do 200 °C","cmc":"0,15 °C 1)"}],"parameters_en":[{"name":"","range":"-25 °C to 200 °C","cmc":"0,15 °C 1)"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n-25 °C do 200 °C CMC 0,15 °C 1)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PLP-LW","norm_bases":["PLP-LW"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":"1) Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"1) The CMC uncertainty value refers to a single measurement point in the space of the device","search_text":"Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-25 °C do 200 °C CMC 0,15 °C 1)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PLP-LW Termostaty cieczowe Wzorcowanie — Temperatura (termometria elektryczna)\n-25 °C do 200 °C CMC 0,15 °C 1)\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PLP-LW","search_en":"Liquid thermostats Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure At permanent location (S) and outside of it (P) PLP-LW","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-25 °C to 200 °C","cmc":"0,15 °C 1)"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Flüssigkeitsthermostate Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) und außerhalb (P) PLP-LW","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Flüssigkeitsthermostate","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-25 °C to 200 °C","cmc":"0,15 °C 1)"}],"regulatory_area_zh":"温度（电测温）","search_zh":"液体恒温槽 校准 — 温度（电测温） 内部程序；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 在固定地点 (S) 及固定地点以外 (P) PLP-LW","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"液体恒温槽","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-25 °C to 200 °C","cmc":"0,15 °C 1)"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kapalinové termostaty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) PLP-LW","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Kapalinové termostaty"},{"_id":"a74fb9961315080523f049b8","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Piece","test_object_en":"Furnaces","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"100 °C do 1100 °C","cmc":"3,0 °C 1)"}],"parameters_en":[{"name":"","range":"100 °C to 1100 °C","cmc":"3,0 °C 1)"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n100 °C do 1100 °C CMC 3,0 °C 1)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PLP-PL","norm_bases":["PLP-PL"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"S, P","note":"1) Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"1) The CMC uncertainty value refers to a single measurement point in the space of the device","search_text":"Piece Wzorcowanie — Temperatura (termometria elektryczna)\n100 °C do 1100 °C CMC 3,0 °C 1)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PLP-PL Piece Wzorcowanie — Temperatura (termometria elektryczna)\n100 °C do 1100 °C CMC 3,0 °C 1)\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PLP-PL","search_en":"Furnaces Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) and outside of it (P) Temperature (electrical thermometry) Internal procedure At permanent location (S) and outside of it (P) PLP-PL","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"100 °C to 1100 °C","cmc":"3,0 °C 1)"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Öfen Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) und außerhalb (P) PLP-PL","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Öfen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"100 °C to 1100 °C","cmc":"3,0 °C 1)"}],"regulatory_area_zh":"温度（电测温）","search_zh":"炉具 校准 — 温度（电测温） 内部程序；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 在固定地点 (S) 及固定地点以外 (P) PLP-PL","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"炉具","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"100 °C to 1100 °C","cmc":"3,0 °C 1)"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Pece Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) PLP-PL","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Pece"},{"_id":"468f8392e9643e7de3724200","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Komory do sterylizacji parowej (autoklawy, aparaty Kocha itp.)","test_object_en":"Steam sterilization chambers (autoclaves, Koch apparatus etc.)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"60 °C do 140 °C","cmc":"0,5 °C 1)"}],"parameters_en":[{"name":"","range":"60 °C to 140 °C","cmc":"0,5 °C 1)"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\n60 °C do 140 °C CMC 0,5 °C 1)\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PLP-AT","norm_bases":["PLP-AT"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":"1) Wartość niepewności pomiaru dla CMC dotyczy pojedynczego punktu pomiarowego w przestrzeni urządzenia","note_en":"1) The CMC uncertainty value refers to a single measurement point in the space of the device","search_text":"Komory do sterylizacji parowej (autoklawy, aparaty Kocha itp.) Wzorcowanie — Temperatura (termometria elektryczna)\n60 °C do 140 °C CMC 0,5 °C 1)\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PLP-AT Komory do sterylizacji parowej (autoklawy, aparaty Kocha itp.) Wzorcowanie — Temperatura (termometria elektryczna)\n60 °C do 140 °C CMC 0,5 °C 1)\nProcedura wewnetrzna; Poza stala lokalizacja (P) PLP-AT","search_en":"Steam sterilization chambers (autoclaves, Koch apparatus etc.) Calibration — Temperature (electrical thermometry) Internal procedure; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Outside of permanent location (P) PLP-AT","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"60 °C to 140 °C","cmc":"0,5 °C 1)"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Dampfsterilisationskammern (Autoklaven, Koch-Apparate usw.) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Außerhalb des festen Standorts (P) PLP-AT","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Dampfsterilisationskammern (Autoklaven, Koch-Apparate usw.)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"60 °C to 140 °C","cmc":"0,5 °C 1)"}],"regulatory_area_zh":"温度（电测温）","search_zh":"蒸汽灭菌室（高压灭菌器、柯赫灭菌器等） 校准 — 温度（电测温） 内部程序；固定地点以外 (P) 温度（电测温） 内部程序 固定地点以外 (P) PLP-AT","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"蒸汽灭菌室（高压灭菌器、柯赫灭菌器等）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"60 °C to 140 °C","cmc":"0,5 °C 1)"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Komory pro parní sterilizaci (autoklávy, Kochovy přístroje apod.) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Mimo stálé pracoviště (P) Teplota (elektrická termometrie) Vnitřní postup Mimo stálou lokalitu (P) PLP-AT","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Komory pro parní sterilizaci (autoklávy, Kochovy přístroje apod.)"},{"_id":"2d23b58cd9e375d6bfbb7d64","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)","test_object_en":"Electrical thermometers (including electronic)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-95 °C do -25 °C","cmc":"0,2 °C"},{"name":"","range":"-25 °C do 80 °C","cmc":"0,05 °C"},{"name":"","range":"80 °C do 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 ºC°C do 1100 °C","cmc":"2,5 °C"}],"parameters_en":[{"name":"","range":"-95 °C to -25 °C","cmc":"0,2 °C"},{"name":"","range":"-25 °C to 80 °C","cmc":"0,05 °C"},{"name":"","range":"80 °C to 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 ºC°C to 1100 °C","cmc":"2,5 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-95 °C do -25 °C CMC 0,2 °C\n-25 °C do 80 °C CMC 0,05 °C\n80 °C do 200 °C CMC 0,06 °C\n200 ºC°C do 1100 °C CMC 2,5 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PLP-TE","norm_bases":["PLP-TE"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-95 °C do -25 °C CMC 0,2 °C\n-25 °C do 80 °C CMC 0,05 °C\n80 °C do 200 °C CMC 0,06 °C\n200 ºC°C do 1100 °C CMC 2,5 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PLP-TE Termometry elektryczne (w tym elektroniczne) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-95 °C do -25 °C CMC 0,2 °C\n-25 °C do 80 °C CMC 0,05 °C\n80 °C do 200 °C CMC 0,06 °C\n200 ºC°C do 1100 °C CMC 2,5 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PLP-TE","search_en":"Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) Temperature (electrical thermometry) Internal procedure At permanent location (S) PLP-TE","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-95 °C to -25 °C","cmc":"0,2 °C"},{"name":"","range":"-25 °C to 80 °C","cmc":"0,05 °C"},{"name":"","range":"80 °C to 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 ºC°C to 1100 °C","cmc":"2,5 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) PLP-TE","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-95 °C to -25 °C","cmc":"0,2 °C"},{"name":"","range":"-25 °C to 80 °C","cmc":"0,05 °C"},{"name":"","range":"80 °C to 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 ºC°C to 1100 °C","cmc":"2,5 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) PLP-TE","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-95 °C to -25 °C","cmc":"0,2 °C"},{"name":"","range":"-25 °C to 80 °C","cmc":"0,05 °C"},{"name":"","range":"80 °C to 200 °C","cmc":"0,06 °C"},{"name":"","range":"200 ºC°C to 1100 °C","cmc":"2,5 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PLP-TE","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)"},{"_id":"b7fab4f18348302e9deeded7","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)","test_object_en":"Electrical thermometers (including electronic)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-95 °C do 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C do 1000 °C","cmc":"2,5 °C"}],"parameters_en":[{"name":"","range":"-95 °C to 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C to 1000 °C","cmc":"2,5 °C"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-95 °C do 200 °C CMC 0,2 °C\n200 °C do 1000 °C CMC 2,5 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PLP-TE","norm_bases":["PLP-TE"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-95 °C do 200 °C CMC 0,2 °C\n200 °C do 1000 °C CMC 2,5 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PLP-TE Termometry elektryczne (w tym elektroniczne) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-95 °C do 200 °C CMC 0,2 °C\n200 °C do 1000 °C CMC 2,5 °C\nProcedura wewnetrzna; Poza stala lokalizacja (P) PLP-TE","search_en":"Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry) Internal procedure; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Outside of permanent location (P) PLP-TE","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-95 °C to 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C to 1000 °C","cmc":"2,5 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Außerhalb des festen Standorts (P) PLP-TE","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-95 °C to 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C to 1000 °C","cmc":"2,5 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 校准 — 温度（电测温） 内部程序；固定地点以外 (P) 温度（电测温） 内部程序 固定地点以外 (P) PLP-TE","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"电测温度计（包括电子温度计）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-95 °C to 200 °C","cmc":"0,2 °C"},{"name":"","range":"200 °C to 1000 °C","cmc":"2,5 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Mimo stálé pracoviště (P) Teplota (elektrická termometrie) Vnitřní postup Mimo stálou lokalitu (P) PLP-TE","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)"},{"_id":"9f05ac907e476f57f5d4bdcd","lab_id":"6af5747a0ecd48de0c70624f","country":"PL","accr_number":"AP 115","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (with temperature recording)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-40 °C do 60 °C","cmc":"0,2 °C"},{"name":"","range":"60 °C do 140 °C","cmc":"0,3 °C"}],"parameters_en":[{"name":"","range":"-40 °C to 60 °C","cmc":"0,2 °C"},{"name":"","range":"60 °C to 140 °C","cmc":"0,3 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-40 °C do 60 °C CMC 0,2 °C\n60 °C do 140 °C CMC 0,3 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PLP-RT","norm_bases":["PLP-RT"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-40 °C do 60 °C CMC 0,2 °C\n60 °C do 140 °C CMC 0,3 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PLP-RT Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-40 °C do 60 °C CMC 0,2 °C\n60 °C do 140 °C CMC 0,3 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PLP-RT","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) Temperature (electrical thermometry) Internal procedure At permanent location (S) PLP-RT","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-40 °C to 60 °C","cmc":"0,2 °C"},{"name":"","range":"60 °C to 140 °C","cmc":"0,3 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) PLP-RT","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-40 °C to 60 °C","cmc":"0,2 °C"},{"name":"","range":"60 °C to 140 °C","cmc":"0,3 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) PLP-RT","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-40 °C to 60 °C","cmc":"0,2 °C"},{"name":"","range":"60 °C to 140 °C","cmc":"0,3 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PLP-RT","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"}],"has_pdf":true}