Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki is a calibration laboratory accredited by PCA under number AP 102 (Warszawa, Poland). Its accreditation scope covers 14 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Clamp meters, Multimeters, Analogue and digital current meters. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P).

At a glance

  • Accreditation number: PCA AP 102
  • Calibration items in scope: 14
  • Types of calibrated items: 23
  • Calibration principles used: 2
  • City: Warszawa, Poland
  • Valid until: 29-03-2027
Accreditation number
AP 102
Accreditation body
PCA
Address
ul. Mieczysława Pożaryskiego 28, 04-703 Warszawa
City
Warszawa, Poland
Division
Research Centre for Electrical Power Apparatus and Electrical Equipment, Testing and Calibration Laboratory for Electrical Equipment
Valid until
29-03-2027

What this laboratory calibrates (23)

Calibration principles (2)

Certificate information

Issue date
21.01.2026
Issue no.
21
Certificate date
11.06.2021
Accreditation cycle
06.03.2023 — 29.03.2027
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (14)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand. In other cases the CMC uncertainty is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Analogue and digital voltage meters
Multimeters
Calibrators
Calibration — DC voltage
0,2 mV to 200 mV · CMC 8·10⁻⁶ · U + 0,2 µV; U – measured value (V) 0,2 V to 2 V · CMC 6·10⁻⁶ · U + 0,7 µV; U – measured value (V) 2 V to 20 V · CMC 7·10⁻⁶ · U + 8 µV; U – measured value (V) 20 V to 200 V · CMC 9·10⁻⁶ · U + 70 µV; U – measured value (V) 200 V to 1000 V · CMC 9·10⁻⁶ · U + 0,9 mV; U – measured value (V)
DC voltage
Internal procedure; At permanent location (S) PW 03, PW 01; PW 01; PW 02; PW 01, PW 02 based on EURAMET cg-15 v. 3.0
2 Analogue and digital current meters
Multimeters
Calibrators
Clamp meters
Calibration — DC current
2 µA to 200 µA · CMC 25·10⁻⁶ · I + 0,8 nA; I – measured value (A) 0,2 mA to 2 mA · CMC 2·10⁻⁵ · I + 7 nA; I – measured value (A) 2 mA to 20 mA · CMC 25·10⁻⁶ · I + 70 nA; I – measured value (A) 20 mA to 200 mA · CMC 8·10⁻⁵ · I + 1,3 µA; I – measured value (A) 0,2 A to 2 A · CMC 0,02 % 2 A to 20 A · CMC 0,04 % 20 A to 150 A · CMC 0,1 %
DC current
Internal procedure; At permanent location (S) PW 03, PW 01; PW 01; PW 02; PW 01; PW 01, PW 02 based on EURAMET cg-15 v. 3.0
3 Clamp meters Calibration — DC current
20 A to 1000 A · CMC 0,5 %
DC current
Internal procedure; At permanent location (S) PW 01 based on EURAMET cg-15 v. 3.0
4 Analogue and digital voltage meters
Multimeters
Calibrators
Calibration — AC voltage
f = 40 Hz to 10 kHz — 0,2 mV to 200 mV · CMC 4·10⁻⁴ · U + 12 µV; U – measured value (V) f = 40 Hz to 10 kHz — 0,2 V to 2 V · CMC 25·10⁻⁵ · U + 40 µV; U – measured value (V) f = 40 Hz to 10 kHz — 2 V to 20 V · CMC 25·10⁻⁵ · U + 0,4 mV; U – measured value (V) f = 40 Hz to 10 kHz — 20 V to 200 V · CMC 2·10⁻⁴ · U + 3,3 mV; U – measured value (V) f = 40 Hz to 10 kHz — 200 V to 1000 V · CMC 25·10⁻⁵ · U + 40 mV; U – measured value (V) f = 10 kHz to 30 kHz — 0,2 mV to 200 mV · CMC 6·10⁻⁴ · U + 15 µV; U – measured value (V) f = 10 kHz to 30 kHz — 0,2 V to 2 V · CMC 4·10⁻⁴ · U + 70 µV; U – measured value (V) f = 10 kHz to 30 kHz — 2 V to 20 V · CMC 45·10⁻⁵ · U + 0,8 mV; U – measured value (V) f = 10 kHz to 30 kHz — 20 V to 200 V · CMC 4·10⁻⁴ · U + 7 mV; U – measured value (V) f = 30 kHz to 100 kHz — 0,2 mV to 200 mV · CMC 14·10⁻⁴ · U + 36 µV; U – measured value (V) f = 30 kHz to 100 kHz — 0,2 V to 2 V · CMC 1·10⁻³ · U + 0,36 mV; U – measured value (V) f = 30 kHz to 100 kHz — 2 V to 20 V · CMC 1·10⁻³ · U + 3,3 mV; U – measured value (V) f = 30 kHz to 100 kHz — 20 V to 200 V · CMC 1·10⁻³ · U + 33 mV; U – measured value (V)
AC voltage
Internal procedure; At permanent location (S) PW 01, PW 03; PW 01; PW 02; PW 01, PW 02 based on EURAMET cg-15 v. 3.0
5 Analogue and digital current meters
Multimeters
Calibrators
Clamp meters
Measuring probes
Power supplies
Calibration — AC current
f = 40 Hz to 1 kHz — 20 µA to 200 µA · CMC 6·10⁻⁴ · I + 40 nA; I – measured value (A) f = 40 Hz to 1 kHz — 0,2 mA to 2 mA · CMC 5·10⁻⁴ · I + 0,33 µA; I – measured value (A) f = 40 Hz to 1 kHz — 2 mA to 20 mA · CMC 5·10⁻⁴ · I + 3,3 µA; I – measured value (A) f = 40 Hz to 1 kHz — 20 mA to 200 mA · CMC 5·10⁻⁴ · I + 33 µA; I – measured value (A) f = 40 Hz to 1 kHz — 0,2 A to 2 A · CMC 1·10⁻³ · I + 0,33 mA; I – measured value (A) f = 40 Hz to 1 kHz — 2 A to 20 A · CMC 13·10⁻⁴ · I + 3,3 mA; I – measured value (A) f = 40 Hz to 1 kHz — 20 A to 50 A · CMC 0,2 % f = 1 kHz to 5 kHz — 20 µA to 200 µA · CMC 6·10⁻⁴ · I + 40 nA; I – measured value (A) f = 1 kHz to 5 kHz — 0,2 mA to 2 mA · CMC 5·10⁻⁴ · I + 0,33 µA; I – measured value (A) f = 1 kHz to 5 kHz — 2 mA to 20 mA · CMC 5·10⁻⁴ · I + 3,3 µA; I – measured value (A) f = 1 kHz to 5 kHz — 20 mA to 200 mA · CMC 5·10⁻⁴ · I + 33 µA; I – measured value (A) f = 1 kHz to 5 kHz — 0,2 A to 2 A · CMC 12·10⁻⁴ · I + 1,3 mA; I – measured value (A)
AC current
Internal procedure; At permanent location (S) PW 01, PW 03; PW 01; PW 02; PW 01; PW 01; PW 02; PW 01, PW 02 based on EURAMET cg-15 v. 3.0
6 Clamp meters
Measuring probes
Power supplies
Calibration — AC current
f = 50 Hz — 50 A to 1000 A · CMC 0,5 % f = 50 Hz — 50 A to 3000 A · CMC 0,5 % f = 50 Hz — 50 A to 3000 A · CMC 0,5 %
AC current
Internal procedure; At permanent location (S) PW 01; PW 01; PW 02
7 Analogue and digital resistance meters Calibration — DC resistance
0,0001 Ω to 0,01 Ω · CMC 0,09 % 0,01 Ω to 0,1 Ω · CMC 0,03 % 0,1 Ω to 2 Ω · CMC 5·10⁻⁵ · R + 10 µΩ; R – measured value (Ω) 2 Ω to 20 Ω · CMC 0,005 % 20 Ω to 200 kΩ · CMC 0,003 % 200 kΩ to 2 MΩ · CMC 0,005 % 2 MΩ to 20 MΩ · CMC 0,006 % 20 MΩ to 410 MΩ · CMC 0,009 % 0,41 GΩ to 10 GΩ · CMC 0,1 %
DC resistance
Internal procedure; At permanent location (S) PW 03, PW 01; PW 01 based on EURAMET cg-15 v. 3.0
8 Shunts
Fixed resistors
Variable resistors
Resistance calibrators
Calibration — DC resistance
0,00001 Ω to 0,01 Ω · CMC 0,1 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 2 Ω · CMC 3·10⁻⁵ · R + 7 µΩ; R – measured value (Ω) 2 Ω to 20 Ω · CMC 0,003 % 20 Ω to 200 kΩ · CMC 0,002 % 200 kΩ to 2 MΩ · CMC 0,003 % 2 MΩ to 20 MΩ · CMC 0,004 % 20 MΩ to 410 MΩ · CMC 0,006 % 410 MΩ to 10 GΩ · CMC 0,1 %
DC resistance
Internal procedure; At permanent location (S) PW 04; PW 04; PW 04; PW 02; PW 02 based on EURAMET cg-15 v. 3.0
9 Fixed resistors
Variable resistors
Shunts
Digital resistance meters
Loop impedance meters
Power quality (network parameter) meters
Calibration — AC resistance
f = 50 Hz — 0,01 Ω to 1 Ω · CMC 0,15 % f = 50 Hz — 0,001 kΩ to 10 kΩ · CMC 0,08 %
AC resistance
Internal procedure; At permanent location (S) PW 04; PW 04; PW 04; PW 01; PW 01; PW 01; PW 01 based on EURAMET cg-15 v. 3.0
10 Kilovoltmeters, measuring systems, DC voltage dividers Calibration — High voltage and current
digital — 0,1 kV to 1 kV · CMC 0,02 % digital — 1 kV to 100 kV · CMC 0,05 % analogue — 0,1 kV to 1 kV · CMC 0,3 % analogue — 1 kV to 100 kV · CMC 0,4 %
High voltage and current
Internal procedure; At permanent location (S) and outside of it (P) PW 08
11 Kilovoltmeters, measuring systems, AC voltage dividers Calibration — High voltage and current
f = 50 Hz; digital — 0,1 kV to 1 kV · CMC 0,2 % f = 50 Hz; digital — 1 kV to 24 kV · CMC 0,25 % f = 50 Hz; digital — 24 kV to 180 kV · CMC 0,5 % f = 50 Hz; analogue — 0,1 kV to 24 kV · CMC 0,4 % f = 50 Hz; analogue — 24 kV to 180 kV · CMC 0,7 %
High voltage and current
Internal procedure; At permanent location (S) and outside of it (P) PW 08
12 Luminous flux
Luminous flux standards
Calibration — Illuminance
5 lm to 5 klm · CMC 1,65 % 5 klm to 50 klm · CMC 2,0 %
Illuminance
Internal procedure; At permanent location (S) PW 05
13 Luminous intensity
Luminous intensity standards
Calibration — Illuminance
5 cd to 500 cd · CMC 1,7 % 500 cd to 10 kcd · CMC 2,2 %
Illuminance
Internal procedure; At permanent location (S) PW 06
14 Illuminance
Lux meters
Calibration — Illuminance
5 lx to 1 klx · CMC 2,5 % 1 klx to 10 klx · CMC 3,0 %
Illuminance
Internal procedure; At permanent location (S) PW 07

Reference standards (9)

EURAMET cg-15 v. 3.0
PW 01
PW 02
PW 03
PW 04
PW 05
PW 06
PW 07
PW 08