Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki is a calibration laboratory accredited by PCA under number AP 102 (Warszawa, Poland). Its accreditation scope covers 14 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Clamp meters, Multimeters, Analogue and digital current meters. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P).
At a glance
- Accreditation number: PCA AP 102
- Calibration items in scope: 14
- Types of calibrated items: 23
- Calibration principles used: 2
- City: Warszawa, Poland
- Valid until: 29-03-2027
- Accreditation number
- AP 102
- Accreditation body
- PCA
- Address
- ul. Mieczysława Pożaryskiego 28, 04-703 Warszawa
- City
- Warszawa, Poland
- Division
- Research Centre for Electrical Power Apparatus and Electrical Equipment, Testing and Calibration Laboratory for Electrical Equipment
- Valid until
- 29-03-2027
What this laboratory calibrates (23)
- Calibrators — 4 calibration items
- Clamp meters — 4 calibration items
- Multimeters — 4 calibration items
- Analogue and digital current meters — 2 calibration items
- Analogue and digital voltage meters — 2 calibration items
- Fixed resistors — 2 calibration items
- Measuring probes — 2 calibration items
- Power supplies — 2 calibration items
- Shunts — 2 calibration items
- Variable resistors — 2 calibration items
- Analogue and digital resistance meters — 1 calibration item
- Digital resistance meters — 1 calibration item
- Illuminance — 1 calibration item
- Kilovoltmeters, measuring systems, AC voltage dividers — 1 calibration item
- Kilovoltmeters, measuring systems, DC voltage dividers — 1 calibration item
- and 8 more
Calibration principles (2)
- Internal procedure; At permanent location (S) — 12 calibration items
- Internal procedure; At permanent location (S) and outside of it (P) — 2 calibration items
Certificate information
- Issue date
- 21.01.2026
- Issue no.
- 21
- Certificate date
- 11.06.2021
- Accreditation cycle
- 06.03.2023 — 29.03.2027
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (14)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Analogue and digital voltage meters Multimeters Calibrators |
Calibration — DC voltage 0,2 mV to 200 mV · CMC 8·10⁻⁶ · U + 0,2 µV; U – measured value (V) 0,2 V to 2 V · CMC 6·10⁻⁶ · U + 0,7 µV; U – measured value (V) 2 V to 20 V · CMC 7·10⁻⁶ · U + 8 µV; U – measured value (V) 20 V to 200 V · CMC 9·10⁻⁶ · U + 70 µV; U – measured value (V) 200 V to 1000 V · CMC 9·10⁻⁶ · U + 0,9 mV; U – measured value (V) DC voltage |
Internal procedure; At permanent location (S) | PW 03, PW 01; PW 01; PW 02; PW 01, PW 02 based on EURAMET cg-15 v. 3.0 | |
| 2 | Analogue and digital current meters Multimeters Calibrators Clamp meters |
Calibration — DC current 2 µA to 200 µA · CMC 25·10⁻⁶ · I + 0,8 nA; I – measured value (A) 0,2 mA to 2 mA · CMC 2·10⁻⁵ · I + 7 nA; I – measured value (A) 2 mA to 20 mA · CMC 25·10⁻⁶ · I + 70 nA; I – measured value (A) 20 mA to 200 mA · CMC 8·10⁻⁵ · I + 1,3 µA; I – measured value (A) 0,2 A to 2 A · CMC 0,02 % 2 A to 20 A · CMC 0,04 % 20 A to 150 A · CMC 0,1 % DC current |
Internal procedure; At permanent location (S) | PW 03, PW 01; PW 01; PW 02; PW 01; PW 01, PW 02 based on EURAMET cg-15 v. 3.0 | |
| 3 | Clamp meters | Calibration — DC current 20 A to 1000 A · CMC 0,5 % DC current |
Internal procedure; At permanent location (S) | PW 01 based on EURAMET cg-15 v. 3.0 | |
| 4 | Analogue and digital voltage meters Multimeters Calibrators |
Calibration — AC voltage f = 40 Hz to 10 kHz — 0,2 mV to 200 mV · CMC 4·10⁻⁴ · U + 12 µV; U – measured value (V) f = 40 Hz to 10 kHz — 0,2 V to 2 V · CMC 25·10⁻⁵ · U + 40 µV; U – measured value (V) f = 40 Hz to 10 kHz — 2 V to 20 V · CMC 25·10⁻⁵ · U + 0,4 mV; U – measured value (V) f = 40 Hz to 10 kHz — 20 V to 200 V · CMC 2·10⁻⁴ · U + 3,3 mV; U – measured value (V) f = 40 Hz to 10 kHz — 200 V to 1000 V · CMC 25·10⁻⁵ · U + 40 mV; U – measured value (V) f = 10 kHz to 30 kHz — 0,2 mV to 200 mV · CMC 6·10⁻⁴ · U + 15 µV; U – measured value (V) f = 10 kHz to 30 kHz — 0,2 V to 2 V · CMC 4·10⁻⁴ · U + 70 µV; U – measured value (V) f = 10 kHz to 30 kHz — 2 V to 20 V · CMC 45·10⁻⁵ · U + 0,8 mV; U – measured value (V) f = 10 kHz to 30 kHz — 20 V to 200 V · CMC 4·10⁻⁴ · U + 7 mV; U – measured value (V) f = 30 kHz to 100 kHz — 0,2 mV to 200 mV · CMC 14·10⁻⁴ · U + 36 µV; U – measured value (V) f = 30 kHz to 100 kHz — 0,2 V to 2 V · CMC 1·10⁻³ · U + 0,36 mV; U – measured value (V) f = 30 kHz to 100 kHz — 2 V to 20 V · CMC 1·10⁻³ · U + 3,3 mV; U – measured value (V) f = 30 kHz to 100 kHz — 20 V to 200 V · CMC 1·10⁻³ · U + 33 mV; U – measured value (V) AC voltage |
Internal procedure; At permanent location (S) | PW 01, PW 03; PW 01; PW 02; PW 01, PW 02 based on EURAMET cg-15 v. 3.0 | |
| 5 | Analogue and digital current meters Multimeters Calibrators Clamp meters Measuring probes Power supplies |
Calibration — AC current f = 40 Hz to 1 kHz — 20 µA to 200 µA · CMC 6·10⁻⁴ · I + 40 nA; I – measured value (A) f = 40 Hz to 1 kHz — 0,2 mA to 2 mA · CMC 5·10⁻⁴ · I + 0,33 µA; I – measured value (A) f = 40 Hz to 1 kHz — 2 mA to 20 mA · CMC 5·10⁻⁴ · I + 3,3 µA; I – measured value (A) f = 40 Hz to 1 kHz — 20 mA to 200 mA · CMC 5·10⁻⁴ · I + 33 µA; I – measured value (A) f = 40 Hz to 1 kHz — 0,2 A to 2 A · CMC 1·10⁻³ · I + 0,33 mA; I – measured value (A) f = 40 Hz to 1 kHz — 2 A to 20 A · CMC 13·10⁻⁴ · I + 3,3 mA; I – measured value (A) f = 40 Hz to 1 kHz — 20 A to 50 A · CMC 0,2 % f = 1 kHz to 5 kHz — 20 µA to 200 µA · CMC 6·10⁻⁴ · I + 40 nA; I – measured value (A) f = 1 kHz to 5 kHz — 0,2 mA to 2 mA · CMC 5·10⁻⁴ · I + 0,33 µA; I – measured value (A) f = 1 kHz to 5 kHz — 2 mA to 20 mA · CMC 5·10⁻⁴ · I + 3,3 µA; I – measured value (A) f = 1 kHz to 5 kHz — 20 mA to 200 mA · CMC 5·10⁻⁴ · I + 33 µA; I – measured value (A) f = 1 kHz to 5 kHz — 0,2 A to 2 A · CMC 12·10⁻⁴ · I + 1,3 mA; I – measured value (A) AC current |
Internal procedure; At permanent location (S) | PW 01, PW 03; PW 01; PW 02; PW 01; PW 01; PW 02; PW 01, PW 02 based on EURAMET cg-15 v. 3.0 | |
| 6 | Clamp meters Measuring probes Power supplies |
Calibration — AC current f = 50 Hz — 50 A to 1000 A · CMC 0,5 % f = 50 Hz — 50 A to 3000 A · CMC 0,5 % f = 50 Hz — 50 A to 3000 A · CMC 0,5 % AC current |
Internal procedure; At permanent location (S) | PW 01; PW 01; PW 02 | |
| 7 | Analogue and digital resistance meters | Calibration — DC resistance 0,0001 Ω to 0,01 Ω · CMC 0,09 % 0,01 Ω to 0,1 Ω · CMC 0,03 % 0,1 Ω to 2 Ω · CMC 5·10⁻⁵ · R + 10 µΩ; R – measured value (Ω) 2 Ω to 20 Ω · CMC 0,005 % 20 Ω to 200 kΩ · CMC 0,003 % 200 kΩ to 2 MΩ · CMC 0,005 % 2 MΩ to 20 MΩ · CMC 0,006 % 20 MΩ to 410 MΩ · CMC 0,009 % 0,41 GΩ to 10 GΩ · CMC 0,1 % DC resistance |
Internal procedure; At permanent location (S) | PW 03, PW 01; PW 01 based on EURAMET cg-15 v. 3.0 | |
| 8 | Shunts Fixed resistors Variable resistors Resistance calibrators |
Calibration — DC resistance 0,00001 Ω to 0,01 Ω · CMC 0,1 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 2 Ω · CMC 3·10⁻⁵ · R + 7 µΩ; R – measured value (Ω) 2 Ω to 20 Ω · CMC 0,003 % 20 Ω to 200 kΩ · CMC 0,002 % 200 kΩ to 2 MΩ · CMC 0,003 % 2 MΩ to 20 MΩ · CMC 0,004 % 20 MΩ to 410 MΩ · CMC 0,006 % 410 MΩ to 10 GΩ · CMC 0,1 % DC resistance |
Internal procedure; At permanent location (S) | PW 04; PW 04; PW 04; PW 02; PW 02 based on EURAMET cg-15 v. 3.0 | |
| 9 | Fixed resistors Variable resistors Shunts Digital resistance meters Loop impedance meters Power quality (network parameter) meters |
Calibration — AC resistance f = 50 Hz — 0,01 Ω to 1 Ω · CMC 0,15 % f = 50 Hz — 0,001 kΩ to 10 kΩ · CMC 0,08 % AC resistance |
Internal procedure; At permanent location (S) | PW 04; PW 04; PW 04; PW 01; PW 01; PW 01; PW 01 based on EURAMET cg-15 v. 3.0 | |
| 10 | Kilovoltmeters, measuring systems, DC voltage dividers | Calibration — High voltage and current digital — 0,1 kV to 1 kV · CMC 0,02 % digital — 1 kV to 100 kV · CMC 0,05 % analogue — 0,1 kV to 1 kV · CMC 0,3 % analogue — 1 kV to 100 kV · CMC 0,4 % High voltage and current |
Internal procedure; At permanent location (S) and outside of it (P) | PW 08 | |
| 11 | Kilovoltmeters, measuring systems, AC voltage dividers | Calibration — High voltage and current f = 50 Hz; digital — 0,1 kV to 1 kV · CMC 0,2 % f = 50 Hz; digital — 1 kV to 24 kV · CMC 0,25 % f = 50 Hz; digital — 24 kV to 180 kV · CMC 0,5 % f = 50 Hz; analogue — 0,1 kV to 24 kV · CMC 0,4 % f = 50 Hz; analogue — 24 kV to 180 kV · CMC 0,7 % High voltage and current |
Internal procedure; At permanent location (S) and outside of it (P) | PW 08 | |
| 12 | Luminous flux Luminous flux standards |
Calibration — Illuminance 5 lm to 5 klm · CMC 1,65 % 5 klm to 50 klm · CMC 2,0 % Illuminance |
Internal procedure; At permanent location (S) | PW 05 | |
| 13 | Luminous intensity Luminous intensity standards |
Calibration — Illuminance 5 cd to 500 cd · CMC 1,7 % 500 cd to 10 kcd · CMC 2,2 % Illuminance |
Internal procedure; At permanent location (S) | PW 06 | |
| 14 | Illuminance Lux meters |
Calibration — Illuminance 5 lx to 1 klx · CMC 2,5 % 1 klx to 10 klx · CMC 3,0 % Illuminance |
Internal procedure; At permanent location (S) | PW 07 | |
Reference standards (9)
EURAMET cg-15 v. 3.0
PW 01
PW 02
PW 03
PW 04
PW 05
PW 06
PW 07