🇵🇱 Centrum Badań i Dozoru Sp. z o.o. PL

PCA AP 096 • Mysłowice, Poland • 16 calibration items

Metrology & calibration

Centrum Badań i Dozoru Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 096 (Mysłowice, Poland). Its accreditation scope covers 16 calibration items in the following areas: Metrology & calibration. Calibrated items include: Data acquisition cards, Electrical safety testers, Multimeters, Calibrators. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S) and ou…, Internal procedure; Direct and indirect method; At permanent locati…, Internal procedure; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 096
  • Calibration items in scope: 16
  • Types of calibrated items: 28
  • Calibration principles used: 3
  • City: Mysłowice, Poland
  • Valid until: 27-06-2030
Accreditation number
AP 096
Accreditation body
PCA
Address
ul. Fabryczna 20, 41-404 Mysłowice
City
Mysłowice, Poland
Division
Measurement Laboratory of the Measurement and Automation Centre
Valid until
27-06-2030

What this laboratory calibrates (28)

Calibration principles (3)

Certificate information

Issue date
21.05.2026
Issue no.
19
Certificate date
25.05.2022
Accreditation cycle
21.05.2026 — 27.06.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (16)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Power analysers
Calibrators
Data acquisition cards
Analogue voltmeters
Digital voltmeters
Power quality meters
Multimeters
Power supplies
Voltage sources
Calibration — DC voltage
0 mV to 4 mV · CMC 0,23 µV 4 mV to 20 mV · CMC 0,0053 % 20 mV to 200 mV · CMC 0,0018 % 0,2 V to 20 V · CMC 0,0005 % 20 V to 1000 V · CMC 0,0008 %
DC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedures PP-01 PP-02 PP-06
2 Power analysers
Calibrators
Data acquisition cards
Analogue ammeters
Digital ammeters
Power quality meters
Multimeters
Power supplies
DC current sources
Calibration — DC current
0 µA to 4 µA · CMC 0,91 nA 4 µA to 10 µA · CMC 0,0090 % 0,01 mA to 10 mA · CMC 0,002 % 10 mA to 100 mA · CMC 0,006 %
DC current
Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) Internal procedures PP-01 PP-02 PP-06
3 Power analysers
Data acquisition cards
Analogue ammeters
Digital ammeters
Power quality meters
Multimeters
Electrical safety testers
Calibration — DC current
0,1 A to 2 A · CMC 0,011 % 2 A to 20 A · CMC 0,03 %
DC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedures PP-01 PP-02
4 Calibrators
Power supplies
Calibration — DC current
0,1 A to 2 A · CMC 0,023 % 2 A to 10 A · CMC 0,03 % 10 A to 30 A · CMC 0,085%
DC current
Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) Internal procedure PP-06
5 Power analysers
Data acquisition cards
Analogue voltmeters
Digital voltmeters
Power quality meters
Multimeters
Electrical safety testers
Calibration — AC voltage
10 Hz to 40 Hz — 0,1 mV to 1 mV · CMC 0,4 % 10 Hz to 40 Hz — 1 mV to 10 mV · CMC 0,075 % 10 Hz to 40 Hz — 0,01 V to 100 V · CMC 0,011 % 10 Hz to 40 Hz — 100 V to 1000 V · CMC 0,022 % 40 Hz to 2 kHz — 0,1 mV to 1 mV · CMC 0,24 % 40 Hz to 2 kHz — 1 mV to 10 mV · CMC 0,055 % 40 Hz to 2 kHz — 10 mV to 100 mV · CMC 0,011 % 40 Hz to 2 kHz — 0,1 V to 10 V · CMC 0,006 % 40 Hz to 2 kHz — 10 V to 100 V · CMC 0,008 % 40 Hz to 2 kHz — 100 V to 1000 V · CMC 0,014 % 2 kHz to 20 kHz — 0,1 mV to 1 mV · CMC 0,26 % 2 kHz to 20 kHz — 1 mV to 10 mV · CMC 0,060 % 2 kHz to 20 kHz — 10 mV to 100 mV · CMC 0,015 % 2 kHz to 20 kHz — 0,1 V to 10 V · CMC 0,006 % 2 kHz to 20 kHz — 10 V to 100 V · CMC 0,008 % 2 kHz to 20 kHz — 100 V to 700 V · CMC 0,039 % 2 kHz to 10 kHz — 700 V to 1000 V · CMC 0,018 % 20 kHz to 50 kHz — 0,1 mV to 1 mV · CMC 0,5 % 20 kHz to 50 kHz — 1 mV to 10 mV · CMC 0,072 % 20 kHz to 50 kHz — 10 mV to 100 mV · CMC 0,023 % 20 kHz to 50 kHz — 0,1 V to 1 V · CMC 0,014 % 20 kHz to 50 kHz — 1 V to 10 V · CMC 0,010 % 20 kHz to 50 kHz — 10 V to 100 V · CMC 0,011 % 20 kHz to 50 kHz — 100 V to 200 V · CMC 0,16 % 50 kHz to 100 kHz — 0,1 mV to 1 mV · CMC 0,7 % 50 kHz to 100 kHz — 1 mV to 10 mV · CMC 0,12 % 50 kHz to 100 kHz — 10 mV to 100 mV · CMC 0,08 % 50 kHz to 100 kHz — 0,1 V to 10 V · CMC 0,013 % 50 kHz to 100 kHz — 10 V to 100 V · CMC 0,021 % 50 kHz to 100 kHz — 100 V to 200 V · CMC 0,16 % 100 kHz to 300 kHz — 0,1 mV to 1 mV · CMC 1,3 % 100 kHz to 300 kHz — 1 mV to 10 mV · CMC 0,25 % 100 kHz to 300 kHz — 10 mV to 100 mV · CMC 0,15 % 100 kHz to 300 kHz — 0,1 V to 10 V · CMC 0,045 % 300 kHz to 1 MHz — 1 mV to 10 mV · CMC 0,55 % 300 kHz to 1 MHz — 10 mV to 100 mV · CMC 0,37 % 300 kHz to 1 MHz — 0,1 V to 10 V · CMC 0,22 %
AC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedures PP-01 PP-02
6 Generators
Calibrators
Data acquisition cards
Power supplies
Calibration — AC voltage
10 Hz to 40 Hz — 0,1 mV to 1 mV · CMC 0,4 % 10 Hz to 40 Hz — 1 mV to 10 mV · CMC 0,075 % 10 Hz to 40 Hz — 0,01 V to 100 V · CMC 0,011 % 10 Hz to 40 Hz — 100 V to 1000 V · CMC 0,022 % 40 Hz to 2 kHz — 0,1 mV to 1 mV · CMC 0,24 % 40 Hz to 2 kHz — 1 mV to 10 mV · CMC 0,055 % 40 Hz to 2 kHz — 0,01 V to 10 V · CMC 0,011 % 40 Hz to 2 kHz — 10 V to 100 V · CMC 0,012 % 40 Hz to 2 kHz — 100 V to 1000 V · CMC 0,02 % 2 kHz to 10 kHz — 0,1 mV to 1 mV · CMC 0,27 % 2 kHz to 10 kHz — 1 mV to 10 mV · CMC 0,070 % 2 kHz to 10 kHz — 0,01 V to 700 V · CMC 0,019 % 2 kHz to 10 kHz — 700 V to 1000 V · CMC 0,018 % 10 kHz to 20 kHz — 0,1 mV to 1 mV · CMC 0,27 % 10 kHz to 20 kHz — 1 mV to 10 mV · CMC 0,070 % 10 kHz to 20 kHz — 10 mV to 100 mV · CMC 0,034 % 10 kHz to 20 kHz — 0,1 V to 10 V · CMC 0,028 % 10 kHz to 20 kHz — 10 V to 100 V · CMC 0,030 % 10 kHz to 20 kHz — 100 V to 700 V · CMC 0,039 % 20 kHz to 50 kHz — 0,1 mV to 1 mV · CMC 0,6 % 20 kHz to 50 kHz — 1 mV to 10 mV · CMC 0,16 % 20 kHz to 50 kHz — 10 mV to 100 mV · CMC 0,071 % 20 kHz to 50 kHz — 0,1 V to 10 V · CMC 0,039 % 20 kHz to 50 kHz — 10 V to 100 V · CMC 0,046 % 20 kHz to 50 kHz — 100 V to 200 V · CMC 0,16 % 50 kHz to 100 kHz — 0,1 mV to 1 mV · CMC 0,7 % 50 kHz to 100 kHz — 1 mV to 10 mV · CMC 0,46 % 50 kHz to 100 kHz — 10 mV to 100 mV · CMC 0,091 % 50 kHz to 100 kHz — 0,1 V to 10 V · CMC 0,091 % 50 kHz to 100 kHz — 10 V to 100 V · CMC 0,091% 50 kHz to 100 kHz — 100 V to 200 V · CMC 0,16 % 100 kHz to 300 kHz — 0,1 mV to 1 mV · CMC 2,1 % 100 kHz to 300 kHz — 1 mV to 10 mV · CMC 1,6 % 100 kHz to 300 kHz — 0,01 V to 10 V · CMC 0,4 % 300 kHz to 1 MHz — 1 mV to 10 mV · CMC 3,1 % 300 kHz to 1 MHz — 10 mV to 100 mV · CMC 1,7 % 300 kHz to 1 MHz — 0,1 V to 10 V · CMC 1,8 %
AC voltage
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP-06
7 Power analysers
Data acquisition cards
Analogue ammeters
Digital ammeters
Power quality meters
Leakage current meters
Multimeters
Electrical safety testers
Calibration — AC current
10 Hz to 50 Hz — 0,01 mA to 100 mA · CMC 0,05 % 10 Hz to 50 Hz — 0,1 A to 2 A · CMC 0,06 % 10 Hz to 50 Hz — 2 A to 10 A · CMC 0,13 % 50 Hz to 1 kHz — 10 µA to 100 µA · CMC 0,030 % 50 Hz to 1 kHz — 0,1 mA to 100 mA · CMC 0,021 % 50 Hz to 1 kHz — 0,1 A to 2 A · CMC 0,039 % 50 Hz to 1 kHz — 2 A to 10 A · CMC 0,13 % 50 Hz to 1 kHz — 10 A to 30 A · CMC 0,22 % 1 kHz to 5 kHz — 0,01 mA to 100 mA · CMC 0,050 % 1 kHz to 5 kHz — 0,1 A to 2 A · CMC 0,072 % 5 kHz to 10 kHz — 0,01 mA to 100) mA · CMC 0,14 % 5 kHz to 10 kHz — 0,1 A to 1 A · CMC 0,11 %
AC current
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedures PP-01 PP-02
8 Calibrators
Power supplies
Calibration — AC current
10 Hz to 50 Hz — 0,01 mA to 100 mA · CMC 0,05 % 10 Hz to 50 Hz — 0,1 A to 2 A · CMC 0,06 % 10 Hz to 50 Hz — 2 A to 10 A · CMC 0,13 % 50 Hz to 1 kHz — 0,01 mA to 100 mA · CMC 0,05 % 50 Hz to 1 kHz — 0,1 A to 2 A · CMC 0,06 % 50 Hz to 1 kHz — 2 A to 10 A · CMC 0,13 % 50 Hz to 1 kHz — 10 A to 30 A · CMC 0,22 % 1 kHz to 5 kHz — 0,01 mA to 100 mA · CMC 0,085 % 1 kHz to 5 kHz — 0,1 A to 2 A · CMC 0,1 % 5 kHz to 10 kHz — 0,01 mA to 100 mA · CMC 0,09 % 5 kHz to 10 kHz — 0,1 A to 1 A · CMC 0,11 %
AC current
Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) Internal procedure PP-06
9 Resistance calibrators
Data acquisition cards
Analogue ohmmeters
Digital ohmmeters
Insulation resistance meters
Earth resistance meters
Multimeters
Fixed resistors
Variable resistors
Electrical safety testers
Resistance standards
Calibration — DC resistance
0 Ω to 0,4 Ω · CMC 8,4 µΩ 0,4 Ω to 1 Ω · CMC 0,0025 % 1 Ω to 10 Ω · CMC 0,0014 % 10 Ω to 100 Ω · CMC 0,0012 % 0,1 kΩ to 100 kΩ · CMC 0,0012 % 0,1 MΩ to 1 MΩ · CMC 0,0015 % 1 MΩ to 10 MΩ · CMC 0,0025 % 10 MΩ to 100 MΩ · CMC 0,013 % 0,1 GΩ to 1 GΩ · CMC 0,05 % 1 GΩ to 10 GΩ · CMC 0,25 %
DC resistance
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedures PP-03 PP-05
10 Analogue ohmmeters
Digital ohmmeters
Insulation resistance meters
Electrical safety testers
Calibration — DC resistance
0,1 GΩ to 1 GΩ · CMC 0,12 % 1 GΩ to 10 GΩ · CMC 0,27 % 10 GΩ to 100 GΩ · CMC 0,58 % 100 GΩ to 1000 GΩ · CMC 1,3 %
DC resistance
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP-03
11 Electrical safety testers
Breakdown testers
Voltage sources
High-voltage measuring systems
Calibration — High voltage and current
DC — 1 kV to 10 kV · CMC 0,05 % DC — 10 kV to 50 kV · CMC 2%
High voltage and current
Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) Internal procedure PP-07
12 Electrical safety testers
Breakdown testers
Voltage sources
High-voltage measuring systems
Calibration — High voltage and current
50 Hz to 60 Hz — 1 kV to 10 kV · CMC 0,15 % 50 Hz — 10 kV to 100 kV · CMC 2%
High voltage and current
Internal procedure; Direct and indirect method; At permanent location (S) and outside of it (P) Internal procedure PP-07
13 Power analysers
Data acquisition cards
Digital frequency meters
Power quality meters
Multimeters
Calibration — Frequency
10 Hz to 1 MHz · CMC 0,003 %
Frequency
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP-04
14 Generators
Calibrators
Calibration — Frequency
1 Hz to 40 Hz · CMC 0,0005 % 40 Hz to 10 MHz · CMC 0,0002 %
Frequency
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure PP-06
15 Vernier calipers Calibration — Length
0 mm to 150 mm · CMC 0,015 mm 0 mm to 300 mm · CMC 0,018 mm
Length
Internal procedure; At permanent location (S) Internal procedure PP-G-01
16 External micrometers Calibration — Length
0 mm to 25 mm · CMC 1,5 µm 25 mm to 50 mm · CMC 1,9 µm 50 mm to 75 mm · CMC 2,4 µm 75 mm to 100 mm · CMC 3,1 µm 100 mm to 125 mm · CMC 3,7 µm 125 mm to 150 mm · CMC 4,3 µm 150 mm to 175 mm · CMC 5,0 µm 175 mm to 200 mm · CMC 5,6 µm 200 mm do 225 mm · CMC 6,3 µm 225 mm do 250 mm · CMC 6,9 µm 250 mm do 275 mm · CMC 7,6 µm 275 mm do 300 mm · CMC 8,2 µm
Length
Internal procedure; At permanent location (S) Internal procedure PP-G-02

Reference standards (9)

PP-01
PP-02
PP-03
PP-04
PP-05
PP-06
PP-07
PP-G-01
PP-G-02